RECTANGULAR TANK

CONCRETE MIX STEEL GRADE Assume height CAPACITY Area to be provided Provide length (L) breadth Provide breadth(B) L /B

15 415 3.50 84.00 24.00 6.00 4.00 4.00 1.50 less than 2 cum

walls of tank are to be design continious slab Considering the long wall h B. M @ Centre B. M @ corner H/4 56.25 75.00 0.875 Kn-m Kn-m 1.00

Considering the short wall B. M @ Centre B. M @ corner 25.00 33.33 Kn-m Kn-m

Wall design for cantilever B.m To find pull on long wall To find pull on short wall 5.83 50.00 75.00 Kn-m Kn Kn

design section using M20 & m.s bars Q d Provide over all depth Effective depth 1.33 237.22 265.00 240.00 mm mm mm

DESIGN OF REINFORCEMENT 1 LONG WALL net moment Ast1 steel for tension Ast2 Total ast dia of bar Spacing 434.78 3402.60 20.00 92.3 sqm sqm mm mm Corner walls are to be design for B.M & Tension 69.63 2967.82 Kn-m sqm

AT MIDDLE OF LONG SPAN Ast1 1995.10 Ast2 Total ast dia of bar Spacing 400.00 2395.10 16.00 83.90

sqm sqm sqm mm mm

SHORT WALL Ast1 Ast2 Total ast

AT CORNER 1077.19 652.174 1729.36 sqm sqm mm

dia of bar Spacing

16.00 116.20

mm

SHORT WALL Ast1 Ast2 Total ast dia of bar Spacing

AT CENTRE 664.216 652.174 1316.39 10.00 59.63

VERTICAL REINFORCEMNT Ast1 248.65

MIN RE dia of bar Spacing

670.45 12.00 168.603