DESCRIPTION
REQUIREMENTS
PULSAFEEDER
SPX
MILTON RAY
PUMP TYPE NUMBER OF PUMPS REQUIRED TYPE OF DRIVER: ELECTRIC MOTOR DUTY 1 GENERAL MAINS SUPPLY FREQUENCY AMBIENT TEMPARATURE C AREA CLASIFICATION
METERING OPERATING 1 INSTALLED SPARE 1 OPERATING 1 INSTALLED SPARE 1 CONTINUOUS NOT AVAILABLE IN DATA SHEET 36 NOT AVAILABLE IN DATA SHEET
COMPLIED 1 1 NOT SPECIFIED 50Hz NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED COMPLIED COMPLIED COMPLIED NOT SPECIFIED COMPLIED NOT SPECIFIED 3.5 NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED COMPLIED NOT SPECIFIED COMPLIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
COMPLIED 1 1 NOT SPECIFIED 50Hz 0-50 HAZARDOUS ZONE 2 IIB T3 COMPLIED COMPLIED COMPLIED NOT SPECIFIED COMPLIED COMPLIED 2.3 56 4.0-58 0.99 COMPLIED 0.2 NOT SPECIFIED COMPLIED COMPLIED N/A NBR DP2-DOUBLE DIAPHRAGM 16 28.3 92.3 127 62
COMPLIED 2 2 NOT SPECIFIED 50Hz 58 HAZARDOUS ZONE 1 IIB T4 COMPLIED COMPLIED COMPLIED 2.79 COMPLIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED 200cp NOT SPECIFIED COMPLIED NOT SPECIFIED COMPLIED NOT SPECIFIED NOT SPECIFIED HYDRAULICALLY ACTUATED PTFE DOUBLE DAIPHRAGM 22.2 27.9 NOT SPECIFIED 36 52.9
ZONE/EXPL.GROUP/TEMP. CLASS NOT AVAILABLE IN DATA SHEET OPERATING CASE LIQUID CAPACITY@ P.T. l/hr Minimum /Normal Required l/hr CORROSION INHIBITOR CORROSION INHIBITOR (NOTE 1) 23.7 1 / 2.4 46 0 NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET 25 @ 20C 0.2 MANUAL ADJUSTMENT OF STROKE LENGTH MANUAL 316SS NO NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET l/h NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET
PROCESS
DISCHARGE PRESSURE:Required bar g SUCTION PRESSURE: Normal bar g NPSH CALCULATED mwc SET PRESSURE OF EXTERNAL SAFTY VALVE: bar FLUID TEMPERATURE:(min/max:C) FLUID DENSITY : g/cm FLUID VISCOSITY Cp FLUID VAPOR PRESSURE: bar a FLOW CONTROLLED BY METHOD OF STARTING SPARE PUMP MATERIAL RECOMMENDED PUMP JACKET REQUIRED PUMP SEALING REQUIREMENT TYPE O PUMPHEAD PLUNGER DIAMETER: mm FLOW RATE VOLUMETRIC EFFICIENCY (DESIGN) % STROKING SPEED S/M 1/min SET PRESSURE OF INTERNAL RELIEF VALVE: barg TEST PRESSURE,HYDROSTATIC bar g DIAPHRAGM CONDITION INDICATION TYPE-SUCTION
PUMPHEAD
NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET mm NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET
NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
69 PRESSURE SWITCH DOUBLE BALL 0 DOUBLE BALL 0 FLANGE ANSI B1.20.1 / 1/2" / 600lbs / RE STRAIGHT FLANGE ANSI B1.20.1 / 1/2" / 600lbs / RE STRAIGHT SS316L PTFE SS316L SS316L B+L STANDARD NBR H1 / 44 / 2 20 N/A MANUAL 0-20mm
NOT SPECIFIED PRESSURE GAUGE NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED 1/2" RF/SF B16.5 / 1/2" / RF/SF HORIZONTAL 1/2" RF/SF B16.5 / 1/2" / RF/SF VERTICAL SS316L SS316L SS316L SS316L SS316L SS316L NOT SPECIFIED 36 NOT SPECIFIED MANUAL NOT SPECIFIED
PUMPHEAD VALVES
VALVE OPENING PRESSURE bar g TYPE-DISCARGE VALVE OPENING PRESSURE bar g TYPE-SUCTION STANDARD / DN / PN / FACING
PUMPHEAD CONNECTIONS
VLAVE HOUSING / SEAT / BODY PROCESS CONNECTION PLUNGER PLUNGER PACKING TYPE / REDUCTION RATIO STROKE LENGTH MAX.
POWER KW MAINS Ph / V / Hz NOMINAL SPEED TYPE OF PROTECTION 8 MOTOR INGRESS PROTECTION MOUNTING ARRANGEMENT FRAME SIZE FLANGE OD mm MOUNTING SIDE ON GEAR NOTES:
NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET 1/min AVAILABLE IN DATA SHEET NOT NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET NOT AVAILABLE IN DATA SHEET
NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
0.55 3/415/50 1000 NOT SPECIFIED NOT SPECIFIED FLANGE ADAPTOR NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
1. COMBINATION OF AMINE DERIVATIVES AND QAUTS BASED IN AQUEOUS SOLVENTS WITH DETERGENT PROPERTIES. 2. PROCESS PARAMETERS INCLUDING TEMPERATURE, PRESSURE RANGES, SERVICE AND RELATED PROPERTIES TO BE COMPLIED BY VENDOR. 3. DAMPNER DETAILS AND CHARGING HOSE INSTRUCTIONS ARE NOT REVIEWED AS RELEVANT DATASHEET IS NOT AVAILABLE WITH US. 4. MOST OF THE DATA IN PILSAFEEDER AND MILTON ROY CATALOGS / DATA SHEET IS MISSING. 5. SPX's REVISED OFFER IS IN LINE WITH REQUIREMENTS IN DATA SHEET, HOWEVER AS SPECIFIED IN NOTE-2 ,VENDOR SHALL COMPLY TO ALL OPERATING PARAMETRS.