Você está na página 1de 15

7.02324.21.

00
© KROHNE 04/2001 C 31 0000 02 E

GR/PRINTO

Electromagnetic
Flowmeters

Variable area flowmeters


Vortex flowmeters
Flow controllers
Electromagnetic flowmeters
Ultrasonic flowmeters
Mass flowmeters
Level measuring instruments
Communications engineering
Engineering systems & solutions
Electromagnetic
flowmeters

The principle of electromagnetic flowmetering has various special


advantages over other methods of measurement:

● Measurement largely independent of pressure,


density,
Electromagnetic flowmeters from KROHNE temperature,
are designed to measure the volumetric viscosity
flowrate of liquids and flow profile
(with and without solids contents),
pulps, pastes and slurries in practically all ● Short inlet and outlet runs
industrial sectors. ● Unimpeded tube cross-section
The only requirement is that the process
product should have a defined minimum ● No additional pressure drop
electrical conductivity. ● No moving parts

● Any installation position

● Turn-down ratio 100:1

KROHNE is of course your competent


partner in other sectors of instrumentation
and control.

Ultra-modern electronic equipment and


state-of-the-art production processes,
combined with an efficient quality
management system,
ensure consistently high precision
and quality in variable-area flowmeters,
CORIMASS mass flow meters,
level measuring devices, as well as
engineering solutions & systems
and communications engineering.

2
Application

Background
KROHNE electromagnetic flowmeters are to be found
in many industrial sectors and applications.
Just a small selection:

Wastewater
● Chemical industry

Water
● Water and wastewater

● Hydraulic transport,
liquid products with up to 50% solids content

corrosive and measurement Beverage,


hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive,
● Paper and woodpulp production
● Pharmaceutical

● Food and beverages

Non-contact
● Filling and dispensing processes

● Highly abrasive slurries

● High-pressure industrial processes

● Partially filled pipelines

Food,
and many, many other applications in other industries

High Pressure
and special
and Remote
Integral
FIT and FORGET !

Signal converter
All electromagnetic flowmeters are delivered ready for operation.
Install the flowmeter in the pipeline,
make the electrical connection, that's it.

Remote

Calibration /
Measuring
Principle
Sizing / instal-
lation guides
Ordering
guide

Background 3.1 3
Always one step ahead with KROHNE

This highly accurate measurement technology is available with integrally


or remote mounted converter, some with measuring errors of less than
0.2% of the measured value.
The primary head is installed in the pipeline, while the signal converter
for signal processing is remote mounted in a field housing or 19"
plug-in unit.
In the integral system, the signal converter is mounted in a housing
with high protection category directly on the primary head.

With meter sizes of DN 2.5 - 3000 / 1/10" - 120",


measurements can be carried out from 2 l/h to 300 000 m3/h
and more.
Most of the devices are approved for use in hazardous locations.
Various materials are available for the measuring tube,
liner and electrodes of the flowmeters for most applications.

4 Background 3.1
Production and calibration

Background
All electromagnetic flowmeters from KROHNE meet the
requirements of CE directives and EMC guidelines.
Fabrication and production shops are certified to ISO 9001.

Wastewater
Water
corrosive and measurement Beverage,
hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive, Non-contact Food,


At KROHNE, all electromagnetic flowmeters are calibrated

High Pressure
and special
by direct comparison of volumes,
the most accurate calibration method of all.
The KROHNE calibration rigs are the world's biggest
and most accurate, and are certified to EN 45 001.
Measurement uncertainty is less than 0.03% of the

and Remote
measured value for meter sizes up to DN 3000 / 120" and above.

Integral
Signal converter
Device selection

The following tables will help you to find the right device for your partic-
ular application.

Remote
Pages 6 and 7 comprise the various flowmeters (primary heads) and
pages 8 and 9 the associated signal converters.

The easiest way is to note down the operating data relevant to your
Calibration /
Measuring
application. Each additional feature will narrow down the number of
Principle

suitable devices. For example:


Sizing / instal-

Feature Choice of device


lation guides

(see table for No.)


● Meter size DN 150 or 6" 1, 2, 3, 4, 10, 11, 12
● Operating temperature = 60°C / 140°F 1, 2, 3, 4, 10, 11, 12
● Operating pressure = 40 bar /psig 1, 4, 11, 12
Ordering

● Process product = a chemical 4, 12


guide

● Measuring error ≤ 0.3% of measured value 4, 12


● Version = K (compact system) 4
Primary head = No. 4 ALTOFLUX IFS 4000 K
Signal converter IFC 020 K or IFC 090 K

Signal converter selected from pages 8 and 9 by the same method.

Background 3.1 5
Electromagnetic flowmeters Altoflux M 900 F
Altoflux IFS 4005 F
Selection guide Altoflux IFS 2005 F
4)

4)
Tidalflux IFM 4110 PF
Batchflux - Batchcontrol
Capaflux IFM 5080 K-CAP
Variflux IFS 6000 K, F, E
Profiflux IFS 5000 K, F, E
Altoflux IFS 4000 K, F, E
Altoflux IFS 2000 F, E
Ecoflux IFS 1000 K, F, E
Aquaflux K, F, E

1 2 3 4 5 6 7 8 9 10 11 12

Sizes from _ to _ / connections


DN 2.5 1/ "
10
DN 10 3/ "
8
DN 25 1"
DN 40 11/2"
DN 50 2"
DN 80 3"
DN 100 4"
DN 125 5"
DN 150 6"
DN 200 8"
DN 250 10"
DN 300 12"
DN 1800 72"
DN 3000 120"

flange connections
flangeless design
sanitary connections

Full-scale range from _ to _


6 l/h 0.02 US Gal/min
85 l/h 0.30 US Gal/min
530 l/h 2.30 US Gal/min
19 m3/h 90 US Gal/min
35 m3/h 150 US Gal/min
50 m3/h 220 US Gal/min
220 m3/h 950 US Gal/min
340 m3/h 1 500 US Gal/min
760 m3/h 3 360 US Gal/min
1 350 m3/h 9 000 US Gal/min
2 100 m3/h 10 000 US Gal/min
3 050 m3/h 14 100 US Gal/min
109 000 m3/h 507 000 US Gal/min
305 000 m3/h 1 400 000 US Gal/min

Application fields (e.g.)


chemicals
water and sewage
partially filled pipes
pharmaceutical, sanitary
batching (1-10 s)
very abrasive slurries
high pressure
general purpose

4) 4)

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit
1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” 3) see Data sheet “TIDAFLUX IFM4110PF” 4) see Data sheet “ALTOFLUX IFS 2000 or 4000”

6 Background 3.1
Electromagnetic flowmeters Altoflux M 900 F

Background
Altoflux IFS 4005 F
Selection guide Altoflux IFS 2005 F
Tidalflux IFM 4110 PF
Batchflux - Batchcontrol

Wastewater
Capaflux IFM 5080 K-CAP

Water
Variflux IFS 6000 K, F, E
Profiflux IFS 5000 K, F, E
Altoflux IFS 4000 K, F, E

corrosive and measurement Beverage,


Altoflux IFS 2000 F, E

hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive,
Ecoflux IFS 1000 K, F, E
Aquaflux K, F, E

1 2 3 4 5 6 7 8 9 10 11 12

Non-contact
Product temperature range
>+180°C >+356°F on request
+180°C +356°F max. remote
+140°C +284°F max. compact
+120°C +248°F
+100°C +212°F

Food,
+ 90°C +194°F
+ 60°C +140°F
0°C + 32°F
- 5°C + 23°F

High Pressure
- 20°C - 4°F

and special
- 25°C - 13°F
- 60°C - 75°F min.

Operation pressure
≤ 1 500 bar ≤20 000 psig on request

and Remote
≤ 40bar ≤ 580psig

Integral
≤ 16 bar ≤ 230 psig

Signal converter
≤ 10bar ≤ 150psig

Elecrical conductivity
≥ 0.05 µS/cm capacitive signal pickup

Remote
≥ 5.00 µS/cm
≥ 20.00 µS/cm water
≥ 50.00 µS/cm

Approvals
Calibration /
Measuring
Principle

EEx versions
FM Factory Mutual
3A
FML Weihenstephan
Sizing / instal-
lation guides

Combined with _ _ _ _
Signal converter Error
IFC 010 K, F ≤ ± 0.5 % of MV
IFC 020 K ≤ ± 0.3 % of MV
IFC 020 F, E ≤ ± 0.3 % of MV
IFC 090 K ≤ ± 0.3 % of MV
IFC 090 F ≤ ± 0.3 % of MV
Ordering

IFC 110 F ≤ ± 0.3 (0.2) % of MV


guide

IFC 210 E ≤ ± 0.3 (0.2) % of MV


SC 150 F ≤ ± 0.4 % of MV
IFC 012 K / 014 K ≤ ± 0.4/0.2/0.1 % of MV 1)

IFC 090 K-CAP ≤ ± 0.5 % of MV 2)

IFC 110 PF ≤ ± 1.0 % of MV 3)


(MV=Measured Volume)

4) 4)

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit
1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” 3) see Data sheet “TIDAFLUX IFM4110PF” 4) see Data sheet “ALTOFLUX IFS 2000 or 4000”

Background 3.1 7
Signal converters SC 150 F
for electromagnetic flowmeters IFC 012 K / 014 K
IFC 210 E
Selection guide
IFC 110 F + IFC 110 PF
IFC 090 K, F + IFC 090 K–CAP
IFC 020 K, F, E
IFC 010 K, F

1 2 3 4 5 6 7

Standard equipment and approvals


outputs- / inputs
forward / reverse flow
low-flow cutoff
limit contact
loop test fiunction
galvanic isolation
overvoltage protection
automatic range change
external totalizer reset
external range selector
magnetic sensors (option)
empty pipe detection

EEx versions
EEx, intrinsically safe
FM Factory Mutual
Custody transfer (in preparation)

Flow measurement, e.g.


liquids, pastes
sludges and slurries, contents ≤ 3%
contents ≤ 5%
contents ≤ 30%
pulsating flow, 200 pulses/min
batching process
paper and pulp industries
dredging industry
hydraulic transport (ore dressing)
partially filled pipes, only IFC 110 PF
capacitive signal pickup, only IFC 090 K-CAP

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit
1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” for IFC 090 K-CAP 3) see Data sheet “TIDAFLUX IFM4110PF” for IFC 110 PF

8 Background 3.1
Signal converters SC 150 F

Background
for electromagnetic flowmeters IFC 012 K / 014 K
IFC 210 E
Selection guide
IFC 110 F + IFC 110 PF
IFC 090 K, F + IFC 090 K–CAP

Wastewater
IFC 020 K, F, E

Water
IFC 010 K, F

1 2 3 4 5 6 7

corrosive and measurement Beverage,


hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive,
Current output
0 / 4 - 20 mA
0 / 4 - 20 mA and others

Pulse output

Non-contact
0-10 pulses/s (scalable)
0-100 Hz, 0-1 000 Hz for full-scale
0-1 000 Hz for full-scale, scalable
0-10 000 Hz for full-scale, scalable

Status (binary) output

Food,
1 for e.g. flow direction, indications
max. 2 e.g. for flow direction, limits
4 for e.g. flow direction, automatic range change
Control input

High Pressure
and special
max. 2 for e.g. totalizer reset, hold outputs
Interface
HART®, RS 485 (standard)
HART®, smart, RS 485 (option)
HART® (option)

and Remote
Profibus

Integral
Fieldbus

Signal converter
others on request

Power consumption
≤ 3W
≤ 5W

Remote
≤ 5 VA / 4 W
≤ 10 VA / 8 W
≤ 11 VA / 14 W
≤ 15 VA / 15 W
≤ 50 VA
Calibration /
Measuring
Principle

Power supply
24, 48, 100-240 V AC, 48-63 Hz
24 V DC
85-264 V AC, 48-63 Hz
Sizing / instal-

24 V AC / DC
lation guides

100-240 V AC, 48-63 Hz


Ordering
guide

2) 3) 1)

K = compact unit (integral converter) F = seperate unit, remote signal converter in field housing E = seperate unit, remote signal converter in 19“ plug-in unit
1) see Data sheet “BATCHFLUX/BATCHCONTROL” 2) see Data sheet “CAPAFLUX IFM5080K-CAP” for IFC 090 K-CAP 3) see Data sheet “TIDAFLUX IFM4110PF” for IFC 110 PF

Background 3.1 9
Integral systems ECOFLUX AQUAFLUX ALTOFLUX
of IFM 1010 K 010 K IFM 4010 K
IFM 1020 K 020 K IFM 4020 K
electromagnetic IFM 1080 K 080 K IFM 4080 K
flowmeters

Characterization ● Flangeless version ● Flanged connections ● Flanged connections


● Rugged measuring tube with ● Steel housing ● Steel housing
stainless steel reinforced ● µP-signal converter in plastics ● Teflon® PFA liner, reinforced with
Teflon® PFA liner housing stainless steel mesh, for high
● Particularly economical ● Available with or without chemical, vacuum and abrasion
● Wide field of application indicator resistance
● Particularly economical

Signal converter, see page 8 IFC 010 K, IFC 020 K or IFC 090 K IFC 010 K, IFC 020 K or IFC 090 K IFC 010 K, IFC 020 K or IFC 090 K
Electrical conductivity ≥ 5 µS/cm (water ≥ 20 µS/cm) ≥ 20µS/cm ≥ 5µS/cm (water ≥ 20µS/cm)
Full scale range 85liter/h - 760m3/h 85liter/h - 33 000m3/h 85liter/h - 33 000m3/h
(0.3 - 12m/s) / (1 - 40ft/s) 0.3 - 3 360US Gal/min 0.3 - 156 000 US Gal/min 0.3 - 156 000US Gal/min
Meter size DN10 - 150 and 3/8” - 6” DN10 - 1000 and 3/8” - 40” DN10 - 1000 and 3/8” - 40”
Pressure rating up to 16bar/230psig, up to 40bar/580psig up to 40bar/580psig
Product temperature – 25 to + 120°C/– 13 to + 248°F – 5 to + 90°C/+ 23 to + 194°F – 60 to + 140°C/– 75 to + 284°F
Protection category (IEC 529/EN 60 529) IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6
Materials measuring section/liner Teflon® PFA ≥ DN 25 / ≥ 1” hard rubber Teflon® PFA, Teflon® PTFE,
≤ DN 20 / ≤ 3/4” Teflon® PTFE ETFE (Tefzel), (others on request)
electrodes Hastelloy C4 Hastelloy C4 Hastelloy C4, platinum, titanium,
stainless steel 1.4571/316 Ti.
Hazardous European Standard no no EEx dqe or dq ib IIC T3 . . . T6
duty versions* FM-Factory Mutual Class I, II, III, Div 2** no Class I, II, III, Div 1, 2

Fields of application
Industry environmental engineering, water environmental engineering, the ”workhorse” for water, sewage
and sewage, agriculture, water and sewage and waste water, chemicals,
batching of fertilizers and liquids feeds paper, cellulose, ore dressing

Abrasion resistance very good higher than required for dependent on liner material, very high
the applications in question with Teflon® PFA
Chemical resistance of liner
... with alkalis, e. g. NaOH NaOH up to 70% at 20°C/68°F NaOH up to 50% at 20°C/68°F all concentrations with Teflon® PFA or
PTFE liners
... with acids, e. g. HNO3 HNO3 up to 65% at 20°C/68°F HNO3 up to 5% at 20°C/68°F all concentrations with Teflon® PFA or PTFE liners

(limited by electrode material) (select materials for grounding rings


and gaskets for process compatibility)

10 Background 3.1
PROFIFLUX VARIFLUX CAPAFLUX BATCHFLUX

Background
IFM 5010 K IFM 6010 K IFM 5080 K-CAP BATCHCONTROL
IFM 5020 K IFM 6020 K
IFM 5080 K IFM 6080 K

Wastewater
Water
corrosive and measurement Beverage,
hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive,
● Precision flowmeter
● With capacitive signal pickup
(electrodes not in contact with

Non-contact
the product)
● Minimum required electrical
conductivity only 0.05µS/cm
(water: 1µS/cm)
● No need for selection of ● Excellent measuring accuracy
electrode material, liner has and repeatability
high chemical resistance ● Dimensionally stable Al2O3

Food,
● No electrochemical effects at measuring tube, suitable for SIP
● Flangeless version ● Various sanitary/flanged the electrodes, also suitable and CIP cleaning
● Stainless steel housing connections 7for the most difficult chemical ● Crevice-free CERMET electrodes
● The only precision flowmeter ● Stainless steel housing processes ● Specially developed for use on

High Pressure
and special
with flow profile-optimizing ● FDA approved Teflon® PFA liner, ● Not affected by electrically filling machines
measuring tube vacuum resistant, CIP and SIP insulating deposits ● Fast and accurate volumetric
● Influence on measuring cleaning facilitated by unique ● Abrasion resistant, suitable for filling processes for even the
accuracy from temperature, metal reinforcement of the PFA products with high solids contents smallest amounts
viscosity, pressure and flow ● Largest assortment of sanitary ● No crevices, no blind spots: ● Batching times > 1s
profile is extremely slight connections sanitary ● Low power consumption, < 3W

and Remote
● With flow profile-optimizing ● Also available with integrated

Integral
measuring tube batch controller

Signal converter
IFC 010 K, IFC 020 K or IFC 090 K IFC 010 K, IFC 020 K or IFC 090 K IFC 090 K-CAP (similar to IFC 090 K) IFC 011 K (similar to IFC 010 K)
≥ 5µS/cm (water ≥ 20µS/cm) ≥ 5 µS/cm (water ≥ 20 µS/cm) ≥ 0,05 µS/cm (water ≥ 1 µS/cm) ≥ 5 µS/cm (water ≥ 20 µS/cm)
6liter/h - 340m3/h 6 liter/h - 220 m3/h 530 liter/h - 340 m3/h 6 liter/h - 50 m3/h
0.02 - 1 500US Gal/min 0.75 – 54ft/s 0.3 - 950 US Gal/min 2.3 - 1 500 US Gal/min 0.02 - 220 US Gal/min

Remote
DN 2.5 - 100 and 1/10” - 4” DN 2.5 - 80 and 1/10” - 3” DN 25 - 100 and 1” - 4” DN 2.5 - 40 and 1/10” - 11/2”
up to 40bar/580psig up to 40 bar/580 psig up to 40 bar/580 psig up to 10 bar/150 psig
– 60 to + 140°C/– 75 to + 284°F – 60 to + 140°C/– 75 to + 284°F – 20 to + 100°C/– 4 to + 212°F 5 – 25 to + 140°C/– 13 to + 284°F
IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6
fused aluminium oxide, 99.7% Al2O3 Teflon® PFA fused aluminium oxide, 99.7% Al2O3 fused aluminium oxide, 99.7% Al2O3

Calibration /
Measuring
Principle

Cermet, platinum Hastelloy C4, platinum, titanium capacitive electrodes, Cermet, platinum
stainless steel 1.4571/316 Ti not wetted
EEx dme ib IIC T3 . . . T6 EEx dme ib IIC T3 . . . T6 yes, no
Class I, II, III, Div 2** Class I, II, III, Div 1, 2** yes, in preparation no
Sizing / instal-
lation guides

all applications requiring extremely food and beverage, pharmaceutical, all sectors where what counts are leak-tight batching of fertilizers and liquid feeds
high measuring stability under cosmetics, chemical and crevice-free tubes for flow-metering the
arduous operating conditions. most difficult products, including low-
conductivity and deposit-forming products
extremely high high extremely high extremely high
Ordering
guide

NaOH up to 50% at 50°C/122°F all concentrations NaOH up to 50% at 50°C/122°F NaOH up to 50% at 50°C/122°F

HNO3 up to 99% at 90°C/194°F, HF all concentrations HNO3 up to 99% at 90°C/194°F, HF HNO3 up to 99% at 90°C/194°F
(hydrofluoric acid), all concentr. up to (hydro-fluoric acid), all concentr. up to
50°C/122°F 50°C/122°F
(select materials for grounding rings (select materials for grounding rings (select materials for grounding rings and
and gaskets for process compatibility) and gaskets for process compatibility) electrodes for process compatibility)

Background 3.1 11
Primary heads ECOFLUX AQUAFLUX ALTOFLUX
of IFS 1000 F F IFS 4000 F
IFS 4005 F
electromagnetic
flowmeters

● Flangeless version ● Flanged connections ● Flanged connections


● Rugged measuring tube with ● Steel housing ● Steel housing
stainless steel reinforced ● Liner of Polypropylene, NSF- ● Teflon® PFA liner, reinforced with
Teflon® PFA liner approved Polyurethane liner stainless steel mesh, for high
● Particularly economical and KTW approved hard chemical, vacuum and abrasion
Characterization ● Wide field of application rubber quality resistance
● Particularly economical ● IFS4000F for largely
homogeneous liquids,
slurries, pastes
● IFS 4005 F for liquids with high
solids content
Magnetic system pulsed DC field pulsed DC field pulsed DC field
Electrical conductivity ≥ 5 µS/cm (water ≥ 20 µS/cm) ≥ 20µS/cm ≥ 5µS/cm (water ≥ 20µS/cm)
Full scale range 85liter/h - 760m3/h 85liter/h - 305 000m3/h 85 liter/h - 305 000 m3/h
(0.3 - 12m/s) / (1 - 40ft/s) 0.3 - 3 360 US Gal/min 0.3 - 1 400 000US Gal/min 0.3 - 1 400 000 US Gal/min
Meter size DN10 - 150 and 3/8” - 6” DN10 - 3000 and 3/8” - 120” DN 10 - 3000 and 3/8” - 120”
Pressure rating up to 16bar/230psig up to 40bar/580psig up to 40bar/580psig
Product temperature – 25 to + 120°C/– 13 to + 248°F – 5 to + 90°C/+ 23 to + 194°F – 60 to + 180°C/– 76 to + 356°F
Protection category (IEC 529/EN 60 529) IP 67, equivalent to NEMA 4/4X IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6

Materials
measuring section/liner Teflon® PFA ≥ DN 25 / ≥ 1” hard rubber Teflon® PFA, Teflon® PTFE,
≤ DN 20 / ≤ 3/4” Teflon® PTFE ETFE (Tefzel)
electrodes Hastelloy C4 Hastelloy C4 Hastelloy C4, platinum, titanium,
stainless steel 1.4571/316 Ti.
Approvals/Tests
Hazardous duty version: European-Standard no no EEx eq ib IIC T3 . . . T6
(* in preparation) FM-Factory Mutual pending Div 2** no Class I, II, III, Div 1, 2
Food and beverage no no no

Combined with signal converter IFC 010 F / IFC 020 F, E IFC 010 F / IFC 020 F, E IFS 4000 F: IFC 010 F / IFC 020 F, E
IFC 090 F IFC 090 F IFC 090 F
IFC 110 F IFC 110 F IFC 110 F
(see Pages 8 and 9) IFS 4005 F: SC 150 F
Fields of application
Industry environmental engineering water and environmental engineering, the ”workhorse” for water, sewage and
sewage, agriculture, batching of water and sewage waste water, chemicals, paper,
fertilizers and liquids feeds cellulose, ore dressing

Abrasion resistance very good higher than required for dependent on liner material, very high
the applications in question with Teflon® PFA
Chemical resistance of liner
... with alkalis, e. g. NaOH, KOH NaOH up to 70% at 20°C/68°F NaOH up to 50% at 20°C/68°F all concentrations with Teflon® PFA or
PTFE liners
... with acids, e. g. HNO3 HNO3 up to 65% at 20°C/68°F HNO3 up to 5% at 20°C/68°F all concentrations with Teflon® PFA or PTFE liners
(limited by electrode material)

(limited by electrode material) (select materials for grounding rings


and gaskets for process compatibility)

12 Background 3.1
PROFIFLUX ALTOFLUX VARIFLUX TIDAFLUX

Background
IFS 5000 K IFS 2000 F IFS 6000 F IFS 4000 PF
IFS 2005 F

Wastewater
Water
corrosive and measurement Beverage,
hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive,
● Flangeless (sandwich) design ● Flanged connections ● Various sanitary/flanged connec- ● Designed for partially filled pipelines
● Stainless steel housing ● Steel housing tions, stainless steel housing ● Excellent measuring accuracy, also
● The only precision flowmeter ● Measuring tube made of Al2O3 ● FDA approved Teflon® PFA liner, vac- for low levels, through the integrated

Non-contact
with flow profile-optimizing almost as hard as diamonds uum resistant, CIP and SIP capacitive level measuring system
measuring tube ● High measurement and long-term cleaning facilitated by unique ● Saves installation and maintenance
● Influence on measuring stability, even with highly abrasive metal reinforcement of the PFA of sluice underpasses
accuracy from temperature, products ● Largest selection of sanitary con-
viscosity, pressure and ● IFS 2000 F: for largely homogeneous nections
flow profile is extremely slight liquids, slurries, pastes
● IFS 2005 F: for liquids with high

Food,
(and coarse-grained) solids content

pulsed DC field pulsed DC field pulsed DC field pulsed DC field


≥ 5µS/cm (water ≥ 20µS/cm) ≥ 5 µS/cm (water ≥ 20 µS/cm) ≥ 5 µS/cm (water ≥ 20 µS/cm) ≥ 50 µS/cm

High Pressure
and special
6liter/h - 340m3/h 19 liter/h - 2100 m3/h 6 liter/h - 220 m3/h 35 liter/h - 100 000 m3/h
0.02 - 1 500US Gal/min 84 - 930 US Gal/min 0.02 - 950 US Gal/min 0.2 - 500 000 US Gal/min
DN 2.5 - 100 and 1/10” - 4” DN 150 - 250 and 6” - 10” DN 2.5 - 80 and 1/10” - 3” DN 200 - 1800 and 8” - 24”
up to 40bar/580psig up to 16bar/230 psig up to 40 bar/580 psig up to 10 bar/150 psig
– 60 to + 180°C/– 76 to + 356°F – 60 to + 120°C/– 76 to + 248°F – 60 to + 180°C/– 76 to + 356°F – 5 to + 60°C/+ 23 to + 140°F
IP 67, equivalent to NEMA 6 IP 65, equivalent to NEMA 4/4X IP 67, equivalent to NEMA 6 IP 67, equivalent to NEMA 6

and Remote
Integral
Signal converter
fused aluminium oxide, 99.7% Al2O3 fused aluminium oxide, 99.7 % Al2O3 Teflon®-PFA Irathan, 12 mm/0.47”
FDA approved
Cermet, platinum Hastelloy C4, platinum Hastelloy C4, platinum, titanium, Hastelloy C4
stainless steel 1.4571/316 Ti stainless steel 1.4571/316 Ti

Remote
EEx me ib IIC T3 . . . T6 no EEx me ib IIC T3 . . . T6* Ex N, Zone 2 (option)
Class I, II, III, Div 2** Class I, II, III, Div. 2 Class I, II, III, Div. 1, 2* in preparation
yes no Dairy and Research Center no
Weihenstephan, A3

Calibration /
IFS 5000 F: IFC 010 F / IFC 020 F, E IFS 2000 F: IFC 020 F, E Measuring
Principle

IFC 090 F IFC 090 F IFC 010 F / IFC 020 F, E IFC 110 PF
IFC 110 F IFC 110 F IFC 090 F
IFS 2005 F: SC 150 F IFC 110 F

all applications requiring aluminium, ore mining, food and beverage, pharmaceutical, sewage in partially filled
Sizing / instal-
lation guides

extremely high measuring stability heat measurement cosmetics, chemical pipelines


under arduous operating conditions.

extremely high extremely high high very high

NaOH up to 10% at 30°C/86°F


Ordering

NaOH up to 50% at 50°C/122°F NaOH up to 50% at 50°C/122°F all concentrations


guide

HNO3 up to 5% at 20°C/68°F
HNO3 up to 99% at 90°C/194°F, HF HNO3 up to 99 % at 90°C/194°F all concentrations
(hydrofluoric acid), all concentr. up to
50°C/122°F

(select materials for grounding rings (select materials for grounding rings, (select materials for connections and
and gaskets for process compatibility) electrodes and gaskets for process electrodes for process compatibility)
compatibility)

Background 3.1 13
Signal converters IFC 010 K IFC 020 K IFC 090 K
for IFC 010 F IFC 020 F IFC 090 F
IFC 020 E
electromagnetic
flowmeters

● IFC 010 K/IFC 020 K of integral design ● IFC 090 K of integral design
● IFC 010 F/IFC 020 F in field housing ● IFC 090 F in field housing
● Signal processing by microprocessor, ● Signal processing by microprocessor,
good dynamic response. Basic version with dis- very good dynamic response.
play/totalizing and control unit with plain-text Basic version with display/totalizing and control
operator prompting, unit with clear-text operator prompting, all func-
Characterization all functions/data can be set. tions/data can be set (also with magnetic sen-
IFC 020: display/totalizing, HART®/ sors without opening the housing)
RS 485 interface, higher field current,
IFC 020 E 19” plug-in version.

Application
For liquids, pastes, sludges and slurries with up to 3% Liquids, pastes, sludges and slurries with solids
solids content, IFC 020 for pulsating flows with up to content up to 5%, also for pulsating flows up to
approx. 200 pump lifts/min, and batching processes. approx. 200 pump lifts/min, and batching processes
Special features
Identical electronic module for remote-system and Outstanding repeatability and dynamic response
compact flowmeters = simplified stocking of spares. through higher field frequency and field current.
Modular electronic unit easily upgradable, easily Modular electronic unit, easily upgradable, easily
adaptable to meet additional requirements adaptable to meet additional requirements.
Magnetic field excitation Bidirectional pulsed DC field. Bidirectional pulsed DC field.
Full-scale range 0.3 – 12m/s, 1 – 40ft/s 0.3 – 12m/s, 1 – 40ft/s
configurable in user-definable flow units configurable in user-definable flow units
Outputs Current 0/4 – 20 mA 0/4 – 20 mA, etc.
Pulse 0 – 10 pulses/s (scalable), 0 – 100 Hz 0 – 1000 pulses/s (scalable) for full-scale range
0 – 1000 Hz for full-scale range
Status Binary output, e.g. for flow direction error indication Binary output, e.g. for direction of flow error
indication, range selection
Control input
– Binary outputs switch-selectable to the control input, e.g.
set outputs and totalizer to zero, external range change, etc.
Interfaces (option) HART®, smart, RS 485; Profibus in preparation HART®, smart, RS 485; Profibus; Fieldbus
Power supply 24, 48, 100 – 240V AC, 48 – 63Hz and 24 V DC 24, 48, 100 – 240V AC, 48 – 63Hz and 24V DC
Power consumption 5VA / 4W 10VA / 8W
Error limits overall system ± 0.5% of measured value ± 0.3% of measured value
Standard equipment
Low-flow cutoff Low-flow cutoff, Forward/reverse flow measurement,
Forward/reverse flow measurement Automatic range change Limit contacts, External range
Limit contact selector, External totalizer reset
Test function for converter and receiver Test function for converter and receiver instruments,
instruments Galvanic isolation
Galvanic isolation Overvoltage protector (supply power and all inputs
Overvoltage protector (supply power and outputs)
and all outputs)

Other versions
Hazardous-duty version
European Standard – in preparation
FM (Factory Mutual) – in preparation

For custody transfer – in preparation

14 Background 3.1
IFC 110 F IFC 110 PF SC 150 F

Background
Wastewater
Water
corrosive and measurement Beverage,
hot products κ ≥ 0.05 µS/cm Pharmaceutical connections

Abrasive,
● Signal converter in field housing ● Signal converter in field housing for wall mounting
● Signal processing by microprocessor, ● Signal processing by microprocessor,
outstanding interference rejection, outstanding interference rejection, through high

Non-contact
very good dynamic response field frequency and field current, very good
● Basic version without display or measuring stability despite high frequency.
control unit ● Option: magnetic sensors for setting all data
● Option: display/totalizing and control without opening the housing Characterization
unit with plain-text operator prompting,
all functions/data can be set.
● IFC 110 PF for TIDALFLUX IFS 4000 PF

Food,
Application
Liquids, pastes, sludges and slurries with solids con- Liquids, pastes, slurries, sludges with solids contents

High Pressure
tents up to 5%, also for pulsating flows up to approx. in excess of 30%, e.g. paper and pulp industry,

and special
200 pump lifts/min, and batching processes hydraulic conveyance (ore dressing), dredging industry
Special features
3 status indication outputs and 2 control inputs allow Heavy-duty electronic module, Excellent measuring
easy, flexible system integration. Modular electronic signals, Outstanding repeatability through high field
unit, easily upgradable, with unassigned slots for current,
add-on board Designed for toughest process conditions

and Remote
Bidirectional pulsed DC field, field. Bidirectional, pulsed high-power DC field. Magnetic field excitation

Integral
0.3 – 12m/s, 1 – 40ft/s configurable in user- 0.3 – 12m/s, 1 – 40ft/s configurable in user- Full-scale range

Signal converter
definable flow units definable flow units
0/4 – 20mA, etc. 0/4 – 20mA, etc. Outputs Current
0 – 10 000 pulses/s (scalable) 0 – 10 000 pulses/s (scalable) Pulse

4 binary outputs, e.g. for flow direction, Binary output, e.g. for direction of flow, Status

Remote
error indication, automatic range change error indication
Control input
2, e.g. totalizer reset, hold outputs, set outputs to –
zero, test
HART®, smart, RS 485; Profibus in preparation RS 485 Interfaces (option)
Calibration /
Measuring
Principle

85 – 264V AC, 48 – 63 Hz and 24V DC/AC 100 – 240V AC, 48 – 63Hz Power supply
15VA / 15W approx. 50VA Power consumption
± 0.3% of measured value (option: 0.2%) ± 0.4% of measured value Error limits overall system
Standard equipment
Sizing / instal-
lation guides

Low-flow cutoff, Forward/reverse flow measurement, Low-flow cutoff, Forward/reverse flow measurement
Automatic range change, Limit contacts, External Automatic range change, Limit contacts,
range selection, External totalizer reset, Function test Galvanic isolation
of converter and receiver instruments,
Galvanic isolation Overvoltage protector (supply power
and all inputs and outputs)
Ordering
guide

Other versions
Hazardous-duty version
in preparation – European Standard
in preparation – FM (Factory Mutual)

in preparation – For custody transfer

Background 3.1 15

Você também pode gostar