brakes 1) Freely suspended or mounted on an insulator 2) Mounted on a painted metal sheet of min. 250 x 250 x 1 mm SKB V (BR) min V VRMS l D = 5 A (T a = 45 C) C max R min V V Types F C 1300 500 SKBa B500/445-4 2 Symbol Conditions Values Units l D T a = 45 C, isolated 1) 5 A T a = 45 C, chassis 2) 5 A l DCL T a = 45 C, isolated 1) 4 A T a = 45 C, chassis 2) 4 A l FSM T vj = 25 C, 10 ms 180 A T vj = 150 C, 10 ms 150 A it T vj = 25 C, 8,3 ... 10 ms 160 As T vj = 150 C, 8,3 ... 10 ms 110 As P RSM t p = 10 s 3000 W V F T vj = 25C, l F = 80 A max. 2,65 V V (TO) T vj = 150C 0,8 V r T T vj = 150C 24 mC l RD T vj = 25C, V RD =V (BR) min 10 A l RD T vj = 150C, V RD =V (BR) min 0,6 mA t rr T vj = 25C 10 s f G 2000 Hz R th(j-a) isolated 1) 13 K/W T vj - 40 ... + 150 C T stg - 55 ... + 150 C M s to heatsink 1,5 15% Nm M t to terminals 1 15 % Nm m 60 g Fu 6 A Case G 8 SKBa B500/445-4 1 15-01-2010 CLG by SEMIKRON Fig. 1 Rated output current vs. ambient temperature Fig. 2 Power dissipation vs. output current Fig. 6 Rated overload characteristics vs. time Fig. 7 Rated reverse power dissipation vs. time Fig. 9 Forward characteristics of a diode arm SKBa B500/445-4 2 15-01-2010 CLG by SEMIKRON Dimensions in mm Case G 8 * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON. We therefore strongly recommend prior consultation of our personal. SKBa B500/445-4 3 15-01-2010 CLG by SEMIKRON