Objectives
Describe the function of the hydraulic system reservoir and identify the primary design features involved in its construction. Explain the factors that must be considered when establishing the size of a reservoir for use in a system. Describe the factors that are basic to the design and structure of fluid conductors used in hydraulic systems.
Goodheart-Willcox Co., Inc.
Objectives
Compare and contrast the various types of pipe, tubing, and hose used in hydraulic systems and explain the ratings for each conductor. Identify and explain the factors that must be considered when selecting a conductor for use in a hydraulic system. Explain the information typically found on data sheets provided by the manufacturers of hydraulic system pipe, tubing, and hose.
Goodheart-Willcox Co., Inc.
Reservoir
The primary purpose of the reservoir is to hold the system fluid not currently in use in the system Other important functions of the reservoir are:
Remove heat Separate solid particles Release air from fluid Separate water from fluid
5
Permission granted to reproduce for educational use only.
Reservoir
The reservoir serves many functions
Reservoir
The typical hydraulic system reservoir is a rectangular, covered steel tank The tank is typically fitted with:
Pump inlet line System fluid return line Drain line Filler cap Air breather Fluid-level indicator
7
Permission granted to reproduce for educational use only.
Reservoir
Baffles are used in the interior of reservoirs to direct flow to maximize the distance the fluid must travel between the return line and the pump inlet line
Slows the movement of the fluid Increases cooling Increases separation of solid particles, air, and water
Reservoir
Baffles are typically included in a reservoir
Reservoir
Typical reservoir construction
10
Reservoir
L-shaped and overhead reservoir designs may be used in systems where positive pressure is needed on the pump inlet line
11
Reservoir
L-shaped reservoir
12
Reservoir
Overhead reservoir
13
Reservoir
In special situations, the system reservoir may be:
Cavities in large machines Gear cases in mobile equipment
14
Reservoir
As a general rule, the capacity of the reservoir should be three times the rated flow of the pump
Fixed installations may be higher Mobile applications, where weight and space are factors, may be less
15
Conductors
The proper selection, installation, and maintenance of conductors is critical to efficient hydraulic system operation
16
Conductors
Pipe, tubing, and flexible hose are considered basic conductors in a hydraulic system
17
Conductors
Conductors must have:
Adequate strength to withstand high system pressures Low flow resistance to assure low energy loss during system operation A design that allows economic installation and low maintenance
18
Conductors
Conductors must not only withstand normal system operating pressure, but also hydraulic shock pressures Shock pressures result from kinetic energy in the system when:
Directional control valves are shifted to reverse the movement of a load or heavy machine member Actuators encounter sudden load changes
19
Conductors
Low flow resistance requires a conductor with an inside diameter large enough to allow the needed volume of fluid to move through the line within recommended fluid velocities
20
Conductors
Restrictions may cause turbulent flow
21
Conductors
Flow resistance in a system results from resistance to fluid flow caused by:
Surface of the conductor Bends and fittings in the lines Orifices in components Turbulence in the fluid stream Viscosity of the fluid
22
Conductors
Fluid flow resistance resulting from fluid movement through conductors and other system components:
Lowers the work output of a system Produces heat, which may cause operating problems
23
Conductors
Future maintenance must be carefully considered when designing and installing hydraulic system conductors to assure minimal difficulty in removing components for service
24
Conductors
Pipe in a hydraulic system should be:
Seamless, black pipe ANSI schedule rating of 40, 80, or 160, depending on the maximum pressure expected in the system
25
Conductors
Various nominal pipe dimensions
26
Conductors
Schedule number indicates wall thickness
27
Conductors
Tubing:
Is a relatively thin-walled, semirigid conductor Can be bent and shaped into lines that provide good flow characteristics with a minimum of visual clutter
28
Conductors
Tubing can be bent, unlike pipe
29
Conductors
The size of tubing is indicated by the actual outside diameter
Inside diameter varies according to wall thickness Most tubing is manufactured to the specifications of a standardizing organization such as ANSI or SAE
30
Conductors
Hose is a flexible conductor made up of:
Inner tube to conduct the fluid Middle layer of reinforcing material for strength Outer protective coating to withstand abrasion and abuse
31
Conductors
Hose with braided-wire middle layers
Gates Corporation
32
Conductors
Hose with spiral-wound-wire middle layers
Gates Corporation
33
Conductors
Hose provides flexibility
34
Conductors
A wide variety of hoses are available, often making selection difficult Standardizing organizations provide guidelines that help compare various products on the market
35
Conductors
Manifolds are machined or fabricated parts used to distribute system fluid They are often used to help produce a lighter, more-compact system
36
Conductors
A wide variety of fittings are available to assist in attaching conductors to system components such as:
Reservoir Pump Valves Actuators
37
Conductors
Careful selection of fittings can:
Help control construction costs Improve system efficiency Allow easier system maintenance
38
Conductors
Dryseal standard pipe threads should be used on pipe fittings, rather than standard pipe threads, to assure a tight thread seal that will not leak under high system pressure
39
Conductors
Standard pipe threads
40
Conductors
Dryseal standard pipe threads
41
Conductors
Fittings with pipe threads or straight threads sealed with an O-ring or a metal compression washer are typically used to attach tube and hose to hydraulic components Tubing is attached to fittings by flaring the tube, compression, soldering, or brazing
42
Conductors
Hose attached to an actuator with elbow fitting and adapter with pipe threads
43
Conductors
Hydraulic systems typically use a 37 flare angle
Gates Corporation
44
Conductors
Compression fittings use an O-ring, ferrule, sleeve, or patented configuration to provide the seal
45
Conductors
Soldered or brazed fittings usually use split flanges to mount the fitting to the component
46
Conductors
Metal hose-end fittings are used to connect flexible hose to the components of the system
Available in both permanently attached or reusable styles Attached to the components using pipe threads, flare fittings, or split flange fittings
47
Conductors
Reusable hose-end fittings are either:
Screw-together type Clamp type
These fittings can be assembled to the hose using basic hand tools, which allows field assembly
48
Conductors
Permanently attached hose-end fittings are crimped or swaged onto the hose Special equipment is required to install this type of fitting on a hose
49
Conductors
Crimped hose-end fittings
Gates Corporation
50
Conductors
Swaged hose-end fitting
Gates Corporation
51
Conductors
A wide variety of adapter fittings are available for making proper connections between conductors and system components:
Transitions from one thread type to another Elbows at 45 and 90 Swivels that allow component movement
52
54
55
56
57
58
59
60
Conductor Installation
When installing pipe and tubing, it is important to have the correct lengths
Should not be distorted Should not be placed under tension Distortion and tension can result in material fatigue and lead to part failure
61
Conductor Installation
When installing tubing, the number of fittings in a system can be reduced by bending the tube where possible Hand tools and power equipment are available to produce accurate bends
62
Conductor Installation
Long lengths of pipe and tubing should be supported by brackets or clamps to secure the conductor This will reduce fatigue caused by conductor weight or system vibration
63
Conductor Installation
System pressure changes will change the length and diameter of a hose
Allow slack in the hose Allow adequate hose-to-member clearances
64
Conductor Installation
Allow slack in hose when it is installed
Gates Corporation
65
Conductor Installation
When hose is installed, ensure it is not twisted
Gates Corporation
66
Conductor Installation
When assembling hydraulic system conductors and their associated fittings and adapters, the result should:
Be a neat and uncluttered conductor layout Efficiently distribute fluid throughout the system
67
Conductor Installation
A clean and efficient conductor installation
68
Review Question
The component that is designed to hold the fluid not currently in use in the system is called the _____. reservoir
69
Review Question
What are the two reservoir configurations that are suitable for use with a pump that requires a positive pressure on the inlet line? A. L-shaped and B. overhead
70
Review Question
List the three basic categories of fluid conductors used in hydraulic systems.
71
Review Question
American National Standards Institute (ANSI) schedule numbers identify the _____ of pipes.
wall thickness
72
Review Question
List three factors assured by the proper selection and installation of pipe, tube, or hose fittings in hydraulic systems. A. Reasonable initial construction cost, B. efficient system operating, and C. minimal ongoing maintenance.
73
Review Question
Name four situations that may result if conductors and fittings are not carefully selected for a given hydraulic system.
A. Conductors may cost more than necessary, B. inefficient system operation, C. parts may prematurely fail, and D. disassembly may be more difficult than necessary during service.
74