Você está na página 1de 6

SIMATIC

ze e diogo\SIMATIC 300(1)\CPU 313\...\OB1 - <offline>

03/12/2013 02:02:36 AM

OB1 - <offline>
Family: Version: 0.1 Block version: 2 03/12/2013 02:02:27 AM Time stamp Code: 02/15/1996 04:51:12 PM Interface: Lengths (block/logic/data): 00386 00238 00020 "" Name: Author:

Name TEMP OB1_EV_CLASS OB1_SCAN_1 OB1_PRIORITY OB1_OB_NUMBR

Data Type

Address 0.0

Comment

Byte Byte Byte Byte

0.0 1.0 2.0 3.0 4.0 5.0 6.0 8.0 10.0

Bits 0-3 = 1 (Coming event), Bits 4-7 = 1 (Event class 1) 1 (Cold restart scan 1 of OB 1), 3 (Scan 2-n of OB 1) Priority of OB Execution 1 (Organization block 1, OB1) Reserved for system Reserved for system Cycle time of previous OB1 scan (milliseconds) Minimum cycle time of OB1 (milliseconds) Maximum cycle time of OB1 (milliseconds) Date and time OB1 started

OB1_RESERVED_1 Byte OB1_RESERVED_2 Byte OB1_PREV_CYCLE Int OB1_MIN_CYCLE OB1_MAX_CYCLE OB1_DATE_TIME Int Int

Date_And_Time 12.0

Block: OB1

"Main Program Sweep (Cycle)"

Network: 1 Etapa inicial M0.1

M0.0

M0.7 M0.0

I1.1

M0.0

I1.7

Page 1 of 6

SIMATIC

ze e diogo\SIMATIC 300(1)\CPU 313\...\OB1 - <offline>

03/12/2013 02:02:36 AM

Network: 2

M0.1

O motor M2 liga para ativar a passadeira M0.2 M0.0 M0.7 M0.1 I0.1 I1.1 I0.2 M0.1

Network: 3

M0.2

S1 deteta recipiente e abre eletrovalvulas V1, V2 e V3 M0.3 M0.1 M0.2 I0.3 I0.2 M0.2

Network: 4

M0.3

Nivel minimo P1 atingido e fecho da eletrovalvula V1. M0.4 M0.2 M0.3 I0.4 I0.2 M0.3

Network: 5

M0.4

Ao fim de 10s fecho eletrovalvula V2 M0.5 M0.3 M0.4 T1 I0.2 M0.4

Page 2 of 6

SIMATIC

ze e diogo\SIMATIC 300(1)\CPU 313\...\OB1 - <offline>

03/12/2013 02:02:37 AM

Network: 6

M0.5

Nivel maximo do tanque atingido Misturador M1 no velocidade rapida durante 60s M0.6 M0.4 M0.5 I0.6 I0.2 M0.5

Network: 7

M0.6

Fim temporizador 2 Abertura da eletrovalvula 4 para encher o recipiete durante 30s M0.7 M0.5 M0.6 T2 I0.2 M0.6

Network: 8

M0.7

Fim do temporizador 3 M0.0 M0.1 M0.6 M0.7 T3 I0.2 M0.7

Network: 9 Temporizador 10s

T1

M0.3 S S5T#10S TV R

T1 S_ODT Q BI BCD

Page 3 of 6

SIMATIC

ze e diogo\SIMATIC 300(1)\CPU 313\...\OB1 - <offline>

03/12/2013 02:02:37 AM

Network: 10 Temporizador 60s

T2

M0.5 S S5T#1M TV R

T2 S_ODT Q BI BCD

Network: 11 Temporizador 30s

T3

M0.6 S S5T#30S TV R

T3 S_ODT Q BI BCD

Network: 12 Sinalizador se sistema ligado M0.1 M0.2 M0.3 M0.4 M0.5 M0.6 M0.7 Q4.1

Page 4 of 6

SIMATIC

ze e diogo\SIMATIC 300(1)\CPU 313\...\OB1 - <offline>

03/12/2013 02:02:37 AM

Network: 13 Motor M2 em funcionamento M0.1 Q4.0

Network: 14 Abertura eletrovalvula V1 M0.2 Q4.2

Network: 15 Abertura eletrovalvula V2 M0.2 M0.3 Q4.3

Network: 16 Abertura eletrovalvula V3 M0.2 M0.3 M0.4 Q4.4

Page 5 of 6

SIMATIC

ze e diogo\SIMATIC 300(1)\CPU 313\...\OB1 - <offline>

03/12/2013 02:02:38 AM

Network: 17 Misturador M1 lento M0.3 M0.6 Q4.6

Network: 18 Misturador M1 rapido M0.5 Q4.7

Network: 19 Abertura eletrovalvula 4 M0.6 Q5.1

Page 6 of 6