VARUN - MULTIGRADE FILTER SERIES Removes the suspended solid present in water using graded sand & media.

Inlet Turbidity range: 5 25 NTU; Outlet Turbidity range: 1 5 NTU SCHEME:


FILTER FEED PUMP MULTIGRADE FILTER

PRODUCT CODE

VARUN MGF 600/2300 VARUN MGF 800/2300 VARUN MGF 1200/2300 VARUN MGF 1400/2300 VARUN MGF 1600/2300

MAX FLOW RATE 3 (m /hr) 8 15 34 46 60

DESIGN PRESSURE & TEMP

3.5 kg/cm & 45 c

VARUN - ACTIVATED CARBON FILTER SERIES Removes the free chlorine & odour from water using carbon media. SCHEME:
FILTER FEED PUMP ACTIVATED CARON FILTER

PRODUCT CODE

VARUN ACF 600/2000 VARUN ACF 800/2000 VARUN ACF 1000/2000 VARUN ACF 1200/2000 VARUN ACF 1600/2000

MAX FLOW RATE 3 (m /hr) 8 12 18 27 48

DESIGN PRESSURE & TEMP

3.5 kg/cm & 45 c

VARUN - SOFTNER SERIES Removes hardness from water by replacing the ion with the help of ion exchange resin & the same can be regenerated by using brine solution. Inlet hardness range: 50 500 PPM; Outlet hardness range: 2 10 PPM SCHEME :
SOFTNER FEED PUMP SOFTNER

PRODUCT CODE

VARUN SF 600/2500 VARUN SF 1200/2000 VARUN SF 1400/2500 VARUN SF 1600/2500


VARUN RO

MAX FLOW RATE 3 (m /hr) 7.5 50 70 90

DESIGN PRESSURE & TEMP

3.5 kg/cm & 45 c

To reduce total dissolved solids and unwanted minerals


SCHEME:
MICRON CARTRIDGE FILTER HIGH PRESSURE PUMP REVERSE OSMOSIS SYSTEM

PARAMETERS Flow Pressure Temperature TDS pH

INLET 1-20 m /hr 5-25 15-45


3

OUTLET 0.5-10 m /hr


3

kg/cm c

0.5-1 15-45

kg/cm c

<2000 ppm -

<50 ppm 6.5-7

VARUN ULTRA FILTRATION SERIES Hydrostatic pressure forces a liquid against a semi permeable membrane. Suspended solids and solutes of high molecular weight are retained, while water and low molecular weight solutes pass through the membrane. Acknowledged for its outstanding advantages like energy saving, chemical resistance, wide pH range, back-washable, easy to operate & maintain, low investment cost etc
SCHEME: UF FEED PUMP
BASKET/PRE FILTER UF SYSTEM

PARAMETERS Flow Operating Pressure Turbidity Colloidal Silica Bacteria & Virus

INLET 2-80 m /hr 1 3.5 kg/cm 15 NTU 2


3

OUTLET 1.6-64 m /hr 0.5 1 kg/cm 0.1 NTU 95 to 99 % 95 to 99 %


2
3

VARUN - DEMINERALISATION SERIES DM series contains strong acid cation, strong base anions & mixed bed polisher pressure vessel. It removes cations & anions present in water. It contains exchanger resin which can be regenerated during regeneration cycle when it exhausts during the process.
SCHEME:

SAC

DG

SBA

MB

SAC- Inlet pH range: 7 8; Outlet pH range: 2 4 ; SBA- Inlet cond. : 100 700 S/cm Outlet cond. : 10 30 S/cm Inlet silica: 1 50 ppm; Outlet silica : 0.1 5 ppm Inlet pH range : 2 4 ; Outlet pH range: 7.5 9.5 ; MB- Inlet cond. : 10 30 S/cm Outlet cond. : < 1 S/cm Inlet silica : 1 30 ppm; Outlet silica : 0.1 0.01 ppm Inlet pH range : 7.5 9.5; Outlet pH range: 6.8 7.2 PRODUCT CODE FOR SAC VARUN SAC 600/1500 VARUN SAC 1000/1500 VARUN SAC 800/1500 VARUN SAC 1200/1500 PRODUCT CODE FOR MB PRODUCT CODE FOR SBA VARUN SBA 400/2300 VARUN SBA 600/2300 VARUN SBA 800/2500 VARUN SBA 1000/2500 MAX FLOW RATE 3 (m /hr) 3.5 7.5 30 40-60 MAX FLOW RATE 3 (m /hr) 7.5 15 25 40 DESIGN PRESSURE & TEMP

3.5 kg/cm & 45 c

DESIGN PRESSURE & TEMP

VARUN MB 300/1500 VARUN MB 400/1600 VARUN MB 800/2000 VARUN MB 1000/2020

3.5 kg/cm & 45 c

VARUN DG SERIES To remove dissolved carbonic acid from water which is produced during RO, SAC. In Inlet free CO2: 60 120 ppm ; Outlet free CO2: 5 10 ppm PRODUCT CODE MAX FLOW DESIGN RATE PRESSURE & 3 (m /hr) TEMP
VARUNDG-250/1500 VARUNDG-600/2600 VARUNDG-800/2600 VARUNDG-1000/2800 1.0 6.0 10.0 23.0

Atmospheric

Mobile Toilet with sewage treatment plant Used as a mobile toilet, with sewage treatment plant. Treated water is reused for toilet flushing & considerably reduces demand of makeup water (fresh water). Ideally suitable for Construction Sites, Labour Camps, Event Sites where people gather.
PRODUCT CODE FOR MOBILE STP PELCT1 PELCT2 PELCT3 MAX FLOW 3 RATE (m /hr) 0.5 1 1.5 3.5 kg/cm & 30 c
2

DESIGN PRESSURE & TEMP

Package Sewage Treatment Plants (MBBR / MBR) Packaged sewage treatment plant is a pre-engineered and pre fabricated unit of treating sewage with an aerobic process. Treated non-potable water can be used for agricultural aquaculture & industrial applications. It is based on MBBR media & MBR Rotating Biological Contractor (RBC)
Attached growth biological treatment system, and similar to that occurring in the trickling filter. This system consists of a series of hollow/solid circular disks mounted side by side on a common shaft driven by suitable HP & RPM motor in a suitable capacity tank/reactor. The waste water/sewage is passed through at one end and treated water with bioflocs is collected at other end and the same is sent of the secondary clarifier ( of conventional/ lamella type) for clarification of treated water. This is accomplished by means of consuming surface oxygen by the attached microbial content and organic matter in reactor while the discs are in rotation. The settled sludge secondary clarifier is recycled back/ sent is the sludge disposal area. It is very low power consuming system at slow rotations. For better efficiencies we generally adopt two stage RBC system

VARUN SERIES CAN OFFER: MODE OF OPERATION: Manually Semi automated Fully automated USED FOR : Drinking Waste water treatment Feed for process equipments SPECIALITY: Easy to handle Easy to operate & maintain Minimum required foot print Applicable for various range of parameter

FEATURES: Reputed makes high & Quality bought out items reputed for their quality MOC: SS / MS / FRP Necessary Instruments Frontal piping in MSRL / UPVC / CPVC / HDPE Available at with skids / without skids APPLICATION: Institutes, Shopping Malls etc Small, Medium & Large industries Food & Beverage Industries Pharma Industries Dairy Industries Fibre & Cigarette Industries Mid range power plants OUR STRENGTH :

Technical high end products Competitive price

Precious on timely deliver. Excellent service network all over India and overseas

Você também pode gostar