Você está na página 1de 31

The New Global

The Campus That Connects.

Brittany Wachsmann

CEA B7 2013

Melody Mitchell

Goals, Criteria and Constraints Bigger, better addition to Global Close, affordable Maintains style Holds 600 students + faculty Green

Gantt Chart

Maps

General

Topographic

Soils

Flood

Zoning

Preliminary Work

Client Survey - Don Snook

Adjacency Matrix

Bubble Map

Room Planning

Placement Planning - Before

Placement Planning - After

Codes, Calculations, Construction

Codes Requirements

This project adheres to the International Building Code, 2009 for all codes and regulations. From the EllisCAD, the project site is located in a school zone. To meet the ADA requirements for accessibility, entrance ramps, wheelchair accessible sidewalks, and handicap-accessible restrooms have been included.

Type of Construction
Based on the type of building (Institution) and style of partner campus, we will be building it out of concrete, brick, wood and it will be 50 feet high, and 3 stories. This is from the IBC building types based on size and use of our facility section 302. Adhering to ADA codes and occupancy requirements, we will have a minimum 150 parking spaces, and 5 accessible parking spaces. Section 1106.

Heat Loss
Material Brick 90lb/ft^3 0.2 5.78 Fiberglass Insulation 4 Vapor Barrier 0 Inside air film 0.68 Door with Double glazed Window 1.67 Gypsum Wall Board 0.9 Q' = 73,929 x 1/5.78 x 68 Q' = 869,752 Btu/hr R-Value

Water Run-Off
PRE I = 2.17in Ai = 36,299.92 C = .18 Cs = 1.0 Q = (2.6)(.18)(2.17)(5.19458) = 5.28cfs POST (1)(5.19458) + (2.7)(5.19458) = 16.47cfs Cc (1)(.83) + (.18)(.69) = .95 Cc = .95 Q = CfCiA = (1)(.95)(2.17)(5.2) = 10.7cfs Difference = 10.7 5.28 = 5.42cfs

Water Supply Calcs

Building Model

First Floor

Second/Third Floor

Inside the Walls

Interior View to Football Field

Lunch Level Two

Classroom Level Three

Camera View - Commons Level One

Camera View -Women's Bathroom Level One

Thank You
The Campus That Connects.