Design of Tube Settler Note: Data in yellow cell to be suitably filled for particular application.

Data in green cell to be reviewed and updated if need be. Description Value Units Number of Tube Settlers 1 Design Flow 100.00 MLD
4,347.83 m3/hr. Design Flow Each Detention in Flocculation Zone Detention in Clarification Zone Volume in Flocculation Zone Volume in Clarification Zone OD of Central Shaft C/S Area of Central Shaft Surface Loading Rate in Clarification Zone Area of Clarification zone SWD Clarification Zone - required SWD Clarification Zone - provided SWD Flocculation Zone - provided Area Flocculation Zone Total Area Flocculation Zone Dia Flocculation Zone Flocculator wall thickness OD Flocculation Zone Outer Area Flocculation Zone Total Area required in Clarification zone Dia required Considering wastage of space due to inclined tube settler, say Launder width Launder wall thickness Approx Launder Area Area incl launder required Dia required say Free Board Bottom Slope Velocity in Inlet Pipe Area Required Inlet Pipe Dia required Provide Inlet Pipe The effective available area for installing tube settler is Note: Data in yellow to be reviewed and suitably filled 4,350.00 m3/hr. 0.50 hr 0.40 hr 2,175.00 m 1,740.00 m 1.10 m 0.95 156.00 669.23 2.60 3.00 3.30 660.04 29.00 29.00 0.15 29.30
3 3

m m3/m2/day m2 m m m m2 m m m m

659.09 m2

673.91 m2 1,343.15 m2 41.36 m 42.00 m 0.60 m 0.10 m 107.51 m2 1,492.25 43.40 43.40 0.30 1 in 12 1.00 1.21 1.24 2 *700 mm dia 710.83 m2 m m m m/s m m mm Sq. m