Escolar Documentos
Profissional Documentos
Cultura Documentos
REV. 00/2011
Founded in 1965, CONAUT is leading the Brazilian market for instrumentation and industry automation, acting in all industrial elds, such as: oil and gas, petrochemical, chemical, mining, food and beverages, alcohol, water treatment and pulp and paper. CONAUTs line of products include instruments for level and ow controls such as magnetic and ultrasonic ow meters; CONAUT also represents in Brazil: Krohne, a multinational company that manufactures magnetic, ultrasonic and mass ow meters, as well as a full line of level meters.
Established in 1996, KCI Krohne Conaut Instrumentao, is a joint venture between Krohne and Conaut in Brazil. It was initially created for the manufacturing of magnetic ow meters and nowadays also manufactures ultrasonic ow meters. Today, KCI exports to USA, Europe and South America approximately 60% of its production.
Established in 2002, Conaut Services is located in Maca Rio de Janeiro. Its activities are oriented mainly to oil and gas area, and it also cares others branches of the industry. This unit has the only two laboratories for oil and water ow certied by INMETRO, in the state of Rio de Janeiro
Electromagnetic ow meter
RUBBER/ POLYURETHANE COATING Optiux 2000 FEP/PFA COATING Optiux 4000
Complete line of electromagnetic ow meters. Diameters from 2.5mm to 3000mm (1/10 until 120) Coating in FEP, PFA, PTFE, ETFE (Tefzel), Rubber (neoprene, ebonite and etc), polyurethane and ceramics. Accuracy class: from 0,5% to 0,15% of V.M. Optional meter for application in sanitation with pipes treated with resin in the plant (IP68 protection) and the electronic part is totally remote. For use in classied area. Meters for sanitation application with 3A approbation. Special meter for application in partial full pipes.
News
IFC Easy installation Application diagnosis Large graphical display Easy operation Low cost
IFC 300 F
MAGNETIC METER WITH BATTERY (WITH 15 YEARS AUTONOMY) Waterux IFC 300 W IFC 300 C
Local programming in the display or remote mode through available communication protocols. Many types of diagnosis with parameters for performance control of the process and of the meter. Integral assembling (compact), remote in wall, remote in local or in rack 19. Optional stainless steel involucre for use in marine environment. Optional Virtual Grounding. A patented system by Krohne, where the electronic part of the converter simulates grounding signal, that makes not necessary the use of grounding rings. It is ideal for application with highly corrosive uids.
Models UFM 3030, UFM 530 e UFM500 Accuracy 0,5% of V.M. Bi-directional measurement Diameters from 25mm to 3000 mm (1 to 120) Option for application in classied area and marine environment Model OPTISONIC 6300 - Fixed Clamp-On Fixed application in pipes or portable. Without contact with uids, the sensors are installed in the pipes wall (clamp-on) Accuracy 1% to 3% of V.M. Bi-directional measurement Diameters from 15mm to 4000mm (1/2 to 160) Option for application in classied area (except for portable meter) Model OPTISONIC 6400 - Portable Clamp-On Fixed application in pipes or portable. Without contact with uids, the sensors are installed in the pipes wall (clamp-on) Accuracy 1% to 3% of V.M. Bi-directional measurement Diameters from 15mm to 4000mm (1/2 to 160) Model ALTOSONIC III Accuracy 0,20% of V.M. Approved by INMETRO for Custody Transfer Bi-directional measurement Diameters from 50mm to 1000 mm (2 to 40) Option for application in classied area and marine environment Model ALTOSONIC V Accuracy 0,15% from V.M. Approved by INMETRO for Custody Transfer Bi-directional measurement Diameters from 100mm to 1000 mm (4 to 40) Option for application in classied area and marine environment Model UFM 830 BR Sensors are soldered directly to the pipe Installation with the line load. Does not depend on the line stops operation. The meter allows retrotting on to existing pipelines without interrupting the process. Versions with one measurement channel (accuracy 1% of V.M.) and with two measurements channels (accuracy 1% of V.M.) Bi-directional measurement Diameters from 100mm
Optisonic 6300
Altosonic V
Altosonic III
UFM 830 BR
News
sensor
Vortex ow meter
Accuracy from 0.75% until 1% of VM. Low charge loss. Wet parts in Stainless Steel AISI 316L and Hastelloy C. System with 2-wires. Application in liquid and gas measurement. Compensation option for temperature and pressure integrated to the sensor
OPTISWIRL 4070
Application in gas measurement. Operation principle by passage time. Option for application in classied area and marine environment Bi-directional measurement Without charge lost Model ALTOSONIC V12 Accuracy 1% of V.M. Without charge loss Bi-directional measurement Diameters from 100mm to 600 mm (4 to 24) Option for application in classied area and marine environment Operation principle by passage time Application in gas measurement Model OPTISONIC 7300
Optisonic 7300
Mass Flowmeters
Acting principle by Coriolis effect Measurement of mass ow and total; volumetric ow and total; density; temperature, Brix, INPM and general concentration Application in liquid and gas measurement. Bi-directional measurement Option for application in classied area, marine environment and custody transfer Accuracy 0.1% and 0.2% of V.M. Model OPTIMASS 1000 Two parallel straight pipes with low loss of charge Internal diameter from 15mm until 50mm Wet parts in AISI 316L Model OPTIMASS 2000 Two parallel straight pipes with low loss of charge Internal diameter from 100mm to 250mm Wet parts in AISI 316L Model OPTIMASS 3000 Pipes curved in Z form for low ow Internal diameter: 1mm, 3mm and 4 mm Wet parts in AISI318L and Hastealloy C22 Model OPTIMASS 7000 One straight pipe with low charge loss. Internal diameter from 6mm until 80 mm. Wet parts in AISI318L, Hastealloy C22, Titanium and Tantalus Model OPTIMASS 8000 Two curved pipes in parallel. Internal diameter from 15mm until 100 mm. Wet parts in AISI316L and Hastealloy C22. Special application with temperatures from -180 C until 240C.
Optimass 3000
Optimass 1000
News
Optimass 2000
Optimass 7000
Optimass 8000
Mod. 250
Mod. 400
Mod. 420
Mod. 440
Mod. DK 32
Mod. 010
Mod. 016
Mod. 019 Diameter from to 6. Pressure until 6 kgf/cm. Practical and economic.
Mod. 018
Diameter from 2 to 8. Pressure until 10 kgf/cm. With pneumatic retarder. Optional: without pneumatic retarder.
Mod. 017
Diameter from 1 to 12. Installation wafer type. Vertical or horizontal. Ascendant or descendant. Liquid or gaseous. Optional alarms.
Diameters: , and (with turbine) or to 6 (with or without vane). Threaded connections (all) or anged (with or without vane).
Mod. 092
Built with transparent body (with turbine), single or double window (with or without vane).
Mod. 091
Level indicators
With magnetic transmission
Level indicators
Mod. 050
Modelo 810
Reective, transparent or tubular. Pressure until 220 kgf/cm. Temperature until 400C. Optional: mica protection, acrylic illumination, anti-freezing extension. Valves off-set type. Several materials. Illuminator explosion proof type.
Indication through bi-colored vanes or glass pipe with external indicator without contact with the uid. Total safety. Pressure until 200 kgf/cm. Temperature until 300C. Optional: external alarms and output 4~20mA Heating or cooling jacket.
Level indicators
Mod. 059 ALB-III
Model 056 with displacement system Buoyancy principle. Low and high pressures. Until 15m. Optional: alarms, output of 4~20mA Model 059 External rule type Adequate for large tanks or reservoirs. Simple and strong. Accessories: external alarms. Optional manufacturing attends ANP norm. Model 059 ALB-III with contacts Ideal for oil reservoir, residues boxes and API boxes. Signalizes 04 level points (adjustable)
Mod. 056
Mod. 059
Model 302
Model 305
10
Mod. 032
Temperature up to 165C. Tank, columns and reservoir pressurized or nonpressurized. Maximum length 1 meter. Actuation for one point.
Mod. 024
11
Mod. 049
12
Running principle by modulated frequency FMCW. Application in level measurement in liquid and solid.
13
EEx Monitor
14
Addressable Devices
Local Alarm
Ancillary Devices
Addressable Detectors
Detection system and re alarm It is a control unit for protecting a single area, low cost and versatile, who can oversee a system of re suppression. Can be connected up to 20 devices for each circuit (zone), panels are provided for 2 to 8 zones.
The 6000 series of re detectors uses proprietary protocol. Communication speed, electromagnetic compatibility and ease of use.
15
Founded in 2002, CONAUT Services (Maca - RJ) was initially created to serve the oil and gas industry. CONAUT Services expanded its activities, and today is acting in all industrial elds.
Measuring Station (EMED) Small-and-simple up to large-and-comprehensive metering solutions Custody-transfer solutions Turnkey and tailor-made solutions Proving systems solutions Complete revamping Best meter technology Secure operation with guaranteed maximum data integrity Easy human interface machine operations Highest performance achieved, according the largest international rules
16
Laboratories in Maca - RJ
Oil Laboratory
A CONAUT inaugurated in 2008 more two laboratories for calibration with oil and water of meters from 25 to 300mm, certied by INMETRO and RBC.
Water Laboratory
17
Laboratories in Embu - SP
Calibration tower
Tower height: 41m Tower diameter: 3.85 m Tower volume: 445 m3 Reservoir volume: 1 000 000 liters Reached ows From 10 to 49 000 m3/h.
18
Flow Laboratory
CONAUT has an ow laboratory structure similar to the biggest around the world, CONAUT attends meters with diameters between 2,5mm to 3 000 mm. The Conauts calibration tower, in partnership with INMETRO, is the biggest one in the Americas. It makes possible the calibration process of meters until 3000mm and with maximum ow of 49.000 m3/h. The internal laboratory, located in Embu-SP, has 6 interchangeable lines, a 150 000 liters reservoir and a scale for 60 tons, what makes possible the calibration in meters from 2.5 to 1.500mm (60).
Level Laboratory
News
CONAUT has inaugurated the rst laboratory for level meters in Brazil, certied by INMETRO. Now it is possible to calibrate Radar and Ultrasonic level meters in accordance to international standards
19
Matriz: Estrada Louis Pasteur, 230 - CEP 06835-080 - Embu - SP - Brasil Tel: (11) 4785-2700 Filial RJ: Av. Mal. Cmara, 160 - Sala 1009 - CEP 20020-080 - Rio de Janeiro - RJ Tel: (21) 2220-7881 Conaut Services: Rua Internacional n 309 - Granjas dos Cavaleiros - CEP 27930-075 - Maca - RJ Tel: (22) 2106-0250 www.conaut.com.br conaut@conaut.com.br Depto. Comercial: vendas@conaut.com.br