Feeders Cross Section Calculation FCSC
- .................................................................................................
.....................................................................
- )(
..................
- ....................................................................
..............................
- ................................................................
- ....
........................................................................................
- ...............................
- ......................................................................................
- ...................................................................................
00963 94 571281
Feeders Cross Section Calculation FCSC
-:
:
...
:
: .
:
:
pvc 70C 85C
XLPE Cross Linked Polyethylene
90C
.
:
. . ) (
.
:
"
" .
.
)
( .
00963 94 571281
I2 1.45 Iz
)(1
IB In Iz
:
: IB ) (.
: In . Ir In
.Ir = In
) In Ir =(0.7-1
Ir =(0.4-1) In Ir
.
:Iz :
)( :I2 ) (.
:Isc
:ISCB
) ( ) (
00963 94 571281
1.45
IZ
ISC
ISCB
1.45 IZ
IZ
IB
In
I2
I2
In
In Ir, Ir
) (
)(1
) (
.
.
MCB High Rupturing Capcity HRC
) (
) (
) (
) ( ) (
.
:
.
.
. Solenoids
00963 94 571281
.Safety
) ( ) (
:
.35 C
. C
. m
. km / w
flat
.
.
. IEC287,
) ( ).(
00963 94 571281
)(
Current carrying capacity
Single core cables with copper conductor,
PVC 70 C Insulated and PVC sheathed, 0.6/1 K V
PVC
70 C PVC ,/1 kv
00963 94 571281
)(
Current carrying capacity
Three and four core cables with copper conductor,
PVC 70 C Insulated and PVC sheathed, 0.6/1 K V
pvc
70 C PVC /1 kv
00963 94 571281
)(3
Current carrying capacity
Single core cables with copper conductors,
PVC 85 C Insulated and PVC sheathed, 0.6/1 K V
PVC
85 C PVC ,/1 kv
00963 94 571281
)(4
Current carrying capacity
Three and four core cables with copper conductors,
PVC 85 C Insulated and PVC sheathed, 0.6/1 K V
PVC
85 C PVC ,/1 kv
00963 94 571281
)(5
Current carrying capacity
Single core cables with copper conductors,
of XLPE Insulated and PVC sheathed, 0.6/1 K V
XLPE
PVC ,/1 kv
00963 94 571281
)(6
Current carrying capacity
Three and four core cables with copper conductors,
XLPE Insulated and PVC sheathed, 0.6/1 K V
XLPE
PVC ,/1 kv
00963 94 571281
)(7
)(8
Cables laid direct in ground
Rating factors for variation in depth of burial
)(to centre of cable in the trefoil group of cables
0.5m
00963 94 571281
(9)
Cables laid direct in ground
Rating factors for variation in thermal resitivity of soil (average values)
(11)
00963 94 571281
00963 94 571281
)(
DIN C
00963 94 571281
00963 94 571281
) ( :
- ) ( :
) ( :
) ( )PE (Protective Earth
- )(
)(
)( VDE 100 Part
mm
) (
potential equalization bonding :
0.5 x : )( 6 mm2 ) 2.5 mm 2 4 mm 2 (:
1 x :
0.5 x : )(
00963 94 571281
- :
.
/ .
.
.
:
Prospective Short Circuit Current PSCC .
. . .
.
PSCC
.
00963 94 571281
PSCC
.
1-4 :
:
- R upstream
:
]R = R + R + R + ....[m
t
- t
upstream
] t = 1 + 2 + 3 + ....[m
- :
U
3.Z t
= I SC
:
S
]100 [ KA
3 U sc .U
] U [V
] Z t = Rt 2 + t 2 [ m
= I SC
: phase to phase
:
.
]S [ kVA
U sc
:
:
) (
00963 94 571281
] [m
1 = Z1 sin 103 Z1
]R[m
R1 = Z1 cos 103
cos = 0.15
sin = 0.98
R1 = 0.151
U2
Psc
Z1:
= Z1
UPSTREAM
] 250 500[MVA
: P :
Z :
sc
) (
HV
U = 380V
] [ m
Psc
][MVA
U = 420V
]R [ m
] [ m
]R [ m
R
2 = Z 22 R22
U SC U 2
100 S
%
= Z2
: U SC
Wc U
103
S2
2
] Wc [W
= R2
] : S [ kVA
00963 94 571281
] [m
]R[m
:
3 = 0.15 L
:
3 = 0.2L
]L [ m
50 mm2
:
0.08 .096
m/m
L= 1m
0.18
0.15
L
R3 =
s
= 1 .mm 2 / m
45
= 22.3 m.mm 2 / m
1
= .mm 2 / m
27
= 37 m.mm 2 / m
][mm2
]f[Hz
70 C
:s
s = 50 5mm 2
50 60
%
]f[Hz
80 5
100 5
:
/
: /
:
R1 R2
R1 + R2
= R3
3 = 1 2
1 + 2
L
s
R4 =
s : mm 2
] X 5 = 0.15 [ m / pole
R5 0
PSCC
. ) (
. ) (
.
00963 94 571281
00963 94 571281
Software
Ecodial GROUPE SCHNEIDER
DOCWIN ABB.
2-4 :
.
00963 94 571281
.
:
.
.
) ( .
mm2 . sec
) I2t
(
.
" :
PSCC
" .
) ( k=115 /MCB
. MCB
/ ) (
00963 94 571281
Overheating
.
.
.
00963 94 571281
3-4 :
) ( :
upstream A )( B .A .
cascading
.A
:
ISC B ) (
50mm2 11m
A
28kA .30kA
B .19kA
A
00963 94 571281
()
ISC at a point downstream, in terms of a known upstream fault-current value and the length and c.s.a.
of the intervening conductors, in 230/400 v 3-phase system.
Note: for a 3-phase system having 230 v between phases, divide the above lengths by 3 = 1.732
00963 94 571281
-5 :
"
" .
.
.
1-5 :
70 C 1/45
:
00963 94 571281
00963 94 571281
00963 94 571281
- 6 :
150 kW
1000 KVA
):(
PSC= 500 MVA
S= 1000 kVA
20KV/380 V
USC=5%, WC=15500 W
------------------------- XLPE
35 C
------------------------- 5 80 x 5 mm2
------------------------- PVC
80 cm
30 C
)(
------------------------- ) ( P = 150 kW
0.8
:
-
-
-
- A
- B
00963 94 571281
:
:
- :
) (a IB = 1.52 S = 1520 [A] :
:
:
) ( 300 mm2 740A
:
K = 1.05 x 0.7 x 0.95 0.7
) ( :
In = 1600 A
00963 94 571281
00963 94 571281
) ( :
:
PVC :
- :
- R :
]1 = 0.283 [ m
]R1 = 0.043 [ m
:
- IEC 230/400V
220/380 V
.220/380 V .
Wc
:
00963 94 571281
00963 94 571281
00963 94 571281