NO ALARM

7600 BCF FAULTY

INFORMATION
Power unit is probably broken. Fault in the chain between power unit and MHA. BSS synchronisation failed. Difference between PCM and base station frequency reference.

7601 BCF OPERATION DEGRADED

Incompatible unit presence detected in the BTS. Rx levels differ too much between main and diversity antennas. Power unit input voltage fault. Fault in the chain between power unit and MHA. 1st branch LNA in dual variable gain duplex unit is faulty. 2nd branch LNA in dual variable gain duplex unit is faulty.

7602 BCF NOTIFICATION

Power unit temperature is dangerously high. Mismatch between BSC/MMI configuration file and the actual Cooling fan is broken. No connection to power unit. TSxx rack I2C bus is jammed. Common rack EAC I2C bus is jammed. Fan unit is broken.

7603 BTS FAULTY

There is disturbance in the serial DL bus or bus is broken Antenna connection faulty. The RF receiver frequency hopping synthesizer 1 is not locked. Fault in the chain between power unit and MHA. Master TRX detected that connection to slave TRX is lost. BOI or TRX has detected a failure in the incoming frame clock

7604 BTS OPERATION DEGRADED

2nd branch LNA in dual variable gain duplex unit is faulty. 1st branch LNA in dual variable gain duplex unit is faulty. Performance is degraded in 2nd branch dual variable gain Performance is degraded in 1st branch dual variable gain Fault in the chain between power unit and MHA. TRX test result antenna connection faulty. No connection to dual variable gain duplex unit.

7606 TRX FAULTY

Antenna connection faulty. BOI detected that connection to TRX is lost. Failure detected during TRX configuring. The transmitter output power is too low. The transmitter output power has dropped at least 3 dB. The RF transmitter frequency hopping synthesizer 2 is not The RF transmitter frequency hopping synthesizer 1 is not Non EDGE TRX device type used accidentally in Edge Capable The RF receiver frequency hopping synthesizer 2 is not locked. The transmitter output power has dropped at least 3 dB. Interface problems between O&M and EQDSP software or EQDSP The system clock (26MHz) is not locked. Master TRX detected that connection to slave TRX is lost. The transmitter output of TRX is overdriven TSxx temperature is dangerously high.

7607 TRX OPERATION DEGRADED

Rx levels differ too much between main and diversity antennas. No connection to dual variable gain duplex unit. TRX I2C -bus is jammed.

7608 TRX NOTIFICATION

TSxx has lost connection to temperature sensor. BB2 has lost connection to temperature sensor. Impossible to execute TRX loop.

7609 TRE FAULTY 7615 RTS IS IN TEST USE

BOI detected that connection to transmission unit lost. Master TRX detected that connection to transmission unit lost.

7616 OSCILLATOR ADJUSTING TEMPORARILY INTERRUPTED Oven oscillator adjustment function interrupted. 7622 CABINET OPEN 7700 BTS OMU INITIALIZATION 7701 BCF INITIALIZATION 7701 BCF INITIALIZATION 7704 PCM FAILURE 7705 LAPD FAILURE 7706 BTS O&M LINK FAILURE 7711 WORKING FULL RATE TCH RATIO BELOW THRESHOLD 7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD 7715 CONTINUOUS RESTARTS OF BCF/TRX 7717 WORKING HALF RATE TCH RATIO BELOW THRESHOLD 7717 WORKING HALF RATE TCH RATIO BELOW THRESHOLD 7724 CONFLICT BETWEEN BSS RADIO NETWORK DATABASE AND CALL CONTROL 7725 TRAFFIC CHANNEL ACTIVATION FAILURE 7727 TRAFFIC CHANNEL NUMBER DECREASED 7728 OBJECT OUT OF USE BECAUSE OF ERROR IN BTS INTERNAL DIAGNOSTICS 7729 RADIO NETWORK RECOVERY FAILED 7730 CONFIGURATION OF BCF FAILED 7731 BCF SW PACKAGE MAY BE DIFFERENT AS DEFINED AS A DEFAULT IN BSC 7734 BCCH IS NOT AT PREFERRED BCCH TRX 7735 TRX TEST FAILED 7737 INCONSISTENT DATA IN RADIO RESOURCE MANAGEMENT STATE FILES 7738 BTS WITH NO TRANSACTIONS Cabinet cover is open.

1 2 3 10

7740 BEATING BTS ALARM 7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD 7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD 7744 EXCESSIVE TCH INTERFERENCE 7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD 7746 CH CONGESTION IN CELL ABOVE DEFINED THRESHOLD 7767 BCCH MISSING 7769 FAILURE IN UPDATING CELL SPECIFIC PARAMETERS TO PCU 7801 MMI CONNECTED TO BASE STATION 7995 MAINS BREAKDOWN WITH BATTERY BACK-UP 8000 POWER SUPPLY FAULT 8020 BLOCKED FROM USE 8045 NO OUTGOING SIGNAL 8050 LOSS OF INCOMING 2M SIGNAL 8060 NO INCOMING RADIO SIGNAL 8064 ALARM SIGNAL (AIS) IS RECEIVED 8066 ALARM INDICATION SIGNAL (AIS) RECEIVED 8081 LOSS OF FRAME ALIGNMENT 8086 LOSS OF CRC MULTIFRAME ALIGNMENT 8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3 8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6 8112 FREQUENCY ERROR

8137 OSCILLATOR FAULT 8139 SUBRACK HAS MISSING UNITS 8141 FORCED CONTROL ON 8142 INSTALLATION ERROR 8150 FAULT IN UNIT 8165 REAL TIME LOST 8179 FAR-END ALARM 8186 CONFIGURATION ERROR 8202 LOSS OF SUPERVISION CONNECTION 8221 VERSION MISMATCH

TO
FIELD BTS FIELD BTS FIELD BTS FIELD TRANS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS FIELD BTS

FIELD BTS DISTURBANCE FIELD BTS FIELD BTS DISTURBANCE DISTURBANCE DISTURBANCE FIELD TRANS FIELD TRANS FIELD TRANS RF & BSS RF & BSS FIELD BTS & BSS RF & BSS RF & BSS BSS BSS & FIELD BSS & FIELD FIELD FILED &BSS FIELD & BSS BSS BSS BSS BSS FIELD BTS & BSS FIELD BTS & BSS FIELD BTS & BSS BSS FIELD TRANS RF & BSS RF & BSS FIELD & BSS & RF RF & BSS RF & BSS RF & BSS FIELR BTS BSS DISTURBANCE EXT ALARM FIELD TRNAS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS

FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS FIELD TRANS

ACTION
CHECK THE PWSB &BACK PLANE & JACK IN &OUT ELSE CHANGE THE PWSB

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION CHECK SYNC CABLE & AUTO DETECTION SETTINGS. SYNCHRANISATION SET UP VERIFICATION ON THE SITE IF IT IS CORRECT GO UP BSC & CHECK IN ALL THE SITES F
METRO SITE &THOUGH ALL TRXS ARE SHOWING THE ALARM GENERATED .

NEEDS SITE VISIT


CHECK THE PWSB &BACK PLANE & JACK IN &OUT ELSE CHANGE THE PWSB

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


REPLACING OF DVGA REPLACING OF DVGA INCASE OF OUTDOOR BTS CHECK THE DOOR FAN FUNCTIONALITY HARDWARE CHECK UP & VERIFICATION CHECK THE COOLING FAN CHECK THE PWSB &BACK PLANE & JACK IN &OUT ELSE CHANGE THE PWSB METRO SITE &THOUGH ALL TRXS ARE SHOWING THE ALARM GENERATED . CHECK FOR THE FAN UNITS NO TRXS IN THE SLOT ELSE THE SLOT IS FAULTTY VSWR ISSUE NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


IN METRO FACING THIS PB NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. REPLACING OF DVGA REPLACING OF DVGA REPLACING OF DVGA REPLACING OF DVGA

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


VSWR ISSUE REPLACING OF DVGA VSWR ISSUE AFTER RESETTING TRX THE PB AGAIN ARAISES WHILE THE DOWN STE COMES UP NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. NEEDS TRX CHANGE. NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. AFTER AHOP DISABLE & SECTOR RESET T There is disturbance in the serial DL bus or bus is broken NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. NEEDS TRX CHANGE. NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F. IN METRO FACING THIS PB NEEDS TRX CHANGE. CHCEK FOR THE FAN UNITS

NEEDS SITE VISIT


REPLACING OF DVGA METRO SITE &THOUGH ALL TRXS ARE SHOWING THE ALARM GENERATED . CHCEK FOR THE FAN UNITS CHCEK FOR THE FAN UNITS NEEDS TRX CHANGE

BOI OR RRI MAY FAULTY NEEDS JACK IN & OUT UNITL THE TRANSMISSION UNIT DETECTED NEEDS BOI /VIFA CHANE

SITE MAY BE DOWN OR NEEDS SECTOR RESTART RESET THE CHANNELS &CHECK RESET THE CHANNELS &CHECK NEEDS THE TRX CHANGE NEEDS BCF OR SITE RESET.MAY BE SITE DOWN NEEDS BCF OR SITE RESET.MAY BE SITE DOWN ACTIVATE ON DEFAULT PACKAGE CHECK , OBSERVE & CHANGE NEEDS SITE RESET OR CLEAR THE ALARM NEEDS SECOTR RESET. IS DUE TO HUGH CALLS IN THE SECTORS

DUE TO CONTINOUS MEDIA FLUUCTATION / CONTINOUS ALARM REPEATATION

NEEDS BOI CHANGE

SITE MAY DOWN GIVE A SECTOR REST

CHECK RRI / ODU POWER SUPPLY CC BANK ALARM

ENABLE CRC / DISABLE THE CHANNEL

SYNCHRANISATION SET UP VERIFICATION

FIND OUT RRI / ODU & CHANGE CHANGE THE ODU DUE TO CRC PB CHANGE THE RRI/ODU /BOTH REMOVE THE UNNECSSARY SUPERVISARY CHANNELS.

3RD LINE SUPPORT COMMENTS

ECK IN ALL THE SITES FOR SYNCRANISATION