Você está na página 1de 12

Manual de Operao e

Instalao
Calha Parshall
MEDIDOR DE VAZO EM CANAIS ABERTOS
Cd: 073AA-025-122M Rev. C

Julho / 2009

Incontrol S/A.
Rua Joo Serrano, 250 Bairro do Limo So Paulo SP CEP 02551-060
Fone: (11) 3488-8999 FAX: (11) 3488-8980
e-mail: assistenciatecnica@levelcontrol.com.br

Calha Parshall

Incontrol

NDICE
1.INTRODUO........................................................................................................................................3
2.PRINCPIO DE FUNCIONAMENTO.......................................................................................................4
3.CONSTRUO......................................................................................................................................5
4.SELEO DE TAMANHO.....................................................................................................................9
5.INSTALAO........................................................................................................................................9
6.OPERAO.........................................................................................................................................10
7.MANUTENO....................................................................................................................................10
8.FRMULAS E TABELAS....................................................................................................................11
9.MEDIDOR DE NVEL............................................................................................................................11
10.CERTIFICADO DE GARANTIA..........................................................................................................12

Aviso:
Este manual poder ser alterado sem prvio aviso, pois os dados desse
documento so revisados periodicamente e as correes necessrias sero
consideradas nas prximas verses. Agradecemos por qualquer tipo de
sugesto que venha contribuir para a melhora deste documento.
_______________________________________________________________________
2

Calha Parshall

Incontrol

1. INTRODUO
O medidor Parshall desenvolvido pelo engenheiro Ralph L. Parshall, na dcada de
1920, nos Estados Unidos, uma melhoria realizada no projeto de calha Venturi.
Desenvolvido inicialmente para aplicaes em irrigao, hoje em dia utilizado
frequentemente nas aplicaes industriais e de saneamento.

_______________________________________________________________________
3

Calha Parshall

Incontrol

2. PRINCPIO DE FUNCIONAMENTO
O medidor Parshall, tambm conhecido por Calha Parshall, um medidor de vazo
para canais abertos. A calha constituda de uma estrutura com paredes verticais,
possuindo na entrada um trecho convergente (0-1), um trecho contrado em declive de
seo constante (1-2), e na sada um trecho divergente em aclive (2-3).

Figura 1
O trecho convergente, tambm chamado de crista, produz um nvel (Ha), no lquido
medido, que est diretamente relacionado com a vazo.
Com auxlio de um medidor de nvel externo adequado, podemos obter leituras de
vazo com uma boa preciso.

_______________________________________________________________________
4

Calha Parshall

Incontrol

3. CONSTRUO
Os tamanhos das Calhas Parshall so designados pela largura da garganta (trecho
contrado) e podem ser construdos no campo ou fabricados com fibra de vidro, ao
carbono revestido, ao inox ou concreto.
A norma vigente no Brasil a norma NBR/ISO9826:2008. Porm, tendo em vista ser
uma norma relativamente nova, a grande maioria das calhas Parshall existentes
obedecem norma ASTM 1941:1975.
Neste manual apresentamos os dados das duas normas. Portanto, verificar por qual
norma foi fabricada a sua calha para utilizar corretamente os dados aqui
apresentados.
Os tamanhos disponveis so os apresentados nas tabelas abaixo:
3.1

NORMA NBR/ISO 9826:2008

As tabelas a seguir apresentam, respectivamente, as caractersticas de vazo das


calhas Parshall de pequenas e grandes dimenses:

Calha
Parshall
n
1
1

Largura
da
Garganta
b
(m)

Equao da
vazo1)

0,152

Intervalo de
Altura

ha

Q=Ch a
(m/s)

(m)

Intervalo da
Vazo2)
Q
(x10-3 m3/s)

min.

max.

min.

max.

Limite
modular

Razo de
Submergncia

(experimental) (recomendado)

0,381h

1,580
a

0,03

0,45

1,5

100

0,55

0,6

1,513
a

0,250

0,561h

0,03

0,60

3,0

250

0,6

0,300

0,679h1,521
a

0,03

0,75

3,5

400

0,62

0,6

0,450

1,038h

1,537
a

0,03

0,75

4,5

630

0,64

0,6

1,403h

1,548
a

0,05

0,75

12,5

850

0,66

0,6

1,772h

1,557
a

0,06

0,75

25,0

1100

0,67

0,6

1,565
a

0,06

0,75

30,0

1250

0,68

0,6

1,569
a

0,06

0,80

30,0

1500

0,7

1,577
a

0,06

0,80

35,0

2000

0,70

0,7

1,586
a

0,06

0,80

45,0

2500

0,72

0,7

1,593
a

4
5
6
7
8
9
10

0,600
0,750
0,900
1,000
1,200
1,500

2,147 h
2,397 h
2,904 h
3,668h

11

1,800

4,440 h

0,08

0,80

80,0

3000

0,74

0,7

12

2,100

5,222h1,599
a

0,08

0,80

95,0

3600

0,76

0,7

2,400

1,605
a

0,08

0,80

100,0

4000

0,78

0,7

13

6,004h

1) C=C D b3,279
onde
C D o coeficiente de descarga
n um expoente dependente de b
2) Valores arredondados

Tabela1

_______________________________________________________________________
5

Calha Parshall

Calha
Parshall
n
1
14
15
16

Incontrol

Largura
da
Garganta
b
(m)

Equao da
vazo1)

3,05
3,68
4,57

Intervalo de
Altura

ha

Q=C 1 h 1,6
a

(m)

(m/s)

Intervalo da
Vazo2)
Q
(m3/s)

Razo de
Submergncia

Coeficiente de
Submergncia
(Fator de Correo)

min.

max.

min.

max.

(recomendado)

Cs

7,463h

1,6
a

0,09

1,07

0,16

8,28

0,80

1,0

8,859h

1,6
a

0,09

1,37

0,19

14,68

0,80

1,2

10,96h

1,6
a

0,09

1,67

0,23

25,04

0,80

1,5

1,6
a

17

6,10

14,45h

0,09

1,83

0,31

37,97

0,80

2,0

18

7,62

17,94h1,6
a

0,09

1,83

0,38

47,16

0,80

2,5

9,14

1,6
a

0,09

1,83

0,46

56,33

0,80

3,0

1,6
a

0,09

1,83

0,60

74,70

0,80

4,0

1,6
a

0,09

1,83

0,75

93,04

0,80

5,0

19
20
21

21,44 h

12,19

28,43 h

15,24

35,41h

Tabela 2

I1

ha

I2

hb

b2

b1

Ia

hP1

hP2

ha

hC

Ie

_______________________________________________________________________
6

Calha Parshall

Incontrol
Figura 2

Calha
Parshall
n
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21

Garganta
b
0,152
0,250
0,300
0,450
0,600
0,750
0,900
1,000
1,200
1,500
1,800
2,100
2,400
3,050
3,660
4,570
6,100
7,620
9,140
12,190
15,240

l
0,305
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,600
0,910
0,910
1,220
1,830
1,830
1,830
1,830
1,830

Seo de Entrada
hp1
0,115
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,230
0,343
0,343
0,457
0,686
0,686
0,686
0,686
0,686

b1
0,400
0,780
0,840
1,020
1,200
1,380
1,560
1,680
1,920
2,280
2,640
3,000
3,380
4,760
5,610
7,620
9,140
10,670
12,310
15,480
18,530

l1
0,610
1,325
1,350
1,425
1,500
1,575
1,650
1,700
1,800
1,950
2,100
2,250
2,400
4,270
4,880
7,620
7,620
7,620
7,930
8,230
8,230

le
0,622
1,352
1,377
1,454
1,530
1,607
1,683
1,734
1,836
1,989
2,142
2,295
2,448
-

Seo de Sada
la
0,415
0,900
0,920
0,967
1,020
1,074
1,121
1,181
1,227
1,329
1,427
1,534
1,632
1,830
2,030
2,340
2,840
3,350
3,880
4,880
5,890

h2
0,390
0,550
0,600
0,750
0,900
1,050
1,200
1,300
1,500
1,800
2,100
2,400
2,700
3,660
4,470
5,590
7,320
8,940
10,570
13,820
17,270

l2
0,610
0,920
0,920
0,920
0,920
0,920
0,920
0,920
0,920
0,920
0,920
0,920
0,920
1,830
2,440
3,050
3,660
3,960
4,270
4,880
6,100

hp2
0,012
0,072
0,072
0,072
0,072
0,072
0,072
0,072
0,072
0,072
0,072
0,072
0,072
0,152
0,152
0,203
0,305
0,305
0,305
0,305
0,305

Tabela 3
3.2

NORMA ASTM 1941:1975


Largura da
Garganta

Capacidade de Vazo

Min

Max

(inch)

(m3/h)

(m3/h)

1.02

19.4

2.04

47.9

3.06

115

5.10

398

9.17

907

12

11.2

1641

18

15.3

2508

24

42.8

3374

36

62.2

5138

48

132

6922

60

163

8726

72

265

10551

84

306

12376

96

357

14221

Tabela 4
_______________________________________________________________________
7

Altura
da
Parede
hc
0,600
0,800
0,950
0,950
0,950
0,950
0,950
1,000
1,000
1,000
1,000
1,000
1,000
1,220
1,520
1,830
2,130
2,130
2,130
2,130
2,130

Calha Parshall

Incontrol

Figura 3
DIMENSES
T
G
K

2/3A

[inch]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

[mm]

1
2
3
6
9
12
18
24
36
48
60
72
84
96

363
414
467
621
880
1372
1448
1524
1677
1829
1981
2134
2286
2438

242
276
311
414
587
914
965
1016
1118
1219
1321
1423
1524
1625

356
406
457
610
864
1343
1419
1495
1645
1794
1943
2092
2242
2391

93
135
178
394
381
610
762
914
1219
1524
1829
2134
2438
2743

168
214
259
397
575
845
1026
1207
1572
1937
2302
2667
3032
3397

229
254
610
610
762
914
914
914
914
914
914
914
914
914

76.2
114
152
305
305
610
610
610
610
610
610
610
610
610

203
254
305
610
752
914
914
914
914
914
914
914
914
914

19.0
22.2
25.4
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2

305
305
381
381
381
381
457
457
457
457
457

28.6
42.9
57.2
114.3
114.3
228.6
228.6
228.6
228.6
228.6
228.6
228.6
228.6
228.6

902
1080
1492
1676
1854
2223
2711
3080
3442
3810
4172

406
406
508
508
508
508
610
610
610
610
610

7.94
9.52
25.4
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8
50.8

12.7
25.4
38.1
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2
76.2

Tabela 5
Obs.: As medidas correspondentes calhas Parshall com largura de garganta de 1 e
2 no constam na norma ASTM 1941:1975, embora seus valores sejam
determinados matematicamente baseados na mesma.

_______________________________________________________________________
8

Calha Parshall

Incontrol

4. SELEO DE TAMANHO
Para a seleo do tamanho do medidor Parshall, devem ser conhecidos os seguintes
dados:
a-)

largura do canal na montante e na jusante;

b-)

vazes mxima e mnima;

c-)

profundidade da gua no canal;

d-)

perda de carga admissvel;

e-)

previso para vazes futuras.

As seguintes recomendaes devem ser levadas em conta:


a-)

Utilizar sempre escoamento livre, pois assim necessrio apenas um medidor


de nvel no trecho convergente;

b-)

Para se obter escoamento livre as seguintes condies devem ser obedecidas:

Onde:

Norma NBR/ISO 9826:2008:


1-)

relao hb/ ha = 0,6 para medidores at 0,90 m;

2-)

relao hb/ ha = 0,7 para medidores at 2,40 m;

3-)

relao hb/ ha = 0,8 para medidores at 15,24 m.

Norma ASTM 1941:1975:


1-)

relao Hb/Ha < 0,6 para medidores at 22;

2-)

relao Hb/Ha < 0,7 para medidores de 30 a 40.

ha e Ha correspondem altura da lmina de gua a montante.


hb e Hb - correspondem altura da lmina de gua a jusante.

c-)

Carga total na crista do medidor no superior carga total na seo de entrada;

d-)

Perda de carga no medidor no superior carga disponvel;

e-)

Caso tenha afogamento, obedecer os mximos citados anteriormente (item b).


Neste caso ser necessrio instalar um medidor de nvel tambm no trecho
contrado;

f-)

Obedecidas todas as condies citadas, escolher a calha de menor largura.

5. INSTALAO
Algumas condies bsicas de instalao devem ser obedecidas:
a-)

O medidor Parshall deve ser instalado precedido montante ou por um


reservatrio de grande dimenso, onde a velocidade seja sensivelmente nula, ou
por um trecho de canal prismtico onde o escoamento seja uniforme;

b-)

O medidor deve estar instalado com o canal tanto na montante como na jusante;

_______________________________________________________________________
9

Calha Parshall

Incontrol

c-)

O medidor deve ser alinhado longe o suficiente da comporta ou curvas, para que
o escoamento na regio da entrada do medidor seja uniforme e completamente
livre de turbulncias, ondas ou vrtices;

d-)

A crista do medidor deve estar rigorosamente em nvel a fim de assegurar a


mesma vazo para o mesmo nvel ao longo da largura do medidor;

e-)

As paredes laterais do trecho contrado devem estar paralelas e verticais;

f-)

Pode-se construir com aclive de 1:4 uma rampa inicial no incio da seo
convergente;

g-)

Pode-se construir um degrau na sada ao fim da seo divergente (vide figura 2);

h-)

Pode-se fazer uma concordncia em planta, na parte da entrada atravs de raios


convenientes, por exemplo, para medidores menores do que 12 um raio de 0,41
m, para medidores de 12 a 36 um raio de 0,51 m e para medidores de 48 a 96
um raio de 0,61 m;

i-)

O medidor de nvel deve estar instalado de forma a medir o valor da altura da


lmina de gua a montante e da altura da lmina de gua a jusante.

6. OPERAO
Operando-se com escoamento livre, basta uma medida da altura da lmina de gua a
montante para se conhecer a vazo. Esta medida feita na seo convergente, crista,
localizada a uma distncia de 2/3 do comprimento da parede convergente.
Na operao no desejada, porm possvel, ou seja, condio de escoamento por
submerso, alm da medida na crista, ser preciso tambm uma medida da altura da
lmina de gua a jusante, num ponto prximo da seo final da garganta.
Para medidores de 6 a 96, a posio dessa segunda medida dever ficar a 2 a
montante da parte final da seo estrangulada.
As relaes Hb/Ha e que constitui a vazo de submerso na prtica no deve
ultrapassar 95%.

7. MANUTENO
A manuteno de um medidor Parshall bastante simples, pois sua forma construtiva
dificulta o acmulo de sedimentos. Por isso, o medidor Parshall comumente utilizado
em esgoto e gua com slidos em suspenso
Porm, faz-se necessria uma vistoria cuja frequncia estudada caso a caso,
dependendo da sua condio de operao.
Alm do aspecto limpeza, observar as condies da calha propriamente dita, pois
dependendo do material de construo (se concreto, alvenaria, madeira, metal ou fibra
de vidro) pode ter tempo de vida varivel.

_______________________________________________________________________
10

Calha Parshall

Incontrol

8. FRMULAS E TABELAS
A funo matemtica para a norma ASTM 1941:1975 que expressa a vazo em
funo da altura :
Q = K x Hn
Onde:

K uma constante que depende das dimenses da calha e ajuste da


unidade de engenharia;
n um valor que difere ligeiramente de 3/2 (vide a tabela abaixo para
valores de K e n para diversos padres).
Valores de n K [para vazo em m3/h]
W
[inch]

[mm]

1
2
3
6
9
12
18
24
36
48
60
72
84
96

25,4
50,8
76,2
152,4
228,6
304,8
457,2
609,6
914,4
1219,2
1524,0
1828,8
2133,6
2438,4

1,550
1,550
1,547
1,580
1,530
1,522
1,538
1,550
1,556
1,578
1,587
1,595
1,601
1,606

217,29
434,58
633,60
1371,60
1926,00
2484,00
3794,40
5133,60
7855,20
10566,00
13420,80
16254,00
19101,60
21963,60

Tabela 6

9. MEDIDOR DE NVEL
O medidor Parshall pode ser fornecido com escala graduada em vazo, nas unidades
de engenharia de sua escolha. As unidades mais comuns so: m3/h, l/min, l/s ou m3/h.
Atualmente, o medidor de nvel mais utilizado na Calha Parshall do tipo ultrassnico,
por sua preciso (0,25% FE) e por sua praticidade, pois, como o sensor no entra
em contato direto com o fluido, no h problemas de incrustaes. Alm disso,
tambm temos a vantagem de transmitir distncia, atravs sinal eltrico, os valores
de vazo (instantnea ou totalizada), seja por um sinal analgico 4-20 mA, seja por
uma comunicao serial RS485, protocolo ModBus.
O medidor de nvel ultrassnico possui um conversor com leitura direta ou vazo, na
unidade de engenharia desejvel, como tambm podendo totalizar o volume do lquido
que j passou pelo medidor Parshall.

_______________________________________________________________________
11

Calha Parshall

Incontrol

10. CERTIFICADO DE GARANTIA


Este equipamento, Medidor de Vazo tipo Calha Parshall,
Modelo: ______________________
N. de srie: ___________________
garantido contra defeitos de mo de obra e material pelo prazo de 365 dias da data
de entrega. Esta garantia ser invalidada quando, a critrio de julgamento da
Incontrol, o equipamento tiver sido submetido a abusos ou manuseios imprprios.
Quando o reparo, dentro da garantia, for necessrio, o usurio dever remeter o
equipamento fbrica ou reposto, ficando as despesas de seguro e frete por conta e
risco do usurio.
Data de Entrega: ____/_____/_____

Incontrol

_______________________________________________________________________