Parameter 1 Parameter 2 Parameter 3 Parameter 4 Parameter 5 Parameter 6 Parameter 7 Parameter 8 Parameter 9 Parameter 10 Parameter 11 Parameter 12 Parameter 13 Parameter 14 Parameter

15 Parameter 16 Parameter 17 Parameter 18 Parameter 19 Parameter 20 Parameter 21 Parameter 22 Parameter 23 Parameter 24 Parameter 25 Parameter 26 Parameter 27 Parameter 28 Parameter 29 Parameter 30 Parameter 31 Parameter 32 Parameter 33 Parameter 34 Parameter 35 Parameter 36 Parameter 37 Parameter 38 Parameter 39 Parameter 40 Parameter 41 Parameter 42 Parameter 43

System rated frequency Generator frequency set point Generator set point voltage System rated voltage Secondary rated voltage of the transformer U1 Primary rated voltage of the transformer U1 Secondary rated voltage of the transformer U2 Primary rated voltage of the transformer U2 Automatic no-load control Voltage measuring Frequency controller Insensitivity frequency controller Minimum turn-on time frequency controller Gain factor frequency controller Maximum pause between two governor outputs Differential frequency for the output of a kick pulse Activation time until a kick pulse is output Duration of the kick pulse Voltage controller Insensitivity voltage controller Minimum turn-on time voltage controller Gain factor voltage controller Maximum pause between two governor outputs Synchronous functions Max. admissible diff. frequency for synchroniz. (pos. slip) Max. admissible diff. frequency for synchroniz. (neg. slip) Maximum admissible differential voltage for synchronization Minimum admissible differential angle for synchronization Pulse time of the add-on relay for synchronization Switcher time element of the power circuit breaker Asynchronous switching Dead bus start function 1: U1=U2=0 Dead bus start function 2: U1=0, U2=Um Dead bus start function 3: U1=Un, U2=0 Min. monitoring time of the dead bus start conditions Max. adm. zero voltage diff. for switching to the dead bus busbar Mini. rated voltage diff. for switching to the dead bus busbar Max. rated voltage diff. for switching to the dead bus busbar Relay function connect 2 Synchronizing time monitoring Final value of the synchronizing time monitoring Auto-acknowledgement of annunciations Ramp-down delay "annunciations"

48.0 to 62.0 Hz 48.0 to 62.0 Hz 30 to 120V 31 to 120V 32 to 120V 0,1 to 650.0 kV 32 to 120V 0,1 to 650.0 kV ON/OFF 1 phase L-N / 1 phase L-L / 3 phase ON/OFF 0.02 to 1.00 Hz 10 to 250 ms 0.1 to 99.9 0.0 to 52.0 s 0.01 to 0.10 Hz 1 to 99 s 10 to 250 ms ON/OFF 0.1 to 15.0/0.5 to 60.0 V 20 to 250 ms 0.1 to 99 0.0 to 52.0 s ON/OFF 0.02 to 0.49 Hz 0.00 to -0.49 Hz 0.5 to 10.0 % 0 to 99 50 to 1,000 ms 40 to 500 ms ON/OFF ON/OFF ON/OFF ON/OFF 0 to 20 s 3 to 50 % 1 to 20 % 0.05 to 5.00 Hz OFF /asynch.only/ synchr. only/ syn/asyn. ON/OFF 10 to 999 s ON/OFF 1 to 99 s

OFF 1 phase L-N