EPC 60 Retrofit

www.alfalaval.com

EPC 60 Retrofit

Automation development
EPC60

IPC 231 EPC41 EPC400 EPC30

MACE

EPC50

1965

1974

1979

1985

1999

2008

www.alfalaval.com

EPC 60 Retrofit

Reason to upgrade

MACE, IPC 231 and EPC 30: Not possible to get parts anymore EPC 41/400: The electrical components on the EPC print card is difficult to get hold of. In many cases we must special order parts.

www.alfalaval.com

EPC 60 Retrofit

Reason to upgrade

EPC 60 is using the latest technology Easy and logical human interface Supporting remote monitoring with Modbus TPC Easy fault finding and replacement with separate I/Os Built in P&I temperature controller Possible to utilize future upgrades

www.alfalaval.com

EPC 60 Retrofit

Replacing opportunities
Capable of replacing:
IPC 231 EPC 30 EPC 41 EPC 400

Compatible with:
MAPX MOPX WHPX MMPX LOPX FOPX MFPX
www.alfalaval.com

EPC 60 Retrofit

Automation development
EPC 400/41 Control cabinet Starter Air block

Power cabinet

EHS Heater Water block


16 15

Temperature sensor PT 100

Vibration switch

PS 41

PS 42
0 1 2 3 4

6
bar

4 0 ,6 0 ,4 2 0 ,2 0 0
bar MPa

8 0 ,8 1 1 ,2 1 2 1 0

Water transducer

2 3 4 56

1 0

8
0 1

www.alfalaval.com

EPC 60 Retrofit

Automation development
Water block kit Transformer kit Control cabinet kit
Air block Transformer kit

Air block kit

EPC 60 Control cabinet kit

Starter

Heater control box

16

We need to protect the new EPC We need to protect the new EPC 60 against cut-off voltage peaks 60 against cut-off voltage peaks To cover the customers need We have two different cabinets generated in the coils on the generated in the coils on the regarding supply voltage to the available; one for conventional water block. We mount these water block. We mount these system we have two different separators: WHPX, MOPX, MMPX protectors on the exiting coils. protectors on the exiting coils. transformer kits available. This isone for ALCAP; FOPX, LOPX and Water block for the EPC operation and valve/ and MFPX. The cabinets are the SRV operation. same but the program is Temperature sensor Transducer kit PT 100 different.
15

cabinet Temperature sensor kit EHS Heater

Power

Heater control box


The new EPC 60 needs two temperature signals and we supply a new 2xPT 100 sensor if not available in the old installation. The EPC 60 Retrofit is connected to the heater in another way than the old system so we need a heater control box to redirect the signals to and from the heater cabinet.

Vibration switch replacing coil

Pressure sensor kit

Since the EPC 60 uses 4-20mA signals to communicate with the We MT board we need to change to need to change the old pressure switches into a pressure the new MT 60 board. sensor working on a 4-20mA MT 60 signal to be able to communicate with the EPC 60.
2 3 4 56 1 0 8
1 0

Pressure transmitter kit


6 4 0,6 0,4 2 0,2 0 0
bar MPa

8 0,8 1 1,2 12 10

www.alfalaval.com

EPC 60 Retrofit

Selection process

Alfa Laval

Slide 10

www.alfalaval.com

EPC 60 Retrofit

Preparation process

Done by the crew or Alfa Laval service engineer Check that all the parts has arrived Prepare the installation Install new cables if necessary Mount new cabinets (Heater, transformer) Wright down all parameters from the old cabinet
Alfa Laval Slide 11

www.alfalaval.com

EPC 60 Retrofit

Installation

Done by the crew or Alfa Laval service engineer Install tall the new parts Mount new cabinets (Heater, transformer) Install new cables if necessary Connect all the cables

Alfa Laval

Slide 12

www.alfalaval.com

EPC 60 Retrofit

Commissioning

Done by Alfa Laval Service engineer Control of the installation Programming of the new EPC 60 Function test Start up

Alfa Laval

Slide 13

www.alfalaval.com

www.alfalaval.com