Metodo hardy cross

1ra Iteraccion
Circuito
I

Tuberia
A-B
B-C
A-C

D (pulg)

L (km)
6
6
8

C
0.7
0.6
0.5

100
100
100

AQ =

Circuito
II

Tuberia
B-C
B-D
C-D

D (pulg)

K
-130
-40
170

0.03928
0.03367
0.00692

36.94035 =

L (km)
6
7
7

C
0.6
0.8
0.8

Q
100
100
100

AQ =

37

K
40
-90
210

0.03367
0.02120
0.02120

-52.39987 =

-52

2da Iteraccion
Circuito
I

Tuberia
A-B
B-C
A-C

D (pulg)

L (km)
6
6
8

C
0.7
0.6
0.5

100
100
100

AQ =

Circuito
II

Tuberia
B-C
B-D
C-D

D (pulg)

K
-93.00000
49.00000
207.00000

0.03928
0.03367
0.00692

-0.98112 =

L (km)
6
7
7

C
0.6
0.8
0.8

Q
100
100
100

AQ =

-1

K
-49.00000
-142.00000
158.00000

0.03367
0.02120
0.02120

0.09582 =

3ra Iteraccion
Circuito
I

Tuberia
A-B
B-C
A-C

D (pulg)

L (km)
6
6
8

C
0.7
0.6
0.5

AQ =

Circuito

Tuberia

D (pulg)

L (km)

Q
100
100
100

K
-94.00000
48.00000
206.00000

0.03928
0.03367
0.00692

0.01864 =

II

B-C
B-D
C-D

6
7
7

0.6
0.8
0.8

100
100
100

AQ =

-48.00000
-142.00000
158.00000

0.03367
0.02120
0.02120

-0.13748 =

4ta Iteraccion
Circuito
I

Tuberia
A-B
B-C
A-C

D (pulg)

L (km)
6
6
8

C
0.7
0.6
0.5

100
100
100

AQ =

Circuito
II

Tuberia
B-C
B-D
C-D

D (pulg)

C
0.6
0.8
0.8

Tuberia
A-B
B-C
A-C

D (pulg)

Circuito
II

Tuberia
B-C
B-D
C-D

D (pulg)

C
0.7
0.6
0.5

L (km)
6
7
7

0.03928
0.03367
0.00692

K
-48.00000
-142.00000
158.00000

0.03367
0.02120
0.02120

-0.13748 =

L (km)
6
6
8

-94.00000
48.00000
206.00000

100
100
100

AQ =

Circuito
I

0.01864 =

L (km)
6
7
7

Q
100
100
100

C
0.6
0.8
0.8

K
-130
-40
170

Q
100
100
100

0.03928
0.03367
0.00692
K

40
90
210

0.03367
0.02120
0.02120

Hfo
-319.84363
-30.97467
92.55355
-258.26475

Hfo/Qo
Nuevo
2.46034
-93.00000
0.77437
49.00000
0.54443
207.00000
3.77914

30.97467
-87.44199
419.25386
362.78654

Hfo/Qo
Nuevo
0.77437
-49.00000
0.97158 -142.00000
1.99645
158.00000
3.74239

-172.12183
45.08774
133.23174
6.19765

Hfo/Qo
Nuevo
1.85077
-94.00000
0.92016
48.00000
0.64363
206.00000
3.41456

-45.08774
-203.28475
247.67774
-0.69475

Hfo/Qo
Nuevo
0.92016
-48.00000
1.43158 -142.00000
1.56758
158.00000
3.91932

-175.56140
43.40023
132.04347
-0.11770

Hfo/Qo
Nuevo
1.86767
-94.00000
0.90417
48.00000
0.64099
206.00000
3.41283

Hfo

Hfo

Hfo

Hfo

Hfo

Hfo/Qo

Nuevo

-43.40023
-203.28475
247.67774
0.99276

Hfo

0.90417
1.43158
1.56758
3.90333

-48.00000
-142.00000
158.00000

-175.56140
43.40023
132.04347
-0.11770

Hfo/Qo
Nuevo
1.86767
-94.00000
0.90417
48.00000
0.64099
206.00000
3.41283

-43.40023
-203.28475
247.67774
0.99276

Hfo/Qo
Nuevo
0.90417
-48.00000
1.43158 -142.00000
1.56758
158.00000
3.90333

Hfo

Hfo

Hfo/Qo
Nuevo
-319.86497
2.46050
-30.97805
0.77445
92.56282
0.54449

Hfo

Hfo/Qo
Nuevo
30.97805
0.77445
87.43484
0.97150
419.21958
1.99628