Você está na página 1de 1

GENERAL DATA

ITEM:
CAPACITY NOMINAL GEOMETRIC WORKING

DESIGN DATA
DESIGN CODE ASME VIII DIV.2
Item Description Ref. dwgs

NOZZLES LIST (Dimensions in mm)


Size Quantity Orientation ( a ) Distance to vertical axis (A) Distance to equator (B) Upper/Bottom cap

(Note 1) (m )
DIMENSIONS (SEE FIGURE)
3

EDITION WIND
INTERNAL DIAM. (I.D) HEIGHT (H)

SNOW

WORKING

SEISMIC ZONE

CALCULATION LOADS (kg/m2) CORROSION ALLOWANCE (mm) RADIOGRAPHY

(m) CLASSIFICATION AS PER APPLICABLE CODE (Note 2)

CONSTRUCTION DATA
(TO BE COMPLETED WITH VENDOR DATA) ZONE (SEE FIGURE) MATERIAL ZONE HEIGHT (m) NUMBER OF PLATES THICKNESS (mm)

PRODUCT NAME

PRODUCT DENSITY (kg/m3)


( AT OPER. TEMP.)

VAP. PRES (kg/cm2)


( AT OPER. TEMP.)

UPPER CAP UPPER INTERMEDIATE ZONE EQUATORIAL ZONE

OPERATION

DESIGN

LOWER INTERMEDIATE ZONE


TEMPERATURE

(C) MIN. MEAN AMBIENT MIN. DESIGN METAL

BOTTOM CAP NUMBER OF LEGS SUPPORTS

LEGS CIRCLE DIAMETER (m)

NOTES
1.- Geometric capacity: capacity resulting from the calculated geometric volume as per actual built dimensions. Nominal capacity: rounded value of geometric capacity Working capacity: practical capacity resulting from equipment filling or emptying operations 2.- The corresponding product group as per applicable legislation shall be indicated. For example, Class A, Subgroup A1, A2 as per "Reglamento de Instalaciones Petrolferas" and Group 1, flammable, toxic, etc. as per "Directiva de Equipos a Presin" in Spain 3.- Equipment category shall be indicated as per the applicable legislation. For example, "Directiva de Equipos a Presin" in Spain. 4.- The outer stairway shall be indicated in the List of Accessories, specifying the height at which the helical stairway starts and the platform width, as a minimum.

INTERNAL PRESSURE (kg/cm2g)

OPERATION

DESIGN

DIAMETER (mm) LEG-SPHERE CONNECTION

THICKNESS (mm)

MATERIAL

EXTERNAL PRESSURE (kg/cm2g)

OPERATION

DESIGN

LEGS

SURFACE TREATMENT
PAINT
PAINT SYSTEM PER PED-B0600.01 INTERNAL EXTERNAL FIRE PROOFED INSULATION

TYPE

THICKNESS (mm)

EXTENSION

HYDRO TEST PRESSURE (kg/cm g) SPHERE EQUIPMENT CLASSIFICATION AS PER APPLICABLE CODE (Note 3)
MAX MIN

SPHERE INSULATION LEGS INSULATION YES NO SPHERE FIRE PROOFING LEGS FIRE PROOFING (Note 4) REF. DWG. QTY.

FIGURES

LEGS

LEVEL
(m)

TOTAL HEAT TREATMENT

LIST OF ACCESSORIES
INLET OUTLET

MAXIMUM FLOW
(m /h)
3

ITEM

ACCESSORY

D.I

H
HYDRO TEST OPERATION

WEIGHT (kg)
EMPTY
WITH INTERNALS

EMPTY
WITHOUT REMOVABLE INTERNALS

PREPARED

DRAWING FILE

ANNEX NAME / DRAWING TITLE

CLIENT / PLANT

APPROVED

CONTRACTOR

STORAGE SPHERES DATA SHEET


ANNEX SPEC. DRAWING N SHEET

PROJECT REV. DESCRIPTION DATE PREP. APPR. CLIENT AUTH.

1 de 1
ELECTRONIC DRAWING (DO NOT REVIEW MANUALLY)

File N:

HD-D-0200.01-I-01.xls

Rev.:

01

Date:

MAR-05

Prep.:

C.A.B.

Revis.: M.G.D.

Appr.:

A.O.R N

HD-D-0200.01-I