Connect via LMP on ESMx using Ethernet cable Setup the local IP address on PC under Internet Protocol (TCP/IP) properties as follow: IP address: 192.168.255.130 Subnet Mask: 255.255.255.128 Default Gateway: none Personal Firewall may need to allow access to local network e.g. Zone Alarm The default settings of the BTS are: IP address: 192.168.255.131 2G Flexi BTS Site Manager connection TCP Port: 27500 2G Flexi BTS Site Manager SW download via TCP Port: 27501

Local Commissioning
Flexi 2G BTS Site Manager (2/2)

IP address of System Module, and Password just keep empty

Local Commissioning
Commissioning Wizard

Select the Commissioning Wizard menu item or click the Commissioning button on the View Selection Bar.

Local Commissioning
Undo Commissioning (1/4)
to revert the site to uncommissioned mode and he can also check the option that whether user wants to erase bypass capacity along with it or no. This button is disabled in remote connection

Local Commissioning
Undo Commissioning (2/4)

Local Commissioning
Undo Commissioning (3/4)

Indicate the BTS has successfully uncommissioned

Local Commissioning
Commissioning Manually

In this example, user do commissioning manually

Local Commissioning
Site Specific Information

Navigation tree - Enables user to navigate any screen, and update/view parameters corresponding to that screen. Data persistence is maintained across screen navigations

Local Commissioning
Hardware Configuration
If user has hardware template file (.epb or SCF file), specify from file can be selected In this example specify manually is selected]

Local Commissioning
Hardware Configuration Module Configuration
configure various radio modules, synchronization master, and radio masters

Local Commissioning
Hardware Configuration Local Sector setting
configure and associate antennas of only one type of RF unit (RM) to a particular local sector and specify per TRX power

Local Commissioning
Hardware Configuration Antenna Settings
Select the antenna line settings, specify MHA settings, provide information for feeder voltage, feeder loss, VSWR minor and major limits for the selected antenna

Local Commissioning
Hardware Configuration RFM EAC settings

configure the external alarm lines associated with the individual FRMs

Local Commissioning
Transmission Parameter

Enable satellite

Local Commissioning
Transmission Parameter Synchronization (Source)

Local Commissioning
Transmission Parameter LIF Setting

Local Commissioning
Transmission Parameter Abis Termination

Local Commissioning
Transmission Parameter Abis Allocation

Local Commissioning
Cross Connection Q1 Management

Local Commissioning
SCF preview - Summary
From this summary, user can check whether the commissioing step has been completed. This can be checked by looking at the indication color of each step, green means ok, red means not complete

Local Commissioning
Commissioning completeted

Local Commissioning
Tracing the traffic during the test call
From the toolbar select Test menu select Traffic trace select cell would be traced --> click Automatic Update (if necessary) For the CS call, yellow color indicates the RTSL that being occupied

Sanjaya kumar Idea cellular Ltd. Mo.98370897