Você está na página 1de 3

A

B
C
D
E
F
A
B
C
D
E
F
+K00
=K00
Siemens AG
2 3 4 1 5 6 7 8
2 3 4 1 5 6 7 8
Issue Revision Date Name
Date
Created by
Checked by
Standard
C
o
p
y
r
i g
h
t

(
C
)

S
I
E
M
E
N
S

A
G


1
9
9
7


A
l l
R
i g
h
t
s

R
e
s
e
r
v
e
d
Orig. / Repl. f. / Repl. by
AB Lesto
05.09.2012
Prieskienis
MT Zirniu g.,Vilnius
8DJH
8DJH
8DJH-61754
2012-09-04
System/rated frequency
3~50 Hz
Operating voltage
10.0 kV
Rated voltage
12.0 kV
Rated short-time withst. curr.
16.0 kA (1 s)
Rated normal current
630 A
Single Line Diagram 1
Sh.No 01-
B01
=K01
+K01
=KZ04
=K02
+K02
=KZ02
=K03
+K03
=KZ01
=K04
+K04
=KZ02
=K05
+K05
=KZ04
-Q1
630 A
-A51
Aerouosto TP
S3-10
-Q1
630 A
-Q0
-A51
-T21
3
IKI-30 sensor
T-1
-Q1
630 A
SGS
-Q1
630 A
-Q0
-A51
-T21
3
IKI-30 sensor
T-2
-Q1
630 A
-A51
Aerouosto TP
S2-10
A
B
C
D
E
F
A
B
C
D
E
F
+K00
=K00
Siemens AG
2 3 4 1 5 6 7 8
2 3 4 1 5 6 7 8
1.8 kN
3.0 kN
4.0 kN
3.5 kN
6 kN/m
15 mm
50 mm
200 mm
2000 mm
2400 mm
1000 mm x 2000 mm
1000 mm x 2200 mm
1200 mm x 2500 mm
LOAD DATA AND MINIMUM DISTANCES
1.) MAX. PERMANENT LOADS
Fv VERTICAL SINGLE LOAD
PANEL WIDTH 310 mm
PANEL WIDTH 430 mm
PANEL WIDTH 500 mm
PANEL WIDTH 840 mm
2.) NON PERMANENT LOADS
pa MAX LIVE LOAD
3.) MINIMUM DISTANCES
WALL CLEARANCE REAR
WALL CLEARANCE LEFT / RIGHT
WITH EXTENSION
4.) HEIGHT OF CEILING
SWITCHGEAR HEIGHT 1400 mm *
SWITCHGEAR HEIGHT 2000 mm / 2300 mm
5.) MINIMUM DOOR OPENING
SWITCHGEAR HEIGHT 1700 mm *
SWITCHGEAR HEIGHT 2000 mm
SWITCHGEAR HEIGHT 2300 mm
* WITHOUT CABLE DUCT OR LV-CABINET
Issue Revision Date Name
Date
Created by
Checked by
Standard
C
o
p
y
r
i g
h
t

(
C
)

S
I
E
M
E
N
S

A
G


1
9
9
7


A
l l
R
i g
h
t
s

R
e
s
e
r
v
e
d
Orig. / Repl. f. / Repl. by
AB Lesto
05.09.2012
Prieskienis
MT Zirniu g.,Vilnius
8DJH
8DJH
8DJH-61754
2012-09-04
System/rated frequency
3~50 Hz
Operating voltage
10.0 kV
Rated voltage
12.0 kV
Rated short-time withst. curr.
16.0 kA (1 s)
Rated normal current
630 A
FRONT VIEW
Location diagram
THE LOCATION AND DETAIL DIAGRAMS
DO HAVE SYMBOLIC CHARACTER AND
DO NOT SHOW THE ACTUAL SCOPE OF
SUPPLY.
1
Sh.No 01-
B01
=K01
+K01
=KZ04
=K02
+K02
=KZ02
=K03
+K03
=KZ01
=K04
+K04
=KZ02
=K05
+K05
=KZ04
310mm 310mm 430mm 430mm 430mm
1910mm
T*1 T*2
2
0
0
m
m
1
4
0
0
m
m
6
0
m
m
1
6
0
0
m
m
A
B
C
D
E
F
A
B
C
D
E
F
+K00
=K00
Siemens AG
2 3 4 1 5 6 7 8
2 3 4 1 5 6 7 8
1.8 kN
3.0 kN
4.0 kN
3.5 kN
6 kN/m
15 mm
50 mm
200 mm
2000 mm
2400 mm
1000 mm x 2000 mm
1000 mm x 2200 mm
1200 mm x 2500 mm
LOAD DATA AND MINIMUM DISTANCES
1.) MAX. PERMANENT LOADS
Fv VERTICAL SINGLE LOAD
PANEL WIDTH 310 mm
PANEL WIDTH 430 mm
PANEL WIDTH 500 mm
PANEL WIDTH 840 mm
2.) NON PERMANENT LOADS
pa MAX LIVE LOAD
3.) MINIMUM DISTANCES
WALL CLEARANCE REAR
WALL CLEARANCE LEFT / RIGHT
WITH EXTENSION
4.) HEIGHT OF CEILING
SWITCHGEAR HEIGHT 1400 mm *
SWITCHGEAR HEIGHT 2000 mm / 2300 mm
5.) MINIMUM DOOR OPENING
SWITCHGEAR HEIGHT 1700 mm *
SWITCHGEAR HEIGHT 2000 mm
SWITCHGEAR HEIGHT 2300 mm
* WITHOUT CABLE DUCT OR LV-CABINET
Issue Revision Date Name
Date
Created by
Checked by
Standard
C
o
p
y
r
i g
h
t

(
C
)

S
I
E
M
E
N
S

A
G


1
9
9
7


A
l l
R
i g
h
t
s

R
e
s
e
r
v
e
d
Orig. / Repl. f. / Repl. by
AB Lesto
05.09.2012
Prieskienis
MT Zirniu g.,Vilnius
8DJH
8DJH
8DJH-61754
2012-09-04
System/rated frequency
3~50 Hz
Operating voltage
10.0 kV
Rated voltage
12.0 kV
Rated short-time withst. curr.
16.0 kA (1 s)
Rated normal current
630 A
PLAN VIEW
Constructional Data
THESE CONSTRUCTIONAL DATA OF
SIEMENS AG ARE NOT BINDING FOR
CONSTRUCTION. THEY ARE ONLY VALID
AS A BASE FOR PRODUCTION OF
BINDING CONSTRUCTIONAL DRAWINGS.
FURTHER INFORMATION ACCORDING
CONSTRUCTIONAL DATA CAN BE
FOUND IN THE RELATED OPERATING
AND INSTRUCTION MANUAL.
1
Sh.No 01-
B01
WxD
230x610
WxD
390x610
WxD
350x610
WxD
350x610
WxD
270x610
=K01
+K01
=KZ04
=K02
+K02
=KZ02
=K03
+K03
=KZ01
=K04
+K04
=KZ02
=K05
+K05
=KZ04
310mm 310mm 430mm 430mm 430mm
1910mm
T*1 T*2
7
7
5
m
m
7
1
4
m
m

Você também pode gostar