Date :SHEAR STRENGTH OF DIA.

400

28-Oct-14

mm CLASS C8STD

ICP PRETENSIONED SPUN HIGH STRENGTH CONCRETE PILES (JIS A5337:1985)

2tI
So

2
( fp + 2 fc ) - fp
2

(JIS A5337: 1985: Clause 9.3.2)

Where :
Q = Shearing strength
t

= Thickness of pile

80

mm

I = Moment of inertia

(r04 - r4)

= 1.09E+09 mm4

r0 = Outside radius of pile

200

mm

r = Inside radius of pile

120

mm

So = Statical moment of area of section above gravity centre axis


2

(r03 - r3)

(JIS A5337: 1985: Clause 9.3.2)

= 4.18E+06 mm3

fp = Effective prestress

8.1

N/mm2

fc = Tensile strength of concrete

4.02

N/mm2

= Factor

0.5

Therefore:
Q

2 x

80

x 1.09E+09

4.18E+06

188672

19.2

Tons

1
2

x { [ 8.1 + ( 2 x 0.5 x

4.02

) ] 2 - 8.1