Você está na página 1de 20

Vacuum generators OVEM

Vacuum generators OVEM


Key features
At a glance
Accelerated vacuum reduction for safe
placement of the workpiece by means of
integrated solenoid valve for controlling
the ejector pulse

Quick and secure installation


thanks to QS fitting
Fast vacuum build-up by means of
integrated solenoid valve for controlling
the compressed air supply

Central electrical connection via M12 plug


OVEM--2P/2N/PU/NU/PI/NI
Monitoring and visualisation of the
vacuum by means of a vacuum sensor
with LCD display (bar)

OVEM--1P/1N
Monitoring of the vacuum and status
displays for switching output and solenoid
valves by means of a vacuum sensor with
LED display

Adjustment of the ejector pulse via flow


control screw

Prevention of pressure drops by means of


integrated non-return valve

Prevention of contamination of the


vacuum generator by means of integrated
filter

Maintenance-free operation and reduced


noise level through integrated, open
silencer

The modular vacuum generator series


The modular vacuum generator series
OVEM offers a wide range of
individually selectable functions,
making it possible to find a solution
for the most varied of applications.

Functions

Values

Laval nozzle

0.45 mm
0.7 mm
0.95 mm
1.4 mm
2.0 mm1)
High vacuum
High suction rate
20 mm, metric version, display in bar
20 mm, NPT version, display in inchHg2)
QS fittings, with or without open silencer
QS fittings (inch), with or without open silencer2)
G female thread, with or without open silencer
NPT female thread, with or without open silencer2)
Prepared for supply manifold
Normally open, with or without ejector pulse
Normally closed, with or without ejector pulse
M12 plug (5-pin)
Without vacuum sensor
Switching output 1x PNP or 1x NPN3)
Switching output 2x PNP or 2x NPN4)
Switching output 1x PNP or 1x NPN and analogue output4)
inchHg4)
inchH2O2) 4)
bar2) 4)

Vacuum generator characteristic


Housing size
Pneumatic connections

Normal position of the vacuum


generator
Electrical connection
Vacuum sensor

Alternative vacuum display

1)
2)
3)
4)

Restricted number of functions


Product documentation Internet: ovem-npt
Vacuum sensor with LED display
Vacuum sensor with LCD display

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Key features
The innovative vacuum generator
Economical
 Short switching times thanks to
integrated solenoid valves
Vacuum on/off
Ejector pulse
 Quick, precise and safe placement
of the workpiece by means of the
ejector pulse
 Cost saving through preventive
maintenance/service thanks to
maintenance indicator
Reliable
 Permanent monitoring of the entire
vacuum system via a vacuum
sensor to reduce downtimes
(condition monitoring)
 Prevention of pressure drop by
means of an integrated air-saving
function in conjunction with an
integrated non-return valve

Easy to use
 Cost saving through integrated
air-saving function
 Powerful supply of multiple vacuum
generators via a common supply
manifold ( page 18)
 Low-cost variants with one
switching output (OVEM--1P/1N)

Space-saving
All functions are compactly integrated
in one unit
 No protruding elements such as
valves or vacuum sensor
 Space-optimised installation is
possible as all the control elements
can be accessed from one side

Operating principle of OVEM


Vacuum ON/OFF
The compressed air supply is
controlled by an integrated solenoid
valve. The solenoid valve can be
supplied with two different switching
functions, NC and NO.
 NC - normally closed:
The vacuum is generated when the
vacuum generator is pressurised
with compressed air and the
solenoid valve has been switched.

 Simple installation via M12 plugs


and QS fittings
 Simple mounting via screws
 All control elements on one side
 Quiet operation thanks to
integrated silencers

Easy to maintain
 Integrated filter with inspection
window for maintenance display
 Reduced contamination of the
vacuum generator thanks to an
open silencer

Vacuum sensor
 NO - normally open:
The vacuum is generated when the
vacuum generator is pressurised
with compressed air and the
solenoid valve is in the normal
position.

The set or taught-in reference value for


the generated vacuum is monitored
via an integrated vacuum sensor. If the
reference value is reached or if it is not
reached due to malfunctions
(e.g. leakages, dropped workpiece),
the vacuum sensor emits an electrical
signal.

OVEM--1P/1N
 Switching inputs for actuating the
solenoid valves for vacuum
generation and ejector pulse
 One switching output for supplying
a control signal
Configured as an N/O contact
Switching function configured as
a threshold value comparator

OVEM--2P/2N/PU/NU/PI/NI
 One digital switching input for
actuating the solenoid valves
 Two digital switching outputs or
one digital switching output and
one analogue output for supplying
control signals
Switching outputs can be
configured as N/C or N/O contacts
Switching function of the outputs
can be configured as a threshold
value or window comparator

 Vacuum sensor with LCD display


(OVEM--2P/2N/PU/NU/PI/N)
Vacuum is displayed numerically
and as a bar chart
Important parameters and
diagnostic information are
displayed

Choice of mounting types


 Direct mounting or via mounting
bracket
 Straightforward mounting on H-rail
via accessories
 Interlocking of multiple vacuum
generators on a common supply
manifold ( page 18)

Ejector pulse
With a second integrated solenoid
valve, an ejector pulse is activated
and generated after the vacuum is
switched off to release the workpiece
safely from the suction cup and to
reduce the vacuum quickly.

Connection to higher-level systems


The connection to higher-level systems
as well as the configuration of the
switching outputs depends on the type
of vacuum sensor.

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

 If there are two switching outputs,


these can be configured
independently of each other. This
enables tasks to be performed in
parallel with one vacuum generator,
reducing the time needed for
sorting good and reject parts, for
example.

Vacuum generators OVEM


Key features
OVEM--2P/2N/PU/NU/PI/NI Air-saving function LS (-CE, -OE)
50 mbar (fixed)

Hysteresis
1
2

If the desired threshold value 1 for


the vacuum is reached, vacuum
generation is automatically switched
off. A non-return valve prevents the
reduction of the vacuum.
Nonetheless, leakage (e.g. due
to rough workpiece surfaces) will

slowly reduce the vacuum. If the


pressure drops below the threshold
value 2, vacuum generation is
automatically switched on. Vacuum is
generated until the set threshold
value 1 is reached again.

The main operating parameters


 vacuum
 evacuation time and
 air supply time
are continuously measured in the
vacuum generator and compared with
the individually set reference values
(condition monitoring). If deviations in
the reference values occur, these will
be determined by the vacuum

generator and shown on the display


(diagnostics). An electrical signal will
also be transmitted to the higher-order
controller.
This permits preventative action
 in order to prevent machine failure
or downtime, for example, through
timely maintenance
 and to ensure process reliability
(adherence to the cycle time).

The switching point is determined


from the teach-in point and the
functional reserve.
A functional reserve (35% of the
teach-in pressure) is subtracted from
the teach-in pressure
(SP = TP 0.35*TP).

For example, a switching point of


0.33 bar is set at a teach-in pressure
of 0.5 bar.
The hysteresis is fixed.

OVEM--2P/2N/PU/NU/PI/NI Condition monitoring and diagnostics


1
2

TE
1 Cycle time
2 Monitoring
TE Evacuation time

T1

TB

T2

T1 Transport time
TB Air supply time
T2 Return time

OVEM--1P/1N From the teach-in point to the switching point

TP Teach-in point
SP Switching point

Hy Hysteresis
FR Functional reserve

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Peripherals overview
OVEM--PL/PO-1)

OVEM--QS/QO/GN/GO-

8
9

aJ
3
8
5

1)

Hollow bolt 9 and mounting bracket aJ are included in the scope of delivery of the OVEM--PL/PO-.

Mounting attachments and accessories


OVEM--QS/QO/GN/GO-
QS
QO
GN
1
2
3
4
5
6
7
8

2)

Connecting cable
NEBU-M12
H-rail mounting kit
OABM-H
Mounting bracket
HRM-1
Blanking plug
OASC-G1-P
Common supply manifold
OABM-P
Silencer extension
UOMS-
Suction gripper
ESG
Push-in fitting
QS
Suction cup holder
ESH
Suction cup
ESS

Page/Internet

OVEM--PL/PO-
PL

PO

n2)

GO

n2)

19
20
19
18
n2)

20

20
esg
quick star

esh

ess

Silencer extension UOMS- 6 is included in the scope of delivery of the OVEM-20.

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

Vacuum generators OVEM


Type codes

OVEM

10

QO CE

2P

Type
OVEM

Vacuum generator

Nominal size of laval nozzle [mm]


05
07
10
14
20

0.45
0.7
0.95
1.4
2.0

Ejector characteristic
H
L

High vacuum
High suction rate

Housing width
B

Grid dimension 20 mm

Pneumatic connections
QS
QO
GN
GO
PL
PO

P-V-R with QS fitting


P-V with QS fitting,
R with open silencer
P-V-R with female thread
P-V with female thread,
R with open silencer
Prepared for common supply manifold,
V-R with QS fitting
Prepared for common supply manifold, V with QS fitting, R with
open silencer

Normal position of the vacuum generator


ON
OE
CN
CE

NO, normally open (vacuum generation)


NO, normally open (vacuum generation) with ejector pulse
NC, normally closed (no vacuum generation)
NC, normally closed (no vacuum generation) with ejector pulse

Electrical connection
N

Plug M12 (5-pin)

Vacuum sensor

1P
1N
2P
2N
PU
PI
NU
NI

Without vacuum sensor


1 switching output PNP
1 switching output NPN
2 switching outputs PNP
2 switching outputs NPN
1 switching output PNP, 1 analogue output 0 10 V
1 switching output PNP, 1 analogue output 4 20 mA
1 switching output NPN, 1 analogue output 0 10 V
1 switching output NPN, 1 analogue output 4 20 mA

Vacuum display

bar
inchHg

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Technical data
Function
NC, normally closed:
 Ejector pulse
 QS fitting or G female thread
 With open silencer
 Prepared for common supply
manifold

-Q-L-

Temperature range
0 +50 C

Operating pressure
2 8 bar

NO, normally open:


 Ejector pulse
 QS fitting or G female thread
 With open silencer
 Prepared for common supply
manifold

OVEM--2P/2N/PU/NU/PI/NI

General technical data


Type
Nominal size of laval nozzle
Grid dimension
Grade of filtration
Mounting position
Type of mounting

OVEM-05
[mm]
[mm]
[m]

OVEM-07

Pneumatic connection 1 (P)


Vacuum port (V)
Pneumatic connection 3 (R)

0.45
0.7
20
40
Any
Via through-hole
Via female thread
Via accessories
Dimensions on page 12
Dimensions on page 12
Dimensions on page 12

Technical data Design


Type

OVEM-05/07/10/14/20--QO/PO/GO

Design
Ejector characteristic
Silencer design
Integrated function

ON/CN

OE/CE

Valve function
Manual override

1)
2)

ON/OE
CN/CE

Modular
High vacuum/standard H
High suction rate/standard L
Open
On-off valve, electrical
Vacuum sensor1)
Filter
Silencer, open
On-off valve, electrical
Ejector pulse, electrical
Flow control valve
Vacuum sensor1)
Air-saving function, electrical2)
Non-return valve
Filter
Silencer, open
Open
Closed
Non-detenting
Additionally via control buttons2)

OVEM--1P/1N

OVEM-10

OVEM-14

OVEM-20

0.95

1.4

2.0

OVEM-05/07/10/14/20--QS/GN/PL

On-off valve, electrical


Vacuum sensor1)
Filter

On-off valve, electrical


Ejector pulse, electrical
Flow control valve
Vacuum sensor1)
Air-saving function, electrical2)
Non-return valve
Filter

Only with OVEM--2P/2N/PU/NU/PI/NI/1P/1N


Only possible with OVEM--2P/2N/PU/NU/PI/NI

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

Vacuum generators OVEM


Technical data
Operating and environmental conditions
Type
Operating pressure
Nominal operating pressure
Operating medium
Note on operating/pilot medium
Ambient temperature
Temperature of medium
Relative air humidity
Degree of contamination
Corrosion resistance class CRC1)
CE mark (see declaration of conformity)
Certification

1)

2)

[bar]
[bar]

[C]
[C]
[%]

OVEM-05/07/10/14/20--QO/PO/GO

OVEM-05/07/10/14/20--QS/GN/PL

28
26
6
Compressed air in accordance with ISO 85731:2010 [7:4:4]
Operation with lubricated medium not possible
0 +50
0 +50
5 85
3
2
To EU EMC Directive2)
cULus - Listed (OL)
C-Tick

Corrosion resistance class CRC 2 to Festo standard FN 940070


Moderate corrosion stress. Indoor applications in which condensation may occur. External visible parts with primarily decorative requirements for the surface and which are in direct contact with the ambient atmo
sphere typical for industrial applications.
For information about the applicability of the component see the manufacturers EC declaration of conformity at: www.festo.com/sp User documentation.
If the component is subject to restrictions on usage in residential, office or commercial environments or small businesses, further measures to reduce the emitted interference may be necessary.

Performance data High vacuum


Type

OVEM-05

Normal position of the vacuum generator


Max. vacuum
[%]
Operating pressure for max. vacuum
[bar]

ON OE
93
5.1

Max. suction rate with respect to


atmosphere
Suction rate at p1 = 6 bar

[l/min]

OVEM-07
CN

CE

ON OE

OVEM-10
CN

CE

ON OE

OVEM-14
CN

CE

ON OE

OVEM-20
CN

CE

ON OE

4.1

3.5

3.6

5.3

16

19.5

50.5

86.5

[l/min]

5.9

15.1

18.6

46

80.5

Air supply time1) for 1 l volume,


at p1 = 6 bar

[s]

4.8 2

Noise level at p1 = 6 bar

[db(A)]

51

1)

1.9 0.4 1.9 0.4 1.2 0.2 1.2 0.2 0.6 0.2 0.6 0.2 0.4 0.2 0.4 0.2

58

OVEM-05

Normal position of the vacuum generator


Max. suction rate with respect to
[l/min]
atmosphere
Suction rate at p1 = 6 bar
[l/min]

ON
13

Air supply time1) for 1 l volume,


at p1 = 6 bar

[s]

Noise level at p1 = 6 bar

[db(A)]

45

CE

73

77

74

Time required to reduce vacuum to 0.05 bar.

Performance data High suction rate


Type

1)

4.8 2

CN

OE

OVEM-07
CN

CE

12.8

ON OE
31.5

OVEM-10
CN

CE

31.5
1.3

1.3

53

ON
45

OE

OVEM-14
CN

CE

45.1
0.2

0.2

0.8

64

ON
92

OE

CN

CE

0.2

0.4

0.2

88.7
0.2

0.8

0.2

0.4

70

Time required to reduce vacuum to 0.05 bar.

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Technical data
Technical data Vacuum sensor
Electrical switching output
Mechanical
Measured variable
Measuring principle
Pressure measuring range
Accuracy FS1)
Repetition accuracy
of switching value FS1)
Setting options
Threshold value setting range
Hysteresis setting range
Setting range for ejector pulse time
Display type
Displayable units
Display range

2P

[bar]
[%]
[%]

[bar]
[bar]
[ms]

H
[bar]
[inchHg]

Switching status display


Switching position display
Electrical connection
Electrical
Switching output
Switching input to standard
Switching element function
Switching function
Fixed hysteresis
Operating voltage range
Duty cycle
Coil characteristics 24 V DC

[mbar]
[V DC]
[%]
[W]

Max. current consumption


Max. output current
Idle current
Residual current
Insulation voltage
Surge capacity
Voltage drop
Inductive protective circuit
Analogue output

[mA]
[mA]
[mA]
[mA]
[V]
[kV]
[V]

Permitted load resistance


for analogue output
Accuracy of analogue output FS1)
Protection against short circuit
Protection against overloading
Reverse polarity protection
Protection class
Electrical protection class
1)
2)

[V]
[mA]
[ohms]
[%]

2N

PU

NU

PI

NI

Relative pressure
Piezoresistive
1 0
3
0.6

1P

1N

0.5
0.6

Via display and keys


0.999 0
0.9 0
20 9,999 (OVEM-05)
40 9,999 (OVEM-07/10/14/20)
4-character alphanumeric, backlit LCD
bar
inchHg
0.999 0
29.5 0
Visual
LCD
Plug M12x1, 5-pin

2x PNP
2x NPN
1x PNP
IEC 61131-2
N/O contact
N/C contact
Window comparator
Threshold value comparator2)

20.4 27.6
100
Low-current phase: 0.3
High-current phase: 2.55
270
180
100
70
0.1
50
0.8
1.5
Adapted to MZ, MY, ME coils

0 10

Min. 2,000

Teach-in
1 0

LED

Visual
LED

1x NPN

1x PNP

1x NPN

1x PNP

1x NPN

20

80

4 20
Max. 500

4
Yes
Yes
For all electrical connections
IP65
III

% FS = % of the measuring range final value (full scale)


OVEM--1P/1N threshold value with fixed hysteresis

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

Vacuum generators OVEM


Technical data
Pin allocation
Plug M12x1, 5-pin

Pin

Meaning
OVEM--2P/2N/PU/NU/PI/NI

1
2
3
4
5

1)

OVEM--1P/1N

Supply voltage +24 V DC


Output B (function depending on variant)
0V
Output A (switching output for vacuum sensor)
Switching input In
(vacuum ON/OFF and ejector pulse)

Supply voltage +24 V DC


Switching input for vacuum ON/OFF
0V
Switching output1)
Switching input for ejector pulse ON/OFF

Pin 4 not used in types without vacuum sensor

Materials
Sectional view
1 2

aJ

Type OVEM
1
2
3
4
5

Fitting
Connecting thread
Pin contacts
Plug housing
Inspection window
Housing

6
7
8
9

Key pad
Adjusting screw
Filter housing
Fitting

aJ

Connecting thread
Silencer
Fitting

Screws

Pins

Jet nozzle

Receiver nozzle

Filter

Seals

Hollow bolt

Mounting bracket
Note on materials

2P/2N/PU/NU/
PI/NI
QS/QO
GN/GO

CE/OE
QS/QO/
PL/PO
GN/GO
QO/GO/
PO
QS/QO/
PL/PO
GN/GO

PL/PO
PL/PO
QO/GO/
PO

1P/1N

Nickel-plated brass
Anodised wrought aluminium alloy
Gold-plated brass
Nickel-plated brass
PA

Die-cast aluminium,
PA-reinforced
TPE-U
PA-reinforced
Steel
PA-reinforced
Nickel-plated brass
Anodised wrought aluminium alloy
Wrought aluminium alloy,
PU foam
Nickel-plated brass
Anodised wrought aluminium alloy
Steel
Steel
Wrought aluminium alloy
POM
Fabric, PA, sintered steel
Nitrile rubber
Wrought aluminium alloy
Stainless steel
RoHS-compliant
Contains PWIS (paint-wetting
impairment substances)

10

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Technical data
Vacuum pu as a function of operating pressure p1
High vacuum

OVEM-05-H
OVEM-07-H
OVEM-10-H
OVEM-14-H
OVEM-20-H

High suction rate

OVEM-05-L
OVEM-07-L
OVEM-10-L
OVEM-14-L

Evacuation time t as a function of vacuum pu for 1 l volume at 6 bar operating pressure


High vacuum
High suction rate

OVEM-05-H
OVEM-07-H
OVEM-10-H
OVEM-14-H
OVEM-20-H

OVEM-05-L
OVEM-07-L
OVEM-10-L
OVEM-14-L

Air consumption qn as a function of operating pressure p1


High vacuum/high suction rate

OVEM-05
OVEM-07
OVEM-10
OVEM-14
OVEM-20

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

11

Vacuum generators OVEM


Technical data
Download CAD data www.festo.com

Dimensions
OVEM-05

1
2
3
4

Supply port (P)


Vacuum port (V)
Exhaust port (R)
Electrical connection to fit
NEBU-M12G5-K-
5 Mounting thread M3,
max. tightening torque 0.8 Nm
6 Mounting hole,
max. tightening torque 2.5 Nm
7 Mounting bracket (only with
OVEM--PL/PO)
Type
OVEM-05--QS-
OVEM-05--QO-
OVEM-05--PL-
OVEM-05--PO-
OVEM-05--GN-
OVEM-05--GO-
Type
OVEM-05--QS-
OVEM-05--QO-
OVEM-05--PL-
OVEM-05--PO-
OVEM-05--GN-
OVEM-05--GO-
1)
2)

12

Pneumatic connections
P
V
R
QS-6

QS-6

(G)1)

QS-6

Gx

Gx

H5

H6

QS-8
SD2)
QS-8
SD2)
Gx
SD2)
L1

D1

D2

D3

B1

B2

H1

H2

H3

H4

M12x1

M3

5.5

20.5

12.6

90

68

26

14.5

L5

L6

L7

L8

L9

L10

51

25

18

37

33

L2

L3
6.5

6.5
40

14.5

115

8.2

8.2

L4
12

12

8.2

160.5

Thread for mounting on the common supply manifold 18


SD = Silencer

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Technical data
Download CAD data www.festo.com

Dimensions
OVEM-07/10

1
2
3
4

Supply port (P)


Vacuum port (V)
Exhaust port (R)
Electrical connection to fit
NEBU-M12G5-K-
5 Mounting thread M3,
max. tightening torque 0.8 Nm
6 Mounting hole,
max. tightening torque 2.5 Nm
7 Mounting bracket (only with
OVEM--PL/PO)
Type
OVEM-07/10--QS-
OVEM-07/10--QO-
OVEM-07/10--PL-
OVEM-07/10--PO-
OVEM-07/10--GN-
OVEM-07/10--GO-
Type
OVEM-07/10--QS-
OVEM-07/10--QO-
OVEM-07/10--PL-
OVEM-07/10--PO-
OVEM-07/10--GN-
OVEM-07/10--GO-
1)
2)

Pneumatic connections
P
V
R
QS-8

QS-8

(G)1)

QS-8

H5

H6

QS-8
SD2)
QS-8
SD2)
Gy
SD2)
L1

D1

D2

D3

B1

B2

H1

H2

H3

H4

M12x1

M3

5.5

20.5

12.6

90

68

26

14.5

L5

L6

L7

L8

L9

L10

51

25

18

46.5

33

L2

L3
6.5

6.5
40

14.5

128

17.2

17.2

L4
12
17.3
12
17.3

17.3

160.5

Thread for mounting on the common supply manifold 18


SD = Silencer

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

13

Vacuum generators OVEM


Technical data
Download CAD data www.festo.com

Dimensions
OVEM-14/20

1
2
3
4
5
6
7
8

Type
OVEM-14/20--QS-
OVEM-14/20--QO-
OVEM-14/20--PL-
OVEM-14/20--PO-
OVEM-14/20--GN-
OVEM-14/20--GO-
Type
OVEM-14/20--QS-
OVEM-14/20--QO-
OVEM-14/20--PL-
OVEM-14/20--PO-
OVEM-14/20--GN-
OVEM-14/20--GO-
1)
2)

14

Pneumatic connections
P
V
R
QS-8

QS-8

(G)1)

QS-8

H5

H6

QS-8
SD2)
QS-8
SD2)
Gy
SD2)
L1

L2

D1

D2

D3

B1

B2

H1

H2

H3

H4

M12x1

M3

4.3

20.5

12.6

90

68

25

14.5

L3

L4

L5

6.5
6.5
40

14.5

158

17.2

Supply port (P)


Vacuum port (V)
Exhaust port (R)
Electrical connection to fit
NEBU-M12G5-K-
Mounting thread M3,
max. tightening torque 0.8 Nm
Mounting hole,
max. tightening torque 2.5 Nm
Mounting bracket (only with
OVEM--PL/PO)
Silencer extension (in the scope
of delivery of the OVEM-20)

17.2

12
17.3
12
17.3

17.3

L6

L7

L8

L9

L10

L11

L12

39

k230

k230

k230

160.5

57

25

18

46.5

33

Thread for mounting on the common supply manifold 18


SD = Silencer

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Technical data
Ordering data and weight
Circuit symbol

Description

Electrical
switching
output

Nominal
size of laval
nozzle
[mm]

Weight

0.45
0.7
0.95
1.4

317
322

0.45
0.7
0.95
1.4
2.0
0.7
0.95
1.4
0.45
0.7
0.95
1.4
2.0

325
330

0.7
0.95
1.4
0.7
0.95
1.4
0.45
0.7
0.95
1.4

335

2.0
2.0

415

Part No.

Type

538834
538835
538836
539998

OVEM-05-H-B-QO-CN-N-2P
OVEM-07-H-B-QO-CN-N-2P
OVEM-10-H-B-QO-CN-N-2P
OVEM-14-H-B-QO-CN-N-2P

538831
538832
538833
539997
8023700
540018
540019
540020
540021
540022
540023
540024
8023699

OVEM-05-H-B-QO-CE-N-2P
OVEM-07-H-B-QO-CE-N-2P
OVEM-10-H-B-QO-CE-N-2P
OVEM-14-H-B-QO-CE-N-2P
OVEM-20-H-B-QO-CE-N-2P
OVEM-07-H-B-QO-CE-N-2N
OVEM-10-H-B-QO-CE-N-2N
OVEM-14-H-B-QO-CE-N-2N
OVEM-05-H-B-QO-CE-N-1P
OVEM-07-H-B-QO-CE-N-1P
OVEM-10-H-B-QO-CE-N-1P
OVEM-14-H-B-QO-CE-N-1P
OVEM-20-H-B-QO-CE-N-1P

540015
540016
540017
540012
540013
540014
540025
540026
540027
540028

OVEM-07-H-B-GO-CE-N-2P
OVEM-10-H-B-GO-CE-N-2P
OVEM-14-H-B-GO-CE-N-2P
OVEM-07-H-B-GO-CE-N-2N
OVEM-10-H-B-GO-CE-N-2N
OVEM-14-H-B-GO-CE-N-2N
OVEM-05-H-B-GO-CE-N-1P
OVEM-07-H-B-GO-CE-N-1P
OVEM-10-H-B-GO-CE-N-1P
OVEM-14-H-B-GO-CE-N-1P

[g]

NC Normally closed
P-V with QS fitting,
R with open silencer

With ejector pulse,


P-V with QS fitting,
R with open silencer

2x PNP

2x PNP

2x NPN

PNP

With ejector pulse,


P-V with female thread,
R with open silencer

2x PNP

2x NPN

PNP

With ejector pulse,


prepared for common supply
manifold,
V with QS fitting,
R with open silencer

2014/10 Subject to change

2x PNP
PNP

370

380
390
330
380
313
321
371
390

385
335
385
302
325
375

8023702 OVEM-20-H-B-PO-CE-N-2P
8023701 OVEM-20-H-B-PO-CE-N-1P

Internet: www.festo.com/catalogue/...

15

Vacuum generators OVEM


Technical data
Ordering data and weight
Circuit symbol

Description

Electrical
switching
output

Nominal
size of laval
nozzle
[mm]

Weight

0.45
0.7
0.95
1.4

317
322

0.45
0.7
0.95
1.4
0.7
0.95
1.4

325
331

0.7
0.95
1.4
0.7
0.95
1.4

334

Part No.

Type

538828
538829
538830
539996

OVEM-05-H-B-QO-ON-N-2P
OVEM-07-H-B-QO-ON-N-2P
OVEM-10-H-B-QO-ON-N-2P
OVEM-14-H-B-QO-ON-N-2P

538825
538826
538827
539995
540009
540010
540011

OVEM-05-H-B-QO-OE-N-2P
OVEM-07-H-B-QO-OE-N-2P
OVEM-10-H-B-QO-OE-N-2P
OVEM-14-H-B-QO-OE-N-2P
OVEM-07-H-B-QO-OE-N-2N
OVEM-10-H-B-QO-OE-N-2N
OVEM-14-H-B-QO-OE-N-2N

540006
540007
540008
540003
540004
540005

OVEM-07-H-B-GO-OE-N-2P
OVEM-10-H-B-GO-OE-N-2P
OVEM-14-H-B-GO-OE-N-2P
OVEM-07-H-B-GO-OE-N-2N
OVEM-10-H-B-GO-OE-N-2N
OVEM-14-H-B-GO-OE-N-2N

[g]

NO Normally open
P-V with QS fitting,
R with open silencer

With ejector pulse,


P-V with QS fitting,
R with open silencer

2x PNP

2x PNP

2x NPN

With ejector pulse,


P-V with female thread,
R with open silencer

2x PNP

2x NPN

16

Internet: www.festo.com/catalogue/...

370

380
331
380

385
334
385

Subject to change 2014/10

Vacuum generators OVEM


Ordering data Modular products
Ordering table
Size

20

0
M Module No.

539074

Conditions Code

Vacuum generator
Nominal size of laval
nozzle

Vacuum generator with solenoid valve for vacuum on/off and manual override
[mm] 0.45
0.7
0.95
1.4
2.0
Ejector characteristic
High vacuum
High suction rate
Housing size/width
[mm] 20
Pneumatic connections
All connections with QS fittings
Supply/vacuum port with QS fittings, exhaust port with open silencer
All connections with G female thread
Supply/vacuum port with G female thread, exhaust port with open silencer
Prepared for supply manifold, vacuum port and exhaust port with QS fittings
Prepared for supply manifold, vacuum port with QS fittings, exhaust port with open
silencer
Normal position of the vacuum NO, normally open (vacuum generation)
generator
NO, normally open (vacuum generation) with ejector pulse
NC, normally closed (no vacuum generation)
NC, normally closed (no vacuum generation) with ejector pulse
Electrical connection
Plug M12 (5-pin)
0
O Vacuum sensor
(standard scale in bar)

Without vacuum sensor


1 switching output PNP
1 switching output NPN
2 switching outputs PNP
1 switching output PNP, 1 analogue output 0 10 V
1 switching output PNP, 1 analogue output 4 20 mA
2 switching outputs NPN
1 switching output NPN, 1 analogue output 0 10 V
1 switching output NPN, 1 analogue output 4 20 mA
inchHg

Alternative vacuum display

Enter
code

OVEM

OVEM
-05
-07
-10
-14
-20
-H
-L
-B
-QS
-QO
-GN
-GO
-PL
-PO

-B

-ON
-OE
-CN
-CE
-N

-N

-1P
-1N
-2P
-PU
-PI
-2N
-NU
-NI
-H

1
1
1

1 L, 1N, NU, NI, H


Not with nominal size of laval nozzle 2.0 mm

Transfer order code


539074
OVEM

2014/10 Subject to change

Internet: www.festo.com/catalogue/...

17

Vacuum generators OVEM


Accessories
Common supply manifold OABM-P
for vacuum generator
OVEM--PL/PO
Pneumatic connection 1: G
Type of mounting: Via through-hole
Material: Wrought aluminium alloy
Note on materials:
RoHS-compliant

1 Vacuum generator
2 Blanking plug
Dimensions
Number of device locations

H1

H2

H3

4
6
8

118
162
206

102
146
190

66
110
154

Tubing I.D. di as a function of total air consumption qnN


Total air consumption [l/min]
50
75
154
175
Tubing I.D.1) [mm]
2.5 2.9 3.8 4
Recommended tubing
PUN-4 PUN-6
1)

225

310

400

480

500

750

890

1,000

1,190

1,340

1,850

2,240

4.4

5.5

5.9

7.5

8.4

8.8

10

10.8 11

PUN-8

PUN-10

PUN-12

PUN-16

2,300

2,900
12

Technical data Internet: pun, pan


PAN-16

With a tubing length of 3 m

-H-

Note

The total air consumption of the fully


equipped common supply manifold
can be determined by adding the
individual consumption of each
generator used. Note that in the case

of vacuum generators with ejector


pulse (OE, CE), the individually set
values for the ejector pulse (duration
and intensity) can result in much
higher air consumption.

Ordering data and weight

Common supply manifold

1)

18

Number
of device
locations

CRC1)

4
6
8

2
2
2

Weight

Part No.

Type

549456
549457
549458

OABM-P-4
OABM-P-6
OABM-P-8

[g]
767
1,045
1,330

CRC2: Corrosion resistance class to Festo standard 940 070


Components with medium corrosion exposure. Externally visible components with significant decorative function in direct contact with normal industrial atmosphere or media such as coolants and lubricants.

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Vacuum generators OVEM


Accessories
Blanking plug OASC-G1-P
for common supply manifold
OABM-P-
Type of mounting: Screw-in
Max. tightening torque: 10 Nm
Materials:
Hollow bolt: Wrought aluminium alloy
Blanking cap: Steel
Seals: Steel, nitrile rubber
Note on materials:
RoHS-compliant
Ordering data

Blanking plug
1)

CRC1)

Weight
[g]

Part No.

Type

53

549460

OASC-G1-P

CRC2: Corrosion resistance class to Festo standard 940 070


Components with medium corrosion exposure. Externally visible components with significant decorative function in direct contact with normal industrial atmosphere or media such as coolants and lubricants.

H-rail mounting kit


OABM-H
for vacuum generator OVEM
Max. tightening torque for H-rail
mounting: 0.8 Nm
Material: Galvanised steel
Note on materials:
RoHS-compliant

1 Vacuum generator
2 H-rail TH-35-15

3 Screws M3x6 (enclosed)

Ordering data

H-rail mounting kit

2014/10 Subject to change

Weight
[g]

Part No.

Type

52

549461

OABM-H

Internet: www.festo.com/catalogue/...

19

Vacuum generators OVEM


Accessories
Ordering data Connecting cable NEBU-M12
Electrical connection

Part No.

Technical data Internet: nebu


Type

Straight socket, M12x1, 5-pin

Open end, 5-wire

2.5
5
10

541330
541331
554038

NEBU-M12G5-K-2.5-LE5
NEBU-M12G5-K-5-LE5
NEBU-M12G5-K-10-LE5

Straight socket, M12x1, 5-pin

Straight plug, M8x1, 4-pin,


rotatable thread

2.5

554036

NEBU-M12G5-K-2.5-M8G4

Angled socket, M12x1, 5-pin

Open end, 5-wire

2.5

567843

NEBU-M12W5-K-2.5-LE5

567844

NEBU-M12W5-K-5-LE5

Mounting type

Part No.

Technical data Internet: uoms


Type

Detenting

538436

UOMS-

Part No.

Type

9769

HRM-1

Ordering data Silencer extension UOMS


Design structure
Open silencer

Technical data Internet: hrm

Ordering data Mounting bracket HRM


Material
Steel galvanised

20

Cable length
[m]

Internet: www.festo.com/catalogue/...

Subject to change 2014/10

Você também pode gostar