Escolar Documentos
Profissional Documentos
Cultura Documentos
3
T2
30 $
14.00 [356]
30.0 $
12.00
[305]
10.00
[254]
T6
T10
T5
T3
16.00
[406.4]
14.00
[355.6]
TYP.
[406.4]
T9
REVISION
BY
28.00
[711.2]
SQ.
R. 2.00 [51]
TYP.
12.00
[304.8]
TYP.
24.00
[609.6]
SQ.
ITEM
LBS
KG
1090
494
12
PLAN 52 ASSY.
350
159
DRIVER
200
91
BARREL
562
255
SOLE PLATE
302
137
2516
1141
TOTAL
SOLE PLATE
- DETAIL -
TOP VIEW
COUPLING SPECIFICATIONS
MFR:
ITT
TYPE:
ADJUSTABLE SPACER
GUARD PROVIDED:
YES
SHAFT SEAL
103.38
[2626]
T8
64.00
[1626]
CONDUIT BOX
T10
SEE DETAIL-A
SHEET 2 OF 2
T1
38.75
[984]
1.00
[25.4]
PLAN 52 RESERVOIR
STAND MOUNTING
PLATE SHOWN ON
SAME ELEVATION AS
SOLE PLATE
T13
1.75
[44.5]
SOLE PLATE
REF.
T3
SEE
NOTE 6
19.59
[497.5]
SEE
NOTE 7
MFR.
27.00
[685.8]
DRIVER SUPPORT
T3
SUCT.
24.00
[609.6]
DISCH. HEAD
7.00
[177.8]
SEE
NOTE 3
T1
T5
DISCH.
13.50
[343]
T6
1.75
[44.5]
SOLE PLATE
66.44
[1687.5]
MODEL: VIC-T
DRAIN LINE
3/4 [19]
2.00
[50.8]
BARREL MTG.
FLANGE
K. ZIMMERMAN
DATE:
CUSTOMER
5-6-15
GOULDS PUMPS
CERTIFIED
A
DRAWING SCALE: NONE
DRAWN
GDP
5-4-15
CHECKED
KZ
5-5-15
APPROVED
KZ
5-6-15
DRAWING
THIRD ANGLE
PROJECTION
DATA
STAGES: 6
71.00
[1803]
BARREL
7.12
[181]
PUMP QTY:
SIZE:7AHC
T4
GE
TOTAL
PUMP LENGTH
T6
26.75
[679.5]
NO
DRIVER SPECIFICATIONS
T7
54.00
[1372]
T9
DATE
WEIGHTS (APPROXIMATE)
PUMP
PLAN 52
3/4" TUBING AND FITTINGS
PROVIDED BY ITT,
QTY. 2 AT 10 FT. [3 M] LONG
TYPICAL EACH PUMP
FIELD FITTED AND MOUNTED
BY CUSTOMER.
T12
LTR
16.00
[406.4]
T4
17.50
[444.5]
16.00 [406]
VIC-T
COPYRIGHT
2015
GAD315275
SHEET
1 OF 2
REV
NO
T1
SIZE
1/2"
T4
T5
6"
1-1/2"
T7
T8
3/4"
3/4"
T2
T3
T6
T9
3/4"
8"
3/4"
3/4"
T10
T11
3/4"
3/4"
T12
T13
3/4"
3/4"
DRIVER SUPPORT
10.75
[273,1 ]
1.
ADJUSTABLE
SPACER
COUPLING
ADJUSTING PLATE
SEE NOTE 4
PLAN 52
SYSTEM
PLAN 13
TUBING
T10
PLAN 52
TUBING
T11
ALIGNMENT
LUGS (4)
DISCH. HEAD
T2
NPT
NPT
NPT
STATUS
PLUGGED
FOR USE BY
CUSTOMER
PUMP DISCHARGE
BARREL VENT WITH VALVE
OPEN
OPEN
CUSTOMER
CUSTOMER
1
1
CLOSED
OPEN
PLAN 52 VENT
1
1
1
1
1
1
NPT
NPT
6.
9.
11. ONLY USE LIFTING LUGS ON DISCHARGE HEAD TO LIFT THE PUMP
12. ALL EQUIPMENT MUST BE INSTALLED,PIPED AND OPERATED IN
ACCORDANCE WITH API 686 AND THE INSTRUCTION MANUAL
PROVIDED WITH THE EQUIPMENT
CUSTOMER
CUSTOMER
ITT
CLOSED
CUSTOMER
CLOSED
CUSTOMER
FOUNDATION LOADS
4.
@ 103 $ F [39.4 $ C]
@ 103 $ F [39.4 $ C]
CUSTOMER
CUSTOMER
CUSTOMER
OPEN
OPEN
PLAN 52 DRAIN
5.
ITT
CUSTOMER
OPEN
OPEN
8.
OPEN
OPEN
PLAN 52 SUPPLY
PLAN 52 RETURN
NOTES
10. FOR PUMPS OVER 200HP[149 KW] THE PUMP ASSEMBLY HAS BEEN
DESIGNED SO THAT ITS NATURAL FREQUENCY RESPONSES AVOID
THE SPECIFIED MOTOR SPEED (OR SPEEDS) BY AN ADEQUATE
SAFTEY MARGIN.THE DESIGN ASSUMES A RIGID FOUNDATION
A
.125
ORIFICE
NPT
NPT
PURPOSE
MOTOR SUPPORT DRAIN
3.
7.
T9
QTY
1
T7
T13
CONNECTIONS TABLE
2.
T12
T8
MECHANICAL
SEAL
TYPE
NPT
Fz
Mz
C N
Mx
Fy
FLANGE
SIZE
6"
8"
Fx
Fy
Fx
My
LBS. (NEWTON)
Fz
Mx
My
Mz
FT.LBS.(NEWTON-METER)
560
700
460
1700
870
1300
[2491] [3113] [2046] [2304] [1179] [1762]
850
1100
[3780] [4893]
700
2600
1300
1900
[3113] [3525] [1762] [2576]
CUSTOMER
DATA
VIC-T
SHAFT
GOULDS PUMPS
A
DRAWING SCALE: NONE
DRAWN
GDP
5-4-15
CHECKED
KZ
5-5-15
APPROVED
KZ
5-6-15
DRAWING
THIRD ANGLE
PROJECTION
COPYRIGHT
2015
GAD315275
SHEET
2 OF 2
REV