Escolar Documentos
Profissional Documentos
Cultura Documentos
PLEASE NOTE:
This catalog contains only a fraction of all the Taco products and parts
available. For more information about, or to order other Residential and
Commercial Taco products, please contact Mondale and Associates, Inc.
Table of Contents
Circulator Sizing and Selection Guide 4-7
Hot-Link System 8
On Command Hot Water Recirculation 9
SmartPlus Circulation Pumps 10
Domestic Hot Water Circulation 11
3-Speed 00-Series Circulators 12
Priority Zoning Circulators 13
Variable Speed Delta T 00 Circulators 14
Bumble Bee High-Efficiency (VSC) 15
00-Series Cartridge Circulators 16
In-Line Circulator Series 17
1600 Series In-Line Pump 18
1900 Series In-Line Pumps 19
The Viridian High-Efficiency Circulators 20
Shut-Off Freedom Swivel-Flanges & Bronze Half-Unions 21
Freedom Flanges Including Bronze Half-Unions 21
iSeries Electronic Mixing Valves 22
5000-Series Mixing Valve 23
Differential Pressure Bypass Valve 24
FloodBreaker Whole House Water Shut-Off 24
Hydraulic Separator 25
Air Scoop 25
4900 Series Air Separators 26
Automatic Air Vents 27
Fuel Mizer 27
Zone Control Family (Switching Relays) 28
Zone Control Family (Zone Valve Controls) 29
Zone Sentry Zone Valves 30
Potable Water Zone Sentry Zone Valves 31
Geo-Sentry Zone Valves 31
Heat Motor Zone Valves 32
Flo-Check Valves 33
Cartridge Style Pressure Reducing Valve 33
Boiler Feed Pressure Reducing Valves 34
Low Water Cutoff Switch (LWCO) 34
Industrial Flow Switch 35
Compact Brazed Plate Heat Exchangers 36
Towel Warmers (Valves & Accessories) 37
Panel Radiators 38
Maxifold Radiant Heating Manifold 39
Fernox Products 40, 41
Reference Materials 42, 43
Step 2: Establish the resistance in the system that the circulator will need to overcome.
Determine the resistance or pressure drop in the piping, heat source, valves, fittings and any other devices in the system.
This resistance is measured in either psi or ft of head.
*Note: To convert psi to ft of head just multiply the psi x 2.31 OR divide ft of head by 2.31 to convert to psi
Let's break this down by the major components
Heat Source: This could be a boiler, water heater or heat exchanger. Consult the manufacturer for these pressure drops.
Piping: All pipe presents resistance to the fluid flowing through it. The faster the water flows, the greater the resistance.
Add the various lengths of pipe runs in the circuit served by the circulator. In the case of parallel circuits, like a radiant floor
manifold, use the loop with the greatest resistance, typically the longest length.
Fittings and Valves: Don't forget to add fittings and valves into the calculations. It is accepted practice to add up the
fittings and valves in the piping circuit then consult a fitting equivalent length chart to assign the appropriate pipe length to
the number of fittings or valves used. "Rule of Thumb": multiply the total footage of pipe times 1.5.
Miscellaneous Devices: Includes items like mixing valves, air separators, filters, wye-strainers, flow meters, heat
exchangers, coils or anything else the fluid flows through. Some items will have a pressure drop chart to refer to, others will
publish a Cv rating. Cv is short for coefficient of velocity (gpm that flows through the valve to produce 1 psi of pressure
drop). For example, a mixing valve with a Cv rating of 3.5 has a 1 psi pressure drop at 3.5 gpm of flow. If the flow is
different than the stated Cv rating, then use this formula to find the pressure drop that corresponds to the actual flow.
Example
System parameters are 10 gpm @ 11.3 ft of head.
To select the ideal curve, draw a line starting at 0
through the selection parameters. Chose the curve
that intersects somewhere in the middle of the third
curve. In this scenario, the pumps that satisfy the
requirements include 0011, 0012, 0013 or 0014.
Multi-Speed Circulators
The Viridian
Performance Field
Hot-Link System
The Taco Hot-Link System (HLS-1) for domestic hot water recirculation reduces the time it takes for hot water comfort to
reach showers and faucets. The Hot-Link System can save an average family up to 12,000 gallons of water per year and its
easy to retrofit to an existing plumbing system.
Features
Exclusive clean in place under sink valve
design
- Extends valve life
- Reduces customer calls to replace
plugged valves
Creates a domestic hot water recirculation
system without dedicated return loop
piping
Easy to retrofit to existing plumbing
system
Conserves water by greatly reducing the
time it takes to get hot water
Analog pump timer allows you to set the
system to work during peak hours or to
work continuously
Includes Hot-Link System Cartridge
Circulator, a Hot-Link bypass valve and
flex hoses
3 Year Warranty
Materials of Construction
Body..................................Nylon
Thermal Disk Actuator..........Bi-Metal
O-Ring Seals.......................EPDM
Integral Flow Check (IFC):
Body, Plunger.............Acetal
O-Rings.....................EPDM
Screen...............................304 SS
Stem.................................Nylon
Actuator Cartridge..............Stainless Steel
Braided Flex Hoses.............Stainless Steel
in.
in.
in.
in.
4-7/16
1-3/4
2-1/2
Motion
Sensor
(554-4)
RF Wireless
Starter Kit
(554-7)
Connection Type
HP
003-IQBC4
1/2 Sweat
1/40
003-IQB4
3/4 Sweat
1/40
006-IQBC4
1/2 Sweat
1/40
006-IQB4
3/4 Sweat
1/40
10
Model #
Connection Type
HP
006-IQST4
3/4 FNPT
1/40
Plumb n Plug
Model #
Accesories
Analog Timer Kit
265-1
265-3
Aquastat
563-2
563-2
Aquastat
265-1
Analog
Timer
265-3
Digital
Timer
System
Connection
24 Hr.
Analog Timer
7 Day
Digital Timer
Line Cord
Only
HP
Voltage
Amps
003-BC4
1/2 Sweat
003-BC4-PNP
003-BC4-8PNP
003-BC4-4PNP
1/40
115/60/1
0.43
003-B4
3/4 Sweat
003-B4-PNP
003-B4-2PNP
003-B4-1PNP
1/40
115/60/1
0.43
003-BT4
3/4 NPT
003-BT4-PNP
003-BT4-2PNP
003-BT4-1PNP
1/40
115/60/1
0.43
003-BC4-1
Union
003-BC4-1PNP
003-BC4-9PNP
003-BC4-5PNP
1/40
115/60/1
0.43
006-BC4
1/2 Sweat
006-BC4-PNP
006-BC4-4PNP
006-BC4-2PNP
1/40
115/60/1
0.52
006-B4
3/4 Sweat
006-B4-PNP
006-B4-2PNP
006-B4-1PNP
1/40
115/60/1
0.52
006-BT4
3/4 NPT
006-BT4-PNP
006-BT4-2PNP
006-BT4-3PNP
1/40
115/60/1
0.52
006-BC4-1
Union
006-BC4-1PNP
006-BC4-5PNP
006-BC4-3PNP
1/40
115/60/1
0.52
008-BC6
3/4 Sweat
1/25
115/60/1
0.84
008-SF6
Flanged
1/25
115/60/1
0.84
(IFC) Models
FLOW - M 3/H
1.5
2.0
2.5
FLOW - M 3/H
3.0
1
2
3
18
3.5
16
4.0
003
006
008
5.5
5.0
4.5
14
4.5
6.0
4.0
12
3.5
10
3.0
2
2.5
2.0
1.5
4
2
0
1.0
0.5
0
10
12
14
16
18
0.0
20
0.5
1.0
1.5
2.0
2.5
3.0
1
2
3
18
0.0
20
16
003-IFC
006-IFC
008-IFC
4.5
6.0
5.5
5.0
4.0
12
3.5
10
3.0
2.5
8
2
2.0
1.5
1.0
0.5
0
10
12
FLOW - GPM
11
4.0
4.5
14
FLOW - GPM
3.5
14
16
18
0.0
20
1.0
0.5
0.0
20
Three
speeds.
One
reputation.
Model #
*Flange Orientation
Flange Code*
0015-MSF3-IFC
0015-MSF3-1 IFC
0010-MSF2-IFC
Features
Sturdy 3-speed switch
Fine tune to system requirements
Highest performance & starting torque
in class
Heavy duty construction for longer life
Universal flange (0010 only)
Removable high-flow Integral Flow
Check (IFC)
Prevents gravity flow
Reduces installation costs
Improves pump performance
Replaceable cartridge design
Quiet, efficient operation
12
Thermostat
READY
Built-In
Transformer
and Relay
Features
00 reliability
Snap-in PC board
Removable, quick-connect low
voltage terminal strip
Integral Flow Check (IFC)
(optional)
UL listed
Simplified wiring
LED power light
100% factory tested
Works with other circulators
or zone valves
Universal thermostat
compatibility
Available in sizes 005 - 0014
Made in the USA
With Check
Valve
Flange
Configuration
005-ZF2-6
005-ZF2-2IFC
007-ZF5-9
007-ZF5-3IFC
007-ZF5-10
008-ZF6-6
008-ZF6-2IFC
009-ZF5-2
009-ZF5-1IFC
0010-ZF3-2
0010-ZF3-1IFC
0011-ZF4-2
0011-ZF4-IFC
0012-ZF4-4
0012-ZF4-IFC
S (1-1/2) Incl.
0012-ZF4-5
S (2) Incl.
0013-ZF3
0014-ZF1-2
0014-ZF1-1IFC
13
Operational Benefits
Eliminates velocity noise
Eliminates need for a pressure valve
Conserves energy
Pump always runs at minimum required
speed
Increases system performance
Achieves system design goals, even when
installed system varies from original
design
Pump automatically adjusts to current
system conditions
Spend less time figuring out pressure
drop (for proper pump sizing) when
servicing existing systems
Pump exercise
Delivers ideal BTU/hr heat transfer for all
styles of emitters
Available Models
Cast Iron
Stainless Steel
HP
008-VDTF6-1
008-VDTSF6-1
1/25
0011-VDTF4
0011-VDTSF
1/8
0013-VDTF3
0013-VDTSF
1/6
There are two applications that can benefit greatly from the use of a Taco Variable Speed Delta T Circulator:
Residential radiant floor heating systems often feature several zones on a single manifold, using manifold valve actuators,
designed around a 10 or 20 degree Delta T. The circulator is sized to provide enough flow and head pressure to satisfy all
zones calling at the same time. The same is true with circulators feeding multiple zones using zone valves. When using a
regular circulator and not all zones call, you get too much flow through the zone calling and can get velocity noise and poor
system performance. The Variable Speed Delta T Circulators automatically compensate by adjusting flow to make your
system perform optimally.
14
Features
High efficiency ECM Motor
reduces power consumption by
up to 85%
Fully programmable with 3
operating modes
Plug-in remote temperature
sensors included
LED displays real-time mode,
watt usage and GPM flow
360 swivel flange for mounting
flexibility
Nut capture feature on flanges
Integral Flow Check
(IFC) included in carton
Sensor kit with supply and
return sensors and tie wraps
GPM
GPM
GPM
WATTS
WATTS
WATTS
SP - Setpoint
dE-Delta-T, Differential
Temperature
(Variable Speed) mode
allows for a fixed system
temperature differential
(T) from 5F to 50F.
CP - Constant Power
(Fixed Speed) mode
allows for 4 fixed
circulator speeds.
15
Features
Standard high capacity output-compact
design
Quiet, efficient operation
Direct drive-low power consumption
Unique replaceable cartridge design-field
serviceable
Self lubricating
No mechanical seal
Unmatched reliability-maintenance free
Universal flange-to-flange dimension
Anti-condensate baffle (ACB) to protect
motor windings (0011, 0012, 0013)
Integral Flow Check (IFC) (optional)
Priority zoning relay (optional)
Most available in 230 volt
007-SF5 Stainless
Steel Circulator
Flange
Orientation
005-SF2
005-F2
005-F2-2IFC
Small Residential
006-F4
006-F6-IFC
Application
007-SF5
007-F7
007-F7-IFC
Residential
007-F5-5
007-F5-8IFC
Residential
008-SF6
008-F6
Radiant
008-SF6-2
00R-F6-1IFC
Radiant
009-SF5
009-F5
009-F5-IFC
0010-SF3
0010-F3
0010-F3-1IFC
Light Commercial
0011-SF4
0011-F4
0011-F4-2IFC
0012-SF4
0012-F4
0012-SF4-1
0012-F4-1
High Velocity
0013-SF3
0013-F3
0013-F3-1IFC
0014-SF1
0014-F1
0014-F1-1IFC
Medium Velocity
* Replacement Gaskets: Part #007-007RP for all models except 0012. For 0012 models, use 0012-020RP.
16
110 Series
Features
121-138 Series
Features
121-138 Series
Bearing Cartridge Design
Alloy steel shaft
Cupro-Nickel shaft sleeve
Two piece carbon/ceramic mechanical seal is
standard
Sealide-C/viton seal available for high
temperature and aggressive water
applications
Companion flanges provided in 2-12 or 3
(1) When specifying all bronze construction, add letter B after model number (i.e. 132B).
When specifying bronze fitted construction, add letter C after model number (i.e. 132C).
17
Pump Dimensions
Motor Chart
NOTE: Replacement parts and motors for
the 1600 pumps are available through
Mondale & Associates. Please contact us
for more information and pricing.
Features
Available in cast iron bronze fitted
construction or all bronze construction
Replaceable cooler running bearing
cartridge extends bearing life
Designed with permanently sealed
greased lubricated ball bearings, making
it virtually maintenance free
Cupro-nickel shaft sleeve
Standard mechanical seal
Maximum opening pressure of 175 psi
and maximum operating temperature of
300 F.
One piece enclosed impeller
Superior parts flexibility
Flanges included
18
Speed
Flange Size
1760
1-1/2
(2 OPT)
1911
3500
1760
1-1/2
(2 OPT)
1915
3500
1919
1760
1760
2
1935
3500
1941
1760
H.P.
1-PH
3-PH
1/4
1/3
X
X
X
X
1/2
1-1/2
Motor Assembly
Model #
HP
Voltage
121-199RP
1/4
115/208/230/60/1
121-200RP
1/4
200/60/3
121-201RP
1/4
208/230/460/60/3
131-192RP
1/3
115/208/230/60/1
131-193RP
1/3
200/60/3
1/3
208/230/460/60/3
1/3
1/2
X
X
X
X
131-194RP
132-169RP
1/2
115/208/230/60/1
3/4
132-170RP
1/2
200/60/3
1-1/2
132-171RP
1/2
208/230/460/60/3
2
3
X
X
X
X
132-189RP
1/2
575/60/3*
133-175RP
3/4
115/208/230/60/1
133-176RP
3/4
200/60/3
7.5
133-177RP
3/4
208/230/460/60/3
3/4
133-191RP
3/4
575/60/3*
138-166RP
115/208/230/60/1
1-1/2
138-167RP
200/60/3
N/A
138-168RP
208/230/460/60/3
1/2
3/4
138-195RP
575/60/3*
1
1-1/2
X
X
X
X
138-169RP
1-1/2
115/208/230/60/1
138-170RP
1-1/2
200/60/3
138-171RP
1-1/2
208/230/460/60/3
138-196RP
1-1/2
575/60/3*
138-173RP
200/60/3
7.5
138-174RP
208/230/460/60/3
138-187RP
575/60/3*
1-1/2
2
X
N/A
X
X
N/A
19
Pump Specifications
Max. Operating Pressure: 175 PSI
(12 bar)
Viridian web connections
are a snap!
Materials of Construction
Casing......Cast Iron
Impeller....Stainless Steel
Shaft........Stainless Steel
Bearing....Metal Impregnated Carbon
Operating Modes
Connecting
with
crossover
cable
Connecting
with
LAN cable
20
Features
Easy 1/4-turn open/close
operation
Positive shut-off, leak free design
Swivel flange allows 360 rotation
Solid brass construction
Chrome/brass valve ball
High quality Teflon seats
Full port ball valve for unrestricted
flow
Operating Data
Maximum WP =
150 psi / 600 WOG
Size
# of
Bolts
Standard
or High
Velocity
Bronze
NPT
Bronze
SWT
1/2"
Standard
110-522BSF
3/4"
Standard
110-523BSF
110-251SF
110-524BSF
110-525BSF
SWT
Isolation
Flange
NPT
Isolation
Flange
Pumps
Covered
SF-050S
SF-050T
005,007-0011,0013-0015,110-113,2400-10,20,45,50
110-251F
SF-075S
SF-075T
005,007-0011,0013-0015,110-113,2400-10,20,45,50
110-252SF
110-252F
SF-100S
SF-100T
005,007-0011,0013-0015,110-113,2400-10,20,45,50
110-253SF
110-253F
SF-125S
SF-125T
005,007-0011,0013-0015,110-113,2400-10,20,45,50
194-1540SF
194-1540F
SF-125S-0012
SF-125T-0012
0012,2400-30,40
Stainless
NPT
Ductile
Cast
Iron NPT
1"
Standard
1-1/4"
Standard
1-1/4"
HV
1-1/2"
Standard
110-526BSF
110-254SF
110-254F
SF-150S
SF-150T
005,007-0011,0013-0015,110-113,2400-10,20,45,50
1-1/2"
HV
194-1542SF
194-1542F
SF-150S-0012
SF-150T-0012
0012,2400-30,40
2"
HV
194-2124F
0012,2400-30,40
2"
HV
185-086B
185-086C
2400-60,65,70
2 1/2"
HV
185-112B
185-112C
2400-70/3
3"
HV
185-113B
185-113C
2400-70/3
21
Features
iSeries
Outdoor Reset
Connection Size
Cv
I075C2R-2
10.3
I100C2R-2
8.9
I075C3R-1
4.5
I100C3R-1
4.5
I075U3R-1
3.5
I100U3R-1
4.0
I075T4R-1
7.0
I100T4R-1
9.3
I125T4R-1
17.5
I075C2S-2
10.3
I100C2S-2
8.9
I075C3S-1
4.5
I100C3S-1
4.5
I075U3S-1
3.5
I100U3S-1
4.0
Multiple Temperature
System
22
Setpoint
Adjustable setpoint dial
(80F to 180F)
Selectable 15F setback
Optional boiler protection
(Set at 135F)
5123WH-N
Series
(Direct Mount)
5120 High
Flow Series
5000 Heating
Only Series
5120 Low
Flow Series
23
Typical Installation
3196-1
Operation
Ratings
Maximum Pressure: 200 PSI
The Bypass Valve uses an adjustable spring loaded seat that opens
and closes to allow flow through the valve. This opening and closing
is based on the system pressure applied to the valve seat and the
set point of the valve.
Features
FloodBreaker Models
24
Model #
Description
FB075-1
FB100-1
FB125-1
Hydraulic Separator
Tacos Hydro-Sep Hydraulic Separators are compact economical units that allow fast and efficient installation of primary/
secondary piping for many different boilers. Installing this unique Hydraulic Separator offers the additional advantages of
assisting in the removal of unwanted air and dirt particles, preventing their damaging affects on system components. It is
especially suitable for todays smaller boilers that tend to have a much higher flow resistance.
Typical Installation
HYDRAULIC
SEPARATOR
Features
Small space saving design
Rugged all copper construction
Specifications
Connections:
1 and 1-1/4 / Copper Sweat
Part #
Connection
Size
Max Flow
(GPM)
Maximum Pressure:
350 PSIG
HSEP100-1
1" Copper
Sweat
11
Maximum Temperature:
240F
HSEP125-1
1-1/4" Copper
Sweat
15
Media:
Water or Glycol / Up to 50%
Air Scoop
Taco Air Scoops enlarged design with internal baffles slows the water velocity in order to separate the air from solution. The
air scoop also provides an economic and noiseless way to integrate air elimination with the connection of either a plain steel
or diaphragm expansion tank.
Dimensions
Model #
Size
Cv
431-6
31
432-6
1-1/4
54
433-5
1-1/2
61
434-5
107
435-5
2-1/2
140
436-5
276
*437-1
600
Ratings
Maximum Operating Pressure: 125 PSI (862 kPa)
Features
25
Features
4900 Air Separators Were Proved To Be Better!
Tests carried out at the Delft Technical University have
unequivocally proved that 4900 Air Separators remove all
micro-bubbles from 15-20 microns and up. This is three
times better than comparable high performance Air
Separators!
How It Works
Pall Rings
Available Models
Water Level
Size
NPT
Sweat
3/4"
49-075T
49-075C
1"
49-100T
49-100C
1-1/4"
49-125T
49-125C
1-1/2"
49-150T
49-150C
49-200T
N/A
Ratings
Maximum Operating
Pressure: 150 psi
Maximum Operating
Temperature: 240F
Air Removal
Minimum Operating
Temperature: 25F
Media:
Water or Water/Glycol
Maximum Velocity:
5 feet/sec
26
419-1
409-3
400-3
418-4
Dimensions
Product
Number
Description
Bubble
Breaker
Max. System
Conditions
Max. Venting
Pressure
417-3
400-4
Hy-Vent
1/8 NPT
No
125 psi
1/8 NPT
Yes
416-2
50 psi
Slim-Line Hy-Vent
1/8 NPT
Yes
115 psi
426-3
Hy-Vent
1/4 NPT
Yes
50 psi
418-4
No
50 psi
419-1
Hy-Vent
No
150 psi
409-3
3/4 NPT
No
150 psi
414-1
Waste Connector
1/4 NPT
Fuel Mizer
The FuelMizer (SR501-OR) is a microprocessor-based control designed to regulate the supply water temperature of a single
boiler, based on the outdoor temperature. The FuelMizer is a boiler reset control and switching relay in one unit; it is ideal
for retrofit application, but may also be used in new installations as well.
Features
Full outdoor boiler reset
control
Can control system or
zone valve circulator
Over-ride of outdoor reset
when DHW tank is calling
Easy to install and set; will
not affect boilers warranty
Front mounted LED lights
for full diagnostic
information
Ideal for retrofit applications
of just about any cast iron
boiler
Typical energy savings is
about 14% with some
customers experiencing up
to 30%
27
More Features
External indicator lights provide instant
diagnostic feedback, making a snap of
service calls or new installation start-ups.
All switching relays are UL listed, and are
compatible with conventional and
programmable thermostats.
For those larger jobs, the EXP Switching
Relays can be expanded up to 120 zones
(20 zoning panels) with priority. Taco
Switching Relays are available in one,
two, three, four and six zones.
Features
Dip Switch
Settings
Switching Relays
Product #
Description
SR501
SR501-OR
SR501-HC
SR502
SR503
SR504
SR506
Description
SR501-EXP
SR503-EXP
SR504-EXP
SR506-EXP
28
External Diagnostics
Its no longer necessary to remove the box cover to troubleshoot the
system. External visible indicator lights show full functionality of all
products wired to the zone valve controls. When the thermostat calls
for heat, both the appropriate zone valve and yellow indicator lights
are energized. When the zone valve is fully opened, the end switch
relay and red indicator light is then energized.
Features
Number
of Zones
Transformer
Rating
ZVC403
3-zone w/priority
40 VA
ZVC404
4-zone w/priority
40 VA
ZVC405
5-zone w/priority
ZVC406
6-zone w/priority
Transformer
Voltage
Width
Height
Depth
2-3/4
2-3/4
80 VA
80 VA
Number
of Zones
Transformer
Rating
ZVC404EXP
4-zone w/priority
80 VA
ZVC406EXP
6-zone w/priority
80 VA
Transformer
Voltage
Dimension of Enclosure
Width
Height
Depth
* The pump end switches are rated 1/6 hp, 5 amps at 120 VAC. The main and
priority end switch connections are rated 24 VAC, 1 amp. All thermostat and zone
valve connections supply a 24 VAC class 2 output.
Description
PC700
PC702
PC705
29
Features
Simple to install in any direction or
orientation
Up to 12 zone valves per 40 VA
transformer
Uses only 1.44 watts while power is
on
High flow, low headloss
characteristics
Universal compatibility
Push-button engage and disengage
design eliminates gear and spring
damage
Plug-in screw terminals for easy
installation and operation
External LED status light
Fewer moving parts for extended
product life
Specifications
30
.25% Lead
Description
CV
Size
V050CD2ZA024AQ4A1
4.9
1/2 SWT
V075CD2ZA024AQ4A1
10.3
3/4 SWT
V050CD2ZB024AQ4A1
4.9
1/2 SWT
Z075CD2ZB024AQ4A1
10.3
3/4 SWT
31
Features
Geothermal Valves
(Models 5101G, 556G, 557G)
Designed for high head, open system zone
Rugged dependability
Silent operation
Description
556-G3
557-G3
5101-G2
555-173RP
Patented construction
Easy to install
Manual open (bypass) lever
24 VAC powered with isolated end
switch
100% factory tested
Made in the USA
560 Series
(560, 561, 562)
A 3-Way bypass version of the 570 Gold
Series. This valve is used to control the flow
to a fan coil or terminal heating unit.
Available Models 560
Model #
Description
561-5
562-5
555-154RP
555-151RP
Description
571-2
572-2
573-2
555-050RP
32
Flo-Chek Valves
Taco Flo-Cheks are used in a forced hot water heating system to prevent gravity circulation during periods when the boiler
is hot but the space heating zone is not wanted. This makes it possible for the use of the heating boiler to maintain domestic
hot water year round. In systems with multiple circulator zones, Flo-Cheks allow heat to flow only into the zones that are
calling for heat. Also, the thumb screw can be manually opened for gravity feed applications if the main circulator stops
operating.
Specifications
Product
Number
Size
Body
219-4
3/4
Bronze
241-4
Bronze
218-3
3/4
C.I.
220-6
C.I.
221-6
1-1/4
C.I.
222-6
1-1/2
C.I.
223-5
C.I.
Features
Automatic pressure reset from fast fill
Easy external dial-up pressure setting
Set pressure indicator
Simple serviceability with the unique
one piece cartridge
Internal check allows the cartridge to
be replaced without draining the
system
Integral strainer
ASSE 1003
Specifications
Convenient One-Piece
Cartridge
3350-T3
Media: Water
33
Features
Fast Fill rate on all models
Exclusive Fast Fill Lever Lock
Built-In check to prevent emptying the
system if incoming pressure fails
Adjustable set pressure of 10 to
25 psi
Pressure setting adjustment separated
from Fast Fill Lever for easy, fast
adjustment
Performance Data
PRESSURE REDUCING VALVES
Maximum Fluid Temperature:
212F (100C)
Maximum Supply Side Pressure:
100 psi (689kpa)
Set Pressure Range:
10-25 psi (69-172kpa)
Factory Setting of System Side:
12 psi (83kpa)
DUAL CONTROLS
Connection Sizes
Model #
Description
329-4
329-T4
335
334-3
334-T3
Features
LF Ordering
34
IFS Ordering
3 year warranty
Fluorosilicone seal
superior to competitors
mechanical bellows
Models
IFS01/02/H1/H2
Models
IFSWS
Notes:
1. Typical flow rates for 1 to 1-1/2 pipe sizes are
averages which may vary approximately 1 GPM with
the use of a bronze reducing tee.
2. Typical flow rates for 2 to 8 pipe sizes are
averages which may vary approximately 10%
GPM with the use of a 1 weldolet.
(*) Flow rates for these sizes are calculated.
1 1-1/4 1-1/2
2-1/2 3 4 5 *
8 *
50
70
210
40
60
190
50 70 120
180
410
45 65 105
160
380
Minimum
Flow
4.5
Adjustment Increase
4.5
6.0
7.5
13.5
18 35
Minimum
Flow
3.5
Adjustment Decrease
3.5
5.0
5.5
9.5
13 25
Maximum
Flow
9.5
Adjustment Increase
10
13.5
20.0
29
Maximum
Flow
7.0
Adjustment Decrease
8.5
10.5
18.5
26
35
Features
Made from stainless steel and manufactured
with the highest of quality
Delivered with full traceability and verified
functionality
Approved by leading independent international
bodies such as PED, UL, KHK, CSA
Manufactured in the USA and Sweden
Part #
Description
BTUh
B10TH-BKT
B10THX-8FB
65,000
B10THX-10FB
90,000
B10THX-12FB
110,000
B10THX-16FB
150,000
B10THX-20FB
185,000
B10THX-24FB
220,000
B10THX-30FB
270,000
B10THX-36FB
320,000
B10THX-40FB
345,000
B10THX-50FB
405,000
B10THX-60FB
455,000
B35HX30
610,000
B35HX50
920,000
(Double Wall)
Part #
Description
BTUh
B16DW x 10
B16DW x 10 / 1P-SC-S4*
1" NPT
60,000
B16DW x 30
B16DW x 30 / 1P-SC-S4*
1" NPT
205,000
B16DW x 50
B16DW x 50 / 1P-SC-S4*
1" NPT
350,000
B16DW x 70
B16DW x 70 / 1P-SC-S4*
1" NPT
480,000
Features
5-Year Limited Warranty
Designed for hot water (no steam)
and operating pressures of up to 120 psi
and temperatures of up to 220 F
Supply and return water tappings (1/2
fem) located at bottom of vertical tubes
and reversible
Standard 1/8 air bleeder installed at top
of right hand vertical tube
Mounting brackets included
Standard finish is white epoxy powder
coating to RAL 9016 which can be easily
painted any color
Specifications
Part #
DN43224
DN44824
DN47124
Height
x Length
BTU Outputs
@ 180 F
32" x 24"
48" x 24"
71" x 24"
1,760
2,640
3,960
Product Description
H-1082
H-1365
Thermostat (WHITE)
H-5813
H-5814
H-5933
H-5934
H-6062
H-6063
H-6864
H-F6674
H-WKL
Tubing Cover
37
Panel Radiators
More comfort, less wall space! Built in Germany to the highest design and quality standards, DiaNorms panel radiation
products combine comfortable radiant heat with individual room temperature control. DiaNorm radiators take up to
75% less wall space and generate comfortable heat at lower water temperatures than baseboard heating products.
DiaNorm radiators are built to the highest quality standards and carry quality seals such as DIN, TV, EN, RAL, NF etc. The
factory has been one of the first to receive ISO 9002 Certification. If properly installed, DiaNorm radiators come with a 5
-year Limited Warranty.
Features
Made of high quality 1.25mm FePO1 steel
Epoxy powder coating, white finish to RAL 9010
Water connections are not exposed but
located at bottom
Can utilize thermostatic radiator valve for
non
-wire zoning
Can be piped with plastic PEX Tubing,
making it much easier to install than copper
Stocked
Non-Stocked
Part #
DN20848
DN20864
DN20872
DN21224
DN21236
DN21248
DN21616
DN21624
DN21636
DN21648
DN22016
DN22024
DN22036
DN22048
DN22416
DN22424
DN22436
DN22448
DN22472
DN23616
DN23636
Height x Length
8" x 48"
8" x 64"
8" x 72"
12" x 24"
12" x 36"
12" x 48"
16" x 16"
16" x 24"
16" x 36"
16" x 48"
20" x 16"
20" x 24"
20" x 36"
20" x 48"
24" x 16"
24" x 24"
24" x 36"
24" x 48"
24" x 72"
36" x 16"
36" x 36"
3757
5005
5633
2317
3477
4637
1931
2900
4347
5797
2368
3555
5330
7107
2757
4135
6203
8271
12409
3862
8690
Part #
DN21264
DN21272
DN21664
DN21672
DN22064
DN22072
DN22464
DN23672
Height x Length
12"
12"
16"
16"
20"
20"
24"
36"
x
x
x
x
x
x
x
x
64"
72"
64"
72"
64"
72"
64"
72"
6183
6954
7728
8697
9475
10663
11031
17381
DN11616
DN11624
DN11636
DN11648
DN11664
DN11672
DN12016
DN12024
DN12036
DN12048
DN12064
DN12072
DN12416
DN12424
DN12436
DN12448
DN12464
DN12472
38
Height x Length
16"
16"
16"
16"
16"
16"
20"
20"
20"
20"
20"
20"
24"
24"
24"
24"
24"
24"
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
16"
24"
36"
48"
64"
72"
16"
24"
36"
48"
64"
72"
16"
24"
36"
48"
64"
72"
1143
1713
2569
3426
4569
5142
1396
2092
3139
4187
5582
6278
1638
2457
3685
4913
6551
7370
Features
Stainless Steel
Radiant Heating
Manifold
Extension
Valves
Product #
Description
H - 4172
For 2 Branches
H - 4173
For 3 Branches
H - 4174
For 4 Branches
H - 4175
For 5 Branches
H - 4176
For 6 Branches
H - 4177
For 7 Branches
H - 4178
For 8 Branches
Extension Kit
Extension Flow
Meter
Product #
Description
H - 4172 EXT
H - 4173 EXT
H - 4174 EXT
Product #
Description
H - 4175 EXT
H - 2496
H - 4176 EXT
Accessories
Product #
Description
Product #
Description
H - 6848
H - 2496
H - 6849
3/8 PEX
H - 4004
H - 6850
1/2 PEX
H - 4008
H - 6851
5/8 PEX
H - 6852
3/4 PEX
H - 4700
H - 6864
H - 6815
H - 6950
1/2 Pex-Al-Pex
H - 4900
Thermometers
39
FERNOX Products
Fernox has developed a reliable and trusted product portfolio covering everything from water treatment cleaners and
inhibitors to solders and fluxes. These products have been used successfully in Europe for many years and are approved for
use by most boiler manufacturers. Theres specialist equipment such as powerflushing machines and scale reducers, plus
renewable technologies including heat transfer fluids and underfloor corrosion inhibitors. Fernox also produces some
quick-fix products for emergency repairs.
Environmentally responsible
All of Fernoxs products are formulated and packaged in a way that aligns with the companys corporate and social
responsibility policy. Each product is designed to contribute to maximizing energy efficiency, reducing both fuel consumption
and the carbon footprint of its business, industrial and domestic customers.
Protector
F1 Express
Part #: F-59900
Boiler Noise
Silencer F2
Express
Leak Sealer
F4 Express
Part #: F-59903
Part #: F-59901
Part #: F-59902
efficiency
Part #: F-57880
Long term
contaminants
Fits vertical and horizontal pipe work
Removes sludge,
flux and debris
LIQUID PRODUCTS
For Systems up to 26 Gallons (1-Pint Sizes)
Protector F1
Cleaner
F5 Express
280ml
Boiler Noise
Silencer F2
Part #: F-57881
protection
against corrosion
and limescale
Multi-metal safe
Reduces boiler
Cleaner F3
Leak Sealer F4
Part #: F-57882
Removes sludge,
scale and debris
Restores heating
efficiency
40
noise
Improves heat
transfer efficiency
Part #: F-57883
FERNOX Products
COMMERCIAL / For HVAC Commercial Systems
Alphi-11
5 Gallons
Protector F1
2.6 Gallons
Cleaner F3
2.6 Gallons
Part #: 155738-005
Part #: F-59700
Part #: F-59701
55 Gallons
Part #: F155738-055
Combined anti-freeze
and protector
Protects against
TDS Meter
Part #: F-62089
measurement of
total dissolved solids
Ideal for use when
powerflushing
Protector Test
Kit
Part #: F-57875
Part #: F-57879
analysis of the
concentration of
all Fernox protectors
Kit includes
sufficient reagent for
25 system checks
The Flexconsole
The Flexconsole is the only easy and professional way to install your thermal expansion tank. Unlike the way most expansion
tanks are installed, the Flexconsole provides a solid mounting point and eliminates all stress on the water lines. Flexconsole
installations look more professional and service is a breeze with both hands free to make repairs! When properly mounted on
solid walls, or on a stud behind drywall, the Flexconsole is designed to hold a steel thermal expansion tank with a volume of
up to 6.6 US gallons.
flexconsole::usastandard
For use on closed hydronic systems
(Standard)
flexconsole::usastainless
FC-97975
Flexconsole Models
Model #
Description
Type
FC-97975
Standard
FC-97976
Stainless Steel
41
(Stainless)
FC-97976
Ohms Law
42
Maximum Flow
Rate (GPM)**
Heat Carrying
Capacity (BTUhr)
1/2
3.2
32,000
3/4
6.5
65,000
10.9
109,000
1-1/4
16.3
163,000
1-1/2
22.9
229,000
39.6
396,000
Spacing Factors
(for use with in-floor tubing)
GPM
3/8
1/2
5/8
3/4
8.0
11.31
2.48
0.93
0.44
0.12
7.8
10.61
2.32
0.87
0.41
0.12
7.5
9.94
2.18
0.81
0.39
0.11
7.3
9.29
2.03
0.76
0.36
0.10
7.0
8.66
1.90
0.71
0.34
0.09
6.8
8.05
1.76
0.66
0.31
0.09
6.5
7.46
1.63
0.61
0.29
0.08
6.3
6.90
1.51
0.57
0.27
0.08
6.0
6.36
1.39
0.52
0.25
0.07
5.8
5.84
1.28
0.48
0.23
0.06
5.5
5.34
1.17
0.44
0.21
0.06
5.3
4.87
1.07
0.40
0.19
0.05
5.0
4.42
0.97
0.36
0.17
0.05
4.8
3.99
0.87
0.33
0.15
0.04
4.5
3.58
0.78
0.29
0.14
0.04
4.3
3.19
0.70
0.26
0.12
0.03
4.0
2.83
0.62
0.23
0.11
0.03
3.8
2.55
0.56
0.21
0.10
0.03
3.6
2.29
0.50
0.19
0.09
0.03
3.4
2.04
0.45
0.17
0.08
0.02
3.2
1.81
0.40
0.15
0.07
0.02
3.0
1.59
0.35
0.13
0.06
0.02
2.8
1.39
0.30
0.11
0.05
0.02
2.6
1.19
0.26
0.10
0.05
0.01
2.4
1.02
0.22
0.08
0.04
0.01
0.86
0.19
0.07
0.03
0.01
Spacing
4 O.C.
3.10
6 O.C.
2.10
2.2
8 O.C.
1.60
2.0
0.71
0.15
0.06
0.03
0.01
9 O.C.
1.38
1.8
0.57
0.13
0.05
0.02
0.01
12 O.C.
1.05
1.6
0.45
0.10
0.04
0.02
15 O.C.
0.83
1.4
0.35
0.08
0.03
0.01
18 O.C.
0.70
1.2
0.25
0.06
0.02
0.01
24 O.C.
0.55
1.0
0.18
0.04
0.01
0.01
36 O.C.
0.37
0.8
0.11
0.02
0.01
48 O.C.
0.28
0.6
0.06
0.01
0.01
0.4
0.03
0.01
0.2
0.01
0.0
2.31
Head (Ft.)
43