Você está na página 1de 2

7

DESIGN DATA

I CIRCULAR SEAM

II

BUILT IN ACCORDANCE TO API-12F CONSTRUCTION STANDARDS.


750 BBL 15'-0" [4572mm] DIA. x 24'-0" [7315mm] HIGH SHELL WALL,
BUTT JOINT, STEEL, ATMOSPHERIC, STORAGE TANK
ROOF MATERIAL:
FLOOR MATERIAL:
SHELL MATERIAL:
FLANGE MATERIAL:
PIPE MATERIAL:
COUPLING MATERIAL:
FIRETUBE:
D WELD FITTINGS:

A-36
A-36
A-36
A-105N
A-106B
A-105N
N/A
SA-234 WPB

AIR TEST:
HYDRO TEST:
SERVICE:
CORROSION ALLOWANCE:
LABELLED/REGISTERED:
RADIOGRAPHY:
SHIPPING WEIGHT:

FLOOR DIAMETER:
SHELL DIAMETER:
ROOF CUT RADIUS:
ROOF WEDGE CUT:
SHELL CUT LENGTH:
ROOF THICKNESS:
SHELL THICKNESS:
FLOOR THICKNESS:

VERTICAL
SEAM

III

ROOF/FLOOR
SEAM

SHELL TO
FLOOR

IV

ROOF TO
SHELL
3/16"

182 1/2" [4636]


180" [4572]
91 1/4" [2318]
7 13/16" [199]
47'-1 1/2" [14364]
3/16"
3/16"
1/4"

12 oz.
DESIGN PRESSURE:
8 oz.
N/A
OPERATING PRESSURE: ATMOSPHERIC
SWEET
NONE
NO
N/A
16900 lbs / 7668 kg

3/16"
3/16"

FLANGE/FITTING
SLIP-ON FLANGE
PLATE FLANGE
NOZZLE THRU
COUPLING THRU
X
VII
IX
VIII
TO PIPE
TO PIPE
TO PIPE
ROOF OR SHELL
ROOF OR SHELL

VI

O/S PROJ.

60
ROOF PL
SHELL PL

ROUND
WT
WT

ROUNDED
CORNERS

3/16"
3/16"

3/16"
3/16"

3/16"
3/16"

ROUND
CORNERS

WT
WT-WALL THICKNESS

XI

COUPLING TO
ROOF

XII

3/16"

1" FOR LI
1/4" FOR
FLOAT
GUIDE

SURFACE PREP-INTERNAL: NONE


NONE
INTERNAL COATING:
SURFACE PREP-EXTERNAL: SANDBLAST AS PER SSPC -SP14 TO SHELL AND ROOF
ONE(1) COAT OF MARINE ENAMEL TO SHELL AND ROOF
EXTERNAL COATING:
COLOR: CLOVERDALE ULTRAFAB TAN

OTHER

UNLESS
OTHERWISE
DETAILED
WELDS ARE 3/16"
CONTINUOUS
FILLET WELDS

NOZZLE SCHEDULE
TAG TAGs
N3
N4
N5
N6
N7
N8
N9
N10
N11
N12
N13
C1 a,b
C2
C3
LI
M1
TH

GENERAL NOTES:

SIZE
10" [273]
2" [60]
4" [114]
3" [89]
4" [114]
3" [89]
4" [114]
3" [89]
3" [89]
3" [89]
3" [89]

RATING
-

1/2" [21]
3/4" [27]
2" [60]

CL 3000
CPLG
CL 3000 1/2 CPLG
CL 3000 1/2 CPLG

CL
CL
CL
CL
CL
CL
CL
CL
CL
CL

150
150
150
150
150
150
150
150
150
150

TYPE
FAB'D
RFSO
RFSO
RFSO
RFSO
RFSO
RFSO
RFSO
RFSO
RFSO
RFSO

1 1/2 [48]
CL 3000 1/2 CPLG
API
24 1/2" X 36 1/2" [622 X 927]
12F
8" [219]
FAB'D

SERVICE
VENT C/W GOOSENECK AND BIRDSCREEN
HIGH FILL
INLET
DRAIN C/W BLIND FLANGE
EQUALIZING LINE
TOP OVERFLOW C/W 3x2 REDUCING HUB BLIND
OUTLET C/W BLIND AND DOWNCOMER
INLET
INLET
TOP OVERFLOW
TOP OVERFLOW C/W 3x2 REDUCING HUB BLIND

REPAD
NO
NO
NO
NO
NO
NO
NO
YES
YES
NO
NO

FLOAT GUIDE WIRES


LEAK DET. /IND.
SPARE
LEVEL INDICATOR C/W REDUCER BUSHING TO 3/4"
MANWAY/CLEANOUT
THIEF HATCH

ORIENTATION
CENTER
D - 45 - 70 13/16" [1799]
C - 65 - 102 5/16" [2599]
C - 0 - 0" [0]
C - 67.5 - 106 1/4" [2699]
C - 20 - 31 1/2" [800]
D - 0 - 0" [0]
A - 0 - 0" [0]
C - 0 - 0" [0]
A - 0 - 0" [0]
C - 20 - 31 1/2" [800]

NO
NO
NO

ON ROOF
0'-6" [152]
17'-0" [5182]

SEE ORIENTATION DWG


D - 20 - 31 1/2" [800]
A - 50 - 78 11/16" [1999]

13/16" EXT.
3/4" EXT.
1 7/16" EXT.

XI
IX
IX

NO
NO
NO

ON ROOF
2' -6" [762]
ON ROOF

C - 51 - 80 1/4" [2039]
B - 45 - 70 13/16" [1799]
C - 35 - 55 1/16" [1399]

1 5/16 EXT.
3" INT. / 3" EXT.
5" EXT.

XI
X
VIII,X

CLIENT ID NUMBERS ADDED TO DATA PLATES

1. DIMENSIONS ARE IN IMPERIAL UNITS WITH SI UNITS IN SQUARE BRACKETS [mm].


2. ALL NOZZLE PROJECTIONS GIVEN ARE ALONG THE NOZZLE CENTERLINE.
3. ALL FLANGE RATINGS TO BE ASME B16.5A - 1998
ORIENTATION IS MEASURED
CLOCKWISE FROM THE
INDICATED POSITION.
A

28
TH
12
C1

13
TOP OF CAGE

1'-3"
[381]

24

12

BOTTOM OF SUPPORT

QUAD.
A

QUAD.
C

QUAD.
B

A - 0 - 0"[0]
9

15

C
ARC LENGTH MEASURED
ALONG OUTSIDE OF SHELL

N12

QUADRANT - ANGLE - ARC LENGTH


eg. C - 65 - 105 11/16" [2685]

N10

1'-0"
[305]

N4

TOP OF SHELL

a,b

LI

14

QUAD.
D

N3

27'-6"
[8382]

19

FULL QUAD = 90 = 141 11/16" [3598]

24'-0"
[7315]

D - 45 - 70 13/16" [1799]

22'-2 3/8"
[6766]

0'-6"
[152]

26

23'-0"
N8
[7010]

9
26

14

17

2
C3

21'-9" 6
[6629]
N13 18
7
D - 20 - 31 1/2" [800]

17'-0"
C3
[5182]
16'-3"
[4953]

C2

26

11'-9"
[3581]

N9

22

26
23

N5 0'-7 1/2"
[191]

N3
13

12
7'-3"
[2210] 6

1'-9"
[533]

2'-6"
11 M1
[762]

MANWAY

26

26

2'-2 3/8"
BOTTOM OF SUPPORT
[670]

23 N9

M1

22 N10 19 N11 20

1
C - 51 - 80 1/4" [2039]

12

11

b
0'-7 1/2"
[191]

0'-6"
C2
[152]

0'-5"
N6
[127]

16

C - 35 - 55 1/16" [1399]

B - 45 - 70 13/16" [1799]

TH
N8
17

N13
18
C - 20 - 31 1/2" [800]

N6
16
N11
20

21
9

0'-3"
[76]BOTTOM OF DOWNCOMERS

0'-0"
[0]

28

0'-4 1/2"
N5
[114]

0'-10 5/8"
BOTTOM OF LADDER
[270]
DATUM: TOP OF FLOOR

LI

CENTER

C1 a
C1

3'-0"
N7
[914]

B - 19.05 - 30"[762]

N7

C - 65 - 102 5/16" [2599]

DATA PLATE

C - 0 - 0"[0]

0'-0"
[0] DATUM: TOP OF FLOOR

10

0'-6 1/4"
[158]

SER #

CLIENT ID #

721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741

TK-102-12302
TK-102-12303
TK-102-12304
TK-102-12305
TK-102-12306
TK-102-12307
TK-102-12308
TK-102-12309
TK-102-12310
TK-102-12311
TK-102-12312
TK-102-12313
TK-102-12314
TK-102-12315
TK-102-12316
TK-102-12317
TK-102-12318
TK-102-12319
TK-102-12320
TK-102-12321
TK-102-12322

1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2

742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762

TK-102-12323
TK-102-12324
TK-102-12325
TK-102-12326
TK-102-12327
TK-102-12328
TK-102-12329
TK-102-12330
TK-102-12331
TK-102-12332
TK-102-12333
TK-102-12334
TK-102-12335
TK-102-12336
TK-102-12337
TK-102-12338
TK-102-12339
TK-102-12340
TK-102-12341
TK-102-12342
TK-102-12343

ORIENTATION

15'-0" ID
[4572]
A

ITEM QTY
DESCRIPTION
1
1 CPLG, HALF THD - CLASS 3000 1 1_2
ANGLED C/W REDUCER BUSHING 3_4
2
1 CPLG, HALF THD - CLASS 3000 2 C/W PLUG
3
1 CPLG, HALF THD - CLASS 3000 3_4 CW
PLUG
4
1 DATA PLATE WITH BRACKET
5
2 FLOOR HALF - STEEL, SHEET 1/4" - DIA
182.5[4636]
6
5 GAUGE BOARD BRACKET (SUPPLIED BY
OTHERS)
7
1 GUARD RAIL ASSY W .25 AC CABLE 750 STD
1 LADDER, OH&S COMPLIANT (PIP STF05501)
8
9
4 LUG, LIFTING 6 X 12 X 3_8
10
1 LUG, TAIL ASSY
11
1 MANWAY-24 X 36 CW HINGED DOOR
12
1 MECHANICAL LEVEL GAGE ASSY 24FT R90
SW FLOAT GUIDE
1 NOZZLE, 10IN SHOP 4.25 TL W SHOP
13
FLANGE, GOOSENECK, BIRDSCREEN
14
1 NOZZLE, 2IN RFSO 7.25 IN TL
15
1 NOZZLE, 3IN RFSO 6IN TL
16
1 NOZZLE, 3IN RFSO 6IN TL C/W BLIND
17
1 NOZZLE, 3IN RFSO 6IN TL CW HUB BLIND
TAPPED 2IN
1 NOZZLE, 3IN RFSO 6IN TL CW HUB BLIND
18
TAPPED 2IN
19
1 NOZZLE, 3IN RFSO 6IN TL W REPAD 6332
20
1 NOZZLE, 3IN RFSO 6IN TL W REPAD 6332
1 NOZZLE, 4IN RFSO 6.5 IN TL
21
1 NOZZLE, 4IN W 2 RFSO 10 TL CW BLIND &
22
DOWNCOMER 33
23
1 NOZZLE, 4IN W 2 RFSO 12IN TL CW
DOWNCOMER 33
24
1 ROOF - STEEL, SHEET 3/16 DIA 180
25
3 SHELL-STEEL SHEET 3/16" - 96 - DIA 180
4 SHIPPING PAD ASSY
26
1 SKID, 750 - DIA 15 - W6x15
27
28
1 THIEF HATCH, WENCO TH8 (8 oz P - 0.4 oz
V) SW

DRAWINGS MUST BE SIGNED AND APPROVED BEFORE


OUTLAW WELDING WILL BEGIN CONSTRUCTION

PROJECT:

APPROVED FOR CONSTRUCTION

RARE

ISSUE FOR CONSTRUCTION AS NOTED


REVISE AND RESUBMIT FOR APPROVAL

ELEVATION REPRESENTATION

SIGN:

MONTH:
YEAR:

ANY CHANGES MADE AFTER APPROVAL MAY RESULT IN SIGNIFICANT


DELAYS AND/OR ADDITIONAL COSTS TO THE PROJECT

OILFIELD SERVICES CORP.

DWG SET:

A-105N
A-105N

770
4274

A-36
A-36

694
1036
N/A

ASSEMBLY
A-36
A-36
A-36
A-36
SWEET

4961
6240
5831
250
727
6056

ASSEMBLY

6334

ASSEMBLY
ASSEMBLY
ASSEMBLY
ASSEMBLY

6223.1
2039.2
2386
6231

ASSEMBLY

6231.1

ASSEMBLY
ASSEMBLY
ASSEMBLY
ASSEMBLY

6333
6333.1
5870
6268

ASSEMBLY

6269

A-36
A-36
A-36
350W
SWEET

3143
1219
381
6320
204

DRAWN BY:

6234

DATE:

DF 6/21/2011

CHECKED BY:

DATE:

MFG BY:

DATE:

DF 6/21/2011

TITLE:

750SW-FB
STATUS:

PT #
6621

GRADE

WORK ORDER #: PART #:

DAY:

PRINT:

NOTE

NOTES:
- MANWAY DOES NOT HAVE GASKET
- MANWAY DOOR BOLTED WITH 4-6 BOLTS ONLY (REMAINDER TO SHIP LOOSE)
- CLIENT WILL SUPPLY WELD-ON GAUGE BOARD CLIPS TO BE INSTALLED BY
OUTLAW WELDING
- INSTALL TYPICAL FITTINGS AND CLIPS FOR FLOAT GUIDES
- INSTALL GUIDE CABLES AND FLOAT
- INSTALL TYPICAL CENTER LEVEL INDICATOR FITTING BUT INCREASE HOLE
SIZE TO 1 1/16" AND INSTALL REDUCER BUSHING TO 3/4"
- DO NOT INSTALL GAUGE HEAD, GAUGE BOARD OR PULLEY SYSTEM

B - 0 - 0"[0]
SHELL SEAM 1st AND 3rd COURSES

21

5'-6"
[1676]

NOTE

PARTS LIST

C - 67.5 - 106 1/4" [2699]

7'-4 1/2"
[2247]

CLIENT ID #

BOTTOM OF CAGE

A - 70.95 - 111 11/16"[2837]

D - 0 - 0"[0] 10
SHELL SEAM 2nd COURSE

12'-2 3/8"
[3718]

SER #

1. TANKS 721 TO 729 WERE BUILT AS PER REVISION 9


SEE 721 to 762 - RARE750SW-FB-6234 (TK-102-12302 to TK-102-12343)Rev.9
2. TANKS 730 TO 737 WERE BUILT AS PER REVISION 10
SEE 721 to 762 - RARE750SW-FB-6234 (TK-102-12302 to TK-102-12343)Rev.10
3. NO TANKS WERE BUILT TO REVISION 11
4. NO TANKS WERE BUILT TO REVISION 12

A - 50 - 78 11/16" [1999]

N4

20'-6"
N12 15
[6248]

BOTTOM OF SUPPORT

PROJECTION WELD DETAIL


VIII,X
3" EXT. / 1" INT.
VII,X
6" EXT. / 1" INT.
VII,X
6" EXT.
VII,X
5 1/2" EXT.
VI,VII,X
6" EXT.
VII,X
5 1/2" EXT.
VI,VII,X
5" EXT.
D
VII,X
5 1/2" EXT.
VII,X
5 1/2" EXT.
VII,X
5 1/2" EXT.
VII,X
5 1/2" EXT.

ELEVATION
ON ROOF
ON ROOF
0'-4 1/2" [114]
0'-5" [127]
3'-0" [914]
23'-0" [7010]
3'-0" [914]
3'-0" [914]
3'-0" [914]
20'-6" [6248]
20'-6" [6248]

REV:

13

MM 6/21/2011

APPROVED BY:

DATE:

SCALE:

SHEET:

MM 6/21/2011

VARIES

1 OF 2

ALL INFORMATION CONTAINED IN OR DISCLOSED BY THIS DOCUMENT IS CONSIDERED CONFIDENTIAL &


PROPRIETARY EXCEPT FOR RIGHTS EXPRESSLY GRANTED. ALL DESIGN, MANUFACTURE, USE, REPRODUCTION
AND SALES RIGHTS ARE RESERVED TO OUTLAW WELDING & MECHANICAL SERVICES LTD. 2006 COPYRIGHT

ORIENTATION IS MEASURED
CLOCKWISE FROM THE
INDICATED POSITION.
A

QUAD.
D

QUAD.
A

QUAD.
C

QUAD.
B

17'-1 3/8"
[5217]

27'-9 1/8"
[8461]

16'- 13/16"

26'- 1/4"
[7931]

C
ARC LENGTH MEASURED
ALONG OUTSIDE OF SHELL

QUADRANT - ANGLE - ARC LENGTH


eg. C - 65 - 105 11/16" [2685]

24

TH

C1

C1

N3

28

12

12

13

N4

C1

C1

N4

14

12

12

14

LADDER MAY
BE REMOVED

26

TH

28

N8

17

15'-5 3/16"
[4703]

15'-10 7/8"
[4848]

25
N13 18

15 N12

26

26

CLIENT ID NUMBERS ADDED TO DATA PLATES

SHIPPING DIMENSIONS
SCALE 1/50

26
25
2

25

A
C

187 23/32"
17 7/8"

26

17 7/8"

17 7/8"
17 7/8"

17 7/8"
19 N10

17 7/8"
17 7/8"
31 9/32"

31 9/32"

0'-6" TYP.
[152]

N11 20
1
1
27

26

11

N6

M1

4
6

187 23/32"

VIEW AT B-45
SCALE 1/50

VIEW AT A-45
SCALE 1/50

0'-3"
[76]

16

25

17 7/8"

17 7/8"

6" TYP. WIDTH

M1 11

45 TYP.

38 7/8"
2

MANWAY
3'- 1/2"
[927]

6
6

5
1

B
1
2'-6"
[762]

17

N8

77 3/4" TYP.

6
18 N13
5

9 19/32"

0'-11 3/4"
[298]

N12 15
STRUCTURAL STEEL NOTES:
1. SKID FRAMING TO BE OF SOLID WELDED CONSTRUCTION, 6mm
CONTINUOUS FILLET WELDS.
COPE ALL FRAMING MEMBERS INTO ONE ANOTHER. ALL WELDS TO BE
GROUND FLUSH ON BOTTOM OF SKID.
2. FABRICATOR SHALL BE RESPONSIBLE FOR ACCURATE PLACEMENT OF
MEMBERS FOR SUPPORT AND INSTALLATION OF EQUIPMENT.
3. COMMERCIAL BLAST TO SSPC-SP-6.
4. PRIMER SAME AS TANK
5. PAINT SAME AS TANK
6. ALL STEEL AND FABRICATION/ERECTION SHALL CONFORM TO:
-CSA STANDARD S16-09 LIMIT STATES DESIGN OF STEEL STRUCTURES
7. MATERIALS SHALL CONFORM TO THE FOLLOWING GRADES OF CSA G40.21:
-HOLLOW STRUCTURAL SECTIONS - 350W
-PLATE AND ROLLED SECTIONS - 300W
-ALL OTHER SECTIONS - 300W
8. SKID IS DESIGNED TO SUPPORT THE TOTAL TANK LOAD FOR LIQUIDS UP
TO A SPECIFIC GRAVITY OF 1.0.
9. TANK DESIGN IS INDEPENDENT OF SKID DESIGN AND THE TANK FLOOR
SHALL BE DESIGNED TO SUIT THE SKID ARRANGEMENT PER API
STANDARD 650, APPENDIX I.

SECTION A-A
MANWAY CENTERLINE
SCALE 1 / 12

N10 19

22

C2

N9

10

23

21

N7

N5

16

20

N6

N11

RECOMMENDED MINMUM SUPPORT POINTS (TYP. X 12)


FOUNDATION BY OTHERS.

27

PARTS LIST

ITEM QTY
DESCRIPTION
1
8 STEEL, W6x15 - 77 3/4 - 67 1/2 ENDS
2
6 STEEL, W6x15 COPED 2 ENDS - 28
3
8 STEEL, W6x15 COPED 2 ENDS - 54.875
4
8 STEEL, W6x15 COPED 2 ENDS - 71.25
5
4 STEEL, W6x15 COPED 2 ENDS - SPEC A
6
4 STEEL, W6x15 COPED 2 ENDS - SPEC B
7
2 STEEL, W6x15 COPED 2 ENDS - SPEC C

GRADE
350W
350W
350W
350W
350W
350W
350W

PT #
6323
6330
6335
6336
6327
6328
6329

C2

VIEW AT C-45
SCALE 1/50

VIEW AT D-45
SCALE 1/50

SER #

CLIENT ID #

721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741

TK-102-12302
TK-102-12303
TK-102-12304
TK-102-12305
TK-102-12306
TK-102-12307
TK-102-12308
TK-102-12309
TK-102-12310
TK-102-12311
TK-102-12312
TK-102-12313
TK-102-12314
TK-102-12315
TK-102-12316
TK-102-12317
TK-102-12318
TK-102-12319
TK-102-12320
TK-102-12321
TK-102-12322

1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2

742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762

TK-102-12323
TK-102-12324
TK-102-12325
TK-102-12326
TK-102-12327
TK-102-12328
TK-102-12329
TK-102-12330
TK-102-12331
TK-102-12332
TK-102-12333
TK-102-12334
TK-102-12335
TK-102-12336
TK-102-12337
TK-102-12338
TK-102-12339
TK-102-12340
TK-102-12341
TK-102-12342
TK-102-12343

ITEM QTY
DESCRIPTION
1
1 CPLG, HALF THD - CLASS 3000 1 1_2
ANGLED C/W REDUCER BUSHING 3_4
2
1 CPLG, HALF THD - CLASS 3000 2 C/W PLUG
3
1 CPLG, HALF THD - CLASS 3000 3_4 CW
PLUG
4
1 DATA PLATE WITH BRACKET
5
2 FLOOR HALF - STEEL, SHEET 1/4" - DIA
182.5[4636]
6
5 GAUGE BOARD BRACKET (SUPPLIED BY
OTHERS)
7
1 GUARD RAIL ASSY W .25 AC CABLE 750
STD
1 LADDER, OH&S COMPLIANT (PIP
8
STF05501)
9
4 LUG, LIFTING 6 X 12 X 3_8
10
1 LUG, TAIL ASSY
11
1 MANWAY-24 X 36 CW HINGED DOOR
12
1 MECHANICAL LEVEL GAGE ASSY 24FT R90
SW FLOAT GUIDE
1 NOZZLE, 10IN SHOP 4.25 TL W SHOP
13
FLANGE, GOOSENECK, BIRDSCREEN
14
1 NOZZLE, 2IN RFSO 7.25 IN TL
15
1 NOZZLE, 3IN RFSO 6IN TL
16
1 NOZZLE, 3IN RFSO 6IN TL C/W BLIND
17
1 NOZZLE, 3IN RFSO 6IN TL CW HUB BLIND
TAPPED 2IN
1 NOZZLE, 3IN RFSO 6IN TL CW HUB BLIND
18
TAPPED 2IN
19
1 NOZZLE, 3IN RFSO 6IN TL W REPAD 6332
20
1 NOZZLE, 3IN RFSO 6IN TL W REPAD 6332
1 NOZZLE, 4IN RFSO 6.5 IN TL
21
1 NOZZLE, 4IN W 2 RFSO 10 TL CW BLIND &
22
DOWNCOMER 33
23
1 NOZZLE, 4IN W 2 RFSO 12IN TL CW
DOWNCOMER 33
24
1 ROOF - STEEL, SHEET 3/16 DIA 180
25
3 SHELL-STEEL SHEET 3/16" - 96 - DIA 180
4 SHIPPING PAD ASSY
26
1 SKID, 750 - DIA 15 - W6x15
27
28
1 THIEF HATCH, WENCO TH8 (8 oz P - 0.4
oz V) SW

DRAWINGS MUST BE SIGNED AND APPROVED BEFORE


OUTLAW WELDING WILL BEGIN CONSTRUCTION

PROJECT:

APPROVED FOR CONSTRUCTION

RARE

ISSUE FOR CONSTRUCTION AS NOTED


REVISE AND RESUBMIT FOR APPROVAL
SIGN:

MONTH:
YEAR:

ANY CHANGES MADE AFTER APPROVAL MAY RESULT IN SIGNIFICANT


DELAYS AND/OR ADDITIONAL COSTS TO THE PROJECT

OILFIELD SERVICES CORP.

DWG SET:

PT #
6621

A-105N
A-105N

770
4274

A-36
A-36

694
1036
N/A

ASSEMBLY

4961

A-36

6240

A-36
A-36
A-36
SWEET

5831
250
727
6056

ASSEMBLY

6334

ASSEMBLY
ASSEMBLY
ASSEMBLY
ASSEMBLY

6223.1
2039.2
2386
6231

ASSEMBLY

6231.1

ASSEMBLY
ASSEMBLY
ASSEMBLY
ASSEMBLY

6333
6333.1
5870
6268

ASSEMBLY

6269

A-36
A-36
A-36
350W
SWEET

3143
1219
381
6320
204

DRAWN BY:

6234

DATE:

DF 6/21/2011

CHECKED BY:

DATE:

MFG BY:

DATE:

DF 6/21/2011

TITLE:

750SW-FB
STATUS:

GRADE

WORK ORDER #: PART #:

DAY:

PRINT:

NOTE

PARTS LIST

17 7/8"

NOTE

4
17 7/8"

CLIENT ID #

1. TANKS 721 TO 729 WERE BUILT AS PER REVISION 9


SEE 721 to 762 - RARE750SW-FB-6234 (TK-102-12302 to TK-102-12343)Rev.9
2. TANKS 730 TO 737 WERE BUILT AS PER REVISION 10
SEE 721 to 762 - RARE750SW-FB-6234 (TK-102-12302 to TK-102-12343)Rev.10
3. NO TANKS WERE BUILT TO REVISION 11

38 7/8"
0'-3"
[76]

SER #

REV:

13

MM 6/21/2011

APPROVED BY:

DATE:

SCALE:

SHEET:

MM 6/21/2011

1 / 40 2 OF 2

ALL INFORMATION CONTAINED IN OR DISCLOSED BY THIS DOCUMENT IS CONSIDERED CONFIDENTIAL &


PROPRIETARY EXCEPT FOR RIGHTS EXPRESSLY GRANTED. ALL DESIGN, MANUFACTURE, USE, REPRODUCTION
AND SALES RIGHTS ARE RESERVED TO OUTLAW WELDING & MECHANICAL SERVICES LTD. 2006 COPYRIGHT

Você também pode gostar