Escolar Documentos
Profissional Documentos
Cultura Documentos
DOC. NO.
PROJECT:
OWNER
2327-DC-001
RETI-MARU NATURAL GAS PIPELINE DIA. 10"
ENGRO FERTILIZERS LTD.
PREP. BY
REV.
SHOAIB
0
DATE
2/8/2013
INPUT DATA :
PIPELINE DESIGN CODE (ASME B )
PIPE O.D
PIPE WALL THICKNESS.
MAX. OPERATING TEMPERATURE
TIE-IN TEMPERATURE
MAX. OPERATING PRESSURE
MODULUS OF ELASTICITY
COEFFICIENT OF EXPANSION
FRICTION FACTOR B/W PIPE & SOIL
SOIL DENSITY
DEPTH OF BURIAL
SP.GRAVITY OF FLUID.
WEIGHT OF PIPE
CORROSION ALL0WANCE
CONCRETE DENSITY
FRICTION FACTOR B/W CONCRETE & SOIL
ANGLE OF INTERNAL FRICTION OF SOIL
CALCULATION :
CROSS-SEC. AREA
WT. OF PIPE + CONTENTS
HOOP STRESS
FRICTION FORCE
EXPANSION FORCE
LENGTH OF PIPE FROM POINT OF BURIAL
TO POINT OF NO MOVEMENT (CALC.)
TOTAL MOVEMENT OF PIPELINE AT
ABOVE GROUND END
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
=
31.8
10.75
in.
0.219
in.
167 Deg. F
77 Deg. F
715
Psig
29000000
Psi
6.50E-006 in./in./ F
0.3 (SILT=.3,SAND=.4,GRAVEL=.5)
90 lb/ft3
1442.308
3.28
ft
0.788
24.647
lb/ft
0.059
in.
150 lb/ft3
2403.846
0.5
25
Deg.
=
=
=
=
=
7
38
24020
170
157725
in^2
lb/ft
Psi
lbs/ft
lbs
928
ft
4.178
in.
282.797
20
ft
0.090
in.
6.098
AnchorBlockCalc
2327-DC-001
RETI-MARU NATURAL GAS PIPELINE DIA. 10"
ENGRO FERTILIZERS LTD.
PREP. BY
REV.
SHOAIB
0
DATE
2/8/2013
ANCHOR FORCE ,
Fac
154324
lbs
AnchorBlockCalc
2327-DC-001
RETI-MARU NATURAL GAS PIPELINE DIA. 10"
ENGRO FERTILIZERS LTD.
PREP. BY
REV.
SHOAIB
0
DATE
2/8/2013
X-SECTION BE
LENGTH
WIDTH
HEIGHT OF ANCHOR BLOCK
HEIGHT OF SOIL ABOVE ANCHOR
=
=
=
=
1.6
2
2.4
0.1
=
=
=
=
=
=
=
0.32
1017
17
40193
44313
2151
111055
156385
lbs
m
m
m
m
m3
lbs
m3
lbs
lbs
lbs/ft2
lbs
ALONG PIPE
ACROSS PIPE
(DEAD WEIGHT)
(Fac= 154324
OK
AnchorBlockCalc
3,SAND=.4,GRAVEL=.5)
Kg/m3
Kg/m3
m <====
<=====
EN POINT OF NO
AnchorBlockCalc
AnchorBlockCalc
ACROSS PIPE
(DEAD WEIGHT)
lbs)
AnchorBlockCalc