V VEBA

Ulazni podaci:
- l = 4,20m,
- q = 27,50kN/m,
- P1 = 55,00kN
- MB 40,
- Armatura RA 400/500
Proraun preseka
Pretpostavljene dimenzije: dmin = lo/20 = 420/20 = 21cm dmin = 25cm
b = d/2 = 25/2 = 12,5cm
b = 12,5cm

R = (P1 + ql)/2 = (55,0 + 27,5x4,20)/2 = (55,00 + 115,50)/2 = 85,25kN


TA = 85,25kN
T1,levo = 85,25 - 27,50x2,10 = 85,25 - 57,75 = 27,50kN
T1,desno = 27,50 - 55,0 = -27,50kN
TB = -27,50 - 27,50x2,10 = - 27,50 - 57,75 = - 85,25kN
M1 = Mmax = 27,504,202/8 + 55,04,20/4 = 60,64 + 57,75 = 118,39kNm
Mu = 1,8x118,39 = 213,10kNm

Mu,mer = (2/3)213,10 = 142,07kNm


a/b = 5,0/3,5 k = 1,903, b = 0,829
h 3 2 0,91

k2 2
M u ,mer 3 1,82 1,903 2 0,142 / 25,5 0,332m
fb 3

d = 33,2 + 6,0 =

39,2cm
Usvojeno: d = 40cm, b = 20cm, h = 34cm
M b (h / k ) 2 b f b (0,34 / 1,903) 2 0,20 25,5 0,1628MNm

M = 0,2131 - 0,1628 = 0,0503MNm


Potrebna zategnuta armatura
Aa

Mb
M
0,1628
0,0503

0,00144 0,00045

vi b h vi (h a ) 400 0,829 0,34 400 (0,34 0,06)

Aa 0,00189m 2 18,9cm 2
Usvojena zategnuta armatura 9R16 (18,1cm2)

Aa' = 4,5cm2
Usvojena pritisnuta armatura 3R16 (6,03cm2)
Kontrola napona
TA,u = 1,8x85,25 = 153,45kN
T1,u = 1,8x27,50 = 49,50kN
u,A= TA,,u/(bz) = 0,153/(0,20,90,34) = 2,50MPa > r = 1,3MPa
u,1= T1,u/(bz) = 0,049/(0,20,90,34) = 0,80MPa r = 1,3MPa
Mesto gde je r = 1,3MPa:
(2,50 -1,30)/ = (2,50 - 0,80)/2,10 = 1,48m
Deo napona koji se poverava betonu:
bu,A = 0,5(3r - u,A) = 0,5(3,90 - 2,50) = 0,70MPa
Preostali deo napona poverie se uzengijama:
Ru,A = uz,A = u,A - bu,A = 2,50 - 0,70 = 1,80MPa
Za R8, aa = 0,5cm2 tuz = m aavi/(uzb) = 20,510-4400/(1,800,2) = 0,111m

Usvajaju se dvosene uzengije UR8/10cm na duini od 1,50m od oslonaca.


Uzengije na srednjem delu nosaa su takoe UR8, ali na razmaku 25cm (tuz = 2d/3 =
80/3 = 26,7cm)

VI VEBA (261 - broj indeksa)


Ulazni podaci:
- A = 4,50m,
- B = 5,00m
- H = 3,25m
- H1 = 1,5H = 4,875m
- N=3
- g = 5,0kN/m2
- p = 2,5kN/m2
- q = 7,5kN/m2
- Df = 1,1m
- z,doz = 0,19MPa
- Beton MB 30
- Armatura RA 400/500

1. Analiza optereenja za stub P3

Od Pos 400+, 300+, 200+


- tavanica:
qxAxB = 7,5x4,5x5,0 = 168,75kN
- podvlake (d = 550/14 40cm) bd(A + B)AB = 0,4x0,4x(4,5 + 5,0)x25 = 38,00kN
- stub:
a2(H - d) AB = 0,42x(3,25 - 0,40)x25 = 11,40kN
P1 = 218,15kN
3P1 = 654,45kN
Od Pos 100+
- tavanica:
qxAxB = 7,5x4,5x5,0 = 168,75kN
- podvlaka (d = 550/14 40cm) bd(A + B)AB = 0,4x0,4x(4,5 + 5,0)x25 = 38,00kN
- stub:
a2(H1 - d) AB = 0,42x(4,875 - 0,40)x25 = 17,90kN
P4,1 = 224,65kN
- gornje etae:
3P1 = 654,45kN
Ukupno optereenje P4 = 879,10kN
2. Dimenzionisanje temelja samca ispod stuba P3
Priblino odreivanje povrine stope:
At

1,25 P4 1,25 0,879

5,78m 2 A
z ,dozv
0,19
P4,u
2 2a r

At 2,40m

Odreivanje visine stope:

0,879 1,8
0,90m
4 0,4 1,1

Kontrola stvarnog napona u tlu:

- vertikalna sila u stubu


879,10kN
- sopstvena teina stope:
2,4x2,4x0,9x25 = 129,60kN
- zemlja iznad stope: (2,4x2,4 - 0,4x0,4)x0,20x18 = 3,32kN
Ukupno optereenje V = 1012,02kN
z,stv = 1012,02/2,402 = 175,7kN/m2 = 0,176MPa < z,doz = 0,19MPa

Odreivanje armature:
q = P4/At = 879,10/2,402 = 152,60kN/m2
M = q1,02/2 = 152,60/2 = 76,3kNm/m
Mu = 1,8x76,3 = 137,34kNm
k

h
Mu
bxf b

0,84
0,137
1,0 x 20,5

0,84
10,282
0,0817

Iz tablica su dilatacije: b/a = 0,5/10,0 (za k = 9,651 10,282), pa se usvaja


b = 0,9838.
Aa , pot

Mu
0,137

0,000414m 2 / m 4,14cm 2 / m
vi b h 400 0,9838 0,84

Usvaja se u oba pravca armatura R12/20cm (5,66cm2/m)