PRESENTASI
PENGADAAN SISTEM
METER GAS ORIFIS
12 ANSI 150#
Daftar Isi
Latar Belakang dan Tujuan
Peta Lokasi Stasiun Pengukur
Struktur Organisasi Proyek
Engineering Process Design
Procurement Material & Jasa
Project Schedule
Metering Design and Specification
Standard & Codes
Data Proses
Main Line Sizing
Elemen Primer-Orifice Fitting
Elemen Sekunder-Transmitter
Elemen Final-Flow Computer
Elemen Final-Backup
Gas Chromatograph
Orifice Plate Calculation
Flowcomp Calculation Method
Thermowell Calculation
Drawing (P&ID, GA, dan SA)
Metering Station Block Diagram
Inspection and Test Plan (ITP)
Conclusion
LATAR BELAKANG
PEMBANGUNAN SISTEM
ALAT UKUR METER GAS
ORIFIS YANG AKAN
DIGUNAKAN SEBAGAI
ALAT UKUR SERAH
TERIMA GAS BUMI
ANTARA PT BINA
BANGUN WIBAWA MUKTI
DENGAN PT MARUTA
BUMI PRIMA
SISTEM METER GAS
ORIFIS MILIK DAN
DIOPERASIKAN OLEH
PT BINA BANGUN
WIBAWA MUKTI (PT
BBWM)
MAKSUD
DAN TUJUAN :
RENCANA
PELAKSANAAN
KEGIATAN
PEMBANGUNAN
SISTEM ALAT UKUR YANG
MEMENUHI
KETENTUAN
KETELITIAN
(AKURASI,
REPEATABILITY
AND
PERFORMANCE)
SESUAI
STANDARD ENGINEERING.
MEMENUHI
KETENTUAN
PERATURAN PERUNDANGAN
REPUBLIK
INDONESIA
UNTUK
MENDAPATKAN
PERSETUJUAN SISTEM ALAT
UKUR DAN OPERASI SERAH
TERIMA GAS BUMI PADA
KEGIATAN USAHA MIGAS.
PROJECT MANAGER
BOARD DIRECTOR
PROJECT
PLANNER
DOCUMEN
T CONTROL
QUALITY
CONTROL
SAFETY
PURCHASIN
G
CHIEF
ENGINEER
02
CHIEF
ENGINEER
01
INSTRUME
NT DIV.
MECHANIC
AL DIV.
FINNANCE
ELECTRICA
L DIV.
INSTRUME
NT DIV.
MECHANIC
AL DIV.
IT DIV.
SECURITY
Continous
Improveme
nt
Evaluate the
Process
Develop
Vision &
Objectives
Understand
Process
Engineerin
g Process
Design
Make
Process
Operational
Identify
Design
Process
Identify
Change
Levers
Implement
the Process
Requisition
Engineering
Inquiry
to PO
Vendor
Print
Manufacture &
Test
Support
From
Engineering
& QC
Pack and
Delivered
Project Schedule
DATA PROSES
Description
Base Pressure
Base Temperature
Design Press
Temp Design
Minimum Flowrate
Normal Flowrate
Maximum Flowrate
Minimum Pressure
Normal Pressure
Maximum Presure
Minimum Temperature
Normal Temperature
Maximum Temperature
Nominal
14.73
60
100
150
12" ANSI
150#
40
Unit
Psia
Deg F
Psig
Deg F
11.938
Inch
0.406
Inch
5
10
15
20
30
35
80
90
100
MMSCFD
MMSCFD
MMSCFD
Psig
Psig
Psig
Deg F
Deg F
Deg F
Operating
Conditions
No
Route
P
(Psig
)
Phas Flow
e
Rate
T (oF)
Minimum
30
80
Maximum
35
100
5
MMSCF
D
15
MMSCF
D
Line
Size
Vel.
Noise
Press
ure
Drop
(In)
(Fps)
dBA
Psi/10
0 ft
12
32.585
42.62
0.017
12
59.778
60.60
0.110
REFERENCES :
API Recommended Practice 14 E, Recommended
Practice for Design and Installation of Offshore
Production Platform Piping Systems, 5th edition,
1991.
INSTRUMENTION SPECIFICATIONS
ELEMEN PRIMER
Brand: CANALTA
Type Senior
Dual Chamber
12 inch, ANSI 150
AGA 3 Compliance with
17D
ORIFICE
FITTING
+ 5D Meter Runs
INSTRUMENTION SPECIFICATIONS
ELEMEN SEKUNDER
TRANSMITTER
STREAM
DIFF. PRESSURE ("HO)
TEMPERATURE (F)
Brand
Rosemount
Rosemount
Rosemount
Model/ type
3051 CD Series
3051CG Series
3144P
Range
(- 250 ~ 250)H2O
(- 58 up ~ 752) F
Calibration Range
(0 ~ 200)H2O
(0 ~ 100) Psig
(0 ~ 200) F
DIFF. PRESS
TRANSMITTER
PRESSURE
TRANSMITTER
TEMPERATURE
TRANSMITTER
INSTRUMENTION SPECIFICATIONS
FLOBOSS S 600
Manufacture
EMERSON
CPU
32-Bit
Historical Data
Up to 35 Days
Save
Customize
3 Serial (RS232/RS485)
Port Comm
1x Ethernet
Akurasi
+- 0.025%
FLOW COMPUTER
FLOBOSS S 600
FlowRate &
Energy
Calculation
Embedded Comply:
AGA-3
GPA 2172 - 96
AGA-8
INSTRUMENTION SPECIFICATIONS
Three Pens
DP Range
(0 ~ 200) H2O
Static Press.
Range
Temperature
Range
Accuracy
(0 ~ 100) Psig
(0 ~ 200) Deg F
0.5% FS.
INSTRUMENTION SPECIFICATIONS
GAS
CROMATOGRAPH
Manufacture
Calculation
:
:
:
:
ABB
GPA 2172-96 (Z by AGA 8 or ISO 6976-95; ISO
12213 (by AGA8); in the future ASTM D 3588
GOST or ISO mass
Air (Contains N2, Ar, CO and O2 but not CO2),
C1 CO2 C2 C3 IC4 NC4 C1 CO2 C2 C3 IC4
NC4
NEMA/Type 4X/IP 56, aluminum alloy with
Helium (consumption rate typically <20
cc/
minute during analysis cycle)
Analysis time
Repeatability
:
:
Determined by application
0.025% @ ambient
0.05% over temperature
Temp. range
(storage)
Temp. range
(normal)
ABB 8200 SERIES
Communication
port
Supply voltage
DESCRIPTION
Minimum
Normal
Design
Design
Orifice Plate Orifice Plate
MGO-1473
A/B
MGO-1473
A/B
Maximum
Design
Orifice
Plate
UNIT
MGO-1473
A/B
THERMOWELL CALCULATION
P & ID
Drawing
GENERAL ARRANGEMENT
Drawing
SYSTEM ARCHITECHTURE
Drawing
FLOWCOMP
SUPERVISORY COMPUTER
CCR
PRINTER
FIELD
STREAM A & B
CONCLUSION
RANCANG BANGUN SISTEM METER GAS ORIFIS MENGACU PADA
DATA PROSES DARI BADAN USAHA (BU) YANG MENCAKUP
(PRESSURE, DIFF. PRESSURE, TEMPERATURE, FLOW RATE MINIMUM
~ MAKSIMUM SERTA KOMPOSISI GAS) TELAH DILAKSANAKAN
SESUAI KETENTUAN PERATURAN, KAIDAH KETEKNIKAN YANG BAIK
UNTUK KESELAMATAN KESEHATAN KERJA DAN LINDUNGAN
LINGKUNGAN SERTA PROSEDUR YANG BERLAKU. DINYATAKAN
DAPAT MEMENUHI SYARAT MUTU, SPESIFIKASI TEKNIS UNTUK
KEHANDALAN UNJUK KERJA SEBAGAIMANA YANG DIHARAPKAN.
PERAKIT PEREKAYASA