REV. NO
GRID
S.No.
CHECKLIST NO.
AS ON SITE
DESCRIPTION
P.C.C. SIZE
P.C.C. THICKNESS
GRADE OF CONCRETE
CASTING DATE
ANTRITERMITE TREATEMENT
RMC FROM
AS PER DRAWING
REMARKS
SPECIAL NOTES
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
S.No.
CHECKLIST NO.
AS ON SITE
DESCRIPTION
GRADE OF CONCRETE
FOOTING SIZE L X B X H
REINFORCEMENT DETAIL
BOTTOM COVER
SIDE COVER
10
SHUTTERING
11
12
COLUMN REINFORCEMENT
13
CASTING DATE
14
RMC FROM
AS PER DRAWING
REMARKS
SPECIAL NOTES
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
S.No.
DESCRIPTION
GRADE OF CONCRETE
COLUMN NUMBER
COLUMN SIZE
REINFORCEMENT
SIDE COVER
SHUTTERING
CASTING DATE
10
RMC FROM
11
12
13
SPECIAL NOTES
CHECKLIST NO.
AS PER DRAWING
AS ON SITE
REMARKS
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
S.No.
DESCRIPTION
GRADE OF CONCRETE
THICKNESS OF RAFT
REINFORCEMENT DETAILS
BOTTOM COVER
SIDE COVER
SHUTTERING
CASTING DATE
10
RMC FROM
11
SPECIAL NOTES
CHECKLIST NO.
AS PER DRAWING
AS ON SITE
REMARKS
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
REV. NO
GRID
BUILDING NO.
CHECKLIST NO.
DESCRIPTION
Is staging design ok? Is spacing of props for slabs and beams
adequate
check alignment, level and rigidity of staging. Variation in level of
formwork should be within 3mm in 5 M span
Check all props and their supporting base. Are end of props cut
square at both ends and resting on firm support
Are braces provided to props of studs adequately
Removal of props and replacing is done as per consultants
instruction
Formwork material used is new or old? If old are the repairs done
satisfactorily
is the Formwork leak proof and gaps in the formwork are sealed
properly
Is formwork clean i.e. it is free from any chipping, dust, nails sawdust
etc.
Oil applied to shuttering material
Alignment and level of formwork is OK?
YES
NO
11
DESCRIPTION
1
2
3
4
5
6
7
GRADE OF CONCRETE
R.L. OF SLAB BOTTOM
R.L. OF SLAB TOP
THIKNESS OF SLAB
REINFORCEMENT DETAILS
BOTTOM COVER PROVIDED
ADEQUATE & APPROPRIATE CHAIRS ARE PROVIDED
CASTING DATE
10
RMC FROM
SPECIAL NOTES
As per
drawing
On Site
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
REMARKS
REMARKS
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
CHECKLIST NO.
S.No.
1
2
3
4
5
6
DESCRIPTION
YES
NO
REMARKS
PCC DATE :
FOR JLLM
QUALITY ENG
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
S.No.
1
DESCRIPTION
SIZE OF TRENCH
GEOTEXTILE MATERIAL WRAPPED ALL
AROUND PIT
DIAMETER OF PIPE
GRADIENT PROVIDED
7
8
SPECIAL NOTES
CHECKLIST NO.
AS PER DRAWING
AS ON SITE
REMARKS
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
CHECKLIST NO.
S.No.
DESCRIPTION
YES
OBSERVATIONS/REMARKS
FOR JLLM
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
S.No.
DESCRIPTION
GRADE OF CONCRETE
PLINTH BEAM NO
REINFORCEMENT
SIDE COVER
SHUTTERING
CASTING DATE
RMC FROM
10
11
CHECKLIST NO.
AS PER DRAWING
AS ON SITE
REMARKS
SPECIAL NOTES
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
REV. NO
GRID
S.No.
BUILDING NO.
DESCRIPTION
1
2
3
4
5
6
7
GRADE OF CONCRETE
R.L. OF SLAB BOTTOM
R.L. OF SLAB TOP
THIKNESS OF SLAB
REINFORCEMENT DETAILS
BOTTOM COVER PROVIDED
ADEQUATE & APPROPRIATE CHAIRS ARE PROVIDED
CASTING DATE
10
RMC FROM
SPECIAL NOTES
:
As per
drawing
CHECKLIST NO.
On Site
REMARKS
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
REV. NO
GRID
S.No.
BUILDING NO.
DESCRIPTION
2
3
4
Courses are truly horizontal with suitable bond pattern to break the vertical joints.
7
8
Suitable toothing or grooves or stepping are provided for continuation of masonry work.
CHECKLIST NO.
Yes
No
REMARKS
10
11
Are the joints raked at least to an average depth of 10 mm when mortar is green.
SPECIAL NOTES
FOR JLLM
QUALITY ENGINEER(JLLM)
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
CHECKLIST NO.
S.No.
DESCRIPTION
Observations
REMARKS
FOR JLLM
SITE INCHARGE(NCCL)
DATE
BUILDING NO.
REV. NO
GRID
CHECKLIST NO.
S.No.
DESCRIPTION
Observations
REMARKS
FOR JLLM
SITE INCHARGE(NCCL)