Você está na página 1de 1

Project: Nutroton S.A. Quotation No. 09128.1.0.

Kablitz & Mitthof / CME

11.02.2010
MN

Mass balance
Notes:

For the water-steam cycle please see attached document

Input and Output mass balance

Mass Flow
Fuel
Primary Air
Secondary / Tertiary Air
Condensate / Heating
Steam
Demineralized Water
Process Water
Sum

Unit
kg/h
kg/h
kg/h

Input Mass Flow


Part. Load Special Load
Full Load
Aver.
Max.
--Min.
14174
18708
24866
11183
6507
41112
48220
53448
28825
16773
33638
32146
35631
19216
11182

kg/h
kg/h
kg/h
kg/h

47023
50726
51063
2475
2670
2688
333
647
1773
138756 153116 169470

Exhaust Gases
Grate Ashes
Boiler Ashes
Flue Gas Cleaning Ashes
Live Steam
Effluents from blowdown tank
Sum

kg/h
kg/h
kg/h
kg/h
kg/h

87929
52
21
86
49850

112090
2741
34
138
53589

58667
438
17
67
32153

34223
256
10
39
18756

kg/h
kg/h

818
879
879
138756 153116 169470

879
92221

879
54162

30323
2288
387
92221

Min.

Output Mass Flow


Part. Load Special Load
Full Load
Aver.
Max.
---

17644
1831
225
54162
97779
730
28
112
53589

Full Load = Values are dependent from the fuel, at average and max. values incl. overshoot over 100% reference steam mass flow,
at average value with lower air ratio (lambda), at max. value with higher air ratio
Partial Load = permitted partial load concerning furnace/emission parameters and acid dew point, values only from the design fuel
Special Load = not permitted partial load concerning furnace/emission parameters and acid dew point, probably possible to operate
\\Sbserver08\Daten\Works\Vertrieb\Anfragen_Kunde\Almas Domingas\Auslegung\Massenbilanz-Allgemein-2006-04-08.xls