Set your IP address laptop to 169.254.1.2 with Gateway 169.254.1.1 and subnetmask 255.255.0.0 Open Element Manager Connect to 169.254.1.1
LOAD OAM_ACCESS SCRIPT
Go to Menu Tools and then select O&M Access Configuration Select the script OAM_Access and click NEXT Click NEXT until a popup windows ask you to confirm. Click OK Wait for the cript to run. RBS will disconnect, this is normal. DO NOT click the CLOSE ALL button When the CONTINUE button activates again, click it. Then click OK. Element Manager will close.
LOAD EXTERNAL HARDWARE SCRIPT
Go to Menu Tools and select Site Equipment Configuration Select the script External_HW and then click NEXT Click NEXT until a popup window ask you to confirm. Click OK Wait for the script to run. Click OK when it finish
RUN SITE COMPLETE SCRIPT
Go to Menu Tools and select Run Command File Select the script Site_Complete.mo
Click the RUN button. Check for the Succesfull message. Then close the window
GET FINGERPRINT AND SAVE CV
Go to view Licensing and copy the fingerprint Send the fingerprint to coordinator for request of license. Go to view Upgrade and Backup then go to tab CV Click button CREATE CV Write a name for the new CV, then click APPLY Click button SET STARTABLE Click button RELOAD WITH THIS CV select the proper reasons and the click EXECUTE Wait for the RBS to restart End of Procedure