Você está na página 1de 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN

GARDU INDUK 150 KV PLN P3B JAWA-BALI


6

10

11

12

13

14

15

10

11

12

13

14

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

DESIGNATION

1
1

1
1

1
1
1
1
1
1
1

15

BLOK

DISTRIBUTION TRANSF

INTERBUS TRANF

SUBSTATION

MNEMO

NO

PEMELIHARAAN

RTU

OPERASI
1

PROTOKOL KOMUNIKASI
1

HNZ

HNZ

IND

Indactic 33

3
4
5
6
7
8

DNP
101
103
104
61850
MDBUS

DNP 3
IEC 870-5-101
IEC 870-5-103
IEC 870-5-104
IEC 61850
MODBUS

1
1
1
1
1
1
1
8

1
1
1
1
1
1
1
8

TOTAL

TAP CHANGER ( TC )
1

TPI

TAP POSITION INDICATION

1
1

TOTAL

1
1

1
1

TELE MEASUREMENT ( TM )
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

HZ
KV
A
MW
MX
CCB
TEMP
PRES
P'o
P'r
AMF
KWH
KVARH
RH
CNTA
CTPI

FREQUENCY
KILOVOLT
AMPERE
MEGAWATT
MEGAVAR
COUNTER CIRCUIT BREAKER
TEMPERATURE
PRESSURE
REAL POWER SETTING
MAX POWER VARIATION SETTING
AMPERES FAULT ( PER PHASE )
KILOWATT HOUR
KILOVAR HOUR
RELATIVE HUMIDITY
COUNTER ARESTER
COUNTER TAP POSITION INDICATION
TOTAL

1
1
1

1
1
1
1

1
1
1
1

1
1
1
1

1
1
1

1
1
1

1
1
1
1
1

1
1
1
1
1
1
1

1
1
1

1
1
1

1
1
1

1
1
1

1
1
12

1
1
12

1
1
1

1
1

1
1
1
1
1

1
1
1

1
1
1
1

1
1
3
3

1
1
1
1

1
1
1

10

1
4

1 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI
7

10

11

12

13

14

15

10

11

12

13

14

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

1
2

1
2

1
2

1
2

2
4

1
2

1
2

1
2

3
6

1
2

1
2
1
1

1
2
1
1

3
6

1
2
1

1
2
1
1

1
2
1
1

BUS COUPLER

DESIGNATION

1
2
1

1
1

15

BLOK

CABLE FEEDER

OHL FEEDER

BUS SECTION

SUBSTATION

MNEMO

NO

PEMELIHARAAN

RTU

OPERASI
1

REMOTE CONTROL DIGITAL ( RCD )


1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

DCBC
CB
BI
LI
LR
LRT
TCC
TC
CSO
ES
RACK
TFAM
SAM
RMT
GUC
LFR
GOV
AVR
AQR
CD

DUMMY CIRCUIT BREAKER CLOSED/OPENED


CIRCUIT BREAKER CLOSED/OPENED
BUS ISOLATOR SWITCH CLOSED/OPENED
LINE ISOLATOR SWITCH CLOSED/OPENED
LOCAL REMOTE
LOCAL/REMOTE SWITCH FOR TAPCHANGER
TAP CHANGER AUTO/MANUAL
TAP CHANGER RAISE/LOWER
CHECK SYNCHRONIZING OVERRIDE
EARTH SWITCH CLOSED/OPENED
CIRCUIT BREAKER RACKIN/RACKOUT
TRANSFORMER FAN AUTO/MANUAL
SYNCHRONIZATION AUTO/MANUAL
RESET MASTER TRIP
GENERATOR UNIT RUN/STOP
LOAD FREQ REQUEST ON/OFF
FREE ACTING GOVERNOR ACTIVE
AUTOMATIC VOLTAGE REGULATOR ON/OFF
AUTOMATIC POWER FACTOR ACTIVE
CONTROL DISABLE SWITCH
TOTAL

1
1
2
1
1
1
1
1

2
4
1
1
1
1
1
1

1
1

1
1
1

1
1
1
1

1
1
1
3

1
1
1
3

1
2

1
1
1

1
3

15

10

18

1
2

1
2

2
4
1
1

1
2
1
1

1
2
1
1

1
2
1
1

1
2
1
1

3
6

1
2
1
1

REMOTE CONTROL ANALOG ( RCA )


1 Po
2 Pr
3N

REAL POWER SET POINT


MAX POWER VARIATION SET POINT
LOAD FREQ CONTROL N_LEVEL
TOTAL

TELESIGNAL DOUBLE ( TSD )


1
2
3
4
5

DCBC
CB
BI
LI
LR

DUMMY BREAKER CLOSED/OPENED


CIRCUIT BREAKER CLOSED/OPENED
BUS ISOLATOR SWITCH CLOSED/OPENED
LINE ISOLATOR SWITCH CLOSED/OPENED
LOCAL REMOTE

1
2

1
2

1
2
1
1

1
2
1
1

1
2
1

1
2
1
1

1
2

1
2

3
6

1
2

1
1

2 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI
9

10

11

12

13

14

15

10

11

12

13

14

15

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

3
8

DESIGNATION

LOCAL/REMOTE SWITCH FOR TAPCHANGER


TAP CHANGER AUTO/MANUAL
TAP CHANGER RAISE/LOWER
CHECK SYNCHRONIZING OVERRIDE
EARTH SWITCH CLOSED/OPENED
CIRCUIT BREAKER RACKIN/RACKOUT
TRANSFORMER FAN AUTO/MANUAL
SYNCHRONIZATION AUTO/MANUAL
RESET MASTER TRIP
GENERATOR UNIT RUN/STOP
LOAD FREQ REQUEST ON/OFF
FREE ACTING GOVERNOR ACTIVE
AUTOMATIC VOLTAGE REGULATOR ON/OFF
AUTOMATIC POWER FACTOR ACTIVE
CONTROL DISABLE SWITCH
LOAD FREQ CONTROL ON/OFF SWITCH
LOAD FREQ AVAILABLE/NOT AVAILABLE
POWER STATION OPERATED
TOTAL

1
1
1
1

1
1
1
1
1
1
1

1
1
1
1

1
1
1
8

1
1
1
7

1
1

1
1

1
1
1
1
1

1
1

BLOK

GENERATOR

INTERBUS TRANF

CABLE FEEDER

BUS COUPLER

LRT
TCC
TC
CSO
ES
RACK
TFAM
SAM
RMT
GUC
LFR
GOV
AVR
AQR
CD
LFC
LFA
PSO

BUSBAR

6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23

MNEMO

SUBSTATION

NO

PEMELIHARAAN

RTU

OPERASI
1

1
1

1
1
1
5

1
1
1
4

1
1
1
1
1
1

1
3

15

15

11

26

TELESIGNAL SINGLE (TSS)


1 VACF
2
3
4 VDCF
5
6
7
8
9
10
11
12
13
14

220F
380F
220RF
220SF
110RF
110SF
24RF
24SF
48RF
48SF
DCG
DCF

VAC FAILURE
220 VAC FAILURE
380 VAC FAILURE
VDC FAILURE
220VDC RECTIFIER FAILURE
220VDC SUPPLY FAILURE
110VDC RECTIFIER FAILURE
110VDC SUPPLY FAILURE
24VDC RECTIFIER FAILURE
24VDC SUPPLY FAILURE
48VDC RECTIFIER FAILURE
48VDC SUPPLY FAILURE
DC GROUND
DC SUPPLY FAILURE

1
1
1
1
1
1
1
1
1
1
1
1
1
1

3 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI

RSTA
DOOR
SIA
CSP
OCPA
PWF
RTN
SYNF
FPO

10

11

12

13

14

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

CAPACITOR

GENERATOR

DESIGNATION

PERIPHERAL ALARM
DISTURBANCE FAULT RECORDER FAULTY
EVENT RECORDER FAILURE
FAULT DATA CAPTURED
GENERATOR READY
OVER VOLTAGE RELAY
AIR CONDITIONING FAILURE
CIRCUIT BREAKER AUTO RECLOSE
AUTO RECLOSE ON/OFF
BAY FAULT DC
BREAKER FAULT
LOW PRESSURE ALARM
LOW PRESSURE BLOCK
LOW PRESSURE TRIP
POLE DISCREPANCY
CIRCUIT BREAKER DRIVE FAILURE
TRIP COIL 1 & 2 SUPERVISORY
CIRCUIT BREAKER MAINTENANCE
RTU ALARM
INTERNAL RTU
CABINET TEMPERATUR
COMMUNICATION FAULTY
CARRIER FAULTY
FO TERMINAL FAULTY
PLC TERMINAL FAULTY
RADIO LINK FAULTY
PABX FAULTY
RESET ALARM
DOOR ACTIVATED
STATION INTRUDER ALARM
CHECK SYNCHRONIZING IN PROGRESS
OIL CABLE PRESSURE ALARM
PILOT WIRE FAILURE
RELAY TEGANGAN NOL
SYNCHRONIZING FAILURE
FIRE PROTECTION OPERATED

1
1

1
1

1
1

1
1

1
1
1

1
1
1
1
1
1
1

1
1
1
1
1
1
1

1
1
1
1
1
1
1

1
1
1
1
1
1
1

1
1
1
1
1
1
1

1
1
1
1
1
1
1

1
1

1
1

1
1
1
1
1
1
1

1
1
1
1
1
1
1

3
3
3
3
3
3
3

1
1
1
1
1
1
1

15

BLOK

15

DISTRIBUTION TRANSF

14

INTERBUS TRANF

13

CABLE FEEDER

12

GEN TRANSF

CF
FOTF
PLCF
RADF
PBXF

11

DIAMETER

COM

10

REACTOR

IR
CTE

OHL FEEDER

CBM
RTUA

BUS SECTION

LPA
LPB
LPT
PD
CBDF
TC12

BUS COUPLER

AR
ARO
BF
BRF

BUS SECTION

DFRF
ERF
FDC
GRE
OVR
AIRCF

BUS COUPLER

PHA

BUSBAR

15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50

MNEMO

SUBSTATION

NO

PEMELIHARAAN

RTU

OPERASI
1

1
1
1
1

1
1

1
1

1
1
1
1

1
1

1
1

1
1

1
1

1
1

1
3

1
1

1
1
1
1
1
1
1
1
1
1
1
1
1

1
1
1

1
1

1
1
1
1
1

1
1
1

3
1

4 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI
1

10

11

12

13

14

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

DESIGNATION

TEMPERATURE ALARM
HV WINDING TEMPERATUR ALARM
LV WINDING TEMPERATUR ALARM
OIL TEMPERATURE ALARM
TEMPERATURE TRIP
HV WINDING TEMPERATUR TRIP
LV WINDING TEMPERATUR TRIP
OIL TEMPERATUR TRIP
TRANSFORMER ALARM
BUCHOLZ ALARM
SUDDEN PRESSURE ALARM
OIL LEVEL ALARM
OUT OF STEP ALARM
TRANSFORMER TRIP
BUCHOLZ TRIP
SUDDEN PRESSURE TRIP
FIRE DETECTION & PROTECTION
JANSEN TRIP
TRANFORMER AVR FAILURE
TAP CHANGER ALARM
TAP POSITION INDICATION FAILURE
TAP CHANGER HIGH LIMIT
TAP CHANGER LOW LIMIT
TRANSFORMER COOLING FAN FAILURE
TRANSFORMER COOLING PUMP FAILURE
REACTOR FAILURE
VOLTAGE STATUS
VOLTAGE TRANSFORMER FAILURE
FIRE ALARM
FIRE ALARM SYSTEM FAILURE
PROTECTION ON TEST
FREE ACTING GOVERNOR ON/OFF
AUTOMATIC VOLTAGE REGULATOR ON/OFF
AUTOMATIC POWER FACTOR ON/OFF
LOAD FREQ CONTROL UNIT FAILURE

1
1
1

1
1
1

1
1
1

1
1
1

1
1
1
1

1
1
1
1

1
1
1
1
1
1
1
1
1
1
1

1
1
1
1
1
1
1
1
1
1
1

15

BLOK

15

DISTRIBUTION TRANSF

14

INTERBUS TRANF

13

DIAMETER

TAF
TCA
TPIF
TCH
TCL
TCFF
TCPF
RF
VS
VTF
FR
FRSF
POT
GV
AV
AQ
LFF

12

REACTOR

BUC2
SPT
FDP
JANT

11

CAPACITOR

TRT

10

DISTRIBUTION TRANSF

BUCA
SPA
OLA
OOS

INTERBUS TRANF

TRA

CABLE FEEDER

WTHVT
WTLVT
OTT

OHL FEEDER

TET

BUS SECTION

WTHVA
WTLVA
OTA

BUS COUPLER

TEA

BUSBAR

51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85

SUBSTATION

MNEMO

NO

PEMELIHARAAN

RTU

OPERASI
1

1
1

1
1

1
1

1
1

1
1
1
1
1
1
1

5 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI

86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120

UT
GTT
LOWCT
PRDT
MTO
UFR
UVR
OVR
PF
OCRF
OVRF
UVRF
GFRF
DZAF
DZBF
DEFAF
DEFBF
CDAF
CDBF
TPAF
TPBF
DIFF
REFF
BPAF
BPBF
CCPF
RCBF
SZPF
TTR
DZARX
DZBRX
DEARX
DEBRX
DTARX
DTBRX

10

11

12

13

14

15

10

11

12

13

14

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

DESIGNATION

UNIT TRIP
GENERATOR TRANSFORMER TRIP
LOW OIL PRESSURE CABLE TRIP
PRESSURE RELAY DEVICE TRIP
MASTER TRIP OPERATE
UNDER FREQUENCY RELAY OPERATE
UNDER VOLTAGE RELAY OPERATE
OVER VOLTAGE RELAY OPERATE
PROTECTION FAULTY
OVER CURRENT RELAY FAILURE
OVER VOLTAGE RELAY FAILURE
UNDER VOLTAGE RELAY FAILURE
GROUND FAULT RELAY FAILURE
DISTANCE RELAY (a) FAILURE
DISTANCE RELAY (b) FAILURE
DIRECTIONAL EARTH FAULT (a) FAILURE
DIRECTIONAL EARTH FAULT (b) FAILURE
CURRENT DIFFERENTIAL RELAY (a) FAILURE
CURRENT DIFFERENTIAL RELAY (b) FAILURE
TELEPROTECTION (a) FAILURE
TELEPROTECTION (b) FAILURE
DIFFERENTIAL FAILURE
RESTRICTED EARTH FAULT FAILURE
BUSBAR PROTECTION (a) FAILURE
BUSBAR PROTECTION (b) FAILURE
CIRCULATING CURRENT PROTECTION FAILURE
RELAY CIRCUIT BREAKER FAIL FAILURE
SHORT ZONE PROTECTION FAILURE
TELEPROTECTION TRIP RECEIVE
DISTANCE (a) RELAY RECEIVE
DISTANCE (b) RELAY RECEIVE
DIRECTIONAL EARTH FAULT (a) RELAY RECEIVE
DIRECTIONAL EARTH FAULT (b) RELAY RECEIVE
DIRECT TRANSFER TRIP (a) RECEIVE
DIRECT TRANSFER TRIP (b) RECEIVE

15

BLOK

BUSBAR

MNEMO

SUBSTATION

NO

PEMELIHARAAN

RTU

OPERASI
1

1
1

1
1
1

1
1
1

1
1
1

1
1

1
1
1

1
1
1
1
1
1
1
1
1
1
1
1

1
1
1
1

1
1

1
1

1
1

1
1

1
1

1
1
1

1
1
1

1
1

1
1

1
1
1
1
1

1
1

1
1

1
1

1
1

1
1

3
3
3

1
1

1
1
1
1
1
1

1
1

6 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI

DZATX
DZBTX
DEATX
DEBTX
DTATX
DTBTX
P1BP
BPA
BPB
P1CD
CDAR
CDAS
CDAT
CDBR
CDBS
CDBT
P1DEF
DEFAR
DEFAS
DEFAT
DEFBR
DEFBS
DEFBT
P1DIF
P1REF
P1Z1
DZ1AR
DZ1AS
DZ1AT
DZ1BR
DZ1BS
DZ1BT
P1Z2
DZ2AR
DZ2AS
DZ2AT

10

11

12

13

14

15

10

11

12

13

14

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

DESIGNATION

TELEPROTECTION TRIP TRANSMIT


DISTANCE (a) RELAY TRANSMIT
DISTANCE (b) RELAY TRANSMIT
DIRECTIONAL EARTH FAULT (a) RELAY TRANSMIT
DIRECTIONAL EARTH FAULT (b) RELAY TRANSMIT
DIRECT TRANSFER TRIP (a) TRANSMIT
DIRECT TRANSFER TRIP (b) TRANSMIT
BUSBAR PROTECTION
BUSBAR PROTECTION (a)
BUSBAR PROTECTION (b)
CURRENT DEFFERENTIAL
CURRENT DIFFERENTIAL (a) PHASE R
CURRENT DIFFERENTIAL (a) PHASE S
CURRENT DIFFERENTIAL (a) PHASE T
CURRENT DIFFERENTIAL (b) PHASE R
CURRENT DIFFERENTIAL (b) PHASE S
CURRENT DIFFERENTIAL (b) PHASE T
DIRECTIONAL EARTH FAULT
DIRECTIONAL EARTH FAULT (a) PHASE R
DIRECTIONAL EARTH FAULT (a) PHASE S
DIRECTIONAL EARTH FAULT (a) PHASE T
DIRECTIONAL EARTH FAULT (b) PHASE R
DIRECTIONAL EARTH FAULT (b) PHASE S
DIRECTIONAL EARTH FAULT (b) PHASE T
DIFFERENTIAL
RESTRICTED EARTH FAULT
DISTANCE PROTECTION ZONE 1
DISTANCE (a) PHASE R ZONE 1
DISTANCE (a) PHASE S ZONE 1
DISTANCE (a) PHASE T ZONE 1
DISTANCE (b) PHASE R ZONE 1
DISTANCE (b) PHASE S ZONE 1
DISTANCE (b) PHASE T ZONE 1
DISTANCE PROTECTION ZONE 2
DISTANCE (a) PHASE R ZONE 2
DISTANCE (a) PHASE S ZONE 2
DISTANCE (a) PHASE T ZONE 2

1
1

1
1
1
1
1
1

15

BLOK

BUS COUPLER

TTT

BUSBAR

121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157

SUBSTATION

MNEMO

NO

PEMELIHARAAN

RTU

OPERASI
1

1
1

1
1
1
1

1
1
1
1
1
1
1

1
1
1
1
1
1

1
1
1
1
1
1
1
1
1

1
1

1
1

1
1

1
1
1
1
1
1
1
1
1
1
1

7 of 8

STANDARDISASI TELEINFORMASI PLAN FUNGSI OPERASI DAN PEMELIHARAAN


GARDU INDUK 150 KV PLN P3B JAWA-BALI

CCPA
CBFA
SZPA
CCPB
CBFB
SZPB
CBTR
PHR
PHS
PHT

12

13

14

15

10

11

12

13

14

OHL FEEDER

CABLE FEEDER

INTERBUS TRANF

DISTRIBUTION TRANSF

CAPACITOR

REACTOR

DIAMETER

GEN TRANSF

GENERATOR

BLOK

RTU

SUBSTATION

BUSBAR

BUS COUPLER

BUS SECTION

OHL FEEDER

DIAMETER

GEN TRANSF

GENERATOR

DESIGNATION

DISTANCE (b) PHASE R ZONE 2


DISTANCE (b) PHASE S ZONE 2
DISTANCE (b) PHASE T ZONE 2
DISTANCE PROTECTION ZONE 3
DISTANCE (a) PHASE R ZONE 3
DISTANCE (a) PHASE S ZONE 3
DISTANCE (a) PHASE T ZONE 3
DISTANCE (b) PHASE R ZONE 3
DISTANCE (b) PHASE S ZONE 3
DISTANCE (b) PHASE T ZONE 3
GROUND FAULT RELAY
OVER CURRENT RELAY
DIRECT TRANSFER TRIP
CIRCULATING CURRENT PROTECTION (a) OPERATE
CIRCUIT BREAKER FAILURE (a) OPERATE
SHORT ZONE PROTECTION (a) OPERATE
CIRCULATING CURRENT PROTECTION (b) OPERATE
CIRCUIT BREAKER FAILURE (b) OPERATE
SHORT ZONE PROTECTION (b) OPERATE
CB TRIP
TRIP PHASE R
TRIP PHASE S
TRIP PHASE T
TOTAL

1
1

1
1

1
1

1
1

1
1

15

BLOK

11

REACTOR

10

CAPACITOR

DISTRIBUTION TRANSF

P2GFR
P2OCR
P3DTT

INTERBUS TRANF

DZ3AR
DZ3AS
DZ3AT
DZ3BR
DZ3BS
DZ3BT

CABLE FEEDER

P1Z3

BUS SECTION

DZ2BR
DZ2BS
DZ2BT

BUS COUPLER

158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180

BUSBAR

MNEMO

SUBSTATION

NO

PEMELIHARAAN

RTU

OPERASI
1

1
1
1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
3
3
1
3
3

1
1
1

1
1
1

1
1
1

1
1
1

1
1
1

1
1
1

1
1
1

1
1
1

3
3
3

1
1
1

26

27

88

41

55

59

26

26

71

22

1
1

1
1

1
1
1
1
1
1
1
1

14

15

13

27

18

REVISI : 00
KETERANGAN :
-) UNTUK FUNGSI REMOTE, MCC DISESUAIKAN DENGAN SOP

JAKARTA, 12 JANUARI 2007

P3B BIDTEK

P3B UBOS

RJKB

RJBR

A. IKA DEWI

SOLIDA

SUMARYADI

ABIDIN S

RJTD

MD NUGROHO

RJTB

SUPONO S

8 of 8

Você também pode gostar