Você está na página 1de 8

Flange Haunch

Standard: EC3

Flange Haunch Description


Connection Details
Plate: 500mmx220mmx20mm
Bolts: 20mm 10.9 (As = 0m)
Spacing between vertical bolt lines 135mm
Group 1: lines = 1
Distance (from upper side of the plate) = 50mm
Interm. dist. Between bolts from group 1 = 155mm
Group 2: lines = 3
Distance (from previous bolts) = 100mm
Interm. dist. Between bolts from group 2 = 100mm
Total bolts number: 10
Connected elements
Element
Profiles

Height

Width

Column

HEB300

300mm

300mm

Web
thicknes
s
11mm

Rafter

IPE300

300mm

150mm

7.1mm

Design efforts
Case name
SimpleMaxTorsor

M
-9.1kNm

N
438.6kN

Flange
thicknes
s
19mm

Roundin
g radius

Material

Id

27mm

10.7mm

15mm

S235JR
G2
S235JR
G2

V
3.1kN

Welds thickness
Weld name
Secondary beam - flange plate
Secondary beam - web plate
Bolt properties
Connecting
Type
Column End plate

14399-4

Diameter
20mm

Thickness
6mm
6mm

Number of
bolts
10

Grade

Assembly

10.9

Mu2S

Hole
diameter
2mm

Area
0m

Bolt Verification
Conditions
Min/Max bolt edge distance (on load direction)
1.2 * d0 e1 (4 * t + 40mm)
26.4mm 50mm 116mm
OK
Min/Max bolt edge distance (perpendicular on load direction)
1.2 * d0 e2 (4 * t + 40mm)
26.4mm 42.5mm 116mm
OK
Min/Max bolt spacing distance (on load direction)
2.2 * d0 p1 min(14 * t; 200mm)
48.4mm 100mm 200mm
OK
Bolt Shear Verification
Fv,Ed Fv,Rd
VEd / (nObj * n) ns * v * fub * As / Mb
3.1kN / (1 * 10) 1 * 0.5 * 1000N/mm * 0m / 1.25
0.3kN 98kN
0.32 %
OK
Bolt Bearing Verification
Bolt bearing on plate
Fv,Ed Fb,Rd
Fv,Ed 1 * k1 * b * fu * d * (ti ) / Mb
0.3kN 1 * 2.5 * 0.76 * 360N/mm * 20mm * 20mm / 1.25
0.3kN 218.2kN
0.14 %
OK
Bolt bearing on main beam
Fv,Ed Fb,Rd
Fv,Ed 1 * k1 * b * fu * d * (ti ) / Mb
0.3kN 1 * 2.5 * 1 * 360N/mm * 20mm * 19mm / 1.25
0.3kN 273.6kN
0.11 %
OK
Bolt Tension Verification
Ft,Ed Ft,Rd
MEd * h1 / (nv * (hr 2 )) + NEd / (nObj * nt ) k2 * fub * As / Mb
9.1kNm * 344.65mm / (2 * 0.2m) + 438.6kN / (1 * 10) 0.9 * 1000N/mm * 0m / 1.25
51.6kN 176.4kN
29.27 %

OK
Bolt Punching Shear Resistance
Ft,Ed Bp,Rd
Ft,Ed 0.6 * * dm * tp * fu / Mb
51.6kN 0.6 * 3.14 * 35.03mm * 19mm * 360N/mm / 1.25
51.6kN 361.3kN
14.29 %
OK
Bolt Shear And Tension Verification
Fv,Ed / Fv,Rd + Ft,Ed / (1.4 * Ft,Rd ) 1
0.3kN / 98kN + 51.6kN / (1.4 * 176.4kN) 1
0.21 1
OK
Design Tension Resistance - Individual Bolt Rows
Bolt row 1:
Ft1,Ed Ft1,Rd
nv * [MEd * h1 / (nv * (hr 2 )) + NEd / (nObj * nh,t )] min(Ft1,wc,Rd ; Ft1,fc,Rd ; Ft1,ep,Rd )
2*[9.1kNm * 344.65mm / (2 * 0.2m) + 438.6kN / (1 * 10)] min(544.9kN; 325.6kN; 235.3kN)
103.3kN 235.3kN from(Design tension resistance for end plate in bending)
43.9 %
OK
Bolt row 2:
Ft2,Ed Ft2,Rd
nv * [MEd * h2 / (nv * (hr 2 )) + NEd / (nObj * nh,t )] min(Ft2,wc,Rd ; Ft2,fc,Rd ; Ft2,ep,Rd ; Ft2,wb,Rd )
2*[9.1kNm * 244.65mm / (2 * 0.2m) + 438.6kN / (1 * 10)] min(544.9kN; 346.2kN; 312.2kN;
572.2kN)
98.8kN 312.2kN from(Design tension resistance for end plate in bending)
31.64 %
OK
Bolt row 3:
Ft3,Ed Ft3,Rd
nv * [MEd * h3 / (nv * (hr 2 )) + NEd / (nObj * nh,t )] min(Ft3,wc,Rd ; Ft3,fc,Rd ; Ft3,ep,Rd ; Ft3,wb,Rd )
2*[9.1kNm * 144.65mm / (2 * 0.2m) + 438.6kN / (1 * 10)] min(544.9kN; 316.3kN; 283.3kN;
470.1kN)
94.3kN 283.3kN from(Design tension resistance for end plate in bending)
33.27 %
OK
Bolt row 4:
Ft4,Ed Ft4,Rd
nv * [MEd * h4 / (nv * (hr 2 )) + NEd / (nObj * nh,t )] min(Ft4,wc,Rd ; Ft4,fc,Rd ; Ft4,ep,Rd ; Ft4,wb,Rd )
2*[9.1kNm * 44.65mm / (2 * 0.2m) + 438.6kN / (1 * 10)] min(544.9kN; 346.2kN; 283.3kN;
470.1kN)
89.7kN 283.3kN from(Design tension resistance for end plate in bending)
31.67 %
OK

Design Tension Resistance - Group of Bolt Rows


Bolt rows 2-3:
(Ftr,Ed ) min(Ft2-3,wc,Rd ; Ft2-3,fc,Rd ; Ft2-3,ep,Rd ; Ft2-3,wb,Rd )
193kN min(695.6kN; 401.9kN; 509.8kN; 739.1kN)
193kN 401.9kN from(Design tension resistance for column flange in bending)
48.02 %
OK
Bolt rows 3-4:
(Ftr,Ed ) min(Ft3-4,wc,Rd ; Ft3-4,fc,Rd ; Ft3-4,ep,Rd ; Ft3-4,wb,Rd )
184kN min(673.5kN; 377.2kN; 469.1kN; 595.3kN)
184kN 377.2kN from(Design tension resistance for column flange in bending)
48.77 %
OK
Bolt rows 2-3-4:
(Ftr,Ed ) min(Ft2-3-4,wc,Rd ; Ft2-3-4,fc,Rd ; Ft2-3-4,ep,Rd ; Ft2-3-4,wb,Rd )
282.8kN min(766.5kN; 501.2kN; 695.6kN; 864.2kN)
282.8kN 501.2kN from(Design tension resistance for column flange in bending)
56.42 %
OK

Shear Verification of the Plate


Shear Yielding Verification
VEd Vpl,Rd
VEd nObj * fy * Av / (M0 * SQRT(3))
3.1kN 1 * 235N/mm * 0.01m / (1 * 1.73)
3.1kN 1356.8kN
0.23 %
OK
Shear Ultimate Verification
VEd Vu,Rd
VEd nObj * 0.9 * fu * Av,Net / (M2 * SQRT(3))
3.1kN 1 * 0.9 * 360N/mm * 0.01m / (1.25 * 1.73)
3.1kN 1167.3kN
0.27 %
OK
Block Tearing Verification
VEd Veff,1,Rd
VEd nObj * (fu * Ant / M2 + fy * Anv / (M0 * SQRT(3)))
3.1kN 1 * (360N/mm * 0m / 1.25 + 235N/mm * 0.01m / (1 * 1.73))
3.1kN 2267.8kN
0.14 %
OK

Column Verification

Column Web Panel in Shear


Conditions
d / tw 69 *
208mm / 11mm 69 * 1
18.91 69
OK
Column web panel in shear
Vwp,Ed Vwp,Rd
MEd / hf + NEd / 2 0.9 * fy,wc * Avc / (SQRT(3) * M0 )
9.1kNm / 289.3mm + 438.6kN / 2 0.9 * 235N/mm * 0m / (1.73 * 1)
250.8kN 579.4kN
43.28 %
OK
Column Web in Transverse Compression
Verification not necessary
Fc,wc,Ed Fc,wc,Rd
MEd / hf - NEd / 2 min( * kwc * beff,c,wc * twc * fy,wc / M0 ; * kwc * * beff,c,wc * twc * fy,wc /
M1 )
9.1kNm / 289.3mm - 438.6kN / 2 min(0.81 * 1 * 277.67mm * 11mm * 235N/mm / 1, 0.81 * 1 *
1 * 277.67mm * 11mm * 235N/mm / 1)
578.7kN = min(578.7kN; 578.7kN)
-187.8kN 578.7kN
32.46 %
OK

Weld Verification
Secondary Beam Flange - Plate
Minimum weld thickness
3 mm a
3mm 6mm
OK
Minimum weld length
max(30mm; 6 * a) leff
36mm 44.45mm
OK
Weld verification
Fw,Ed,Res Fw,Rd
MEd / hf + NEd / 2 nObj * nw * fvw,d * a * leff
9.1kNm / 289.3mm + 438.6kN / 2 1 * 1 * 207.8N/mm * 6mm * 226.9mm
250.8kN 283kN
88.62 %
OK
Secondary Beam Web - Plate

Minimum weld thickness


3 mm a
3mm 6mm
OK
Minimum weld length
max(30mm; 6 * a) leff
36mm 236.6mm
OK
Weld verification
Fw,Ed,Res Fw,Rd
VEd nObj * nw * fvw,d * a * leff
3.1kN 1 * 2 * 207.8N/mm * 6mm * 236.6mm
3.1kN 590.1kN
0.53 %
OK

Rotational Stiffness
Moment - Rotation Diagram

Stiffness - Rotation Diagram

Conclusion
The connection is correctly designed to resist the applied forces