Você está na página 1de 4

Page 1 of 4

Bangalore.mit
3 January 2016

INTEGRATED
ENVIRONMENTAL
SOLUTIONS LTD

LEED -India

TRANSLATE

LEED-India - Day lighting credit


Analysis #

Date Time

3 January
2016 at
02:04

Daylight
Daylight
illumination factor%(area
(lux)area
weighted)
weighted

388.2

3.6

Copyright 2012 IES Limited All rights reserved

% area
meeting
targets

83.8

Analysis1:
LEED-India-New Construction (v1.0)
Light penetration through internal windows
Building floor area
Selected room area
No. of spaces in building
Selected number of occupied rooms
External windows area % of ext wall

1. The daylight analysis


provides an assessment of
daylight performance against
a fixed threshold

115.2 m2
115 m2
4
4
9%

Result:

Analysis #1...
1 credit

Pass
Spaces 84% pass (75% required)
Room by room last analysis2:
Utilise the summary data to assess improvements to rooms with % area
results between 50 to 75%; these rooms could be candidates for
adjustment

2. Things to consider:
Increasing the amount of
glazing should be assessed
as trade off with energy
consumption (heat loss and
solar gain
Evaluate the size and shape
of glazing; glass below desk
height has very little value;
glass at high level close to
light coloured soffits can
improve light penetration and
surface contrast
Glass selection, especially
solar glass, can significantly
affect visible light
transmittance (Tvis); modern
solar glass now offers better
light transmission with good
solar performance

Notes:
This analysis provides an assessment of the LEED-India day lighting
credits. The provision of daylight has been calculated in accordance with
the guidance provided in LEED guidance - simulation option.

file:///C:/Users/User/OneDrive/Bangalore/Toolkits/Daylighting/LEED/IND/Daylighting.html

Daylight is a perception
metric; large contrasts in
daylight in rooms reduces the
perception of how well the

3/1/16

Page 2 of 4

This analysis does not include an analysis of atria spaces (if selected
they will not be treated or tested separately); it is recommended the user
carry out a radiance analysis for such spaces.
It should be noted that the performance of devices such as light shelves
are best analysed using sunny skies; it is recommended that the user
carry out a detailed radiance analysis

Room
name
Sort A-Z
Apply

Analysis details:
1 - First
Floor
floor
Building
Ground
1Floor
ground
Building
Ground
2 - First
Floor
floor
Building
Ground
2Floor
Ground

89.5

424.6

4.0

0.39

yes

59.6

282.1

2.6

0.49

no

96.5

460.1

4.3

0.36

yes

89.5

385.9

3.6

0.33

yes

Location:
Calculated:
Sky Model:
Working plane:
Grid Size:

Bangalore, India
(12.97 N,77.58 E)
3 January 2016 2:04 AM
CIE Clear sky on 21st September at 12 pm
0.762 m
0.610 m

Copyright 2012 IES Limited All rights reserved

whole room is day lit;


especially consider sufficient
day light on ceilings and walls
Evaluate other day lighting
metrics such as glare; over
day lighting spaces can cause
glare and lead to blinds down
and lights on; the opposite
result
Consider day lighting with
other holistic comfort
requirements such as
occupant views and natural
ventilation. Blinds clashing
with these issues can lead to
a dysfunctional design.
Consider a zoned window
design with features such as
clerestories, light shelves etc
Internal surface reflactances
are 80% for ceilings, 50% for
walls and 20% for floors

file:///C:/Users/User/OneDrive/Bangalore/Toolkits/Daylighting/LEED/IND/Daylighting.html

3/1/16

Page 3 of 4

LEED-India - Day lighting credit


Room name

Template

Floor

Working plane(m)

Area meeting targets %

Average daylight(lux)

Sort A-Z

Sort A-Z

Hi/Lo

Hi/Lo

Hi/Lo

0.8

75.0

Apply

Uniformity ratio

LEED India pass

Hi/Lo

Average daylight factor


%
Hi/Lo

Hi/Lo

Pass/Fail

300.0

2.0

0.5

Building 1 - First floor

default

Ground Floor

0.76

89.5

424.6

4.0

0.39

Building 1 - ground

default

Ground Floor

0.76

59.6

282.1

2.6

0.49

no

Building 2 - First floor

default

Ground Floor

0.76

96.5

460.1

4.3

0.36

yes

Building 2 - Ground

default

Ground Floor

0.76

89.5
385.9
Copyright 2012 IES Limited All rights reserved

3.6

0.33

yes

file:///C:/Users/User/OneDrive/Bangalore/Toolkits/Daylighting/LEED/IND/Daylighting.html

yes

3/1/16

Page 4 of 4

Appendix - Additional Daylighting Images

file:///C:/Users/User/OneDrive/Bangalore/Toolkits/Daylighting/LEED/IND/Daylighting.html

3/1/16

Você também pode gostar