Você está na página 1de 2

Perhitungan Kebutuhan Angin di PT.

Rumah Intan

1. Electroda Bawah dan Hydrolic lilin


d(diameter):220mm
tinggi:100mm
volume
=1/4.d2.t
=3,14.(220)2.100
4
=17270mm3
=0,017 lt/second
=0,9 lt/menit
=1,02 x 6(bar) x 8(juml silinder) x 6(release)
=293,76 lt/menit

2. Electroda Atas
d(diameter):100mm
tinggi:150mm
volume
=1/4.d2.t
=3,14.(100)2.150
4
=11775mm3
=0,011 lt/second
=0,66 lt/menit
=0,66 x 6(bar) x 24(juml silinder) x 12(release)
=1140,48 lt/menit

3. Hydrolic Supply
d(diameter):120mm
tinggi:175mm
volume
=1/4.d2.t
=3,14.(120)2.175
4
=16485mm3
=0,016 lt/second
=0,96 lt/menit
=0,96 x 6(bar) x 4(juml silinder) x 6(release)
=138,24 lt/menit

4. Penjepit Depan

Hydrolic Supply
d(diameter):50mm
tinggi:75mm
volume
=1/4.d2.t
=3,14.(50)2.75
4
=2943,75mm3

=0,0029 lt/second
=0,174 lt/menit
=0,174 x 6(bar) x 4(juml silinder) x 6(release)
=25,05 lt/menit

5. Mesin Manual
Penjepit Depan
Hydrolic Supply
d(diameter):150mm
tinggi:150mm
volume
=1/4.d2.t
=3,14.(150)2.150
4
=17662,5mm3
=0,017 lt/second
=1,02 lt/menit
=1,02 x 6(bar) x 2(juml silinder) x 30(release)
=367,2 lt/menit

Total kebutuhan
= 293,76 lt/menit + 1140,48 lt/menit + 138,24 lt/menit +
25,05 lt/menit + 367,2 lt/menit
=1964,73

lt/menit

Safety Factor =20%


Total Kebutuhan + Safety Factor =

lt/menit

1964,73 lt/menit + 20% = 2357,67

Você também pode gostar