Escolar Documentos
Profissional Documentos
Cultura Documentos
TECHNICAL MANUAL
UNDERWATER ACOUSTIC BEACON
MODEL DK120/90
FAX: 941-739-3201
Page 1 of 21
03-TM-0063 REV A
Page 2 of 21
TABLE OF CONTENTS
SECTION I ...........................................................................................................................................5
GENERAL INFORMATION .................................................................................................................. 5
1.1. INTRODUCTION.................................................................................................................................... 5
1.2. GENERAL DESCRIPTION................................................................................................................................. 5
SECTION II .................................................................................................................................... 7
INSTALLATION............................................................................................................................................. 7
2.1. GENERAL. ............................................................................................................................................... 7
2.2. INSTALLATION CRITERIA OF THE BEACON. ..............................................................................................7
2.3. SURVIVABILITY.................................................................................................................................................. 7
2.4. ENVIRONMENTAL............................................................................................................................... 7
2.5. MAINTENANCE..................................................................................................................................... 7
2.6. INSTALLATION PROCEDURES FOR THE DK120/90 AND THE N30A26 SERIES
MOUNTING KIT. ..................................................................................................................................... 8
2.7. INSTALLATION PROCEDURES FOR THE DK120/90 AND THE N30A21A MOUNTING KIT. .................................................................................................................................................................... 9
SECTION III .................................................................................................................................11
OPERATION ................................................................................................................................ 11
3.1. THEORY OF OPERATION. ..................................................................................................................................................... 11
SECTION IV .................................................................................................................................12
TESTING ............................................................................................................................ 12
4.1. GENERAL. ............................................................................................................................................. 12
4.2. BATTERY TESTING..........................................................................................................................................12
4.3. OPERATIONAL TESTING. .............................................................................................................................................12
SECTION V ..................................................................................................................................13
MAINTENANCE DK120/90 ....................................................................................................................... 13
5.1. GENERAL. ............................................................................................................................................. 13
5.2. BEACON CLEANING. ......................................................................................................................... 13
5.3. BEACON TESTING. ............................................................................................................................. 13
5.4. PRECAUTIONS. ........................................................................................................................................................................ 13
5.5. BEACON DISASSEMBLY. ................................................................................................................. 13
5.6. INFORMATION, REPLACEMENT, AND TESTING FOR 810-2042 BATTERY..................................... 13
5.7. BEACON OFF-CURRENT TEST. ......................................................................................................................... 17
5.8. BATTERY DISPOSAL. ...................................................................................................................................... 17
5.9. BEACON STORAGE. .......................................................................................................................... 17
SECTION VI ................................................................................................................................ 18
WARRANTY DK120/90 .............................................................................................................................. 18
03-TM-0063 REV A
Page 3 of 21
TABLE OF FIGURES
Figure 1. DK120/90 Underwater Acoustic Beacon Installed in Mounting Kits ...................................... 5
Figure 2. Water Switch Location on Beacon ............................................................................................ 5
Figure 3. N30A26 Series Mounting Kit Installation Details ................................................................ 8
Figure 4. Installation of N30A26 Series Mounting Kit and Beacon ........................................................ 9
Figure 5. Mounting Hole Template for N30A21A Mounting Kit............................................................. 9
Figure 6. N30A21A Mounting Kit and Beacon Overall Dimensions ................................................ 10
Figure 7. Method of Installing the N30A21A Mounting Kit ............................................................. 10
Figure 8. Securing Beacon in N30A21A Mounting Kit .................................................................... 10
Figure 9. Nominal Pulse Train ......................................................................................................... 11
Figure 10. Typical Beacon Label ....................................................................................................................12
Figure 11. Beacon Voltage Code.............................................................................................................. 12
Figure 12. Battery End Cover Removal With Vise Clamp and Spanner Wrench .................................. 14
Figure 13. Battery Kit Part Number ..........................................................................................................15
Figure 14 Beacon Exploded View Showing Relative Location of Battery and Related Parts... ... 15
Figure 15. RBB Label Placement ............................................................................................................ 17
Figure 16. Beacon Off-Current Test Set-Up ...................................................................................................................... 17
03-TM-0063 REV A
Page 4 of 21
SECTION I
GENERAL INFORMATION
1.1. INTRODUCTION.
1.1.1. GENERAL. This manual contains the description, theory, installation and maintenance for the
DK120/90 Underwater Acoustic Beacon, manufactured
by Dukane Seacom, Inc., 7135 16th Street East, Suite 101,
Sarasota, FL 34243 These beacons have been tested to,
and meet, or exceed, all requirements of FAA TSOC121b.
03-TM-0063 REV A
Page 5 of 21
Operating Frequency...................................................
Operating Depth..........................................................
Pulse Length................................................................
Operating Life..............................................................
90 days (minimum)
Radiation Pattern..........................................................
Size...............................................................................
1.2.4. ENVIRONMENTAL TEST. The beacon complies with the preceding operational performance
standards after being subjected to environmental tests specified in FAA TSO-C121b.
03-TM-0063 REV A
Page 6 of 21
CONDITIONS
Condensation
SAE AS8045A
Section 5.1
TEST CONDITIONS
15 Cycles:
6hrs @ -9C
18hrs @ 35C and 95% RH
DO-160G, Section 4.5, Category D2
Temperature Storage
Temperature Variation
Vibration
Section 5.2
Section 5.3
Section 5.4
Section 5.5
Section 5.6
Section 5.7
Section 5.8
Section 5.9
Section 5.10
Section 5.11
Section 5.12
Section 5.13
Impact Shock
Impact
Static Crush
Pressure
Section 6.1
Section 6.2
Section 6.3
Section 6.4
03-TM-0063 REV A
Page 7 of 21
SECTION II
INSTALLATION
2.5. MAINTENANCE.
In addition to observance of the preceding mandatory considerations, where possible the selection of
a mounting location should provide for convenient
beacon access during inspection intervals. The proper mounting location should also provide for clearance for removing the beacon from its mounting hardware.
03-TM-0063 REV A
Page 8 of 21
NOTE
The mounting bracket can be used as a template
to mark for drilling the holes prior to the installation of beacon. Always remove beacon from
mount prior to marking or drilling.
CAUTION
WHEN MOUNTING TO THE AIR
FRAME, CHECK THE OPPOSITE SIDE
OF THE FRAME OR BULKHEAD FOR
DRILLING CLEARANCE.
WARNING
03-TM-0063 REV A
Page 9 of 21
03-TM-0063 REV A
Page 10 of 21
CAUTION
ADDITIONAL UNAPPROVED STAMP OR LA
BEL ON BEACON CASE WILL REDUCE
ACOUSTIC RADIATION.
D. Perform the Operational Test outlined in Section
IV.
03-TM-0063 REV A
Page 11 of 21
SECTION III
OPERATION
03-TM-0063 REV A
Page 12 of 21
SECTION IV
TESTING
4.1. GENERAL.
The DK120/90 beacon should be tested before and
after installation in the mounting kit and at recommended maintenance intervals. See Sections IV and
V.
4.2. BATTERY TESTING.
Use a high impedance voltmeter (input impedance
of 10 M ohms) (not required when using the TS200
Test Set) to perform the following
procedure:
A. Make sure the case and water switch are clean and
dry prior to testing. If in doubt, wipe clean using mild
detergent and a soft cloth.
B. Place the negative lead of the high impedance voltmeter on the water switch pin and the positive lead
of the meter on the beacon case or the mounting kit,
if already installed.
C. Measure the battery voltage. Note: Inspect label
on beacon to determine battery code. See Figure 10
and refer to Figure 11 for voltage specifications.
The beacon is operable at the given minimum acceptable voltage. If the battery voltage is below the
minimum acceptable voltage, remove the beacon
from service and either Replace the Battery per Section 5.6 or contact Dukane Seacom, Inc. for service.
MINIMUM ACCEPTABLE
VOLTAGE
2. 97 VOLTS
03-TM-0063 REV A
Page 13 of 21
SECTION V
MAINTENANCE DK120/90
5.1. GENERAL.
5.4.2. Any situation that could possibly crush or penetrate the case of the beacon should be avoided.
MANUFACTURES NAME .
Dukane Seacom, Inc.
WARNING
NEVER CHARGE, SHORT CIRCUIT, PUNC
TURE, DEFORM OR INCINERATE, HEAT
ABOVE 71 C, OR EXPOSE CONTENTS TO
WATER. REMOVE WHEN DISCHARGED .
03-TM-0063 REV A
Page 14 of 21
DATE OF MANUFACTURE.
D. Remove shock cushion from battery end of beacon if not removed with cover.
E. Remove the old O-ring from the cover. Do not use a
steel screwdriver or sharp tool because of danger of
damaging O-ring groove.
F. Remove the old battery. NOTE: Insure that the
battery pad remains in beacon.
G. Clean the threads, O-ring groove in the body and the
threads on the cover by wiping them thoroughly with solvent.
WARNING
CAUTION
INCORRECT INSTALLATION OF
BATTERY WILL CAUSE PERMA
NENT DAMAGE TO BEACON.
NOTE
Replacement of the battery in the DK120/90 beacon
must be done by a qualified technician.
03-TM-0063 REV A
Page 15 of 21
CODE
81 0 - 2042/K
( See Figure 15 )
03-TM-0063 REV A
Page 16 of 21
WARNING
REPLACE BATTERY WITH AUTHORIZED
REPLACEMENT PARTS ONLY. USE OF
AN UNAUTHORIZED BATTERY WILL
VOID THE WARRANTY AND MAY CAUSE
AN INOPERATIVE OR DANGEROUS
CONDITION. USE OF AN UNAU
THORIZED BATTERY MAY PRESENT A
RISK OF FIRE OR EXPLOSION. SEE FIG
URE 13 PAGE 15 FOR REPLACEMENT
BATTERY KIT.
CAUTION
03-TM-0063 REV A
Page 17 of 21
WARNING
DO NOT RECHARGE, DISASSEMBLE, HEAT
ABOVE 160F (71C) OR INCINERATE. THERE
IS A RISK OF BATTERY FIRE, EXPLOSION,
AND BURNS.
03-TM-0063 REV A
Page 18 of 21
SECTION VI
WARRANTY DK120/90
Dukane Seacom, Inc. warrants that the electronics and case of the Model DK120/90 Underwater Acoustic
Beacon (hereafter referred to as the unit) will be free from defects in materials and workmanship for six
years from the date of shipment from Dukane Seacom, Inc. Dukane Seacom, Inc. will remanufacture or replace any unit or battery found not to be in conformity with this warranty.
In accordance with the Technical Manual published by Dukane Seacom, Inc. the customer is responsible
for the following items: (1) periodic testing of the units in service; (2) removing and shipping, prepaid, any
inoperative units back to Dukane Seacom, Inc. (3) installing any replacement units.
This warranty does not cover: (i) defects caused by the customers failure to use, test or maintain any unit in
accordance with Dukane Seacom, Inc. Technical Manual; (ii) product failures caused by abuse, misuse or
neglect; (iii) corrosion, oxidation, abrasion, rust, surface damage, weather conditions, variations in environ
-ment that affect the appearance or operation of products; (iv) any product where the customer has attempted any repair or service of the internal components.
Dukane Seacom, Inc. liability under this warranty is limited to repair or replacement of a unit or battery
that is defective.
DUKANE SEACOM, INC. SHALL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL CONSEQUENTIAL OR EXEMPLARY DAMAGES ARISING OUT OF THE INSTALLATION, USE, TESTING, SERVICING OR MAINTENANCE OF ANY UNIT.
THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
03-TM-0063 REV A
Page 19 of 21
SECTION VII
SERVICE PROGRAM DK120/90
7.4. BATTERY CHANGE/OVERHAUL FOR THE
DK120/90.
Notes:
1. See Section VIII for information about how to return the beacon to Dukane Seacom, Inc. for service.
2. Call Dukane Seacom, Inc. or authorized dealer for appropriate service charges or further information about
the Service Program.
03-TM-0063 REV A
Page 20 of 21
SECTION VIII
PROCEDURE FOR RETURNING DK120/90
BEACON TO FACTORY
8.1. BEACON SERVICE.
NOTE:
The DK120/90 is powered by a Lithium
Battery that contains 1.7g of Lithium.
Special shipping, packing, and labeling
procedures must be followed per IATA
Dangerous Goods Regulations.
8.1.1. PACKAGING. Insure that proper protection for the beacon is provided i.e. protection
from inadvertent shorting of the water switch
and protection from surface scratches or abrasions.
8.1.2. INFORMATION TO BE INCLUDED
WITH THE BEACON.
A. Reason for the return.
B. Serial Number of the beacon (s).
C. Return Authorization Number (See 8.1.3.).
D. Purchase Order (if required) for Beacon
Replacement.
8.1.3. RETURN AUTHORIZATION. Prior to
shipping the beacon, a Return Authorization Number may be required and can be obtained from Dukane
Seacom, Inc. or authorized dealer.
Or
Seal Dynamics
Attn: Returns Dept
600 Prime Place
Hauppauge, NY USA 11788
(631) 667-4000 x2158
03-TM-0063 REV A