Você está na página 1de 14

GROUP 12 MONITORING SYSTEM

1. OUTLINE
Monitoring system consists of the monitor part and switch part.
The monitor part gives warnings when any abnormality occurs in the machine and informs the
condition of the machine.
Various select switches are built into the monitor panel, which act as the control portion of the machine
control system.

2. CLUSTER
1) MONITOR PANEL

RPM display

Clock display

Fuel gauge
Hyd oil temp gauge

Engine coolant temp gauge

Air cleaner warning lamp

CPU controller
check warning lamp

Coolant level warning lamp

Power max pilot lamp

Engine oil pressure warning lamp

Preheat pilot lamp

Battery charging warning lamp

Warming up pilot lamp

Overload warning lamp

Decel pilot lamp

Work mode switch


Power mode switch
Travel speed switch
User mode switch
Buzzer stop switch
Auto deceleration switch

Select switch

30075MS01

5-24

2) CLUSTER CHECK PROCEDURE


(1) Start key : ON
Check monitor initial 5 seconds
a. All lamps light up.
b. Buzzer sound.
Check monitor after 5 seconds : Indicate cluster version and machine condition
:
Indicates program version1.00for 5 seconds.
a. Cluster program version 1.00
b. Tachometer : 0rpm
c. Fuel gauge : All light up below appropriate level
d. Hydraulic temperature : All light up below appropriate level
e. Engine coolant temperature gauge : All light up below appropriate level
f. Warning lamp
During start key ON the engine oil pressure lamp and battery charging lamp go on, but it is not
abnormal.
C, the warming up lamp lights up.
When engine coolant temperature below 30
Indicating lamp state
a.
b.
c.
d.
e.

Work mode selection : General work


Power mode selection : S mode
User mode selection : No LED ON
Auto decel LED : ON
Travel speed pilot lamp : Low(Turttle)

(2) Start of engine


Check machine condition
a. Tachometer indicates at present rpm
b. Gauge and warning lamp : Indicate at present condition.
When normal condition : All warning lamp OFF
c. Work mode selection : General work
d. Power mode selection : S mode
e. User mode selection : No LED ON
f. Auto decel LED : ON
g. Travel speed pilot lamp : Low(Turttle)
When warming up operation
a. Warming up lamp : ON
b. 10 seconds after engine started, engine speed increases to 1000rpm(Auto decel LED : ON)
Others same as above 
When abnormal condition
a. The lamp lights up and the buzzer sounds.
b. If BUZZER STOP switch is pressed, buzzer sound is canceled but the lamp light up until
normal condition.

5-25

3. CLUSTER CONNECTOR
No.

Signal

Input / Output

Power IG(24V)

Input(20~32V)

GND

Serial-(RX)

Input(Vpp=12V)

Serial+(TX)

Output(Vpp=4V)

Cluster

Input(0V)

1
2

4
3

21075MS16

5-26

4. CLUSTER FUNCTION
1) LCD main operation display
Option screen
screen
Option

Default screen
screen
1

2
4

1
4
3
5

1607A3CD02A

1607A3CD02B

1
2
3
4
5

Time display
RPM display
Hydraulic oil temperature gauge
Fuel level gauge
Engine coolant temperature gauge

(1) Time display


This displays the current time.
Refer to the page 5-31 to set time for details.
1607A3CD02C

(2) RPM display


This displays the engine rpm.
1607A3CD02C

(3) Hydraulic oil temperature gauge


This gauge indicates the temperature of hydraulic oil in 12 step
12th step
gauge.
1st step
: Below 30
C(86
F)
2nd~10th step : 30-105
C(86-221
F)
11th~12th
step
:
Above
105
C(221
F)
1st step
1607A3CD02D
The gauge between 2nd and 10th steps illuminates when
operating.
Keep idling engine at low speed until the gauge between 2nd
and 10th steps illuminates, before operation of machine.
When the gauge of 11th and 12th steps illuminates, reduce the
load on the system. If the gauge stays in the 11th~12th steps,
stop the machine and check the cause of the problem.
(4) Fuel level gauge
1st step

1607A3CD02E

This gauge indicates the amount of fuel in the fuel tank.


Fill the fuel when the 1st step or fuel icon blinks in red.
If the gauge illuminates the 1st step or fuel icon blinks in
red even though the machine is on the normal condition,
check the electric device as that can be caused by the poor
connection of electricity or sensor.

(5) Engine coolant temperature gauge


12th step

1st step
1607A3CD02F

This gauge indicates the temperature of coolant in 12 step


gauge.
1st step
: Below 30
C(86
F)
2nd~10th step : 30-105
C(86-221
F)
11th~12th step : Above 105
C(221
F)
The gauge between 2nd and 10th steps illuminates when
operating.
Keep idling engine at low speed until the gauge between 2nd
and 10th steps illuminates, before operation of machine.
When the gauge of 11th and 12th steps illuminates, turn OFF
the engine, check the radiator and engine.
5-27

3) Warning of main operation screen


(1) Warning display
Engine coolant temperature
- This lamp blinks and the buzzer sounds
when the temperature of coolant is over
the normal temperature 105
C 221
F) .
- Check the cooling system when the lamp
blinks.
Fuel level
- This lamp blinks and the buzzer sounds
when the level of fuel is below 49(12.9
U.S. gal).
- Fill the fuel immediately when the lamp
blinks.
Hydraulic oil temperature
- This warning lamp operates and the
buzzer sounds when the temperature of
hydraulic oil is over 105
C 221
F) .
- Check the hydraulic oil level when the
lamp blinks.
- Check for debris between oil cooler and
radiator.
All gauge
- This lamp blinks and the buzzer sounds
when the all gauge is abnormal.
- Check the each system when the lamp
blinks.
Communication error
- Communication problem between MCU
controller and cluster makes the lamp
blinks and the buzzer sounds.
- Check if any fuse for MCU burnt off.
If not check the communication line
between them.
(2) Pop-up icon display
No

Switch

Selected mode

Display

1 Work mode General work


mode
switch

No

Switch

Selected mode

3 Auto
Light ON
deceleration
switch

Heavy duty
work mode

Light OFF
4 Travel speed
Low speed
control
switch

Breaker
operation mode
2 Power mode High power
switch
work mode

High speed

Standard power
work mode

5-28

Display

4) LCD

SYSTEM MENU

Monitoring

Diagnosis

Management

Settings

Display

User Mode

2
4

: LCD

: Escape,
Return to the previous menu

: Down/Left Direction

: Up/Right Direction

: Select(Enter)
Activate the currently chosen item

2507A4OP95B

(1) Main menu


1

: Menu information

: Monitoring
Equipment, Switch, Output

: Diagnosis
Current error, Recorded error

: Maintenance

: Settings
Time set Dual mode
System lock(Reserved)

: Display
Operation skin, Brightness, Language

: User mode

2507A4OP94

5-29

(2) Display map


Monitoring

Diagnosis
- If there are more than 2 error codes, each one can be displayed by pressing
switch respectively.

Maintenance

5-30

or

Setting
a. Time set

: Adjusting
: Setting

b. System lock - Reserved

c. Dual mode
- Changing the MCU mode

Display
a. Operation skin

b. Brightness

c. Language

5-31

User mode

Usermode(U) is not selected.

: Adjusting

: Adjusting

: Adjusting

: Setting

: Setting

: Setting

5-32

5) Warning and pilot lamp


(1) Engine oil pressure warning lamp
This lamp blinks and the buzzer sounds after starting the
engine because of the low oil pressure.
If the lamp blinks during engine operation, shut OFF engine
immediately. Check oil level.
21073CD07

(2) Air cleaner warning lamp


This lamp blinks and the buzzer sounds when the filter of air
cleaner is clogged.
Check the filter and clean or replace it.

21073CD08

(3) MCU controller check warning lamp


If any fault code is received from MCU controller, this lamp
blinks and the buzzer sounds.
Check the communication line between MCU controller and
cluster.
21073CD10

(4) Battery charging warning lamp


This lamp blinks and the buzzer sounds when the starting
switch is ON, it is turned OFF after starting the engine.
Check the battery charging circuit when this lamp blinks during
engine operation.
21073CD13

(5) Overload warning lamp (Option)


When the machine is overload, the overload warning lamp
blinks during the overload switch is ON.

21073CD15

5-33

(6) Power max pilot lamp


The lamp will be ON when pushing power max switch on the
LH RCV lever.

21073CD11

(7) Decel pilot lamp


Operating auto decel or one touch decel makes the lamp ON.
The lamp will be ON when pushing one touch decel switch on
the LH RCV lever.

21073CD17

(8) Warming up pilot lamp


This lamp is turned ON when the coolant temperature is below
30
C 86
F).
The automatic warming up is cancelled when the engine
coolant temperature is above 30
C, or when 10 minutes have
passed since starting.
21073CD18

(9) Preheat pilot lamp


Turning the start key switch ON position starts preheating in
cold weather.
Start the engine as this lamp is OFF.

21073CD12

(10) Work mode switch

21073CD20

This switch is to select the machine operation mode, which


shifts from general operation mode to heavy operation mode
and breaker mode in a raw by pressing the switch.

: Heavy duty work mode

: General work mode

: Breaker operation mode


Refer to the page 5-4 for details.

5-34

(11) User mode switch


This switch is to select the maximum power or user mode.
M : Maximum power
U : Memorizing operators preferable power setting.
Refer to the page 5-5 for details.
1607A3CD21

(12) Auto deceleration switch

1607A3CD22

This switch is used to actuate or cancel the auto deceleration


function.
When the switch actuated and all control levers and pedals are
at neutral position, engine speed will be lowered automatically
to save fuel consumption.
Light ON : Auto deceleration function is selected.
Light OFF : a. Auto deceleration function is cancelled so that
the engine speed increased to previous setting
value.
b. One touch decel function is available.

(13) Power mode switch


The lamp of selected mode is turned ON by pressing the
switch(
).
H : High power work.
S : Standard power work.
21073CD23

(14) Travel speed control switch


This switch is to control the travel speed which is changed to
high speed(Rabbit mark) by pressing the switch and low
speed(Turtle mark) by pressing it again.

21073CD24

(15) Buzzer stop switch

1607A3CD25

When the starting switch is turned ON first, normally the alarm


buzzer sounds for 2 seconds during lamp check operation.
The red lamp lights ON and the buzzer sounds when the
machine has a problem.
In this case, press this switch and buzzer stops, but the red
lamp lights until the problem is cleared.

5-35

(16) Select switch


This switch is used to enter main menu and sub menu of LCD.
Refer to the page 5-29 for details.

1607A3CD25A

5-36

6
5

3
2

ST C

BR ACC

CS-2

CN-74

GrW

7
RW

Gr

85
87a

SPARE

FUEL WARMER

FUEL FILLER P/P

SOLENOID 3

SAFETY SOL

SOLENOID 1

TRAVEL

PRE-HEAT

CIGAR LIGHTER

HORN

AC& HEATER

BEACON LAMP

CABIN LAMP

WORK LAMP

HEAD LAMP

WIPER MOTOR

ALTERNATOR "R"

SWITCH PANEL

CONVERTOR

CPU

CASSETTE RADIO

CLUSTER

AC BLOWER

CPU B+

WIPER+

AC& HEATER

ROOM LAMP

START KEY

CN-36

86
87
30 86

87a 87 85

20A

10A

10A

10A

5A

10A

5A

10A

10A

10A

20A

5A

10A

10A

5A

20A

20A

5A

5A

10A

5A

10A

20A

5A

10A

5A

5A

20A

W CR-35
30
87a 87 85
R
86
3L
87
B
85
30 86
87a

YW

G/W

CR-36
30

CN-3

5
3

5R

5R

3L

CS-74

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

FUSE BOX

BW

1) The current of fuel warmer system is automatically


controlled without thermostat according to fuel
temperature.
2) At the first state, the 15A current flows to the fuel
warmer and engine may be started in 1~2
minutes.
3) If the fuel starts to flow, ceramic-disk in the fuel
warmer heater senses the fuel temperature to
reduce the current as low as 1.5A.
So, fuel is protected from overheating by this
mechanism.

CN-95

1
2

CN-60

1
2

60R

CN-147

FUEL HEATER RY

CR-46

34

33

RS232 (RXD)

START RY

36

32

RS232 (TXD)

Gr

35

31

GND

Gr
2

BOOM DOWN EPPR(+)

30

SERIAL-RX

RS232 (GND)

29

SERIAL-TX

PUMP EPPR(+)

28

GND (MAIN)

23

ACCEL ACT(-)

27

22

26

21

ENG OIL FILTER SW

NC

CAN_GND(J1939-GND)

20

CR-23

5-37

24

19

OVERLOAD SIG

CN-45

RW

CPU CONTROLLER

25

18

HEAD LAMP SWITCH

PARKING SW

POWER IG

17

PRE-HEAT SW

CAN_H(J1939+)

16

TRAVEL BUZZER

CAN_L(J1939-)

15

13

TRAVEL SOLENOID

AIR-GRID
HEATER

14

12

ACCEL ACT(+)

STARTER

T/M OIL LAMP

11

ANTI-RESTART RY

Gr

B+

BRAKE FAIL LAMP

10

PUMP EPPR(-)

BOOM DOWN EPPR(-)

BW

YW

12

CPU PROGRAM DUMP

FUEL WARMER

BATTERY 24V(+)

POWER MAX SOL

HOUR-METER

MAX FLOW SOL

ENG PRE-HEATER

CN-50

11

10

CN-8

BOOM PRIORITY SOL

H 0 I

POWER RY

RW

START KEY SW

PRE-HEATER
COIL RY

0, I

GROUP 13 FUEL WARMER SYSTEM

1. SPECIFICATION

1) Operating voltage : 244V


2) Power : 20050W
3) Current : 15A

2. OPERATION

Prefilter

Fuel heater

8007A5MS10

3. ELECTRIC CIRCUIT
5R
5W

CS-74

MASTER SW

5W
5W

5R

FUSIBLE LINK
5R

CR-1
60B

BATTERY
(12VX2)

BATT RY

CN-78

CR-24

GrW

HEATER RY

FUEL HEATER

30007A5MS13

Você também pode gostar