TEXAS FIRM REGISTRAGTION NO.

F-12745
4800 SUGAR GROVE, SUITE 315
STAFFORD. TEXAS 77477
T 713.933.1041
F 713.458.7758
www.ensighthayneswhaley.com
EHW-15-501-A

Issue
No.

Date

3
2 1/4" MIN
TYPICAL

01-18-2016

#4 SUPPORT BARS
TYPICAL

2-#4 BACKUP BARS


BEHIND EACH
ANCHOR
EACH WAY -TYPICAL

1'-0" MINIMUM

Description
FINISH GRADING, SUPERSTRUCTURE AND
GARAGE PERMIT PACKAGE

9"

SEE BEAM SCHEDULE

CGS OF BM TENDONS
SEE BEAM SCHEDULE

SEE
PLAN

SEE BEAM SCHEDULE

"t"

BEAM TENDONS

CONSTRUCTION JOINT
CONSTRUCTION JOINT

COLUMN BELOW

CONCRETE WALL/COLUMN
NOTE:
FOR END OF BEAM TENDON
ANCHORS, SEE DETAIL

20
ADDITIONAL #4 @ 12"

DOWELS EACH SIDE OF POUR STRIP (3 MINIMUM


ON EACH FACE). OBTAIN SIZE AND QUANTITY
FROM ENGINEER OF RECORD.

SHEAR KEYS
3"x1 1/2" TYPICAL

3" MAX

POUR STRIP RE PLAN

19

BEAM TO INTERIOR COLUMN / BEAM


SCALE: NOT TO SCALE

BEAM TO EXTERIOR COLUMN


SCALE: NOT TO SCALE

4'-0" MINIMUM STRAIGHT

CONTINUOUS TOP BAR


SEE SCHEDULE

SHEAR KEY

STRAND TAIL

2'-0" MINIMUM

SCHED BEAM
RENIFORCEMENT

16

"t"

SEE BEAM SCHEDULE

t/2

"t"

SEE BEAM SCHEDULE


FOR REINFORCEMENT

STIRRUPS, SEE BEAM


SCHEDULE FOR SIZE
AND SPACING

PT TENDONS AT
SUPPORT
CONDITION
(2) #4 CONTINUOUS

POST-TENSIONED ANCHOR
SIZE VARIES WITH
MANUFACTURER
TYPICAL

3/4" CHAMFER
TYPICAL
CONTINUOUS BOTTOM BAR
SEE SCHEDULE

2'-0"

CLASS 'B' SPLICE

PT TENDONS AT
MID
SPAN
CONDITIONS

SEE BEAM
SCHED

CONCRETE COLUMN

2" CLR

TEMPORARY
SUPPORT POINT
NOTE: FOR TRIM REINFORCEMENT AROUND
OPENINGS SEE TYPICAL SLAB OPENING DETAIL

NOTE:
1. FILL IN POUR STRIP ONLY WHEN ALL POST-TENSIONING OPERATIONS ON
BOTH SIDES OF THE STRIP ARE COMPLETED.
2. REMOVE TEMPORARY SHORING ONLY WHEN THE CONCRETE IN THE POUR
STRIP HAS ATTAINED THE SPECIFIED 28-DAY STRENGTH.

NOTE:
1. ALL BARS SHOWN ON THE STRUCTURAL PLANS SHALL BE CONTINUOUS THROUGH THE
BLOCKOUT OR LAP-SPLICED.
2. FILL BLOCKOUT WITH CONCRETE OR NON-SHRINK CONCRETE REPAIR MATERIAL OF
SAME SPECIFIED STRENGTH AS SLAB CONCRETE.
3. IF BLOCKOUT WILL BE IN AN AGGRESSIVE ENVIRONMENT, SEAL ANCHORAGE POCKETS
PER THE PROJECT SPECIFICATIONS AND CAULK JOINT ALL AROUND WITH FLEXIBLE
SEALANT.

CG OF BEAM
CG OF TENDONS

PROVIDE #3 HAIRPINS @ 1'-0" AT


ALTERNATE TENDONS IN BAND WHER
TENDON SLOPE EXCEED 1:12

TEMPORARY
SUPPORT POINT

2'-6" MINIMUM

17

6" MIN

H/4

H/4

H/4

2'-0"

SCHEDULED BEAM
TIES

STRESSING BLOCKOUT
POST-TENSION TENDON PLACEMENT
SCALE: NOT TO SCALE

t/2

MAXIMUM CURVATURE
TYPICAL
6
1

H/4

SCHED BEAM DEPTH "H"

6"

3"
MIN

2'-0" BAR LAP


TYPICAL

PT TENDON

SEE BEAM SCHEDULE

6"

PT ANCHOR

SEE BEAM
SCHEDULE

15

POUR STRIP AT PT BEAMS


SCALE: NOT TO SCALE

NOTES:
1. FOR POST-TENSIONING TENDONS, SEE SCHEDULE
2. KEEP TENDON GROUPS UNIFORMLY SPACED THROUGHOUT
LENGTH OF BEAM

SEE COLUMN
SCHEDULE

14

TENDON LAYOUT AT OPENINGS


SCALE: NOT TO SCALE

13

END OF BEAM TENDON ANCHOR PLACEMENT


SCALE: NOT TO SCALE

1001 Fannin Street, Suite 4040 | Houston, Texas 77002 USA


Phone 713.622.1180 | Fax 713.622.7021
www.morris-hz.com
POST-TENSION TENDON PLACEMENT
SCALE: NOT TO SCALE

Project Team

STONEHENGE HOLDINGS LLC


OWNER

MORRIS
ARCHITECT

TYPICAL SUPPORT

TOP FLEXURAL BAR


AT FINAL POSITION

3'-0" U.N.O. ON PLAN


SEE PLAN FOR LOCATION

#4@10" CONT
TOP AND BOT

POINT OF TENDON
PROFILE SHOWN ON PT TENDON
PLAN

2" MIN
CLEAR TYP
UNIFORMLY
DISTRIBUTED
PT TENDONS

ALTERNATE SUPPORT

PT ANCHOR

TOP UPPER REBAR


SEE PLAN

EQUAL

#4 CONT SUPPORT
BAR (TYP)

UNIFORM TENDONS
BANDED PT
TENDONS

ENSIGHT HAYNES WHALEY, LLC

2" MIN
CLEAR TYP

EQUAL
3/4" COVER
MIN

TOP FLEXURAL BAR


MAY BE BENT TO 45
BANDED PT TENDONS
FOR STRESSING RAM
(4 PER BUNDLE)
CLEARANCE

SUPPORT WIDTH

3/4" CLR
MIN

SUPPORT REBAR
#6 MINIMUM
TYPICAL

CIVIL ENGINEER

3/4" COVER
MIN

CGS

STANDARD
CHAIR

TOP UPPER REBAR


TYPICAL

HUITT-ZOLLARS, INC.

00
45. X
MA

CGS

STANDARD
CHAIR

2" MIN CLR (TYP)


IN BOTH UNIFORM AND
BANDED DIRECTIONS

STRAND
TYPICAL

#4 MININIMUM
TYPICAL

1/4"

STRAND
TYICAL
3/4"

#4 MINIMUM
TYPICAL

(SUPPORT BAR ON TOP OF STRANDS)

3/4" COVER
MIN

(SUPPORT BAR BELOW STRANDS)

TOP UPPER REBAR


SEE PLAN

STRUCTURAL ENGINEER

BANDED PT TENDONS
(NUMBER OF TENDONS
PER BUNDLE MAY VARY)

BLUM CONSUTLING ENGINEER, INC.


MEP ENGINEER

THE OFFICE OF JAMES BURNETT


LANDSCAPE CONSULTANT

FERGUSON CONSULTING, INC.

TECHNOLOGY / SECURITY CONSULTANT


UNIFORMLY DISTRIBUTED PT
TENDONS (TIED TO BANDED
PT TENDONS, TYPICAL)

1/4"

CHAIR,
TYPICAL

TOP LOWER REBAR


(TYP)

PT SLAB

FOR DROP CAP SIZE


AND REINF SEE PLAN

SHEAR KEY
1 1/2"x3"x1'-0"@2'-0"

2-#4 CONT
3/4"
TYP

C.G.S.

SUPPORT
REBAR

CHAIR (TYP)

2" MIN
TYP

TEMPORARY
SUPPORT
POINT
.

SUPPORT BAR
OR BOLSTER

UNIFORMLY DISTRIBUTED
PT TENDONS

TOP LOWER REBAR


SEE PLAN

BOTTOM REINF
SEE PLAN (TYP)

BANDED TENDONS

BOTTOM FLEXURAL
REBAR
RE: PLAN LAP CONT

SUPPORT REBAR

CHAIRS, TYP

CHAIR, TYP

TEMPORARY
SUPPORT
POINT

TOP LOWER REBAR


SEE PLAN

4'-0" MAX WIDTH OF BANDED TENDONS


EXCEPT AT EXTERIOR SPANS, RE DETAIL

CENTER SUPPORT

SLAB BOLSTER SUPPORT


NOTE:
PROFILE OF BANDED TENDONS AT SUPPORT GOVERN.
AT SUPPORT, UNIFORM TENDONS WILL BE PLACED BELOW BANDED TENDONS,
LOWER THAN THE PROFILE SHOWN ON THE PLANS.

NOTE:
1. FILL IN POUR STRIP ONLY WHEN ALL POST-TENSIONING
OPERATIONS ON BOTH SIDES OF THE STRIP ARE COMPLETED.
2. REMOVE TEMPORARY SHORING ONLY WHEN THE CONCRETE IN
THE POUR STRIP HAS ATTAINED THE SPECIFIED 28-DAY STRENGTH.

NOTE: SEE PLAN FOR CENTER OF GRAVITY OF STRAND

12

11

CHAIRS AND SUPPORTS FOR TENDONS


SCALE: NOT TO SCALE

10

UNIFORMLY DISTRIBUTED DIRECTION


SCALE: NOT TO SCALE

1.5H

1.5H

09

08

SECTION THROUGH UNIFORM TENDONS


SCALE: NOT TO SCALE

DISTRIBUTED TENDONS
(6T OR 48" OC MAX
SPACING (TYP)

6" 6" 6"

3'-0"

07

SECTION THRU BANDED TENDON AT MID-SPAN


SCALE: NOT TO SCALE

1.5H

SECTION THRU BANDED TENDONS


SCALE: NOT TO SCALE

VARIES
PER PLAN

SUPPORT

SUPPORT BARS @ 42" MAX

1'-0" MIN

1.5H

L/4 OR 4'-0" MIN FROM FACE OF SUPPORT


CHAIR
TYP

BANDED TENDONS
4 PER BUNDLE, TYPICAL

1'-0"
2'-0"

TOP UPPER BAR @ 12" MAX SPACING, 4 BARS MIN

1.5H

SLAB EDGE

ADDED TENDON ANCHORAGES


SCALE: NOT TO SCALE

TOP UPPER DOWEL @ 12" O.C. MAX


4 BARS MINIMUM, TYPICAL

t/2 t/2

12

2-#4 CONT, MIN BACK-UP BARS


TYPICAL

06

3 - #5 TOP
AND BOTTOM

LEGEND:
T: SLAB THICKNESS
B,W: COLUMN SIZES
H: DEPTH OF SLAB & DROP CAP

05

PLAN DETAIL - REINFORCING AT INTERIOR SUPPORT


SCALE: NOT TO SCALE

BANDED TENDONS
(MAX 4 PER BUNDLE)
TYPICAL

1'-0" 2-0"

CL

DROP CAP WHERE SHOWN ON PLAN

MILD REINF (TOP LOWER) TYPICAL,12" MAX SPACING, 4


BARS MIN

ADDED
TENDONS

MILD REINF TO BE DISTRIBUTED WITHIN THE


DIMENSION LINES, EACH WAY

1.5H

1.5H

MINIMUM OF TWO TENDONS TO PASS DIRECTLY


OVER COLUMN, EACH WAY, TYPICAL

BANDED TENDONS

LIMIT OF BAND ANCHORS

DISTRIBUTED TENDONS
6T OR 48" O.C. MAX SPACING, TYPICAL

#4 x t TIES @
6" O.C., TYP
(t = SLAB THK)

4'-0" MAX WIDTH OF BAND

MILD REINFORCING TO BE DISTRIBUTED WITHIN


THE DIMENSION LINES, EACH WAY

TYPICAL MILD REINFORCEMENT


STAGGERED, EACH WAY,
TYPICAL

STAGGER DEAD-END ANCHORAGES


WHEN MORE THAN TWO ARE
PLACED IN ONE LOCATION

1'-0"

CONTINUOUS
TENDONS

1'-0"

2"

1'-0"

SECTION AT SLAB POUR STRIP


SCALE: NOT TO SCALE

NOTES:
1. FOR QUANTITY AND LENGTH OF REBAR, SEE PLAN.
2. FOR REBAR STAGGER, SEE DETAIL

NOTES:
1. ALTERNATE TENDON AND REBAR GROUPS.
2. FOR QUANTITY AND LENGTH OF REBAR, SEE PLAN.
3. FOR REBAR STAGGERED, SEE TYPICAL DETAILS

TOP LOWER DOWEL @ 12" OC MAX


4 BARS MINIMUM, TYPICAL
NOTE:
FOR BALANCE OF DETAIL SEE PLAN DETAIL REINFORCING
AT EXTERIOR SUPPORT

03

PLAN DETAIL - ANCHORAGE AT END OF BANDED TENDONS


SCALE: NOT TO SCALE

LEGEND:
T: SLAB THICKNESS
B,W: COLUMN SIZES
H: DEPTH OF SLAB & DROP CAP

TEXAS A&M CAIN HALL SITE


REDEVELOPMENT - VOLUME 6
500 GENE STALLINGS BOULEVARD,
COLLEGE STATION, TEXAS 77840
JANUARY 18, 2016
Project Number

SLAB EDGE

Drawing Name

A MINIMUM OF TWO (2) TENDONS AT SLAB EDGE, PARALLEL TO


DISTRIBUTED TENDONS ONLY

2 1/2 MIN

Project Name

3" OC TYP (WHERE SLAB IS 8" THICK OR LESS,


USE 6" OC SPACING & TURN ANCHORS 90) OR
AS REQUIREDD BY THE POST-TENSIONING
SYSTEM. FOR ADDL REINF SEE DETAIL S0X.XX

1
12
MAXIMUM
CURVATURE

01-18-2016

R303928.03

TYPICAL
POST-TENSION
DETAILS

NOTE: A MINIMUM OF TWO (2) TENDONS TO PASS DIRECTLY


OVER COLUMN, EACH WAY

Scale:

02

3/4" = 1'-0"

Drawing Number
PLAN DETAIL - REINFORCING AT EXTERIOR SUPPORT
SCALE: NOT TO SCALE

S-5.21