Você está na página 1de 4
‘Technical specifications for the Portable air-gun source ‘Name of the Item juantity Portable compressors * Electric three phase 400 volt AC 50 Hz. (vendor may provide transformer to meet the voltage requirement) © Free air Delivery (FAD): at least 300 /min @330bar © Continuous duty; sound attenuated; Protection against marine corrosion and all weather conditions ‘* Weight < 250 kg; Dimension Should not exceed 1.5mX1mX1m Pneumatic connections and mechanism to fill the storage cylinders simultaneously by two compressors. © Mechanism for auto turn on/off as the pressure reaches lower/higher threshold at the storage inlet. «Emergency stop push button 2Nos. High pressure storage and filling mechanism Total 400 liter capacity with mini. no. of cylinders @0-414 bar + High pressure air storage cylinders complying to intemational health & safety standards with documentary evidence ‘© With necessary long-life pneumatic connectors from compressor to storage and from storage to gun assembly Mechanism to latch/secure cylinders to durable vertical storage rack withstanding marine corrosion and all weather conditions ‘self venting regulator with safety valve on outlet (regulates for variable pressures) * Mechanism to fill the storage with safety controllers and monitor the filling pressure of the individual storage cylinders INo. Mini Airgun (60 cu.in) INo. Sercel mini GI GUN -- Propriety Item (60 cu.in)/(30/30 with 15/15 volume reducer) with 1x volume reducer Generator 15 cu. in. + 1 spare 1 x injector 15 cu.in + 1 spare 1 x Discharge port Small + 1 spare No. Marine Source on board 3) 1 x Seismic source controller capable of firing and synchronizing up to 2 Mini airguns with 5 msec resolution as standalone unit; Firing should be triggered by an internal clock or an external signal through BNC connector; Source signal recording 1 x Dispatch Panels for Mini Airgun; b) 1.x Seismic source controller capable of firing and synchronizing up to 2 Mini GLGUN with 5 msec resolution as standalone unit; Firing should be triggered by an internal clock or an external signal through BNC connector; Source signal recording 1 x Dispatch Panels for Sercel Mini GI Gun; INo. Tx Lubrication Pump 2.x Distributer Valves Important Note: The vendor should evaluate the possibility of using a single firing controller for both Mini Airgun and Mini GI Gun; only one the guns will be operated at a time. Spare Parts, INo. 1x Spare Kit for Mini Airgun firing Controller, Gun Ancillary equipment Kit, Mini Airgun Hardware Kit; Mini Airgun Special Tooling; Mini Airgun ‘TB Hydrophone assembly; Mini Airgun maintenance Kit; Mini Airgun Solenoid Maintenance Kit 1 x Spare Kit for Mini GI Gun firing Controller; Gun Ancillary equipment Kit; Mini GI Gun Hardware Kit; Mini GI.Gun Special Tooling; Mini GI Gun TB hydrophone assembly; Mini GI Gun maintenance kit; Mini GI Gun Solenoid Maintenance Kit Mai Source in Sea 1No. 1 x 210ft Terminated air and electrical lines for Mini Airgun Gun 1 x 210ft Terminated air and electrical lines for Sercel GI Gun. 1x Gun hanger for 1 airgun (mini Airgun or Mini GI Gun); 2x Ancillary Equipment; 2x Depth Rope; 1x Float Buoy; 1 x Net for Buoy Training Onboard NIO’s Research Vessel 1No. 1 week of Supervision of Marine Source Equipment ~ Installation; 1 week of Supervision of Marine Source Equipment - Start Up; Manuals; Training; Travel Expenses, including Living Expenses ‘Terms and conditions 1. The vendor/integrator should take the responsibility of procuring the individual items and assemble them as one source unit. 2. ‘The vendor/integrator should undertake field testing of continuous operation for at least 48 hrs @ 8s firing interval of mini GI gun and @ 16s firing of mini airgun. 3. The vendor should have carried out similar integration in the past (docementary evidence need to be furnished). 4. The bidder must submit point to point response to each technical specification. 5. Integration of source and existing streamer and recording unit (Mini Trace II), and testing the complete system for continuous data recoding during trial and testing. Details of the recording equipment are found in the following link: hitp://www.geomarinesurveysystems.com/products/data-aquisition. 6. The vendor may evaluate the possibility of using a single firing controller for both Mini Airgun and Mini GI Gun; only one of the guns will be operated at a time. The detailed procedure need to be provided for onboard configuration of source control unit for wit . switching between the guns. faces 7. The vendor should provide the quotes for annual maintenance (AMC) whick may be included as optional item. composer wr tage

Você também pode gostar