Você está na página 1de 1

250x200

See Drawing No. 3350-L57-100-2 for Continuation

400x250
EAD, 345 L/s

RAMP 1 in 21.4

RAMP 1 in 21.4

14850

STORE
1

250x200
FAD, 160 L/s

250x200
EAD, 144 L/s

7690

BG-038

10 11 12 13 14 15 16 17 18 19

1.
2.

BG-039
7200

G01 - CLASSROOM 07

BG-038

BG-020

G01 - CLASSROOM 08

7200

OUTDOOR PLAY AREA

7500

GENERAL NOTES

VCD

STAIR B05
7500

7690

3.

BG-021

4.

VCD

5.

VCD

250x200
FAD, 160 L/s
450x400
TED T/A
F

2480

250x200 7200
EAD, 144 L/s

6000

6000

250x250

300x250

250x200
FAD, 160 L/s

VCD

450x300

550x350

250x200
FAD, 160 L/s

6225

500x300

450x300

BG-030

KS1 LIBRARY

VCD

BG-015

750x400

750x450

950x500

750x450

ICT BASES

BG-013

VCD

VCD2150

150x150
FAD, 47 L/s

BG-014

600x350

RISER
650x400

700x400

800x400

800x450

850x450

350x250
VCD

250x200
FAD, 160 L/s

250x150
200x100

ICT BASES

800x450

250x150
FAD, 105 L/s

250x200
FAD, 160 L/s

7690

950x450
STAIR B02

300x250

200x150

4740
200x150
FAD, 72 L/s

VCD

250x200

600x400

BG-003A

200x150
EAD, 66 L/s
250x200
FAD, 160 L/s

BG-029

250x200
FAD, 160 L/s
250x150
EAD, 85 L/s

14475
250x150
EAD, 95 L/s
350x300

7200

VCD

VCD

CORRIDOR

800x450

250x200
EAD, 144 L/s

250x200 7200
EAD, 144 L/s

200x150
EAD, 66 L/s

FAD, 160 L/s

200x150
EAD, 62 L/s

250x200
EAD, 144 L/s

7200

200x150
EAD, 67 L/s

500x350

250x200
FAD, 160 L/s

SSL +0.405

BG-019

CO2 SENSOR

7200

ROAD LVL +7.45M

250x200
EAD, 144 L/s
G02 - CLASSROOM 08

10515

3450

FD

VCD

VCD

250x200
FAD, 160 L/s

250x200
FAD, 160 L/s

VCD

VCD
250x200
FAD, 160 L/s

250x200
FAD, 160 L/s

250x200
FAD, 160 L/s

FFL +8.40M
250x200
FAD, 160 L/s

FFL +8.38M
LOBBY
BG-031
300x150
250x150

VCD

1.

350x300
G-0-16

LOBBY
BG-003

200x150
FAD, 76 L/s

7200
250x200
EAD, 144 L/s

7200
250x200
EAD, 144 L/s

VCD

VCD

7200
250x200
EAD, 144 L/s

200x150
FAD, 76 L/s

250x2007200
EAD, 144 L/s

VCD

7200
250x200
EAD, 144 L/s

200x150
FAD, 76 L/s

A-0-14

VCD

VCD

250x2007200
EAD, 144 L/s

BG-002

G-0-14
CLNR-T04

DIS WC-T04

LOBBY

BG-033

BG-034

BG-032

G-0-14

BG-024

BG-025

G02 - CLASSROOM 05

G02 - CLASSROOM 06

BG-026

BG-027

7690

BG-023

G02 - CLASSROOM 04

7690

BG-022

G02 - CLASSROOM 03

7690

G02 - CLASSROOM 02

7690

7690

3535

G02 - CLASSROOM 01

150
150

G02 - CLASSROOM 07 350x300


BG-028

FINISH FLOOR LEVEL +0.480 = F.F.L. +8.40 ON SITE


REVISIONS
No. DATE

DESCRIPTION

C0

CONSTRUCTION ISSUE

15-06-15

BY
DA

DESIGN ARCHITECTS & MEP ENGINEERS

BG-035

BG-001

RE EXAM STORE

ZONE-B

150
100
M WC - T01

A-0-15

STAIR B01

ZONE-A

A-0-14

300x150

SECURITY

100x100
FAD, 5 L/s
FFL. + 8.40M
150x100

CLNR-T06

250x2007200
EAD, 144 L/s

7690

150x100

VCD

7690

A-0-42
(TYP. 2Nos.)

VCD

BG-004

VCD VCD

2875

7000

7000

WC-T05

See Drawing No.


3350-L57-100-7 for Continuation
150

100x100
FAD, 10 L/s
250x200
EAD, 144 L/s

250x200
EAD, 144 L/s

1000x450

100x100
FAD, 15 L/s

7200

450x300

BG-012

KEY PLAN

950x500

RISER

7200

3960

G01 - CLASSROOM 06

BG-011

400x250

LOBBY

1330

G01 - CLASSROOM 05

BG-010

7990

G01 - CLASSROOM 04

BG-009

7990

BG-008

7990

G01 - CLASSROOM 03
7990

7990

7500

G01 - CLASSROOM 02

7365

BG-007

7500

SUPPORT ROOM

BG-006

7.

UP

See Drawing No. 3350-L57-100-4 for Continuation

BG-016

FD

1985

IDF ROOM
ELEC ROOM
950x500 FAD F/ABG-017
BG-018 550x700 EAD T/A
FD
FAHU-P1R02

SMDB-0-03

LOBBY

G01 - CLASSROOM 01

2830
2480

2930

100x100
EAD, 08 L/s

100x100
EAD, 13 L/s

6.

250x200
EAD, 144 L/s
150x150
FAD, 48 L/s

This Drawing is not to be scaled.


All dimensions shown are in millimeters and do not take into
account applied finishes unless specifically indicated otherwise.
Any omissions or discrepancies found shall be reported to the
Architect / Engineer immediately.
Levels are given in meters to three decimal places above survey
datum.
This drawing is to be read in conjunction with the relevant section
of the specification and schedules.
The contractor shall submit full shop / setting out drawing for
approval (based on site dimensions) prior to commencement of
any site works, placing of orders, manufacture of fittings, fixtures
and components.
For External Finishes refer to Landscape Drawings and
Specifications.

Godwin Austen Johnson


Architects

G-0-14
(TYP. 7Nos.)

UP

250x150

STRUCTURAL ENGINEERS

7200

FFL +8.38M
7200

LOBBY
BG-036

2.

SHADED PLAY AREA

1.

A-0-15

BG-038
140

300
200

250
200

200 200 150


200 150 150

150
100

F WC - T01
G-0-15
(TYP. 7Nos.) BG-037

280

MOVEMENT JOINT

KS1 / ADMIN ENT


B

PRIMARY /
ADMIN
ENTRANCE

OWNER

FORTES HOLDING

FFL +8.18M

ISSUED FOR
9800

9800

CONSTRUCTION
PROJECT

JVT SCHOOL
Plot No. JVT05SCP001
Jumeirah Village Triangle, Dubai, UAE
DRAWING TITLE

MECHANICAL SERVICES
GROUND FLOOR PLAN, PART-1
VENTILATION LAYOUT

A
ROAD LVL +7.52M

Drawn
Date
Project No.

FA Checked
08.06.2014 Scale
Zone

3350
Authority Dwg. No.

EL Approved

OP

1:100 @ A1

Drawing No.

L57-100-1

Rev.

C0
Consecutive No.

This drawing, the designs and details shown are the copyright of
GODWIN AUSTEN JOHNSON and shall not be copied or reproduced in
any form without their written consent.

13

A1

14

15

Original Sheet FILE PATH : F:\- PROJECTS CURRENT\3350 - Fortes School\LIVE\ACAD\MEP DEPT\Sheet Files\Mechanical\57-Ventilation\3350-L57-100-1.dwg
Size

16

17

18

19

20

21

22

23

T +971 4 3237555 E mail@gaj-uae.ae


F +971 4 3237717 W www.gaj-uae.ae
PO Box 7185 Dubai United Arab Emirates