Eccentric Footing Load & Moment Calculation(End Frame)

End Frame Reaction (From Steel Frame Structure)


Dead Load

6.918

kN

Collateral Load

2.61

kN

Roof Live Load

6.264

kN

Lateral Load (positive)

1.35

kN

Lateral Load(Negative)

1.35

kN

X Direction

Y Direction
Left Side (Wind)
WL1

10.912

WL2

7.312

kN

Right Side(Wind)
WR1
4.168

kN

kN

WR2

kN

0.568

Wall Load Calculation


Wall thickness

200

mm

c/c Distance between the wall

Height of Wall

Wall Finish Thickness

20

mm

Unit weight of block

16

kN/m3

Unit weigt of plain concrete

20

kN/m3

Total Wall Load

43.2

kN

Load Combination
SERVICE LOAD COMBINATION (FOOTING DESIGN )
1
2
3
4
5
6
7
8

1DL+1LL
1DL+1LL+1WX
1DL+1LL-1WX
1DL+1LL+1WY
1DL+1LL-1WY
1DL+1LL+0.714EQX
1DL+1LL-0.714EQX
1DL+1LL+0.714EQY
Load (P)

58.992
77.216
40.768
63.728
54.256
59.9559
58.0281
59.9559

kN
kN
kN
kN
kN
kN
kN
kN

77.216

kN

Ultimate Load (1.5*P)

115.824

kN

Eccentricity (e)

120

mm

Moment

P*e

13.89888

kN.m

Load &Moment is less than the Middle frame.So we take middle frame load as critical case.