Você está na página 1de 1

Date : 3-10-2013

Calculation Sheet
Affinity Laws for centrifugal pumps
Project : L&T TC3
Contractor - Suvidha
Consultant - WSP

ApplicationModelPower Flow in CMH Head in Mtr Power BKWSr. No.


1
2
3
4
5
6
7
8
9
10
11
12
13

Primary Pump
NB80-250/270 A-F-B-BAQE

11 KW
90
23
7.2
Speed in %
100%
90%
80%
75%
70%
60%
50%
40%
30%
25%
20%
10%
0%

Flow in CMH
90
81
72
68
63
54
45
36
27
23
18
9
0

Head In %
100%
81%
64%
64%
49%
36%
25%
16%
9%
9%
4%
1%
0%

Head in Mtr
23.0
18.6
14.7
14.7
11.3
8.3
5.8
3.7
2.1
2.1
0.9
0.2
0.0

Note -

1
2

Please enter the data in YELLOW -

All other values will change accordingly.

Cells only

BKW in %
100%
73%
51%
51%
34%
22%
13%
6%
3%
3%
0.8%
0.1%
0%

BKW
7.20
5.26
3.67
3.67
2.45
1.58
0.94
0.43
0.22
0.22
0.06
0.01
0.00