Escolar Documentos
Profissional Documentos
Cultura Documentos
November 2006
P/N 300−000−166
ECO 51611 Rev B65
EMC Support Matrix
Copyright EMC Corporation 2006...................................................................................................................................................................................................1
EMC's Policies and Requirements for EMC Support Matrix.........................................................................................................................................................2
End−of−Support Products.................................................................................................................................................................................................2
General Information for AX100........................................................................................................................................................................................................5
Configuration Rules: AX100 Storage Systems.................................................................................................................................................................5
Backup Device Support.....................................................................................................................................................................................................5
Path Definition...................................................................................................................................................................................................................5
AX Series EMC Partner Solutions.....................................................................................................................................................................................5
CLARiiON AX100..............................................................................................................................................................................................................................6
Base Connectivity.............................................................................................................................................................................................................6
Fujitsu Siemens Solaris...................................................................................................................................................................................6
Fujitsu Solaris..................................................................................................................................................................................................6
Haansoft Asianux Server 2.0 [32−Bit]..............................................................................................................................................................7
Haansoft Asianux Server 2.0 [AMD64]............................................................................................................................................................7
Haansoft Asianux Server 2.0 [EM64T]............................................................................................................................................................8
Microsoft Windows 2000..................................................................................................................................................................................9
Microsoft Windows 2003 [x64].......................................................................................................................................................................21
Microsoft Windows 2003 [x86].......................................................................................................................................................................33
MiracleLinux MLSE [32−Bit]..........................................................................................................................................................................62
MiracleLinux MLSE [AMD64].........................................................................................................................................................................62
MiracleLinux MLSE [EM64T].........................................................................................................................................................................63
Novell Netware..............................................................................................................................................................................................64
Oracle Enterprise Linux [32−Bit]....................................................................................................................................................................66
Oracle Enterprise Linux [AMD−64]................................................................................................................................................................71
Oracle Enterprise Linux [EM64T]...................................................................................................................................................................73
Red Flag DC Server [32−Bit].........................................................................................................................................................................76
Red Flag DC Server [AMD64].......................................................................................................................................................................77
Red Flag DC Server [EM64T]........................................................................................................................................................................78
Red Hat RHEL [32−Bit]..................................................................................................................................................................................78
Red Hat RHEL [AMD−64]............................................................................................................................................................................120
Red Hat RHEL [EM64T]..............................................................................................................................................................................125
SuSE SLES [32−Bit]....................................................................................................................................................................................148
SuSE SLES [AMD−64]................................................................................................................................................................................170
SuSE SLES [EM64T]...................................................................................................................................................................................172
SuSE SLES [x86_64]...................................................................................................................................................................................179
Sun Solaris..................................................................................................................................................................................................182
VMware ESX Server....................................................................................................................................................................................184
Cluster Software............................................................................................................................................................................................................194
Microsoft Windows 2000..............................................................................................................................................................................194
Microsoft Windows 2003 [x64].....................................................................................................................................................................194
Microsoft Windows 2003 [x86].....................................................................................................................................................................194
Red Hat RHEL [32−Bit]................................................................................................................................................................................194
Red Hat RHEL [EM64T]..............................................................................................................................................................................195
Red Hat RHEL [IA64]...................................................................................................................................................................................195
Fibre Connectivity: Switch.............................................................................................................................................................................................195
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................195
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................196
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................196
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................196
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................196
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................197
Microsoft Windows 2000..............................................................................................................................................................................197
Microsoft Windows 2003 [x64].....................................................................................................................................................................198
Microsoft Windows 2003 [x86].....................................................................................................................................................................200
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................202
MiracleLinux MLSE [AMD64].......................................................................................................................................................................202
MiracleLinux MLSE [EM64T].......................................................................................................................................................................202
Novell Netware............................................................................................................................................................................................203
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................203
Oracle Enterprise Linux [EM64T].................................................................................................................................................................203
Red Flag DC Server [32−Bit].......................................................................................................................................................................204
Red Flag DC Server [AMD64].....................................................................................................................................................................204
Red Flag DC Server [EM64T]......................................................................................................................................................................204
Red Hat RHEL [32−Bit]................................................................................................................................................................................205
Red Hat RHEL [AMD−64]............................................................................................................................................................................206
Red Hat RHEL [EM64T]..............................................................................................................................................................................207
Red Hat RHEL [IA64]...................................................................................................................................................................................208
SuSE SLES [32−Bit]....................................................................................................................................................................................208
SuSE SLES [AMD−64]................................................................................................................................................................................209
SuSE SLES [EM64T]...................................................................................................................................................................................210
SuSE SLES [IA64].......................................................................................................................................................................................211
SuSE SLES [x86_64]...................................................................................................................................................................................211
Sun Solaris..................................................................................................................................................................................................212
Sun Solaris x86............................................................................................................................................................................................212
VMware ESX Server....................................................................................................................................................................................212
General Information for AX150....................................................................................................................................................................................................214
Configuration Rules: AX150 Storage Systems.............................................................................................................................................................214
Backup Device Support.................................................................................................................................................................................................214
Path Definition...............................................................................................................................................................................................................214
Remote Replication.......................................................................................................................................................................................................214
AX100i Rules.................................................................................................................................................................................................................................397
Switches, Routers, Network Interface Cards (NICs), and iSCSI Host Bus Adapters (HBAs) ......................................................................................397
Environments and Configurability ................................................................................................................................................................................397
Considerations .............................................................................................................................................................................................................397
CLARiiON AX100i.........................................................................................................................................................................................................................398
Native iSCSI..................................................................................................................................................................................................................398
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................398
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................398
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................398
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................399
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................399
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................399
Microsoft Windows 2000..............................................................................................................................................................................399
Microsoft Windows 2003 [x64].....................................................................................................................................................................400
Microsoft Windows 2003 [x86].....................................................................................................................................................................401
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................401
MiracleLinux MLSE [AMD64].......................................................................................................................................................................402
MiracleLinux MLSE [EM64T].......................................................................................................................................................................402
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................403
Oracle Enterprise Linux [AMD−64]..............................................................................................................................................................403
Oracle Enterprise Linux [EM64T].................................................................................................................................................................404
Red Flag DC Server [32−Bit].......................................................................................................................................................................404
Red Flag DC Server [AMD64].....................................................................................................................................................................405
Red Flag DC Server [EM64T]......................................................................................................................................................................405
Red Hat RHEL [32−Bit]................................................................................................................................................................................406
Red Hat RHEL [AMD−64]............................................................................................................................................................................407
Red Hat RHEL [EM64T]..............................................................................................................................................................................408
SuSE SLES [32−Bit]....................................................................................................................................................................................409
SuSE SLES [AMD−64]................................................................................................................................................................................410
SuSE SLES [EM64T]...................................................................................................................................................................................410
SuSE SLES [IA64].......................................................................................................................................................................................411
SuSE SLES [x86_64]...................................................................................................................................................................................411
VMware ESX Server....................................................................................................................................................................................411
iSCSI Clusters...............................................................................................................................................................................................................411
Microsoft Windows 2003 [x64].....................................................................................................................................................................411
Microsoft Windows 2003 [x86].....................................................................................................................................................................412
AX150i Rules.................................................................................................................................................................................................................................413
Configuration Rules: AX150i Storage Systems.............................................................................................................................................................413
Switches, Routers, NICs...............................................................................................................................................................................................413
Environment and Configurability...................................................................................................................................................................................413
Considerations..............................................................................................................................................................................................................413
EMC Support Matrix
CLARiiON AX150i.........................................................................................................................................................................................................................414
Native iSCSI..................................................................................................................................................................................................................414
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................414
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................414
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................414
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................415
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................415
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................415
IBM AIX........................................................................................................................................................................................................415
Microsoft Windows 2000..............................................................................................................................................................................416
Microsoft Windows 2003 [x64].....................................................................................................................................................................416
Microsoft Windows 2003 [x86].....................................................................................................................................................................417
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................417
MiracleLinux MLSE [AMD64].......................................................................................................................................................................418
MiracleLinux MLSE [EM64T].......................................................................................................................................................................419
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................419
Oracle Enterprise Linux [AMD−64]..............................................................................................................................................................419
Oracle Enterprise Linux [EM64T].................................................................................................................................................................420
Red Flag DC Server [32−Bit].......................................................................................................................................................................420
Red Flag DC Server [AMD64].....................................................................................................................................................................421
Red Flag DC Server [EM64T]......................................................................................................................................................................421
Red Hat RHEL [32−Bit]................................................................................................................................................................................422
Red Hat RHEL [AMD−64]............................................................................................................................................................................423
Red Hat RHEL [EM64T]..............................................................................................................................................................................424
SuSE SLES [32−Bit]....................................................................................................................................................................................425
SuSE SLES [AMD−64]................................................................................................................................................................................425
SuSE SLES [EM64T]...................................................................................................................................................................................426
SuSE SLES [IA64].......................................................................................................................................................................................426
SuSE SLES [x86_64]...................................................................................................................................................................................427
iSCSI Clusters...............................................................................................................................................................................................................427
Microsoft Windows 2003 [x64].....................................................................................................................................................................427
Microsoft Windows 2003 [x86].....................................................................................................................................................................427
EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS". EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY
KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.
Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.
Trademark Information
EMC2, EMC, EMC ControlCenter, AlphaStor, ApplicationXtender, Captiva, Catalog Solution, Celerra, CentraStar, CLARalert, CLARiiON, ClientPak, Connectrix,
Co−StandbyServer, Dantz, Direct Matrix Architecture, DiskXtender, DiskXtender 2000, Documentum, EmailXaminer, EmailXtender, EmailXtract, eRoom,
FLARE, HighRoad, InputAccel, Navisphere, nLayers, OpenScale, PowerPath, Rainfinity, RepliStor, ResourcePak, Retrospect, Smarts, SnapShotServer,
SnapView/IP, SRDF, Symmetrix, TimeFinder, VisualSAN, VSAM−Assist, WebXtender, where information lives, Xtender, and Xtender Solutions are registered
trademarks and EMC Developers Program, EMC OnCourse, EMC Proven, EMC Snap, EMC Storage Administrator, Acartus, Access Logix, ArchiveXtender,
Authentic Problems, Automated Resource Manager, AutoStart, AutoSwap, AVALONidm, C−Clip, Celerra Replicator, Centera, CLARevent, Codebook
Correlation Technology, Common Information Model, CopyCross, CopyPoint, DatabaseXtender, Direct Matrix, EDM, E−Lab, Enginuity, FarPoint, Global File
Virtualization, Graphic Visualization, InfoMover, Infoscape, Invista, MediaStor, MirrorView, NetWin, NetWorker, OnAlert, Powerlink, PowerSnap, RecoverPoint,
RepliCare, SafeLine, SAN Advisor, SAN Copy, SAN Manager, SDMS, SnapImage, SnapSure, SnapView, StorageScope, SupportMate, SymmAPI,
SymmEnabler, Symmetrix DMX, UltraPoint, UltraScale, Viewlets, and VisualSRM are trademarks of EMC Corporation. All other trademarks used herein are the
property of their respective owners.
This section describes EMC's policies and requirements for the EMC Support Matrix document.
This document is being provided for informational purposes only and may change at any time. This version supersedes and replaces all previous versions. The
information is to serve only as a guide for those configurations/products which EMC has qualified. The information in this document is a subset of the
information that can be found on the E−Lab Navigator tool which is available for all EMC personnel, customers and partners. The E−Lab Navigator site may be
reached at http://elabnavigator.emc.com.
The information included in this document is intended as a guide in the configuration of systems for EMC's products. It is not intended to be the sole resource
for system configuration. For more information or answers to questions not found in this document, please see EMC's website, other EMC documentation, such
as EMC's Host Connectivity Guides, EMC Networked Storage Topology Guide, EMC CLARiiON Open Systems Configuration Guide, relevant vendor
documentation, or contact your EMC Sales or EMC Customer Service representative.
For Symmetrix 4.x support, please look at the Symmetrix 8000 Series section and check the footnotes for model/microcode compatibility. EMC employees can
obtain older revisions of ESM containing more Symmetrix 4.x information from the Symmetrix Service Readiness group.
For a complete listing of any known issues with the current support matrix content, please review the ESM Errata on E−Lab Navigator. To report any issues with
the content contained within the support matrix, follow the steps documented on the Contacts link on E−Lab Navigator. E−Lab Navigator can be reached at
http://elabnavigator.emc.com.
Policies and procedures for support of EMC products are set forth in the customer's applicable agreements. EMC's publication of information relating to system
configurations covers only those outlined in this document or by approval from EMC Engineering. Other system configurations not found in this document are
not qualified without EMC Engineering approval. EMC has qualified hardware and software provided only by the vendors listed in this document, and host
systems, hardware and software from other vendors are not qualified, and may never be. Please contact your EMC Sales or EMC Customer Service
representative for updates or information not included in this document.
EMC maintains a large collection of the products listed above as well as third−party application software for qualification with EMC's storage systems and to
simulate customer environments, but you must consult the vendors for information about their system internals, such as hardware and associated drivers.
The information in this document is maintained by EMC and EMC strives to update this document with new releases of hardware, operating systems, firmware,
BIOS, switch software, etc., as they become available from the vendors. EMC works with the vendors during their development and release processes in order
to be fully informed at the time the vendors release new versions. EMC does not announce qualification prior to vendors' General Availability. In some cases,
EMC may choose to perform regression testing following the vendors' GA; in these cases and in cases where advance preparation is not possible, EMC may
validate and qualify vendors' products as appropriate after they have been released. For early support of such products, including vendor beta participation,
contact your EMC Sales or EMC Customer Service representative.
EMC strives to continue support for any installed platforms, but may remove support from this host matrix for new installations within three months after the
vendor has announced that this platform has reached the end of life. EMC will continue support for existing installations of hardware, operating systems, and
components that the vendor has officially declared to have reached end of life as long as support is available from the vendor.
End−of−Support Products
End−of−Support
No. Component Name Date Description
1 05/30/200614 End of support
4/30/06
2 Caldera UNIXWare 7.0.1, Caldera UNIXWare 7.1.1, DG DG/UX R4.11MU03, DG DG/UX R4.20MU06, DG DG/UX 05/15/20067 Discontinuity
R4.20MU07 support for
this
environment in
the June
publication.
3 Egenera BladeFrame SW 4.0, Fujitsu Siemens Primergy BladeFrame SW 4.0 08/22/200617 PAN Manager
4.0.0 release
is officially
retired by
Egenera.
Egenera
support policy
specifies that
only the latest
version within
a major
release family
is supported.
End−of−Support
No. Component Name Date Description
4 EMC PowerPath (PPVM) 4.0, EMC PowerPath (PPVM) 4.1 03/15/20066 This version of
EMC
Powerpath is
scheduled to
reach EOSL
March 30,
2006.
5 EMC PowerPath 2.0.0, EMC PowerPath 2.0.1, EMC PowerPath 2.0.2, EMC PowerPath 2.0.3, EMC PowerPath 2.0.4, 05/10/20069 This release of
EMC PowerPath 2.1.0, EMC PowerPath 2.1.1, EMC PowerPath 2.1.2, EMC PowerPath 2.1.3, EMC PowerPath 3.0.0, PowerPath
EMC PowerPath 3.0.1, EMC PowerPath 3.0.2, EMC PowerPath 3.0.2 b069, EMC PowerPath 3.0.2 b41, EMC PowerPath has reached
3.0.3 b 00310, EMC PowerPath 3.0.3 b065, EMC PowerPath 3.0.4 b012, EMC PowerPath 3.0.4.2, EMC PowerPath 3.0.5 the end of it's
b032, EMC PowerPath 3.0.6, EMC PowerPath 3.0.6 b010, EMC PowerPath 3.0.7, EMC PowerPath 3.0.7 b007, EMC service life
PowerPath 4.0.0, EMC PowerPath 4.0.1, EMC PowerPath 4.0.2 and is no
longer
supported.
6 EMC PowerPath 3.0.3 03/30/20066 This version of
EMC
Powerpath is
scheduled to
reach EOSL
March 30,
2006.
7 EMC PowerPath 4.0.3, EMC PowerPath 4.1, EMC PowerPath 4.2 06/30/200611 This release of
PowerPath will
reach end of
it's service life
on 6/30/2006
at which point
it will no
longer be
supported.
8 FCS Solaris 2.6, Fujitsu Siemens Solaris 2.6, Fujitsu Solaris 2.6 07/31/200613 Solaris 2.6
went End Of
Life by Sun in
February
2001. These
configurations
will be
removed from
the ESM
starting in
September
2006.
9 HPQ HP 9000 D370, HPQ HP 9000 D380 11/16/200616 support will be
removed from
the EMC
support matrix
as of
December
2006.
10 HPQ HP 9000 D390 04/14/200715 support will be
removed from
the EMC
support matrix
as of May
2007.
11 HPQ HP 9000 R380, HPQ MC/Service Guard 11.14, HPQ MC/Service Guard 11.15, NEC NX7000 27, NEC NX7000 37, 11/19/200616 support will be
NEC NX7000 D280, NEC NX7000 D380, NEC TX7 D280 removed from
the EMC
support matrix
as of
December
2006.
12 HPQ HP 9000 R390 11/16/299615 support will be
removed from
the EMC
support matrix
as of May
2007.
13 HPQ HP 9000 rp2450 11/19/200618 HP−UX
Rp2450
support will be
removed from
the EMC
support matrix
as of
December
2006.
14 HPQ HP−UX 11.0 11/19/200621 HP−UX 11.00
support will be
removed from
the EMC
support matrix
as of
December
2006.
15 HPQ MPE/ix 5.0, HPQ MPE/ix 5.5, HPQ MPE/ix 6.0, HPQ MPE/ix 6.5, HPQ MPE/ix 6.5.02, HPQ MPE/ix 7.0.01, HPQ 11/19/20064 MPE support
MPE/ix 7.520 will be
removed from
the EMC
support matrix
as of
December
2006.
16 IBM z/OS 1.4 03/31/20072 IBM plans to
discontinue
service for this
version of
z/OS on
03/31/2007.
End−of−Support
No. Component Name Date Description
17 IBM z/OS 1.4, IBM z/OS 1.5, IBM z/OS.e 1.4, IBM z/OS.e 1.5 03/31/20071 To be
discontinued
18 NEC NX7000 D390, NEC TX7 D390 04/15/200715 support will be
removed from
the EMC
support matrix
as of May
2007.
19 NEC NX7000 rp2450, NEC TX7 rp2450 11/19/200619 NEC rp2450
support will be
removed from
the EMC
support matrix
as of
December
2006.
20 Novell Netware 5.00 SP4, Novell Netware 5.00 SP6A, Novell Netware 5.10, Novell Netware 5.10 SP2, Novell Netware 5.10 05/01/20065 Discontinuing
SP2A, Novell Netware 5.10 SP3, Novell Netware 5.10 SP4, Novell Netware 5.10 SP5, Novell Netware 5.10 SP6, Novell support for
Netware 5.10 SP7, Novell Netware 6.0 SP1, Novell Netware 6.0 SP2, Novell Netware 6.0 SP3, Novell Netware 6.0 SP4, Novell
Novell Netware 6.0 SP5 Netware
EOSL Product
21 Red Hat RHEL [32−Bit] 2.1 U2 v2.4.9−e.24, Red Hat RHEL [32−Bit] 2.1 U2+ v2.4.9−e.25, Red Hat RHEL [32−Bit] 2.1 U2+ 06/25/200612 To align with
v2.4.9−e.27, Red Hat RHEL [32−Bit] 2.1 U3 AS/ES v2.4.9−e.35, Red Hat RHEL [32−Bit] 2.1 U3+ AS/ES v2.4.9−e.38, Red EMC Software
Hat RHEL [32−Bit] 2.1 U4 AS/ES v2.4.9−e.40, Red Hat RHEL [32−Bit] 2.1 U4+ AS/ES v2.4.9−e.43, Red Hat RHEL Support, this
[32−Bit] 2.1 U5 AS/ES v2.4.9−e.49, Red Hat RHEL [32−Bit] 2.1 U6 AS/ES v2.4.9−e.57, Red Hat RHEL [32−Bit] 2.1 U6+ product is
AS/ES v2.4.9−e.59, Red Hat RHEL [32−Bit] 2.1 U7 AS/ES v2.4.9−e.62, Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.41, marked EOSL.
Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.43, Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.47, Red Hat RHEL [IA64] 2.1
AS/ES v2.4.18−e.52, Red Hat RHEL [IA64] 2.1 U7 AS/ES v2.4.18−e.56
22 Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.31 09/30/20058 EOS RHEL
2.1 [IA64]
v2.4.18−e.31
− see footnote
38398
23 Sun Solaris 2.6 05/10/20063 Sun Solaris
2.6 will be End
of Support as
of June 2006.
1. To be discontinued
2. IBM plans to discontinue service for this version of z/OS on 03/31/2007.
3. Sun Solaris 2.6 will be End of Support as of June 2006.
4. MPE support will be removed from the EMC support matrix as of December 2006.
5. Discontinuing support for Novell Netware EOSL Product
6. This version of EMC Powerpath is scheduled to reach EOSL March 30, 2006.
7. Discontinuity support for this environment in the June publication.
8. EOS RHEL 2.1 [IA64] v2.4.18−e.31 − see footnote 38398
9. This release of PowerPath has reached the end of it's service life and is no longer supported.
10. Supported with HP−UX 11.0, 11i only − HP−UX 10.20 supported dropped with this version.
11. This release of PowerPath will reach end of it's service life on 6/30/2006 at which point it will no longer be supported.
12. To align with EMC Software Support, this product is marked EOSL.
13. Solaris 2.6 went End Of Life by Sun in February 2001. These configurations will be removed from the ESM starting in September 2006.
14. End of support 4/30/06
15. support will be removed from the EMC support matrix as of May 2007.
16. support will be removed from the EMC support matrix as of December 2006.
17. PAN Manager 4.0.0 release is officially retired by Egenera. Egenera support policy specifies that only the latest version within a major release family is supported.
18. HP−UX Rp2450 support will be removed from the EMC support matrix as of December 2006.
19. NEC rp2450 support will be removed from the EMC support matrix as of December 2006.
20. Requires Symmetrix microcode:
5266.40.28 or higher
5566.40.27 or higher
5267.25.17 or higher
5567.32.16 or higher
5568.34.14 or higher
21. HP−UX 11.00 support will be removed from the EMC support matrix as of December 2006.
For tape devices connected directly to a backup host, EMC strongly recommends that the component vendors' supported configuration matrices are reviewed
(host configuration matrix for compatibility with SCSI or Fibre Channel interface used to connect to tape device, tape device vendor for compatibility with
selected SCSI or Fibre Channel interface and backup software vendor for compatibility with the tape device).
Path Definition
A path is a connection between an HBA port and a target an SP port in a storage system. Each HBA that is directly connect to, or zoned through, a switch to an
SP port is considered an initiator of that SP port. An HBA port can be zoned through different switch ports to the same SP port or to different SP ports, resulting
in multiple paths between the HBA port and an SP.
http://www.emc.com/partnersalliances/partners/sp.jsp
For general information about the EMC AX Series Storage System, please follow the link below:
http://www.emc.com/products/systems/clariion/ax150/index.jsp
2 Fujitsu Siemens Fujitsu PCI Fujitsu Siemens: LP10000−E (GP70F−CF33)1, 2, 3, 4, 5, 6, 7, 8, 14, 16, 17, 18, 19 , FC−AL, EMC N
PRIMEPOWER: 200, 250, Siemens LP11000−E (GP70F−CF36)3, 5, 6, 16, 17, 18, 19, 21 , LP9802−E (GP70F−CF31)1, 2, 3, 4, 5, FC−SW CLARiiON
400, 450, 600, 650, 850 Solaris: 8, 9 6, 7, 8, 14, 16, 17, 18, 19 AX10020
1. Driver Version 6.02f
2. Firmware Version 1.91a1
3. FCode Value 1.41a4
4. Driver Version 6.02hx2
5. SNIA HBA API Supported.
6. FCode Value 1.50a4
7. Firmware Version 1.90a4
8. Driver Version 6.02e
9. The SAN driver is part of the OS.
10. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
11. FSC requires all patches for Solaris 10 be obtained through FSC in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers running
Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
12. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
13. Firmware Version 3.92a3
14. Driver Version 6.01f
15. Driver Version 5.01e
16. Driver Version SAN 4.4.7a
17. Driver Version SAN 4.4.10
18. Driver Version SAN 4.4.8
19. Driver Version SAN 4.4.9
20. AX100 requires the following minimum Flare revs:
AX100 02.16.102.5.004
AX100SC 02.16.101.5.004
21. Firmware Version 2.10a9
Fujitsu Solaris
Fujitsu Solaris
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot Comments
1 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex: LP10000−E9, 13, 14, 15, 16, 17, 18, 19, 22, 23 , FC−AL, EMC Y See3
2500, 450, 650, 850, 900 1020, 21 LP9802−E9, 13, 14, 15, 16, 17, 18, 19, 22 FC−SW CLARiiON
AX1004
2 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC224, PW008FC324 FC−AL, EMC N See3
2500, 450, 650, 850, 900 1020, 21 FC−SW CLARiiON
AX1004
3 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex LP9802−E9, 10, 11, 12, 13, 14, 15, 16, 17, 18 FC−AL, EMC Y See3
2500, 450, 650, 850, 900 8 02/027 FC−SW CLARiiON
AX1004
4 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC21, 2, 5, 6, PW008FC31, 2, 5, 6 FC−AL, EMC N See3
2500, 450, 650, 850, 900 8 02/027 FC−SW CLARiiON
AX1004
5 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex LP9802−E9, 10, 11, 12, 13, 14, 15, 16, 17, 18 FC−AL, EMC Y See3
2500, 450, 900 9 04/038 FC−SW CLARiiON
AX1004
6 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC21, 2, 5, 6, PW008FC31, 2, 5, 6 FC−AL, EMC N See3
2500, 450, 900 9 04/038 FC−SW CLARiiON
AX1004
7 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris PCI Emulex LP9802−E9, 10, 11, 12, 13, 14, 15, 16, 17, 18 FC−AL, EMC Y See3
9 12/028 FC−SW CLARiiON
AX1004
8 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris PCI Fujitsu: PW008FC21, 2, 5, 6, PW008FC31, 2, 5, 6 FC−AL, EMC N See3
9 12/028 FC−SW CLARiiON
AX1004
1. Driver Version PFCA 3.0
2. Driver Version PFCA 2.2.1
3. For use in Asia Pacific/Japan only. Refer to Fujitsu Siemens Base Connectivity information for US/Europe.
4. AX100 requires the following minimum Flare revs:
AX100 02.16.102.5.004
AX100SC 02.16.101.5.004
5. Driver Version PFCA 2.2.1 requires patch 912069−21.
6. Driver Version PFCA 3.0 requires patch 914180−01.
7. Fujitsu requires all patches for Solaris 8 be obtained through Fujitsu in the form of a Solaris 8 PTF patch CD. The current patch CD is Solaris 8 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 8: 108528−29, 117000−05, 108974−50,109885−20, 110918−06, 117350−39 and PTF R06081
8. Fujitsu requires that all patches for Solaris 9 be obtained through Fujitsu in the form of a Solaris 9 PTF patch CD. The current patch CD is Solaris 9 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 9: 112233−12, 112834−06, 113277−45, 117171−17, 118558−30, and PTF R06081
9. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
10. Driver Version SAN 4.4.7a
11. Driver Version 6.01f
12. Driver Version SAN 4.4.8
13. Firmware Version 1.91a1
14. FCode Value 1.41a4
15. Driver Version 6.02f
16. Driver Version 6.02e
17. FCode Value 1.50a4
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
134 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2340−E−SP4, 5, 6, 7, 20 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP419, Server
SP4
Samsung ZSS150
135 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP419, Server
SP4
Samsung ZSS150;
Sun: x4100, x4200
136 HPQ Proliant BL20p (G2) Microsoft PCI−X23 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL20p (G2) FC−SW CLARiiON
Advanced Server 300874−B214, 6, 7, 22 AX100
SP419, Server
SP4
137 HPQ Proliant BL20p: (G3), (G4) Microsoft PCI−X23 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL20p (G3) FC−SW CLARiiON
Advanced Server 361426−B214, 6, 7, 22, Emulex−based AX100
SP419, Server BL20p (G3) Fibre Channel Mezzanine
SP4 HBA − 394757−B214, 13, 14, 16, 56
138 HPQ Proliant BL25p Microsoft PCI−X23 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL25p/BL45p FC−SW CLARiiON
Advanced Server 381881−B214, 6, 7, 10, 73 , Emulex−based AX100
SP419, Server BL25/30/35/45p Fibre Channel
SP4 Mezzanine HBA − 394588−B214, 13, 14,
16, 56
139 HPQ Proliant BL30p Microsoft PCI−X23 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2, 57
Windows 2000: for HP Proliant BL30p/BL35p FC−SW CLARiiON
Advanced Server 354054−B214, 6, 7, 22, Emulex−based AX100
SP419, Server BL25/30/35/45p Fibre Channel
SP4 Mezzanine HBA − 394588−B214, 13, 14,
16, 56
140 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 Emulex LP982−E4, 10, 13, 14, 15, 16, 36 FC−AL, EMC Y2, 3 See17
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
141 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 QLogic QLA2340−E−SP4, 5, 6, 7, 20 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
162 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, 28 See1
Windows 2000: Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced Server AX100
SP4, Server SP4
163 Intel SBXD62 Blade Server Microsoft PCI−X Intel: SBEFCM (SFF) Mezzanine HBA4, FC−SW EMC Y
Windows 2000: 6, 7, 10, 18 , SBEFCM4 (SFF) 4Gb CLARiiON
Advanced Server Mezzanine HBA4, 7, 10, 67, 68 AX100
SP4, Server SP4
164 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, See17
Windows 2000: Express Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON Y2, 3, 28
Advanced Server AX100
SP419, Server
SP4
165 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 3, 28 See17
Windows 2000: Express AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced Server AX100
SP419, Server
SP4
166 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, 28 See17
Windows 2000: Express, Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced Server PCI−X AX100
SR4850HW4/SR6850HW4; SP419, Server
SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
1. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
2. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
3. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
4. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
5. BIOS 1.47
6. Driver Version 9.1.2.10
7. Driver Version 9.1.2.11
8. Driver Version 9.1.2.10 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
9. BIOS 1.23
10. SNIA HBA API Supported.
11. BIOS 1.08
12. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
13. BIOS 1.70a3
14. Driver Version 2.41a1 SCSI FC Port driver
15. Firmware Version 1.91a5
16. Driver Version 2.40a3 SCSI FC Port driver
17. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
18. BIOS 1.43
19. Windows 2000 hosts running less than SP4 could be susceptible to data loss during LUN expansion operations. This issue is corrected by Microsoft in SP4, or by applying hotfix
327020. See EMC Solution IS emc73538 and Microsoft Knowledge Base article 327020 for more information.
20. PowerPath supported. ATF/CDE not supported.
21. Driver Version 9.1.2.11 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
22. BIOS 1.45
23. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
24. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
25. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar SCSI.)
26. BIOS 1.05
27. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
28. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
29. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions.
30. Firmware Version 2.50a8
31. Driver Version 2.41a1 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions.
32. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
33. Firmware Version 2.10a10
34. Driver Version 2.40a3
35. Firmware Version 1.91a1
36. The Emulex LP9XXX HBA family requires a host PCI bus capable of supplying 3.3 VDC bus power. The PCI slot can use either 3.3 VDC or 5.0 VDC signaling interfaces.
37. Firmware Version 2.50a6
38. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
39. This HBA is equivalent to the QLogic QLA2310.
40. BIOS 1.02
41. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
42. BIOS 1.06
43. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
44. Driver Version 9.1.2.14
45. BIOS 1.16
46. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
47. Accepts PCI−X 1.0 and 2.0 HBAs.
48. Update Rollup 1 for Windows 2000 SP4 is supported. For more information on this Rollup and to download the necessary software, please see
http://support.microsoft.com/default.aspx?scid=kb;en−us;891861
49. Host must be offline for interfamily Symmetrix microcode upgrade.
50. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
51. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons.
52. Proliant DL360 G4 servers with a BIOS prior to P52 may not be running a fully ACPI−compliant BIOS. Emulex 4gb HBAs require the latest ACPI−compliant BIOS and your server may
require Windows 2000 to be reinstalled. You do not need to reinstall Windows 2000 if you had an ACPI−compliant BIOS and then upgraded to a newer ACPI−compliant BIOS. You only
need to reinstall Windows 2000 if you did not have an ACPI BIOS or an ACPI−compliant BIOS before you upgraded the BIOS. Refer to Microsoft knowledge base article 256841 for
more information. (http://support.microsoft.com/?kbid=256841&sd=RMVP)
53. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
54. For IBM xSeries Servers running Windows 2000 with IBM ServerRaid controller 4M, the ServerRaid Driver must be 6.00 or above for use with EMC PowerPath 3.0 and above. IBM
driver can be downloaded at:
http://www−3.ibm.com/pc/support/site.wss/document.do?lndocid=MIGR−39723
55. This HBA is equivalent to the QLogic QLA2340.
56. Firmware Version 1.91a2
57. For external boot configurations running EMC Powerpath on Windows 2000, HP Proliant BL30p & BL35p require a minimum of Powerpath version 4.4.1.
58. Driver Version 2.30a2 SCSI FC Port driver
59. Driver Version 2.21a0
60. Driver Version 2.22a8
61. Firmware Version 1.90a4
62. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
63. For AX100 configurations, only Dell PowerVault systems with dual CPUs are supported.
64. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
65. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
66. Not supported with Emulex LP8000−EMC HBA.
67. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Requires Microsoft STORPort hotfix Q903081. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];903081 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
68. BIOS 1.12
69. If using Dell PERC Controller, requires PERC 2 or PERC 3 with OpenManager 3.0 and Array Manager 3.1. The afamgt.sys must be version 2.6.0.3486 (or above).
70. Requires minimum BIOS v4.01 rev A (5/17/2002) for use with Emulex HBAs.
71. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
72. HPQ Proliant ML350 (1GHz) : D04,F04 (11/13/2000) , HPQ Proliant ML350(600,733,800,866,933 MHz) : D02, F04 (11/13/2000).
73. BIOS 1.48
74. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
75. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
76. Supports Stratus OS 1.3.X through 2.1.X.
77. QLogic SANSurfer/SANBlade Manager is not supported. Use QLogic SANCLI utility.
78. QLogic SanBlade Manager is not supported.
79. Supports Stratus OS 2.0.X through 2.1.X.
80. BX600 uses an embedded fibre channel controller. Contact Fujitsu Siemens to acquire proper BIOS for embedded fibre channel controller.
122 Dell PowerEdge: 2900, 2950, 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP3, 11, 14, 15 FC−AL, EMC Y6, 8 See13
[x64] Storage Server: Express, FC−SW CLARiiON
Enterprise Edition R2, PCI−X AX100
Standard Edition R2
123 Dell PowerEdge: 2900, 2950 Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP11, 15, 20, FC−AL, EMC Y6, 8 See13
[x64] Storage Server: Express, QLE220−E−SP3, 11, 35, 36 , FC−SW CLARiiON
Enterprise Edition R2, PCI−X QLE2360−E−SP11, 15, 23 AX100
Standard Edition R2
124 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X24 Emulex: LP101−E1, 2, 11, 54, 56 , LP1050−E1, FC−AL, EMC Y6, 8 See9
8874)25 [x64]: DataCenter, 2, 11, 41, 54, 55 , LP1050−E1, 2, 4, 5, 11 , FC−SW CLARiiON
DataCenter R212 LP982−E1, 2, 11, 41, 54, 55 , LP982−E1, 2, 4, 5, AX100
11
125 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X24 IBM 19K1246: (QLA2310)11, 15, 17, 20, 32 , FC−AL, EMC Y6
8874)25 [x64]: DataCenter, (QLA2310)11, 20, 32, 46, 47, 48 ; FC−SW CLARiiON
DataCenter R212 AX100
IBM 24P0960: (QLA2340)11, 15, 17, 20, 43 ,
(QLA2340)11, 20, 43, 46, 47, 48
12. VDS (Virtual Disk Service) is currently supported for Windows 2003 R2 operating systems. EMC Solutions Enabler 6.2 (minimum version) is required to support VDS for Windows 2003
R2.
13. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
14. BIOS 1.08
15. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
16. BIOS 1.48
17. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
18. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
19. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
20. BIOS 1.47
21. Firmware Version 2.50a6
22. Firmware Version 2.10a10
23. BIOS 1.05
24. Accepts PCI−X 1.0 and 2.0 HBAs.
25. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
26. BIOS 1.43
27. Driver Version 9.0.2.17 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
28. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
29. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
30. BIOS 1.06
31. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar SCSI.)
32. This HBA is equivalent to the QLogic QLA2310.
33. BIOS 1.11
34. x64 versions of Windows 2003 require the Adaptec SAS SCSI driver from the IBM Support website.
35. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
36. BIOS 1.02
37. Firmware Version 2.50a8
38. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
39. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
40. Firmware Version 1.91a2
41. Driver Version 1.11a3
42. BIOS 1.45
43. This HBA is equivalent to the QLogic QLA2340.
44. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
45. Driver Version 1.10x1
46. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
47. Driver Version 9.1.2.16 STORPort Miniport Driver
48. Driver Version 9.1.2.15 STORPort Miniport Driver
49. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
50. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
51. BIOS 1.16
52. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
53. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
54. Driver Version 1.20a3 STORPort Miniport Driver
55. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
56. Driver Version 1.11a3 STORPort Miniport Driver
57. Firmware Version 1.91a1
58. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
59. Firmware Version 2.50a4
60. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com Requires Microsoft STORPort hotfix
Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently requires Service Pack 1 (SP1) to be installed before the hotfix
can be installed. STORPort Miniport Driver
61. Firmware Version 2.10a9
62. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
63. RPQ or Unisys Custom Engineering Request (CER) required.
64. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
65. BIOS 1.12
66. Driver Version 9.1.2.11
67. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
8 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 IBM 19K1246: (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
8874)61 [x86] DataCenter: R21, SP1 108, (QLA2310)2, 14, 28, 67, 108 ; FC−SW CLARiiON
AX100
IBM 24P0960: (QLA2340)2, 13, 14, 15, 29,
62, (QLA2340)2, 14, 28, 62, 67
9 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4 See11
8874)61 [x86] DataCenter: R21, SP1 QLA2340−E−SP2, 14, 28, 67 FC−SW CLARiiON
AX100
10 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/540 [x86] DataCenter: R21, 114 FC−SW CLARiiON
SP116 AX100
11 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 96, FC−AL, EMC Y3
[x86] DataCenter: R21, 113 FC−SW CLARiiON
SP116 AX100
12 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX: (LP1050)9, FC−AL, EMC Y3
[x86] DataCenter: R21, 111, 115, (LP1050)9, 113 FC−SW CLARiiON
SP116 AX100
13 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y
[x86] DataCenter: R21, 109, 110, 111 FC−SW CLARiiON
SP116; AX100
Microsoft Windows 2003
[x86] Enterprise Edition
SP116
14 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y3
[x86] DataCenter: R21, PCI−X 123, 126 FC−SW CLARiiON
SP116; AX100
Microsoft Windows 2003
[x86]: Enterprise Edition
R21, Standard Edition R21
15 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y
[x86] DataCenter: R21, 109, 110 FC−SW CLARiiON
SP116; AX100
Microsoft Windows 2003
[x86]: Enterprise Edition
SP116, Standard Edition
SP116
16 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 121 FC−AL, EMC Y3
[x86] DataCenter21 FC−SW CLARiiON
AX100
17 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/540 [x86] DataCenter21 128 FC−SW CLARiiON
AX100
18 NEC Express 5800 320Ma83, 94 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 25, 37, FC−AL, EMC Y3 See11
[x86] Enterprise Edition 68 FC−SW CLARiiON
AX100
19 Stratus ftServer: 430083, 460083 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 37, 68, FC−AL, EMC N See11
[x86] Enterprise Edition 98 FC−SW CLARiiON
AX100
20 Stratus ftServer: 230065, 330045, 430083, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 43, 44 , FC−AL, EMC N See11
460083, 560045, 660045 [x86] Enterprise Edition QLA210−E−SP19, 41, 43, 54 FC−SW CLARiiON
AX100
21 HPQ Proliant: BL460c (404664−B21), BL465c Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403433−B21), BL465c (403434−B21), [x86] Enterprise Edition Express HP c−Class Bladesystem FC−SW CLARiiON
BL465c (407234−B21), BL465c (403619−B21)53, 88, 89 AX100
(407235−B21), BL480c (404704−B21)
22 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 25, 37, FC−AL, EMC Y3 See11
[x86] Enterprise Edition 68 FC−SW CLARiiON
AX100
23 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 25, 37, FC−AL, EMC N See11
[x86] Enterprise Edition 68, 98 FC−SW CLARiiON
AX100
35 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP2, 14, 28, 29, 67, FC−AL, EMC Y3, 4 See11
320Lc−R [x86] Enterprise Edition: 68 FC−SW CLARiiON
R21, SP116 AX100
36 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, FC−AL, EMC Y3
[x86] Enterprise Edition: 111, 117 FC−SW CLARiiON
R21, SP116 AX100
37 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 116 FC−AL, EMC Y3
Model 300 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116 AX100
38 Unisys: FS1300, Libra Model 300 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86] Enterprise Edition: 111, 117 FC−SW CLARiiON
R21, SP116 AX100
39 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/530, ES7000/540, ES7000/550, [x86] Enterprise Edition: 118 FC−SW CLARiiON
ES7000/560 [32−Bit] R21, SP116 AX100
40 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 96, FC−AL, EMC Y3
[x86] Enterprise Edition: 116 FC−SW CLARiiON
R21, SP116 AX100
41 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI Emulex LP101−E2, 6, 9, 17, 30 FC−AL, EMC Y3, 4 See10
DL36018, DL58018, ML350(G2)18, ML35018, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, R21, SP116; AX100
ML530(G3)18, ML53018, ML57018, ML75018;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x340 (4500R), x342, x350 SP116
(6000R), x370
42 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI Emulex LP982−E2, 5, 6, 8, 9, 17 FC−AL, EMC Y3, 4 See10
DL36018, DL58018, ML350(G2)18, ML35018, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, R21, SP116; AX100
ML530(G3)18, ML53018, ML57018, ML75018;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x342, x350 (6000R), x370 SP116
43 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 7, 9, 32 , LP982−E2, FC−AL, EMC Y3, 4 See10
2500, 255080, 4300, 4350, 4400, 6100, 6300, [x86] Enterprise Edition: 5, 6, 7, 8, 9 FC−SW CLARiiON
6350, 6400, 6450, 8450 R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
44 Dell PowerEdge: 1550, 2450, 2500, 255080, Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 7, 8, 9 , FC−AL, EMC Y3, 4 See10
4400, 6350, 6400, 645081, 8450 [x86] Enterprise Edition: LP1150−E2, 7, 8, 9, 19, 23, 32 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
45 HPQ Proliant: 850018, DL32018, Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 8, 9, 17 , FC−AL, EMC Y3, 4 See10
DL360(G2)18, DL36018, DL380(G2)18, [x86] Enterprise Edition: LP1150−E2, 8, 9, 17, 19, 23, 30 FC−SW CLARiiON
DL380(G3)18, DL38018, DL58018, R21, SP116; AX100
ML350(G2)18, ML35018, ML370(G2)18,
ML37018, ML530(G2)18, ML530(G3)18, Microsoft Windows 2003
ML53018, ML57018, ML75018; [x86] Standard Edition: R21,
SP116
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
190 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP2, 14, 25, 29, 37, FC−AL, EMC Y3, 4 See11
320Lc−R [x86] Enterprise Edition21 68 FC−SW CLARiiON
AX100
191 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 121 FC−AL, EMC Y3
Model 300 [x86] Enterprise Edition21 FC−SW CLARiiON
AX100
319 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ AE311A/FC1142SR (QLE2460)2, FC−AL, EMC Y3, 31
[x86]: Enterprise Edition21, 19, 20, 25, 37, 69 FC−SW CLARiiON
Standard Edition21 AX100
320 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86]: Enterprise Edition21, for HP Proliant BL25p/BL45p FC−SW CLARiiON
Standard Edition21 381881−B212, 25, 29, 37, 87 AX100
321 HPQ Proliant: DL360(G3)18, DL360(G4)18, Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)2, 6, 8, 9, 22, 24 , FC−AL, EMC Y3
DL56018, DL74018, DL760 (G2)18, DL76018, [x86]: Enterprise Edition21, A7388A (LP1050)2, 6, 8, 9, 22, 24 , FC−SW CLARiiON
ML570(G2)18 Standard Edition21 AD167A/FC2143 (LP1150)8, 9, 19, 22, 24, AX100
129, FCA2214 (QLA2340)2, 14, 25, 29, 37 ,
FCA2408 (LP982)2, 6, 8, 9, 19, 22, 24
322 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, Y3,
[x86]: Enterprise Edition21, 19, 22, 24, 35 , AE311A/FC1142SR FC−SW CLARiiON 12
Standard Edition21 (QLE2460)2, 19, 20, 25, 37, 69 AX100
323 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 19, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, 20, 25, AE369A/FC1243 (QLA2462)2, 19, FC−SW CLARiiON
Standard Edition21 20, 25; AX100
QLogic: QLE220−E−SP2, 19, 48, 49, 53 ,
QLE2360−E−SP2, 29, 40, 51, 52 ,
QLE2460−E−SP2, 19, 20, 25, 29, 37
361 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, 12
[x86]: Enterprise Edition21, Express, 19, 22, 24, 35 , AE311A/FC1142SR FC−SW CLARiiON
Standard Edition21 PCI−X (QLE2460)2, 19, 20, 25, 37, 69 AX100
362 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 19, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, 20, 25, AE369A/FC1243 (QLA2462)2, 19, FC−SW CLARiiON
Standard Edition21 PCI−X 20, 25; AX100
QLogic QLA2460−E−SP2, 19, 20, 25, 29,
37
363 HPQ Proliant DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP2, 19, 48, 49, 53 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
364 HPQ Proliant: DL380(G4)18, DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP2, 29, 40, 51, 52 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
365 HPQ Proliant: DL380(G4)18, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4 See11
DL580(G3)18, DL580(G4) [x86]: Enterprise Edition21, Express, 37 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
366 HPQ Proliant: DL380(G5), DL580(G3)18, Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4, 12, See11
DL580(G4) [x86]: Enterprise Edition21, Express, 37 FC−SW CLARiiON Y3, 4, 31
Standard Edition21 PCI−X AX100
393 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA2, FC−SW EMC Y3
[x86]: Enterprise Edition, 19, 25, 37, 66 , SBEFCM4 (SFF) 4Gb CLARiiON
Standard Edition Mezzanine HBA2, 19, 25, 99, 100 AX100
394 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12
Standard Edition21 91 AX100
395 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12,
Standard Edition21 91 AX100 Y3, 4, 31
396 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express AHWFCMOD2, 19, 25, 29, 37, 90, 91 CLARiiON Y3, 4, 12
Standard Edition21 AX100
397 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express AHWFCMOD2, 19, 25, 29, 37, 90, 91 CLARiiON Y3, 4, 12,
Standard Edition21 AX100 Y3, 4, 31
398 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition21 PCI−X 91 AX100
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
399 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12,
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition21 PCI−X 91 AX100 Y3, 4, 31
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
400 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See10
[x86]: Enterprise Edition21, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON
Standard Edition21 91 AX100
401 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12
Standard Edition21 91 AX100
1. VDS (Virtual Disk Service) is currently supported for Windows 2003 R2 operating systems. EMC Solutions Enabler 6.2 (minimum version) is required to support VDS for Windows 2003
R2.
2. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
3. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
4. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
5. Driver Version 1.11a3
6. Firmware Version 1.91a5
7. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
8. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver
to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
9. BIOS 1.70a3
10. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
11. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
12. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
13. Driver Version 9.1.2.16 STORPort Miniport Driver
14. BIOS 1.47
15. Driver Version 9.1.2.15 STORPort Miniport Driver
16. Supports LUNs greater than 2TB in size. Minimum Service Pack 1 (SP1) required.
17. Driver Version 1.20a3 STORPort Miniport Driver
18. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
19. SNIA HBA API Supported.
20. BIOS 1.08
21. Maximum supported LUN size is 2TB for Windows 2003 without Service Pack 1 (SP1.)
22. Driver Version 1.11a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
23. Firmware Version 2.10a10
24. Driver Version 1.20a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
25. Driver Version 9.1.2.16 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
26. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
27. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
28. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
29. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
30. Driver Version 1.11a3 STORPort Miniport Driver
31. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar
SCSI.)
32. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
33. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
34. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003.
35. Firmware Version 2.50a6
36. BIOS 1.11
37. Driver Version 9.1.2.15 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
38. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
39. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
40. BIOS 1.05
41. BIOS 1.23
42. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
43. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
44. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
45. Supports Stratus OS 3.1.x.
46. Firmware Version 2.50a8
47. Driver Version 1.20a3
48. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
49. BIOS 1.02
50. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
51. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
52. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
53. Driver Version 9.1.2.19 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
54. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. SCSI Miniport (SCSIPort) Driver
55. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
56. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
57. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
58. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
59. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
60. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI FC Port driver As of 2.40a2 Microsoft will no longer allow the
Emulex Port Driver to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO
solution and block submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
61. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
126. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
127. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
128. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
129. Firmware Version 2.10a9
130. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
131. Driver Version 9.1.2.15
132. Driver Version 1.11u1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
Novell Netware
Novell Netware
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5 SP31, 22 Express QLE2360−E−SP19, 21, FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL380(G4)29, DL580(G3)29, ML370(G4)29; 26, 27 9, 10, 11, 12, 13, 15,
16, 23
IBM xSeries x336 (8837)31
2 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5 SP31, 22 Express QLE2460−E−SP19, 20, 21 FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL580(G3)29, ML370(G4)29 9, 10, 11, 12, 13, 15,
16, 23
3 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y
6.5 SP31, 22 QLA2340−E−SP18, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX200 S2, RX300, RX300 S2, 9, 10, 11, 12, 13, 15,
TX150, TX200, TX200 S2, TX300, TX300 S2; 16, 23
6 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255028, 4300, 4350, 4400, Novell Netware PCI QLogic: FC−AL, EMC CLARiiON Y4, 5, 6,
6100, 6300, 6350, 6400, 6450, 8450; 6.5: SP1.11, QLA200−E−SP2, 3, FC−SW AX100 7, 8, 9, 10,
SP21 QLA2340−E−SP3, 18 11, 12, 13,
14, 15, 16,
HPQ Proliant: DL32029, DL360(G2)29, DL36029, DL58029, ML350(G2)29, 17
ML350(G3)29, ML35029, ML370(G2)29, ML37029, ML530(G2)29,
ML530(G3)29, ML53029, ML57029, ML75029;
IBM: Netfinity 4500R, xSeries x225, xSeries x230, xSeries x232, xSeries
x240, xSeries x250, xSeries x330, xSeries x335, xSeries x340 (4500R),
xSeries x342, xSeries x350 (6000R), xSeries x370
7 Dell PowerEdge: 1800, 2800 Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y4, 5, 6,
6.5: SP1.11, Express QLE2360−E−SP3, 26 FC−SW AX100 7, 8, 9, 10,
SP21 11, 12, 13,
14, 15, 16,
17
8 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON Y4, 5, 6,
6.5: SP1.11, 3 FC−SW AX100 7, 8, 9, 10,
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029, SP21 11, 12, 13,
14, 15, 16,
DL760 (G2)29, DL76029, ML570(G2)29; 17
11 Dell PowerEdge 1850; Novell Netware PCI, QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON Y4, 5, 6,
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029, 6.5: SP1.11, PCI−X 3 FC−SW AX100 7, 8, 9, 10,
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29; SP21 11, 12, 13,
14, 15, 16,
17
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
Novell Netware
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot
12 Dell PowerEdge 1850; Novell Netware PCI, QLogic FC−AL, EMC CLARiiON Y4, 5, 6,
Fujitsu Siemens Primergy: RX600, TX600; 6.5: SP1.11, PCI−X QLA2340−E−SP3, 18 FC−SW AX100 7, 8, 9, 10,
SP21 11, 12, 13,
14, 15, 16,
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029, 17
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
13 HPQ Proliant BL20p (G3) Novell Netware PCI−X25 HPQ Dual−port Fibre FC−AL, EMC CLARiiON N
6.5: SP1.11, Channel Adapter for HP FC−SW AX100
SP21; Proliant BL20p (G3)
361426−B213, 24
Novell Netware
6.51
14 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255028, 4300, 4350, 4400, Novell Netware PCI QLogic: FC−AL, EMC CLARiiON Y
6100, 6300, 6350, 6400, 6450, 8450; 6.5: SP31, 22, QLA200−E−SP2, 19, 21, FC−SW AX1004, 5, 6, 7, 8,
SP41, 22, QLA2340−E−SP18, 19, 21 9, 10, 11, 12, 13, 15,
HPQ Netserver LC: 2000 U3, 2000r; SP4a22, SP522 16, 23
HPQ Netserver LH: (LH Pro), 3, 300033, 4, 6000/LH 6000r, II, PRO, lll;
HPQ Netserver: LP 2000r, LT 6000R, LX PRO, LXR 8000, LXR 8500, LXR
PRO, LXR PRO8;
HPQ Proliant: 160029, 185029, 250029, 300029, 500029, 550029, 600029,
6400R, 650029, 700029, 800029, 850, 850029, DL32029, DL360(G2)29,
DL36029, DL58029, ML350(G2)29, ML35029, ML370(G2)29, ML37029,
ML530(G2)29, ML530(G3)29, ML53029, ML57029, ML75029;
IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20, 5600, 6000R,
7000, 7000 M1034, 7100, 7600, 8500, 8500R;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335, x340 (4500R), x350
(6000R)
15 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON Y
6.5: SP31, 22, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX300, TX150, TX200, TX300; SP41, 22, 9, 10, 11, 12, 13, 15,
SP4a22, SP522 16, 23
HPQ Proliant: DL360(G3)29, DL56029, DL74029, DL760 (G2)29, DL76029,
ML570(G2)29;
IBM xSeries: x235, x255, x336 (8837)31, x346 (8840)31, x3850/x366
(8863)30;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
16 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI, QLogic: FC−AL, EMC CLARiiON Y
6.5: SP31, 22, PCI−X QLA200−E−SP2, 19, 21, FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: RX600, TX600; SP41, 22, QLA2340−E−SP18, 19, 21 9, 10, 11, 12, 13, 15,
SP4a22, SP522 16, 23
HPQ Proliant: DL360(G4)29, DL380(G2)29, DL380(G3)29, DL380(G4)29,
DL38029, DL580(G2)29, DL580(G3)29, ML350(G3)29, ML370(G3)29,
ML370(G4)29;
IBM xSeries: x342, x345 (8670), x360, x365, x370, x440, x445 (8870);
Samsung SS140
17 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5: SP41, 22, Express QLE2360−E−SP19, 21, FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL380(G4)29, DL580(G3)29, ML370(G4)29; SP4a22, SP522 26, 27 9, 10, 11, 12, 13, 15,
16, 23
IBM xSeries x336 (8837)31
18 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic: FC−AL, EMC CLARiiON Y
6.5: SP41, 22, Express, QLA200−E−SP2, 19, 21, FC−SW AX1004, 5, 6, 7, 8,
SP4a22, SP522 PCI−X QLA2340−E−SP18, 19, 9, 10, 11, 12, 13, 15,
21, QLE2360−E−SP19, 16, 23
21, 26, 27
19 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5: SP422, Express QLE2460−E−SP19, 20, 21 FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL580(G3)29, ML370(G4)29 SP4a22, SP522 9, 10, 11, 12, 13, 15,
16, 23
20 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5: SP422, Express, QLE2460−E−SP19, 20, 21 FC−SW AX1004, 5, 6, 7, 8,
SP4a22, SP522 PCI−X 9, 10, 11, 12, 13, 15,
16, 23
21 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y
6.5: SP4a22, QLA2340−E−SP18, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX300, RX300 S2, TX150, SP522 9, 10, 11, 12, 13, 15,
TX200, TX300; 16, 23
Novell Netware
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot
23 Dell PowerEdge: 1800, 2800 Novell Netware PCI QLogic FC−AL, EMC CLARiiON N
6.51 Express QLE2360−E−SP3, 26 FC−SW AX100
24 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON N
6.51 3 FC−SW AX100
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029,
DL760 (G2)29, DL76029, ML570(G2)29;
IBM xSeries: x235, x255, x360, x365, x3850/x366 (8863)30, x440;
LangChao: NC2000, NF420;
Samsung SS210
25 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON N
6.51 QLA2340−E−SP3, 18 FC−SW AX100
Fujitsu Siemens Primergy: RX200, RX300, TX150, TX200, TX300;
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029,
DL760 (G2)29, DL76029, ML570(G2)29;
IBM xSeries: x235, x255, x360, x365, x3850/x366 (8863)30, x440;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
26 Dell PowerEdge 1850; Novell Netware PCI, QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON N
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029, 6.51 PCI−X 3 FC−SW AX100
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
27 Dell PowerEdge 1850; Novell Netware PCI, QLogic FC−AL, EMC CLARiiON N
Fujitsu Siemens Primergy: RX600, TX600; 6.51 PCI−X QLA2340−E−SP3, 18 FC−SW AX100
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029,
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
1. PowerPath is not supported in conjunction with host−based mirroring.
2. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 6.80g
4. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
5. No MirrorView or SnapView used on boot LUNs.
6. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
7. Novell Storage Services supported.
8. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
9. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After Abend".
When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
10. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
11. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any found in
previous boot documentation.
12. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
13. Remote boot not supported with PERC controllers enabled in system BIOS.
14. Refer to the Customer Service website or your EMC Service Personnel for the latest documentation.
15. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
16. Supports eight (8) hosts per array.
17. Edit config.sys with the following: Files=100 Buffers=99
18. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Driver Version 6.90m
20. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. SNIA HBA API Supported.
22. Novell OES is supported on this kernel.
23. Edit config.sys with the following: Files=100, Buffers=99
24. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
26. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
28. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
29. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
30. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
31. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
32. Must use standard PCI 32bit/33MHz slot for SCSI
33. HP Netserver LH3000 U3 is supported in the same configurations as the standard LH 3000.
34. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
18 Dell PowerEdge 1950; Oracle Enterprise PCI QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
19 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise PCI QLogic QLE2360−E−SP4, 20, 21 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; v2.6.9−42.0.0.0.1.EL AX100
Samsung ZSS230
20 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Oracle Enterprise PCI QLogic QLE2360−E−SP4, 9, 20, 21 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)43;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
21 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Oracle Enterprise PCI QLogic QLE2460−E−SP4, 9, 18 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
22 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, QLogic: QLA200−E−SP4, 9, 24, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X QLA210−E−SP4, 9, 24 AX100
HPQ Proliant ML350(G4)11;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
23 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP1050−E1, 2, 9, 10; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, QLogic QLA2340−E−SP3, 4, 9 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX100
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
24 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP982−E1, 2, 9 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
25 HPQ Proliant ML350(G4)11 Oracle Enterprise PCI Emulex: LP1050−E1, 2, 10, LP982−E1, 2; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, AX100
AD167A/FC2143 (LP1150)1, 2, 9, 12,
AE369A/FC1243 (QLA2462)4, 9, 34;
QLogic QLA2340−E−SP3, 4
26 Dell PowerEdge: 2900, 2950, 6950; Oracle Enterprise PCI Emulex: LP1050Ex−E1, 2, 9, 19, LPe111−E1, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 2, 9, 23, LPe1150−E1, 2, 9, 17; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX100
QLogic: QLE2360−E−SP4, 9, 20, 21 ,
Intel: SR1500/S5000PAL, SR2500/S5000PAL QLE2460−E−SP4, 9, 18
27 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) Oracle Enterprise PCI IBM: 24P0960 (QLA2340)3, 4, 9, 28, 24P8053 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, (QLA2342)3, 4, 9; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
QLogic: QLA2460−E−SP4, 9, 18,
QLE2360−E−SP4, 9, 30, QLE2460−E−SP4, 9,
29
28 NEC Express 5800: 120Li, 120Rg−1, 120Ri−2, 140Hf, Oracle Enterprise PCI NEC: N8190−120 (LP1050)1, 10, 26, 27 , FC−AL, EMC Y
140Re−4 Linux [32−Bit] 4 U4 Express, N8190−127 (LPe1150)1, 17, 26, 27 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
29 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, Oracle Enterprise PCI QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
6950; Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550, AS2500;
HPQ Proliant ML350(G4)11;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
30 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise PCI Emulex: LP101−E1, 2, 9, 19, LP1050−E1, 2, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 10, LP982−E1, 2; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X42 AX100
QLogic: QLA200−E−SP4, 9, 24,
QLA210−E−SP4, 9, 24, QLA2340−E−SP3, 4,
QLE220−E−SP9, 14, 15
31 Dell PowerEdge 1855 Oracle Enterprise PCI−X Dell: 2342M3, 4, LPe1105−M1, 2, 9, 17, FC−AL, EMC Y
Linux [32−Bit] 4 U4 QME24624, 9, 40 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
52 HPQ Proliant DL380(G5) Oracle Enterprise PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, AE369A/FC1243 (QLA2462)4, 9, 34 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
53 Dell PowerEdge: 1800, 2800; Oracle Enterprise PCI, PCI QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) v2.6.9−42.0.0.0.1.EL PCI−X AX100
54 HPQ Proliant: DL14511, DL380(G2)11, DL380(G3)11, Oracle Enterprise PCI, Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
DL380(G4)11, DL38011, DL38511, DL580(G2)11, Linux [32−Bit] 4 U4 PCI−X QLogic: QLA200−E−SP4, 9, 24, FC−SW CLARiiON
DL580(G3)11, DL58511, ML370(G3)11, ML370(G4)11; v2.6.9−42.0.0.0.1.EL QLA210−E−SP4, 9, 24, QLE220−E−SP9, 14, AX100
15
Samsung SS140
55 Dell PowerEdge: 1800, 1850, 2800, 2850; Oracle Enterprise PCI, Emulex: LP1050−E1, 2, 9, 10, LP982−E1, 2, 9; FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model 8848); v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP3, 4, 9 AX100
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
56 HPQ Proliant: DL14511, DL380(G2)11, DL380(G3)11, Oracle Enterprise PCI, Emulex: LP1050−E1, 2, 10, LP982−E1, 2; FC−AL, EMC Y
DL380(G4)11, DL38011, DL38511, DL580(G2)11, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
DL580(G3)11, DL58511, ML370(G3)11, ML370(G4)11 v2.6.9−42.0.0.0.1.EL HPQ AD167A/FC2143 (LP1150)1, 2, 9, 12 AX100
57 HPQ Proliant: DL380(G4)11, DL38511, DL58511, Oracle Enterprise PCI, HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, FC−AL, EMC Y
ML370(G4)11 Linux [32−Bit] 4 U4 PCI−X AE369A/FC1243 (QLA2462)4, 9, 34 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
58 IBM eServer: 325 (Model 8835), 326 (Model 8848) Oracle Enterprise PCI, IBM 24P0960 (QLA2340)3, 4, 9, 28 FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
59 HPQ Proliant: DL14511, DL380(G4)11, DL38511, Oracle Enterprise PCI, QLogic QLA2340−E−SP3, 4 FC−AL, EMC Y
DL580(G2)11, DL580(G3)11, DL58511, ML370(G3)11, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
ML370(G4)11; v2.6.9−42.0.0.0.1.EL AX100
Samsung SS140
60 Bull NovaScale 2320 Oracle Enterprise PCI−X Bull 2Gbps FC Mezzanine Card − Dual port FC−SW EMC Y
Linux [32−Bit] 4 U4 for NovaScale Blade Series: CLARiiON
v2.6.9−42.0.0.0.1.EL CFSN202−11004, 16, CFSN202−11004, 25; AX100
Bull 2Gbps FC Mezzanine Card − Dual port
mini for NovaScale Blade 2021:
CFSN202−21004, 16, CFSN202−21004, 25;
Bull SBEFCM (SFF) Mezzanine: HBA4, 16,
HBA4, 9, 25;
Bull SBEFCM4 (SFF) 4Gb Mezzanine HBA4,
13
77 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI Fujitsu Siemens: BX600−FC22Q11, FC−AL, EMC N1, 2
S2F34, S234; v2.4.21−32.EL7, 8 27, 33, BX600−FC22Q11, 27, 33, 38 , FC−SW CLARiiON
BX600−FC22Q5, 11, 27, 33 AX100
Fujitsu Siemens Primergy BX62034
78 NEC Express 5800: 120Rd−1, 140Hd, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI NEC N8190−120: (LP1050)16, 19, FC−AL, EMC N1, 2
140Rc−4, 180Rd−4 v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; 35, 60, (LP1050)16, 19, 35, 61, 62 FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
79 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex LP1050Ex−E16, 19, 27, 44 ; FC−AL, EMC Y1, 2
2850, 6800, 6850; v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; Express QLogic QLE2360−E−SP27, 29, 36, FC−SW CLARiiON
37 AX100
Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
HR−6850; v2.4.21−32.0.1.EL7, 8
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
80 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E16, 17, 19, 27 , FC−AL, EMC Y1, 2
2850; v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; Express, LP1050−E16, 17, 18, 27 ; FC−SW CLARiiON
PCI−X AX100
LangChao: NC3000, NC3500, NF500, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA200−E−SP4, 14, 27, 38
NF520 v2.4.21−32.0.1.EL7, 8
81 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E16, 17, 19, FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; Express, LP1050−E16, 17, 18, LP982−E16, 17; FC−SW CLARiiON
PCI−X AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic: QLA200−E−SP14, 15,
v2.4.21−32.0.1.EL7, 8 QLA2340−E−SP11, 12, 15
82 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)13, AX100
DL360(G4)13, DL56013, DL74013, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
DL760 (G2)13, DL76013, ML570(G2)13 v2.4.21−32.0.1.EL7, 8
83 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex LP101−E16, 19, 20 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
84 Dell PowerEdge: 2600, 2650, 6800, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP101−E16, 17, 19, 27 , FC−AL, EMC Y1, 2
6850; v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; LP1050−E16, 17, 18, 27 ; FC−SW CLARiiON
AX100
Digital Henge SH4500R4; Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA200−E−SP4, 14, 27, 38
IBM xSeries: x336 (8837)46, x346 v2.4.21−32.0.1.EL7, 8
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS370, SS3840, ZSS150,
ZSS230
103 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLE2460−E−SP27, 29, 56 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−40.EL7, 25 Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
104 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E16, 19, 27, 31 , FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, LP1050−E16, 18, 27, 31 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X LP1050Ex−E16, 19, 27, 31 , AX100
AS2500; LP982−E16, 27, 31, LPe111−E16, 27,
31, 54, LPe1150−E16, 27, 31, 42 ;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL QLogic: QLA200−E−SP14, 27, 30,
QLA2340−E−SP11, 27, 29,
QLE2360−E−SP27, 29, 36, 37 ,
QLE2460−E−SP27, 29, 56
105 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E16, 19, 31, FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, LP1050−E16, 18, 31, LP982−E16, 31; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 29, 111 ,
AD167A/FC2143 (LP1150)16, 27, 28,
31, AE369A/FC1243 (QLA2462)27,
29, 111;
118 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ: Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−40.EL7, 25 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 29, AX100
Emulex−based BL25/30/35/45p
Fibre Channel Mezzanine HBA −
394588−B2116, 22, 23, 31
119 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−40.EL7, 25 31, 35 FC−SW CLARiiON
140Rd−4 AX100
120 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 31, FC−AL, EMC Y
v2.4.21−40.EL7, 25 35, 68 FC−SW CLARiiON
AX100
121 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y
2650, 2850, 4600, 6600, 6650, 6800, v2.4.21−40.EL7, 25 FC−SW CLARiiON
6850; AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
122 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic QLE220−E−SP27, 93, 94, 108 FC−AL, EMC Y
HR−6850; v2.4.21−40.EL7, 25 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
127 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X83 QLogic: QLA210−E−SP14, 27, 29, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−40.EL7, 25 QLE220−E−SP27, 93, 94, 108 FC−SW CLARiiON
AX100
128 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 31, 42 , FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, QME246227, 29, 41 FC−SW CLARiiON
PCI−X AX100
129 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex LP982−E16, 31 FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, AX100
ML370(G3)13, ML370(G4)13
130 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E16, 19, 27, 31 , FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−40.EL7, 25 PCI−X LP1050−E16, 18, 27, 31 , LP982−E16, FC−SW CLARiiON
27, 31; AX100
QLogic QLA200−E−SP14, 27, 30
131 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E16, 19, 31, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−40.EL7, 25 PCI−X LP1050−E16, 18, 31; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 HPQ AD167A/FC2143 (LP1150)16,
27, 28, 31 ;
QLogic QLA200−E−SP14, 29
132 HPQ Proliant: DL380(G4)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
ML370(G4)13 v2.4.21−40.EL7, 25 PCI−X (QLA2460)27, 29, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 29, AX100
111
133 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
134 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 29 FC−AL, EMC Y
Fujitsu Siemens Primergy RX800 S2; v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 AX100
135 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 30 FC−AL, EMC Y
Samsung ES470 v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
AX100
136 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP11, 29 FC−AL, EMC Y
HPQ Proliant: DL380(G2)13, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL580(G2)13, DL580(G3)13,
ML370(G3)13, ML370(G4)13
137 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLE220−E−SP27, 93, 94, 108 FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
138 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−47.EL7, 25 LP1050−E16, 18, 26, LP982−E16, 26 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
139 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL36013, DL58013, ML350(G2)13, v2.4.21−47.EL7, 25 26, 27, 28 ; FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, QLogic: QLA200−E−SP14, 24, AX100
ML37013, ML530(G2)13, ML530(G3)13, QLA210−E−SP14, 24, 27,
ML53013, ML57013, ML75013 QLA2340−E−SP11, 24,
QLE220−E−SP27, 93, 94
140 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.4.21−47.EL7, 25 26, 35 FC−SW CLARiiON
AX100
146 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic QLE2460−E−SP24, 27, 56 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−47.EL7, 25 Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
147 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E16, 19, 26, 27 , FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, LP1050−E16, 18, 26, 27 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X LP1050Ex−E16, 19, 26, 27 , AX100
AS2500; LP982−E16, 26, 27, LPe111−E16, 26,
27, 54, LPe1150−E16, 26, 27, 42 ;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL QLogic: QLA200−E−SP14, 24, 27,
QLA2340−E−SP11, 24, 27,
QLE2360−E−SP24, 27, 36, 37 ,
QLE2460−E−SP24, 27, 56
148 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, LP1050−E16, 18, 26, LP982−E16, 26; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)24, 27, 111 ,
AD167A/FC2143 (LP1150)16, 26, 27,
28, AE369A/FC1243 (QLA2462)24,
27, 111;
161 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ: Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−47.EL7, 25 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 24, AX100
Emulex−based BL25/30/35/45p
Fibre Channel Mezzanine HBA −
394588−B2116, 22, 23, 26
162 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−47.EL7, 25 26, 35 FC−SW CLARiiON
140Rd−4 AX100
163 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 26, FC−AL, EMC Y
v2.4.21−47.EL7, 25 35, 68 FC−SW CLARiiON
AX100
171 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X83 QLogic: QLA210−E−SP14, 24, 27, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−47.EL7, 25 QLE220−E−SP27, 93, 94 FC−SW CLARiiON
AX100
172 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Dell: LPe1105−M16, 26, 27, 42 , FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, QME246224, 27, 41 FC−SW CLARiiON
PCI−X AX100
173 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, LP1050−E16, 18, 26, LP982−E16, 26, FC−SW CLARiiON
PCI−X LPe111−E 16, 26, 27, 54 , AX100
LPe1150−E16, 26, 27, 42 ;
HPQ: A8002A/FC2142SR
(LPe1150)16, 26, 27, 68 ,
AD167A/FC2143 (LP1150)16, 26, 27,
28, AE311A/FC1142SR
(QLE2460)24, 27, 56,
AE312A/FC1242SR (QLE2462)24,
27, 56;
179 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, QLogic QLA210−E−SP14, 24, 27 FC−AL, EMC Y
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−47.EL7, 25 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
180 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, QLogic QLE220−E−SP27, 93, 94 FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−47.EL7, 25 PCI−X FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
181 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP101−E16, 19, 60; FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, QLogic QLA2340−E−SP11, 38, 65 FC−SW CLARiiON
x350 (6000R), x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
182 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP1050−E16, 18, 62 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
HPQ Proliant: 850013, DL32013,
DL360(G2)13, DL36013, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
183 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex: LP101−E16, 19, 62, FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, LP982−E16, 62 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
184 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 62 ; FC−AL, EMC N1, 2
2850 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, Express QLogic QLE2360−E−SP15, 36, 37 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
185 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Dell 2342M11 FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
186 IBM xSeries: x235, x255, x360, x365, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Emulex LP101−E16, 19, 60; FC−AL, EMC N1, 2
x440 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, QLogic QLA2340−E−SP11, 38, 65 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
187 HPQ Proliant BL40p Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 15, 65 FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
188 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, Emulex LP101−E16, 19, 60; FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, PCI−X QLogic QLA2340−E−SP11, 38, 65 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
189 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, Emulex LP982−E16, 62; FC−AL, EMC N1, 2
HPQ Proliant: DL380(G2)13, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, PCI−X QLogic QLA2340−E−SP11, 15 FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
DL580(G2)13, DL580(G3)13, v2.4.21−15.0.4.EL7
ML370(G3)13
190 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP1050−E16, 18, 60 FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
x350 (6000R), x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7
191 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP982−E16, 60 FC−AL, EMC N1, 2
x250, x330, x335, x342, x350 (6000R), v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7
192 IBM xSeries: x235, x255, x360, x365, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Emulex: LP1050−E16, 18, 60, FC−AL, EMC N1, 2
x440 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, LP982−E16, 60 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7
250 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI QLogic QLE2460−E−SP27, 29, 56 FC−AL, EMC Y1, 2
2800, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
251 Dell PowerEdge: 2900, 2950 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
PCI−X 27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 27, 29
252 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E16, 19, 44, FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, LP1050−E16, 18, 44, LP982−E16, 44; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 29, 111 ,
AE369A/FC1243 (QLA2462)27, 29,
111;
254 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, 27, 28, 44 FC−SW CLARiiON
PCI−X AX100
255 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Dell 2342M11, 29 FC−AL, EMC N1, 2
Unisys ES3105 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
256 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Dell: LPe1105−M16, 27, 42, 44 , FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL QME246227, 29, 41 FC−SW CLARiiON
AX100
257 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex LP1050−E16, 27, 32, 44 FC−AL, EMC Y1, 2
RX300 S2, TX200 S2, TX300 S2 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
264 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X HPQ: Dual−port Fibre Channel FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 29, AX100
Emulex−based BL25/30/35/45p
Fibre Channel Mezzanine HBA −
394588−B2116, 22, 23, 44
265 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 35, 79 FC−SW CLARiiON
AX100
266 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC: N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 35, 44, N8190−127 (LPe1150)16, 35, FC−SW CLARiiON
44, 68 AX100
267 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y1, 2
2650, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant BL40p;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
268 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic: QLA200−E−SP14, 29, FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL QLA210−E−SP14, 27, 29, FC−SW CLARiiON
HPQ Proliant: DL360(G3)13, QLA2340−E−SP11, 29 AX100
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
272 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X83 Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 27, 29
273 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 42, 44 , FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, QME246227, 29, 41 FC−SW CLARiiON
PCI−X AX100
274 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex LP982−E16, 44; FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X QLogic QLA2340−E−SP11, 29 FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, AX100
ML370(G3)13, ML370(G4)13
275 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
Samsung: ES470, ES570, SS140 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29
276 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex: LP101−E16, 19, 44, FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X LP1050−E16, 18, 44; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 QLogic: QLA200−E−SP14, 29,
QLA210−E−SP14, 27, 29
277 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X 27, 28, 44 FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13
278 HPQ Proliant: DL380(G4)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC N1, 2
ML370(G4)13 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X (QLA2460)27, 29, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 29, AX100
111
279 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 29 FC−AL, EMC Y1, 2
Fujitsu Siemens Primergy RX800 S2; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 AX100
280 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 30 FC−AL, EMC Y1, 2
Samsung ES470 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
281 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP11, 29 FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
282 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 Adapter for HP Proliant FC−SW CLARiiON
AS/ES v2.4.21−40.EL7, 25 BL25p/BL45p 381881−B213, 29 AX100
283 Dell PowerEdge 1950 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP27, 85, 103 FC−AL, EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 Express FC−SW CLARiiON
AX100
284 Dell PowerEdge: 1850, 1900, 2850, Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP27, 85, 103 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
285 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP27, 85, 103 FC−AL, EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 Express, FC−SW CLARiiON
PCI−X AX100
286 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)21, 26, 54, 72 AX100
287 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y74
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)21, 72, 75 AX100
288 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403619−B21)24, 47, 69 AX100
289 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ: Emulex LPe1105−HP 4Gb FC−AL, EMC Y
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express FC HBA for HP c−Class FC−SW CLARiiON
(407235−B21) Bladesystem (403621−B21)21, 72, AX100
75, QLogic QMH2462 4Gb FC HBA
for HP c−Class Bladesystem
(403619−B21)47, 69
QLogic: QLA200−E−SP14,
QLA2340−E−SP11
313 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP1050−E16, 18, 27, 50 , FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 27, 50 FC−SW CLARiiON
AX100
314 Sun: V20z, V40z Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP1050−E16, 18, 27, 100 , FC−AL, EMC Y1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 27, 100 ; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP11, 27, 77
315 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP1050−E16, 18, 50, FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL760 (G2)13, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 50 FC−SW CLARiiON
DL76013, ML570(G2)13; AX100
Samsung: SS370, SS3840
316 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
6650; v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, RX600 S2, TX200
S2, TX300, TX300 S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS370, SS3840
317 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, Emulex LP101−E16, 19, 27, 100 ; FC−AL, EMC N1, 2
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 PCI−X QLogic: QLA200−E−SP14, 27, 77, FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13; QLA2340−E−SP11, 77 AX100
Samsung SS140
318 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, Emulex: LP1050−E16, 18, 27, 100 , FC−AL, EMC Y1, 2
(Model 8848) v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 PCI−X LP982−E16, 27, 100 ; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP11, 27, 77
319 HPQ Proliant:DL14513,DL380(G2)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, Emulex: LP1050−E16, 18, 50, FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 PCI−X LP982−E16, 50 FC−SW CLARiiON
DL385 , DL580(G2) , DL580(G3)13,
13 13 AX100
DL58513, ML370(G3)13, ML370(G4)13
320 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI QLogic QLA200−E−SP14, 27, 77 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
HPQ Proliant: DL32013, DL360(G2)13, v2.6.9−11.EL49
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
342 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic QLA200−E−SP14, 27, 77 FC−AL, EMC N1, 2
6600, 6650; v2.6.9−11.EL49 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, TX200 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
343 Dell PowerEdge: 6600, 6650; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
v2.6.9−11.EL49 FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, AX100
RX300, RX300 S2, TX200 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
344 Dell PowerEdge: 6600, 6650 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic: QLA200−E−SP14, FC−AL, EMC N1, 2
v2.6.9−11.EL49 QLA2340−E−SP11 FC−SW CLARiiON
AX100
345 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X67 Emulex: LP101−E16, 19, 27, 48 , FC−AL, EMC Y1, 2
v2.6.9−11.EL49 LP1050−E16, 18, 27, 48 , LP982−E16, FC−SW CLARiiON
27, 48; AX100
QLogic QLA2340−E−SP11, 27, 77
346 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y
v2.6.9−11.EL49 Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394757−B2116, 22, 23, 48 AX100
347 HPQ Proliant: BL25p, BL30p, BL35p Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y
v2.6.9−11.EL49 BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
22, 23, 48
QLogic QLA2340−E−SP11, 40
372 Dell PowerEdge: 2900, 2950; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E16, 19, 27, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LPe111−E16, 27, 43, 54 , FC−SW CLARiiON
IBM eServer 326m (Model 7969) AS/ES v2.6.9−22.0.2.EL PCI−X LPe1150−E16, 27, 42, 43 ; AX100
QLogic: QLE2360−E−SP27, 36, 37,
40, QLE2460−E−SP27, 40, 56
373 Fujitsu Siemens Primergy RX220 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E16, 27, 32, 119 , FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LPe1150−E16, 27, 43, 118 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X AX100
374 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP101−E16, 19, 27, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LP1050−E16, 18, 43, LP982−E16, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X 67 AX100
QLogic: QLA200−E−SP14, 27, 40,
QLA210−E−SP14, 27, 40,
QLA2340−E−SP11, 40
375 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Dell: 2342M11, 2342M11, 40, FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LPe1105−M16, 27, 42, 43 , FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL QME246227, 40, 41 AX100
376 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLogic QLA200−E−SP14, 27, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
377 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E16, 19, 43; FC−AL, EMC Y1, 39
6650 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLogic QLA200−E−SP14, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
378 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050−E16, 18, 27, 43 FC−AL, EMC Y1, 39
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
383 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (QLA2460)27, 40, 111 , FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AE369A/FC1243 (QLA2462)27, 40, AX100
111
384 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y1, 39
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ 35, 43 FC−SW CLARiiON
140Rd−4 AS/ES v2.6.9−22.0.2.EL AX100
385 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 35, FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ 43, 68 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
386 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 40 FC−AL, EMC Y1, 39
1850, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
387 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 27, 40 FC−AL, EMC Y1, 39
1850, 1950; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
388 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 40 FC−AL, EMC Y1, 39
6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
389 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2460−E−SP27, 40, 56 FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
390 Fujitsu Siemens Primergy: RX300 S2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic: QLA200−E−SP14, 27, 40, FC−AL, EMC Y
TX200 S2, TX300 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLA210−E−SP14, 27, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
393 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X83 Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
x3950/x3950E/x460 (8872, 8874)81, 82 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP982−E16, 27, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
QLogic QLA2340−E−SP11, 27, 40
394 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 42, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, QME246227, 40, 41 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X AX100
395 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X QLogic: QLA200−E−SP14, 27, 40, FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−22.0.2.EL QLA210−E−SP14, 27, 40 AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung SS140
396 Fujitsu Siemens Primergy: RX600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex LP1050−E16, 27, 32, 43 FC−AL, EMC Y
RX800 S2, TX600 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
397 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
2850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X LP982−E16, 27, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
IBM eServer: 325 (Model 8835), 326 QLogic QLA2340−E−SP11, 27, 40
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
398 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex: LP1050−E16, 18, 43, FC−AL, EMC Y1, 39
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X LP982−E16, 43 FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−22.0.2.EL AX100
DL58513, ML370(G3)13, ML370(G4)13
399 Fujitsu Siemens Primergy: RX600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Fujitsu Siemens FC−AL, EMC Y
RX800, TX600 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X S26361−F2843−E1 (Emulex FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL LP9802)16, 32, 43 AX100
400 HPQ Proliant: DL380(G4)13, DL38513, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y1, 39
DL58513, ML370(G4)13 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X (QLA2460)27, 40, 111 , FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AE369A/FC1243 (QLA2462)27, 40, AX100
111
401 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, IBM 24P0960 (QLA2340)11, 27, 40, FC−AL, EMC Y1, 39
(Model 8848) v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X 66 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
402 Fujitsu Siemens Primergy RX800 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 115 FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
403 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic QLA2340−E−SP11, 40 FC−AL, EMC Y1, 39
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13; AS/ES v2.6.9−22.0.2.EL AX100
Samsung SS140
404 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic: QLA2340−E−SP11, 27, 40, FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X QLA2340−E−SP11, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
405 Fujitsu Siemens Primergy: RX300 S2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex: LP101−E16, 27, 32, FC−AL, EMC Y
TX200 S2, TX300 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP101−E16, 32, LP1050−E16, 27, 32; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, AX100
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Fujitsu Siemens
v2.6.9−34.0.2.EL S26361−F2843−E1 (Emulex
LP9802)16, 32;
QLogic QLA2340−E−SP11
406 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, Express QLogic QLE2360−E−SP36, 37, 40 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230
407 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP101−E16, 19, 43, FC−AL, EMC Y1, 39
v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, Express LP1050−E16, 18, 43, LP982−E16, 27, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL 43, LP982−E16, 43; AX100
QLogic QLA2340−E−SP11, 40
408 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LPe111−E16, 27, 43, 54 , FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, Express LPe1150−E16, 27, 42, 64 ; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF520; QLogic: QLE2360−E−SP27, 36, 37,
40, QLE2460−E−SP27, 40, 56
Samsung ZSS230
409 LangChao: NC3000, NC3500, NF500, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050−E16, 18, 27, 43 ; FC−AL, EMC Y1, 39
NF520; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP11, 27, 40 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
Samsung ZSS230
410 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP982−E16, 27, 43 FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230
440 IBM xSeries: x3550 (7978), x3650 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI IBM: 24P0960 (QLA2340)11, 27, 66, FC−AL, EMC Y
(7979) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, 80, 24P8053 (QLA2342)11, 27, 80, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X 39M5894 (QLA2460)27, 39M5895 AX100
(QLA2462)27;
QLogic: QLA2460−E−SP27, 56, 80,
QLE2360−E−SP27, 80, 98,
QLE2460−E−SP27, 80, 97
441 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI NEC: N8190−120 (LP1050)18, 35, FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, 116, 120, N8190−127 (LPe1150)35, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X 42, 116, 120 AX100
442 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP11, 27, 80 FC−AL, EMC Y
6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy: RX220,
RX600 S3, TX600 S3;
IBM xSeries: x3550 (7978), x3650
(7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
443 Fujitsu Siemens Primergy: RX220, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP11, 80 FC−AL, EMC Y
RX600 S3, TX600 S3; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
HPQ Proliant ML350(G4)13
444 Dell PowerEdge: 1850, 1900, 2850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP27, 85, 102 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
445 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP101−E16, 19, 27, 53 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, LP1050−E16, 18, 53, LP982−E16, 53; FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X 67 AX100
QLogic: QLA200−E−SP14, 27, 80,
QLA210−E−SP14, 27, 80,
QLA2340−E−SP11, 80,
QLE220−E−SP27, 85, 102, 108
446 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Dell: 2342M11, 80, LPe1105−M16, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 27, 42, 53 , QME246227, 41, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
447 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ QLogic QLA200−E−SP14, 27, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
448 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E16, 19, 53 FC−AL, EMC Y
6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
LangChao: NC3000, NC3500, NF500,
NF520
449 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP1050−E16, 18, 27, 53 FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
456 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(416654−B21), (416655−B21), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); AS/ES v2.6.9−34.0.2.EL (403619−B21)69, 101 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
457 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (QLA2460)27, 111, 112 , FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AE369A/FC1243 (QLA2462) 27, 101, AX100
111
458 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 35, 53 FC−SW CLARiiON
140Rd−4 AS/ES v2.6.9−34.0.2.EL AX100
459 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 35, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 53, 68 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
460 Fujitsu Siemens Primergy: RX300 S2, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP14, 27 FC−AL, EMC Y
TX200 S2, TX300 S2 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
461 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP14, 80 FC−AL, EMC Y
6650 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
462 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 80 FC−AL, EMC Y
1850, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
Fujitsu Siemens Primergy: RX300 S2,
TX200 S2, TX300 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
469 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 42, 53 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, QME246227, 41, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
470 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, PCI QLogic QLE220−E−SP27, 85, 102 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
471 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X QLogic: QLA200−E−SP14, 27, 80, FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−34.0.2.EL QLA210−E−SP14, 27, 80, AX100
DL58513, ML370(G3)13, ML370(G4)13; QLE220−E−SP27, 85, 102, 108
Samsung SS140
472 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP1050−E16, 27, 32, 53 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
473 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E16, 18, 27, 53 , FC−AL, EMC Y
2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X LP982−E16, 27, 53 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
IBM eServer: 325 (Model 8835), 326
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
474 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E16, 18, 53, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X LP982−E16, 53; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−34.0.2.EL AX100
DL58513, ML370(G3)13, ML370(G4)13 HPQ AD167A/FC2143 (LP1150)16,
27, 28, 53
475 HPQ Proliant: DL380(G4)13, DL38513, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
DL58513, ML370(G4)13 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X (QLA2460)27, 111, 112 , FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AE369A/FC1243 (QLA2462)27, 101, AX100
111
494 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ: Emulex LPe1105−HP 4Gb FC−AL, EMC Y
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC HBA for HP c−Class FC−SW CLARiiON
(416655−B21), (416656−B21), Bladesystem (403621−B21)21, 72, AX100
(432636−B21); 75, QLogic QMH2462 4Gb FC HBA
for HP c−Class Bladesystem
HPQ Proliant BL465c: (403433−B21), (403619−B21)47, 69
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
495 IBM xSeries x3455 (7984) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI IBM: 42C2069 (LPe11000)16, 21, 27, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express 68,42C2071 (LPe11002)16, 21, 27, FC−SW CLARiiON
42; AX100
QLogic: QLE2360−E−SP27, 37, 47,
QLE2362−E−SP27, 37, 47,
QLE2462−E−SP27, 47, 56
496 Dell PowerEdge 1950; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
497 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP27, 36, 37, FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express 47 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
498 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP36, 37, 47 FC−AL, EMC Y
HR−6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230
499 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2460−E−SP27, 47, 56 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
QLogic QLA2340−E−SP11, 47
504 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050Ex−E16, 19, 21, 27 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LPe111−E16, 21, 27, 54 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X LPe1150−E16, 21, 27, 42 ; AX100
AS2500;
QLogic: QLE2360−E−SP27, 36, 37,
Intel: SR1500/S5000PAL, 47, QLE2460−E−SP27, 47, 56
SR2500/S5000PAL
505 IBM xSeries: x3550 (7978), x3650 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI IBM: 24P0960 (QLA2340)11, 27, 47, FC−AL, EMC Y
(7979), x3755 (8877) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, 66, 24P8053 (QLA2342)11, 27, 47; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA2460−E−SP27, 47, 56,
QLE2360−E−SP27, 47, 98,
QLE2460−E−SP27, 47, 97
506 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI NEC: N8190−120 (LP1050)18, 21, FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, 35, 116, N8190−127 (LPe1150)21, FC−SW CLARiiON
PCI−X 35, 42, 116 AX100
507 Dell PowerEdge: 1850, 1900, 2850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
HPQ Proliant ML350(G4)13;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
508 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP101−E16, 19, 21, 27 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP1050−E16, 18, 21, LP982−E16, 21; FC−SW CLARiiON
PCI−X 67 AX100
QLogic: QLA200−E−SP14, 27, 47,
QLA210−E−SP14, 27, 47,
QLA2340−E−SP11, 47,
QLE220−E−SP27, 84, 85
509 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Dell: 2342M11, 47, LPe1105−M16, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 27, 42 , QME246227, 41, 47 FC−SW CLARiiON
AX100
510 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E16, 19, 21 FC−AL, EMC Y
6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
LangChao: NC3000, NC3500, NF500,
NF520
511 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL QLogic QLA200−E−SP14, 27, 47 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
517 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (QLA2460)27, 47, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 47, AX100
111
518 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 35 FC−SW CLARiiON
140Rd−4 AX100
519 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 21, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 35, 68 FC−SW CLARiiON
AX100
520 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA200−E−SP14, 47 FC−AL, EMC Y
6650 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
521 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 47 FC−AL, EMC Y
1850, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
528 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI Dell: LPe1105−M16, 21, 27, 42 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, QME246227, 41, 47 FC−SW CLARiiON
PCI−X AX100
529 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI Emulex: LP101−E16, 19, 21, 27 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP1050−E16, 18, 21, LP982−E16, 21, FC−SW CLARiiON
PCI−X LPe111−E16, 21, 27, 54 , AX100
LPe1150−E16, 21, 27, 42 ;
HPQ: A8002A/FC2142SR
(LPe1150)16, 21, 27, 68 ,
AD167A/FC2143 (LP1150)16, 21, 27,
28, AE311A/FC1142SR
(QLE2460)27, 47, 56,
AE312A/FC1242SR (QLE2462)27,
47, 56;
531 Dell PowerEdge: 1800, 2800; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) PCI−X AX100
532 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLA200−E−SP14, 27, 47, FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, QLA210−E−SP14, 27, 47, AX100
DL58513, ML370(G3)13, ML370(G4)13; QLE220−E−SP27, 84, 85
Samsung SS140
533 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E16, 18, 21, 27 , FC−AL, EMC Y
2850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X LP982−E16, 21, 27; FC−SW CLARiiON
AX100
IBM eServer: 325 (Model 8835), 326 QLogic QLA2340−E−SP11, 27, 47
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
535 HPQ Proliant: DL380(G4)13, DL38513, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
DL58513, ML370(G4)13 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X (QLA2460)27, 47, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 47, AX100
111
536 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, IBM 24P0960 (QLA2340)11, 27, 47, FC−AL, EMC Y
(Model 8848) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X 66 FC−SW CLARiiON
AX100
537 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, QLogic QLA2340−E−SP11, 47 FC−AL, EMC Y
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13; AX100
Samsung SS140
538 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X), 8843) v2.4.21−20.EL7 (13N2203)11, 38, 73 CLARiiON
AX100
539 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
v2.4.21−20.EL7 (26K4841)11, 27, 38, 73 CLARiiON
AX100
540 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X), 8843) v2.4.21−27.0.1.EL7, 8 (13N2203)4, 11, 38, 73 CLARiiON
AX100
541 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X IBM HS20 FC Exp Card FC−SW EMC Y1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; (26K4841)11, 12, 27, 38 CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
542 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; (13N2203)11, 12, 27, 38 , CLARiiON
(48P7061)11, 12, 27, 38 AX100
IBM BladeCenter HS40 (Model 8839) Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
543 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−40.EL7, 25 Dual port: for NovaScale Blade CLARiiON
Series CFSN202−110030, 86, 108 , AX100
mini for NovaScale Blade 2021
CFSN202−210030, 86, 108 ;
Bull: SBEFCM (SFF) Mezzanine
HBA30, 86, 108 , SBEFCM4 (SFF)
4Gb Mezzanine HBA30, 57, 108
544 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Digital Henge Digital Henge: FC−SW EMC Y
v2.4.21−40.EL7, 25 SBEFCM427, 30, 57, SBEFCM30, 86, CLARiiON
108, SBFCM30, 86, 108 ; AX100
Digital Henge Intel (r) Fibre
Channel Module AHWFCMOD27,
30, 105, 108
545 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre FC−SW EMC Y
8843); v2.4.21−40.EL7, 25 Channel Exp Card (39Y9186)27, 31, CLARiiON
70, 71 AX100
IBM BladeCenter LS20 (Model 8850)
546 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
LS20 (Model 8850) v2.4.21−40.EL7, 25 (26R0890)27, 29, 57 CLARiiON
AX100
547 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y
v2.4.21−40.EL7, 25 (26K4841)11, 27, 29 CLARiiON
AX100
548 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−40.EL7, 25 (13N2203)11, 27, 29, (48P7061)11, CLARiiON
27, 29 AX100
IBM BladeCenter HS40 (Model 8839)
549 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.4.21−40.EL7, 25 for IBM eServer LS2011, 27, 29, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 29
550 IBM BladeCenter HS21 (Model 8853)99 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre FC−SW EMC Y96
v2.4.21−40.EL7, 25 Channel Exp Card (39Y9186)27, 31, CLARiiON
70, 114, HS20 4GB SFF FC Exp AX100
Card (26R0890)27, 29, 57, 59 , HS20
FC Exp Card (13N2203)11, 27, 29,
HS20 FC Exp Card (48P7061)11,
27, 29
551 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−40.EL7, 25 Card16, 27, 31, 52 , HS20 4GB CLARiiON
Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)27, 29, 51
LS20 (Model 8850)
552 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−47.EL7, 25 Dual port: for NovaScale Blade CLARiiON
Series CFSN202−1100105, 107, AX100
mini for NovaScale Blade 2021
CFSN202−2100105, 107, mini for
NovaScale Blade 2021
CFSN202−210086, 87;
Bull: SBEFCM (SFF) Mezzanine
HBA105, 107, SBEFCM4 (SFF) 4Gb
Mezzanine HBA106, 107
554 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre FC−SW EMC Y
8843); v2.4.21−47.EL7, 25 Channel Exp Card (39Y9186)26, 27, CLARiiON
70, 71 AX100
IBM BladeCenter: LS20 (Model 8850),
LS21 (Model 7971), LS41 (Model 7972)
555 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−47.EL7, 25 (13N2203)11, 24, 27, (48P7061)11, CLARiiON
24, 27 AX100
IBM BladeCenter HS40 (Model 8839)
556 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.4.21−47.EL7, 25 for IBM eServer LS2011, 24, 27, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 24, 27
557 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y
LS20 (Model 8850), LS21 (Model 7971), v2.4.21−47.EL7, 25 (26R0890)24, 27, 57, FC Exp Card CLARiiON
LS41 (Model 7972) (26K4841)11, 24, 27 AX100
558 IBM BladeCenter HS21 (Model 8853)99 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre FC−SW EMC Y96
v2.4.21−47.EL7, 25 Channel Exp Card (39Y9186)26, 27, CLARiiON
70, 114, HS20 4GB SFF FC Exp AX100
Card (26R0890)24, 27, 57, 59 , HS20
FC Exp Card (13N2203)11, 24, 27,
HS20 FC Exp Card (48P7061)11,
24, 27
559 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−47.EL7, 25 Card16, 26, 27, 52 , HS20 4GB CLARiiON
Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)24, 27, 51
LS20 (Model 8850)
560 IBM BladeCenter HS20 (Model Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X) v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, (13N2203)11, 38, 73 CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
561 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7 (26K4841)11, 27, 38, 65, 73 CLARiiON
AX100
562 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, (26K4841)4, 11, 27, 38, 73 CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
563 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X), 8832−N1X)95, 8843) v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.2.EL7, 8, (13N2203)4, 11, 38, 73 CLARiiON
U4+ AS/ES v2.4.21−27.0.4.EL7, 8 AX100
564 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM Emulex LP1005DC FC Exp FC−SW EMC Y1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Card16, 27, 44, 52 CLARiiON
AX100
IBM BladeCenter: HS40 (Model 8839),
LS20 (Model 8850)
565 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC N1, 2
LS20 (Model 8850) v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (26R0890)27, 29, 57 CLARiiON
AX100
566 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 4GB Standard FC Exp FC−SW EMC N1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Card (26R0884)27, 29, 51 CLARiiON
AX100
IBM BladeCenter: HS40 (Model 8839),
LS20 (Model 8850)
567 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (26K4841)11, 27, 29 CLARiiON
AX100
568 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (13N2203)11, 27, 29, (48P7061)11, CLARiiON
27, 29 AX100
IBM BladeCenter HS40 (Model 8839)
569 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL for IBM eServer LS2011, 27, 29, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 29
570 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL; Dual port for NovaScale Blade CLARiiON
Series: CFSN202−110086, 87, 88, AX100
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES 89, CFSN202−110086, 87, 88, 89, 90 ,
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ CFSN202−110086, 87, 91, 92 ;
AS/ES v2.6.9−22.0.2.EL
Bull 2Gbps FC Mezzanine Card −
Dual port mini for NovaScale Blade
2021: CFSN202−210086, 87, 88, 89 ,
CFSN202−210086, 87, 88, 89, 90 ,
CFSN202−210086, 87, 91, 92 ;
Bull SBEFCM (SFF) Mezzanine:
HBA27, 86, 87, 88, 89 , HBA27, 86, 87,
88, 89, 90 , HBA27, 86, 87, 91, 92
571 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull SBEFCM (SFF) Mezzanine FC−SW EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 HBA27, 86, 87 CLARiiON
AX100
579 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
HS21 (Model 8853)99 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (26R0890)27, 57, 59, 80 CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
580 IBM BladeCenter: HS21 (Model Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)99, LS20 (Model 8850) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (26R0890)27, 57, 80 CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
581 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (26K4841)11, 27, 80 CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
582 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (13N2203)11, 27, 80, (48P7061)11, CLARiiON
AS/ES v2.6.9−34.0.2.EL 27, 80 AX100
IBM BladeCenter: HS21 (Model
8853)99, HS40 (Model 8839)
583 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ for IBM eServer LS2011, 27, 80, SFF CLARiiON
AS/ES v2.6.9−34.0.2.EL Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 80
584 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Card16, 27, 52, 53 , HS20 4GB CLARiiON
AS/ES v2.6.9−34.0.2.EL Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)27, 51, 80
LS20 (Model 8850)
585 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Dual port for NovaScale Blade CLARiiON
Series: CFSN202−110047, 105, AX100
CFSN202−110047, 86;
Bull 2Gbps FC Mezzanine Card −
Dual port mini for NovaScale Blade
2021: CFSN202−210047, 105,
CFSN202−210047, 86;
Bull SBEFCM (SFF) Mezzanine:
HBA27, 47, 86, HBA47, 105;
Bull SBEFCM4 (SFF) 4Gb
Mezzanine HBA47, 106
586 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Digital Henge Digital Henge: FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL SBEFCM427, 47, 106 , SBEFCM47, CLARiiON
105, SBFCM47, 105; AX100
Digital Henge Intel (r) Fibre
Channel Module AHWFCMOD27,
47, 105
587 IBM BladeCenter: HS21 (Model Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)99, LS20 (Model 8850), LS21 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (26R0890)27, 47, 57 CLARiiON
(Model 7971), LS41 (Model 7972) AX100
588 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
HS21 (Model 8853)99 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (26R0890)27, 47, 57, 59 CLARiiON
AX100
9 IBM xSeries x3755 Red Hat RHEL [AMD−64] 3.0 U8 PCI Emulex: LP1050−E1, 2, 4, 39, LP1050Ex−E2, 4, 18, 39 ; FC−AL, EMC Y60
(8877) AS/ES v2.4.21−47.EL24, 25 Express, FC−SW CLARiiON
PCI−X IBM: 24P0960 (QLA2340)2, 7, 36, 43 , 24P8053 (QLA2342)2, 7, 43, AX100
39M5894 (QLA2460)2, 32, 43, 39M5895 (QLA2462)2, 32, 43;
QLogic: QLA2340−E−SP2, 7, 43, QLA2460−E−SP2, 32, 43,
QLE2360−E−SP2, 42, 43, QLE2460−E−SP2, 32, 43
10 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0 U8 PCI−X Emulex: LP101−E2, 4, 18, 39 , LP1050−E1, 2, 4, 39, LP982−E2, 4, 39; FC−AL, EMC Y
x4100, x4200 AS/ES v2.4.21−47.EL24, 25 FC−SW CLARiiON
QLogic: QLA200−E−SP2, 15, 43, QLA210−E−SP2, 15, 43, AX100
QLA2340−E−SP7, 43, QLE220−E−SP2, 55, 56
11 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0 U8 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y
AS/ES v2.4.21−47.EL24, 25 BL25p/BL45p 381881−B2140, 43, Emulex−based BL25/30/35/45p FC−SW CLARiiON
Fibre Channel Mezzanine HBA − 394588−B214, 39, 46, 47 AX100
12 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 3.0 U8 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.4.21−47.EL24, 25 HBA − 394588−B214, 39, 46, 47 FC−SW CLARiiON
AX100
13 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0 U8 PCI, Emulex: LP101−E2, 4, 18, 39 , LP1050−E1, 4, 39, LP982−E4, 39; FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.4.21−47.EL24, 25 PCI−X FC−SW CLARiiON
DL58521 HPQ AD167A/FC2143 (LP1150)2, 4, 39, 45 ; AX100
QLogic: QLA200−E−SP2, 15, 43, QLA210−E−SP2, 15, 43,
QLA2340−E−SP7, 43, QLE220−E−SP2, 55, 56
14 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: U4+ PCI−X HPQ Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC N6, 11
AS/ES v2.4.21−27.0.4.EL24, 64, U5 381881−B2140, 62, 63 FC−SW CLARiiON
AS/ES v2.4.21−32.EL24, 64, U5+ AX100
AS/ES v2.4.21−32.0.1.EL24, 64
15 IBM eServer 326m Red Hat RHEL [AMD−64] 3.0: U6 PCI Emulex: LP1050Ex−E2, 4, 18, 19 , LPe111−E2, 4, 13, 19 , LPe1150−E2, FC−AL, EMC Y6, 11
(Model 7969) AS/ES v2.4.21−37.EL, U6+ AS/ES Express, 4, 19, 33; FC−SW CLARiiON
v2.4.21−37.0.1.EL PCI−X AX100
QLogic: QLE2360−E−SP2, 10, 41, 42 , QLE2460−E−SP2, 10, 32
16 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0: U6 PCI−X Emulex: LP101−E2, 4, 18, 19 , LP1050−E1, 2, 4, 19, LP982−E2, 4, 19; FC−AL, EMC N6, 11
x4100, x4200 AS/ES v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL QLogic: QLA200−E−SP2, 10, 15, QLA210−E−SP2, 10, 15, AX100
QLA2340−E−SP7, 10
17 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: U6 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y6, 11
AS/ES v2.4.21−37.EL, U6+ AS/ES BL25p/BL45p 381881−B2110, 40, Emulex−based BL25/30/35/45p FC−SW CLARiiON
v2.4.21−37.0.1.EL Fibre Channel Mezzanine HBA − 394588−B214, 19, 46, 47 AX100
18 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 3.0: U6 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.4.21−37.EL, U6+ AS/ES HBA − 394588−B214, 19, 46, 47 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX100
19 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0: U6 PCI, Emulex: LP101−E2, 4, 18, 19 , LP1050−E1, 4, 19, LP982−E4, 19; FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.4.21−37.0.1.EL QLogic: QLA200−E−SP2, 10, 15, QLA210−E−SP2, 10, 15, AX100
QLA2340−E−SP7, 10
20 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0: U6 PCI, HPQ AD167A/FC2143 (LP1150)2, 4, 19, 45 FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.4.21−37.0.1.EL AX100
21 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0: U7 PCI QLogic QLE220−E−SP2, 29, 59 FC−AL, EMC Y
AS/ES v2.4.21−40.EL24, 25, U8 Express, FC−SW CLARiiON
AS/ES v2.4.21−47.EL24, 25 PCI−X AX100
22 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 PCI−X Emulex: LP1050−E1, 2, 4, 20, LP982−E2, 4, 20 FC−AL, EMC Y6, 11
AS/ES: v2.6.9−5.0.5.EL22, FC−SW CLARiiON
v2.6.9−5.EL22 AX100
23 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP101−E2, 4, 18, 20 , LP1050−E1, 4, 58, LP982−E4, 58 FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES: v2.6.9−5.0.5.EL22, PCI−X FC−SW CLARiiON
DL58521 v2.6.9−5.EL22 AX100
24 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP1050−E1, 2, 4, 20, LP982−E2, 4, 20 FC−AL, EMC Y6, 11
(Model 8835), 326 AS/ES: v2.6.9−5.0.5.EL22, PCI−X FC−SW CLARiiON
(Model 8848) v2.6.9−5.EL22 AX100
25 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 PCI−X QLogic QLA2340−E−SP2, 7, 23 FC−AL, EMC Y6, 11
AS/ES: v2.6.9−5.0.5.EL22, FC−SW CLARiiON
v2.6.9−5.EL22; AX100
Red Hat RHEL [AMD−64] 4.0 U1
AS/ES v2.6.9−11.EL22
26 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0 PCI, IBM 24P0960 (QLA2340)2, 7, 23, 36 ; FC−AL, EMC Y6, 11
(Model 8835), 326 AS/ES: v2.6.9−5.0.5.EL22, PCI−X QLogic QLA2340−E−SP2, 7, 23 FC−SW CLARiiON
(Model 8848) v2.6.9−5.EL22; AX100
Red Hat RHEL [AMD−64] 4.0 U1
AS/ES v2.6.9−11.EL22
27 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 PCI, QLogic: QLA200−E−SP2, 15, 23, QLA2340−E−SP7, 23 FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES: v2.6.9−5.0.5.EL22, PCI−X FC−SW CLARiiON
DL58521 v2.6.9−5.EL22; AX100
Red Hat RHEL [AMD−64] 4.0 U1
AS/ES v2.6.9−11.EL22
43 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: U3 PCI−X Emulex: LP1050−E1, 2, 4, 14, LP982−E2, 4, 14; FC−AL, EMC Y
x4100, x4200 AS/ES v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA2340−E−SP2, 7, 16 AX100
v2.6.9−34.0.2.EL
44 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 4.0: U3 PCI−X HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
AS/ES v2.6.9−34.EL, U3+ AS/ES HBA − 394588−B214, 14, 46, 47 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL
45 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: U3 PCI−X QLogic QLA2460−E−SP2, 16, 32 FC−AL, EMC Y
AS/ES v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL
46 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 4.0: U3 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.6.9−34.EL, U3+ AS/ES HBA − 394588−B214, 14, 46, 47 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL
47 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: U3 PCI, Emulex: LP101−E2, 4, 14, 18 , LP1050−E1, 4, 14, LP982−E4, 14; FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.6.9−34.0.1.EL, U3+ AS/ES HPQ AD167A/FC2143 (LP1150)2, 4, 14, 45 ; AX100
v2.6.9−34.0.2.EL QLogic: QLA200−E−SP2, 15, 16, QLA210−E−SP2, 15, 16,
QLE220−E−SP2, 28, 29, 30
48 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: U3 PCI, Emulex: LP1050−E1, 2, 4, 14, LP982−E2, 4, 14; FC−AL, EMC Y
(Model 8835), 326 AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
(Model 8848) v2.6.9−34.0.1.EL, U3+ AS/ES IBM 24P0960 (QLA2340)2, 7, 16, 36 AX100
v2.6.9−34.0.2.EL
49 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: U3 PCI, QLogic QLA2340−E−SP2, 7, 16 FC−AL, EMC Y
Primergy RX800 S2; AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
IBM eServer: 325 v2.6.9−34.0.1.EL, U3+ AS/ES AX100
(Model 8835), 326 v2.6.9−34.0.2.EL
(Model 8848)
7 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI Emulex: LP101−E2, 4, 7, 45, LP1050−E2, 4, 8, FC−AL, EMC Y
2950; 26 Express, 45, LP1050Ex−E2, 4, 7, 45, LP982−E2, 4, 45, FC−SW CLARiiON
PCI−X LPe111−E2, 4, 39, 45 , LPe1150−E2, 4, 41, 45 ; AX100
Digital Henge Revo:
AS1500, AS1550, QLogic: QLA200−E−SP2, 6, 44,
AS2500; QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27,
QLE2360−E−SP2, 27, 42, 43 ,
Intel: SR1500/S5000PAL, QLE2460−E−SP2, 27, 53
SR2500/S5000PAL
8 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Dell 2342M9, 27 FC−AL, EMC Y
Unisys ES3105 26 FC−SW CLARiiON
AX100
9 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Dell: LPe1105−M2, 4, 41, 45 , QME24622, 27, FC−AL, EMC Y
26 56 FC−SW CLARiiON
AX100
32 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI NEC: N8190−120 (LP1050)8, 16, 40, 75 , FC−AL, EMC Y
120Li, 120Rg−1, 26 Express, N8190−127 (LPe1150)16, 40, 41, 75 FC−SW CLARiiON
120Ri−2, 140Hf, PCI−X AX100
140Re−4
33 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Dell 2342M9, 72 FC−AL, EMC Y
Unisys ES3105 26 FC−SW CLARiiON
AX100
34 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Dell: LPe1105−M2, 4, 40, 41 , QME24622, 56, FC−AL, EMC Y
26 72 FC−SW CLARiiON
AX100
35 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Emulex LP982−E2, 4, 40 FC−AL, EMC Y
1850, 2600, 2650, 2850; 26 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
36 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Emulex: LP101−E2, 4, 7, 40, LP1050−E2, 4, 8, FC−AL, EMC Y
1850, 1950, 2600, 2650, 26 40; FC−SW CLARiiON
2850; AX100
QLogic: QLA200−E−SP2, 6, 72,
Digital Henge INNO: QLA2340−E−SP2, 9, 72
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
37 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y18, 19
(416653−B21), 26 HP c−Class Bladesystem (403621−B21)39, FC−SW CLARiiON
(416654−B21), 40, 84 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
45 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, PCI Dell: LPe1105−M2, 4, 40, 41 , QME24622, 56, FC−AL, EMC Y
26 Express, 72 FC−SW CLARiiON
PCI−X AX100
46 HPQ Proliant: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, PCI Emulex: LPe111−E2, 4, 39, 40 , LPe1150−E2, FC−AL, EMC Y
DL380(G5), DL580(G4) 26 Express, 4, 40, 41; FC−SW CLARiiON
PCI−X AX100
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4,
40, AD167A/FC2143 (LP1150)2, 4, 29, 40 ,
AE311A/FC1142SR (QLE2460)2, 53, 72,
AE312A/FC1242SR (QLE2462)2, 53, 72
47 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, Emulex: LP101−E2, 4, 7, 40, LP1050−E2, 4, 8, FC−AL, EMC Y
Samsung: ES470, 26 PCI−X 40, LP982−E2, 4, 40; FC−SW CLARiiON
ES570, SS140 AX100
QLogic: QLA200−E−SP2, 6, 72,
QLA210−E−SP2, 6, 72, QLA2340−E−SP2, 9,
72
48 Samsung: ES470, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, QLogic QLE220−E−SP2, 76, 77 FC−AL, EMC Y
ES570, SS140 26 PCI−X FC−SW CLARiiON
AX100
49 NEC Express 5800 Red Hat RHEL [EM64T] 3.0: U3 AS/ES PCI NEC N8190−120 (LP1050)4, 7, 16, 81 FC−AL, EMC N19, 48
110Rg−1 v2.4.21−20.EL25, U4 AS/ES v2.4.21−27.EL25, 62, U4+ Express, FC−SW CLARiiON
AS/ES v2.4.21−27.0.1.EL25, 62, U4+ AS/ES PCI−X AX100
v2.4.21−27.0.2.EL25, 62, U4+ AS/ES
v2.4.21−27.0.4.EL25, 62
52 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U4 AS/ES PCI−X Dell 2342M9, 92 FC−AL, EMC N19, 48
v2.4.21−27.EL25, 62, U4+ AS/ES v2.4.21−27.0.1.EL25, FC−SW CLARiiON
62,U4+ AS/ES v2.4.21−27.0.2.EL25, 62, U4+ AS/ES AX100
v2.4.21−27.0.4.EL25, 62, U5 AS/ES v2.4.21−32.EL25, 62,
U5+ AS/ES v2.4.21−32.0.1.EL25, 62
53 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI NEC N8190−120: (LP1050)4, 7, 16, 61 , FC−AL, EMC N19, 48
120Rd−1, 140Hd, v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, (LP1050)4, 7, 16, 63, 64 FC−SW CLARiiON
140Rc−4, 180Rd−4 62 AX100
54 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex LP1050Ex−E2, 4, 7, 57; FC−AL, EMC Y19, 48
1850, 2800, 2850; v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, Express QLogic QLE2360−E−SP2, 27, 42, 43 FC−SW CLARiiON
62 AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
55 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
1850, 2800, 2850; v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, Express, 71; FC−SW CLARiiON
62 PCI−X AX100
LangChao: NC3000, QLogic QLA200−E−SP2, 6, 69, 70
NC3500, NF500, NF520
56 Dell PowerEdge: 2600, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
2650; v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, 71; FC−SW CLARiiON
62 AX100
Digital Henge SH4500R4; QLogic QLA200−E−SP2, 6, 69, 70
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS370,
SS3840, ZSS150,
ZSS230
57 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X22 Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
(8865)20, 21, v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, 71; FC−SW CLARiiON
x3950/x3950E/x460 62 AX100
(8872, 8874)20, 21 QLogic QLA200−E−SP2, 6, 69, 70
58 Samsung: ES470, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI, Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
ES570, SS140 v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, PCI−X 71; FC−SW CLARiiON
62 AX100
QLogic QLA200−E−SP2, 6, 69, 70
59 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI Fujitsu Siemens BX600−FC22Q2, 9, 11, 27 FC−AL, EMC N19, 48
BX620: S2F46, S246 U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
60 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI Emulex LP1050Ex−E2, 4, 7, 57; FC−AL, EMC Y19, 48
1850, 1950, 2800, 2850; U6+ AS/ES v2.4.21−37.0.1.EL Express QLogic QLE2360−E−SP2, 27, 42, 43 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
73 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X31 Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
JS1400, JS2400 U6+ AS/ES v2.4.21−37.0.1.EL 57, LP982−E2, 4, 57; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27
74 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, PCI Dell: LPe1105−M2, 4, 41, 57 , QME24622, 27, FC−AL, EMC N19, 48
U6+ AS/ES v2.4.21−37.0.1.EL Express, 56 FC−SW CLARiiON
PCI−X AX100
75 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
Samsung: ES470, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X 57, LP982−E2, 4, 57; FC−SW CLARiiON
ES570, SS140 AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27
76 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, QLogic QLA2340−E−SP2, 9, 27 FC−AL, EMC Y19, 48
Samsung: ES570, SS140 U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
77 Samsung ES470 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, QLogic QLA2340−E−SP2, 9, 44 FC−AL, EMC Y19, 48
U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
78 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP2, 33, 54 FC−AL, EMC Y
v2.4.21−40.EL25, 26, U8 AS/ES v2.4.21−47.EL25, 26 Express FC−SW CLARiiON
AX100
79 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP2, 33, 54 FC−AL, EMC Y
1900, 2850, 2900, 2950; v2.4.21−40.EL25, 26, U8 AS/ES v2.4.21−47.EL25, 26 Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
80 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP2, 33, 54 FC−AL, EMC Y
2800 v2.4.21−40.EL25, 26, U8 AS/ES v2.4.21−47.EL25, 26 Express, FC−SW CLARiiON
PCI−X AX100
81 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.0.5.EL49 PCI−X Emulex LP101−E2, 4, 7, 80 FC−AL, EMC N19, 48
HPQ Proliant FC−SW CLARiiON
DL360(G4)30; AX100
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003
82 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.0.5.EL49 PCI−X QLogic QLA200−E−SP2, 6, 50 FC−AL, EMC N19, 48
Fujitsu Siemens FC−SW CLARiiON
Primergy: RX200 S2, AX100
RX300, RX300 S2,
RX600 S2, TX200 S2,
TX300, TX300 S2, TX600
S2;
HPQ Proliant
DL360(G4)30;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003
183 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI NEC: N8190−120 (LP1050)8, 16, 74, 75 , FC−AL, EMC Y
120Li, 120Rg−1, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, N8190−127 (LPe1150)16, 41, 74, 75 FC−SW CLARiiON
120Ri−2, 140Hf, v2.6.9−34.0.2.EL PCI−X AX100
140Re−4
184 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLA2340−E−SP2, 9, 10 FC−AL, EMC Y
2950, 6800, 6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens
Primergy: RX220, RX600
S3, TX600 S3;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
185 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
Primergy: RX220, RX600 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
S3, TX600 S3; v2.6.9−34.0.2.EL PCI−X AX100
HPQ Proliant
ML350(G4)30
186 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE220−E−SP2, 33, 34 FC−AL, EMC Y
1900, 2850, 2900, 2950, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
6800, 6850; v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
187 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex: LP101−E2, 4, 7, 14, LP1050−E4, 8, FC−AL, EMC Y
JS1400, JS2400 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, 14, LP982−E4, 14; FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X31 AX100
QLogic: QLA200−E−SP2, 6, 10,
QLA210−E−SP2, 6, 10, QLA2340−E−SP9,
10, QLE220−E−SP2, 32, 33, 34
188 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Dell: 2342M9, 10, LPe1105−M2, 4, 14, 41 , FC−AL, EMC Y
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QME24622, 10, 56 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
189 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex LP101−E2, 4, 7, 14; FC−AL, EMC Y
1950; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA200−E−SP2, 6, 10 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
207 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, PCI QLogic QLE220−E−SP2, 33, 34 FC−AL, EMC Y
2800 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
208 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, Emulex LP1050−E2, 4, 14, 35 FC−AL, EMC Y
RX800 S2 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
209 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, Emulex: LP101−E2, 4, 7, 14, LP1050−E4, 8, FC−AL, EMC Y
DL380(G4)30, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X 14, LP982−E4, 14; FC−SW CLARiiON
ML370(G4)30 v2.6.9−34.0.2.EL AX100
HPQ: AB429A/FC1143 (QLA2460)2, 36, 37,
AD167A/FC2143 (LP1150)2, 4, 14, 29 ,
AE369A/FC1243 (QLA2462)2, 36, 38;
QLogic: QLA200−E−SP2, 6, 10,
QLA210−E−SP2, 6, 10, QLE220−E−SP2, 32,
33, 34
210 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, Emulex: LP1050−E2, 4, 8, 14, LP982−E2, 4, FC−AL, EMC Y
1850, 2800, 2850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X 14 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470,
ES570, SS140
211 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, QLogic QLA2340−E−SP2, 9, 10 FC−AL, EMC Y
1850, 2800, 2850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy
RX800 S2;
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470,
ES570, SS140
212 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
RX800 S2; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
HPQ Proliant: v2.6.9−34.0.2.EL AX100
DL380(G4)30,
ML370(G4) 30
213 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP101−E2, 3, 4, 7; FC−AL, EMC Y
2800, 2850, 6800, 6850; U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic: QLA200−E−SP2, 5, 6, FC−SW CLARiiON
QLA210−E−SP2, 5, 6 AX100
Digital Henge Revo:
JS1400, JS2400
214 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP1050−E2, 3, 4, 8; FC−AL, EMC Y
2800, 2850 U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic QLA2340−E−SP2, 5, 9 FC−SW CLARiiON
AX100
231 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI NEC: N8190−120 (LP1050)3, 8, 16, 75 , FC−AL, EMC Y
120Li, 120Rg−1, U4+ AS/ES v2.6.9−42.0.2.EL Express, N8190−127 (LPe1150)3, 16, 41, 75 FC−SW CLARiiON
120Ri−2, 140Hf, PCI−X AX100
140Re−4
232 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE220−E−SP2, 33, 47 FC−AL, EMC Y
1900, 2850, 2900, 2950, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
6800, 6850; PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
233 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex: LP101−E2, 3, 4, 7, LP1050−E3, 4, 8, FC−AL, EMC Y
JS1400, JS2400 U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E3, 4; FC−SW CLARiiON
PCI−X31 AX100
QLogic: QLA200−E−SP2, 5, 6,
QLA210−E−SP2, 5, 6, QLA2340−E−SP5, 9,
QLE220−E−SP2, 32, 33, 47
234 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Dell: 2342M5, 9, LPe1105−M2, 3, 4, 41, FC−AL, EMC Y
U4+ AS/ES v2.6.9−42.0.2.EL QME24622, 5, 56 FC−SW CLARiiON
AX100
29. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
31. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
32. Driver/BIOS are available at http://www.qlogic.com
33. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
34. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
35. Firmware Version 1.91a1
36. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
38. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
39. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
40. Driver Version 7.3.6 Driver is integrated into the kernel.
41. Firmware Version 2.50a6
42. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
43. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
44. Driver Version 7.07.00
45. Driver Version 7.3.3 Driver is integrated into the kernel.
46. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
47. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
48. Booting from the SAN with PowerPath is not supported.
49. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
50. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
51. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
52. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
53. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
54. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
55. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
56. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
57. Driver Version 7.3.2 Driver is integrated into the kernel.
58. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
59. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
60. BIOS 1.12
61. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
62. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file names
must be used.
63. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
64. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
65. PowerPath is not supported.
66. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
67. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
68. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
69. Driver Version 7.01.01 Driver is integrated into the kernel.
70. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
71. Driver Version 7.1.14 Driver is integrated into the kernel.
72. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
73. This HBA is equivalent to the QLogic QLA2340.
74. Driver Version 8.0.16.18
75. BIOS 1.70a3
76. BIOS 1.02
77. Driver Version 7.07.05
78. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
79. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
80. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
81. Driver Version 7.1.14
82. BIOS 1.16
83. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
84. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
85. Driver Version 8.01.00
86. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
87. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
88. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
89. Driver Version 8.0.16.6_x2−2 The Emulex 8.0.16.6_x2−2 package supersedes the Emulex 8.0.16.6_x2−1 package.
90. Firmware Version 2.50a8
91. Firmware Version 2.50a8 Driver is integrated into the kernel.
92. Driver Version 7.04.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
93. Driver Version 7.03.00 Driver is integrated into the kernel.
14 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 106, 19, PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(407234−B21), (407235−B21) 20, 24, 25 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(403621−B21)21, 22, 76, QLogic AX100
QMH2462 4Gb FC HBA for HP
c−Class Bladesystem
(403619−B21)46, 75
15 Dell PowerEdge 1950 SuSE SLES [32−Bit] 106, 19, PCI QLogic QLE220−E−SP4, 16, 58 FC−AL, EMC Y
20, 24, 25 Express FC−SW CLARiiON
AX100
16 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 106, 19, PCI QLogic QLE2460−E−SP4, 32, 52 FC−AL, EMC Y
6850 20, 24, 25 Express FC−SW CLARiiON
AX100
17 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex LP101−E4, 9, 10, 27 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
HPQ Proliant ML350(G4)45;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
18 Fujitsu Siemens Primergy TX300 S3 SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050Ex−E4, 10, 12, 27 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
19 Fujitsu Siemens Primergy: RX600 S3, TX600 S3 SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050Ex−E4, 10, 27, 92 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
20 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex LPe1150−E4, 10, 27, 28 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
Fujitsu Siemens Primergy: RX200 S3, RX600 S3, TX300
S3, TX600 S3;
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
21 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050−E4, 10, 27, 29 , FC−AL, EMC Y
20, 24, 25 Express, LP982−E4, 10, 27; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
QLogic QLA2340−E−SP4, 35, 52
Intel: SR1500/S5000PAL, SR2500/S5000PAL
22 HPQ Proliant ML350(G4)45 SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050−E10, 27, 29, FC−AL, EMC Y
20, 24, 25 Express, LP982−E10, 27; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)4,
44, 52, AD167A/FC2143 (LP1150)4,
10, 27, 60 ;
33 HPQ Proliant DL360(G4)45 SuSE SLES [32−Bit] 106, 19, PCI−X HPQ AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y
20, 24, 25 44, 52 FC−SW CLARiiON
AX100
34 Dell PowerEdge: 1600SC, 1650, 1750, 1950, 6800, 6850; SuSE SLES [32−Bit] 106, 19, PCI−X QLogic QLA2340−E−SP4, 35, 52 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
IBM xSeries: x336 (8837)26, x346 (8840)26 AX100
35 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 106, 19, PCI−X QLogic QLA2340−E−SP35, 52 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, AX100
ML570(G2)45
36 Fujitsu Siemens Primergy: RX300, RX300 S2, TX200 S2, SuSE SLES [32−Bit] 106, 19, PCI−X QLogic QLE220−E−SP4, 16, 56, 58 FC−AL, EMC Y
TX300, TX300 S2; 20, 24, 25 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45,
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45
37 Dell PowerEdge 1955 SuSE SLES [32−Bit] 106, 19, PCI, PCI Dell LPe1105−M4, 10, 27, 28 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
38 Fujitsu Siemens Primergy TX200 S3; SuSE SLES [32−Bit] 106, 19, PCI, PCI Emulex LPe1150−E4, 10, 27, 28 FC−AL, EMC Y
HPQ Proliant: DL380(G5), DL580(G4) 20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
39 HPQ Proliant: DL380(G5), DL580(G4) SuSE SLES [32−Bit] 106, 19, PCI, PCI Emulex: LP101−E4, 9, 10, 27 , FC−AL, EMC Y
20, 24, 25 Express, LP1050−E10, 27, 29, LP982−E10, 27, FC−SW CLARiiON
PCI−X LPe111−E4, 10, 18, 27 ; AX100
HPQ: A8002A/FC2142SR
(LPe1150)4, 10, 27, 57 ,
AB429A/FC1143 (QLA2460)4, 44, 52,
AD167A/FC2143 (LP1150)4, 10, 27,
60, AE311A/FC1142SR (QLE2460)4,
32, 52, AE312A/FC1242SR
(QLE2462)4, 32, 52;
QLogic: QLA2340−E−SP35, 52,
QLE220−E−SP4, 16, 56, 58 ,
QLE2460−E−SP4, 32, 52,
QLE2462−E−SP4, 32, 52
40 Dell PowerEdge: 1800, 2800 SuSE SLES [32−Bit] 106, 19, PCI, PCI QLogic QLE220−E−SP4, 16, 58 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
41 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850; SuSE SLES [32−Bit] 106, 19, PCI, Emulex LP101−E4, 9, 10, 27 FC−AL, EMC Y
20, 24, 25 PCI−X FC−SW CLARiiON
HPQ Proliant: DL380(G3)45, DL380(G4)45, DL38545, AX100
DL580(G2)45, DL580(G3)45, DL58545, ML370(G3)45,
ML370(G4)45
42 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850 SuSE SLES [32−Bit] 106, 19, PCI, Emulex: LP1050−E4, 10, 27, 29 , FC−AL, EMC Y
20, 24, 25 PCI−X LP982−E4, 10, 27; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP4, 35, 52
43 HPQ Proliant: DL380(G3)45, DL380(G4)45, DL38545, SuSE SLES [32−Bit] 106, 19, PCI, Emulex: LP1050−E10, 27, 29, FC−AL, EMC Y
DL580(G2)45, DL580(G3)45, DL58545, ML370(G3)45, 20, 24, 25 PCI−X LP982−E10, 27; FC−SW CLARiiON
ML370(G4)45 AX100
HPQ AD167A/FC2143 (LP1150)4,
10, 27, 60
56 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, SuSE SLES [32−Bit] 8 SP3+ PCI−X QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
4600, 6600, 6650; v2.4.21−24119, 39 FC−SW CLARiiON
AX100
IBM xSeries: x235, x255, x360, x365, x440;
Samsung SS3840
57 HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045, SuSE SLES [32−Bit] 8 SP3+ PCI−X QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
DL760 (G2)45, DL76045, ML570(G2)45 v2.4.21−24119, 39 FC−SW CLARiiON
AX100
58 HPQ Proliant: DL14545, DL38545, DL58545 SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
v2.4.21−24119, 39 PCI−X QLogic QLA200−E−SP41, 43 FC−SW CLARiiON
AX100
59 Dell PowerEdge: 1800, 1850; SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
v2.4.21−24119, 39 PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL38545, DL580(G3)45, DL58545, AX100
ML370(G3)45;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
60 Dell PowerEdge 1850; SuSE SLES [32−Bit] 8 SP3+ PCI, QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
IBM xSeries: x345 (8670), x445 (8870) v2.4.21−24119, 39 PCI−X FC−SW CLARiiON
AX100
61 HPQ Proliant: DL380(G2)45, DL380(G3)45, DL38045, SuSE SLES [32−Bit] 8 SP3+ PCI, QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
DL580(G2)45, DL580(G3)45, ML370(G3)45 v2.4.21−24119, 39 PCI−X FC−SW CLARiiON
AX100
176 Dell PowerEdge: 2900, 2950, 6950 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP101−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050−E4, 10, 29, 62 , LP982−E4, 10, FC−SW CLARiiON
PCI−X 62 ; AX100
QLogic QLA2340−E−SP4, 33, 35
177 HPQ Proliant ML350(G4)45 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP101−E4, 9, 10, 79 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050−E10, 29, 79, LP982−E10, 79; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)4,
33, 44, AD167A/FC2143 (LP1150)4,
10, 60, 62 , AE369A/FC1243
(QLA2462)4, 33, 44;
QLogic: QLA200−E−SP4, 33, 41,
QLA210−E−SP4, 33, 41,
QLA2340−E−SP33, 35
178 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe111−E4, 10, 15, 18 , LPe1150−E4, FC−SW CLARiiON
IBM eServer 326m (Model 7969) PCI−X 10, 28, 30 ; AX100
QLogic: QLE2360−E−SP1, 4, 8, 33,
QLE2460−E−SP4, 32, 33
179 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E4, 10, 12, 62 , FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe1150−E4, 10, 15, 28 FC−SW CLARiiON
PCI−X AX100
180 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E4, 10, 62, FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe1150−E4, 10, 28, LPe1150−E4, FC−SW CLARiiON
PCI−X 10, 28, 79 AX100
181 Dell PowerEdge 1855; SuSE SLES [32−Bit] 9 SP2+: PCI−X Dell 2342M33, 35 FC−AL, EMC Y2, 31
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
182 Dell PowerEdge 1855 SuSE SLES [32−Bit] 9 SP2+: PCI−X Dell: LPe1105−M4, 10, 28, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 QME24624, 33, 59 FC−SW CLARiiON
AX100
183 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E4, 9, 10, 79 ; FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP4, 33, 41, FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, QLA210−E−SP4, 33, 41, AX100
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45 QLA2340−E−SP33, 35
184 Fujitsu Siemens Primergy: RX300, RX300 S2, TX200 S2, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E4, 10, 12, 15 ; FC−AL, EMC Y
TX300, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP4, 41, 70, FC−SW CLARiiON
QLA210−E−SP4, 33, 41 AX100
185 Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E10, 12, 15 FC−AL, EMC Y
S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
186 Fujitsu Siemens Primergy: RX200, RX200 S2, RX300, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050−E4, 10, 12, 15 FC−AL, EMC Y
RX300 S2, TX200, TX200 S2, TX300, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
187 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050−E10, 29, 79 FC−AL, EMC Y2, 31
DL56045, DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
188 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050Ex−E4, 10, 12, 62 FC−AL, EMC Y
S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
189 HPQ Proliant DL760 (G2)45 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP982−E10 FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
190 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP982−E10, 79 FC−AL, EMC Y2, 31
DL56045, DL76045, ML570(G2)45 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
191 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LPe1150−E4, 10, 15, 28 FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
192 Dell PowerEdge: 6800, 6850; SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex: LP101−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 LP1050−E4, 10, 29, 62 , LP982−E4, 10, FC−SW CLARiiON
Digital Henge SH4500R4; 62 AX100
IBM xSeries: x336 (8837)26, x346 (8840)26, x3850/x366
(8863)65, 66;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230
213 HPQ Proliant DL580(G3)45 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E4, 9, 10, 79 , FC−AL, EMC Y2, 31
v2.6.5−7.2016, 19, 20, PCI−X LP1050−E10, 29, 79, LP982−E10, 79; FC−SW CLARiiON
v2.6.5−7.202.7 AX100
HPQ AD167A/FC2143 (LP1150)4,
10, 60, 62 ;
QLogic: QLA200−E−SP4, 33, 41,
QLA210−E−SP4, 33, 41,
QLA2340−E−SP33, 35
214 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9 SP3: PCI Unisys: FCH732213−P64 FC−AL, EMC Y
ES7000/540 v2.6.5−7.244, v2.6.5−7.2446, (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
19, 20; FCH742313−P64 (LP9802)9, 10, 13, AX100
FCH752313−PCX (LP1050)9, 10, 13
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
215 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9 SP3: PCI QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, Express FC−SW CLARiiON
19, 20; AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
216 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP3: PCI Emulex LP1050Ex−E4, 10, 13 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, Express, FC−SW CLARiiON
19, 20; PCI−X AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
217 Fujitsu Siemens Primergy: RX200 S3, RX220, RX600 S3, SuSE SLES [32−Bit] 9 SP3: PCI QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
TX300 S3, TX600 S3 v2.6.5−7.244, v2.6.5−7.2446, Express, FC−SW CLARiiON
19, 20; PCI−X AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
218 Fujitsu Siemens Primergy TX200 S3 SuSE SLES [32−Bit] 9 SP3: PCI, PCI QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, Express, FC−SW CLARiiON
19, 20; PCI−X AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
219 Unisys ES7000/460 [32−Bit] SuSE SLES [32−Bit] 9 SP3: PCI, Unisys: FCH732213−P64 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, PCI−X (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
19, 20; FCH742313−P64 (LP9802)9, 10, 13, AX100
FCH752313−PCX (LP1050)9, 10, 13
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
220 Fujitsu Siemens Primergy BX620: S2F14, S214 SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050−E4, 10, 12, 13 FC−AL, EMC Y
v2.6.5−7.244, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
221 Fujitsu Siemens Primergy BX620: S2F14, S214, S3; SuSE SLES [32−Bit] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 35, FC−AL, EMC Y
v2.6.5−7.244, SP3+ 63 FC−SW CLARiiON
Fujitsu Siemens Primergy: BX62014, BX630 (8−way) v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
222 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9: SP3 PCI Unisys: FCH732213−P64 FC−AL, EMC Y36
ES7000/540 v2.6.5−7.244, SP3+ (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
v2.6.5−7.252, SP3+ FCH742313−P64 (LP9802)9, 10, 13, AX100
v2.6.5−7.257, SP3+ FCH752313−PCX (LP1050)9, 10, 13
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
223 IBM xSeries x3455 (7984) SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 9, 10, 13 ; FC−AL, EMC Y, Y36
v2.6.5−7.244, SP3+ Express IBM: 42C2069 (LPe11000)4, 10, 13, FC−SW CLARiiON
v2.6.5−7.252, SP3+ 57, 42C2071 (LPe11002)4, 10, 13, 57 ; AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+ QLogic: QLE2360−E−SP1, 4, 34,
v2.6.5−7.276, SP3+ QLE2460−E−SP4, 32, 34
v2.6.5−7.282
224 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y2, 31,
(407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express HBA for HP c−Class Bladesystem FC−SW CLARiiON Y23
v2.6.5−7.252, SP3+ (403621−B21)13, 21, 22 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
299 IBM BladeCenter HS20 (Model 8843) SuSE SLES [32−Bit] 9 SP1+ PCI−X IBM HS20 FC Exp Card (26K4841)4, FC−SW EMC Y2, 3
v2.6.5−7.1516, 7 5, 35 CLARiiON
AX100
300 IBM BladeCenter LS20 (Model 8850) SuSE SLES [32−Bit] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y2, 3
v2.6.5−7.1516, 7 Card4, 10, 11, 53 , HS20 FC Exp Card CLARiiON
(13N2203) for IBM eServer LS204, 5, AX100
35, HS20 FC SFF Exp Card
(26K4841) for IBM eServer LS204, 5,
35
301 IBM BladeCenter HS20 (Model: 8678)55, 8832)55, SuSE SLES [32−Bit] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y2, 3
8832−N1X), 8843); v2.6.5−7.1516, 7 Card4, 10, 53, 80 , HS20 FC Exp Card CLARiiON
(13N2203)4, 5, 35, HS20 FC Exp AX100
IBM BladeCenter HS40 (Model 8839) Card (48P7061)4, 5, 35
302 IBM BladeCenter HS20 (Model: 7981), 8678)55, 8832)55, SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y2, 31
8832−N1X), 8843); v2.6.5−7.201, v2.6.5−7.202.7 (13N2203)4, 33, 35, (48P7061)4, 33, CLARiiON
35 AX100
IBM BladeCenter HS40 (Model 8839)
303 IBM BladeCenter LS20 (Model 8850) SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 (26R0890)4, 33, 85, FC Exp Card CLARiiON
(13N2203) for IBM eServer LS204, AX100
33, 35, FC SFF Exp Card (26K4841)
for IBM eServer LS204, 33, 35
304 IBM BladeCenter HS20 (Model 8843) SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 (26R0890)4, 73, 85, FC Exp Card CLARiiON
(26K4841)4, 33, 35 AX100
305 IBM BladeCenter HS20 (Model: 7981), 8678)55, 8832)55, SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y2, 31
8832−N1X), 8843); v2.6.5−7.201, v2.6.5−7.202.7 Card4, 10, 53, 62 , HS20 4GB CLARiiON
Standard FC Exp Card (26R0884)4, AX100
IBM BladeCenter: HS40 (Model 8839), LS20 (Model 8850) 33, 69
306 Fujitsu Siemens Primergy: RX300 S2, TX300 S2 SuSE SLES [32−Bit] 9 SP2+: PCI−X QLogic QLA2340−E−SP35 FC−SW EMC Y
v2.6.5−7.201, v2.6.5−7.202.7; CLARiiON
AX100
SuSE SLES [32−Bit] 9: SP3
v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
307 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLA2340−E−SP35 FC−SW EMC Y
v2.6.5−7.244, SP3+ Express CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
308 Fujitsu Siemens Primergy: RX200 S3, RX220, RX600 S3, SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLA2340−E−SP35 FC−SW EMC Y
TX300 S3, TX600 S3 v2.6.5−7.244, SP3+ Express, CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
309 Bull NovaScale 2320; SuSE SLES [32−Bit] 9: SP3 PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
Digital Henge PowerBlade BS200L v2.6.5−7.244, SP3+ Dual port: for NovaScale Blade CLARiiON
v2.6.5−7.252, SP3+ Series CFSN202−110034, 54, mini AX100
v2.6.5−7.257, SP3+ for NovaScale Blade 2021
v2.6.5−7.267, SP3+ CFSN202−210034, 54
v2.6.5−7.276, SP3+
v2.6.5−7.282
310 Bull NovaScale 2320 SuSE SLES [32−Bit] 9: SP3 PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.6.5−7.244, SP3+ Dual port: for NovaScale Blade CLARiiON
v2.6.5−7.252, SP3+ Series CFSN202−110084, mini for AX100
v2.6.5−7.257, SP3+ NovaScale Blade 2021
v2.6.5−7.267, SP3+ CFSN202−210054;
v2.6.5−7.276, SP3+
v2.6.5−7.282 Bull SBEFCM (SFF) Mezzanine:
HBA34, 54, HBA84;
Bull SBEFCM4 (SFF) 4Gb
Mezzanine HBA34, 51
311 Digital Henge PowerBlade BS200L SuSE SLES [32−Bit] 9: SP3 PCI−X Bull SBEFCM (SFF) Mezzanine FC−SW EMC Y
v2.6.5−7.244, SP3+ HBA4, 34, 54; CLARiiON
v2.6.5−7.252, SP3+ Digital Henge Digital Henge: AX100
v2.6.5−7.257, SP3+ SBEFCM44, 34, 51, SBEFCM34, 54,
v2.6.5−7.267, SP3+ SBFCM34, 54;
v2.6.5−7.276, SP3+
v2.6.5−7.282 Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD4, 34, 54
312 Fujitsu Siemens Primergy TX200 S3 SuSE SLES [32−Bit] 9: SP3 PCI, PCI QLogic QLA2340−E−SP35 FC−SW EMC Y
v2.6.5−7.244, SP3+ Express, CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
47. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
17 HPQ Proliant ML350(G4)13 SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, Express, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)4, 14, 15,
AD167A/FC2143 (LP1150)3, 4, 5, 36,
AE369A/FC1243 (QLA2462)4, 14, 15;
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14
18 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP1050Ex−E3, 4, 5, 33, LPe1150−E3, 4, 19, 35 FC−AL, EMC Y
RX220 v2.6.5−7.201, v2.6.5−7.2017, 8, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
19 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP1050Ex−E3, 4, 5, LPe1150−E3, 4, 19, FC−AL, EMC Y1, 2
RX220 v2.6.5−7.201, v2.6.5−7.2017, 8, Express, LPe1150−E3, 4, 19, 23 FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
20 Dell PowerEdge 1855; SuSE SLES [EM64T] 9 SP2+: PCI−X Dell 2342M9, 14 FC−AL, EMC Y1, 2
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
v2.6.5−7.202.7 AX100
21 Dell PowerEdge 1855 SuSE SLES [EM64T] 9 SP2+: PCI−X Dell: LPe1105−M3, 4, 5, 19, QME24624, 14, 40 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
v2.6.5−7.202.7 AX100
22 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LP1050Ex−E3, 4, 5, 33 FC−AL, EMC Y
RX200 S2, RX600 S2, TX600 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
S2 v2.6.5−7.202.7 AX100
23 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LPe1150−E3, 4, 19, 35 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
v2.6.5−7.202.7 AX100
24 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 4, 5, 6, LP1050−E3, 4, 5, 22, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, LP982−E3, 4, 5; FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.202.7 AX100
37
IBM xSeries: x336 (8837) , QLogic QLA2340−E−SP4, 9, 14
x346 (8840)37, x3850/x366
(8863)38, 39;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
25 HPQ Proliant DL360(G4)13 SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 AX100
HPQ: AB429A/FC1143 (QLA2460)4, 14, 15,
AD167A/FC2143 (LP1150)3, 4, 5, 36,
AE369A/FC1243 (QLA2462)4, 14, 15;
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14
35 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
ML370(G4)13 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14
36 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X QLogic QLA2340−E−SP9 FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 v2.6.5−7.201, v2.6.5−7.202.7; FC−SW CLARiiON
S2 AX100
SuSE SLES [EM64T] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
37 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex LP1050−E3, 4, 33, 35 ; FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.5−7.2017, 8, v2.6.5−7.202.7 Fujitsu Siemens BX600−FC22Q4, 9, 45, 50 FC−SW CLARiiON
AX100
38 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LP1050−E3, 4, 33, 35 FC−AL, EMC Y
RX200 S2 v2.6.5−7.2017, 8, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
39 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
DL580(G3)13, ML370(G4)13 v2.6.5−7.2017, 8, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14
40 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050−E3, 4, 11, 33 FC−AL, EMC Y
BX620: S2F60, S260; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
BX630: (2−way), (4−way)
41 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 9, 45 FC−AL, EMC Y
BX620: S2F60, S260, S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
BX630 (8−way)
42 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 9, 10, 45 FC−AL, EMC Y
BX620 S3, BX630 (2−way), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
BX630 (4−way), BX630 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
(8−way) v2.6.5−7.276, SP3+ v2.6.5−7.282
43 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 33, 34 ; FC−AL, EMC Y
RX300 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express QLogic: QLA2340−E−SP4, 9, QLA2340−E−SP4, 9, 10, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ QLA2340−E−SP9, QLA2340−E−SP9, 10 AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
44 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 6, 11; FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express QLogic QLE2360−E−SP4, 10, 30, 31 FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)37;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
57 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP1050Ex−E3, 4, 6, 11, LP1150−E3, 4, 11, 32 , FC−AL, EMC Y17
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, LPe111−E3, 4, 11, 24 ; FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 IBM: 24P0960 (QLA2340)4, 9, 10, 29 , 24P8053
(QLA2342)4, 9, 10, 39M5894 (QLA2460)4, 10, 16,
39M5895 (QLA2462)4, 10, 16;
QLogic: QLA2460−E−SP4, 10, 16, QLE2360−E−SP4,
10, 30, QLE2460−E−SP4, 10, 16
58 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI IBM: 24P0960 (QLA2340)4, 9, 28, 29 , 24P8053 FC−AL, EMC Y
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, (QLA2342)4, 9, 28, 39M5894 (QLA2460)4, 10, 16, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X 39M5895 (QLA2462)4, 10, 16; AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
QLogic: QLA2460−E−SP4, 10, 16, QLE2360−E−SP4,
10, 30
59 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP4, 9, 10 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Fujitsu Siemens Primergy:
RX200 S3, RX220, RX600
S3, TX300 S3, TX600 S3;
IBM xSeries: x3550 (7978),
x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
60 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX300 S3, TX600 S3; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
HPQ Proliant ML350(G4)13
61 Dell PowerEdge: 1850, 1900, SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE220−E−SP4, 25, 26 FC−AL, EMC Y
2850, 2900, 2950, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
62 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic: QLA2340−E−SP4, 9, QLA2340−E−SP9 FC−AL, EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX300 S3, TX600 S3 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
63 Dell PowerEdge 1855; SuSE SLES [EM64T] 9: SP3 PCI−X Dell 2342M9, 10 FC−AL, EMC Y
Unisys ES3105 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
64 Dell PowerEdge 1855 SuSE SLES [EM64T] 9: SP3 PCI−X Dell: LPe1105−M3, 4, 11, 19 , QME24624, 10, 40 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
65 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP1050−E3, 4, 11, 33 FC−AL, EMC Y
RX200 S2, RX300 S2, TX200 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
S2, TX300 S2 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
66 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP1050Ex−E3, 4, 33, 34 FC−AL, EMC Y
RX200 S2, RX600 S2, TX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
S2 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
67 IBM xSeries x3850/x366 SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP9802−E3, 4, 6, 11 FC−AL, EMC Y
(8863)38, 39 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
68 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
69 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 4, 33, LP101−E3, 33; FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
S2 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ Fujitsu Siemens S26361−F2843−E1 (Emulex: AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 LP9802)3, 33, 34, LP9802)3, 33, 34, 51, 52
78 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y
TX200 S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
DL580(G4) v2.6.5−7.276, SP3+ v2.6.5−7.282
79 HPQ Proliant DL380(G5) SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LP101−E3, 4, 6, LP1050−E3, 22, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 10, 15, AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)4, 10, 15;
QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLE220−E−SP4, 25, 26, 27
86 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI, QLogic QLA2340−E−SP4, 9, 10 FC−AL, EMC Y
2600, 2650, 2800, 2850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
RX800 S2;
Samsung: ES470, ES570,
SS140
87 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
RX800 S2; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
HPQ Proliant: DL380(G4)13, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
ML370(G4)13 v2.6.5−7.276, SP3+ v2.6.5−7.282
88 HPQ Proliant DL580(G4) SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 11, 22, FC−AL, EMC Y
v2.6.5−7.2447, 8, SP3+ v2.6.5−7.252, Express, LP982−E3; FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, PCI−X AX100
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLA2340−E−SP9, 10, QLE220−E−SP4, 25, 26, 27
89 HPQ Proliant DL580(G3)13 SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 11, 22, FC−AL, EMC Y
v2.6.5−7.2447, 8, SP3+ v2.6.5−7.252, PCI−X LP982−E3; FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, AX100
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLA2340−E−SP9, 10, QLE220−E−SP4, 25, 26, 27
90 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP1+ PCI−X IBM HS20 FC Exp Card (26K4841)4, 9, 44 FC−SW EMC Y2, 43
(Model 8843) v2.6.5−7.1517, 8, 42 CLARiiON
AX100
91 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 12, 48 , FC−SW EMC Y2, 43
(Model: 8832−N1X), 8843) v2.6.5−7.1517, 8, 42 HS20 FC Exp Card (13N2203)4, 9, 44, HS20 FC Exp CLARiiON
Card (48P7061)4, 9, 44 AX100
92 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP1+ PCI−X QLogic QLA2340−E−SP9 FC−SW EMC N2, 43
RX200 S2, RX300 S2, RX600 v2.6.5−7.1517, 8, 42 CLARiiON
S2, TX300 S2, TX600 S2 AX100
93 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card (26R0890)4, 49, FC−SW EMC Y1, 2
(Model 8843) v2.6.5−7.201, v2.6.5−7.2017, 8, 50, FC Exp Card (26K4841)4, 9, 14 CLARiiON
v2.6.5−7.202.7 AX100
94 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 5, 12, FC−SW EMC Y1, 2
(Model: 8832−N1X), 8843) v2.6.5−7.201, v2.6.5−7.2017, 8, HS20 4GB Standard FC Exp Card (26R0884)4, 14, CLARiiON
v2.6.5−7.202.7 53, HS20 FC Exp Card (13N2203)4, 9, 14, HS20 FC AX100
Exp Card (48P7061)4, 9, 14
95 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X QLogic QLA2340−E−SP9 FC−SW EMC Y
RX300 S2, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7; CLARiiON
AX100
SuSE SLES [EM64T] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
96 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP9 FC−SW EMC Y
RX300 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
97 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP9 FC−SW EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, CLARiiON
S3, TX300 S3, TX600 S3 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
98 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM HS20 FC Exp Card (26K4841)4, 9, 10 FC−SW EMC Y
(Model 8843) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
99 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM HS20 FC Exp Card: (13N2203)4, 9, 10, FC−SW EMC Y
(Model: 8832−N1X), 8843); v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ (48P7061)4, 9, 10 CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
IBM BladeCenter HS21 v2.6.5−7.276, SP3+ v2.6.5−7.282
(Model 8853)59
28 HPQ Proliant BL460c: SuSE SLES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(416653−B21), (416654−B21), [x86_64] 105, (403619−B21)17, 21 FC−SW CLARiiON
(416655−B21), (416656−B21), 6, 7, 8 AX100
(432636−B21);
HPQ Proliant BL480c:
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
29 Fujitsu Siemens Primergy: RX200 SuSE SLES PCI−X QLogic QLA2340−E−SP16, 17 FC−AL, EMC Y
S2, RX300 S2, RX600 S2, TX200 [x86_64] 105, FC−SW CLARiiON
S2, TX300 S2, TX600 S2; 6, 7, 8 AX100
HPQ Proliant DL360(G4)24
30 Dell PowerEdge: 1950, 6800, 6850; SuSE SLES PCI−X QLogic QLA2340−E−SP4, 16, 17 FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX600 6, 7, 8 AX100
S2, TX600 S2;
IBM xSeries: x336 (8837)15, x346
(8840)15
31 Fujitsu Siemens Primergy: RX300 SuSE SLES PCI−X QLogic QLE220−E−SP4, 18, 19, 23 FC−AL, EMC Y
S2, TX200 S2, TX300 S2; [x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100
HPQ Proliant DL360(G4)24
32 IBM xSeries: x3800/x260 (8865)43, SuSE SLES PCI−X42 Emulex: LP101−E1, 2, 3, 4, LP1050−E2, 3, 4, 33, LP982−E2, 3, 4 FC−AL, EMC Y
44,x3950/x3950E/x460 (8872, [x86_64] 105, FC−SW CLARiiON
8874)43, 44 6, 7, 8 AX100
33 Dell PowerEdge 1955 SuSE SLES PCI, PCI Dell: LPe1105−M2, 3, 4, 30, QME24624, 17, 36 FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
34 Fujitsu Siemens Primergy TX200 SuSE SLES PCI, PCI Emulex LPe1150−E2, 3, 4, 30; FC−AL, EMC Y
S3; [x86_64] 105, Express, QLogic QLA2340−E−SP16, 17 FC−SW CLARiiON
HPQ Proliant: DL380(G5), 6, 7, 8 PCI−X AX100
DL580(G4)
35 HPQ Proliant: DL380(G5), SuSE SLES PCI, PCI Emulex: LP101−E1, 2, 3, 4, LP1050−E2, 3, 33, LP982−E2, 3, LPe111−E2, 3, FC−AL, EMC Y
DL580(G4) [x86_64] 105, Express, 4, 29; FC−SW CLARiiON
6, 7, 8 PCI−X AX100
HPQ: A8002A/FC2142SR (LPe1150)2, 3, 4, 35, AB429A/FC1143
(QLA2460)4, 17, 28, AD167A/FC2143 (LP1150)2, 3, 4, 31,
AE311A/FC1142SR (QLE2460)4, 17, 22, AE312A/FC1242SR (QLE2462)4,
17, 22;
Sun Solaris
Sun Solaris
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex: LP10000−E2, 6, 10, 11, 14, 16, 37, 38, 39, 40, 41, 42, 43 , LP9002−E FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris (LP9002L−E)2, 6, 10, 11, 14, 16, 37, 39, 41, 42, 44, 45 , LP9802−E2, 6, 10, 11, FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 103, 4, 5 14, 16, 37, 38, 39, 40, 41, 42, 43 ; AX100
QLogic QLA2340−E−SP2, 6, 8, 16, 31, 32, 33, 34, 35, 36 ;
Sun SG−XPCI1FC−EM2 (LP10000)2, 10, 11, 14, 37
2 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Sun: SG−XPCI1FC−QL2 (QLA2340)2, 6, 8, 16, 21, 22, 23, 24, 25, 26, 27, FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 28, 29, 30 , X6767A (SG−XPCI1FC−QF2)2, 6, 7, 8 FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 103, 4, 5 AX1001
3 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex LP8000−EMC6, 41, 42, 46, 47, 48, 49 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 104, 5 AX100
4 Sun Sun Fire: 4800, 6800 Sun PCI Emulex LP9002C−E2, 6, 10, 37, 40, 41, 42, 44, 46, 47 FC−AL, EMC N
Solaris FC−SW CLARiiON
104, 5 AX100
5 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP8, 9, 12, 13, 16, 18, 31, 33, 34, 35, 36, 50 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 8 FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 AX1001
6 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−QL2 (QLA2340)6, 8, 9, 12, 13, 21 , X6767A FC−AL, EMC N
Solaris 8 (SG−XPCI1FC−QF2)2, 6, 7, 8, 9, 12, 13 FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, AX1001
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R20, 250, 420R20, 450
7 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun SG−XPCI1FC−EM2 (LP10000)2, 9, 10, 11, 12, 13, 14, 16, 18 FC−AL, EMC N
Solaris FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, 819 AX1001
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R20, 250, 420R20, 450
8 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP8, 9, 12, 13, 16, 18, 31, 33, 34, 35, 36, 50 ; FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 9 Sun: SG−XPCI1FC−EM2 (LP10000)2, 9, 10, 11, 12, 13, 14, 16, 17, 18 , FC−SW CLARiiON
V250, V480, V490, V880, V890 SG−XPCI1FC−QL2 (QLA2340)6, 8, 9, 12, 13, 21 , X6767A AX1001
(SG−XPCI1FC−QF2)2, 6, 7, 8, 9, 12, 13, 17
9 Sun Sun Fire V440 Sun PCI QLogic QLA2340−E−SP8, 9, 12, 13, 16, 18, 31, 33, 34, 35, 36, 50 FC−AL, EMC N
Solaris FC−SW CLARiiON
915 AX1001
10 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−EM2 (LP10000)2, 9, 10, 11, 12, 13, 14, 16, 17, 18 , FC−AL, EMC N
Solaris SG−XPCI1FC−QL2 (QLA2340)6, 8, 9, 12, 13, 21 , X6767A FC−SW CLARiiON
Sun Sun Fire: V210, V440; 915 (SG−XPCI1FC−QF2)2, 6, 7, 8, 9, 12, 13, 17 AX1001
54 Dell PowerEdge: 1850, 1950, 2800, VMware ESX Server: v3.0.11, 2, PCI QLogic QLE2460−E−SP22, 26, 27 FC−AL, EMC Y
2850, 6800, 6850 4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, Express FC−SW CLARiiON
4, 20, 21 AX100
55 HPQ Proliant DL360(G4)40 VMware ESX Server: v3.0.11, 2, PCI−X HPQ AB429A/FC1143 (QLA2460)22, 26, 53 FC−AL, EMC Y7, 25
4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, FC−SW CLARiiON
4, 20, 21 AX100
56 HPQ Proliant DL380(G5) VMware ESX Server: v3.0.11, 2, PCI, PCI HPQ AB429A/FC1143 (QLA2460)22, 26, 53 FC−AL, EMC Y7, 25
4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, Express, FC−SW CLARiiON
4, 20, 21 PCI−X AX100
57 HPQ Proliant: DL380(G4)40, DL38540, VMware ESX Server: v3.0.11, 2, PCI, HPQ AB429A/FC1143 (QLA2460)22, 26, 53 FC−AL, EMC Y7, 25
DL58540, ML370(G4)40 4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, PCI−X FC−SW CLARiiON
4, 20, 21 AX100
58 Dell PowerEdge: 2900, 2950; VMware ESX Server: v3.01, 2, 4, PCI Emulex LPe1150−E8, 22, 23, 24 FC−AL, EMC Y7, 25
16, 20, 21 , v3.01, 2, 4, 20, 21 Express, FC−SW CLARiiON
Fujitsu Siemens Primergy RX600 S3 PCI−X AX100
59 Dell PowerEdge 1955 VMware ESX Server: v3.01, 2, 4, PCI, PCI Dell 2342M12, 13 FC−AL, EMC Y7, 25
16, 20, 21 , v3.01, 2, 4, 20, 21 , v3.02, Express, FC−SW CLARiiON
4, 16, 20, 21 , v3.02, 4, 20, 21 PCI−X AX100
60 HPQ Proliant DL380(G3)40 VMware ESX Server: v3.02, 4, 16, PCI Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31; FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
QLogic QLA2340−E−SP12, 33 AX100
61 Fujitsu Siemens Primergy BX66038 VMware ESX Server: v3.02, 4, 16, PCI Fujitsu Siemens BX600−FC22Q12, 13, 22, 37 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
62 Fujitsu Siemens Primergy RX300 S3 VMware ESX Server: v3.02, 4, 16, PCI Emulex LP1050Ex−E8, 22, 28, 31 ; FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express QLogic QLA2340−E−SP12 FC−SW CLARiiON
AX100
107 Dell PowerEdge 185554 VMware ESX Server v2.5.11, 2, PCI−X Dell 2342M12, 13 FC−SW EMC Y7, 25
3, 4, 5 CLARiiON
AX10011
108 HPQ Proliant BL45p VMware ESX Server v2.5.11, 2, PCI−X HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
AX10011
109 IBM BladeCenter HS20 (Model: VMware ESX Server v2.5.11, 2, PCI−X IBM HS20 FC Exp Card (13N2203)12, 13 FC−SW EMC Y7, 25
8678)39, 8832)39, 8832−N1X); 3, 4, 5 CLARiiON
AX10011
IBM BladeCenter HS40 (Model 8839)
110 IBM BladeCenter HS20 (Model 8843) VMware ESX Server v2.5.11, 2, PCI−X IBM HS20 FC Exp Card (26K4841)12, 13, 22, 45 FC−SW EMC Y7, 25
3, 4, 5 CLARiiON
AX10011
111 IBM BladeCenter HS20 (Model: VMware ESX Server v2.5.11, 2, PCI−X IBM HS20 FC Exp Card (48P7061)12, 13, 22 FC−SW EMC Y7, 25
8678)39, 8832)39, 8832−N1X), 8843) 3, 4, 5 CLARiiON
AX10011
112 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server v2.5.11, 2, PCI−X QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
2650, 4600, 6600, 6650; 3, 4, 5 CLARiiON
AX10011
Fujitsu Siemens Primergy: RX300 S2,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL56040, DL74040,
DL760 (G2)40, DL76040, ML570(G2)40,
ML570(G3)40, 54;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)43, xSeries x440;
NEC Express 5800 120Lh;
Sun: V20z, V40z
113 HPQ Proliant BL20p (G2) VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL20p (G2) 300874−B2112, 19 CLARiiON
AX10011
114 HPQ Proliant BL20p (G3) VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL20p (G3) 361426−B2112, 19 CLARiiON
AX10011
115 HPQ Proliant BL25p VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
AX10011
116 HPQ Proliant BL35p VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL30p/BL35p 354054−B2112, 19 CLARiiON
AX10011
117 HPQ Proliant BL30p VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL30p/BL35p 354054−B2119, 49 CLARiiON
AX10011
118 IBM xSeries x3950/x3950E/x460 (8872, VMware ESX Server v2.5.11, 2, PCI−X42 QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
8874)43, 54 3, 4, 5 CLARiiON
AX10011
119 HPQ Proliant: DL380(G2)40, VMware ESX Server v2.5.11, 2, PCI, QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
DL380(G4)40, 54, DL38040, DL38540, 3, 4, 5 PCI−X CLARiiON
DL580(G2)40, DL580(G3)40, 54, AX10011
DL58540, ML370(G3)40, ML370(G4)40,
54;
123 Fujitsu Siemens Primergy: RX600, VMware ESX Server v2.5.21, 2, PCI, QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
RX800, RX800 S2, TX600; 3, 4, 5 PCI−X CLARiiON
AX10011
HPQ Proliant: DL380(G2)40,
DL380(G4)40, DL38040, DL38540,
DL580(G2)40, DL580(G3)40, DL58540,
ML370(G3)40, ML370(G4)40;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
124 Dell PowerEdge 6850 VMware ESX Server v2.5.31, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5 Express CLARiiON
AX100
125 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server v2.5.31, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5 Express, CLARiiON
IBM xSeries x336 (8837)50 PCI−X AX100
126 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server v2.5.31, 2, PCI Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
3, 4, 5 Express, CLARiiON
IBM xSeries x336 (8837)50; PCI−X AX100
NEC Express 5800 110Rg−1
127 HPQ Proliant BL20p (G3) VMware ESX Server v2.5.31, 2, PCI−X18 HPQ Emulex−based BL20p (G3) Fibre Channel FC−SW EMC Y
3, 4, 5 Mezzanine HBA − 394757−B2110, 17 CLARiiON
AX10011
128 Dell PowerEdge: 1950, 6850 VMware ESX Server v2.5.41, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express CLARiiON
AX100
129 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, PCI Emulex: LP1050−E8, 10, 22, 31 , LP1050−E8, 10, 32, FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express LP982−E8, 10 CLARiiON
AX100
130 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
3, 4, 5, 14, 15, 16 Express CLARiiON
AX10011
131 Dell PowerEdge: 1950, 6850 VMware ESX Server v2.5.41, 2, PCI QLogic QLE2360−E−SP12, 22, 46 FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express CLARiiON
AX10011
132 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, PCI QLogic: QLA2340−E−SP12, 13, QLE2360−E−SP12, FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express 22, 29, 46 CLARiiON
AX10011
133 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, PCI Emulex LP1050−E8, 10, 22, 31 FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
134 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
2950, 6850; 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
IBM xSeries x336 (8837)50
135 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
2950, 6850; 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
IBM xSeries x336 (8837)50;
NEC Express 5800 110Rg−1
136 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
2950, 6850; 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
IBM xSeries: x336 (8837)50, x346
(8840)50
137 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
138 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI QLogic QLE2360−E−SP12, 22, 29, 46 FC−SW EMC Y
2950 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
139 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, PCI QLogic QLE2360−E−SP12, 22, 46 FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
140 HPQ Proliant BL20p: (G3), (G4) VMware ESX Server v2.5.41, 2, PCI−X18 HPQ: Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, 14, 15, 16 Proliant BL20p (G3) 361426−B2112, 19, CLARiiON
Emulex−based BL20p (G3) Fibre Channel AX10011
Mezzanine HBA − 394757−B2110, 17
141 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v2.5.41, 2, PCI, PCI Emulex: LP1050−E8, 10, 32, LP1050Ex−E8, 9, 10, 22 , FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express, LP982−E8, 10 CLARiiON
PCI−X AX100
142 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v2.5.41, 2, PCI, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
143 HPQ Proliant BL460c: (416653−B21), VMware ESX Server v3.0.11, 2, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−SW EMC N
(416654−B21), (416655−B21), 4, 16, 20 c−Class Bladesystem (403619−B21)57, 60 CLARiiON
(416656−B21), (432636−B21); AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
152 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server: v2.5.21, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Express, CLARiiON
IBM xSeries: x336 (8837)50, x346 PCI−X AX10011
(8840)50
153 Dell PowerEdge: 1850, 2850 VMware ESX Server: v2.5.21, 2, PCI QLogic QLE2360−E−SP12, 22, 29, 46 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Express, CLARiiON
PCI−X AX10011
154 HPQ Proliant BL20p (G3) VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Proliant BL20p (G3) 361426−B2112, 19 CLARiiON
AX10011
155 Fujitsu Siemens Primergy BX620: VMware ESX Server: v2.5.21, 2, PCI Fujitsu Siemens BX600−FC22Q12, 13, 22, 37 FC−SW EMC Y
S2F38, S238; 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
Fujitsu Siemens Primergy: BX62038,
BX630 (2−way)65, BX66038
156 Dell PowerEdge: 1550, 255044, 6450; VMware ESX Server: v2.5.21, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
HPQ Proliant: DL360(G2)40, DL36040, 2, 3, 4, 5, 14, 15, 16 AX10011
DL380(G3)40, DL58040;
IBM xSeries: x330, x335;
NEC Express 5800 140Hd
157 Dell PowerEdge 6850 VMware ESX Server: v2.5.21, 2, PCI Dell 2362M12, 47, 48 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Express, CLARiiON
2, 3, 4, 5, 14, 15, 16 PCI−X AX10011
158 Dell PowerEdge 1855 VMware ESX Server: v2.5.21, 2, PCI−X Dell 2342M12, 13 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
159 HPQ Proliant BL45p VMware ESX Server: v2.5.21, 2, PCI−X HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
160 IBM BladeCenter HS20 (Model: VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC Exp Card (13N2203)12, 13 FC−SW EMC Y
8678)39, 8832)39, 8832−N1X); 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
IBM BladeCenter HS40 (Model 8839)
161 IBM BladeCenter HS20 (Model 8843) VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC Exp Card (26K4841)12, 13, 22, 45 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
162 IBM BladeCenter HS20 (Model: VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC Exp Card (48P7061)12, 13, 22 FC−SW EMC Y
8678)39, 8832)39, 8832−N1X), 8843) 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
163 IBM BladeCenter LS20 (Model 8850) VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM eServer FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, LS2012, 13, 22, SFF Exp Card (26K4841) for IBM CLARiiON
2, 3, 4, 5, 14, 15, 16 eServer LS2012, 13, 22 AX10011
164 HPQ Proliant BL20p (G2) VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL20p (G2) 300874−B2112, 19 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
165 HPQ Proliant BL25p VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
166 HPQ Proliant BL35p VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL30p/BL35p 354054−B2112, 19 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
51. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
52. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
53. BIOS 1.17
54. Single core processors only.
55. This driver is included in the VMware ESX kernel.
56. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
57. Driver Version 7.07.04 This driver is included in the VMware ESX kernel.
58. BIOS 1.47
59. BIOS 1.12
60. BIOS 1.16
61. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
62. VxVM is not supported on servers booting from the array.
63. BIOS 6.00a1
64. Firmware Version 2.50a8
65. Only supported in a boot from SAN configuration.
Cluster Software
Microsoft Windows 2000
EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.
Novell Netware
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.
Novell Netware
Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Novell Netware: 6.5, 6.5 SP1.1, QLogic QLA2340−E−SP QLogic SANBox 15 15 256 128 Y EMC
6.5 SP2, 6.5 SP3 SB1404−10AJ−E CLARiiON
AX100
2 Novell Netware: 6.5, 6.5 SP1.1, QLogic: QLA200−E−SP, QLogic SANBox 15 15 256 128 Y EMC
6.5 SP2, 6.5 SP3 QLA2340−E−SP SB3050−08A−E CLARiiON
AX100
3 Novell Netware: 6.5, 6.5 SP1.1, QLogic: QLA200−E−SP, EMC Connectrix: 15 15 256 128 Y EMC
6.5 SP2, 6.5 SP3 QLA2340−E−SP, QLE2360−E−SP 3250−VL2E1, DS−8B2−0DL; CLARiiON
AX100
McDATA ES−43002
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.
Sun Solaris
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.
Sun Solaris
Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Sun Solaris: QLogic QLA2340−E−SP; Brocade Silkworm: 205E, 207E; 4 15 256 128 Y EMC
10, 8, 9 Sun: SG−XPCI1FC−QL2 (QLA2340), CLARiiON
X6767A (SG−XPCI1FC−QF2) EMC Connectrix: 3250−VL2E2, DS−220B−FF−D3, AX100
DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43001, ES−4400, ES−4700
2 Sun Solaris: Sun SG−XPCI1FC−EM2 (LP10000) Brocade Silkworm: 205E, 207E; 4 15 256 128 Y EMC
8, 9 CLARiiON
EMC Connectrix: 3250−VL2E2, DS−220B−FF−D3, AX100
DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43001, ES−4400, ES−4700
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. This switch is offered by Dell as the Brocade VL2 LC.
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.
For tape devices connected directly to a backup host, EMC strongly recommends that the component vendors' supported configuration matrices are reviewed
(host configuration matrix for compatibility with SCSI or Fibre Channel interface used to connect to tape device, tape device vendor for compatibility with
selected SCSI or Fibre Channel interface and backup software vendor for compatibility with the tape device).
Path Definition
A path is a connection between an HBA port and a target SP port in a storage system. Each HBA that is directly connect to, or zoned through, a switch to an SP
port is considered an initiator of that SP port. An HBA port can be zoned through different switch ports to the same SP port or to different SP ports, resulting in
multiple paths between the HBA port and an SP.
Remote Replication
For customers planning to utilize the AX150 along with CLARiiON arrays running EMC SAN Copy software, adding SAN Copy/E software to the AX150
provides the ability to replicate data from the AX150 via Navisphere. For example, using the AX150, SAN Copy/E can be used to replciate data from branch
offices back to the data center to provide disaster recovery protection and to consolidate the backup process. The SAN Copy/E application on an AX150 is
qualified for connectivity to the CX arrays running SAN Copy (for the SAN Copy application only, not host attach) through professionally installed switches listed
on the AX Support Matrix. For cost effective remote replication solutions, as well as low cost DR implementations, the QLogic iSR6142 SAN Router has been
qualified.
2 Fujitsu Siemens Fujitsu PCI Fujitsu Siemens: LP10000−E (GP70F−CF33)3, 4, 5, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 , FC−AL, EMC N
PRIMEPOWER: 200, 250, Siemens LP11000−E (GP70F−CF36)3, 4, 5, 6, 13, 14, 15, 16 , LP9802−E (GP70F−CF31)3, 4, 5, 7, 8, 9, FC−SW CLARiiON
400, 450, 600, 650, 850 Solaris: 8, 9 10, 11, 12, 13, 14, 15, 16 AX150
1. FSC requires all patches for Solaris 10 be obtained through FSC in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers running
Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
2. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
3. FCode Value 1.50a4
4. SNIA HBA API Supported.
5. FCode Value 1.41a4
6. Firmware Version 2.10a9
7. Firmware Version 1.91a1
8. Firmware Version 1.90a4
9. Driver Version 6.02e
10. Driver Version 6.02f
11. Driver Version 6.02hx2
12. Driver Version 6.01f
13. Driver Version SAN 4.4.10
14. Driver Version SAN 4.4.7a
15. Driver Version SAN 4.4.9
16. Driver Version SAN 4.4.8
17. The SAN driver is part of the OS.
18. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
19. Firmware Version 3.92a3
20. Driver Version 5.01e
Fujitsu Solaris
Fujitsu Solaris
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot Comments
1 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex: LP10000−E4, 5, 6, 7, 8, 9, 10, 14, 15, 16 , FC−AL, EMC Y See12
2500, 450, 650, 850, 900 1017, 18 LP9802−E4, 5, 6, 7, 8, 9, 10, 14, 15, 16 FC−SW CLARiiON
AX150
2 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC219, PW008FC319 FC−AL, EMC N See12
2500, 450, 650, 850, 900 1017, 18 FC−SW CLARiiON
AX150
3 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 8 PCI Emulex LP9802−E1, 2, 3, 4, 5, 6, 7, 8, 9, 10 FC−AL, EMC Y See12
2500, 450, 650, 850, 900 02/0213 FC−SW CLARiiON
AX150
4 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 8 PCI Fujitsu: PW008FC220, 21, 22, 23 , PW008FC320, 21, 22, 23 FC−AL, EMC N See12
2500, 450, 650, 850, 900 02/0213 FC−SW CLARiiON
AX150
5 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 9 PCI Emulex LP9802−E1, 2, 3, 4, 5, 6, 7, 8, 9, 10 FC−AL, EMC Y See12
2500, 450, 900 04/0311 FC−SW CLARiiON
AX150
6 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 9 PCI Fujitsu: PW008FC220, 21, 22, 23 , PW008FC320, 21, 22, 23 FC−AL, EMC N See12
2500, 450, 900 04/0311 FC−SW CLARiiON
AX150
7 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris 9 PCI Emulex LP9802−E1, 2, 3, 4, 5, 6, 7, 8, 9, 10 FC−AL, EMC Y See12
12/0211 FC−SW CLARiiON
AX150
8 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris 9 PCI Fujitsu: PW008FC220, 21, 22, 23 , PW008FC320, 21, 22, 23 FC−AL, EMC N See12
12/0211 FC−SW CLARiiON
AX150
1. Driver Version SAN 4.4.7a
2. Driver Version SAN 4.4.8
3. Driver Version 6.01f
4. Driver Version 6.02f
5. FCode Value 1.41a4
6. SNIA HBA API Supported.
7. Firmware Version 1.91a1
8. FCode Value 1.50a4
9. Driver Version 6.02e
10. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
11. Fujitsu requires that all patches for Solaris 9 be obtained through Fujitsu in the form of a Solaris 9 PTF patch CD. The current patch CD is Solaris 9 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 9: 112233−12, 112834−06, 113277−45, 117171−17, 118558−30, and PTF R06081
12. For use in Asia Pacific/Japan only. Refer to Fujitsu Siemens Base Connectivity information for US/Europe.
13. Fujitsu requires all patches for Solaris 8 be obtained through Fujitsu in the form of a Solaris 8 PTF patch CD. The current patch CD is Solaris 8 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 8: 108528−29, 117000−05, 108974−50,109885−20, 110918−06, 117350−39 and PTF R06081
14. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
15. Firmware Version 1.90a4
16. Driver Version SAN in Solaris 10 U1 (01/06)
17. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
18. Fujitsu requires all patches for Solaris 10 be obtained through Fujitsu in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers
running Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
19. Use the Solaris 10 bundled driver PFCA 3.0 which requires patch 120811−02. PFCA Utility 3.0 and its patch 914180−01 need to be installed.
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
140 IBM xSeries: x3800/x260 (8865)52, x3950/x3950E/x460 Microsoft PCI−X51 Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4, 41 See1
(8872, 8874)52 Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
141 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 Emulex LP982−E2, 6, 7, 8, 10, 11, 18 FC−AL, EMC Y3, 4 See1
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
142 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 QLogic QLA2340−E−SP10, 13, 14, 27, 48 FC−AL, EMC Y3, 4 See16
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
143 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
144 HPQ Proliant: DL380(G4)12, DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LPe1150−E2, 6, 7, 8, 42 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
145 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LPe1150−E2, 6, 7, 8, 42 FC−AL, EMC Y3, 4, 17 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
146 HPQ Proliant DL380(G4)12 Microsoft PCI, PCI Emulex: LP1050Ex−E2, 6, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
Windows 2000: Express, LPe111−E2, 6, 10, 35, 36, 37 FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
147 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)2, 6, FC−AL, EMC Y3, Y3,
Windows 2000: Express, 7, 8, 42, AE311A/FC1142SR (QLE2460)6, FC−SW CLARiiON 17
Advanced PCI−X 10, 13, 14, 38 AX150
Server SP49,
Server SP4
148 Dell PowerEdge: 1800, 1850; Microsoft PCI, Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000: PCI−X FC−SW CLARiiON
HPQ Proliant: DL14512, DL380(G4)12, DL38512, Advanced AX150
DL580(G2)12, DL580(G3)12, DL58512, ML350(G3)12, Server SP49,
ML370(G3)12, ML370(G4)12; Server SP4
IBM: eServer 325 (Model 8835), xSeries x345 (8670)61,
xSeries x445 (8870);
Samsung SS140
163 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, 17 See16
Windows 2000: Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server SP4,
Server SP4
164 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y See29
Windows 2000: (26R0890)6, 13, 14, 67 CLARiiON
IBM BladeCenter LS20 (Model 8850) Advanced AX150
Server SP4,
Server SP4
165 Intel SBXD62 Blade Server Microsoft PCI−X Intel: SBEFCM (SFF) Mezzanine HBA6, FC−SW EMC Y
Windows 2000: 10, 13, 14, 34 , SBEFCM4 (SFF) 4Gb CLARiiON
Advanced Mezzanine HBA6, 10, 14, 67, 81 AX150
Server SP4,
Server SP4
166 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See1
Windows 2000: Express Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON Y3, 4, 17
Advanced AX150
Server SP49,
Server SP4
167 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, 17 See1
Windows 2000: Express AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server SP49,
Server SP4
168 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, 17 See1
Windows 2000: Express, Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX150
SR4850HW4/SR6850HW4; Server SP49,
Server SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
169 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM Emulex LP1005DC FC Exp Card2, 6, FC−SW EMC Y See29
8832)29, 8832−N1X), 8843); Windows 2000: 7, 8, 10, 71 CLARiiON
Advanced AX150
IBM BladeCenter HS40 (Model 8839) Server SP49,
Server SP4
170 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC Y See29
8832)29, 8843); Windows 2000: (26R0884)6, 13, 14, 67 CLARiiON
Advanced AX150
IBM BladeCenter: HS40 (Model 8839), LS20 (Model Server SP49,
8850) Server SP4
171 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM HS20 FC Exp Card (13N2203)10, 13, FC−SW EMC Y See29
8832)29, 8832−N1X); Windows 2000: 14, 27, 30 CLARiiON
Advanced AX150
IBM BladeCenter HS40 (Model 8839) Server SP49,
Server SP4
172 IBM BladeCenter HS20 (Model: 7981), 8843) Microsoft PCI−X IBM HS20 FC Exp Card (13N2203)10, 13, FC−SW EMC Y See29
Windows 2000: 14, 27, 30, 66 CLARiiON
Advanced AX150
Server SP49,
Server SP4
173 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft PCI−X IBM HS20 FC Exp Card (26K4841)10, 13, FC−SW EMC Y See29
Windows 2000: 14, 27, 30, 58 CLARiiON
IBM BladeCenter LS20 (Model 8850) Advanced AX150
Server SP49,
Server SP4
174 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM HS20 FC Exp Card (48P7061)6, 10, FC−SW EMC Y See29
8832)29, 8843); Windows 2000: 13, 14, 27 CLARiiON
Advanced AX150
IBM BladeCenter HS40 (Model 8839) Server SP49,
Server SP4
1. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
2. BIOS 1.70a3
3. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
4. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
5. Firmware Version 2.10a10
6. SNIA HBA API Supported.
7. Driver Version 2.40a3 SCSI FC Port driver
8. Driver Version 2.41a1 SCSI FC Port driver
9. Windows 2000 hosts running less than SP4 could be susceptible to data loss during LUN expansion operations. This issue is corrected by Microsoft in SP4, or by applying hotfix
327020. See EMC Solution IS emc73538 and Microsoft Knowledge Base article 327020 for more information.
10. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
11. Firmware Version 1.91a5
12. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
13. Driver Version 9.1.2.10
14. Driver Version 9.1.2.11
15. BIOS 1.05
16. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
17. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
18. The Emulex LP9XXX HBA family requires a host PCI bus capable of supplying 3.3 VDC bus power. The PCI slot can use either 3.3 VDC or 5.0 VDC signaling interfaces.
19. For external boot configurations running EMC Powerpath on Windows 2000, HP Proliant BL30p & BL35p require a minimum of Powerpath version 4.4.1.
20. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
21. BIOS 1.45
22. Not supported with Emulex LP8000−EMC HBA.
23. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
24. For AX100 configurations, only Dell PowerVault systems with dual CPUs are supported.
25. BIOS 1.23
26. Driver Version 9.1.2.10 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
122 Dell PowerEdge: 2900, 2950, 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP6, 9, 12, 36 FC−AL, EMC Y1, 15 See26
[x64] Storage Server: Express, FC−SW CLARiiON
Enterprise Edition R2, PCI−X AX150
Standard Edition R2
123 Dell PowerEdge: 2900, 2950 Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP9, 12, 19, FC−AL, EMC Y1, 15 See26
[x64] Storage Server: Express, QLE220−E−SP6, 9, 27, 28 , FC−SW CLARiiON
Enterprise Edition R2, PCI−X QLE2360−E−SP9, 12, 35 AX150
Standard Edition R2
124 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X23 Emulex: LP101−E4, 9, 34, 48, 51 , FC−AL, EMC Y1, 15 See14
8874)24 [x64]: DataCenter, LP1050−E4, 7, 8, 9, 34 , LP1050−E4, 9, 34, 48, FC−SW CLARiiON
DataCenter R211 49, 50, LP982−E4, 7, 8, 9, 34 , LP982−E4, 9, 34, AX150
48, 49, 50
125 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X23 IBM 19K1246: (QLA2310)9, 12, 17, 18, 19 , FC−AL, EMC Y1
8874)24 [x64]: DataCenter, (QLA2310)9, 17, 19, 43, 44, 45 ; FC−SW CLARiiON
DataCenter R211 AX150
IBM 24P0960: (QLA2340)9, 12, 18, 19, 37 ,
(QLA2340)9, 19, 37, 43, 44, 45
126 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X23 QLogic: QLA2340−E−SP9, 12, 18, 19 , FC−AL, EMC Y1, 15 See26
8874)24 [x64]: DataCenter, QLA2340−E−SP9, 19, 43, 45 FC−SW CLARiiON
DataCenter R211 AX150
127 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)4, 34, 41, FC−AL, EMC Y
[x64]: DataCenter, 42 FC−SW CLARiiON
Enterprise Edition, AX150
Standard Edition
128 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)4, 34, 46, FC−AL, EMC N
[x64]: DataCenter, PCI−X 47 FC−SW CLARiiON
Enterprise Edition, AX150
Standard Edition,
Standard Edition R211
129 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
130 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See26
[x64] Enterprise: Edition, Express Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Edition R211; AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
131 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Edition R211; AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
132 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y1, 2, 15, See26
[x64] Enterprise: Edition, Express AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Edition R211; AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
133 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Intel: SR4850HW4−M/SR6850HW4−M, Edition R211; PCI−X AX150 Y1, 15, 20
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x64] Standard: Edition,
G5, T650 Edition R211
134 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See26
[x64] Enterprise: Edition, Express, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Intel: SR4850HW4−M/SR6850HW4−M, Edition R211; PCI−X AX150 Y1, 15, 20
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x64] Standard: Edition,
G5, T650 Edition R211
135 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y1
[x64] Enterprise: Edition, port: for NovaScale Blade Series CLARiiON
Edition R211; CFSN202−11009, 12, 18, 31 , mini for AX150
NovaScale Blade 2021 CFSN202−21009,
Microsoft Windows 2003 12, 18, 31 ;
[x64] Standard: Edition,
Edition R211 Bull: SBEFCM (SFF) Mezzanine HBA6, 9,
12, 18, 31 , SBEFCM4 (SFF) 4Gb Mezzanine
HBA6, 9, 12, 68, 74
136 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 15 See26
[x64] Enterprise: Edition, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
9 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27 See23
8874)42 [x86] DataCenter: R21, SP1 QLA2340−E−SP9, 18, 19, 82 FC−SW CLARiiON
AX150
10 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] DataCenter: R21, 108, 125 FC−SW CLARiiON
SP111 AX150
11 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/540 [x86] DataCenter: R21, 100, 126 FC−SW CLARiiON
SP111 AX150
12 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX: (LP1050)3, FC−AL, EMC Y2
[x86] DataCenter: R21, 123, 127, (LP1050)3, 125 FC−SW CLARiiON
SP111 AX150
13 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y
[x86] DataCenter: R21, 121, 122, 123 FC−SW CLARiiON
SP111; AX150
Microsoft Windows 2003
[x86] Enterprise Edition
SP111
14 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y2
[x86] DataCenter: R21, PCI−X 134, 138 FC−SW CLARiiON
SP111; AX150
Microsoft Windows 2003
[x86]: Enterprise Edition
R21, Standard Edition R21
15 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y
[x86] DataCenter: R21, 121, 122 FC−SW CLARiiON
SP111; AX150
Microsoft Windows 2003
[x86]: Enterprise Edition
SP111, Standard Edition
SP111
16 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, 133 FC−AL, EMC Y2
[x86] DataCenter12 FC−SW CLARiiON
AX150
17 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/540 [x86] DataCenter12 100, 140 FC−SW CLARiiON
AX150
18 NEC Express 5800 320Ma46, 81 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 14, 18, 28, 65, FC−AL, EMC Y2 See23
[x86] Enterprise Edition 80 FC−SW CLARiiON
AX150
19 Stratus ftServer: 430046, 460046 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 18, 28, 65, 80, FC−AL, EMC N See23
[x86] Enterprise Edition 93 FC−SW CLARiiON
AX150
20 Stratus ftServer: 230043, 330038, 430046, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 39, 77, 78 , FC−AL, EMC N See23
460046, 560038, 660038 [x86] Enterprise Edition QLA210−E−SP4, 30, 31, 39 FC−SW CLARiiON
AX150
21 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
BL465c (403433−B21), BL465c [x86] Enterprise Edition Express HP c−Class Bladesystem FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), (403619−B21)29, 71, 72 AX150
BL465c (407235−B21), BL480c
(404704−B21)
22 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 14, 18, 28, 65, FC−AL, EMC Y2 See23
[x86] Enterprise Edition 80 FC−SW CLARiiON
AX150
23 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 14, 18, 28, 65, FC−AL, EMC N See23
[x86] Enterprise Edition 80, 93 FC−SW CLARiiON
AX150
24 Stratus ftServer: 430046, 460046 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 18, 65, 80, 82, FC−AL, EMC N See23
[x86] Enterprise Edition SP1 93 FC−SW CLARiiON
AX150
25 NEC Express 5800 320Ma46, 81 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 9, 18, 65, 80, 82 FC−AL, EMC Y2 See23
[x86] Enterprise Edition SP1 FC−SW CLARiiON
AX150
26 Stratus ftServer 5700 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 9, 18, 65, 80, 82, FC−AL, EMC N See23
[x86] Enterprise Edition SP1 93 FC−SW CLARiiON
AX150
27 Stratus ftServer: 230043, 330038, 430046, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 44, 77, 78 , FC−AL, EMC N See23
460046, 560038, 660038 [x86] Enterprise Edition SP1 QLA210−E−SP4, 30, 31, 44 FC−SW CLARiiON
AX150
28 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 20, 21, 65, FC−AL, EMC Y2 See23
[x86] Enterprise Edition SP1 80 FC−SW CLARiiON
AX150
29 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 20, 21, 65, FC−AL, EMC N See23
[x86] Enterprise Edition SP1 80, 93 FC−SW CLARiiON
AX150
35 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP9, 18, 19, 22, 80, FC−AL, EMC Y2, 27 See23
320Lc−R [x86] Enterprise Edition: 82 FC−SW CLARiiON
R21, SP111 AX150
36 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: 108, 128 FC−SW CLARiiON
R21, SP111 AX150
37 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: 123, 129 FC−SW CLARiiON
R21, SP111 AX150
38 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, 128 FC−AL, EMC Y2
Model 300 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111 AX150
39 Unisys: FS1300, Libra Model 300 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: 100, 123, 129 FC−SW CLARiiON
R21, SP111 AX150
40 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/530, ES7000/540, ES7000/550, [x86] Enterprise Edition: 100, 130 FC−SW CLARiiON
ES7000/560 [32−Bit] R21, SP111 AX150
41 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI Emulex LP101−E3, 18, 49, 50, 60 FC−AL, EMC Y2, 27 See36
DL36034, DL58034, ML350(G2)34, ML35034, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, R21, SP111; AX150
ML530(G3)34, ML53034, ML57034, ML75034;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x340 (4500R), x342, x350 SP111
(6000R), x370
42 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI Emulex LP982−E3, 18, 50, 60, 61, 66 FC−AL, EMC Y2, 27 See36
DL36034, DL58034, ML350(G2)34, ML35034, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, R21, SP111; AX150
ML530(G3)34, ML53034, ML57034, ML75034;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x342, x350 (6000R), x370 SP111
43 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI Emulex: LP101−E3, 6, 18, 56, 60 , FC−AL, EMC Y2, 27 See36
2500, 255040, 4300, 4350, 4400, 6100, 6300, [x86] Enterprise Edition: LP982−E3, 6, 18, 60, 61, 66 FC−SW CLARiiON
6350, 6400, 6450, 8450 R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
44 HPQ Proliant: 850034, DL32034, Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 50, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
DL360(G2)34, DL36034, DL380(G2)34, [x86] Enterprise Edition: LP1150−E3, 4, 18, 49, 50, 61, 75 FC−SW CLARiiON
DL380(G3)34, DL38034, DL58034, R21, SP111; AX150
ML350(G2)34, ML35034, ML370(G2)34,
ML37034, ML530(G2)34, ML530(G3)34, Microsoft Windows 2003
ML53034, ML57034, ML75034; [x86] Standard Edition: R21,
SP111
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
45 Dell PowerEdge: 1550, 2450, 2500, 255040, Microsoft Windows 2003 PCI Emulex: LP1050−E3, 6, 18, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
4400, 6350, 6400, 645097, 8450 [x86] Enterprise Edition: LP1150−E3, 4, 6, 18, 56, 61, 75 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
46 Fujitsu Siemens Primergy: BX60098, BX620 Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q4, 18, 19, FC−AL, EMC Y2
S2F104, BX620 S2104, BX620 S3, BX620104, [x86] Enterprise Edition: 94, 95 FC−SW CLARiiON
BX630 (2−way), BX630 (4−way), BX630 R21, SP111; AX150
(8−way), BX660104
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
47 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI HPQ: A7298A (LP982)3, 18, 49, 50, 60, 61 , FC−AL, EMC Y2
DL36034, DL380(G2)34, DL380(G3)34, [x86] Enterprise Edition: A7388A (LP1050)3, 18, 49, 50, 60, 61 , FC−SW CLARiiON
DL38034, DL58034, ML350(G2)34, ML35034, R21, SP111; AD167A/FC2143 (LP1150)3, 4, 49, 50, 61, AX150
ML370(G2)34, ML37034, ML530(G2)34, 112, FCA2214 (QLA2340)18, 19, 20, 21, 22 ,
ML53034, ML57034, ML75034 Microsoft Windows 2003 FCA2408 (LP982)3, 4, 18, 49, 50, 60, 61
[x86] Standard Edition: R21,
SP111
190 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP14, 18, 19, 22, 28, FC−AL, EMC Y2, 27 See23
320Lc−R [x86] Enterprise Edition12 80 FC−SW CLARiiON
AX150
191 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, 133 FC−AL, EMC Y2
Model 300 [x86] Enterprise Edition12 FC−SW CLARiiON
AX150
255 Dell PowerEdge 1950 Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 53, 60, 61 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express LP982−E3, 18, 58, 60, 61 FC−SW CLARiiON
Standard Edition12 AX150
256 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express 61, LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition12 AX150
HPQ Proliant: DL360(G4)34, DL380(G4)34,
DL580(G3)34;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
257 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express 61, LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−SW CLARiiON
HPQ Proliant: DL360(G4)34, DL380(G4)34, Standard Edition12 AX150
DL580(G3)34;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
258 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 60, 61 , FC−AL, EMC Y2, 27 See36
2850, 6800, 6850 [x86]: Enterprise Edition12, Express LPe1150−E3, 4, 7, 13, 18, 61 FC−SW CLARiiON
Standard Edition12 AX150
259 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)3, 4, 13, 18, 53, FC−AL, EMC Y2, Y2,
[x86]: Enterprise Edition12, Express 61 FC−SW CLARiiON 59
Standard Edition12 AX150
260 HPQ Proliant: DL360(G4)34, DL380(G4)34, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, Y2,
DL580(G3)34 [x86]: Enterprise Edition12, Express 7, 13, 53, 61 FC−SW CLARiiON 59
Standard Edition12 AX150
261 HPQ Proliant: DL360(G4)34, DL380(G4)34 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)4, FC−AL, EMC Y2, Y2,
[x86]: Enterprise Edition12, Express 14, 18, 28, 65, 109 FC−SW CLARiiON 59
Standard Edition12 AX150
262 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)3, 7, 55, 57, 58 FC−AL, EMC Y2, 27 See36
120Ri−2, 140Hf, 140Re−4 [x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
263 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)3, 7, 55, 57, 58 FC−AL, EMC Y2, 27, 54 See23, 36
[x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
264 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 33, 39, 77, 78 FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
265 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP4, 18, 24, 25, 29 FC−AL, EMC Y2, 27 See23
2850, 6800, 6850; [x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
Digital Henge INNO: HR−4850, HR−6850;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
319 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ AE311A/FC1142SR (QLE2460)4, FC−AL, EMC Y2, 41
[x86]: Enterprise Edition12, 14, 18, 28, 65, 109 FC−SW CLARiiON
Standard Edition12 AX150
320 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86]: Enterprise Edition12, for HP Proliant BL25p/BL45p FC−SW CLARiiON
Standard Edition12 381881−B2114, 18, 22, 28, 102 AX150
321 HPQ Proliant: DL360(G3)34, DL360(G4)34, Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)3, 13, 18, 53, 60, 61 , FC−AL, EMC Y2
DL56034, DL74034, DL760 (G2)34, DL76034, [x86]: Enterprise Edition12, A7388A (LP1050)3, 13, 18, 53, 60, 61 , FC−SW CLARiiON
ML570(G2)34 Standard Edition12 AD167A/FC2143 (LP1150)3, 4, 13, 53, 61, AX150
112, FCA2214 (QLA2340)14, 18, 19, 22, 28 ,
FCA2408 (LP982)3, 4, 13, 18, 53, 60, 61
322 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, Y2,
[x86]: Enterprise Edition12, 7, 13, 53, 61 , AE311A/FC1142SR FC−SW CLARiiON 59
Standard Edition12 (QLE2460)4, 14, 18, 28, 65, 109 AX150
323 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 18, 65; AX150
QLogic: QLE220−E−SP4, 18, 24, 25, 29 ,
QLE2360−E−SP18, 22, 62, 67, 68 ,
QLE2460−E−SP4, 14, 18, 22, 28, 65
340 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27, 41 See36
[x86]: Enterprise Edition12, LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
Standard Edition12 13, 18, 58, 60, 61 AX150
351 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X99 QLogic: QLA2340−E−SP14, 18, 19, 28 , FC−AL, EMC Y2, 27, See23
[x86]: Enterprise Edition12, QLA2460−E−SP4, 14, 18, 22, 28, 65 FC−SW CLARiiON Y2, 27, 59
Standard Edition12 AX150
352 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M10, 14, 18, 19 , LPe1105−M3, 4, FC−AL, EMC Y2
[x86]: Enterprise Edition12, Express, 5, 7, 13, QME24624, 8, 10, 14 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
353 HPQ Proliant DL380(G4)34 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E3, 4, 13, 18, 53, 60, 61 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
354 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LP1150−E3, 4, 13, 18, 53, 61, 75 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
355 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E3, 4, 13, 15, 18, 37 FC−AL, EMC Y2, 27 See36
HPQ Proliant DL380(G4)34 [x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
356 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 18, 53, 83 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
357 HPQ Proliant: DL380(G4)34, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−AL, EMC Y2, 27 See36
DL580(G4) [x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
358 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
359 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E3, 4, 13, 15, 18, 37 , FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, LPe1150−E3, 4, 18, 53, 83 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
360 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2
[x86]: Enterprise Edition12, Express, 7, 13, 53, 61 , AD167A/FC2143 (LP1150)3, FC−SW CLARiiON
Standard Edition12 PCI−X 4, 13, 53, 61, 112 , AE311A/FC1142SR AX150
(QLE2460)4, 14, 18, 28, 65, 109
361 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, 59
[x86]: Enterprise Edition12, Express, 7, 13, 53, 61 , AE311A/FC1142SR FC−SW CLARiiON
Standard Edition12 PCI−X (QLE2460)4, 14, 18, 28, 65, 109 AX150
362 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 PCI−X 18, 65; AX150
QLogic QLA2460−E−SP4, 14, 18, 22, 28,
65
363 HPQ Proliant DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP4, 18, 24, 25, 29 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
364 HPQ Proliant: DL380(G4)34, DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP18, 22, 62, 67, 68 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
365 HPQ Proliant: DL380(G4)34, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27 See23
DL580(G3)34, DL580(G4) [x86]: Enterprise Edition12, Express, 65 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
366 HPQ Proliant: DL380(G5), DL580(G3)34, Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27, See23
DL580(G4) [x86]: Enterprise Edition12, Express, 65 FC−SW CLARiiON 41, Y2,
Standard Edition12 PCI−X AX150 27, 59
368 Fujitsu Siemens Primergy: RX600, TX600 Microsoft Windows 2003 PCI, Emulex LP1050−E3, 18, 53, 100 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, PCI−X FC−SW CLARiiON
Standard Edition12 AX150
369 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
DL380(G3)34, DL380(G4)34, DL38034, [x86]: Enterprise Edition12, PCI−X LP1050−E3, 13, 18, 53, 60, 61 , LP1150−E3, FC−SW CLARiiON
DL38534, DL580(G2)34, DL580(G3)34, Standard Edition12 4, 13, 18, 53, 61, 75 , LP982−E3, 13, 18, 58, AX150
DL58534, ML350(G3)34, ML370(G3)34, 60, 61
ML370(G4)34;
IBM: eServer 325 (Model 8835), xSeries x345
(8670), xSeries x445 (8870);
Samsung SS140
370 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, Emulex: LP101−E3, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, PCI−X LP1050−E3, 18, 53, 60, 61 , LP982−E3, 18, FC−SW CLARiiON
Standard Edition12 58, 60, 61 AX150
371 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)3, 13, 18, 53, 60, 61 , FC−AL, EMC Y2
DL380(G3)34, DL380(G4)34, DL38034, [x86]: Enterprise Edition12, PCI−X A7388A (LP1050)3, 13, 18, 53, 60, 61 , FC−SW CLARiiON
DL38534, DL580(G2)34, DL58534, Standard Edition12 AD167A/FC2143 (LP1150)3, 4, 13, 53, 61, AX150
ML350(G3)34, ML370(G3)34, ML370(G4)34 112, FCA2214 (QLA2340)14, 18, 19, 22, 28 ,
FCA2408 (LP982)3, 4, 13, 18, 53, 60, 61
372 HPQ Proliant: DL380(G4)34, DL38534, Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
DL58534, ML370(G4)34 [x86]: Enterprise Edition12, PCI−X 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 18, 65 AX150
373 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
(8670), xSeries x445 (8870) [x86]: Enterprise Edition12, PCI−X 120 FC−SW CLARiiON
Standard Edition12 AX150
374 IBM xSeries: x345 (8670), x445 (8870) Microsoft Windows 2003 PCI, IBM 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−AL, EMC Y2
[x86]: Enterprise Edition12, PCI−X 103 FC−SW CLARiiON
Standard Edition12 AX150
375 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM: 39M5894 (QLA2460)4, 18, 22, 65, 73 , FC−AL, EMC Y2, 27 See23
(8670), xSeries x445 (8870) [x86]: Enterprise Edition12, PCI−X 39M5895 (QLA2462)4, 18, 22, 65, 73 FC−SW CLARiiON
Standard Edition12 AX150
376 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP18, 19, 96 FC−AL, EMC Y2, 27 See23
TX600 [x86]: Enterprise Edition12, PCI−X FC−SW CLARiiON
Standard Edition12 AX150
377 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 33, 39, 77, FC−AL, EMC Y2, 27 See23
DL380(G3)34, DL380(G4)34, DL38034, [x86]: Enterprise Edition12, PCI−X 78, QLA210−E−SP4, 30, 31, 33 , FC−SW CLARiiON
DL38534, DL580(G2)34, DL580(G3)34, Standard Edition12 QLA2340−E−SP14, 18, 19, 28 , AX150
DL58534, ML350(G3)34, ML370(G3)34, QLA2460−E−SP4, 14, 18, 22, 28, 65
ML370(G4)34;
IBM: eServer 325 (Model 8835), xSeries x345
(8670), xSeries x445 (8870);
Samsung SS140
378 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 39, 79 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, PCI−X QLA210−E−SP4, 30, 33, 35 , FC−SW CLARiiON
Standard Edition12 QLA2340−E−SP10, 14, 18, 19 AX150
379 Unisys ES7000/460 [32−Bit] Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86]: Enterprise Edition12, PCI−X 100, 131 FC−SW CLARiiON
Standard Edition12 AX150
380 Bull NovaScale: 2021, 2040, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y2
[x86] Enterprise Edition: port for NovaScale Blade Series CLARiiON
R21, SP1; CFSN202−110018, 20, 21, 22, 107 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP1
381 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y2
[x86] Enterprise Edition: port mini for NovaScale Blade 2021 CLARiiON
R21, SP1; CFSN202−210018, 20, 21, 22, 107 , AX150
SBEFCM (SFF) Mezzanine HBA4, 18, 20,
Microsoft Windows 2003 21, 22, 107 , SBEFCM4 (SFF) 4Gb
[x86] Standard Edition: R21, Mezzanine HBA4, 9, 18, 92, 110
SP1
382 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA4, FC−SW EMC Y2
[x86] Enterprise Edition: 9, 18, 82, 107 , SBEFCM4 (SFF) 4Gb CLARiiON
R21, SP1; Mezzanine HBA4, 9, 18, 92, 110 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP1
383 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86] Enterprise Edition: Express Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27,
R21, SP111; 70 AX150 41, Y2,
27, 59
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
384 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See36
[x86] Enterprise Edition: Express Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27, 59
R21, SP111; 70 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
403 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27, 59
Standard Edition12 70 AX150
404 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express AHWFCMOD4, 14, 18, 22, 28, 69, 70 CLARiiON Y2, 27,
Standard Edition12 AX150 41, Y2,
27, 59
405 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express AHWFCMOD4, 14, 18, 22, 28, 69, 70 CLARiiON Y2, 27, 59
Standard Edition12 AX150
406 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express, Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27,
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition12 PCI−X 70 AX150 41, Y2,
SR4850HW4/SR6850HW4; 27, 59
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
11. Supports LUNs greater than 2TB in size. Minimum Service Pack 1 (SP1) required.
12. Maximum supported LUN size is 2TB for Windows 2003 without Service Pack 1 (SP1.)
13. Driver Version 1.20a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
14. Driver Version 9.1.2.16 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
15. Firmware Version 2.50a8
16. Driver Version 1.20a3
17. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
18. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
19. BIOS 1.47
20. Driver Version 9.1.2.16 STORPort Miniport Driver
21. Driver Version 9.1.2.15 STORPort Miniport Driver
22. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
23. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
24. BIOS 1.02
25. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
26. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
27. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
28. Driver Version 9.1.2.15 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
29. Driver Version 9.1.2.19 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
30. BIOS 1.23
31. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. SCSI Miniport (SCSIPort) Driver
32. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
33. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
34. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
35. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. This driver requires Microsoft SCSIPort hotfix Q883114. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];883114 SCSI Miniport (SCSIPort) Driver
36. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
37. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI FC Port driver As of 2.40a2 Microsoft will no longer allow the
Emulex Port Driver to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO
solution and block submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
38. Supports Stratus OS 3.1.x.
39. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
40. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
41. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar
SCSI.)
42. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
43. Requires Stratus OS 3.1
44. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
45. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
46. Supports Stratus OS 4.1 FTSSS Release
47. BIOS 1.45
48. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
49. Driver Version 1.11a3 STORPort Miniport Driver
50. Driver Version 1.20a3 STORPort Miniport Driver
51. Firmware Version 1.91a2
52. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. STORPort Miniport Driver
53. Driver Version 1.11a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
54. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
55. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
56. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
57. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
58. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
59. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
60. Firmware Version 1.91a5
61. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver
to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
62. BIOS 1.05
63. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
64. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
65. BIOS 1.08
66. Driver Version 1.11a3
67. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
68. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
69. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
70. BIOS 1.06
71. Driver Version 9.1.2.14
72. BIOS 1.16
73. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com STORPort Miniport Driver Requires
Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
74. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com Requires Microsoft STORPort hotfix
Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently requires Service Pack 1 (SP1) to be installed before the hotfix
can be installed. STORPort Miniport Driver
75. Firmware Version 2.10a10
76. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
77. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
78. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
79. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
80. QLogic SANSurfer/SANBlade Manager is not supported. Use QLogic SANCLI utility.
81. 3.2Ghz and 3.6Ghz versions of this server are supported.
82. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
83. Firmware Version 2.50a4
84. Firmware Version 1.90a5
85. BIOS 1.71a0
86. Mixing 2Gb and 4Gb fibre channel expansion cards is not supported in this server.
87. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
88. Internal port(s) on QLogic or McData 4Gb FC switch module(s) must be set to 4Gb to SAN boot.
89. Refer to EMC Knowledgebase ID emc105679 for any special HBA drivers that may be required.
90. Due to the HS20's embedded FC−SW design, array lun masking is required to assign LUNS to each individual blade server.
91. Dual−port FC switch module. Can be used in place of Optical PassThru Module (OPM.)
92. BIOS 1.12
93. Please read Stratus CAC Alert 2300 prior to the installation of QLA2460−E−SP HBAs.
94. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
95. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
96. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
97. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
98. BX600 uses an embedded fibre channel controller. Contact Fujitsu Siemens to acquire proper BIOS for embedded fibre channel controller.
99. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
100. Firmware Version 1.91a1
101. Driver Version 9.1.2.15
102. BIOS 1.48
103. This HBA is equivalent to the QLogic QLA2340.
104. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
105. Accepts PCI−X 1.0 and 2.0 HBAs.
106. Driver Version 9.1.2.10 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
107. BIOS 1.43
108. Firmware Version 1.90a4
109. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. SCSI Miniport (SCSIPort) Driver
110. Driver Version 9.1.2.11
111. Driver Version 9.1.2.10 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
112. Firmware Version 2.10a9
113. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
114. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
115. QLogic SanBlade Manager is not supported.
116. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
117. Supports Stratus OS 2.0.X through 2.1.X.
118. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
119. Supports Stratus OS 1.3.X through 2.1.X.
120. This HBA is equivalent to the QLogic QLA2310.
121. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
122. Driver Version 1.10x1
123. RPQ or Unisys Custom Engineering Request (CER) required.
124. Driver Version 1.10a4 STORPort Miniport Driver
125. Driver Version 1.02a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
126. Driver Version 1.10a4 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
127. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
128. Driver Version 1.02a3 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
129. Driver Version 1.11a1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
130. Driver Version 1.11u1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
131. Driver Version 1.11u1 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
132. Driver Version 1.11a1 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
133. Driver Version 1.02a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
134. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
135. Driver Version 1.10x1 Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
136. Driver Version 1.10x1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
137. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
138. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
139. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
140. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
141. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
142. Driver Version 1.11u1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
Novell Netware
Novell Netware
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5 SP314, 15 Express QLE2360−E−SP18, 19, 24, FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL380(G4)16, DL580(G3)16, ML370(G4)16; 25 AX1501, 2,
3, 4, 5, 6, 7,
IBM xSeries x336 (8837)21 8, 9, 10, 11,
12, 13
2 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5 SP314, 15 Express QLE2460−E−SP18, 19, 22 FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL580(G3)16, ML370(G4)16 AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
3 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5 SP314, 15 QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX200 S2, RX300, RX300 S2, AX1501, 2,
TX150, TX200, TX200 S2, TX300, TX300 S2; 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016,
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
4 Fujitsu Siemens Primergy RX300 S2 Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5 SP414 QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
5 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5 SP414, 15 QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX300, TX150, TX200, TX300; AX1501, 2,
3, 4, 5, 6, 7,
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016, 8, 9, 10, 11,
12, 13
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
6 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255023, 4300, 4350, 4400, Novell Netware PCI QLogic: QLA200−E−SP17, FC−AL, EMC Y
6100, 6300, 6350, 6400, 6450, 8450; 6.5: SP314, 15, 18, 19, QLA2340−E−SP18, FC−SW CLARiiON
SP414, 15, 19, 20 AX1501, 2,
HPQ Netserver LC: 2000 U3, 2000r; SP4a14, SP514 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
HPQ Netserver LH: (LH Pro), 3, 300028, 4, 6000/LH 6000r, II, PRO, lll;
HPQ Netserver: LP 2000r, LT 6000R, LX PRO, LXR 8000, LXR 8500, LXR
PRO, LXR PRO8;
HPQ Proliant: 160016, 185016, 250016, 300016, 500016, 550016, 600016, 6400R,
650016, 700016, 800016, 850, 850016, DL32016, DL360(G2)16, DL36016,
DL58016, ML350(G2)16, ML35016, ML370(G2)16, ML37016, ML530(G2)16,
ML530(G3)16, ML53016, ML57016, ML75016;
IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20, 5600, 6000R, 7000,
7000 M1027, 7100, 7600, 8500, 8500R;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335, x340 (4500R), x350
(6000R)
7 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP17, FC−AL, EMC Y
6.5: SP314, 15, 18, 19 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX300, TX150, TX200, TX300; SP414, 15, AX1501, 2,
SP4a14, SP514 3, 4, 5, 6, 7,
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016, 8, 9, 10, 11,
12, 13
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
8 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI, QLogic: QLA200−E−SP17, FC−AL, EMC Y
6.5: SP314, 15, PCI−X 18, 19, QLA2340−E−SP18, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX600, TX600; SP414, 15, 19, 20 AX1501, 2,
SP4a14, SP514 3, 4, 5, 6, 7,
HPQ Proliant: DL360(G4)16, DL380(G2)16, DL380(G3)16, DL380(G4)16, 8, 9, 10, 11,
12, 13
DL38016, DL580(G2)16, DL580(G3)16, ML350(G3)16, ML370(G3)16,
ML370(G4)16;
IBM xSeries: x342, x345 (8670), x360, x365, x370, x440, x445 (8870);
Samsung SS140
9 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5: SP414, 15, Express QLE2360−E−SP18, 19, 24, FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL380(G4)16, DL580(G3)16, ML370(G4)16; SP4a14, SP514 25 AX1501, 2,
3, 4, 5, 6, 7,
IBM xSeries x336 (8837)21 8, 9, 10, 11,
12, 13
Novell Netware
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
10 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic: QLA200−E−SP17, FC−AL, EMC Y
6.5: SP414, 15, Express, 18, 19, QLA2340−E−SP18, FC−SW CLARiiON
SP4a14, SP514 PCI−X 19, 20, QLE2360−E−SP18, AX1501, 2,
19, 24, 25 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
11 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5: SP414, Express QLE2460−E−SP18, 19, 22 FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL580(G3)16, ML370(G4)16 SP4a14, SP514 AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
12 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic FC−AL, EMC Y
6.5: SP414, Express, QLE2460−E−SP18, 19, 22 FC−SW CLARiiON
SP4a14, SP514 PCI−X AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
13 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5: SP4a14, QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX300, RX300 S2, TX150, TX200, SP514 AX1501, 2,
TX300; 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016,
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
1. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
2. No MirrorView or SnapView used on boot LUNs.
3. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
4. Novell Storage Services supported.
5. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
6. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After Abend".
When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
7. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
8. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any found in
previous boot documentation.
9. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
10. Remote boot not supported with PERC controllers enabled in system BIOS.
11. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
12. Edit config.sys with the following: Files=100, Buffers=99
13. Supports eight (8) hosts per array.
14. Novell OES is supported on this kernel.
15. PowerPath is not supported in conjunction with host−based mirroring.
16. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
17. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. SNIA HBA API Supported.
19. Driver Version 6.90m
20. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
22. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
24. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
25. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
27. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
28. HP Netserver LH3000 U3 is supported in the same configurations as the standard LH 3000.
29. Must use standard PCI 32bit/33MHz slot for SCSI
18 Dell PowerEdge 1950; Oracle Enterprise PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
28 NEC Express 5800: 120Li, 120Rg−1, 120Ri−2, 140Hf, Oracle Enterprise PCI NEC: N8190−120 (LP1050)5, 14, 19, 20 , FC−AL, EMC Y
140Re−4 Linux [32−Bit] 4 U4 Express, N8190−127 (LPe1150)5, 10, 19, 20 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
29 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, Oracle Enterprise PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
6850, 6950; Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550, AS2500;
HPQ Proliant ML350(G4)18;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
30 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise PCI Emulex: LP101−E2, 5, 6, 9, LP1050−E5, 6, 14, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, LP982−E5, 6; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X25 AX150
QLogic: QLA200−E−SP2, 7, 8,
QLA210−E−SP2, 7, 8, QLA2340−E−SP7, 12,
QLE220−E−SP1, 2, 3
31 Dell PowerEdge 1855 Oracle Enterprise PCI−X Dell: 2342M7, 12, LPe1105−M2, 5, 6, 10, FC−AL, EMC Y
Linux [32−Bit] 4 U4 QME24622, 7, 32 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
32 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950, 2600, Oracle Enterprise PCI−X Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
2650, 6600, 6650; Linux [32−Bit] 4 U4 QLogic QLA200−E−SP2, 7, 8 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)18, DL360(G4)18,
DL56018, DL74018, DL760 (G2)18, DL76018, ML570(G2)18;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
48 HPQ Proliant DL380(G5) Oracle Enterprise PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 7, 30, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, AE369A/FC1243 (QLA2462)2, 7, 30 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
49 Dell PowerEdge: 1800, 2800; Oracle Enterprise PCI, PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) v2.6.9−42.0.0.0.1.EL PCI−X AX150
50 HPQ Proliant: DL14518, DL380(G2)18, DL380(G3)18, Oracle Enterprise PCI, Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
DL380(G4)18, DL38018, DL38518, DL580(G2)18, Linux [32−Bit] 4 U4 PCI−X QLogic: QLA200−E−SP2, 7, 8, FC−SW CLARiiON
DL580(G3)18, DL58518, ML370(G3)18, ML370(G4)18; v2.6.9−42.0.0.0.1.EL QLA210−E−SP2, 7, 8, QLE220−E−SP1, 2, 3 AX150
Samsung SS140
51 Dell PowerEdge: 1800, 1850, 2800, 2850; Oracle Enterprise PCI, Emulex: LP1050−E2, 5, 6, 14, LP982−E2, 5, 6; FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model 8848); v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP2, 7, 12 AX150
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
52 HPQ Proliant: DL14518, DL380(G2)18, DL380(G3)18, Oracle Enterprise PCI, Emulex: LP1050−E5, 6, 14, LP982−E5, 6 FC−AL, EMC Y
DL380(G4)18, DL38018, DL38518, DL580(G2)18, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
DL580(G3)18, DL58518, ML370(G3)18, ML370(G4)18 v2.6.9−42.0.0.0.1.EL AX150
53 HPQ Proliant: DL380(G4)18, DL38518, DL58518, Oracle Enterprise PCI, HPQ: AB429A/FC1143 (QLA2460)2, 7, 30, FC−AL, EMC Y
ML370(G4)18 Linux [32−Bit] 4 U4 PCI−X AE369A/FC1243 (QLA2462)2, 7, 30 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
54 IBM eServer: 325 (Model 8835), 326 (Model 8848) Oracle Enterprise PCI, IBM 24P0960 (QLA2340)2, 7, 12, 22 FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
55 HPQ Proliant: DL14518, DL380(G4)18, DL38518, Oracle Enterprise PCI, QLogic QLA2340−E−SP7, 12 FC−AL, EMC Y
DL580(G2)18, DL580(G3)18, DL58518, ML370(G3)18, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
ML370(G4)18; v2.6.9−42.0.0.0.1.EL AX150
Samsung SS140
56 Bull NovaScale 2320 Oracle Enterprise PCI−X Bull 2Gbps FC Mezzanine Card − Dual port FC−SW EMC Y
Linux [32−Bit] 4 U4 for NovaScale Blade Series: CLARiiON
v2.6.9−42.0.0.0.1.EL CFSN202−11007, 13, CFSN202−11007, 21; AX150
Bull 2Gbps FC Mezzanine Card − Dual port
mini for NovaScale Blade 2021:
CFSN202−21007, 13, CFSN202−21007, 21;
Bull SBEFCM (SFF) Mezzanine: HBA2, 7, 21,
HBA7, 13;
Bull SBEFCM4 (SFF) 4Gb Mezzanine HBA7,
15
57 Digital Henge PowerBlade BS200L Oracle Enterprise PCI−X Digital Henge Digital Henge: SBEFCM42, 7, FC−SW EMC Y
Linux [32−Bit] 4 U4 15, SBEFCM7, 13, SBFCM7, 13; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge Intel (r) Fibre Channel Module
AHWFCMOD2, 7, 13
58 IBM BladeCenter: HS20 (Model 8843), HS21 (Model Oracle Enterprise PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)27 Linux [32−Bit] 4 U4 (26R0890)2, 7, 28, 29 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
59 IBM BladeCenter: HS21 (Model 8853)27, LS20 (Model Oracle Enterprise PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8850), LS21 (Model 7971), LS41 (Model 7972) Linux [32−Bit] 4 U4 (26R0890)2, 7, 29 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
60 IBM BladeCenter: HS20 (Model 8843), LS20 (Model 8850), Oracle Enterprise PCI−X IBM HS20 FC Exp Card (26K4841)2, 7, 12 FC−SW EMC Y
LS21 (Model 7971), LS41 (Model 7972) Linux [32−Bit] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
61 IBM BladeCenter HS20 (Model: 7981), 8678)34, 8832)34, Oracle Enterprise PCI−X IBM HS20 FC Exp Card: (13N2203)2, 7, 12, FC−SW EMC Y
8832−N1X), 8843); Linux [32−Bit] 4 U4 (48P7061)2, 7, 12 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
IBM BladeCenter: HS21 (Model 8853)27, HS40 (Model
8839)
19 NEC Express 5800: 120Li, 120Rg−1, Oracle Enterprise Linux PCI NEC: N8190−120 (LP1050)4, 5, 6, 7, N8190−127 FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 [EM64T] 4 U4 Express, (LPe1150)4, 5, 7, 21 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
20 Dell PowerEdge: 1850, 1900, 2850, 2900, Oracle Enterprise Linux PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
2950, 6800, 6850; [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
21 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise Linux PCI Emulex: LP101−E3, 5, 14, 25 , LP1050−E5, 6, 14, FC−AL, EMC Y
[EM64T] 4 U4 Express, LP982−E5, 14; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X13 AX150
QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9,
QLA2340−E−SP8, 10, QLE220−E−SP1, 2, 3, 12
22 Dell PowerEdge 1855 Oracle Enterprise Linux PCI−X Dell: 2342M8, 10, LPe1105−M3, 5, 14, 21 , QME24623, 8, FC−AL, EMC Y
[EM64T] 4 U4 23 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
23 Dell PowerEdge: 1850, 1950; Oracle Enterprise Linux PCI−X Emulex LP101−E3, 5, 14, 25 ; FC−AL, EMC Y
[EM64T] 4 U4 QLogic QLA200−E−SP3, 8, 9 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant DL360(G4)11;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003
24 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise Linux PCI−X Emulex LP101−E5, 14, 25 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−42.0.0.0.1.EL AX150
NF520
25 Dell PowerEdge: 1850, 1950; Oracle Enterprise Linux PCI−X Emulex LP1050−E3, 5, 6, 14; FC−AL, EMC Y
[EM64T] 4 U4 QLogic QLA2340−E−SP3, 8, 10 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX150
IBM xSeries: x255, x336 (8837)35, x346
(8840)35;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230
26 Dell PowerEdge 1850; Oracle Enterprise Linux PCI−X Emulex LP982−E3, 5, 14 FC−AL, EMC Y
Digital Henge INNO: HR−4850, HR−6850; [EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)35, x346
(8840)35;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230
27 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise Linux PCI−X Emulex: LP1050−E5, 6, 14, LP982−E5, 14 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
HPQ Proliant DL360(G4)11; v2.6.9−42.0.0.0.1.EL AX150
LangChao: NC3000, NC3500, NF500,
NF520
28 HPQ Proliant BL460c: (416653−B21), Oracle Enterprise Linux PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y30, 31
(416654−B21), (416655−B21), [EM64T] 4 U4 c−Class Bladesystem (403621−B21)5, 29, 32 FC−SW CLARiiON
(416656−B21), (432636−B21); v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
29 HPQ Proliant BL460c: (416653−B21), Oracle Enterprise Linux PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(416654−B21), (416655−B21), [EM64T] 4 U4 Bladesystem (403619−B21)8, 28 FC−SW CLARiiON
(416656−B21), (432636−B21); v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
39 Dell PowerEdge: 1800, 2800 Oracle Enterprise Linux PCI, PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
40 HPQ Proliant: DL380(G5), DL580(G3)11, Oracle Enterprise Linux PCI, PCI QLogic QLE220−E−SP1, 2, 3, 12 FC−AL, EMC Y
DL580(G4) [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
41 HPQ Proliant: DL380(G4)11, Oracle Enterprise Linux PCI, PCI−X Emulex: LP101−E3, 5, 14, 25 , LP1050−E5, 6, 14, FC−AL, EMC Y
ML370(G4)11 [EM64T] 4 U4 LP982−E5, 14; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
HPQ: AB429A/FC1143 (QLA2460)3, 8, 20,
AE369A/FC1243 (QLA2462)3, 8, 20;
QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9,
QLA2340−E−SP8, 10, QLE220−E−SP1, 2, 3, 12
42 Dell PowerEdge: 1800, 1850, 2800, 2850; Oracle Enterprise Linux PCI, PCI−X Emulex: LP1050−E3, 5, 6, 14, LP982−E3, 5, 14; FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
IBM xSeries: x365, x440, x445 (8870); v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP3, 8, 10 AX150
Samsung: ES470, ES570, SS140
43 IBM BladeCenter HS20 (Model 8843) Oracle Enterprise Linux PCI−X IBM HS20 FC Exp Card (26K4841)3, 8, 10 FC−SW EMC Y
[EM64T] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
44 IBM BladeCenter HS20 (Model: Oracle Enterprise Linux PCI−X IBM HS20 FC Exp Card: (13N2203)3, 8, 10, FC−SW EMC Y
8832−N1X), 8843); [EM64T] 4 U4 (48P7061)3, 8, 10 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
IBM BladeCenter HS21 (Model 8853)17
45 IBM BladeCenter: HS20 (Model 8843), Oracle Enterprise Linux PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
HS21 (Model 8853)17 [EM64T] 4 U4 (39Y9186)3, 5, 15, 16 , HS20 4GB SFF FC Exp Card CLARiiON
v2.6.9−42.0.0.0.1.EL (26R0890)3, 8, 18, 19 AX150
46 IBM BladeCenter HS20 (Model: Oracle Enterprise Linux PCI−X IBM: Emulex LP1005DC FC Exp Card3, 5, 14, 34 , HS20 FC−SW EMC Y
8832−N1X), 8843) [EM64T] 4 U4 4GB Standard FC Exp Card (26R0884)3, 8, 36 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
1. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
2. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
3. SNIA HBA API Supported.
4. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
5. Driver Version 8.0.16.27 Driver is integrated into the kernel.
6. Firmware Version 1.91a5
7. BIOS 1.70a3
8. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
9. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
12. Driver/BIOS are available at http://www.qlogic.com
13. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
14. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
15. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
16. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
17. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
18. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. BIOS 1.12
20. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Firmware Version 2.50a6
22. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
23. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
26. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
27. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
28. BIOS 1.16
29. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
31. VxVM is not supported on servers booting from the array.
32. Firmware Version 2.50a8
33. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
34. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
36. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. This HBA is equivalent to the QLogic QLA2340.
38. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
39. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
1. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. Driver Version 8.0.16.18 Driver is integrated into the kernel.
3. SNIA HBA API Supported.
4. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Native multipathing is not supported on boot−from−SAN configurations.
6. Based on Asianux 2.0.
7. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
8. Driver/BIOS are available at http://www.qlogic.com
9. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
10. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
51 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 32 ; FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 Express QLogic QLE2360−E−SP2, 14, 15, 29 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
52 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LPe111−E1, 2, 25, 32 , FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 Express LPe1150−E1, 2, 17, 32 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
53 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.4.21−40.EL30, 31 Express 27, 32 FC−SW CLARiiON
AX150
54 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLE2460−E−SP2, 18, 29 FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 Express FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
55 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E1, 2, 13, 32 , LP1050−E1, FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, 2, 3, 32, LP982−E1, 2, 32; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX150
AS2500; QLogic: QLA200−E−SP2, 26, 37,
QLA2340−E−SP2, 6, 29
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
56 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E1, 13, 32, LP1050−E1, 3, FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, 32, LP982−E1, 32; FC−SW CLARiiON
PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)2, 8, 29,
AE369A/FC1243 (QLA2462)2, 8, 29;
QLogic: QLA200−E−SP26, 29,
QLA2340−E−SP6, 29, QLE220−E−SP2,
83, 84, 85
57 IBM xSeries: x3550 (7978), x3650 (7979) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP1050−E1, 2, 3, 32, FC−AL, EMC Y66
v2.4.21−40.EL30, 31 Express, LP1050Ex−E1, 2, 13, 32 ; FC−SW CLARiiON
PCI−X AX150
IBM: 24P0960 (QLA2340)2, 6, 16, 29 ,
24P8053 (QLA2342)2, 6, 29, 39M5894
(QLA2460)2, 18, 29, 39M5895
(QLA2462)2, 18, 29;
QLogic: QLA2340−E−SP2, 6, 29,
QLA2460−E−SP2, 18, 29,
QLE2360−E−SP2, 14, 29,
QLE2460−E−SP2, 18, 29
69 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 32 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−40.EL30, 31 FC−SW CLARiiON
140Rd−4 AX150
70 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 23, 27, 32 FC−AL, EMC Y
v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150
78 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 32 , QME24622, FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, 29, 53 FC−SW CLARiiON
PCI−X AX150
79 HPQ Proliant: DL380(G2)9, DL380(G3)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex LP982−E1, 32 FC−AL, EMC Y
DL380(G4)9, DL3809, DL580(G2)9, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL580(G3)9, ML370(G3)9, ML370(G4)9 AX150
80 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E1, 2, 13, 32 , LP1050−E1, FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−40.EL30, 31 PCI−X 2, 3, 32, LP982−E1, 2, 32; FC−SW CLARiiON
AX150
QLogic QLA200−E−SP2, 26, 37
81 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E1, 13, 32, LP1050−E1, 3, FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−40.EL30, 31 PCI−X 32; FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9 QLogic QLA200−E−SP26, 29
82 HPQ Proliant: DL380(G4)9, ML370(G4)9 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 8, 29, FC−AL, EMC Y
v2.4.21−40.EL30, 31 PCI−X AE369A/FC1243 (QLA2462)2, 8, 29 FC−SW CLARiiON
AX150
83 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA210−E−SP2, 26, 29 FC−AL, EMC Y
HPQ Proliant: DL1459, DL380(G2)9, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL380(G3)9, DL380(G4)9, DL3809, DL3859, AX150
DL580(G2)9, DL580(G3)9, DL5859,
ML370(G3)9, ML370(G4)9;
Samsung: ES470, ES570, SS140
84 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 29 FC−AL, EMC Y
Fujitsu Siemens Primergy RX800 S2; v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 AX150
85 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 37 FC−AL, EMC Y
Samsung ES470 v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
AX150
86 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP6, 29 FC−AL, EMC Y
HPQ Proliant: DL380(G2)9, DL380(G3)9, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL380(G4)9, DL3809, DL580(G2)9, AX150
DL580(G3)9, ML370(G3)9, ML370(G4)9
91 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 38 ; FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 Express QLogic QLE2360−E−SP2, 14, 15, 44 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
92 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LPe111−E1, 2, 25, 38 , FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 Express LPe1150−E1, 2, 17, 38 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
93 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.4.21−47.EL30, 31 Express 27, 38 FC−SW CLARiiON
AX150
94 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(403434−B21), (407234−B21), v2.4.21−47.EL30, 31 Express for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)25, 28, 38 AX150
95 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(403434−B21), (407234−B21), v2.4.21−47.EL30, 31 Express HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403619−B21)24, 44 AX150
96 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic QLE2460−E−SP2, 18, 44 FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 Express FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
97 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E1, 2, 13, 38 , LP1050−E1, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 2, 3, 38, LP982−E1, 2, 38; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX150
AS2500; QLogic: QLA200−E−SP2, 26, 44,
QLA2340−E−SP2, 6, 44
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
98 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 38, LP982−E1, 38; FC−SW CLARiiON
PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)2, 8, 44,
AE369A/FC1243 (QLA2462)2, 8, 44;
QLogic: QLA200−E−SP26, 44,
QLA2340−E−SP6, 44, QLE220−E−SP2,
84, 85
99 IBM xSeries: x3550 (7978), x3650 (7979), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP1050−E1, 2, 3, 38, FC−AL, EMC Y66
x3755 (8877) v2.4.21−47.EL30, 31 Express, LP1050Ex−E1, 2, 13, 38 ; FC−SW CLARiiON
PCI−X AX150
IBM: 24P0960 (QLA2340)2, 6, 16, 44 ,
24P8053 (QLA2342)2, 6, 44, 39M5894
(QLA2460)2, 18, 44, 39M5895
(QLA2462)2, 18, 44;
QLogic: QLA2340−E−SP2, 6, 44,
QLA2460−E−SP2, 18, 44,
QLE2360−E−SP2, 14, 44,
QLE2460−E−SP2, 18, 44
112 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 38 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−47.EL30, 31 FC−SW CLARiiON
140Rd−4 AX150
113 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 23, 27, 38 FC−AL, EMC Y
v2.4.21−47.EL30, 31 FC−SW CLARiiON
AX150
122 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 38 , QME24622, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 44, 53 FC−SW CLARiiON
PCI−X AX150
123 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 38, LP982−E1, 38, LPe111−E1, 2, 25, 38 , FC−SW CLARiiON
PCI−X LPe1150−E1, 2, 17, 38 ; AX150
HPQ: A8002A/FC2142SR (LPe1150)1, 2,
27, 38, AE311A/FC1142SR (QLE2460)2,
18, 44, AE312A/FC1242SR (QLE2462)2,
18, 44;
124 HPQ Proliant DL380(G5) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 8, 44, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, AE369A/FC1243 (QLA2462)2, 8, 44 FC−SW CLARiiON
PCI−X AX150
125 HPQ Proliant: DL380(G2)9, DL380(G3)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex LP982−E1, 38; FC−AL, EMC Y
DL380(G4)9, DL3809, DL580(G2)9, v2.4.21−47.EL30, 31 PCI−X QLogic QLA2340−E−SP6, 44 FC−SW CLARiiON
DL580(G3)9, ML370(G3)9, ML370(G4)9 AX150
126 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex: LP101−E1, 2, 13, 38 , LP1050−E1, FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−47.EL30, 31 PCI−X 2, 3, 38, LP982−E1, 2, 38; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP2, 26, 44,
QLA2340−E−SP2, 6, 44
127 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−47.EL30, 31 PCI−X 38; FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9 QLogic QLA200−E−SP26, 44
149 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 80 FC−AL, EMC N11, 47
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
150 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC: N8190−120 (LP1050)1, 13, 23, 54 , FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES N8190−127 (LPe1150)1, 23, 27, 54 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
151 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic QLA210−E−SP2, 26, 29 FC−AL, EMC Y11, 47
2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
HPQ Proliant BL40p;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
152 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic: QLA200−E−SP26, 29, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES QLA210−E−SP2, 26, 29, FC−SW CLARiiON
HPQ Proliant: DL360(G3)9, DL360(G4)9, v2.4.21−37.0.1.EL QLA2340−E−SP6, 29 AX150
DL5609, DL7409, DL760 (G2)9, DL7609,
ML570(G2)9
153 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES Channel Mezzanine HBA − FC−SW CLARiiON
v2.4.21−37.0.1.EL 394757−B211, 54, 55, 56 AX150
154 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES Fibre Channel Mezzanine HBA − FC−SW CLARiiON
v2.4.21−37.0.1.EL 394588−B211, 54, 55, 56 AX150
220 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Dell: 2342M6, 2342M6, 7, LPe1105−M1, 2, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES 17, 51,QME24622, 7, 53 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
221 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES QLogic QLA200−E−SP2, 7, 26 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−22.0.2.EL
9
HPQ Proliant: BL40p, DL360(G3) ,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
222 Dell PowerEdge: 2600, 2650, 6600, 6650 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 13, 51; FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES QLogic QLA200−E−SP7, 26 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
284 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Dell: 2342M6, 41, LPe1105−M1, 2, 17, 52 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES QME24622, 41, 53 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
285 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 2, 13, 52 ; FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES QLogic QLA200−E−SP2, 26, 41 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−34.0.2.EL
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
286 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 13, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
LangChao: NC3000, NC3500, NF500,
NF520
287 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP1050−E1, 2, 3, 52 FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−34.0.2.EL
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
288 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP982−E1, 2, 52 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.2.EL
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
Samsung SS140
305 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP1050−E1, 2, 52, 72 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
306 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E1, 2, 3, 52, LP982−E1, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES PCI−X 2, 52 FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−34.0.1.EL, U3+ AS/ES AX150
8848); v2.6.9−34.0.2.EL
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
307 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E1, 3, 52, LP982−E1, 52 FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
ML370(G3)9, ML370(G4)9 v2.6.9−34.0.2.EL
308 HPQ Proliant: DL380(G4)9, DL3859, DL5859, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 8, 35, FC−AL, EMC Y
ML370(G4)9 v2.6.9−34.EL, U3+ AS/ES PCI−X AE369A/FC1243 (QLA2462)2, 8, 36 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
309 IBM eServer: 325 (Model 8835), 326 (Model Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, IBM 24P0960 (QLA2340)2, 6, 16, 41 FC−AL, EMC Y
8848) v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
310 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 41 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
Fujitsu Siemens Primergy RX800 S2; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−34.0.2.EL
8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
311 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP6, 41 FC−AL, EMC Y
HPQ Proliant: DL1459, DL380(G4)9, DL3859, v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
ML370(G3)9, ML370(G4)9; v2.6.9−34.0.2.EL
Samsung SS140
312 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−42.EL, U4+ AS/ES QLogic: QLA200−E−SP2, 5, 26, FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; v2.6.9−42.0.2.EL QLA210−E−SP2, 5, 26 AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL380(G2)9, DL380(G3)9, DL3809,
DL580(G2)9, DL5809, ML350(G2)9,
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
313 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E1, 2, 3, 4, LP982−E1, 2, FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−42.EL, U4+ AS/ES 4; FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450 v2.6.9−42.0.2.EL AX150
QLogic QLA2340−E−SP2, 5, 6
314 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E1, 3, 4, LP982−E1, 4 FC−AL, EMC Y
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, v2.6.9−42.0.2.EL AX150
ML530(G3)9, ML5309, ML5709, ML7509
315 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI NEC N8190−120 (LP1050)1, 4, 13, 23 FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
316 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic: QLA2340−E−SP5, 6, FC−AL, EMC Y
DL380(G2)9, DL380(G3)9, DL3809, v2.6.9−42.EL, U4+ AS/ES QLE220−E−SP2, 45, 46 FC−SW CLARiiON
DL580(G2)9, DL5809, ML350(G2)9, v2.6.9−42.0.2.EL AX150
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
342 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Dell: 2342M5, 6, LPe1105−M1, 2, 4, 17, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES QME24622, 5, 53 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
343 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES QLogic QLA200−E−SP2, 5, 26 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
9
HPQ Proliant: BL40p, DL360(G3) ,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
344 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E1, 4, 13 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.2.EL AX150
LangChao: NC3000, NC3500, NF500,
NF520
345 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP1050−E1, 2, 3, 4 FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
12
IBM xSeries: x255, x336 (8837) , x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
346 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP982−E1, 2, 4 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
347 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex: LP1050−E1, 3, 4, LP982−E1, 4 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.2.EL AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL760 (G2)9, DL7609,
ML570(G2)9;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: SS370, SS3840
348 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 5, 8, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES AE369A/FC1243 (QLA2462)2, 5, 8 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
349 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−120 (LP1050)1, 4, 13, 23 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
140Rd−4 v2.6.9−42.0.2.EL AX150
350 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 4, 23, 27 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
351 Dell PowerEdge: 2600, 2650, 6600, 6650 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA200−E−SP5, 26 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
352 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA210−E−SP2, 5, 26 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
Samsung SS140
362 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E1, 2, 3, 4, LP982−E1, 2, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES PCI−X 4; FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−42.0.2.EL AX150
8848); QLogic QLA2340−E−SP2, 5, 6
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
363 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E1, 3, 4, LP982−E1, 4 FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−42.0.2.EL AX150
ML370(G3)9, ML370(G4)9
364 HPQ Proliant: DL380(G4)9, DL3859, DL5859, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 5, 8, FC−AL, EMC Y
ML370(G4)9 v2.6.9−42.EL, U4+ AS/ES PCI−X AE369A/FC1243 (QLA2462)2, 5, 8 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
365 IBM eServer: 325 (Model 8835), 326 (Model Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, IBM 24P0960 (QLA2340)2, 5, 6, 16 FC−AL, EMC Y
8848) v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
377 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−40.EL30, 31 32, 61, HS20 4GB Standard FC Exp Card CLARiiON
(26R0884)2, 20, 29 AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
378 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−47.EL30, 31 port: for NovaScale Blade Series CLARiiON
CFSN202−110040, 43, mini for NovaScale AX150
Blade 2021 CFSN202−210040, 43, mini
for NovaScale Blade 2021
CFSN202−210075, 76;
Bull: SBEFCM (SFF) Mezzanine HBA40,
43, SBEFCM4 (SFF) 4Gb Mezzanine
HBA39, 43
379 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Digital Henge Digital Henge: SBEFCM42, FC−SW EMC Y
v2.4.21−47.EL30, 31 39, 43, SBEFCM40, 43, SBFCM40, 43; CLARiiON
AX150
Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD2, 40, 43
380 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
8843); v2.4.21−47.EL30, 31 Card (39Y9186)2, 38, 67, 78 CLARiiON
AX150
IBM BladeCenter: LS20 (Model 8850), LS21
(Model 7971), LS41 (Model 7972)
381 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−47.EL30, 31 44, (48P7061)2, 6, 44 CLARiiON
AX150
IBM BladeCenter HS40 (Model 8839)
382 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) for FC−SW EMC Y
v2.4.21−47.EL30, 31 IBM eServer LS202, 6, 44, SFF Exp Card CLARiiON
(26K4841) for IBM eServer LS202, 6, 44 AX150
383 IBM BladeCenter: HS20 (Model 8843), LS20 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y
(Model 8850), LS21 (Model 7971), LS41 v2.4.21−47.EL30, 31 (26R0890)2, 22, 44, FC Exp Card CLARiiON
(Model 7972) (26K4841)2, 6, 44 AX150
384 IBM BladeCenter HS21 (Model 8853)69 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel FC−SW EMC Y66
v2.4.21−47.EL30, 31 Exp Card (39Y9186)2, 38, 67, 68 , HS20 CLARiiON
4GB SFF FC Exp Card (26R0890)2, 21, AX150
22, 44, HS20 FC Exp Card (13N2203)2, 6,
44, HS20 FC Exp Card (48P7061)2, 6, 44
393 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull SBEFCM (SFF) Mezzanine HBA2, 75, FC−SW EMC Y
v2.4.21−40.EL30, 31, U8 AS/ES 76 CLARiiON
v2.4.21−47.EL30, 31 AX150
394 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−40.EL30, 31, U8 AS/ES port for NovaScale Blade Series CLARiiON
v2.4.21−47.EL30, 31; CFSN202−110075 AX150
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES
v2.6.9−34.EL, U3+ AS/ES
v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL
395 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, 7, FC−SW EMC Y10, 11
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−22.EL, U2+ AS/ES (48P7061)2, 6, 7 CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
IBM BladeCenter HS40 (Model 8839) v2.6.9−22.0.2.EL
396 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES (26R0890)2, 21, 22, 58 , FC Exp Card CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES (26K4841)2, 6, 7 AX150
v2.6.9−22.0.2.EL
397 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES (26R0890)2, 22, FC Exp Card (13N2203) CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES for IBM eServer LS202, 6, 7, FC SFF Exp AX150
v2.6.9−22.0.2.EL Card (26K4841) for IBM eServer LS202,
6, 7
398 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y10, 11
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−22.EL, U2+ AS/ES 51, 61, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES (26R0884)2, 7, 20 AX150
IBM BladeCenter: HS40 (Model 8839), LS20 v2.6.9−22.0.2.EL
(Model 8850)
399 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES port: for NovaScale Blade Series CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES CFSN202−110040, 41, mini for NovaScale AX150
v2.6.9−34.0.2.EL Blade 2021 CFSN202−210040, 42;
Bull SBEFCM (SFF) Mezzanine: HBA2,
75, HBA40, 41;
28. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
29. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
30. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
31. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
32. Driver Version 7.3.3 Driver is integrated into the kernel.
33. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
34. Firmware Version 2.50a8
35. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
36. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. Driver Version 7.07.00
38. Driver Version 7.3.6 Driver is integrated into the kernel.
39. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
40. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com
41. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
42. Driver Version 8.01.−2−d4 Driver is integrated into the kernel.
43. Driver Version 7.07.04b6 Driver is integrated into the kernel.
44. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
45. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
46. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
47. Booting from the SAN with PowerPath is not supported.
48. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
49. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
50. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
51. Driver Version 8.0.16.17 Driver is integrated into the kernel.
52. Driver Version 8.0.16.18 Driver is integrated into the kernel.
53. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
54. Driver Version 7.3.2 Driver is integrated into the kernel.
55. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
56. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
57. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
58. Driver Version 8.01.00
59. dual core machine not support
60. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
61. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
62. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
63. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
64. Accepts PCI−X 1.0 and 2.0 HBAs.
65. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
66. PowerPath is not supported.
67. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
68. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
69. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
70. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
71. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
72. Firmware Version 1.91a1
73. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
74. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
75. BIOS 1.43
76. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
77. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
78. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
79. BIOS 1.70a3
80. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
81. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
82. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
83. Driver/BIOS are available at http://www.qlogic.com
84. BIOS 1.02
85. Driver Version 7.07.05
86. Driver Version 9.1.2.11
87. Driver Version 9.1.2.10
88. Driver Version 9.1.2.15 STORPort Miniport Driver
89. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
90. Driver Version 9.1.2.16 STORPort Miniport Driver
91. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
92. Firmware Version 2.50a4 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
93. Driver Version 8.01.16.17
94. Driver Version 8.0.16.18
95. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
96. Driver Version 7.01.01 Driver is integrated into the kernel.
97. Tested as an installable file system on a Linux cluster
Ibrix Fusion File system version 1.3 is supported with this configuration.
FusionFS Server Appliance Requirements:
CPU− x86, Xeon, 3+GHz, 2GB RAM
SMP Not Supported
NIC −Intel Pro 1000 Server adapter with 5.2.39 or BroadcomBCM5700
Please check E−Lab Navigator for the latest version of PowerPath supported on this configuration.
98. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file
names must be used.
99. Driver Version 7.1.14 Driver is integrated into the kernel.
100. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
101. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
102. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
103. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
104. Driver Version 7.1.14
105. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
106. Driver Version 7.03.00
107. Driver Version 7.03.00 QLogic driver obtained from http://www.qlogic.com
108. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
109. Firmware Version 2.50a8 Driver is integrated into the kernel.
110. Driver Version 8.0.16.6_x2
111. Driver Version 8.0.16.6_x2−2
18 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC Y3, 15
U6 AS/ES v2.4.21−37.EL, U6+ 381881−B2118, 43, Emulex−based BL25/30/35/45p Fibre Channel FC−SW CLARiiON
AS/ES v2.4.21−37.0.1.EL Mezzanine HBA − 394588−B218, 41, 42, 56 AX150
19 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0: PCI, Emulex: LP101−E6, 8, 23, 51 , LP1050−E8, 17, 51, LP982−E8, 51; FC−AL, EMC N3, 15
DL14528, DL38528, U6 AS/ES v2.4.21−37.EL, U6+ PCI−X FC−SW CLARiiON
DL58528 AS/ES v2.4.21−37.0.1.EL QLogic: QLA200−E−SP6, 9, QLA210−E−SP6, 9, 43, QLA2340−E−SP11, AX150
52
20 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0: PCI QLogic QLE220−E−SP6, 27, 57 FC−AL, EMC Y
U7 AS/ES v2.4.21−40.EL21, 32, Express, FC−SW CLARiiON
U8 AS/ES v2.4.21−47.EL21, 32 PCI−X AX150
21 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 PCI−X Emulex: LP1050−E6, 8, 16, 17 , LP982−E6, 8, 16; FC−AL, EMC Y3, 15
U1 AS/ES v2.6.9−11.EL13 FC−SW CLARiiON
QLogic QLA2340−E−SP6, 11, 12 AX150
22 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP101−E6, 8, 16, 23 , LP1050−E8, 16, 17, LP982−E8, 16; FC−AL, EMC N3, 15
DL14528, DL38528, U1 AS/ES v2.6.9−11.EL13 PCI−X FC−SW CLARiiON
DL58528 QLogic: QLA200−E−SP6, 9, 12, QLA2340−E−SP11, 12 AX150
36 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP1050−E6, 7, 8, 17, LP982−E6, 7, 8; FC−AL, EMC Y
(Model 8835), 326 U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
(Model 8848) AS/ES v2.6.9−34.0.1.EL, U3+ IBM 24P0960 (QLA2340)6, 10, 11, 14 AX150
AS/ES v2.6.9−34.0.2.EL
37 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: PCI, QLogic QLA2340−E−SP6, 10, 11 FC−AL, EMC Y
Primergy RX800 S2; U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
IBM eServer: 325 AS/ES v2.6.9−34.0.1.EL, U3+ AX150
(Model 8835), 326 AS/ES v2.6.9−34.0.2.EL
(Model 8848)
38 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: PCI, QLogic QLA2340−E−SP10, 11 FC−AL, EMC Y
Primergy RX800 S2; U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
HPQ Proliant: AS/ES v2.6.9−34.0.1.EL, U3+ AX150
DL14528, DL38528, AS/ES v2.6.9−34.0.2.EL
DL58528
39 IBM xSeries x3455 Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP10000ExDC−E1, 6, 8, 59, LP1050Ex−E1, 6, 8, 23; FC−AL, EMC Y
(7984) U4 AS/ES v2.6.9−42.EL, U4+ Express FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL IBM: 42C2069 (LPe11000)1, 6, 8, 55, 42C2071 (LPe11002)1, 6, 8, 24; AX150
QLogic: QLE2360−E−SP6, 35, 50, QLE2460−E−SP6, 35, 49
40 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y2, 3
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403621−B21)1, 4, 5 FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL AX150
(407234−B21),
(407235−B21)
41 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y45
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403621−B21)1, 5, 46 FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL AX150
(407234−B21),
(407235−B21)
42 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403619−B21)34, 35 FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL AX150
(407234−B21),
(407235−B21)
46 Dell PowerEdge 6950; Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP1050Ex−E1, 6, 8, 23, LPe111−E1, 4, 6, 8, LPe1150−E1, 6, 8, 24; FC−AL, EMC Y
IBM eServer 326m U4 AS/ES v2.6.9−42.EL, U4+ Express, FC−SW CLARiiON
(Model 7969) AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLE2360−E−SP6, 30, 31, 35 , QLE2460−E−SP6, 25, 35 AX150
47 IBM xSeries x3755 Red Hat RHEL [AMD−64] 4.0: PCI IBM: 24P0960 (QLA2340)6, 11, 14, 35 , 24P8053 (QLA2342)6, 11, 35; FC−AL, EMC Y
(8877) U4 AS/ES v2.6.9−42.EL, U4+ Express, FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLA2460−E−SP6, 35, 49, QLE2360−E−SP6, 35, 50, AX150
QLE2460−E−SP6, 35, 49
48 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: PCI−X Emulex: LP1050−E1, 6, 8, 17, LP982−E1, 6, 8; FC−AL, EMC Y
x4100, x4200 U4 AS/ES v2.6.9−42.EL, U4+ FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL QLogic QLA2340−E−SP6, 11, 35 AX150
49 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: PCI−X QLogic QLA2460−E−SP6, 25, 35 FC−AL, EMC Y
U4 AS/ES v2.6.9−42.EL, U4+ FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL AX150
50 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP101−E1, 6, 8, 23, LP1050−E1, 8, 17, LP982−E1, 8; FC−AL, EMC Y
DL14528, DL38528, U4 AS/ES v2.6.9−42.EL, U4+ PCI−X FC−SW CLARiiON
DL58528 AS/ES v2.6.9−42.0.2.EL QLogic: QLA200−E−SP6, 9, 35, QLA210−E−SP6, 9, 35, AX150
QLA2340−E−SP11, 35, QLE220−E−SP6, 27, 29, 44
51 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP1050−E1, 6, 8, 17, LP982−E1, 6, 8; FC−AL, EMC Y
(Model 8835), 326 U4 AS/ES v2.6.9−42.EL, U4+ PCI−X FC−SW CLARiiON
(Model 8848) AS/ES v2.6.9−42.0.2.EL IBM 24P0960 (QLA2340)6, 11, 14, 35 ; AX150
QLogic QLA2340−E−SP6, 11, 35
52 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0 PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)6, 33, 36, 38 , FC−SW EMC Y
LS20 (Model 8850) U7 AS/ES v2.4.21−40.EL21, 32 LP1005DC FC Exp Card6, 8, 33, 39 ; CLARiiON
AX150
IBM HS20 4GB SFF FC Exp Card: (26R0890)6, 43, 48, (26R0890)6, 48;
IBM HS20: 4GB Standard FC Exp Card (26R0884)6, 43, 47, FC Exp
Card (13N2203) for IBM eServer LS206, 11, 43, FC SFF Exp Card
(26K4841) for IBM eServer LS206, 11, 43
53 IBM BladeCenter: Red Hat RHEL [AMD−64] 3.0 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)6, 36, 37, 38 , FC−SW EMC Y
LS20 (Model 8850), U8 AS/ES v2.4.21−47.EL21, 32 HS20 4GB SFF FC Exp Card (26R0890)6, 40, 48, HS20 FC Exp Card CLARiiON
LS21 (Model 7971), (26K4841)6, 11, 40 AX150
LS41 (Model 7972)
54 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0 PCI−X IBM: Emulex LP1005DC FC Exp Card6, 8, 37, 39 , HS20 4GB Standard FC−SW EMC Y
LS20 (Model 8850) U8 AS/ES v2.4.21−47.EL21, 32 FC Exp Card (26R0884)6, 40, 47, HS20 FC Exp Card (13N2203) for IBM CLARiiON
eServer LS206, 11, 40, HS20 FC SFF Exp Card (26K4841) for IBM AX150
eServer LS206, 11, 40
55 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0: PCI−X IBM HS20 4GB SFF FC Exp Card: (26R0890)6, 43, 48, (26R0890)6, 48; FC−SW EMC N3, 15
LS20 (Model 8850) U6 AS/ES v2.4.21−37.EL, U6+ CLARiiON
AS/ES v2.4.21−37.0.1.EL IBM HS20 4GB Standard FC Exp Card (26R0884)6, 43, 47 AX150
56 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0: PCI−X IBM: Emulex LP1005DC FC Exp Card6, 8, 39, 56 , HS20 FC Exp Card FC−SW EMC Y3, 15
LS20 (Model 8850) U6 AS/ES v2.4.21−37.EL, U6+ (13N2203) for IBM eServer LS206, 11, 43, HS20 FC SFF Exp Card CLARiiON
AS/ES v2.4.21−37.0.1.EL (26K4841) for IBM eServer LS206, 11, 43 AX150
57 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: PCI−X IBM: Emulex LP1005DC FC Exp Card6, 8, 39, 51 , HS20 4GB SFF FC FC−SW EMC Y2, 3
LS20 (Model 8850) U2 AS/ES v2.6.9−22.EL, U2+ Exp Card (26R0890)6, 48, HS20 4GB Standard FC Exp Card CLARiiON
AS/ES v2.6.9−22.0.1.EL, U2+ (26R0884)6, 47, 52, HS20 FC Exp Card (13N2203) for IBM eServer AX150
AS/ES v2.6.9−22.0.2.EL LS206, 11, 52, HS20 FC SFF Exp Card (26K4841) for IBM eServer
LS206, 11, 52
58 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)6, 7, 36, 38 , FC−SW EMC Y
LS20 (Model 8850) U3 AS/ES v2.6.9−34.EL, U3+ LP1005DC FC Exp Card6, 7, 8, 39; CLARiiON
AS/ES v2.6.9−34.0.1.EL, U3+ AX150
AS/ES v2.6.9−34.0.2.EL IBM HS20 4GB: SFF FC Exp Card (26R0890)6, 10, 48, Standard FC Exp
Card (26R0884)6, 10, 47;
IBM HS20 FC: Exp Card (13N2203) for IBM eServer LS206, 10, 11, SFF
Exp Card (26K4841) for IBM eServer LS206, 10, 11
59 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)1, 6, 36, 38 , FC−SW EMC Y
LS20 (Model 8850) U4 AS/ES v2.6.9−42.EL, U4+ LP1005DC FC Exp Card1, 6, 8, 39; CLARiiON
AS/ES v2.6.9−42.0.2.EL AX150
IBM HS20 4GB: SFF FC Exp Card (26R0890)6, 35, 48, Standard FC Exp
Card (26R0884)6, 35, 47;
IBM HS20 FC Exp Card: (13N2203) for IBM eServer LS206, 11, 35,
(26K4841)6, 11, 35;
IBM HS20 FC SFF Exp Card (26K4841) for IBM eServer LS206, 11, 35
1. Driver Version 8.0.16.27 Driver is integrated into the kernel.
2. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
3. VxVM is not supported on servers booting from the array.
4. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
6. SNIA HBA API Supported.
7. Driver Version 8.0.16.18 Driver is integrated into the kernel.
8. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
9. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
11. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
14. This HBA is equivalent to the QLogic QLA2340.
15. Booting from the SAN with PowerPath is not supported.
16. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
17. Firmware Version 1.91a5
18. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X23 QLogic: QLA210−E−SP4, 20, 21, QLE220−E−SP4, FC−AL, EMC Y
(8865)24, 25, v2.4.21−40.EL18, 19 27, 62, 63 FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25
19 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 39, QME24624, 21, 46 FC−AL, EMC Y
v2.4.21−40.EL18, 19 Express, FC−SW CLARiiON
PCI−X AX150
20 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, Emulex: LP101−E1, 4, 10, 39 , LP1050−E1, 4, 31, 39 , FC−AL, EMC Y
Samsung: ES470, ES570, v2.4.21−40.EL18, 19 PCI−X LP982−E1, 4, 39; FC−SW CLARiiON
SS140 AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21
21 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 21 FC−AL, EMC Y
Samsung: ES570, SS140 v2.4.21−40.EL18, 19 PCI−X FC−SW CLARiiON
AX150
22 Samsung ES470 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 57 FC−AL, EMC Y
v2.4.21−40.EL18, 19 PCI−X FC−SW CLARiiON
AX150
23 Samsung: ES470, ES570, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, QLogic QLE220−E−SP4, 27, 62, 63 FC−AL, EMC Y
SS140 v2.4.21−40.EL18, 19 PCI−X FC−SW CLARiiON
AX150
42 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X23 QLogic: QLA210−E−SP4, 20, 56, QLE220−E−SP4, FC−AL, EMC Y
(8865)24, 25, v2.4.21−47.EL18, 19 62, 63 FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25
43 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 36, QME24624, 46, 56 FC−AL, EMC Y
v2.4.21−47.EL18, 19 Express, FC−SW CLARiiON
PCI−X AX150
44 HPQ Proliant: DL380(G5), Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, PCI Emulex: LPe111−E1, 4, 36, 37 , LPe1150−E1, 3, 4, 36; FC−AL, EMC Y
DL580(G4) v2.4.21−47.EL18, 19 Express, FC−SW CLARiiON
PCI−X HPQ: A8002A/FC2142SR (LPe1150)1, 4, 14, 36 , AX150
AE311A/FC1142SR (QLE2460)4, 5, 56,
AE312A/FC1242SR (QLE2462)4, 5, 56
45 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, Emulex: LP101−E1, 4, 10, 36 , LP1050−E1, 4, 31, 36 , FC−AL, EMC Y
Samsung: ES470, ES570, v2.4.21−47.EL18, 19 PCI−X LP982−E1, 4, 36; FC−SW CLARiiON
SS140 AX150
QLogic: QLA200−E−SP4, 20, 56, QLA210−E−SP4,
20, 56, QLA2340−E−SP4, 12, 56
46 Samsung: ES470, ES570, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, QLogic QLE220−E−SP4, 62, 63 FC−AL, EMC Y
SS140 v2.4.21−47.EL18, 19 PCI−X FC−SW CLARiiON
AX150
47 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI NEC N8190−120: (LP1050)1, 10, 11, 81 , (LP1050)1, FC−AL, EMC N17, 45
120Rd−1, 140Hd, v2.4.21−32.EL18, 73, U5+ AS/ES 10, 11, 82, 83 FC−SW CLARiiON
140Rc−4, 180Rd−4 v2.4.21−32.0.1.EL18, 73 AX150
48 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 47 ; FC−AL, EMC Y17, 45
1850, 2800, 2850; v2.4.21−32.EL18, 73, U5+ AS/ES Express QLogic QLE2360−E−SP4, 21, 40, 41 FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
49 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex: LP101−E1, 4, 10, 76 , LP1050−E1, 4, 31, 76 ; FC−AL, EMC Y17, 45
1850, 2800, 2850; v2.4.21−32.EL18, 73, U5+ AS/ES Express, FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 PCI−X QLogic QLA200−E−SP4, 20, 74, 75 AX150
LangChao: NC3000,
NC3500, NF500, NF520
50 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X Dell 2342M12, 80 FC−AL, EMC N17, 45
v2.4.21−32.EL18, 73, U5+ AS/ES FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 AX150
51 Dell PowerEdge: 2600, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 76 , LP1050−E1, 4, 31, 76 ; FC−AL, EMC Y17, 45
2650; v2.4.21−32.EL18, 73, U5+ AS/ES FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 QLogic QLA200−E−SP4, 20, 74, 75 AX150
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NF420;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS370,
SS3840, ZSS150,
ZSS230
60 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X Dell 2342M12, 21 FC−AL, EMC N17, 45
Unisys ES3105 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX150
61 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X Dell: LPe1105−M1, 3, 4, 47, QME24624, 21, 46 FC−AL, EMC N17, 45
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX150
67 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X23 Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 , FC−AL, EMC Y17, 45
(8865)24, 25, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP982−E1, 4, 47; FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25 QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21, QLA2340−E−SP4, 12, 21
68 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 47, QME24624, 21, 46 FC−AL, EMC N17, 45
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, FC−SW CLARiiON
PCI−X AX150
69 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 , FC−AL, EMC Y17, 45
Samsung: ES470, ES570, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X LP982−E1, 4, 47; FC−SW CLARiiON
SS140 AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21
70 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 21 FC−AL, EMC Y17, 45
Samsung: ES570, SS140 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX150
71 Samsung ES470 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 57 FC−AL, EMC Y17, 45
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX150
72 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP4, 30, 42 FC−AL, EMC Y
v2.4.21−40.EL18, 19, U8 AS/ES Express FC−SW CLARiiON
v2.4.21−47.EL18, 19 AX150
73 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP4, 30, 42 FC−AL, EMC Y
1900, 2850, 2900, 2950; v2.4.21−40.EL18, 19, U8 AS/ES Express, FC−SW CLARiiON
v2.4.21−47.EL18, 19 PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
74 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP4, 30, 42 FC−AL, EMC Y
2800 v2.4.21−40.EL18, 19, U8 AS/ES Express, FC−SW CLARiiON
v2.4.21−47.EL18, 19 PCI−X AX150
102 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Dell: 2342M12, 32, LPe1105−M1, 3, 4, 15, FC−AL, EMC Y16, 17
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QME24624, 32, 46 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
103 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
1950; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA200−E−SP4, 20, 32 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
104 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP1050−E1, 4, 15, 31 ; FC−AL, EMC Y16, 17
1950; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP4, 12, 32 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NF420;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150
105 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP982−E1, 4, 15 FC−AL, EMC Y16, 17
Digital Henge SH4500R4; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
IBM xSeries: x255, x336 U2+ AS/ES v2.6.9−22.0.2.EL AX150
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NF420;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150
106 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex: LP1050−E1, 15, 31, LP982−E1, 15; FC−AL, EMC Y16, 17
DL360(G4)28 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL HPQ: AB429A/FC1143 (QLA2460)4, 32, 33, AX150
AE369A/FC1243 (QLA2462)4, 32, 33
107 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X NEC N8190−120 (LP1050)1, 10, 11, 15 FC−AL, EMC Y16, 17
120Lh, 120Re−1, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
120Rf−1, 120Rg−2, U2+ AS/ES v2.6.9−22.0.2.EL AX150
120Rh−2, 140He,
140Rd−4
108 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 11, 14, 15 FC−AL, EMC Y16, 17
140He, 140Rd−4 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
109 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X QLogic QLA210−E−SP4, 20, 32 FC−AL, EMC Y16, 17
Digital Henge SH4500R4; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
HPQ Proliant U2+ AS/ES v2.6.9−22.0.2.EL AX150
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
110 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP12, 32 FC−AL, EMC Y16, 17
HPQ Proliant v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
DL360(G4)28; U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC2000,
NF420;
Lenovo SureServer: R630
6004, T630 6003
111 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X QLogic: QLA200−E−SP4, 20, 32, QLA210−E−SP4, FC−AL, EMC Y
RX300 S2, TX200 S2, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, 20, 32 FC−SW CLARiiON
TX300 S2 U2+ AS/ES v2.6.9−22.0.2.EL AX150
112 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X23 Emulex: LP1050−E1, 4, 15, 31 , LP982−E1, 4, 15; FC−AL, EMC Y16, 17
(8865)24, 25, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
x3950/x3950E/x460 U2+ AS/ES v2.6.9−22.0.2.EL QLogic QLA2340−E−SP4, 12, 32 AX150
(8872, 8874)24, 25
113 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 15, QME24624, 32, 46 FC−AL, EMC Y16, 17
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X AX150
114 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, Emulex LP1050−E1, 4, 15, 59 ; FC−AL, EMC Y
RX800 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X QLogic: QLA2340−E−SP12, 32, QLA2340−E−SP4, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL 12, 32 AX150
116 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, Emulex: LP1050−E1, 4, 15, 31 , LP982−E1, 4, 15; FC−AL, EMC Y16, 17
1850, 2800, 2850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL QLogic QLA2340−E−SP4, 12, 32 AX150
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
117 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)4, 32, 33, FC−AL, EMC Y16, 17
DL380(G4)28, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X AE369A/FC1243 (QLA2462)4, 32, 33 FC−SW CLARiiON
ML370(G4)28 U2+ AS/ES v2.6.9−22.0.2.EL AX150
118 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 4, 59; FC−AL, EMC Y
RX300 S2, TX200 S2, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP12 FC−SW CLARiiON
TX300 S2 U2+ AS/ES v2.6.9−22.0.2.EL, U3 AS/ES AX150
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL,
U3+ AS/ES v2.6.9−34.0.2.EL
119 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, Express QLogic QLE2360−E−SP32, 40, 41 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
120 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP101−E1, 10, 15, LP1050−E1, 15, 31, FC−AL, EMC Y16, 17
v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, Express LP982−E1, 15, LP982−E1, 4, 15; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
QLogic QLA2340−E−SP12, 32
121 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LPe111−E1, 4, 15, 37 , LPe1150−E1, 3, 4, 67; FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL QLogic: QLE2360−E−SP4, 32, 40, 41 , AX150
LangChao: NC3000, QLE2460−E−SP4, 5, 32
NC3500, NF520;
Samsung ZSS230
122 LangChao: NC3000, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP1050−E1, 4, 15, 31 ; FC−AL, EMC Y16, 17
NC3500, NF500, NF520; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP4, 12, 32 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Samsung ZSS230
123 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP982−E1, 4, 15 FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
124 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex: LP101−E1, 10, 15, LP1050−E1, 15, 31, FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, LP982−E1, 15; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC3000, QLogic QLA2340−E−SP12, 32
NC3500, NF500, NF520
125 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 4, 59 FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
126 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Fujitsu Siemens BX600−FC22Q4, 6, 12, 13 FC−AL, EMC Y
BX620 S3, BX630 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
(2−way), BX630 (4−way), U3+ AS/ES v2.6.9−34.0.2.EL AX150
BX630 (8−way)
127 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP101−E1, 2, 4, 10; FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL 20 AX150
Digital Henge Revo:
JS1400, JS2400
128 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 4, 31; FC−AL, EMC Y
2800, 2850 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express QLogic QLA2340−E−SP4, 6, 12 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
129 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 4, 10 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
130 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP982−E1, 2, 4 FC−AL, EMC Y
2800, 2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Samsung ZSS230
148 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI NEC: N8190−120 (LP1050)11, 31, 60, 61 , FC−AL, EMC Y
120Li, 120Rg−1, 120Ri−2, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, N8190−127 (LPe1150)3, 11, 60, 61 FC−SW CLARiiON
140Hf, 140Re−4 U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
149 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP12 FC−AL, EMC Y
RX220, RX600 S3, TX600 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
S3 U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
150 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP4, 6, 12 FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy:
RX220, RX600 S3, TX600
S3;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
151 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP6, 12 FC−AL, EMC Y
RX220, RX600 S3, TX600 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
S3; U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
HPQ Proliant
ML350(G4)28
154 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Dell: 2342M6, 12, LPe1105−M1, 2, 3, 4, QME24624, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, 6, 46 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
155 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 2, 4, 10; FC−AL, EMC Y
1950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, QLogic QLA200−E−SP4, 6, 20 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
156 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 2, 10 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520
157 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP1050−E1, 2, 4, 31; FC−AL, EMC Y
1950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, QLogic QLA2340−E−SP4, 6, 12 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
158 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP982−E1, 2, 4 FC−AL, EMC Y
Digital Henge INNO: v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
HR−4850, HR−6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
159 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex: LP1050−E1, 2, 31, LP982−E1, 2 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
HPQ Proliant
DL360(G4)28;
LangChao: NC3000,
NC3500, NF500, NF520
160 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y16, 17
(416653−B21), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, c−Class Bladesystem: (403621−B21)2, 69, 70, FC−SW CLARiiON
(416654−B21), U3+ AS/ES v2.6.9−34.0.2.EL (403621−B21)2, 69, 78 AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
171 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, PCI QLogic QLE220−E−SP4, 29, 30 FC−AL, EMC Y
2800 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
172 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, Emulex LP1050−E1, 2, 4, 59 FC−AL, EMC Y
RX800 S2 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
173 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, Emulex: LP101−E1, 2, 4, 10, LP1050−E1, 2, 31, FC−AL, EMC Y
DL380(G4)28, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X LP982−E1, 2; FC−SW CLARiiON
ML370(G4)28 U3+ AS/ES v2.6.9−34.0.2.EL AX150
HPQ: AB429A/FC1143 (QLA2460)4, 33, 34,
AE369A/FC1243 (QLA2462)4, 33, 35;
QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6,
20,
QLE220−E−SP4, 27, 29, 30
174 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, Emulex: LP1050−E1, 2, 4, 31, LP982−E1, 2, 4 FC−AL, EMC Y
1850, 2800, 2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
175 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP4, 6, 12 FC−AL, EMC Y
1850, 2800, 2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Fujitsu Siemens Primergy
RX800 S2;
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
193 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LP1050Ex−E1, 4, 10, 49 , LPe111−E1, 4, 37, FC−AL, EMC Y
2950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, 49, LPe1150−E1, 3, 4, 49; FC−SW CLARiiON
PCI−X AX150
Digital Henge Revo: QLogic: QLE2360−E−SP4, 40, 41, 48 ,
AS1500, AS1550, QLE2460−E−SP4, 5, 48
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
194 IBM xSeries: x3550 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI IBM: 24P0960 (QLA2340)4, 12, 48, 55 , 24P8053 FC−AL, EMC Y
(7978), x3650 (7979) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, (QLA2342)4, 12, 48; FC−SW CLARiiON
PCI−X AX150
QLogic: QLA2460−E−SP4, 48, 64,
QLE2360−E−SP4, 48, 65, QLE2460−E−SP4, 48, 64
195 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI NEC: N8190−120 (LP1050)11, 31, 49, 61 , FC−AL, EMC Y
120Li, 120Rg−1, 120Ri−2, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, N8190−127 (LPe1150)3, 11, 49, 61 FC−SW CLARiiON
140Hf, 140Re−4 PCI−X AX150
196 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP4, 30, 38 FC−AL, EMC Y
1900, 2850, 2900, 2950, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
6800, 6850; PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
197 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LP101−E1, 4, 10, 49 , LP1050−E1, 31, 49, FC−AL, EMC Y
JS1400, JS2400 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E1, 49; FC−SW CLARiiON
PCI−X 22 AX150
QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4,
20, 48, QLA2340−E−SP12, 48, QLE220−E−SP4, 27,
30, 38
214 HPQ Proliant: DL380(G5), Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI Emulex: LPe111−E1, 4, 37, 49 , LPe1150−E1, 3, 4, 49; FC−AL, EMC Y
DL580(G4) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X HPQ: A8002A/FC2142SR (LPe1150)1, 4, 14, 49 , AX150
AE311A/FC1142SR (QLE2460)4, 5, 48,
AE312A/FC1242SR (QLE2462)4, 5, 48;
QLogic: QLE2460−E−SP4, 5, 48, QLE2462−E−SP4,
5, 48
215 HPQ Proliant: DL380(G5), Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP4, 27, 30, 38 FC−AL, EMC Y
DL580(G3)28, DL580(G4) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX150
216 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP4, 30, 38 FC−AL, EMC Y
2800 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX150
217 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, Emulex: LP101−E1, 4, 10, 49 , LP1050−E1, 31, 49, FC−AL, EMC Y
DL380(G4)28, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X LP982−E1, 49; FC−SW CLARiiON
ML370(G4)28 AX150
HPQ: AB429A/FC1143 (QLA2460)4, 33, 48,
AE369A/FC1243 (QLA2462)4, 33, 48;
QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4,
20, 48,
QLA2340−E−SP12, 48, QLE220−E−SP4, 27,
30, 38
218 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, Emulex: LP1050−E1, 4, 31, 49 , LP982−E1, 4, 49; FC−AL, EMC Y
1850, 2800, 2850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP4, 12, 48 AX150
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
219 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843) v2.4.21−40.EL18, 19 (39Y9186)4, 39, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 21, HS20 FC Exp Card AX150
(26K4841)4, 12, 21
220 IBM BladeCenter HS21 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y52
(Model 8853)51 v2.4.21−40.EL18, 19 (39Y9186)4, 39, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 9, 21, HS20 FC Exp Card AX150
(13N2203)4, 12, 21, HS20 FC Exp Card
(48P7061)4, 12, 21
221 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 4, 39, 50 , FC−SW EMC Y
(Model: 8832−N1X), v2.4.21−40.EL18, 19 HS20 4GB Standard FC Exp Card (26R0884)4, 7, CLARiiON
8843) 21, HS20 FC Exp Card (13N2203)4, 12, 21, HS20 AX150
FC Exp Card (48P7061)4, 12, 21
222 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843) v2.4.21−47.EL18, 19 (39Y9186)4, 36, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 56, HS20 FC Exp Card AX150
(26K4841)4, 12, 56
223 IBM BladeCenter HS21 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y52
(Model 8853)51 v2.4.21−47.EL18, 19 (39Y9186)4, 36, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 9, 56, HS20 FC Exp Card AX150
(13N2203)4, 12, 56, HS20 FC Exp Card
(48P7061)4, 12, 56
34. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
35. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. Driver Version 7.3.6 Driver is integrated into the kernel.
37. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
38. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
39. Driver Version 7.3.3 Driver is integrated into the kernel.
40. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
41. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
42. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
43. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
44. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
45. Booting from the SAN with PowerPath is not supported.
46. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
47. Driver Version 7.3.2 Driver is integrated into the kernel.
48. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
49. Driver Version 8.0.16.27 Driver is integrated into the kernel.
50. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
51. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
52. PowerPath is not supported.
53. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
54. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
55. This HBA is equivalent to the QLogic QLA2340.
56. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
57. Driver Version 7.07.00
58. dual core machine not support
59. Firmware Version 1.91a1
60. Driver Version 8.0.16.18
61. BIOS 1.70a3
62. Driver Version 7.07.05
63. BIOS 1.02
64. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
65. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
66. Driver Version 8.01.00
67. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
68. BIOS 1.16
69. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
70. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
71. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
72. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
73. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file names
must be used.
74. Driver Version 7.01.01 Driver is integrated into the kernel.
75. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
76. Driver Version 7.1.14 Driver is integrated into the kernel.
77. Firmware Version 2.50a8
78. Firmware Version 2.50a8 Driver is integrated into the kernel.
79. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
80. Driver Version 7.04.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
81. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
82. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
83. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
39 HPQ Proliant DL580(G3)48 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E2, 19, 25, 36 , FC−AL, EMC Y21, 22
v2.6.5−7.2015, 6, 9, PCI−X LP1050−E19, 20, 25, LP982−E19, 25; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
QLogic: QLA200−E−SP2, 32, 50,
QLA210−E−SP2, 32, 50,
QLA2340−E−SP3, 32
40 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9 SP3: PCI Unisys: FCH732213−P64 FC−AL, EMC Y
ES7000/540 v2.6.5−7.244, v2.6.5−7.2445, 6, 9; (LP9002L−F2)18, 19, 40, FC−SW CLARiiON
FCH742313−P64 (LP9802)18, 19, 36, AX150
SuSE SLES [32−Bit] 9 SP3+: FCH752313−PCX (LP1050)18, 19, 36
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
41 Unisys ES7000/460 [32−Bit] SuSE SLES [32−Bit] 9 SP3: PCI, Unisys: FCH732213−P64 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2445, 6, 9; PCI−X (LP9002L−F2)18, 19, 40, FC−SW CLARiiON
FCH742313−P64 (LP9802)18, 19, 36, AX150
SuSE SLES [32−Bit] 9 SP3+: FCH752313−PCX (LP1050)18, 19, 36
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
1. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
2. VxVM is not supported on servers booting from the array.
3. SNIA HBA API Supported.
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
6. Firmware Version 1.91a5
7. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. PowerPath is not supported.
9. Driver Version 8.01.02−sles Driver is integrated into the kernel.
10. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.16
16. Driver Version 8.0.16.17 Driver is integrated into the kernel.
17. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
18. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. This HBA is equivalent to the QLogic QLA2340.
20. Firmware Version 2.50a8
21. BIOS 6.00a1
22. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
23. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
25. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
26. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Firmware Version 2.10a10
28. Firmware Version 2.50a6
29. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
30. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
31. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. BIOS 1.12
34. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
36. Booting from the SAN with PowerPath is not supported.
37. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
38. SGI's XFS filesystem is supported.
39. Driver Version 8.01.00
40. Driver Version 8.0.16.6_p3
41. Driver/BIOS are available at http://www.qlogic.com
42. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP1050Ex−E3, 6, 9, LPe1150−E3, 4, 6, FC−AL, EMC Y1, 2
RX220 v2.6.5−7.201, v2.6.5−7.20120, 21, Express, LPe1150−E3, 4, 6, 23 FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX150
9 Dell PowerEdge 1855; SuSE SLES [EM64T] 9 SP2+: PCI−X Dell 2342M7, 12 FC−AL, EMC Y1, 2
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.20120, 21, FC−SW CLARiiON
v2.6.5−7.202.7 AX150
10 Dell PowerEdge 1855 SuSE SLES [EM64T] 9 SP2+: PCI−X Dell: LPe1105−M3, 4, 6, 9, QME24626, 7, 35 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, FC−SW CLARiiON
v2.6.5−7.202.7 AX150
11 HPQ Proliant DL360(G4)14 SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 6, 11, 23 , LP1050−E3, 10, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
HPQ: AB429A/FC1143 (QLA2460)6, 7, 13,
AE369A/FC1243 (QLA2462)6, 7, 13;
QLogic: QLA200−E−SP6, 7, 22, QLA210−E−SP6, 7, 22,
QLA2340−E−SP7, 12
12 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, LP982−E3, 6, 9; FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.202.7 AX150
IBM xSeries: x336 (8837)39, QLogic QLA2340−E−SP6, 7, 12
x346 (8840)39, x3850/x366
(8863)36, 37;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
13 IBM xSeries: x3800/x260 SuSE SLES [EM64T] 9 SP2+: PCI−X38 Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
(8865)36, 37, v2.6.5−7.201, v2.6.5−7.20120, 21, LP982−E3, 6, 9; FC−SW CLARiiON
x3950/x3950E/x460 (8872, v2.6.5−7.202.7 AX150
8874)36, 37 QLogic QLA2340−E−SP6, 7, 12
14 Dell PowerEdge 1955 SuSE SLES [EM64T] 9 SP2+: PCI, PCI Dell: LPe1105−M3, 4, 6, 9, QME24626, 7, 35 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX150
15 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
2600, 2650, 2800, 2850; v2.6.5−7.201, v2.6.5−7.20120, 21, PCI−X LP982−E3, 6, 9; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
Samsung: ES470, ES570, QLogic QLA2340−E−SP6, 7, 12
SS140
16 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9 SP2+: PCI, HPQ: AB429A/FC1143 (QLA2460)6, 7, 13, FC−AL, EMC Y1, 2
ML370(G4)14 v2.6.5−7.201, v2.6.5−7.20120, 21, PCI−X AE369A/FC1243 (QLA2462)6, 7, 13 FC−SW CLARiiON
v2.6.5−7.202.7 AX150
17 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 6, 11, 23 , LP1050−E3, 10, 23, FC−AL, EMC Y1, 2
ML370(G4)14 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP6, 7, 22, QLA210−E−SP6, 7, 22,
QLA2340−E−SP7, 12
18 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI, Emulex LP1050−E3, 6, 46, 49 ; FC−AL, EMC Y
RX800 S2 v2.6.5−7.20120, 21, v2.6.5−7.202.7 PCI−X QLogic: QLA2340−E−SP6, 7, 12, QLA2340−E−SP7, 12 FC−SW CLARiiON
AX150
34 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP1050Ex−E3, 6, 11, 19 , LP1150−E3, 6, 19, 30 , FC−AL, EMC Y18
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, LPe111−E3, 6, 19, 24 ; FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 IBM: 24P0960 (QLA2340)6, 12, 17, 26 , 24P8053
(QLA2342)6, 12, 17, 39M5894 (QLA2460)6, 8, 17,
39M5895 (QLA2462)6, 8, 17;
QLogic: QLA2460−E−SP6, 8, 17, QLE2360−E−SP6,
15, 17, QLE2460−E−SP6, 8, 17
35 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI IBM: 24P0960 (QLA2340)6, 12, 25, 26 , 24P8053 FC−AL, EMC Y
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, (QLA2342)6, 12, 25, 39M5894 (QLA2460)6, 8, 17, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X 39M5895 (QLA2462)6, 8, 17; AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
QLogic: QLA2460−E−SP6, 8, 17, QLE2360−E−SP6,
15, 17
36 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP12, 17 FC−AL, EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX300 S3, TX600 S3; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
HPQ Proliant ML350(G4)14
37 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Fujitsu Siemens Primergy:
RX200 S3, RX220, RX600
S3, TX300 S3, TX600 S3;
IBM xSeries: x3550 (7978),
x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
38 Dell PowerEdge: 1850, 1900, SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE220−E−SP6, 28, 29 FC−AL, EMC Y
2850, 2900, 2950, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
39 Dell PowerEdge 1855; SuSE SLES [EM64T] 9: SP3 PCI−X Dell 2342M12, 17 FC−AL, EMC Y
Unisys ES3105 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
40 Dell PowerEdge 1855 SuSE SLES [EM64T] 9: SP3 PCI−X Dell: LPe1105−M3, 4, 6, 19, QME24626, 17, 35 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
41 IBM xSeries x3850/x366 SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP9802−E3, 6, 11, 19 FC−AL, EMC Y
(8863)36, 37 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
42 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 6, 11, 19 , LP1050−E3, 6, 10, 19 , FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ LP982−E3, 6, 19 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
IBM xSeries: x336 (8837)39, v2.6.5−7.276, SP3+ v2.6.5−7.282
x346 (8840)39, x3850/x366
(8863)36, 37;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
44 HPQ Proliant BL460c: SuSE SLES [EM64T] 9: SP3 PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y1, 2
(416653−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ c−Class Bladesystem (403621−B21)19, 24, 47 FC−SW CLARiiON
(416654−B21), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
(416655−B21), v2.6.5−7.276, SP3+ v2.6.5−7.282
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21), (416669−B21)
45 HPQ Proliant BL460c: SuSE SLES [EM64T] 9: SP3 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(416653−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Bladesystem (403619−B21)25, 45 FC−SW CLARiiON
(416654−B21), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
(416655−B21), v2.6.5−7.276, SP3+ v2.6.5−7.282
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21), (416669−B21)
46 Dell PowerEdge: 1950, 6800, SuSE SLES [EM64T] 9: SP3 PCI−X QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
6850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
Digital Henge SH4500R4; v2.6.5−7.276, SP3+ v2.6.5−7.282
IBM xSeries: x336 (8837)39,
x346 (8840)39, x3850/x366
(8863)36, 37;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
47 Dell PowerEdge 1955 SuSE SLES [EM64T] 9: SP3 PCI, PCI Dell: LPe1105−M3, 4, 6, 19, QME24626, 17, 35 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
48 HPQ Proliant DL380(G5) SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LP101−E3, 6, 11, LP1050−E3, 10, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: AB429A/FC1143 (QLA2460)6, 13, 17, AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)6, 13, 17;
QLogic: QLA200−E−SP6, 17, 22, QLA210−E−SP6, 17,
22, QLE220−E−SP6, 27, 28, 29
49 HPQ Proliant: DL380(G5), SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LPe111−E3, 6, 19, 24 , LPe1150−E3, 4, 6, 19; FC−AL, EMC Y
DL580(G4) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: A8002A/FC2142SR (LPe1150)3, 6, 19, 31 , AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE311A/FC1142SR (QLE2460)6, 8, 44,
AE312A/FC1242SR (QLE2462)6, 8, 17;
QLogic: QLE2460−E−SP6, 8, 17, QLE2462−E−SP6, 8,
17
50 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLA2340−E−SP12, 17 FC−AL, EMC Y
TX200 S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
HPQ Proliant DL380(G5) v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
51 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
TX200 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
52 Dell PowerEdge: 1800, 2800 SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLE220−E−SP6, 28, 29 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
53 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, Emulex LP1050−E3, 6, 19, 49 FC−AL, EMC Y
RX800 S2 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
54 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 6, 11, 19 , LP1050−E3, 6, 10, 19 , FC−AL, EMC Y
2600, 2650, 2800, 2850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X LP982−E3, 6, 19 FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
Samsung: ES470, ES570, v2.6.5−7.276, SP3+ v2.6.5−7.282
SS140
55 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 6, 11, LP1050−E3, 10, LP982−E3; FC−AL, EMC Y
ML370(G4)14 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ HPQ: AB429A/FC1143 (QLA2460)6, 13, 17, AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)6, 13, 17;
QLogic: QLA200−E−SP6, 17, 22, QLA210−E−SP6, 17,
22, QLE220−E−SP6, 27, 28, 29
Sun Solaris
Sun Solaris
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex: LP10000−E4, 12, 13, 23, 24, 25, 26, 36, 37, 38, 39, 40, 41 , FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris LP9002−E (LP9002L−E)4, 12, 13, 23, 24, 25, 26, 36, 39, 41, 42, 43 , FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 109, 10, 11 LP9802−E4, 12, 13, 23, 24, 25, 26, 36, 37, 38, 39, 40, 41 ; AX150
QLogic QLA2340−E−SP4, 6, 12, 13, 30, 31, 32, 33, 34, 35 ;
Sun: SG−XPCI1FC−EM2 (LP10000)12, 23, 24, 25, 26 ,
SG−XPCI1FC−QL2 (QLA2340)2, 4, 6, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21,
22, X6767A (SG−XPCI1FC−QF2)4, 6, 12, 48
2 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex LP8000−EMC4, 36, 39, 44, 45, 46, 47 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 1010, 11 AX150
3 Sun Sun Fire: 4800, 6800 Sun PCI Emulex LP9002C−E4, 12, 23, 25, 36, 38, 39, 42, 46, 47 FC−AL, EMC N
Solaris FC−SW CLARiiON
1010, 11 AX150
4 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP1, 3, 5, 6, 13, 28, 30, 31, 32, 33, 35, 49 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 8 FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 AX150
5 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−QL2 (QLA2340)1, 2, 3, 4, 5, 6 , X6767A FC−AL, EMC N
Solaris 8 (SG−XPCI1FC−QF2)1, 3, 4, 5, 6, 12, 48 FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, AX150
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R8, 250, 420R8, 450
6 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun SG−XPCI1FC−EM2 (LP10000)1, 3, 5, 12, 13, 24, 25, 26, 28 FC−AL, EMC N
Solaris FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, 829 AX150
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R8, 250, 420R8, 450
Sun Solaris
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
7 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP1, 3, 5, 6, 13, 28, 30, 31, 32, 33, 35, 49 ; FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 9 Sun: SG−XPCI1FC−EM2 (LP10000)1, 3, 5, 12, 13, 24, 25, 26, 27, 28 , FC−SW CLARiiON
V250, V480, V490, V880, V890 SG−XPCI1FC−QL2 (QLA2340)1, 2, 3, 4, 5, 6 , X6767A AX150
(SG−XPCI1FC−QF2)1, 3, 4, 5, 6, 12, 27, 48
8 Sun Sun Fire V440 Sun PCI QLogic QLA2340−E−SP1, 3, 5, 6, 13, 28, 30, 31, 32, 33, 35, 49 FC−AL, EMC N
Solaris 97 FC−SW CLARiiON
AX150
9 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−EM2 (LP10000)1, 3, 5, 12, 13, 24, 25, 26, 27, 28 , FC−AL, EMC N
Solaris 97 SG−XPCI1FC−QL2 (QLA2340)1, 2, 3, 4, 5, 6 , X6767A FC−SW CLARiiON
Sun Sun Fire: V210, V440; (SG−XPCI1FC−QF2)1, 3, 4, 5, 6, 12, 27, 48 AX150
Sun Ultra: 220R8, 250, 420R8, 450
1. Driver Version SAN 4.4.10
2. FCode Value 1.14.09
3. Driver Version SAN 4.4.9
4. SNIA HBA API Supported.
5. Driver Version SAN 4.4.11
6. FCode Value 1.14.15
7. EMC required Sun patches for Solaris 9:
112233−12 SunOS 5.9: kernel patch
117171−17 SunOS 5.9: kernel patch
118558−34 SunOS 5.9: kernel patch
112834−06 SunOS 5.9: patch SCSI
113277−47 SunOS 5.9: sd and ssd patch
8. 64−bit HBAs will not fit into the 32−bit slot due to a physical obstruction.
9. STMS (MPxIO) is supported with the following patch installed: 119715−09
10. If setting the boot disk from SAN with Solaris 10, its Target/LUN must be defined in the /kernel/drv/sd.conf file.
11. EMC requres Sun patches for Solaris 10:
118822−30 SunOS 5.10: Kernel patch
118833−24 SunOS 5.10: Kernel patch
119130−26 SunOS 5.10: Sun Fibre Channel Device Drivers (only necessary for Leadville Stack driver)
120222−11 SunOS 5.10: Emulex−Sun LightPulse fibre channel adapter driver (only requred for Emulex HBAs)
12. STMS is Sun's Multipathing Software and not an EMC Software product. Please refer to the required release note "SUN
StorEdge Traffic Manager for CLARiiON Release Notes", P/N 300−002−978, which can be found on EMC's Powerlink website in
Support −> Document Library −> Host Connectivity for the complete Installation information.
13. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
Driver version SAN 4.3 or older is not supported for MPxIO on EMC Symmetrix storage. MPxIO is not supported on EMC
CLARiiON storage with Solaris 8.
14. Driver Version 4.4.4
15. Driver Version SAN 4.4.2
16. Driver Version SAN 4.4.8
17. Driver Version SAN 4.4.7a
18. Driver Version SAN 4.4.6
19. Driver Version SAN 4.4.4
20. Driver Version SAN 4.4.3
21. Driver Version SAN 4.4.1
22. Driver Version 4.4.3
23. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing
required patch 120222−04. These packages are available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
24. FCode Value 1.50a9
25. FCode Value 1.50a4
26. FCode Value 1.50a8
27. Sun StorEdge Traffic Manager Software (Sun's Native Multipathing Software) is supported on CLARiiON with SAN 4.4.7a and
above.
28. For servers running Solaris 8 or 9 with the Sun SAN driver, the following applies:
Must add "set fcp:ssfcp_enable_auto_configuration=1" (do not include quote marks) in /etc/system to fix the following problems:
1. VxVM − rootdg can not be imported during boot
2. SVM − Volume Manager can not be started after system boot
3. PowerPath 4.x − error message "All paths to (array type) (array name) vol(volume number) are dead"
29. SDS support on Solaris 8 requires minimum SDS version 4.2.1 with patch 108693−16 or later version.
30. Driver Version 4.17
31. FCode Value 2.00.09
32. Driver Version 4.22
33. FCode Value 1.14.13
34. Driver Version S10 Update 1 (01/06)
35. FCode Value 2.00.06
36. Driver Version 6.02f
37. Firmware Version 1.91a1
38. Driver Version SAN in Solaris 10 U1 (01/06)
39. Driver Version 6.02hx2
40. Firmware Version 1.91a5
41. Driver Version 6.10g
42. Firmware Version 3.92a3
43. Firmware Version 3.93a0
44. The LP8000−EMC HBA has a permanent GBIC, and does not have copper cable support.
45. Firmware Version 3.92a2
46. FCode Value 1.41a4
47. Driver Version 6.02e
48. FCode Value 1.14.11
49. Driver Version 4.15.03
54 Dell PowerEdge: 1850, 1950, 2800, VMware ESX Server: v3.0.12, 3, 6, PCI QLogic QLE2460−E−SP12, 32, 33 FC−AL, EMC Y
2850, 6800, 6850 8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, Express FC−SW CLARiiON
31 AX150
55 HPQ Proliant DL360(G4)21 VMware ESX Server: v3.0.12, 3, 6, PCI−X HPQ AB429A/FC1143 (QLA2460)12, 33, 46 FC−AL, EMC Y9, 16
8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, FC−SW CLARiiON
31 AX150
56 HPQ Proliant DL380(G5) VMware ESX Server: v3.0.12, 3, 6, PCI, PCI HPQ AB429A/FC1143 (QLA2460)12, 33, 46 FC−AL, EMC Y9, 16
8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, Express, FC−SW CLARiiON
31 PCI−X AX150
57 HPQ Proliant: DL380(G4)21, VMware ESX Server: v3.0.12, 3, 6, PCI, HPQ AB429A/FC1143 (QLA2460)12, 33, 46 FC−AL, EMC Y9, 16
DL38521, DL58521, ML370(G4)21 8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, PCI−X FC−SW CLARiiON
31 AX150
58 Dell PowerEdge: 2900, 2950; VMware ESX Server: v3.02, 3, 6, PCI Emulex LPe1150−E10, 12, 28, 29 FC−AL, EMC Y9, 16
30, 31, v3.02, 3, 6, 8, 30, 31 Express, FC−SW CLARiiON
Fujitsu Siemens Primergy RX600 S3 PCI−X AX150
59 Dell PowerEdge 1955 VMware ESX Server: v3.02, 3, 6, PCI, PCI Dell 2342M20, 24 FC−AL, EMC Y9, 16
30, 31, v3.02, 3, 6, 8, 30, 31 , v3.03, 6, Express, FC−SW CLARiiON
30, 31, v3.03, 6, 8, 30, 31 PCI−X AX150
60 HPQ Proliant DL380(G3)21 VMware ESX Server: v3.03, 6, 30, PCI Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38; FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
QLogic QLA2340−E−SP20, 39 AX150
61 Fujitsu Siemens Primergy BX66057 VMware ESX Server: v3.03, 6, 30, PCI Fujitsu Siemens BX600−FC22Q12, 20, 24, 58 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
62 Dell PowerEdge: 1950, 6850; VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 11, 12, 34 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
Fujitsu Siemens Primergy RX300 S3 AX150
63 Fujitsu Siemens Primergy RX300 S3 VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 12, 34, 37 ; FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express QLogic QLA2340−E−SP20 FC−SW CLARiiON
AX150
64 Dell PowerEdge 1950 VMware ESX Server: v3.03, 6, 30, PCI Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38; FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
QLogic QLE2360−E−SP12, 20, 36 AX150
65 Dell PowerEdge 1950; VMware ESX Server: v3.03, 6, 30, PCI QLogic QLA2340−E−SP20, 39 FC−AL, EMC Y9, 16
Fujitsu Siemens Primergy RX300 S3 31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
AX150
66 Dell PowerEdge 6850 VMware ESX Server: v3.03, 6, 30, PCI QLogic QLE2360−E−SP12, 20 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
AX150
67 Dell PowerEdge 6850 VMware ESX Server: v3.03, 6, 30, PCI Dell 2362M20, 48, 49 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
68 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 11, 12, 34 FC−AL, EMC Y9, 16
2950, 6850; 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
Fujitsu Siemens Primergy TX300 S3;
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)43
69 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 12, 34, 37 FC−AL, EMC Y9, 16
IBM eServer 326m (Model 7969) 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
127 HPQ Proliant BL460c: (416653−B21), VMware ESX Server v3.02, 3, 6, 8, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−SW EMC N
(416654−B21), (416655−B21), 30 Bladesystem (403619−B21)33, 56 CLARiiON
(416656−B21), (432636−B21); AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
128 Dell PowerEdge 6850 VMware ESX Server: v2.5.22, 3, 5, PCI QLogic QLE2360−E−SP12, 20, 44 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 Express CLARiiON
AX150
146 IBM BladeCenter HS20 (Model 8843) VMware ESX Server: v2.5.22, 3, 5, PCI−X IBM HS20 FC Exp Card (26K4841)12, 20, 24, 47 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 , v3.03, 6, 30, 31 , v3.03, 6, AX150
8, 30, 31
147 Dell PowerEdge: 1550, 255022, VMware ESX Server: v2.5.32, 3, 5, PCI Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
645023; 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
HPQ Proliant: DL360(G2)21,
DL36021, DL380(G3)21, DL58021;
IBM xSeries: x330, x335;
NEC Express 5800: 120Rf−2, 140Hd,
140Rc−4, 180Rc−4, 180Rd−4
148 NEC Express 5800: 120Rf−2, 140Hd, VMware ESX Server: v2.5.32, 3, 5, PCI NEC N8190−120 (LP1050)10, 11, 13, 17 FC−SW EMC N9
140Rc−4, 180Rd−4 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
149 NEC Express 5800 110Rg−1 VMware ESX Server: v2.5.32, 3, 5, PCI NEC N8190−120 (LP1050)10, 11, 13, 17 FC−SW EMC N9
6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
150 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server: v2.5.32, 3, 5, PCI−X Emulex LP1050−E10, 12, 13, 37 FC−SW EMC N9
6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
151 HPQ Proliant DL360(G4)21 VMware ESX Server: v2.5.32, 3, 5, PCI−X Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
6) For source LUNs configured as RDM volumes, the replica can be presented to the same ESX server but to a different Virtual Machine unless the guest OS is qualified to allow same
host access.
7) RDM volumes cannot be created when the ESX server is booting from SAN. VMFS volumes can be created when the ESX server is booting from SAN. If ESX server is not booting
from SAN, Virtual Machines can be configured using either VMFS or RDM volumes.
8) Ensure the snapshot is activated or clone fractured before presenting them to an ESX server.
9) When replicating OS images, you will only have a crash consistent copy if the Virtual Machines are not shutdown during the replication process.
10) Please note that replicating a suspended Virtual Machine will result in a crash consistent copy.
11) Admsnap, Admhost utilities must be installed only on Virtual Machines. With admsnap or admhost installed on the Virtual Machine, most of the commands issued on VMFS volumes
will fail, since VMFS volumes do not support scsi pass−through commands to talk to the CLARiiON. Use Navisphere Manager or Navisphere CLI instead. The only commands that will
work with VMFS volumes are admsnap flush and admhost flush. Admsnap is not supported under Netware Virtual Machines with either RDM or VMFS volumes.
5. Supported with VMFS and VMFS−2.
6. PowerPath is not supported on VMWare ESX. The VMWare ESX native failover functionality is supported.
7. While using an AX100−series storage system managed using Navisphere Express with VMware ESX Server, Snapshots cannot be assigned to the ESX server.
8. Replication of both VMFS and Raw Device Mapping (RDM) volumes is supported using Symmetrix replication software (SRDF and TimeFinder). Please refer to the solution guide,
'VMware ESX Server Using EMC Symmetrix Storage Systems' for details.
Replicas of application data volumes of physical (native) servers created using Symmetrix replication software can be presented to a VMware ESX Server. Note:
1) Replication of Operating System volumes and application volumes from a virtual to physical environment using Symmetrix replication software is not supported at this time.
2) Replication of Operating System volumes, application volumes and application data volumes from a virtual to virtual environment using Symmetrix replication software is supported.
9. Virtual machines running on VMWare ESX are supported booting from the array.
10. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
12. SNIA HBA API Supported.
13. Driver Version 2.01g This driver is included in the VMware ESX kernel.
14. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
15. BIOS 1.70a3
16. VMWare ESX Server itself is supported booting from external array.
17. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
18. Firmware Version 1.91a5
19. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Driver Version 7.04.00 This driver is included in the VMware ESX kernel.
21. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
22. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
23. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
24. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
26. Accepts PCI−X 1.0 and 2.0 HBAs.
27. Driver Version 7.04.00 Requires BIOS 1.45 (HP BL30p specific) available from QLogic at http://www.qlogic.com This driver is included in the VMware ESX kernel.
28. Firmware Version 2.50a6
29. Driver Version 7.3.2 This driver is included in the VMware ESX kernel.
30. Supported with VMFS−3.
31. Beginning with ESX Server v2.5.0 Navisphere components are supported as follows:
Navi Agent and Server Utility at the console level only;
Array Initialization Utility and CLI at both the console and VM levels;
Browser interface to Navi Manager at the VM level only.
32. BIOS 1.08
33. Driver Version 7.07.00 This driver is included in the VMware ESX kernel.
34. Driver Version 7.1.14 This driver is included in the VMware ESX kernel.
35. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
36. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
37. Firmware Version 1.91a1
38. FCode Value 1.70a3
39. Requires BIOS 1.47 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
40. BIOS 1.70a3 This driver is included in the VMware ESX kernel. Available in the EMC−approved section of the Emulex website. http://www.emulex.com
41. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. This HBA is equivalent to the QLogic QLA2340.
43. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
44. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
45. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
46. BIOS 1.17
47. Firmware Version 3.01.18
48. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
49. BIOS 1.06 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
50. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
51. This driver is included in the VMware ESX kernel.
52. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
53. Driver Version 7.07.04 This driver is included in the VMware ESX kernel.
54. BIOS 1.47
55. BIOS 1.12
56. BIOS 1.16
57. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
58. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
59. BIOS 6.00a1
60. Firmware Version 2.50a8
61. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
62. VxVM is not supported on servers booting from the array.
63. Only supported in a boot from SAN configuration.
Cluster Software
Microsoft Windows 2000
EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.
Novell Netware
Novell Netware
Operating Luns/Storage Port
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Storage Array
1 Novell Netware QLogic QLA2340−E−SP QLogic SANBox 15 15 256 128 Y EMC CLARiiON AX1501, 2,
6.5 SP3 SB1404−10AJ−E 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
2 Novell Netware QLogic: QLA200−E−SP, QLogic SANBox 15 15 256 128 Y EMC CLARiiON AX1501, 2,
6.5 SP3 QLA2340−E−SP SB3050−08A−E 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
3 Novell Netware QLogic: QLA200−E−SP, EMC Connectrix: 15 15 256 128 Y EMC CLARiiON AX1501, 2,
6.5 SP3 QLA2340−E−SP, QLE2360−E−SP 3250−VL2E15, DS−8B2−0DL; 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13
McDATA ES−430014
1. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
2. No MirrorView or SnapView used on boot LUNs.
3. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
4. Novell Storage Services supported.
5. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
6. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After Abend".
When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
7. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
8. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any found in
previous boot documentation.
9. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
10. Remote boot not supported with PERC controllers enabled in system BIOS.
11. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
12. Edit config.sys with the following: Files=100, Buffers=99
13. Supports eight (8) hosts per array.
14. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
15. This switch is offered by Dell as the Brocade VL2 LC.
Sun Solaris
Sun Solaris
Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Sun QLogic QLA2340−E−SP; EMC Connectrix: 3250−VL2E3, 4 15 256 128 Y EMC
Solaris: 10, Sun: SG−XPCI1FC−QL2 DS−220B−FF−D1, DS−4400M, CLARiiON
8, 9 (QLA2340), X6767A DS−4700M, DS−8B2−0DL; AX150
(SG−XPCI1FC−QF2)
McDATA: ES−43002, ES−4400, ES−4700
2 Sun Sun SG−XPCI1FC−EM2 EMC Connectrix: 3250−VL2E3, 4 15 256 128 Y EMC
Solaris: 8, (LP10000) DS−220B−FF−D1, DS−4400M, CLARiiON
9 DS−4700M, DS−8B2−0DL; AX150
McDATA: ES−43002, ES−4400, ES−4700
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.
Switches, Routers, Network Interface Cards (NICs), and iSCSI Host Bus Adapters (HBAs)
1. Support is provided for industry standard switches, routers and NICs (Network Interface Cards).
2. Supports up to 4 HBAs or 2 (dual SP) / 1 (single SP) NICs per server connecting to one storage system.
3. A single server can not use HBAs and NICs to connect to the same storage system.
4. Servers can not use a combination of HBAs and NICs to connect to different storage systems.
5. Separate servers, some with HBAs and some with NICs, can connect to the same storage system.
6. A single server cannot use a combination of Fibre Channel HBAs and NICs or iSCSI HBAs to attach to a Fibre storage system and an iSCSI storage system at the same time.
7. A server can be connected to a maximum of 4 CLARiiON storage systems.
8. An initiator can be connected to a maximum of 8 array ports (4 dual SP arrays) or 4 array ports (4 single SP arrays),but no more than 4 storage systems.
9. When a switch or router is present (1Gb), a 10/100 NIC can be used since the connection to the storage system is through the switch or router.
Considerations
1. The AX100i and AX100SCi has one front end iSCSI port per storage processor.
2. Currently it is not possible to boot a Windows system using an iSCSI disk volume provided by the Microsoft iSCSI Initiator. The only currently supported method for booting a
Windows system using an iSCSI disk volume is via a supported HBA.
3. When using multiple (NICs) in the same server: up to 2 NICs per host are supported to one AX100i array. If multiple NICs are installed, it is recommended that each be on a
different subnet. If multiple NICs are on the same subnet, the MS "Advanced" configuration setup must be utilized in order to take advantage of the additional NICs. If the
"Advanced" configuration setup in the MS initiator is not used, additional NICs would be used typically only in a failover situation.
4. When (HBAs) and NICs can not be present in the same host.
5. When using the Microsoft iSCSI Initiator all NICs in the same host will use the same iSCSI name. The name will identify the host and the NICs will not be identifiable.
6. When using Qlogic iSCSI adapters each HBA will have unique iSCSI names. The name will identify the individual HBA in the host.
7. Dynamic disks are not supported on an iSCSI session using the Microsoft iSCSI initiator.
8. EMC supports up to 2 nodes with iSCSI Windows server 2003 Cluster environments with the with the MS Initiator v 1.05. or later.
1. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
2. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
3. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
4. Routed networks (layer 3) require iSCSI digest to be enabled.
5. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
6. Microsoft Dynamic Disks are not supported.
7. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
8. Powerpath iSCSI 1.1 is not supported with Windows 2000 operating systems.
9. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
10. The following NICs are not supported: 3COM−3C996B
11. Any Microsoft supported server/NIC for the listed operating system revision is supported.
12. BIOS 1.08
13. Driver Version 2.1.3.3
14. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
15. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
16. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
17. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
18. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
19. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
20. Servers booting from external storage with QLA4010 iSCSI boards require Microsoft iSCSI Initiator 2.0 or 2.02 service to be installed. Note that HBA IQN must be altered prior to
Windows installation. Refer to EMC Host Connectivity Guide for information on changing IQN and setting up boot for servers requiring MS iSCSI Initiator service.
21. Firmware Version 2.0.0.38
22. Driver Version 2.1.0.3
23. Firmware Version 3.0.0.16
24. BIOS 1.11
25. Driver Version 2.1.1.0
26. Firmware Version 2.00.00.07
27. BIOS 1.04
6 MiracleLinux MLSE QLogic QLA4010−E−SP9, 10, 11, 12, 13 , QLogic QLA4010C−E−SP10, 12, 13, 18, 19 LAN Only4 EMC N
[32−Bit] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
2. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
3. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
4. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
5. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
6. Driver Version 5.00.04 Driver is integrated into the kernel.
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 3.00.00.16
14. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
18. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
5 MiracleLinux MLSE QLogic QLA4010−E−SP9, 10, 11, 13, 14 , QLogic QLA4010C−E−SP10, 13, 14, 17, 18 LAN Only3 EMC N
[AMD64] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
2. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
5. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
6. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Driver Version 5.00.04 Driver is integrated into the kernel.
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
6 MiracleLinux MLSE QLogic QLA4010−E−SP8, 9, 11, 13, 14 , QLogic QLA4010C−E−SP9, 13, 14, 17, 18 LAN Only2 EMC N
[EM64T] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
5. Driver Version 5.00.04 Driver is integrated into the kernel.
6. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
10. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 3.00.00.16
14. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
6 Red Flag DC Server QLogic QLA4010−E−SP1, 4, 5, 7, 17 , QLogic QLA4010C−E−SP1, 2, 4, 5, 6 LAN Only3 EMC N
[32−Bit] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
2. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Firmware Version 3.00.00.16
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
8. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
13. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
14. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
5 Red Flag DC Server QLogic QLA4010−E−SP4, 5, 8, 9, 16 , QLogic QLA4010C−E−SP5, 7, 8, 9, 10 LAN Only6 EMC N
[AMD64] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
8. Firmware Version 3.00.00.16
9. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
13. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
14. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP3, 15, 18, 24 , QLogic LAN Only EMC N See7, 8
QLA4010C−E−SP15, 18, 24 CLARiiON
AX100i
5 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10023, Generic NIC GbE22, 23 LAN Only EMC N See7, 8
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX100i
6 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP3, 4, 15, 18, 21 , QLogic LAN Only7 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP4, 15, 17, 18, 20 CLARiiON
AX100i
7 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)1, 3, 12, 25 CLARiiON
AX100i
8 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP1, 2, 3, 4, 5 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX100i
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10026, Generic NIC GbE26 LAN Only EMC N See7, 8
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX100i
10 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)3, 10, 11, 12 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 11, QLogic QLA4050C−E−SP2, 3, 4, 5, 11 AX100i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP3, 4, 11, 15, 18 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP4, 15, 16, 17, 18 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/1009, Generic NIC GbE9 LAN Only EMC N See7, 8
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP2, 3, 4, 5, 14 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP2, 3, 4, 5, 13 CLARiiON
AX100i
14 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)3, 6, 10, 12, 19 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
6,QLogic QLA4050C−E−SP2, 3, 4, 5, 6 AX100i
15 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP3, 4, 6, 15, 18 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP4, 6, 15, 17, 18 CLARiiON
AX100i
1. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
4. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
10. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
14. Driver Version 5.00.04 Driver is integrated into the kernel.
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Firmware Version 3.00.00.16
19. Firmware Version 2.00.00.38
20. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
21. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. The following NICs are not supported: 3COM−3C996B
23. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
24. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
27. Driver Version 3.22
1. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. Firmware Version 3.00.00.16
8. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
14. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
15. The following NICs are not supported: 3COM−3C996B
16. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
24. Driver Version 3.22
25. Driver Version 5.00.07
26. Firmware Version 2.00.00.38
27. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
28. Driver Version 5.00.04 Driver is integrated into the kernel.
4 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP1, 4, 13, 15 , QLogic LAN Only EMC N See10, 11
QLA4010C−E−SP1, 13, 15 CLARiiON
AX100i
5 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10020, Generic NIC GbE20, 21 LAN Only EMC N See10, 11
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX100i
6 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 13, 15, 18 , QLogic LAN Only10 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 13, 14, 15, 16 CLARiiON
AX100i
7 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)4, 8, 22, 23 CLARiiON
AX100i
8 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP2, 3, 4, 5, 22 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP2, 3, 4, 5, 22 CLARiiON
AX100i
Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10024, Generic NIC GbE24 LAN Only EMC N See10, 11
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX100i
10 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)4, 6, 7, 8, QLogic QLA4050−E−SP2, 3, 4, 5, 7 , CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA4050C−E−SP2, 3, 4, 5, 7 AX100i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP4, 5, 7, 13, 15 , QLogic LAN Only10 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 13, 15, 16, 17 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10012, Generic NIC GbE12 LAN Only EMC N See10, 11
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP2, 3, 4, 5, 27 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP2, 3, 4, 5, 26 CLARiiON
AX100i
14 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 6, 8, 9, 19 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
9,QLogic QLA4050C−E−SP2, 3, 4, 5, 9 AX100i
15 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 9, 13, 15 , QLogic LAN Only10 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 9, 13, 15, 16 CLARiiON
AX100i
1. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
11. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
12. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
13. Firmware Version 3.00.00.16
14. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Firmware Version 2.00.00.38
20. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
21. The following NICs are not supported: 3COM−3C996B
22. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
25. Driver Version 3.22
26. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
27. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
1. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. Driver Version 5.00.04−d5 Driver is integrated into the kernel.
4. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Driver Version iSCSI Software Initiator 1.0−595 Driver is integrated into the kernel.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
8. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
iSCSI Clusters
Microsoft Windows 2003 [x64]
This table describes the support statements for iSCSI Clusters.
Considerations
• The AX150i and AX150SCi have two front−end iSCSI ports per storage processor.
• Currently, it is not possible to boot a Windows system using an iSCSI disk volume provided by the Microsoft iSCSI initiator. The only currently
supported method for booting a Windows system using an iSCSI disk volume is via a supported HBA.
• When using multiple NICs in the same server, up to two NICs per host are supported to one AX150I array. If multiple NICs are installed, it is
recommended that each be on a different subnet. If multiple NICs are on the same subnet, the MS Advanced configuration setup must be utilized in
order to take advantage of the additional NICs. If the Advanced configuration setup in the MS initiator is not used, additional NICs would be used
typically only in a failover situation.
• When HBAs and NICs are present in the same host, the Microsoft iSCSI initiator must not be used to control the HBAs. The HBA utility is the only
supported interface to the adapter.
• When using the Microsoft iSCSI initiator, all NICs in the same host will use the same iSCSI name. The name will identify the host and the NICs will
not be identifiable.
• When using QLogic iSCSI adapters, each HBA has a unique iSCSI name that identifies the individual HBA in the host.
• Dynamic disks are not supported on an iSCSI session using the Microsoft iSCSI initiator.
• EMC supports up to two nodes with iSCSI Windows server 2003 Cluster environments with the latest MS Initiator.
IBM AIX
IBM AIX
Network External
No. Operating System Host Bus Adapter Configuration Storage Array Boot
1 IBM AIX 5.2 Generic NIC 10/1007, 8, Generic NIC LAN Only9, 10 EMC CLARiiON AX150i1, 2, N
5.2.0.0−085, 6 GbE7, 8 3, 4
Support for Windows 2003 Storage Server is limited to the connection to EMC storage arrays. Currently, Windows 2003 Storage Server is not supported in target mode for iSCSI
configurations.
22. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
23. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
24. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)
25. Firmware Version 2.0.0.38
26. BIOS 1.08
6 MiracleLinux MLSE QLogic QLA4010−E−SP5, 6, 10, 14, 15 , QLogic QLA4010C−E−SP6, 14, 15, 19, 20 LAN Only3 EMC N
[32−Bit] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
5. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Driver is integrated into the kernel.
17. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
18. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
19. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5 MiracleLinux MLSE QLogic QLA4010−E−SP4, 5, 10, 14, 15 , QLogic QLA4010C−E−SP5, 14, 15, 18, 19 LAN Only1 EMC N
[AMD64] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Driver is integrated into the kernel.
14. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Firmware Version 3.00.00.16
16. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
17. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6 MiracleLinux MLSE QLogic QLA4010−E−SP5, 6, 11, 16, 17 , QLogic QLA4010C−E−SP6, 16, 17, 19, 20 LAN Only7 EMC N
[EM64T] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
2. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
5. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
10. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Firmware Version 3.00.00.16
17. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
19. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5 Red Flag DC Server QLogic QLA4010−E−SP4, 5, 7, 9, 14 , QLogic QLA4010C−E−SP4, 5, 6, 7, 8 LAN Only1 EMC N
[32−Bit] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Firmware Version 3.00.00.16
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
8. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
19. Driver Version 5.00.04 Driver is integrated into the kernel.
4 Red Flag DC QLogic QLA4010−E−SP1, 3, 4, 10, 14 , QLogic QLA4010C−E−SP1, 2, 3, 4, 5 LAN Only6 EMC N
Server [AMD64] 5.0 CLARiiON
SP1 AX150i
v2.6.9−34.21AX
1. Firmware Version 3.00.00.16
2. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
5. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
8. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
9. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
18. Driver Version 5.00.04 Driver is integrated into the kernel.
5 Red Flag DC Server QLogic QLA4010−E−SP1, 2, 6, 8, 13 , QLogic QLA4010C−E−SP1, 2, 3, 5, 6 LAN Only4 EMC N
[EM64T] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
3. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
4. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
5. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. Firmware Version 3.00.00.16
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
10. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
12. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
18. Driver Version 5.00.04 Driver is integrated into the kernel.
19. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP4, 6, 9, 24, QLogic LAN Only EMC N See7, 16
QLA4010C−E−SP6, 9, 24 CLARiiON
AX150i
5 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10017, Generic NIC GbE15, 17 LAN Only EMC N See7, 16
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX150i
6 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 6, 9, 12 , QLogic LAN Only7 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 6, 8, 9, 10 CLARiiON
AX150i
7 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)2, 4, 22, 26 CLARiiON
AX150i
8 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP1, 2, 3, 4, 5 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX150i
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10025, Generic NIC GbE25 LAN Only EMC N See7, 16
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX150i
10 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)4, 14, 21, 22 , QLogic QLA4050−E−SP1, 3, 4, 5, CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 14, QLogic QLA4050C−E−SP1, 3, 4, 5, 14 AX150i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP4, 5, 6, 9, 14 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 6, 8, 9, 13 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N See7, 16
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP1, 3, 4, 5, 20 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP1, 3, 4, 5, 19 CLARiiON
AX150i
14 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 11, 21, 22, 23 , QLogic QLA4050−E−SP1, 3, 4, CLARiiON
5, 11,
QLogic QLA4050C−E−SP1, 3, 4, 5, 11 AX150i
15 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 6, 9, 11 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 6, 8, 9, 11 CLARiiON
AX150i
1. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Firmware Version 3.00.00.16
10. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4 Red Hat RHEL [AMD−64] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP8, 12, 14, 21 , QLogic LAN Only EMC N See3, 4
QLA4010C−E−SP12, 14, 21 CLARiiON
AX150i
5 Red Hat RHEL [AMD−64] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/1001, Generic NIC GbE1, 2 LAN Only EMC N See3, 4
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX150i
6 Red Hat RHEL [AMD−64] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP8, 9, 12, 14, 28 , QLogic LAN Only3 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP9, 11, 12, 14, 27 CLARiiON
AX150i
7 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)8, 10, 17, 20 CLARiiON
AX150i
8 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP5, 7, 8, 9, 10 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP5, 7, 8, 9, 10 CLARiiON
AX150i
Red Hat RHEL [AMD−64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N See3, 4
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX150i
10 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)6, 8, 16, 17 , QLogic QLA4050−E−SP5, 6, 7, 8, 9 , CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA4050C−E−SP5, 6, 7, 8, 9 AX150i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP6, 8, 9, 12, 14 , QLogic LAN Only3 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP9, 11, 12, 13, 14 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10015, Generic NIC GbE15 LAN Only EMC N See3, 4
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [AMD−64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP5, 7, 8, 9, 25 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP5, 7, 8, 9, 24 CLARiiON
AX150i
14 Red Hat RHEL [AMD−64] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)8, 16, 17, 19, 23 , QLogic QLA4050−E−SP5, 7, 8, CLARiiON
9, 19, QLogic QLA4050C−E−SP5, 7, 8, 9, 19 AX150i
15 Red Hat RHEL [AMD−64] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP8, 9, 12, 14, 19 , QLogic LAN Only3 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP9, 11, 12, 14, 26 CLARiiON
AX150i
1. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
2. The following NICs are not supported: 3COM−3C996B
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
5. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
10. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
19. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP1, 4, 14, 15 , QLogic LAN Only EMC N See7, 8
QLA4010C−E−SP1, 14, 15 CLARiiON
AX150i
5 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/1006, Generic NIC GbE6, 9 LAN Only EMC N See7, 8
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX150i
6 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 14, 15, 27 , QLogic LAN Only7 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 14, 15, 16, 26 CLARiiON
AX150i
7 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)4, 11, 21, 22 CLARiiON
AX150i
8 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP2, 3, 4, 5, 22 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP2, 3, 4, 5, 22 CLARiiON
AX150i
Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10020, Generic NIC GbE20 LAN Only EMC N See7, 8
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX150i
10 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)4, 10, 11, 12 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 10,QLogic QLA4050C−E−SP2, 3, 4, 5, 10 AX150i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP4, 5, 10, 14, 15 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 13, 14, 15, 16 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10017, Generic NIC GbE17 LAN Only EMC N See7, 8
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP2, 3, 4, 5, 25 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP2, 3, 4, 5, 24 CLARiiON
AX150i
14 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 11, 12, 18, 19 , QLogic QLA4050−E−SP2, 3, 4, CLARiiON
5, 18, QLogic QLA4050C−E−SP2, 3, 4, 5, 18 AX150i
15 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 14, 15, 18 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 14, 15, 16, 18 CLARiiON
AX150i
1. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. The following NICs are not supported: 3COM−3C996B
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
18. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Firmware Version 2.00.00.38
20. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
21. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Driver Version 3.22
24. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
25. Driver Version 5.00.04 Driver is integrated into the kernel.
26. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
27. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
1. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. Driver Version 5.00.04−d5 Driver is integrated into the kernel.
4. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
6. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
7. Driver Version iSCSI Software Initiator 1.0−595 Driver is integrated into the kernel.
8. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
iSCSI Clusters
Microsoft Windows 2003 [x64]
This table describes the support statements for iSCSI Clusters.
Figure 1: A server with a single HBA connected to one port storage processor. Not highly available. Two single points of failure: HBA and SP. PowerPath in a Windows server tells you if that
one path has failed.
Figure 2: Two servers, each with a single HBA connected to the same SP through different ports. Two single points of failure for each server: HBA and SP. However, two servers have
access to the array. PowerPath on each Windows server only tells you if that one path has failed.
Servers can be clustered if they are running the same operating system.
Figure 3: One server with two HBAs connected to a port on each SP. Highly available configuration with one path to each SP. With PowerPath on a server, it can reach any virtual disk if one
SP fails or one HBA fails.
Figure 4: One server with four HBAs connected to an SP port on the two SPs. Highly available configuration with two paths to each SP (multipath). With PowerPath on a server, it can reach
any virtual disk if one SP fails or up to three HBAs fail.
Figure 5: Two servers with one HBA on each connected to an SP port on the two SPs. Not highly available. PowerPath on a server tells you if the path has failed.
Figure 6: Four servers with one HBA on each connected to an SP port on the two SPs. Not highly available. Each server has only one path to a storage processor. PowerPath on a server
tells you if one path has failed.
Figure 7: Two servers with two HBAs each connected to an SP port on the two SPs. Highly available configuration where each server has one path to each storage processor. With
PowerPath on a server, the server can reach any virtual disk if one SP fails or one HBA fails.
If the servers are running the same operating system, they can be clustered.
Figure 8: SAN with Brocade 3250VL2E and with four servers, (supporting up to six), each with one HBA. Each server can reach a port on either SP (see switch zoning
explanation below). The server cannot access the storage system if its HBA fails or if the switch port it connects to fails. With PowerPath on a server, the server can reach any
virtual disk if one SP fails.
If the servers are running the same operating system, they can be clustered.
Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade 3250VL2E, where ports 0 and 4 are for storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3,
5, 6, and 7.
Figure 9: Three servers with two HBAs each can reach one SP port on both SPs. Highly available configuration where each server has one path to each storage processor SP (see switch
zoning explanation below). With PowerPath on a server, the server can reach any virtual disk if one SP fails or one HBA fails.
If the servers are running the same operating system, they can be clustered.
Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2,
3, 5, 6, and 7.
Figure 10: SAN with two Brocade 3250VL2E switches and three servers (and supporting up to six). With two HBAs per server, each can reach a port on each SP. Highly available
configuration where each server has one path to each storage processor. With PowerPath on a server, the server can reach any virtual disk if one SP fails, or one HBA fails.
Note: You also can connect the remaining SP ports A1 and B1 to port 4 on each switch to create more high availability (each server will still be able to reach
virtual disks if a switch fails, because both SPs are connected to alternate switches). Also, if a server with a single HBA is connected to one of the switches, it
will have access to both SPs.
If servers are running the same operating system, they can be clustered.
Figure 11: Three servers each with one HBA. Each server can reach an SP port on each SP (see switch zoning explanation below). With PowerPath on a server, the server can reach any
virtual disk if one SP fails. While each server has one path to each storage processor, the server cannot access the stoarge system if its HBA fails or if the switch port to which it connects
fails. This configuration allows you to connect the maximum 8 servers to an array.
If the servers are running the same operating system, they can be clustered.
Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3,
5, 6, and 7.
Figure 12: Three servers with two HBAs each can reach both SP ports on each SP. Highly available configuration, where each server has two paths to each storage processor. With
PowerPath on a server, the server can reach any virtual disk if one SP fails, a port on the SP fails, or one HBA fails. In addition, with redundant switches, each server will still be able to reach
virtual disks if a switch fails as both SPs are connected to alternate switches.
If any servers are running the same operating system, they can be clustered.
Figure 13: Three servers with two HBAs each can reach one SP port on both SPs. Highly available configuration where each server has one path to each storage system SP (see switch
zoning explanation below). With PowerPath on a server, the server can reach any virtual disk if one SP fails or one HBA fails.
An additional fourth server with two HBAs directly connected to each SP on the storage system. Because all available ports on the switch are occupied, this
configuration allows maximum server utilization.
If the servers are running the same operating system, they can be clustered.
Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2,
3, 5, 6, and 7.
Figure 14: Three servers, each with one HBA. Each server can reach every SP port on each SP (see switch zoning explanation below), because of the inter−switch links on ports 6−7 and
5−4. With PowerPath on the server, the servers can reach any virtual disk if an SP fails.
While each server has multiple paths to each storage processor through the inter=switch links, the server cannot access the storage system if its HBA fails or if
the switch port to which it connects fails. This configuration allows you to connect the maximum 8 servers to an array.
If the servers are running the same operating system, they can be clustered.
Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3, 5, 6,
and 7.
Figure 15: One server with four HBAs. The server can reach every SP port on each SP (see switch zoning explanation below) through more than 1 path, because of the inter−switch links
on ports 7−6 and 5−4. With PowerPath on a server, the server can reach any virtual disk if a storage system SP fails or if fewer than four HBAs fail.
If the servers are running the same operating system, they can be clustered.
Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3, 5, 6,
and 7.
Figure 16: Direct Attach, Single NIC/HBA to one subnet. 1Gb HBA or NIC must be used for direct attach.
Figure 17: Direct Attach, Multiple NIC/HBA to one array. NICs or HBAs must be on different subnets for proper routing. A server cannot connect to the same array using a mix of NICs and
HBAs.
Figure 18: Multiple servers to single storage array. Operating systems do not have to be the same. 1Gb HBA or NIC must be used for direct attach. NICs and HBAs, even if in different
servers, must be on different subnets for proper network routing.
Figure 19: When a switch or router is present, either 10/100/1000 NIC or 1Gb HBA can be used in the server. Operating systems do not have to be the same.
Figure 20: Dual HBAs or NICs. If multiple NICs are on the same subnet, the MS Advanced configuration setup must be utilized in order to take advantage of the additional NICs.
Figure 21: Two NICs or HBAs to separate routers/switched can be supported. However, if two NICs or HBAs are connected to separate switches or routers, they must be on different
subnets. The switch/router must be capable of 1Gb connection.
Figure 22: Single or multiple NICs/HBAs can be supported. A single NIC or HBA can be connected to up to 8 SP ports. The switch/router must be capable of 1Gb connection.
Figure 23: Single or multiple HBAs can be supported. Multiple HBAs from one server can be logged into all ports simultaneously. Router must be capable of 1Gb connection.
Figure 24: Single or multiple NICs can be supported. Multiple NICs from one server can log into all ports, but only 1 NIC per server can be longed into a port at any given time. Router must
be capable of 1 Gb connection.