EMC Support Matrix

November 2006
P/N 300−000−166
ECO 51611 Rev B65
EMC Support Matrix
Copyright EMC Corporation 2006...................................................................................................................................................................................................1
EMC's Policies and Requirements for EMC Support Matrix.........................................................................................................................................................2
End−of−Support Products.................................................................................................................................................................................................2
General Information for AX100........................................................................................................................................................................................................5
Configuration Rules: AX100 Storage Systems.................................................................................................................................................................5
Backup Device Support.....................................................................................................................................................................................................5
Path Definition...................................................................................................................................................................................................................5
AX Series EMC Partner Solutions.....................................................................................................................................................................................5
CLARiiON AX100..............................................................................................................................................................................................................................6
Base Connectivity.............................................................................................................................................................................................................6
Fujitsu Siemens Solaris...................................................................................................................................................................................6
Fujitsu Solaris..................................................................................................................................................................................................6
Haansoft Asianux Server 2.0 [32−Bit]..............................................................................................................................................................7
Haansoft Asianux Server 2.0 [AMD64]............................................................................................................................................................7
Haansoft Asianux Server 2.0 [EM64T]............................................................................................................................................................8
Microsoft Windows 2000..................................................................................................................................................................................9
Microsoft Windows 2003 [x64].......................................................................................................................................................................21
Microsoft Windows 2003 [x86].......................................................................................................................................................................33
MiracleLinux MLSE [32−Bit]..........................................................................................................................................................................62
MiracleLinux MLSE [AMD64].........................................................................................................................................................................62
MiracleLinux MLSE [EM64T].........................................................................................................................................................................63
Novell Netware..............................................................................................................................................................................................64
Oracle Enterprise Linux [32−Bit]....................................................................................................................................................................66
Oracle Enterprise Linux [AMD−64]................................................................................................................................................................71
Oracle Enterprise Linux [EM64T]...................................................................................................................................................................73
Red Flag DC Server [32−Bit].........................................................................................................................................................................76
Red Flag DC Server [AMD64].......................................................................................................................................................................77
Red Flag DC Server [EM64T]........................................................................................................................................................................78
Red Hat RHEL [32−Bit]..................................................................................................................................................................................78
Red Hat RHEL [AMD−64]............................................................................................................................................................................120
Red Hat RHEL [EM64T]..............................................................................................................................................................................125
SuSE SLES [32−Bit]....................................................................................................................................................................................148
SuSE SLES [AMD−64]................................................................................................................................................................................170
SuSE SLES [EM64T]...................................................................................................................................................................................172
SuSE SLES [x86_64]...................................................................................................................................................................................179
Sun Solaris..................................................................................................................................................................................................182
VMware ESX Server....................................................................................................................................................................................184
Cluster Software............................................................................................................................................................................................................194
Microsoft Windows 2000..............................................................................................................................................................................194
Microsoft Windows 2003 [x64].....................................................................................................................................................................194
Microsoft Windows 2003 [x86].....................................................................................................................................................................194
Red Hat RHEL [32−Bit]................................................................................................................................................................................194
Red Hat RHEL [EM64T]..............................................................................................................................................................................195
Red Hat RHEL [IA64]...................................................................................................................................................................................195
Fibre Connectivity: Switch.............................................................................................................................................................................................195
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................195
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................196
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................196
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................196
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................196
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................197
Microsoft Windows 2000..............................................................................................................................................................................197
Microsoft Windows 2003 [x64].....................................................................................................................................................................198
Microsoft Windows 2003 [x86].....................................................................................................................................................................200
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................202
MiracleLinux MLSE [AMD64].......................................................................................................................................................................202
MiracleLinux MLSE [EM64T].......................................................................................................................................................................202
Novell Netware............................................................................................................................................................................................203
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................203
Oracle Enterprise Linux [EM64T].................................................................................................................................................................203
Red Flag DC Server [32−Bit].......................................................................................................................................................................204
Red Flag DC Server [AMD64].....................................................................................................................................................................204
Red Flag DC Server [EM64T]......................................................................................................................................................................204
Red Hat RHEL [32−Bit]................................................................................................................................................................................205
Red Hat RHEL [AMD−64]............................................................................................................................................................................206
Red Hat RHEL [EM64T]..............................................................................................................................................................................207
Red Hat RHEL [IA64]...................................................................................................................................................................................208
SuSE SLES [32−Bit]....................................................................................................................................................................................208
SuSE SLES [AMD−64]................................................................................................................................................................................209
SuSE SLES [EM64T]...................................................................................................................................................................................210
SuSE SLES [IA64].......................................................................................................................................................................................211
SuSE SLES [x86_64]...................................................................................................................................................................................211
Sun Solaris..................................................................................................................................................................................................212
Sun Solaris x86............................................................................................................................................................................................212
VMware ESX Server....................................................................................................................................................................................212
General Information for AX150....................................................................................................................................................................................................214
Configuration Rules: AX150 Storage Systems.............................................................................................................................................................214
Backup Device Support.................................................................................................................................................................................................214
Path Definition...............................................................................................................................................................................................................214
Remote Replication.......................................................................................................................................................................................................214

AX Series EMC Partner Solutions...............................................................................................................................................................................................215


CLARiiON AX150..........................................................................................................................................................................................................................216
Base Connectivity.........................................................................................................................................................................................................216
Fujitsu Siemens Solaris...............................................................................................................................................................................216
Fujitsu Solaris..............................................................................................................................................................................................216
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................217
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................217
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................218
Microsoft Windows 2000..............................................................................................................................................................................219
Microsoft Windows 2003 [x64].....................................................................................................................................................................232
Microsoft Windows 2003 [x86].....................................................................................................................................................................245
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................275
MiracleLinux MLSE [AMD64].......................................................................................................................................................................275
MiracleLinux MLSE [EM64T].......................................................................................................................................................................276
Novell Netware............................................................................................................................................................................................277
EMC Support Matrix
CLARiiON AX150
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................278
Oracle Enterprise Linux [AMD−64]..............................................................................................................................................................283
Oracle Enterprise Linux [EM64T].................................................................................................................................................................284
Red Flag DC Server [32−Bit].......................................................................................................................................................................288
Red Flag DC Server [AMD64].....................................................................................................................................................................289
Red Flag DC Server [EM64T]......................................................................................................................................................................289
Red Hat RHEL [32−Bit]................................................................................................................................................................................290
Red Hat RHEL [AMD−64]............................................................................................................................................................................320
Red Hat RHEL [EM64T]..............................................................................................................................................................................323
SuSE SLES [32−Bit]....................................................................................................................................................................................344
SuSE SLES [AMD−64]................................................................................................................................................................................349
SuSE SLES [EM64T]...................................................................................................................................................................................351
SuSE SLES [x86_64]...................................................................................................................................................................................356
Sun Solaris..................................................................................................................................................................................................359
VMware ESX Server....................................................................................................................................................................................360
Cluster Software............................................................................................................................................................................................................369
Microsoft Windows 2000..............................................................................................................................................................................369
Microsoft Windows 2003 [x64].....................................................................................................................................................................370
Microsoft Windows 2003 [x86].....................................................................................................................................................................370
Red Hat RHEL [32−Bit]................................................................................................................................................................................370
Red Hat RHEL [EM64T]..............................................................................................................................................................................370
Red Hat RHEL [IA64]...................................................................................................................................................................................370
Fibre Connectivity: Switch.............................................................................................................................................................................................370
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................370
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................371
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................371
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................371
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................372
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................372
Microsoft Windows 2000..............................................................................................................................................................................373
Microsoft Windows 2003 [x64].....................................................................................................................................................................374
Microsoft Windows 2003 [x86].....................................................................................................................................................................376
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................377
MiracleLinux MLSE [AMD64].......................................................................................................................................................................378
MiracleLinux MLSE [EM64T].......................................................................................................................................................................379
Novell Netware............................................................................................................................................................................................379
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................379
Oracle Enterprise Linux [AMD−64]..............................................................................................................................................................380
Oracle Enterprise Linux [EM64T].................................................................................................................................................................381
Red Flag DC Server [32−Bit].......................................................................................................................................................................382
Red Flag DC Server [AMD64].....................................................................................................................................................................382
Red Flag DC Server [EM64T]......................................................................................................................................................................383
Red Hat RHEL [32−Bit]................................................................................................................................................................................383
Red Hat RHEL [AMD−64]............................................................................................................................................................................384
Red Hat RHEL [EM64T]..............................................................................................................................................................................385
SuSE SLES [32−Bit]....................................................................................................................................................................................387
SuSE SLES [AMD−64]................................................................................................................................................................................388
SuSE SLES [EM64T]...................................................................................................................................................................................389
SuSE SLES [x86_64]...................................................................................................................................................................................390
Sun Solaris..................................................................................................................................................................................................390
Sun Solaris x86............................................................................................................................................................................................391
VMware ESX Server....................................................................................................................................................................................391

Switched Fabric Topology Parameters......................................................................................................................................................................................393

AX100i Rules.................................................................................................................................................................................................................................397
Switches, Routers, Network Interface Cards (NICs), and iSCSI Host Bus Adapters (HBAs) ......................................................................................397
Environments and Configurability ................................................................................................................................................................................397
Considerations .............................................................................................................................................................................................................397

CLARiiON AX100i.........................................................................................................................................................................................................................398
Native iSCSI..................................................................................................................................................................................................................398
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................398
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................398
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................398
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................399
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................399
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................399
Microsoft Windows 2000..............................................................................................................................................................................399
Microsoft Windows 2003 [x64].....................................................................................................................................................................400
Microsoft Windows 2003 [x86].....................................................................................................................................................................401
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................401
MiracleLinux MLSE [AMD64].......................................................................................................................................................................402
MiracleLinux MLSE [EM64T].......................................................................................................................................................................402
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................403
Oracle Enterprise Linux [AMD−64]..............................................................................................................................................................403
Oracle Enterprise Linux [EM64T].................................................................................................................................................................404
Red Flag DC Server [32−Bit].......................................................................................................................................................................404
Red Flag DC Server [AMD64].....................................................................................................................................................................405
Red Flag DC Server [EM64T]......................................................................................................................................................................405
Red Hat RHEL [32−Bit]................................................................................................................................................................................406
Red Hat RHEL [AMD−64]............................................................................................................................................................................407
Red Hat RHEL [EM64T]..............................................................................................................................................................................408
SuSE SLES [32−Bit]....................................................................................................................................................................................409
SuSE SLES [AMD−64]................................................................................................................................................................................410
SuSE SLES [EM64T]...................................................................................................................................................................................410
SuSE SLES [IA64].......................................................................................................................................................................................411
SuSE SLES [x86_64]...................................................................................................................................................................................411
VMware ESX Server....................................................................................................................................................................................411
iSCSI Clusters...............................................................................................................................................................................................................411
Microsoft Windows 2003 [x64].....................................................................................................................................................................411
Microsoft Windows 2003 [x86].....................................................................................................................................................................412
AX150i Rules.................................................................................................................................................................................................................................413
Configuration Rules: AX150i Storage Systems.............................................................................................................................................................413
Switches, Routers, NICs...............................................................................................................................................................................................413
Environment and Configurability...................................................................................................................................................................................413
Considerations..............................................................................................................................................................................................................413
EMC Support Matrix
CLARiiON AX150i.........................................................................................................................................................................................................................414
Native iSCSI..................................................................................................................................................................................................................414
Haansoft Asianux Server 2.0 [32−Bit]..........................................................................................................................................................414
Haansoft Asianux Server 2.0 [AMD64]........................................................................................................................................................414
Haansoft Asianux Server 2.0 [EM64T]........................................................................................................................................................414
Haansoft Linux 2005 Server Asianux Inside [32−Bit]..................................................................................................................................415
Haansoft Linux 2005 Server Asianux Inside [AMD64].................................................................................................................................415
Haansoft Linux 2005 Server Asianux Inside [EM64T].................................................................................................................................415
IBM AIX........................................................................................................................................................................................................415
Microsoft Windows 2000..............................................................................................................................................................................416
Microsoft Windows 2003 [x64].....................................................................................................................................................................416
Microsoft Windows 2003 [x86].....................................................................................................................................................................417
MiracleLinux MLSE [32−Bit]........................................................................................................................................................................417
MiracleLinux MLSE [AMD64].......................................................................................................................................................................418
MiracleLinux MLSE [EM64T].......................................................................................................................................................................419
Oracle Enterprise Linux [32−Bit]..................................................................................................................................................................419
Oracle Enterprise Linux [AMD−64]..............................................................................................................................................................419
Oracle Enterprise Linux [EM64T].................................................................................................................................................................420
Red Flag DC Server [32−Bit].......................................................................................................................................................................420
Red Flag DC Server [AMD64].....................................................................................................................................................................421
Red Flag DC Server [EM64T]......................................................................................................................................................................421
Red Hat RHEL [32−Bit]................................................................................................................................................................................422
Red Hat RHEL [AMD−64]............................................................................................................................................................................423
Red Hat RHEL [EM64T]..............................................................................................................................................................................424
SuSE SLES [32−Bit]....................................................................................................................................................................................425
SuSE SLES [AMD−64]................................................................................................................................................................................425
SuSE SLES [EM64T]...................................................................................................................................................................................426
SuSE SLES [IA64].......................................................................................................................................................................................426
SuSE SLES [x86_64]...................................................................................................................................................................................427
iSCSI Clusters...............................................................................................................................................................................................................427
Microsoft Windows 2003 [x64].....................................................................................................................................................................427
Microsoft Windows 2003 [x86].....................................................................................................................................................................427

User Installation Diagrams..........................................................................................................................................................................................................428

Professional Installation Diagrams.............................................................................................................................................................................................434

AX100i Configuration Diagrams..................................................................................................................................................................................................436


Copyright EMC Corporation 2006
Copyright © 2001, 2006 EMC Corporation. All Rights Reserved.

EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice.

THE INFORMATION IN THIS PUBLICATION IS PROVIDED "AS IS". EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY
KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS FOR A PARTICULAR PURPOSE.

Use, copying, and distribution of any EMC software described in this publication requires an applicable software license.

Trademark Information

EMC2, EMC, EMC ControlCenter, AlphaStor, ApplicationXtender, Captiva, Catalog Solution, Celerra, CentraStar, CLARalert, CLARiiON, ClientPak, Connectrix,
Co−StandbyServer, Dantz, Direct Matrix Architecture, DiskXtender, DiskXtender 2000, Documentum, EmailXaminer, EmailXtender, EmailXtract, eRoom,
FLARE, HighRoad, InputAccel, Navisphere, nLayers, OpenScale, PowerPath, Rainfinity, RepliStor, ResourcePak, Retrospect, Smarts, SnapShotServer,
SnapView/IP, SRDF, Symmetrix, TimeFinder, VisualSAN, VSAM−Assist, WebXtender, where information lives, Xtender, and Xtender Solutions are registered
trademarks and EMC Developers Program, EMC OnCourse, EMC Proven, EMC Snap, EMC Storage Administrator, Acartus, Access Logix, ArchiveXtender,
Authentic Problems, Automated Resource Manager, AutoStart, AutoSwap, AVALONidm, C−Clip, Celerra Replicator, Centera, CLARevent, Codebook
Correlation Technology, Common Information Model, CopyCross, CopyPoint, DatabaseXtender, Direct Matrix, EDM, E−Lab, Enginuity, FarPoint, Global File
Virtualization, Graphic Visualization, InfoMover, Infoscape, Invista, MediaStor, MirrorView, NetWin, NetWorker, OnAlert, Powerlink, PowerSnap, RecoverPoint,
RepliCare, SafeLine, SAN Advisor, SAN Copy, SAN Manager, SDMS, SnapImage, SnapSure, SnapView, StorageScope, SupportMate, SymmAPI,
SymmEnabler, Symmetrix DMX, UltraPoint, UltraScale, Viewlets, and VisualSRM are trademarks of EMC Corporation. All other trademarks used herein are the
property of their respective owners.

11/02/2006 1 Copyright EMC Corporation 2006


EMC's Policies and Requirements for EMC Support Matrix
EMC's Support Matrix Policies and Requirements

This section describes EMC's policies and requirements for the EMC Support Matrix document.

Purpose and Limitations of this Document

This document is being provided for informational purposes only and may change at any time. This version supersedes and replaces all previous versions. The
information is to serve only as a guide for those configurations/products which EMC has qualified. The information in this document is a subset of the
information that can be found on the E−Lab Navigator tool which is available for all EMC personnel, customers and partners. The E−Lab Navigator site may be
reached at http://elabnavigator.emc.com.

The information included in this document is intended as a guide in the configuration of systems for EMC's products. It is not intended to be the sole resource
for system configuration. For more information or answers to questions not found in this document, please see EMC's website, other EMC documentation, such
as EMC's Host Connectivity Guides, EMC Networked Storage Topology Guide, EMC CLARiiON Open Systems Configuration Guide, relevant vendor
documentation, or contact your EMC Sales or EMC Customer Service representative.
For Symmetrix 4.x support, please look at the Symmetrix 8000 Series section and check the footnotes for model/microcode compatibility. EMC employees can
obtain older revisions of ESM containing more Symmetrix 4.x information from the Symmetrix Service Readiness group.
For a complete listing of any known issues with the current support matrix content, please review the ESM Errata on E−Lab Navigator. To report any issues with
the content contained within the support matrix, follow the steps documented on the Contacts link on E−Lab Navigator. E−Lab Navigator can be reached at
http://elabnavigator.emc.com.

Policies for Qualifying Systems

Policies and procedures for support of EMC products are set forth in the customer's applicable agreements. EMC's publication of information relating to system
configurations covers only those outlined in this document or by approval from EMC Engineering. Other system configurations not found in this document are
not qualified without EMC Engineering approval. EMC has qualified hardware and software provided only by the vendors listed in this document, and host
systems, hardware and software from other vendors are not qualified, and may never be. Please contact your EMC Sales or EMC Customer Service
representative for updates or information not included in this document.

EMC maintains a large collection of the products listed above as well as third−party application software for qualification with EMC's storage systems and to
simulate customer environments, but you must consult the vendors for information about their system internals, such as hardware and associated drivers.

Policy for Future Qualification of Operating System Software Releases

The information in this document is maintained by EMC and EMC strives to update this document with new releases of hardware, operating systems, firmware,
BIOS, switch software, etc., as they become available from the vendors. EMC works with the vendors during their development and release processes in order
to be fully informed at the time the vendors release new versions. EMC does not announce qualification prior to vendors' General Availability. In some cases,
EMC may choose to perform regression testing following the vendors' GA; in these cases and in cases where advance preparation is not possible, EMC may
validate and qualify vendors' products as appropriate after they have been released. For early support of such products, including vendor beta participation,
contact your EMC Sales or EMC Customer Service representative.

Policy for End−of−Life Support

EMC strives to continue support for any installed platforms, but may remove support from this host matrix for new installations within three months after the
vendor has announced that this platform has reached the end of life. EMC will continue support for existing installations of hardware, operating systems, and
components that the vendor has officially declared to have reached end of life as long as support is available from the vendor.

End−of−Support Products

End−of−Support
No. Component Name Date Description
1 05/30/200614 End of support
4/30/06
2 Caldera UNIXWare 7.0.1, Caldera UNIXWare 7.1.1, DG DG/UX R4.11MU03, DG DG/UX R4.20MU06, DG DG/UX 05/15/20067 Discontinuity
R4.20MU07 support for
this
environment in
the June
publication.
3 Egenera BladeFrame SW 4.0, Fujitsu Siemens Primergy BladeFrame SW 4.0 08/22/200617 PAN Manager
4.0.0 release
is officially
retired by
Egenera.
Egenera
support policy
specifies that
only the latest
version within
a major
release family
is supported.

11/02/2006 2 EMC's Policies and Requirements for EMC Support Matrix


EMC's Policies and Requirements for EMC Support Matrix

End−of−Support
No. Component Name Date Description
4 EMC PowerPath (PPVM) 4.0, EMC PowerPath (PPVM) 4.1 03/15/20066 This version of
EMC
Powerpath is
scheduled to
reach EOSL
March 30,
2006.
5 EMC PowerPath 2.0.0, EMC PowerPath 2.0.1, EMC PowerPath 2.0.2, EMC PowerPath 2.0.3, EMC PowerPath 2.0.4, 05/10/20069 This release of
EMC PowerPath 2.1.0, EMC PowerPath 2.1.1, EMC PowerPath 2.1.2, EMC PowerPath 2.1.3, EMC PowerPath 3.0.0, PowerPath
EMC PowerPath 3.0.1, EMC PowerPath 3.0.2, EMC PowerPath 3.0.2 b069, EMC PowerPath 3.0.2 b41, EMC PowerPath has reached
3.0.3 b 00310, EMC PowerPath 3.0.3 b065, EMC PowerPath 3.0.4 b012, EMC PowerPath 3.0.4.2, EMC PowerPath 3.0.5 the end of it's
b032, EMC PowerPath 3.0.6, EMC PowerPath 3.0.6 b010, EMC PowerPath 3.0.7, EMC PowerPath 3.0.7 b007, EMC service life
PowerPath 4.0.0, EMC PowerPath 4.0.1, EMC PowerPath 4.0.2 and is no
longer
supported.
6 EMC PowerPath 3.0.3 03/30/20066 This version of
EMC
Powerpath is
scheduled to
reach EOSL
March 30,
2006.
7 EMC PowerPath 4.0.3, EMC PowerPath 4.1, EMC PowerPath 4.2 06/30/200611 This release of
PowerPath will
reach end of
it's service life
on 6/30/2006
at which point
it will no
longer be
supported.
8 FCS Solaris 2.6, Fujitsu Siemens Solaris 2.6, Fujitsu Solaris 2.6 07/31/200613 Solaris 2.6
went End Of
Life by Sun in
February
2001. These
configurations
will be
removed from
the ESM
starting in
September
2006.
9 HPQ HP 9000 D370, HPQ HP 9000 D380 11/16/200616 support will be
removed from
the EMC
support matrix
as of
December
2006.
10 HPQ HP 9000 D390 04/14/200715 support will be
removed from
the EMC
support matrix
as of May
2007.
11 HPQ HP 9000 R380, HPQ MC/Service Guard 11.14, HPQ MC/Service Guard 11.15, NEC NX7000 27, NEC NX7000 37, 11/19/200616 support will be
NEC NX7000 D280, NEC NX7000 D380, NEC TX7 D280 removed from
the EMC
support matrix
as of
December
2006.
12 HPQ HP 9000 R390 11/16/299615 support will be
removed from
the EMC
support matrix
as of May
2007.
13 HPQ HP 9000 rp2450 11/19/200618 HP−UX
Rp2450
support will be
removed from
the EMC
support matrix
as of
December
2006.
14 HPQ HP−UX 11.0 11/19/200621 HP−UX 11.00
support will be
removed from
the EMC
support matrix
as of
December
2006.
15 HPQ MPE/ix 5.0, HPQ MPE/ix 5.5, HPQ MPE/ix 6.0, HPQ MPE/ix 6.5, HPQ MPE/ix 6.5.02, HPQ MPE/ix 7.0.01, HPQ 11/19/20064 MPE support
MPE/ix 7.520 will be
removed from
the EMC
support matrix
as of
December
2006.
16 IBM z/OS 1.4 03/31/20072 IBM plans to
discontinue
service for this
version of
z/OS on
03/31/2007.

11/02/2006 3 EMC's Policies and Requirements for EMC Support Matrix


EMC's Policies and Requirements for EMC Support Matrix

End−of−Support
No. Component Name Date Description
17 IBM z/OS 1.4, IBM z/OS 1.5, IBM z/OS.e 1.4, IBM z/OS.e 1.5 03/31/20071 To be
discontinued
18 NEC NX7000 D390, NEC TX7 D390 04/15/200715 support will be
removed from
the EMC
support matrix
as of May
2007.
19 NEC NX7000 rp2450, NEC TX7 rp2450 11/19/200619 NEC rp2450
support will be
removed from
the EMC
support matrix
as of
December
2006.
20 Novell Netware 5.00 SP4, Novell Netware 5.00 SP6A, Novell Netware 5.10, Novell Netware 5.10 SP2, Novell Netware 5.10 05/01/20065 Discontinuing
SP2A, Novell Netware 5.10 SP3, Novell Netware 5.10 SP4, Novell Netware 5.10 SP5, Novell Netware 5.10 SP6, Novell support for
Netware 5.10 SP7, Novell Netware 6.0 SP1, Novell Netware 6.0 SP2, Novell Netware 6.0 SP3, Novell Netware 6.0 SP4, Novell
Novell Netware 6.0 SP5 Netware
EOSL Product
21 Red Hat RHEL [32−Bit] 2.1 U2 v2.4.9−e.24, Red Hat RHEL [32−Bit] 2.1 U2+ v2.4.9−e.25, Red Hat RHEL [32−Bit] 2.1 U2+ 06/25/200612 To align with
v2.4.9−e.27, Red Hat RHEL [32−Bit] 2.1 U3 AS/ES v2.4.9−e.35, Red Hat RHEL [32−Bit] 2.1 U3+ AS/ES v2.4.9−e.38, Red EMC Software
Hat RHEL [32−Bit] 2.1 U4 AS/ES v2.4.9−e.40, Red Hat RHEL [32−Bit] 2.1 U4+ AS/ES v2.4.9−e.43, Red Hat RHEL Support, this
[32−Bit] 2.1 U5 AS/ES v2.4.9−e.49, Red Hat RHEL [32−Bit] 2.1 U6 AS/ES v2.4.9−e.57, Red Hat RHEL [32−Bit] 2.1 U6+ product is
AS/ES v2.4.9−e.59, Red Hat RHEL [32−Bit] 2.1 U7 AS/ES v2.4.9−e.62, Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.41, marked EOSL.
Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.43, Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.47, Red Hat RHEL [IA64] 2.1
AS/ES v2.4.18−e.52, Red Hat RHEL [IA64] 2.1 U7 AS/ES v2.4.18−e.56
22 Red Hat RHEL [IA64] 2.1 AS/ES v2.4.18−e.31 09/30/20058 EOS RHEL
2.1 [IA64]
v2.4.18−e.31
− see footnote
38398
23 Sun Solaris 2.6 05/10/20063 Sun Solaris
2.6 will be End
of Support as
of June 2006.
1. To be discontinued
2. IBM plans to discontinue service for this version of z/OS on 03/31/2007.
3. Sun Solaris 2.6 will be End of Support as of June 2006.
4. MPE support will be removed from the EMC support matrix as of December 2006.
5. Discontinuing support for Novell Netware EOSL Product
6. This version of EMC Powerpath is scheduled to reach EOSL March 30, 2006.
7. Discontinuity support for this environment in the June publication.
8. EOS RHEL 2.1 [IA64] v2.4.18−e.31 − see footnote 38398
9. This release of PowerPath has reached the end of it's service life and is no longer supported.
10. Supported with HP−UX 11.0, 11i only − HP−UX 10.20 supported dropped with this version.
11. This release of PowerPath will reach end of it's service life on 6/30/2006 at which point it will no longer be supported.
12. To align with EMC Software Support, this product is marked EOSL.
13. Solaris 2.6 went End Of Life by Sun in February 2001. These configurations will be removed from the ESM starting in September 2006.
14. End of support 4/30/06
15. support will be removed from the EMC support matrix as of May 2007.
16. support will be removed from the EMC support matrix as of December 2006.
17. PAN Manager 4.0.0 release is officially retired by Egenera. Egenera support policy specifies that only the latest version within a major release family is supported.
18. HP−UX Rp2450 support will be removed from the EMC support matrix as of December 2006.
19. NEC rp2450 support will be removed from the EMC support matrix as of December 2006.
20. Requires Symmetrix microcode:
5266.40.28 or higher
5566.40.27 or higher
5267.25.17 or higher
5567.32.16 or higher
5568.34.14 or higher
21. HP−UX 11.00 support will be removed from the EMC support matrix as of December 2006.

11/02/2006 4 EMC's Policies and Requirements for EMC Support Matrix


General Information for AX100
Configuration Rules: AX100 Storage Systems
Note: In this document, array means storage system.
• A total of 8 servers are supported per AX100 storage system.
• A total of 8 Host Bus Adapters (HBAs) are supported on single−SP storage systems.
• A total of 16 HBAs are supported on dual−SP storage systems.
• A total of 4 storage systems per server are supported.
• A total of 256 virtual disks per storage system are supported.
• User installable HBAs are limited to the Emulex and the QLogic E models.
• HBAs from different manufacturers cannot be mixed in the same server.
• User installable switches are limited to the Qlogic SB3050−08A−E and the Brocade DS−220B−FF−D. Pre−configured zoning or the Zoning Wizard
must be used with these switches to be user installable. All other supported switches are not user installable and require professional installation.
• Switches from different manufacturers cannot be mixed in the same SAN.
• If an AX series system is connected to a server, no other type of storage system can be connected to that server.
• A server must be connected to a storage system either directly or through a switch. A server CANNOT be connected to the SAME storage system
both directly and through a switch.
• All direct connect configurations are user installable.
• For example, figures 1 and 2.
• Any switch configuration utilizing an Inter Switch Link (ISL) is not user installable. No more than 2 switches can be connected with an ISL.
• For example, figures 14 and 15.
• In any supported multiple−server configuration, the servers can run the same operating system or any combination of supported operating systems.
• The snapshot feature requires that the source and secondary servers are connected to the same SP. As a result, the snapshot feature is not
supported for figures 4 and 5.
• PowerPath must be installed on all attached servers for all configurations.
• A clustered configuration requires one or more HBAs per server and a single−SP or dual−SP storage system.
• 2 to 8 nodes are supported in a clustered configuration.
• All nodes in a cluster configuration must run the same operating system. Diagrams may show other operating systems, but dissimilar operating
systems cannot be clustered.
• All nodes in a cluster configuration must be connected to the same SPs.

• For example, figures 2, 7 and 8.


• The installation of an operating system on a storage system for the purpose of booting the server from the storage system is not a user installable
option.
• Boot from a storage system on clustered servers running Windows 2000 require a dedicated boot HBA.
• Boot from a storage system on clustered servers running Windows 2003 DO NOT require a dedicated boot HBA.

Backup Device Support


EMC's testing and qualification responsibilities only apply to SAN (switch) attached backup devices. SAN attached backup configurations include a backup
device connected to a port on the switch. These configurations are not currently user installable. Please refer to the EMC ESM for SAN attached backup
supported configurations.

For tape devices connected directly to a backup host, EMC strongly recommends that the component vendors' supported configuration matrices are reviewed
(host configuration matrix for compatibility with SCSI or Fibre Channel interface used to connect to tape device, tape device vendor for compatibility with
selected SCSI or Fibre Channel interface and backup software vendor for compatibility with the tape device).

Path Definition
A path is a connection between an HBA port and a target an SP port in a storage system. Each HBA that is directly connect to, or zoned through, a switch to an
SP port is considered an initiator of that SP port. An HBA port can be zoned through different switch ports to the same SP port or to different SP ports, resulting
in multiple paths between the HBA port and an SP.

AX Series EMC Partner Solutions


EMC has a wide variety of distribution partners that offer the AX Series product. The information in this document contains supported components that are
'standard' across our AX Series product solutions. EMC's AX Series partners offer a wider variety of the AX Series solutions to fit your business needs. For a
complete listing of current EMC distribution partners and their AX Series specific solutions, please refer to the EMC AX Series website with direct links to these
partners. The specific link to this EMC site is:

http://www.emc.com/partnersalliances/partners/sp.jsp
For general information about the EMC AX Series Storage System, please follow the link below:
http://www.emc.com/products/systems/clariion/ax150/index.jsp

11/02/2006 5 General Information for AX100


CLARiiON AX100
Base Connectivity
Fujitsu Siemens Solaris

Fujitsu Siemens Solaris


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Fujitsu PCI Fujitsu Siemens: LP10000−E (GP70F−CF33)1, 2, 3, 4, 5, 6, 7, 8, 14 , LP11000−E FC−AL, EMC N
PRIMEPOWER: 200, 250, Siemens (GP70F−CF36)3, 5, 6, 21, LP9002−E (LP9002L−E) GP70F−CF301, 3, 4, 6, 9, 10, 13, 14, 15 , FC−SW CLARiiON
400, 450, 600, 650, 850 Solaris 1011, LP9802−E (GP70F−CF31)1, 2, 3, 4, 5, 6, 7, 8, 9, 10 AX100
12

2 Fujitsu Siemens Fujitsu PCI Fujitsu Siemens: LP10000−E (GP70F−CF33)1, 2, 3, 4, 5, 6, 7, 8, 14, 16, 17, 18, 19 , FC−AL, EMC N
PRIMEPOWER: 200, 250, Siemens LP11000−E (GP70F−CF36)3, 5, 6, 16, 17, 18, 19, 21 , LP9802−E (GP70F−CF31)1, 2, 3, 4, 5, FC−SW CLARiiON
400, 450, 600, 650, 850 Solaris: 8, 9 6, 7, 8, 14, 16, 17, 18, 19 AX10020
1. Driver Version 6.02f
2. Firmware Version 1.91a1
3. FCode Value 1.41a4
4. Driver Version 6.02hx2
5. SNIA HBA API Supported.
6. FCode Value 1.50a4
7. Firmware Version 1.90a4
8. Driver Version 6.02e
9. The SAN driver is part of the OS.
10. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
11. FSC requires all patches for Solaris 10 be obtained through FSC in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers running
Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
12. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
13. Firmware Version 3.92a3
14. Driver Version 6.01f
15. Driver Version 5.01e
16. Driver Version SAN 4.4.7a
17. Driver Version SAN 4.4.10
18. Driver Version SAN 4.4.8
19. Driver Version SAN 4.4.9
20. AX100 requires the following minimum Flare revs:
AX100 02.16.102.5.004
AX100SC 02.16.101.5.004
21. Firmware Version 2.10a9

Fujitsu Solaris

Fujitsu Solaris
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot Comments
1 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex: LP10000−E9, 13, 14, 15, 16, 17, 18, 19, 22, 23 , FC−AL, EMC Y See3
2500, 450, 650, 850, 900 1020, 21 LP9802−E9, 13, 14, 15, 16, 17, 18, 19, 22 FC−SW CLARiiON
AX1004
2 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC224, PW008FC324 FC−AL, EMC N See3
2500, 450, 650, 850, 900 1020, 21 FC−SW CLARiiON
AX1004
3 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex LP9802−E9, 10, 11, 12, 13, 14, 15, 16, 17, 18 FC−AL, EMC Y See3
2500, 450, 650, 850, 900 8 02/027 FC−SW CLARiiON
AX1004
4 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC21, 2, 5, 6, PW008FC31, 2, 5, 6 FC−AL, EMC N See3
2500, 450, 650, 850, 900 8 02/027 FC−SW CLARiiON
AX1004
5 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex LP9802−E9, 10, 11, 12, 13, 14, 15, 16, 17, 18 FC−AL, EMC Y See3
2500, 450, 900 9 04/038 FC−SW CLARiiON
AX1004
6 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC21, 2, 5, 6, PW008FC31, 2, 5, 6 FC−AL, EMC N See3
2500, 450, 900 9 04/038 FC−SW CLARiiON
AX1004
7 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris PCI Emulex LP9802−E9, 10, 11, 12, 13, 14, 15, 16, 17, 18 FC−AL, EMC Y See3
9 12/028 FC−SW CLARiiON
AX1004
8 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris PCI Fujitsu: PW008FC21, 2, 5, 6, PW008FC31, 2, 5, 6 FC−AL, EMC N See3
9 12/028 FC−SW CLARiiON
AX1004
1. Driver Version PFCA 3.0
2. Driver Version PFCA 2.2.1
3. For use in Asia Pacific/Japan only. Refer to Fujitsu Siemens Base Connectivity information for US/Europe.
4. AX100 requires the following minimum Flare revs:
AX100 02.16.102.5.004
AX100SC 02.16.101.5.004
5. Driver Version PFCA 2.2.1 requires patch 912069−21.
6. Driver Version PFCA 3.0 requires patch 914180−01.
7. Fujitsu requires all patches for Solaris 8 be obtained through Fujitsu in the form of a Solaris 8 PTF patch CD. The current patch CD is Solaris 8 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 8: 108528−29, 117000−05, 108974−50,109885−20, 110918−06, 117350−39 and PTF R06081
8. Fujitsu requires that all patches for Solaris 9 be obtained through Fujitsu in the form of a Solaris 9 PTF patch CD. The current patch CD is Solaris 9 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 9: 112233−12, 112834−06, 113277−45, 117171−17, 118558−30, and PTF R06081
9. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
10. Driver Version SAN 4.4.7a
11. Driver Version 6.01f
12. Driver Version SAN 4.4.8
13. Firmware Version 1.91a1
14. FCode Value 1.41a4
15. Driver Version 6.02f
16. Driver Version 6.02e
17. FCode Value 1.50a4

11/02/2006 6 CLARiiON AX100


CLARiiON AX100

18. SNIA HBA API Supported.


19. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
20. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
21. Fujitsu requires all patches for Solaris 10 be obtained through Fujitsu in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers
running Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
22. Driver Version SAN in Solaris 10 U1 (01/06)
23. Firmware Version 1.90a4
24. Use the Solaris 10 bundled driver PFCA 3.0 which requires patch 120811−02. PFCA Utility 3.0 and its patch 914180−01 need to be installed.

Haansoft Asianux Server 2.0 [32−Bit]

Haansoft Asianux Server 2.0 [32−Bit]


Host Bus Storage External
No. Host System Operating System Host Bus Adapter Topology Array Boot
1 HPQ Proliant: DL3201, DL360(G2)1, DL3601, DL380(G2)1, DL380(G3)1, DL3801, Haansoft Asianux PCI QLogic FC−AL, EMC Y
DL580(G2)1, DL5801, ML350(G2)1, ML350(G3)1, ML3501, ML370(G2)1, ML3701, Server 2.0 [32−Bit] SP1 QLE220−E−SP2, FC−SW CLARiiON
ML530(G2)1, ML530(G3)1, ML5301, ML5701, ML7501 v2.6.9−34.21AX3, 4 5, 6, 7 AX100
2 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Haansoft Asianux PCI Emulex FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express LPe111−E5, 8, FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.21AX3, 4 9, 10 AX100
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)1, DL380(G4)1, DL580(G3)1, ML350(G4)1, ML370(G4)1;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
3 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 5, 6, 7 AX100
4 Dell PowerEdge 1950 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express QLE220−E−SP5, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 6, 7 AX100
5 Dell PowerEdge: 2900, 2950, 6950; Haansoft Asianux PCI Emulex FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, LPe111−E5, 8, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX3, 4 PCI−X 9, 10 AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)1 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 PCI−X 5, 6, 7 AX100
7 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, 6950; Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP5, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX3, 4 PCI−X 6, 7 AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
8 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 PCI−X11 5, 6, 7 AX100
9 Digital Henge SH4500R4; Haansoft Asianux PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; Server 2.0 [32−Bit] SP1 QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 5, 6, 7 AX100
HPQ Proliant: BL40p, DL360(G3)1, DL360(G4)1, DL5601, DL7401, DL760 (G2)1,
DL7601, ML570(G2)1;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
10 Dell PowerEdge: 1800, 2800 Haansoft Asianux PCI, PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP5, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 PCI−X 6, 7 AX100
11 HPQ Proliant: DL1451, DL380(G2)1, DL380(G3)1, DL380(G4)1, DL3801, DL3851, Haansoft Asianux PCI, QLogic FC−AL, EMC Y
DL580(G2)1, DL580(G3)1, DL5851, ML370(G3)1, ML370(G4)1; Server 2.0 [32−Bit] SP1 PCI−X QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 5, 6, 7 AX100
Samsung SS140
1. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
2. Driver/BIOS are available at http://www.qlogic.com
3. Native multipathing is not supported on boot−from−SAN configurations.
4. Based on Asianux 2.0.
5. SNIA HBA API Supported.
6. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
7. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
8. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
9. Driver Version 8.0.16.18 Driver is integrated into the kernel.
10. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Haansoft Asianux Server 2.0 [AMD64]

11/02/2006 7 CLARiiON AX100


CLARiiON AX100

Haansoft Asianux Server 2.0 [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge 6950 Haansoft Asianux Server 2.0 [AMD64] SP1 PCI Express, Emulex LPe111−E1, 2, 3, 4; FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX5, 6 PCI−X QLogic QLE220−E−SP2, 11, 12 FC−SW AX100
2 Sun: x4100, x4200 Haansoft Asianux Server 2.0 [AMD64] SP1 PCI−X Emulex: LP1050−E1, 2, 4, 13, FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX5, 6 LP982−E1, 2, 4; FC−SW AX100
QLogic QLA2340−E−SP2, 7, 8
3 HPQ Proliant: DL14510, Haansoft Asianux Server 2.0 [AMD64] SP1 PCI, PCI−X QLogic QLE220−E−SP2, 9, 11, 12 FC−AL, EMC CLARiiON Y
DL38510, DL58510 v2.6.9−34.21AX5, 6 FC−SW AX100
1. Driver Version 8.0.16.18 Driver is integrated into the kernel.
2. SNIA HBA API Supported.
3. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Native multipathing is not supported on boot−from−SAN configurations.
6. Based on Asianux 2.0.
7. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
8. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver/BIOS are available at http://www.qlogic.com
10. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
11. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
12. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
13. Firmware Version 1.91a5

Haansoft Asianux Server 2.0 [EM64T]

Haansoft Asianux Server 2.0 [EM64T]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, Haansoft Asianux Server 2.0 [EM64T] PCI Express Emulex LPe111−E3, FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX1, 2 4, 5, 6 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
2 Dell PowerEdge 1950 Haansoft Asianux Server 2.0 [EM64T] PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 7, 8 FC−SW CLARiiON
AX100
3 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux Server 2.0 [EM64T] PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 7, 8, FC−SW CLARiiON
10 AX100
4 Dell PowerEdge: 2900, 2950; Haansoft Asianux Server 2.0 [EM64T] PCI Express, Emulex LPe111−E3, FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 PCI−X 4, 5, 6 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
5 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, Haansoft Asianux Server 2.0 [EM64T] PCI Express, QLogic FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX1, 2 PCI−X QLE220−E−SP3, 7, 8 FC−SW CLARiiON
AX100
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)9 Haansoft Asianux Server 2.0 [EM64T] PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 PCI−X QLE220−E−SP3, 7, 8, FC−SW CLARiiON
10 AX100
7 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux Server 2.0 [EM64T] PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 PCI−X11 QLE220−E−SP3, 7, 8, FC−SW CLARiiON
10 AX100
8 Digital Henge SH4500R4; Haansoft Asianux Server 2.0 [EM64T] PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 7, 8, FC−SW CLARiiON
TX300 S2; 10 AX100
HPQ Proliant DL360(G4)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003
9 Dell PowerEdge: 1800, 2800 Haansoft Asianux Server 2.0 [EM64T] PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 Express, PCI−X QLE220−E−SP3, 7, 8 FC−SW CLARiiON
AX100
10 HPQ Proliant DL580(G3)9 Haansoft Asianux Server 2.0 [EM64T] PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 Express, PCI−X QLE220−E−SP3, 7, 8, FC−SW CLARiiON
10 AX100
11 HPQ Proliant: DL380(G4)9, ML370(G4)9 Haansoft Asianux Server 2.0 [EM64T] PCI, PCI−X QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 7, 8, FC−SW CLARiiON
10 AX100
1. Native multipathing is not supported on boot−from−SAN configurations.
2. Based on Asianux 2.0.
3. SNIA HBA API Supported.
4. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
6. Driver Version 8.0.16.18 Driver is integrated into the kernel.
7. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
8. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
9. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Driver/BIOS are available at http://www.qlogic.com

11/02/2006 8 CLARiiON AX100


CLARiiON AX100

11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Microsoft Windows 2000


Where replication of boot LUN is supported, any use of the replicated boot LUN other than in original host may lead to hardware/configuration mismatch that
render the replicated boot LUN unusable. Any issues that arise in trying to use the boot LUN in a host that is non−identical to the source host is outside of the
scope of what EMC can support. Also, in any case due to environment failure where I/O is not written back to the source LUN, or if the source LUN is not left
in a stable state by the source host, the replicated LUN is not guaranteed to be any more usable than the source. Also, there may be specific software
licensing that needs to be investigated when duplicating the boot LUN.

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
1 Unisys: ES7000/510, ES7000/520, ES7000/530, Microsoft PCI Unisys FCH752313−PCX (LP1050)13, 35, FC−AL, EMC Y2
ES7000/540, ES7000/550, ES7000/560 [32−Bit] Windows 2000 58 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
2 Dell PowerEdge 1950; Microsoft PCI Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Samsung: ZSS230, ZSS230D Windows 2000 Express FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
3 Samsung: ZSS230, ZSS230D Microsoft PCI Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC Y2, 3 See17
Windows 2000 Express FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
4 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic QLA2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3 See1
Windows 2000 Express FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
5 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Windows 2000 Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Advanced PCI−X AX100
Server: SP4,
Digital Henge Revo: AS1500, AS1550, AS2500; SP419;
IBM xSeries: x336 (8837)38, x346 (8840)38; Microsoft
Windows 2000
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Server SP4
SR1500/S5000PAL, SR2400/SE7520JR2,
SR2500/S5000PAL, SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
Samsung ZSS132
6 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC Y2, 3 See17
Windows 2000 Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X AX100
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M, Server: SP4,
SR4850HW4/SR6850HW4; SP419;
Lenovo SureServer: R630 G5, R650, R650 G5, T650 Microsoft
Windows 2000
Server SP4
7 IBM xSeries: x336 (8837)38, x346 (8840)38 Microsoft PCI IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
Windows 2000 Express, FC−SW CLARiiON
Advanced PCI−X AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
8 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic QLA2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3 See1
Windows 2000 Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X AX100
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M, Server: SP4,
SR4850HW4/SR6850HW4; SP419;
Lenovo SureServer: R630 G5, R650, R650 G5, T650 Microsoft
Windows 2000
Server SP4
9 IBM xSeries x3850/x366 (8863)46 Microsoft PCI−X IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2, 25
Windows 2000 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4

11/02/2006 9 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
10 IBM xSeries: x23554, x36054, x365, x44054 Microsoft PCI−X IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
Windows 2000 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
11 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 Emulex: LP1050−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000 LP1150−E10, 13, 14, 16, 33 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
12 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 QLogic QLA2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3 See1
Windows 2000 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
13 IBM xSeries x3800/x260 (8865)46 Microsoft PCI−X47 Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Windows 2000 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
14 IBM xSeries: x3800/x260 (8865)46, x3950/x3950E/x460 Microsoft PCI−X47 IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2, 25
(8872, 8874)46 Windows 2000 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
15 IBM xSeries x3800/x260 (8865)46 Microsoft PCI−X47 IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
Windows 2000 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000:
Datacenter
SP448, Server
SP4
16 Unisys ES7000/460 [32−Bit] Microsoft PCI, Unisys FCH752313−PCX (LP1050)13, 60, FC−AL, EMC Y2
Windows 2000 PCI−X 61 FC−SW CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000:
Datacenter
SP448, Server
SP4
17 IBM Netfinity: 8500, 8500R; Microsoft PCI IBM 19K1246: (QLA2310)4, 5, 6, 7, 39 , FC−AL, EMC Y2
Windows 2000 (QLA2310)4, 5, 6, 7, 39, 49 FC−SW CLARiiON
IBM xSeries x37054 Datacenter AX100
SP448
18 Unisys: ES7000/520, ES7000/530, ES7000/540, Microsoft PCI Unisys FCH752313−PCX (LP1050)13, 35, FC−AL, EMC Y2
ES7000/550 Windows 2000 58 FC−SW CLARiiON
Datacenter AX100
SP448
19 Unisys ES7000/560 [32−Bit] Microsoft PCI Unisys FCH752313−PCX (LP1050)13, 35, FC−AL, EMC Y2
Windows 2000 59 FC−SW CLARiiON
Datacenter AX100
SP448
20 IBM xSeries x44054 Microsoft PCI−X IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
Windows 2000 FC−SW CLARiiON
Datacenter AX100
SP448
21 IBM xSeries x445 (8870) Microsoft PCI, IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
Windows 2000 PCI−X FC−SW CLARiiON
Datacenter AX100
SP448
22 Dell PowerVault: 750N, 755N24, 770N63, 775N Microsoft PCI Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC N See17
Windows 2000 LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
Powered Server AX100
Appliance Kit
SP4 (SAK)
23 Dell PowerVault: 750N, 750N66, 755N24, 755N24, 66, Microsoft PCI Emulex: LP1050−E4, 13, 14, 15, 16 , FC−AL, EMC N See17
770N66, 775N Windows 2000 LP1150−E10, 13, 14, 16, 33 FC−SW CLARiiON
Powered Server AX100
Appliance Kit
SP4 (SAK)

11/02/2006 10 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
24 Dell PowerVault: 750N, 755N24, 770N63, 775N Microsoft PCI QLogic: QLA200−E−SP4, 8, 9, FC−AL, EMC N See1
Windows 2000 QLA210−E−SP7, 9, 10, QLA2340−E−SP4, FC−SW CLARiiON
Powered Server 5, 21, QLA2460−E−SP4, 6, 10, 11 AX100
Appliance Kit
SP4 (SAK)
25 Dell PowerEdge 1950 Microsoft PCI QLogic QLA200−E−SP4, 8, 9 FC−AL, EMC N See1
Windows 2000 Express FC−SW CLARiiON
Powered Server AX100
Appliance Kit
SP4 (SAK)
26 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic QLA200−E−SP4, 8, 9 FC−AL, EMC N See1
Windows 2000 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Powered Server PCI−X AX100
Appliance Kit
Intel: SR1500/S5000PAL, SR2500/S5000PAL; SP4 (SAK)
Samsung ZSS132
27 Sun: x4100, x4200 Microsoft PCI−X Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC N See17
Windows 2000 FC−SW CLARiiON
Powered Server AX100
Appliance Kit
SP4 (SAK)
28 Sun: x4100, x4200 Microsoft PCI−X QLogic QLA2460−E−SP4, 6, 10, 11 FC−AL, EMC N See1
Windows 2000 FC−SW CLARiiON
Powered Server AX100
Appliance Kit
SP4 (SAK)
29 IBM xSeries x3800/x260 (8865)46 Microsoft PCI−X47 IBM 19K1246 (QLA2310)4, 5, 6, 7, 39, 49 FC−AL, EMC Y2
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Datacenter
SP448, Server
SP4
30 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, Microsoft PCI Emulex LP101−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
255024, 4300, 4350, 4400, 6100, 6300, 6350, 6400, Windows 2000: FC−SW CLARiiON
6450, 8450; Advanced Server AX100
SP4, Server SP4
HPQ Proliant: DL32012, DL360(G2)12, DL36012,
DL58012, ML350(G2)12, ML35012, ML370(G2)12,
ML37012, ML530(G2)12, ML530(G3)12, ML53012,
ML57012, ML75012;
IBM: Netfinity 4500R, xSeries x225, xSeries x230,
xSeries x232, xSeries x240, xSeries x250, xSeries
x330, xSeries x335, xSeries x340 (4500R), xSeries
x342, xSeries x350 (6000R), xSeries x370
31 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, Microsoft PCI Emulex LP982−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
255024, 4300, 4350, 4400, 6100, 6300, 6350, 6400, Windows 2000: FC−SW CLARiiON
6450, 8450; Advanced Server AX100
SP4, Server SP4
HPQ Proliant: DL32012, DL360(G2)12, DL36012,
DL58012, ML350(G2)12, ML35012, ML370(G2)12,
ML37012, ML530(G2)12, ML530(G3)12, ML53012,
ML57012, ML75012;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335,
x342, x350 (6000R), x370
32 Fuji Serv (ICL) Trimetra Nova; Microsoft PCI Emulex: LP1050−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
HPQ Proliant: 6000R, DL380(G3)12, DL580(G2)12; Windows 2000: LP1150−E10, 13, 14, 16, 33 FC−SW CLARiiON
Advanced Server AX100
IBM xSeries x345 (8670)54 SP4, Server SP4
33 Fujitsu Siemens Primergy: BX60080, BX620 S2F64, Microsoft PCI Fujitsu Siemens BX600−FC22Q4, 5, 6, 7, FC−AL, EMC Y2
BX620 S264, BX62064, BX66064 Windows 2000: 10, 65 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
34 IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20, Microsoft PCI IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
5600, 7000 M1053, 7100, 7600; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
IBM xSeries: x225, x230, x23254, x24054, x25054, SP4, Server SP4
x33054, x335, x340 (4500R)54, x34254, x345 (8670)54,
x350 (6000R)54, x37054
35 IBM Netfinity: 6000R, 8500, 8500R; Microsoft PCI IBM 19K1246 (QLA2310)4, 5, 6, 7, 39, 49 FC−AL, EMC Y2
Windows 2000: FC−SW CLARiiON
IBM xSeries x25554 Advanced Server AX100
SP4, Server SP4
36 IBM: Netfinity 4500R, xSeries x225, xSeries x230, Microsoft PCI IBM: 39M5894 (QLA2460)4, 10, 11, 32 , FC−AL, EMC Y2, 3 See1
xSeries x232, xSeries x240, xSeries x250, xSeries Windows 2000: 39M5895 (QLA2462)4, 10, 11, 32 FC−SW CLARiiON
x330, xSeries x335, xSeries x340 (4500R), xSeries Advanced Server AX100
x342, xSeries x350 (6000R), xSeries x370 SP4, Server SP4
37 HPQ Proliant: DL32012, DL360(G2)12, DL36012, Microsoft PCI QLogic: QLA200−E−SP4, 6, 7, 9, FC−AL, EMC Y2, 3 See1
DL58012, ML350(G2)12, ML35012, ML370(G2)12, Windows 2000: QLA210−E−SP9, 10, 51, FC−SW CLARiiON
ML37012, ML530(G2)12, ML530(G3)12, ML53012, Advanced Server QLA2340−E−SP4, 5, 6, 7, AX100
ML57012, ML75012; SP4, Server SP4 QLA2460−E−SP4, 6, 7, 10, 11
IBM: Netfinity 4500R, xSeries x225, xSeries x230,
xSeries x232, xSeries x240, xSeries x250, xSeries
x330, xSeries x335, xSeries x340 (4500R), xSeries
x342, xSeries x350 (6000R), xSeries x370
38 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, Microsoft PCI QLogic: QLA200−E−SP4, 8, 9, FC−AL, EMC Y2, 3 See1
255024, 4300, 4350, 4400, 6100, 6300, 6350, 6400, Windows 2000: QLA210−E−SP7, 9, 10, QLA2340−E−SP4, FC−SW CLARiiON
6450, 8450 Advanced Server 5, 21, QLA2460−E−SP4, 6, 10, 11 AX100
SP4, Server SP4

11/02/2006 11 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
39 Unisys: ES3120, ES3120L, ES3140, ES3140L Microsoft PCI Unisys FCH752313−PCX (LP1050)13, 35, FC−AL, EMC Y2
Windows 2000: 60 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
40 Samsung: ZSS230, ZSS230D Microsoft PCI Emulex LP101−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
41 Dell PowerEdge 1950; Microsoft PCI Emulex LP982−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Samsung: ZSS230, ZSS230D Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
42 HPQ Proliant: BL460c (404664−B21), BL465c Microsoft PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(403433−B21), BL465c (403434−B21), BL465c Windows 2000: Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407234−B21), BL465c (407235−B21), BL480c Advanced Server (403621−B21)13, 30, 34, QLogic AX100
(404704−B21) SP4, Server SP4 QMH2462 4Gb FC HBA for HP c−Class
Bladesystem (403619−B21)44, 45
43 Dell PowerEdge 1950 Microsoft PCI QLogic QLA200−E−SP4, 6, 7, 9 FC−AL, EMC Y2, 3, 25 See1
Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
44 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y2, 3 See1
Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
45 Dell PowerEdge 1950 Microsoft PCI QLogic: QLA200−E−SP4, 6, 7, 9, FC−AL, EMC Y2, 3 See1
Windows 2000: Express QLA200−E−SP4, 8, 9, QLA210−E−SP7, 9, FC−SW CLARiiON
Advanced Server 10, QLA2340−E−SP4, 5, 21 AX100
SP4, Server SP4
46 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic: QLA2340−E−SP4, 5, 6, 7, FC−AL, EMC Y2, 3, 28 See1
Windows 2000: Express QLA2460−E−SP4, 6, 7, 10, 11 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
47 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI QLogic: QLE220−E−SP4, 10, 40, 41 , FC−AL, EMC Y2, 3, 28 See1
Windows 2000: Express QLE2360−E−SP4, 6, 7, 26, FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Advanced Server QLE2460−E−SP4, 6, 7, 10, 11 AX100
SP4, Server SP4
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS150, ZSS230, ZSS230D
48 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI QLogic: QLE220−E−SP4, 10, 40, 41 , FC−AL, EMC Y2, 3, See1
Windows 2000: Express QLE2360−E−SP4, 6, 7, 26, FC−SW CLARiiON Y2, 3, 25
LangChao: NC3000, NC3500, NF500, NF520; Advanced Server QLE2460−E−SP4, 6, 7, 10, 11 AX100
SP4, Server SP4
Samsung: ZSS230, ZSS230D
49 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Microsoft PCI QLogic: QLE220−E−SP4, 10, 40, 43 , FC−AL, EMC Y2, 3 See1
6850 Windows 2000: Express QLE2360−E−SP4, 21, 26, FC−SW CLARiiON
Advanced Server QLE2460−E−SP4, 10, 11, 21 AX100
SP4, Server SP4
50 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex LP101−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Windows 2000: Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)38, x346 (8840)38; Advanced Server PCI−X AX100
SP4, Server SP4
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2,
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
51 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI Emulex LP982−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Windows 2000: Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Advanced Server PCI−X AX100
SP4, Server SP4
Digital Henge Revo: AS1500, AS1550, AS2500;
IBM xSeries: x336 (8837)38, x346 (8840)38;
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2,
SR1500/S5000PAL, SR2400/SE7520JR2,
SR2500/S5000PAL, SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
Samsung ZSS132
52 HPQ Proliant ML350(G4)12 Microsoft PCI HPQ: AB429A/FC1143 (QLA2460)4, 7, FC−AL, EMC Y2, 3 See1
Windows 2000: Express, 10, 11, AE369A/FC1243 (QLA2462)4, 7, FC−SW CLARiiON
Advanced Server PCI−X 10, 11 AX100
SP4, Server SP4
53 IBM xSeries x346 (8840)38 Microsoft PCI IBM 24P0960 (QLA2340)4, 5, 6, 7, 55 FC−AL, EMC Y
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP4, Server SP4
54 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic QLA200−E−SP4, 6, 7, 9 FC−AL, EMC Y2, 3 See1
Windows 2000: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Advanced Server PCI−X AX100
SP4, Server SP4
IBM xSeries: x336 (8837)38, x346 (8840)38;
Intel: SR1500/S5000PAL, SR2500/S5000PAL;
Samsung ZSS132

11/02/2006 12 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
55 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic QLA200−E−SP4, 6, 7, 9 FC−AL, EMC Y2, 3, 25 See1
Windows 2000: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Advanced Server PCI−X AX100
SP4, Server SP4
Intel: SR1500/S5000PAL, SR2500/S5000PAL;
Samsung ZSS132
56 IBM xSeries: x336 (8837)38, x346 (8840)38 Microsoft PCI QLogic QLA210−E−SP9, 10, 51 FC−AL, EMC Y2, 3 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP4, Server SP4
57 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y2, 3 See1
Windows 2000: Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)38, x346 (8840)38; Advanced Server PCI−X AX100
SP4, Server SP4
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2,
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
58 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic: QLA200−E−SP4, 8, 9, FC−AL, EMC Y2, 3 See1
Windows 2000: Express, QLA210−E−SP7, 9, 10, QLA2340−E−SP4, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Advanced Server PCI−X 5, 21, QLE220−E−SP4, 10, 40, 43 , AX100
SP4, Server SP4 QLE2360−E−SP4, 21, 26,
Intel: SR1500/S5000PAL, SR2500/S5000PAL; QLE2460−E−SP4, 10, 11, 21
Samsung ZSS132
59 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic: QLA2340−E−SP4, 5, 6, 7, FC−AL, EMC Y2, 3, 28 See1
Windows 2000: Express, QLA2460−E−SP4, 6, 7, 10, 11 , FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced Server PCI−X QLE220−E−SP4, 10, 40, 41 , AX100
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M, SP4, Server SP4 QLE2360−E−SP4, 6, 7, 26,
SR4850HW4/SR6850HW4; QLE2460−E−SP4, 6, 7, 10, 11
Lenovo SureServer: R630 G5, R650, R650 G5, T650
60 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic: QLE220−E−SP4, 10, 40, 41 , FC−AL, EMC Y2, 3, See1
Windows 2000: Express, QLE2360−E−SP4, 6, 7, 26, FC−SW CLARiiON Y2, 3, 25
Intel: SR4850HW4−M/SR6850HW4−M, Advanced Server PCI−X QLE2460−E−SP4, 6, 7, 10, 11 AX100
SR4850HW4/SR6850HW4; SP4, Server SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
61 Dell PowerEdge 6850 Microsoft PCI−X Dell 2362M4, 7, 42, 50 FC−AL, EMC Y2
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
62 Dell PowerEdge 1855 Microsoft PCI−X Dell: 2342M4, 5, 7, LPe1105−M10, 13, 34, FC−AL, EMC Y2
Windows 2000: 37, QME24627, 10, 42 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
63 Fujitsu Siemens Primergy: RX200 S2, RX300 S2, Microsoft PCI−X Emulex LP101−E4, 13, 14, 16, 35 FC−AL, EMC Y2, 3 See17
TX200 S2, TX300 S2 Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
64 Dell PowerEdge 265069; Microsoft PCI−X Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Digital Henge INNO: HR−4850, HR−6850; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP4, Server SP4
Samsung ZSS150
65 Dell PowerEdge 265069; Microsoft PCI−X Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC Y2, 3 See17
Digital Henge INNO: HR−4850, HR−6850; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP4, Server SP4
Samsung ZSS150;
Sun: x4100, x4200
66 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, Microsoft PCI−X Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
2800, 2850, 4600, 6600, 6650, 6800, 6850; Windows 2000: LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
Advanced Server AX100
Digital Henge INNO: HR−4850, HR−6850, SH4500; SP4, Server SP4
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12,
DL56012, DL74012, DL760 (G2)12, DL76012,
ML570(G2)12;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
67 IBM xSeries x3850/x366 (8863)46 Microsoft PCI−X Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3, 25 See17
Windows 2000: LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
68 Fujitsu Siemens Primergy: RX300 S2, TX300 S2 Microsoft PCI−X Emulex: LP1050Ex−E4, 10, 13, 14, 16, 35 , FC−AL, EMC Y3, Y3, See17
Windows 2000: LP1050Ex−E4, 10, 13, 14, 34, 35 FC−SW CLARiiON 28
Advanced Server AX100
SP4, Server SP4

11/02/2006 13 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
69 HPQ Proliant DL360(G4)12 Microsoft PCI−X HPQ AE311A/FC1142SR (QLE2460)4, 6, FC−AL, EMC Y2, Y2,
Windows 2000: 7, 10, 11 FC−SW CLARiiON 25, Y2,
Advanced Server AX100 28
SP4, Server SP4
70 HPQ Proliant DL360(G4)12 Microsoft PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 7, FC−AL, EMC Y2, 3 See1
Windows 2000: 10, 11, AE369A/FC1243 (QLA2462)4, 7, FC−SW CLARiiON
Advanced Server 10, 11; AX100
SP4, Server SP4
QLogic: QLE220−E−SP4, 10, 40, 41 ,
QLE2360−E−SP4, 6, 7, 26,
QLE2460−E−SP4, 6, 7, 10, 11
71 HPQ Proliant BL460c: (416653−B21), (416654−B21), Microsoft PCI−X HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(416655−B21), (416656−B21), (432636−B21); Windows 2000: HBA for HP c−Class Bladesystem FC−SW CLARiiON
Advanced Server (403621−B21)13, 30, 34, QLogic AX100
HPQ Proliant BL480c: (416666−B21), (416667−B21), SP4, Server SP4 QMH2462 4Gb FC HBA for HP c−Class
(416668−B21), (416669−B21) Bladesystem (403619−B21)44, 45
72 IBM xSeries: x235, x255, x360, x365, x440 Microsoft PCI−X IBM: 39M5894 (QLA2460)4, 10, 11, 32 , FC−AL, EMC Y2, 3 See1
Windows 2000: 39M5895 (QLA2462)4, 10, 11, 32 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
73 NEC Express 5800: 110Rg−1, 120Rf−1, 120Rh−2 Microsoft PCI−X NEC N8190−120 (LP1050)4, 13, 14, 15, 16, FC−AL, EMC Y
Windows 2000: 62 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
74 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y2, 3, 28 See1
Windows 2000: FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; Advanced Server AX100
SP4, Server SP4
Samsung ZSS150
75 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3, 28 See1
Windows 2000: FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; Advanced Server AX100
SP4, Server SP4
Samsung ZSS150;
Sun: x4100, x4200
76 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, Microsoft PCI−X QLogic QLA2460−E−SP4, 6, 10, 11 FC−AL, EMC Y2, 3 See1
4600, 6600, 6650; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
Sun: x4100, x4200 SP4, Server SP4
77 Digital Henge INNO SH4500; Microsoft PCI−X QLogic: QLA200−E−SP4, 6, 7, 9, FC−AL, EMC Y2, 3 See1
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12, Windows 2000: QLA210−E−SP9, 10, 51 FC−SW CLARiiON
DL56012, DL74012, DL760 (G2)12, DL76012, Advanced Server AX100
ML570(G2)12; SP4, Server SP4
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun: V20z, V40z, x4100, x4200
78 IBM xSeries x3850/x366 (8863)46 Microsoft PCI−X QLogic: QLA200−E−SP4, 6, 7, 9, FC−AL, EMC Y2, 3, 25 See1
Windows 2000: QLA210−E−SP9, 10, 51, FC−SW CLARiiON
Advanced Server QLA2340−E−SP4, 5, 6, 7 AX100
SP4, Server SP4
79 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, Microsoft PCI−X QLogic: QLA200−E−SP4, 8, 9, FC−AL, EMC Y2, 3 See1
2800, 2850, 4600, 6600, 6650, 6800, 6850 Windows 2000: QLA210−E−SP7, 9, 10, QLA2340−E−SP4, FC−SW CLARiiON
Advanced Server 5, 21 AX100
SP4, Server SP4
80 Digital Henge INNO: HR−4850, HR−6850, SH4500; Microsoft PCI−X QLogic: QLA2340−E−SP4, 5, 6, 7, FC−AL, EMC Y2, 3 See1
Windows 2000: QLA2460−E−SP4, 6, 7, 10, 11 FC−SW CLARiiON
Digital Henge SH4500R4; Advanced Server AX100
HPQ Proliant: DL360(G3)12, DL360(G4)12, DL56012, SP4, Server SP4
DL74012, DL760 (G2)12, DL76012, ML570(G2)12;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
81 HPQ Proliant DL360(G4)12 Microsoft PCI−X QLogic: QLE220−E−SP4, 10, 40, 41 , FC−AL, EMC Y2, 3, 25, See1
Windows 2000: QLE2360−E−SP4, 6, 7, 26, FC−SW CLARiiON Y2, 3, 28
Advanced Server QLE2460−E−SP4, 6, 7, 10, 11 AX100
SP4, Server SP4
82 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000: LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
83 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4

11/02/2006 14 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
84 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 QLogic: QLA2340−E−SP4, 5, 6, 7, FC−AL, EMC Y2, 3, 28 See1
Windows 2000: QLA2460−E−SP4, 6, 7, 10, 11 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
85 IBM xSeries x3800/x260 (8865)46 Microsoft PCI−X47 Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3, 25 See17
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
86 IBM xSeries x3800/x260 (8865)46 Microsoft PCI−X47 Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000: LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
87 IBM xSeries: x3800/x260 (8865)46, x3950/x3950E/x460 Microsoft PCI−X47 Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3, 25 See17
(8872, 8874)46 Windows 2000: LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
88 IBM xSeries x3950/x3950E/x460 (8872, 8874)46 Microsoft PCI−X47 Emulex: LP101−E4, 13, 14, 15, 34 , FC−AL, EMC Y3 See17
Windows 2000: LP1050−E4, 13, 14, 15, 16 , LP982−E4, 13, FC−SW CLARiiON
Advanced Server 14, 15, 16 AX100
SP4, Server SP4
89 IBM xSeries x3950/x3950E/x460 (8872, 8874)46 Microsoft PCI−X47 IBM: 19K1246 (QLA2310)4, 5, 6, 7, 39 , FC−AL, EMC Y
Windows 2000: 24P0960 (QLA2340)4, 5, 6, 7, 55 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
90 IBM xSeries x3800/x260 (8865)46 Microsoft PCI−X47 QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
91 IBM xSeries x3950/x3950E/x460 (8872, 8874)46 Microsoft PCI−X47 QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y3 See1
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
92 IBM xSeries: x3800/x260 (8865)46, x3950/x3950E/x460 Microsoft PCI−X47 QLogic QLA2340−E−SP4, 5, 6, 7 FC−AL, EMC Y2, 3, 25 See1
(8872, 8874)46 Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
93 IBM xSeries x3950/x3950E/x460 (8872, 8874)46 Microsoft PCI−X47 QLogic: QLA200−E−SP4, 6, 7, 9, FC−AL, EMC Y2, 3, 25 See1
Windows 2000: QLA210−E−SP9, 10, 51 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
94 Dell PowerEdge 1955 Microsoft PCI, PCI Dell: 2342M4, 5, 7, LPe1105−M10, 13, 34, FC−AL, EMC Y2
Windows 2000: Express, 37, QME24627, 10, 42 FC−SW CLARiiON
Advanced Server PCI−X AX100
SP4, Server SP4
95 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, 7, FC−AL, EMC Y2, 3 See1
Windows 2000: Express, 10, 11, AE369A/FC1243 (QLA2462)4, 7, FC−SW CLARiiON
Advanced Server PCI−X 10, 11; AX100
SP4, Server SP4
QLogic QLA2460−E−SP4, 6, 7, 10, 11
96 HPQ Proliant DL580(G3)12 Microsoft PCI, PCI QLogic QLE220−E−SP4, 10, 40, 41 FC−AL, EMC Y2, 3 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP4, Server SP4
97 HPQ Proliant: DL380(G4)12, DL580(G3)12 Microsoft PCI, PCI QLogic QLE2360−E−SP4, 6, 7, 26 FC−AL, EMC Y2, 3 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP4, Server SP4
98 HPQ Proliant: DL380(G4)12, DL380(G5), DL580(G3)12, Microsoft PCI, PCI QLogic QLE2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3 See1
DL580(G4) Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP4, Server SP4
99 HPQ Proliant: DL380(G5), DL580(G3)12, DL580(G4) Microsoft PCI, PCI QLogic QLE2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3, 25, See1
Windows 2000: Express, FC−SW CLARiiON Y2, 3, 28
Advanced Server PCI−X AX100
SP4, Server SP4
100 HPQ Proliant DL580(G3)12 Microsoft PCI, PCI QLogic: QLE220−E−SP4, 10, 40, 41 , FC−AL, EMC Y2, 3, 25, See1
Windows 2000: Express, QLE2360−E−SP4, 6, 7, 26 FC−SW CLARiiON Y2, 3, 28
Advanced Server PCI−X AX100
SP4, Server SP4
101 Dell PowerEdge: 1800, 1850; Microsoft PCI, Emulex: LP101−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000: PCI−X LP982−E4, 13, 14, 15, 16 FC−SW CLARiiON
HPQ Proliant: DL14512, DL380(G2)12, DL380(G3)12, Advanced Server AX100
DL380(G4)12, DL38012, DL38512, DL580(G2)12, SP4, Server SP4
DL580(G3)12, DL58512, ML350(G3)12, ML370(G3)12,
ML370(G4)12;
IBM: eServer 325 (Model 8835), xSeries x345 (8670),
xSeries x445 (8870);
Samsung SS140
102 IBM xSeries x36054 Microsoft PCI, Emulex: LP1050−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000: PCI−X LP1150−E10, 13, 14, 16, 33 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
103 HPQ Proliant: DL380(G4)12, DL38512, DL58512, Microsoft PCI, HPQ: AB429A/FC1143 (QLA2460)4, 7, FC−AL, EMC Y2, 3 See1
ML370(G4)12 Windows 2000: PCI−X 10, 11, AE369A/FC1243 (QLA2462)4, 7, FC−SW CLARiiON
Advanced Server 10, 11 AX100
SP4, Server SP4

11/02/2006 15 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
104 IBM: eServer 325 (Model 8835), xSeries x445 (8870) Microsoft PCI, IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
Windows 2000: PCI−X FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
105 IBM: eServer 325 (Model 8835), xSeries x345 (8670), Microsoft PCI, IBM: 39M5894 (QLA2460)4, 10, 11, 32 , FC−AL, EMC Y2, 3 See1
xSeries x445 (8870) Windows 2000: PCI−X 39M5895 (QLA2462)4, 10, 11, 32 FC−SW CLARiiON
Advanced Server AX100
SP4, Server SP4
106 HPQ Proliant: DL14512, DL380(G2)12, DL380(G3)12, Microsoft PCI, QLogic: QLA200−E−SP4, 6, 7, 9, FC−AL, EMC Y2, 3 See1
DL380(G4)12, DL38012, DL38512, DL580(G2)12, Windows 2000: PCI−X QLA210−E−SP9, 10, 51, FC−SW CLARiiON
DL580(G3)12, DL58512, ML350(G3)12, ML370(G3)12, Advanced Server QLA2340−E−SP4, 5, 6, 7, AX100
ML370(G4)12; SP4, Server SP4 QLA2460−E−SP4, 6, 7, 10, 11
IBM: eServer 325 (Model 8835), xSeries x345 (8670),
xSeries x445 (8870);
Samsung SS140
107 Dell PowerEdge: 1800, 1850 Microsoft PCI, QLogic: QLA200−E−SP4, 8, 9, FC−AL, EMC Y2, 3 See1
Windows 2000: PCI−X QLA210−E−SP7, 9, 10, QLA2340−E−SP4, FC−SW CLARiiON
Advanced Server 5, 21 AX100
SP4, Server SP4
108 Dell PowerEdge: 155069, 165069, 2300, 240069, Microsoft PCI Emulex: LP1050−E4, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
245069, 250069, 255024, 69, 440069, 6100, 6300, 6350, Windows 2000: LP1150−E10, 13, 14, 16, 33 FC−SW CLARiiON
640069, 645069, 71, 845069; Advanced Server AX100
SP419, Server
HPQ Netserver LC: 2000 U3, 2000r; SP4
HPQ Netserver: LP 2000r, LPR, LT 6000R;
HPQ Proliant: 160012, 185012, 6400R, 800012, 850012,
DL32012, DL360(G2)12, 70, DL36012, DL380(G2)12,
DL380(G3)12, DL38012, DL58012, ML350(G2)12, 72,
ML35012, 72, ML370(G2)12, ML37012, ML530(G2)12,
ML530(G3)12, ML53012, ML57012, ML75012;
IBM Netfinity: 4500R, 8500, 8500R;
IBM xSeries: x225, x230, x23254, x24054, x25054,
x25554, x33054, x335, x340 (4500R)54, x34254, x350
(6000R)54, x37054
109 IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20, Microsoft PCI IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
5600, 6000R, 7000 M1053, 7100, 7600, 8500, 8500R; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
IBM xSeries: x225, x230, x23254, x24054, x25054, SP419, Server
x25554, x33054, x335, x340 (4500R)54, x34254, x350 SP4
(6000R)54, x37054
110 NEC Express 5800: 320La−R75, 320La75, 320Lb−R75, Microsoft PCI NEC N8803−031 (QLA2310F)4, 5, 6, 7, 77, FC−AL, EMC N
79, 320Lb75, 79, 330Ma−R75, 330Mb−R74, 75, 76 , Windows 2000: 78 FC−SW CLARiiON
340Ha−R74, 75, 76 Advanced Server AX100
SP419, Server
SP4
111 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Microsoft PCI Emulex LP1050Ex−E4, 10, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
6850; Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
Digital Henge INNO: HR−4850, HR−6850; SP419, Server
SP4
HPQ Proliant: DL360(G4)12, DL380(G4)12,
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS230, ZSS230D
112 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI Emulex LP1050Ex−E4, 10, 13, 14, 15, 16 FC−AL, EMC Y2, 3, 28 See17
Windows 2000: Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Advanced Server AX100
SP419, Server
HPQ Proliant: DL360(G4)12, DL380(G4)12, SP4
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS150, ZSS230, ZSS230D
113 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, Microsoft PCI Emulex LP1050Ex−E4, 10, 13, 14, 16, 35 FC−AL, EMC Y2, 3, See17
TX600 S2 Windows 2000: Express FC−SW CLARiiON Y2, 3, 28
Advanced Server AX100
SP419, Server
SP4
114 Samsung: ZSS230, ZSS230D Microsoft PCI Emulex LP982−E4, 10, 13, 14, 15, 16, 36 FC−AL, EMC Y2, 3 See17
Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
115 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Microsoft PCI Emulex: LPe111−E4, 10, 13, 29, 30, 31 , FC−AL, EMC Y2, 3 See17
6850; Windows 2000: Express LPe1150−E10, 13, 14, 16, 37 FC−SW CLARiiON
Advanced Server AX100
Digital Henge INNO: HR−4850, HR−6850; SP419, Server
SP4
HPQ Proliant: DL360(G4)12, 52, DL380(G4)12,
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS230, ZSS230D
116 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI Emulex: LPe111−E4, 10, 13, 29, 30, 31 , FC−AL, EMC Y2, 3, 28 See17
Windows 2000: Express LPe1150−E10, 13, 14, 16, 37 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Advanced Server AX100
SP419, Server
HPQ Proliant: DL360(G4)12, 52, DL380(G4)12, SP4
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS150, ZSS230, ZSS230D

11/02/2006 16 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
117 HPQ Proliant DL360(G4)12 Microsoft PCI HPQ A7560A (LP1050Ex)4, 10, 13, 14, 16 FC−AL, EMC Y2, Y2,
Windows 2000: Express FC−SW CLARiiON 28
Advanced Server AX100
SP419, Server
SP4
118 HPQ Proliant: DL360(G4)12, 52, DL380(G4)12, Microsoft PCI HPQ A8002A/FC2142SR (LPe1150)10, FC−AL, EMC Y2, Y2,
DL580(G3)12 Windows 2000: Express 13, 14, 16, 37 FC−SW CLARiiON 28
Advanced Server AX100
SP419, Server
SP4
119 HPQ Proliant: DL360(G4)12, DL360(G4)12, 52, Microsoft PCI HPQ AE311A/FC1142SR (QLE2460)4, 6, FC−AL, EMC Y2, Y2,
DL380(G4)12 Windows 2000: Express 7, 10, 11 FC−SW CLARiiON 28
Advanced Server AX100
19
SP4 , Server
SP4
120 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic QLA2340−E−SP4, 5, 6, 7, 20 FC−AL, EMC Y2, 3 See1
Windows 2000: Express FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
121 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex LP982−E4, 10, 13, 14, 15, 16, 36 FC−AL, EMC Y2, 3 See17
Windows 2000: Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced Server PCI−X AX100
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M, SP419, Server
SR4850HW4/SR6850HW4; SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
122 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI Emulex: LP1050Ex−E4, 10, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000: Express, LPe111−E4, 10, 13, 29, 30, 31 , FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Advanced Server PCI−X LPe1150−E10, 13, 14, 16, 37 AX100
SP419, Server
Digital Henge Revo: AS1500, AS1550, AS2500; SP4
Intel: SR1500/S5000PAL, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
Samsung ZSS132
123 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex: LP1050Ex−E4, 10, 13, 14, 15, 16 , FC−AL, EMC Y2, 3, 28 See17
Windows 2000: Express, LPe111−E4, 10, 13, 29, 30, 31 , FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced Server PCI−X LPe1150−E10, 13, 14, 16, 37 AX100
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M, SP419, Server
SR4850HW4/SR6850HW4; SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
124 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic QLA2340−E−SP4, 5, 6, 7, 20 FC−AL, EMC Y2, 3 See1
Windows 2000: Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced Server PCI−X AX100
SR2400/SE7520JR2, SR4850HW4−M/SR6850HW4−M, SP419, Server
SR4850HW4/SR6850HW4; SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
125 Dell PowerEdge: 1600SC, 1750, 260069, 2650, 2800, Microsoft PCI−X Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
2850, 460069, 660069, 665069, 6800, 6850; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
Digital Henge INNO: HR−4850, HR−6850, SH4500; SP419, Server
SP4
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12,
DL56012, DL74012, DL760 (G2)12, DL76012,
ML570(G2)12;
IBM xSeries: x23554, x36054, x365, x440, x44054;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
126 IBM xSeries x3850/x366 (8863)46 Microsoft PCI−X Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3, 25 See17
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
127 HPQ Proliant DL360(G4)12 Microsoft PCI−X Emulex LP1050Ex−E4, 10, 13, 14, 15, 16 FC−AL, EMC Y2, 3, See17
Windows 2000: FC−SW CLARiiON Y2, 3, 28
Advanced Server AX100
SP419, Server
SP4

11/02/2006 17 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
128 Dell PowerEdge: 1600SC, 1750, 260069, 2650, 460069, Microsoft PCI−X Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC Y2, 3 See17
660069, 665069; Windows 2000: FC−SW CLARiiON
Advanced Server AX100
Digital Henge INNO: HR−4850, HR−6850, SH4500; SP419, Server
SP4
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12, 52,
DL56012, DL74012, DL760 (G2)12, DL76012,
ML570(G2)12;
IBM xSeries: x23554, x36054, x365, x440, x44054;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
129 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X Emulex LP982−E4, 10, 13, 14, 15, 16, 36 FC−AL, EMC Y2, 3 See17
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP419, Server
SP4
Samsung ZSS150
130 HPQ Proliant DL360(G4)12, 52 Microsoft PCI−X Emulex: LPe111−E4, 10, 13, 29, 30, 31 , FC−AL, EMC Y2, 3, See17
Windows 2000: LPe1150−E10, 13, 14, 16, 37 FC−SW CLARiiON Y2, 3, 28
Advanced Server AX100
SP419, Server
SP4
131 HPQ Proliant DL360(G4)12, 52 Microsoft PCI−X HPQ A8002A/FC2142SR (LPe1150)10, FC−AL, EMC Y2, Y2,
Windows 2000: 13, 14, 16, 37 FC−SW CLARiiON 28
Advanced Server AX100
SP419, Server
SP4
132 HPQ Proliant: DL360(G4)12, DL360(G4)12, 52 Microsoft PCI−X HPQ AE311A/FC1142SR (QLE2460)4, 6, FC−AL, EMC Y2, Y2,
Windows 2000: 7, 10, 11 FC−SW CLARiiON 28
Advanced Server AX100
SP419, Server
SP4
133 HPQ Proliant BL45p Microsoft PCI−X HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL25p/BL45p FC−SW CLARiiON
Advanced Server 381881−B214, 6, 7, 10, 73 , Emulex−based AX100
SP419, Server BL25/30/35/45p Fibre Channel
SP4 Mezzanine HBA − 394588−B214, 13, 14,
16, 56

134 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2340−E−SP4, 5, 6, 7, 20 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP419, Server
SP4
Samsung ZSS150
135 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2460−E−SP4, 6, 7, 10, 11 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced Server AX100
LangChao: NC3000, NC3500, NF500, NF520; SP419, Server
SP4
Samsung ZSS150;
Sun: x4100, x4200
136 HPQ Proliant BL20p (G2) Microsoft PCI−X23 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL20p (G2) FC−SW CLARiiON
Advanced Server 300874−B214, 6, 7, 22 AX100
SP419, Server
SP4
137 HPQ Proliant BL20p: (G3), (G4) Microsoft PCI−X23 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL20p (G3) FC−SW CLARiiON
Advanced Server 361426−B214, 6, 7, 22, Emulex−based AX100
SP419, Server BL20p (G3) Fibre Channel Mezzanine
SP4 HBA − 394757−B214, 13, 14, 16, 56
138 HPQ Proliant BL25p Microsoft PCI−X23 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
Windows 2000: for HP Proliant BL25p/BL45p FC−SW CLARiiON
Advanced Server 381881−B214, 6, 7, 10, 73 , Emulex−based AX100
SP419, Server BL25/30/35/45p Fibre Channel
SP4 Mezzanine HBA − 394588−B214, 13, 14,
16, 56

139 HPQ Proliant BL30p Microsoft PCI−X23 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2, 57
Windows 2000: for HP Proliant BL30p/BL35p FC−SW CLARiiON
Advanced Server 354054−B214, 6, 7, 22, Emulex−based AX100
SP419, Server BL25/30/35/45p Fibre Channel
SP4 Mezzanine HBA − 394588−B214, 13, 14,
16, 56

140 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 Emulex LP982−E4, 10, 13, 14, 15, 16, 36 FC−AL, EMC Y2, 3 See17
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
141 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X27 QLogic QLA2340−E−SP4, 5, 6, 7, 20 FC−AL, EMC Y2, 3 See1
Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4

11/02/2006 18 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
142 IBM xSeries: x3800/x260 (8865)46, x3950/x3950E/x460 Microsoft PCI−X47 Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3, 25 See17
(8872, 8874)46 Windows 2000: FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
143 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC Y2, 3 See17
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP419, Server
SP4
144 HPQ Proliant: DL380(G4)12, DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LPe1150−E10, 13, 14, 16, 37 FC−AL, EMC Y2, 3 See17
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
19
SP4 , Server
SP4
145 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LPe1150−E10, 13, 14, 16, 37 FC−AL, EMC Y2, 3, 28 See17
Windows 2000: Express, FC−SW CLARiiON
Advanced Server PCI−X AX100
SP419, Server
SP4
146 HPQ Proliant DL380(G4)12 Microsoft PCI, PCI Emulex: LP1050Ex−E4, 10, 13, 14, 15, 16 , FC−AL, EMC Y2, 3 See17
Windows 2000: Express, LPe111−E4, 10, 13, 29, 30, 31 FC−SW CLARiiON
Advanced Server PCI−X AX100
SP419, Server
SP4
147 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)10, FC−AL, EMC Y2, Y2,
Windows 2000: Express, 13, 14, 16, 37 , AE311A/FC1142SR FC−SW CLARiiON 28
Advanced Server PCI−X (QLE2460)4, 6, 7, 10, 11 AX100
SP419, Server
SP4
148 Dell PowerEdge: 1800, 1850; Microsoft PCI, Emulex LP1050−E4, 13, 14, 15, 16 FC−AL, EMC Y2, 3 See17
Windows 2000: PCI−X FC−SW CLARiiON
HPQ Proliant: DL14512, DL380(G4)12, DL38512, Advanced Server AX100
DL580(G2)12, DL580(G3)12, DL58512, ML350(G3)12, SP419, Server
ML370(G3)12, ML370(G4)12; SP4
IBM: eServer 325 (Model 8835), xSeries x345 (8670)54,
xSeries x445 (8870);
Samsung SS140
149 HPQ Proliant: DL14512, DL380(G4)12, DL38512, Microsoft PCI, Emulex LP1150−E10, 13, 14, 16, 33 FC−AL, EMC Y2, 3 See17
DL580(G2)12, DL580(G3)12, DL58512, ML350(G3)12, Windows 2000: PCI−X FC−SW CLARiiON
ML370(G3)12, ML370(G4)12; Advanced Server AX100
19
SP4 , Server
IBM: eServer 325 (Model 8835), xSeries x345 (8670)54, SP4
xSeries x445 (8870);
Samsung SS140
150 IBM: eServer 325 (Model 8835), xSeries x345 (8670)54, Microsoft PCI, IBM 19K1246 (QLA2310)4, 5, 6, 7, 39 FC−AL, EMC Y2
xSeries x445 (8870) Windows 2000: PCI−X FC−SW CLARiiON
Advanced Server AX100
SP419, Server
SP4
151 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 3 See1
Windows 2000 Express AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
152 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 3 See17
Windows 2000 Express AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
153 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3 See1
Windows 2000 Express, Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX100
SR4850HW4/SR6850HW4; Server: SP4,
SP419;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
Microsoft
Windows 2000
Server SP4
154 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3 See17
Windows 2000 Express, Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX100
SR4850HW4/SR6850HW4; Server: SP4,
SP419;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
Microsoft
Windows 2000
Server SP4
155 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3 See1
Windows 2000 Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4

11/02/2006 19 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
156 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3 See17
Windows 2000 Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced AX100
Server: SP4,
SP419;
Microsoft
Windows 2000
Server SP4
157 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, See1
Windows 2000: Express Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON Y2, 3, 25,
Advanced Server AX100 Y2, 3, 28
SP4, Server SP4
158 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 3, 25, See1
Windows 2000: Express AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON Y2, 3, 28
Advanced Server AX100
SP4, Server SP4
159 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, 25, See1
Windows 2000: Express, Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON Y2, 3, 28
Intel: SR4850HW4−M/SR6850HW4−M, Advanced Server PCI−X AX100
SR4850HW4/SR6850HW4; SP4, Server SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
160 Bull NovaScale: 2021, 2040, 2320 Microsoft PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
Windows 2000: port for NovaScale Blade Series CLARiiON
Advanced Server CFSN202−11004, 6, 7, 18 AX100
SP4, Server SP4
161 Bull NovaScale: 2021, 2320 Microsoft PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
Windows 2000: port mini for NovaScale Blade 2021 CLARiiON
Advanced Server CFSN202−21004, 6, 7, 18, SBEFCM AX100
SP4, Server SP4 (SFF) Mezzanine HBA4, 6, 7, 10, 18 ,
SBEFCM4 (SFF) 4Gb Mezzanine HBA4,
7, 10, 67, 68

162 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, 28 See1
Windows 2000: Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced Server AX100
SP4, Server SP4
163 Intel SBXD62 Blade Server Microsoft PCI−X Intel: SBEFCM (SFF) Mezzanine HBA4, FC−SW EMC Y
Windows 2000: 6, 7, 10, 18 , SBEFCM4 (SFF) 4Gb CLARiiON
Advanced Server Mezzanine HBA4, 7, 10, 67, 68 AX100
SP4, Server SP4
164 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, See17
Windows 2000: Express Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON Y2, 3, 28
Advanced Server AX100
SP419, Server
SP4
165 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 3, 28 See17
Windows 2000: Express AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Advanced Server AX100
SP419, Server
SP4
166 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 3, 28 See17
Windows 2000: Express, Module AHWFCMOD4, 6, 7, 10, 42, 50 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced Server PCI−X AX100
SR4850HW4/SR6850HW4; SP419, Server
SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
1. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
2. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
3. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
4. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
5. BIOS 1.47
6. Driver Version 9.1.2.10
7. Driver Version 9.1.2.11
8. Driver Version 9.1.2.10 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
9. BIOS 1.23
10. SNIA HBA API Supported.
11. BIOS 1.08
12. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
13. BIOS 1.70a3
14. Driver Version 2.41a1 SCSI FC Port driver
15. Firmware Version 1.91a5
16. Driver Version 2.40a3 SCSI FC Port driver
17. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
18. BIOS 1.43
19. Windows 2000 hosts running less than SP4 could be susceptible to data loss during LUN expansion operations. This issue is corrected by Microsoft in SP4, or by applying hotfix
327020. See EMC Solution IS emc73538 and Microsoft Knowledge Base article 327020 for more information.
20. PowerPath supported. ATF/CDE not supported.
21. Driver Version 9.1.2.11 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
22. BIOS 1.45
23. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
24. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
25. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar SCSI.)
26. BIOS 1.05
27. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
28. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
29. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions.
30. Firmware Version 2.50a8
31. Driver Version 2.41a1 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or

11/02/2006 20 CLARiiON AX100


CLARiiON AX100

HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions.
32. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
33. Firmware Version 2.10a10
34. Driver Version 2.40a3
35. Firmware Version 1.91a1
36. The Emulex LP9XXX HBA family requires a host PCI bus capable of supplying 3.3 VDC bus power. The PCI slot can use either 3.3 VDC or 5.0 VDC signaling interfaces.
37. Firmware Version 2.50a6
38. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
39. This HBA is equivalent to the QLogic QLA2310.
40. BIOS 1.02
41. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
42. BIOS 1.06
43. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
44. Driver Version 9.1.2.14
45. BIOS 1.16
46. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
47. Accepts PCI−X 1.0 and 2.0 HBAs.
48. Update Rollup 1 for Windows 2000 SP4 is supported. For more information on this Rollup and to download the necessary software, please see
http://support.microsoft.com/default.aspx?scid=kb;en−us;891861
49. Host must be offline for interfamily Symmetrix microcode upgrade.
50. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
51. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons.
52. Proliant DL360 G4 servers with a BIOS prior to P52 may not be running a fully ACPI−compliant BIOS. Emulex 4gb HBAs require the latest ACPI−compliant BIOS and your server may
require Windows 2000 to be reinstalled. You do not need to reinstall Windows 2000 if you had an ACPI−compliant BIOS and then upgraded to a newer ACPI−compliant BIOS. You only
need to reinstall Windows 2000 if you did not have an ACPI BIOS or an ACPI−compliant BIOS before you upgraded the BIOS. Refer to Microsoft knowledge base article 256841 for
more information. (http://support.microsoft.com/?kbid=256841&sd=RMVP)
53. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
54. For IBM xSeries Servers running Windows 2000 with IBM ServerRaid controller 4M, the ServerRaid Driver must be 6.00 or above for use with EMC PowerPath 3.0 and above. IBM
driver can be downloaded at:
http://www−3.ibm.com/pc/support/site.wss/document.do?lndocid=MIGR−39723
55. This HBA is equivalent to the QLogic QLA2340.
56. Firmware Version 1.91a2
57. For external boot configurations running EMC Powerpath on Windows 2000, HP Proliant BL30p & BL35p require a minimum of Powerpath version 4.4.1.
58. Driver Version 2.30a2 SCSI FC Port driver
59. Driver Version 2.21a0
60. Driver Version 2.22a8
61. Firmware Version 1.90a4
62. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
63. For AX100 configurations, only Dell PowerVault systems with dual CPUs are supported.
64. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
65. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
66. Not supported with Emulex LP8000−EMC HBA.
67. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Requires Microsoft STORPort hotfix Q903081. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];903081 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
68. BIOS 1.12
69. If using Dell PERC Controller, requires PERC 2 or PERC 3 with OpenManager 3.0 and Array Manager 3.1. The afamgt.sys must be version 2.6.0.3486 (or above).
70. Requires minimum BIOS v4.01 rev A (5/17/2002) for use with Emulex HBAs.
71. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
72. HPQ Proliant ML350 (1GHz) : D04,F04 (11/13/2000) , HPQ Proliant ML350(600,733,800,866,933 MHz) : D02, F04 (11/13/2000).
73. BIOS 1.48
74. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
75. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
76. Supports Stratus OS 1.3.X through 2.1.X.
77. QLogic SANSurfer/SANBlade Manager is not supported. Use QLogic SANCLI utility.
78. QLogic SanBlade Manager is not supported.
79. Supports Stratus OS 2.0.X through 2.1.X.
80. BX600 uses an embedded fibre channel controller. Contact Fujitsu Siemens to acquire proper BIOS for embedded fibre channel controller.

Microsoft Windows 2003 [x64]

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
1 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y6
BL465c (403433−B21), BL465c [x64] Enterprise: Edition, Express HP c−Class Bladesystem (403621−B21)1, FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), Edition R212 37, 38 AX100
BL465c (407235−B21), BL480c
(404704−B21)
2 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
BL465c (403433−B21), BL465c [x64] Enterprise: Edition, Express HP c−Class Bladesystem (403619−B21)35, FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), Edition R212 51 AX100
BL465c (407235−B21), BL480c
(404704−B21)

11/02/2006 21 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
3 Fujitsu Siemens Primergy BX620: S2F58, Microsoft Windows 2003 PCI Emulex LP1050−E1, 5, 11, 57 FC−AL, EMC Y6, 8 See9
S258; [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Fujitsu Siemens Primergy BX630: (2−way),
(4−way) Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
4 Fujitsu Siemens Primergy BX620: S2F58, Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q3, 20, 27, 28 FC−AL, EMC Y6
S258, S3; [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Fujitsu Siemens Primergy BX630: (2−way),
(4−way), (8−way) Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
5 Fujitsu Siemens Primergy: RX200 S2, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E1, 3, 5, 11, 57 FC−AL, EMC Y6, 7, 8, See9
S2, TX600 S2 [x64] Enterprise: Edition, Express FC−SW CLARiiON Y6, 8
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
6 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex LP1150−E1, 3, 4, 5, 11, 22 FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
7 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI Emulex LPe111−E1, 3, 4, 11, 37 FC−AL, EMC Y6, 7, 8 See9
6850; [x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
Fujitsu Siemens Primergy RX300 S3; [x64] Standard: Edition,
HPQ Proliant: DL360(G4)10, DL380(G4)10, Edition R212
DL580(G3)10;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
8 Dell PowerEdge: 1850, 1950, 2800; Microsoft Windows 2003 PCI Emulex LPe111−E1, 3, 4, 11, 37 FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; Edition R212; AX100
Digital Henge Revo: JS1400, JS2400; Microsoft Windows 2003
[x64] Standard: Edition,
Fujitsu Siemens Primergy RX300 S3; Edition R212
HPQ Proliant: DL360(G4)10, DL380(G4)10,
DL580(G3)10;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
9 Fujitsu Siemens Primergy RX300 S3 Microsoft Windows 2003 PCI Emulex LPe1150−E1, 3, 5, 11, 59 FC−AL, EMC Y6, 7, 8, See9
[x64] Enterprise: Edition, Express FC−SW CLARiiON Y6, 8
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
10 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex: LP1050−E1, 2, 4, 5, 11 , LP1150−E1, FC−AL, EMC Y6, 8, 31 See9
[x64] Enterprise: Edition, Express 3, 4, 5, 11, 22 , LP982−E1, 2, 4, 5, 11 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
11 Dell PowerEdge 1950; Microsoft Windows 2003 PCI Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8 See9
Samsung: ZSS230, ZSS230D [x64] Enterprise: Edition, Express 4, 5, 11 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
12 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 11 , FC−AL, EMC Y6, 7, 8 See9
6850 [x64] Enterprise: Edition, Express LPe1150−E1, 3, 4, 11, 21 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
13 Dell PowerEdge: 1850, 1950, 2800 Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 11 , FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express LPe1150−E1, 3, 4, 11, 21 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
14 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 5, 11 , FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express LPe1150−E1, 3, 4, 5, 11, 21 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Edition R212; AX100
HPQ Proliant: DL360(G4)10, DL380(G4)10, Microsoft Windows 2003
DL580(G3)10; [x64] Standard: Edition,
Edition R212
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D

11/02/2006 22 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
15 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 5, 11 , FC−AL, EMC Y6, 7, 8 See9
[x64] Enterprise: Edition, Express LPe1150−E1, 3, 4, 5, 11, 21 FC−SW CLARiiON
HPQ Proliant: DL360(G4)10, DL380(G4)10, Edition R212; AX100
DL580(G3)10;
Microsoft Windows 2003
IBM xSeries x3455 (7984); [x64] Standard: Edition,
LangChao: NC3000, NC3500, NF500, Edition R212
NF520;
Samsung: ZSS230, ZSS230D
16 HPQ Proliant DL360(G4)10 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)1, 3, 4, 5, 11 FC−AL, EMC Y6, Y6, 7
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
17 HPQ Proliant: DL360(G4)10, DL380(G4)10, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)1, 3, 4, FC−AL, EMC Y6, Y6, 7
DL580(G3)10 [x64] Enterprise: Edition, Express 5, 21 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
18 HPQ Proliant: DL360(G4)10, DL380(G4)10 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)3, 11, FC−AL, EMC Y6, Y6, 7
[x64] Enterprise: Edition, Express 14, 15, 17 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
19 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)1, 19, 21, 38, 52 FC−AL, EMC Y6, 8 See9
120Ri−2 [x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
20 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)1, 19, 21, 38, 52 FC−AL, EMC Y6, 8, 53 See9, 13
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
21 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA2340−E−SP11, 15, 20 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
22 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP3, 11, 35, 36 FC−AL, EMC Y6, 7, 8 See13
6850; [x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R212; AX100
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
IBM xSeries x3455 (7984); [x64] Standard: Edition,
LangChao: NC3000, NC3500, NF500, Edition R212
NF520;
Samsung: ZSS230, ZSS230D
23 Dell PowerEdge: 1850, 1950, 2800; Microsoft Windows 2003 PCI QLogic QLE220−E−SP3, 11, 35, 36 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; Edition R212; AX100
Digital Henge Revo: JS1400, JS2400; Microsoft Windows 2003
[x64] Standard: Edition,
IBM xSeries x3455 (7984); Edition R212
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
24 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP11, 15, 17, 20 , FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express QLA2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
25 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP3, 11, 35, 36 , FC−AL, EMC Y6, 8, 31 See13
[x64] Enterprise: Edition, Express QLE2360−E−SP11, 15, 17, 23 , FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Edition R212; QLE2460−E−SP3, 11, 14, 15, 17 AX100
NF520;
Microsoft Windows 2003
Samsung: ZSS230, ZSS230D [x64] Standard: Edition,
Edition R212
26 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP11, 15, 17, 23 , FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express QLE2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Edition R212; AX100
IBM xSeries x3455 (7984); Microsoft Windows 2003
LangChao: NC3000, NC3500, NF500, [x64] Standard: Edition,
NF520; Edition R212
Samsung: ZSS150, ZSS230, ZSS230D

11/02/2006 23 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
27 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP11, 15, 17, 23 , FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express QLE2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
IBM xSeries x3455 (7984); Edition R212; AX100
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung: ZSS230, ZSS230D Edition R212
28 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP11, 15, 23, FC−AL, EMC Y6, 7, 8 See13
6850 [x64] Enterprise: Edition, Express QLE2460−E−SP3, 11, 14, 15 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
29 Dell PowerEdge: 1850, 1950, 2800 Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP11, 15, 23, FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express QLE2460−E−SP3, 11, 14, 15 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
30 IBM: eServer 326m (Model 7969), xSeries Microsoft Windows 2003 PCI Emulex LP1050Ex−E1, 2, 3, 5, 11 FC−AL, EMC Y6, 7, 8, See9
x3550 (7978), xSeries x3650 (7979), xSeries [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y6, 8
x3755 (8877) Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
31 Fujitsu Siemens Primergy: RX220, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E1, 3, 5, 11, 57 FC−AL, EMC Y6, 7, 8, See9
S3, TX600 S3 [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y6, 8
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
32 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LP1150−E1, 3, 4, 5, 11, 22 FC−AL, EMC Y6, 8, See9
[x64] Enterprise: Edition, Express, FC−SW CLARiiON Y6, 8, 31
Intel: SC5300AF2, SE7520BB2, 12
Edition R2 ; PCI−X AX100
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M, Microsoft Windows 2003
SR4850HW4/SR6850HW4; [x64] Standard: Edition,
Edition R212
Lenovo SureServer: R630 G5, R650, R650
G5, T650
33 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E1, 3, 4, 11, 37 FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Digital Henge INNO: HR−4850T, HR−6850T; Edition R2 ; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R212
Fujitsu Siemens Primergy: RX200 S3,
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
34 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E1, 3, 4, 11, 37 FC−AL, EMC Y6, 7, 8 See9
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Edition R212; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R212
Fujitsu Siemens Primergy: RX200 S3,
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
35 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex LPe1150−E1, 3, 5, 11, 21 FC−AL, EMC Y6, 7, 8 See9
x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Edition R2 ; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212

11/02/2006 24 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
36 Fujitsu Siemens Primergy: RX200 S3, Microsoft Windows 2003 PCI Emulex LPe1150−E1, 3, 5, 11, 59 FC−AL, EMC Y6, 7, 8, See9
RX220, RX600 S3, TX300 S3, TX600 S3 [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y6, 8
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
37 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express, 4, 5, 11 FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Edition R212; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R212
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
38 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8, 31 See9
[x64] Enterprise: Edition, Express, 4, 5, 11 FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Edition R212; PCI−X AX100
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x64] Standard: Edition,
SR1400/SE7520JR2, SR2400/SE7520JR2, Edition R212
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
39 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP1050−E1, 2, 5, 11, LP1150−E1, 3, FC−AL, EMC Y6, 8 See9
x3755 (8877) [x64] Enterprise: Edition, Express, 5, 11, 22, LP982−E1, 2, 5, 11, LPe1150−E1, 3, FC−SW CLARiiON
12
Edition R2 ; PCI−X 5, 11, 21 AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
40 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 11 , FC−AL, EMC Y6, 7, 8, See9
[x64] Enterprise: Edition, Express, LPe1150−E1, 3, 4, 11, 21 FC−SW CLARiiON Y6, 8
Digital Henge Revo: AS1500, AS1550, 12
Edition R2 ; PCI−X AX100
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x64] Standard: Edition,
SR2500/S5000PAL; Edition R212
Samsung ZSS132
41 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 5, 11 , FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express, LPe1150−E1, 3, 4, 5, 11, 21 FC−SW CLARiiON
IBM eServer 326m (Model 7969); 12
Edition R2 ; PCI−X AX100
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x64] Standard: Edition,
SR4850HW4/SR6850HW4; Edition R212
Lenovo SureServer: R630 G5, R650, R650
G5, T650
42 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E1, 2, 3, 4, 5, 11 , FC−AL, EMC Y6, 7, 8 See9
[x64] Enterprise: Edition, Express, LPe1150−E1, 3, 4, 5, 11, 21 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Edition R212; PCI−X AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x64] Standard: Edition,
Lenovo SureServer: R630 G5, R650, R650 Edition R212
G5, T650
43 HPQ Proliant ML350(G4)10 Microsoft Windows 2003 PCI HPQ: AB429A/FC1143 (QLA2460)3, 11, 14, FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, 15, AE369A/FC1243 (QLA2462)3, 11, 14, 15 FC−SW CLARiiON
12
Edition R2 ; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
44 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)11, 15, 17, 20, 32 FC−AL, EMC Y6, 31
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Edition R2 ; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
45 IBM xSeries: x346 (8840)67, x3550 (7978), Microsoft Windows 2003 PCI IBM 24P0960 (QLA2340)11, 15, 17, 20, 43 FC−AL, EMC Y6
x3650 (7979) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Edition R2 ; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
46 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)3, 11, 15, 17, 20 FC−AL, EMC N, Y6, 7, See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON 8, Y6, 8,
12
Edition R2 ; PCI−X AX100 Y6, 8, 31
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212

11/02/2006 25 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
47 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)3, 11, 15, 17, 20 FC−AL, EMC Y6, 7, 8, See9
[x64] Enterprise: Edition, Express, FC−SW CLARiiON Y6, 8,
Edition R212; PCI−X AX100 Y6, 8, 31
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
48 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM: 19K1246 (QLA2310)11, 15, 17, 20, 32 , FC−AL, EMC Y6
[x64] Enterprise: Edition, Express, 24P8053 (QLA2342)3, 11, 15, 17, 20 FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
49 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)3, 11, 14, 60 , FC−AL, EMC Y6, 8 See13
x3755 (8877) [x64] Enterprise: Edition, Express, 39M5895 (QLA2462)3, 11, 14, 60 ; FC−SW CLARiiON
Edition R212; PCI−X AX100
QLogic: QLA2340−E−SP11, 17, 20,
Microsoft Windows 2003 QLA2460−E−SP3, 11, 14, 17 ,
[x64] Standard: Edition, QLE2460−E−SP3, 11, 14, 17
Edition R212
50 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2340−E−SP11, 15, 17, 20 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Edition R212; PCI−X AX100
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x64] Standard: Edition,
SR1400/SE7520JR2, SR2400/SE7520JR2, Edition R212
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
51 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic QLA2340−E−SP11, 15, 17, 20 FC−AL, EMC Y6, 8, 31 See13
x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Edition R2 ; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
52 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2460−E−SP3, 11, 14, 15, 17 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, 12
Edition R2 ; PCI−X AX100
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M, Microsoft Windows 2003
SR4850HW4/SR6850HW4; [x64] Standard: Edition,
Edition R212
Lenovo SureServer: R630 G5, R650, R650
G5, T650
53 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP3, 11, 35, 36 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Digital Henge INNO: HR−4850T, HR−6850T; Edition R2 ; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R212
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
54 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP3, 11, 35, 36 FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Edition R212; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R212
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
55 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE2360−E−SP11, 15, 23 FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Edition R212; PCI−X AX100
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x64] Standard: Edition,
SR2500/S5000PAL; Edition R212
Samsung ZSS132

11/02/2006 26 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
56 IBM xSeries: x346 (8840)67, x3550 (7978), Microsoft Windows 2003 PCI QLogic QLE2360−E−SP11, 17, 23 FC−AL, EMC Y6, 7, 8, See13
x3650 (7979), x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y6, 8
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
57 Dell PowerEdge: 1900, 2900, 2950, 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP3, 11, 14, 15 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
58 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic QLE2460−E−SP3, 11, 14, 17 FC−AL, EMC Y6, 7, 8 See13
x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
59 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP11, 15, 20, FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, QLE2360−E−SP11, 15, 23 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Edition R212; PCI−X AX100
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x64] Standard: Edition,
SR2500/S5000PAL; Edition R212
Samsung ZSS132
60 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP3, 11, 35, 36 , FC−AL, EMC Y6, 8, 31 See13
[x64] Enterprise: Edition, Express, QLE2360−E−SP11, 15, 17, 23 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); Edition R212; PCI−X QLE2460−E−SP3, 11, 14, 15, 17 AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x64] Standard: Edition,
Lenovo SureServer: R630 G5, R650, R650 Edition R212
G5, T650
61 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP11, 15, 17, 23 , FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, QLE2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
IBM eServer 326m (Model 7969); 12
Edition R2 ; PCI−X AX100
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x64] Standard: Edition,
SR4850HW4/SR6850HW4; Edition R212
Lenovo SureServer: R630 G5, R650, R650
G5, T650
62 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP11, 15, 17, 23 , FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express, QLE2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Edition R212; PCI−X AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x64] Standard: Edition,
Lenovo SureServer: R630 G5, R650, R650 Edition R212
G5, T650
63 Dell PowerEdge 6850 Microsoft Windows 2003 PCI−X Dell 2362M11, 15, 29, 30 FC−AL, EMC Y6
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
64 Dell PowerEdge 1855 Microsoft Windows 2003 PCI−X Dell: 2342M11, 15, 20, LPe1105−M1, 3, 4, 21, FC−AL, EMC Y6
[x64] Enterprise: Edition, QME24623, 15, 33 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
65 Fujitsu Siemens Primergy: RX200 S2, RX300 Microsoft Windows 2003 PCI−X Emulex LP1050−E1, 5, 11, 57 FC−AL, EMC Y6, 8 See9
S2, TX200 S2, TX300 S2 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
66 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X Emulex LP1150−E1, 3, 4, 5, 11, 22 FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, FC−SW CLARiiON
HPQ Proliant DL360(G4)10; Edition R212; AX100
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung ZSS150; Edition R212
Sun: V20z, V40z, x4100, x4200
67 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X Emulex LP1150−E1, 3, 4, 5, 11, 22 FC−AL, EMC Y6, 8, 31 See9
[x64] Enterprise: Edition, FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Edition R212; AX100
NF520;
Microsoft Windows 2003
Samsung ZSS150; [x64] Standard: Edition,
Sun: x4100, x4200 Edition R212
68 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E1, 3, 5, 11, 22 FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212

11/02/2006 27 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
69 Dell PowerEdge: 1800, 2800, 2850, 6800, Microsoft Windows 2003 PCI−X Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8 See9
6850; [x64] Enterprise: Edition, 4, 5, 11 FC−SW CLARiiON
Edition R212; AX100
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
HPQ Proliant DL360(G4)10; [x64] Standard: Edition,
LangChao: NC3000, NC3500, NF500, Edition R212
NF520;
Samsung ZSS150;
Sun: V20z, V40z, x4100, x4200
70 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8, 31 See9
[x64] Enterprise: Edition, 4, 5, 11 FC−SW CLARiiON
IBM xSeries x3850/x366 (8863)25, 34; Edition R212; AX100
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung ZSS150 Edition R212
71 Fujitsu Siemens Primergy: RX600 S2, TX600 Microsoft Windows 2003 PCI−X Emulex: LPe111−E1, 3, 4, 11, 37 , FC−AL, EMC Y6, 7, 8, See9
S2 [x64] Enterprise: Edition, LPe1150−E1, 3, 5, 11, 59 FC−SW CLARiiON Y6, 8
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
72 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y6
(416654−B21), (416655−B21), [x64] Enterprise: Edition, HP c−Class Bladesystem (403621−B21)1, FC−SW CLARiiON
(416656−B21), (432636−B21); Edition R212; 37, 38 AX100
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x64] Standard: Edition,
Edition R212
73 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), [x64] Enterprise: Edition, HP c−Class Bladesystem (403619−B21)35, FC−SW CLARiiON
(416656−B21), (432636−B21); Edition R212; 51 AX100
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x64] Standard: Edition,
Edition R212
74 HPQ Proliant DL360(G4)10 Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)1, 2, 4, 5, 11 , A7388A FC−AL, EMC Y6
[x64] Enterprise: Edition, (LP1050)1, 2, 4, 5, 11 , AD167A/FC2143 FC−SW CLARiiON
Edition R212; (LP1150)1, 3, 4, 5, 61 , FCA2214 AX100
(QLA2340)11, 15, 17, 20 , FCA2408 (LP982)1,
Microsoft Windows 2003 2, 3, 4, 5, 11
[x64] Standard: Edition,
Edition R212
75 HPQ Proliant DL360(G4)10 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)3, 11, 14, FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, 15, AE369A/FC1243 (QLA2462)3, 11, 14, 15 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
76 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ: Dual−port Fibre Channel Adapter for FC−AL, EMC Y6
[x64] Enterprise: Edition, HP Proliant BL25p/BL45p 381881−B2111, FC−SW CLARiiON
Edition R212; 15, 16, 17 , Emulex−based BL25/30/35/45p AX100
Fibre Channel Mezzanine HBA −
Microsoft Windows 2003 394588−B211, 11, 40, 41
[x64] Standard: Edition,
Edition R212
77 IBM xSeries x3850/x366 (8863)25, 34 Microsoft Windows 2003 PCI−X IBM 19K1246 (QLA2310)11, 15, 17, 20, 32 FC−AL, EMC Y6, 31
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
78 NEC Express 5800: 110Rg−1, 180Re−3 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)1, 2, 4, 5, 11, 19 FC−AL, EMC Y6
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
79 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)1, 2, 4, 5, 11, 19 FC−AL, EMC Y6, 8 See9
120Ri−2 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
80 NEC Express 5800: 120Rf−1, 120Rh−2 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)1, 2, 4, 5, 11, 19 FC−AL, EMC Y6, 8
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
81 IBM xSeries x3850/x366 (8863)25, 34 Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP11, 15, 17, 20 FC−AL, EMC Y6, 8, 31 See13
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212

11/02/2006 28 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
82 Dell PowerEdge: 1800, 2800, 2850, 6800, Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP11, 15, 20 FC−AL, EMC Y6, 8 See13
6850 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
83 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP3, 11, 14, 17 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
84 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic: QLA2340−E−SP11, 15, 17, 20 , FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, QLA2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
HPQ Proliant DL360(G4)10; Edition R212; AX100
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung ZSS150; Edition R212
Sun: V20z, V40z, x4100, x4200
85 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X18 HPQ Dual−port Fibre Channel Adapter for FC−AL, EMC Y6
[x64] Enterprise: Edition, HP Proliant BL25p/BL45p 381881−B2111, FC−SW CLARiiON
Edition R212; 15, 16, 17 AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
86 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X18 HPQ Emulex−based BL25/30/35/45p Fibre FC−AL, EMC N
[x64] Enterprise: Edition, Channel Mezzanine HBA − 394588−B211, FC−SW CLARiiON
Edition R212; 11, 40, 41 AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
87 HPQ Proliant BL20p: (G3), (G4) Microsoft Windows 2003 PCI−X18 HPQ: Dual−port Fibre Channel Adapter for FC−AL, EMC N
[x64] Enterprise: Edition, HP Proliant BL20p (G3) 361426−B2111, 15, FC−SW CLARiiON
Edition R212; 17, 42, Emulex−based BL20p (G3) Fibre AX100
Channel Mezzanine HBA − 394757−B211,
Microsoft Windows 2003 4, 5, 11, 40
[x64] Standard: Edition,
Edition R212
88 IBM xSeries x3800/x260 (8865)25 Microsoft Windows 2003 PCI−X24 Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8, 31 See9
[x64] Enterprise: Edition, 4, 5, 11 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
89 IBM xSeries: x3800/x260 (8865)25, Microsoft Windows 2003 PCI−X24 Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8 See9
x3950/x3950E/x460 (8872, 8874)25 [x64] Enterprise: Edition, 4, 5, 11 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
90 IBM xSeries x3800/x260 (8865)25 Microsoft Windows 2003 PCI−X24 IBM 19K1246 (QLA2310)11, 15, 17, 20, 32 FC−AL, EMC Y6, 31
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
91 IBM xSeries: x3800/x260 (8865)25, Microsoft Windows 2003 PCI−X24 IBM: 19K1246 (QLA2310)11, 15, 17, 20, 32 , FC−AL, EMC Y6
x3950/x3950E/x460 (8872, 8874)25 [x64] Enterprise: Edition, 24P0960 (QLA2340)11, 15, 17, 20, 43 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
92 IBM xSeries x3800/x260 (8865)25 Microsoft Windows 2003 PCI−X24 QLogic QLA2340−E−SP11, 15, 17, 20 FC−AL, EMC Y6, 8, 31 See13
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
93 IBM xSeries: x3800/x260 (8865)25, Microsoft Windows 2003 PCI−X24 QLogic QLA2340−E−SP11, 15, 17, 20 FC−AL, EMC Y6, 8 See13
x3950/x3950E/x460 (8872, 8874)25 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
94 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X39 Emulex: LP1050−E1, 2, 4, 5, 11 , LP1150−E1, FC−AL, EMC Y6, 8, See9
[x64] Enterprise: Edition, 3, 4, 5, 11, 22 , LP982−E1, 2, 4, 5, 11 FC−SW CLARiiON Y6, 8, 31
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
95 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X39 QLogic: QLA2340−E−SP11, 15, 17, 20 , FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, QLA2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212

11/02/2006 29 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
96 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M11, 15, 20, LPe1105−M1, 3, 4, 21, FC−AL, EMC Y6
[x64] Enterprise: Edition, Express, QME24623, 15, 33 FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
97 HPQ Proliant DL380(G4)10 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E1, 2, 3, 4, 5, 11 FC−AL, EMC Y6, 7, 8 See9
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
98 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E1, 3, 4, 11, 37 FC−AL, EMC Y6, 7, 8 See9
HPQ Proliant DL380(G4)10 [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
99 HPQ Proliant: DL380(G4)10, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E1, 3, 4, 5, 11, 21 FC−AL, EMC Y6, 7, 8 See9
DL580(G4) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
100 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E1, 3, 5, 11, 59 FC−AL, EMC Y6, 7, 8 See9
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
101 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex: LP1150−E1, 3, 4, 5, 11, 22 , FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express, LPe1150−E1, 3, 4, 5, 11, 21 FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
102 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E1, 3, 4, 11, 37 , FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, Express, LPe1150−E1, 3, 5, 11, 59 FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
103 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 3, 4, FC−AL, EMC Y6
[x64] Enterprise: Edition, Express, 5, 21, AD167A/FC2143 (LP1150)1, 3, 4, 5, 61 , FC−SW CLARiiON
Edition R212; PCI−X AE311A/FC1142SR (QLE2460)3, 11, 14, 15, AX100
17
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
104 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 3, 4, FC−AL, EMC Y6, 7
[x64] Enterprise: Edition, Express, 5, 21, AE311A/FC1142SR (QLE2460)3, 11, FC−SW CLARiiON
Edition R212; PCI−X 14, 15, 17 AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
105 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)3, 11, 14, FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, Express, 15, AE369A/FC1243 (QLA2462)3, 11, 14, 15 ; FC−SW CLARiiON
Edition R212; PCI−X AX100
QLogic QLA2460−E−SP3, 11, 14, 15, 17
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
106 HPQ Proliant DL580(G3)10 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP3, 11, 35, 36 FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
107 HPQ Proliant: DL380(G4)10, DL580(G3)10 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP11, 15, 17, 23 FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
108 HPQ Proliant: DL380(G4)10, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP3, 11, 14, 15, 17 FC−AL, EMC Y6, 7, 8 See13
DL580(G3)10, DL580(G4) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R212; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
109 Fujitsu Siemens Primergy RX800 S2 Microsoft Windows 2003 PCI, Emulex LP1050−E1, 5, 11, 57 FC−AL, EMC Y6, 8 See9
[x64] Enterprise: Edition, PCI−X FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212

11/02/2006 30 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
110 HPQ Proliant: DL380(G4)10, DL38510, Microsoft Windows 2003 PCI, Emulex LP1150−E1, 3, 4, 5, 11, 22 FC−AL, EMC Y6, 8 See9
DL580(G3)10, DL58510 [x64] Enterprise: Edition, PCI−X FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
111 Dell PowerEdge 1850; Microsoft Windows 2003 PCI, Emulex: LP1050−E1, 2, 4, 5, 11 , LP982−E1, 2, FC−AL, EMC Y6, 8 See9
HPQ Proliant: DL380(G4)10, DL38510, [x64] Enterprise: Edition, PCI−X 4, 5, 11 FC−SW CLARiiON
DL580(G3)10, DL58510 Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
112 HPQ Proliant: DL380(G4)10, DL38510, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)1, 2, 4, 5, 11 , A7388A FC−AL, EMC Y6
DL58510 [x64] Enterprise: Edition, PCI−X (LP1050)1, 2, 4, 5, 11 , AD167A/FC2143 FC−SW CLARiiON
Edition R212; (LP1150)1, 3, 4, 5, 61 , FCA2214 AX100
(QLA2340)11, 15, 17, 20 , FCA2408 (LP982)1,
Microsoft Windows 2003 2, 3, 4, 5, 11
[x64] Standard: Edition,
Edition R212
113 HPQ Proliant: DL380(G4)10, DL38510, Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)3, 11, 14, FC−AL, EMC Y6, 8 See13
DL58510 [x64] Enterprise: Edition, PCI−X 15, AE369A/FC1243 (QLA2462)3, 11, 14, 15 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
114 Dell PowerEdge 1850 Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP11, 15, 20 FC−AL, EMC Y6, 8 See13
[x64] Enterprise: Edition, PCI−X FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
115 HPQ Proliant: DL380(G4)10, DL38510, Microsoft Windows 2003 PCI, QLogic: QLA2340−E−SP11, 15, 17, 20 , FC−AL, EMC Y6, 8 See13
DL580(G3)10, DL58510 [x64] Enterprise: Edition, PCI−X QLA2460−E−SP3, 11, 14, 15, 17 FC−SW CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
116 Dell PowerEdge 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP3, 11, 14, 15 FC−AL, EMC Y6, 7, 8 See13
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
12
Edition R2 ; PCI−X AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212;
Microsoft Windows 2003
[x64] Storage Server:
Enterprise Edition R2,
Standard Edition R2
117 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX: (LP1050)1, 2, 4, FC−AL, EMC Y
[x64] Standard Edition 44, 62,
(LP1050)1, 2, 4, 44, 62, 63 FC−SW CLARiiON
R212 AX100
118 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)1, 2, 50, FC−AL, EMC Y6
[x64] Standard Edition PCI−X 64 FC−SW CLARiiON
R212 AX100
119 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y6
(403434−B21), (407234−B21), [x64] Standard: Edition, Express HP c−Class Bladesystem (403621−B21)1, FC−SW CLARiiON
(407235−B21); Edition R212 37, 38 AX100
HPQ Proliant BL480c (404704−B21)
120 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403434−B21), (407234−B21), [x64] Standard: Edition, Express HP c−Class Bladesystem (403619−B21)35, FC−SW CLARiiON
(407235−B21); Edition R212 51 AX100
HPQ Proliant BL480c (404704−B21)
121 Dell PowerEdge: 2900, 2950 Microsoft Windows 2003 PCI Emulex: LP1050−E1, 2, 4, 5, 11 , FC−AL, EMC Y6, 8 See9
[x64] Storage Server: Express, LP1050Ex−E1, 2, 3, 4, 11 , LP982−E1, 2, 4, 5, FC−SW CLARiiON
Enterprise Edition R2, PCI−X 11, LPe111−E1, 3, 4, 11, 37 , LPe1150−E1, 3, AX100
Standard Edition R2 4, 11, 21

122 Dell PowerEdge: 2900, 2950, 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP3, 11, 14, 15 FC−AL, EMC Y6, 8 See13
[x64] Storage Server: Express, FC−SW CLARiiON
Enterprise Edition R2, PCI−X AX100
Standard Edition R2
123 Dell PowerEdge: 2900, 2950 Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP11, 15, 20, FC−AL, EMC Y6, 8 See13
[x64] Storage Server: Express, QLE220−E−SP3, 11, 35, 36 , FC−SW CLARiiON
Enterprise Edition R2, PCI−X QLE2360−E−SP11, 15, 23 AX100
Standard Edition R2
124 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X24 Emulex: LP101−E1, 2, 11, 54, 56 , LP1050−E1, FC−AL, EMC Y6, 8 See9
8874)25 [x64]: DataCenter, 2, 11, 41, 54, 55 , LP1050−E1, 2, 4, 5, 11 , FC−SW CLARiiON
DataCenter R212 LP982−E1, 2, 11, 41, 54, 55 , LP982−E1, 2, 4, 5, AX100
11

125 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X24 IBM 19K1246: (QLA2310)11, 15, 17, 20, 32 , FC−AL, EMC Y6
8874)25 [x64]: DataCenter, (QLA2310)11, 20, 32, 46, 47, 48 ; FC−SW CLARiiON
DataCenter R212 AX100
IBM 24P0960: (QLA2340)11, 15, 17, 20, 43 ,
(QLA2340)11, 20, 43, 46, 47, 48

11/02/2006 31 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
126 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X24 QLogic: QLA2340−E−SP11, 15, 17, 20 , FC−AL, EMC Y6, 8 See13
8874)25 [x64]: DataCenter, QLA2340−E−SP11, 20, 47, 48 FC−SW CLARiiON
DataCenter R212 AX100
127 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)1, 2, 44, FC−AL, EMC Y
[x64]: DataCenter, 45 FC−SW CLARiiON
Enterprise Edition, AX100
Standard Edition
128 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)1, 2, 49, FC−AL, EMC N
[x64]: DataCenter, PCI−X 50 FC−SW CLARiiON
Enterprise Edition, AX100
Standard Edition,
Standard Edition R212
129 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel Module FC−SW EMC Y6, 7, 8, See9
[x64] Enterprise: Edition, Express AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
130 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel Module FC−SW EMC Y6, 7, 8, See13
[x64] Enterprise: Edition, Express AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8,
Edition R212; AX100 Y6, 8, 31
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
131 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y6, 7, 8, See13
[x64] Enterprise: Edition, Express AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8,
Edition R212; AX100 Y6, 8, 31
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
132 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y6, 7, 8, See9
[x64] Enterprise: Edition, Express AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8,
Edition R212; AX100 Y6, 8, 31
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
133 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel Module FC−SW EMC Y6, 7, 8, See13
[x64] Enterprise: Edition, Express, AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8,
Intel: SR4850HW4−M/SR6850HW4−M, Edition R212; PCI−X AX100 Y6, 8, 31
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x64] Standard: Edition,
G5, T650 Edition R212
134 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel Module FC−SW EMC Y6, 7, 8, See9
[x64] Enterprise: Edition, Express, AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8,
Intel: SR4850HW4−M/SR6850HW4−M, Edition R212; PCI−X AX100 Y6, 8, 31
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x64] Standard: Edition,
G5, T650 Edition R212
135 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual port: FC−SW EMC Y6
[x64] Enterprise: Edition, for NovaScale Blade Series CLARiiON
Edition R212; CFSN202−110011, 15, 17, 26 , mini for AX100
NovaScale Blade 2021 CFSN202−210011,
Microsoft Windows 2003 15, 17, 26 ;
[x64] Standard: Edition,
Edition R212 Bull: SBEFCM (SFF) Mezzanine HBA3, 11,
15, 17, 26 , SBEFCM4 (SFF) 4Gb Mezzanine
HBA3, 11, 15, 65, 66
136 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel Module FC−SW EMC Y6, 8 See13
[x64] Enterprise: Edition, AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
137 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel Module FC−SW EMC Y6, 8, See9
[x64] Enterprise: Edition, AHWFCMOD3, 11, 15, 17, 29, 30 CLARiiON Y6, 8, 31
Edition R212; AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
138 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA3, 11, FC−SW EMC Y6
[x64] Enterprise: Edition, 15, 17, 26 , SBEFCM4 (SFF) 4Gb Mezzanine CLARiiON
Edition R212; HBA3, 11, 15, 65, 66 AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R212
1. BIOS 1.70a3
2. Firmware Version 1.91a5
3. SNIA HBA API Supported.
4. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
5. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
6. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
7. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
8. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
9. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
10. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
11. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.

11/02/2006 32 CLARiiON AX100


CLARiiON AX100

12. VDS (Virtual Disk Service) is currently supported for Windows 2003 R2 operating systems. EMC Solutions Enabler 6.2 (minimum version) is required to support VDS for Windows 2003
R2.
13. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
14. BIOS 1.08
15. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
16. BIOS 1.48
17. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
18. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
19. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
20. BIOS 1.47
21. Firmware Version 2.50a6
22. Firmware Version 2.10a10
23. BIOS 1.05
24. Accepts PCI−X 1.0 and 2.0 HBAs.
25. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
26. BIOS 1.43
27. Driver Version 9.0.2.17 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
28. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
29. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
30. BIOS 1.06
31. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar SCSI.)
32. This HBA is equivalent to the QLogic QLA2310.
33. BIOS 1.11
34. x64 versions of Windows 2003 require the Adaptec SAS SCSI driver from the IBM Support website.
35. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
36. BIOS 1.02
37. Firmware Version 2.50a8
38. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
39. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
40. Firmware Version 1.91a2
41. Driver Version 1.11a3
42. BIOS 1.45
43. This HBA is equivalent to the QLogic QLA2340.
44. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
45. Driver Version 1.10x1
46. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
47. Driver Version 9.1.2.16 STORPort Miniport Driver
48. Driver Version 9.1.2.15 STORPort Miniport Driver
49. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
50. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
51. BIOS 1.16
52. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
53. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
54. Driver Version 1.20a3 STORPort Miniport Driver
55. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
56. Driver Version 1.11a3 STORPort Miniport Driver
57. Firmware Version 1.91a1
58. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
59. Firmware Version 2.50a4
60. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com Requires Microsoft STORPort hotfix
Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently requires Service Pack 1 (SP1) to be installed before the hotfix
can be installed. STORPort Miniport Driver
61. Firmware Version 2.10a9
62. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
63. RPQ or Unisys Custom Engineering Request (CER) required.
64. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
65. BIOS 1.12
66. Driver Version 9.1.2.11
67. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.

Microsoft Windows 2003 [x86]


Where replication of boot LUN is supported, any use of the replicated boot LUN other than in original host may lead to hardware/configuration mismatch that
render the replicated boot LUN unusable. Any issues that arise in trying to use the boot LUN in a host that is non−identical to the source host is outside of the
scope of what EMC can support. Also, in any case due to environment failure where I/O is not written back to the source LUN, or if the source LUN is not left
in a stable state by the source host, the replicated LUN is not guaranteed to be any more usable than the source. Also, there may be specific software
licensing that needs to be investigated when duplicating the boot LUN.

11/02/2006 33 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
1 Unisys ES7000/550 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86] DataCenter 119 FC−SW CLARiiON
AX100
2 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
8874)61 [x86] DataCenter LP1050−E2, 6, 8, 9, 22, 24 , LP982−E2, 6, 8, FC−SW CLARiiON
9, 24, 26 AX100
3 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 IBM: 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3
8874)61 [x86] DataCenter 108,24P0960 (QLA2340)2, 14, 25, 29, 37, FC−SW CLARiiON
62 AX100
4 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 QLogic QLA2340−E−SP2, 14, 25, 37 FC−AL, EMC Y3, 4 See11
8874)61 [x86] DataCenter FC−SW CLARiiON
AX100
5 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y3
[x86] DataCenter SP116 PCI−X 123, 125 FC−SW CLARiiON
AX100
6 Unisys ES7000/550 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86] DataCenter: R21, SP1 132 FC−SW CLARiiON
AX100
7 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
8874)61 [x86] DataCenter: R21, SP1 LP1050−E2, 5, 6, 8, 9, 17 , LP1050−E2, 6, 7, FC−SW CLARiiON
9, 32, LP982−E2, 5, 6, 8, 9, 17 , LP982−E2, AX100
6, 7, 9, 32

8 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 IBM 19K1246: (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
8874)61 [x86] DataCenter: R21, SP1 108, (QLA2310)2, 14, 28, 67, 108 ; FC−SW CLARiiON
AX100
IBM 24P0960: (QLA2340)2, 13, 14, 15, 29,
62, (QLA2340)2, 14, 28, 62, 67

9 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X63 QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4 See11
8874)61 [x86] DataCenter: R21, SP1 QLA2340−E−SP2, 14, 28, 67 FC−SW CLARiiON
AX100
10 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/540 [x86] DataCenter: R21, 114 FC−SW CLARiiON
SP116 AX100
11 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 96, FC−AL, EMC Y3
[x86] DataCenter: R21, 113 FC−SW CLARiiON
SP116 AX100
12 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX: (LP1050)9, FC−AL, EMC Y3
[x86] DataCenter: R21, 111, 115, (LP1050)9, 113 FC−SW CLARiiON
SP116 AX100
13 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y
[x86] DataCenter: R21, 109, 110, 111 FC−SW CLARiiON
SP116; AX100
Microsoft Windows 2003
[x86] Enterprise Edition
SP116
14 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y3
[x86] DataCenter: R21, PCI−X 123, 126 FC−SW CLARiiON
SP116; AX100
Microsoft Windows 2003
[x86]: Enterprise Edition
R21, Standard Edition R21
15 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC Y
[x86] DataCenter: R21, 109, 110 FC−SW CLARiiON
SP116; AX100
Microsoft Windows 2003
[x86]: Enterprise Edition
SP116, Standard Edition
SP116
16 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 121 FC−AL, EMC Y3
[x86] DataCenter21 FC−SW CLARiiON
AX100
17 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/540 [x86] DataCenter21 128 FC−SW CLARiiON
AX100
18 NEC Express 5800 320Ma83, 94 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 25, 37, FC−AL, EMC Y3 See11
[x86] Enterprise Edition 68 FC−SW CLARiiON
AX100
19 Stratus ftServer: 430083, 460083 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 37, 68, FC−AL, EMC N See11
[x86] Enterprise Edition 98 FC−SW CLARiiON
AX100
20 Stratus ftServer: 230065, 330045, 430083, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 43, 44 , FC−AL, EMC N See11
460083, 560045, 660045 [x86] Enterprise Edition QLA210−E−SP19, 41, 43, 54 FC−SW CLARiiON
AX100
21 HPQ Proliant: BL460c (404664−B21), BL465c Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403433−B21), BL465c (403434−B21), [x86] Enterprise Edition Express HP c−Class Bladesystem FC−SW CLARiiON
BL465c (407234−B21), BL465c (403619−B21)53, 88, 89 AX100
(407235−B21), BL480c (404704−B21)
22 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 25, 37, FC−AL, EMC Y3 See11
[x86] Enterprise Edition 68 FC−SW CLARiiON
AX100
23 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 25, 37, FC−AL, EMC N See11
[x86] Enterprise Edition 68, 98 FC−SW CLARiiON
AX100

11/02/2006 34 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
24 NEC Express 5800 320Ma83, 94 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 28, 67, FC−AL, EMC Y3 See11
[x86] Enterprise Edition SP1 68 FC−SW CLARiiON
AX100
25 Stratus ftServer 5700 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 28, 67, FC−AL, EMC N See11
[x86] Enterprise Edition SP1 68, 98 FC−SW CLARiiON
AX100
26 Stratus ftServer: 430083, 460083 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 67, 68, FC−AL, EMC N See11
[x86] Enterprise Edition SP1 98 FC−SW CLARiiON
AX100
27 Stratus ftServer: 230065, 330045, 430083, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 44, 79 , FC−AL, EMC N See11
460083, 560045, 660045 [x86] Enterprise Edition SP1 QLA210−E−SP19, 41, 54, 79 FC−SW CLARiiON
AX100
28 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC Y3 See11
[x86] Enterprise Edition SP1 68 FC−SW CLARiiON
AX100
29 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC N See11
[x86] Enterprise Edition SP1 68, 98 FC−SW CLARiiON
AX100
30 Unisys: ES3220, ES3220L Microsoft Windows 2003 PCI, Unisys FCH752313−PCX: (LP1050)6, 9, FC−AL, EMC N
[x86] Enterprise Edition PCI−X 111, (LP1050)9, 111, 115 FC−SW CLARiiON
SP116 AX100
31 HPQ Proliant: BL460c (404664−B21), BL465c Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403433−B21), BL465c (403434−B21), [x86] Enterprise Edition: Express HP c−Class Bladesystem FC−SW CLARiiON
BL465c (407234−B21), BL465c R21, SP1 (403619−B21)50, 88, 89 AX100
(407235−B21), BL480c (404704−B21)
32 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), [x86] Enterprise Edition: HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); R21, SP1; (403619−B21)50, 88, 89 AX100
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x86] Standard: Edition,
Edition R21, Edition SP1
33 NEC Express 5800: 320Mc−R, 340Hb−R Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 28, FC−AL, EMC Y3
[x86] Enterprise Edition: 29, 67, 68 FC−SW CLARiiON
R21, SP116 AX100
34 NEC Express 5800: 320La−R104, 320La104, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 28, FC−AL, EMC Y3
320Lb−R104, 105, 320Lb2−R, 320Lb104, 105, [x86] Enterprise Edition: 29, 67, 68, 103 FC−SW CLARiiON
320Lc, 320Lc−R, 330Ma−R104, 330Mb−R104, R21, SP116 AX100
106, 107, 340Ha−R104, 106, 107

35 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP2, 14, 28, 29, 67, FC−AL, EMC Y3, 4 See11
320Lc−R [x86] Enterprise Edition: 68 FC−SW CLARiiON
R21, SP116 AX100
36 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, FC−AL, EMC Y3
[x86] Enterprise Edition: 111, 117 FC−SW CLARiiON
R21, SP116 AX100
37 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 116 FC−AL, EMC Y3
Model 300 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116 AX100
38 Unisys: FS1300, Libra Model 300 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86] Enterprise Edition: 111, 117 FC−SW CLARiiON
R21, SP116 AX100
39 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/530, ES7000/540, ES7000/550, [x86] Enterprise Edition: 118 FC−SW CLARiiON
ES7000/560 [32−Bit] R21, SP116 AX100
40 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 96, FC−AL, EMC Y3
[x86] Enterprise Edition: 116 FC−SW CLARiiON
R21, SP116 AX100
41 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI Emulex LP101−E2, 6, 9, 17, 30 FC−AL, EMC Y3, 4 See10
DL36018, DL58018, ML350(G2)18, ML35018, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, R21, SP116; AX100
ML530(G3)18, ML53018, ML57018, ML75018;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x340 (4500R), x342, x350 SP116
(6000R), x370
42 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI Emulex LP982−E2, 5, 6, 8, 9, 17 FC−AL, EMC Y3, 4 See10
DL36018, DL58018, ML350(G2)18, ML35018, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, R21, SP116; AX100
ML530(G3)18, ML53018, ML57018, ML75018;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x342, x350 (6000R), x370 SP116
43 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 7, 9, 32 , LP982−E2, FC−AL, EMC Y3, 4 See10
2500, 255080, 4300, 4350, 4400, 6100, 6300, [x86] Enterprise Edition: 5, 6, 7, 8, 9 FC−SW CLARiiON
6350, 6400, 6450, 8450 R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
44 Dell PowerEdge: 1550, 2450, 2500, 255080, Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 7, 8, 9 , FC−AL, EMC Y3, 4 See10
4400, 6350, 6400, 645081, 8450 [x86] Enterprise Edition: LP1150−E2, 7, 8, 9, 19, 23, 32 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
45 HPQ Proliant: 850018, DL32018, Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 8, 9, 17 , FC−AL, EMC Y3, 4 See10
DL360(G2)18, DL36018, DL380(G2)18, [x86] Enterprise Edition: LP1150−E2, 8, 9, 17, 19, 23, 30 FC−SW CLARiiON
DL380(G3)18, DL38018, DL58018, R21, SP116; AX100
ML350(G2)18, ML35018, ML370(G2)18,
ML37018, ML530(G2)18, ML530(G3)18, Microsoft Windows 2003
ML53018, ML57018, ML75018; [x86] Standard Edition: R21,
SP116
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370

11/02/2006 35 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
46 Fujitsu Siemens Primergy: BX60097, BX620 Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q2, 14, 19, FC−AL, EMC Y3
S2F57, BX620 S257, BX620 S3, BX62057, [x86] Enterprise Edition: 58, 59 FC−SW CLARiiON
BX630 (2−way), BX630 (4−way), BX630 R21, SP116; AX100
(8−way), BX66057
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
47 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI HPQ: A7298A (LP982)2, 6, 8, 9, 17, 30 , FC−AL, EMC Y3
DL36018, DL380(G2)18, DL380(G3)18, [x86] Enterprise Edition: A7388A (LP1050)2, 6, 8, 9, 17, 30 , FC−SW CLARiiON
DL38018, DL58018, ML350(G2)18, ML35018, R21, SP116; AD167A/FC2143 (LP1150)8, 9, 17, 19, 30, AX100
ML370(G2)18, ML37018, ML530(G2)18, 129, FCA2214 (QLA2340)2, 13, 14, 15, 29 ,
ML53018, ML57018, ML75018 Microsoft Windows 2003 FCA2408 (LP982)2, 6, 8, 9, 17, 19, 30
[x86] Standard Edition: R21,
SP116
48 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
x330, x335, x340 (4500R), x342, x350 [x86] Enterprise Edition: 108 FC−SW CLARiiON
(6000R), x370 R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
49 IBM xSeries: x230, x240, x250, x330, x335, Microsoft Windows 2003 PCI IBM 24P0960 (QLA2340)2, 13, 14, 15, 29, FC−AL, EMC Y3
x340 (4500R), x342, x350 (6000R), x370 [x86] Enterprise Edition: 62 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
50 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)2, 19, 20, 29, 92 , FC−AL, EMC Y3, 4 See11
x330, x335, x340 (4500R), x342, x350 [x86] Enterprise Edition: 39M5895 (QLA2462)2, 19, 20, 29, 92 FC−SW CLARiiON
(6000R), x370 R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
51 NEC Express 5800: 120Rd−1, 120Rf−2, Microsoft Windows 2003 PCI NEC N8190−120 (LP1050)2, 6, 7, 8, 9, 32, FC−AL, EMC Y3
140Hd, 140Rc−4, 180Rd−4 [x86] Enterprise Edition: 33 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
52 NEC Express 5800: 320La−R104, 320La104, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 28, FC−AL, EMC Y3
320Lb−R104, 105, 320Lb104, 105 [x86] Enterprise Edition: 29, 67 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
53 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 44, 55, FC−AL, EMC Y3, 4 See11
DL36018, DL58018, ML350(G2)18, ML35018, [x86] Enterprise Edition: 75, QLA210−E−SP19, 41, 54, 55 , FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, R21, SP116; QLA2340−E−SP2, 13, 14, 15 , AX100
ML530(G3)18, ML53018, ML57018, ML75018; QLA2460−E−SP2, 13, 15, 19, 20, 29
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x340 (4500R), x342, x350 SP116
(6000R), x370
54 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 75, 77 , FC−AL, EMC Y3, 4 See11
2500, 255080, 4300, 4350, 4400, 6100, 6300, [x86] Enterprise Edition: QLA210−E−SP19, 41, 55, 64 , FC−SW CLARiiON
6350, 6400, 6450, 8450 R21, SP116; QLA2340−E−SP2, 14, 27, 28 , AX100
QLA2460−E−SP2, 15, 19, 20, 102
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
55 Unisys: ES3120, ES3120L, ES3140, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES3140L [x86] Enterprise Edition: 112 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
56 Fujitsu Siemens Primergy: RX200 S2, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 5, 9, 19, 76 FC−AL, EMC Y3, 4, See10
S2, TX600 S2 [x86] Enterprise Edition: Express FC−SW CLARiiON Y3, 4, 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
57 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex LPe111−E2, 7, 9, 19, 46, 60 FC−AL, EMC Y3, 4 See10
2850, 6800, 6850; [x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP116; AX100
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
Fujitsu Siemens Primergy RX300 S3; [x86] Standard Edition: R21,
HPQ Proliant: DL360(G4)18, DL380(G4)18, SP116
DL580(G3)18;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
58 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex LPe111−E2, 7, 9, 19, 46, 60 FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; R21, SP116; AX100
Fujitsu Siemens Primergy RX300 S3; Microsoft Windows 2003
HPQ Proliant: DL360(G4)18, DL380(G4)18, [x86] Standard Edition: R21,
DL580(G3)18; SP116
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D

11/02/2006 36 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
59 Fujitsu Siemens Primergy RX300 S3 Microsoft Windows 2003 PCI Emulex LPe1150−E2, 9, 19, 30, 95 FC−AL, EMC Y3, 4, See10
[x86] Enterprise Edition: Express FC−SW CLARiiON Y3, 4, 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
60 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express LP1050−E2, 5, 6, 8, 9, 17 , LP1150−E2, 8, 9, FC−SW CLARiiON
R21, SP116; 17, 19, 23, 30 , LP982−E2, 5, 6, 8, 9, 17 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
61 Dell PowerEdge 1950 Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 7, 8, 9 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express LP982−E2, 5, 6, 7, 8, 9 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
62 IBM xSeries x3455 (7984) Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 5, 6, 7, 8, 9, 19 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express LPe1150−E2, 7, 8, 9, 19, 30, 35 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
63 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 5, 6, 8, 9, 17, 19 , FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express LPe1150−E2, 8, 9, 17, 19, 30, 35 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; R21, SP116; AX100
HPQ Proliant: DL360(G4)18, DL380(G4)18, Microsoft Windows 2003
DL580(G3)18; [x86] Standard Edition: R21,
SP116
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
64 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 5, 6, 8, 9, 17, 19 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express LPe1150−E2, 8, 9, 17, 19, 30, 35 FC−SW CLARiiON
HPQ Proliant: DL360(G4)18, DL380(G4)18, R21, SP116; AX100
DL580(G3)18;
Microsoft Windows 2003
LangChao: NC3000, NC3500, NF500, [x86] Standard Edition: R21,
NF520; SP116
Samsung: ZSS230, ZSS230D
65 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 7, 8, 9, 19 , FC−AL, EMC Y3, 4 See10
2850, 6800, 6850 [x86] Enterprise Edition: Express LPe1150−E2, 7, 8, 9, 19, 35 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
66 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)2, 8, 9, 17, 19, 30 FC−AL, EMC Y3, Y3,
[x86] Enterprise Edition: Express FC−SW CLARiiON 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
67 HPQ Proliant: DL360(G4)18, DL380(G4)18, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, Y3,
DL580(G3)18 [x86] Enterprise Edition: Express 17, 19, 30, 35 FC−SW CLARiiON 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
68 HPQ Proliant: DL360(G4)18, DL380(G4)18 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)2, FC−AL, EMC Y3, Y3,
[x86] Enterprise Edition: Express 13, 15, 19, 20, 69 FC−SW CLARiiON 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
69 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)7, 9, 32, 33, 35 FC−AL, EMC Y3, 4 See10
120Ri−2, 140Hf, 140Re−4 [x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
70 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)7, 9, 32, 33, 35 FC−AL, EMC Y3, 4, 84 See10, 11
[x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
71 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 44, 55, 75 FC−AL, EMC Y3, 4, 31 See11
[x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116

11/02/2006 37 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
72 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP2, 19, 48, 49, 50 FC−AL, EMC Y3, 4 See11
2850, 6800, 6850; [x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP116; AX100
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
IBM xSeries x3455 (7984); [x86] Standard Edition: R21,
LangChao: NC3000, NC3500, NF500, SP116
NF520;
Samsung: ZSS230, ZSS230D
73 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 44, 55, FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express 75, QLA200−E−SP2, 41, 75, 77 , FC−SW CLARiiON
R21, SP116; QLA210−E−SP19, 41, 55, 64 , AX100
QLA2340−E−SP2, 14, 27, 28
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
74 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4, See11
[x86] Enterprise Edition: Express QLA2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON Y3, 4, 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
75 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 50 , FC−AL, EMC Y3, 4, 12 See11
[x86] Enterprise Edition: Express QLE2360−E−SP2, 29, 38, 39, 40 , FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; R21, SP116; QLE2460−E−SP2, 13, 15, 19, 20, 29 AX100
LangChao: NC3000, NC3500, NF500, Microsoft Windows 2003
NF520; [x86] Standard Edition: R21,
SP116
Samsung: ZSS150, ZSS230, ZSS230D
76 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 50 , FC−AL, EMC Y3, 4, 31 See11
[x86] Enterprise Edition: Express QLE2360−E−SP2, 29, 38, 39, 40 , FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP116; QLE2460−E−SP2, 13, 15, 19, 20, 29 AX100
NF520;
Microsoft Windows 2003
Samsung: ZSS230, ZSS230D [x86] Standard Edition: R21,
SP116
77 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 27, 28, 40 , FC−AL, EMC Y3, 4 See11
2850, 6800, 6850 [x86] Enterprise Edition: Express QLE2460−E−SP2, 19, 20, 27, 28 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
78 IBM xSeries x3455 (7984) Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 28, 29, 40, 131 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express QLE2360−E−SP2, 28, 40, 102, 131 , FC−SW CLARiiON
R21, SP116; QLE2460−E−SP2, 15, 19, 20, 28, 102 , AX100
QLE2460−E−SP2, 15, 19, 20, 28, 29
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
79 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 29, 38, 39, 40 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express QLE2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP116; AX100
NF520;
Microsoft Windows 2003
Samsung: ZSS230, ZSS230D [x86] Standard Edition: R21,
SP116
80 IBM eServer 326m (Model 7969) Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 5, 6, 8, 9, 19 FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
81 IBM: eServer 326m (Model 7969), xSeries Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 5, 6, 8, 9, 19 FC−AL, EMC Y3, 4 See10
x3550 (7978), xSeries x3650 (7979), xSeries [x86] Enterprise Edition: Express, FC−SW CLARiiON
x3755 (8877) R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
82 Fujitsu Siemens Primergy: RX220, RX600 S3, Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 5, 9, 19, 76 FC−AL, EMC Y3, 4, See10
TX600 S3 [x86] Enterprise Edition: Express, FC−SW CLARiiON Y3, 4, 12
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
83 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LP1150−E2, 8, 9, 17, 19, 23, 30 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), R21, SP116; PCI−X AX100
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP116
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 38 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
84 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E2, 7, 9, 19, 46, 60 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; R21, SP116; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x86] Standard Edition: R21,
SP116
Fujitsu Siemens Primergy: RX200 S3, RX220,
RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
85 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LPe111−E2, 7, 9, 19, 46, 60 FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S3, RX220, R21, SP116; PCI−X AX100
RX600 S3, TX300 S3, TX600 S3;
Microsoft Windows 2003
IBM eServer 326m (Model 7969); [x86] Standard Edition: R21,
Intel: SC5300AF2, SE7520BB2, SP116
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
86 Fujitsu Siemens Primergy: RX200 S3, RX220, Microsoft Windows 2003 PCI Emulex LPe1150−E2, 9, 19, 30, 95 FC−AL, EMC Y3, 4, See10
RX600 S3, TX300 S3, TX600 S3 [x86] Enterprise Edition: Express, FC−SW CLARiiON Y3, 4, 12
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
87 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, LP1050−E2, 5, 6, 8, 9, 17 , LP982−E2, 5, 6, FC−SW CLARiiON
IBM xSeries: x336 (8837)78,x346 (8840)78, R21, SP116; PCI−X 8, 9, 17 AX100
x3550 (7978), x3650 (7979), x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP116
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
88 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4, 31 See10
x3755 (8877) [x86] Enterprise Edition: Express, LP1050−E2, 5, 6, 8, 9, 17 , LP982−E2, 5, 6, FC−SW CLARiiON
R21, SP116; PCI−X 8, 9, 17 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
89 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 30, LP1050−E2, FC−AL, EMC Y3, 4 See10
x3755 (8877) [x86] Enterprise Edition: Express, 5, 6, 8, 9, LP1150−E2, 8, 9, 19, 23, 30 , FC−SW CLARiiON
R21, SP116; PCI−X LP982−E2, 5, 6, 8, 9 , LPe1150−E2, 8, 9, 19, AX100
30, 35
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
90 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 7, 8, 9 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, LP1050Ex−E2, 6, 7, 8, 9, 19 , LP982−E2, 5, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP116; PCI−X 6, 7, 8, 9, LPe1150−E2, 7, 8, 9, 19, 35 AX100
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x86] Standard Edition: R21,
SR2500/S5000PAL; SP116
Samsung ZSS132
91 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 5, 6, 8, 9, 17, 19 , FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express, LPe1150−E2, 8, 9, 17, 19, 30, 35 FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP116; PCI−X AX100
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x86] Standard Edition: R21,
SR4850HW4/SR6850HW4; SP116
Lenovo SureServer: R630 G5, R650, R650
G5, T650
92 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 5, 6, 8, 9, 17, 19 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, LPe1150−E2, 8, 9, 17, 19, 30, 35 FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP116; PCI−X AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x86] Standard Edition: R21,
Lenovo SureServer: R630 G5, R650, R650 SP116
G5, T650

11/02/2006 39 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
93 HPQ Proliant ML350(G4)18 Microsoft Windows 2003 PCI HPQ: AB429A/FC1143 (QLA2460)2, 13, FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, 19, 20, AE369A/FC1243 (QLA2462)2, 13, FC−SW CLARiiON
R21, SP116; PCI−X 19, 20 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
94 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3, 31
[x86] Enterprise Edition: Express, 108 FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
95 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 13, 14, 15, 19 FC−AL, EMC Y3
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
96 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 13, 14, 15, 19 FC−AL, EMC Y3, 4, See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON Y3, 4, 31
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
97 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 13, 14, 15, 19 FC−AL, EMC Y3, 4, See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON Y3, 4, 31
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
98 IBM xSeries: x336 (8837)78, x346 (8840)78, Microsoft Windows 2003 PCI IBM: 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
x3550 (7978), x3650 (7979) [x86] Enterprise Edition: Express, 108, 24P0960 (QLA2340)2, 13, 14, 15, 29, FC−SW CLARiiON
R21, SP116; PCI−X 62 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
99 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)2, 19, 20, 29, 92 , FC−AL, EMC Y3, 4 See11
x3755 (8877) [x86] Enterprise Edition: Express, 39M5895 (QLA2462)2, 19, 20, 29, 92 ; FC−SW CLARiiON
R21, SP116; PCI−X AX100
QLogic: QLA2340−E−SP2, 14, 15,
Microsoft Windows 2003 QLA2460−E−SP2, 15, 19, 20, 29 ,
[x86] Standard Edition: R21, QLE2460−E−SP2, 15, 19, 20, 102 ,
SP116 QLE2460−E−SP2, 15, 19, 20, 29
100 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 44, 55, 75 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP116; PCI−X AX100
AS2500;
Microsoft Windows 2003
IBM xSeries: x336 (8837)78, x346 (8840)78, [x86] Standard Edition: R21,
x3550 (7978), x3650 (7979), x3755 (8877); SP116
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
101 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 44, 55, 75 FC−AL, EMC Y3, 4, 31 See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP116; PCI−X AX100
AS2500;
Microsoft Windows 2003
IBM xSeries: x3550 (7978), x3650 (7979), [x86] Standard Edition: R21,
x3755 (8877); SP116
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
102 IBM xSeries: x336 (8837)78, x346 (8840)78, Microsoft Windows 2003 PCI QLogic QLA210−E−SP19, 41, 54, 55 FC−AL, EMC Y3, 4 See11
x3550 (7978), x3650 (7979), x3755 (8877) [x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
103 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2340−E−SP2, 13, 14, 15 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)78, x346 (8840)78, R21, SP116; PCI−X AX100
x3550 (7978), x3650 (7979), x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP116
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
104 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, 29 FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), R21, SP116; PCI−X AX100
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP116
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 40 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
105 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP2, 19, 48, 49, 50 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; R21, SP116; PCI−X AX100
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x86] Standard Edition: R21,
SP116
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
106 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 75, 77 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, QLA210−E−SP19, 41, 55, 64 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP116; PCI−X AX100
AS2500;
Microsoft Windows 2003
IBM xSeries: x3550 (7978), x3650 (7979), [x86] Standard Edition: R21,
x3755 (8877); SP116
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
107 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic: QLA210−E−SP19, 41, 54, 55 , FC−AL, EMC Y3, 4, 31 See11
x3755 (8877) [x86] Enterprise Edition: Express, QLA2340−E−SP2, 13, 14, 15 FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
108 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4, 12 See11
[x86] Enterprise Edition: Express, QLA2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, R21, SP116; PCI−X AX100
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M, Microsoft Windows 2003
SR4850HW4/SR6850HW4; [x86] Standard Edition: R21,
SP116
Lenovo SureServer: R630 G5, R650, R650
G5, T650
109 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP2, 14, 27, 28 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, QLE2360−E−SP2, 27, 28, 40 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP116; PCI−X QLE2460−E−SP2, 19, 20, 27, 28 AX100
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x86] Standard Edition: R21,
SR2500/S5000PAL; SP116
Samsung ZSS132
110 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 50 , FC−AL, EMC Y3, 4, 12 See11
[x86] Enterprise Edition: Express, QLE2360−E−SP2, 29, 38, 39, 40 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP116; PCI−X QLE2460−E−SP2, 13, 15, 19, 20, 29 AX100
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x86] Standard Edition: R21,
SR4850HW4/SR6850HW4; SP116
Lenovo SureServer: R630 G5, R650, R650
G5, T650
111 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 50 , FC−AL, EMC Y3, 4, 31 See11
[x86] Enterprise Edition: Express, QLE2360−E−SP2, 29, 38, 39, 40 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP116; PCI−X QLE2460−E−SP2, 13, 15, 19, 20, 29 AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x86] Standard Edition: R21,
Lenovo SureServer: R630 G5, R650, R650 SP116
G5, T650
112 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 29, 38, 39, 40 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, QLE2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP116; PCI−X AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x86] Standard Edition: R21,
Lenovo SureServer: R630 G5, R650, R650 SP116
G5, T650
113 IBM xSeries: x346 (8840)78, x3550 (7978), Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 29, 38, 40 , FC−AL, EMC Y3, 4 See11
x3650 (7979), x3755 (8877) [x86] Enterprise Edition: Express, QLE2360−E−SP2, 38, 40, 102 FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
114 Dell PowerEdge 6850 Microsoft Windows 2003 PCI−X Dell 2362M27, 28, 90, 91 FC−AL, EMC Y3
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116

11/02/2006 41 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
115 Dell PowerEdge 1855 Microsoft Windows 2003 PCI−X Dell: 2342M2, 14, 27, 28 , LPe1105−M7, 9, FC−AL, EMC Y3
[x86] Enterprise Edition: 19, 34, 35 , QME246219, 27, 28, 36 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
116 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex LP1150−E2, 7, 8, 9, 19, 23, 32 FC−AL, EMC Y3, 4 See10
2650, 4600, 6600, 6650 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
117 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex: LP101−E2, 6, 7, 9, 32 , FC−AL, EMC Y3, 4 See10
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86] Enterprise Edition: LP1050−E2, 5, 6, 7, 8, 9 , LP982−E2, 5, 6, 7, FC−SW CLARiiON
6850 R21, SP116; 8, 9 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
118 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
SH4500; [x86] Enterprise Edition: LP1050−E2, 5, 6, 8, 9, 17 , LP1150−E2, 8, 9, FC−SW CLARiiON
R21, SP116; 17, 19, 23, 30 , LP982−E2, 5, 6, 8, 9, 17 AX100
HPQ Proliant: BL40p, DL360(G3)18,
DL360(G4)18, DL56018, DL74018, DL760 Microsoft Windows 2003
(G2)18, DL76018, ML570(G2)18; [x86] Standard Edition: R21,
SP116
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
119 IBM xSeries x3850/x366 (8863)61 Microsoft Windows 2003 PCI−X Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4, 31 See10
[x86] Enterprise Edition: LP1050−E2, 5, 6, 8, 9, 17 , LP982−E2, 5, 6, FC−SW CLARiiON
R21, SP116; 8, 9, 17 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
120 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X Emulex: LP1050Ex−E2, 5, 6, 8, 9, 17, 19 , FC−AL, EMC Y3, 4, See10
[x86] Enterprise Edition: LPe111−E2, 7, 9, 19, 46, 60 , LPe1150−E2, FC−SW CLARiiON Y3, 4, 12
R21, SP116; 8, 9, 17, 19, 30, 35 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
121 NEC Express 5800: 140Hf, 140Re−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E2, 7, 9, 19, 46, 60 , FC−AL, EMC Y3
[x86] Enterprise Edition: LPe1150−E7, 9, 19, 32, 35 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
122 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E2, 7, 9, 19, 46, 60 , FC−AL, EMC Y3, 4, 84 See10, 11
[x86] Enterprise Edition: LPe1150−E7, 9, 19, 32, 35 ; FC−SW CLARiiON
R21, SP116; AX100
NEC N8190−120 (LP1050)2, 6, 7, 8, 9, 32,
Microsoft Windows 2003 33
[x86] Standard Edition: R21,
SP116
123 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ AE311A/FC1142SR (QLE2460)2, FC−AL, EMC Y3, 31
[x86] Enterprise Edition: 13, 15, 19, 20, 69 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
124 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86] Enterprise Edition: for HP Proliant BL25p/BL45p FC−SW CLARiiON
R21, SP116; 381881−B212, 13, 15, 29, 87 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
125 HPQ Proliant: DL360(G3)18, DL360(G4)18, Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)2, 6, 8, 9, 17, 30 , FC−AL, EMC Y3
DL56018, DL74018, DL760 (G2)18, DL76018, [x86] Enterprise Edition: A7388A (LP1050)2, 6, 8, 9, 17, 30 , FC−SW CLARiiON
ML570(G2)18 R21, SP116; AD167A/FC2143 (LP1150)8, 9, 17, 19, 30, AX100
129, FCA2214 (QLA2340)2, 13, 14, 15, 29 ,
Microsoft Windows 2003 FCA2408 (LP982)2, 6, 8, 9, 17, 19, 30
[x86] Standard Edition: R21,
SP116
126 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, Y3,
[x86] Enterprise Edition: 17, 19, 30, 35 , AE311A/FC1142SR FC−SW CLARiiON 12
R21, SP116; (QLE2460)2, 13, 15, 19, 20, 69 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116

11/02/2006 42 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
127 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 13, FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: 19, 20, AE369A/FC1243 (QLA2462)2, 13, FC−SW CLARiiON
R21, SP116; 19, 20; AX100
Microsoft Windows 2003 QLogic: QLE220−E−SP2, 19, 48, 49, 50 ,
[x86] Standard Edition: R21, QLE2360−E−SP2, 29, 38, 39, 40 ,
SP116 QLE2460−E−SP2, 13, 15, 19, 20, 29
128 IBM xSeries x3850/x366 (8863)61 Microsoft Windows 2003 PCI−X IBM 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3, 31
[x86] Enterprise Edition: 108 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
129 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
[x86] Enterprise Edition: 108, 24P0960 (QLA2340)2, 13, 14, 15, 29, FC−SW CLARiiON
R21, SP116; 62 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
130 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 39M5894 (QLA2460)2, 19, 20, 29, 92 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: 39M5895 (QLA2462)2, 19, 20, 29, 92 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
131 NEC Express 5800: 110Rg−1, 120Lh, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)2, 6, 7, 8, 9, 32, FC−AL, EMC Y3
120Re−1, 120Rg−2, 180Re−3 [x86] Enterprise Edition: 33 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
132 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)2, 6, 7, 8, 9, 32, FC−AL, EMC Y3, 4 See10
120Ri−2, 140Hf, 140Re−4 [x86] Enterprise Edition: 33 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
133 NEC Express 5800: 120Rf−1, 120Rh−2 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)2, 6, 7, 8, 9, 32, FC−AL, EMC Y3, 4
[x86] Enterprise Edition: 33 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
134 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP2, 13, 14, 15 FC−AL, EMC Y3, 4, 12 See11
[x86] Enterprise Edition: FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP116; AX100
NF520;
Microsoft Windows 2003
Samsung ZSS150 [x86] Standard Edition: R21,
SP116
135 Fujitsu Siemens Primergy RX200 Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP2, 14, 59 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
136 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC Y3, 4, 12 See11
[x86] Enterprise Edition: 29 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP116; AX100
NF520;
Microsoft Windows 2003
Samsung ZSS150; [x86] Standard Edition: R21,
Sun: x4100, x4200 SP116
137 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 15, 19, 20, 102 FC−AL, EMC Y3, 4 See11
2650, 4600, 6600, 6650; [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Sun: x4100, x4200
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
138 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 15, 19, 20, 29 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
139 Digital Henge INNO SH4500; Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 41, 42, 44, 55, FC−AL, EMC Y3, 4 See11
HPQ Proliant: BL40p, DL360(G3)18, [x86] Enterprise Edition: 75, QLA210−E−SP19, 41, 54, 55 FC−SW CLARiiON
DL360(G4)18, DL56018, DL74018, DL760 R21, SP116; AX100
(G2)18, DL76018, ML570(G2)18;
Microsoft Windows 2003
IBM xSeries: x235, x255, x360, x365, x440; [x86] Standard Edition: R21,
SP116
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun: V20z, V40z, x4100, x4200

11/02/2006 43 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
140 IBM xSeries x3850/x366 (8863)61 Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 41, 42, 44, 55, FC−AL, EMC Y3, 4, 31 See11
[x86] Enterprise Edition: 75, QLA210−E−SP19, 41, 54, 55 , FC−SW CLARiiON
R21, SP116; QLA2340−E−SP2, 13, 14, 15 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
141 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 41, 75, 77 , FC−AL, EMC Y3, 4 See11
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86] Enterprise Edition: QLA210−E−SP19, 41, 55, 64 , FC−SW CLARiiON
6850 R21, SP116; QLA2340−E−SP2, 14, 27, 28 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
142 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4 See11
SH4500; [x86] Enterprise Edition: QLA2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON
R21, SP116; AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)18, Microsoft Windows 2003
DL360(G4)18, DL56018, DL74018, DL760 [x86] Standard Edition: R21,
(G2)18, DL76018, ML570(G2)18; SP116
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
143 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X QLogic: QLE220−E−SP2, 19, 48, 49, 50 , FC−AL, EMC Y3, 4, 12, See11
[x86] Enterprise Edition: QLE2360−E−SP2, 29, 38, 39, 40 , FC−SW CLARiiON Y3, 4, 31
R21, SP116; QLE2460−E−SP2, 13, 15, 19, 20, 29 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
144 IBM xSeries x3800/x260 (8865)61 Microsoft Windows 2003 PCI−X63 Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4, 31 See10
[x86] Enterprise Edition: LP1050−E2, 5, 6, 8, 9, 17 , LP982−E2, 5, 6, FC−SW CLARiiON
R21, SP116; 8, 9, 17 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
145 IBM xSeries: x3800/x260 (8865)61, Microsoft Windows 2003 PCI−X63 Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
x3950/x3950E/x460 (8872, 8874)61 [x86] Enterprise Edition: LP1050−E2, 5, 6, 8, 9, 17 , LP982−E2, 5, 6, FC−SW CLARiiON
R21, SP116; 8, 9, 17 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
146 IBM xSeries x3800/x260 (8865)61 Microsoft Windows 2003 PCI−X63 IBM 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3, 31
[x86] Enterprise Edition: 108 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
147 IBM xSeries: x3800/x260 (8865)61, Microsoft Windows 2003 PCI−X63 IBM: 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
x3950/x3950E/x460 (8872, 8874)61 [x86] Enterprise Edition: 108, 24P0960 (QLA2340)2, 13, 14, 15, 29, FC−SW CLARiiON
R21, SP116; 62 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
148 IBM xSeries x3800/x260 (8865)61 Microsoft Windows 2003 PCI−X63 QLogic QLA2340−E−SP2, 13, 14, 15 FC−AL, EMC Y3, 4, 31 See11
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
149 IBM xSeries: x3800/x260 (8865)61, Microsoft Windows 2003 PCI−X63 QLogic QLA2340−E−SP2, 13, 14, 15 FC−AL, EMC Y3, 4 See11
x3950/x3950E/x460 (8872, 8874)61 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
150 HPQ Proliant BL20p (G2) Microsoft Windows 2003 PCI−X71 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86] Enterprise Edition: for HP Proliant BL20p (G2) FC−SW CLARiiON
R21, SP116; 300874−B212, 13, 15, 29, 72 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
151 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X71 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86] Enterprise Edition: for HP Proliant BL25p/BL45p FC−SW CLARiiON
R21, SP116; 381881−B212, 13, 15, 29, 87 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116

11/02/2006 44 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
152 HPQ Proliant BL30p Microsoft Windows 2003 PCI−X71 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86] Enterprise Edition: for HP Proliant BL30p/BL35p FC−SW CLARiiON
R21, SP116; 354054−B212, 28, 72 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
153 HPQ Proliant BL20p: (G3), (G4) Microsoft Windows 2003 PCI−X71 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86] Enterprise Edition: for HP Proliant BL20p (G3) FC−SW CLARiiON
R21, SP116; 361426−B212, 13, 15, 29, 72 , AX100
Emulex−based BL20p (G3) Fibre
Microsoft Windows 2003 Channel Mezzanine HBA −
[x86] Standard Edition: R21, 394757−B212, 9, 17, 30, 73, 74
SP116
154 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X82 Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: LP1050−E2, 5, 6, 8, 9, 17 , LP1150−E2, 8, 9, FC−SW CLARiiON
R21, SP116; 17, 19, 23, 30 , LP982−E2, 5, 6, 8, 9, 17 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
155 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X82 QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4, See11
[x86] Enterprise Edition: QLA2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON Y3, 4, 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
156 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M2, 14, 27, 28 , LPe1105−M7, 9, FC−AL, EMC Y3
[x86] Enterprise Edition: Express, 19, 34, 35, QME246219, 27, 28, 36 FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
157 HPQ Proliant DL380(G4)18 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E2, 5, 6, 8, 9, 17, 19 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
158 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LP1150−E2, 8, 9, 17, 19, 23, 30 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
159 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E2, 7, 9, 19, 46, 60 FC−AL, EMC Y3, 4 See10
HPQ Proliant DL380(G4)18 [x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
160 HPQ Proliant: DL380(G4)18, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E2, 8, 9, 17, 19, 30, 35 FC−AL, EMC Y3, 4 See10
DL580(G4) [x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
161 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E2, 8, 9, 17, 19, 30, 35 FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
162 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E2, 9, 19, 30, 95 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
163 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E2, 7, 9, 19, 46, 60 , FC−AL, EMC Y3, 4, 12 See10
[x86] Enterprise Edition: Express, LPe1150−E2, 9, 19, 30, 95 FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
164 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3
[x86] Enterprise Edition: Express, 17, 19, 30, 35 , AD167A/FC2143 FC−SW CLARiiON
R21, SP116; PCI−X (LP1150)8, 9, 17, 19, 30, 129 , AX100
AE311A/FC1142SR (QLE2460)2, 13, 15,
Microsoft Windows 2003 19, 20, 69
[x86] Standard Edition: R21,
SP116
165 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, 12
[x86] Enterprise Edition: Express, 17, 19, 30, 35 , AE311A/FC1142SR FC−SW CLARiiON
R21, SP116; PCI−X (QLE2460)2, 13, 15, 19, 20, 69 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116

11/02/2006 45 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
166 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 13, FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, 19, 20, AE369A/FC1243 (QLA2462)2, 13, FC−SW CLARiiON
R21, SP116; PCI−X 19, 20; AX100
Microsoft Windows 2003 QLogic QLA2460−E−SP2, 13, 15, 19, 20,
[x86] Standard Edition: R21, 29
SP116
167 HPQ Proliant DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP2, 19, 48, 49, 50 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
168 HPQ Proliant: DL380(G4)18, DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP2, 29, 38, 39, 40 FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
169 HPQ Proliant: DL380(G4)18, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC Y3, 4 See11
DL580(G3)18, DL580(G4) [x86] Enterprise Edition: Express, 29 FC−SW CLARiiON
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
170 HPQ Proliant: DL380(G5), DL580(G3)18, Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC Y3, 4, 12, See11
DL580(G4) [x86] Enterprise Edition: Express, 29 FC−SW CLARiiON Y3, 4, 31
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
171 HPQ Proliant DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic: QLE220−E−SP2, 19, 48, 49, 50 , FC−AL, EMC Y3, 4, 12, See11
[x86] Enterprise Edition: Express, QLE2360−E−SP2, 29, 38, 39, 40 FC−SW CLARiiON Y3, 4, 31
R21, SP116; PCI−X AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
172 Fujitsu Siemens Primergy: RX600, TX600 Microsoft Windows 2003 PCI, Emulex LP1050−E2, 5, 9, 76 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: PCI−X FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
173 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, Emulex: LP101−E2, 6, 7, 9, 32 , FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: PCI−X LP1050−E2, 5, 6, 7, 8, 9 , LP982−E2, 5, 6, 7, FC−SW CLARiiON
R21, SP116; 8, 9 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
174 HPQ Proliant: DL14518, DL380(G2)18, Microsoft Windows 2003 PCI, Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4 See10
DL380(G3)18, DL380(G4)18, DL38018, [x86] Enterprise Edition: PCI−X LP1050−E2, 5, 6, 8, 9, 17 , LP1150−E2, 8, 9, FC−SW CLARiiON
DL38518, DL580(G2)18, DL580(G3)18, R21, SP116; 17, 19, 23, 30 , LP982−E2, 5, 6, 8, 9, 17 AX100
DL58518, ML350(G3)18, ML370(G3)18,
ML370(G4)18; Microsoft Windows 2003
[x86] Standard Edition: R21,
IBM: eServer 325 (Model 8835), xSeries x345 SP116
(8670), xSeries x445 (8870);
Samsung SS140
175 HPQ Proliant: DL14518, DL380(G2)18, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)2, 6, 8, 9, 17, 30 , FC−AL, EMC Y3
DL380(G3)18, DL380(G4)18, DL38018, [x86] Enterprise Edition: PCI−X A7388A (LP1050)2, 6, 8, 9, 17, 30 , FC−SW CLARiiON
DL38518, DL580(G2)18, DL58518, R21, SP116; AD167A/FC2143 (LP1150)8, 9, 17, 19, 30, AX100
ML350(G3)18, ML370(G3)18, ML370(G4)18 129, FCA2214 (QLA2340)2, 13, 14, 15, 29 ,
Microsoft Windows 2003 FCA2408 (LP982)2, 6, 8, 9, 17, 19, 30
[x86] Standard Edition: R21,
SP116
176 HPQ Proliant: DL380(G4)18, DL38518, Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)2, 13, FC−AL, EMC Y3, 4 See11
DL58518, ML370(G4)18 [x86] Enterprise Edition: PCI−X 19, 20, AE369A/FC1243 (QLA2462)2, 13, FC−SW CLARiiON
R21, SP116; 19, 20 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
177 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM 19K1246 (QLA2310)2, 13, 14, 15, 29, FC−AL, EMC Y3
(8670), xSeries x445 (8870) [x86] Enterprise Edition: PCI−X 108 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
178 IBM xSeries: x345 (8670), x445 (8870) Microsoft Windows 2003 PCI, IBM 24P0960 (QLA2340)2, 13, 14, 15, 29, FC−AL, EMC Y3
[x86] Enterprise Edition: PCI−X 62 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116

11/02/2006 46 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
179 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM: 39M5894 (QLA2460)2, 19, 20, 29, 92 , FC−AL, EMC Y3, 4 See11
(8670), xSeries x445 (8870) [x86] Enterprise Edition: PCI−X 39M5895 (QLA2462)2, 19, 20, 29, 92 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
180 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP2, 14, 59 FC−AL, EMC Y3, 4 See11
TX600 [x86] Enterprise Edition: PCI−X FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
181 HPQ Proliant: DL14518, DL380(G2)18, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 41, 42, 44, 55, FC−AL, EMC Y3, 4 See11
DL380(G3)18, DL380(G4)18, DL38018, [x86] Enterprise Edition: PCI−X 75, QLA210−E−SP19, 41, 54, 55 , FC−SW CLARiiON
DL38518, DL580(G2)18, DL580(G3)18, R21, SP116; QLA2340−E−SP2, 13, 14, 15 , AX100
DL58518, ML350(G3)18, ML370(G3)18, QLA2460−E−SP2, 13, 15, 19, 20, 29
ML370(G4)18; Microsoft Windows 2003
[x86] Standard Edition: R21,
IBM: eServer 325 (Model 8835), xSeries x345 SP116
(8670), xSeries x445 (8870);
Samsung SS140
182 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 41, 75, 77 , FC−AL, EMC Y3, 4 See11
[x86] Enterprise Edition: PCI−X QLA210−E−SP19, 41, 55, 64 , FC−SW CLARiiON
R21, SP116; QLA2340−E−SP2, 14, 27, 28 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
183 Unisys ES7000/460 [32−Bit] Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86] Enterprise Edition: PCI−X 118 FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
184 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E2, 8, 9, 19, 23, 30 FC−AL, EMC Y3, 4 See10
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116;
Microsoft Windows 2003
[x86] Storage Server:
Enterprise Edition R2, R2
185 Fujitsu Siemens Primergy: RX200, RX300, Microsoft Windows 2003 PCI−X Emulex LP1050−E2, 5, 9, 76 FC−AL, EMC Y3, 4 See10
TX200, TX300 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116;
Microsoft Windows 2003
[x86] Storage: Server,
Server Enterprise Edition,
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
186 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y3
[x86] Enterprise Edition: Fibre Channel Mezzanine HBA − FC−SW CLARiiON
R21, SP116; 394588−B212, 5, 9, 73, 74 AX100
Microsoft Windows 2003
[x86]: Enterprise Edition21,
Standard Edition R21,
Standard Edition SP116,
Standard Edition21
187 HPQ Proliant: BL25p, BL30p Microsoft Windows 2003 PCI−X71 HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y3
[x86] Enterprise Edition: Fibre Channel Mezzanine HBA − FC−SW CLARiiON
R21, SP116; 394588−B212, 5, 9, 73, 74 AX100
Microsoft Windows 2003
[x86]: Enterprise Edition21,
Standard Edition R21,
Standard Edition SP116,
Standard Edition21
188 NEC Express 5800: 320Mc−R, 340Hb−R Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 25, FC−AL, EMC Y3
[x86] Enterprise Edition21 29, 37, 68 FC−SW CLARiiON
AX100
189 NEC Express 5800: 320La−R104, 320La104, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 25, FC−AL, EMC Y3
320Lb−R104, 105, 320Lb2−R, 320Lb104, 105, [x86] Enterprise Edition21 29, 37, 68, 103 FC−SW CLARiiON
320Lc, 320Lc−R, 330Ma−R104, 330Mb−R104, AX100
106, 107, 340Ha−R104, 106, 107

190 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP2, 14, 25, 29, 37, FC−AL, EMC Y3, 4 See11
320Lc−R [x86] Enterprise Edition21 68 FC−SW CLARiiON
AX100
191 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 121 FC−AL, EMC Y3
Model 300 [x86] Enterprise Edition21 FC−SW CLARiiON
AX100

11/02/2006 47 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
192 Unisys: FS1300, Libra Model 300 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86] Enterprise Edition21 111, 120 FC−SW CLARiiON
AX100
193 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/530, ES7000/540, ES7000/550, [x86] Enterprise Edition21 119 FC−SW CLARiiON
ES7000/560 [32−Bit] AX100
194 HPQ Proliant: BL460c (404664−B21), BL465c Microsoft Windows 2003 PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(403433−B21), BL465c (403434−B21), [x86] Enterprise: Edition, Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
BL465c (407234−B21), BL465c Edition R21, Edition SP1 (403621−B21)9, 46, 47 AX100
(407235−B21), BL480c (404704−B21)
195 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(416654−B21), (416655−B21), [x86] Enterprise: Edition, HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); Edition R21, Edition SP1; (403621−B21)9, 46, 47 AX100
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x86] Standard: Edition,
Edition R21, Edition SP1
196 Stratus ftServer 230065 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 43, 44 , FC−AL, EMC N See11
[x86] Standard Edition QLA210−E−SP19, 41, 43, 54 FC−SW CLARiiON
AX100
197 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403434−B21), (407234−B21), [x86] Standard Edition Express HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21); (403619−B21)53, 88, 89 AX100
HPQ Proliant BL480c (404704−B21)
198 Stratus ftServer 230065 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 44, 79 , FC−AL, EMC N See11
[x86] Standard Edition SP1 QLA210−E−SP19, 41, 54, 79 FC−SW CLARiiON
AX100
199 NEC Express 5800: 320La−R104, 320La104, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 28, FC−AL, EMC Y3
320Lb−R104, 105, 320Lb2−R, 320Lb104, 105, [x86] Standard Edition: R21, 29, 67, 68, 103 FC−SW CLARiiON
330Ma−R104, 330Mb−R104, 106, 107 , SP116 AX100
340Ha−R104, 106, 107
200 NEC Express 5800 320Lb2−R Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP2, 14, 28, 29, 67, FC−AL, EMC Y3, 4 See11
[x86] Standard Edition: R21, 68 FC−SW CLARiiON
SP116 AX100
201 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/530, ES7000/540 [x86] Standard Edition: R21, 118 FC−SW CLARiiON
SP116 AX100
202 NEC Express 5800: 320La−R104, 320La104, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 25, FC−AL, EMC Y3
320Lb−R104, 105, 320Lb2−R, 320Lb104, 105, [x86] Standard Edition21 29, 37, 68, 103 FC−SW CLARiiON
330Ma−R104, 330Mb−R104, 106, 107 , AX100
340Ha−R104, 106, 107
203 NEC Express 5800 320Lb2−R Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP2, 14, 25, 29, 37, FC−AL, EMC Y3, 4 See11
[x86] Standard Edition21 68 FC−SW CLARiiON
AX100
204 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES7000/530, ES7000/540 [x86] Standard Edition21 119 FC−SW CLARiiON
AX100
205 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(403434−B21), (407234−B21), [x86] Standard: Edition, Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21); Edition R21, Edition SP1 (403621−B21)9, 46, 47, QLogic AX100
QMH2462 4Gb FC HBA for HP c−Class
HPQ Proliant BL480c (404704−B21) Bladesystem (403619−B21)50, 88, 89
206 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E2, 8, 9, 19, 23, 30 FC−AL, EMC Y4 See10
[x86] Storage Server: FC−SW CLARiiON
Enterprise Edition R2, R2 AX100
207 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 15, 19, 20, 101 FC−AL, EMC Y3, 4, Y4 See11
[x86] Storage Server: FC−SW CLARiiON
Enterprise Edition R2, R2 AX100
208 Dell PowerVault: 750N, 755N80, 770N, 775N Microsoft Windows 2003 PCI Emulex: LP1050−E2, 6, 7, 8, 9, 70 , FC−AL, EMC N See10
[x86] Storage Server: LP1150−E2, 7, 8, 9, 19, 23, 32 FC−SW CLARiiON
Enterprise Edition SP1, SP1 AX100
209 Dell PowerVault: 750N, 755N80, 770N, 775N Microsoft Windows 2003 PCI Emulex: LP1050−E2, 5, 6, 8, 9 , FC−AL, EMC N See10
[x86] Storage: Server, LP1150−E2, 8, 9, 19, 23, 30 FC−SW CLARiiON
Server Enterprise Edition AX100
210 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E2, 8, 9, 17, 19, 23, 30 FC−AL, EMC Y3, 4, Y4 See10
[x86] Storage: Server, FC−SW CLARiiON
Server Enterprise Edition, AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
211 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 13, 15, 19, 20, FC−AL, EMC Y3, 4, Y4 See11
[x86] Storage: Server, 29 FC−SW CLARiiON
Server Enterprise Edition, AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
212 Fujitsu Siemens Primergy: RX200, RX300, Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 19, 41, 42, 44, FC−AL, EMC Y3, 4 See11
TX200, TX300 [x86] Storage: Server, 55, 75, QLA200−E−SP2, 41, 42, 44, 55, 75 , FC−SW CLARiiON
Server Enterprise Edition, QLA210−E−SP19, 41, 54, 55 AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
213 Fujitsu Siemens FibreCAT N40i Microsoft Windows 2003 PCI, Emulex LP1050−E2, 5, 6, 8, 9, 17, 96 FC−AL, EMC Y3, 4 See10
[x86] Storage: Server, PCI−X FC−SW CLARiiON
Server Enterprise Edition, AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1

11/02/2006 48 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
214 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, Emulex LP1050−E2, 5, 9, 76 FC−AL, EMC Y3, 4 See10
TX600 [x86] Storage: Server, PCI−X FC−SW CLARiiON
Server Enterprise Edition, AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
215 HPQ Proliant: DL380 Storage Server18, Microsoft Windows 2003 PCI, Emulex: LP101−E2, 6, 9, 17, 30 , FC−AL, EMC Y3, 4, Y4 See10
DL580 Storage Server18, DL585 Storage [x86] Storage: Server, PCI−X LP1050−E2, 5, 6, 8, 9, 17 , LP1150−E2, 8, 9, FC−SW CLARiiON
Server18 Server Enterprise Edition, 17, 19, 23, 30 , LP982−E2, 5, 6, 8, 9, 17 AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
216 HPQ Proliant: DL380 Storage Server18, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)2, 6, 8, 9, 17, 30 , FC−AL, EMC Y, Y3
DL580 Storage Server18, DL585 Storage [x86] Storage: Server, PCI−X A7388A (LP1050)2, 6, 8, 9, 17, 30 , FC−SW CLARiiON
Server18 Server Enterprise Edition, AD167A/FC2143 (LP1150)8, 9, 17, 19, 30, AX100
Server Enterprise Edition 129, FCA2214 (QLA2340)2, 13, 14, 15, 29 ,
R2, Server Enterprise FCA2408 (LP982)2, 6, 8, 9, 17, 19, 30
Edition SP1, Server R2,
Server SP1
217 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 19, 41, 42, 44, FC−AL, EMC Y3, 4 See11
TX600 [x86] Storage: Server, PCI−X 55, 75, QLA200−E−SP2, 41, 42, 44, 55, 75 , FC−SW CLARiiON
Server Enterprise Edition, QLA210−E−SP19, 41, 54, 55 AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
218 HPQ Proliant: DL380 Storage Server18, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 41, 42, 44, 55, FC−AL, EMC Y4 See11
DL580 Storage Server18, DL585 Storage [x86] Storage: Server, PCI−X 75, QLA210−E−SP19, 41, 54, 55 , FC−SW CLARiiON
Server18 Server Enterprise Edition, QLA2340−E−SP2, 13, 14, 15 , AX100
Server Enterprise Edition QLA2460−E−SP2, 13, 15, 19, 20, 29
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
219 HPQ Proliant: DL380 Storage Server18, Microsoft Windows 2003 PCI, QLogic: QLA2340−E−SP2, 13, 14, 15 , FC−AL, EMC Y3, 4 See11
DL580 Storage Server18, DL585 Storage [x86] Storage: Server, PCI−X QLA2460−E−SP2, 13, 15, 19, 20, 29 FC−SW CLARiiON
Server18 Server Enterprise Edition, AX100
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
220 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E2, 8, 9, 19, 23, 30 FC−AL, EMC N See10
[x86] Storage: Server, FC−SW CLARiiON
Server Enterprise Edition, AX100
Server Enterprise Edition
SP1, Server SP1
221 Dell PowerVault 745N Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 19, 41, 75, 77 , FC−AL, EMC N See11
[x86] Storage: Server, PCI−X QLA210−E−SP19, 41, 55, 64 FC−SW CLARiiON
Server Enterprise Edition, AX100
Server Enterprise Edition
SP1, Server SP1
222 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)6, 9, FC−AL, EMC N
[x86]: DataCenter R21, PCI−X 123, 125 FC−SW CLARiiON
Enterprise Edition R21, AX100
Standard Edition R21
223 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, FC−AL, EMC Y3
[x86]: DataCenter21, 111, 120 FC−SW CLARiiON
Enterprise Edition21 AX100
224 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 96, FC−AL, EMC Y3
[x86]: DataCenter21, 121 FC−SW CLARiiON
Enterprise Edition21 AX100
225 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX: (LP1050)6, 7, FC−AL, EMC Y
[x86]: Enterprise Edition 9, 109, 111, 130 , (LP1050)6, 7, 9, 109, 130 FC−SW CLARiiON
R21, Standard Edition R21 AX100
226 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 44, 55, 75 FC−AL, EMC N See11
[x86]: Enterprise Edition Express FC−SW CLARiiON
SP1, Standard Edition SP1 AX100
227 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 13, 14, 15, 19 FC−AL, EMC N See11
[x86]: Enterprise Edition Express, FC−SW CLARiiON
SP1, Standard Edition SP1 PCI−X AX100
228 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 44, 55, 75 FC−AL, EMC N See11
[x86]: Enterprise Edition Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, SP1, Standard Edition SP1 PCI−X AX100
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
229 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX: (LP1050)6, 9, FC−AL, EMC Y3
[x86]: Enterprise Edition PCI−X 122, 123, (LP1050)6, 9, 123, 124 FC−SW CLARiiON
SP116, Standard Edition AX100
SP116
230 Unisys: ES3220, ES3220L Microsoft Windows 2003 PCI, Unisys FCH752313−PCX: (LP1050)6, 9, FC−AL, EMC N
[x86]: Enterprise Edition PCI−X (LP1050)9 FC−SW CLARiiON
SP116, Standard Edition AX100
SP116

11/02/2006 49 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
231 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 43, 44, 56 FC−AL, EMC N See11
[x86]: Enterprise Edition, Express FC−SW CLARiiON
Standard Edition AX100
232 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 14, 19, 25, 37 FC−AL, EMC N See11
[x86]: Enterprise Edition, Express, FC−SW CLARiiON
Standard Edition PCI−X AX100
233 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 43, 44, 56 FC−AL, EMC N See11
[x86]: Enterprise Edition, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition PCI−X AX100
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
234 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), [x86]: Enterprise Edition, HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); Standard Edition (403619−B21)53, 88, 89 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
235 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI Emulex LP101−E2, 6, 9, 22, 24 FC−AL, EMC Y3, 4 See10
DL36018, DL58018, ML350(G2)18, ML35018, [x86]: Enterprise Edition21, FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, Standard Edition21 AX100
ML530(G3)18, ML53018, ML57018, ML75018;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
236 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI Emulex LP982−E2, 6, 8, 9, 24, 26 FC−AL, EMC Y3, 4 See10
DL36018, DL58018, ML350(G2)18, ML35018, [x86]: Enterprise Edition21, FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, Standard Edition21 AX100
ML530(G3)18, ML53018, ML57018, ML75018;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x342, x350 (6000R), x370
237 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 22, LP982−E2, 6, FC−AL, EMC Y3, 4 See10
2500, 255080, 4300, 4350, 4400, 6100, 6300, [x86]: Enterprise Edition21, 8, 9, 26 FC−SW CLARiiON
6350, 6400, 6450, 8450 Standard Edition21 AX100
238 HPQ Proliant: 850018, DL32018, Microsoft Windows 2003 PCI Emulex: LP1050−E2, 6, 8, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
DL360(G2)18, DL36018, DL380(G2)18, [x86]: Enterprise Edition21, LP1150−E2, 8, 9, 19, 22, 23, 24 FC−SW CLARiiON
DL380(G3)18, DL38018, DL58018, Standard Edition21 AX100
ML350(G2)18, ML35018, ML370(G2)18,
ML37018, ML530(G2)18, ML530(G3)18,
ML53018, ML57018, ML75018;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
239 Dell PowerEdge: 1550, 2450, 2500, 255080, Microsoft Windows 2003 PCI Emulex: LP1050−E2, 6, 8, 9, 22 , FC−AL, EMC Y3, 4 See10
4400, 6350, 6400, 645081, 8450 [x86]: Enterprise Edition21, LP1150−E2, 8, 9, 19, 22, 23 FC−SW CLARiiON
Standard Edition21 AX100
240 Fujitsu Siemens Primergy: BX60097, BX620 Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q2, 14, 19, FC−AL, EMC Y3
S2F57, BX620 S257, BX620 S3, BX62057, [x86]: Enterprise Edition21, 58, 85 FC−SW CLARiiON
BX630 (2−way), BX630 (4−way), BX630 Standard Edition21 AX100
(8−way), BX66057
241 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI HPQ: A7298A (LP982)2, 6, 8, 9, 22, 24 , FC−AL, EMC Y3
DL36018, DL380(G2)18, DL380(G3)18, [x86]: Enterprise Edition21, A7388A (LP1050)2, 6, 8, 9, 22, 24 , FC−SW CLARiiON
DL38018, DL58018, ML350(G2)18, ML35018, Standard Edition21 AD167A/FC2143 (LP1150)8, 9, 19, 22, 24, AX100
ML370(G2)18, ML37018, ML530(G2)18, 129, FCA2214 (QLA2340)2, 14, 25, 29, 37 ,
ML53018, ML57018, ML75018 FCA2408 (LP982)2, 6, 8, 9, 19, 22, 24
242 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3
x330, x335, x340 (4500R), x342, x350 [x86]: Enterprise Edition21, 108 FC−SW CLARiiON
(6000R), x370 Standard Edition21 AX100
243 IBM xSeries: x230, x240, x250, x330, x335, Microsoft Windows 2003 PCI IBM 24P0960 (QLA2340)2, 14, 25, 29, 37, FC−AL, EMC Y3
x340 (4500R), x342, x350 (6000R), x370 [x86]: Enterprise Edition21, 62 FC−SW CLARiiON
Standard Edition21 AX100
244 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)2, 19, 20, 29, 93 , FC−AL, EMC Y3, 4 See11
x330, x335, x340 (4500R), x342, x350 [x86]: Enterprise Edition21, 39M5895 (QLA2462)2, 19, 20, 29, 93 FC−SW CLARiiON
(6000R), x370 Standard Edition21 AX100
245 NEC Express 5800: 120Rd−1, 120Rf−2, Microsoft Windows 2003 PCI NEC N8190−120 (LP1050)2, 6, 8, 9, 22, FC−AL, EMC Y3
140Hd, 140Rc−4, 180Rd−4 [x86]: Enterprise Edition21, 24, 33 FC−SW CLARiiON
Standard Edition21 AX100
246 NEC Express 5800: 320La−R104, 320La104, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)2, 14, 25, FC−AL, EMC Y3
320Lb−R104, 105, 320Lb104, 105 [x86]: Enterprise Edition21, 29, 37 FC−SW CLARiiON
Standard Edition21 AX100
247 HPQ Proliant: DL32018, DL360(G2)18, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 43, 44, FC−AL, EMC Y3, 4 See11
DL36018, DL58018, ML350(G2)18, ML35018, [x86]: Enterprise Edition21, 56, QLA210−E−SP19, 41, 54, 56 , FC−SW CLARiiON
ML370(G2)18, ML37018, ML530(G2)18, Standard Edition21 QLA2340−E−SP2, 14, 25, 37 , AX100
ML530(G3)18, ML53018, ML57018, ML75018; QLA2460−E−SP2, 19, 20, 25, 29, 37
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
248 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 43, 77 , FC−AL, EMC Y3, 4 See11
2500, 255080, 4300, 4350, 4400, 6100, 6300, [x86]: Enterprise Edition21, QLA210−E−SP19, 41, 56, 64 , FC−SW CLARiiON
6350, 6400, 6450, 8450 Standard Edition21 QLA2340−E−SP2, 14, 25, 27 , AX100
QLA2460−E−SP2, 19, 20, 37, 102

11/02/2006 50 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
249 Unisys: ES3120, ES3120L, ES3140, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
ES3140L [x86]: Enterprise Edition21, 127 FC−SW CLARiiON
Standard Edition21 AX100
250 Fujitsu Siemens Primergy: RX200 S2, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 9, 19, 22, 76 FC−AL, EMC Y3, 4, See10
S2, TX600 S2 [x86]: Enterprise Edition21, Express FC−SW CLARiiON Y3, 4, 12
Standard Edition21 AX100
251 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex LPe111−E2, 9, 19, 24, 46, 60 FC−AL, EMC Y3, 4 See10
2850, 6800, 6850; [x86]: Enterprise Edition21, Express FC−SW CLARiiON
Standard Edition21 AX100
Digital Henge INNO: HR−4850, HR−6850;
Fujitsu Siemens Primergy RX300 S3;
HPQ Proliant: DL360(G4)18, DL380(G4)18,
DL580(G3)18;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
252 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex LPe111−E2, 9, 19, 24, 46, 60 FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition21 AX100
Fujitsu Siemens Primergy RX300 S3;
HPQ Proliant: DL360(G4)18, DL380(G4)18,
DL580(G3)18;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
253 Fujitsu Siemens Primergy RX300 S3 Microsoft Windows 2003 PCI Emulex LPe1150−E2, 9, 19, 22, 95 FC−AL, EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express FC−SW CLARiiON Y3, 4, 12
Standard Edition21 AX100
254 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express LP1050−E2, 6, 8, 9, 22, 24 , LP1150−E2, 8, FC−SW CLARiiON
Standard Edition21 9, 19, 22, 23, 24 , LP982−E2, 6, 8, 9, 24, 26 AX100
255 Dell PowerEdge 1950 Microsoft Windows 2003 PCI Emulex: LP1050−E2, 6, 8, 9, 22 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express LP982−E2, 6, 8, 9, 26 FC−SW CLARiiON
Standard Edition21 AX100
256 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 8, 9, 19, 22, 24 , FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express LPe1150−E2, 8, 9, 19, 22, 24, 35 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition21 AX100
HPQ Proliant: DL360(G4)18, DL380(G4)18,
DL580(G3)18;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
257 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 8, 9, 19, 22, 24 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express LPe1150−E2, 8, 9, 19, 22, 24, 35 FC−SW CLARiiON
HPQ Proliant: DL360(G4)18, DL380(G4)18, Standard Edition21 AX100
DL580(G3)18;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
258 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 8, 9, 19, 24 , FC−AL, EMC Y3, 4 See10
2850, 6800, 6850 [x86]: Enterprise Edition21, Express LPe1150−E2, 8, 9, 19, 24, 35 FC−SW CLARiiON
Standard Edition21 AX100
259 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)2, 8, 9, 19, 22, 24 FC−AL, EMC Y3, Y3,
[x86]: Enterprise Edition21, Express FC−SW CLARiiON 12
Standard Edition21 AX100
260 HPQ Proliant: DL360(G4)18, DL380(G4)18, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, Y3,
DL580(G3)18 [x86]: Enterprise Edition21, Express 19, 22, 24, 35 FC−SW CLARiiON 12
Standard Edition21 AX100
261 HPQ Proliant: DL360(G4)18, DL380(G4)18 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)2, FC−AL, EMC Y3, Y3,
[x86]: Enterprise Edition21, Express 19, 20, 25, 37, 69 FC−SW CLARiiON 12
Standard Edition21 AX100
262 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)9, 26, 33, 35, FC−AL, EMC Y3, 4 See10
120Ri−2, 140Hf, 140Re−4 [x86]: Enterprise Edition21, Express 86 FC−SW CLARiiON
Standard Edition21 AX100
263 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)9, 26, 33, 35, FC−AL, EMC Y3, 4, 84 See10, 11
[x86]: Enterprise Edition21, Express 86 FC−SW CLARiiON
Standard Edition21 AX100
264 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 43, 44, 56 FC−AL, EMC Y3, 4, 31 See11
[x86]: Enterprise Edition21, Express FC−SW CLARiiON
Standard Edition21 AX100
265 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP2, 19, 48, 49, 53 FC−AL, EMC Y3, 4 See11
2850, 6800, 6850; [x86]: Enterprise Edition21, Express FC−SW CLARiiON
Standard Edition21 AX100
Digital Henge INNO: HR−4850, HR−6850;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D

11/02/2006 51 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
266 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic QLE2360−E−SP2, 29, 40, 51, 52 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition21 AX100
NF520;
Samsung: ZSS230, ZSS230D
267 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic QLE2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express 37 FC−SW CLARiiON
IBM xSeries x3455 (7984); Standard Edition21 AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
268 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 42, 43, 44, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express 56, QLA200−E−SP2, 41, 43, 77 , FC−SW CLARiiON
Standard Edition21 QLA210−E−SP19, 41, 56, 64 , AX100
QLA2340−E−SP2, 14, 25, 27
269 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP2, 14, 25, 37 , FC−AL, EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express QLA2460−E−SP2, 19, 20, 25, 29, 37 FC−SW CLARiiON Y3, 4, 12
Standard Edition21 AX100
270 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 53 , FC−AL, EMC Y3, 4, 12 See11
[x86]: Enterprise Edition21, Express QLE2360−E−SP2, 29, 40, 51, 52 , FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition21 QLE2460−E−SP2, 19, 20, 25, 29, 37 AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
271 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 53 , FC−AL, EMC Y3, 4, 31 See11
[x86]: Enterprise Edition21, Express QLE2360−E−SP2, 29, 40, 51, 52 , FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition21 QLE2460−E−SP2, 19, 20, 25, 29, 37 AX100
NF520;
Samsung: ZSS230, ZSS230D
272 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 25, 27, 40 , FC−AL, EMC Y3, 4 See11
2850, 6800, 6850 [x86]: Enterprise Edition21, Express QLE2460−E−SP2, 19, 20, 25, 27 FC−SW CLARiiON
Standard Edition21 AX100
273 IBM xSeries x3455 (7984) Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 25, 29, 40, 51 , FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express QLE2360−E−SP2, 25, 40, 51, 102 , FC−SW CLARiiON
Standard Edition21 QLE2460−E−SP2, 19, 20, 25, 37, 102 AX100
274 IBM eServer 326m (Model 7969) Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 6, 8, 9, 19, 22 FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
275 IBM: eServer 326m (Model 7969), xSeries Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 6, 8, 9, 19, 22 FC−AL, EMC Y3, 4 See10
x3550 (7978), xSeries x3650 (7979), xSeries [x86]: Enterprise Edition21, Express, FC−SW CLARiiON
x3755 (8877) Standard Edition21 PCI−X AX100
276 Fujitsu Siemens Primergy: RX220, RX600 S3, Microsoft Windows 2003 PCI Emulex LP1050Ex−E2, 9, 19, 22, 76 FC−AL, EMC Y3, 4, See10
TX600 S3 [x86]: Enterprise Edition21, Express, FC−SW CLARiiON Y3, 4, 12
Standard Edition21 PCI−X AX100
277 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LP1150−E2, 8, 9, 19, 22, 23, 24 FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Standard Edition21 PCI−X AX100
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
278 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E2, 9, 19, 24, 46, 60 FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Standard Edition21 PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy: RX200 S3, RX220,
RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
279 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LPe111−E2, 9, 19, 24, 46, 60 FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S3, RX220, Standard Edition21 PCI−X AX100
RX600 S3, TX300 S3, TX600 S3;
IBM eServer 326m (Model 7969);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 52 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
280 Fujitsu Siemens Primergy: RX200 S3, RX220, Microsoft Windows 2003 PCI Emulex LPe1150−E2, 9, 19, 22, 95 FC−AL, EMC Y3, 4, See10
RX600 S3, TX300 S3, TX600 S3 [x86]: Enterprise Edition21, Express, FC−SW CLARiiON Y3, 4, 12
Standard Edition21 PCI−X AX100
281 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, LP1050−E2, 6, 8, 9, 22, 24 , LP982−E2, 6, 8, FC−SW CLARiiON
IBM xSeries: x336 (8837)78, x346 (8840)78, Standard Edition21 PCI−X 9, 24, 26 AX100
x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
282 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4, 31 See10
x3755 (8877) [x86]: Enterprise Edition21, Express, LP1050−E2, 6, 8, 9, 22, 24 , LP982−E2, 6, 8, FC−SW CLARiiON
Standard Edition21 PCI−X 9, 24, 26 AX100
283 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E2, 6, 9, 22, LP1150−E2, FC−AL, EMC Y3, 4 See10
x3755 (8877) [x86]: Enterprise Edition21, Express, 8, 9, 19, 22, 23 , LPe1150−E2, 8, 9, 19, 22, 35 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
284 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050−E2, 6, 8, 9, 22 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, LP982−E2, 6, 8, 9, 26 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition21 PCI−X AX100
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
285 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 8, 9, 19, 22, 24 , FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express, LPe1150−E2, 8, 9, 19, 22, 24, 35 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition21 PCI−X AX100
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
286 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 8, 9, 19, 22, 24 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, LPe1150−E2, 8, 9, 19, 22, 24, 35 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition21 PCI−X AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
287 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E2, 6, 8, 9, 19, 24 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, LPe1150−E2, 8, 9, 19, 24, 35 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition21 PCI−X AX100
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
288 HPQ Proliant ML350(G4)18 Microsoft Windows 2003 PCI HPQ: AB429A/FC1143 (QLA2460)2, 19, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, 20, 25, AE369A/FC1243 (QLA2462)2, 19, FC−SW CLARiiON
Standard Edition21 PCI−X 20, 25 AX100
289 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3, 31
[x86]: Enterprise Edition21, Express, 108 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
290 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 14, 19, 25, 37 FC−AL, EMC Y3
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
291 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 14, 19, 25, 37 FC−AL, EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON Y3, 4, 31
Standard Edition21 PCI−X AX100
292 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)2, 14, 19, 25, 37 FC−AL, EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON Y3, 4, 31
Standard Edition21 PCI−X AX100
293 IBM xSeries: x336 (8837)78, x346 (8840)78, Microsoft Windows 2003 PCI IBM: 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3
x3550 (7978), x3650 (7979) [x86]: Enterprise Edition21, Express, 108, 24P0960 (QLA2340)2, 14, 25, 29, 37, FC−SW CLARiiON
Standard Edition21 PCI−X 62 AX100
294 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)2, 19, 20, 29, 93 , FC−AL, EMC Y3, 4 See11
x3755 (8877) [x86]: Enterprise Edition21, Express, 39M5895 (QLA2462)2, 19, 20, 29, 93 ; FC−SW CLARiiON
Standard Edition21 PCI−X AX100
QLogic: QLA2340−E−SP2, 14, 37,
QLA2460−E−SP2, 19, 20, 29, 37 ,
QLE2460−E−SP2, 19, 20, 29, 37 ,
QLE2460−E−SP2, 19, 20, 37, 102
295 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 43, 44, 56 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition21 PCI−X AX100
AS2500;
IBM xSeries: x336 (8837)78, x346 (8840)78,
x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132

11/02/2006 53 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
296 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP2, 41, 42, 43, 44, 56 FC−AL, EMC Y3, 4, 31 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition21 PCI−X AX100
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
297 IBM xSeries: x336 (8837)78, x346 (8840)78, Microsoft Windows 2003 PCI QLogic QLA210−E−SP19, 41, 54, 56 FC−AL, EMC Y3, 4 See11
x3550 (7978), x3650 (7979), x3755 (8877) [x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
298 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2340−E−SP2, 14, 25, 37 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)78,x346 (8840)78, Standard Edition21 PCI−X AX100
x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
299 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, 37 FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Standard Edition21 PCI−X AX100
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
300 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP2, 19, 48, 49, 53 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Standard Edition21 PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
301 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA200−E−SP2, 41, 43, 77 , FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, QLA210−E−SP19, 41, 56, 64 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition21 PCI−X AX100
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
302 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic: QLA210−E−SP19, 41, 54, 56 , FC−AL, EMC Y3, 4, 31 See11
x3755 (8877) [x86]: Enterprise Edition21, Express, QLA2340−E−SP2, 14, 25, 37 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
303 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP2, 14, 25, 27 , FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, QLE2360−E−SP2, 25, 27, 40 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition21 PCI−X QLE2460−E−SP2, 19, 20, 25, 27 AX100
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
304 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP2, 14, 25, 37 , FC−AL, EMC Y3, 4, 12 See11
[x86]: Enterprise Edition21, Express, QLA2460−E−SP2, 19, 20, 25, 29, 37 FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, Standard Edition21 PCI−X AX100
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
305 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 53 , FC−AL, EMC Y3, 4, 12 See11
[x86]: Enterprise Edition21, Express, QLE2360−E−SP2, 29, 40, 51, 52 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition21 PCI−X QLE2460−E−SP2, 19, 20, 25, 29, 37 AX100
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 54 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
306 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP2, 19, 48, 49, 53 , FC−AL, EMC Y3, 4, 31 See11
[x86]: Enterprise Edition21, Express, QLE2360−E−SP2, 29, 40, 51, 52 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition21 PCI−X QLE2460−E−SP2, 19, 20, 25, 29, 37 AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
307 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 29, 40, 51, 52 , FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, QLE2460−E−SP2, 19, 20, 25, 29, 37 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition21 PCI−X AX100
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
308 IBM xSeries: x346 (8840)78, x3550 (7978), Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP2, 29, 40, 51 , FC−AL, EMC Y3, 4 See11
x3650 (7979), x3755 (8877) [x86]: Enterprise Edition21, Express, QLE2360−E−SP2, 40, 51, 102 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
309 Dell PowerEdge 6850 Microsoft Windows 2003 PCI−X Dell 2362M25, 27, 90, 91 FC−AL, EMC Y3
[x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
310 Dell PowerEdge 1855 Microsoft Windows 2003 PCI−X Dell: 2342M2, 14, 25, 27 , LPe1105−M9, 19, FC−AL, EMC Y3
[x86]: Enterprise Edition21, 24, 34, 35 , QME246219, 25, 27, 36 FC−SW CLARiiON
Standard Edition21 AX100
311 Fujitsu Siemens Primergy: RX200, RX300, Microsoft Windows 2003 PCI−X Emulex LP1050−E2, 9, 22, 76 FC−AL, EMC Y3, 4 See10
TX200, TX300 [x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
312 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex LP1150−E2, 8, 9, 19, 22, 23 FC−AL, EMC Y3, 4 See10
2650, 4600, 6600, 6650; [x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
Sun: x4100, x4200
313 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
SH4500; [x86]: Enterprise Edition21, LP1050−E2, 6, 8, 9, 22, 24 , LP1150−E2, 8, FC−SW CLARiiON
Standard Edition21 9, 19, 22, 23, 24 , LP982−E2, 6, 8, 9, 24, 26 AX100
HPQ Proliant: BL40p, DL360(G3)18,
DL360(G4)18, DL56018, DL74018, DL760
(G2)18, DL76018, ML570(G2)18;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
314 IBM xSeries x3850/x366 (8863)61 Microsoft Windows 2003 PCI−X Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4, 31 See10
[x86]: Enterprise Edition21, LP1050−E2, 6, 8, 9, 22, 24 , LP982−E2, 6, 8, FC−SW CLARiiON
Standard Edition21 9, 24, 26 AX100
315 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex: LP101−E2, 6, 9, 22, LP1050−E2, FC−AL, EMC Y3, 4 See10
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86]: Enterprise Edition21, 6, 8, 9, 22 , LP982−E2, 6, 8, 9, 26 FC−SW CLARiiON
6850 Standard Edition21 AX100
316 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X Emulex: LP1050Ex−E2, 6, 8, 9, 19, 22, 24 , FC−AL, EMC Y3, 4, See10
[x86]: Enterprise Edition21, LPe111−E2, 9, 19, 24, 46, 60 , FC−SW CLARiiON Y3, 4, 12
Standard Edition21 LPe1150−E2, 8, 9, 19, 22, 24, 35 AX100
317 NEC Express 5800: 140Hf, 140Re−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E2, 9, 19, 24, 46, 60 , FC−AL, EMC Y3
[x86]: Enterprise Edition21, LPe1150−E9, 19, 26, 35, 86 FC−SW CLARiiON
Standard Edition21 AX100
318 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E2, 9, 19, 24, 46, 60 , FC−AL, EMC Y3, 4, 84 See10, 11
[x86]: Enterprise Edition21, LPe1150−E9, 19, 26, 35, 86 ; FC−SW CLARiiON
Standard Edition21 AX100
NEC N8190−120 (LP1050)2, 6, 8, 9, 22,
24, 33

319 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ AE311A/FC1142SR (QLE2460)2, FC−AL, EMC Y3, 31
[x86]: Enterprise Edition21, 19, 20, 25, 37, 69 FC−SW CLARiiON
Standard Edition21 AX100
320 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86]: Enterprise Edition21, for HP Proliant BL25p/BL45p FC−SW CLARiiON
Standard Edition21 381881−B212, 25, 29, 37, 87 AX100
321 HPQ Proliant: DL360(G3)18, DL360(G4)18, Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)2, 6, 8, 9, 22, 24 , FC−AL, EMC Y3
DL56018, DL74018, DL760 (G2)18, DL76018, [x86]: Enterprise Edition21, A7388A (LP1050)2, 6, 8, 9, 22, 24 , FC−SW CLARiiON
ML570(G2)18 Standard Edition21 AD167A/FC2143 (LP1150)8, 9, 19, 22, 24, AX100
129, FCA2214 (QLA2340)2, 14, 25, 29, 37 ,
FCA2408 (LP982)2, 6, 8, 9, 19, 22, 24
322 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, Y3,
[x86]: Enterprise Edition21, 19, 22, 24, 35 , AE311A/FC1142SR FC−SW CLARiiON 12
Standard Edition21 (QLE2460)2, 19, 20, 25, 37, 69 AX100
323 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 19, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, 20, 25, AE369A/FC1243 (QLA2462)2, 19, FC−SW CLARiiON
Standard Edition21 20, 25; AX100
QLogic: QLE220−E−SP2, 19, 48, 49, 53 ,
QLE2360−E−SP2, 29, 40, 51, 52 ,
QLE2460−E−SP2, 19, 20, 25, 29, 37

11/02/2006 55 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
324 IBM xSeries x3850/x366 (8863)61 Microsoft Windows 2003 PCI−X IBM 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3, 31
[x86]: Enterprise Edition21, 108 FC−SW CLARiiON
Standard Edition21 AX100
325 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3
[x86]: Enterprise Edition21, 108, 24P0960 (QLA2340)2, 14, 25, 29, 37, FC−SW CLARiiON
Standard Edition21 62 AX100
326 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 39M5894 (QLA2460)2, 19, 20, 29, 93 , FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, 39M5895 (QLA2462)2, 19, 20, 29, 93 FC−SW CLARiiON
Standard Edition21 AX100
327 NEC Express 5800: 110Rg−1, 120Lh, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)2, 6, 8, 9, 22, FC−AL, EMC Y3
120Re−1, 120Rg−2, 180Re−3 [x86]: Enterprise Edition21, 24, 33 FC−SW CLARiiON
Standard Edition21 AX100
328 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)2, 6, 8, 9, 22, FC−AL, EMC Y3, 4 See10
120Ri−2, 140Hf, 140Re−4 [x86]: Enterprise Edition21, 24, 33 FC−SW CLARiiON
Standard Edition21 AX100
329 NEC Express 5800: 120Rf−1, 120Rh−2 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)2, 6, 8, 9, 22, FC−AL, EMC Y3, 4
[x86]: Enterprise Edition21, 24, 33 FC−SW CLARiiON
Standard Edition21 AX100
330 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP2, 14, 25, 37 FC−AL, EMC Y3, 4, 12 See11
[x86]: Enterprise Edition21, FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition21 AX100
NF520;
Samsung ZSS150
331 Fujitsu Siemens Primergy RX200 Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP2, 14, 85 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
332 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4, 12 See11
[x86]: Enterprise Edition21, 37 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition21 AX100
NF520;
Samsung ZSS150;
Sun: x4100, x4200
333 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 29, 37 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
334 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP2, 19, 20, 37, 102 FC−AL, EMC Y3, 4 See11
2650, 4600, 6600, 6650; [x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
Sun: x4100, x4200
335 Digital Henge INNO SH4500; Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 41, 42, 43, 44, FC−AL, EMC Y3, 4 See11
HPQ Proliant: BL40p, DL360(G3)18, [x86]: Enterprise Edition21, 56, QLA210−E−SP19, 41, 54, 56 FC−SW CLARiiON
DL360(G4)18, DL56018, DL74018, DL760 Standard Edition21 AX100
(G2)18, DL76018, ML570(G2)18;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun: V20z, V40z, x4100, x4200
336 IBM xSeries x3850/x366 (8863)61 Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 41, 42, 43, 44, FC−AL, EMC Y3, 4, 31 See11
[x86]: Enterprise Edition21, 56, QLA210−E−SP19, 41, 54, 56 , FC−SW CLARiiON
Standard Edition21 QLA2340−E−SP2, 14, 25, 37 AX100
337 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP2, 41, 43, 77 , FC−AL, EMC Y3, 4 See11
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86]: Enterprise Edition21, QLA210−E−SP19, 41, 56, 64 , FC−SW CLARiiON
6850 Standard Edition21 QLA2340−E−SP2, 14, 25, 27 AX100
338 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X QLogic: QLA2340−E−SP2, 14, 25, 37 , FC−AL, EMC Y3, 4 See11
SH4500; [x86]: Enterprise Edition21, QLA2460−E−SP2, 19, 20, 25, 29, 37 FC−SW CLARiiON
Standard Edition21 AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)18,
DL360(G4)18, DL56018, DL74018, DL760
(G2)18, DL76018, ML570(G2)18;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
339 HPQ Proliant DL360(G4)18 Microsoft Windows 2003 PCI−X QLogic: QLE220−E−SP2, 19, 48, 49, 53 , FC−AL, EMC Y3, 4, 12, See11
[x86]: Enterprise Edition21, QLE2360−E−SP2, 29, 40, 51, 52 , FC−SW CLARiiON Y3, 4, 31
Standard Edition21 QLE2460−E−SP2, 19, 20, 25, 29, 37 AX100
340 IBM xSeries x3800/x260 (8865)61 Microsoft Windows 2003 PCI−X63 Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4, 31 See10
[x86]: Enterprise Edition21, LP1050−E2, 6, 8, 9, 22, 24 , LP982−E2, 6, 8, FC−SW CLARiiON
Standard Edition21 9, 24, 26 AX100

11/02/2006 56 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
341 IBM xSeries: x3800/x260 (8865)61, Microsoft Windows 2003 PCI−X63 Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
x3950/x3950E/x460 (8872, 8874)61 [x86]: Enterprise Edition21, LP1050−E2, 6, 8, 9, 22, 24 , LP982−E2, 6, 8, FC−SW CLARiiON
Standard Edition21 9, 24, 26 AX100
342 IBM xSeries x3800/x260 (8865)61 Microsoft Windows 2003 PCI−X63 IBM 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3, 31
[x86]: Enterprise Edition21, 108 FC−SW CLARiiON
Standard Edition21 AX100
343 IBM xSeries: x3800/x260 (8865)61, Microsoft Windows 2003 PCI−X63 IBM: 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3
x3950/x3950E/x460 (8872, 8874)61 [x86]: Enterprise Edition21, 108, 24P0960 (QLA2340)2, 14, 25, 29, 37, FC−SW CLARiiON
Standard Edition21 62 AX100
344 IBM xSeries x3800/x260 (8865)61 Microsoft Windows 2003 PCI−X63 QLogic QLA2340−E−SP2, 14, 25, 37 FC−AL, EMC Y3, 4, 31 See11
[x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
345 IBM xSeries: x3800/x260 (8865)61, Microsoft Windows 2003 PCI−X63 QLogic QLA2340−E−SP2, 14, 25, 37 FC−AL, EMC Y3, 4 See11
x3950/x3950E/x460 (8872, 8874)61 [x86]: Enterprise Edition21, FC−SW CLARiiON
Standard Edition21 AX100
346 HPQ Proliant BL20p (G2) Microsoft Windows 2003 PCI−X71 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86]: Enterprise Edition21, for HP Proliant BL20p (G2) FC−SW CLARiiON
Standard Edition21 300874−B212, 25, 29, 37, 72 AX100
347 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X71 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86]: Enterprise Edition21, for HP Proliant BL25p/BL45p FC−SW CLARiiON
Standard Edition21 381881−B212, 25, 29, 37, 87 AX100
348 HPQ Proliant BL30p Microsoft Windows 2003 PCI−X71 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86]: Enterprise Edition21, for HP Proliant BL30p/BL35p FC−SW CLARiiON
Standard Edition21 354054−B212, 25, 72 AX100
349 HPQ Proliant BL20p: (G3), (G4) Microsoft Windows 2003 PCI−X71 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y3
[x86]: Enterprise Edition21, for HP Proliant BL20p (G3) FC−SW CLARiiON
Standard Edition21 361426−B212, 25, 29, 37, 72 , AX100
Emulex−based BL20p (G3) Fibre
Channel Mezzanine HBA −
394757−B212, 9, 22, 24, 73, 74
350 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X82 Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, LP1050−E2, 6, 8, 9, 22, 24 , LP1150−E2, 8, FC−SW CLARiiON
Standard Edition21 9, 19, 22, 23, 24 , LP982−E2, 6, 8, 9, 24, 26 AX100
351 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X82 QLogic: QLA2340−E−SP2, 14, 25, 37 , FC−AL, EMC Y3, 4, See11
[x86]: Enterprise Edition21, QLA2460−E−SP2, 19, 20, 25, 29, 37 FC−SW CLARiiON Y3, 4, 12
Standard Edition21 AX100
352 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M2, 14, 25, 27 , LPe1105−M9, 19, FC−AL, EMC Y3
[x86]: Enterprise Edition21, Express, 24, 34, 35, QME246219, 25, 27, 36 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
353 HPQ Proliant DL380(G4)18 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E2, 6, 8, 9, 19, 22, 24 FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
354 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LP1150−E2, 8, 9, 19, 22, 23, 24 FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
355 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E2, 9, 19, 24, 46, 60 FC−AL, EMC Y3, 4 See10
HPQ Proliant DL380(G4)18 [x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
356 HPQ Proliant: DL380(G4)18, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E2, 8, 9, 19, 22, 24, 35 FC−AL, EMC Y3, 4 See10
DL580(G4) [x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
357 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E2, 8, 9, 19, 22, 24, 35 FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
358 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E2, 9, 19, 22, 95 FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
359 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E2, 9, 19, 24, 46, 60 , FC−AL, EMC Y3, 4, 12 See10
[x86]: Enterprise Edition21, Express, LPe1150−E2, 9, 19, 22, 95 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
360 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3
[x86]: Enterprise Edition21, Express, 19, 22, 24, 35 , AD167A/FC2143 FC−SW CLARiiON
Standard Edition21 PCI−X (LP1150)8, 9, 19, 22, 24, 129 , AX100
AE311A/FC1142SR (QLE2460)2, 19, 20,
25, 37, 69

361 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)8, 9, FC−AL, EMC Y3, 12
[x86]: Enterprise Edition21, Express, 19, 22, 24, 35 , AE311A/FC1142SR FC−SW CLARiiON
Standard Edition21 PCI−X (QLE2460)2, 19, 20, 25, 37, 69 AX100
362 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 19, FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, 20, 25, AE369A/FC1243 (QLA2462)2, 19, FC−SW CLARiiON
Standard Edition21 PCI−X 20, 25; AX100
QLogic QLA2460−E−SP2, 19, 20, 25, 29,
37

363 HPQ Proliant DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP2, 19, 48, 49, 53 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
364 HPQ Proliant: DL380(G4)18, DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP2, 29, 40, 51, 52 FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, Express, FC−SW CLARiiON
Standard Edition21 PCI−X AX100
365 HPQ Proliant: DL380(G4)18, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4 See11
DL580(G3)18, DL580(G4) [x86]: Enterprise Edition21, Express, 37 FC−SW CLARiiON
Standard Edition21 PCI−X AX100
366 HPQ Proliant: DL380(G5), DL580(G3)18, Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP2, 19, 20, 25, 29, FC−AL, EMC Y3, 4, 12, See11
DL580(G4) [x86]: Enterprise Edition21, Express, 37 FC−SW CLARiiON Y3, 4, 31
Standard Edition21 PCI−X AX100

11/02/2006 57 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
367 HPQ Proliant DL580(G3)18 Microsoft Windows 2003 PCI, PCI QLogic: QLE220−E−SP2, 19, 48, 49, 53 , FC−AL, EMC Y3, 4, 12, See11
[x86]: Enterprise Edition21, Express, QLE2360−E−SP2, 29, 40, 51, 52 FC−SW CLARiiON Y3, 4, 31
Standard Edition21 PCI−X AX100
368 Fujitsu Siemens Primergy: RX600, TX600 Microsoft Windows 2003 PCI, Emulex LP1050−E2, 9, 22, 76 FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, PCI−X FC−SW CLARiiON
Standard Edition21 AX100
369 HPQ Proliant: DL14518, DL380(G2)18, Microsoft Windows 2003 PCI, Emulex: LP101−E2, 6, 9, 22, 24 , FC−AL, EMC Y3, 4 See10
DL380(G3)18, DL380(G4)18, DL38018, [x86]: Enterprise Edition21, PCI−X LP1050−E2, 6, 8, 9, 22, 24 , LP1150−E2, 8, FC−SW CLARiiON
DL38518, DL580(G2)18, DL580(G3)18, Standard Edition21 9, 19, 22, 23, 24 , LP982−E2, 6, 8, 9, 24, 26 AX100
DL58518, ML350(G3)18, ML370(G3)18,
ML370(G4)18;
IBM: eServer 325 (Model 8835), xSeries x345
(8670), xSeries x445 (8870);
Samsung SS140
370 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, Emulex: LP101−E2, 6, 9, 22, LP1050−E2, FC−AL, EMC Y3, 4 See10
[x86]: Enterprise Edition21, PCI−X 6, 8, 9, 22 , LP982−E2, 6, 8, 9, 26 FC−SW CLARiiON
Standard Edition21 AX100
371 HPQ Proliant: DL14518, DL380(G2)18, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)2, 6, 8, 9, 22, 24 , FC−AL, EMC Y3
DL380(G3)18, DL380(G4)18, DL38018, [x86]: Enterprise Edition21, PCI−X A7388A (LP1050)2, 6, 8, 9, 22, 24 , FC−SW CLARiiON
DL38518, DL580(G2)18, DL58518, Standard Edition21 AD167A/FC2143 (LP1150)8, 9, 19, 22, 24, AX100
ML350(G3)18, ML370(G3)18, ML370(G4)18 129, FCA2214 (QLA2340)2, 14, 25, 29, 37 ,
FCA2408 (LP982)2, 6, 8, 9, 19, 22, 24
372 HPQ Proliant: DL380(G4)18, DL38518, Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)2, 19, FC−AL, EMC Y3, 4 See11
DL58518, ML370(G4)18 [x86]: Enterprise Edition21, PCI−X 20, 25, AE369A/FC1243 (QLA2462)2, 19, FC−SW CLARiiON
Standard Edition21 20, 25 AX100
373 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM 19K1246 (QLA2310)2, 14, 25, 29, 37, FC−AL, EMC Y3
(8670), xSeries x445 (8870) [x86]: Enterprise Edition21, PCI−X 108 FC−SW CLARiiON
Standard Edition21 AX100
374 IBM xSeries: x345 (8670), x445 (8870) Microsoft Windows 2003 PCI, IBM 24P0960 (QLA2340)2, 14, 25, 29, 37, FC−AL, EMC Y3
[x86]: Enterprise Edition21, PCI−X 62 FC−SW CLARiiON
Standard Edition21 AX100
375 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM: 39M5894 (QLA2460)2, 19, 20, 29, 93 , FC−AL, EMC Y3, 4 See11
(8670), xSeries x445 (8870) [x86]: Enterprise Edition21, PCI−X 39M5895 (QLA2462)2, 19, 20, 29, 93 FC−SW CLARiiON
Standard Edition21 AX100
376 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP2, 14, 85 FC−AL, EMC Y3, 4 See11
TX600 [x86]: Enterprise Edition21, PCI−X FC−SW CLARiiON
Standard Edition21 AX100
377 HPQ Proliant: DL14518, DL380(G2)18, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 41, 42, 43, 44, FC−AL, EMC Y3, 4 See11
DL380(G3)18, DL380(G4)18, DL38018, [x86]: Enterprise Edition21, PCI−X 56, QLA210−E−SP19, 41, 54, 56 , FC−SW CLARiiON
DL38518, DL580(G2)18, DL580(G3)18, Standard Edition21 QLA2340−E−SP2, 14, 25, 37 , AX100
DL58518, ML350(G3)18, ML370(G3)18, QLA2460−E−SP2, 19, 20, 25, 29, 37
ML370(G4)18;
IBM: eServer 325 (Model 8835), xSeries x345
(8670), xSeries x445 (8870);
Samsung SS140
378 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP2, 41, 43, 77 , FC−AL, EMC Y3, 4 See11
[x86]: Enterprise Edition21, PCI−X QLA210−E−SP19, 41, 56, 64 , FC−SW CLARiiON
Standard Edition21 QLA2340−E−SP2, 14, 25, 27 AX100
379 Unisys ES7000/460 [32−Bit] Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)9, 76, FC−AL, EMC Y3
[x86]: Enterprise Edition21, PCI−X 119 FC−SW CLARiiON
Standard Edition21 AX100
380 Bull NovaScale: 2021, 2040, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y3
[x86] Enterprise Edition: port for NovaScale Blade Series CLARiiON
R21, SP1; CFSN202−11002, 13, 15, 29, 66 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP1
381 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y3
[x86] Enterprise Edition: port mini for NovaScale Blade 2021 CLARiiON
R21, SP1; CFSN202−21002, 13, 15, 29, 66 , SBEFCM AX100
(SFF) Mezzanine HBA2, 13, 15, 19, 29, 66 ,
Microsoft Windows 2003 SBEFCM4 (SFF) 4Gb Mezzanine HBA2,
[x86] Standard Edition: R21, 19, 28, 99, 100
SP1
382 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA2, FC−SW EMC Y3
[x86] Enterprise Edition: 19, 28, 66, 67 , SBEFCM4 (SFF) 4Gb CLARiiON
R21, SP1; Mezzanine HBA2, 19, 28, 99, 100 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP1
383 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See10
[x86] Enterprise Edition: Express Module AHWFCMOD2, 13, 15, 19, 29, 90, CLARiiON Y3, 4, 12
R21, SP116; 91 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
384 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86] Enterprise Edition: Express Module AHWFCMOD2, 13, 15, 19, 29, 90, CLARiiON Y3, 4, 12,
R21, SP116; 91 AX100 Y3, 4, 31

Microsoft Windows 2003


[x86] Standard Edition: R21,
SP116

11/02/2006 58 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
385 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, See10
[x86] Enterprise Edition: Express AHWFCMOD2, 13, 15, 19, 29, 90, 91 CLARiiON Y3, 4, 12
R21, SP116; AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
386 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, See11
[x86] Enterprise Edition: Express AHWFCMOD2, 13, 15, 19, 29, 90, 91 CLARiiON Y3, 4, 12,
R21, SP116; AX100 Y3, 4, 31
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
387 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See10
[x86] Enterprise Edition: Express, Module AHWFCMOD2, 13, 15, 19, 29, 90, CLARiiON Y3, 4, 12
Intel: SR4850HW4−M/SR6850HW4−M, R21, SP116; PCI−X 91 AX100
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x86] Standard Edition: R21,
G5, T650 SP116
388 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86] Enterprise Edition: Express, Module AHWFCMOD2, 13, 15, 19, 29, 90, CLARiiON Y3, 4, 12,
Intel: SR4850HW4−M/SR6850HW4−M, R21, SP116; PCI−X 91 AX100 Y3, 4, 31
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x86] Standard Edition: R21,
G5, T650 SP116
389 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See10
[x86] Enterprise Edition: Module AHWFCMOD2, 13, 15, 19, 29, 90, CLARiiON
R21, SP116; 91 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
390 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86] Enterprise Edition: Module AHWFCMOD2, 13, 15, 19, 29, 90, CLARiiON Y3, 4, 12
R21, SP116; 91 AX100
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP116
391 Bull NovaScale: 2021, 2040, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y3
[x86]: Enterprise Edition, port for NovaScale Blade Series CLARiiON
Standard Edition CFSN202−11002, 25, 29, 37, 66 AX100
392 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y3
[x86]: Enterprise Edition, port mini for NovaScale Blade 2021 CLARiiON
Standard Edition CFSN202−21002, 25, 29, 37, 66 , SBEFCM AX100
(SFF) Mezzanine HBA2, 19, 25, 29, 37, 66 ,
SBEFCM4 (SFF) 4Gb Mezzanine HBA2,
19, 25, 99, 100

393 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA2, FC−SW EMC Y3
[x86]: Enterprise Edition, 19, 25, 37, 66 , SBEFCM4 (SFF) 4Gb CLARiiON
Standard Edition Mezzanine HBA2, 19, 25, 99, 100 AX100
394 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12
Standard Edition21 91 AX100
395 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12,
Standard Edition21 91 AX100 Y3, 4, 31
396 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express AHWFCMOD2, 19, 25, 29, 37, 90, 91 CLARiiON Y3, 4, 12
Standard Edition21 AX100
397 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express AHWFCMOD2, 19, 25, 29, 37, 90, 91 CLARiiON Y3, 4, 12,
Standard Edition21 AX100 Y3, 4, 31

398 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See10
[x86]: Enterprise Edition21, Express, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition21 PCI−X 91 AX100
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
399 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Express, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12,
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition21 PCI−X 91 AX100 Y3, 4, 31
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
400 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See10
[x86]: Enterprise Edition21, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON
Standard Edition21 91 AX100
401 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See11
[x86]: Enterprise Edition21, Module AHWFCMOD2, 19, 25, 29, 37, 90, CLARiiON Y3, 4, 12
Standard Edition21 91 AX100

11/02/2006 59 CLARiiON AX100


CLARiiON AX100

1. VDS (Virtual Disk Service) is currently supported for Windows 2003 R2 operating systems. EMC Solutions Enabler 6.2 (minimum version) is required to support VDS for Windows 2003
R2.
2. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
3. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
4. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
5. Driver Version 1.11a3
6. Firmware Version 1.91a5
7. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
8. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver
to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
9. BIOS 1.70a3
10. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
11. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
12. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
13. Driver Version 9.1.2.16 STORPort Miniport Driver
14. BIOS 1.47
15. Driver Version 9.1.2.15 STORPort Miniport Driver
16. Supports LUNs greater than 2TB in size. Minimum Service Pack 1 (SP1) required.
17. Driver Version 1.20a3 STORPort Miniport Driver
18. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
19. SNIA HBA API Supported.
20. BIOS 1.08
21. Maximum supported LUN size is 2TB for Windows 2003 without Service Pack 1 (SP1.)
22. Driver Version 1.11a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
23. Firmware Version 2.10a10
24. Driver Version 1.20a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
25. Driver Version 9.1.2.16 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
26. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
27. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
28. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
29. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
30. Driver Version 1.11a3 STORPort Miniport Driver
31. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar
SCSI.)
32. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
33. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
34. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003.
35. Firmware Version 2.50a6
36. BIOS 1.11
37. Driver Version 9.1.2.15 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
38. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
39. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
40. BIOS 1.05
41. BIOS 1.23
42. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
43. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
44. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
45. Supports Stratus OS 3.1.x.
46. Firmware Version 2.50a8
47. Driver Version 1.20a3
48. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
49. BIOS 1.02
50. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
51. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
52. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
53. Driver Version 9.1.2.19 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
54. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. SCSI Miniport (SCSIPort) Driver
55. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
56. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
57. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
58. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
59. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
60. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI FC Port driver As of 2.40a2 Microsoft will no longer allow the
Emulex Port Driver to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO
solution and block submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
61. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.

11/02/2006 60 CLARiiON AX100


CLARiiON AX100

62. This HBA is equivalent to the QLogic QLA2340.


63. Accepts PCI−X 1.0 and 2.0 HBAs.
64. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. This driver requires Microsoft SCSIPort hotfix Q883114. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];883114 SCSI Miniport (SCSIPort) Driver
65. Requires Stratus OS 3.1
66. BIOS 1.43
67. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
68. QLogic SANSurfer/SANBlade Manager is not supported. Use QLogic SANCLI utility.
69. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. SCSI Miniport (SCSIPort) Driver
70. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
71. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
72. BIOS 1.45
73. Firmware Version 1.91a2
74. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. STORPort Miniport Driver
75. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
76. Firmware Version 1.91a1
77. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
78. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
79. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
80. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
81. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
82. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
83. Supports Stratus OS 4.1 FTSSS Release
84. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
85. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
86. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
87. BIOS 1.48
88. Driver Version 9.1.2.14
89. BIOS 1.16
90. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
91. BIOS 1.06
92. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com Requires Microsoft STORPort hotfix
Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently requires Service Pack 1 (SP1) to be installed before the hotfix
can be installed. STORPort Miniport Driver
93. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com STORPort Miniport Driver Requires
Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
94. 3.2Ghz and 3.6Ghz versions of this server are supported.
95. Firmware Version 2.50a4
96. Firmware Version 1.90a4
97. BX600 uses an embedded fibre channel controller. Contact Fujitsu Siemens to acquire proper BIOS for embedded fibre channel controller.
98. Please read Stratus CAC Alert 2300 prior to the installation of QLA2460−E−SP HBAs.
99. BIOS 1.12
100. Driver Version 9.1.2.11
101. Driver Version 9.1.2.10 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
102. Driver Version 9.1.2.10 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
103. QLogic SanBlade Manager is not supported.
104. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
105. Supports Stratus OS 2.0.X through 2.1.X.
106. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
107. Supports Stratus OS 1.3.X through 2.1.X.
108. This HBA is equivalent to the QLogic QLA2310.
109. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
110. Driver Version 1.10x1
111. RPQ or Unisys Custom Engineering Request (CER) required.
112. Driver Version 1.10a4 STORPort Miniport Driver
113. Driver Version 1.02a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
114. Driver Version 1.10a4 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
115. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
116. Driver Version 1.02a3 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
117. Driver Version 1.11a1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
118. Driver Version 1.11u1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
119. Driver Version 1.11u1 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
120. Driver Version 1.11a1 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
121. Driver Version 1.02a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
122. Driver Version 1.10x1 Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
123. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
124. Driver Version 1.10x1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
125. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm

11/02/2006 61 CLARiiON AX100


CLARiiON AX100

126. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
127. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
128. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
129. Firmware Version 2.10a9
130. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
131. Driver Version 9.1.2.15
132. Driver Version 1.11u1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm

MiracleLinux MLSE [32−Bit]

MiracleLinux MLSE [32−Bit]


Host Bus Storage External
No. Host System Operating System Host Bus Adapter Topology Array Boot
1 HPQ Proliant: DL3206, DL360(G2)6, DL3606, DL380(G2)6, DL380(G3)6, DL3806, MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
DL580(G2)6, DL5806, ML350(G2)6, ML350(G3)6, ML3506, ML370(G2)6, ML3706, [32−Bit] 4.0 SP1 QLE220−E−SP1, FC−SW CLARiiON
ML530(G2)6, ML530(G3)6, ML5306, ML5706, ML7506 v2.6.9−34.21AX4, 5 2, 3, 7 AX100
2 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; MiracleLinux MLSE PCI Emulex FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express LPe111−E2, 8, FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.21AX4, 5 9, 10 AX100
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)6, DL380(G4)6, DL580(G3)6, ML350(G4)6, ML370(G4)6;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
3 Dell PowerEdge 1950 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 2, 3 AX100
4 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 2, 3, 7 AX100
5 Dell PowerEdge: 2900, 2950, 6950; MiracleLinux MLSE PCI Emulex FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, LPe111−E2, 8, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX4, 5 PCI−X 9, 10 AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, 6950; MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP1, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX4, 5 PCI−X 2, 3 AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
7 HPQ Proliant ML350(G4)6 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 PCI−X 2, 3, 7 AX100
8 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 PCI−X11 2, 3, 7 AX100
9 Digital Henge SH4500R4; MiracleLinux MLSE PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; [32−Bit] 4.0 SP1 QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 2, 3, 7 AX100
HPQ Proliant: BL40p, DL360(G3)6, DL360(G4)6, DL5606, DL7406, DL760 (G2)6,
DL7606, ML570(G2)6;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
10 Dell PowerEdge: 1800, 2800 MiracleLinux MLSE PCI, PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 PCI−X 2, 3 AX100
11 HPQ Proliant: DL1456, DL380(G2)6, DL380(G3)6, DL380(G4)6, DL3806, DL3856, MiracleLinux MLSE PCI, QLogic FC−AL, EMC Y
DL580(G2)6, DL580(G3)6, DL5856, ML370(G3)6, ML370(G4)6; [32−Bit] 4.0 SP1 PCI−X QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX4, 5 2, 3, 7 AX100
Samsung SS140
1. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
2. SNIA HBA API Supported.
3. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
4. Native multipathing is not supported on boot−from−SAN configurations.
5. Based on Asianux 2.0.
6. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
7. Driver/BIOS are available at http://www.qlogic.com
8. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
9. Driver Version 8.0.16.18 Driver is integrated into the kernel.
10. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

MiracleLinux MLSE [AMD64]

11/02/2006 62 CLARiiON AX100


CLARiiON AX100

MiracleLinux MLSE [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge 6950 MiracleLinux MLSE [AMD64] 4.0 SP1 PCI Express, Emulex LPe111−E5, 10, 11, 13 ; FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX1, 2 PCI−X QLogic QLE220−E−SP5, 6, 7 FC−SW AX100
2 Sun: x4100, x4200 MiracleLinux MLSE [AMD64] 4.0 SP1 PCI−X Emulex: LP1050−E5, 10, 11, 12 , FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX1, 2 LP982−E5, 10, 11; FC−SW AX100
QLogic QLA2340−E−SP3, 4, 5
3 HPQ Proliant: DL1459, MiracleLinux MLSE [AMD64] 4.0 SP1 PCI, PCI−X QLogic QLE220−E−SP5, 6, 7, 8 FC−AL, EMC CLARiiON Y
DL3859, DL5859 v2.6.9−34.21AX1, 2 FC−SW AX100
1. Native multipathing is not supported on boot−from−SAN configurations.
2. Based on Asianux 2.0.
3. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
5. SNIA HBA API Supported.
6. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
7. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
8. Driver/BIOS are available at http://www.qlogic.com
9. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Driver Version 8.0.16.18 Driver is integrated into the kernel.
11. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
12. Firmware Version 1.91a5
13. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

MiracleLinux MLSE [EM64T]

MiracleLinux MLSE [EM64T]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, MiracleLinux MLSE [EM64T] 4.0 PCI Express Emulex LPe111−E4, FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX1, 2 6, 7, 8 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
2 Dell PowerEdge 1950 MiracleLinux MLSE [EM64T] 4.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 4, 5 FC−SW CLARiiON
AX100
3 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE [EM64T] 4.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 4, 5, FC−SW CLARiiON
10 AX100
4 Dell PowerEdge: 2900, 2950; MiracleLinux MLSE [EM64T] 4.0 PCI Express, Emulex LPe111−E4, FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 PCI−X 6, 7, 8 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
5 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, MiracleLinux MLSE [EM64T] 4.0 PCI Express, QLogic FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX1, 2 PCI−X QLE220−E−SP3, 4, 5 FC−SW CLARiiON
AX100
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)9 MiracleLinux MLSE [EM64T] 4.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 PCI−X QLE220−E−SP3, 4, 5, FC−SW CLARiiON
10 AX100
7 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE [EM64T] 4.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 PCI−X11 QLE220−E−SP3, 4, 5, FC−SW CLARiiON
10 AX100
8 Digital Henge SH4500R4; MiracleLinux MLSE [EM64T] 4.0 PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 4, 5, FC−SW CLARiiON
TX300 S2; 10 AX100
HPQ Proliant DL360(G4)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003
9 Dell PowerEdge: 1800, 2800 MiracleLinux MLSE [EM64T] 4.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 Express, PCI−X QLE220−E−SP3, 4, 5 FC−SW CLARiiON
AX100
10 HPQ Proliant DL580(G3)9 MiracleLinux MLSE [EM64T] 4.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 Express, PCI−X QLE220−E−SP3, 4, 5, FC−SW CLARiiON
10 AX100
11 HPQ Proliant: DL380(G4)9, ML370(G4)9 MiracleLinux MLSE [EM64T] 4.0 PCI, PCI−X QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX1, 2 QLE220−E−SP3, 4, 5, FC−SW CLARiiON
10 AX100
1. Native multipathing is not supported on boot−from−SAN configurations.
2. Based on Asianux 2.0.
3. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
4. SNIA HBA API Supported.
5. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
6. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. Driver Version 8.0.16.18 Driver is integrated into the kernel.
9. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Driver/BIOS are available at http://www.qlogic.com

11/02/2006 63 CLARiiON AX100


CLARiiON AX100

11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Novell Netware

Novell Netware
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5 SP31, 22 Express QLE2360−E−SP19, 21, FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL380(G4)29, DL580(G3)29, ML370(G4)29; 26, 27 9, 10, 11, 12, 13, 15,
16, 23
IBM xSeries x336 (8837)31
2 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5 SP31, 22 Express QLE2460−E−SP19, 20, 21 FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL580(G3)29, ML370(G4)29 9, 10, 11, 12, 13, 15,
16, 23

3 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y
6.5 SP31, 22 QLA2340−E−SP18, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX200 S2, RX300, RX300 S2, 9, 10, 11, 12, 13, 15,
TX150, TX200, TX200 S2, TX300, TX300 S2; 16, 23

HPQ Proliant: DL360(G3)29, DL56029, DL74029, DL760 (G2)29, DL76029,


ML570(G2)29;
IBM xSeries: x235, x255, x336 (8837)31, x346 (8840)31, x3850/x366
(8863)30;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
4 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y
6.5 SP41, 22 QLA2340−E−SP18, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX300, TX150, TX200, TX300; 9, 10, 11, 12, 13, 15,
16, 23
HPQ Proliant: DL360(G3)29, DL56029, DL74029, DL760 (G2)29, DL76029,
ML570(G2)29;
IBM xSeries: x235, x255, x336 (8837)31, x346 (8840)31, x3850/x366
(8863)30;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
5 Fujitsu Siemens Primergy RX300 S2 Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y
6.5 SP422 QLA2340−E−SP18, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
9, 10, 11, 12, 13, 15,
16, 23

6 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255028, 4300, 4350, 4400, Novell Netware PCI QLogic: FC−AL, EMC CLARiiON Y4, 5, 6,
6100, 6300, 6350, 6400, 6450, 8450; 6.5: SP1.11, QLA200−E−SP2, 3, FC−SW AX100 7, 8, 9, 10,
SP21 QLA2340−E−SP3, 18 11, 12, 13,
14, 15, 16,
HPQ Proliant: DL32029, DL360(G2)29, DL36029, DL58029, ML350(G2)29, 17
ML350(G3)29, ML35029, ML370(G2)29, ML37029, ML530(G2)29,
ML530(G3)29, ML53029, ML57029, ML75029;
IBM: Netfinity 4500R, xSeries x225, xSeries x230, xSeries x232, xSeries
x240, xSeries x250, xSeries x330, xSeries x335, xSeries x340 (4500R),
xSeries x342, xSeries x350 (6000R), xSeries x370
7 Dell PowerEdge: 1800, 2800 Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y4, 5, 6,
6.5: SP1.11, Express QLE2360−E−SP3, 26 FC−SW AX100 7, 8, 9, 10,
SP21 11, 12, 13,
14, 15, 16,
17

8 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON Y4, 5, 6,
6.5: SP1.11, 3 FC−SW AX100 7, 8, 9, 10,
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029, SP21 11, 12, 13,
14, 15, 16,
DL760 (G2)29, DL76029, ML570(G2)29; 17

IBM xSeries: x235, x255, x360, x365, x3850/x366 (8863)30, x440;


LangChao: NC2000, NF420;
Samsung SS210
9 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y4, 5, 6,
6.5: SP1.11, QLA2340−E−SP3, 18 FC−SW AX100 7, 8, 9, 10,
Fujitsu Siemens Primergy: RX200, RX300, TX150, TX200, TX300; SP21 11, 12, 13,
14, 15, 16,
17
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029,
DL760 (G2)29, DL76029, ML570(G2)29;
IBM xSeries: x235, x255, x360, x365, x3850/x366 (8863)30, x440;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
10 HPQ Proliant BL20p (G3) Novell Netware PCI−X25 HPQ Dual−port Fibre FC−AL, EMC CLARiiON Y4, 5, 6,
6.5: SP1.11, Channel Adapter for HP FC−SW AX100 7, 8, 9, 10,
SP21 Proliant BL20p (G3) 11, 12, 13,
14, 15, 16,
361426−B213, 24 17

11 Dell PowerEdge 1850; Novell Netware PCI, QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON Y4, 5, 6,
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029, 6.5: SP1.11, PCI−X 3 FC−SW AX100 7, 8, 9, 10,
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29; SP21 11, 12, 13,
14, 15, 16,
17
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140

11/02/2006 64 CLARiiON AX100


CLARiiON AX100

Novell Netware
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot
12 Dell PowerEdge 1850; Novell Netware PCI, QLogic FC−AL, EMC CLARiiON Y4, 5, 6,
Fujitsu Siemens Primergy: RX600, TX600; 6.5: SP1.11, PCI−X QLA2340−E−SP3, 18 FC−SW AX100 7, 8, 9, 10,
SP21 11, 12, 13,
14, 15, 16,
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029, 17
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
13 HPQ Proliant BL20p (G3) Novell Netware PCI−X25 HPQ Dual−port Fibre FC−AL, EMC CLARiiON N
6.5: SP1.11, Channel Adapter for HP FC−SW AX100
SP21; Proliant BL20p (G3)
361426−B213, 24
Novell Netware
6.51
14 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255028, 4300, 4350, 4400, Novell Netware PCI QLogic: FC−AL, EMC CLARiiON Y
6100, 6300, 6350, 6400, 6450, 8450; 6.5: SP31, 22, QLA200−E−SP2, 19, 21, FC−SW AX1004, 5, 6, 7, 8,
SP41, 22, QLA2340−E−SP18, 19, 21 9, 10, 11, 12, 13, 15,
HPQ Netserver LC: 2000 U3, 2000r; SP4a22, SP522 16, 23

HPQ Netserver LH: (LH Pro), 3, 300033, 4, 6000/LH 6000r, II, PRO, lll;
HPQ Netserver: LP 2000r, LT 6000R, LX PRO, LXR 8000, LXR 8500, LXR
PRO, LXR PRO8;
HPQ Proliant: 160029, 185029, 250029, 300029, 500029, 550029, 600029,
6400R, 650029, 700029, 800029, 850, 850029, DL32029, DL360(G2)29,
DL36029, DL58029, ML350(G2)29, ML35029, ML370(G2)29, ML37029,
ML530(G2)29, ML530(G3)29, ML53029, ML57029, ML75029;
IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20, 5600, 6000R,
7000, 7000 M1034, 7100, 7600, 8500, 8500R;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335, x340 (4500R), x350
(6000R)
15 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON Y
6.5: SP31, 22, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX300, TX150, TX200, TX300; SP41, 22, 9, 10, 11, 12, 13, 15,
SP4a22, SP522 16, 23
HPQ Proliant: DL360(G3)29, DL56029, DL74029, DL760 (G2)29, DL76029,
ML570(G2)29;
IBM xSeries: x235, x255, x336 (8837)31, x346 (8840)31, x3850/x366
(8863)30;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
16 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI, QLogic: FC−AL, EMC CLARiiON Y
6.5: SP31, 22, PCI−X QLA200−E−SP2, 19, 21, FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: RX600, TX600; SP41, 22, QLA2340−E−SP18, 19, 21 9, 10, 11, 12, 13, 15,
SP4a22, SP522 16, 23
HPQ Proliant: DL360(G4)29, DL380(G2)29, DL380(G3)29, DL380(G4)29,
DL38029, DL580(G2)29, DL580(G3)29, ML350(G3)29, ML370(G3)29,
ML370(G4)29;
IBM xSeries: x342, x345 (8670), x360, x365, x370, x440, x445 (8870);
Samsung SS140
17 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5: SP41, 22, Express QLE2360−E−SP19, 21, FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL380(G4)29, DL580(G3)29, ML370(G4)29; SP4a22, SP522 26, 27 9, 10, 11, 12, 13, 15,
16, 23
IBM xSeries x336 (8837)31
18 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic: FC−AL, EMC CLARiiON Y
6.5: SP41, 22, Express, QLA200−E−SP2, 19, 21, FC−SW AX1004, 5, 6, 7, 8,
SP4a22, SP522 PCI−X QLA2340−E−SP18, 19, 9, 10, 11, 12, 13, 15,
21, QLE2360−E−SP19, 16, 23
21, 26, 27

19 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5: SP422, Express QLE2460−E−SP19, 20, 21 FC−SW AX1004, 5, 6, 7, 8,
HPQ Proliant: DL360(G4)29, DL580(G3)29, ML370(G4)29 SP4a22, SP522 9, 10, 11, 12, 13, 15,
16, 23

20 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic FC−AL, EMC CLARiiON Y
6.5: SP422, Express, QLE2460−E−SP19, 20, 21 FC−SW AX1004, 5, 6, 7, 8,
SP4a22, SP522 PCI−X 9, 10, 11, 12, 13, 15,
16, 23

21 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON Y
6.5: SP4a22, QLA2340−E−SP18, 19, 21 FC−SW AX1004, 5, 6, 7, 8,
Fujitsu Siemens Primergy: F25032, RX200, RX300, RX300 S2, TX150, SP522 9, 10, 11, 12, 13, 15,
TX200, TX300; 16, 23

HPQ Proliant: DL360(G3)29, DL56029, DL74029, DL760 (G2)29, DL76029,


ML570(G2)29;
IBM xSeries: x235, x255, x336 (8837)31, x346 (8840)31, x3850/x366
(8863)30;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
22 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255028, 4300, 4350, 4400, Novell Netware PCI QLogic: FC−AL, EMC CLARiiON N
6100, 6300, 6350, 6400, 6450, 8450; 6.51 QLA200−E−SP2, 3, FC−SW AX100
QLA2340−E−SP3, 18
HPQ Proliant: DL32029, DL360(G2)29, DL36029, DL58029, ML350(G2)29,
ML350(G3)29, ML35029, ML370(G2)29, ML37029, ML530(G2)29,
ML530(G3)29, ML53029, ML57029, ML75029;
IBM: Netfinity 4500R, xSeries x225, xSeries x230, xSeries x232, xSeries
x240, xSeries x250, xSeries x330, xSeries x335, xSeries x340 (4500R),
xSeries x342, xSeries x350 (6000R), xSeries x370

11/02/2006 65 CLARiiON AX100


CLARiiON AX100

Novell Netware
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot
23 Dell PowerEdge: 1800, 2800 Novell Netware PCI QLogic FC−AL, EMC CLARiiON N
6.51 Express QLE2360−E−SP3, 26 FC−SW AX100
24 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON N
6.51 3 FC−SW AX100
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029,
DL760 (G2)29, DL76029, ML570(G2)29;
IBM xSeries: x235, x255, x360, x365, x3850/x366 (8863)30, x440;
LangChao: NC2000, NF420;
Samsung SS210
25 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC CLARiiON N
6.51 QLA2340−E−SP3, 18 FC−SW AX100
Fujitsu Siemens Primergy: RX200, RX300, TX150, TX200, TX300;
HPQ Proliant: BL40p, DL360(G3)29, DL360(G4)29, DL56029, DL74029,
DL760 (G2)29, DL76029, ML570(G2)29;
IBM xSeries: x235, x255, x360, x365, x3850/x366 (8863)30, x440;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
26 Dell PowerEdge 1850; Novell Netware PCI, QLogic QLA200−E−SP2, FC−AL, EMC CLARiiON N
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029, 6.51 PCI−X 3 FC−SW AX100
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
27 Dell PowerEdge 1850; Novell Netware PCI, QLogic FC−AL, EMC CLARiiON N
Fujitsu Siemens Primergy: RX600, TX600; 6.51 PCI−X QLA2340−E−SP3, 18 FC−SW AX100
HPQ Proliant: DL380(G2)29, DL380(G3)29, DL380(G4)29, DL38029,
DL580(G2)29, DL580(G3)29, ML370(G3)29, ML370(G4)29;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
1. PowerPath is not supported in conjunction with host−based mirroring.
2. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 6.80g
4. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
5. No MirrorView or SnapView used on boot LUNs.
6. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
7. Novell Storage Services supported.
8. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
9. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After Abend".
When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
10. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
11. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any found in
previous boot documentation.
12. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
13. Remote boot not supported with PERC controllers enabled in system BIOS.
14. Refer to the Customer Service website or your EMC Service Personnel for the latest documentation.
15. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
16. Supports eight (8) hosts per array.
17. Edit config.sys with the following: Files=100 Buffers=99
18. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Driver Version 6.90m
20. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. SNIA HBA API Supported.
22. Novell OES is supported on this kernel.
23. Edit config.sys with the following: Files=100, Buffers=99
24. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
26. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
28. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
29. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
30. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
31. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
32. Must use standard PCI 32bit/33MHz slot for SCSI
33. HP Netserver LH3000 U3 is supported in the same configurations as the standard LH 3000.
34. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).

Oracle Enterprise Linux [32−Bit]

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255041, Oracle Enterprise PCI Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; Linux [32−Bit] 4 U4 QLogic: QLA200−E−SP4, 9, 24, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLA210−E−SP4, 9, 24 AX100
HPQ Proliant: DL32011, DL360(G2)11, DL36011,
DL380(G2)11, DL380(G3)11, DL38011, DL580(G2)11,
DL58011, ML350(G2)11, ML350(G3)11, ML35011,
ML370(G2)11, ML37011, ML530(G2)11, ML530(G3)11,
ML53011, ML57011, ML75011

11/02/2006 66 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
2 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255041, Oracle Enterprise PCI Emulex: LP1050−E1, 2, 9, 10, LP982−E1, 2, 9; FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP3, 4, 9 AX100
3 HPQ Proliant: DL32011, DL360(G2)11, DL36011, DL58011, Oracle Enterprise PCI Emulex: LP1050−E1, 2, 10, LP982−E1, 2 FC−AL, EMC Y
ML350(G2)11, ML350(G3)11, ML35011, ML370(G2)11, Linux [32−Bit] 4 U4 FC−SW CLARiiON
ML37011, ML530(G2)11, ML530(G3)11, ML53011, ML57011, v2.6.9−42.0.0.0.1.EL AX100
ML75011
4 HPQ Proliant: DL32011, DL360(G2)11, DL36011, Oracle Enterprise PCI HPQ AD167A/FC2143 (LP1150)1, 2, 9, 12; FC−AL, EMC Y
DL380(G2)11, DL380(G3)11, DL38011, DL580(G2)11, Linux [32−Bit] 4 U4 QLogic: QLA2340−E−SP3, 4, FC−SW CLARiiON
DL58011, ML350(G2)11, ML350(G3)11, ML35011, v2.6.9−42.0.0.0.1.EL QLE220−E−SP9, 14, 15 AX100
ML370(G2)11, ML37011, ML530(G2)11, ML530(G3)11,
ML53011, ML57011, ML75011
5 NEC Express 5800: 120Rd−1, 120Rf−2, 140Hd, 140Rc−4, Oracle Enterprise PCI NEC N8190−120 (LP1050)1, 2, 19, 27 FC−AL, EMC Y
180Rd−4 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
6 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850; Oracle Enterprise PCI Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express QLogic: QLA200−E−SP4, 9, 24, FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400 v2.6.9−42.0.0.0.1.EL QLA210−E−SP4, 9, 24 AX100
7 Dell PowerEdge: 1800, 2800, 2850 Oracle Enterprise PCI Emulex LP1050−E1, 2, 9, 10; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express QLogic QLA2340−E−SP3, 4, 9 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
8 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Oracle Enterprise PCI Emulex LP1050Ex−E1, 2, 9, 19 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)43;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
9 Dell PowerEdge: 1800, 2800, 2850; Oracle Enterprise PCI Emulex LP982−E1, 2, 9 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Samsung ZSS230 v2.6.9−42.0.0.0.1.EL AX100
10 Samsung ZSS230 Oracle Enterprise PCI Emulex: LP101−E1, 2, 19, LP1050−E1, 2, 10, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express LP982−E1, 2; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
QLogic QLA2340−E−SP3, 4
11 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Oracle Enterprise PCI Emulex: LPe111−E1, 2, 9, 23, LPe1150−E1, 2, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express 9, 17 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)11, DL380(G4)11, DL580(G3)11,
ML350(G4)11, ML370(G4)11;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
12 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y44, 45
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express HP c−Class Bladesystem (403621−B21)1, 6, FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL 23 AX100
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
13 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y8
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express HP c−Class Bladesystem (403621−B21)1, 6, FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL 7 AX100
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
14 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ QLogic QMH2462 4Gb FC HBA for HP FC−AL, EMC N
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express c−Class Bladesystem (403619−B21)4, 5 FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL AX100
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
15 HPQ Proliant: DL360(G4)11, DL380(G4)11, DL580(G3)11, Oracle Enterprise PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 9, FC−AL, EMC Y
ML350(G4)11, ML370(G4)11 Linux [32−Bit] 4 U4 Express 22, AD167A/FC2143 (LP1150)1, 2, 9, 12 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
16 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express for HP c−Class Bladesystem FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL (403621−B21)1, 6, 7, QLogic QMH2462 4Gb AX100
FC HBA for HP c−Class Bladesystem
HPQ Proliant BL465c: (403433−B21), (403434−B21), (403619−B21)4, 5
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)

11/02/2006 67 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
17 IBM xSeries x3455 (7984) Oracle Enterprise PCI IBM: 42C2069 (LPe11000)1, 2, 9, 22, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express 42C2071 (LPe11002)1, 2, 9, 17; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
QLogic: QLE2360−E−SP4, 9, 20,
QLE2362−E−SP4, 9, 20, QLE2462−E−SP4, 9,
18

18 Dell PowerEdge 1950; Oracle Enterprise PCI QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
19 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise PCI QLogic QLE2360−E−SP4, 20, 21 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; v2.6.9−42.0.0.0.1.EL AX100
Samsung ZSS230
20 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Oracle Enterprise PCI QLogic QLE2360−E−SP4, 9, 20, 21 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)43;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
21 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Oracle Enterprise PCI QLogic QLE2460−E−SP4, 9, 18 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
22 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, QLogic: QLA200−E−SP4, 9, 24, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X QLA210−E−SP4, 9, 24 AX100
HPQ Proliant ML350(G4)11;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
23 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP1050−E1, 2, 9, 10; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, QLogic QLA2340−E−SP3, 4, 9 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX100
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
24 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP982−E1, 2, 9 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
25 HPQ Proliant ML350(G4)11 Oracle Enterprise PCI Emulex: LP1050−E1, 2, 10, LP982−E1, 2; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, AX100
AD167A/FC2143 (LP1150)1, 2, 9, 12,
AE369A/FC1243 (QLA2462)4, 9, 34;
QLogic QLA2340−E−SP3, 4
26 Dell PowerEdge: 2900, 2950, 6950; Oracle Enterprise PCI Emulex: LP1050Ex−E1, 2, 9, 19, LPe111−E1, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 2, 9, 23, LPe1150−E1, 2, 9, 17; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX100
QLogic: QLE2360−E−SP4, 9, 20, 21 ,
Intel: SR1500/S5000PAL, SR2500/S5000PAL QLE2460−E−SP4, 9, 18
27 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) Oracle Enterprise PCI IBM: 24P0960 (QLA2340)3, 4, 9, 28, 24P8053 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, (QLA2342)3, 4, 9; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
QLogic: QLA2460−E−SP4, 9, 18,
QLE2360−E−SP4, 9, 30, QLE2460−E−SP4, 9,
29

28 NEC Express 5800: 120Li, 120Rg−1, 120Ri−2, 140Hf, Oracle Enterprise PCI NEC: N8190−120 (LP1050)1, 10, 26, 27 , FC−AL, EMC Y
140Re−4 Linux [32−Bit] 4 U4 Express, N8190−127 (LPe1150)1, 17, 26, 27 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
29 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, Oracle Enterprise PCI QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
6950; Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550, AS2500;
HPQ Proliant ML350(G4)11;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
30 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise PCI Emulex: LP101−E1, 2, 9, 19, LP1050−E1, 2, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 10, LP982−E1, 2; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X42 AX100
QLogic: QLA200−E−SP4, 9, 24,
QLA210−E−SP4, 9, 24, QLA2340−E−SP3, 4,
QLE220−E−SP9, 14, 15
31 Dell PowerEdge 1855 Oracle Enterprise PCI−X Dell: 2342M3, 4, LPe1105−M1, 2, 9, 17, FC−AL, EMC Y
Linux [32−Bit] 4 U4 QME24624, 9, 40 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100

11/02/2006 68 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
32 Dell PowerEdge: 2600, 2650, 6600, 6650; Oracle Enterprise PCI−X Emulex LP101−E1, 2, 19 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
LangChao: NC3000, NC3500, NF500, NF520
33 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950, 2600, Oracle Enterprise PCI−X Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
2650, 6600, 6650; Linux [32−Bit] 4 U4 QLogic QLA200−E−SP4, 9, 24 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)11, DL360(G4)11, DL56011,
DL74011, DL760 (G2)11, DL76011, ML570(G2)11;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
34 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950, 2600, Oracle Enterprise PCI−X Emulex LP1050−E1, 2, 9, 10 FC−AL, EMC Y
2650, 6600, 6650; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)43, x346 (8840)43;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
35 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600, 2650, Oracle Enterprise PCI−X Emulex LP982−E1, 2, 9 FC−AL, EMC Y
6600, 6650; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)43, x346 (8840)43;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
36 Dell PowerEdge: 2600, 2650, 6600, 6650; Oracle Enterprise PCI−X Emulex: LP1050−E1, 2, 10, LP982−E1, 2 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
HPQ Proliant: BL40p, DL360(G3)11, DL360(G4)11, DL56011,
DL760 (G2)11, DL76011, ML570(G2)11;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: SS370, SS3840
37 HPQ Proliant: BL40p, DL360(G3)11, DL360(G4)11, DL56011, Oracle Enterprise PCI−X HPQ AD167A/FC2143 (LP1150)1, 2, 9, 12 FC−AL, EMC Y
DL74011, DL760 (G2)11, DL76011, ML570(G2)11 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
38 HPQ Proliant BL45p Oracle Enterprise PCI−X HPQ Emulex−based BL25/30/35/45p Fibre FC−AL, EMC Y
Linux [32−Bit] 4 U4 Channel Mezzanine HBA − 394588−B211, 2, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL 38, 39 AX100
39 HPQ Proliant DL360(G4)11 Oracle Enterprise PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, FC−AL, EMC Y
Linux [32−Bit] 4 U4 AE369A/FC1243 (QLA2462)4, 9, 34 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
40 NEC Express 5800: 120Lh, 120Re−1, 120Rf−1, 120Rg−2, Oracle Enterprise PCI−X NEC N8190−120 (LP1050)1, 2, 19, 27 FC−AL, EMC Y
120Rh−2, 140He, 140Rd−4 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
41 NEC Express 5800: 140He, 140Rd−4 Oracle Enterprise PCI−X NEC N8190−127 (LPe1150)1, 2, 22, 27 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
42 Dell PowerEdge: 2600, 2650, 6600, 6650 Oracle Enterprise PCI−X QLogic QLA200−E−SP4, 24 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
43 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600, 2650, Oracle Enterprise PCI−X QLogic QLA210−E−SP4, 9, 24 FC−AL, EMC Y
6600, 6650; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)11, DL360(G4)11, DL56011,
DL74011, DL760 (G2)11, DL76011, ML570(G2)11;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
44 Dell PowerEdge: 2600, 2650, 6600, 6650; Oracle Enterprise PCI−X QLogic QLA2340−E−SP3, 4 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)11, DL360(G4)11, DL56011,
DL74011, DL760 (G2)11, DL76011, ML570(G2)11;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840

11/02/2006 69 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
45 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950; Oracle Enterprise PCI−X QLogic QLA2340−E−SP3, 4, 9 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX100
IBM xSeries: x255, x336 (8837)43, x346 (8840)43;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
46 Sun: x4100, x4200 Oracle Enterprise PCI−X QLogic QLA2460−E−SP4, 9, 18 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
47 Digital Henge SH4500R4; Oracle Enterprise PCI−X QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
HPQ Proliant: BL40p, DL360(G3)11, DL360(G4)11, DL56011,
DL74011, DL760 (G2)11, DL76011, ML570(G2)11;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
48 HPQ Proliant BL20p: (G3), (G4) Oracle Enterprise PCI−X37 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y
Linux [32−Bit] 4 U4 Channel Mezzanine HBA − 394757−B211, 2, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL 38, 39 AX100
49 HPQ Proliant: BL25p, BL30p, BL35p Oracle Enterprise PCI−X37 HPQ Emulex−based BL25/30/35/45p Fibre FC−AL, EMC Y
Linux [32−Bit] 4 U4 Channel Mezzanine HBA − 394588−B211, 2, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL 38, 39 AX100
50 Dell PowerEdge 1955 Oracle Enterprise PCI, PCI Dell: LPe1105−M1, 2, 9, 17, QME24624, 9, 40 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
51 HPQ Proliant: DL380(G5), DL580(G4) Oracle Enterprise PCI, PCI Emulex: LP101−E1, 2, 9, 19, LP1050−E1, 2, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 10, LP982−E1, 2, LPe111−E1, 2, 9, 23, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X LPe1150−E1, 2, 9, 17; AX100
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 9,
22, AD167A/FC2143 (LP1150)1, 2, 9, 12 ,
AE311A/FC1142SR (QLE2460)4, 9, 18,
AE312A/FC1242SR (QLE2462)4, 9, 18;
QLogic: QLA200−E−SP4, 9, 24,
QLA210−E−SP4, 9, 24, QLA2340−E−SP3, 4,
QLE2460−E−SP4, 9, 18, QLE2462−E−SP4, 9,
18

52 HPQ Proliant DL380(G5) Oracle Enterprise PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, AE369A/FC1243 (QLA2462)4, 9, 34 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
53 Dell PowerEdge: 1800, 2800; Oracle Enterprise PCI, PCI QLogic QLE220−E−SP9, 14, 15 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) v2.6.9−42.0.0.0.1.EL PCI−X AX100
54 HPQ Proliant: DL14511, DL380(G2)11, DL380(G3)11, Oracle Enterprise PCI, Emulex LP101−E1, 2, 9, 19; FC−AL, EMC Y
DL380(G4)11, DL38011, DL38511, DL580(G2)11, Linux [32−Bit] 4 U4 PCI−X QLogic: QLA200−E−SP4, 9, 24, FC−SW CLARiiON
DL580(G3)11, DL58511, ML370(G3)11, ML370(G4)11; v2.6.9−42.0.0.0.1.EL QLA210−E−SP4, 9, 24, QLE220−E−SP9, 14, AX100
15
Samsung SS140
55 Dell PowerEdge: 1800, 1850, 2800, 2850; Oracle Enterprise PCI, Emulex: LP1050−E1, 2, 9, 10, LP982−E1, 2, 9; FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model 8848); v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP3, 4, 9 AX100
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
56 HPQ Proliant: DL14511, DL380(G2)11, DL380(G3)11, Oracle Enterprise PCI, Emulex: LP1050−E1, 2, 10, LP982−E1, 2; FC−AL, EMC Y
DL380(G4)11, DL38011, DL38511, DL580(G2)11, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
DL580(G3)11, DL58511, ML370(G3)11, ML370(G4)11 v2.6.9−42.0.0.0.1.EL HPQ AD167A/FC2143 (LP1150)1, 2, 9, 12 AX100
57 HPQ Proliant: DL380(G4)11, DL38511, DL58511, Oracle Enterprise PCI, HPQ: AB429A/FC1143 (QLA2460)4, 9, 34, FC−AL, EMC Y
ML370(G4)11 Linux [32−Bit] 4 U4 PCI−X AE369A/FC1243 (QLA2462)4, 9, 34 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
58 IBM eServer: 325 (Model 8835), 326 (Model 8848) Oracle Enterprise PCI, IBM 24P0960 (QLA2340)3, 4, 9, 28 FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
59 HPQ Proliant: DL14511, DL380(G4)11, DL38511, Oracle Enterprise PCI, QLogic QLA2340−E−SP3, 4 FC−AL, EMC Y
DL580(G2)11, DL580(G3)11, DL58511, ML370(G3)11, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
ML370(G4)11; v2.6.9−42.0.0.0.1.EL AX100
Samsung SS140
60 Bull NovaScale 2320 Oracle Enterprise PCI−X Bull 2Gbps FC Mezzanine Card − Dual port FC−SW EMC Y
Linux [32−Bit] 4 U4 for NovaScale Blade Series: CLARiiON
v2.6.9−42.0.0.0.1.EL CFSN202−11004, 16, CFSN202−11004, 25; AX100
Bull 2Gbps FC Mezzanine Card − Dual port
mini for NovaScale Blade 2021:
CFSN202−21004, 16, CFSN202−21004, 25;
Bull SBEFCM (SFF) Mezzanine: HBA4, 16,
HBA4, 9, 25;
Bull SBEFCM4 (SFF) 4Gb Mezzanine HBA4,
13

11/02/2006 70 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
61 Digital Henge PowerBlade BS200L Oracle Enterprise PCI−X Digital Henge Digital Henge: SBEFCM44, 9, FC−SW EMC Y
Linux [32−Bit] 4 U4 13, SBEFCM4, 16, SBFCM4, 16; CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Intel (r) Fibre Channel Module
AHWFCMOD4, 9, 16
62 IBM BladeCenter: HS20 (Model 8843), HS21 (Model Oracle Enterprise PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)31 Linux [32−Bit] 4 U4 (26R0890)4, 9, 32, 33 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
63 IBM BladeCenter: HS21 (Model 8853)31, LS20 (Model Oracle Enterprise PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8850), LS21 (Model 7971), LS41 (Model 7972) Linux [32−Bit] 4 U4 (26R0890)4, 9, 33 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
64 IBM BladeCenter: HS20 (Model 8843), LS20 (Model 8850), Oracle Enterprise PCI−X IBM HS20 FC Exp Card (26K4841)3, 4, 9 FC−SW EMC Y
LS21 (Model 7971), LS41 (Model 7972) Linux [32−Bit] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
65 IBM BladeCenter HS20 (Model: 7981), 8678)36, 8832)36, Oracle Enterprise PCI−X IBM HS20 FC Exp Card: (13N2203)3, 4, 9, FC−SW EMC Y
8832−N1X), 8843); Linux [32−Bit] 4 U4 (48P7061)3, 4, 9 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
IBM BladeCenter: HS21 (Model 8853)31, HS40 (Model
8839)
66 IBM BladeCenter LS20 (Model 8850) Oracle Enterprise PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM FC−SW EMC Y
Linux [32−Bit] 4 U4 eServer LS203, 4, 9, SFF Exp Card CLARiiON
v2.6.9−42.0.0.0.1.EL (26K4841) for IBM eServer LS203, 4, 9 AX100
67 IBM BladeCenter HS20 (Model: 7981), 8678)36, 8832)36, Oracle Enterprise PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, 9, FC−SW EMC Y
8832−N1X), 8843); Linux [32−Bit] 4 U4 35, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−42.0.0.0.1.EL (26R0884)4, 9, 46 AX100
IBM BladeCenter: HS40 (Model 8839), LS20 (Model 8850)
1. Driver Version 8.0.16.27 Driver is integrated into the kernel.
2. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
3. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
5. BIOS 1.16
6. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. Firmware Version 2.50a8
8. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
9. SNIA HBA API Supported.
10. Firmware Version 1.91a5
11. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
12. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
13. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
15. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
16. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com
17. Firmware Version 2.50a6
18. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
20. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
22. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
23. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. BIOS 1.43
26. BIOS 1.70a3
27. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
28. This HBA is equivalent to the QLogic QLA2340.
29. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
31. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
32. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. BIOS 1.12
34. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
35. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
36. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
37. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
38. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
39. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
40. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
41. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
42. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
43. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
44. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
45. VxVM is not supported on servers booting from the array.
46. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

Oracle Enterprise Linux [AMD−64]

Oracle Enterprise Linux [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 IBM xSeries x3455 (7984) Oracle Enterprise Linux PCI Emulex: LP10000ExDC−E1, 8, 13, 26 , LP1050Ex−E1, 8, 13, 17 ; FC−AL, EMC Y
[AMD−64] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL IBM: 42C2069 (LPe11000)1, 8, 13, 25 , 42C2071 (LPe11002)1, 8, 13, AX100
24;

QLogic: QLE2360−E−SP1, 3, 7, QLE2460−E−SP1, 3, 6

11/02/2006 71 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
2 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y11, 12
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express Bladesystem (403621−B21)8, 9, 10 FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL AX100
3 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y32
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express Bladesystem (403621−B21)8, 10, 31 FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL AX100
4 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express (403619−B21)3, 27 FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL AX100
5 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express Bladesystem (403621−B21)8, 10, 31, QLogic QMH2462 4Gb FC FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL HBA for HP c−Class Bladesystem (403619−B21)3, 27 AX100
6 Dell PowerEdge 6950; Oracle Enterprise Linux PCI Emulex LP1050−E1, 8, 13, 28 ; FC−AL, EMC Y
IBM xSeries x3755 (8877) [AMD−64] 4 U4 Express, QLogic QLA2340−E−SP1, 2, 3 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
7 Dell PowerEdge 6950 Oracle Enterprise Linux PCI Emulex: LP101−E1, 8, 13, 17 , LP1050Ex−E1, 8, 13, 17 , LP982−E1, 8, FC−AL, EMC Y
[AMD−64] 4 U4 Express, 13, LPe111−E1, 8, 9, 13, LPe1150−E1, 8, 13, 24 ; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
QLogic: QLA200−E−SP1, 3, 4, QLA210−E−SP1, 3, 4,
QLE220−E−SP1, 20, 21, QLE2360−E−SP1, 3, 29, 30 ,
QLE2460−E−SP1, 3, 23
8 IBM xSeries x3755 (8877) Oracle Enterprise Linux PCI IBM: 24P0960 (QLA2340)1, 2, 3, 5, 24P8053 (QLA2342)1, 2, 3; FC−AL, EMC Y
[AMD−64] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X QLogic: QLA2460−E−SP1, 3, 6, QLE2360−E−SP1, 3, 7, AX100
QLE2460−E−SP1, 3, 6
9 Sun: V20z, V40z, x4100, x4200 Oracle Enterprise Linux PCI−X Emulex: LP1050−E1, 8, 13, 28 , LP982−E1, 8, 13; FC−AL, EMC Y
[AMD−64] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP1, 2, 3 AX100
10 HPQ Proliant BL45p Oracle Enterprise Linux PCI−X HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
[AMD−64] 4 U4 HBA − 394588−B218, 13, 14, 15 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
11 Sun: x4100, x4200 Oracle Enterprise Linux PCI−X QLogic QLA2460−E−SP1, 3, 23 FC−AL, EMC Y
[AMD−64] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
12 HPQ Proliant: BL25p, BL35p Oracle Enterprise Linux PCI−X16 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
[AMD−64] 4 U4 HBA − 394588−B218, 13, 14, 15 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
13 HPQ Proliant: DL14522, Oracle Enterprise Linux PCI, Emulex: LP101−E1, 8, 13, 17 , LP1050−E8, 13, 28, LP982−E8, 13; FC−AL, EMC Y
DL38522, DL58522 [AMD−64] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL HPQ AD167A/FC2143 (LP1150)1, 8, 13, 37 ; AX100
QLogic: QLA200−E−SP1, 3, 4, QLA210−E−SP1, 3, 4,
QLA2340−E−SP2, 3, QLE220−E−SP1, 19, 20, 21
14 IBM eServer: 325 (Model 8835), Oracle Enterprise Linux PCI, Emulex: LP1050−E1, 8, 13, 28 , LP982−E1, 8, 13; FC−AL, EMC Y
326 (Model 8848) [AMD−64] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL IBM 24P0960 (QLA2340)1, 2, 3, 5; AX100
QLogic QLA2340−E−SP1, 2, 3
15 IBM BladeCenter LS20 (Model Oracle Enterprise Linux PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)1, 8, 33, FC−SW EMC Y
8850) [AMD−64] 4 U4 34, LP1005DC FC Exp Card1, 8, 13, 36 ; CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
IBM HS20 4GB: SFF FC Exp Card (26R0890)1, 3, 35, Standard FC
Exp Card (26R0884)1, 3, 18;
IBM HS20 FC Exp Card: (13N2203) for IBM eServer LS201, 2, 3,
(26K4841)1, 2, 3;
IBM HS20 FC SFF Exp Card (26K4841) for IBM eServer LS201, 2, 3
1. SNIA HBA API Supported.
2. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
4. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. This HBA is equivalent to the QLogic QLA2340.
6. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. Driver Version 8.0.16.27 Driver is integrated into the kernel.
9. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
12. VxVM is not supported on servers booting from the array.
13. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
14. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
15. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
16. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
17. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
18. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Driver/BIOS are available at http://www.qlogic.com
20. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
21. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
22. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
23. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. Firmware Version 2.50a6
25. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
26. Firmware Version 1.91.a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
27. BIOS 1.16
28. Firmware Version 1.91a5
29. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
30. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
31. Firmware Version 2.50a8
32. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
33. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
34. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. BIOS 1.12
36. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
37. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

11/02/2006 72 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [EM64T]

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, 2800, 2850, Oracle Enterprise Linux PCI Emulex LP101−E2, 11, 13, 23 ; FC−AL, EMC Y
6800, 6850; [EM64T] 4 U4 Express QLogic: QLA200−E−SP1, 2, 15, QLA210−E−SP1, 2, 15 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge Revo: JS1400, JS2400
2 Dell PowerEdge: 1800, 2800, 2850 Oracle Enterprise Linux PCI Emulex LP1050−E2, 11, 12, 13 ; FC−AL, EMC Y
[EM64T] 4 U4 Express QLogic QLA2340−E−SP1, 2, 7 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
3 Dell PowerEdge: 1800, 1850, 1950, Oracle Enterprise Linux PCI Emulex LP1050Ex−E2, 11, 13, 23 FC−AL, EMC Y
2800, 2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)14;
LangChao: NC3000, NC3500,
NF500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
4 Dell PowerEdge: 1800, 2800, 2850; Oracle Enterprise Linux PCI Emulex LP982−E2, 11, 13 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
Samsung ZSS230 v2.6.9−42.0.0.0.1.EL AX100
5 Samsung ZSS230 Oracle Enterprise Linux PCI Emulex: LP101−E11, 13, 23, LP1050−E11, 12, 13, LP982−E11, FC−AL, EMC Y
[EM64T] 4 U4 Express 13; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
QLogic QLA2340−E−SP1, 7
6 Dell PowerEdge: 1800, 1850, 1950, Oracle Enterprise Linux PCI Emulex: LPe111−E2, 11, 13, 41 , LPe1150−E2, 11, 13, 22 FC−AL, EMC Y
2800, 2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400,
JS2400;
HPQ Proliant: DL360(G4)17,
DL380(G4)17, DL580(G3)17,
ML350(G4)17, ML370(G4)17;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
7 HPQ Proliant: DL360(G4)17, Oracle Enterprise Linux PCI HPQ: A8002A/FC2142SR (LPe1150)2, 11, 13, 27 , FC−AL, EMC Y
DL380(G4)17, DL580(G3)17, [EM64T] 4 U4 Express AD167A/FC2143 (LP1150)2, 11, 13, 42 FC−SW CLARiiON
ML350(G4)17, ML370(G4)17 v2.6.9−42.0.0.0.1.EL AX100
8 Dell PowerEdge 1950 Oracle Enterprise Linux PCI QLogic QLE220−E−SP2, 5, 6 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
9 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise Linux PCI QLogic QLE220−E−SP2, 5, 6, 16 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
10 Dell PowerEdge: 1800, 1850, 1950, Oracle Enterprise Linux PCI QLogic QLE2360−E−SP1, 2, 3, 4 FC−AL, EMC Y
2800, 2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)14;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
11 Digital Henge INNO: HR−4850, Oracle Enterprise Linux PCI QLogic QLE2360−E−SP1, 3, 4 FC−AL, EMC Y
HR−6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
LangChao: NC3000, NC3500,
NF500, NF520;
Samsung ZSS230
12 Dell PowerEdge: 1800, 1850, 1950, Oracle Enterprise Linux PCI QLogic QLE2460−E−SP1, 2, 35 FC−AL, EMC Y
2800, 2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400,
JS2400;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 73 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
13 Dell PowerEdge: 2900, 2950, 6800, Oracle Enterprise Linux PCI Emulex LP101−E2, 11, 13, 23 ; FC−AL, EMC Y
6850; [EM64T] 4 U4 Express, QLogic: QLA200−E−SP1, 2, 15, QLA210−E−SP1, 2, 15 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
Digital Henge Revo: AS1500,
AS1550, AS2500;
HPQ Proliant ML350(G4)17;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
14 Dell PowerEdge: 2900, 2950, 6800, Oracle Enterprise Linux PCI Emulex LP1050−E2, 11, 12, 13 ; FC−AL, EMC Y
6850; [EM64T] 4 U4 Express, QLogic QLA2340−E−SP1, 2, 7 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
Digital Henge Revo: AS1500,
AS1550, AS2500;
IBM xSeries: x3550 (7978), x3650
(7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
15 Dell PowerEdge: 2900, 2950, 6800, Oracle Enterprise Linux PCI Emulex LP982−E2, 11, 13 FC−AL, EMC Y
6850; [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
16 HPQ Proliant ML350(G4)17 Oracle Enterprise Linux PCI Emulex: LP1050−E11, 12, 13, LP982−E11, 13; FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)1, 2, 30, AD167A/FC2143 AX100
(LP1150)2, 11, 13, 42 , AE369A/FC1243 (QLA2462)1, 2, 30;
QLogic: QLA2340−E−SP1, 7, QLE220−E−SP2, 5, 6, 16
17 Dell PowerEdge: 2900, 2950; Oracle Enterprise Linux PCI Emulex: LP1050Ex−E2, 11, 13, 23 , LPe111−E2, 11, 13, 41 , FC−AL, EMC Y
[EM64T] 4 U4 Express, LPe1150−E2, 11, 13, 22 ; FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.9−42.0.0.0.1.EL PCI−X AX100
AS1550, AS2500; QLogic: QLE2360−E−SP1, 2, 3, 4, QLE2460−E−SP1, 2, 35
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
18 IBM xSeries: x3550 (7978), x3650 Oracle Enterprise Linux PCI IBM: 24P0960 (QLA2340)1, 2, 7, 8, 24P8053 (QLA2342)1, 2, 7; FC−AL, EMC Y
(7979) [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X QLogic: QLA2460−E−SP1, 2, 9, QLE2360−E−SP1, 2, 10, AX100
QLE2460−E−SP1, 2, 9
19 NEC Express 5800: 120Li, 120Rg−1, Oracle Enterprise Linux PCI NEC: N8190−120 (LP1050)11, 12, 20, 21 , N8190−127 FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 [EM64T] 4 U4 Express, (LPe1150)11, 20, 21, 22 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
20 Dell PowerEdge: 1850, 1900, 2850, Oracle Enterprise Linux PCI QLogic QLE220−E−SP2, 5, 6 FC−AL, EMC Y
2900, 2950, 6800, 6850; [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
21 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise Linux PCI Emulex: LP101−E2, 11, 13, 23 , LP1050−E11, 12, 13, LP982−E11, FC−AL, EMC Y
[EM64T] 4 U4 Express, 13; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X18 AX100
QLogic: QLA200−E−SP1, 2, 15, QLA210−E−SP1, 2, 15,
QLA2340−E−SP1, 7, QLE220−E−SP2, 5, 6, 16
22 Dell PowerEdge 1855 Oracle Enterprise Linux PCI−X Dell: 2342M1, 7, LPe1105−M2, 11, 13, 22 , QME24621, 2, 34 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
23 Dell PowerEdge: 1850, 1950; Oracle Enterprise Linux PCI−X Emulex LP101−E2, 11, 13, 23 ; FC−AL, EMC Y
[EM64T] 4 U4 QLogic QLA200−E−SP1, 2, 15 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX100
HPQ Proliant DL360(G4)17;
LangChao NF420;
Lenovo SureServer: R630 6004,
T630 6003
24 Digital Henge INNO: HR−4850, Oracle Enterprise Linux PCI−X Emulex LP101−E11, 13, 23 FC−AL, EMC Y
HR−6850; [EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
LangChao: NC3000, NC3500,
NF500, NF520
25 Dell PowerEdge: 1850, 1950; Oracle Enterprise Linux PCI−X Emulex LP1050−E2, 11, 12, 13 ; FC−AL, EMC Y
[EM64T] 4 U4 QLogic QLA2340−E−SP1, 2, 7 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX100
IBM xSeries: x255, x336 (8837)14,
x346 (8840)14;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500, NF520;
Lenovo SureServer R630: 6003,
6004;
Lenovo SureServer: R650, T630
6003, T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230

11/02/2006 74 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
26 Dell PowerEdge 1850; Oracle Enterprise Linux PCI−X Emulex LP982−E2, 11, 13 FC−AL, EMC Y
Digital Henge INNO: HR−4850, [EM64T] 4 U4 FC−SW CLARiiON
HR−6850; v2.6.9−42.0.0.0.1.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)14,
x346 (8840)14;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500, NF520;
Lenovo SureServer R630: 6003,
6004;
Lenovo SureServer: R650, T630
6003, T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230
27 Digital Henge INNO: HR−4850, Oracle Enterprise Linux PCI−X Emulex: LP1050−E11, 12, 13, LP982−E11, 13 FC−AL, EMC Y
HR−6850; [EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
HPQ Proliant DL360(G4)17;
LangChao: NC3000, NC3500,
NF500, NF520
28 HPQ Proliant BL460c: Oracle Enterprise Linux PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y37, 38
(416653−B21), (416654−B21), [EM64T] 4 U4 Bladesystem (403621−B21)11, 39, 40 FC−SW CLARiiON
(416655−B21), (416656−B21), v2.6.9−42.0.0.0.1.EL AX100
(432636−B21);
HPQ Proliant BL480c:
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
29 HPQ Proliant BL460c: Oracle Enterprise Linux PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(416653−B21), (416654−B21), [EM64T] 4 U4 Bladesystem (403619−B21)1, 36 FC−SW CLARiiON
(416655−B21), (416656−B21), v2.6.9−42.0.0.0.1.EL AX100
(432636−B21);
HPQ Proliant BL480c:
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
30 HPQ Proliant DL360(G4)17 Oracle Enterprise Linux PCI−X HPQ: AB429A/FC1143 (QLA2460)1, 2, 30, AD167A/FC2143 FC−AL, EMC Y
[EM64T] 4 U4 (LP1150)2, 11, 13, 42 , AE369A/FC1243 (QLA2462)1, 2, 30 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
31 NEC Express 5800: 120Lh, Oracle Enterprise Linux PCI−X NEC N8190−120 (LP1050)11, 13, 21, 23 FC−AL, EMC Y
120Re−1, 120Rf−1, 120Rg−2, [EM64T] 4 U4 FC−SW CLARiiON
120Rh−2, 140He, 140Rd−4 v2.6.9−42.0.0.0.1.EL AX100
32 NEC Express 5800: 140He, 140Rd−4 Oracle Enterprise Linux PCI−X NEC N8190−127 (LPe1150)11, 13, 21, 27 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
33 Dell PowerEdge 1850; Oracle Enterprise Linux PCI−X QLogic QLA210−E−SP1, 2, 15 FC−AL, EMC Y
Digital Henge SH4500R4; [EM64T] 4 U4 FC−SW CLARiiON
HPQ Proliant DL360(G4)17; v2.6.9−42.0.0.0.1.EL AX100
LangChao NF420;
Lenovo SureServer: R630 6004,
T630 6003
34 Digital Henge INNO: HR−4850, Oracle Enterprise Linux PCI−X QLogic QLA2340−E−SP1, 7 FC−AL, EMC Y
HR−6850; [EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
Digital Henge SH4500R4;
HPQ Proliant DL360(G4)17;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500, NF520;
Lenovo SureServer: R630 6004,
T630 6003
35 Digital Henge SH4500R4; Oracle Enterprise Linux PCI−X QLogic QLE220−E−SP2, 5, 6, 16 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 [EM64T] 4 U4 FC−SW CLARiiON
S2, TX200 S2, TX300 S2; v2.6.9−42.0.0.0.1.EL AX100
HPQ Proliant DL360(G4)17;
LangChao NF420;
Lenovo SureServer: R630 6004,
T630 6003
36 HPQ Proliant BL20p: (G3), (G4) Oracle Enterprise Linux PCI−X33 HPQ Emulex−based BL20p (G3) Fibre Channel Mezzanine FC−AL, EMC Y
[EM64T] 4 U4 HBA − 394757−B2111, 13, 31, 32 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
37 Dell PowerEdge 1955 Oracle Enterprise Linux PCI, PCI Dell: LPe1105−M2, 11, 13, 22 , QME24621, 2, 34 FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
38 HPQ Proliant DL380(G5) Oracle Enterprise Linux PCI, PCI Emulex: LP101−E2, 11, 13, 23 , LP1050−E11, 12, 13, LP982−E11, FC−AL, EMC Y
[EM64T] 4 U4 Express, 13; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)1, 2, 30, AE369A/FC1243
(QLA2462)1, 2, 30;
QLogic: QLA200−E−SP1, 2, 15, QLA210−E−SP1, 2, 15,
QLA2340−E−SP1, 7
39 HPQ Proliant: DL380(G5), Oracle Enterprise Linux PCI, PCI Emulex: LPe111−E2, 11, 13, 41 , LPe1150−E2, 11, 13, 22 ; FC−AL, EMC Y
DL580(G4) [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: A8002A/FC2142SR (LPe1150)2, 11, 13, 27 , AX100
AD167A/FC2143 (LP1150)2, 11, 13, 42 , AE311A/FC1142SR
(QLE2460)1, 2, 35, AE312A/FC1242SR (QLE2462)1, 2, 35;
QLogic: QLE2460−E−SP1, 2, 35, QLE2462−E−SP1, 2, 35

11/02/2006 75 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
40 Dell PowerEdge: 1800, 2800 Oracle Enterprise Linux PCI, PCI QLogic QLE220−E−SP2, 5, 6 FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
41 HPQ Proliant: DL380(G5), Oracle Enterprise Linux PCI, PCI QLogic QLE220−E−SP2, 5, 6, 16 FC−AL, EMC Y
DL580(G3)17, DL580(G4) [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX100
42 HPQ Proliant: DL380(G4)17, Oracle Enterprise Linux PCI, Emulex: LP101−E2, 11, 13, 23 , LP1050−E11, 12, 13, LP982−E11, FC−AL, EMC Y
ML370(G4)17 [EM64T] 4 U4 PCI−X 13; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
HPQ: AB429A/FC1143 (QLA2460)1, 2, 30, AD167A/FC2143
(LP1150)2, 11, 13, 42 , AE369A/FC1243 (QLA2462)1, 2, 30;
QLogic: QLA200−E−SP1, 2, 15, QLA210−E−SP1, 2, 15,
QLA2340−E−SP1, 7, QLE220−E−SP2, 5, 6, 16
43 Dell PowerEdge: 1800, 1850, 2800, Oracle Enterprise Linux PCI, Emulex: LP1050−E2, 11, 12, 13 , LP982−E2, 11, 13; FC−AL, EMC Y
2850; [EM64T] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP1, 2, 7 AX100
IBM xSeries: x365, x440, x445
(8870);
Samsung: ES470, ES570, SS140
44 IBM BladeCenter HS20 (Model 8843) Oracle Enterprise Linux PCI−X IBM HS20 FC Exp Card (26K4841)1, 2, 7 FC−SW EMC Y
[EM64T] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
45 IBM BladeCenter HS20 (Model: Oracle Enterprise Linux PCI−X IBM HS20 FC Exp Card: (13N2203)1, 2, 7, (48P7061)1, 2, 7 FC−SW EMC Y
8832−N1X), 8843); [EM64T] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
IBM BladeCenter HS21 (Model
8853)24
46 IBM BladeCenter: HS20 (Model Oracle Enterprise Linux PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)2, FC−SW EMC Y
8843), HS21 (Model 8853)24 [EM64T] 4 U4 11, 25, 26 , HS20 4GB SFF FC Exp Card (26R0890)1, 2, 28, 29 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
47 IBM BladeCenter HS20 (Model: Oracle Enterprise Linux PCI−X IBM: Emulex LP1005DC FC Exp Card2, 11, 13, 19 , HS20 4GB FC−SW EMC Y
8832−N1X), 8843) [EM64T] 4 U4 Standard FC Exp Card (26R0884)1, 2, 43 CLARiiON
v2.6.9−42.0.0.0.1.EL AX100
1. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
2. SNIA HBA API Supported.
3. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
6. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
7. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. This HBA is equivalent to the QLogic QLA2340.
9. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. Driver Version 8.0.16.27 Driver is integrated into the kernel.
12. Firmware Version 1.91a5
13. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
14. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
15. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver/BIOS are available at http://www.qlogic.com
17. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
18. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
19. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
20. BIOS 1.70a3
21. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
22. Firmware Version 2.50a6
23. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
25. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
26. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
27. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
28. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
29. BIOS 1.12
30. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
31. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
33. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
34. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
35. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. BIOS 1.16
37. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
38. VxVM is not supported on servers booting from the array.
39. Firmware Version 2.50a8
40. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
41. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
43. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

Red Flag DC Server [32−Bit]

11/02/2006 76 CLARiiON AX100


CLARiiON AX100

Red Flag DC Server [32−Bit]


Host Bus Storage External
No. Host System Operating System Host Bus Adapter Topology Array Boot
1 HPQ Proliant: DL3207, DL360(G2)7, DL3607, DL380(G2)7, DL380(G3)7, DL3807, Red Flag DC Server PCI QLogic FC−AL, EMC Y
DL580(G2)7, DL5807, ML350(G2)7, ML350(G3)7, ML3507, ML370(G2)7, ML3707, [32−Bit] 5.0 SP1 QLE220−E−SP2, FC−SW CLARiiON
ML530(G2)7, ML530(G3)7, ML5307, ML5707, ML7507 v2.6.9−34.21AX5, 6 8, 9, 10 AX100
2 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Red Flag DC Server PCI Emulex FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express LPe111−E1, 2, FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.21AX5, 6 3, 4 AX100
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)7, DL380(G4)7, DL580(G3)7, ML350(G4)7, ML370(G4)7;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
3 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 8, 9, 10 AX100
4 Dell PowerEdge 1950 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 9, 10 AX100
5 Dell PowerEdge: 2900, 2950, 6950; Red Flag DC Server PCI Emulex FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, LPe111−E1, 2, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX5, 6 PCI−X 3, 4 AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)7 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 PCI−X 8, 9, 10 AX100
7 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, 6950; Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP2, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX5, 6 PCI−X 9, 10 AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
8 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 PCI−X11 8, 9, 10 AX100
9 Digital Henge SH4500R4; Red Flag DC Server PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; [32−Bit] 5.0 SP1 QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 8, 9, 10 AX100
HPQ Proliant: BL40p, DL360(G3)7, DL360(G4)7, DL5607, DL7407, DL760 (G2)7,
DL7607, ML570(G2)7;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
10 Dell PowerEdge: 1800, 2800 Red Flag DC Server PCI, PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 PCI−X 9, 10 AX100
11 HPQ Proliant: DL1457, DL380(G2)7, DL380(G3)7, DL380(G4)7, DL3807, DL3857, Red Flag DC Server PCI, QLogic FC−AL, EMC Y
DL580(G2)7, DL580(G3)7, DL5857, ML370(G3)7, ML370(G4)7; [32−Bit] 5.0 SP1 PCI−X QLE220−E−SP2, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 8, 9, 10 AX100
Samsung SS140
1. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. SNIA HBA API Supported.
3. Driver Version 8.0.16.18 Driver is integrated into the kernel.
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Native multipathing is not supported on boot−from−SAN configurations.
6. Based on Asianux 2.0.
7. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
8. Driver/BIOS are available at http://www.qlogic.com
9. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
10. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Red Flag DC Server [AMD64]

Red Flag DC Server [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge 6950 Red Flag DC Server [AMD64] 5.0 SP1 PCI Express, Emulex LPe111−E1, 10, 11, 13 ; FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX6, 7 PCI−X QLogic QLE220−E−SP1, 2, 3 FC−SW AX100
2 Sun: x4100, x4200 Red Flag DC Server [AMD64] 5.0 SP1 PCI−X Emulex: LP1050−E1, 10, 11, 12 , FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX6, 7 LP982−E1, 10, 11; FC−SW AX100
QLogic QLA2340−E−SP1, 8, 9
3 HPQ Proliant: DL1455, Red Flag DC Server [AMD64] 5.0 SP1 PCI, PCI−X QLogic QLE220−E−SP1, 2, 3, 4 FC−AL, EMC CLARiiON Y
DL3855, DL5855 v2.6.9−34.21AX6, 7 FC−SW AX100

11/02/2006 77 CLARiiON AX100


CLARiiON AX100

1. SNIA HBA API Supported.


2. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
3. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
4. Driver/BIOS are available at http://www.qlogic.com
5. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
6. Native multipathing is not supported on boot−from−SAN configurations.
7. Based on Asianux 2.0.
8. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
9. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Driver Version 8.0.16.18 Driver is integrated into the kernel.
11. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
12. Firmware Version 1.91a5
13. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

Red Flag DC Server [EM64T]

Red Flag DC Server [EM64T]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, Red Flag DC Server [EM64T] 5.0 PCI Express Emulex LPe111−E1, FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX5, 6 2, 3, 4 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
2 Dell PowerEdge 1950 Red Flag DC Server [EM64T] 5.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 QLE220−E−SP2, 7, 8 FC−SW CLARiiON
AX100
3 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server [EM64T] 5.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 QLE220−E−SP2, 7, 8, FC−SW CLARiiON
10 AX100
4 Dell PowerEdge: 2900, 2950; Red Flag DC Server [EM64T] 5.0 PCI Express, Emulex LPe111−E1, FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 PCI−X 2, 3, 4 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; AX100
Intel: SR1500/S5000PAL, SR2500/S5000PAL
5 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, Red Flag DC Server [EM64T] 5.0 PCI Express, QLogic FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX5, 6 PCI−X QLE220−E−SP2, 7, 8 FC−SW CLARiiON
AX100
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)9 Red Flag DC Server [EM64T] 5.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 PCI−X QLE220−E−SP2, 7, 8, FC−SW CLARiiON
10 AX100
7 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server [EM64T] 5.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 PCI−X11 QLE220−E−SP2, 7, 8, FC−SW CLARiiON
10 AX100
8 Digital Henge SH4500R4; Red Flag DC Server [EM64T] 5.0 PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, SP1 v2.6.9−34.21AX5, 6 QLE220−E−SP2, 7, 8, FC−SW CLARiiON
TX300 S2; 10 AX100
HPQ Proliant DL360(G4)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003
9 Dell PowerEdge: 1800, 2800 Red Flag DC Server [EM64T] 5.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 Express, PCI−X QLE220−E−SP2, 7, 8 FC−SW CLARiiON
AX100
10 HPQ Proliant DL580(G3)9 Red Flag DC Server [EM64T] 5.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 Express, PCI−X QLE220−E−SP2, 7, 8, FC−SW CLARiiON
10 AX100
11 HPQ Proliant: DL380(G4)9, ML370(G4)9 Red Flag DC Server [EM64T] 5.0 PCI, PCI−X QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX5, 6 QLE220−E−SP2, 7, 8, FC−SW CLARiiON
10 AX100
1. Driver Version 8.0.16.18 Driver is integrated into the kernel.
2. SNIA HBA API Supported.
3. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Native multipathing is not supported on boot−from−SAN configurations.
6. Based on Asianux 2.0.
7. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
8. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
9. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Driver/BIOS are available at http://www.qlogic.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Red Hat RHEL [32−Bit]

11/02/2006 78 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 HPQ Proliant BL20p (G2) Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−20.EL7 Adapter for HP Proliant BL20p (G2) CLARiiON
300874−B2110, 38 AX100
2 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−20.EL7 Adapter for HP Proliant BL20p (G3) CLARiiON
361426−B2110, 38 AX100
3 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−20.EL7 Adapter for HP Proliant CLARiiON
BL30p/BL35p 354054−B2110, 38 AX100
4 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC Y
v2.4.21−40.EL7, 25 Adapter for HP Proliant BL20p (G3) CLARiiON
361426−B2110, 29 AX100
5 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC Y
v2.4.21−40.EL7, 25 Adapter for HP Proliant CLARiiON
BL30p/BL35p 354054−B2110, 29 AX100
6 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC Y
v2.4.21−47.EL7, 25 Adapter for HP Proliant BL20p (G3) CLARiiON
361426−B2110, 24 AX100
7 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC Y
v2.4.21−47.EL7, 25 Adapter for HP Proliant CLARiiON
BL30p/BL35p 354054−B2110, 24 AX100
8 HPQ Proliant BL20p (G2) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, Adapter for HP Proliant BL20p (G2) CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES 300874−B21 5, 10, 65 AX100
v2.4.21−15.0.4.EL7
9 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, Adapter for HP Proliant BL20p (G3) CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES 361426−B215, 10, 65 AX100
v2.4.21−15.0.4.EL7
10 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, Adapter for HP Proliant CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES BL30p/BL35p 354054−B215, 10 AX100
v2.4.21−15.0.4.EL7
11 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Adapter for HP Proliant BL20p (G3) CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES 361426−B214, 5, 10 AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
12 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Adapter for HP Proliant CLARiiON
7, 8
U4+ AS/ES v2.4.21−27.0.2.EL , U4+ AS/ES BL30p/BL35p 354054−B215, 10 AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
13 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Adapter for HP Proliant BL20p (G3) CLARiiON
361426−B2110, 29 AX100
14 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Adapter for HP Proliant CLARiiON
BL30p/BL35p 354054−B2110, 29 AX100
15 HPQ Proliant BL35p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Adapter for HP Proliant CLARiiON
BL30p/BL35p 354054−B2110, 29 AX100
16 Unisys ES7000/460 [64−Bit] Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Unisys FCH752323−PCX16, 19, 43 FC−AL EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
17 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U2 AS/ES PCI, Emulex: LP101−E16, 19, 62, FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−15.EL7 PCI−X LP1050−E16, 18, 62 FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL580(G2)13, DL580(G3)13, DL58513,
ML370(G3)13
18 HPQ Proliant: DL14513, DL58513 Red Hat RHEL [32−Bit] 3.0 U2 AS/ES PCI, QLogic QLA200−E−SP14, 15, 65 FC−AL, EMC N1, 2
v2.4.21−15.EL7 PCI−X FC−SW CLARiiON
AX100
19 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI QLogic: QLA200−E−SP14, FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7 QLA2340−E−SP11, 15 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
20 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI−X Emulex: LP101−E16, 19, 62, FC−AL, EMC N1, 2
1800, 2800, 2850; v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7 LP1050−E16, 18, 62, LP982−E16, 62 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
21 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI−X QLogic QLA200−E−SP14 FC−AL, EMC N1, 2
DL56013, DL74013, DL760 (G2)13, v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7 FC−SW CLARiiON
DL76013, ML570(G2)13 AX100
22 Dell PowerEdge 2850; Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI−X QLogic QLA2340−E−SP11, 15 FC−AL, EMC N1, 2
HPQ Proliant: BL40p, DL360(G3)13, v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7 FC−SW CLARiiON
DL360(G4)13, DL56013, DL74013, AX100
DL760 (G2)13, DL76013, ML570(G2)13
23 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI, QLogic QLA200−E−SP14 FC−AL, EMC N1, 2
DL380(G3)13, DL38013, DL580(G2)13, v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7 PCI−X FC−SW CLARiiON
DL580(G3)13, ML370(G3)13 AX100

11/02/2006 79 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
24 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI−X Fujitsu Siemens FC−AL, EMC N1, 2
RX300 S2, TX200 S2, TX300 S2 v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7; S26361−F2843−E1 (Emulex FC−SW CLARiiON
LP9802)16, 32, 61 AX100
Red Hat RHEL [32−Bit] 3.0 U4 AS/ES
v2.4.21−27.EL7
25 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI, Emulex: LP101−E16, 19, 62, FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7, PCI−X LP1050−E16, 18, 62 FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−15.0.4.EL7 AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13
26 HPQ Proliant: DL14513, DL38513, Red Hat RHEL [32−Bit] 3.0 U2+ AS/ES: PCI, QLogic QLA200−E−SP14, 15, 65 FC−AL, EMC N1, 2
DL58513 v2.4.21−15.0.2.EL7, v2.4.21−15.0.3.EL7, PCI−X FC−SW CLARiiON
v2.4.21−15.0.4.EL7 AX100
27 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Emulex LP101−E16, 19, 60 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−20.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013;
IBM xSeries: x225, x230, x232, x240,
x250, x330, x335, x340 (4500R), x342,
x350 (6000R), x370
28 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Emulex LP1050−E16, 18, 20 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−20.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: 850013, DL32013,
DL360(G2)13, DL36013, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
29 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Emulex LP982−E16, 20 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−20.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
30 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Fujitsu Siemens BX600−FC22Q11, FC−AL, EMC N1, 2
S2F34, S234; v2.4.21−20.EL7 27, 33, 38 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: BX62034,
BX66034
31 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 60 FC−AL, EMC N1, 2
2850 v2.4.21−20.EL7 Express FC−SW CLARiiON
AX100
32 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Emulex: LP101−E16, 19, 60, FC−AL, EMC N1, 2
v2.4.21−20.EL7 Express, LP1050−E16, 18, 20, LP982−E16, 20 FC−SW CLARiiON
PCI−X AX100
33 NEC Express 5800 110Rg−1 Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
v2.4.21−20.EL7 Express, 35, 60 FC−SW CLARiiON
PCI−X AX100
34 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI Emulex: LP101−E16, 19, 60, FC−AL, EMC N1, 2
v2.4.21−20.EL7 Express, LP1050−E16, 18, 20, LP982−E16, 20 FC−SW CLARiiON
PCI−X 67 AX100
35 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X Emulex LP101−E16, 19, 60 FC−AL, EMC N1, 2
1800, 2600, 2650, 2800, 2850, 4600, v2.4.21−20.EL7 FC−SW CLARiiON
6600, 6650; AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x235, x255, x360, x365,
x440;
Samsung: SS370, SS3840
36 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X Emulex LP101−E16, 32, 60 FC−AL, EMC N1, 2
RX300 S2, TX200 S2, TX300 S2 v2.4.21−20.EL7 FC−SW CLARiiON
AX100
37 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X Emulex: LP1050−E16, 18, 20, FC−AL, EMC N1, 2
1800, 2600, 2650, 2800, 2850, 4600, v2.4.21−20.EL7 LP982−E16, 20 FC−SW CLARiiON
6600, 6650; AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
Samsung: SS370, SS3840
38 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X HPQ Dual−port Fibre Channel FC−AL, EMC N1, 2
v2.4.21−20.EL7 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 38 AX100
39 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL, EMC N1, 2
v2.4.21−20.EL7 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 38 AX100

11/02/2006 80 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
40 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI, Emulex LP101−E16, 19, 60 FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−20.EL7 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13;
IBM xSeries: x345 (8670), x445 (8870)
41 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI, Emulex LP1050−E16, 18, 20 FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−20.EL7 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13
42 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI, Emulex LP982−E16, 20 FC−AL, EMC N1, 2
HPQ Proliant: DL380(G2)13, v2.4.21−20.EL7 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL580(G2)13, DL580(G3)13,
ML370(G3)13, ML370(G4)13
43 HPQ Proliant: DL14513, DL38513, Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI, QLogic QLA200−E−SP14, 38 FC−AL, EMC N1, 2
DL58513; v2.4.21−20.EL7 PCI−X FC−SW CLARiiON
AX100
IBM xSeries: x345 (8670), x445 (8870)
44 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−27.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013;
IBM xSeries: x225, x230, x232, x240,
x250, x330, x335, x340 (4500R), x342,
x350 (6000R), x370
45 HPQ Proliant: 850013, DL32013, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI Emulex LP1050−E16, 17, 18 FC−AL, EMC N1, 2
DL360(G2)13, DL36013, DL58013, v2.4.21−27.EL7 FC−SW CLARiiON
ML350(G2)13, ML350(G3)13, ML35013, AX100
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013;
IBM xSeries: x225, x230, x232, x240,
x250, x330, x335, x340 (4500R), x342,
x350 (6000R), x370
46 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI Emulex LP982−E16, 17 FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.4.21−27.EL7 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013;
IBM xSeries: x225, x230, x232, x240,
x250, x330, x335, x342, x350 (6000R),
x370
47 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI Fujitsu Siemens BX600−FC22Q5, FC−AL, EMC N1, 2
S2F34, S234; v2.4.21−27.EL7 11, 27, 33 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: BX62034,
BX66034
48 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI QLogic QLA200−E−SP4, 14, 15 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−27.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
49 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI QLogic QLA2340−E−SP11, 12 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−27.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AX100
50 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI QLogic QLA2340−E−SP11, 12, 38 FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−27.EL7 FC−SW CLARiiON
x350 (6000R), x370 AX100
51 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI−X Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
2600, 2650, 2850, 4600, 6600, 6650; v2.4.21−27.EL7 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x235, x255, x360, x365,
x440;
Samsung: SS370, SS3840
52 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI−X Emulex LP101−E16, 19, 20 FC−AL, EMC N1, 2
v2.4.21−27.EL7 FC−SW CLARiiON
AX100
53 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI−X Emulex: LP1050−E16, 17, 18, FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL74013, v2.4.21−27.EL7 LP982−E16, 17 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13; AX100
IBM xSeries: x235, x255, x360, x365,
x440

11/02/2006 81 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
54 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI−X QLogic QLA200−E−SP4, 14, 15 FC−AL, EMC N1, 2
2600, 2650, 2850, 4600, 6600, 6650; v2.4.21−27.EL7 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL56013, DL74013, DL760 (G2)13,
DL76013, ML570(G2)13
55 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI−X QLogic QLA2340−E−SP11, 12 FC−AL, EMC N1, 2
2600, 2650, 2850, 4600, 6600, 6650; v2.4.21−27.EL7 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: RX200 S2,
RX600 S2, TX600 S2
56 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI−X QLogic QLA2340−E−SP11, 12, 38 FC−AL, EMC N1, 2
RX600 S2, TX600 S2; v2.4.21−27.EL7 FC−SW CLARiiON
AX100
IBM xSeries: x235, x255, x346
(8840)46, x360, x365, x440
57 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI, Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−27.EL7 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13;
IBM xSeries: x345 (8670), x445 (8870)
58 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI, Emulex LP1050−E16, 17, 18 FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−27.EL7 PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, DL58513, AX100
ML370(G3)13, ML370(G4)13;
IBM xSeries: x345 (8670), x445 (8870)
59 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI, Emulex LP982−E16, 17 FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−27.EL7 PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, AX100
ML370(G3)13, ML370(G4)13;
IBM xSeries: x345 (8670), x445 (8870)
60 Fujitsu Siemens Primergy BX300 Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI, Fujitsu Siemens FC−AL, EMC N1, 2
v2.4.21−27.EL7 PCI−X S26361−F2843−E1 (Emulex FC−SW CLARiiON
LP9802)16, 32, 61 AX100
61 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0 U4 AS/ES PCI, QLogic QLA2340−E−SP11, 12, 38 FC−AL, EMC N1, 2
v2.4.21−27.EL7 PCI−X FC−SW CLARiiON
AX100
62 HPQ Proliant: 850013, DL32013, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI Emulex LP1050−E16, 17, 18 FC−AL, EMC N1, 2
DL360(G2)13, DL36013, DL58013, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8 FC−SW CLARiiON
ML350(G2)13, ML350(G3)13, ML35013, AX100
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
63 Dell PowerEdge: 2600, 2650, 2850, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
4600, 6600, 6650; v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
v2.4.21−27.0.4.EL7, 8 AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries x365;
Samsung: SS370, SS3840
64 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X Emulex LP101−E16, 19, 20 FC−AL, EMC N1, 2
1800, 2800 v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
v2.4.21−27.0.4.EL7, 8 AX100
65 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X Emulex: LP1050−E16, 17, 18, FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL74013, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, LP982−E16, 17 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13; v2.4.21−27.0.4.EL7, 8 AX100
IBM xSeries x365
66 IBM xSeries x365 Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X QLogic QLA200−E−SP14, 38 FC−AL, EMC N1, 2
v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
v2.4.21−27.0.4.EL7, 8 AX100
67 Dell PowerEdge: 2600, 2650, 2850, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X QLogic QLA200−E−SP4, 14, 15 FC−AL, EMC N1, 2
4600, 6600, 6650; v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
v2.4.21−27.0.4.EL7, 8 AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL56013, DL74013, DL760 (G2)13,
DL76013, ML570(G2)13
68 Dell PowerEdge: 2600, 2650, 2850, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X QLogic QLA2340−E−SP11, 12 FC−AL, EMC N1, 2
4600, 6600, 6650; v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
v2.4.21−27.0.4.EL7, 8 AX100
Fujitsu Siemens Primergy: RX200 S2,
RX600 S2, TX600 S2
69 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI−X QLogic QLA2340−E−SP11, 12, 38 FC−AL, EMC N1, 2
RX600 S2, TX600 S2; v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
v2.4.21−27.0.4.EL7, 8 AX100
IBM xSeries: x346 (8840)46, x365
70 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI, Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−27.0.4.EL7, 8 AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13
71 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI Emulex LP101−E16, 19, 20 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 v2.4.21−27.0.4.EL7, 8; AX100
Red Hat RHEL [32−Bit] 3.0 U5 AS/ES:
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8;
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8

11/02/2006 82 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
72 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI Emulex: LP101−E16, 17, 19, FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, LP982−E16, 17; FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, v2.4.21−27.0.4.EL7, 8; AX100
ML37013, ML530(G2)13, ML530(G3)13, QLogic QLA200−E−SP4, 14, 15
ML53013, ML57013, ML75013 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES:
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8;
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
73 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI, Emulex LP1050−E16, 17, 18 FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, DL58513, v2.4.21−27.0.4.EL7, 8; AX100
ML370(G3)13, ML370(G4)13
Red Hat RHEL [32−Bit] 3.0 U5 AS/ES:
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8;
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
74 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI, Emulex LP982−E16, 17 FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−27.0.1.EL7, 8, v2.4.21−27.0.2.EL7, 8, PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, v2.4.21−27.0.4.EL7, 8; AX100
ML370(G3)13, ML370(G4)13
Red Hat RHEL [32−Bit] 3.0 U5 AS/ES:
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8;
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
75 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES: PCI QLogic QLE2360−E−SP36, 37, 38 FC−AL, EMC N1, 2
2850; v2.4.21−27.0.2.EL7, 8, v2.4.21−27.0.4.EL7, 8 Express FC−SW CLARiiON
AX100
IBM xSeries x346 (8840)46
76 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI Emulex: LP1050−E16, 27, 32, 43 , FC−AL, EMC Y
S2F34, S234 v2.4.21−32.EL7, 8 LP1050−E16, 27, 32, 53 ; FC−SW CLARiiON
AX100
Fujitsu Siemens BX600−FC22Q11,
27, 33

77 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI Fujitsu Siemens: BX600−FC22Q11, FC−AL, EMC N1, 2
S2F34, S234; v2.4.21−32.EL7, 8 27, 33, BX600−FC22Q11, 27, 33, 38 , FC−SW CLARiiON
BX600−FC22Q5, 11, 27, 33 AX100
Fujitsu Siemens Primergy BX62034
78 NEC Express 5800: 120Rd−1, 140Hd, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI NEC N8190−120: (LP1050)16, 19, FC−AL, EMC N1, 2
140Rc−4, 180Rd−4 v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; 35, 60, (LP1050)16, 19, 35, 61, 62 FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
79 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex LP1050Ex−E16, 19, 27, 44 ; FC−AL, EMC Y1, 2
2850, 6800, 6850; v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; Express QLogic QLE2360−E−SP27, 29, 36, FC−SW CLARiiON
37 AX100
Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
HR−6850; v2.4.21−32.0.1.EL7, 8
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
80 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E16, 17, 19, 27 , FC−AL, EMC Y1, 2
2850; v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; Express, LP1050−E16, 17, 18, 27 ; FC−SW CLARiiON
PCI−X AX100
LangChao: NC3000, NC3500, NF500, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA200−E−SP4, 14, 27, 38
NF520 v2.4.21−32.0.1.EL7, 8
81 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E16, 17, 19, FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; Express, LP1050−E16, 17, 18, LP982−E16, 17; FC−SW CLARiiON
PCI−X AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic: QLA200−E−SP14, 15,
v2.4.21−32.0.1.EL7, 8 QLA2340−E−SP11, 12, 15
82 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)13, AX100
DL360(G4)13, DL56013, DL74013, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
DL760 (G2)13, DL76013, ML570(G2)13 v2.4.21−32.0.1.EL7, 8
83 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex LP101−E16, 19, 20 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
84 Dell PowerEdge: 2600, 2650, 6800, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP101−E16, 17, 19, 27 , FC−AL, EMC Y1, 2
6850; v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; LP1050−E16, 17, 18, 27 ; FC−SW CLARiiON
AX100
Digital Henge SH4500R4; Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA200−E−SP4, 14, 27, 38
IBM xSeries: x336 (8837)46, x346 v2.4.21−32.0.1.EL7, 8
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS370, SS3840, ZSS150,
ZSS230

11/02/2006 83 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
85 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP1050−E16, 17, 18, FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL74013, v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; LP982−E16, 17; FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13 AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA2340−E−SP11, 12, 15
v2.4.21−32.0.1.EL7, 8
86 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP1050−E16, 18, 20, FC−AL, EMC N1, 2
4600, 6600, 6650 v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; LP982−E16, 20 FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
87 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X QLogic QLA200−E−SP4, 14, 15 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)13, AX100
DL56013, DL74013, DL760 (G2)13, Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
DL76013, ML570(G2)13 v2.4.21−32.0.1.EL7, 8
88 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X QLogic QLA2340−E−SP11, 12 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; FC−SW CLARiiON
IBM xSeries: x255, x365, x440 AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
89 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X83 Emulex: LP101−E16, 17, 19, 27 , FC−AL, EMC Y1, 2
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; LP1050−E16, 17, 18, 27 ; FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA200−E−SP4, 14, 27, 38
v2.4.21−32.0.1.EL7, 8
90 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex LP101−E16, 17, 19 FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; PCI−X FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
91 HPQ Proliant DL38513 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex LP1050−E16, 18, 20 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; PCI−X FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
92 Samsung: ES470, ES570, SS140 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex: LP101−E16, 17, 19, 27 , FC−AL, EMC Y1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; PCI−X LP1050−E16, 17, 18, 27 ; FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLogic QLA200−E−SP4, 14, 27, 38
v2.4.21−32.0.1.EL7, 8
93 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, QLogic QLA200−E−SP4, 14, 15 FC−AL, EMC N1, 2
DL380(G3)13, DL38013, DL38513, v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, DL58513, AX100
ML370(G3)13 Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
94 IBM xSeries x445 (8870) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, QLogic QLA2340−E−SP11, 12 FC−AL, EMC N1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; PCI−X FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
95 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E16, 19, 31, FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−40.EL7, 25 LP1050−E16, 18, 31, LP982−E16, 31 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
96 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Fujitsu Siemens BX600−FC22Q11, FC−AL, EMC Y
S2F34, S234 v2.4.21−40.EL7, 25 27, 29, 33 FC−SW CLARiiON
AX100
97 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL36013, DL58013, ML350(G2)13, v2.4.21−40.EL7, 25 27, 28, 31 ; FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, QLogic: QLA200−E−SP14, 29, AX100
ML37013, ML530(G2)13, ML530(G3)13, QLA210−E−SP14, 27, 29,
ML53013, ML57013, ML75013 QLA2340−E−SP11, 29,
QLE220−E−SP27, 93, 94, 108
98 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.4.21−40.EL7, 25 31, 35 FC−SW CLARiiON
AX100
99 Unisys: ES3120, ES3120L, ES3140, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLA2340−E−SP11, 27, 29 FC−AL, EMC Y
ES3140L v2.4.21−40.EL7, 25 FC−SW CLARiiON
AX100
100 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 31 ; FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−40.EL7, 25 Express QLogic QLE2360−E−SP27, 29, 36, FC−SW CLARiiON
37 AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 84 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
101 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LPe111−E16, 27, 31, 54 , FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−40.EL7, 25 Express LPe1150−E16, 27, 31, 42 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
102 HPQ Proliant: DL360(G4)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y
DL380(G4)13, DL580(G3)13, v2.4.21−40.EL7, 25 Express (LPe1150)16, 27, 31, 68 , FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 AD167A/FC2143 (LP1150)16, 27, 28, AX100
31

103 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLE2460−E−SP27, 29, 56 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−40.EL7, 25 Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
104 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E16, 19, 27, 31 , FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, LP1050−E16, 18, 27, 31 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X LP1050Ex−E16, 19, 27, 31 , AX100
AS2500; LP982−E16, 27, 31, LPe111−E16, 27,
31, 54, LPe1150−E16, 27, 31, 42 ;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL QLogic: QLA200−E−SP14, 27, 30,
QLA2340−E−SP11, 27, 29,
QLE2360−E−SP27, 29, 36, 37 ,
QLE2460−E−SP27, 29, 56
105 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E16, 19, 31, FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, LP1050−E16, 18, 31, LP982−E16, 31; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 29, 111 ,
AD167A/FC2143 (LP1150)16, 27, 28,
31, AE369A/FC1243 (QLA2462)27,
29, 111;

QLogic: QLA200−E−SP14, 29,


QLA2340−E−SP11, 29,
QLE220−E−SP27, 93, 94, 108
106 IBM xSeries: x3550 (7978), x3650 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP1050−E16, 18, 27, 31 , FC−AL, EMC Y96
(7979) v2.4.21−40.EL7, 25 Express, LP1050Ex−E16, 19, 27, 31 ; FC−SW CLARiiON
PCI−X AX100
IBM: 24P0960 (QLA2340)11, 27, 29,
66, 24P8053 (QLA2342)11, 27, 29 ,
39M5894 (QLA2460)27, 29, 56,
39M5895 (QLA2462)27, 29, 56;
QLogic: QLA2340−E−SP11, 27, 29,
QLA2460−E−SP27, 29, 56,
QLE2360−E−SP27, 29, 37,
QLE2460−E−SP27, 29, 56
107 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX100
AS2500;
HPQ Proliant ML350(G4)13;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
108 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Dell 2342M11, 29 FC−AL, EMC Y
Unisys ES3105 v2.4.21−40.EL7, 25 FC−SW CLARiiON
AX100
109 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Dell: LPe1105−M16, 27, 31, 42 , FC−AL, EMC Y
v2.4.21−40.EL7, 25 QME246227, 29, 41 FC−SW CLARiiON
AX100
110 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex LP1050−E16, 27, 31, 32 FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 S2 v2.4.21−40.EL7, 25 FC−SW CLARiiON
AX100
111 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex LP982−E16, 27, 31 FC−AL, EMC Y
2650, 2850, 6800, 6850; v2.4.21−40.EL7, 25 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230

11/02/2006 85 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
112 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex: LP101−E16, 19, 27, 31 , FC−AL, EMC Y
2600, 2650, 2850, 6800, 6850; v2.4.21−40.EL7, 25 LP1050−E16, 18, 27, 31 ; FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, QLogic: QLA200−E−SP14, 27, 30,
HR−6850; QLA2340−E−SP11, 27, 29
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
113 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex: LP101−E16, 19, 31, FC−AL, EMC Y
4600, 6600, 6650; v2.4.21−40.EL7, 25 LP1050−E16, 18, 31, LP982−E16, 31 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
114 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL360(G4)13, DL56013, DL74013, v2.4.21−40.EL7, 25 27, 28, 31 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13 AX100
115 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(416654−B21), (416655−B21), v2.4.21−40.EL7, 25 HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403621−B21)31, 54, 72 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
116 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(416654−B21), (416655−B21), v2.4.21−40.EL7, 25 HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403619−B21)29, 69 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
117 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.4.21−40.EL7, 25 (QLA2460)27, 29, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 29, AX100
111

118 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ: Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−40.EL7, 25 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 29, AX100
Emulex−based BL25/30/35/45p
Fibre Channel Mezzanine HBA −
394588−B2116, 22, 23, 31
119 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−40.EL7, 25 31, 35 FC−SW CLARiiON
140Rd−4 AX100
120 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 31, FC−AL, EMC Y
v2.4.21−40.EL7, 25 35, 68 FC−SW CLARiiON
AX100
121 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y
2650, 2850, 4600, 6600, 6650, 6800, v2.4.21−40.EL7, 25 FC−SW CLARiiON
6850; AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
122 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic QLE220−E−SP27, 93, 94, 108 FC−AL, EMC Y
HR−6850; v2.4.21−40.EL7, 25 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230

11/02/2006 86 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
123 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic: QLA200−E−SP14, 29, FC−AL, EMC Y
v2.4.21−40.EL7, 25 QLA2340−E−SP11, 29 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)13, AX100
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
124 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X67 Emulex: LP101−E16, 19, 27, 31 , FC−AL, EMC Y
v2.4.21−40.EL7, 25 LP1050−E16, 18, 27, 31 , LP982−E16, FC−SW CLARiiON
27, 31; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 27, 29,
QLE220−E−SP27, 93, 94, 108
125 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y
v2.4.21−40.EL7, 25 Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394757−B2116, 22, 23, 31 AX100
126 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y
v2.4.21−40.EL7, 25 BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
22, 23, 31

127 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X83 QLogic: QLA210−E−SP14, 27, 29, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−40.EL7, 25 QLE220−E−SP27, 93, 94, 108 FC−SW CLARiiON
AX100
128 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 31, 42 , FC−AL, EMC Y
v2.4.21−40.EL7, 25 Express, QME246227, 29, 41 FC−SW CLARiiON
PCI−X AX100
129 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex LP982−E16, 31 FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, AX100
ML370(G3)13, ML370(G4)13
130 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E16, 19, 27, 31 , FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−40.EL7, 25 PCI−X LP1050−E16, 18, 27, 31 , LP982−E16, FC−SW CLARiiON
27, 31; AX100
QLogic QLA200−E−SP14, 27, 30
131 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E16, 19, 31, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−40.EL7, 25 PCI−X LP1050−E16, 18, 31; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 HPQ AD167A/FC2143 (LP1150)16,
27, 28, 31 ;
QLogic QLA200−E−SP14, 29
132 HPQ Proliant: DL380(G4)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
ML370(G4)13 v2.4.21−40.EL7, 25 PCI−X (QLA2460)27, 29, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 29, AX100
111

133 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
134 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 29 FC−AL, EMC Y
Fujitsu Siemens Primergy RX800 S2; v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 AX100
135 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 30 FC−AL, EMC Y
Samsung ES470 v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
AX100
136 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP11, 29 FC−AL, EMC Y
HPQ Proliant: DL380(G2)13, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL580(G2)13, DL580(G3)13,
ML370(G3)13, ML370(G4)13
137 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLE220−E−SP27, 93, 94, 108 FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−40.EL7, 25 PCI−X FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
138 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−47.EL7, 25 LP1050−E16, 18, 26, LP982−E16, 26 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
139 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL36013, DL58013, ML350(G2)13, v2.4.21−47.EL7, 25 26, 27, 28 ; FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, QLogic: QLA200−E−SP14, 24, AX100
ML37013, ML530(G2)13, ML530(G3)13, QLA210−E−SP14, 24, 27,
ML53013, ML57013, ML75013 QLA2340−E−SP11, 24,
QLE220−E−SP27, 93, 94
140 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.4.21−47.EL7, 25 26, 35 FC−SW CLARiiON
AX100

11/02/2006 87 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
141 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex LP1050Ex−E16, 19, 26, 27 ; FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−47.EL7, 25 Express QLogic QLE2360−E−SP24, 27, 36, FC−SW CLARiiON
37 AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
142 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LPe111−E16, 26, 27, 54 , FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−47.EL7, 25 Express LPe1150−E16, 26, 27, 42 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
143 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(403434−B21), (407234−B21), v2.4.21−47.EL7, 25 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)26, 54, 72 AX100
144 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(403434−B21), (407234−B21), v2.4.21−47.EL7, 25 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403619−B21)24, 69 AX100
145 HPQ Proliant: DL360(G4)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y
DL380(G4)13, DL580(G3)13, v2.4.21−47.EL7, 25 Express (LPe1150)16, 26, 27, 68 , FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 AD167A/FC2143 (LP1150)16, 26, 27, AX100
28

146 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic QLE2460−E−SP24, 27, 56 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.4.21−47.EL7, 25 Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
147 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E16, 19, 26, 27 , FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, LP1050−E16, 18, 26, 27 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X LP1050Ex−E16, 19, 26, 27 , AX100
AS2500; LP982−E16, 26, 27, LPe111−E16, 26,
27, 54, LPe1150−E16, 26, 27, 42 ;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL QLogic: QLA200−E−SP14, 24, 27,
QLA2340−E−SP11, 24, 27,
QLE2360−E−SP24, 27, 36, 37 ,
QLE2460−E−SP24, 27, 56
148 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, LP1050−E16, 18, 26, LP982−E16, 26; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)24, 27, 111 ,
AD167A/FC2143 (LP1150)16, 26, 27,
28, AE369A/FC1243 (QLA2462)24,
27, 111;

QLogic: QLA200−E−SP14, 24,


QLA2340−E−SP11, 24,
QLE220−E−SP27, 93, 94
149 IBM xSeries: x3550 (7978), x3650 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP1050−E16, 18, 26, 27 , FC−AL, EMC Y96
(7979), x3755 (8877) v2.4.21−47.EL7, 25 Express, LP1050Ex−E16, 19, 26, 27 ; FC−SW CLARiiON
PCI−X AX100
IBM: 24P0960 (QLA2340)11, 24, 27,
66, 24P8053 (QLA2342)11, 24, 27 ,
39M5894 (QLA2460)24, 27, 56,
39M5895 (QLA2462)24, 27, 56;
QLogic: QLA2340−E−SP11, 24, 27,
QLA2460−E−SP24, 27, 56,
QLE2360−E−SP24, 27, 37,
QLE2460−E−SP24, 27, 56
150 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI NEC: N8190−120 (LP1050)18, 26, FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.4.21−47.EL7, 25 Express, 35, 116, N8190−127 (LPe1150)26, FC−SW CLARiiON
PCI−X 35, 42, 116 AX100
151 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic QLA210−E−SP14, 24, 27 FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX100
AS2500;
HPQ Proliant ML350(G4)13;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 88 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
152 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Dell 2342M11, 24 FC−AL, EMC Y
Unisys ES3105 v2.4.21−47.EL7, 25 FC−SW CLARiiON
AX100
153 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Dell: LPe1105−M16, 26, 27, 42 , FC−AL, EMC Y
v2.4.21−47.EL7, 25 QME246224, 27, 41 FC−SW CLARiiON
AX100
154 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Emulex LP982−E16, 26, 27 FC−AL, EMC Y
2650, 2850, 6800, 6850; v2.4.21−47.EL7, 25 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
155 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Emulex: LP101−E16, 19, 26, 27 , FC−AL, EMC Y
2600, 2650, 2850, 6800, 6850; v2.4.21−47.EL7, 25 LP1050−E16, 18, 26, 27 ; FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, QLogic: QLA200−E−SP14, 24, 27,
HR−6850; QLA2340−E−SP11, 24, 27
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
156 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
4600, 6600, 6650; v2.4.21−47.EL7, 25 LP1050−E16, 18, 26, LP982−E16, 26 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
157 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL360(G4)13, DL56013, DL74013, v2.4.21−47.EL7, 25 26, 27, 28 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13 AX100
158 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(416654−B21), (416655−B21), v2.4.21−47.EL7, 25 HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403621−B21)26, 54, 72 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
159 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(416654−B21), (416655−B21), v2.4.21−47.EL7, 25 HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403619−B21)24, 69 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
160 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.4.21−47.EL7, 25 (QLA2460)24, 27, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)24, 27, AX100
111

161 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ: Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−47.EL7, 25 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 24, AX100
Emulex−based BL25/30/35/45p
Fibre Channel Mezzanine HBA −
394588−B2116, 22, 23, 26
162 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−47.EL7, 25 26, 35 FC−SW CLARiiON
140Rd−4 AX100
163 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 26, FC−AL, EMC Y
v2.4.21−47.EL7, 25 35, 68 FC−SW CLARiiON
AX100

11/02/2006 89 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
164 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X QLogic QLA210−E−SP14, 24, 27 FC−AL, EMC Y
2650, 2850, 4600, 6600, 6650, 6800, v2.4.21−47.EL7, 25 FC−SW CLARiiON
6850; AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
165 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X QLogic QLE220−E−SP27, 93, 94 FC−AL, EMC Y
HR−6850; v2.4.21−47.EL7, 25 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
166 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X QLogic: QLA200−E−SP14, 24, FC−AL, EMC Y
v2.4.21−47.EL7, 25 QLA2340−E−SP11, 24 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)13, AX100
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
167 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X67 Emulex: LP101−E16, 19, 26, 27 , FC−AL, EMC Y
v2.4.21−47.EL7, 25 LP1050−E16, 18, 26, 27 , LP982−E16, FC−SW CLARiiON
26, 27; AX100
QLogic: QLA200−E−SP14, 24, 27,
QLA210−E−SP14, 24, 27,
QLA2340−E−SP11, 24, 27,
QLE220−E−SP27, 93, 94
168 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−47.EL7, 25 Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 24 AX100
169 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y
v2.4.21−47.EL7, 25 Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394757−B2116, 22, 23, 26 AX100
170 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y
v2.4.21−47.EL7, 25 BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
22, 23, 26

171 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X83 QLogic: QLA210−E−SP14, 24, 27, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−47.EL7, 25 QLE220−E−SP27, 93, 94 FC−SW CLARiiON
AX100
172 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Dell: LPe1105−M16, 26, 27, 42 , FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, QME246224, 27, 41 FC−SW CLARiiON
PCI−X AX100
173 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, LP1050−E16, 18, 26, LP982−E16, 26, FC−SW CLARiiON
PCI−X LPe111−E 16, 26, 27, 54 , AX100
LPe1150−E16, 26, 27, 42 ;
HPQ: A8002A/FC2142SR
(LPe1150)16, 26, 27, 68 ,
AD167A/FC2143 (LP1150)16, 26, 27,
28, AE311A/FC1142SR
(QLE2460)24, 27, 56,
AE312A/FC1242SR (QLE2462)24,
27, 56;

QLogic: QLA200−E−SP14, 24,


QLA210−E−SP14, 24, 27,
QLA2340−E−SP11, 24,
QLE220−E−SP27, 93, 94
174 HPQ Proliant DL380(G5) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.4.21−47.EL7, 25 Express, (QLA2460)24, 27, 111 , FC−SW CLARiiON
PCI−X AE369A/FC1243 (QLA2462)24, 27, AX100
111

11/02/2006 90 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
175 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex LP982−E16, 26; FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−47.EL7, 25 PCI−X QLogic QLA2340−E−SP11, 24 FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, AX100
ML370(G3)13, ML370(G4)13
176 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex: LP101−E16, 19, 26, 27 , FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−47.EL7, 25 PCI−X LP1050−E16, 18, 26, 27 , LP982−E16, FC−SW CLARiiON
26, 27; AX100
QLogic: QLA200−E−SP14, 24, 27,
QLA2340−E−SP11, 24, 27
177 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex: LP101−E16, 19, 26, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−47.EL7, 25 PCI−X LP1050−E16, 18, 26; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 HPQ AD167A/FC2143 (LP1150)16,
26, 27, 28 ;
QLogic QLA200−E−SP14, 24
178 HPQ Proliant: DL380(G4)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
ML370(G4)13 v2.4.21−47.EL7, 25 PCI−X (QLA2460)24, 27, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)24, 27, AX100
111

179 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, QLogic QLA210−E−SP14, 24, 27 FC−AL, EMC Y
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−47.EL7, 25 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL38513, DL580(G2)13, DL580(G3)13,
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
180 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, QLogic QLE220−E−SP27, 93, 94 FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−47.EL7, 25 PCI−X FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung: ES470, ES570, SS140
181 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP101−E16, 19, 60; FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, QLogic QLA2340−E−SP11, 38, 65 FC−SW CLARiiON
x350 (6000R), x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
182 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP1050−E16, 18, 62 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
HPQ Proliant: 850013, DL32013,
DL360(G2)13, DL36013, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
183 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex: LP101−E16, 19, 62, FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, LP982−E16, 62 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
184 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 62 ; FC−AL, EMC N1, 2
2850 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, Express QLogic QLE2360−E−SP15, 36, 37 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
185 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Dell 2342M11 FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
186 IBM xSeries: x235, x255, x360, x365, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Emulex LP101−E16, 19, 60; FC−AL, EMC N1, 2
x440 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, QLogic QLA2340−E−SP11, 38, 65 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
187 HPQ Proliant BL40p Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 15, 65 FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
188 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, Emulex LP101−E16, 19, 60; FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, PCI−X QLogic QLA2340−E−SP11, 38, 65 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
189 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, Emulex LP982−E16, 62; FC−AL, EMC N1, 2
HPQ Proliant: DL380(G2)13, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, PCI−X QLogic QLA2340−E−SP11, 15 FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
DL580(G2)13, DL580(G3)13, v2.4.21−15.0.4.EL7
ML370(G3)13
190 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP1050−E16, 18, 60 FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
x350 (6000R), x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7
191 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Emulex LP982−E16, 60 FC−AL, EMC N1, 2
x250, x330, x335, x342, x350 (6000R), v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7
192 IBM xSeries: x235, x255, x360, x365, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Emulex: LP1050−E16, 18, 60, FC−AL, EMC N1, 2
x440 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, LP982−E16, 60 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7

11/02/2006 91 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
193 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, Emulex: LP1050−E16, 18, 60, FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, PCI−X LP982−E16, 60 FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7
194 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI QLogic QLA200−E−SP14, 38 FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
x350 (6000R), x370 U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7,
U4 AS/ES v2.4.21−27.EL7
195 IBM xSeries: x235, x255, x360, x365, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X QLogic QLA200−E−SP14, 38 FC−AL, EMC N1, 2
x440 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U3 AS/ES v2.4.21−20.EL7,
U4 AS/ES v2.4.21−27.EL7
196 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Emulex LP101−E16, 32, 61 FC−AL, EMC N1, 2
RX300 S2, TX200 S2, TX300 S2 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U4 AS/ES v2.4.21−27.EL7
197 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, QLogic QLA200−E−SP14, 38 FC−AL, EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, PCI−X FC−SW CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7, U4 AS/ES v2.4.21−27.EL7
198 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI Fujitsu Siemens BX600−FC22Q11, FC−AL, EMC N1, 2
S2F34, S234; v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7 27, 33, 65, 117 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: BX62034,
BX66034
199 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI QLogic QLA2340−E−SP11, 15 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
200 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Emulex: LP101−E16, 19, 62, FC−AL, EMC N1, 2
1800, 2600, 2650, 2800, 2850, 4600, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7 LP1050−E16, 18, 62, LP982−E16, 62 FC−SW CLARiiON
6600, 6650; AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
Samsung: SS370, SS3840
201 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 15 FC−AL, EMC N1, 2
2600, 2650, 2850, 4600, 6600, 6650; v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
Samsung: SS370, SS3840
202 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI QLogic QLA200−E−SP14 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; U3 AS/ES v2.4.21−20.EL7 AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
203 Fujitsu Siemens Primergy: RX200, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X Fujitsu Siemens FC−AL, EMC N1, 2
RX200 S2, RX300, RX300 S2, TX200, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, S26361−F2843−E1 (Emulex FC−SW CLARiiON
TX200 S2, TX300, TX300 S2 U3 AS/ES v2.4.21−20.EL7 LP9802)16, 32, 61 AX100
204 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X QLogic QLA200−E−SP14 FC−AL, EMC N1, 2
2600, 2650, 2850, 4600, 6600, 6650; v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, FC−SW CLARiiON
U3 AS/ES v2.4.21−20.EL7 AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL56013, DL74013, DL760 (G2)13,
DL76013, ML570(G2)13
205 Fujitsu Siemens Primergy: BX300, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, Fujitsu Siemens FC−AL, EMC N1, 2
RX600, RX800, TX600 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, PCI−X S26361−F2843−E1 (Emulex FC−SW CLARiiON
U3 AS/ES v2.4.21−20.EL7 LP9802)16, 32, 61 AX100
206 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI, QLogic QLA200−E−SP14 FC−AL, EMC N1, 2
HPQ Proliant: DL380(G2)13, v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, PCI−X FC−SW CLARiiON
DL380(G3)13, DL38013, DL580(G2)13, U3 AS/ES v2.4.21−20.EL7 AX100
DL580(G3)13, ML370(G3)13
207 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
140Hd, 140Rc−4, 180Rd−4 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, 35, 61, 62 FC−SW CLARiiON
U4 AS/ES v2.4.21−27.EL7, U4+ AS/ES AX100
v2.4.21−27.0.1.EL7, 8, U4+ AS/ES
v2.4.21−27.0.2.EL7, 8, U4+ AS/ES
v2.4.21−27.0.4.EL7, 8
208 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7, 35, 61, 62 FC−SW CLARiiON
U4 AS/ES v2.4.21−27.EL7, U4+ AS/ES AX100
v2.4.21−27.0.1.EL7, 8, U4+ AS/ES
v2.4.21−27.0.2.EL7, 8, U4+ AS/ES
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8

11/02/2006 92 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
209 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI QLogic QLA2340−E−SP11 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
210 IBM xSeries: x225, x230, x232, x240, Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI QLogic QLA2340−E−SP11, 38 FC−AL, EMC N1, 2
x250, x330, x335, x340 (4500R), x342, v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 FC−SW CLARiiON
x350 (6000R), x370 AX100
211 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI QLogic QLA2340−E−SP11 FC−AL, EMC N1, 2
v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 Express, FC−SW CLARiiON
PCI−X AX100
212 IBM xSeries x336 (8837)46 Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI QLogic QLA2340−E−SP11, 38 FC−AL, EMC N1, 2
v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 Express, FC−SW CLARiiON
PCI−X AX100
213 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI QLogic QLA2340−E−SP11 FC−AL, EMC N1, 2
v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 Express, FC−SW CLARiiON
PCI−X 67 AX100
214 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP11 FC−AL, EMC N1, 2
2600, 2650, 2850, 4600, 6600, 6650; v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
Samsung: SS370, SS3840
215 IBM xSeries: x235, x255, x346 Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP11, 38 FC−AL, EMC N1, 2
(8840)46, x360, x365, x440 v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 FC−SW CLARiiON
AX100
216 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI, QLogic QLA2340−E−SP11 FC−AL, EMC N1, 2
HPQ Proliant: DL380(G2)13, v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 PCI−X FC−SW CLARiiON
DL380(G3)13, DL380(G4)13, DL38013, AX100
DL580(G2)13, DL580(G3)13,
ML370(G3)13, ML370(G4)13
217 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI, QLogic QLA2340−E−SP11, 38 FC−AL, EMC N1, 2
v2.4.21−20.EL6, 7, U5 AS/ES v2.4.21−32.EL6, 7, 8 PCI−X FC−SW CLARiiON
AX100
218 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI QLogic QLE2360−E−SP36, 37, 38 FC−AL, EMC N1, 2
2850; v2.4.21−20.EL7, U4 AS/ES v2.4.21−27.EL7, U4+ Express FC−SW CLARiiON
AS/ES v2.4.21−27.0.1.EL7, 8 AX100
IBM xSeries: x336 (8837)46, x346
(8840)46
219 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
140Hd, 140Rc−4, 180Rd−4 v2.4.21−20.EL7, U4 AS/ES v2.4.21−27.EL7, U4+ 35, 60 FC−SW CLARiiON
AS/ES v2.4.21−27.0.1.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.2.EL7, 8, U4+ AS/ES
v2.4.21−27.0.4.EL7, 8
220 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI−X Dell 2342M11, 38 FC−AL, EMC N1, 2
v2.4.21−20.EL7, U4 AS/ES v2.4.21−27.EL7, U4+ FC−SW CLARiiON
AS/ES v2.4.21−27.0.1.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.2.EL7, 8, U4+ AS/ES
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
221 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0: U3 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−20.EL7, U4 AS/ES v2.4.21−27.EL7, U4+ 35, 60 FC−SW CLARiiON
AS/ES v2.4.21−27.0.1.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.2.EL7, 8, U4+ AS/ES
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
222 IBM xSeries x336 (8837)46 Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI QLogic QLA2340−E−SP11, 12, 38 FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8 Express, FC−SW CLARiiON
PCI−X AX100
223 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI Emulex LP1050Ex−E16, 17, 19, 27 FC−AL, EMC N1, 2
2850 v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Express FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
224 Dell PowerEdge: 6800, 6850 Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI QLogic QLE2360−E−SP15, 27, 36, FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Express 37 FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
225 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI Emulex: LP101−E16, 17, 19, FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Express, LP1050−E16, 17, 18, LP982−E16, 17; FC−SW CLARiiON
HPQ Proliant ML350(G4)13 U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES PCI−X AX100
v2.4.21−27.0.4.EL7, 8 QLogic: QLA200−E−SP14, 15,
QLA2340−E−SP11, 12, 15
226 NEC Express 5800 110Rg−1 Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Express, 20, 35 FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES PCI−X AX100
v2.4.21−27.0.4.EL7, 8
227 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI Emulex: LP101−E16, 17, 19, FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Express, LP1050−E16, 17, 18, LP982−E16, 17; FC−SW CLARiiON
7, 8
U4+ AS/ES v2.4.21−27.0.2.EL , U4+ AS/ES PCI−X 67 AX100
v2.4.21−27.0.4.EL7, 8 QLogic: QLA200−E−SP14, 15,
QLA2340−E−SP11, 12, 15

11/02/2006 93 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
228 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X Emulex LP1050Ex−E16, 27, 32, 60 FC−AL, EMC N1, 2
RX600 S2, TX600 S2 v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
229 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X Emulex: LP1050−E16, 18, 20, FC−AL, EMC N1, 2
1800, 2600, 2650, 2800, 2850, 4600, v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, LP982−E16, 20 FC−SW CLARiiON
6600, 6650; 7, 8
U4+ AS/ES v2.4.21−27.0.2.EL , U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
Samsung: SS370, SS3840
230 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X QLogic QLA2340−E−SP11, 12, 15 FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL74013, v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13; U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
Samsung: SS370, SS3840
231 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI, Emulex LP1050−E16, 18, 20 FC−AL, EMC N1, 2
HPQ Proliant DL38513 v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, PCI−X FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
232 Dell PowerEdge 1850 Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI, Emulex LP982−E16, 20; FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, PCI−X QLogic QLA2340−E−SP11, 12 FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
233 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI, QLogic QLA200−E−SP4, 14, 15 FC−AL, EMC N1, 2
HPQ Proliant: DL14513, DL380(G2)13, v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, PCI−X FC−SW CLARiiON
DL380(G3)13, DL38013, DL38513, U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
DL580(G2)13, DL580(G3)13, DL58513, v2.4.21−27.0.4.EL7, 8
ML370(G3)13
234 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI Emulex: LP1050−E16, 18, 20, FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, LP982−E16, 20 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
235 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI QLogic QLA2340−E−SP11, 12, 15 FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
ML37013, ML530(G2)13, ML530(G3)13, v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
ML53013, ML57013, ML75013 7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
236 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X HPQ Dual−port Fibre Channel FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Adapter for HP Proliant FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES BL25p/BL45p 381881−B213, 4, 5 AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
237 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X QLogic QLA200−E−SP14, 15 FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
238 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL, EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, Adapter for HP Proliant FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES BL25p/BL45p 381881−B213, 4, 5 AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
239 HPQ Proliant: DL380(G4)13, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI, QLogic QLA200−E−SP14, 15 FC−AL, EMC N1, 2
ML370(G4)13 v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, PCI−X FC−SW CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
240 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI, QLogic QLA2340−E−SP11, 12, 15 FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, PCI−X FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
ML370(G3)13, ML370(G4)13 v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6,
7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
241 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0: U4+ AS/ES PCI Emulex LP1050−E16, 17, 18 FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.4.21−27.0.4.EL7, 8, U5 AS/ES v2.4.21−32.EL6, FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, 7, 8, U5 AS/ES v2.4.21−32.EL7, 8, U5+ AS/ES AX100
ML37013, ML530(G2)13, ML530(G3)13, v2.4.21−32.0.1.EL7, 8
ML53013, ML57013, ML75013
242 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E16, 19, 44, FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 44, LP982−E16, 44 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL58013, ML350(G2)13,
ML350(G3)13, ML35013, ML370(G2)13,
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
243 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Fujitsu Siemens BX600−FC22Q11, FC−AL, EMC N1, 2
S2F34, S234 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 27, 29, 33 FC−SW CLARiiON
AX100
244 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL36013, DL58013, ML350(G2)13, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 27, 28, 44 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013

11/02/2006 94 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
245 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
140Hd, 140Rc−4, 180Rd−4 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 35, 79 FC−SW CLARiiON
AX100
246 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI QLogic: QLA200−E−SP14, 29, FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL QLA210−E−SP14, 27, 29, FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, QLA2340−E−SP11, 29 AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
247 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 44 ; FC−AL, EMC Y1, 2
2800, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express QLogic QLE2360−E−SP27, 29, 36, FC−SW CLARiiON
37 AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
248 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LPe111−E16, 27, 44, 54 , FC−AL, EMC Y1, 2
2800, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express LPe1150−E16, 27, 42, 44 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
249 HPQ Proliant: DL360(G4)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y1, 2
DL380(G4)13, DL580(G3)13, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express (LPe1150)16, 27, 44, 68 , FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 AD167A/FC2143 (LP1150)16, 27, 28, AX100
44

250 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI QLogic QLE2460−E−SP27, 29, 56 FC−AL, EMC Y1, 2
2800, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
251 Dell PowerEdge: 2900, 2950 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
PCI−X 27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 27, 29
252 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E16, 19, 44, FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, LP1050−E16, 18, 44, LP982−E16, 44; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 29, 111 ,
AE369A/FC1243 (QLA2462)27, 29,
111;

QLogic: QLA200−E−SP14, 29,


QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 29
253 Dell PowerEdge: 2900, 2950; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP1050Ex−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, LPe111−E16, 27, 44, 54 , FC−SW CLARiiON
IBM eServer 326m (Model 7969) PCI−X LPe1150−E16, 27, 42, 44 ; AX100
QLogic: QLE2360−E−SP27, 29, 36,
37, QLE2460−E−SP27, 29, 56

254 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, 27, 28, 44 FC−SW CLARiiON
PCI−X AX100
255 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Dell 2342M11, 29 FC−AL, EMC N1, 2
Unisys ES3105 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
256 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Dell: LPe1105−M16, 27, 42, 44 , FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL QME246227, 29, 41 FC−SW CLARiiON
AX100
257 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex LP1050−E16, 27, 32, 44 FC−AL, EMC Y1, 2
RX300 S2, TX200 S2, TX300 S2 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100

11/02/2006 95 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
258 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex LP982−E16, 27, 44 FC−AL, EMC Y1, 2
2650, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
259 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
2600, 2650, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 27, 44 ; FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, QLogic: QLA200−E−SP14, 27, 30,
HR−6850; QLA2340−E−SP11, 27, 29
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
260 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex: LP101−E16, 19, 44, FC−AL, EMC N1, 2
4600, 6600, 6650; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 44, LP982−E16, 44 FC−SW CLARiiON
AX100
HPQ Proliant: DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
261 HPQ Proliant BL40p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex: LP101−E16, 19, 44, FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 44, LP982−E16, 44; FC−SW CLARiiON
AX100
HPQ AD167A/FC2143 (LP1150)16,
27, 28, 44 ;
QLogic: QLA200−E−SP14, 29,
QLA2340−E−SP11, 29
262 HPQ Proliant: DL360(G3)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL360(G4)13, DL56013, DL74013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 27, 28, 44 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13 AX100
263 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (QLA2460)27, 29, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 29, AX100
111

264 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X HPQ: Dual−port Fibre Channel FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Adapter for HP Proliant FC−SW CLARiiON
BL25p/BL45p 381881−B213, 29, AX100
Emulex−based BL25/30/35/45p
Fibre Channel Mezzanine HBA −
394588−B2116, 22, 23, 44
265 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 35, 79 FC−SW CLARiiON
AX100
266 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC: N8190−120 (LP1050)16, 19, FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 35, 44, N8190−127 (LPe1150)16, 35, FC−SW CLARiiON
44, 68 AX100
267 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 29 FC−AL, EMC Y1, 2
2650, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant BL40p;
IBM xSeries: x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, ZSS150,
ZSS230
268 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic: QLA200−E−SP14, 29, FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL QLA210−E−SP14, 27, 29, FC−SW CLARiiON
HPQ Proliant: DL360(G3)13, QLA2340−E−SP11, 29 AX100
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13

11/02/2006 96 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
269 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X67 Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 27, 29
270 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394757−B2116, 22, 23, 44 AX100
271 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
22, 23, 44

272 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X83 Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
x3950/x3950E/x460 (8872, 8874)81, 82 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29,
QLA2340−E−SP11, 27, 29
273 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 42, 44 , FC−AL, EMC N1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, QME246227, 29, 41 FC−SW CLARiiON
PCI−X AX100
274 HPQ Proliant: DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex LP982−E16, 44; FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X QLogic QLA2340−E−SP11, 29 FC−SW CLARiiON
DL580(G2)13, DL580(G3)13, AX100
ML370(G3)13, ML370(G4)13
275 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex: LP101−E16, 19, 27, 44 , FC−AL, EMC Y1, 2
Samsung: ES470, ES570, SS140 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X LP1050−E16, 18, 27, 44 , LP982−E16, FC−SW CLARiiON
27, 44; AX100
QLogic: QLA200−E−SP14, 27, 30,
QLA210−E−SP14, 27, 29
276 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex: LP101−E16, 19, 44, FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X LP1050−E16, 18, 44; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 QLogic: QLA200−E−SP14, 29,
QLA210−E−SP14, 27, 29
277 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X 27, 28, 44 FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13
278 HPQ Proliant: DL380(G4)13, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC N1, 2
ML370(G4)13 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X (QLA2460)27, 29, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 29, AX100
111

279 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 29 FC−AL, EMC Y1, 2
Fujitsu Siemens Primergy RX800 S2; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 AX100
280 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 30 FC−AL, EMC Y1, 2
Samsung ES470 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
281 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP11, 29 FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
282 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X9 HPQ Dual−port Fibre Channel FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 Adapter for HP Proliant FC−SW CLARiiON
AS/ES v2.4.21−40.EL7, 25 BL25p/BL45p 381881−B213, 29 AX100
283 Dell PowerEdge 1950 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP27, 85, 103 FC−AL, EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 Express FC−SW CLARiiON
AX100
284 Dell PowerEdge: 1850, 1900, 2850, Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP27, 85, 103 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
285 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP27, 85, 103 FC−AL, EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 Express, FC−SW CLARiiON
PCI−X AX100
286 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)21, 26, 54, 72 AX100
287 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y74
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)21, 72, 75 AX100
288 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403619−B21)24, 47, 69 AX100
289 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ: Emulex LPe1105−HP 4Gb FC−AL, EMC Y
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL49 Express FC HBA for HP c−Class FC−SW CLARiiON
(407235−B21) Bladesystem (403621−B21)21, 72, AX100
75, QLogic QMH2462 4Gb FC HBA
for HP c−Class Bladesystem
(403619−B21)47, 69

11/02/2006 97 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
290 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0 AS/ES PCI−X Emulex LP101−E16, 19, 27, 78 FC−AL, EMC N1, 2
6650 v2.6.9−5.0.5.EL49 FC−SW CLARiiON
AX100
291 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0 AS/ES PCI−X QLogic QLA200−E−SP14, 27, 77 FC−AL, EMC N1, 2
2600, 2650, 6600, 6650; v2.6.9−5.0.5.EL49 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, RX600 S2, TX200
S2, TX300, TX300 S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS370, SS3840
292 Dell PowerEdge: 1600SC, 1650, 1750; Red Hat RHEL [32−Bit] 4.0 AS/ES PCI−X QLogic QLA2340−E−SP11, 27, 77 FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49 FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, AX100
RX600 S2, TX600 S2
293 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0 AS/ES v2.6.9−5.EL49 PCI−X Emulex LP101−E16, 19, 27, 78 FC−AL, EMC N1, 2
6650; FC−SW CLARiiON
AX100
IBM xSeries x3850/x366 (8863)81, 82
294 IBM xSeries x3850/x366 (8863)81, 82 Red Hat RHEL [32−Bit] 4.0 AS/ES v2.6.9−5.EL49 PCI−X Emulex: LP1050−E16, 18, 27, 109 , FC−AL, EMC Y
LP982−E16, 27, 109 FC−SW CLARiiON
AX100
295 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0 AS/ES v2.6.9−5.EL49 PCI−X QLogic QLA200−E−SP14, 27, 77 FC−AL, EMC N1, 2
2600, 2650, 6600, 6650; FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, RX600 S2, TX200
S2, TX300, TX300 S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
IBM xSeries x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS370, SS3840
296 Dell PowerEdge: 1600SC, 1650, 1750; Red Hat RHEL [32−Bit] 4.0 AS/ES v2.6.9−5.EL49 PCI−X QLogic QLA2340−E−SP11, 27, 77 FC−AL, EMC N1, 2
FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, AX100
RX600 S2, TX600 S2;
IBM xSeries x3850/x366 (8863)81, 82
297 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 4.0 AS/ES v2.6.9−5.EL49 PCI−X83 Emulex LP101−E16, 19, 27, 78 ; FC−AL, EMC N1, 2
x3950/x3950E/x460 (8872, 8874)81, 82 QLogic: QLA200−E−SP14, 27, 77, FC−SW CLARiiON
QLA2340−E−SP11, 27, 77 AX100
298 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 4.0 AS/ES v2.6.9−5.EL49 PCI−X83 Emulex: LP1050−E16, 18, 27, 109 , FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)81, 82 LP982−E16, 27, 109 FC−SW CLARiiON
AX100
299 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex LP101−E16, 19, 27, 100 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
300 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex: LP1050−E16, 18, 27, 50 , FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 27, 50 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AX100
301 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex: LP1050−E16, 18, 50, FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 50 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
302 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex LP1050Ex−E16, 19, 27, 50 FC−AL, EMC Y
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400 AX100
303 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex: LP101−E16, 19, 27, 100 , FC−AL, EMC N1, 2
2850 v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express LP1050−E16, 18, 27, 50 , LP982−E16, FC−SW CLARiiON
27, 50; AX100
QLogic: QLA200−E−SP14, 27, 77,
QLA2340−E−SP11, 27, 77
304 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI QLogic QLE2360−E−SP27, 36, 37, FC−AL, EMC N1, 2
2850, 6800, 6850; v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express 77 FC−SW CLARiiON
AX100
Digital Henge Revo: JS1400, JS2400

11/02/2006 98 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
305 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex LP101−E16, 19, 27, 100 ; FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express, QLogic QLA200−E−SP14, 27, 77 FC−SW CLARiiON
HPQ Proliant ML350(G4)13 PCI−X AX100
306 Dell PowerEdge: 6800, 6850 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex: LP1050−E16, 18, 27, 50 , FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express, LP982−E16, 27, 50; FC−SW CLARiiON
PCI−X AX100
QLogic QLA2340−E−SP11, 27, 77
307 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex: LP1050−E16, 18, 50, FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express, LP982−E16, 50 FC−SW CLARiiON
PCI−X AX100
308 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI Emulex: LP101−E16, 19, 27, 100 , FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 Express, LP1050−E16, 18, 50, LP982−E16, 50; FC−SW CLARiiON
PCI−X67 AX100
QLogic: QLA200−E−SP14, 27, 77,
QLA2340−E−SP11, 77
309 Dell PowerEdge: 1600SC, 1650, 1750; Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex LP101−E16, 19, 27, 100 FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 FC−SW CLARiiON
Digital Henge SH4500R4; AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS370, SS3840
310 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex LP101−E16, 27, 32, 100 FC−AL, EMC N1, 2
RX300, RX300 S2, RX600 S2, TX200 v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 FC−SW CLARiiON
S2, TX300, TX300 S2, TX600 S2 AX100
311 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex LP1050Ex−E16, 27, 32, 50 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 FC−SW CLARiiON
AX100
312 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP101−E16, 19, 78, FC−AL, EMC N1, 2
6650 v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP1050−E16, 18, 27, 78 , FC−SW CLARiiON
LP1050−E16, 18, 78, LP982−E16, 27, AX100
78, LP982−E16, 78;

QLogic: QLA200−E−SP14,
QLA2340−E−SP11
313 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP1050−E16, 18, 27, 50 , FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 27, 50 FC−SW CLARiiON
AX100
314 Sun: V20z, V40z Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP1050−E16, 18, 27, 100 , FC−AL, EMC Y1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 27, 100 ; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP11, 27, 77
315 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Emulex: LP1050−E16, 18, 50, FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL760 (G2)13, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 LP982−E16, 50 FC−SW CLARiiON
DL76013, ML570(G2)13; AX100
Samsung: SS370, SS3840
316 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
6650; v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, RX600 S2, TX200
S2, TX300, TX300 S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS370, SS3840
317 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, Emulex LP101−E16, 19, 27, 100 ; FC−AL, EMC N1, 2
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 PCI−X QLogic: QLA200−E−SP14, 27, 77, FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13; QLA2340−E−SP11, 77 AX100
Samsung SS140
318 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, Emulex: LP1050−E16, 18, 27, 100 , FC−AL, EMC Y1, 2
(Model 8848) v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 PCI−X LP982−E16, 27, 100 ; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP11, 27, 77
319 HPQ Proliant:DL14513,DL380(G2)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, Emulex: LP1050−E16, 18, 50, FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49 PCI−X LP982−E16, 50 FC−SW CLARiiON
DL385 , DL580(G2) , DL580(G3)13,
13 13 AX100
DL58513, ML370(G3)13, ML370(G4)13
320 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI QLogic QLA200−E−SP14, 27, 77 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
HPQ Proliant: DL32013, DL360(G2)13, v2.6.9−11.EL49
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013

11/02/2006 99 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
321 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI QLogic QLA2340−E−SP11, 27, 77 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AX100
Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
v2.6.9−11.EL49
322 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
DL36013, DL380(G2)13, DL380(G3)13, v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; FC−SW CLARiiON
DL38013, DL580(G2)13, DL58013, AX100
ML350(G2)13, ML350(G3)13, ML35013, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
ML370(G2)13, ML37013, ML530(G2)13, v2.6.9−11.EL49
ML530(G3)13, ML53013, ML57013,
ML75013
323 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; Express, FC−SW CLARiiON
PCI−X AX100
Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
v2.6.9−11.EL49
324 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI−X Dell 2342M11, 77 FC−AL, EMC N1, 2
v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
v2.6.9−11.EL49
325 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0 AS/ES: PCI, IBM 24P0960 (QLA2340)11, 27, 66, FC−AL, EMC Y1, 2
(Model 8848) v2.6.9−5.0.5.EL49, v2.6.9−5.EL49; PCI−X 77 FC−SW CLARiiON
AX100
Red Hat RHEL [32−Bit] 4.0 U1 AS/ES
v2.6.9−11.EL49
326 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex LP101−E16, 19, 27, 48 FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−11.EL49 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
327 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex: LP1050−E16, 18, 27, 48 , FC−AL, EMC N1, 2
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−11.EL49 LP982−E16, 27, 48 FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AX100
328 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex: LP1050−E16, 18, 48, FC−AL, EMC N1, 2
DL36013, DL58013, ML350(G2)13, v2.6.9−11.EL49 LP982−E16, 48 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
329 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 48 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−11.EL49 Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
330 Dell PowerEdge 2850 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI QLogic QLA200−E−SP14, 27, 59, 77 FC−AL, EMC Y, Y1, 2
v2.6.9−11.EL49 Express FC−SW CLARiiON
AX100
331 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI QLogic QLE2360−E−SP27, 36, 37, FC−AL, EMC Y1, 2
2850, 6800, 6850; v2.6.9−11.EL49 Express 77 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
332 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex: LP101−E16, 19, 27, 48 , FC−AL, EMC N1, 2
v2.6.9−11.EL49 Express, LP1050−E16, 18, 48, LP982−E16, 48; FC−SW CLARiiON
PCI−X AX100
QLogic QLA200−E−SP14, 27, 77
333 Dell PowerEdge: 1600SC, 1650, 1750; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP101−E16, 19, 27, 48 FC−AL, EMC N1, 2
v2.6.9−11.EL49 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)13, AX100
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13

11/02/2006 100 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
334 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP101−E16, 19, 27, 48 FC−AL, EMC Y1, 2
v2.6.9−11.EL49 FC−SW CLARiiON
Digital Henge INNO: HR−4850, AX100
HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230
335 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP101−E16, 27, 32, 48 FC−AL, EMC N1, 2
RX300, RX300 S2, TX200 S2, TX300, v2.6.9−11.EL49 FC−SW CLARiiON
TX300 S2 AX100
336 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP1050Ex−E16, 27, 32, 48 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.9−11.EL49 FC−SW CLARiiON
AX100
337 Dell PowerEdge: 6600, 6650 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP101−E16, 19, 27, 78 , FC−AL, EMC Y1, 2
v2.6.9−11.EL49 LP101−E16, 19, 78, LP1050−E16, 18, FC−SW CLARiiON
27, 76,
LP1050−E16, 18, 76, AX100
LP982−E16, 27, 76, LP982−E16, 76
338 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP1050−E16, 18, 27, 48 , FC−AL, EMC N1, 2
v2.6.9−11.EL49 LP982−E16, 27, 48; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP11, 27, 77
339 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP1050−E16, 18, 27, 48 , FC−AL, EMC Y1, 2
v2.6.9−11.EL49 LP982−E16, 27, 48; FC−SW CLARiiON
Digital Henge INNO: HR−4850, AX100
HR−6850; QLogic QLA2340−E−SP11, 27, 77
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z
340 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP1050−E16, 18, 48, FC−AL, EMC N1, 2
DL360(G4)13, DL56013, DL760 (G2)13, v2.6.9−11.EL49 LP982−E16, 48 FC−SW CLARiiON
DL76013, ML570(G2)13 AX100
341 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X HPQ Emulex−based FC−AL, EMC Y
v2.6.9−11.EL49 BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
22, 23, 48

342 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic QLA200−E−SP14, 27, 77 FC−AL, EMC N1, 2
6600, 6650; v2.6.9−11.EL49 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, TX200 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
343 Dell PowerEdge: 6600, 6650; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
v2.6.9−11.EL49 FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, AX100
RX300, RX300 S2, TX200 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13
344 Dell PowerEdge: 6600, 6650 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic: QLA200−E−SP14, FC−AL, EMC N1, 2
v2.6.9−11.EL49 QLA2340−E−SP11 FC−SW CLARiiON
AX100
345 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X67 Emulex: LP101−E16, 19, 27, 48 , FC−AL, EMC Y1, 2
v2.6.9−11.EL49 LP1050−E16, 18, 27, 48 , LP982−E16, FC−SW CLARiiON
27, 48; AX100
QLogic QLA2340−E−SP11, 27, 77
346 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y
v2.6.9−11.EL49 Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394757−B2116, 22, 23, 48 AX100
347 HPQ Proliant: BL25p, BL30p, BL35p Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y
v2.6.9−11.EL49 BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
22, 23, 48

11/02/2006 101 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
348 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X83 Emulex: LP101−E16, 19, 27, 48 , FC−AL, EMC Y1, 2
x3950/x3950E/x460 (8872, 8874)81, 82 v2.6.9−11.EL49 LP1050−E16, 18, 27, 48 , LP982−E16, FC−SW CLARiiON
27, 48; AX100
QLogic QLA2340−E−SP11, 27, 77
349 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, Emulex LP101−E16, 19, 27, 48 FC−AL, EMC Y1, 2
2650, 2800, 2850; v2.6.9−11.EL49 PCI−X FC−SW CLARiiON
AX100
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
350 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, Emulex: LP101−E16, 19, 27, 48 , FC−AL, EMC N1, 2
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−11.EL49 PCI−X LP1050−E16, 18, 48, LP982−E16, 48; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 QLogic QLA200−E−SP14, 27, 77
351 Dell PowerEdge: 1800, 1850, 2600, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, Emulex: LP1050−E16, 18, 27, 48 , FC−AL, EMC Y1, 2
2650, 2800, 2850; v2.6.9−11.EL49 PCI−X LP982−E16, 27, 48; FC−SW CLARiiON
AX100
IBM eServer: 325 (Model 8835), 326 QLogic QLA2340−E−SP11, 27, 77
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
352 Dell PowerEdge 2850 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, QLogic QLA200−E−SP14, 27, 59, 77 FC−AL, EMC Y1, 2
v2.6.9−11.EL49 PCI−X FC−SW CLARiiON
AX100
353 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, QLogic QLA2340−E−SP11, 77 FC−AL, EMC N1, 2
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−11.EL49 PCI−X FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13 AX100
354 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLogic: QLA200−E−SP14, 27, 40, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AS/ES v2.6.9−22.0.2.EL QLA210−E−SP14, 27, 40 AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
355 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050−E16, 27, 32, 43 ; FC−AL, EMC Y
S2F34, S234; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Fujitsu Siemens BX600−FC22Q11, FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL 27, 33 AX100
Fujitsu Siemens Primergy BX630:
(2−way), (4−way)
356 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP982−E16, 27, 43; FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AS/ES v2.6.9−22.0.2.EL AX100
QLogic QLA2340−E−SP11, 27, 40
357 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E16, 18, 43, FC−AL, EMC Y1, 39
DL36013, DL58013, ML350(G2)13, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP982−E16, 43 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AS/ES v2.6.9−22.0.2.EL AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
358 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y1, 39
140Hd, 140Rc−4, 180Rd−4 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ 35, 43 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
359 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI QLogic QLA2340−E−SP11, 40 FC−AL, EMC Y1, 39
DL36013, DL380(G2)13, DL380(G3)13, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
DL38013, DL580(G2)13, DL58013, AS/ES v2.6.9−22.0.2.EL AX100
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
360 Unisys ES7000/460 [64−Bit] Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Unisys: FCH7440131−PCX FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (LP1150)16, 28, 43, FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL FCH7440231−PCX (LP11002)16, AX100
28, 43, FCH752313−PCX
(LP1050)16, 19, 43
361 Dell PowerEdge: 1800, 2800, 2850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express QLogic: QLA200−E−SP14, 27, 40, FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL QLA210−E−SP14, 27, 40 AX100
Digital Henge Revo: JS1400, JS2400
362 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
2800, 2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express QLogic QLE2360−E−SP27, 36, 37, FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL 40 AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
Lenovo SureServer: R650, T650;
Samsung ZSS150
363 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LPe111−E16, 27, 43, 54 FC−AL, EMC Y1, 39
2800, 2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
Lenovo SureServer: R650, T650;
Samsung ZSS150

11/02/2006 102 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
364 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LPe1150−E16, 27, 42, 43 FC−AL, EMC Y1, 39
2800, 2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13
365 Digital Henge Revo: JS1400, JS2400; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LPe1150−E16, 27, 42, 64 FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express FC−SW CLARiiON
Lenovo SureServer: R650, T650; AS/ES v2.6.9−22.0.2.EL AX100
Samsung ZSS150
366 Dell PowerEdge: 1800, 2800, 2850 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express LP982−E16, 27, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
QLogic QLA2340−E−SP11, 27, 40
367 HPQ Proliant: DL360(G4)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI HPQ A8002A/FC2142SR FC−AL, EMC Y1, 39
DL380(G4)13, DL580(G3)13, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express (LPe1150)16, 27, 43, 68 FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 AS/ES v2.6.9−22.0.2.EL AX100
368 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI QLogic QLE2460−E−SP27, 40, 56 FC−AL, EMC Y1, 39
2800, 2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge Revo: JS1400, JS2400;
Lenovo SureServer: R650, T650;
Samsung ZSS150
369 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, QLogic: QLA200−E−SP14, 27, 40, FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X QLA210−E−SP14, 27, 40 AX100
HPQ Proliant ML350(G4)13
370 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
6850 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LP982−E16, 27, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X AX100
QLogic QLA2340−E−SP11, 27, 40
371 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E16, 18, 43, FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LP982−E16, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 40, 111 ,
AE369A/FC1243 (QLA2462)27, 40,
111;

QLogic QLA2340−E−SP11, 40
372 Dell PowerEdge: 2900, 2950; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E16, 19, 27, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LPe111−E16, 27, 43, 54 , FC−SW CLARiiON
IBM eServer 326m (Model 7969) AS/ES v2.6.9−22.0.2.EL PCI−X LPe1150−E16, 27, 42, 43 ; AX100
QLogic: QLE2360−E−SP27, 36, 37,
40, QLE2460−E−SP27, 40, 56

373 Fujitsu Siemens Primergy RX220 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E16, 27, 32, 119 , FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LPe1150−E16, 27, 43, 118 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X AX100
374 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP101−E16, 19, 27, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, LP1050−E16, 18, 43, LP982−E16, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X 67 AX100
QLogic: QLA200−E−SP14, 27, 40,
QLA210−E−SP14, 27, 40,
QLA2340−E−SP11, 40
375 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Dell: 2342M11, 2342M11, 40, FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LPe1105−M16, 27, 42, 43 , FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL QME246227, 40, 41 AX100
376 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLogic QLA200−E−SP14, 27, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
377 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E16, 19, 43; FC−AL, EMC Y1, 39
6650 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLogic QLA200−E−SP14, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
378 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050−E16, 18, 27, 43 FC−AL, EMC Y1, 39
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200

11/02/2006 103 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
379 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050Ex−E16, 27, 32, 43 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
380 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP982−E16, 27, 43 FC−AL, EMC Y1, 39
1850, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
381 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex: LP1050−E16, 18, 43, FC−AL, EMC Y1, 39
6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP982−E16, 43 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL760 (G2)13,
DL76013, ML570(G2)13;
Samsung: SS370, SS3840
382 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X HPQ Emulex−based FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ BL25/30/35/45p Fibre Channel FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL Mezzanine HBA − 394588−B2116, AX100
22, 23, 43

383 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (QLA2460)27, 40, 111 , FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AE369A/FC1243 (QLA2462)27, 40, AX100
111

384 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y1, 39
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ 35, 43 FC−SW CLARiiON
140Rd−4 AS/ES v2.6.9−22.0.2.EL AX100
385 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 35, FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ 43, 68 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
386 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 40 FC−AL, EMC Y1, 39
1850, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
387 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 27, 40 FC−AL, EMC Y1, 39
1850, 1950; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46, x3850/x366 (8863)81, 82;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
388 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP11, 40 FC−AL, EMC Y1, 39
6650; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
389 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2460−E−SP27, 40, 56 FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
390 Fujitsu Siemens Primergy: RX300 S2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic: QLA200−E−SP14, 27, 40, FC−AL, EMC Y
TX200 S2, TX300 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLA210−E−SP14, 27, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100

11/02/2006 104 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
391 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Fibre Channel Mezzanine HBA − FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL 394757−B2116, 22, 23, 43 AX100
392 HPQ Proliant: BL25p, BL30p, BL35p Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ BL25/30/35/45p Fibre Channel FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL Mezzanine HBA − 394588−B2116, AX100
22, 23, 43

393 IBM xSeries: x3800/x260 (8865)81, 82, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X83 Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
x3950/x3950E/x460 (8872, 8874)81, 82 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP982−E16, 27, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
QLogic QLA2340−E−SP11, 27, 40
394 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 42, 43 , FC−AL, EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Express, QME246227, 40, 41 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL PCI−X AX100
395 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex LP101−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X QLogic: QLA200−E−SP14, 27, 40, FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−22.0.2.EL QLA210−E−SP14, 27, 40 AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung SS140
396 Fujitsu Siemens Primergy: RX600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex LP1050−E16, 27, 32, 43 FC−AL, EMC Y
RX800 S2, TX600 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
397 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex: LP1050−E16, 18, 27, 43 , FC−AL, EMC Y1, 39
2850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X LP982−E16, 27, 43; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
IBM eServer: 325 (Model 8835), 326 QLogic QLA2340−E−SP11, 27, 40
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
398 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex: LP1050−E16, 18, 43, FC−AL, EMC Y1, 39
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X LP982−E16, 43 FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−22.0.2.EL AX100
DL58513, ML370(G3)13, ML370(G4)13
399 Fujitsu Siemens Primergy: RX600, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Fujitsu Siemens FC−AL, EMC Y
RX800, TX600 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X S26361−F2843−E1 (Emulex FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL LP9802)16, 32, 43 AX100
400 HPQ Proliant: DL380(G4)13, DL38513, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y1, 39
DL58513, ML370(G4)13 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X (QLA2460)27, 40, 111 , FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AE369A/FC1243 (QLA2462)27, 40, AX100
111

401 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, IBM 24P0960 (QLA2340)11, 27, 40, FC−AL, EMC Y1, 39
(Model 8848) v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X 66 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
402 Fujitsu Siemens Primergy RX800 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 115 FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
403 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic QLA2340−E−SP11, 40 FC−AL, EMC Y1, 39
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13; AS/ES v2.6.9−22.0.2.EL AX100
Samsung SS140
404 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic: QLA2340−E−SP11, 27, 40, FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X QLA2340−E−SP11, 40 FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL AX100
405 Fujitsu Siemens Primergy: RX300 S2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex: LP101−E16, 27, 32, FC−AL, EMC Y
TX200 S2, TX300 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ LP101−E16, 32, LP1050−E16, 27, 32; FC−SW CLARiiON
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, AX100
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Fujitsu Siemens
v2.6.9−34.0.2.EL S26361−F2843−E1 (Emulex
LP9802)16, 32;
QLogic QLA2340−E−SP11
406 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 43 ; FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, Express QLogic QLE2360−E−SP36, 37, 40 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230
407 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP101−E16, 19, 43, FC−AL, EMC Y1, 39
v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, Express LP1050−E16, 18, 43, LP982−E16, 27, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL 43, LP982−E16, 43; AX100
QLogic QLA2340−E−SP11, 40
408 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LPe111−E16, 27, 43, 54 , FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, Express LPe1150−E16, 27, 42, 64 ; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF520; QLogic: QLE2360−E−SP27, 36, 37,
40, QLE2460−E−SP27, 40, 56
Samsung ZSS230
409 LangChao: NC3000, NC3500, NF500, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050−E16, 18, 27, 43 ; FC−AL, EMC Y1, 39
NF520; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP11, 27, 40 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
Samsung ZSS230
410 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP982−E16, 27, 43 FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230

11/02/2006 105 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
411 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex: LP101−E16, 19, 43, FC−AL, EMC Y1, 39
HR−6850; v2.6.9−22.EL55, U2+ AS/ES v2.6.9−22.0.1.EL, LP1050−E16, 18, 43, LP982−E16, 43; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX100
LangChao: NC3000, NC3500, NF500, QLogic QLA2340−E−SP11, 40
NF520
412 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ QLogic: QLA200−E−SP14, 27, 80, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; AS/ES v2.6.9−34.0.2.EL QLA210−E−SP14, 27, 80 AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
413 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050−E16, 27, 32, 53 FC−AL, EMC Y
S2F34, S234; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy BX630:
(2−way), (4−way)
414 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP1050−E16, 18, 27, 53 , FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ LP982−E16, 27, 53; FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AS/ES v2.6.9−34.0.2.EL AX100
QLogic QLA2340−E−SP11, 27, 80
415 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP1050−E16, 18, 53, FC−AL, EMC Y
DL36013, DL58013, ML350(G2)13, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ LP982−E16, 53 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AS/ES v2.6.9−34.0.2.EL AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
416 Fujitsu Siemens Primergy BX620: Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Fujitsu Siemens BX600−FC22Q11, FC−AL, EMC Y
S2F34, S234, S3; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 27, 33, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy BX630:
(2−way), (4−way), (8−way)
417 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL36013, DL380(G2)13, DL380(G3)13, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 27, 28, 53 ; FC−SW CLARiiON
DL38013, DL580(G2)13, DL58013, AS/ES v2.6.9−34.0.2.EL QLogic: QLA2340−E−SP11, 80, AX100
ML350(G2)13, ML350(G3)13, ML35013, QLE220−E−SP27, 85, 102, 108
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
418 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 35, 53 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
419 Dell PowerEdge: 1800, 2800, 2850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express QLogic: QLA200−E−SP14, 27, 80, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL QLA210−E−SP14, 27, 80 AX100
Digital Henge Revo: JS1400, JS2400
420 Dell PowerEdge: 1800, 2800, 2850 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050−E16, 18, 27, 53 ; FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express QLogic QLA2340−E−SP11, 27, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
421 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 53 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
422 Dell PowerEdge: 1800, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP982−E16, 27, 53 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express FC−SW CLARiiON
Samsung ZSS230 AS/ES v2.6.9−34.0.2.EL AX100
423 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP101−E16, 19, 53, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express LP1050−E16, 18, 53, LP982−E16, 53; FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
QLogic QLA2340−E−SP11, 80
424 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LPe111−E16, 27, 53, 54 , FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express LPe1150−E16, 27, 42, 53 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
425 HPQ Proliant: DL360(G4)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y
DL380(G4)13, DL580(G3)13, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express (LPe1150)16, 27, 53, 68 , FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 AS/ES v2.6.9−34.0.2.EL AD167A/FC2143 (LP1150)16, 27, 28, AX100
53

11/02/2006 106 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
426 Dell PowerEdge 1950 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP27, 85, 102 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
427 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP27, 85, 102, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express 108 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
428 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE2360−E−SP27, 36, 37, FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
429 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE2360−E−SP36, 37, 80 FC−AL, EMC Y
HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230
430 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE2460−E−SP27, 56, 80 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
431 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, QLogic: QLA200−E−SP14, 27, 80, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X QLA210−E−SP14, 27, 80 AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
HPQ Proliant ML350(G4)13;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
432 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050−E16, 18, 27, 53 FC−AL, EMC Y
6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
IBM xSeries: x3550 (7978), x3650
(7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
433 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E16, 19, 27, 53 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS/ES v2.6.9−34.0.2.EL PCI−X AX100
AS2500;
Fujitsu Siemens Primergy: RX600 S3,
TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
434 Fujitsu Siemens Primergy: RX220, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E16, 27, 32, 53 ; FC−AL, EMC Y
RX600 S3, TX600 S3 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, QLogic QLA2340−E−SP11 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
435 Fujitsu Siemens Primergy RX220 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E16, 27, 53 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
436 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP982−E16, 27, 53 FC−AL, EMC Y
6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
437 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LPe111−E16, 27, 53, 54 ; FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, QLogic: QLE2360−E−SP27, 36, 37, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS/ES v2.6.9−34.0.2.EL PCI−X 80, QLE2460−E−SP27, 56, 80 AX100
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
438 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LPe1150−E16, 27, 42, 53 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS/ES v2.6.9−34.0.2.EL PCI−X AX100
AS2500;
Fujitsu Siemens Primergy: RX220,
RX600 S3, TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 107 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
439 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP1050−E16, 18, 53, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, LP982−E16, 53; FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 111, 112 ,
AD167A/FC2143 (LP1150)16, 27, 28,
53, AE369A/FC1243 (QLA2462)27,
101, 111;

QLogic QLE220−E−SP27, 85, 102,


108

440 IBM xSeries: x3550 (7978), x3650 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI IBM: 24P0960 (QLA2340)11, 27, 66, FC−AL, EMC Y
(7979) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, 80, 24P8053 (QLA2342)11, 27, 80, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X 39M5894 (QLA2460)27, 39M5895 AX100
(QLA2462)27;
QLogic: QLA2460−E−SP27, 56, 80,
QLE2360−E−SP27, 80, 98,
QLE2460−E−SP27, 80, 97
441 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI NEC: N8190−120 (LP1050)18, 35, FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, 116, 120, N8190−127 (LPe1150)35, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X 42, 116, 120 AX100
442 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP11, 27, 80 FC−AL, EMC Y
6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy: RX220,
RX600 S3, TX600 S3;
IBM xSeries: x3550 (7978), x3650
(7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
443 Fujitsu Siemens Primergy: RX220, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP11, 80 FC−AL, EMC Y
RX600 S3, TX600 S3; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
HPQ Proliant ML350(G4)13
444 Dell PowerEdge: 1850, 1900, 2850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP27, 85, 102 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
445 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP101−E16, 19, 27, 53 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, LP1050−E16, 18, 53, LP982−E16, 53; FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X 67 AX100
QLogic: QLA200−E−SP14, 27, 80,
QLA210−E−SP14, 27, 80,
QLA2340−E−SP11, 80,
QLE220−E−SP27, 85, 102, 108
446 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Dell: 2342M11, 80, LPe1105−M16, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 27, 42, 53 , QME246227, 41, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
447 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ QLogic QLA200−E−SP14, 27, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
448 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E16, 19, 53 FC−AL, EMC Y
6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
LangChao: NC3000, NC3500, NF500,
NF520
449 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP1050−E16, 18, 27, 53 FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200

11/02/2006 108 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
450 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP1050Ex−E16, 27, 32, 53 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
451 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP982−E16, 27, 53 FC−AL, EMC Y
1850, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
452 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex: LP1050−E16, 18, 53, FC−AL, EMC Y
6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ LP982−E16, 53 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL760 (G2)13,
DL76013, ML570(G2)13;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: SS370, SS3840
453 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL360(G4)13, DL56013, DL74013, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 27, 28, 53 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13 AS/ES v2.6.9−34.0.2.EL AX100
454 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(416654−B21), (416655−B21), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ HBA for HP c−Class Bladesystem: FC−SW CLARiiON
(416656−B21), (432636−B21); AS/ES v2.6.9−34.0.2.EL (403621−B21)53, 72, 104 , AX100
(403621−B21)53, 72, 110
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
455 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ Emulex−based FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ BL25/30/35/45p Fibre Channel FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL Mezzanine HBA − 394588−B2116, AX100
22, 23, 53

456 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(416654−B21), (416655−B21), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); AS/ES v2.6.9−34.0.2.EL (403619−B21)69, 101 AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
457 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (QLA2460)27, 111, 112 , FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AE369A/FC1243 (QLA2462) 27, 101, AX100
111

458 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 35, 53 FC−SW CLARiiON
140Rd−4 AS/ES v2.6.9−34.0.2.EL AX100
459 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 35, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 53, 68 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
460 Fujitsu Siemens Primergy: RX300 S2, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP14, 27 FC−AL, EMC Y
TX200 S2, TX300 S2 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
461 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP14, 80 FC−AL, EMC Y
6650 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
462 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 80 FC−AL, EMC Y
1850, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
Fujitsu Siemens Primergy: RX300 S2,
TX200 S2, TX300 S2;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840

11/02/2006 109 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
463 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP11, 27, 80 FC−AL, EMC Y
1850, 1950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
464 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP11, 80 FC−AL, EMC Y
6650; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
465 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA2460−E−SP27, 56, 80 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
466 Digital Henge SH4500R4; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLE220−E−SP27, 85, 102, FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ 108 FC−SW CLARiiON
TX200 S2, TX300 S2; AS/ES v2.6.9−34.0.2.EL AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
467 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Fibre Channel Mezzanine HBA − FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL 394757−B2116, 22, 23, 53 AX100
468 HPQ Proliant: BL25p, BL30p, BL35p Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ BL25/30/35/45p Fibre Channel FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL Mezzanine HBA − 394588−B2116, AX100
22, 23, 53

469 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, PCI Dell: LPe1105−M16, 27, 42, 53 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, QME246227, 41, 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
470 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, PCI QLogic QLE220−E−SP27, 85, 102 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL PCI−X AX100
471 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP101−E16, 19, 27, 53 ; FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X QLogic: QLA200−E−SP14, 27, 80, FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−34.0.2.EL QLA210−E−SP14, 27, 80, AX100
DL58513, ML370(G3)13, ML370(G4)13; QLE220−E−SP27, 85, 102, 108
Samsung SS140
472 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP1050−E16, 27, 32, 53 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
473 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E16, 18, 27, 53 , FC−AL, EMC Y
2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X LP982−E16, 27, 53 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
IBM eServer: 325 (Model 8835), 326
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
474 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E16, 18, 53, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X LP982−E16, 53; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−34.0.2.EL AX100
DL58513, ML370(G3)13, ML370(G4)13 HPQ AD167A/FC2143 (LP1150)16,
27, 28, 53

475 HPQ Proliant: DL380(G4)13, DL38513, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
DL58513, ML370(G4)13 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X (QLA2460)27, 111, 112 , FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AE369A/FC1243 (QLA2462)27, 101, AX100
111

11/02/2006 110 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
476 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, IBM 24P0960 (QLA2340)11, 27, 66, FC−AL, EMC Y
(Model 8848) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X 80 FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
477 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP11, 27, 80 FC−AL, EMC Y
2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X FC−SW CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy RX800 S2;
IBM eServer: 325 (Model 8835), 326
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
478 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP11, 80 FC−AL, EMC Y
HPQ Proliant: DL14513, DL380(G4)13, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AS/ES v2.6.9−34.0.2.EL AX100
DL58513, ML370(G3)13, ML370(G4)13;
Samsung SS140
479 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL QLogic: QLA200−E−SP14, 27, 47, FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450; QLA210−E−SP14, 27, 47 AX100
HPQ Proliant: DL32013, DL360(G2)13,
DL36013, DL380(G2)13, DL380(G3)13,
DL38013, DL580(G2)13, DL58013,
ML350(G2)13, ML350(G3)13, ML35013,
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
480 Dell PowerEdge: 1550, 2300, 2400, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E16, 18, 21, 27 , FC−AL, EMC Y
2450, 2500, 255045, 4300, 4350, 4400, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL LP982−E16, 21, 27; FC−SW CLARiiON
6100, 6300, 6350, 6400, 6450, 8450 AX100
QLogic QLA2340−E−SP11, 27, 47
481 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E16, 18, 21, FC−AL, EMC Y
DL36013, DL58013, ML350(G2)13, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL LP982−E16, 21 FC−SW CLARiiON
ML350(G3)13, ML35013, ML370(G2)13, AX100
ML37013, ML530(G2)13, ML530(G3)13,
ML53013, ML57013, ML75013
482 HPQ Proliant: DL32013, DL360(G2)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL36013, DL380(G2)13, DL380(G3)13, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 27, 28 ; FC−SW CLARiiON
DL38013, DL580(G2)13, DL58013, QLogic: QLA2340−E−SP11, 47, AX100
ML350(G2)13, ML350(G3)13, ML35013, QLE220−E−SP27, 84, 85
ML370(G2)13, ML37013, ML530(G2)13,
ML530(G3)13, ML53013, ML57013,
ML75013
483 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 35 FC−SW CLARiiON
AX100
484 Dell PowerEdge: 1800, 2800, 2850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic: QLA200−E−SP14, 27, 47, FC−SW CLARiiON
QLA210−E−SP14, 27, 47 AX100
Digital Henge Revo: JS1400, JS2400
485 Dell PowerEdge: 1800, 2800, 2850 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP1050−E16, 18, 21, 27 ; FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic QLA2340−E−SP11, 27, 47 FC−SW CLARiiON
AX100
486 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP1050Ex−E16, 19, 21, 27 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
487 Dell PowerEdge: 1800, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP982−E16, 21, 27 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
Samsung ZSS230 AX100
488 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP101−E16, 19, 21, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express LP1050−E16, 18, 21, LP982−E16, 21; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP11, 47
489 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LPe111−E16, 21, 27, 54 , FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express LPe1150−E16, 21, 27, 42 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 111 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
490 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y1, 39
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), (403621−B21)21, 54, 72 AX100
(432636−B21);
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
491 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y74
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), (403621−B21)21, 72, 75 AX100
(432636−B21);
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
492 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), (403619−B21)47, 69 AX100
(432636−B21);
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
493 HPQ Proliant: DL360(G4)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y
DL380(G4)13, DL580(G3)13, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express (LPe1150)16, 21, 27, 68 , FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 AD167A/FC2143 (LP1150)16, 21, 27, AX100
28

494 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ: Emulex LPe1105−HP 4Gb FC−AL, EMC Y
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC HBA for HP c−Class FC−SW CLARiiON
(416655−B21), (416656−B21), Bladesystem (403621−B21)21, 72, AX100
(432636−B21); 75, QLogic QMH2462 4Gb FC HBA
for HP c−Class Bladesystem
HPQ Proliant BL465c: (403433−B21), (403619−B21)47, 69
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
495 IBM xSeries x3455 (7984) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI IBM: 42C2069 (LPe11000)16, 21, 27, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express 68,42C2071 (LPe11002)16, 21, 27, FC−SW CLARiiON
42; AX100
QLogic: QLE2360−E−SP27, 37, 47,
QLE2362−E−SP27, 37, 47,
QLE2462−E−SP27, 47, 56
496 Dell PowerEdge 1950; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
497 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP27, 36, 37, FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express 47 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)46;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
498 Digital Henge INNO: HR−4850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP36, 37, 47 FC−AL, EMC Y
HR−6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung ZSS230
499 Dell PowerEdge: 1800, 1850, 1950, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2460−E−SP27, 47, 56 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 112 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
500 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
6850, 6950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, QLogic: QLA200−E−SP14, 27, 47, FC−SW CLARiiON
PCI−X QLA210−E−SP14, 27, 47 AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
HPQ Proliant ML350(G4)13;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
501 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP1050−E16, 18, 21, 27 ; FC−AL, EMC Y
6850, 6950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, QLogic QLA2340−E−SP11, 27, 47 FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
IBM xSeries: x3550 (7978), x3650
(7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
502 Dell PowerEdge: 2900, 2950, 6800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP982−E16, 21, 27 FC−AL, EMC Y
6850, 6950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
503 HPQ Proliant ML350(G4)13 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E16, 18, 21, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E16, 21; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143
(QLA2460)27, 47, 111 ,
AD167A/FC2143 (LP1150)16, 21, 27,
28, AE369A/FC1243 (QLA2462)27,
47, 111;

QLogic QLA2340−E−SP11, 47
504 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050Ex−E16, 19, 21, 27 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LPe111−E16, 21, 27, 54 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X LPe1150−E16, 21, 27, 42 ; AX100
AS2500;
QLogic: QLE2360−E−SP27, 36, 37,
Intel: SR1500/S5000PAL, 47, QLE2460−E−SP27, 47, 56
SR2500/S5000PAL
505 IBM xSeries: x3550 (7978), x3650 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI IBM: 24P0960 (QLA2340)11, 27, 47, FC−AL, EMC Y
(7979), x3755 (8877) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, 66, 24P8053 (QLA2342)11, 27, 47; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA2460−E−SP27, 47, 56,
QLE2360−E−SP27, 47, 98,
QLE2460−E−SP27, 47, 97
506 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI NEC: N8190−120 (LP1050)18, 21, FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, 35, 116, N8190−127 (LPe1150)21, FC−SW CLARiiON
PCI−X 35, 42, 116 AX100
507 Dell PowerEdge: 1850, 1900, 2850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550,
AS2500;
HPQ Proliant ML350(G4)13;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
508 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP101−E16, 19, 21, 27 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP1050−E16, 18, 21, LP982−E16, 21; FC−SW CLARiiON
PCI−X 67 AX100
QLogic: QLA200−E−SP14, 27, 47,
QLA210−E−SP14, 27, 47,
QLA2340−E−SP11, 47,
QLE220−E−SP27, 84, 85
509 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Dell: 2342M11, 47, LPe1105−M16, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 27, 42 , QME246227, 41, 47 FC−SW CLARiiON
AX100
510 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E16, 19, 21 FC−AL, EMC Y
6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
LangChao: NC3000, NC3500, NF500,
NF520
511 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL QLogic QLA200−E−SP14, 27, 47 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840

11/02/2006 113 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
512 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP1050−E16, 18, 21, 27 FC−AL, EMC Y
1850, 1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
513 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP982−E16, 21, 27 FC−AL, EMC Y
1850, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
514 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex: LP1050−E16, 18, 21, FC−AL, EMC Y
6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL LP982−E16, 21 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL760 (G2)13,
DL76013, ML570(G2)13;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: SS370, SS3840
515 HPQ Proliant: BL40p, DL360(G3)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X HPQ AD167A/FC2143 (LP1150)16, FC−AL, EMC Y
DL360(G4)13, DL56013, DL74013, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 27, 28 FC−SW CLARiiON
DL760 (G2)13, DL76013, ML570(G2)13 AX100
516 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X HPQ Emulex−based FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
21, 22, 23

517 HPQ Proliant DL360(G4)13 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (QLA2460)27, 47, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 47, AX100
111

518 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−120 (LP1050)16, 19, FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 21, 35 FC−SW CLARiiON
140Rd−4 AX100
519 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−127 (LPe1150)16, 21, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL 35, 68 FC−SW CLARiiON
AX100
520 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA200−E−SP14, 47 FC−AL, EMC Y
6650 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
521 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA210−E−SP14, 27, 47 FC−AL, EMC Y
1850, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840

11/02/2006 114 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
522 Dell PowerEdge: 1600SC, 1650, 1750, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA2340−E−SP11, 27, 47 FC−AL, EMC Y
1850, 1950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)46, x346
(8840)46;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
523 Dell PowerEdge: 2600, 2650, 6600, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA2340−E−SP11, 47 FC−AL, EMC Y
6650; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850,
HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
524 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA2460−E−SP27, 47, 56 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
525 Digital Henge SH4500R4; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
TX200 S2, TX300 S2; AX100
HPQ Proliant: BL40p, DL360(G3)13,
DL360(G4)13, DL56013, DL74013,
DL760 (G2)13, DL76013, ML570(G2)13;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003;
Samsung: SS210, SS370, SS3840
526 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X9 HPQ Emulex−based BL20p (G3) FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394757−B2116, 21, 22, 23 AX100
527 HPQ Proliant: BL25p, BL30p, BL35p Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X9 HPQ Emulex−based FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B2116, AX100
21, 22, 23

528 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI Dell: LPe1105−M16, 21, 27, 42 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, QME246227, 41, 47 FC−SW CLARiiON
PCI−X AX100
529 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI Emulex: LP101−E16, 19, 21, 27 , FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP1050−E16, 18, 21, LP982−E16, 21, FC−SW CLARiiON
PCI−X LPe111−E16, 21, 27, 54 , AX100
LPe1150−E16, 21, 27, 42 ;
HPQ: A8002A/FC2142SR
(LPe1150)16, 21, 27, 68 ,
AD167A/FC2143 (LP1150)16, 21, 27,
28, AE311A/FC1142SR
(QLE2460)27, 47, 56,
AE312A/FC1242SR (QLE2462)27,
47, 56;

QLogic: QLA200−E−SP14, 27, 47,


QLA210−E−SP14, 27, 47,
QLA2340−E−SP11, 47,
QLE2460−E−SP27, 47, 56,
QLE2462−E−SP27, 47, 56
530 HPQ Proliant DL380(G5) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI HPQ: AB429A/FC1143 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, (QLA2460)27, 47, 111 , FC−SW CLARiiON
PCI−X AE369A/FC1243 (QLA2462)27, 47, AX100
111

531 Dell PowerEdge: 1800, 2800; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP27, 84, 85 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) PCI−X AX100
532 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex LP101−E16, 19, 21, 27 ; FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLA200−E−SP14, 27, 47, FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, QLA210−E−SP14, 27, 47, AX100
DL58513, ML370(G3)13, ML370(G4)13; QLE220−E−SP27, 84, 85
Samsung SS140
533 Dell PowerEdge: 1800, 1850, 2800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E16, 18, 21, 27 , FC−AL, EMC Y
2850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X LP982−E16, 21, 27; FC−SW CLARiiON
AX100
IBM eServer: 325 (Model 8835), 326 QLogic QLA2340−E−SP11, 27, 47
(Model 8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140

11/02/2006 115 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
534 HPQ Proliant: DL14513, DL380(G2)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E16, 18, 21, FC−AL, EMC Y
DL380(G3)13, DL380(G4)13, DL38013, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X LP982−E16, 21; FC−SW CLARiiON
DL38513, DL580(G2)13, DL580(G3)13, AX100
DL58513, ML370(G3)13, ML370(G4)13 HPQ AD167A/FC2143 (LP1150)16,
21, 27, 28

535 HPQ Proliant: DL380(G4)13, DL38513, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, HPQ: AB429A/FC1143 FC−AL, EMC Y
DL58513, ML370(G4)13 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X (QLA2460)27, 47, 111 , FC−SW CLARiiON
AE369A/FC1243 (QLA2462)27, 47, AX100
111

536 IBM eServer: 325 (Model 8835), 326 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, IBM 24P0960 (QLA2340)11, 27, 47, FC−AL, EMC Y
(Model 8848) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X 66 FC−SW CLARiiON
AX100
537 HPQ Proliant: DL14513, DL380(G4)13, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, QLogic QLA2340−E−SP11, 47 FC−AL, EMC Y
DL38513, DL580(G2)13, DL580(G3)13, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X FC−SW CLARiiON
DL58513, ML370(G3)13, ML370(G4)13; AX100
Samsung SS140
538 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X), 8843) v2.4.21−20.EL7 (13N2203)11, 38, 73 CLARiiON
AX100
539 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U3 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
v2.4.21−20.EL7 (26K4841)11, 27, 38, 73 CLARiiON
AX100
540 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0 U4+ AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X), 8843) v2.4.21−27.0.1.EL7, 8 (13N2203)4, 11, 38, 73 CLARiiON
AX100
541 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X IBM HS20 FC Exp Card FC−SW EMC Y1, 2
v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; (26K4841)11, 12, 27, 38 CLARiiON
AX100
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
542 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−32.EL6, 7, 8, v2.4.21−32.EL7, 8; (13N2203)11, 12, 27, 38 , CLARiiON
(48P7061)11, 12, 27, 38 AX100
IBM BladeCenter HS40 (Model 8839) Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL7, 8
543 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−40.EL7, 25 Dual port: for NovaScale Blade CLARiiON
Series CFSN202−110030, 86, 108 , AX100
mini for NovaScale Blade 2021
CFSN202−210030, 86, 108 ;
Bull: SBEFCM (SFF) Mezzanine
HBA30, 86, 108 , SBEFCM4 (SFF)
4Gb Mezzanine HBA30, 57, 108
544 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Digital Henge Digital Henge: FC−SW EMC Y
v2.4.21−40.EL7, 25 SBEFCM427, 30, 57, SBEFCM30, 86, CLARiiON
108, SBFCM30, 86, 108 ; AX100
Digital Henge Intel (r) Fibre
Channel Module AHWFCMOD27,
30, 105, 108

545 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre FC−SW EMC Y
8843); v2.4.21−40.EL7, 25 Channel Exp Card (39Y9186)27, 31, CLARiiON
70, 71 AX100
IBM BladeCenter LS20 (Model 8850)
546 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
LS20 (Model 8850) v2.4.21−40.EL7, 25 (26R0890)27, 29, 57 CLARiiON
AX100
547 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y
v2.4.21−40.EL7, 25 (26K4841)11, 27, 29 CLARiiON
AX100
548 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−40.EL7, 25 (13N2203)11, 27, 29, (48P7061)11, CLARiiON
27, 29 AX100
IBM BladeCenter HS40 (Model 8839)
549 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.4.21−40.EL7, 25 for IBM eServer LS2011, 27, 29, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 29
550 IBM BladeCenter HS21 (Model 8853)99 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre FC−SW EMC Y96
v2.4.21−40.EL7, 25 Channel Exp Card (39Y9186)27, 31, CLARiiON
70, 114, HS20 4GB SFF FC Exp AX100
Card (26R0890)27, 29, 57, 59 , HS20
FC Exp Card (13N2203)11, 27, 29,
HS20 FC Exp Card (48P7061)11,
27, 29

551 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−40.EL7, 25 Card16, 27, 31, 52 , HS20 4GB CLARiiON
Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)27, 29, 51
LS20 (Model 8850)
552 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−47.EL7, 25 Dual port: for NovaScale Blade CLARiiON
Series CFSN202−1100105, 107, AX100
mini for NovaScale Blade 2021
CFSN202−2100105, 107, mini for
NovaScale Blade 2021
CFSN202−210086, 87;
Bull: SBEFCM (SFF) Mezzanine
HBA105, 107, SBEFCM4 (SFF) 4Gb
Mezzanine HBA106, 107

11/02/2006 116 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
553 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Digital Henge Digital Henge: FC−SW EMC Y
v2.4.21−47.EL7, 25 SBEFCM427, 106, 107 , SBEFCM105, CLARiiON
107, SBFCM105, 107; AX100
Digital Henge Intel (r) Fibre
Channel Module AHWFCMOD27,
105, 107

554 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre FC−SW EMC Y
8843); v2.4.21−47.EL7, 25 Channel Exp Card (39Y9186)26, 27, CLARiiON
70, 71 AX100
IBM BladeCenter: LS20 (Model 8850),
LS21 (Model 7971), LS41 (Model 7972)
555 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−47.EL7, 25 (13N2203)11, 24, 27, (48P7061)11, CLARiiON
24, 27 AX100
IBM BladeCenter HS40 (Model 8839)
556 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.4.21−47.EL7, 25 for IBM eServer LS2011, 24, 27, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 24, 27
557 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y
LS20 (Model 8850), LS21 (Model 7971), v2.4.21−47.EL7, 25 (26R0890)24, 27, 57, FC Exp Card CLARiiON
LS41 (Model 7972) (26K4841)11, 24, 27 AX100
558 IBM BladeCenter HS21 (Model 8853)99 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre FC−SW EMC Y96
v2.4.21−47.EL7, 25 Channel Exp Card (39Y9186)26, 27, CLARiiON
70, 114, HS20 4GB SFF FC Exp AX100
Card (26R0890)24, 27, 57, 59 , HS20
FC Exp Card (13N2203)11, 24, 27,
HS20 FC Exp Card (48P7061)11,
24, 27

559 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−47.EL7, 25 Card16, 26, 27, 52 , HS20 4GB CLARiiON
Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)24, 27, 51
LS20 (Model 8850)
560 IBM BladeCenter HS20 (Model Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X) v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.2.EL7, (13N2203)11, 38, 73 CLARiiON
U2+ AS/ES v2.4.21−15.0.3.EL7, U2+ AS/ES AX100
v2.4.21−15.0.4.EL7
561 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
v2.4.21−15.EL7, U2+ AS/ES v2.4.21−15.0.4.EL7 (26K4841)11, 27, 38, 65, 73 CLARiiON
AX100
562 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.1.EL7, 8, (26K4841)4, 11, 27, 38, 73 CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL7, 8, U4+ AS/ES AX100
v2.4.21−27.0.4.EL7, 8
563 IBM BladeCenter HS20 (Model: Red Hat RHEL [32−Bit] 3.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC N1, 2
8832−N1X), 8832−N1X)95, 8843) v2.4.21−27.EL7, U4+ AS/ES v2.4.21−27.0.2.EL7, 8, (13N2203)4, 11, 38, 73 CLARiiON
U4+ AS/ES v2.4.21−27.0.4.EL7, 8 AX100
564 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM Emulex LP1005DC FC Exp FC−SW EMC Y1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Card16, 27, 44, 52 CLARiiON
AX100
IBM BladeCenter: HS40 (Model 8839),
LS20 (Model 8850)
565 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC N1, 2
LS20 (Model 8850) v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (26R0890)27, 29, 57 CLARiiON
AX100
566 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 4GB Standard FC Exp FC−SW EMC N1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Card (26R0884)27, 29, 51 CLARiiON
AX100
IBM BladeCenter: HS40 (Model 8839),
LS20 (Model 8850)
567 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (26K4841)11, 27, 29 CLARiiON
AX100
568 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y1, 2
8678)63, 8832)63, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (13N2203)11, 27, 29, (48P7061)11, CLARiiON
27, 29 AX100
IBM BladeCenter HS40 (Model 8839)
569 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y1, 2
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL for IBM eServer LS2011, 27, 29, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 29
570 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL; Dual port for NovaScale Blade CLARiiON
Series: CFSN202−110086, 87, 88, AX100
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES 89, CFSN202−110086, 87, 88, 89, 90 ,
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ CFSN202−110086, 87, 91, 92 ;
AS/ES v2.6.9−22.0.2.EL
Bull 2Gbps FC Mezzanine Card −
Dual port mini for NovaScale Blade
2021: CFSN202−210086, 87, 88, 89 ,
CFSN202−210086, 87, 88, 89, 90 ,
CFSN202−210086, 87, 91, 92 ;
Bull SBEFCM (SFF) Mezzanine:
HBA27, 86, 87, 88, 89 , HBA27, 86, 87,
88, 89, 90 , HBA27, 86, 87, 91, 92

571 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull SBEFCM (SFF) Mezzanine FC−SW EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25 HBA27, 86, 87 CLARiiON
AX100

11/02/2006 117 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
572 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−40.EL7, 25, U8 AS/ES v2.4.21−47.EL7, 25; Dual port for NovaScale Blade CLARiiON
Series CFSN202−110086 AX100
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+
AS/ES v2.6.9−34.0.2.EL
573 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y1, 39
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (13N2203)11, 27, 40, (48P7061)11, CLARiiON
AS/ES v2.6.9−22.0.2.EL 27, 40 AX100
IBM BladeCenter HS40 (Model 8839)
574 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (26R0890)27, 57, 58, 59 , FC Exp CLARiiON
AS/ES v2.6.9−22.0.2.EL Card (26K4841)11, 27, 40 AX100
575 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y1, 39
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (26R0890)27, 57, FC Exp Card CLARiiON
AS/ES v2.6.9−22.0.2.EL (13N2203) for IBM eServer LS2011, AX100
27, 40, FC SFF Exp Card (26K4841)
for IBM eServer LS2011, 27, 40
576 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y1, 39
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ Card16, 27, 43, 52 , HS20 4GB CLARiiON
AS/ES v2.6.9−22.0.2.EL Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)27, 40, 51
LS20 (Model 8850)
577 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Dual port: for NovaScale Blade CLARiiON
AS/ES v2.6.9−34.0.2.EL Series CFSN202−110080, 105, mini AX100
for NovaScale Blade 2021
CFSN202−2100105, 113;
Bull SBEFCM (SFF) Mezzanine:
HBA27, 86, HBA80, 105;
Bull SBEFCM4 (SFF) 4Gb
Mezzanine HBA80, 106
578 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Digital Henge Digital Henge: FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ SBEFCM427, 80, 106 , SBEFCM80, CLARiiON
AS/ES v2.6.9−34.0.2.EL 105, SBFCM80, 105; AX100
Digital Henge Intel (r) Fibre
Channel Module AHWFCMOD27,
80, 105

579 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
HS21 (Model 8853)99 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (26R0890)27, 57, 59, 80 CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
580 IBM BladeCenter: HS21 (Model Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)99, LS20 (Model 8850) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (26R0890)27, 57, 80 CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
581 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (26K4841)11, 27, 80 CLARiiON
AS/ES v2.6.9−34.0.2.EL AX100
582 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ (13N2203)11, 27, 80, (48P7061)11, CLARiiON
AS/ES v2.6.9−34.0.2.EL 27, 80 AX100
IBM BladeCenter: HS21 (Model
8853)99, HS40 (Model 8839)
583 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ for IBM eServer LS2011, 27, 80, SFF CLARiiON
AS/ES v2.6.9−34.0.2.EL Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 80
584 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ Card16, 27, 52, 53 , HS20 4GB CLARiiON
AS/ES v2.6.9−34.0.2.EL Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)27, 51, 80
LS20 (Model 8850)
585 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Dual port for NovaScale Blade CLARiiON
Series: CFSN202−110047, 105, AX100
CFSN202−110047, 86;
Bull 2Gbps FC Mezzanine Card −
Dual port mini for NovaScale Blade
2021: CFSN202−210047, 105,
CFSN202−210047, 86;
Bull SBEFCM (SFF) Mezzanine:
HBA27, 47, 86, HBA47, 105;
Bull SBEFCM4 (SFF) 4Gb
Mezzanine HBA47, 106
586 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Digital Henge Digital Henge: FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL SBEFCM427, 47, 106 , SBEFCM47, CLARiiON
105, SBFCM47, 105; AX100
Digital Henge Intel (r) Fibre
Channel Module AHWFCMOD27,
47, 105

587 IBM BladeCenter: HS21 (Model Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)99, LS20 (Model 8850), LS21 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (26R0890)27, 47, 57 CLARiiON
(Model 7971), LS41 (Model 7972) AX100
588 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
HS21 (Model 8853)99 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (26R0890)27, 47, 57, 59 CLARiiON
AX100

11/02/2006 118 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
589 IBM BladeCenter: HS20 (Model 8843), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card FC−SW EMC Y
LS20 (Model 8850), LS21 (Model 7971), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (26K4841)11, 27, 47 CLARiiON
LS41 (Model 7972) AX100
590 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (13N2203)11, 27, 47, (48P7061)11, CLARiiON
27, 47 AX100
IBM BladeCenter: HS21 (Model
8853)99, HS40 (Model 8839)
591 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL for IBM eServer LS2011, 27, 47, SFF CLARiiON
Exp Card (26K4841) for IBM AX100
eServer LS2011, 27, 47
592 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8678)63, 8832)63, 8832−N1X), 8843); v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Card16, 21, 27, 52 , HS20 4GB CLARiiON
Standard FC Exp Card AX100
IBM BladeCenter: HS40 (Model 8839), (26R0884)27, 47, 51
LS20 (Model 8850)
593 Bull NovaScale 2320 Red Hat RHEL [32−Bit]: 3.0 U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.4.21−40.EL7, 25, 4.0 U3 AS/ES v2.6.9−34.EL, Dual port mini for NovaScale Blade CLARiiON
4.0 U3+ AS/ES v2.6.9−34.0.1.EL, 4.0 U3+ AS/ES 2021 CFSN202−210086 AX100
v2.6.9−34.0.2.EL
1. VxVM is not supported on servers booting from the array.
2. Booting from the SAN with PowerPath is not supported.
3. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 7.01.01 Driver is integrated into the kernel.
5. Driver Version 7.03.00 QLogic driver obtained from http://www.qlogic.com
6. Tested as an installable file system on a Linux cluster
Ibrix Fusion File system version 1.3 is supported with this configuration.
FusionFS Server Appliance Requirements:
CPU− x86, Xeon, 3+GHz, 2GB RAM
SMP Not Supported
NIC −Intel Pro 1000 Server adapter with 5.2.39 or BroadcomBCM5700
Please check E−Lab Navigator for the latest version of PowerPath supported on this configuration.
7. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
8. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file
names must be used.
9. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
10. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
13. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
14. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Driver Version 7.03.00
16. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
17. Driver Version 7.1.14 Driver is integrated into the kernel.
18. Firmware Version 1.91a5
19. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
20. Driver Version 7.1.14
21. Driver Version 8.0.16.27 Driver is integrated into the kernel.
22. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
23. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
25. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
26. Driver Version 7.3.6 Driver is integrated into the kernel.
27. SNIA HBA API Supported.
28. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
29. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
30. Driver Version 7.07.00
31. Driver Version 7.3.3 Driver is integrated into the kernel.
32. Firmware Version 1.91a1
33. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
34. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
35. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
36. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
37. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
38. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
39. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
40. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
41. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
42. Firmware Version 2.50a6
43. Driver Version 8.0.16.17 Driver is integrated into the kernel.
44. Driver Version 7.3.2 Driver is integrated into the kernel.
45. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
46. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
47. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
48. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
49. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
50. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
51. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
52. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
53. Driver Version 8.0.16.18 Driver is integrated into the kernel.
54. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
55. dual core machine not support
56. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
57. BIOS 1.12
58. Driver Version 8.01.00
59. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
60. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
61. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
62. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
63. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
64. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
65. Driver Version 6.07.02−RH2 Driver is integrated into the kernel.

11/02/2006 119 CLARiiON AX100


CLARiiON AX100

66. This HBA is equivalent to the QLogic QLA2340.


67. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
68. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
69. BIOS 1.16
70. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
71. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
72. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
73. Due to the HS20's embedded FC−SW design, array lun masking is required to assign LUNS to each individual blade server.
74. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
75. Firmware Version 2.50a8
76. Driver Version 8.0.16.6_x2
77. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
78. Driver Version 8.0.16.6_x2−2
79. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
80. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
81. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
82. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
83. Accepts PCI−X 1.0 and 2.0 HBAs.
84. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
85. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
86. BIOS 1.43
87. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
88. Driver Version 9.1.2.15 STORPort Miniport Driver
89. Driver Version 9.1.2.16 STORPort Miniport Driver
90. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
91. Driver Version 9.1.2.11
92. Driver Version 9.1.2.10
93. BIOS 1.02
94. Driver Version 7.07.05
95. PowerPath not currently supported.
96. PowerPath is not supported.
97. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
98. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
99. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
100. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
101. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
102. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
103. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
104. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
105. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com
106. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
107. Driver Version 7.07.04b6 Driver is integrated into the kernel.
108. Driver/BIOS are available at http://www.qlogic.com
109. Driver Version 8.0.16.6_x2−2 Driver is integrated into the kernel.
110. Firmware Version 2.50a8 Driver is integrated into the kernel.
111. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
112. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
113. Driver Version 8.01.−2−d4 Driver is integrated into the kernel.
114. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
115. Driver Version 8.01.00 Driver is integrated into the kernel.
116. BIOS 1.70a3
117. Driver Version 7.00.03 QLogic driver obtained from http://www.qlogic.com
118. Firmware Version 2.50a4 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
119. Driver Version 8.01.16.17
120. Driver Version 8.0.16.18

Red Hat RHEL [AMD−64]

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0 U7 PCI Emulex: LP101−E2, 4, 18, 27 , LP1050−E1, 2, 4, 27, LP1050Ex−E2, 4, FC−AL, EMC Y
AS/ES v2.4.21−40.EL24, 25 Express, 18, 27, LP982−E2, 4, 27, LPe111−E2, 4, 13, 27 , LPe1150−E2, 4, 27, 33 ; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA200−E−SP2, 15, 34, QLA210−E−SP2, 10, 15,
QLA2340−E−SP2, 7, 10, QLE2360−E−SP2, 10, 41, 42 ,
QLE2460−E−SP2, 10, 32
2 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0 U7 PCI−X Emulex: LP101−E2, 4, 18, 27 , LP1050−E1, 2, 4, 27, LP982−E2, 4, 27; FC−AL, EMC Y
x4100, x4200 AS/ES v2.4.21−40.EL24, 25 FC−SW CLARiiON
QLogic: QLA200−E−SP2, 10, 15, QLA210−E−SP2, 10, 15, AX100
QLA2340−E−SP7, 10, QLE220−E−SP2, 30, 55, 56
3 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0 U7 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y
AS/ES v2.4.21−40.EL24, 25 BL25p/BL45p 381881−B2110, 40, Emulex−based BL25/30/35/45p FC−SW CLARiiON
Fibre Channel Mezzanine HBA − 394588−B214, 27, 46, 47 AX100
4 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 3.0 U7 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.4.21−40.EL24, 25 HBA − 394588−B214, 27, 46, 47 FC−SW CLARiiON
AX100
5 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0 U7 PCI, Emulex: LP101−E2, 4, 18, 27 , LP1050−E1, 4, 27, LP982−E4, 27; FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.4.21−40.EL24, 25 PCI−X FC−SW CLARiiON
DL58521 HPQ AD167A/FC2143 (LP1150)2, 4, 27, 45 ; AX100
QLogic: QLA200−E−SP2, 10, 15, QLA210−E−SP2, 10, 15,
QLA2340−E−SP7, 10, QLE220−E−SP2, 30, 55, 56
6 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 3.0 U8 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y5, 6
(403433−B21), AS/ES v2.4.21−47.EL24, 25 Express Bladesystem (403621−B21)13, 39, 49 FC−SW CLARiiON
(403434−B21), AX100
(407234−B21),
(407235−B21)

11/02/2006 120 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
7 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 3.0 U8 PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), AS/ES v2.4.21−47.EL24, 25 Express (403619−B21)35, 43 FC−SW CLARiiON
(403434−B21), AX100
(407234−B21),
(407235−B21)
8 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0 U8 PCI Emulex: LP101−E2, 4, 18, 39 , LP1050−E1, 2, 4, 39, LP1050Ex−E2, 4, FC−AL, EMC Y
AS/ES v2.4.21−47.EL24, 25 Express, 18, 39, LP982−E2, 4, 39, LPe111−E2, 4, 13, 39 , LPe1150−E2, 4, 33, 39 ; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA200−E−SP2, 15, 43, QLA210−E−SP2, 15, 43,
QLA2340−E−SP2, 7, 43, QLE2360−E−SP2, 42, 43, QLE2460−E−SP2,
32, 43

9 IBM xSeries x3755 Red Hat RHEL [AMD−64] 3.0 U8 PCI Emulex: LP1050−E1, 2, 4, 39, LP1050Ex−E2, 4, 18, 39 ; FC−AL, EMC Y60
(8877) AS/ES v2.4.21−47.EL24, 25 Express, FC−SW CLARiiON
PCI−X IBM: 24P0960 (QLA2340)2, 7, 36, 43 , 24P8053 (QLA2342)2, 7, 43, AX100
39M5894 (QLA2460)2, 32, 43, 39M5895 (QLA2462)2, 32, 43;
QLogic: QLA2340−E−SP2, 7, 43, QLA2460−E−SP2, 32, 43,
QLE2360−E−SP2, 42, 43, QLE2460−E−SP2, 32, 43
10 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0 U8 PCI−X Emulex: LP101−E2, 4, 18, 39 , LP1050−E1, 2, 4, 39, LP982−E2, 4, 39; FC−AL, EMC Y
x4100, x4200 AS/ES v2.4.21−47.EL24, 25 FC−SW CLARiiON
QLogic: QLA200−E−SP2, 15, 43, QLA210−E−SP2, 15, 43, AX100
QLA2340−E−SP7, 43, QLE220−E−SP2, 55, 56
11 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0 U8 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y
AS/ES v2.4.21−47.EL24, 25 BL25p/BL45p 381881−B2140, 43, Emulex−based BL25/30/35/45p FC−SW CLARiiON
Fibre Channel Mezzanine HBA − 394588−B214, 39, 46, 47 AX100
12 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 3.0 U8 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.4.21−47.EL24, 25 HBA − 394588−B214, 39, 46, 47 FC−SW CLARiiON
AX100
13 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0 U8 PCI, Emulex: LP101−E2, 4, 18, 39 , LP1050−E1, 4, 39, LP982−E4, 39; FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.4.21−47.EL24, 25 PCI−X FC−SW CLARiiON
DL58521 HPQ AD167A/FC2143 (LP1150)2, 4, 39, 45 ; AX100
QLogic: QLA200−E−SP2, 15, 43, QLA210−E−SP2, 15, 43,
QLA2340−E−SP7, 43, QLE220−E−SP2, 55, 56
14 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: U4+ PCI−X HPQ Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC N6, 11
AS/ES v2.4.21−27.0.4.EL24, 64, U5 381881−B2140, 62, 63 FC−SW CLARiiON
AS/ES v2.4.21−32.EL24, 64, U5+ AX100
AS/ES v2.4.21−32.0.1.EL24, 64
15 IBM eServer 326m Red Hat RHEL [AMD−64] 3.0: U6 PCI Emulex: LP1050Ex−E2, 4, 18, 19 , LPe111−E2, 4, 13, 19 , LPe1150−E2, FC−AL, EMC Y6, 11
(Model 7969) AS/ES v2.4.21−37.EL, U6+ AS/ES Express, 4, 19, 33; FC−SW CLARiiON
v2.4.21−37.0.1.EL PCI−X AX100
QLogic: QLE2360−E−SP2, 10, 41, 42 , QLE2460−E−SP2, 10, 32
16 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0: U6 PCI−X Emulex: LP101−E2, 4, 18, 19 , LP1050−E1, 2, 4, 19, LP982−E2, 4, 19; FC−AL, EMC N6, 11
x4100, x4200 AS/ES v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL QLogic: QLA200−E−SP2, 10, 15, QLA210−E−SP2, 10, 15, AX100
QLA2340−E−SP7, 10
17 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: U6 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y6, 11
AS/ES v2.4.21−37.EL, U6+ AS/ES BL25p/BL45p 381881−B2110, 40, Emulex−based BL25/30/35/45p FC−SW CLARiiON
v2.4.21−37.0.1.EL Fibre Channel Mezzanine HBA − 394588−B214, 19, 46, 47 AX100
18 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 3.0: U6 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.4.21−37.EL, U6+ AS/ES HBA − 394588−B214, 19, 46, 47 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX100
19 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0: U6 PCI, Emulex: LP101−E2, 4, 18, 19 , LP1050−E1, 4, 19, LP982−E4, 19; FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.4.21−37.0.1.EL QLogic: QLA200−E−SP2, 10, 15, QLA210−E−SP2, 10, 15, AX100
QLA2340−E−SP7, 10
20 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0: U6 PCI, HPQ AD167A/FC2143 (LP1150)2, 4, 19, 45 FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.4.21−37.0.1.EL AX100
21 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0: U7 PCI QLogic QLE220−E−SP2, 29, 59 FC−AL, EMC Y
AS/ES v2.4.21−40.EL24, 25, U8 Express, FC−SW CLARiiON
AS/ES v2.4.21−47.EL24, 25 PCI−X AX100
22 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 PCI−X Emulex: LP1050−E1, 2, 4, 20, LP982−E2, 4, 20 FC−AL, EMC Y6, 11
AS/ES: v2.6.9−5.0.5.EL22, FC−SW CLARiiON
v2.6.9−5.EL22 AX100
23 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP101−E2, 4, 18, 20 , LP1050−E1, 4, 58, LP982−E4, 58 FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES: v2.6.9−5.0.5.EL22, PCI−X FC−SW CLARiiON
DL58521 v2.6.9−5.EL22 AX100
24 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP1050−E1, 2, 4, 20, LP982−E2, 4, 20 FC−AL, EMC Y6, 11
(Model 8835), 326 AS/ES: v2.6.9−5.0.5.EL22, PCI−X FC−SW CLARiiON
(Model 8848) v2.6.9−5.EL22 AX100
25 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 PCI−X QLogic QLA2340−E−SP2, 7, 23 FC−AL, EMC Y6, 11
AS/ES: v2.6.9−5.0.5.EL22, FC−SW CLARiiON
v2.6.9−5.EL22; AX100
Red Hat RHEL [AMD−64] 4.0 U1
AS/ES v2.6.9−11.EL22
26 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0 PCI, IBM 24P0960 (QLA2340)2, 7, 23, 36 ; FC−AL, EMC Y6, 11
(Model 8835), 326 AS/ES: v2.6.9−5.0.5.EL22, PCI−X QLogic QLA2340−E−SP2, 7, 23 FC−SW CLARiiON
(Model 8848) v2.6.9−5.EL22; AX100
Red Hat RHEL [AMD−64] 4.0 U1
AS/ES v2.6.9−11.EL22
27 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 PCI, QLogic: QLA200−E−SP2, 15, 23, QLA2340−E−SP7, 23 FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES: v2.6.9−5.0.5.EL22, PCI−X FC−SW CLARiiON
DL58521 v2.6.9−5.EL22; AX100
Red Hat RHEL [AMD−64] 4.0 U1
AS/ES v2.6.9−11.EL22

11/02/2006 121 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
28 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 U1 PCI−X Emulex: LP1050−E1, 2, 4, 44, LP982−E2, 4, 44 FC−AL, EMC Y6, 11
AS/ES v2.6.9−11.EL22 FC−SW CLARiiON
AX100
29 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 4.0 U1 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y6, 11
BL35p AS/ES v2.6.9−11.EL22 HBA − 394588−B214, 44, 46, 47 FC−SW CLARiiON
AX100
30 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 U1 PCI, Emulex: LP101−E2, 4, 18, 44 , LP1050−E1, 4, 44, LP982−E4, 44 FC−AL, EMC N6, 11
DL14521, DL38521, AS/ES v2.6.9−11.EL22 PCI−X FC−SW CLARiiON
DL58521 AX100
31 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0 U1 PCI, Emulex: LP1050−E1, 2, 4, 44, LP982−E2, 4, 44 FC−AL, EMC Y6, 11
(Model 8835), 326 AS/ES v2.6.9−11.EL22 PCI−X FC−SW CLARiiON
(Model 8848) AX100
32 IBM eServer 326m Red Hat RHEL [AMD−64] 4.0: U2 PCI Emulex: LP1050Ex−E2, 3, 4, 18, LPe111−E2, 3, 4, 13, LPe1150−E2, 3, FC−AL, EMC Y5, 6
(Model 7969) AS/ES v2.6.9−22.EL, U2+ AS/ES Express, 4, 33; FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X AX100
v2.6.9−22.0.2.EL QLogic: QLE2360−E−SP2, 8, 41, 42 , QLE2460−E−SP2, 8, 32
33 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: U2 PCI−X Emulex: LP1050−E1, 2, 3, 4, LP982−E2, 3, 4; FC−AL, EMC Y5, 6
x4100, x4200 AS/ES v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES QLogic QLA2340−E−SP2, 7, 8 AX100
v2.6.9−22.0.2.EL
34 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 4.0: U2 PCI−X HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y5, 6
AS/ES v2.6.9−22.EL, U2+ AS/ES HBA − 394588−B213, 4, 46, 47 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX100
v2.6.9−22.0.2.EL
35 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: U2 PCI−X QLogic QLA2460−E−SP2, 8, 32 FC−AL, EMC Y5, 6
AS/ES v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX100
v2.6.9−22.0.2.EL
36 HPQ Proliant BL25p Red Hat RHEL [AMD−64] 4.0: U2 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y5, 6
AS/ES v2.6.9−22.EL, U2+ AS/ES HBA − 394588−B213, 4, 46, 47 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX100
v2.6.9−22.0.2.EL
37 HPQ Proliant BL35p Red Hat RHEL [AMD−64] 4.0: U2 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y5, 6
AS/ES v2.6.9−22.EL, U2+ AS/ES HBA − 394588−B214, 46, 47 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX100
v2.6.9−22.0.2.EL
38 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: U2 PCI, Emulex: LP101−E2, 4, 18, 20 , LP101−E2, 4, 18, 44 , LP1050−E1, 4, 44, FC−AL, EMC Y5, 6
DL14521, DL38521, AS/ES v2.6.9−22.EL, U2+ AS/ES PCI−X LP1050−E1, 4, 58, LP982−E4, 44, LP982−E4, 58; FC−SW CLARiiON
DL58521 v2.6.9−22.0.1.EL, U2+ AS/ES AX100
v2.6.9−22.0.2.EL HPQ AD167A/FC2143 (LP1150)2, 3, 4, 45;
QLogic: QLA200−E−SP2, 15, QLA210−E−SP2, 8, 15
39 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: U2 PCI, Emulex: LP1050−E1, 2, 3, 4, LP982−E2, 3, 4; FC−AL, EMC Y5, 6
(Model 8835), 326 AS/ES v2.6.9−22.EL, U2+ AS/ES PCI−X FC−SW CLARiiON
(Model 8848) v2.6.9−22.0.1.EL, U2+ AS/ES IBM 24P0960 (QLA2340)2, 7, 8, 36 AX100
v2.6.9−22.0.2.EL
40 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: U2 PCI, QLogic QLA2340−E−SP2, 7, 8 FC−AL, EMC Y5, 6
Primergy RX800 S2; AS/ES v2.6.9−22.EL, U2+ AS/ES PCI−X FC−SW CLARiiON
IBM eServer: 325 v2.6.9−22.0.1.EL, U2+ AS/ES AX100
(Model 8835), 326 v2.6.9−22.0.2.EL
(Model 8848)
41 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: U2 PCI, QLogic QLA2340−E−SP7, 8 FC−AL, EMC Y5, 6
Primergy RX800 S2; AS/ES v2.6.9−22.EL, U2+ AS/ES PCI−X FC−SW CLARiiON
HPQ Proliant: v2.6.9−22.0.1.EL, U2+ AS/ES AX100
DL14521, DL38521, v2.6.9−22.0.2.EL
DL58521
42 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 4.0: U3 PCI Emulex: LP101−E2, 4, 14, 18 , LP1050−E1, 2, 4, 14, LP1050Ex−E2, 4, FC−AL, EMC Y
AS/ES v2.6.9−34.EL, U3+ AS/ES Express, 14, 18, LP982−E2, 4, 14, LPe111−E2, 4, 13, 14 , LPe1150−E2, 4, 14, 33 ; FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX100
v2.6.9−34.0.2.EL QLogic: QLA200−E−SP2, 15, 16, QLA210−E−SP2, 15, 16,
QLA2340−E−SP2, 7, 16, QLE220−E−SP2, 28, 29, QLE2360−E−SP2,
16, 41, 42 , QLE2460−E−SP2, 16, 32

43 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: U3 PCI−X Emulex: LP1050−E1, 2, 4, 14, LP982−E2, 4, 14; FC−AL, EMC Y
x4100, x4200 AS/ES v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA2340−E−SP2, 7, 16 AX100
v2.6.9−34.0.2.EL
44 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 4.0: U3 PCI−X HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
AS/ES v2.6.9−34.EL, U3+ AS/ES HBA − 394588−B214, 14, 46, 47 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL
45 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: U3 PCI−X QLogic QLA2460−E−SP2, 16, 32 FC−AL, EMC Y
AS/ES v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL
46 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 4.0: U3 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.6.9−34.EL, U3+ AS/ES HBA − 394588−B214, 14, 46, 47 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL
47 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: U3 PCI, Emulex: LP101−E2, 4, 14, 18 , LP1050−E1, 4, 14, LP982−E4, 14; FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.6.9−34.0.1.EL, U3+ AS/ES HPQ AD167A/FC2143 (LP1150)2, 4, 14, 45 ; AX100
v2.6.9−34.0.2.EL QLogic: QLA200−E−SP2, 15, 16, QLA210−E−SP2, 15, 16,
QLE220−E−SP2, 28, 29, 30
48 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: U3 PCI, Emulex: LP1050−E1, 2, 4, 14, LP982−E2, 4, 14; FC−AL, EMC Y
(Model 8835), 326 AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
(Model 8848) v2.6.9−34.0.1.EL, U3+ AS/ES IBM 24P0960 (QLA2340)2, 7, 16, 36 AX100
v2.6.9−34.0.2.EL
49 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: U3 PCI, QLogic QLA2340−E−SP2, 7, 16 FC−AL, EMC Y
Primergy RX800 S2; AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
IBM eServer: 325 v2.6.9−34.0.1.EL, U3+ AS/ES AX100
(Model 8835), 326 v2.6.9−34.0.2.EL
(Model 8848)

11/02/2006 122 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
50 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: U3 PCI, QLogic QLA2340−E−SP7, 16 FC−AL, EMC Y
Primergy RX800 S2; AS/ES v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
HPQ Proliant: v2.6.9−34.0.1.EL, U3+ AS/ES AX100
DL14521, DL38521, v2.6.9−34.0.2.EL
DL58521
51 IBM xSeries x3455 Red Hat RHEL [AMD−64] 4.0: U4 PCI Emulex: LP10000ExDC−E2, 4, 31, 61 , LP1050Ex−E2, 4, 18, 31 ; FC−AL, EMC Y
(7984) AS/ES v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
v2.6.9−42.0.2.EL IBM: 42C2069 (LPe11000)2, 4, 31, 57 , 42C2071 (LPe11002)2, 4, 31, AX100
33;

QLogic: QLE2360−E−SP2, 26, 54, QLE2460−E−SP2, 26, 53


52 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: U4 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y5, 6
(403433−B21), AS/ES v2.6.9−42.EL, U4+ AS/ES Express Bladesystem (403621−B21)13, 31, 49 FC−SW CLARiiON
(403434−B21), v2.6.9−42.0.2.EL AX100
(407234−B21),
(407235−B21)
53 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: U4 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y48
(403433−B21), AS/ES v2.6.9−42.EL, U4+ AS/ES Express Bladesystem (403621−B21)31, 49, 50 FC−SW CLARiiON
(403434−B21), v2.6.9−42.0.2.EL AX100
(407234−B21),
(407235−B21)
54 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: U4 PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), AS/ES v2.6.9−42.EL, U4+ AS/ES Express (403619−B21)26, 35 FC−SW CLARiiON
(403434−B21), v2.6.9−42.0.2.EL AX100
(407234−B21),
(407235−B21)
55 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: U4 PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y
(403433−B21), AS/ES v2.6.9−42.EL, U4+ AS/ES Express Bladesystem (403621−B21)31, 49, 50, QLogic QMH2462 4Gb FC FC−SW CLARiiON
(403434−B21), v2.6.9−42.0.2.EL HBA for HP c−Class Bladesystem (403619−B21)26, 35 AX100
(407234−B21),
(407235−B21)
56 Dell PowerEdge Red Hat RHEL [AMD−64] 4.0: U4 PCI Emulex LP1050−E1, 2, 4, 31; FC−AL, EMC Y
6950; AS/ES v2.6.9−42.EL, U4+ AS/ES Express, QLogic QLA2340−E−SP2, 7, 26 FC−SW CLARiiON
IBM xSeries x3755 v2.6.9−42.0.2.EL PCI−X AX100
(8877)
57 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 4.0: U4 PCI Emulex: LP101−E2, 4, 18, 31 , LP1050Ex−E2, 4, 18, 31 , LP982−E2, 4, FC−AL, EMC Y
AS/ES v2.6.9−42.EL, U4+ AS/ES Express, 31, LPe111−E2, 4, 13, 31 , LPe1150−E2, 4, 31, 33 ; FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX100
QLogic: QLA200−E−SP2, 15, 26, QLA210−E−SP2, 15, 26,
QLE220−E−SP2, 29, 51, QLE2360−E−SP2, 26, 41, 42 ,
QLE2460−E−SP2, 26, 32
58 IBM xSeries x3755 Red Hat RHEL [AMD−64] 4.0: U4 PCI IBM: 24P0960 (QLA2340)2, 7, 26, 36 , 24P8053 (QLA2342)2, 7, 26; FC−AL, EMC Y
(8877) AS/ES v2.6.9−42.EL, U4+ AS/ES Express, FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X QLogic: QLA2460−E−SP2, 26, 53, QLE2360−E−SP2, 26, 54, AX100
QLE2460−E−SP2, 26, 53
59 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: U4 PCI−X Emulex: LP1050−E1, 2, 4, 31, LP982−E2, 4, 31; FC−AL, EMC Y
x4100, x4200 AS/ES v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL QLogic QLA2340−E−SP2, 7, 26 AX100
60 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 4.0: U4 PCI−X HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
AS/ES v2.6.9−42.EL, U4+ AS/ES HBA − 394588−B214, 31, 46, 47 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX100
61 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: U4 PCI−X QLogic QLA2460−E−SP2, 26, 32 FC−AL, EMC Y
AS/ES v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX100
62 HPQ Proliant: BL25p, Red Hat RHEL [AMD−64] 4.0: U4 PCI−X52 HPQ Emulex−based BL25/30/35/45p Fibre Channel Mezzanine FC−AL, EMC Y
BL35p AS/ES v2.6.9−42.EL, U4+ AS/ES HBA − 394588−B214, 31, 46, 47 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX100
63 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: U4 PCI, Emulex: LP101−E2, 4, 18, 31 , LP1050−E1, 4, 31, LP982−E4, 31; FC−AL, EMC Y
DL14521, DL38521, AS/ES v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
DL58521 v2.6.9−42.0.2.EL HPQ AD167A/FC2143 (LP1150)2, 4, 31, 45 ; AX100
QLogic: QLA200−E−SP2, 15, 26, QLA210−E−SP2, 15, 26,
QLA2340−E−SP7, 26, QLE220−E−SP2, 29, 30, 51
64 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: U4 PCI, Emulex: LP1050−E1, 2, 4, 31, LP982−E2, 4, 31; FC−AL, EMC Y
(Model 8835), 326 AS/ES v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
(Model 8848) v2.6.9−42.0.2.EL IBM 24P0960 (QLA2340)2, 7, 26, 36 ; AX100
QLogic QLA2340−E−SP2, 7, 26
65 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0 U7 PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)2, 27, 37, FC−SW EMC Y
LS20 (Model 8850) AS/ES v2.4.21−40.EL24, 25 38, LP1005DC FC Exp Card2, 4, 17, 27 ; CLARiiON
AX100
IBM HS20 4GB SFF FC Exp Card: (26R0890)2, 9, (26R0890)2, 9, 10;
IBM HS20: 4GB Standard FC Exp Card (26R0884)2, 10, 12, FC Exp
Card (13N2203) for IBM eServer LS202, 7, 10, FC SFF Exp Card
(26K4841) for IBM eServer LS202, 7, 10
66 IBM BladeCenter: Red Hat RHEL [AMD−64] 3.0 U8 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)2, 37, 38, FC−SW EMC Y
LS20 (Model 8850), AS/ES v2.4.21−47.EL24, 25 39, HS20 4GB SFF FC Exp Card (26R0890)2, 9, 43, HS20 FC Exp CLARiiON
LS21 (Model 7971), Card (26K4841)2, 7, 43 AX100
LS41 (Model 7972)
67 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0 U8 PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, 17, 39 , HS20 4GB FC−SW EMC Y
LS20 (Model 8850) AS/ES v2.4.21−47.EL24, 25 Standard FC Exp Card (26R0884)2, 12, 43, HS20 FC Exp Card CLARiiON
(13N2203) for IBM eServer LS202, 7, 43, HS20 FC SFF Exp Card AX100
(26K4841) for IBM eServer LS202, 7, 43
68 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0: U6 PCI−X IBM HS20 4GB SFF FC Exp Card: (26R0890)2, 9, (26R0890)2, 9, 10; FC−SW EMC N6, 11
LS20 (Model 8850) AS/ES v2.4.21−37.EL, U6+ AS/ES CLARiiON
v2.4.21−37.0.1.EL IBM HS20 4GB Standard FC Exp Card (26R0884)2, 10, 12 AX100
69 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0: U6 PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, 17, 19 , HS20 FC Exp Card FC−SW EMC Y6, 11
LS20 (Model 8850) AS/ES v2.4.21−37.EL, U6+ AS/ES (13N2203) for IBM eServer LS202, 7, 10, HS20 FC SFF Exp Card CLARiiON
v2.4.21−37.0.1.EL (26K4841) for IBM eServer LS202, 7, 10 AX100

11/02/2006 123 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
70 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: U2 PCI−X IBM: Emulex LP1005DC FC Exp Card2, 3, 4, 17, HS20 4GB SFF FC FC−SW EMC Y5, 6
LS20 (Model 8850) AS/ES v2.6.9−22.EL, U2+ AS/ES Exp Card (26R0890)2, 9, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES (26R0884)2, 8, 12, HS20 FC Exp Card (13N2203) for IBM eServer AX100
v2.6.9−22.0.2.EL LS202, 7, 8, HS20 FC SFF Exp Card (26K4841) for IBM eServer
LS202, 7, 8
71 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: U3 PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)2, 14, 37, FC−SW EMC Y
LS20 (Model 8850) AS/ES v2.6.9−34.EL, U3+ AS/ES 38,LP1005DC FC Exp Card2, 4, 14, 17 ; CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX100
v2.6.9−34.0.2.EL IBM HS20 4GB: SFF FC Exp Card (26R0890)2, 9, 16, Standard FC
Exp Card (26R0884)2, 12, 16;
IBM HS20 FC: Exp Card (13N2203) for IBM eServer LS202, 7, 16,
SFF Exp Card (26K4841) for IBM eServer LS202, 7, 16
72 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: U4 PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)2, 31, 37, FC−SW EMC Y
LS20 (Model 8850) AS/ES v2.6.9−42.EL, U4+ AS/ES 38, LP1005DC FC Exp Card2, 4, 17, 31 ; CLARiiON
v2.6.9−42.0.2.EL AX100
IBM HS20 4GB: SFF FC Exp Card (26R0890)2, 9, 26, Standard FC
Exp Card (26R0884)2, 12, 26;
IBM HS20 FC Exp Card: (13N2203) for IBM eServer LS202, 7, 26,
(26K4841)2, 7, 26;
IBM HS20 FC SFF Exp Card (26K4841) for IBM eServer LS202, 7,
26

1. Firmware Version 1.91a5


2. SNIA HBA API Supported.
3. Driver Version 8.0.16.17 Driver is integrated into the kernel.
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
6. VxVM is not supported on servers booting from the array.
7. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. BIOS 1.12
10. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Booting from the SAN with PowerPath is not supported.
12. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
14. Driver Version 8.0.16.18 Driver is integrated into the kernel.
15. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
17. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
18. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
19. Driver Version 7.3.2 Driver is integrated into the kernel.
20. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
21. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
22. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
23. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
25. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
26. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
27. Driver Version 7.3.3 Driver is integrated into the kernel.
28. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
29. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
30. Driver/BIOS are available at http://www.qlogic.com
31. Driver Version 8.0.16.27 Driver is integrated into the kernel.
32. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. Firmware Version 2.50a6
34. Driver Version 7.07.00
35. BIOS 1.16
36. This HBA is equivalent to the QLogic QLA2340.
37. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
38. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
39. Driver Version 7.3.6 Driver is integrated into the kernel.
40. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
41. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
42. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
43. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
44. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
45. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
46. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
47. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
48. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
49. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
50. Firmware Version 2.50a8
51. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
52. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
53. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
54. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
55. BIOS 1.02
56. Driver Version 7.07.05
57. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
58. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
59. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
60. PowerPath is not supported.
61. Firmware Version 1.91.a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
62. Driver Version 7.01.01 Driver is integrated into the kernel.
63. Driver Version 7.03.00 QLogic driver obtained from http://www.qlogic.com
64. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file names
must be used.

11/02/2006 124 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI Fujitsu Siemens BX600−FC22Q2, 9, 11, 27 FC−AL, EMC Y
BX620: S2F46, S246 26 FC−SW CLARiiON
AX100
2 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI Emulex LP1050Ex−E2, 4, 7, 45; FC−AL, EMC Y
1850, 1950, 2800, 2850; 26 Express QLogic QLE2360−E−SP2, 27, 42, 43 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
3 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI Emulex: LPe111−E2, 4, 39, 45 , LPe1150−E2, FC−AL, EMC Y
1850, 1950, 2800, 2850; 26 Express 4, 41, 45 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
4 HPQ Proliant: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4, FC−AL, EMC Y
DL360(G4)30, 26 Express 45, AD167A/FC2143 (LP1150)2, 4, 29, 45 FC−SW CLARiiON
DL380(G4)30, AX100
DL580(G3)30,
ML350(G4)30,
ML370(G4)30
5 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI QLogic QLE2460−E−SP2, 27, 53 FC−AL, EMC Y
1850, 1950, 2800, 2850; 26 Express FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
6 IBM xSeries: x3550 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI Emulex LP1050−E2, 4, 8, 45; FC−AL, EMC Y65
(7978), x3650 (7979) 26 Express, IBM: 24P0960 (QLA2340)2, 9, 27, 73 , FC−SW CLARiiON
PCI−X 24P8053 (QLA2342)2, 9, 27, 39M5894 AX100
(QLA2460)2, 27, 53, 39M5895 (QLA2462)2,
27, 53;

QLogic: QLA2340−E−SP2, 9, 27,


QLA2460−E−SP2, 27, 53, QLE2360−E−SP2,
27, 43, QLE2460−E−SP2, 27, 53

7 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI Emulex: LP101−E2, 4, 7, 45, LP1050−E2, 4, 8, FC−AL, EMC Y
2950; 26 Express, 45, LP1050Ex−E2, 4, 7, 45, LP982−E2, 4, 45, FC−SW CLARiiON
PCI−X LPe111−E2, 4, 39, 45 , LPe1150−E2, 4, 41, 45 ; AX100
Digital Henge Revo:
AS1500, AS1550, QLogic: QLA200−E−SP2, 6, 44,
AS2500; QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27,
QLE2360−E−SP2, 27, 42, 43 ,
Intel: SR1500/S5000PAL, QLE2460−E−SP2, 27, 53
SR2500/S5000PAL
8 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Dell 2342M9, 27 FC−AL, EMC Y
Unisys ES3105 26 FC−SW CLARiiON
AX100
9 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Dell: LPe1105−M2, 4, 41, 45 , QME24622, 27, FC−AL, EMC Y
26 56 FC−SW CLARiiON
AX100

11/02/2006 125 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
10 Fujitsu Siemens Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Emulex LP1050−E2, 4, 35, 45 FC−AL, EMC Y
Primergy: RX200 S2, 26 FC−SW CLARiiON
RX300 S2, TX200 S2, AX100
TX300 S2
11 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Emulex LP982−E2, 4, 45 FC−AL, EMC Y
1850, 2600, 2650, 2850; 26 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
12 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X Emulex: LP101−E2, 4, 7, 45, LP1050−E2, 4, 8, FC−AL, EMC Y
1850, 1950, 2600, 2650, 26 45; FC−SW CLARiiON
2850; AX100
QLogic: QLA200−E−SP2, 6, 44,
Digital Henge INNO: QLA2340−E−SP2, 9, 27
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
13 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y18, 19
(416653−B21), 26 HP c−Class Bladesystem (403621−B21)39, FC−SW CLARiiON
(416654−B21), 45, 84 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
14 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416653−B21), 26 HP c−Class Bladesystem (403619−B21)27, FC−SW CLARiiON
(416654−B21), 82 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
15 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X NEC N8190−120 (LP1050)4, 7, 16, 45 FC−AL, EMC Y
120Lh, 120Re−1, 26 FC−SW CLARiiON
120Rf−1, 120Rg−2, AX100
120Rh−2, 140He,
140Rd−4
16 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X NEC N8190−127 (LPe1150)1, 4, 16, 45 FC−AL, EMC Y
140He, 140Rd−4 26 FC−SW CLARiiON
AX100
17 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X QLogic QLA210−E−SP2, 6, 27 FC−AL, EMC Y
1850, 2600, 2650, 2850; 26 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230

11/02/2006 126 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
18 Digital Henge INNO: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X QLogic QLE220−E−SP2, 32, 76, 77 FC−AL, EMC Y
HR−4850, HR−6850; 26 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
19 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X22 QLogic: QLA210−E−SP2, 6, 27, FC−AL, EMC Y
(8865)20, 21, 26 QLE220−E−SP2, 32, 76, 77 FC−SW CLARiiON
x3950/x3950E/x460 AX100
(8872, 8874)20, 21
20 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X31 Emulex: LP101−E2, 4, 7, 45, LP1050−E2, 4, 8, FC−AL, EMC Y
JS1400, JS2400 26 45, LP982−E2, 4, 45; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27,
QLE220−E−SP2, 32, 76, 77
21 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI, PCI Dell: LPe1105−M2, 4, 41, 45 , QME24622, 27, FC−AL, EMC Y
26 Express, 56 FC−SW CLARiiON
PCI−X AX100
22 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI, Emulex: LP101−E2, 4, 7, 45, LP1050−E2, 4, 8, FC−AL, EMC Y
Samsung: ES470, 26 PCI−X 45, LP982−E2, 4, 45; FC−SW CLARiiON
ES570, SS140 AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27
23 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI, QLogic QLA2340−E−SP2, 9, 27 FC−AL, EMC Y
Samsung: ES570, SS140 26 PCI−X FC−SW CLARiiON
AX100
24 Samsung ES470 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI, QLogic QLA2340−E−SP2, 9, 44 FC−AL, EMC Y
26 PCI−X FC−SW CLARiiON
AX100
25 Samsung: ES470, Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI, QLogic QLE220−E−SP2, 32, 76, 77 FC−AL, EMC Y
ES570, SS140 26 PCI−X FC−SW CLARiiON
AX100
26 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI Emulex LP1050Ex−E2, 4, 7, 40; FC−AL, EMC Y
1850, 1950, 2800, 2850; 26 Express QLogic QLE2360−E−SP2, 43, 72 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
27 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI Emulex: LPe111−E2, 4, 39, 40 , LPe1150−E2, FC−AL, EMC Y
1850, 1950, 2800, 2850; 26 Express 4, 40, 41 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
28 HPQ Proliant: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4, FC−AL, EMC Y
DL360(G4)30, 26 Express 40, AD167A/FC2143 (LP1150)2, 4, 29, 40 FC−SW CLARiiON
DL380(G4)30, AX100
DL580(G3)30,
ML350(G4)30,
ML370(G4)30

11/02/2006 127 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
29 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI QLogic QLE2460−E−SP2, 53, 72 FC−AL, EMC Y
1850, 1950, 2800, 2850; 26 Express FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
30 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI Emulex: LP101−E2, 4, 7, 40, LP1050−E2, 4, 8, FC−AL, EMC Y
2950; 26 Express, 40, LP1050Ex−E2, 4, 7, 40, LP982−E2, 4, 40, FC−SW CLARiiON
PCI−X LPe111−E2, 4, 39, 40 , LPe1150−E2, 4, 40, 41 ; AX100
Digital Henge Revo:
AS1500, AS1550, QLogic: QLA200−E−SP2, 6, 72,
AS2500; QLA210−E−SP2, 6, 72, QLA2340−E−SP2, 9,
72,
QLE2360−E−SP2, 43, 72,
Intel: SR1500/S5000PAL, QLE2460−E−SP2, 53, 72
SR2500/S5000PAL
31 IBM xSeries: x3550 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI Emulex: LP1050−E2, 4, 8, 40, LP1050Ex−E2, FC−AL, EMC Y65
(7978), x3650 (7979) 26 Express, 4, 7, 40; FC−SW CLARiiON
PCI−X AX100
IBM: 24P0960 (QLA2340)2, 9, 72, 73 ,
24P8053 (QLA2342)2, 9, 72, 39M5894
(QLA2460)2, 53, 72, 39M5895 (QLA2462)2,
53, 72;

QLogic: QLA2340−E−SP2, 9, 72,


QLA2460−E−SP2, 53, 72, QLE2360−E−SP2,
43, 72, QLE2460−E−SP2, 53, 72

32 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI NEC: N8190−120 (LP1050)8, 16, 40, 75 , FC−AL, EMC Y
120Li, 120Rg−1, 26 Express, N8190−127 (LPe1150)16, 40, 41, 75 FC−SW CLARiiON
120Ri−2, 140Hf, PCI−X AX100
140Re−4
33 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Dell 2342M9, 72 FC−AL, EMC Y
Unisys ES3105 26 FC−SW CLARiiON
AX100
34 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Dell: LPe1105−M2, 4, 40, 41 , QME24622, 56, FC−AL, EMC Y
26 72 FC−SW CLARiiON
AX100
35 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Emulex LP982−E2, 4, 40 FC−AL, EMC Y
1850, 2600, 2650, 2850; 26 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
36 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X Emulex: LP101−E2, 4, 7, 40, LP1050−E2, 4, 8, FC−AL, EMC Y
1850, 1950, 2600, 2650, 26 40; FC−SW CLARiiON
2850; AX100
QLogic: QLA200−E−SP2, 6, 72,
Digital Henge INNO: QLA2340−E−SP2, 9, 72
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
37 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y18, 19
(416653−B21), 26 HP c−Class Bladesystem (403621−B21)39, FC−SW CLARiiON
(416654−B21), 40, 84 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)

11/02/2006 128 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
38 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416653−B21), 26 HP c−Class Bladesystem (403619−B21)72, FC−SW CLARiiON
(416654−B21), 82 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
39 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X NEC N8190−120 (LP1050)4, 7, 16, 40 FC−AL, EMC Y
120Lh, 120Re−1, 26 FC−SW CLARiiON
120Rf−1, 120Rg−2, AX100
120Rh−2, 140He,
140Rd−4
40 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X NEC N8190−127 (LPe1150)1, 4, 16, 40 FC−AL, EMC Y
140He, 140Rd−4 26 FC−SW CLARiiON
AX100
41 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X QLogic QLA210−E−SP2, 6, 72 FC−AL, EMC Y
1850, 2600, 2650, 2850; 26 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
42 Digital Henge INNO: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X QLogic QLE220−E−SP2, 76, 77 FC−AL, EMC Y
HR−4850, HR−6850; 26 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
43 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X22 QLogic: QLA210−E−SP2, 6, 72, FC−AL, EMC Y
(8865)20, 21, 26 QLE220−E−SP2, 76, 77 FC−SW CLARiiON
x3950/x3950E/x460 AX100
(8872, 8874)20, 21
44 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X31 Emulex: LP101−E2, 4, 7, 40, LP1050−E2, 4, 8, FC−AL, EMC Y
JS1400, JS2400 26 40, LP982−E2, 4, 40; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP2, 6, 72,
QLA210−E−SP2, 6, 72, QLA2340−E−SP2, 9,
72, QLE220−E−SP2, 76, 77

45 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, PCI Dell: LPe1105−M2, 4, 40, 41 , QME24622, 56, FC−AL, EMC Y
26 Express, 72 FC−SW CLARiiON
PCI−X AX100
46 HPQ Proliant: Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, PCI Emulex: LPe111−E2, 4, 39, 40 , LPe1150−E2, FC−AL, EMC Y
DL380(G5), DL580(G4) 26 Express, 4, 40, 41; FC−SW CLARiiON
PCI−X AX100
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4,
40, AD167A/FC2143 (LP1150)2, 4, 29, 40 ,
AE311A/FC1142SR (QLE2460)2, 53, 72,
AE312A/FC1242SR (QLE2462)2, 53, 72
47 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, Emulex: LP101−E2, 4, 7, 40, LP1050−E2, 4, 8, FC−AL, EMC Y
Samsung: ES470, 26 PCI−X 40, LP982−E2, 4, 40; FC−SW CLARiiON
ES570, SS140 AX100
QLogic: QLA200−E−SP2, 6, 72,
QLA210−E−SP2, 6, 72, QLA2340−E−SP2, 9,
72

48 Samsung: ES470, Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI, QLogic QLE220−E−SP2, 76, 77 FC−AL, EMC Y
ES570, SS140 26 PCI−X FC−SW CLARiiON
AX100
49 NEC Express 5800 Red Hat RHEL [EM64T] 3.0: U3 AS/ES PCI NEC N8190−120 (LP1050)4, 7, 16, 81 FC−AL, EMC N19, 48
110Rg−1 v2.4.21−20.EL25, U4 AS/ES v2.4.21−27.EL25, 62, U4+ Express, FC−SW CLARiiON
AS/ES v2.4.21−27.0.1.EL25, 62, U4+ AS/ES PCI−X AX100
v2.4.21−27.0.2.EL25, 62, U4+ AS/ES
v2.4.21−27.0.4.EL25, 62

11/02/2006 129 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
50 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U3 AS/ES PCI−X NEC N8190−120: (LP1050)4, 7, 16, 61 , FC−AL, EMC N19, 48
120Lh, 120Re−1, v2.4.21−20.EL25, U4 AS/ES v2.4.21−27.EL25, 62, U4+ (LP1050)4, 7, 16, 63, 64 FC−SW CLARiiON
120Rf−1, 120Rg−2, AS/ES v2.4.21−27.0.1.EL25, 62, U4+ AS/ES AX100
120Rh−2 v2.4.21−27.0.2.EL25, 62, U4+ AS/ES
v2.4.21−27.0.4.EL25, 62, U5 AS/ES v2.4.21−32.EL25, 62,
U5+ AS/ES v2.4.21−32.0.1.EL25, 62
51 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U4 AS/ES PCI Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC N19, 48
1850, 2800, 2850 v2.4.21−27.EL25, 62, U4+ AS/ES v2.4.21−27.0.1.EL25, Express 71, LP982−E2, 4, 71; FC−SW CLARiiON
62,U4+ AS/ES v2.4.21−27.0.2.EL25, 62, U4+ AS/ES AX100
v2.4.21−27.0.4.EL25, 62 QLogic: QLA200−E−SP2, 6, 93,
QLA2340−E−SP2, 9, 70, QLE2360−E−SP2,
42, 43, 70

52 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U4 AS/ES PCI−X Dell 2342M9, 92 FC−AL, EMC N19, 48
v2.4.21−27.EL25, 62, U4+ AS/ES v2.4.21−27.0.1.EL25, FC−SW CLARiiON
62,U4+ AS/ES v2.4.21−27.0.2.EL25, 62, U4+ AS/ES AX100
v2.4.21−27.0.4.EL25, 62, U5 AS/ES v2.4.21−32.EL25, 62,
U5+ AS/ES v2.4.21−32.0.1.EL25, 62
53 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI NEC N8190−120: (LP1050)4, 7, 16, 61 , FC−AL, EMC N19, 48
120Rd−1, 140Hd, v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, (LP1050)4, 7, 16, 63, 64 FC−SW CLARiiON
140Rc−4, 180Rd−4 62 AX100
54 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex LP1050Ex−E2, 4, 7, 57; FC−AL, EMC Y19, 48
1850, 2800, 2850; v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, Express QLogic QLE2360−E−SP2, 27, 42, 43 FC−SW CLARiiON
62 AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
55 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
1850, 2800, 2850; v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, Express, 71; FC−SW CLARiiON
62 PCI−X AX100
LangChao: NC3000, QLogic QLA200−E−SP2, 6, 69, 70
NC3500, NF500, NF520
56 Dell PowerEdge: 2600, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
2650; v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, 71; FC−SW CLARiiON
62 AX100
Digital Henge SH4500R4; QLogic QLA200−E−SP2, 6, 69, 70
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS370,
SS3840, ZSS150,
ZSS230
57 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X22 Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
(8865)20, 21, v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, 71; FC−SW CLARiiON
x3950/x3950E/x460 62 AX100
(8872, 8874)20, 21 QLogic QLA200−E−SP2, 6, 69, 70
58 Samsung: ES470, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI, Emulex: LP101−E2, 4, 7, 71, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
ES570, SS140 v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, PCI−X 71; FC−SW CLARiiON
62 AX100
QLogic QLA200−E−SP2, 6, 69, 70
59 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI Fujitsu Siemens BX600−FC22Q2, 9, 11, 27 FC−AL, EMC N19, 48
BX620: S2F46, S246 U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
60 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI Emulex LP1050Ex−E2, 4, 7, 57; FC−AL, EMC Y19, 48
1850, 1950, 2800, 2850; U6+ AS/ES v2.4.21−37.0.1.EL Express QLogic QLE2360−E−SP2, 27, 42, 43 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230

11/02/2006 130 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
61 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI Emulex: LPe111−E2, 4, 39, 57 , LPe1150−E2, FC−AL, EMC Y19, 48
1850, 1950, 2800, 2850; U6+ AS/ES v2.4.21−37.0.1.EL Express 4, 41, 57 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
62 HPQ Proliant: Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4, FC−AL, EMC Y19, 48
DL360(G4)30, U6+ AS/ES v2.4.21−37.0.1.EL Express 57, AD167A/FC2143 (LP1150)2, 4, 29, 57 FC−SW CLARiiON
DL380(G4)30, AX100
DL580(G3)30,
ML350(G4)30,
ML370(G4)30
63 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI QLogic QLE2460−E−SP2, 27, 53 FC−AL, EMC Y19, 48
1850, 1950, 2800, 2850; U6+ AS/ES v2.4.21−37.0.1.EL Express FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
64 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
2950 U6+ AS/ES v2.4.21−37.0.1.EL Express, 57, LP1050Ex−E2, 4, 7, 57, LP982−E2, 4, 57, FC−SW CLARiiON
PCI−X LPe111−E2, 4, 39, 57 , LPe1150−E2, 4, 41, 57 ; AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27,
QLE2360−E−SP2, 27, 42, 43 ,
QLE2460−E−SP2, 27, 53
65 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X Dell 2342M9, 27 FC−AL, EMC N19, 48
Unisys ES3105 U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX100
66 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X Dell: LPe1105−M2, 4, 41, 57 , QME24622, 27, FC−AL, EMC N19, 48
U6+ AS/ES v2.4.21−37.0.1.EL 56 FC−SW CLARiiON
AX100
67 Fujitsu Siemens Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X Emulex LP1050−E2, 4, 35, 57 FC−AL, EMC Y19, 48
Primergy: RX200 S2, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
RX300 S2, TX200 S2, AX100
TX300 S2
68 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X Emulex LP982−E2, 4, 57; FC−AL, EMC Y19, 48
1850, 2600, 2650, 2850; U6+ AS/ES v2.4.21−37.0.1.EL QLogic QLA210−E−SP2, 6, 27 FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230

11/02/2006 131 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
69 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
1850, 1950, 2600, 2650, U6+ AS/ES v2.4.21−37.0.1.EL 57; FC−SW CLARiiON
2850; AX100
QLogic: QLA200−E−SP2, 6, 44,
Digital Henge INNO: QLA2340−E−SP2, 9, 27
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, ZSS150, ZSS230
70 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X NEC N8190−120 (LP1050)4, 7, 16, 87 FC−AL, EMC N19, 48
120Lh, 120Re−1, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
120Rf−1, 120Rg−2, AX100
120Rh−2
71 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X NEC: N8190−120 (LP1050)4, 7, 16, 57 , FC−AL, EMC N19, 48
140He, 140Rd−4 U6+ AS/ES v2.4.21−37.0.1.EL N8190−127 (LPe1150)1, 4, 16, 57 FC−SW CLARiiON
AX100
72 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X22 Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
(8865)20, 21, U6+ AS/ES v2.4.21−37.0.1.EL 57, LP982−E2, 4, 57; FC−SW CLARiiON
x3950/x3950E/x460 AX100
(8872, 8874)20, 21 QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27

73 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X31 Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
JS1400, JS2400 U6+ AS/ES v2.4.21−37.0.1.EL 57, LP982−E2, 4, 57; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27, QLA2340−E−SP2, 9,
27

74 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, PCI Dell: LPe1105−M2, 4, 41, 57 , QME24622, 27, FC−AL, EMC N19, 48
U6+ AS/ES v2.4.21−37.0.1.EL Express, 56 FC−SW CLARiiON
PCI−X AX100
75 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, Emulex: LP101−E2, 4, 7, 57, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
Samsung: ES470, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X 57, LP982−E2, 4, 57; FC−SW CLARiiON
ES570, SS140 AX100
QLogic: QLA200−E−SP2, 6, 44,
QLA210−E−SP2, 6, 27
76 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, QLogic QLA2340−E−SP2, 9, 27 FC−AL, EMC Y19, 48
Samsung: ES570, SS140 U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
77 Samsung ES470 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI, QLogic QLA2340−E−SP2, 9, 44 FC−AL, EMC Y19, 48
U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX100
78 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP2, 33, 54 FC−AL, EMC Y
v2.4.21−40.EL25, 26, U8 AS/ES v2.4.21−47.EL25, 26 Express FC−SW CLARiiON
AX100
79 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP2, 33, 54 FC−AL, EMC Y
1900, 2850, 2900, 2950; v2.4.21−40.EL25, 26, U8 AS/ES v2.4.21−47.EL25, 26 Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
80 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP2, 33, 54 FC−AL, EMC Y
2800 v2.4.21−40.EL25, 26, U8 AS/ES v2.4.21−47.EL25, 26 Express, FC−SW CLARiiON
PCI−X AX100
81 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.0.5.EL49 PCI−X Emulex LP101−E2, 4, 7, 80 FC−AL, EMC N19, 48
HPQ Proliant FC−SW CLARiiON
DL360(G4)30; AX100
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003
82 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.0.5.EL49 PCI−X QLogic QLA200−E−SP2, 6, 50 FC−AL, EMC N19, 48
Fujitsu Siemens FC−SW CLARiiON
Primergy: RX200 S2, AX100
RX300, RX300 S2,
RX600 S2, TX200 S2,
TX300, TX300 S2, TX600
S2;
HPQ Proliant
DL360(G4)30;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003

11/02/2006 132 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
83 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.0.5.EL49 PCI−X QLogic QLA2340−E−SP2, 9, 50 FC−AL, EMC N19, 48
Primergy: RX200 S2, FC−SW CLARiiON
RX600 S2, TX600 S2 AX100
84 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.EL49 PCI−X Emulex LP101−E2, 4, 7, 80 FC−AL, EMC N19, 48
HPQ Proliant FC−SW CLARiiON
DL360(G4)30; AX100
IBM xSeries x3850/x366
(8863)20, 21;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003
85 IBM xSeries x3850/x366 Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.EL49 PCI−X Emulex: LP1050−E2, 4, 8, 89, LP982−E2, 4, FC−AL, EMC Y
(8863)20, 21 89 FC−SW CLARiiON
AX100
86 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.EL49 PCI−X QLogic QLA200−E−SP2, 6, 50 FC−AL, EMC N19, 48
Fujitsu Siemens FC−SW CLARiiON
Primergy: RX200 S2, AX100
RX300, RX300 S2,
RX600 S2, TX200 S2,
TX300, TX300 S2, TX600
S2;
HPQ Proliant
DL360(G4)30;
IBM xSeries x3850/x366
(8863)20, 21;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003
87 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.EL49 PCI−X QLogic QLA2340−E−SP2, 9, 50 FC−AL, EMC N19, 48
Primergy: RX200 S2, FC−SW CLARiiON
RX600 S2, TX600 S2; AX100
IBM xSeries x3850/x366
(8863)20, 21
88 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.EL49 PCI−X22 Emulex LP101−E2, 4, 7, 80; FC−AL, EMC N19, 48
(8865)20, 21, QLogic: QLA200−E−SP2, 6, 50, FC−SW CLARiiON
x3950/x3950E/x460 QLA2340−E−SP2, 9, 50 AX100
(8872, 8874)20, 21
89 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0 AS/ES v2.6.9−5.EL49 PCI−X22 Emulex: LP1050−E2, 4, 8, 89, LP982−E2, 4, FC−AL, EMC Y
(8865)20, 21, 89 FC−SW CLARiiON
x3950/x3950E/x460 AX100
(8872, 8874)20, 21
90 Dell PowerEdge: 6800, Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI Emulex LP1050Ex−E2, 4, 7, 58 FC−AL, EMC Y
6850; v2.6.9−5.EL49 Express FC−SW CLARiiON
AX100
Digital Henge Revo:
JS1400, JS2400
91 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI Emulex: LP101−E2, 4, 7, 80, LP1050−E2, 4, 8, FC−AL, EMC N19, 48
1850, 2800, 2850 v2.6.9−5.EL49 Express 58, LP982−E2, 4, 58; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP2, 6, 50,
QLA2340−E−SP2, 9, 50
92 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI QLogic QLE2360−E−SP2, 42, 43, 50 FC−AL, EMC N19, 48
1850, 2800, 2850, 6800, v2.6.9−5.EL49 Express FC−SW CLARiiON
6850; AX100
Digital Henge Revo:
JS1400, JS2400
93 Dell PowerEdge: 6800, Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI Emulex LP101−E2, 4, 7, 80; FC−AL, EMC N19, 48
6850; v2.6.9−5.EL49 Express, QLogic QLA200−E−SP2, 6, 50 FC−SW CLARiiON
PCI−X AX100
HPQ Proliant
ML350(G4)30
94 Dell PowerEdge: 6800, Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI Emulex: LP1050−E2, 4, 8, 58, LP982−E2, 4, FC−AL, EMC N19, 48
6850 v2.6.9−5.EL49 Express, 58; FC−SW CLARiiON
PCI−X AX100
QLogic QLA2340−E−SP2, 9, 50
95 HPQ Proliant Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI Emulex: LP1050−E4, 8, 58, LP982−E4, 58 FC−AL, EMC N19, 48
ML350(G4)30 v2.6.9−5.EL49 Express, FC−SW CLARiiON
PCI−X AX100
96 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI Emulex: LP101−E2, 4, 7, 80, LP1050−E4, 8, FC−AL, EMC N19, 48
JS1400, JS2400 v2.6.9−5.EL49 Express, 58, LP982−E4, 58; FC−SW CLARiiON
PCI−X31 AX100
QLogic: QLA200−E−SP2, 6, 50,
QLA2340−E−SP9, 50
97 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI−X Emulex LP101−E2, 4, 35, 80 FC−AL, EMC N19, 48
Primergy: RX200 S2, v2.6.9−5.EL49 FC−SW CLARiiON
RX300, RX300 S2, AX100
RX600 S2, TX200 S2,
TX300, TX300 S2, TX600
S2

11/02/2006 133 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
98 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI−X Emulex LP1050Ex−E2, 4, 35, 58 FC−AL, EMC Y
Primergy: RX200 S2, v2.6.9−5.EL49 FC−SW CLARiiON
RX600 S2, TX600 S2 AX100
99 HPQ Proliant Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI−X Emulex: LP1050−E4, 8, 58, LP982−E4, 58 FC−AL, EMC N19, 48
DL360(G4)30 v2.6.9−5.EL49 FC−SW CLARiiON
AX100
100 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI−X QLogic QLA2340−E−SP9, 50 FC−AL, EMC N19, 48
Fujitsu Siemens v2.6.9−5.EL49 FC−SW CLARiiON
Primergy: RX200 S2, AX100
RX300, RX300 S2,
RX600 S2, TX200 S2,
TX300, TX300 S2, TX600
S2;
HPQ Proliant
DL360(G4)30;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer T630
6003
101 HPQ Proliant: Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI, Emulex: LP101−E2, 4, 7, 80, LP1050−E4, 8, FC−AL, EMC N19, 48
DL380(G4)30, v2.6.9−5.EL49 PCI−X 58, LP982−E4, 58 FC−SW CLARiiON
ML370(G4)30 AX100
102 HPQ Proliant Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI QLogic QLA2340−E−SP9, 50 FC−AL, EMC N19, 48
ML350(G4)30 v2.6.9−5.EL49; Express, FC−SW CLARiiON
PCI−X AX100
Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49
103 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI−X Dell 2342M9, 50 FC−AL, EMC N19, 48
v2.6.9−5.EL49; FC−SW CLARiiON
AX100
Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49
104 HPQ Proliant: Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL49, PCI, QLogic: QLA200−E−SP2, 6, 50, FC−AL, EMC N19, 48
DL380(G4)30, v2.6.9−5.EL49; PCI−X QLA2340−E−SP9, 50 FC−SW CLARiiON
ML370(G4)30 AX100
Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49
105 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI Emulex LP1050Ex−E2, 4, 7, 51 FC−AL, EMC Y
1850, 2800, 2850, 6800, Express FC−SW CLARiiON
6850; AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
106 Dell PowerEdge 2850 Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI QLogic QLA200−E−SP2, 6, 50, 55 FC−AL, EMC Y, Y19,
Express FC−SW CLARiiON 48
AX100
107 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI QLogic QLE2360−E−SP2, 42, 43, 50 FC−AL, EMC Y19, 48
1850, 2800, 2850, 6800, Express FC−SW CLARiiON
6850; AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
108 HPQ Proliant Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI Emulex: LP101−E2, 4, 7, 51, LP1050−E4, 8, FC−AL, EMC N19, 48
ML350(G4)30 Express, 51, LP982−E4, 51; FC−SW CLARiiON
PCI−X AX100
QLogic QLA200−E−SP2, 6, 50
109 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X Emulex LP101−E2, 4, 35, 51 FC−AL, EMC N19, 48
Primergy: RX200 S2, FC−SW CLARiiON
RX300, RX300 S2, AX100
TX200 S2, TX300, TX300
S2
110 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X Emulex LP1050Ex−E2, 4, 35, 51 FC−AL, EMC Y
Primergy: RX200 S2, FC−SW CLARiiON
RX600 S2, TX600 S2 AX100

11/02/2006 134 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
111 Dell PowerEdge: 6800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X Emulex: LP101−E2, 4, 7, 51, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
6850; 51, LP982−E2, 4, 51; FC−SW CLARiiON
AX100
Digital Henge INNO: QLogic QLA2340−E−SP2, 9, 50
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840,
ZSS150, ZSS230
112 HPQ Proliant Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X Emulex: LP101−E2, 4, 7, 51, LP1050−E4, 8, FC−AL, EMC N19, 48
DL360(G4)30 51, LP982−E4, 51 FC−SW CLARiiON
AX100
113 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X QLogic: QLA200−E−SP2, 6, 50, FC−AL, EMC N19, 48
Primergy: RX200 S2, QLA2340−E−SP9, 50 FC−SW CLARiiON
RX300, RX300 S2, AX100
TX200 S2, TX300, TX300
S2;
HPQ Proliant
DL360(G4)30
114 HPQ Proliant BL20p (G3) Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X12 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y
Channel Mezzanine HBA − 394757−B214, FC−SW CLARiiON
13, 15, 51 AX100
115 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X22 Emulex: LP101−E2, 4, 7, 51, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
(8865)20, 21, 51, LP982−E2, 4, 51; FC−SW CLARiiON
x3950/x3950E/x460 AX100
(8872, 8874)20, 21 QLogic QLA2340−E−SP2, 9, 50
116 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI−X31 Emulex: LP101−E2, 4, 7, 51, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
JS1400, JS2400 51, LP982−E2, 4, 51; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP2, 9, 50
117 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI, Emulex: LP101−E2, 4, 7, 51, LP1050−E2, 4, 8, FC−AL, EMC Y19, 48
1850, 2600, 2650, 2800, PCI−X 51, LP982−E2, 4, 51; FC−SW CLARiiON
2850; AX100
QLogic QLA2340−E−SP2, 9, 50
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470,
ES570, SS140
118 HPQ Proliant: Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI, Emulex: LP101−E2, 4, 7, 51, LP1050−E4, 8, FC−AL, EMC N19, 48
DL380(G4)30, PCI−X 51, LP982−E4, 51 FC−SW CLARiiON
ML370(G4)30 AX100
119 Dell PowerEdge 2850 Red Hat RHEL [EM64T] 4.0 U1 AS/ES v2.6.9−11.EL49 PCI, QLogic QLA200−E−SP2, 6, 50, 55 FC−AL, EMC Y19, 48
PCI−X FC−SW CLARiiON
AX100
120 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LP1050−E2, 4, 17, 35 ; FC−AL, EMC Y
BX620: S2F46, S246; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Fujitsu Siemens BX600−FC22Q2, 9, 11 FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
Fujitsu Siemens Primergy
BX630: (2−way), (4−way)
121 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LP101−E2, 4, 7, 17; FC−AL, EMC Y18, 19
2800, 2850, 6800, 6850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express QLogic: QLA200−E−SP2, 6, 23, FC−SW CLARiiON
v2.6.9−22.0.2.EL QLA210−E−SP2, 6, 23 AX100
Digital Henge Revo:
JS1400, JS2400
122 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LP1050Ex−E2, 4, 7, 17; FC−AL, EMC Y18, 19
1850, 1950, 2800, 2850, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express QLogic QLE2360−E−SP2, 23, 42, 43 FC−SW CLARiiON
6800, 6850; v2.6.9−22.0.2.EL AX100
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
Lenovo SureServer:
R650, T650;
Samsung ZSS150
123 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LPe111−E2, 4, 17, 39 FC−AL, EMC Y18, 19
1850, 1950, 2800, 2850, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express FC−SW CLARiiON
6800, 6850; v2.6.9−22.0.2.EL AX100
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30;
Lenovo SureServer:
R650, T650;
Samsung ZSS150

11/02/2006 135 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
124 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LPe1150−E2, 4, 17, 41 FC−AL, EMC Y18, 19
1850, 1950, 2800, 2850, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express FC−SW CLARiiON
6800, 6850; v2.6.9−22.0.2.EL AX100
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30
125 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LPe1150−E2, 4, 41, 86 FC−AL, EMC Y18, 19
JS1400, JS2400; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
Lenovo SureServer:
R650, T650;
Samsung ZSS150
126 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex: LP1050−E2, 4, 8, 17, LP982−E2, 4, FC−AL, EMC Y18, 19
2800, 2850 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express 17; FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
QLogic QLA2340−E−SP2, 9, 23
127 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4, FC−AL, EMC Y18, 19
DL360(G4)30, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express 17, AD167A/FC2143 (LP1150)2, 4, 17, 29 FC−SW CLARiiON
DL380(G4)30, v2.6.9−22.0.2.EL AX100
DL580(G3)30,
ML350(G4)30,
ML370(G4)30
128 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI QLogic QLE2460−E−SP2, 23, 53 FC−AL, EMC Y18, 19
1850, 1950, 2800, 2850, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express FC−SW CLARiiON
6800, 6850; v2.6.9−22.0.2.EL AX100
Digital Henge Revo:
JS1400, JS2400;
Lenovo SureServer:
R650, T650;
Samsung ZSS150
129 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex LP101−E2, 4, 7, 17; FC−AL, EMC Y18, 19
2950, 6800, 6850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express, QLogic: QLA200−E−SP2, 6, 23, FC−SW CLARiiON
v2.6.9−22.0.2.EL PCI−X QLA210−E−SP2, 6, 23 AX100
HPQ Proliant
ML350(G4)30
130 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex: LP1050−E2, 4, 8, 17, LP982−E2, 4, FC−AL, EMC Y18, 19
2950, 6800, 6850 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express, 17; FC−SW CLARiiON
v2.6.9−22.0.2.EL PCI−X AX100
QLogic QLA2340−E−SP2, 9, 23
131 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex: LP1050−E4, 8, 17, LP982−E4, 17; FC−AL, EMC Y18, 19
ML350(G4)30 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express, FC−SW CLARiiON
v2.6.9−22.0.2.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 23, 36, AX100
AD167A/FC2143 (LP1150)2, 4, 17, 29 ,
AE369A/FC1243 (QLA2462)2, 23, 36;
QLogic QLA2340−E−SP9, 23
132 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex: LP1050Ex−E2, 4, 7, 17, LPe111−E2, FC−AL, EMC Y18, 19
2950 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express, 4, 17, 39, LPe1150−E2, 4, 17, 41 ; FC−SW CLARiiON
v2.6.9−22.0.2.EL PCI−X AX100
QLogic: QLE2360−E−SP2, 23, 42, 43 ,
QLE2460−E−SP2, 23, 53
133 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI Emulex: LP101−E2, 4, 7, 17, LP1050−E4, 8, FC−AL, EMC Y18, 19
JS1400, JS2400 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express, 17, LP982−E4, 17; FC−SW CLARiiON
v2.6.9−22.0.2.EL PCI−X 31 AX100
QLogic: QLA200−E−SP2, 6, 23,
QLA210−E−SP2, 6, 23, QLA2340−E−SP9, 23
134 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Dell: 2342M9, 23, LPe1105−M2, 4, 17, 41 , FC−AL, EMC Y18, 19
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES QME24622, 23, 56 FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
135 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Emulex LP101−E2, 4, 7, 17; FC−AL, EMC Y18, 19
1950; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES QLogic QLA200−E−SP2, 6, 23 FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
136 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Emulex LP1050−E2, 4, 8, 17; FC−AL, EMC Y18, 19
1950; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES QLogic QLA2340−E−SP2, 9, 23 FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840, ZSS150

11/02/2006 136 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
137 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Emulex LP1050Ex−E2, 4, 17, 35 FC−AL, EMC Y
RX200 S2 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
138 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Emulex LP982−E2, 4, 17 FC−AL, EMC Y18, 19
Digital Henge SH4500R4; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
IBM xSeries: x255, x336 v2.6.9−22.0.2.EL AX100
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NF420;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840, ZSS150
139 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Emulex: LP1050−E4, 8, 17, LP982−E4, 17; FC−AL, EMC Y18, 19
DL360(G4)30 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.2.EL HPQ: AB429A/FC1143 (QLA2460)2, 23, 36, AX100
AD167A/FC2143 (LP1150)2, 4, 17, 29 ,
AE369A/FC1243 (QLA2462)2, 23, 36
140 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X NEC N8190−120 (LP1050)4, 7, 16, 17 FC−AL, EMC Y18, 19
120Lh, 120Re−1, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
120Rf−1, 120Rg−2, v2.6.9−22.0.2.EL AX100
120Rh−2, 140He,
140Rd−4
141 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X NEC N8190−127 (LPe1150)1, 4, 16, 17 FC−AL, EMC Y18, 19
140He, 140Rd−4 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
142 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X QLogic QLA210−E−SP2, 6, 23 FC−AL, EMC Y18, 19
Digital Henge SH4500R4; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
HPQ Proliant v2.6.9−22.0.2.EL AX100
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
143 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X QLogic QLA2340−E−SP9, 23 FC−AL, EMC Y18, 19
HPQ Proliant U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
DL360(G4)30; v2.6.9−22.0.2.EL AX100
LangChao: NC2000,
NF420;
Lenovo SureServer:
R630 6004, T630 6003
144 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X QLogic: QLA200−E−SP2, 6, 23, FC−AL, EMC Y
Primergy: RX300 S2, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES QLA210−E−SP2, 6, 23 FC−SW CLARiiON
TX200 S2, TX300 S2 v2.6.9−22.0.2.EL AX100
145 HPQ Proliant BL20p (G3) Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X12 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y18, 19
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Channel Mezzanine HBA − 394757−B214, FC−SW CLARiiON
v2.6.9−22.0.2.EL 13, 15, 17 AX100
146 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X22 Emulex: LP1050−E2, 4, 8, 17, LP982−E2, 4, FC−AL, EMC Y18, 19
(8865)20, 21, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES 17; FC−SW CLARiiON
x3950/x3950E/x460 v2.6.9−22.0.2.EL AX100
(8872, 8874)20, 21 QLogic QLA2340−E−SP2, 9, 23
147 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI, PCI Dell: LPe1105−M2, 4, 17, 41 , QME24622, 23, FC−AL, EMC Y18, 19
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express, 56 FC−SW CLARiiON
v2.6.9−22.0.2.EL PCI−X AX100
148 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI, Emulex LP1050−E2, 4, 17, 35 ; FC−AL, EMC Y
RX800 S2 U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X QLogic: QLA2340−E−SP2, 9, 23, FC−SW CLARiiON
v2.6.9−22.0.2.EL QLA2340−E−SP9, 23 AX100
149 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI, Emulex: LP101−E2, 4, 7, 17, LP1050−E4, 8, FC−AL, EMC Y18, 19
DL380(G4)30, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X 17, LP982−E4, 17; FC−SW CLARiiON
DL580(G3)30, v2.6.9−22.0.2.EL AX100
ML370(G4)30 QLogic: QLA200−E−SP2, 6, 23,
QLA210−E−SP2, 6, 23, QLA2340−E−SP9, 23
150 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI, Emulex: LP1050−E2, 4, 8, 17, LP982−E2, 4, FC−AL, EMC Y18, 19
1850, 2800, 2850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X 17; FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
IBM xSeries: x365, x440, QLogic QLA2340−E−SP2, 9, 23
x445 (8870);
Samsung: ES470,
ES570, SS140
151 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI, HPQ: AB429A/FC1143 (QLA2460)2, 23, 36, FC−AL, EMC Y18, 19
DL380(G4)30, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X AD167A/FC2143 (LP1150)2, 4, 17, 29 , FC−SW CLARiiON
ML370(G4)30 v2.6.9−22.0.2.EL AE369A/FC1243 (QLA2462)2, 23, 36 AX100
152 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X Emulex: LP101−E2, 4, 35, LP101−E4, 35, FC−AL, EMC Y
Primergy: RX300 S2, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES LP1050−E2, 4, 35; FC−SW CLARiiON
TX200 S2, TX300 S2 v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ AS/ES AX100
v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL Fujitsu Siemens S26361−F2843−E1
(Emulex LP9802)4, 35;
QLogic QLA2340−E−SP9
153 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL28, PCI Emulex LP1050Ex−E2, 4, 7, 17; FC−AL, EMC Y18, 19
HR−4850, HR−6850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express QLogic QLE2360−E−SP23, 42, 43 FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230

11/02/2006 137 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
154 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL28, PCI Emulex: LP101−E4, 7, 17, LP1050−E4, 8, 17, FC−AL, EMC Y18, 19
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express LP982−E2, 4, 17, LP982−E4, 17; FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
QLogic QLA2340−E−SP9, 23
155 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL28, PCI Emulex: LPe111−E2, 4, 17, 39 , LPe1150−E2, FC−AL, EMC Y18, 19
HR−4850, HR−6850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Express 4, 41, 86; FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
LangChao: NC3000, QLogic: QLE2360−E−SP2, 23, 42, 43 ,
NC3500, NF520; QLE2460−E−SP2, 23, 53
Samsung ZSS230
156 LangChao: NC3000, Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL28, PCI−X Emulex LP1050−E2, 4, 8, 17; FC−AL, EMC Y18, 19
NC3500, NF500, NF520; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES QLogic QLA2340−E−SP2, 9, 23 FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
Samsung ZSS230
157 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL28, PCI−X Emulex LP982−E2, 4, 17 FC−AL, EMC Y18, 19
HR−4850, HR−6850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
158 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL28, PCI−X Emulex: LP101−E4, 7, 17, LP1050−E4, 8, 17, FC−AL, EMC Y18, 19
HR−4850, HR−6850; U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES LP982−E4, 17; FC−SW CLARiiON
v2.6.9−22.0.2.EL AX100
LangChao: NC3000, QLogic QLA2340−E−SP9, 23
NC3500, NF500, NF520
159 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050−E2, 4, 14, 35 FC−AL, EMC Y
BX620: S2F46, S246; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy
BX630: (2−way), (4−way)
160 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Fujitsu Siemens BX600−FC22Q2, 9, 10, 11 FC−AL, EMC Y
BX620: S2F46, S246, S3; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy
BX630: (2−way),
(4−way), (8−way)
161 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP101−E2, 4, 7, 14; FC−AL, EMC Y
2800, 2850, 6800, 6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express QLogic: QLA200−E−SP2, 6, 10, FC−SW CLARiiON
v2.6.9−34.0.2.EL QLA210−E−SP2, 6, 10 AX100
Digital Henge Revo:
JS1400, JS2400
162 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050−E2, 4, 8, 14; FC−AL, EMC Y
2800, 2850 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express QLogic QLA2340−E−SP2, 9, 10 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
163 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050Ex−E2, 4, 7, 14 FC−AL, EMC Y
1850, 1950, 2800, 2850, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
6800, 6850; v2.6.9−34.0.2.EL AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
164 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP982−E2, 4, 14 FC−AL, EMC Y
2800, 2850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Samsung ZSS230
165 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex: LP101−E4, 7, 14, LP1050−E4, 8, 14, FC−AL, EMC Y
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express LP982−E4, 14; FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
QLogic QLA2340−E−SP9, 10
166 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex: LPe111−E2, 4, 14, 39 , LPe1150−E2, FC−AL, EMC Y
1850, 1950, 2800, 2850, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express 4, 14, 41 FC−SW CLARiiON
6800, 6850; v2.6.9−34.0.2.EL AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230

11/02/2006 138 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
167 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 4, FC−AL, EMC Y
DL360(G4)30, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express 14, AD167A/FC2143 (LP1150)2, 4, 14, 29 FC−SW CLARiiON
DL380(G4)30, v2.6.9−34.0.2.EL AX100
DL580(G3)30,
ML350(G4)30,
ML370(G4)30
168 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE220−E−SP2, 32, 33, 34 FC−AL, EMC Y
JS1400, JS2400 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
169 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE220−E−SP2, 33, 34 FC−AL, EMC Y
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
170 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE2360−E−SP2, 10, 42, 43 FC−AL, EMC Y
1850, 1950, 2800, 2850, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
6800, 6850; v2.6.9−34.0.2.EL AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
171 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE2360−E−SP10, 42, 43 FC−AL, EMC Y
HR−4850, HR−6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
172 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE2460−E−SP2, 10, 53 FC−AL, EMC Y
1850, 1950, 2800, 2850, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express FC−SW CLARiiON
6800, 6850; v2.6.9−34.0.2.EL AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
173 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP101−E2, 4, 7, 14; FC−AL, EMC Y
2950, 6800, 6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, QLogic: QLA200−E−SP2, 6, 10, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X QLA210−E−SP2, 6, 10 AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
HPQ Proliant
ML350(G4)30;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
174 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050−E2, 4, 8, 14 FC−AL, EMC Y
2950, 6800, 6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
175 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050Ex−E2, 4, 14 FC−AL, EMC Y
RX220 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
176 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050Ex−E2, 4, 14, 35 ; FC−AL, EMC Y
Primergy: RX220, RX600 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, QLogic QLA2340−E−SP9 FC−SW CLARiiON
S3, TX600 S3 v2.6.9−34.0.2.EL PCI−X AX100
177 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP1050Ex−E2, 4, 7, 14 FC−AL, EMC Y
2950; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens
Primergy: RX600 S3,
TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 139 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
178 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LP982−E2, 4, 14 FC−AL, EMC Y
2950, 6800, 6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
179 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LPe111−E2, 4, 14, 39 ; FC−AL, EMC Y
2950; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, QLogic: QLE2360−E−SP2, 10, 42, 43 , FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X QLE2460−E−SP2, 10, 53 AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
180 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex LPe1150−E2, 4, 14, 41 FC−AL, EMC Y
2950; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens
Primergy: RX220, RX600
S3, TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
181 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex: LP1050−E4, 8, 14, LP982−E4, 14; FC−AL, EMC Y
ML350(G4)30 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 36, 37, AX100
AD167A/FC2143 (LP1150)2, 4, 14, 29 ,
AE369A/FC1243 (QLA2462)2, 36, 38;
QLogic QLE220−E−SP2, 32, 33, 34
182 IBM xSeries: x3550 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI IBM: 24P0960 (QLA2340)2, 9, 10, 73 , FC−AL, EMC Y
(7978), x3650 (7979) U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, 24P8053 (QLA2342)2, 9, 10, 39M5894 FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X (QLA2460)2, 39M5895 (QLA2462)2; AX100
QLogic: QLA2460−E−SP2, 10, 78,
QLE2360−E−SP2, 10, 79, QLE2460−E−SP2,
10, 78

183 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI NEC: N8190−120 (LP1050)8, 16, 74, 75 , FC−AL, EMC Y
120Li, 120Rg−1, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, N8190−127 (LPe1150)16, 41, 74, 75 FC−SW CLARiiON
120Ri−2, 140Hf, v2.6.9−34.0.2.EL PCI−X AX100
140Re−4
184 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLA2340−E−SP2, 9, 10 FC−AL, EMC Y
2950, 6800, 6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens
Primergy: RX220, RX600
S3, TX600 S3;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
185 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
Primergy: RX220, RX600 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
S3, TX600 S3; v2.6.9−34.0.2.EL PCI−X AX100
HPQ Proliant
ML350(G4)30
186 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI QLogic QLE220−E−SP2, 33, 34 FC−AL, EMC Y
1900, 2850, 2900, 2950, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
6800, 6850; v2.6.9−34.0.2.EL PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
187 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI Emulex: LP101−E2, 4, 7, 14, LP1050−E4, 8, FC−AL, EMC Y
JS1400, JS2400 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, 14, LP982−E4, 14; FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X31 AX100
QLogic: QLA200−E−SP2, 6, 10,
QLA210−E−SP2, 6, 10, QLA2340−E−SP9,
10, QLE220−E−SP2, 32, 33, 34

188 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Dell: 2342M9, 10, LPe1105−M2, 4, 14, 41 , FC−AL, EMC Y
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QME24622, 10, 56 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
189 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex LP101−E2, 4, 7, 14; FC−AL, EMC Y
1950; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA200−E−SP2, 6, 10 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003

11/02/2006 140 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
190 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex LP101−E4, 7, 14 FC−AL, EMC Y
HR−4850, HR−6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
LangChao: NC3000,
NC3500, NF500, NF520
191 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex LP1050−E2, 4, 8, 14; FC−AL, EMC Y
1950; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA2340−E−SP2, 9, 10 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840,
ZSS150, ZSS230
192 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex LP1050Ex−E2, 4, 14, 35 FC−AL, EMC Y
Primergy: RX200 S2, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
RX600 S2, TX600 S2 v2.6.9−34.0.2.EL AX100
193 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex LP982−E2, 4, 14 FC−AL, EMC Y
Digital Henge INNO: U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
HR−4850, HR−6850; v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)24, x346 (8840)24,
x3850/x366 (8863)20, 21;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840,
ZSS150, ZSS230
194 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X Emulex: LP1050−E4, 8, 14, LP982−E4, 14 FC−AL, EMC Y
HR−4850, HR−6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
HPQ Proliant
DL360(G4)30;
LangChao: NC3000,
NC3500, NF500, NF520
195 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y18, 19
(416653−B21), U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES HP c−Class Bladesystem: (403621−B21)14, FC−SW CLARiiON
(416654−B21), v2.6.9−34.0.2.EL 83, 84, (403621−B21)14, 84, 91 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
196 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416653−B21), U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES HP c−Class Bladesystem (403619−B21)38, FC−SW CLARiiON
(416654−B21), v2.6.9−34.0.2.EL 82 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
197 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 36, 37, FC−AL, EMC Y
DL360(G4)30 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AD167A/FC2143 (LP1150)2, 4, 14, 29 , FC−SW CLARiiON
v2.6.9−34.0.2.EL AE369A/FC1243 (QLA2462)2, 36, 38 AX100
198 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X NEC N8190−120 (LP1050)4, 7, 14, 16 FC−AL, EMC Y
120Lh, 120Re−1, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
120Rf−1, 120Rg−2, v2.6.9−34.0.2.EL AX100
120Rh−2, 140He,
140Rd−4
199 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X NEC N8190−127 (LPe1150)1, 4, 14, 16 FC−AL, EMC Y
140He, 140Rd−4 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
200 Fujitsu Siemens Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X QLogic QLA200−E−SP2, 6 FC−AL, EMC Y
Primergy: RX300 S2, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
TX200 S2, TX300 S2 v2.6.9−34.0.2.EL AX100

11/02/2006 141 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
201 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X QLogic QLA210−E−SP2, 6, 10 FC−AL, EMC Y
Digital Henge SH4500R4; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
Fujitsu Siemens v2.6.9−34.0.2.EL AX100
Primergy: RX300 S2,
TX200 S2, TX300 S2;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
202 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
HR−4850, HR−6850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)30;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer:
R630 6004, T630 6003
203 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X QLogic QLE220−E−SP2, 32, 33, 34 FC−AL, EMC Y
Fujitsu Siemens U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES FC−SW CLARiiON
Primergy: RX300 S2, v2.6.9−34.0.2.EL AX100
TX200 S2, TX300 S2;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
204 HPQ Proliant BL20p: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X12 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y
(G3), (G4) U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Channel Mezzanine HBA − 394757−B214, FC−SW CLARiiON
v2.6.9−34.0.2.EL 13, 14, 15 AX100
205 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, PCI Dell: LPe1105−M2, 4, 14, 41 , QME24622, 10, FC−AL, EMC Y
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, 56 FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
206 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, PCI Emulex: LP101−E2, 4, 7, 14, LP1050−E4, 8, FC−AL, EMC Y
DL580(G3)30 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, 14, LP982−E4, 14; FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
QLogic: QLA200−E−SP2, 6, 10,
QLA210−E−SP2, 6, 10, QLA2340−E−SP9,
10, QLE220−E−SP2, 32, 33, 34

207 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, PCI QLogic QLE220−E−SP2, 33, 34 FC−AL, EMC Y
2800 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.2.EL PCI−X AX100
208 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, Emulex LP1050−E2, 4, 14, 35 FC−AL, EMC Y
RX800 S2 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
209 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, Emulex: LP101−E2, 4, 7, 14, LP1050−E4, 8, FC−AL, EMC Y
DL380(G4)30, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X 14, LP982−E4, 14; FC−SW CLARiiON
ML370(G4)30 v2.6.9−34.0.2.EL AX100
HPQ: AB429A/FC1143 (QLA2460)2, 36, 37,
AD167A/FC2143 (LP1150)2, 4, 14, 29 ,
AE369A/FC1243 (QLA2462)2, 36, 38;
QLogic: QLA200−E−SP2, 6, 10,
QLA210−E−SP2, 6, 10, QLE220−E−SP2, 32,
33, 34

210 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, Emulex: LP1050−E2, 4, 8, 14, LP982−E2, 4, FC−AL, EMC Y
1850, 2800, 2850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X 14 FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470,
ES570, SS140
211 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, QLogic QLA2340−E−SP2, 9, 10 FC−AL, EMC Y
1850, 2800, 2850; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.2.EL AX100
Fujitsu Siemens Primergy
RX800 S2;
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470,
ES570, SS140
212 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI, QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
RX800 S2; U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
HPQ Proliant: v2.6.9−34.0.2.EL AX100
DL380(G4)30,
ML370(G4) 30

213 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP101−E2, 3, 4, 7; FC−AL, EMC Y
2800, 2850, 6800, 6850; U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic: QLA200−E−SP2, 5, 6, FC−SW CLARiiON
QLA210−E−SP2, 5, 6 AX100
Digital Henge Revo:
JS1400, JS2400
214 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP1050−E2, 3, 4, 8; FC−AL, EMC Y
2800, 2850 U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic QLA2340−E−SP2, 5, 9 FC−SW CLARiiON
AX100

11/02/2006 142 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
215 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP1050Ex−E2, 3, 4, 7 FC−AL, EMC Y
1850, 1950, 2800, 2850, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
216 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP982−E2, 3, 4 FC−AL, EMC Y
2800, 2850; U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
Samsung ZSS230
217 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex: LP101−E3, 4, 7, LP1050−E3, 4, 8, FC−AL, EMC Y
U4+ AS/ES v2.6.9−42.0.2.EL Express LP982−E3, 4; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP5, 9
218 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex: LPe111−E2, 3, 4, 39, LPe1150−E2, FC−AL, EMC Y
1850, 1950, 2800, 2850, U4+ AS/ES v2.6.9−42.0.2.EL Express 3, 4, 41 FC−SW CLARiiON
6800, 6850; AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)30,
DL380(G4)30,
DL580(G3)30,
ML350(G4)30,
ML370(G4)30;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
219 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI HPQ: A8002A/FC2142SR (LPe1150)1, 2, 3, FC−AL, EMC Y
DL360(G4)30, U4+ AS/ES v2.6.9−42.0.2.EL Express 4, AD167A/FC2143 (LP1150)2, 3, 4, 29 FC−SW CLARiiON
DL380(G4)30, AX100
DL580(G3)30,
ML350(G4)30,
ML370(G4)30
220 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE220−E−SP2, 32, 33, 47 FC−AL, EMC Y
JS1400, JS2400 U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
221 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE220−E−SP2, 33, 47 FC−AL, EMC Y
U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
222 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE2360−E−SP2, 5, 42, 43 FC−AL, EMC Y
1850, 1950, 2800, 2850, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)24;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
223 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE2360−E−SP5, 42, 43 FC−AL, EMC Y
HR−4850, HR−6850; U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX100
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230

11/02/2006 143 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
224 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE2460−E−SP2, 5, 53 FC−AL, EMC Y
1850, 1950, 2800, 2850, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
225 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP101−E2, 3, 4, 7; FC−AL, EMC Y
2950, 6800, 6850; U4+ AS/ES v2.6.9−42.0.2.EL Express, QLogic: QLA200−E−SP2, 5, 6, FC−SW CLARiiON
PCI−X QLA210−E−SP2, 5, 6 AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
HPQ Proliant
ML350(G4)30;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
226 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP1050−E2, 3, 4, 8; FC−AL, EMC Y
2950, 6800, 6850; U4+ AS/ES v2.6.9−42.0.2.EL Express, QLogic QLA2340−E−SP2, 5, 9 FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
227 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex LP982−E2, 3, 4 FC−AL, EMC Y
2950, 6800, 6850; U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
228 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex: LP1050−E3, 4, 8, LP982−E3, 4; FC−AL, EMC Y
ML350(G4)30 U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 5, 36, AX100
AD167A/FC2143 (LP1150)2, 3, 4, 29,
AE369A/FC1243 (QLA2462)2, 5, 36;
QLogic: QLA2340−E−SP5, 9,
QLE220−E−SP2, 32, 33, 47
229 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex: LP1050Ex−E2, 3, 4, 7, LPe111−E2, FC−AL, EMC Y
2950; U4+ AS/ES v2.6.9−42.0.2.EL Express, 3, 4, 39, LPe1150−E2, 3, 4, 41; FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: QLogic: QLE2360−E−SP2, 5, 42, 43 ,
AS1500, AS1550, QLE2460−E−SP2, 5, 53
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
230 IBM xSeries: x3550 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI IBM: 24P0960 (QLA2340)2, 5, 9, 73, FC−AL, EMC Y
(7978), x3650 (7979) U4+ AS/ES v2.6.9−42.0.2.EL Express, 24P8053 (QLA2342)2, 5, 9; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA2460−E−SP2, 5, 78,
QLE2360−E−SP2, 5, 79, QLE2460−E−SP2,
5, 78

231 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI NEC: N8190−120 (LP1050)3, 8, 16, 75 , FC−AL, EMC Y
120Li, 120Rg−1, U4+ AS/ES v2.6.9−42.0.2.EL Express, N8190−127 (LPe1150)3, 16, 41, 75 FC−SW CLARiiON
120Ri−2, 140Hf, PCI−X AX100
140Re−4
232 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI QLogic QLE220−E−SP2, 33, 47 FC−AL, EMC Y
1900, 2850, 2900, 2950, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
6800, 6850; PCI−X AX100
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
233 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI Emulex: LP101−E2, 3, 4, 7, LP1050−E3, 4, 8, FC−AL, EMC Y
JS1400, JS2400 U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E3, 4; FC−SW CLARiiON
PCI−X31 AX100
QLogic: QLA200−E−SP2, 5, 6,
QLA210−E−SP2, 5, 6, QLA2340−E−SP5, 9,
QLE220−E−SP2, 32, 33, 47
234 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Dell: 2342M5, 9, LPe1105−M2, 3, 4, 41, FC−AL, EMC Y
U4+ AS/ES v2.6.9−42.0.2.EL QME24622, 5, 56 FC−SW CLARiiON
AX100

11/02/2006 144 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
235 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Emulex LP101−E2, 3, 4, 7; FC−AL, EMC Y
1950; U4+ AS/ES v2.6.9−42.0.2.EL QLogic QLA200−E−SP2, 5, 6 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
236 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Emulex LP101−E3, 4, 7 FC−AL, EMC Y
HR−4850, HR−6850; U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
LangChao: NC3000,
NC3500, NF500, NF520
237 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Emulex LP1050−E2, 3, 4, 8; FC−AL, EMC Y
1950; U4+ AS/ES v2.6.9−42.0.2.EL QLogic QLA2340−E−SP2, 5, 9 FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840,
ZSS150, ZSS230
238 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Emulex LP982−E2, 3, 4 FC−AL, EMC Y
Digital Henge INNO: U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
HR−4850, HR−6850; AX100
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)24, x346 (8840)24;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer
R630: 6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210,
SS370, SS3840,
ZSS150, ZSS230
239 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X Emulex: LP1050−E3, 4, 8, LP982−E3, 4 FC−AL, EMC Y
HR−4850, HR−6850; U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
HPQ Proliant
DL360(G4)30;
LangChao: NC3000,
NC3500, NF500, NF520
240 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y18, 19
(416653−B21), U4+ AS/ES v2.6.9−42.0.2.EL HP c−Class Bladesystem (403621−B21)3, FC−SW CLARiiON
(416654−B21), 84, 90 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
241 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416653−B21), U4+ AS/ES v2.6.9−42.0.2.EL HP c−Class Bladesystem (403619−B21)5, FC−SW CLARiiON
(416654−B21), 82 AX100
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
242 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 5, 36, FC−AL, EMC Y
DL360(G4)30 U4+ AS/ES v2.6.9−42.0.2.EL AD167A/FC2143 (LP1150)2, 3, 4, 29, FC−SW CLARiiON
AE369A/FC1243 (QLA2462)2, 5, 36 AX100
243 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X NEC N8190−120 (LP1050)3, 4, 7, 16 FC−AL, EMC Y
120Lh, 120Re−1, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
120Rf−1, 120Rg−2, AX100
120Rh−2, 140He,
140Rd−4
244 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X NEC N8190−127 (LPe1150)1, 3, 4, 16 FC−AL, EMC Y
140He, 140Rd−4 U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100

11/02/2006 145 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
245 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X QLogic QLA210−E−SP2, 5, 6 FC−AL, EMC Y
Digital Henge SH4500R4; U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
HPQ Proliant AX100
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
246 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X QLogic QLA2340−E−SP5, 9 FC−AL, EMC Y
HR−4850, HR−6850; U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX100
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)30;
LangChao: NC2000,
NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer:
R630 6004, T630 6003
247 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X QLogic QLE220−E−SP2, 32, 33, 47 FC−AL, EMC Y
Fujitsu Siemens U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
Primergy: RX300 S2, AX100
TX200 S2, TX300 S2;
HPQ Proliant
DL360(G4)30;
LangChao NF420;
Lenovo SureServer:
R630 6004, T630 6003
248 HPQ Proliant BL20p: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X12 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y
(G3), (G4) U4+ AS/ES v2.6.9−42.0.2.EL Channel Mezzanine HBA − 394757−B213, FC−SW CLARiiON
4, 13, 15 AX100
249 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, PCI Dell: LPe1105−M2, 3, 4, 41, QME24622, 5, 56 FC−AL, EMC Y
U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX100
250 HPQ Proliant DL380(G5) Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, PCI Emulex: LP101−E2, 3, 4, 7, LP1050−E3, 4, 8, FC−AL, EMC Y
U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E3, 4; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)2, 5, 36,
AE369A/FC1243 (QLA2462)2, 5, 36;
QLogic: QLA200−E−SP2, 5, 6,
QLA210−E−SP2, 5, 6, QLA2340−E−SP5, 9
251 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, PCI Emulex: LPe111−E2, 3, 4, 39, LPe1150−E2, FC−AL, EMC Y
DL380(G5), DL580(G4) U4+ AS/ES v2.6.9−42.0.2.EL Express, 3, 4, 41; FC−SW CLARiiON
PCI−X AX100
HPQ: A8002A/FC2142SR (LPe1150)1, 2, 3,
4, AD167A/FC2143 (LP1150)2, 3, 4, 29 ,
AE311A/FC1142SR (QLE2460)2, 5, 53,
AE312A/FC1242SR (QLE2462)2, 5, 53;
QLogic: QLE2460−E−SP2, 5, 53,
QLE2462−E−SP2, 5, 53
252 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, PCI QLogic QLE220−E−SP2, 32, 33, 47 FC−AL, EMC Y
DL380(G5), U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
DL580(G3)30, DL580(G4) PCI−X AX100
253 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, PCI QLogic QLE220−E−SP2, 33, 47 FC−AL, EMC Y
2800 U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX100
254 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, Emulex: LP101−E2, 3, 4, 7, LP1050−E3, 4, 8, FC−AL, EMC Y
DL380(G4)30, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X LP982−E3, 4; FC−SW CLARiiON
ML370(G4)30 AX100
HPQ: AB429A/FC1143 (QLA2460)2, 5, 36,
AD167A/FC2143 (LP1150)2, 3, 4, 29,
AE369A/FC1243 (QLA2462)2, 5, 36;
QLogic: QLA200−E−SP2, 5, 6,
QLA210−E−SP2, 5, 6, QLA2340−E−SP5, 9,
QLE220−E−SP2, 32, 33, 47
255 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI, Emulex: LP1050−E2, 3, 4, 8, LP982−E2, 3, 4; FC−AL, EMC Y
1850, 2800, 2850; U4+ AS/ES v2.6.9−42.0.2.EL PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP2, 5, 9 AX100
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470,
ES570, SS140
256 IBM BladeCenter HS21 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y65
(Model 8853)66 26 Card (39Y9186)2, 45, 67, 68 , HS20 4GB SFF CLARiiON
FC Exp Card (26R0890)2, 27, 55, 60 , HS20 AX100
FC Exp Card (13N2203)2, 9, 27, HS20 FC
Exp Card (48P7061)2, 9, 27
257 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
(Model 8843) 26 Card (39Y9186)2, 45, 67, 68 , HS20 4GB SFF CLARiiON
FC Exp Card (26R0890)2, 27, 60, HS20 FC AX100
Exp Card (26K4841)2, 9, 27
258 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL25, PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, FC−SW EMC Y
(Model: 8832−N1X), 26 45, 52, HS20 4GB Standard FC Exp Card CLARiiON
8843) (26R0884)2, 27, 59, HS20 FC Exp Card AX100
(13N2203)2, 9, 27, HS20 FC Exp Card
(48P7061)2, 9, 27
259 IBM BladeCenter HS21 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y65
(Model 8853)66 26 Card (39Y9186)2, 40, 67, 68 , HS20 4GB SFF CLARiiON
FC Exp Card (26R0890)2, 55, 60, 72 , HS20 AX100
FC Exp Card (13N2203)2, 9, 72, HS20 FC
Exp Card (48P7061)2, 9, 72

11/02/2006 146 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
260 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
(Model 8843) 26 Card (39Y9186)2, 40, 67, 68 , HS20 4GB SFF CLARiiON
FC Exp Card (26R0890)2, 60, 72, HS20 FC AX100
Exp Card (26K4841)2, 9, 72
261 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL25, PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, FC−SW EMC Y
(Model: 8832−N1X), 26 40, 52, HS20 4GB Standard FC Exp Card CLARiiON
8843) (26R0884)2, 59, 72, HS20 FC Exp Card AX100
(13N2203)2, 9, 72, HS20 FC Exp Card
(48P7061)2, 9, 72
262 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)2, 9, 70, FC−SW EMC Y19, 48
(Model 8843) v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, 88 CLARiiON
62 AX100
263 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 9, 70, FC−SW EMC Y19, 48
(Model: 8832−N1X), v2.4.21−32.EL25, 62, U5+ AS/ES v2.4.21−32.0.1.EL25, 88,(48P7061)2, 9, 70, 88 CLARiiON
8843) 62 AX100
264 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC N19, 48
(Model 8843) U6+ AS/ES v2.4.21−37.0.1.EL (26R0890)2, 27, 60 CLARiiON
AX100
265 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC N19, 48
(Model: 8832−N1X), U6+ AS/ES v2.4.21−37.0.1.EL (26R0884)2, 27, 59 CLARiiON
8843) AX100
266 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X IBM HS20 FC Exp Card (26K4841)2, 9, 27 FC−SW EMC Y19, 48
(Model 8843) U6+ AS/ES v2.4.21−37.0.1.EL CLARiiON
AX100
267 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, FC−SW EMC Y19, 48
(Model: 8832−N1X), U6+ AS/ES v2.4.21−37.0.1.EL 52, 57, HS20 FC Exp Card (13N2203)2, 9, 27, CLARiiON
8843) HS20 FC Exp Card (48P7061)2, 9, 27 AX100
268 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y18, 19
(Model 8843) U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES (26R0890)2, 55, 60, 85 , FC Exp Card CLARiiON
v2.6.9−22.0.2.EL (26K4841)2, 9, 23 AX100
269 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, FC−SW EMC Y18, 19
(Model: 8832−N1X), U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES 17, 52, HS20 4GB Standard FC Exp Card CLARiiON
8843) v2.6.9−22.0.2.EL (26R0884)2, 23, 59, HS20 FC Exp Card AX100
(13N2203)2, 9, 23, HS20 FC Exp Card
(48P7061)2, 9, 23
270 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X IBM HS20 FC Exp Card (26K4841)2, 9, 10 FC−SW EMC Y
(Model 8843) U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES CLARiiON
v2.6.9−34.0.2.EL AX100
271 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X IBM HS20 FC Exp Card: (13N2203)2, 9, 10, FC−SW EMC Y
(Model: 8832−N1X), U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES (48P7061)2, 9, 10 CLARiiON
8843); v2.6.9−34.0.2.EL AX100
IBM BladeCenter HS21
(Model 8853)66
272 IBM BladeCenter: HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
(Model 8843), HS21 U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Card (39Y9186)2, 14, 67, 68 , HS20 4GB SFF CLARiiON
(Model 8853)66 v2.6.9−34.0.2.EL FC Exp Card (26R0890)2, 10, 55, 60 AX100
273 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, PCI−X IBM: Emulex LP1005DC FC Exp Card2, 4, FC−SW EMC Y
(Model: 8832−N1X), U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 14, 52, HS20 4GB Standard FC Exp Card CLARiiON
8843) v2.6.9−34.0.2.EL (26R0884)2, 10, 59 AX100
274 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X IBM HS20 FC Exp Card (26K4841)2, 5, 9 FC−SW EMC Y
(Model 8843) U4+ AS/ES v2.6.9−42.0.2.EL CLARiiON
AX100
275 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X IBM HS20 FC Exp Card: (13N2203)2, 5, 9, FC−SW EMC Y
(Model: 8832−N1X), U4+ AS/ES v2.6.9−42.0.2.EL (48P7061)2, 5, 9 CLARiiON
8843); AX100
IBM BladeCenter HS21
(Model 8853)66
276 IBM BladeCenter: HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
(Model 8843), HS21 U4+ AS/ES v2.6.9−42.0.2.EL Card (39Y9186)2, 3, 67, 68 , HS20 4GB SFF CLARiiON
(Model 8853)66 FC Exp Card (26R0890)2, 5, 55, 60 AX100
277 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, PCI−X IBM: Emulex LP1005DC FC Exp Card2, 3, 4, FC−SW EMC Y
(Model: 8832−N1X), U4+ AS/ES v2.6.9−42.0.2.EL 52, HS20 4GB Standard FC Exp Card CLARiiON
8843) (26R0884)2, 5, 59 AX100
1. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. SNIA HBA API Supported.
3. Driver Version 8.0.16.27 Driver is integrated into the kernel.
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
6. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. Firmware Version 1.91a5
9. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
11. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
12. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
13. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
14. Driver Version 8.0.16.18 Driver is integrated into the kernel.
15. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
16. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
17. Driver Version 8.0.16.17 Driver is integrated into the kernel.
18. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
19. VxVM is not supported on servers booting from the array.
20. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
21. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
22. Accepts PCI−X 1.0 and 2.0 HBAs.
23. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
25. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
26. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
27. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
28. dual core machine not support

11/02/2006 147 CLARiiON AX100


CLARiiON AX100

29. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
31. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
32. Driver/BIOS are available at http://www.qlogic.com
33. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
34. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
35. Firmware Version 1.91a1
36. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
38. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
39. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
40. Driver Version 7.3.6 Driver is integrated into the kernel.
41. Firmware Version 2.50a6
42. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
43. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
44. Driver Version 7.07.00
45. Driver Version 7.3.3 Driver is integrated into the kernel.
46. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
47. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
48. Booting from the SAN with PowerPath is not supported.
49. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
50. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
51. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
52. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
53. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
54. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
55. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
56. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
57. Driver Version 7.3.2 Driver is integrated into the kernel.
58. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
59. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
60. BIOS 1.12
61. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
62. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file names
must be used.
63. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
64. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
65. PowerPath is not supported.
66. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
67. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
68. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
69. Driver Version 7.01.01 Driver is integrated into the kernel.
70. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
71. Driver Version 7.1.14 Driver is integrated into the kernel.
72. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
73. This HBA is equivalent to the QLogic QLA2340.
74. Driver Version 8.0.16.18
75. BIOS 1.70a3
76. BIOS 1.02
77. Driver Version 7.07.05
78. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
79. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
80. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
81. Driver Version 7.1.14
82. BIOS 1.16
83. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
84. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
85. Driver Version 8.01.00
86. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
87. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
88. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
89. Driver Version 8.0.16.6_x2−2 The Emulex 8.0.16.6_x2−2 package supersedes the Emulex 8.0.16.6_x2−1 package.
90. Firmware Version 2.50a8
91. Firmware Version 2.50a8 Driver is integrated into the kernel.
92. Driver Version 7.04.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
93. Driver Version 7.03.00 Driver is integrated into the kernel.

SuSE SLES [32−Bit]

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 106, 19, PCI Emulex LP101−E4, 9, 10, 27 ; FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; 20, 24, 25 QLogic QLA2340−E−SP35, 52 FC−SW CLARiiON
AX100
HPQ Proliant: DL36045, DL380(G3)45, DL580(G2)45,
ML350(G2)45, ML350(G3)45, ML530(G3)45
2 Fujitsu Siemens Primergy: BX620 S3, BX630 (2−way), SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050−E4, 10, 12, 27 FC−AL, EMC Y
BX630 (4−way) 20, 24, 25 FC−SW CLARiiON
AX100
3 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050−E4, 10, 27, 29 , FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 20, 24, 25 LP982−E4, 10, 27; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP4, 35, 52
4 HPQ Proliant: DL36045, ML350(G2)45, ML350(G3)45, SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050−E10, 27, 29, FC−AL, EMC Y
ML530(G3)45 20, 24, 25 LP982−E10, 27 FC−SW CLARiiON
AX100

11/02/2006 148 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
5 HPQ Proliant: DL36045, DL380(G3)45, DL580(G2)45, SuSE SLES [32−Bit] 106, 19, PCI HPQ AD167A/FC2143 (LP1150)4, FC−AL, EMC Y
ML350(G2)45, ML350(G3)45, ML530(G3)45 20, 24, 25 10, 27, 60 FC−SW CLARiiON
AX100
6 HPQ Proliant: DL32045, DL360(G2)45, DL36045, SuSE SLES [32−Bit] 106, 19, PCI QLogic QLE220−E−SP4, 16, 56, 58 FC−AL, EMC Y
DL380(G2)45, DL380(G3)45, DL38045, DL580(G2)45, 20, 24, 25 FC−SW CLARiiON
DL58045, ML350(G2)45, ML350(G3)45, ML35045, AX100
ML370(G2)45, ML37045, ML530(G2)45, ML530(G3)45,
ML53045, ML57045, ML75045
7 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050Ex−E4, 9, 10, 27 ; FC−AL, EMC Y
6850; 20, 24, 25 Express QLogic QLE2360−E−SP1, 4, 8, 52 FC−SW CLARiiON
AX100
IBM xSeries x336 (8837)26
8 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050Ex−E4, 10, 12, 27 FC−AL, EMC Y
20, 24, 25 Express FC−SW CLARiiON
AX100
9 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 106, 19, PCI Emulex LPe111−E4, 10, 18, 27 FC−AL, EMC Y
6850; 20, 24, 25 Express FC−SW CLARiiON
AX100
HPQ Proliant: DL360(G4)45, DL380(G4)45, DL580(G3)45,
ML350(G4)45, ML370(G4)45
10 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 106, 19, PCI Emulex LPe1150−E4, 10, 27, 28 FC−AL, EMC Y
6850; 20, 24, 25 Express FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy RX300 S3;
HPQ Proliant: DL360(G4)45, DL380(G4)45, DL580(G3)45,
ML350(G4)45, ML370(G4)45
11 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 106, 19, PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y2, 31,
(407234−B21), (407235−B21) 20, 24, 25 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON Y23
(403621−B21)21, 22, 76 AX100
12 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 106, 19, PCI HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(407234−B21), (407235−B21) 20, 24, 25 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(403619−B21)46, 75 AX100
13 HPQ Proliant: DL360(G4)45, DL380(G4)45, DL580(G3)45, SuSE SLES [32−Bit] 106, 19, PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y
ML350(G4)45, ML370(G4)45 20, 24, 25 Express (LPe1150)4, 10, 27, 57 , FC−SW CLARiiON
AD167A/FC2143 (LP1150)4, 10, 27, AX100
60

14 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 106, 19, PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(407234−B21), (407235−B21) 20, 24, 25 Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(403621−B21)21, 22, 76, QLogic AX100
QMH2462 4Gb FC HBA for HP
c−Class Bladesystem
(403619−B21)46, 75
15 Dell PowerEdge 1950 SuSE SLES [32−Bit] 106, 19, PCI QLogic QLE220−E−SP4, 16, 58 FC−AL, EMC Y
20, 24, 25 Express FC−SW CLARiiON
AX100
16 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 106, 19, PCI QLogic QLE2460−E−SP4, 32, 52 FC−AL, EMC Y
6850 20, 24, 25 Express FC−SW CLARiiON
AX100
17 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex LP101−E4, 9, 10, 27 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
HPQ Proliant ML350(G4)45;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
18 Fujitsu Siemens Primergy TX300 S3 SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050Ex−E4, 10, 12, 27 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
19 Fujitsu Siemens Primergy: RX600 S3, TX600 S3 SuSE SLES [32−Bit] 106, 19, PCI Emulex LP1050Ex−E4, 10, 27, 92 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
20 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex LPe1150−E4, 10, 27, 28 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
Fujitsu Siemens Primergy: RX200 S3, RX600 S3, TX300
S3, TX600 S3;
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
21 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050−E4, 10, 27, 29 , FC−AL, EMC Y
20, 24, 25 Express, LP982−E4, 10, 27; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
QLogic QLA2340−E−SP4, 35, 52
Intel: SR1500/S5000PAL, SR2500/S5000PAL
22 HPQ Proliant ML350(G4)45 SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050−E10, 27, 29, FC−AL, EMC Y
20, 24, 25 Express, LP982−E10, 27; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)4,
44, 52, AD167A/FC2143 (LP1150)4,
10, 27, 60 ;

QLogic: QLA2340−E−SP35, 52,


QLE220−E−SP4, 16, 56, 58
23 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 106, 19, PCI Emulex: LP1050Ex−E4, 9, 10, 27 , FC−AL, EMC Y
20, 24, 25 Express, LPe111−E4, 10, 18, 27 ; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; PCI−X AX100
QLogic: QLE2360−E−SP1, 4, 8, 52,
IBM eServer 326m (Model 7969); QLE2460−E−SP4, 32, 52
Intel: SR1500/S5000PAL, SR2500/S5000PAL

11/02/2006 149 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
24 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, SuSE SLES [32−Bit] 106, 19, PCI QLogic QLE220−E−SP4, 16, 58 FC−AL, EMC Y
6850, 6950; 20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
25 Dell PowerEdge 1855 SuSE SLES [32−Bit] 106, 19, PCI−X Dell LPe1105−M4, 10, 27, 28 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
AX100
26 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650, SuSE SLES [32−Bit] 106, 19, PCI−X Emulex LP101−E4, 9, 10, 27 FC−AL, EMC Y
6800, 6850; 20, 24, 25 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45,
ML570(G2)45;
IBM xSeries: x336 (8837)26, x346 (8840)26
27 Fujitsu Siemens Primergy: RX200 S2, RX300 S2, TX200 SuSE SLES [32−Bit] 106, 19, PCI−X Emulex LP1050−E4, 10, 12, 27 FC−AL, EMC Y
S2, TX300 S2 20, 24, 25 FC−SW CLARiiON
AX100
28 Fujitsu Siemens Primergy RX600 S2 SuSE SLES [32−Bit] 106, 19, PCI−X Emulex LP1050Ex−E4, 10, 27, 92 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
AX100
29 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE SLES [32−Bit] 106, 19, PCI−X Emulex LPe1150−E4, 10, 27, 28 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
AX100
30 Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 SuSE SLES [32−Bit] 106, 19, PCI−X Emulex: LP101−E4, 10, 12, 27 , FC−AL, EMC Y
S2 20, 24, 25 LP101−E10, 12, 27 FC−SW CLARiiON
AX100
31 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650, SuSE SLES [32−Bit] 106, 19, PCI−X Emulex: LP1050−E4, 10, 27, 29 , FC−AL, EMC Y
6800, 6850; 20, 24, 25 LP982−E4, 10, 27 FC−SW CLARiiON
AX100
IBM xSeries: x336 (8837)26, x346 (8840)26
32 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 106, 19, PCI−X Emulex: LP1050−E10, 27, 29, FC−AL, EMC Y
ML570(G2)45 20, 24, 25 LP982−E10, 27; FC−SW CLARiiON
AX100
HPQ AD167A/FC2143 (LP1150)4,
10, 27, 60

33 HPQ Proliant DL360(G4)45 SuSE SLES [32−Bit] 106, 19, PCI−X HPQ AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y
20, 24, 25 44, 52 FC−SW CLARiiON
AX100
34 Dell PowerEdge: 1600SC, 1650, 1750, 1950, 6800, 6850; SuSE SLES [32−Bit] 106, 19, PCI−X QLogic QLA2340−E−SP4, 35, 52 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
IBM xSeries: x336 (8837)26, x346 (8840)26 AX100
35 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 106, 19, PCI−X QLogic QLA2340−E−SP35, 52 FC−AL, EMC Y
20, 24, 25 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, AX100
ML570(G2)45
36 Fujitsu Siemens Primergy: RX300, RX300 S2, TX200 S2, SuSE SLES [32−Bit] 106, 19, PCI−X QLogic QLE220−E−SP4, 16, 56, 58 FC−AL, EMC Y
TX300, TX300 S2; 20, 24, 25 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45,
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45
37 Dell PowerEdge 1955 SuSE SLES [32−Bit] 106, 19, PCI, PCI Dell LPe1105−M4, 10, 27, 28 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
38 Fujitsu Siemens Primergy TX200 S3; SuSE SLES [32−Bit] 106, 19, PCI, PCI Emulex LPe1150−E4, 10, 27, 28 FC−AL, EMC Y
HPQ Proliant: DL380(G5), DL580(G4) 20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
39 HPQ Proliant: DL380(G5), DL580(G4) SuSE SLES [32−Bit] 106, 19, PCI, PCI Emulex: LP101−E4, 9, 10, 27 , FC−AL, EMC Y
20, 24, 25 Express, LP1050−E10, 27, 29, LP982−E10, 27, FC−SW CLARiiON
PCI−X LPe111−E4, 10, 18, 27 ; AX100
HPQ: A8002A/FC2142SR
(LPe1150)4, 10, 27, 57 ,
AB429A/FC1143 (QLA2460)4, 44, 52,
AD167A/FC2143 (LP1150)4, 10, 27,
60, AE311A/FC1142SR (QLE2460)4,
32, 52, AE312A/FC1242SR
(QLE2462)4, 32, 52;
QLogic: QLA2340−E−SP35, 52,
QLE220−E−SP4, 16, 56, 58 ,
QLE2460−E−SP4, 32, 52,
QLE2462−E−SP4, 32, 52
40 Dell PowerEdge: 1800, 2800 SuSE SLES [32−Bit] 106, 19, PCI, PCI QLogic QLE220−E−SP4, 16, 58 FC−AL, EMC Y
20, 24, 25 Express, FC−SW CLARiiON
PCI−X AX100
41 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850; SuSE SLES [32−Bit] 106, 19, PCI, Emulex LP101−E4, 9, 10, 27 FC−AL, EMC Y
20, 24, 25 PCI−X FC−SW CLARiiON
HPQ Proliant: DL380(G3)45, DL380(G4)45, DL38545, AX100
DL580(G2)45, DL580(G3)45, DL58545, ML370(G3)45,
ML370(G4)45
42 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850 SuSE SLES [32−Bit] 106, 19, PCI, Emulex: LP1050−E4, 10, 27, 29 , FC−AL, EMC Y
20, 24, 25 PCI−X LP982−E4, 10, 27; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP4, 35, 52
43 HPQ Proliant: DL380(G3)45, DL380(G4)45, DL38545, SuSE SLES [32−Bit] 106, 19, PCI, Emulex: LP1050−E10, 27, 29, FC−AL, EMC Y
DL580(G2)45, DL580(G3)45, DL58545, ML370(G3)45, 20, 24, 25 PCI−X LP982−E10, 27; FC−SW CLARiiON
ML370(G4)45 AX100
HPQ AD167A/FC2143 (LP1150)4,
10, 27, 60

11/02/2006 150 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
44 HPQ Proliant: DL380(G4)45, DL38545, DL58545, SuSE SLES [32−Bit] 106, 19, PCI, HPQ AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y
ML370(G4)45 20, 24, 25 PCI−X 44, 52 FC−SW CLARiiON
AX100
45 HPQ Proliant: DL380(G4)45, DL38545, DL580(G2)45, SuSE SLES [32−Bit] 106, 19, PCI, QLogic QLA2340−E−SP35, 52 FC−AL, EMC Y
DL580(G3)45, DL58545, ML370(G3)45, ML370(G4)45 20, 24, 25 PCI−X FC−SW CLARiiON
AX100
46 Fujitsu Siemens Primergy: RX600, TX600; SuSE SLES [32−Bit] 106, 19, PCI, QLogic QLE220−E−SP4, 16, 56, 58 FC−AL, EMC Y
20, 24, 25 PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, AX100
DL380(G4)45, DL38045, DL38545, DL580(G2)45,
DL580(G3)45, DL58545, ML370(G3)45, ML370(G4)45
47 Dell PowerEdge: 1650, 1750, 2600, 2650, 2850, 4600, SuSE SLES [32−Bit] 8 SP3 PCI−X Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
6600, 6650; v2.4.21−13819 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045,
DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries: x235, x255, x360, x365, x440;
Samsung SS3840
48 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, SuSE SLES [32−Bit] 8 SP3 PCI−X Emulex LP982−E10, 67 FC−AL, EMC N2, 3
4600, 6600, 6650; v2.4.21−13819 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045,
DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries: x235, x255, x360, x365, x440;
Samsung SS3840
49 Fujitsu Siemens Primergy: RX200, RX300, TX200, TX300 SuSE SLES [32−Bit] 8 SP3 PCI−X Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC N2, 3
v2.4.21−13819 (Emulex LP9802)10, 12, 93 FC−SW CLARiiON
AX100
50 Dell PowerEdge 1850; SuSE SLES [32−Bit] 8 SP3 PCI, Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
HPQ Proliant: DL14545, DL580(G3)45, DL58545, v2.4.21−13819 PCI−X FC−SW CLARiiON
ML370(G3)45; AX100
IBM xSeries: x345 (8670), x445 (8870)
51 Dell PowerEdge 1850; SuSE SLES [32−Bit] 8 SP3 PCI, Emulex LP982−E10, 67 FC−AL, EMC N2, 3
HPQ Proliant: DL380(G2)45, DL380(G3)45, DL38045, v2.4.21−13819 PCI−X FC−SW CLARiiON
DL580(G2)45, DL580(G3)45, ML370(G3)45; AX100
IBM xSeries: x345 (8670), x445 (8870)
52 Fujitsu Siemens Primergy: RX600, RX800, TX600 SuSE SLES [32−Bit] 8 SP3 PCI, Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC N2, 3
v2.4.21−13819 PCI−X (Emulex LP9802)10, 12, 93 FC−SW CLARiiON
AX100
53 Dell PowerEdge: 1800, 1850; SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
v2.4.21−19019 PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL580(G3)45, DL58545, AX100
ML370(G3)45;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
54 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8 SP3+ PCI QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.4.21−24119, 39 FC−SW CLARiiON
AX100
IBM: Netfinity 4500R, xSeries x225, xSeries x230, xSeries
x232, xSeries x240, xSeries x250, xSeries x330, xSeries
x335, xSeries x340 (4500R), xSeries x342, xSeries x350
(6000R), xSeries x370
55 HPQ Proliant: DL32045, DL360(G2)45, DL36045, DL58045, SuSE SLES [32−Bit] 8 SP3+ PCI QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45, v2.4.21−24119, 39 FC−SW CLARiiON
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045, AX100
ML75045

56 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, SuSE SLES [32−Bit] 8 SP3+ PCI−X QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
4600, 6600, 6650; v2.4.21−24119, 39 FC−SW CLARiiON
AX100
IBM xSeries: x235, x255, x360, x365, x440;
Samsung SS3840
57 HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045, SuSE SLES [32−Bit] 8 SP3+ PCI−X QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
DL760 (G2)45, DL76045, ML570(G2)45 v2.4.21−24119, 39 FC−SW CLARiiON
AX100
58 HPQ Proliant: DL14545, DL38545, DL58545 SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
v2.4.21−24119, 39 PCI−X QLogic QLA200−E−SP41, 43 FC−SW CLARiiON
AX100
59 Dell PowerEdge: 1800, 1850; SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
v2.4.21−24119, 39 PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL38545, DL580(G3)45, DL58545, AX100
ML370(G3)45;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
60 Dell PowerEdge 1850; SuSE SLES [32−Bit] 8 SP3+ PCI, QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
IBM xSeries: x345 (8670), x445 (8870) v2.4.21−24119, 39 PCI−X FC−SW CLARiiON
AX100
61 HPQ Proliant: DL380(G2)45, DL380(G3)45, DL38045, SuSE SLES [32−Bit] 8 SP3+ PCI, QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
DL580(G2)45, DL580(G3)45, ML370(G3)45 v2.4.21−24119, 39 PCI−X FC−SW CLARiiON
AX100

11/02/2006 151 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
62 Fujitsu Siemens Primergy BX620: S2F14, S214; SuSE SLES [32−Bit] 8 SP3+ PCI Fujitsu Siemens BX600−FC22Q4, 35, FC−AL, EMC N2, 3
v2.4.21−25119, 39 63, 74, 78 FC−SW CLARiiON
Fujitsu Siemens Primergy: BX62014, BX66014 AX100
63 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8 SP3+ PCI Emulex: LP1050−E10, 29, 67, FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.4.21−26619, 39 LP982−E10, 67 FC−SW CLARiiON
AX100
64 Dell PowerEdge: 2600, 2650, 2850, 4600, 6600, 6650 SuSE SLES [32−Bit] 8 SP3+ PCI−X Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
v2.4.21−26619, 39 QLogic: QLA200−E−SP41, FC−SW CLARiiON
QLA2340−E−SP35, 43 AX100
65 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2800, SuSE SLES [32−Bit] 8 SP3+ PCI−X Emulex: LP1050−E10, 29, 67, FC−AL, EMC N2, 3
2850, 4600, 6600, 6650 v2.4.21−26619, 39 LP982−E10, 67 FC−SW CLARiiON
AX100
66 Dell PowerEdge 1850 SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
v2.4.21−26619, 39 PCI−X QLogic QLA200−E−SP41 FC−SW CLARiiON
AX100
67 Dell PowerEdge: 1800, 1850 SuSE SLES [32−Bit] 8 SP3+ PCI, Emulex: LP1050−E10, 29, 67, FC−AL, EMC N2, 3
v2.4.21−26619, 39 PCI−X LP982−E10, 67 FC−SW CLARiiON
AX100
68 Fujitsu Siemens Primergy: RX200 S2, RX300 S2, TX200 SuSE SLES [32−Bit] 8 SP3+: PCI−X Emulex LP101−E10, 12, 93 FC−AL, EMC N2, 3
S2, TX300 S2 v2.4.21−19019, FC−SW CLARiiON
v2.4.21−24119, 39 AX100
69 Dell PowerEdge: 1650, 1750, 2600, 2650, 2800, 2850, SuSE SLES [32−Bit] 8 SP3+: PCI−X Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
4600, 6600, 6650; v2.4.21−19019, FC−SW CLARiiON
v2.4.21−24119, 39 AX100
HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045,
DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS3840
70 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2800, SuSE SLES [32−Bit] 8 SP3+: PCI−X Emulex LP982−E10, 67 FC−AL, EMC N2, 3
2850, 4600, 6600, 6650; v2.4.21−19019, FC−SW CLARiiON
v2.4.21−24119, 39 AX100
HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045,
DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer T630 6003;
Samsung: SS210, SS3840
71 Fujitsu Siemens Primergy: RX200, RX200 S2, RX300, SuSE SLES [32−Bit] 8 SP3+: PCI−X Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC N2, 3
RX300 S2, TX200, TX200 S2, TX300, TX300 S2 v2.4.21−19019, (Emulex LP9802)10, 12, 93 FC−SW CLARiiON
v2.4.21−24119, 39 AX100
72 Dell PowerEdge: 1800, 1850; SuSE SLES [32−Bit] 8 SP3+: PCI, Emulex LP982−E10, 67 FC−AL, EMC N2, 3
v2.4.21−19019, PCI−X FC−SW CLARiiON
HPQ Proliant: DL380(G2)45, DL380(G3)45, DL38045, v2.4.21−24119, 39 AX100
DL580(G2)45, DL580(G3)45, ML370(G3)45;
IBM xSeries: x345 (8670), x445 (8870);
Samsung SS140
73 Fujitsu Siemens Primergy: BX300, RX600, RX800, TX600 SuSE SLES [32−Bit] 8 SP3+: PCI, Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC N2, 3
v2.4.21−19019, PCI−X (Emulex LP9802)10, 12, 93 FC−SW CLARiiON
v2.4.21−24119, 39 AX100
74 Dell PowerEdge: 1800, 1850, 2800, 2850 SuSE SLES [32−Bit] 8 SP3+: PCI Emulex LP1050Ex−E4, 9, 10, 67 FC−AL, EMC N2, 3
v2.4.21−24119, 39, Express FC−SW CLARiiON
v2.4.21−26619, 39 AX100
75 IBM xSeries: x225, x335 SuSE SLES [32−Bit] 8 SP3+: PCI QLogic: QLA2340−E−SP35, 74, 86, FC−AL, EMC N2, 3
v2.4.21−25119, 39, QLA2340−E−SP35, 86 FC−SW CLARiiON
v2.4.21−26619, 39 AX100
76 IBM xSeries: x336 (8837)26, x346 (8840)26 SuSE SLES [32−Bit] 8 SP3+: PCI QLogic QLE2360−E−SP1, 8, 48 FC−AL, EMC N2, 3
v2.4.21−25119, 39, Express FC−SW CLARiiON
v2.4.21−26619, 39 AX100
77 IBM xSeries x336 (8837)26 SuSE SLES [32−Bit] 8 SP3+: PCI IBM 24P0960 (QLA2340)4, 35, 37, 74, FC−AL, EMC N2, 3
v2.4.21−25119, 39, Express, 78 FC−SW CLARiiON
v2.4.21−26619, 39 PCI−X AX100
78 LangChao: NC2000, NF420; SuSE SLES [32−Bit] 8 SP3+: PCI−X Emulex: LP1050−E10, 29, 40, FC−AL, EMC N2, 3
v2.4.21−25119, 39, LP982−E10, 40 FC−SW CLARiiON
Lenovo SureServer R630: 6003, 6004; v2.4.21−26619, 39 AX100
Lenovo SureServer T630 6003
79 IBM xSeries: x235, x255, x360, x440; SuSE SLES [32−Bit] 8 SP3+: PCI−X Emulex: LP1050−E10, 29, 50, FC−AL, EMC N2, 3
v2.4.21−25119, 39, LP982−E10, 50; FC−SW CLARiiON
Sun: V20z, V40z v2.4.21−26619, 39 AX100
QLogic: QLA2340−E−SP35, 74, 86,
QLA2340−E−SP35, 86
80 IBM xSeries x346 (8840)26 SuSE SLES [32−Bit] 8 SP3+: PCI−X IBM 24P0960 (QLA2340)4, 35, 37, 74, FC−AL, EMC N2, 3
v2.4.21−25119, 39, 78; FC−SW CLARiiON
v2.4.21−26619, 39 QLogic QLA2340−E−SP35, 49 AX100
81 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8 SP3+: PCI, QLogic: QLA2340−E−SP35, 74, 86, FC−AL, EMC N2, 3
v2.4.21−25119, 39, PCI−X QLA2340−E−SP35, 86 FC−SW CLARiiON
v2.4.21−26619, 39 AX100

11/02/2006 152 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
82 IBM xSeries: x225, x335 SuSE SLES [32−Bit] 8 SP3+: PCI Emulex LP982−E10, 50 FC−AL, EMC N2, 3
v2.4.21−25119, 39, FC−SW CLARiiON
v2.4.21−26619, 39; AX100
SuSE SLES [32−Bit] 8 SP4+:
v2.4.21−28119, 39,
v2.4.21−30419, 39,
v2.4.21−30619, 39,
v2.4.21−30919, 39
83 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8 SP3+: PCI, Emulex LP982−E10, 50 FC−AL, EMC N2, 3
v2.4.21−25119, 39, PCI−X FC−SW CLARiiON
v2.4.21−26619, 39; AX100
SuSE SLES [32−Bit] 8 SP4+:
v2.4.21−28119, 39,
v2.4.21−30419, 39,
v2.4.21−30619, 39,
v2.4.21−30919, 39
84 IBM xSeries: x225, x335 SuSE SLES [32−Bit] 8 SP3+: PCI Emulex LP1050−E10, 29, 50 FC−AL, EMC N2, 3
v2.4.21−25119, 39, FC−SW CLARiiON
v2.4.21−26619, 39; AX100
SuSE SLES [32−Bit] 8: SP4
v2.4.21−27819, 39, SP4+
v2.4.21−28119, 39, SP4+
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
85 IBM xSeries x336 (8837)26 SuSE SLES [32−Bit] 8 SP3+: PCI QLogic QLA2340−E−SP35 FC−AL, EMC N2, 3
v2.4.21−25119, 39, Express, FC−SW CLARiiON
v2.4.21−26619, 39; PCI−X AX100
SuSE SLES [32−Bit] 8: SP4
v2.4.21−27819, 39, SP4+
v2.4.21−28119, 39, SP4+
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
86 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8 SP3+: PCI, Emulex LP1050−E10, 29, 50 FC−AL, EMC N2, 3
v2.4.21−25119, 39, PCI−X FC−SW CLARiiON
v2.4.21−26619, 39; AX100
SuSE SLES [32−Bit] 8: SP4
v2.4.21−27819, 39, SP4+
v2.4.21−28119, 39, SP4+
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
87 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8 SP4+ PCI Emulex LP101−E9, 10, 50 FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.4.21−28119, 39 FC−SW CLARiiON
AX100
88 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 4600, SuSE SLES [32−Bit] 8 SP4+ PCI−X Emulex LP101−E9, 10, 50 FC−AL, EMC N2, 3
6600, 6650 v2.4.21−28119, 39 FC−SW CLARiiON
AX100
89 IBM xSeries: x235, x255, x360, x440 SuSE SLES [32−Bit] 8 SP4+: PCI−X Emulex LP982−E10, 50 FC−AL, EMC N2, 3
v2.4.21−28119, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
90 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8 SP4+: PCI Emulex: LP101−E9, 10, 50, FC−AL, EMC N
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.4.21−28619, 39, LP1050−E10, 29, 40, LP982−E10, 40 FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
91 IBM xSeries: x225, x335 SuSE SLES [32−Bit] 8 SP4+: PCI Emulex: LP1050−E10, 29, 50, FC−AL, EMC N
v2.4.21−28619, 39, LP982−E10, 50; FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39, QLogic QLA2340−E−SP35, 42
v2.4.21−30919, 39
92 Dell PowerEdge: 1800, 1850, 2800, 2850 SuSE SLES [32−Bit] 8 SP4+: PCI Emulex LP1050Ex−E4, 9, 10, 40 FC−AL, EMC N
v2.4.21−28619, 39, Express FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
93 IBM xSeries: x336 (8837)26, x346 (8840)26 SuSE SLES [32−Bit] 8 SP4+: PCI QLogic QLE2360−E−SP1, 8 FC−AL, EMC N
v2.4.21−28619, 39, Express FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
94 Dell PowerEdge: 1800, 1850, 2800, 2850, 6800, 6850 SuSE SLES [32−Bit] 8 SP4+: PCI Emulex LP101−E9, 10, 50 FC−AL, EMC N
v2.4.21−28619, 39, Express, FC−SW CLARiiON
v2.4.21−30419, 39, PCI−X AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
95 IBM xSeries x336 (8837)26 SuSE SLES [32−Bit] 8 SP4+: PCI IBM 24P0960 (QLA2340)4, 35, 37, 42 ; FC−AL, EMC N
v2.4.21−28619, 39, Express, QLogic QLA2340−E−SP35 FC−SW CLARiiON
v2.4.21−30419, 39, PCI−X AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
96 Dell PowerEdge 2850 SuSE SLES [32−Bit] 8 SP4+: PCI−X Emulex LP101−E9, 10, 40 FC−AL, EMC N
v2.4.21−28619, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39

11/02/2006 153 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
97 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 4600, SuSE SLES [32−Bit] 8 SP4+: PCI−X Emulex LP101−E9, 10, 50 FC−AL, EMC N
6600, 6650 v2.4.21−28619, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
98 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 8 SP4+: PCI−X Emulex LP1050Ex−E4, 10, 12, 50 FC−AL, EMC N
S2 v2.4.21−28619, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
99 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2800, SuSE SLES [32−Bit] 8 SP4+: PCI−X Emulex: LP1050−E10, 29, 40, FC−AL, EMC N
2850, 4600, 6600, 6650 v2.4.21−28619, 39, LP982−E10, 40 FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
100 IBM xSeries: x235, x255, x360, x440 SuSE SLES [32−Bit] 8 SP4+: PCI−X Emulex: LP1050−E10, 29, 50, FC−AL, EMC N
v2.4.21−28619, 39, LP982−E10, 50; FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39, QLogic QLA2340−E−SP35, 42
v2.4.21−30919, 39
101 IBM xSeries x346 (8840)26 SuSE SLES [32−Bit] 8 SP4+: PCI−X IBM 24P0960 (QLA2340)4, 35, 37, 42 FC−AL, EMC N
v2.4.21−28619, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
102 Dell PowerEdge: 2600, 2650, 2850, 4600, 6600, 6650 SuSE SLES [32−Bit] 8 SP4+: PCI−X QLogic QLA200−E−SP41, 42 FC−AL, EMC N
v2.4.21−28619, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
103 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 8 SP4+: PCI−X QLogic QLA2340−E−SP35 FC−AL, EMC N
S2; v2.4.21−28619, 39, FC−SW CLARiiON
v2.4.21−30419, 39, AX100
IBM xSeries x346 (8840)26 v2.4.21−30619, 39,
v2.4.21−30919, 39
104 Dell PowerEdge: 2600, 2650, 2850, 4600, 6600, 6650; SuSE SLES [32−Bit] 8 SP4+: PCI−X QLogic QLA2340−E−SP35, 43 FC−AL, EMC N
v2.4.21−28619, 39, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 v2.4.21−30419, 39, AX100
S2 v2.4.21−30619, 39,
v2.4.21−30919, 39
105 Dell PowerEdge 1850 SuSE SLES [32−Bit] 8 SP4+: PCI, Emulex LP101−E9, 10, 40; FC−AL, EMC N
v2.4.21−28619, 39, PCI−X QLogic: QLA200−E−SP41, 42, FC−SW CLARiiON
v2.4.21−30419, 39, QLA2340−E−SP35, 43 AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
106 Dell PowerEdge: 1800, 1850 SuSE SLES [32−Bit] 8 SP4+: PCI, Emulex: LP1050−E10, 29, 40, FC−AL, EMC N
v2.4.21−28619, 39, PCI−X LP982−E10, 40 FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39,
v2.4.21−30919, 39
107 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8 SP4+: PCI, Emulex: LP1050−E10, 29, 50, FC−AL, EMC N
v2.4.21−28619, 39, PCI−X LP982−E10, 50; FC−SW CLARiiON
v2.4.21−30419, 39, AX100
v2.4.21−30619, 39, QLogic QLA2340−E−SP35, 42
v2.4.21−30919, 39
108 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8: SP3 PCI Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.4.21−13819, SP3+ QLogic: QLA200−E−SP41, FC−SW CLARiiON
v2.4.21−19019 QLA2340−E−SP35, 43 AX100
HPQ Proliant: DL32045, DL360(G2)45, DL36045, DL58045,
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45,
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045,
ML75045;
IBM: Netfinity 4500R, xSeries x225, xSeries x230, xSeries
x232, xSeries x240, xSeries x250, xSeries x330, xSeries
x335, xSeries x340 (4500R), xSeries x342, xSeries x350
(6000R), xSeries x370
109 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, SuSE SLES [32−Bit] 8: SP3 PCI−X Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
4600, 6600, 6650; v2.4.21−13819, SP3+ QLogic QLA2340−E−SP35, 43 FC−SW CLARiiON
v2.4.21−19019 AX100
HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045,
DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries: x235, x255, x360, x365, x440;
Samsung SS3840
110 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2850, SuSE SLES [32−Bit] 8: SP3 PCI−X QLogic QLA200−E−SP41 FC−AL, EMC N2, 3
4600, 6600, 6650; v2.4.21−13819, SP3+ FC−SW CLARiiON
v2.4.21−19019 AX100
HPQ Proliant: BL40p, DL360(G3)45, DL56045, DL74045,
DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries: x235, x255, x360, x365, x440
111 Dell PowerEdge 1850; SuSE SLES [32−Bit] 8: SP3 PCI, Emulex LP101−E9, 10, 67; FC−AL, EMC N2, 3
HPQ Proliant: DL380(G2)45, DL380(G3)45, DL38045, v2.4.21−13819, SP3+ PCI−X QLogic: QLA200−E−SP41, FC−SW CLARiiON
DL580(G2)45, DL580(G3)45, ML370(G3)45; v2.4.21−19019 QLA2340−E−SP35, 43 AX100
IBM xSeries: x345 (8670), x445 (8870)

11/02/2006 154 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
112 Dell PowerEdge: 1550, 1650, 2300, 2400, 2450, 2500, SuSE SLES [32−Bit] 8: SP3 PCI Emulex LP1050−E10, 29, 67 FC−AL, EMC N2, 3
255047, 4300, 4400, 6100, 6300, 6350, 6400, 645089, v2.4.21−13819, SP3+ FC−SW CLARiiON
8450; v2.4.21−19019, SP3+ AX100
v2.4.21−24119, 39
HPQ Netserver LC: 2000 U3, 2000r;
HPQ Netserver LH: (LH Pro), 3, 300088, 4, 6000/LH 6000r,
II, PRO, lll;
HPQ Netserver: LP 2000r, LPR, LT 6000R, LX PRO, LXR
8000, LXR 8500, LXR PRO, LXR PRO8;
HPQ Proliant: 160045, 185045, 250045, 300045, 500045,
550045, 600045, 6400R, 650045, 700045, 800, 800045, 850,
850045, DL32045, DL360(G2)45, DL36045, DL380(G2)45,
DL380(G3)45, DL38045, DL580(G2)45, DL58045,
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45,
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045,
ML75045;
IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20,
5600, 6000R, 7000, 7000 M1090, 7100, 7600, 8500,
8500R;
IBM xSeries: x225, x230, x232, x240, x250, x255, x330,
x335, x340 (4500R), x342, x345 (8670), x350 (6000R),
x370
113 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8: SP3 PCI Emulex LP982−E10, 67 FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.4.21−13819, SP3+ FC−SW CLARiiON
v2.4.21−19019, SP3+ AX100
HPQ Proliant: DL32045, DL360(G2)45, DL36045, DL58045, v2.4.21−24119, 39
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45,
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045,
ML75045;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335,
x342, x350 (6000R), x370
114 Fujitsu Siemens Primergy BX620: S2F14, S214; SuSE SLES [32−Bit] 8: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 35, FC−AL, EMC N2, 3
v2.4.21−13819, SP3+ 63, 74, 77 FC−SW CLARiiON
Fujitsu Siemens Primergy: BX62014, BX66014 v2.4.21−19019, SP3+ AX100
v2.4.21−24119, 39
115 IBM xSeries: x225, x230, x232, x240, x250, x330, x335, SuSE SLES [32−Bit] 8: SP3 PCI IBM 24P0960 (QLA2340)4, 35, 37, 74, FC−AL, EMC N2, 3
x340 (4500R), x342, x350 (6000R), x370 v2.4.21−13819, SP3+ 78 FC−SW CLARiiON
v2.4.21−19019, SP3+ AX100
v2.4.21−24119, 39
116 IBM xSeries: x235, x255, x360, x365, x440 SuSE SLES [32−Bit] 8: SP3 PCI−X IBM 24P0960 (QLA2340)4, 35, 37, 74, FC−AL, EMC N2, 3
v2.4.21−13819, SP3+ 78 FC−SW CLARiiON
v2.4.21−19019, SP3+ AX100
v2.4.21−24119, 39
117 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8: SP3 PCI, IBM 24P0960 (QLA2340)4, 35, 37, 74, FC−AL, EMC N2, 3
v2.4.21−13819, SP3+ PCI−X 78 FC−SW CLARiiON
v2.4.21−19019, SP3+ AX100
v2.4.21−24119, 39
118 Dell PowerEdge 2850 SuSE SLES [32−Bit] 8: SP3 PCI−X QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
v2.4.21−13819, SP3+ FC−SW CLARiiON
v2.4.21−19019, SP3+ AX100
v2.4.21−26619, 39
119 Dell PowerEdge 1850 SuSE SLES [32−Bit] 8: SP3 PCI, QLogic QLA2340−E−SP35, 43, 74 FC−AL, EMC N2, 3
v2.4.21−13819, SP3+ PCI−X FC−SW CLARiiON
v2.4.21−19019, SP3+ AX100
v2.4.21−26619, 39
120 Dell PowerEdge 1850 SuSE SLES [32−Bit] 8: SP3+ PCI, QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
v2.4.21−26619, 39, SP4 PCI−X FC−SW CLARiiON
v2.4.21−27819, 39, SP4+ AX100
v2.4.21−28119, 39, SP4+
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
121 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8: SP4 PCI Emulex: LP1050−E10, 29, 40, FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.4.21−27819, 39, SP4+ LP982−E10, 40 FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
122 IBM xSeries: x225, x335 SuSE SLES [32−Bit] 8: SP4 PCI QLogic QLA2340−E−SP35, 42 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
123 Dell PowerEdge: 1800, 1850, 2800, 2850 SuSE SLES [32−Bit] 8: SP4 PCI Emulex LP1050Ex−E4, 9, 10, 40 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ Express FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
124 IBM xSeries: x336 (8837)26, x346 (8840)26 SuSE SLES [32−Bit] 8: SP4 PCI QLogic QLE2360−E−SP1, 8 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ Express FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
125 Dell PowerEdge: 1800, 1850, 2800, 2850, 6800, 6850 SuSE SLES [32−Bit] 8: SP4 PCI Emulex LP101−E9, 10, 50 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ Express, FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ PCI−X AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39

11/02/2006 155 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
126 IBM xSeries x336 (8837)26 SuSE SLES [32−Bit] 8: SP4 PCI IBM 24P0960 (QLA2340)4, 35, 37, 42 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ Express, FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ PCI−X AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
127 Dell PowerEdge 2850 SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex LP101−E9, 10, 40 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
128 IBM xSeries: x235, x255, x360, x440 SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex LP1050−E10, 29, 50; FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ QLogic QLA2340−E−SP35, 42 FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
129 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex LP1050Ex−E4, 10, 12, 50 FC−AL, EMC N2, 3
S2 v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
130 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 2800, SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex: LP1050−E10, 29, 40, FC−AL, EMC N2, 3
2850, 4600, 6600, 6650 v2.4.21−27819, 39, SP4+ LP982−E10, 40 FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
131 IBM xSeries x346 (8840)26 SuSE SLES [32−Bit] 8: SP4 PCI−X IBM 24P0960 (QLA2340)4, 35, 37, 42 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
132 Dell PowerEdge: 2600, 2650, 2850, 4600, 6600, 6650 SuSE SLES [32−Bit] 8: SP4 PCI−X QLogic QLA200−E−SP41, 42 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
133 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 8: SP4 PCI−X QLogic QLA2340−E−SP35 FC−AL, EMC N2, 3
S2; v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
IBM xSeries x346 (8840)26 v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
134 Dell PowerEdge: 2600, 2650, 2850, 4600, 6600, 6650; SuSE SLES [32−Bit] 8: SP4 PCI−X QLogic QLA2340−E−SP35, 43 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 v2.4.21−28119, 39, SP4+ AX100
S2 v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
135 Dell PowerEdge 1850 SuSE SLES [32−Bit] 8: SP4 PCI, Emulex LP101−E9, 10, 40; FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ PCI−X QLogic QLA200−E−SP41, 42 FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
136 Dell PowerEdge: 1800, 1850 SuSE SLES [32−Bit] 8: SP4 PCI, Emulex: LP1050−E10, 29, 40, FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ PCI−X LP982−E10, 40 FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
137 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8: SP4 PCI, QLogic QLA2340−E−SP35, 42 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ PCI−X FC−SW CLARiiON
v2.4.21−28119, 39, SP4+ AX100
v2.4.21−30419, 39, SP4+
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
138 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 8: SP4 PCI Emulex LP101−E9, 10, 50 FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
IBM xSeries: x225, x335 v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
139 IBM xSeries: x225, x335 SuSE SLES [32−Bit] 8: SP4 PCI Emulex LP982−E10, 50, 72 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
140 Fujitsu Siemens Primergy BX620: S2F14, S214; SuSE SLES [32−Bit] 8: SP4 PCI Fujitsu Siemens BX600−FC22Q4, 35, FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ 42, 63 FC−SW CLARiiON
Fujitsu Siemens Primergy: BX62014, BX66014 v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
141 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, 4600, SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex LP101−E9, 10, 50 FC−AL, EMC N2, 3
6600, 6650; v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
IBM xSeries: x235, x255, x360, x440; v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
Sun: V20z, V40z

11/02/2006 156 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
142 Fujitsu Siemens Primergy: RX200 S2, RX300 S2, TX200 SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex LP101−E10, 12, 50 FC−AL, EMC N2, 3
S2, TX300 S2 v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
143 IBM xSeries: x235, x255, x360, x440 SuSE SLES [32−Bit] 8: SP4 PCI−X Emulex LP982−E10, 50, 72 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
144 Fujitsu Siemens Primergy: RX200, RX200 S2, RX300, SuSE SLES [32−Bit] 8: SP4 PCI−X Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC N2, 3
RX300 S2, TX200, TX200 S2, TX300, TX300 S2 v2.4.21−27819, 39, SP4+ (Emulex LP9802)10, 12, 50, 71, 72 FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
145 IBM xSeries: x345 (8670), x445 (8870) SuSE SLES [32−Bit] 8: SP4 PCI, Emulex: LP101−E9, 10, 50, FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ PCI−X LP982−E10, 50, 72 FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
146 Fujitsu Siemens Primergy: BX300, RX600, RX800, TX600 SuSE SLES [32−Bit] 8: SP4 PCI, Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC N2, 3
v2.4.21−27819, 39, SP4+ PCI−X (Emulex LP9802)10, 12, 50, 71, 72 FC−SW CLARiiON
v2.4.21−30419, 39, SP4+ AX100
v2.4.21−30619, 39, SP4+
v2.4.21−30919, 39
147 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 9 SP1+ PCI Emulex LP101−E4, 9, 10, 11 ; FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.6.5−7.1516, 7 QLogic: QLA200−E−SP4, 5, 41, FC−SW CLARiiON
QLA2340−E−SP5, 35 AX100
HPQ Proliant: DL32045, DL360(G2)45, DL36045,
DL380(G2)45, DL380(G3)45, DL38045, DL580(G2)45,
DL58045, ML350(G2)45, ML350(G3)45, ML35045,
ML370(G2)45, ML37045, ML530(G2)45, ML530(G3)45,
ML53045, ML57045, ML75045;
IBM xSeries: x335, x345 (8670)
148 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 9 SP1+ PCI Emulex: LP1050−E4, 10, 29, 80 , FC−AL, EMC N2, 3
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.6.5−7.1516, 7 LP982−E4, 10, 80; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP4, 5, 35
149 HPQ Proliant: DL32045, DL360(G2)45, DL36045, DL58045, SuSE SLES [32−Bit] 9 SP1+ PCI Emulex: LP1050−E10, 29, 80, FC−AL, EMC N2, 3
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45, v2.6.5−7.1516, 7 LP982−E10, 80 FC−SW CLARiiON
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045, AX100
45
ML750 ;
IBM xSeries x335
150 Dell PowerEdge: 1800, 1850, 2800, 2850, 6800, 6850; SuSE SLES [32−Bit] 9 SP1+ PCI Emulex LP1050Ex−E4, 9, 10, 11 FC−AL, EMC Y
v2.6.5−7.1516, 7 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)26;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
151 Dell PowerEdge: 1800, 1850, 2800, 2850, 6800, 6850; SuSE SLES [32−Bit] 9 SP1+ PCI QLogic QLE2360−E−SP1, 4, 5, 8 FC−AL, EMC Y2, 3
v2.6.5−7.1516, 7 Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; AX100
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)26;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
152 HPQ Proliant ML350(G4)45 SuSE SLES [32−Bit] 9 SP1+ PCI Emulex: LP101−E4, 9, 10, 11 , FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 Express, LP1050−E10, 29, 80, LP982−E10, 80; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA200−E−SP4, 5, 41,
QLA2340−E−SP5, 35
153 Dell PowerEdge 1855 SuSE SLES [32−Bit] 9 SP1+ PCI−X Dell 2342M5, 35 FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 FC−SW CLARiiON
AX100
154 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 9 SP1+ PCI−X Emulex LP101−E4, 9, 10, 11 FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, AX100
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries x235
155 Fujitsu Siemens Primergy: RX200 S2, RX300, RX300 S2, SuSE SLES [32−Bit] 9 SP1+ PCI−X Emulex LP101−E4, 10, 11, 12 FC−AL, EMC N2, 3
RX600 S2, TX200 S2, TX300, TX300 S2, TX600 S2 v2.6.5−7.1516, 7 FC−SW CLARiiON
AX100
156 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 9 SP1+ PCI−X Emulex LP1050Ex−E4, 10, 11, 12 FC−AL, EMC Y
S2 v2.6.5−7.1516, 7 FC−SW CLARiiON
AX100
157 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650 SuSE SLES [32−Bit] 9 SP1+ PCI−X Emulex: LP1050−E4, 10, 29, 80 , FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 LP982−E4, 10, 80 FC−SW CLARiiON
AX100

11/02/2006 157 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
158 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9 SP1+ PCI−X Emulex: LP1050−E10, 29, 80, FC−AL, EMC N2, 3
DL56045, DL760 (G2)45, DL76045, ML570(G2)45; v2.6.5−7.1516, 7 LP982−E10, 80 FC−SW CLARiiON
AX100
IBM xSeries x235
159 Dell PowerEdge: 1600SC, 1650, 1750; SuSE SLES [32−Bit] 9 SP1+ PCI−X QLogic QLA2340−E−SP4, 5, 35 FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 AX100
S2
160 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 9 SP1+ PCI−X QLogic: QLA200−E−SP4, 5, 41, FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 QLA2340−E−SP5, 35 FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, RX300, RX300 S2, AX100
RX600 S2, TX200 S2, TX300, TX300 S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45,
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45;
IBM xSeries x235
161 Fujitsu Siemens Primergy: RX600, TX600 SuSE SLES [32−Bit] 9 SP1+ PCI, Emulex LP101−E4, 10, 11, 12 FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 PCI−X FC−SW CLARiiON
AX100
162 Samsung ES470 SuSE SLES [32−Bit] 9 SP1+ PCI, Emulex: LP101−E4, 9, 10, 11 , FC−AL, EMC Y2, 3
v2.6.5−7.1516, 7 PCI−X LP1050−E4, 10, 11, 29 , LP982−E4, 10, FC−SW CLARiiON
11; AX100
QLogic QLA2340−E−SP4, 5, 35
163 HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, SuSE SLES [32−Bit] 9 SP1+ PCI, Emulex: LP101−E4, 9, 10, 11 , FC−AL, EMC N2, 3
DL380(G4)45, DL38045, DL38545, DL580(G2)45, v2.6.5−7.1516, 7 PCI−X LP1050−E10, 29, 80, LP982−E10, 80 FC−SW CLARiiON
DL580(G3)45, DL58545, ML370(G3)45, ML370(G4)45; AX100
IBM xSeries x345 (8670)
164 Fujitsu Siemens Primergy: RX600, TX600; SuSE SLES [32−Bit] 9 SP1+ PCI, QLogic QLA200−E−SP4, 5, 41 FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, AX100
DL380(G4)45, DL38045, DL38545, DL580(G2)45,
DL580(G3)45, DL58545, ML370(G3)45, ML370(G4)45;
IBM xSeries x345 (8670)
165 Fujitsu Siemens Primergy: RX600, TX600; SuSE SLES [32−Bit] 9 SP1+ PCI, QLogic QLA2340−E−SP5, 35 FC−AL, EMC N2, 3
v2.6.5−7.1516, 7 PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL380(G4)45, DL38545, AX100
DL580(G2)45, DL580(G3)45, DL58545, ML370(G3)45,
ML370(G4)45
166 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LP101−E4, 9, 10, 79 ; FC−AL, EMC Y2, 31
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP4, 33, 41, FC−SW CLARiiON
QLA210−E−SP4, 33, 41, AX100
HPQ Proliant: DL32045, DL360(G2)45, DL36045, QLA2340−E−SP33, 35
DL380(G2)45, DL380(G3)45, DL38045, DL580(G2)45,
DL58045, ML350(G2)45, ML350(G3)45, ML35045,
ML370(G2)45, ML37045, ML530(G2)45, ML530(G3)45,
ML53045, ML57045, ML75045
167 Fujitsu Siemens Primergy BX620: S2F14, S214; SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LP1050−E4, 10, 12, 15 FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
Fujitsu Siemens Primergy BX630: (2−way), (4−way) AX100
168 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050−E4, 10, 29, 79 , FC−AL, EMC Y2, 31
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.6.5−7.201, v2.6.5−7.202.7 LP982−E4, 10, 79; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP4, 33, 35
169 HPQ Proliant: DL32045, DL360(G2)45, DL36045, DL58045, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050−E10, 29, 79, FC−AL, EMC Y2, 31
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45, v2.6.5−7.201, v2.6.5−7.202.7 LP982−E10, 79 FC−SW CLARiiON
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045, AX100
ML75045
170 Fujitsu Siemens Primergy BX620: S2F14, S214; SuSE SLES [32−Bit] 9 SP2+: PCI Fujitsu Siemens BX600−FC22Q4, 35, FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 63, 73 FC−SW CLARiiON
Fujitsu Siemens Primergy: BX62014, BX630 (2−way), AX100
BX630 (4−way)
171 HPQ Proliant: DL32045, DL360(G2)45, DL36045, SuSE SLES [32−Bit] 9 SP2+: PCI HPQ AD167A/FC2143 (LP1150)4, FC−AL, EMC Y2, 31
DL380(G2)45, DL380(G3)45, DL38045, DL580(G2)45, v2.6.5−7.201, v2.6.5−7.202.7 10, 60, 62 FC−SW CLARiiON
DL58045, ML350(G2)45, ML350(G3)45, ML35045, AX100
ML370(G2)45, ML37045, ML530(G2)45, ML530(G3)45,
ML53045, ML57045, ML75045
172 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LP1050Ex−E4, 9, 10, 62 ; FC−AL, EMC Y2, 31
6850; v2.6.5−7.201, v2.6.5−7.202.7 Express QLogic QLE2360−E−SP1, 4, 8, 33 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)26;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
173 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LPe111−E4, 10, 15, 18 FC−AL, EMC Y2, 31
6850; v2.6.5−7.201, v2.6.5−7.202.7 Express FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)45, DL380(G4)45, ML350(G4)45,
ML370(G4)45;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 158 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
174 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LPe1150−E4, 10, 28, 30 ; FC−AL, EMC Y2, 31
6850; v2.6.5−7.201, v2.6.5−7.202.7 Express QLogic QLE2460−E−SP4, 32, 33 FC−SW CLARiiON
AX100
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
175 HPQ Proliant: DL360(G4)45, DL380(G4)45, ML350(G4)45, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LPe1150−E4, 10, 28, 79 ; FC−AL, EMC Y2, 31
ML370(G4)45 v2.6.5−7.201, v2.6.5−7.202.7 Express HPQ: A8002A/FC2142SR FC−SW CLARiiON
(LPe1150)4, 10, 57, 62 , AX100
AD167A/FC2143 (LP1150)4, 10, 60,
62

176 Dell PowerEdge: 2900, 2950, 6950 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP101−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050−E4, 10, 29, 62 , LP982−E4, 10, FC−SW CLARiiON
PCI−X 62 ; AX100
QLogic QLA2340−E−SP4, 33, 35
177 HPQ Proliant ML350(G4)45 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP101−E4, 9, 10, 79 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050−E10, 29, 79, LP982−E10, 79; FC−SW CLARiiON
PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)4,
33, 44, AD167A/FC2143 (LP1150)4,
10, 60, 62 , AE369A/FC1243
(QLA2462)4, 33, 44;
QLogic: QLA200−E−SP4, 33, 41,
QLA210−E−SP4, 33, 41,
QLA2340−E−SP33, 35
178 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe111−E4, 10, 15, 18 , LPe1150−E4, FC−SW CLARiiON
IBM eServer 326m (Model 7969) PCI−X 10, 28, 30 ; AX100
QLogic: QLE2360−E−SP1, 4, 8, 33,
QLE2460−E−SP4, 32, 33
179 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E4, 10, 12, 62 , FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe1150−E4, 10, 15, 28 FC−SW CLARiiON
PCI−X AX100
180 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E4, 10, 62, FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe1150−E4, 10, 28, LPe1150−E4, FC−SW CLARiiON
PCI−X 10, 28, 79 AX100
181 Dell PowerEdge 1855; SuSE SLES [32−Bit] 9 SP2+: PCI−X Dell 2342M33, 35 FC−AL, EMC Y2, 31
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
182 Dell PowerEdge 1855 SuSE SLES [32−Bit] 9 SP2+: PCI−X Dell: LPe1105−M4, 10, 28, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 QME24624, 33, 59 FC−SW CLARiiON
AX100
183 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E4, 9, 10, 79 ; FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP4, 33, 41, FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, QLA210−E−SP4, 33, 41, AX100
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45 QLA2340−E−SP33, 35
184 Fujitsu Siemens Primergy: RX300, RX300 S2, TX200 S2, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E4, 10, 12, 15 ; FC−AL, EMC Y
TX300, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP4, 41, 70, FC−SW CLARiiON
QLA210−E−SP4, 33, 41 AX100
185 Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E10, 12, 15 FC−AL, EMC Y
S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
186 Fujitsu Siemens Primergy: RX200, RX200 S2, RX300, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050−E4, 10, 12, 15 FC−AL, EMC Y
RX300 S2, TX200, TX200 S2, TX300, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
187 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050−E10, 29, 79 FC−AL, EMC Y2, 31
DL56045, DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
188 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050Ex−E4, 10, 12, 62 FC−AL, EMC Y
S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
189 HPQ Proliant DL760 (G2)45 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP982−E10 FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
190 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP982−E10, 79 FC−AL, EMC Y2, 31
DL56045, DL76045, ML570(G2)45 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
191 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LPe1150−E4, 10, 15, 28 FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
192 Dell PowerEdge: 6800, 6850; SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex: LP101−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 LP1050−E4, 10, 29, 62 , LP982−E4, 10, FC−SW CLARiiON
Digital Henge SH4500R4; 62 AX100
IBM xSeries: x336 (8837)26, x346 (8840)26, x3850/x366
(8863)65, 66;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230

11/02/2006 159 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
193 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex: LP1050−E4, 10, 29, 79 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 LP982−E4, 10, 79 FC−SW CLARiiON
AX100
194 Fujitsu Siemens Primergy: RX200, RX300, RX300 S2, SuSE SLES [32−Bit] 9 SP2+: PCI−X Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC Y
TX200, TX200 S2, TX300, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7 (Emulex: LP9802)10, 12, LP9802)10, FC−SW CLARiiON
12, 71, 72 AX100
195 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9 SP2+: PCI−X HPQ AD167A/FC2143 (LP1150)4, FC−AL, EMC Y2, 31
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.201, v2.6.5−7.202.7 10, 60, 62 FC−SW CLARiiON
AX100
196 HPQ Proliant DL360(G4)45 SuSE SLES [32−Bit] 9 SP2+: PCI−X HPQ: AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 33, 44, AE369A/FC1243 (QLA2462)4, FC−SW CLARiiON
33, 44 AX100
197 Dell PowerEdge: 1600SC, 1650, 1750, 6800, 6850; SuSE SLES [32−Bit] 9 SP2+: PCI−X QLogic QLA2340−E−SP4, 33, 35 FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
Digital Henge SH4500R4; AX100
IBM xSeries: x336 (8837)26, x346 (8840)26, x3850/x366
(8863)65, 66;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230
198 Fujitsu Siemens Primergy: RX200, RX200 S2, RX600 S2, SuSE SLES [32−Bit] 9 SP2+: PCI−X QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
TX200, TX600 S2 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
199 IBM xSeries: x3800/x260 (8865)65, 66, x3950/x3950E/x460 SuSE SLES [32−Bit] 9 SP2+: PCI−X64 Emulex: LP101−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
(8872, 8874)65, 66 v2.6.5−7.201, v2.6.5−7.202.7 LP1050−E4, 10, 29, 62 , LP982−E4, 10, FC−SW CLARiiON
62; AX100
QLogic QLA2340−E−SP4, 33, 35
200 Dell PowerEdge 1955 SuSE SLES [32−Bit] 9 SP2+: PCI, PCI Dell: LPe1105−M4, 10, 28, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 Express, QME24624, 33, 59 FC−SW CLARiiON
PCI−X AX100
201 Fujitsu Siemens Primergy: RX600, TX600 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex LP101−E4, 10, 12, 15 ; FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X Fujitsu Siemens S26361−F2843−E1 FC−SW CLARiiON
(Emulex: LP9802) 10, 12 , LP9802)10, AX100
12, 71, 72 ;

QLogic: QLA200−E−SP4, 41, 70,


QLA210−E−SP4, 33, 41,
QLA2340−E−SP35
202 Fujitsu Siemens Primergy: RX600, RX800 S2, TX600 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex LP1050−E4, 10, 12, 15 FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
AX100
203 HPQ Proliant DL38045 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex LP982−E10 FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
AX100
204 HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex LP982−E10, 79 FC−AL, EMC Y2, 31
DL380(G4)45, DL38545, DL580(G2)45, DL58545, v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
ML370(G3)45, ML370(G4)45 AX100
205 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850; SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E4, 9, 10, 62 , FC−AL, EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP1050−E4, 10, 29, 62 , LP982−E4, 10, FC−SW CLARiiON
Samsung: ES470, ES570, SS140 62; AX100
QLogic QLA2340−E−SP4, 33, 35
206 HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E4, 9, 10, 79 , FC−AL, EMC Y2, 31
DL380(G4)45, DL38045, DL38545, DL580(G2)45, DL58545, v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP1050−E10, 29, 79; FC−SW CLARiiON
ML370(G3)45, ML370(G4)45 AX100
HPQ AD167A/FC2143 (LP1150)4,
10, 60, 62 ;
QLogic: QLA200−E−SP4, 33, 41,
QLA210−E−SP4, 33, 41
207 Fujitsu Siemens Primergy RX800 SuSE SLES [32−Bit] 9 SP2+: PCI, Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X (Emulex: LP9802)10, 12, 62, FC−SW CLARiiON
LP9802)10, 12, 62, 71, 72 ; AX100
QLogic QLA2340−E−SP4, 35
208 HPQ Proliant: DL380(G4)45, DL38545, DL58545, SuSE SLES [32−Bit] 9 SP2+: PCI, HPQ: AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y2, 31
ML370(G4)45 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X 33, 44, AE369A/FC1243 (QLA2462)4, FC−SW CLARiiON
33, 44 AX100
209 HPQ Proliant: DL14545, DL380(G4)45, DL38545, SuSE SLES [32−Bit] 9 SP2+: PCI, QLogic QLA2340−E−SP33, 35 FC−AL, EMC Y2, 31
DL580(G2)45, DL58545, ML370(G3)45, ML370(G4)45 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
AX100
210 Fujitsu Siemens Primergy RX800 S2 SuSE SLES [32−Bit] 9 SP2+: PCI, QLogic: QLA2340−E−SP4, 33, 35, FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X QLA2340−E−SP33, 35 FC−SW CLARiiON
AX100
211 Fujitsu Siemens Primergy: RX300, RX300 S2, TX200 S2, SuSE SLES [32−Bit] 9 SP2+: PCI−X QLogic QLA2340−E−SP35 FC−AL, EMC Y
TX300, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7; FC−SW CLARiiON
AX100
SuSE SLES [32−Bit] 9: SP3
v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 160 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
212 HPQ Proliant DL580(G3)45 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LPe111−E4, 10, 15, 18 , FC−AL, EMC Y2, 31
v2.6.5−7.2016, 19, 20, Express LPe1150−E4, 10, 28, 79 ; FC−SW CLARiiON
v2.6.5−7.202.7 AX100
HPQ: A8002A/FC2142SR
(LPe1150)4, 10, 57, 62 ,
AD167A/FC2143 (LP1150)4, 10, 60,
62

213 HPQ Proliant DL580(G3)45 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E4, 9, 10, 79 , FC−AL, EMC Y2, 31
v2.6.5−7.2016, 19, 20, PCI−X LP1050−E10, 29, 79, LP982−E10, 79; FC−SW CLARiiON
v2.6.5−7.202.7 AX100
HPQ AD167A/FC2143 (LP1150)4,
10, 60, 62 ;
QLogic: QLA200−E−SP4, 33, 41,
QLA210−E−SP4, 33, 41,
QLA2340−E−SP33, 35
214 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9 SP3: PCI Unisys: FCH732213−P64 FC−AL, EMC Y
ES7000/540 v2.6.5−7.244, v2.6.5−7.2446, (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
19, 20; FCH742313−P64 (LP9802)9, 10, 13, AX100
FCH752313−PCX (LP1050)9, 10, 13
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
215 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9 SP3: PCI QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, Express FC−SW CLARiiON
19, 20; AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
216 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP3: PCI Emulex LP1050Ex−E4, 10, 13 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, Express, FC−SW CLARiiON
19, 20; PCI−X AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
217 Fujitsu Siemens Primergy: RX200 S3, RX220, RX600 S3, SuSE SLES [32−Bit] 9 SP3: PCI QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
TX300 S3, TX600 S3 v2.6.5−7.244, v2.6.5−7.2446, Express, FC−SW CLARiiON
19, 20; PCI−X AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
218 Fujitsu Siemens Primergy TX200 S3 SuSE SLES [32−Bit] 9 SP3: PCI, PCI QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, Express, FC−SW CLARiiON
19, 20; PCI−X AX100
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
219 Unisys ES7000/460 [32−Bit] SuSE SLES [32−Bit] 9 SP3: PCI, Unisys: FCH732213−P64 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2446, PCI−X (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
19, 20; FCH742313−P64 (LP9802)9, 10, 13, AX100
FCH752313−PCX (LP1050)9, 10, 13
SuSE SLES [32−Bit] 9 SP3+:
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
220 Fujitsu Siemens Primergy BX620: S2F14, S214 SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050−E4, 10, 12, 13 FC−AL, EMC Y
v2.6.5−7.244, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
221 Fujitsu Siemens Primergy BX620: S2F14, S214, S3; SuSE SLES [32−Bit] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 35, FC−AL, EMC Y
v2.6.5−7.244, SP3+ 63 FC−SW CLARiiON
Fujitsu Siemens Primergy: BX62014, BX630 (8−way) v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
222 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9: SP3 PCI Unisys: FCH732213−P64 FC−AL, EMC Y36
ES7000/540 v2.6.5−7.244, SP3+ (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
v2.6.5−7.252, SP3+ FCH742313−P64 (LP9802)9, 10, 13, AX100
v2.6.5−7.257, SP3+ FCH752313−PCX (LP1050)9, 10, 13
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
223 IBM xSeries x3455 (7984) SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 9, 10, 13 ; FC−AL, EMC Y, Y36
v2.6.5−7.244, SP3+ Express IBM: 42C2069 (LPe11000)4, 10, 13, FC−SW CLARiiON
v2.6.5−7.252, SP3+ 57, 42C2071 (LPe11002)4, 10, 13, 57 ; AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+ QLogic: QLE2360−E−SP1, 4, 34,
v2.6.5−7.276, SP3+ QLE2460−E−SP4, 32, 34
v2.6.5−7.282
224 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y2, 31,
(407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express HBA for HP c−Class Bladesystem FC−SW CLARiiON Y23
v2.6.5−7.252, SP3+ (403621−B21)13, 21, 22 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 161 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
225 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
v2.6.5−7.252, SP3+ (403619−B21)34, 46 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
226 HPQ Proliant BL465c: (403433−B21), (403434−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
v2.6.5−7.252, SP3+ (403621−B21)13, 21, 22, QLogic AX100
v2.6.5−7.257, SP3+ QMH2462 4Gb FC HBA for HP
v2.6.5−7.267, SP3+ c−Class Bladesystem
v2.6.5−7.276, SP3+ (403619−B21)34, 46
v2.6.5−7.282
227 Dell PowerEdge 1950 SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLE220−E−SP4, 16, 17 FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
228 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9: SP3 PCI QLogic: QLA2340−E−SP4, 34, 35, FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express QLA2340−E−SP34, 35, FC−SW CLARiiON
v2.6.5−7.252, SP3+ QLA2340−E−SP35 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
229 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 9, 10, 13 ; FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express, IBM: 24P0960 (QLA2340)4, 35, 37, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 87, 24P8053 (QLA2342)4, 35, 87, AX100
v2.6.5−7.257, SP3+ 39M5894 (QLA2460)4, 32, 34,
v2.6.5−7.267, SP3+ 39M5895 (QLA2462)4, 32, 34;
v2.6.5−7.276, SP3+
v2.6.5−7.282 QLogic: QLA2460−E−SP4, 32, 34,
QLE2360−E−SP1, 4, 34,
QLE2460−E−SP4, 32, 34
230 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 10, 13 FC−AL, EMC Y36
v2.6.5−7.244, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
231 Fujitsu Siemens Primergy RX220; SuSE SLES [32−Bit] 9: SP3 PCI Emulex LPe1150−E4, 10, 13, 28 ; FC−AL, EMC Y36
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ Express, QLogic QLA2340−E−SP4, 34, 35 FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
232 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050−E4, 10, 13, 29 , FC−AL, EMC Y36
v2.6.5−7.244, SP3+ Express, LP1050Ex−E4, 9, 10, 13 , LP1150−E4, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 10, 13, 38 , LP982−E4, 10, 13, AX100
v2.6.5−7.257, SP3+ LPe111−E4, 10, 13, 18 ;
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ IBM: 24P0960 (QLA2340)4, 34, 35,
v2.6.5−7.282 37, 24P8053 (QLA2342)4, 34, 35,
39M5894 (QLA2460)4, 32, 34,
39M5895 (QLA2462)4, 32, 34;
QLogic: QLA2460−E−SP4, 32, 34,
QLE2360−E−SP1, 4, 34,
QLE2460−E−SP4, 32, 34
233 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLE220−E−SP4, 16, 17 FC−AL, EMC Y
6850, 6950; v2.6.5−7.244, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
Intel: SR1500/S5000PAL, SR2500/S5000PAL v2.6.5−7.276, SP3+
v2.6.5−7.282
234 Fujitsu Siemens Primergy: RX200 S3, RX220, RX600 S3, SuSE SLES [32−Bit] 9: SP3 PCI QLogic: QLA2340−E−SP4, 34, 35, FC−AL, EMC Y
TX300 S3, TX600 S3 v2.6.5−7.244, SP3+ Express, QLA2340−E−SP34, 35, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X QLA2340−E−SP35 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
235 Fujitsu Siemens Primergy: RX300, RX300 S2, TX200 S2, SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP101−E4, 10, 12; FC−AL, EMC Y
TX300, TX300 S2 v2.6.5−7.244, SP3+ QLogic: QLA200−E−SP4, 34, 41, FC−SW CLARiiON
v2.6.5−7.252, SP3+ QLA210−E−SP4, 34, 41, AX100
v2.6.5−7.257, SP3+ QLE220−E−SP4, 16, 17, 56
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
236 Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP101−E10, 12 FC−AL, EMC Y
S2 v2.6.5−7.244, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
237 Fujitsu Siemens Primergy: RX200, RX300, RX300 S2, SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP1050−E4, 10, 12, 13 ; FC−AL, EMC Y
TX200, TX200 S2, TX300, TX300 S2 v2.6.5−7.244, SP3+ Fujitsu Siemens S26361−F2843−E1 FC−SW CLARiiON
v2.6.5−7.252, SP3+ (Emulex: LP9802)10, 12, 68, AX100
v2.6.5−7.257, SP3+ LP9802)10, 12, 68, 71, 72
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 162 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
238 HPQ Proliant BL460c: (416653−B21), (416654−B21), SuSE SLES [32−Bit] 9: SP3 PCI−X HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y2, 31
(416655−B21), (416656−B21), (432636−B21); v2.6.5−7.244, SP3+ HBA for HP c−Class Bladesystem FC−SW CLARiiON
v2.6.5−7.252, SP3+ (403621−B21)13, 18, 95 AX100
HPQ Proliant BL480c: (416666−B21), (416667−B21), v2.6.5−7.257, SP3+
(416668−B21), (416669−B21) v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
239 HPQ Proliant BL460c: (416653−B21), (416654−B21), SuSE SLES [32−Bit] 9: SP3 PCI−X HPQ QLogic QMH2462 4Gb FC FC−AL, EMC N
(416655−B21), (416656−B21), (432636−B21); v2.6.5−7.244, SP3+ HBA for HP c−Class Bladesystem FC−SW CLARiiON
v2.6.5−7.252, SP3+ (403619−B21)46, 87 AX100
HPQ Proliant BL480c: (416666−B21), (416667−B21), v2.6.5−7.257, SP3+
(416668−B21), (416669−B21) v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
240 Fujitsu Siemens Primergy: RX200, TX200 SuSE SLES [32−Bit] 9: SP3 PCI−X QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
v2.6.5−7.244, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
241 Dell PowerEdge: 1800, 2800 SuSE SLES [32−Bit] 9: SP3 PCI, PCI QLogic QLE220−E−SP4, 16, 17 FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
242 Fujitsu Siemens Primergy TX200 S3 SuSE SLES [32−Bit] 9: SP3 PCI, PCI QLogic: QLA2340−E−SP4, 34, 35, FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express, QLA2340−E−SP34, 35, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X QLA2340−E−SP35 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
243 Fujitsu Siemens Primergy: RX600, TX600 SuSE SLES [32−Bit] 9: SP3 PCI, Emulex LP101−E4, 10, 12; FC−AL, EMC Y
v2.6.5−7.244, SP3+ PCI−X QLogic: QLA200−E−SP4, 34, 41, FC−SW CLARiiON
v2.6.5−7.252, SP3+ QLA210−E−SP4, 34, 41, AX100
v2.6.5−7.257, SP3+ QLE220−E−SP4, 16, 17, 56
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
244 Fujitsu Siemens Primergy: RX600, RX800 S2, TX600 SuSE SLES [32−Bit] 9: SP3 PCI, Emulex LP1050−E4, 10, 12, 13 ; FC−AL, EMC Y
v2.6.5−7.244, SP3+ PCI−X QLogic QLA2340−E−SP35 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
245 Fujitsu Siemens Primergy: RX600, RX800, TX600 SuSE SLES [32−Bit] 9: SP3 PCI, Fujitsu Siemens S26361−F2843−E1 FC−AL, EMC Y
v2.6.5−7.244, SP3+ PCI−X (Emulex: LP9802)10, 12, 68, FC−SW CLARiiON
v2.6.5−7.252, SP3+ LP9802)10, 12, 68, 71, 72 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
246 Fujitsu Siemens Primergy: RX800, RX800 S2 SuSE SLES [32−Bit] 9: SP3 PCI, QLogic QLA2340−E−SP4, 35 FC−AL, EMC Y
v2.6.5−7.244, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
247 Fujitsu Siemens Primergy RX800 S2 SuSE SLES [32−Bit] 9: SP3 PCI, QLogic: QLA2340−E−SP4, 34, 35, FC−AL, EMC Y
v2.6.5−7.244, SP3+ PCI−X QLA2340−E−SP34, 35 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
248 Unisys ES7000/460 [32−Bit] SuSE SLES [32−Bit] 9: SP3 PCI, Unisys: FCH732213−P64 FC−AL, EMC Y36
v2.6.5−7.244, SP3+ PCI−X (LP9002L−F2)10, 13, 61, FC−SW CLARiiON
v2.6.5−7.252, SP3+ FCH742313−P64 (LP9802)9, 10, 13, AX100
v2.6.5−7.257, SP3+ FCH752313−PCX (LP1050)9, 10, 13
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
249 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP101−E4, 9, 10, 13 ; FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; v2.6.5−7.2446, 19, 20, SP3+ QLogic: QLA200−E−SP4, 34, 41, FC−SW CLARiiON
v2.6.5−7.252, SP3+ QLA210−E−SP4, 34, 41, AX100
HPQ Proliant: DL32045, DL360(G2)45, DL36045, v2.6.5−7.257, SP3+ QLA2340−E−SP34, 35
DL380(G2)45, DL380(G3)45, DL38045, DL580(G2)45, v2.6.5−7.267, SP3+
DL58045, ML350(G2)45, ML350(G3)45, ML35045, v2.6.5−7.276, SP3+
ML370(G2)45, ML37045, ML530(G2)45, ML530(G3)45, v2.6.5−7.282
ML53045, ML57045, ML75045
250 Fujitsu Siemens Primergy BX630: (2−way), (4−way) SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050−E4, 10, 12, 13 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
251 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255047, SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050−E4, 10, 13, 29 , FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 v2.6.5−7.2446, 19, 20, SP3+ LP982−E4, 10; FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+ QLogic QLA2340−E−SP4, 34, 35
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 163 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
252 HPQ Proliant: DL32045, DL360(G2)45, DL36045, DL58045, SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050−E10, 13, 29, FC−AL, EMC Y
ML350(G2)45, ML350(G3)45, ML35045, ML370(G2)45, v2.6.5−7.2446, 19, 20, SP3+ LP982−E10 FC−SW CLARiiON
ML37045, ML530(G2)45, ML530(G3)45, ML53045, ML57045, v2.6.5−7.252, SP3+ AX100
ML75045 v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
253 Fujitsu Siemens Primergy: BX620 S3, BX630 (2−way), SuSE SLES [32−Bit] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 34, FC−AL, EMC Y
BX630 (4−way), BX630 (8−way) v2.6.5−7.2446, 19, 20, SP3+ 35, 63 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
254 HPQ Proliant: DL32045, DL360(G2)45, DL36045, SuSE SLES [32−Bit] 9: SP3 PCI HPQ AD167A/FC2143 (LP1150)4, FC−AL, EMC Y
DL380(G2)45, DL380(G3)45, DL38045, DL580(G2)45, v2.6.5−7.2446, 19, 20, SP3+ 10, 13, 60 ; FC−SW CLARiiON
DL58045, ML350(G2)45, ML350(G3)45, ML35045, v2.6.5−7.252, SP3+ QLogic QLE220−E−SP4, 16, 17, 56 AX100
ML370(G2)45, ML37045, ML530(G2)45, ML530(G3)45, v2.6.5−7.257, SP3+
ML53045, ML57045, ML75045 v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
255 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 9, 10, 13 ; FC−AL, EMC Y
6850; v2.6.5−7.2446, 19, 20, SP3+ Express QLogic QLE2360−E−SP1, 4, 8, 34 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
Digital Henge INNO: HR−4850, HR−6850; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
Digital Henge Revo: JS1400, JS2400; v2.6.5−7.276, SP3+
v2.6.5−7.282
IBM xSeries x336 (8837)26;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
256 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 10, 12, 68 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
257 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9: SP3 PCI Emulex LPe111−E4, 10, 13, 18 FC−AL, EMC Y
6850; v2.6.5−7.2446, 19, 20, SP3+ Express FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
Digital Henge INNO: HR−4850, HR−6850; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
Digital Henge Revo: JS1400, JS2400; v2.6.5−7.276, SP3+
v2.6.5−7.282
HPQ Proliant: DL360(G4)45, DL380(G4)45, DL580(G3)45,
ML350(G4)45, ML370(G4)45;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
258 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9: SP3 PCI Emulex LPe1150−E4, 10, 13, 28 FC−AL, EMC Y
6850; v2.6.5−7.2446, 19, 20, SP3+ Express FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
Digital Henge INNO: HR−4850, HR−6850; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
Digital Henge Revo: JS1400, JS2400; v2.6.5−7.276, SP3+
v2.6.5−7.282
Fujitsu Siemens Primergy RX300 S3;
HPQ Proliant: DL360(G4)45, DL380(G4)45, DL580(G3)45,
ML350(G4)45, ML370(G4)45;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
259 HPQ Proliant: DL360(G4)45, DL380(G4)45, DL580(G3)45, SuSE SLES [32−Bit] 9: SP3 PCI HPQ: A8002A/FC2142SR FC−AL, EMC Y
ML350(G4)45, ML370(G4)45 v2.6.5−7.2446, 19, 20, SP3+ Express (LPe1150)4, 10, 13, 57 , FC−SW CLARiiON
v2.6.5−7.252, SP3+ AD167A/FC2143 (LP1150)4, 10, 13, AX100
v2.6.5−7.257, SP3+ 60
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
260 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLE2460−E−SP4, 32, 34 FC−AL, EMC Y
6850; v2.6.5−7.2446, 19, 20, SP3+ Express FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
Digital Henge INNO: HR−4850, HR−6850; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
Digital Henge Revo: JS1400, JS2400; v2.6.5−7.276, SP3+
v2.6.5−7.282
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
261 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP101−E4, 9, 10, 13 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
HPQ Proliant ML350(G4)45; v2.6.5−7.267, SP3+
Intel: SR1500/S5000PAL, SR2500/S5000PAL v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 164 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
262 Fujitsu Siemens Primergy: RX220, RX600 S3, TX300 S3, SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E4, 10, 12, 68 FC−AL, EMC Y
TX600 S3 v2.6.5−7.2446, 19, 20, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
263 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9: SP3 PCI Emulex LPe1150−E4, 10, 13, 28 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
Fujitsu Siemens Primergy: RX200 S3, RX220, RX600 S3, v2.6.5−7.267, SP3+
TX300 S3, TX600 S3; v2.6.5−7.276, SP3+
v2.6.5−7.282
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
264 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050−E4, 10, 13, 29 , FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, LP982−E4, 10, 13 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
Intel: SR1500/S5000PAL, SR2500/S5000PAL v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
265 HPQ Proliant ML350(G4)45 SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050−E10, 13, 29, FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, LP982−E10; FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+ HPQ: AB429A/FC1143 (QLA2460)4,
v2.6.5−7.267, SP3+ 34, 44, AD167A/FC2143 (LP1150)4,
v2.6.5−7.276, SP3+ 10, 13, 60 , AE369A/FC1243
v2.6.5−7.282 (QLA2462)4, 34, 44;
QLogic: QLA200−E−SP4, 34, 41,
QLA210−E−SP4, 34, 41,
QLE220−E−SP4, 16, 17, 56
266 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050Ex−E4, 9, 10, 13 , FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, LPe111−E4, 10, 13, 18 ; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+ QLogic: QLE2360−E−SP1, 4, 8, 34,
IBM eServer 326m (Model 7969); v2.6.5−7.267, SP3+ QLE2460−E−SP4, 32, 34
Intel: SR1500/S5000PAL, SR2500/S5000PAL v2.6.5−7.276, SP3+
v2.6.5−7.282
267 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLA2340−E−SP4, 34, 35 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
Fujitsu Siemens Primergy RX220; v2.6.5−7.267, SP3+
Intel: SR1500/S5000PAL, SR2500/S5000PAL v2.6.5−7.276, SP3+
v2.6.5−7.282
268 Fujitsu Siemens Primergy RX220; SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLA2340−E−SP34, 35 FC−AL, EMC Y
HPQ Proliant ML350(G4)45 v2.6.5−7.2446, 19, 20, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
269 Dell PowerEdge 1855; SuSE SLES [32−Bit] 9: SP3 PCI−X Dell 2342M34, 35 FC−AL, EMC Y
Unisys ES3105 v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
270 Dell PowerEdge 1855 SuSE SLES [32−Bit] 9: SP3 PCI−X Dell: LPe1105−M4, 10, 13, 28 , FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ QME24624, 34, 59 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
271 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650, SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP101−E4, 9, 10, 13 FC−AL, EMC Y
6800, 6850; v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
Digital Henge SH4500R4; v2.6.5−7.257, SP3+
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, v2.6.5−7.267, SP3+
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45; v2.6.5−7.276, SP3+
v2.6.5−7.282
IBM xSeries: x336 (8837)26, x346 (8840)26;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230
272 Fujitsu Siemens Primergy RX200 S2 SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP1050−E4, 10, 12, 13 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 165 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
273 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650, SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP1050−E4, 10, 13, 29 FC−AL, EMC Y
6800, 6850; v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
Digital Henge SH4500R4; v2.6.5−7.257, SP3+
IBM xSeries: x336 (8837)26, x346 (8840)26; v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
LangChao: NC2000, NC3000, NC3500, NF420, NF500, v2.6.5−7.282
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230
274 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP1050−E10, 13, 29 FC−AL, EMC Y
DL56045, DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
275 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, TX600 SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP1050Ex−E4, 10, 12, 68 ; FC−AL, EMC Y
S2 v2.6.5−7.2446, 19, 20, SP3+ QLogic QLA2340−E−SP4, 35 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
276 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650 SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP982−E4, 10 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
277 Dell PowerEdge: 6800, 6850; SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP982−E4, 10, 13 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.252, SP3+ AX100
IBM xSeries: x336 (8837)26, x346 (8840)26; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
LangChao: NC2000, NC3000, NC3500, NF420, NF500, v2.6.5−7.276, SP3+
NF520; v2.6.5−7.282
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230
278 HPQ Proliant: DL360(G3)45, DL360(G4)45, DL56045, SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP982−E10 FC−AL, EMC Y
DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
279 HPQ Proliant BL40p SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LP982−E10, 13 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
280 Fujitsu Siemens Primergy: RX600 S2, TX600 S2 SuSE SLES [32−Bit] 9: SP3 PCI−X Emulex LPe1150−E4, 10, 13, 28 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
281 HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, SuSE SLES [32−Bit] 9: SP3 PCI−X HPQ AD167A/FC2143 (LP1150)4, FC−AL, EMC Y
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.2446, 19, 20, SP3+ 10, 13, 60 ; FC−SW CLARiiON
v2.6.5−7.252, SP3+ QLogic QLE220−E−SP4, 16, 17, 56 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
282 HPQ Proliant DL360(G4)45 SuSE SLES [32−Bit] 9: SP3 PCI−X HPQ: AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ 34, 44, AE369A/FC1243 (QLA2462)4, FC−SW CLARiiON
v2.6.5−7.252, SP3+ 34, 44 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
283 Dell PowerEdge: 1600SC, 1650, 1750, 1950, 6800, 6850; SuSE SLES [32−Bit] 9: SP3 PCI−X QLogic QLA2340−E−SP4, 34, 35 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.252, SP3+ AX100
IBM xSeries: x336 (8837)26, x346 (8840)26; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
LangChao: NC2000, NC3000, NC3500, NF420, NF500, v2.6.5−7.276, SP3+
NF520; v2.6.5−7.282
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230

11/02/2006 166 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
284 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, 6650; SuSE SLES [32−Bit] 9: SP3 PCI−X QLogic: QLA200−E−SP4, 34, 41, FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ QLA210−E−SP4, 34, 41, FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)45, DL360(G4)45, v2.6.5−7.252, SP3+ QLA2340−E−SP34, 35 AX100
DL56045, DL74045, DL760 (G2)45, DL76045, ML570(G2)45 v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
285 Dell PowerEdge 1955 SuSE SLES [32−Bit] 9: SP3 PCI, PCI Dell: LPe1105−M4, 10, 13, 28 , FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, QME24624, 34, 59 FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
286 Fujitsu Siemens Primergy TX200 S3; SuSE SLES [32−Bit] 9: SP3 PCI, PCI Emulex LPe1150−E4, 10, 13, 28 FC−AL, EMC Y
HPQ Proliant: DL380(G5), DL580(G4) v2.6.5−7.2446, 19, 20, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
287 HPQ Proliant: DL380(G5), DL580(G4) SuSE SLES [32−Bit] 9: SP3 PCI, PCI Emulex: LP101−E4, 9, 10, 13 , FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, LP1050−E10, 13, 29, LP982−E10, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X LPe111−E4, 10, 13, 18 ; AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+ HPQ: A8002A/FC2142SR
v2.6.5−7.276, SP3+ (LPe1150)4, 10, 13, 57 ,
v2.6.5−7.282 AD167A/FC2143 (LP1150)4, 10, 13,
60, AE311A/FC1142SR (QLE2460)4,
32, 94, AE312A/FC1242SR
(QLE2462)4, 32, 34;
QLogic: QLA200−E−SP4, 34, 41,
QLA210−E−SP4, 34, 41,
QLA2340−E−SP34, 35,
QLE220−E−SP4, 16, 17, 56 ,
QLE2460−E−SP4, 32, 34,
QLE2462−E−SP4, 32, 34
288 HPQ Proliant DL380(G5) SuSE SLES [32−Bit] 9: SP3 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Express, 34, 44, AE369A/FC1243 (QLA2462)4, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 34, 44 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
289 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850; SuSE SLES [32−Bit] 9: SP3 PCI, Emulex LP101−E4, 9, 10, 13 FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ PCI−X FC−SW CLARiiON
HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, v2.6.5−7.252, SP3+ AX100
DL380(G4)45, DL38045, DL38545, DL580(G2)45, v2.6.5−7.257, SP3+
DL580(G3)45, DL58545, ML370(G3)45, ML370(G4)45; v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
Samsung: ES470, ES570, SS140 v2.6.5−7.282
290 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, 2850; SuSE SLES [32−Bit] 9: SP3 PCI, Emulex: LP1050−E4, 10, 13, 29 , FC−AL, EMC Y
v2.6.5−7.2446, 19, 20, SP3+ PCI−X LP982−E4, 10, 13; FC−SW CLARiiON
Samsung: ES470, ES570, SS140 v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+ QLogic QLA2340−E−SP4, 34, 35
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
291 HPQ Proliant: DL14545, DL380(G2)45, DL380(G3)45, SuSE SLES [32−Bit] 9: SP3 PCI, Emulex: LP1050−E10, 13, 29, FC−AL, EMC Y
DL380(G4)45, DL38045, DL38545, DL580(G2)45, v2.6.5−7.2446, 19, 20, SP3+ PCI−X LP982−E10; FC−SW CLARiiON
DL580(G3)45, DL58545, ML370(G3)45, ML370(G4)45 v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+ HPQ AD167A/FC2143 (LP1150)4,
v2.6.5−7.267, SP3+ 10, 13, 60 ;
v2.6.5−7.276, SP3+ QLogic: QLA200−E−SP4, 34, 41,
v2.6.5−7.282 QLA210−E−SP4, 34, 41,
QLE220−E−SP4, 16, 17, 56
292 HPQ Proliant: DL380(G4)45, DL38545, DL58545, SuSE SLES [32−Bit] 9: SP3 PCI, HPQ: AB429A/FC1143 (QLA2460)4, FC−AL, EMC Y
ML370(G4)45 v2.6.5−7.2446, 19, 20, SP3+ PCI−X 34, 44, AE369A/FC1243 (QLA2462)4, FC−SW CLARiiON
v2.6.5−7.252, SP3+ 34, 44 AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
293 HPQ Proliant: DL14545, DL380(G4)45, DL38545, SuSE SLES [32−Bit] 9: SP3 PCI, QLogic QLA2340−E−SP34, 35 FC−AL, EMC Y
DL580(G2)45, DL580(G3)45, DL58545, ML370(G3)45, v2.6.5−7.2446, 19, 20, SP3+ PCI−X FC−SW CLARiiON
ML370(G4)45 v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
294 Bull NovaScale 2320 SuSE SLES [32−Bit] 106, 19, PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
20, 24, 25 Dual port: for NovaScale Blade CLARiiON
Series CFSN202−110052, 54, mini AX100
for NovaScale Blade 2021
CFSN202−210052, 54;
Bull SBEFCM (SFF) Mezzanine:
HBA4, 52, 54, HBA4, 52, 83, 84 ;
Bull SBEFCM4 (SFF) 4Gb
Mezzanine HBA51, 52
295 Digital Henge PowerBlade BS200L SuSE SLES [32−Bit] 106, 19, PCI−X Digital Henge Digital Henge: FC−SW EMC Y
20, 24, 25 SBEFCM44, 51, 52, SBEFCM52, 54, CLARiiON
SBFCM52, 54; AX100
Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD4, 52, 54

11/02/2006 167 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
296 IBM BladeCenter HS20 (Model: 7981), 8843); SuSE SLES [32−Bit] 106, 19, PCI−X IBM Emulex 4Gb SFF Fibre Channel FC−SW EMC Y
20, 24, 25 Exp Card (39Y9186)4, 27, 81, 82 CLARiiON
IBM BladeCenter LS20 (Model 8850) AX100
297 IBM BladeCenter: HS20 (Model 8843), LS20 (Model 8850) SuSE SLES [32−Bit] 106, 19, PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
20, 24, 25 (26R0890)4, 75, 85 CLARiiON
AX100
298 IBM BladeCenter HS20 (Model: 7981), 8832)55, SuSE SLES [32−Bit] 106, 19, PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8832−N1X), 8843); 20, 24, 25 Card4, 10, 27, 53 , HS20 4GB CLARiiON
Standard FC Exp Card (26R0884)4, AX100
IBM BladeCenter: HS40 (Model 8839), LS20 (Model 8850) 52, 69

299 IBM BladeCenter HS20 (Model 8843) SuSE SLES [32−Bit] 9 SP1+ PCI−X IBM HS20 FC Exp Card (26K4841)4, FC−SW EMC Y2, 3
v2.6.5−7.1516, 7 5, 35 CLARiiON
AX100
300 IBM BladeCenter LS20 (Model 8850) SuSE SLES [32−Bit] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y2, 3
v2.6.5−7.1516, 7 Card4, 10, 11, 53 , HS20 FC Exp Card CLARiiON
(13N2203) for IBM eServer LS204, 5, AX100
35, HS20 FC SFF Exp Card
(26K4841) for IBM eServer LS204, 5,
35

301 IBM BladeCenter HS20 (Model: 8678)55, 8832)55, SuSE SLES [32−Bit] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y2, 3
8832−N1X), 8843); v2.6.5−7.1516, 7 Card4, 10, 53, 80 , HS20 FC Exp Card CLARiiON
(13N2203)4, 5, 35, HS20 FC Exp AX100
IBM BladeCenter HS40 (Model 8839) Card (48P7061)4, 5, 35
302 IBM BladeCenter HS20 (Model: 7981), 8678)55, 8832)55, SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y2, 31
8832−N1X), 8843); v2.6.5−7.201, v2.6.5−7.202.7 (13N2203)4, 33, 35, (48P7061)4, 33, CLARiiON
35 AX100
IBM BladeCenter HS40 (Model 8839)
303 IBM BladeCenter LS20 (Model 8850) SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 (26R0890)4, 33, 85, FC Exp Card CLARiiON
(13N2203) for IBM eServer LS204, AX100
33, 35, FC SFF Exp Card (26K4841)
for IBM eServer LS204, 33, 35
304 IBM BladeCenter HS20 (Model 8843) SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y2, 31
v2.6.5−7.201, v2.6.5−7.202.7 (26R0890)4, 73, 85, FC Exp Card CLARiiON
(26K4841)4, 33, 35 AX100
305 IBM BladeCenter HS20 (Model: 7981), 8678)55, 8832)55, SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y2, 31
8832−N1X), 8843); v2.6.5−7.201, v2.6.5−7.202.7 Card4, 10, 53, 62 , HS20 4GB CLARiiON
Standard FC Exp Card (26R0884)4, AX100
IBM BladeCenter: HS40 (Model 8839), LS20 (Model 8850) 33, 69

306 Fujitsu Siemens Primergy: RX300 S2, TX300 S2 SuSE SLES [32−Bit] 9 SP2+: PCI−X QLogic QLA2340−E−SP35 FC−SW EMC Y
v2.6.5−7.201, v2.6.5−7.202.7; CLARiiON
AX100
SuSE SLES [32−Bit] 9: SP3
v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
307 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLA2340−E−SP35 FC−SW EMC Y
v2.6.5−7.244, SP3+ Express CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
308 Fujitsu Siemens Primergy: RX200 S3, RX220, RX600 S3, SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLA2340−E−SP35 FC−SW EMC Y
TX300 S3, TX600 S3 v2.6.5−7.244, SP3+ Express, CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
309 Bull NovaScale 2320; SuSE SLES [32−Bit] 9: SP3 PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
Digital Henge PowerBlade BS200L v2.6.5−7.244, SP3+ Dual port: for NovaScale Blade CLARiiON
v2.6.5−7.252, SP3+ Series CFSN202−110034, 54, mini AX100
v2.6.5−7.257, SP3+ for NovaScale Blade 2021
v2.6.5−7.267, SP3+ CFSN202−210034, 54
v2.6.5−7.276, SP3+
v2.6.5−7.282
310 Bull NovaScale 2320 SuSE SLES [32−Bit] 9: SP3 PCI−X Bull 2Gbps FC Mezzanine Card − FC−SW EMC Y
v2.6.5−7.244, SP3+ Dual port: for NovaScale Blade CLARiiON
v2.6.5−7.252, SP3+ Series CFSN202−110084, mini for AX100
v2.6.5−7.257, SP3+ NovaScale Blade 2021
v2.6.5−7.267, SP3+ CFSN202−210054;
v2.6.5−7.276, SP3+
v2.6.5−7.282 Bull SBEFCM (SFF) Mezzanine:
HBA34, 54, HBA84;
Bull SBEFCM4 (SFF) 4Gb
Mezzanine HBA34, 51
311 Digital Henge PowerBlade BS200L SuSE SLES [32−Bit] 9: SP3 PCI−X Bull SBEFCM (SFF) Mezzanine FC−SW EMC Y
v2.6.5−7.244, SP3+ HBA4, 34, 54; CLARiiON
v2.6.5−7.252, SP3+ Digital Henge Digital Henge: AX100
v2.6.5−7.257, SP3+ SBEFCM44, 34, 51, SBEFCM34, 54,
v2.6.5−7.267, SP3+ SBFCM34, 54;
v2.6.5−7.276, SP3+
v2.6.5−7.282 Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD4, 34, 54
312 Fujitsu Siemens Primergy TX200 S3 SuSE SLES [32−Bit] 9: SP3 PCI, PCI QLogic QLA2340−E−SP35 FC−SW EMC Y
v2.6.5−7.244, SP3+ Express, CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 168 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
313 IBM BladeCenter HS20 (Model: 7981), 8843); SuSE SLES [32−Bit] 9: SP3 PCI−X IBM Emulex 4Gb SFF Fibre Channel FC−SW EMC Y
v2.6.5−7.2446, 19, 20, SP3+ Exp Card (39Y9186)4, 13, 81, 82 CLARiiON
IBM BladeCenter: HS21 (Model 8853)91, LS20 (Model v2.6.5−7.252, SP3+ AX100
8850), LS21 (Model 7971), LS41 (Model 7972) v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
314 IBM BladeCenter: HS20 (Model 8843), HS21 (Model SuSE SLES [32−Bit] 9: SP3 PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)91, LS20 (Model 8850), LS21 (Model 7971), LS41 v2.6.5−7.2446, 19, 20, SP3+ (26R0890)4, 34, 85 CLARiiON
(Model 7972) v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
315 IBM BladeCenter HS20 (Model 8843) SuSE SLES [32−Bit] 9: SP3 PCI−X IBM HS20 FC Exp Card (26K4841)4, FC−SW EMC Y
v2.6.5−7.2446, 19, 20, SP3+ 34, 35 CLARiiON
v2.6.5−7.252, SP3+ AX100
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
316 IBM BladeCenter HS20 (Model: 7981), 8678)55, 8832)55, SuSE SLES [32−Bit] 9: SP3 PCI−X IBM HS20 FC Exp Card: FC−SW EMC Y
8832−N1X), 8843); v2.6.5−7.2446, 19, 20, SP3+ (13N2203)4, 34, 35, (48P7061)4, 34, CLARiiON
v2.6.5−7.252, SP3+ 35 AX100
IBM BladeCenter: HS21 (Model 8853)91, HS40 (Model v2.6.5−7.257, SP3+
8839) v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
317 IBM BladeCenter LS20 (Model 8850) SuSE SLES [32−Bit] 9: SP3 PCI−X IBM HS20 FC: Exp Card (13N2203) FC−SW EMC Y
v2.6.5−7.2446, 19, 20, SP3+ for IBM eServer LS204, 34, 35, SFF CLARiiON
v2.6.5−7.252, SP3+ Exp Card (26K4841) for IBM AX100
v2.6.5−7.257, SP3+ eServer LS204, 34, 35
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
318 IBM BladeCenter HS20 (Model: 7981), 8678)55, 8832)55, SuSE SLES [32−Bit] 9: SP3 PCI−X IBM: Emulex LP1005DC FC Exp FC−SW EMC Y
8832−N1X), 8843); v2.6.5−7.2446, 19, 20, SP3+ Card4, 10, 13, 53 , HS20 4GB CLARiiON
v2.6.5−7.252, SP3+ Standard FC Exp Card (26R0884)4, AX100
IBM BladeCenter: HS40 (Model 8839), LS20 (Model 8850) v2.6.5−7.257, SP3+ 34, 69
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
1. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. VxVM is not supported on servers booting from the array.
3. Booting from the SAN with PowerPath is not supported.
4. SNIA HBA API Supported.
5. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. SGI's XFS filesystem is supported.
7. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
8. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
12. Firmware Version 1.91a1
13. Driver Version 8.0.16.17 Driver is integrated into the kernel.
14. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
15. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
16. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
17. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
18. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
19. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
20. Novell OES is supported on this kernel.
21. Firmware Version 2.50a8
22. BIOS 6.00a1
23. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
24. Native multipathing is not supported on boot−from−SAN configurations.
25. Supported kernels: 2.6.16.21−0.8.
Confirm kernel support with server vendor.
26. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
27. Driver Version 8.1.6 Driver is integrated into the kernel.
28. Firmware Version 2.50a6
29. Firmware Version 1.91a5
30. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
31. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
32. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
34. Driver Version 8.01.02−sles Driver is integrated into the kernel.
35. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. PowerPath is not supported.
37. This HBA is equivalent to the QLogic QLA2340.
38. Firmware Version 2.10a10
39. This LVM has been modified by SuSE so that it provides support for both native sd device file names as well as for PowerPath emcpower pseudo device file names.
40. Driver Version 7.1.14
41. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
42. Driver Version 7.03.00 Driver is integrated into the kernel.
43. Driver Version 7.03.00
44. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
45. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
46. BIOS 1.16
47. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
48. Driver Version 7.03.00 Driver/BIOS are available at http://www.qlogic.com
49. Driver Version 6.05.00
50. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
51. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
52. Driver Version 8.01.04−k Driver is integrated into the kernel.
53. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

11/02/2006 169 CLARiiON AX100


CLARiiON AX100

54. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com


55. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
56. Driver/BIOS are available at http://www.qlogic.com
57. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
58. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
59. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
60. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
61. Firmware Version 3.92a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
62. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
63. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
64. Accepts PCI−X 1.0 and 2.0 HBAs.
65. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
66. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
67. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
68. Driver Version 8.0.16.17
69. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
70. Driver Version 8.01.00 Driver is integrated into the kernel.
71. The Emulex LP9XXX HBA family requires a host PCI bus capable of supplying 3.3 VDC bus power. The PCI slot can use either 3.3 VDC or 5.0 VDC signaling interfaces.
72. Boot BIOS 1.70a3 supported for external boot. Available at http://www.emulex.com
73. Driver Version 8.01.00
74. Driver Version 6.05.00 Driver is integrated into the kernel.
75. Driver Version 8.01.04−k
76. Driver Version 8.1.6
77. Driver Version 7.03.00 QLogic driver obtained from http://www.qlogic.com
78. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
79. Driver Version 8.0.16.6_p3
80. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
81. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
82. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
83. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
84. BIOS 1.43
85. BIOS 1.12
86. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
87. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
88. HP Netserver LH3000 U3 is supported in the same configurations as the standard LH 3000.
89. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
90. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
91. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
92. Firmware Version 1.91a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
93. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
94. Driver Version 8.01.02−sles Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
95. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

SuSE SLES [AMD−64]

SuSE SLES [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 HPQ Proliant: SuSE SLES [AMD−64] 9 SP1+ PCI, Emulex: LP101−E3, 6, 13, 30 , LP1050−E6, 16, 46, LP982−E6, 46; FC−AL, EMC N10, 28
DL14534, DL38534, v2.6.5−7.15125, 26, 27 PCI−X FC−SW CLARiiON
DL58534 QLogic: QLA200−E−SP3, 24, 37, QLA2340−E−SP18, 24 AX100
2 IBM eServer 326m SuSE SLES [AMD−64] 9 SP2+: PCI Emulex LP1050Ex−E3, 6, 13, 15 FC−AL, EMC Y
(Model 7969) v2.6.5−7.201, v2.6.5−7.20125, 26, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
3 IBM eServer 326m SuSE SLES [AMD−64] 9 SP2+: PCI Emulex: LPe111−E3, 6, 17, 47 , LPe1150−E3, 6, 7, 8; FC−AL, EMC Y10, 28
(Model 7969) v2.6.5−7.201, v2.6.5−7.20125, 26, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X QLogic: QLE2360−E−SP3, 11, 12, 35 , QLE2460−E−SP2, 3, 11 AX100
4 HPQ Proliant: SuSE SLES [AMD−64] 9 SP2+: PCI, Emulex: LP101−E3, 6, 13, 42 , LP1050−E6, 16, 42, LP982−E6, 42 FC−AL, EMC Y10
DL14534, DL38534, v2.6.5−7.201, v2.6.5−7.20125, 26, PCI−X FC−SW CLARiiON
DL58534 v2.6.5−7.202.7 AX100
5 HPQ Proliant: SuSE SLES [AMD−64] 9 SP2+: PCI, HPQ AD167A/FC2143 (LP1150)3, 6, 15, 33 ; FC−AL, EMC Y9, 10
DL14534, DL38534, v2.6.5−7.201, v2.6.5−7.20125, 26, PCI−X QLogic: QLA200−E−SP3, 37, 41, QLA210−E−SP3, 11, 37, FC−SW CLARiiON
DL58534 v2.6.5−7.202.7 QLA2340−E−SP18, 41 AX100
6 Dell PowerEdge 6950 SuSE SLES [AMD−64] 9 SP2+: PCI Emulex: LP101−E3, 6, 13, 15 , LP1050−E3, 6, 15, 16 , FC−AL, EMC Y9, 10
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050Ex−E3, 6, 13, 15 , LP982−E3, 6, 15, LPe111−E3, 6, 17, 47 , FC−SW CLARiiON
PCI−X LPe1150−E3, 6, 7, 8; AX100
QLogic: QLA2340−E−SP3, 11, 18, QLE2360−E−SP3, 11, 12, 35 ,
QLE2460−E−SP2, 3, 11
7 IBM xSeries x3455 SuSE SLES [AMD−64] 9: SP3 PCI Emulex LP1050Ex−E3, 6, 13, 14 ; FC−AL, EMC Y, Y1
(7984) v2.6.5−7.244, SP3+ v2.6.5−7.252, Express IBM: 42C2069 (LPe11000)3, 6, 14, 43 , 42C2071 (LPe11002)3, 6, FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ 14, 43; AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282 QLogic: QLE2360−E−SP3, 4, 12, QLE2460−E−SP2, 3, 4
8 HPQ Proliant BL465c: SuSE SLES [AMD−64] 9: SP3 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y21, Y9,
(403433−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, Express Bladesystem (403621−B21)14, 19, 20 FC−SW CLARiiON 10
(403434−B21), SP3+ v2.6.5−7.257, SP3+ AX100
(407234−B21), v2.6.5−7.267, SP3+ v2.6.5−7.276,
(407235−B21) SP3+ v2.6.5−7.282
9 HPQ Proliant BL465c: SuSE SLES [AMD−64] 9: SP3 PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(403433−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, Express Bladesystem (403619−B21)4, 5 FC−SW CLARiiON
(403434−B21), SP3+ v2.6.5−7.257, SP3+ AX100
(407234−B21), v2.6.5−7.267, SP3+ v2.6.5−7.276,
(407235−B21) SP3+ v2.6.5−7.282
10 HPQ Proliant BL465c: SuSE SLES [AMD−64] 9: SP3 PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y
(403433−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, Express Bladesystem (403621−B21)14, 19, 20, QLogic QMH2462 4Gb FC−SW CLARiiON
(403434−B21), SP3+ v2.6.5−7.257, SP3+ FC HBA for HP c−Class Bladesystem (403619−B21)4, 5 AX100
(407234−B21), v2.6.5−7.267, SP3+ v2.6.5−7.276,
(407235−B21) SP3+ v2.6.5−7.282

11/02/2006 170 CLARiiON AX100


CLARiiON AX100

SuSE SLES [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
11 Dell PowerEdge 6950; SuSE SLES [AMD−64] 9: SP3 PCI Emulex: LP101−E3, 6, 13, 14 , LP1050−E3, 6, 14, 16 , FC−AL, EMC Y
IBM xSeries x3755 v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, LP1050Ex−E3, 6, 13, 14 , LP982−E3, 6, 14; FC−SW CLARiiON
(8877) SP3+ v2.6.5−7.257, SP3+ PCI−X AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276, QLogic: QLA2340−E−SP3, 4, 18, QLE2460−E−SP2, 3, 4
SP3+ v2.6.5−7.282
12 IBM xSeries x3755 SuSE SLES [AMD−64] 9: SP3 PCI Emulex: LP1050−E3, 6, 14, 16 , LP1050Ex−E3, 6, 13, 14 , FC−AL, EMC Y1
(8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, LP1150−E3, 6, 14, 44 , LP982−E3, 6, 14, LPe111−E3, 6, 14, 17 , FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ PCI−X LPe1150−E3, 6, 8, 14; AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282 IBM: 24P0960 (QLA2340)3, 4, 18, 23 , 24P8053 (QLA2342)3, 4,
18,39M5894 (QLA2460)2, 3, 4, 39M5895 (QLA2462)2, 3, 4;
QLogic: QLA2340−E−SP3, 4, 18, QLA2460−E−SP2, 3, 4,
QLE2360−E−SP3, 4, 12, QLE2460−E−SP2, 3, 4
13 Dell PowerEdge 6950 SuSE SLES [AMD−64] 9: SP3 PCI Emulex: LPe111−E3, 6, 14, 17 , LPe1150−E3, 6, 8, 14; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ PCI−X QLogic: QLE220−E−SP3, 39, 40, QLE2360−E−SP3, 4, 12, 35 AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
14 IBM xSeries x3755 SuSE SLES [AMD−64] 9: SP3 PCI IBM: 24P0960 (QLA2340)3, 18, 22, 23 , 24P8053 (QLA2342)3, FC−AL, EMC Y
(8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, 18, 22, 39M5894 (QLA2460)2, 3, 4, 39M5895 (QLA2462)2, 3, 4; FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ PCI−X AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276, QLogic: QLA2460−E−SP2, 3, 4, QLE2360−E−SP3, 4, 12
SP3+ v2.6.5−7.282
15 HPQ Proliant: SuSE SLES [AMD−64] 9: SP3 PCI, Emulex: LP101−E3, 6, 13, 14 , LP1050−E6, 14, 16, LP982−E6, 14; FC−AL, EMC Y
DL14534, DL38534, v2.6.5−7.244, SP3+ v2.6.5−7.252, PCI−X FC−SW CLARiiON
DL58534 SP3+ v2.6.5−7.257, SP3+ HPQ AD167A/FC2143 (LP1150)3, 6, 14, 33 ; AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276, QLogic: QLA200−E−SP3, 4, 37, QLA210−E−SP3, 4, 37,
SP3+ v2.6.5−7.282 QLA2340−E−SP4, 18, QLE220−E−SP3, 39, 40, 45
16 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp Card3, 6, 29, 30 , HS20 FC Exp FC−SW EMC Y10, 28
(Model 8850) v2.6.5−7.15125, 26, 27 Card (13N2203) for IBM eServer LS203, 18, 24, HS20 FC SFF CLARiiON
Exp Card (26K4841) for IBM eServer LS203, 18, 24 AX100
17 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9 SP2+: PCI−X IBM HS20 4GB: SFF FC Exp Card (26R0890)3, 11, 38, FC−SW EMC Y9, 10
(Model 8850) v2.6.5−7.201, v2.6.5−7.20125, 26, Standard FC Exp Card (26R0884)3, 11, 36 CLARiiON
v2.6.5−7.202.7 AX100
18 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp Card3, 6, 15, 29 , HS20 FC Exp FC−SW EMC Y10
(Model 8850) v2.6.5−7.201, v2.6.5−7.20125, 26, Card (13N2203) for IBM eServer LS203, 11, 18, HS20 FC SFF CLARiiON
v2.6.5−7.202.7 Exp Card (26K4841) for IBM eServer LS203, 11, 18 AX100
19 IBM BladeCenter: LS20 SuSE SLES [AMD−64] 9: SP3 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)3, FC−SW EMC Y
(Model 8850), LS21 v2.6.5−7.244, SP3+ v2.6.5−7.252, 14, 31, 32 , HS20 4GB SFF FC Exp Card (26R0890)3, 4, 38 CLARiiON
(Model 7971), LS41 SP3+ v2.6.5−7.257, SP3+ AX100
(Model 7972) v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
20 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9: SP3 PCI−X IBM: Emulex LP1005DC FC Exp Card3, 6, 14, 29 , HS20 4GB FC−SW EMC Y
(Model 8850) v2.6.5−7.244, SP3+ v2.6.5−7.252, Standard FC Exp Card (26R0884)3, 4, 36, HS20 FC Exp Card CLARiiON
SP3+ v2.6.5−7.257, SP3+ (13N2203) for IBM eServer LS203, 4, 18, HS20 FC SFF Exp AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276, Card (26K4841) for IBM eServer LS203, 4, 18
SP3+ v2.6.5−7.282
1. PowerPath is not supported.
2. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. SNIA HBA API Supported.
4. Driver Version 8.01.02−sles Driver is integrated into the kernel.
5. BIOS 1.16
6. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
8. Firmware Version 2.50a6
9. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
10. VxVM is not supported on servers booting from the array.
11. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
14. Driver Version 8.0.16.17 Driver is integrated into the kernel.
15. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
16. Firmware Version 1.91a5
17. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
18. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Firmware Version 2.50a8
20. BIOS 6.00a1
21. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
22. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. This HBA is equivalent to the QLogic QLA2340.
24. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
26. SGI's XFS filesystem is supported.
27. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
28. Booting from the SAN with PowerPath is not supported.
29. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
31. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
33. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
34. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
35. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
36. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
38. BIOS 1.12
39. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
40. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
41. Driver Version 8.01.00
42. Driver Version 8.0.16.6_p3
43. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
44. Firmware Version 2.10a10
45. Driver/BIOS are available at http://www.qlogic.com
46.

11/02/2006 171 CLARiiON AX100


CLARiiON AX100

Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
47. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

SuSE SLES [EM64T]

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP1+ PCI Emulex LP1050Ex−E3, 4, 6, 47 FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.5−7.1517, 8, 42 Express FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)37;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
2 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP1+ PCI QLogic QLE2360−E−SP4, 30, 31, 44 FC−AL, EMC Y2, 43
2800, 2850, 6800, 6850; v2.6.5−7.1517, 8, 42 Express FC−SW CLARiiON
AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)37;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
3 HPQ Proliant ML350(G4)13 SuSE SLES [EM64T] 9 SP1+ PCI Emulex: LP101−E3, 4, 6, 47, LP1050−E3, 22, 48, FC−AL, EMC N2, 43
v2.6.5−7.1517, 8, 42 Express, LP982−E3, 48; FC−SW CLARiiON
PCI−X AX100
QLogic: QLA200−E−SP4, 21, 44, QLA2340−E−SP9, 44
4 Dell PowerEdge 1855 SuSE SLES [EM64T] 9 SP1+ PCI−X Dell 2342M9, 44 FC−AL, EMC N2, 43
v2.6.5−7.1517, 8, 42 FC−SW CLARiiON
AX100
5 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP1+ PCI−X Emulex LP101−E3, 4, 33, 47 ; FC−AL, EMC N2, 43
RX200 S2, RX300 S2, RX600 v2.6.5−7.1517, 8, 42 QLogic QLA2340−E−SP9 FC−SW CLARiiON
S2, TX200 S2, TX300 S2, AX100
TX600 S2
6 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP1+ PCI−X Emulex LP1050Ex−E3, 4, 33, 47 FC−AL, EMC Y
RX200 S2, RX600 S2, TX600 v2.6.5−7.1517, 8, 42 FC−SW CLARiiON
S2 AX100
7 HPQ Proliant DL360(G4)13 SuSE SLES [EM64T] 9 SP1+ PCI−X Emulex: LP101−E3, 4, 6, 47, LP1050−E3, 22, 48, FC−AL, EMC N2, 43
v2.6.5−7.1517, 8, 42 LP982−E3, 48 FC−SW CLARiiON
AX100
8 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP1+ PCI−X QLogic QLA2340−E−SP4, 9, 44 FC−AL, EMC N2, 43
RX200 S2, RX600 S2, TX600 v2.6.5−7.1517, 8, 42 FC−SW CLARiiON
S2 AX100
9 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP1+ PCI−X QLogic: QLA200−E−SP4, 21, 44, QLA2340−E−SP9, 44 FC−AL, EMC N2, 43
RX200 S2, RX300 S2, RX600 v2.6.5−7.1517, 8, 42 FC−SW CLARiiON
S2, TX200 S2, TX300 S2, AX100
TX600 S2;
HPQ Proliant DL360(G4)13
10 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9 SP1+ PCI, Emulex: LP101−E3, 4, 6, 47, LP1050−E3, 22, 48, FC−AL, EMC N2, 43
ML370(G4)13 v2.6.5−7.1517, 8, 42 PCI−X LP982−E3, 48; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP4, 21, 44, QLA2340−E−SP9, 44
11 Samsung ES470 SuSE SLES [EM64T] 9 SP1+ PCI, Emulex: LP101−E3, 4, 6, 47, LP1050−E3, 4, 22, 47 , FC−AL, EMC Y2, 43
v2.6.5−7.1517, 8, 42 PCI−X LP982−E3, 4, 47; FC−SW CLARiiON
AX100
QLogic QLA2340−E−SP4, 9, 44
12 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LP1050Ex−E3, 4, 5, 6; FC−AL, EMC Y1, 2
1950, 2800, 2850, 6800, v2.6.5−7.201, v2.6.5−7.2017, 8, Express QLogic QLE2360−E−SP4, 14, 30, 31 FC−SW CLARiiON
6850; v2.6.5−7.202.7 AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)37;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230

11/02/2006 172 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
13 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LPe111−E3, 4, 24, 35 FC−AL, EMC Y1, 2
1950, 2800, 2850, 6800, v2.6.5−7.201, v2.6.5−7.2017, 8, Express FC−SW CLARiiON
6850; v2.6.5−7.202.7 AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
14 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LPe1150−E3, 4, 18, 19 ; FC−AL, EMC Y1, 2
1950, 2800, 2850, 6800, v2.6.5−7.201, v2.6.5−7.2017, 8, Express QLogic QLE2460−E−SP4, 14, 16 FC−SW CLARiiON
6850; v2.6.5−7.202.7 AX100
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
15 HPQ Proliant: DL360(G4)13, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LPe1150−E3, 4, 19, 23 ; FC−AL, EMC Y1, 2
DL380(G4)13, DL580(G3)13, v2.6.5−7.201, v2.6.5−7.2017, 8, Express HPQ: A8002A/FC2142SR (LPe1150)3, 4, 5, 20, FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 v2.6.5−7.202.7 AD167A/FC2143 (LP1150)3, 4, 5, 36 AX100
16 Dell PowerEdge: 2900, 2950 SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP101−E3, 4, 5, 6, LP1050−E3, 4, 5, 22, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, Express, LP1050Ex−E3, 4, 5, 6, LP982−E3, 4, 5, LPe111−E3, 4, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X 24, 35, LPe1150−E3, 4, 18, 19 ; AX100
QLogic: QLA2340−E−SP4, 9, 14, QLE2360−E−SP4,
14, 30, 31 , QLE2460−E−SP4, 14, 16

17 HPQ Proliant ML350(G4)13 SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, Express, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
HPQ: AB429A/FC1143 (QLA2460)4, 14, 15,
AD167A/FC2143 (LP1150)3, 4, 5, 36,
AE369A/FC1243 (QLA2462)4, 14, 15;
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14

18 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP1050Ex−E3, 4, 5, 33, LPe1150−E3, 4, 19, 35 FC−AL, EMC Y
RX220 v2.6.5−7.201, v2.6.5−7.2017, 8, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
19 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP1050Ex−E3, 4, 5, LPe1150−E3, 4, 19, FC−AL, EMC Y1, 2
RX220 v2.6.5−7.201, v2.6.5−7.2017, 8, Express, LPe1150−E3, 4, 19, 23 FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
20 Dell PowerEdge 1855; SuSE SLES [EM64T] 9 SP2+: PCI−X Dell 2342M9, 14 FC−AL, EMC Y1, 2
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
v2.6.5−7.202.7 AX100
21 Dell PowerEdge 1855 SuSE SLES [EM64T] 9 SP2+: PCI−X Dell: LPe1105−M3, 4, 5, 19, QME24624, 14, 40 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
v2.6.5−7.202.7 AX100
22 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LP1050Ex−E3, 4, 5, 33 FC−AL, EMC Y
RX200 S2, RX600 S2, TX600 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
S2 v2.6.5−7.202.7 AX100
23 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LPe1150−E3, 4, 19, 35 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
v2.6.5−7.202.7 AX100
24 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 4, 5, 6, LP1050−E3, 4, 5, 22, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, LP982−E3, 4, 5; FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.202.7 AX100
37
IBM xSeries: x336 (8837) , QLogic QLA2340−E−SP4, 9, 14
x346 (8840)37, x3850/x366
(8863)38, 39;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
25 HPQ Proliant DL360(G4)13 SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 AX100
HPQ: AB429A/FC1143 (QLA2460)4, 14, 15,
AD167A/FC2143 (LP1150)3, 4, 5, 36,
AE369A/FC1243 (QLA2462)4, 14, 15;
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14

11/02/2006 173 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
26 IBM xSeries: x3800/x260 SuSE SLES [EM64T] 9 SP2+: PCI−X41 Emulex: LP101−E3, 4, 5, 6, LP1050−E3, 4, 5, 22, FC−AL, EMC Y1, 2
(8865)38, 39, v2.6.5−7.201, v2.6.5−7.2017, 8, LP982−E3, 4, 5; FC−SW CLARiiON
x3950/x3950E/x460 (8872, v2.6.5−7.202.7 AX100
8874)38, 39 QLogic QLA2340−E−SP4, 9, 14
27 Dell PowerEdge 1955 SuSE SLES [EM64T] 9 SP2+: PCI, PCI Dell: LPe1105−M3, 4, 5, 19, QME24624, 14, 40 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.2017, 8, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX100
28 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI, Emulex LP1050−E3, 4, 33, 35 ; FC−AL, EMC Y
RX800 S2 v2.6.5−7.201, v2.6.5−7.2017, 8, PCI−X QLogic: QLA2340−E−SP4, 9, 14, QLA2340−E−SP9, FC−SW CLARiiON
v2.6.5−7.202.7 14 AX100
29 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 4, 5, 6, LP1050−E3, 4, 5, 22, FC−AL, EMC Y1, 2
2600, 2650, 2800, 2850; v2.6.5−7.201, v2.6.5−7.2017, 8, PCI−X LP982−E3, 4, 5; FC−SW CLARiiON
v2.6.5−7.202.7 AX100
Samsung: ES470, ES570, QLogic QLA2340−E−SP4, 9, 14
SS140
30 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9 SP2+: PCI, HPQ: AB429A/FC1143 (QLA2460)4, 14, 15, FC−AL, EMC Y1, 2
ML370(G4)13 v2.6.5−7.201, v2.6.5−7.2017, 8, PCI−X AD167A/FC2143 (LP1150)3, 4, 5, 36, FC−SW CLARiiON
v2.6.5−7.202.7 AE369A/FC1243 (QLA2462)4, 14, 15 AX100
31 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X QLogic QLA2340−E−SP4, 9 FC−AL, EMC Y
RX200 S2, RX600 S2, TX600 v2.6.5−7.201, v2.6.5−7.2017, 8, FC−SW CLARiiON
S2 v2.6.5−7.202.7; AX100
SuSE SLES [EM64T] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
32 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex LP1050−E3, 4, 33, 35 ; FC−AL, EMC Y
BX620: S2F60, S260; v2.6.5−7.201, v2.6.5−7.202.7 Fujitsu Siemens BX600−FC22Q4, 9, 45, 50 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy
BX630: (2−way), (4−way)
33 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LP1050−E3, 4, 33, 35 FC−AL, EMC Y
RX200 S2, RX300 S2, TX200 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
S2, TX300 S2 AX100
34 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 4, 33, 35 , LP101−E3, 33, 35; FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
S2 Fujitsu Siemens S26361−F2843−E1 (Emulex: AX100
LP9802)3, 33, LP9802)3, 33, 51, 52 ;
QLogic: QLA200−E−SP4, 21, 46, QLA210−E−SP4, 14,
21

35 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
ML370(G4)13 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14

36 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X QLogic QLA2340−E−SP9 FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 v2.6.5−7.201, v2.6.5−7.202.7; FC−SW CLARiiON
S2 AX100
SuSE SLES [EM64T] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
37 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex LP1050−E3, 4, 33, 35 ; FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.5−7.2017, 8, v2.6.5−7.202.7 Fujitsu Siemens BX600−FC22Q4, 9, 45, 50 FC−SW CLARiiON
AX100
38 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex LP1050−E3, 4, 33, 35 FC−AL, EMC Y
RX200 S2 v2.6.5−7.2017, 8, v2.6.5−7.202.7 FC−SW CLARiiON
AX100
39 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 4, 6, 23, LP1050−E3, 22, 23, FC−AL, EMC Y1, 2
DL580(G3)13, ML370(G4)13 v2.6.5−7.2017, 8, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX100
QLogic: QLA200−E−SP4, 14, 21, QLA210−E−SP4, 14,
21, QLA2340−E−SP9, 14

40 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050−E3, 4, 11, 33 FC−AL, EMC Y
BX620: S2F60, S260; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
BX630: (2−way), (4−way)
41 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 9, 45 FC−AL, EMC Y
BX620: S2F60, S260, S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
BX630 (8−way)
42 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q4, 9, 10, 45 FC−AL, EMC Y
BX620 S3, BX630 (2−way), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
BX630 (4−way), BX630 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
(8−way) v2.6.5−7.276, SP3+ v2.6.5−7.282
43 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 33, 34 ; FC−AL, EMC Y
RX300 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express QLogic: QLA2340−E−SP4, 9, QLA2340−E−SP4, 9, 10, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ QLA2340−E−SP9, QLA2340−E−SP9, 10 AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
44 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 6, 11; FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express QLogic QLE2360−E−SP4, 10, 30, 31 FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)37;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230

11/02/2006 174 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
45 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe111−E3, 4, 11, 24 FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
46 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
Fujitsu Siemens Primergy
RX300 S3;
HPQ Proliant: DL360(G4)13,
DL380(G4)13, DL580(G3)13,
ML350(G4)13, ML370(G4)13;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
47 HPQ Proliant: DL360(G4)13, SuSE SLES [EM64T] 9: SP3 PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, 11, 20 , FC−AL, EMC Y
DL380(G4)13, DL580(G3)13, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express AD167A/FC2143 (LP1150)3, 4, 11, 36 FC−SW CLARiiON
ML350(G4)13, ML370(G4)13 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
48 Dell PowerEdge 1950 SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE220−E−SP4, 25, 26 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
49 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE2460−E−SP4, 10, 16 FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
50 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 11 FC−AL, EMC Y, Y17
RX220 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
51 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 33, 34 FC−AL, EMC Y
RX220, RX600 S3, TX300 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX600 S3 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
52 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe111−E3, 4, 11, 24 ; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, QLogic QLE2360−E−SP4, 10, 30, 31 FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
53 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Fujitsu Siemens Primergy:
RX200 S3, RX220, RX600
S3, TX300 S3, TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
54 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y17
RX220; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
x3650 (7979), x3755 (8877) v2.6.5−7.276, SP3+ v2.6.5−7.282

11/02/2006 175 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
55 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 4, 11, 22 , FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, LP1050Ex−E3, 4, 6, 11, LP982−E3, 4, 11; FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282 QLogic QLE2460−E−SP4, 10, 16
IBM xSeries: x3550 (7978),
x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
56 HPQ Proliant ML350(G4)13 SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP101−E3, 4, 6, LP1050−E3, 22, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 10, 15, AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 AD167A/FC2143 (LP1150)3, 4, 11, 36 ,
AE369A/FC1243 (QLA2462)4, 10, 15;
QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLE220−E−SP4, 25, 26, 27

57 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP1050Ex−E3, 4, 6, 11, LP1150−E3, 4, 11, 32 , FC−AL, EMC Y17
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, LPe111−E3, 4, 11, 24 ; FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 IBM: 24P0960 (QLA2340)4, 9, 10, 29 , 24P8053
(QLA2342)4, 9, 10, 39M5894 (QLA2460)4, 10, 16,
39M5895 (QLA2462)4, 10, 16;
QLogic: QLA2460−E−SP4, 10, 16, QLE2360−E−SP4,
10, 30, QLE2460−E−SP4, 10, 16

58 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI IBM: 24P0960 (QLA2340)4, 9, 28, 29 , 24P8053 FC−AL, EMC Y
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, (QLA2342)4, 9, 28, 39M5894 (QLA2460)4, 10, 16, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X 39M5895 (QLA2462)4, 10, 16; AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
QLogic: QLA2460−E−SP4, 10, 16, QLE2360−E−SP4,
10, 30

59 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP4, 9, 10 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Fujitsu Siemens Primergy:
RX200 S3, RX220, RX600
S3, TX300 S3, TX600 S3;
IBM xSeries: x3550 (7978),
x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
60 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX300 S3, TX600 S3; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
HPQ Proliant ML350(G4)13
61 Dell PowerEdge: 1850, 1900, SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE220−E−SP4, 25, 26 FC−AL, EMC Y
2850, 2900, 2950, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
62 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic: QLA2340−E−SP4, 9, QLA2340−E−SP9 FC−AL, EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX300 S3, TX600 S3 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
63 Dell PowerEdge 1855; SuSE SLES [EM64T] 9: SP3 PCI−X Dell 2342M9, 10 FC−AL, EMC Y
Unisys ES3105 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
64 Dell PowerEdge 1855 SuSE SLES [EM64T] 9: SP3 PCI−X Dell: LPe1105−M3, 4, 11, 19 , QME24624, 10, 40 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
65 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP1050−E3, 4, 11, 33 FC−AL, EMC Y
RX200 S2, RX300 S2, TX200 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
S2, TX300 S2 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
66 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP1050Ex−E3, 4, 33, 34 FC−AL, EMC Y
RX200 S2, RX600 S2, TX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
S2 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
67 IBM xSeries x3850/x366 SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP9802−E3, 4, 6, 11 FC−AL, EMC Y
(8863)38, 39 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
68 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y
RX600 S2, TX600 S2 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
69 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 4, 33, LP101−E3, 33; FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
S2 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ Fujitsu Siemens S26361−F2843−E1 (Emulex: AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 LP9802)3, 33, 34, LP9802)3, 33, 34, 51, 52

11/02/2006 176 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
70 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 4, 11, 22 , FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ LP982−E3, 4, 11 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
IBM xSeries: x336 (8837)37, v2.6.5−7.276, SP3+ v2.6.5−7.282
x346 (8840)37, x3850/x366
(8863)38, 39;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
71 HPQ Proliant DL360(G4)13 SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 4, 6, LP1050−E3, 22, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ HPQ: AB429A/FC1143 (QLA2460)4, 10, 15, AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 AD167A/FC2143 (LP1150)3, 4, 11, 36 ,
AE369A/FC1243 (QLA2462)4, 10, 15;
QLogic QLA2340−E−SP9, 10
72 HPQ Proliant BL460c: SuSE SLES [EM64T] 9: SP3 PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y1, 2
(416653−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ c−Class Bladesystem (403621−B21)11, 24, 58 FC−SW CLARiiON
(416654−B21), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
(416655−B21), v2.6.5−7.276, SP3+ v2.6.5−7.282
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21), (416669−B21)
73 HPQ Proliant BL460c: SuSE SLES [EM64T] 9: SP3 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(416653−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Bladesystem (403619−B21)28, 57 FC−SW CLARiiON
(416654−B21), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
(416655−B21), v2.6.5−7.276, SP3+ v2.6.5−7.282
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21), (416669−B21)
74 Dell PowerEdge: 1950, 6800, SuSE SLES [EM64T] 9: SP3 PCI−X QLogic QLA2340−E−SP4, 9, 10 FC−AL, EMC Y
6850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Digital Henge SH4500R4; v2.6.5−7.276, SP3+ v2.6.5−7.282
IBM xSeries: x336 (8837)37,
x346 (8840)37, x3850/x366
(8863)38, 39;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
75 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI−X QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10, FC−AL, EMC Y
RX300 S2, TX200 S2, TX300 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ 21, QLE220−E−SP4, 25, 26, 27 FC−SW CLARiiON
S2; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
HPQ Proliant DL360(G4)13
76 Dell PowerEdge 1955 SuSE SLES [EM64T] 9: SP3 PCI, PCI Dell: LPe1105−M3, 4, 11, 19 , QME24624, 10, 40 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
77 HPQ Proliant: DL380(G5), SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex LPe111−E3, 4, 11, 24 ; FC−AL, EMC Y
DL580(G4) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, HPQ: A8002A/FC2142SR (LPe1150)3, 4, 11, 20 , FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AD167A/FC2143 (LP1150)3, 4, 11, 36 , AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE311A/FC1142SR (QLE2460)4, 16, 56,
AE312A/FC1242SR (QLE2462)4, 10, 16;
QLogic: QLE2460−E−SP4, 10, 16, QLE2462−E−SP4,
10, 16

78 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex LPe1150−E3, 4, 11, 19 FC−AL, EMC Y
TX200 S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
DL580(G4) v2.6.5−7.276, SP3+ v2.6.5−7.282
79 HPQ Proliant DL380(G5) SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LP101−E3, 4, 6, LP1050−E3, 22, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 10, 15, AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)4, 10, 15;
QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLE220−E−SP4, 25, 26, 27

11/02/2006 177 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
80 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
TX200 S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
HPQ Proliant DL380(G5) v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
81 Dell PowerEdge: 1800, 2800 SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLE220−E−SP4, 25, 26 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
82 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic: QLA2340−E−SP4, 9, QLA2340−E−SP4, 9, 10, FC−AL, EMC Y
TX200 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, QLA2340−E−SP9 FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
83 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, Emulex LP1050−E3, 4, 11, 33 FC−AL, EMC Y
RX800 S2 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
84 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 4, 11, 22 , FC−AL, EMC Y
2600, 2650, 2800, 2850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X LP982−E3, 4, 11 FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Samsung: ES470, ES570, v2.6.5−7.276, SP3+ v2.6.5−7.282
SS140
85 HPQ Proliant: DL380(G4)13, SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 4, 6, LP1050−E3, 22, LP982−E3; FC−AL, EMC Y
ML370(G4)13 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ HPQ: AB429A/FC1143 (QLA2460)4, 10, 15, AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282 AD167A/FC2143 (LP1150)3, 4, 11, 36 ,
AE369A/FC1243 (QLA2462)4, 10, 15;
QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLE220−E−SP4, 25, 26, 27

86 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI, QLogic QLA2340−E−SP4, 9, 10 FC−AL, EMC Y
2600, 2650, 2800, 2850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
RX800 S2;
Samsung: ES470, ES570,
SS140
87 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, QLogic QLA2340−E−SP9, 10 FC−AL, EMC Y
RX800 S2; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
HPQ Proliant: DL380(G4)13, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
ML370(G4)13 v2.6.5−7.276, SP3+ v2.6.5−7.282
88 HPQ Proliant DL580(G4) SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 11, 22, FC−AL, EMC Y
v2.6.5−7.2447, 8, SP3+ v2.6.5−7.252, Express, LP982−E3; FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, PCI−X AX100
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLA2340−E−SP9, 10, QLE220−E−SP4, 25, 26, 27

89 HPQ Proliant DL580(G3)13 SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 4, 6, 11, LP1050−E3, 11, 22, FC−AL, EMC Y
v2.6.5−7.2447, 8, SP3+ v2.6.5−7.252, PCI−X LP982−E3; FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, AX100
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLogic: QLA200−E−SP4, 10, 21, QLA210−E−SP4, 10,
21, QLA2340−E−SP9, 10, QLE220−E−SP4, 25, 26, 27

90 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP1+ PCI−X IBM HS20 FC Exp Card (26K4841)4, 9, 44 FC−SW EMC Y2, 43
(Model 8843) v2.6.5−7.1517, 8, 42 CLARiiON
AX100
91 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP1+ PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 12, 48 , FC−SW EMC Y2, 43
(Model: 8832−N1X), 8843) v2.6.5−7.1517, 8, 42 HS20 FC Exp Card (13N2203)4, 9, 44, HS20 FC Exp CLARiiON
Card (48P7061)4, 9, 44 AX100
92 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP1+ PCI−X QLogic QLA2340−E−SP9 FC−SW EMC N2, 43
RX200 S2, RX300 S2, RX600 v2.6.5−7.1517, 8, 42 CLARiiON
S2, TX300 S2, TX600 S2 AX100
93 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card (26R0890)4, 49, FC−SW EMC Y1, 2
(Model 8843) v2.6.5−7.201, v2.6.5−7.2017, 8, 50, FC Exp Card (26K4841)4, 9, 14 CLARiiON
v2.6.5−7.202.7 AX100
94 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 5, 12, FC−SW EMC Y1, 2
(Model: 8832−N1X), 8843) v2.6.5−7.201, v2.6.5−7.2017, 8, HS20 4GB Standard FC Exp Card (26R0884)4, 14, CLARiiON
v2.6.5−7.202.7 53, HS20 FC Exp Card (13N2203)4, 9, 14, HS20 FC AX100
Exp Card (48P7061)4, 9, 14
95 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9 SP2+: PCI−X QLogic QLA2340−E−SP9 FC−SW EMC Y
RX300 S2, TX300 S2 v2.6.5−7.201, v2.6.5−7.202.7; CLARiiON
AX100
SuSE SLES [EM64T] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
96 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP9 FC−SW EMC Y
RX300 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
97 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP9 FC−SW EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, CLARiiON
S3, TX300 S3, TX600 S3 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
98 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM HS20 FC Exp Card (26K4841)4, 9, 10 FC−SW EMC Y
(Model 8843) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
99 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM HS20 FC Exp Card: (13N2203)4, 9, 10, FC−SW EMC Y
(Model: 8832−N1X), 8843); v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ (48P7061)4, 9, 10 CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
IBM BladeCenter HS21 v2.6.5−7.276, SP3+ v2.6.5−7.282
(Model 8853)59

11/02/2006 178 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
100 IBM BladeCenter: HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843), HS21 (Model v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ (39Y9186)4, 11, 54, 55 , HS20 4GB SFF FC Exp Card CLARiiON
8853)59 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ (26R0890)4, 10, 49 AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
101 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 11, 12 , FC−SW EMC Y
(Model: 8832−N1X), 8843) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ HS20 4GB Standard FC Exp Card (26R0884)4, 10, 53 CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
102 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLA2340−E−SP9 FC−SW EMC Y
TX200 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX100
v2.6.5−7.276, SP3+ v2.6.5−7.282
1. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
2. VxVM is not supported on servers booting from the array.
3. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
4. SNIA HBA API Supported.
5. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
6. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
8. SGI's XFS filesystem is supported.
9. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Driver Version 8.01.02−sles Driver is integrated into the kernel.
11. Driver Version 8.0.16.17 Driver is integrated into the kernel.
12. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
13. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
14. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. PowerPath is not supported.
18. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
19. Firmware Version 2.50a6
20. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
21. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. Firmware Version 1.91a5
23. Driver Version 8.0.16.6_p3
24. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
25. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
26. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
27. Driver/BIOS are available at http://www.qlogic.com
28. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
29. This HBA is equivalent to the QLogic QLA2340.
30. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
31. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
32. Firmware Version 2.10a10
33. Firmware Version 1.91a1
34. Driver Version 8.0.16.17
35. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
36. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
37. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
38. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
39. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
40. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
41. Accepts PCI−X 1.0 and 2.0 HBAs.
42. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
43. Booting from the SAN with PowerPath is not supported.
44. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
45. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
46. Driver Version 8.01.00 Driver is integrated into the kernel.
47. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
48. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
49. BIOS 1.12
50. Driver Version 8.01.00
51. The Emulex LP9XXX HBA family requires a host PCI bus capable of supplying 3.3 VDC bus power. The PCI slot can use either 3.3 VDC or 5.0 VDC signaling interfaces.
52. Boot BIOS 1.70a3 supported for external boot. Available at http://www.emulex.com
53. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
54. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
55. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
56. Driver Version 8.01.02−sles Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
57. BIOS 1.16
58. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
59. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
60. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.

SuSE SLES [x86_64]

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Primergy: BX620 SuSE SLES PCI Emulex LP1050−E2, 3, 4, 14 FC−AL, EMC Y
S3, BX630 (2−way), BX630 (4−way) [x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100

11/02/2006 179 CLARiiON AX100


CLARiiON AX100

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
2 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI Emulex LP1050Ex−E1, 2, 3, 4; FC−AL, EMC Y
2800, 2850, 6800, 6850; [x86_64] 105, Express QLogic QLE2360−E−SP4, 17, 26, 27 FC−SW CLARiiON
6, 7, 8 AX100
IBM xSeries x336 (8837)15
3 Fujitsu Siemens Primergy RX300 S3 SuSE SLES PCI Emulex LP1050Ex−E2, 3, 4, 14; FC−AL, EMC Y
[x86_64] 105, Express QLogic: QLA2340−E−SP16, 17, QLA2340−E−SP4, 16, 17 FC−SW CLARiiON
6, 7, 8 AX100
4 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI Emulex LPe111−E2, 3, 4, 29 FC−AL, EMC Y
2800, 2850, 6800, 6850; [x86_64] 105, Express FC−SW CLARiiON
6, 7, 8 AX100
HPQ Proliant: DL360(G4)24,
DL380(G4)24, DL580(G3)24,
ML350(G4)24, ML370(G4)24
5 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI Emulex LPe1150−E2, 3, 4, 30 FC−AL, EMC Y
2800, 2850, 6800, 6850; [x86_64] 105, Express FC−SW CLARiiON
6, 7, 8 AX100
Fujitsu Siemens Primergy RX300
S3;
HPQ Proliant: DL360(G4)24,
DL380(G4)24, DL580(G3)24,
ML350(G4)24, ML370(G4)24
6 HPQ Proliant BL465c: SuSE SLES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y25, Y9,
(403433−B21), (403434−B21), [x86_64] 105, Express (403621−B21)11, 12, 13 FC−SW CLARiiON 10
(407234−B21), (407235−B21) 6, 7, 8 AX100
7 HPQ Proliant BL465c: SuSE SLES PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), (403434−B21), [x86_64] 105, Express (403619−B21)20, 21 FC−SW CLARiiON
(407234−B21), (407235−B21) 6, 7, 8 AX100
8 HPQ Proliant: DL360(G4)24, SuSE SLES PCI HPQ: A8002A/FC2142SR (LPe1150)2, 3, 4, 35, AD167A/FC2143 FC−AL, EMC Y
DL380(G4)24, DL580(G3)24, [x86_64] 105, Express (LP1150)2, 3, 4, 31 FC−SW CLARiiON
ML350(G4)24, ML370(G4)24 6, 7, 8 AX100
9 HPQ Proliant BL465c: SuSE SLES PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y
(403433−B21), (403434−B21), [x86_64] 105, Express (403621−B21)11, 12, 13, QLogic QMH2462 4Gb FC HBA for HP c−Class FC−SW CLARiiON
(407234−B21), (407235−B21) 6, 7, 8 Bladesystem (403619−B21)20, 21 AX100
10 Dell PowerEdge 1950 SuSE SLES PCI QLogic QLE220−E−SP4, 18, 19 FC−AL, EMC Y
[x86_64] 105, Express FC−SW CLARiiON
6, 7, 8 AX100
11 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI QLogic QLE2460−E−SP4, 17, 22 FC−AL, EMC Y
2800, 2850, 6800, 6850 [x86_64] 105, Express FC−SW CLARiiON
6, 7, 8 AX100
12 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI Emulex LP101−E1, 2, 3, 4 FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, 6, 7, 8 PCI−X AX100
AS1550, AS2500;
HPQ Proliant ML350(G4)24;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
13 Fujitsu Siemens Primergy TX300 S3 SuSE SLES PCI Emulex LP1050Ex−E2, 3, 4, 14 FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
14 Fujitsu Siemens Primergy: RX600 SuSE SLES PCI Emulex LP1050Ex−E2, 3, 4, 32 FC−AL, EMC Y
S3, TX600 S3 [x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
15 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI Emulex LPe1150−E2, 3, 4, 30; FC−AL, EMC Y
[x86_64] 105, Express, QLogic QLA2340−E−SP4, 16, 17 FC−SW CLARiiON
Digital Henge Revo: AS1500, 6, 7, 8 PCI−X AX100
AS1550, AS2500;
Fujitsu Siemens Primergy: RX200
S3, RX600 S3, TX300 S3, TX600
S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
16 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI Emulex: LP1050−E2, 3, 4, 33, LP1050Ex−E1, 2, 3, 4, LP982−E2, 3, 4, FC−AL, EMC Y
[x86_64] 105, Express, LPe111−E2, 3, 4, 29; FC−SW CLARiiON
Digital Henge Revo: AS1500, 6, 7, 8 PCI−X AX100
AS1550, AS2500; QLogic: QLE2360−E−SP4, 17, 26, 27 , QLE2460−E−SP4, 17, 22
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
17 HPQ Proliant ML350(G4)24 SuSE SLES PCI Emulex: LP1050−E2, 3, 33, LP982−E2, 3; FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 17, 28, AD167A/FC2143 (LP1150)2, 3, AX100
4, 31;

QLogic QLE220−E−SP4, 18, 19, 23


18 Fujitsu Siemens Primergy: RX200 SuSE SLES PCI QLogic QLA2340−E−SP16, 17 FC−AL, EMC Y
S3, RX600 S3, TX300 S3, TX600 [x86_64] 105, Express, FC−SW CLARiiON
S3; 6, 7, 8 PCI−X AX100
HPQ Proliant ML350(G4)24
19 Dell PowerEdge: 1850, 1900, 2850, SuSE SLES PCI QLogic QLE220−E−SP4, 18, 19 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; [x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 180 CLARiiON AX100


CLARiiON AX100

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
20 Dell PowerEdge 1855 SuSE SLES PCI−X Dell: 2342M16, 17, LPe1105−M2, 3, 4, 30, QME24624, 17, 36 FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100
21 Dell PowerEdge: 6800, 6850; SuSE SLES PCI−X Emulex LP101−E1, 2, 3, 4 FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
HPQ Proliant DL360(G4)24; 6, 7, 8 AX100
IBM xSeries: x336 (8837)15, x346
(8840)15, x3850/x366 (8863)43, 44
22 Fujitsu Siemens Primergy: RX200 SuSE SLES PCI−X Emulex LP1050−E2, 3, 4, 14 FC−AL, EMC Y
S2, RX300 S2, TX200 S2, TX300 [x86_64] 105, FC−SW CLARiiON
S2 6, 7, 8 AX100
23 Fujitsu Siemens Primergy RX600 S2 SuSE SLES PCI−X Emulex LP1050Ex−E2, 3, 4, 32 FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100
24 Fujitsu Siemens Primergy: RX600 SuSE SLES PCI−X Emulex LPe1150−E2, 3, 4, 30 FC−AL, EMC Y
S2, TX600 S2 [x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100
25 Fujitsu Siemens Primergy: RX300 SuSE SLES PCI−X Emulex: LP101−E2, 3, 14, LP101−E2, 3, 4, 14 FC−AL, EMC Y
S2, TX200 S2, TX300 S2 [x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100
26 Dell PowerEdge: 6800, 6850; SuSE SLES PCI−X Emulex: LP1050−E2, 3, 4, 33, LP982−E2, 3, 4 FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
IBM xSeries: x336 (8837)15,x346 6, 7, 8 AX100
(8840)15, x3850/x366 (8863)43, 44
27 HPQ Proliant DL360(G4)24 SuSE SLES PCI−X Emulex: LP1050−E2, 3, 33, LP982−E2, 3; FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
6, 7, 8 HPQ: AB429A/FC1143 (QLA2460)4, 17, 28, AD167A/FC2143 (LP1150)2, 3, AX100
4, 31

28 HPQ Proliant BL460c: SuSE SLES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(416653−B21), (416654−B21), [x86_64] 105, (403619−B21)17, 21 FC−SW CLARiiON
(416655−B21), (416656−B21), 6, 7, 8 AX100
(432636−B21);
HPQ Proliant BL480c:
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
29 Fujitsu Siemens Primergy: RX200 SuSE SLES PCI−X QLogic QLA2340−E−SP16, 17 FC−AL, EMC Y
S2, RX300 S2, RX600 S2, TX200 [x86_64] 105, FC−SW CLARiiON
S2, TX300 S2, TX600 S2; 6, 7, 8 AX100
HPQ Proliant DL360(G4)24
30 Dell PowerEdge: 1950, 6800, 6850; SuSE SLES PCI−X QLogic QLA2340−E−SP4, 16, 17 FC−AL, EMC Y
[x86_64] 105, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX600 6, 7, 8 AX100
S2, TX600 S2;
IBM xSeries: x336 (8837)15, x346
(8840)15
31 Fujitsu Siemens Primergy: RX300 SuSE SLES PCI−X QLogic QLE220−E−SP4, 18, 19, 23 FC−AL, EMC Y
S2, TX200 S2, TX300 S2; [x86_64] 105, FC−SW CLARiiON
6, 7, 8 AX100
HPQ Proliant DL360(G4)24
32 IBM xSeries: x3800/x260 (8865)43, SuSE SLES PCI−X42 Emulex: LP101−E1, 2, 3, 4, LP1050−E2, 3, 4, 33, LP982−E2, 3, 4 FC−AL, EMC Y
44,x3950/x3950E/x460 (8872, [x86_64] 105, FC−SW CLARiiON
8874)43, 44 6, 7, 8 AX100
33 Dell PowerEdge 1955 SuSE SLES PCI, PCI Dell: LPe1105−M2, 3, 4, 30, QME24624, 17, 36 FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
34 Fujitsu Siemens Primergy TX200 SuSE SLES PCI, PCI Emulex LPe1150−E2, 3, 4, 30; FC−AL, EMC Y
S3; [x86_64] 105, Express, QLogic QLA2340−E−SP16, 17 FC−SW CLARiiON
HPQ Proliant: DL380(G5), 6, 7, 8 PCI−X AX100
DL580(G4)
35 HPQ Proliant: DL380(G5), SuSE SLES PCI, PCI Emulex: LP101−E1, 2, 3, 4, LP1050−E2, 3, 33, LP982−E2, 3, LPe111−E2, 3, FC−AL, EMC Y
DL580(G4) [x86_64] 105, Express, 4, 29; FC−SW CLARiiON
6, 7, 8 PCI−X AX100
HPQ: A8002A/FC2142SR (LPe1150)2, 3, 4, 35, AB429A/FC1143
(QLA2460)4, 17, 28, AD167A/FC2143 (LP1150)2, 3, 4, 31,
AE311A/FC1142SR (QLE2460)4, 17, 22, AE312A/FC1242SR (QLE2462)4,
17, 22;

QLogic: QLE220−E−SP4, 18, 19, 23 , QLE2460−E−SP4, 17, 22,


QLE2462−E−SP4, 17, 22
36 Fujitsu Siemens Primergy TX200 S3 SuSE SLES PCI, PCI QLogic QLA2340−E−SP4, 16, 17 FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
37 Dell PowerEdge: 1800, 2800 SuSE SLES PCI, PCI QLogic QLE220−E−SP4, 18, 19 FC−AL, EMC Y
[x86_64] 105, Express, FC−SW CLARiiON
6, 7, 8 PCI−X AX100
38 Dell PowerEdge: 1800, 1850, 2600, SuSE SLES PCI, Emulex LP101−E1, 2, 3, 4 FC−AL, EMC Y
2650, 2800, 2850; [x86_64] 105, PCI−X FC−SW CLARiiON
6, 7, 8 AX100
HPQ Proliant: DL380(G4)24,
DL38524, DL580(G3)24, DL58524,
ML370(G4)24
39 Dell PowerEdge: 1800, 1850, 2600, SuSE SLES PCI, Emulex: LP1050−E2, 3, 4, 33, LP982−E2, 3, 4; FC−AL, EMC Y
2650, 2800, 2850 [x86_64] 105, PCI−X FC−SW CLARiiON
6, 7, 8 QLogic QLA2340−E−SP4, 16, 17 AX100
40 HPQ Proliant: DL380(G4)24, SuSE SLES PCI, Emulex: LP1050−E2, 3, 33, LP982−E2, 3; FC−AL, EMC Y
DL38524, DL580(G3)24, DL58524, [x86_64] 105, PCI−X FC−SW CLARiiON
ML370(G4)24 6, 7, 8 QLogic QLA2340−E−SP16, 17 AX100

11/02/2006 181 CLARiiON AX100


CLARiiON AX100

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
41 HPQ Proliant: DL380(G4)24, SuSE SLES PCI, HPQ AB429A/FC1143 (QLA2460)4, 17, 28 FC−AL, EMC Y
ML370(G4)24 [x86_64] 105, PCI−X FC−SW CLARiiON
6, 7, 8 AX100
42 HPQ Proliant: DL380(G4)24, SuSE SLES PCI, HPQ AD167A/FC2143 (LP1150)2, 3, 4, 31 FC−AL, EMC Y
DL38524, DL58524, ML370(G4)24 [x86_64] 105, PCI−X FC−SW CLARiiON
6, 7, 8 AX100
43 HPQ Proliant: DL14524, SuSE SLES PCI, QLogic QLE220−E−SP4, 18, 19, 23 FC−AL, EMC Y
DL380(G4)24, DL38524, [x86_64] 105, PCI−X FC−SW CLARiiON
DL580(G3)24, DL58524, 6, 7, 8 AX100
ML370(G4)24
44 Fujitsu Siemens Primergy RX300 S3 SuSE SLES PCI QLogic QLA2340−E−SP16, 17 FC−SW EMC Y
[x86_64] 105, Express CLARiiON
6, 7, 8 AX100
45 Fujitsu Siemens Primergy: RX200 SuSE SLES PCI QLogic QLA2340−E−SP16, 17 FC−SW EMC Y
S3, RX600 S3, TX300 S3, TX600 [x86_64] 105, Express, CLARiiON
S3 6, 7, 8 PCI−X AX100
46 IBM BladeCenter: HS20 (Model SuSE SLES PCI−X IBM HS20 4GB SFF FC Exp Card (26R0890)4, 17, 38 FC−SW EMC Y
8843), LS20 (Model 8850) [x86_64] 105, CLARiiON
6, 7, 8 AX100
47 IBM BladeCenter HS20 (Model: SuSE SLES PCI−X IBM HS20 FC Exp Card: (13N2203)4, 16, 17, (48P7061)4, 16, 17 FC−SW EMC Y
8832−N1X), 8843) [x86_64] 105, CLARiiON
6, 7, 8 AX100
48 IBM BladeCenter LS20 (Model SuSE SLES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)2, 4, 39, 40 , FC−SW EMC Y
8850) [x86_64] 105, HS20 FC Exp Card (13N2203) for IBM eServer LS204, 16, 17 CLARiiON
6, 7, 8 AX100
49 IBM BladeCenter HS20 (Model SuSE SLES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)2, 4, 39, 41 , FC−SW EMC Y
8843) [x86_64] 105, HS20 FC Exp Card (26K4841)4, 16, 17 CLARiiON
6, 7, 8 AX100
50 IBM BladeCenter HS20 (Model: SuSE SLES PCI−X IBM: Emulex LP1005DC FC Exp Card2, 3, 4, 34, HS20 4GB Standard FC FC−SW EMC Y
8832−N1X), 8843); [x86_64] 105, Exp Card (26R0884)4, 17, 37 CLARiiON
6, 7, 8 AX100
IBM BladeCenter LS20 (Model
8850)
51 Fujitsu Siemens Primergy: RX300 SuSE SLES PCI−X QLogic QLA2340−E−SP16, 17 FC−SW EMC Y
S2, RX600 S2, TX300 S2, TX600 [x86_64] 105, CLARiiON
S2 6, 7, 8 AX100
52 Fujitsu Siemens Primergy TX200 S3 SuSE SLES PCI, PCI QLogic QLA2340−E−SP16, 17 FC−SW EMC Y
[x86_64] 105, Express, CLARiiON
6, 7, 8 PCI−X AX100
1. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. Driver Version 8.1.6 Driver is integrated into the kernel.
3. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
4. SNIA HBA API Supported.
5. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
6. Native multipathing is not supported on boot−from−SAN configurations.
7. Supported kernels: 2.6.16.21−0.8.
Confirm kernel support with server vendor.
8. SGI's XFS filesystem is supported.
9. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
10. VxVM is not supported on servers booting from the array.
11. BIOS 6.00a1
12. Firmware Version 2.50a8
13. Driver Version 8.1.6
14. Firmware Version 1.91a1
15. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
16. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 8.01.04−k Driver is integrated into the kernel.
18. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
19. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
20. Driver Version 8.01.04−k
21. BIOS 1.16
22. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Driver/BIOS are available at http://www.qlogic.com
24. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
25. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
26. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
27. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
28. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
29. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. Firmware Version 2.50a6
31. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. Firmware Version 1.91a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
33. Firmware Version 1.91a5
34. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
36. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
38. BIOS 1.12
39. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
40. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
41. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. Accepts PCI−X 1.0 and 2.0 HBAs.
43. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
44. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.

Sun Solaris

11/02/2006 182 CLARiiON AX100


CLARiiON AX100

Sun Solaris
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex: LP10000−E2, 6, 10, 11, 14, 16, 37, 38, 39, 40, 41, 42, 43 , LP9002−E FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris (LP9002L−E)2, 6, 10, 11, 14, 16, 37, 39, 41, 42, 44, 45 , LP9802−E2, 6, 10, 11, FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 103, 4, 5 14, 16, 37, 38, 39, 40, 41, 42, 43 ; AX100
QLogic QLA2340−E−SP2, 6, 8, 16, 31, 32, 33, 34, 35, 36 ;
Sun SG−XPCI1FC−EM2 (LP10000)2, 10, 11, 14, 37
2 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Sun: SG−XPCI1FC−QL2 (QLA2340)2, 6, 8, 16, 21, 22, 23, 24, 25, 26, 27, FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 28, 29, 30 , X6767A (SG−XPCI1FC−QF2)2, 6, 7, 8 FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 103, 4, 5 AX1001
3 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex LP8000−EMC6, 41, 42, 46, 47, 48, 49 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 104, 5 AX100
4 Sun Sun Fire: 4800, 6800 Sun PCI Emulex LP9002C−E2, 6, 10, 37, 40, 41, 42, 44, 46, 47 FC−AL, EMC N
Solaris FC−SW CLARiiON
104, 5 AX100
5 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP8, 9, 12, 13, 16, 18, 31, 33, 34, 35, 36, 50 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 8 FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 AX1001
6 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−QL2 (QLA2340)6, 8, 9, 12, 13, 21 , X6767A FC−AL, EMC N
Solaris 8 (SG−XPCI1FC−QF2)2, 6, 7, 8, 9, 12, 13 FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, AX1001
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R20, 250, 420R20, 450
7 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun SG−XPCI1FC−EM2 (LP10000)2, 9, 10, 11, 12, 13, 14, 16, 18 FC−AL, EMC N
Solaris FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, 819 AX1001
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R20, 250, 420R20, 450
8 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP8, 9, 12, 13, 16, 18, 31, 33, 34, 35, 36, 50 ; FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 9 Sun: SG−XPCI1FC−EM2 (LP10000)2, 9, 10, 11, 12, 13, 14, 16, 17, 18 , FC−SW CLARiiON
V250, V480, V490, V880, V890 SG−XPCI1FC−QL2 (QLA2340)6, 8, 9, 12, 13, 21 , X6767A AX1001
(SG−XPCI1FC−QF2)2, 6, 7, 8, 9, 12, 13, 17
9 Sun Sun Fire V440 Sun PCI QLogic QLA2340−E−SP8, 9, 12, 13, 16, 18, 31, 33, 34, 35, 36, 50 FC−AL, EMC N
Solaris FC−SW CLARiiON
915 AX1001
10 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−EM2 (LP10000)2, 9, 10, 11, 12, 13, 14, 16, 17, 18 , FC−AL, EMC N
Solaris SG−XPCI1FC−QL2 (QLA2340)6, 8, 9, 12, 13, 21 , X6767A FC−SW CLARiiON
Sun Sun Fire: V210, V440; 915 (SG−XPCI1FC−QF2)2, 6, 7, 8, 9, 12, 13, 17 AX1001

Sun Ultra: 220R20, 250, 420R20, 450


1. AX100 requires the following minimum Flare revs:
AX100 02.16.102.5.004
AX100SC 02.16.101.5.004
2. STMS is Sun's Multipathing Software and not an EMC Software product. Please refer to the required release note "SUN StorEdge Traffic Manager for CLARiiON Release Notes", P/N
300−002−978, which can be found on EMC's Powerlink website in Support −> Document Library −> Host Connectivity for the complete Installation information.
3. STMS (MPxIO) is supported with the following patch installed: 119715−09
4. If setting the boot disk from SAN with Solaris 10, its Target/LUN must be defined in the /kernel/drv/sd.conf file.
5. EMC requres Sun patches for Solaris 10:
118822−30 SunOS 5.10: Kernel patch
118833−24 SunOS 5.10: Kernel patch
119130−26 SunOS 5.10: Sun Fibre Channel Device Drivers (only necessary for Leadville Stack driver)
120222−11 SunOS 5.10: Emulex−Sun LightPulse fibre channel adapter driver (only requred for Emulex HBAs)
6. SNIA HBA API Supported.
7. FCode Value 1.14.11
8. FCode Value 1.14.15
9. Driver Version SAN 4.4.10
10. FCode Value 1.50a4
11. FCode Value 1.50a8
12. Driver Version SAN 4.4.9
13. Driver Version SAN 4.4.11
14. FCode Value 1.50a9
15. EMC required Sun patches for Solaris 9:
112233−12 SunOS 5.9: kernel patch
117171−17 SunOS 5.9: kernel patch
118558−34 SunOS 5.9: kernel patch
112834−06 SunOS 5.9: patch SCSI
113277−47 SunOS 5.9: sd and ssd patch
16. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
Driver version SAN 4.3 or older is not supported for MPxIO on EMC Symmetrix storage. MPxIO is not supported on EMC CLARiiON storage with Solaris 8.
17. Sun StorEdge Traffic Manager Software (Sun's Native Multipathing Software) is supported on CLARiiON with SAN 4.4.7a and above.
18. For servers running Solaris 8 or 9 with the Sun SAN driver, the following applies:
Must add "set fcp:ssfcp_enable_auto_configuration=1" (do not include quote marks) in /etc/system to fix the following problems:
1. VxVM − rootdg can not be imported during boot
2. SVM − Volume Manager can not be started after system boot
3. PowerPath 4.x − error message "All paths to (array type) (array name) vol(volume number) are dead"
19. SDS support on Solaris 8 requires minimum SDS version 4.2.1 with patch 108693−16 or later version.
20. 64−bit HBAs will not fit into the 32−bit slot due to a physical obstruction.
21. FCode Value 1.14.09
22. Driver Version SAN 4.4.6
23. Driver Version SAN 4.4.4
24. Driver Version SAN 4.4.3
25. Driver Version SAN 4.4.2
26. Driver Version SAN 4.4.1
27. Driver Version 4.4.4
28. Driver Version 4.4.3
29. Driver Version SAN 4.4.8
30. Driver Version SAN 4.4.7a
31. Driver Version 4.17
32. Driver Version S10 Update 1 (01/06)
33. Driver Version 4.22
34. FCode Value 1.14.13
35. FCode Value 2.00.09

11/02/2006 183 CLARiiON AX100


CLARiiON AX100

36. FCode Value 2.00.06


37. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
38. Firmware Version 1.91a5
39. Driver Version 6.10g
40. Driver Version SAN in Solaris 10 U1 (01/06)
41. Driver Version 6.02hx2
42. Driver Version 6.02f
43. Firmware Version 1.91a1
44. Firmware Version 3.92a3
45. Firmware Version 3.93a0
46. Driver Version 6.02e
47. FCode Value 1.41a4
48. Firmware Version 3.92a2
49. The LP8000−EMC HBA has a permanent GBIC, and does not have copper cable support.
50. Driver Version 4.15.03

VMware ESX Server

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 HPQ Proliant DL380(G3)40 VMware ESX Server v3.0.11, 2, PCI Emulex: LP1050−E8, 24, 32, LP982−E24, 30, 31; FC−AL, EMC Y7, 25
4, 16, 20 FC−SW CLARiiON
QLogic QLA2340−E−SP26, 33 AX100
2 Fujitsu Siemens Primergy BX66038 VMware ESX Server v3.0.11, 2, PCI Fujitsu Siemens BX600−FC22Q13, 22, 26, 37 FC−AL, EMC Y7, 25
4, 16, 20 FC−SW CLARiiON
AX100
3 Fujitsu Siemens Primergy RX300 S3 VMware ESX Server v3.0.11, 2, PCI Emulex LP1050Ex−E8, 22, 24, 31 ; FC−AL, EMC Y7, 25
4, 16, 20 Express QLogic QLA2340−E−SP26 FC−SW CLARiiON
AX100
4 Dell PowerEdge: 1950, 6850; VMware ESX Server v3.0.11, 2, PCI Emulex LP1050Ex−E8, 9, 22, 24 FC−AL, EMC Y7, 25
4, 16, 20 Express FC−SW CLARiiON
Fujitsu Siemens Primergy RX300 S3 AX100
5 Dell PowerEdge 1950 VMware ESX Server v3.0.11, 2, PCI Emulex: LP1050−E8, 24, 32, LP982−E24, 30, 31; FC−AL, EMC Y7, 25
4, 16, 20 Express FC−SW CLARiiON
QLogic QLE2360−E−SP22, 26, 29 AX100
6 Dell PowerEdge 1950; VMware ESX Server v3.0.11, 2, PCI QLogic QLA2340−E−SP26, 33 FC−AL, EMC Y7, 25
Fujitsu Siemens Primergy RX300 S3 4, 16, 20 Express FC−SW CLARiiON
AX100
7 Dell PowerEdge 6850 VMware ESX Server v3.0.11, 2, PCI QLogic QLE2360−E−SP22, 26 FC−AL, EMC Y7, 25
4, 16, 20 Express FC−SW CLARiiON
AX100
8 Dell PowerEdge 6850 VMware ESX Server v3.0.11, 2, PCI Dell 2362M26, 47, 48 FC−AL, EMC Y7, 25
4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
9 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.11, 2, PCI Emulex LP1050−E8, 24, 32 FC−AL, EMC Y7, 25
2950, 6850, 6950; 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
IBM xSeries: x336 (8837)50, x3550
(7978), x3650 (7979), x3755 (8877)
10 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server v3.0.11, 2, PCI Emulex LP1050Ex−E8, 22, 24, 31 FC−AL, EMC Y7, 25
IBM: eServer 326m (Model 7969), 4, 16, 20 Express, FC−SW CLARiiON
xSeries x3755 (8877) PCI−X AX100
11 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.11, 2, PCI Emulex LP1050Ex−E8, 9, 22, 24 FC−AL, EMC Y7, 25
2950, 6850, 6950; 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
Fujitsu Siemens Primergy TX300 S3;
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)50, xSeries x3755
(8877)
12 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.11, 2, PCI Emulex LP982−E24, 30, 31 FC−AL, EMC Y7, 25
2950, 6850, 6950; 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
IBM xSeries: x336 (8837)50, x3550
(7978), x3650 (7979)
13 Dell PowerEdge: 2900, 2950, 6950; VMware ESX Server v3.0.11, 2, PCI Emulex LPe1150−E8, 22, 23, 24 FC−AL, EMC Y7, 25
4, 16, 20 Express, FC−SW CLARiiON
Fujitsu Siemens Primergy RX600 S3 PCI−X AX100
14 IBM xSeries x3755 (8877) VMware ESX Server v3.0.11, 2, PCI Emulex: LP1050−E8, 22, 24, 31 , LP1050−E8, 24, 31 FC−AL, EMC Y7, 25
4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
15 IBM xSeries: x3550 (7978), x3650 VMware ESX Server v3.0.11, 2, PCI IBM 24P0960 (QLA2340)13, 26, 36 FC−AL, EMC Y7, 25
(7979), x3755 (8877) 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
16 NEC Express 5800 120Ri−2 VMware ESX Server v3.0.11, 2, PCI NEC N8190−120 (LP1050)6, 8, 9, 24 FC−AL, EMC Y7, 25
4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
17 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server v3.0.11, 2, PCI QLogic QLA2340−E−SP26 FC−AL, EMC Y7, 25
IBM xSeries x3755 (8877) 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
18 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.11, 2, PCI QLogic QLA2340−E−SP26, 33 FC−AL, EMC Y7, 25
2950, 6850, 6950; 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
Fujitsu Siemens Primergy TX300 S3;
IBM xSeries: x336 (8837)50, x346
(8840)50, x3550 (7978), x3650 (7979),
x3755 (8877)

11/02/2006 184 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
19 IBM: eServer 326m (Model 7969), VMware ESX Server v3.0.11, 2, PCI QLogic QLE2360−E−SP22, 26 FC−AL, EMC Y7, 25
xSeries x3755 (8877) 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
20 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.11, 2, PCI QLogic QLE2360−E−SP22, 26, 29 FC−AL, EMC Y7, 25
2950, 6950; 4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
IBM: eServer 326m (Model 7969),
xSeries x3755 (8877)
21 Dell PowerEdge: 2900, 2950, 6950; VMware ESX Server v3.0.11, 2, PCI QLogic QLE2460−E−SP22, 26, 27 FC−AL, EMC Y
4, 16, 20 Express, FC−SW CLARiiON
IBM: eServer 326m (Model 7969), PCI−X AX100
xSeries x3755 (8877)
22 Dell PowerEdge 1855 VMware ESX Server v3.0.11, 2, PCI−X Dell 2342M13, 26 FC−AL, EMC Y7, 25
4, 16, 20 FC−SW CLARiiON
AX100
23 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server v3.0.11, 2, PCI−X Emulex LP1050−E8, 22, 24, 31 FC−AL, EMC Y7, 25
4, 16, 20 FC−SW CLARiiON
AX100
24 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server v3.0.11, 2, PCI−X Emulex LP1050Ex−E8, 22, 24, 31 FC−AL, EMC Y7, 25
TX600 S2 4, 16, 20 FC−SW CLARiiON
AX100
25 HPQ Proliant DL360(G4)40 VMware ESX Server v3.0.11, 2, PCI−X Emulex LP1050Ex−E8, 9, 22, 24 FC−AL, EMC Y7, 25
4, 16, 20 FC−SW CLARiiON
AX100
26 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server v3.0.11, 2, PCI−X Emulex: LP1050−E8, 24, 32, LP982−E24, 30, 31 FC−AL, EMC Y7, 25
6650; 4, 16, 20 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL74040, DL760 (G2)40,
ML570(G2)40, ML570(G3)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)43;
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun: V40z, x4100, x4200
27 HPQ Proliant BL45p VMware ESX Server v3.0.11, 2, PCI−X HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
4, 16, 20 Proliant BL25p/BL45p 381881−B2126, 51, FC−SW CLARiiON
Emulex−based BL25/30/35/45p Fibre Channel AX100
Mezzanine HBA − 394588−B2124
28 IBM xSeries: x235, x365, x3850/x366 VMware ESX Server v3.0.11, 2, PCI−X IBM 24P0960 (QLA2340)13, 26, 36 FC−AL, EMC Y7, 25
(8863)43 4, 16, 20 FC−SW CLARiiON
AX100
29 NEC Express 5800: 120Rh−2, VMware ESX Server v3.0.11, 2, PCI−X NEC N8190−120 (LP1050)6, 8, 9, 24 FC−AL, EMC Y7, 25
140Rd−4 4, 16, 20 FC−SW CLARiiON
AX100
30 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server v3.0.11, 2, PCI−X QLogic QLA2340−E−SP26 FC−AL, EMC Y7, 25
TX600 S2; 4, 16, 20 FC−SW CLARiiON
AX100
Sun: V40z, x4100, x4200
31 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server v3.0.11, 2, PCI−X QLogic QLA2340−E−SP26, 33 FC−AL, EMC Y7, 25
6650; 4, 16, 20 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: RX600 S2,
TX600 S2;
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL74040, DL760 (G2)40,
ML570(G2)40, ML570(G3)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)43;
Sun: V40z, x4100, x4200
32 HPQ Proliant BL20p (G2) VMware ESX Server v3.0.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
4, 16, 20 Proliant BL20p (G2) 300874−B2119, 26 FC−SW CLARiiON
AX100
33 HPQ Proliant BL25p VMware ESX Server v3.0.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
4, 16, 20 Proliant BL25p/BL45p 381881−B2126, 51 FC−SW CLARiiON
AX100
34 HPQ Proliant: BL25p, BL35p VMware ESX Server v3.0.11, 2, PCI−X18 HPQ Emulex−based BL25/30/35/45p Fibre Channel FC−AL, EMC Y7, 25
4, 16, 20 Mezzanine HBA − 394588−B2124 FC−SW CLARiiON
AX100
35 HPQ Proliant BL20p (G3) VMware ESX Server v3.0.11, 2, PCI−X18 HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
4, 16, 20 Proliant BL20p (G3) 361426−B2119, 26, FC−SW CLARiiON
Emulex−based BL20p (G3) Fibre Channel AX100
Mezzanine HBA − 394757−B2124
36 IBM xSeries: x3800/x260 (8865)43, VMware ESX Server v3.0.11, 2, PCI−X42 Emulex: LP1050−E8, 24, 32, LP982−E24, 30, 31; FC−AL, EMC Y7, 25
x3950/x3950E/x460 (8872, 8874)43 4, 16, 20 FC−SW CLARiiON
IBM 24P0960 (QLA2340)13, 26, 36; AX100
QLogic QLA2340−E−SP26, 33
37 Dell PowerEdge 1955 VMware ESX Server v3.0.11, 2, PCI, PCI Dell 2342M13, 26 FC−AL, EMC Y7, 25
4, 16, 20 Express, FC−SW CLARiiON
PCI−X AX100
38 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v3.0.11, 2, PCI, PCI Emulex: LP1050−E8, 24, 32, LP1050Ex−E8, 9, 22, 24 , FC−AL, EMC Y7, 25
4, 16, 20 Express, LP982−E24, 30, 31; FC−SW CLARiiON
PCI−X AX100
QLogic QLA2340−E−SP26, 33

11/02/2006 185 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
39 HPQ Proliant: DL380(G4)40, VMware ESX Server v3.0.11, 2, PCI, Emulex LP1050Ex−E8, 9, 22, 24 FC−AL, EMC Y7, 25
DL580(G3)40 4, 16, 20 PCI−X FC−SW CLARiiON
AX100
40 Fujitsu Siemens Primergy: RX600, VMware ESX Server v3.0.11, 2, PCI, Emulex: LP1050−E8, 22, 24, 31 , LP1050−E8, 24, 31; FC−AL, EMC Y7, 25
TX600 4, 16, 20 PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP26 AX100
41 HPQ Proliant: DL380(G4)40, DL38540, VMware ESX Server v3.0.11, 2, PCI, Emulex: LP1050−E8, 24, 32, LP982−E24, 30, 31 FC−AL, EMC Y7, 25
DL580(G2)40, DL580(G3)40, DL58540, 4, 16, 20 PCI−X FC−SW CLARiiON
ML370(G3)40, ML370(G4)40; AX100
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
42 IBM: eServer 325 (Model 8835), VMware ESX Server v3.0.11, 2, PCI, IBM 24P0960 (QLA2340)13, 26, 36 FC−AL, EMC Y7, 25
xSeries x445 (8870) 4, 16, 20 PCI−X FC−SW CLARiiON
AX100
43 Fujitsu Siemens Primergy: RX600, VMware ESX Server v3.0.11, 2, PCI, QLogic QLA2340−E−SP26, 33 FC−AL, EMC Y7, 25
TX600; 4, 16, 20 PCI−X FC−SW CLARiiON
AX100
HPQ Proliant: DL380(G4)40, DL38540,
DL580(G2)40, DL580(G3)40, DL58540,
ML370(G3)40, ML370(G4)40;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
44 HPQ Proliant: DL380(G3)40, VMware ESX Server: v3.0.11, 2, PCI HPQ AD167A/FC2143 (LP1150)8, 22, 24, 41 FC−AL, EMC Y7, 25
DL580(G2)40 4, 16, 20, v3.01, 2, 4, 16, 20, 21 , FC−SW CLARiiON
v3.01, 2, 4, 20, 21 AX100
45 Dell PowerEdge: 1850, 1950, 2800, VMware ESX Server: v3.0.11, 2, PCI Emulex LPe1150−E8, 22, 23, 24 FC−AL, EMC Y7, 25
2850, 6800, 6850; 4, 16, 20, v3.01, 2, 4, 16, 20, 21 , Express FC−SW CLARiiON
v3.01, 2, 4, 20, 21 AX100
HPQ Proliant: DL360(G4)40,
DL380(G4)40, DL580(G3)40,
ML370(G4)40
46 HPQ Proliant: DL360(G4)40, VMware ESX Server: v3.0.11, 2, PCI HPQ: A8002A/FC2142SR (LPe1150)8, 22, 24, 34 , FC−AL, EMC Y7, 25
DL380(G4)40, DL580(G3)40, 4, 16, 20, v3.01, 2, 4, 16, 20, 21 , Express AD167A/FC2143 (LP1150)8, 22, 24, 41 FC−SW CLARiiON
ML370(G4)40 v3.01, 2, 4, 20, 21 AX100
47 HPQ Proliant DL360(G4)40 VMware ESX Server: v3.0.11, 2, PCI HPQ AD167A/FC2143 (LP1150)8, 22, 24, 41 FC−AL, EMC Y7, 25
4, 16, 20, v3.01, 2, 4, 16, 20, 21 , Express, FC−SW CLARiiON
v3.01, 2, 4, 20, 21 PCI−X AX100
48 NEC Express 5800: 120Ri−2, 140Rd−4 VMware ESX Server: v3.0.11, 2, PCI NEC N8190−127 (LPe1150)6, 24, 34, 35 FC−AL, EMC Y7, 25
4, 16, 20, v3.01, 2, 4, 16, 20, 21 , Express, FC−SW CLARiiON
v3.01, 2, 4, 20, 21 PCI−X AX100
49 Dell PowerEdge 1855 VMware ESX Server: v3.0.11, 2, PCI−X Dell LPe1105−M8, 22, 23, 24 FC−AL, EMC Y7, 25
4, 16, 20, v3.01, 2, 4, 16, 20, 21 , FC−SW CLARiiON
v3.01, 2, 4, 20, 21 AX100
50 HPQ Proliant: BL40p, DL360(G3)40, VMware ESX Server: v3.0.11, 2, PCI−X HPQ AD167A/FC2143 (LP1150)8, 22, 24, 41 FC−AL, EMC Y7, 25
DL360(G4)40, DL74040, DL760 (G2)40, 4, 16, 20, v3.01, 2, 4, 16, 20, 21 , FC−SW CLARiiON
ML570(G2)40 v3.01, 2, 4, 20, 21 AX100
51 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server: v3.0.11, 2, PCI, PCI Emulex LPe1150−E8, 22, 23, 24 ; FC−AL, EMC Y7, 25
4, 16, 20, v3.01, 2, 4, 16, 20, 21 , Express, HPQ: A8002A/FC2142SR (LPe1150)8, 22, 24, 34 , FC−SW CLARiiON
v3.01, 2, 4, 20, 21 PCI−X AD167A/FC2143 (LP1150)8, 22, 24, 41 AX100
52 HPQ Proliant: DL380(G3)40, VMware ESX Server: v3.0.11, 2, PCI, HPQ AD167A/FC2143 (LP1150)8, 22, 24, 41 FC−AL, EMC Y7, 25
DL380(G4)40, DL38540, DL580(G2)40, 4, 16, 20, v3.01, 2, 4, 16, 20, 21 , PCI−X FC−SW CLARiiON
DL580(G3)40, ML370(G3)40, v3.01, 2, 4, 20, 21 AX100
ML370(G4)40
53 Dell PowerEdge 1955 VMware ESX Server: v3.0.11, 2, PCI, PCI Dell LPe1105−M8, 22, 24 FC−AL, EMC Y7, 25
4, 16, 20, v3.01, 2, 4, 16, 20, 21 , Express, FC−SW CLARiiON
v3.01, 2, 4, 20, 21 , v3.02, 4, 16, 20, PCI−X AX100
21, v3.02, 4, 20, 21

54 Dell PowerEdge: 1850, 1950, 2800, VMware ESX Server: v3.0.11, 2, PCI QLogic QLE2460−E−SP22, 26, 27 FC−AL, EMC Y
2850, 6800, 6850 4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, Express FC−SW CLARiiON
4, 20, 21 AX100
55 HPQ Proliant DL360(G4)40 VMware ESX Server: v3.0.11, 2, PCI−X HPQ AB429A/FC1143 (QLA2460)22, 26, 53 FC−AL, EMC Y7, 25
4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, FC−SW CLARiiON
4, 20, 21 AX100
56 HPQ Proliant DL380(G5) VMware ESX Server: v3.0.11, 2, PCI, PCI HPQ AB429A/FC1143 (QLA2460)22, 26, 53 FC−AL, EMC Y7, 25
4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, Express, FC−SW CLARiiON
4, 20, 21 PCI−X AX100
57 HPQ Proliant: DL380(G4)40, DL38540, VMware ESX Server: v3.0.11, 2, PCI, HPQ AB429A/FC1143 (QLA2460)22, 26, 53 FC−AL, EMC Y7, 25
DL58540, ML370(G4)40 4, 16, 20, v3.02, 4, 16, 20, 21 , v3.02, PCI−X FC−SW CLARiiON
4, 20, 21 AX100
58 Dell PowerEdge: 2900, 2950; VMware ESX Server: v3.01, 2, 4, PCI Emulex LPe1150−E8, 22, 23, 24 FC−AL, EMC Y7, 25
16, 20, 21 , v3.01, 2, 4, 20, 21 Express, FC−SW CLARiiON
Fujitsu Siemens Primergy RX600 S3 PCI−X AX100
59 Dell PowerEdge 1955 VMware ESX Server: v3.01, 2, 4, PCI, PCI Dell 2342M12, 13 FC−AL, EMC Y7, 25
16, 20, 21 , v3.01, 2, 4, 20, 21 , v3.02, Express, FC−SW CLARiiON
4, 16, 20, 21 , v3.02, 4, 20, 21 PCI−X AX100
60 HPQ Proliant DL380(G3)40 VMware ESX Server: v3.02, 4, 16, PCI Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31; FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
QLogic QLA2340−E−SP12, 33 AX100
61 Fujitsu Siemens Primergy BX66038 VMware ESX Server: v3.02, 4, 16, PCI Fujitsu Siemens BX600−FC22Q12, 13, 22, 37 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
62 Fujitsu Siemens Primergy RX300 S3 VMware ESX Server: v3.02, 4, 16, PCI Emulex LP1050Ex−E8, 22, 28, 31 ; FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express QLogic QLA2340−E−SP12 FC−SW CLARiiON
AX100

11/02/2006 186 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
63 Dell PowerEdge: 1950, 6850; VMware ESX Server: v3.02, 4, 16, PCI Emulex LP1050Ex−E8, 9, 22, 28 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express FC−SW CLARiiON
Fujitsu Siemens Primergy RX300 S3 AX100
64 Dell PowerEdge 1950 VMware ESX Server: v3.02, 4, 16, PCI Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31; FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express FC−SW CLARiiON
QLogic QLE2360−E−SP12, 22, 29 AX100
65 Dell PowerEdge 1950; VMware ESX Server: v3.02, 4, 16, PCI QLogic QLA2340−E−SP12, 33 FC−AL, EMC Y7, 25
Fujitsu Siemens Primergy RX300 S3 20, 21, v3.02, 4, 20, 21 Express FC−SW CLARiiON
AX100
66 Dell PowerEdge 6850 VMware ESX Server: v3.02, 4, 16, PCI QLogic QLE2360−E−SP12, 22 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express FC−SW CLARiiON
AX100
67 Dell PowerEdge 6850 VMware ESX Server: v3.02, 4, 16, PCI Dell 2362M12, 47, 48 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
68 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server: v3.02, 4, 16, PCI Emulex LP1050Ex−E8, 22, 28, 31 FC−AL, EMC Y7, 25
IBM eServer 326m (Model 7969) 20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
69 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.02, 4, 16, PCI Emulex LP1050Ex−E8, 9, 22, 28 FC−AL, EMC Y7, 25
2950, 6850; 20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
Fujitsu Siemens Primergy TX300 S3;
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)50
70 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.02, 4, 16, PCI Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31 FC−AL, EMC Y7, 25
2950, 6850; 20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
IBM xSeries: x336 (8837)50, x3550
(7978), x3650 (7979)
71 IBM xSeries: x3550 (7978), x3650 VMware ESX Server: v3.02, 4, 16, PCI IBM 24P0960 (QLA2340)12, 13, 36 FC−AL, EMC Y7, 25
(7979) 20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
72 NEC Express 5800 120Ri−2 VMware ESX Server: v3.02, 4, 16, PCI NEC N8190−120 (LP1050)6, 8, 9, 28 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
73 Fujitsu Siemens Primergy TX300 S3 VMware ESX Server: v3.02, 4, 16, PCI QLogic QLA2340−E−SP12 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
74 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.02, 4, 16, PCI QLogic QLA2340−E−SP12, 33 FC−AL, EMC Y7, 25
2950, 6850; 20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
Fujitsu Siemens Primergy TX300 S3;
IBM xSeries: x336 (8837)50, x346
(8840)50, x3550 (7978), x3650 (7979)
75 IBM eServer 326m (Model 7969) VMware ESX Server: v3.02, 4, 16, PCI QLogic QLE2360−E−SP12, 22 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
76 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.02, 4, 16, PCI QLogic QLE2360−E−SP12, 22, 29 FC−AL, EMC Y7, 25
2950; 20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
PCI−X AX100
IBM eServer 326m (Model 7969)
77 Dell PowerEdge: 2900, 2950; VMware ESX Server: v3.02, 4, 16, PCI QLogic QLE2460−E−SP22, 26, 27 FC−AL, EMC Y
20, 21, v3.02, 4, 20, 21 Express, FC−SW CLARiiON
IBM eServer 326m (Model 7969) PCI−X AX100
78 Dell PowerEdge 1855 VMware ESX Server: v3.02, 4, 16, PCI−X Dell 2342M12, 13 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
79 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server: v3.02, 4, 16, PCI−X Emulex LP1050−E8, 22, 28, 31 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
80 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server: v3.02, 4, 16, PCI−X Emulex LP1050Ex−E8, 22, 28, 31 FC−AL, EMC Y7, 25
TX600 S2 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
81 HPQ Proliant DL360(G4)40 VMware ESX Server: v3.02, 4, 16, PCI−X Emulex LP1050Ex−E8, 9, 22, 28 FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
82 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server: v3.02, 4, 16, PCI−X Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31 FC−AL, EMC Y7, 25
6650; 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL74040, DL760 (G2)40,
ML570(G2)40, ML570(G3)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)43;
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun: V40z, x4100, x4200
83 HPQ Proliant BL45p VMware ESX Server: v3.02, 4, 16, PCI−X HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Proliant BL25p/BL45p 381881−B2112, 51, FC−SW CLARiiON
Emulex−based BL25/30/35/45p Fibre Channel AX100
Mezzanine HBA − 394588−B2128
84 IBM xSeries: x235, x365, x3850/x366 VMware ESX Server: v3.02, 4, 16, PCI−X IBM 24P0960 (QLA2340)12, 13, 36 FC−AL, EMC Y7, 25
(8863)43 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100

11/02/2006 187 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
85 NEC Express 5800: 120Rh−2, VMware ESX Server: v3.02, 4, 16, PCI−X NEC N8190−120 (LP1050)6, 8, 9, 28 FC−AL, EMC Y7, 25
140Rd−4 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
86 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server: v3.02, 4, 16, PCI−X QLogic QLA2340−E−SP12 FC−AL, EMC Y7, 25
TX600 S2; 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
Sun: V40z, x4100, x4200
87 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server: v3.02, 4, 16, PCI−X QLogic QLA2340−E−SP12, 33 FC−AL, EMC Y7, 25
6650; 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
AX100
Fujitsu Siemens Primergy: RX600 S2,
TX600 S2;
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL74040, DL760 (G2)40,
ML570(G2)40, ML570(G3)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)43;
Sun: V40z, x4100, x4200
88 HPQ Proliant BL20p (G2) VMware ESX Server: v3.02, 4, 16, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Proliant BL20p (G2) 300874−B2112, 19 FC−SW CLARiiON
AX100
89 HPQ Proliant BL25p VMware ESX Server: v3.02, 4, 16, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Proliant BL25p/BL45p 381881−B2112, 51 FC−SW CLARiiON
AX100
90 HPQ Proliant: BL25p, BL35p VMware ESX Server: v3.02, 4, 16, PCI−X18 HPQ Emulex−based BL25/30/35/45p Fibre Channel FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Mezzanine HBA − 394588−B2128 FC−SW CLARiiON
AX100
91 HPQ Proliant BL20p (G3) VMware ESX Server: v3.02, 4, 16, PCI−X18 HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Proliant BL20p (G3) 361426−B2112, 19, FC−SW CLARiiON
Emulex−based BL20p (G3) Fibre Channel AX100
Mezzanine HBA − 394757−B2128
92 IBM xSeries: x3800/x260 (8865)43, VMware ESX Server: v3.02, 4, 16, PCI−X42 Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31; FC−AL, EMC Y7, 25
x3950/x3950E/x460 (8872, 8874)43 20, 21, v3.02, 4, 20, 21 FC−SW CLARiiON
IBM 24P0960 (QLA2340)12, 13, 36; AX100
QLogic QLA2340−E−SP12, 33
93 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server: v3.02, 4, 16, PCI, PCI Emulex: LP1050−E8, 28, 32, LP1050Ex−E8, 9, 22, 28 , FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Express, LP982−E28, 30, 31; FC−SW CLARiiON
PCI−X AX100
QLogic QLA2340−E−SP12, 33
94 HPQ Proliant: DL380(G4)40, VMware ESX Server: v3.02, 4, 16, PCI, Emulex LP1050Ex−E8, 9, 22, 28 FC−AL, EMC Y7, 25
DL580(G3)40 20, 21, v3.02, 4, 20, 21 PCI−X FC−SW CLARiiON
AX100
95 Fujitsu Siemens Primergy: RX600, VMware ESX Server: v3.02, 4, 16, PCI, Emulex: LP1050−E8, 22, 28, 31 , LP1050−E8, 28, 31; FC−AL, EMC Y7, 25
TX600 20, 21, v3.02, 4, 20, 21 PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP12 AX100
96 HPQ Proliant: DL380(G4)40, DL38540, VMware ESX Server: v3.02, 4, 16, PCI, Emulex: LP1050−E8, 28, 32, LP982−E28, 30, 31 FC−AL, EMC Y7, 25
DL580(G2)40, DL580(G3)40, DL58540, 20, 21, v3.02, 4, 20, 21 PCI−X FC−SW CLARiiON
ML370(G3)40, ML370(G4)40; AX100
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
97 IBM: eServer 325 (Model 8835), VMware ESX Server: v3.02, 4, 16, PCI, IBM 24P0960 (QLA2340)12, 13, 36 FC−AL, EMC Y7, 25
xSeries x445 (8870) 20, 21, v3.02, 4, 20, 21 PCI−X FC−SW CLARiiON
AX100
98 Fujitsu Siemens Primergy: RX600, VMware ESX Server: v3.02, 4, 16, PCI, QLogic QLA2340−E−SP12, 33 FC−AL, EMC Y7, 25
TX600; 20, 21, v3.02, 4, 20, 21 PCI−X FC−SW CLARiiON
AX100
HPQ Proliant: DL380(G4)40, DL38540,
DL580(G2)40, DL580(G3)40, DL58540,
ML370(G3)40, ML370(G4)40;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
99 HPQ Proliant BL35p VMware ESX Server v3.0.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
4, 16, 20 Proliant BL30p/BL35p 354054−B2119, 26 FC−SW55 CLARiiON
AX100
100 HPQ Proliant BL35p VMware ESX Server: v3.02, 4, 16, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y7, 25
20, 21, v3.02, 4, 20, 21 Proliant BL30p/BL35p 354054−B2112, 19 FC−SW55 CLARiiON
AX100
101 Fujitsu Siemens Primergy BX620: VMware ESX Server v2.5.11, 2, PCI Fujitsu Siemens BX600−FC22Q12, 13, 22, 37 FC−SW EMC Y7, 25
S2F38, S238; 3, 4, 5 CLARiiON
AX10011
Fujitsu Siemens Primergy: BX62038,
BX66038
102 Dell PowerEdge: 1550, 255044, 6450; VMware ESX Server v2.5.11, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
3, 4, 5 CLARiiON
HPQ Proliant: DL360(G2)40, DL36040, AX10011
DL380(G3)40, DL58040;
IBM xSeries: x330, x335;
NEC Express 5800 140Hd
103 Dell PowerEdge 685054 VMware ESX Server v2.5.11, 2, PCI QLogic QLE2360−E−SP12, 22, 46 FC−SW EMC Y7, 25
3, 4, 5 Express CLARiiON
AX10011

11/02/2006 188 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
104 Dell PowerEdge 685054 VMware ESX Server v2.5.11, 2, PCI Dell 2362M12, 47, 48 FC−SW EMC Y7, 25
3, 4, 5 Express, CLARiiON
PCI−X AX10011
105 Dell PowerEdge: 185054, 285054, VMware ESX Server v2.5.11, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
685054; 3, 4, 5 Express, CLARiiON
PCI−X AX10011
IBM xSeries: x336 (8837)50, x346
(8840)50
106 Dell PowerEdge: 185054, 285054 VMware ESX Server v2.5.11, 2, PCI QLogic QLE2360−E−SP12, 22, 29, 46 FC−SW EMC Y7, 25
3, 4, 5 Express, CLARiiON
PCI−X AX10011

107 Dell PowerEdge 185554 VMware ESX Server v2.5.11, 2, PCI−X Dell 2342M12, 13 FC−SW EMC Y7, 25
3, 4, 5 CLARiiON
AX10011

108 HPQ Proliant BL45p VMware ESX Server v2.5.11, 2, PCI−X HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
AX10011
109 IBM BladeCenter HS20 (Model: VMware ESX Server v2.5.11, 2, PCI−X IBM HS20 FC Exp Card (13N2203)12, 13 FC−SW EMC Y7, 25
8678)39, 8832)39, 8832−N1X); 3, 4, 5 CLARiiON
AX10011
IBM BladeCenter HS40 (Model 8839)
110 IBM BladeCenter HS20 (Model 8843) VMware ESX Server v2.5.11, 2, PCI−X IBM HS20 FC Exp Card (26K4841)12, 13, 22, 45 FC−SW EMC Y7, 25
3, 4, 5 CLARiiON
AX10011

111 IBM BladeCenter HS20 (Model: VMware ESX Server v2.5.11, 2, PCI−X IBM HS20 FC Exp Card (48P7061)12, 13, 22 FC−SW EMC Y7, 25
8678)39, 8832)39, 8832−N1X), 8843) 3, 4, 5 CLARiiON
AX10011
112 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server v2.5.11, 2, PCI−X QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
2650, 4600, 6600, 6650; 3, 4, 5 CLARiiON
AX10011
Fujitsu Siemens Primergy: RX300 S2,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL56040, DL74040,
DL760 (G2)40, DL76040, ML570(G2)40,
ML570(G3)40, 54;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)43, xSeries x440;
NEC Express 5800 120Lh;
Sun: V20z, V40z
113 HPQ Proliant BL20p (G2) VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL20p (G2) 300874−B2112, 19 CLARiiON
AX10011

114 HPQ Proliant BL20p (G3) VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL20p (G3) 361426−B2112, 19 CLARiiON
AX10011

115 HPQ Proliant BL25p VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
AX10011

116 HPQ Proliant BL35p VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL30p/BL35p 354054−B2112, 19 CLARiiON
AX10011
117 HPQ Proliant BL30p VMware ESX Server v2.5.11, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y7, 25
3, 4, 5 Proliant BL30p/BL35p 354054−B2119, 49 CLARiiON
AX10011
118 IBM xSeries x3950/x3950E/x460 (8872, VMware ESX Server v2.5.11, 2, PCI−X42 QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
8874)43, 54 3, 4, 5 CLARiiON
AX10011

119 HPQ Proliant: DL380(G2)40, VMware ESX Server v2.5.11, 2, PCI, QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
DL380(G4)40, 54, DL38040, DL38540, 3, 4, 5 PCI−X CLARiiON
DL580(G2)40, DL580(G3)40, 54, AX10011
DL58540, ML370(G3)40, ML370(G4)40,
54;

IBM: eServer 325 (Model 8835),


xSeries x345 (8670), xSeries x445
(8870)
120 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server v2.5.21, 2, PCI−X QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
2650, 4600, 6600, 6650; 3, 4, 5 CLARiiON
AX10011
Fujitsu Siemens Primergy: RX300,
RX300 S2, RX600 S2, TX300, TX300
S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL56040, DL74040,
DL760 (G2)40, DL76040, ML570(G2)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)43, xSeries x440;
NEC Express 5800 120Lh;
Sun: V20z, V40z

11/02/2006 189 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
121 Fujitsu Siemens Primergy: RX300, VMware ESX Server v2.5.21, 2, PCI−X QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
RX600 S2, TX300, TX600 S2; 3, 4, 5 CLARiiON
AX10011
HPQ Proliant ML570(G3)40
122 Fujitsu Siemens Primergy: RX600, VMware ESX Server v2.5.21, 2, PCI, QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
RX800, RX800 S2, TX600 3, 4, 5 PCI−X CLARiiON
AX10011

123 Fujitsu Siemens Primergy: RX600, VMware ESX Server v2.5.21, 2, PCI, QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
RX800, RX800 S2, TX600; 3, 4, 5 PCI−X CLARiiON
AX10011
HPQ Proliant: DL380(G2)40,
DL380(G4)40, DL38040, DL38540,
DL580(G2)40, DL580(G3)40, DL58540,
ML370(G3)40, ML370(G4)40;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
124 Dell PowerEdge 6850 VMware ESX Server v2.5.31, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5 Express CLARiiON
AX100
125 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server v2.5.31, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5 Express, CLARiiON
IBM xSeries x336 (8837)50 PCI−X AX100
126 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server v2.5.31, 2, PCI Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
3, 4, 5 Express, CLARiiON
IBM xSeries x336 (8837)50; PCI−X AX100
NEC Express 5800 110Rg−1
127 HPQ Proliant BL20p (G3) VMware ESX Server v2.5.31, 2, PCI−X18 HPQ Emulex−based BL20p (G3) Fibre Channel FC−SW EMC Y
3, 4, 5 Mezzanine HBA − 394757−B2110, 17 CLARiiON
AX10011
128 Dell PowerEdge: 1950, 6850 VMware ESX Server v2.5.41, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express CLARiiON
AX100
129 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, PCI Emulex: LP1050−E8, 10, 22, 31 , LP1050−E8, 10, 32, FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express LP982−E8, 10 CLARiiON
AX100
130 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
3, 4, 5, 14, 15, 16 Express CLARiiON
AX10011

131 Dell PowerEdge: 1950, 6850 VMware ESX Server v2.5.41, 2, PCI QLogic QLE2360−E−SP12, 22, 46 FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express CLARiiON
AX10011
132 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, PCI QLogic: QLA2340−E−SP12, 13, QLE2360−E−SP12, FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express 22, 29, 46 CLARiiON
AX10011
133 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, PCI Emulex LP1050−E8, 10, 22, 31 FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
134 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
2950, 6850; 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
IBM xSeries x336 (8837)50
135 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
2950, 6850; 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
IBM xSeries x336 (8837)50;
NEC Express 5800 110Rg−1
136 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
2950, 6850; 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
IBM xSeries: x336 (8837)50, x346
(8840)50
137 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011

138 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, PCI QLogic QLE2360−E−SP12, 22, 29, 46 FC−SW EMC Y
2950 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
139 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, PCI QLogic QLE2360−E−SP12, 22, 46 FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
140 HPQ Proliant BL20p: (G3), (G4) VMware ESX Server v2.5.41, 2, PCI−X18 HPQ: Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, 14, 15, 16 Proliant BL20p (G3) 361426−B2112, 19, CLARiiON
Emulex−based BL20p (G3) Fibre Channel AX10011
Mezzanine HBA − 394757−B2110, 17
141 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v2.5.41, 2, PCI, PCI Emulex: LP1050−E8, 10, 32, LP1050Ex−E8, 9, 10, 22 , FC−SW EMC N7
3, 4, 5, 14, 15, 16 Express, LP982−E8, 10 CLARiiON
PCI−X AX100
142 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v2.5.41, 2, PCI, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX10011
143 HPQ Proliant BL460c: (416653−B21), VMware ESX Server v3.0.11, 2, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−SW EMC N
(416654−B21), (416655−B21), 4, 16, 20 c−Class Bladesystem (403619−B21)57, 60 CLARiiON
(416656−B21), (432636−B21); AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)

11/02/2006 190 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
144 IBM BladeCenter HS20 (Model: VMware ESX Server v3.0.11, 2, PCI−X IBM Emulex LP1005DC FC Exp Card22, 24 FC−SW EMC Y7, 25
8832)39, 8832−N1X), 8843); 4, 16, 20 CLARiiON
AX100
IBM BladeCenter: HS40 (Model 8839),
LS20 (Model 8850)
145 IBM BladeCenter HS20 (Model: VMware ESX Server v3.0.11, 2, PCI−X IBM HS20 FC Exp Card (13N2203)13, 26 FC−SW EMC Y7, 25
8832)39, 8832−N1X); 4, 16, 20 CLARiiON
AX100
IBM BladeCenter HS40 (Model 8839)
146 IBM BladeCenter HS20 (Model 8843) VMware ESX Server v3.0.11, 2, PCI−X IBM HS20 FC Exp Card (26K4841)13, 22, 26, 45 FC−SW EMC Y7, 25
4, 16, 20 CLARiiON
AX100
147 IBM BladeCenter HS20 (Model: VMware ESX Server v3.0.11, 2, PCI−X IBM HS20 FC Exp Card (48P7061)22, 26 FC−SW EMC Y7, 25
8832)39, 8832−N1X), 8843) 4, 16, 20 CLARiiON
AX100
148 IBM BladeCenter LS20 (Model 8850) VMware ESX Server v3.0.11, 2, PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM eServer FC−SW EMC Y7, 25
4, 16, 20 LS2013, 22, 26, SFF Exp Card (26K4841) for IBM CLARiiON
eServer LS2022, 26 AX100
149 IBM BladeCenter HS21 (Model 8853)56 VMware ESX Server v3.0.11, 2, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y7, 25
4, 16, 20 (39Y9186)22, 24, HS20 4GB SFF FC Exp Card CLARiiON
(26R0890)22, 57, 59, HS20 FC Exp Card AX100
(13N2203)22, 57, 58, HS20 FC Exp Card
(48P7061)22, 57
150 HPQ Proliant BL460c: (416653−B21), VMware ESX Server v3.01, 2, 4, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−SW EMC N
(416654−B21), (416655−B21), 16, 20 c−Class Bladesystem (403619−B21)26, 60 CLARiiON
(416656−B21), (432636−B21); AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
151 Dell PowerEdge 6850 VMware ESX Server: v2.5.21, 2, PCI QLogic QLE2360−E−SP12, 22, 46 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Express CLARiiON
AX10011

152 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server: v2.5.21, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Express, CLARiiON
IBM xSeries: x336 (8837)50, x346 PCI−X AX10011
(8840)50
153 Dell PowerEdge: 1850, 2850 VMware ESX Server: v2.5.21, 2, PCI QLogic QLE2360−E−SP12, 22, 29, 46 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Express, CLARiiON
PCI−X AX10011
154 HPQ Proliant BL20p (G3) VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 Proliant BL20p (G3) 361426−B2112, 19 CLARiiON
AX10011
155 Fujitsu Siemens Primergy BX620: VMware ESX Server: v2.5.21, 2, PCI Fujitsu Siemens BX600−FC22Q12, 13, 22, 37 FC−SW EMC Y
S2F38, S238; 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
Fujitsu Siemens Primergy: BX62038,
BX630 (2−way)65, BX66038
156 Dell PowerEdge: 1550, 255044, 6450; VMware ESX Server: v2.5.21, 2, PCI QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
HPQ Proliant: DL360(G2)40, DL36040, 2, 3, 4, 5, 14, 15, 16 AX10011
DL380(G3)40, DL58040;
IBM xSeries: x330, x335;
NEC Express 5800 140Hd
157 Dell PowerEdge 6850 VMware ESX Server: v2.5.21, 2, PCI Dell 2362M12, 47, 48 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Express, CLARiiON
2, 3, 4, 5, 14, 15, 16 PCI−X AX10011

158 Dell PowerEdge 1855 VMware ESX Server: v2.5.21, 2, PCI−X Dell 2342M12, 13 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
159 HPQ Proliant BL45p VMware ESX Server: v2.5.21, 2, PCI−X HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
160 IBM BladeCenter HS20 (Model: VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC Exp Card (13N2203)12, 13 FC−SW EMC Y
8678)39, 8832)39, 8832−N1X); 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
IBM BladeCenter HS40 (Model 8839)
161 IBM BladeCenter HS20 (Model 8843) VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC Exp Card (26K4841)12, 13, 22, 45 FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
162 IBM BladeCenter HS20 (Model: VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC Exp Card (48P7061)12, 13, 22 FC−SW EMC Y
8678)39, 8832)39, 8832−N1X), 8843) 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
163 IBM BladeCenter LS20 (Model 8850) VMware ESX Server: v2.5.21, 2, PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM eServer FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, LS2012, 13, 22, SFF Exp Card (26K4841) for IBM CLARiiON
2, 3, 4, 5, 14, 15, 16 eServer LS2012, 13, 22 AX10011
164 HPQ Proliant BL20p (G2) VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL20p (G2) 300874−B2112, 19 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011

165 HPQ Proliant BL25p VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL25p/BL45p 381881−B2112, 51 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
166 HPQ Proliant BL35p VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL30p/BL35p 354054−B2112, 19 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011

11/02/2006 191 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
167 HPQ Proliant BL30p VMware ESX Server: v2.5.21, 2, PCI−X18 HPQ Dual−port Fibre Channel Adapter for HP FC−SW EMC Y
3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, Proliant BL30p/BL35p 354054−B2119, 49 CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
168 IBM xSeries x3950/x3950E/x460 (8872, VMware ESX Server: v2.5.21, 2, PCI−X42 QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
8874)43 3, 4, 5, v2.5.31, 2, 3, 4, 5 , v2.5.41, CLARiiON
2, 3, 4, 5, 14, 15, 16 AX10011
169 Dell PowerEdge: 1550, 255044, 645052; VMware ESX Server: v2.5.31, 2, PCI Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
HPQ Proliant: DL360(G2)40, DL36040, AX100
DL380(G3)40, DL58040;
IBM xSeries: x330, x335;
NEC Express 5800: 120Rf−2, 140Hd,
140Rc−4, 180Rc−4, 180Rd−4
170 NEC Express 5800: 120Rf−2, 140Hd, VMware ESX Server: v2.5.31, 2, PCI NEC N8190−120 (LP1050)6, 8, 9, 10 FC−SW EMC N7
140Rc−4, 180Rd−4 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX100
171 NEC Express 5800 110Rg−1 VMware ESX Server: v2.5.31, 2, PCI NEC N8190−120 (LP1050)6, 8, 9, 10 FC−SW EMC N7
3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 Express, CLARiiON
PCI−X AX100
172 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server: v2.5.31, 2, PCI−X Emulex LP1050−E8, 10, 22, 31 FC−SW EMC N7
3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX100
173 HPQ Proliant DL360(G4)40 VMware ESX Server: v2.5.31, 2, PCI−X Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX100
174 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server: v2.5.31, 2, PCI−X Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
2650, 4600, 6600, 6650; 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX100
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL56040, DL74040,
DL760 (G2)40, DL76040, ML570(G2)40,
ML570(G3)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)43, xSeries x440;
NEC Express 5800: 120Lh, 120Re−1,
120Rf−1, 120Rg−2, 120Rh−2, 420Ma;
Sun: V20z, V40z
175 NEC Express 5800: 120Lh, 120Re−1, VMware ESX Server: v2.5.31, 2, PCI−X NEC N8190−120 (LP1050)6, 8, 9, 10 FC−SW EMC N7
120Rf−1, 120Rg−2, 120Rh−2, 140He, 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
140Rd−4 AX100
176 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server: v2.5.31, 2, PCI−X QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
2650, 4600, 6600, 6650; 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX10011
Fujitsu Siemens Primergy: RX300 S2,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)40,
DL360(G4)40, DL56040, DL74040,
DL760 (G2)40, DL76040, ML570(G2)40;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)43, xSeries x440;
NEC Express 5800 120Lh;
Sun: V20z, V40z
177 HPQ Proliant ML570(G3)40 VMware ESX Server: v2.5.31, 2, PCI−X QLogic QLA2340−E−SP12, 13 FC−SW EMC Y7, 25
3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX10011
178 IBM xSeries x3950/x3950E/x460 (8872, VMware ESX Server: v2.5.31, 2, PCI−X42 Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
8874)43 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 CLARiiON
AX100
179 HPQ Proliant: DL380(G4)40, VMware ESX Server: v2.5.31, 2, PCI, Emulex LP1050Ex−E8, 9, 10, 22 FC−SW EMC N7
DL580(G3)40 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 PCI−X CLARiiON
AX100
180 HPQ Proliant: DL380(G2)40, VMware ESX Server: v2.5.31, 2, PCI, Emulex: LP1050−E8, 10, 32, LP982−E8, 10 FC−SW EMC N7
DL380(G4)40, DL38040, DL38540, 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 PCI−X CLARiiON
DL580(G2)40, DL580(G3)40, DL58540, AX100
ML370(G3)40, ML370(G4)40;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
181 HPQ Proliant: DL380(G2)40, VMware ESX Server: v2.5.31, 2, PCI, QLogic QLA2340−E−SP12, 13 FC−SW EMC Y
DL380(G4)40, DL38040, DL38540, 3, 4, 5, v2.5.41, 2, 3, 4, 5, 14, 15, 16 PCI−X CLARiiON
DL580(G2)40, DL580(G3)40, DL58540, AX10011
ML370(G3)40, ML370(G4)40;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
182 HPQ Proliant BL460c: (416653−B21), VMware ESX Server: v3.0.11, 2, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−SW EMC Y61, 62
(416654−B21), (416655−B21), 4, 16, 20, v3.01, 2, 4, 16, 20 c−Class Bladesystem (403621−B21)24, 63, 64 CLARiiON
(416656−B21), (432636−B21); AX100
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)

11/02/2006 192 CLARiiON AX100


CLARiiON AX100

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
183 IBM BladeCenter HS20 (Model: VMware ESX Server: v3.02, 4, 16, PCI−X IBM Emulex LP1005DC FC Exp Card22, 28 FC−SW EMC Y7, 25
8832)39, 8832−N1X), 8843); 20, 21, v3.02, 4, 20, 21 CLARiiON
AX100
IBM BladeCenter: HS40 (Model 8839),
LS20 (Model 8850)
184 IBM BladeCenter HS20 (Model: VMware ESX Server: v3.02, 4, 16, PCI−X IBM HS20 FC Exp Card (13N2203)12, 13 FC−SW EMC Y7, 25
8832)39, 8832−N1X); 20, 21, v3.02, 4, 20, 21 CLARiiON
AX100
IBM BladeCenter HS40 (Model 8839)
185 IBM BladeCenter HS20 (Model 8843) VMware ESX Server: v3.02, 4, 16, PCI−X IBM HS20 FC Exp Card (26K4841)12, 13, 22, 45 FC−SW EMC Y7, 25
20, 21, v3.02, 4, 20, 21 CLARiiON
AX100
186 IBM BladeCenter HS20 (Model: VMware ESX Server: v3.02, 4, 16, PCI−X IBM HS20 FC Exp Card (48P7061)12, 22 FC−SW EMC Y7, 25
8832)39, 8832−N1X), 8843) 20, 21, v3.02, 4, 20, 21 CLARiiON
AX100
187 IBM BladeCenter LS20 (Model 8850) VMware ESX Server: v3.02, 4, 16, PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM eServer FC−SW EMC Y7, 25
20, 21, v3.02, 4, 20, 21 LS2012, 13, 22, SFF Exp Card (26K4841) for IBM CLARiiON
eServer LS2012, 22 AX100
1. Beginning with ESX Server v2.5.0 Navisphere components are supported as follows:
Navi Agent and Server Utility at the console level only;
Array Initialization Utility and CLI at both the console and VM levels;
Browser interface to Navisphere Express or Navi Manager at the VM level only.
2. Supported with VirtualCenter VMotion.
3. Supported with VMFS and VMFS−2.
4. PowerPath is not supported on VMWare ESX. The VMWare ESX native failover functionality is supported.
5. While using an AX100−series storage system managed using Navisphere Express with VMware ESX Server, Snapshots cannot be assigned to the ESX server.
6. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
7. Virtual machines running on VMWare ESX are supported booting from the array.
8. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
9. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. Driver Version 2.01g This driver is included in the VMware ESX kernel.
11. CLARiiON AX100 is supported with VMware ESX Server starting with FLARE R19.
12. Driver Version 7.04.00 This driver is included in the VMware ESX kernel.
13. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Replicas of application data volumes of physical (native) servers created using SnapView, MirrorView and SAN Copy can be presented to a VMware ESX Server. These replicas
configured on the VMware ESX server must be Raw Device Mapping only (VMFS is not supported). Replicas of application data volumes configured as Raw Device Mapping volumes
on a VMware ESX server can also be presented to a physical (native) server.
Replication of Operating System volumes and application volumes from a physical to virtual or virtual to physical environment using CLARiiON replication software is not supported at
this time. Replication of Operating System volumes, application volumes and application data volumes from a virtual to virtual environment using CLARiiON replication software is
supported.
15. Replication of both VMFS and Raw Device Mapping (RDM) volumes is supported using CLARiiON replication software (SnapView, MirrorView and SAN Copy) starting with Release 19.
The OS/application as well as application data can be replicated using CLARiiON replication software.
Note:
1) The virtual disks in a VMFS volume must be in persistent−mode during the replication process.
2) CLARiiON VSS provider is not supported on VMFS volumes.
3) If replicating an entire VMFS volume that contains a number of virtual disks on a single CLARiiON LUN, the granularity of replication is the entire LUN with all its virtual disks.
4) Use the consistency technology available on SnapView/MirrorView, when making copies of VMFS volumes that span multiple CLARiiON LUNs.
5) The VMFS replica must be assigned to a different ESX server. The target ESX server must not already have access to the original source VMFS volume.
6) For source LUNs configured as RDM volumes, the replica can be presented to the same ESX server but to a different Virtual Machine unless the guest OS is qualified to allow same
host access.
7) RDM volumes cannot be created when the ESX server is booting from SAN. VMFS volumes can be created when the ESX server is booting from SAN. If ESX server is not booting
from SAN, Virtual Machines can be configured using either VMFS or RDM volumes.
8) Ensure the snapshot is activated or clone fractured before presenting them to an ESX server.
9) When replicating OS images, you will only have a crash consistent copy if the Virtual Machines are not shutdown during the replication process.
10) Please note that replicating a suspended Virtual Machine will result in a crash consistent copy.
11) Admsnap, Admhost utilities must be installed only on Virtual Machines. With admsnap or admhost installed on the Virtual Machine, most of the commands issued on VMFS volumes
will fail, since VMFS volumes do not support scsi pass−through commands to talk to the CLARiiON. Use Navisphere Manager or Navisphere CLI instead. The only commands that will
work with VMFS volumes are admsnap flush and admhost flush. Admsnap is not supported under Netware Virtual Machines with either RDM or VMFS volumes.
16. Replication of both VMFS and Raw Device Mapping (RDM) volumes is supported using Symmetrix replication software (SRDF and TimeFinder). Please refer to the solution guide,
'VMware ESX Server Using EMC Symmetrix Storage Systems' for details.
Replicas of application data volumes of physical (native) servers created using Symmetrix replication software can be presented to a VMware ESX Server. Note:
1) Replication of Operating System volumes and application volumes from a virtual to physical environment using Symmetrix replication software is not supported at this time.
2) Replication of Operating System volumes, application volumes and application data volumes from a virtual to virtual environment using Symmetrix replication software is supported.
17. BIOS 1.70a3
18. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
19. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Supported with VMFS−3.
21. Beginning with ESX Server v2.5.0 Navisphere components are supported as follows:
Navi Agent and Server Utility at the console level only;
Array Initialization Utility and CLI at both the console and VM levels;
Browser interface to Navi Manager at the VM level only.
22. SNIA HBA API Supported.
23. Firmware Version 2.50a6
24. Driver Version 7.3.2 This driver is included in the VMware ESX kernel.
25. VMWare ESX Server itself is supported booting from external array.
26. Driver Version 7.07.00 This driver is included in the VMware ESX kernel.
27. BIOS 1.08
28. Driver Version 7.1.14 This driver is included in the VMware ESX kernel.
29. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
30. FCode Value 1.70a3
31. Firmware Version 1.91a1
32. Firmware Version 1.91a5
33. Requires BIOS 1.47 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
34. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. BIOS 1.70a3 This driver is included in the VMware ESX kernel. Available in the EMC−approved section of the Emulex website. http://www.emulex.com
36. This HBA is equivalent to the QLogic QLA2340.
37. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
38. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
39. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
40. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
41. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. Accepts PCI−X 1.0 and 2.0 HBAs.
43. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
44. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
45. Firmware Version 3.01.18
46. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
47. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
48. BIOS 1.06 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
49. Driver Version 7.04.00 Requires BIOS 1.45 (HP BL30p specific) available from QLogic at http://www.qlogic.com This driver is included in the VMware ESX kernel.
50. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.

11/02/2006 193 CLARiiON AX100


CLARiiON AX100

51. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
52. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
53. BIOS 1.17
54. Single core processors only.
55. This driver is included in the VMware ESX kernel.
56. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
57. Driver Version 7.07.04 This driver is included in the VMware ESX kernel.
58. BIOS 1.47
59. BIOS 1.12
60. BIOS 1.16
61. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
62. VxVM is not supported on servers booting from the array.
63. BIOS 6.00a1
64. Firmware Version 2.50a8
65. Only supported in a boot from SAN configuration.

Cluster Software
Microsoft Windows 2000
EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Microsoft Windows 2000


Cluster Max #
No. Operating System Software Nodes Infrastructure Software Server LVM Storage Array Comments
1 Microsoft Windows 2000: Advanced Microsoft HA: 2 EMC PowerPath: 4.3.1, Veritas VxVM: 4.0, 4.1, 4.2 (Storage EMC See3
Server SP4, Server SP4 MSCS1, 2 4.4.1, 4.5.0, 4.5.1 Foundation), 4.3 (Storage Foundation) CLARiiON
AX100
1. Cluster software is not supported on Stratus ftServers.
2. Valid MSCS quorum resource configurations include both 'shared disk quorum' and 'majority node set' schemes.
3. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

Microsoft Windows 2003 [x64]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Microsoft Windows 2003 [x64]


Cluster Max # Infrastructure Storage
No. Operating System Software Nodes Software Server LVM Array Comments
1 Microsoft Windows 2003 [x64]: DataCenter, DataCenter R2, Microsoft HA: 8 EMC PowerPath: Veritas VxVM: 4.0, 4.1, 4.2 EMC See2
Enterprise Edition, Enterprise Edition R2, Storage Server MSCS1 4.4.1, 4.5.0, 4.5.1, (Storage Foundation), 4.3 (Storage CLARiiON
Enterprise Edition R2 4.6.0, 4.6.1 Foundation) AX100
1. Valid MSCS quorum resource configurations include both 'shared disk quorum' and 'majority node set' schemes.
2. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

Microsoft Windows 2003 [x86]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Microsoft Windows 2003 [x86]


Cluster Max # Infrastructure Storage
No. Operating System Software Nodes Software Server LVM Array Comments
1 Microsoft Windows 2003 [x86]: DataCenter, DataCenter R2, DataCenter SP1, Microsoft HA: 8 EMC PowerPath: Veritas VxVM: 4.0, EMC See3
Enterprise Edition, Enterprise Edition R2, Enterprise Edition SP1, Storage Server, MSCS1, 2 4.3.1, 4.4.1, 4.1, 4.2 (Storage CLARiiON
Storage Server Enterprise Edition, Storage Server Enterprise Edition R2, Storage 4.5.0, 4.5.1, Foundation), 4.3 AX100
Server Enterprise Edition SP1, Storage Server R2, Storage Server SP1 4.6.0, 4.6.1 (Storage Foundation)
1. Cluster software is not supported on Stratus ftServers.
2. Valid MSCS quorum resource configurations include both 'shared disk quorum' and 'majority node set' schemes.
3. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

Red Hat RHEL [32−Bit]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Red Hat RHEL [32−Bit]


Cluster Max # Infrastructure Server Storage
No. Operating System Software Nodes Software LVM Array
1 Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES v2.4.21−15.0.2.EL, U2+ AS/ES Oracle 10g RAC RAC: 8 EMC Oracle EMC
v2.4.21−15.0.3.EL, U2+ AS/ES v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES v2.4.21−27.EL, Release 11, 2, 3, PowerPath ASM CLARiiON
U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL, U5 AS/ES v2.4.21−32.EL, U5+ AS/ES 4, 5, 6, 7, 8 4.3.3 b010 10g AX100
v2.4.21−32.0.1.EL Release
19
2 Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U3 AS/ES v2.4.21−20.EL, U4+ AS/ES NEC ClusterPro EMC EMC
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U5 AS/ES v2.4.21−32.EL, U5+ AS/ES SE 3, Express PowerPath CLARiiON
v2.4.21−32.0.1.EL Cluster 3 4.3.3 b010 AX100

11/02/2006 194 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Cluster Max # Infrastructure Server Storage
No. Operating System Software Nodes Software LVM Array
3 Red Hat RHEL [32−Bit] 3.0: U3 AS/ES v2.4.21−20.EL, U4 AS/ES v2.4.21−27.EL, U4+ AS/ES Oracle 10g RAC RAC: 8 EMC Oracle EMC
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL Release 11, 2, 3, PowerPath ASM CLARiiON
4, 5, 6, 7, 8 4.3.2 b011 10g AX100
Release
19
4 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Oracle 10g RAC RAC: 8 EMC Oracle EMC
Release 11, 2, 3, PowerPath ASM CLARiiON
4, 5, 6, 7, 8 4.3.4 10g AX100
Release
19
5 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 AS/ES NEC ClusterPro EMC EMC
v2.4.21−40.EL SE 3, Express PowerPath CLARiiON
Cluster 3 4.3.4 AX100
6 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES NEC ClusterPro EMC EMC
v2.6.9−34.0.2.EL SE 3, Express PowerPath CLARiiON
Cluster 3 4.5.1 AX100
1. For supported (non−clustered) Oracle solutions, please visit the following url: http://www.emc.com/partnersalliances/partner_pages/oracle.jsp
2. Supported with Oracle 10g Release 10.1.0.2 or higher
3. Review Oracle Note 294430.1 for misscount setting change (value needs to be set to 120)
4. Oracle Patch 3626461 is required for 10g RAC (10.1.0.3)
5. OCFS requires additional metadata space (~11MB) for each host it is mounted on for the first time. Users mounting storage replicas on backup servers may observe a discrepancy in
used/available space in the OCFS. As a workaround, mount the primary OCFS devices on backup host at least once to register its metadata.
6. QLA200−E−SP is not supported in a direct attached active/active cluster configuration
7. OCFS 1.x is supported (see Oracle.com for kernel specific versions)
8. OCFS and OCFS2 do not immediately update mtime (modified time) for Oracle data and log files on OCFS volumes. OCFS remounted from storage replicas of a mounted production
OCFS may show different mtime for some OCFS files. This has no bearing on correctness of the content of these OCFS files as replicated.
9. ASM must utilize raw devices bound to emcpower devices

Red Hat RHEL [EM64T]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Red Hat RHEL [EM64T]


Infrastructure Storage
No. Operating System Cluster Software Software Array
1 Red Hat RHEL [EM64T] 3.0: U4 AS/ES v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES NEC ClusterPro SE 3, EMC PowerPath EMC
v2.4.21−27.0.2.EL, U5 AS/ES v2.4.21−32.EL, U5+ AS/ES v2.4.21−32.0.1.EL Express Cluster 3 4.3.3 b010 CLARiiON
AX100
2 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 AS/ES NEC ClusterPro SE 3, EMC PowerPath EMC
v2.4.21−40.EL Express Cluster 3 4.3.4 CLARiiON
AX100
3 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES NEC ClusterPro SE 3, EMC PowerPath EMC
v2.6.9−34.0.2.EL Express Cluster 3 4.5.1 CLARiiON
AX100

Red Hat RHEL [IA64]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Red Hat RHEL [IA64]


Infrastructure
No. Operating System Cluster Software Software Storage Array
1 Red Hat RHEL [IA64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ NEC ClusterPro SE 3, Express EMC PowerPath EMC CLARiiON
AS/ES v2.6.9−34.0.2.EL Cluster 3 4.5.1 AX100

Fibre Connectivity: Switch


Haansoft Asianux Server 2.0 [32−Bit]
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Haansoft Asianux Server 2.0 [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Asianux Server 2.0 Dell 2342M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 15 15 256 256 Y EMC
[32−Bit] GA v2.6.9−11.19AX 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

11/02/2006 195 CLARiiON AX100


CLARiiON AX100

Haansoft Asianux Server 2.0 [AMD64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Haansoft Asianux Server 2.0 [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Asianux Server 2.0 Dell 2342M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 15 15 256 256 Y EMC
[AMD64] GA v2.6.9−11.19AX 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Haansoft Asianux Server 2.0 [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Haansoft Asianux Server 2.0 [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Asianux Server 2.0 Dell 2342M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 15 15 256 256 Y EMC
[EM64T] GA v2.6.9−11.19AX 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Haansoft Linux 2005 Server Asianux Inside [32−Bit]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Haansoft Linux 2005 Server Asianux Inside [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Linux 2005 Server Asianux Dell 2342M Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
Inside [32−Bit] v2.4.21−37.18AX (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Haansoft Linux 2005 Server Asianux Inside [AMD64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

11/02/2006 196 CLARiiON AX100


CLARiiON AX100

Haansoft Linux 2005 Server Asianux Inside [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Linux 2005 Server Asianux Dell 2342M Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
Inside [AMD64] v2.4.21−37.18AX (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Haansoft Linux 2005 Server Asianux Inside [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Haansoft Linux 2005 Server Asianux Inside [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Linux 2005 Server Asianux Dell 2342M Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
Inside [EM64T] v2.4.21−37.18AX (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Microsoft Windows 2000


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Microsoft Windows 2000


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Microsoft Windows 2000 Dell 2362M EMC Connectrix: DS−4400M, 15 15 256 128, 256 Y EMC
Advanced Server: SP4, SP41; DS−4700M; CLARiiON
AX100
Microsoft Windows 2000 McDATA: ES−4400, ES−4700
Server SP4
2 Microsoft Windows 2000 Emulex LP1050Ex−E EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Advanced Server: SP4, SP41; DS−4700M; CLARiiON
AX100
Microsoft Windows 2000 McDATA: ES−4400, ES−4700
Server SP4
3 Microsoft Windows 2000 Emulex: LPe111−E, LPe1150−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Advanced Server: SP4, SP41; DS−4700M; CLARiiON
HPQ: A7560A (LP1050Ex), AX100
Microsoft Windows 2000 A8002A/FC2142SR (LPe1150); McDATA: ES−4400, ES−4700
Server SP4
NEC: N8190−127 (LPe1150),
N8803−031 (QLA2310F);
QLogic QLE220−E−SP
4 Microsoft Windows 2000 Emulex: LP1050−E, LP982−E; EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Advanced Server: SP4, SP41; DS−4700M; CLARiiON
HPQ: A7298A (LP982), A7388A AX100
Microsoft Windows 2000: (LP1050), FCA2214 (QLA2340), McDATA: ES−4400, ES−4700
Datacenter SP4, Server SP4 FCA2408 (LP982);
QLogic: QLA2310F−E−SP,
QLA2340−E−SP;
Unisys FCH752313−PCX (LP1050)
5 Microsoft Windows 2000 Emulex: LP1150−E, LP982−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Advanced Server: SP4, SP41; DS−4700M; CLARiiON
IBM 39M5894 (QLA2460); AX100
Microsoft Windows 2000: QLogic: QLA2310F−E−SP, McDATA: ES−4400, ES−4700
Datacenter SP4, Server SP4 QLA2340−E−SP, QLA2460−E−SP,
QLE2460−E−SP, QLE2462−E−SP

11/02/2006 197 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2000


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
6 Microsoft Windows 2000 NEC N8190−120 (LP1050); EMC Connectrix: DS−4400M, 15 15 256 128, 256 Y EMC
Advanced Server: SP4, SP41; QLogic QLE2360−E−SP DS−4700M; CLARiiON
AX100
Microsoft Windows 2000: McDATA: ES−4400, ES−4700
Datacenter SP4, Server SP4
7 Microsoft Windows 2000 IBM 19K1246 (QLA2310) EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Datacenter SP4 DS−4700M; CLARiiON
AX100
McDATA: ES−4400, ES−4700
8 Microsoft Windows 2000: Emulex LP1050−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Advanced Server SP4, HPQ: A7298A (LP982), A7388A DS−4700M; CLARiiON
Datacenter SP4, Server SP4 (LP1050), FCA2214 (QLA2340), AX100
FCA2408 (LP982); McDATA: ES−4400, ES−4700
IBM 24P0960 (QLA2340)
9 Microsoft Windows 2000: Dell 2342M Dell: Brocade 1/2Gb FC Switch 15 15 256 256 Y EMC
Advanced Server SP4, Server Module (SW3014), McDATA FC CLARiiON
SP4 Switch Module (SW4314) AX100
10 Microsoft Windows 2000: Dell: 2342M, LPe1105−M, QME2462 Dell: Brocade 4Gb FC Switch 15 15 256 256 Y EMC
Advanced Server SP4, Server Module (SW4016), McDATA FC CLARiiON
SP4 Switch Module (SW4416) AX100
11 Microsoft Windows 2000: Emulex: LP101−E, LP982−E; Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
Advanced Server SP4, Server CLARiiON
SP4 QLogic: QLA200−E−SP, EMC Connectrix: 3250−VL2E2, AX100
QLA210−E−SP, QLA2340−E−SP DS−220B−FF−D4, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
12 Microsoft Windows 2000: IBM 39M5894 (QLA2460); Brocade Silkworm: 205E, 207E; 15 15 256 256 Y EMC
Advanced Server SP4, Server QLogic: QLA2460−E−SP, CLARiiON
SP4 QLE220−E−SP, QLE2460−E−SP, EMC Connectrix: 3250−VL2E2, AX100
QLE2462−E−SP DS−220B−FF−D4, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
13 Microsoft Windows 2000: QLogic QLE2360−E−SP Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
Advanced Server SP4, Server CLARiiON
SP4 EMC Connectrix: 3250−VL2E2, AX100
DS−220B−FF−D4, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
1. Windows 2000 hosts running less than SP4 could be susceptible to data loss during LUN expansion operations. This issue is corrected by Microsoft in SP4, or by applying hotfix 327020.
See EMC Solution IS emc73538 and Microsoft Knowledge Base article 327020 for more information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
4. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Microsoft Windows 2003 [x64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Microsoft Windows 2003 [x64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Microsoft Windows 2003 Dell 2342M Dell: Brocade 1/2Gb FC Switch 15 15 256 256 Y EMC
[x64] Enterprise: Edition, Module (SW3014), McDATA CLARiiON
Edition R2; FC Switch Module (SW4314) AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R2
2 Microsoft Windows 2003 Dell 2362M; EMC Connectrix: DS−4400M, 15 15 256 128, 256 Y EMC
[x64] Enterprise: Edition, NEC N8190−120 (LP1050); DS−4700M; CLARiiON
Edition R2; QLogic QLE2360−E−SP AX100
McDATA: ES−4400, ES−4700
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R2
3 Microsoft Windows 2003 Dell: 2342M, LPe1105−M, QME2462 Dell: Brocade 4Gb FC Switch 15 15 256 256 Y EMC
[x64] Enterprise: Edition, Module (SW4016), McDATA CLARiiON
Edition R2; FC Switch Module (SW4416) AX100
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R2

11/02/2006 198 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
4 Microsoft Windows 2003 Emulex LP1150−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
[x64] Enterprise: Edition, HPQ: A7298A (LP982), A7388A (LP1050), DS−4700M; CLARiiON
Edition R2; A7560A (LP1050Ex), A8002A/FC2142SR AX100
(LPe1150), FCA2214 (QLA2340), FCA2408 McDATA: ES−4400, ES−4700
Microsoft Windows 2003 (LP982);
[x64] Standard: Edition,
Edition R2 IBM: 19K1246 (QLA2310), 24P0960
(QLA2340), 39M5894 (QLA2460);
NEC: N8190−127 (LPe1150), N8803−031
(QLA2310F);
QLogic QLA2460−E−SP
5 Microsoft Windows 2003 Emulex LP982−E; Brocade Silkworm: 205E, 15 15 256 128 Y EMC
[x64] Enterprise: Edition, QLogic QLA2340−E−SP 207E; CLARiiON
Edition R2; AX100
EMC Connectrix: 3250−VL2E3,
Microsoft Windows 2003 DS−220B−FF−D1,
[x64] Standard: Edition, DS−8B2−0DL;
Edition R2
McDATA ES−43002;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
6 Microsoft Windows 2003 Emulex: LP1050−E, LP1050Ex−E, LP982−E; EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
[x64] Enterprise: Edition, DS−4700M; CLARiiON
Edition R2; HPQ: A7298A (LP982), A7388A (LP1050), AX100
FCA2214 (QLA2340), FCA2408 (LP982); McDATA: ES−4400, ES−4700
Microsoft Windows 2003
[x64] Standard: Edition, QLogic: QLA2310F−E−SP, QLA2340−E−SP;
Edition R2
Unisys FCH752313−PCX (LP1050)
7 Microsoft Windows 2003 HPQ: A7298A (LP982), A7388A (LP1050), Brocade Silkworm: 205E, 15 15 256 223, 256 Y EMC
[x64] Enterprise: Edition, FCA2214 (QLA2340), FCA2408 (LP982) 207E; CLARiiON
Edition R2; AX100
EMC Connectrix
Microsoft Windows 2003 DS−220B−FF−D1;
[x64] Standard: Edition, McDATA ES−43002
Edition R2
8 Microsoft Windows 2003 HPQ: A7298A (LP982), A7388A (LP1050), Brocade Silkworm: 205E, 15 15 256 256 Y EMC
[x64] Enterprise: Edition, FCA2214 (QLA2340), FCA2408 (LP982); 207E; CLARiiON
Edition R2; AX100
IBM: 24P0960 (QLA2340), 39M5894 EMC Connectrix
Microsoft Windows 2003 (QLA2460); DS−220B−FF−D1;
[x64] Standard: Edition, McDATA ES−43002
Edition R2 QLogic QLA2460−E−SP
9 Microsoft Windows 2003 IBM 39M5894 (QLA2460); EMC Connectrix: 3250−VL2E3, 15 15 256 256 Y EMC
[x64] Enterprise: Edition, QLogic QLA2460−E−SP DS−8B2−0DL; CLARiiON
Edition R2; AX100
QLogic SANBox:
Microsoft Windows 2003 SB1404−10AJ−E,
[x64] Standard: Edition, SB3050−08A−E
Edition R2
10 Microsoft Windows 2003 NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
[x64] Enterprise: Edition, QLogic QLE2360−E−SP 207E; CLARiiON
Edition R2; AX100
EMC Connectrix
Microsoft Windows 2003 DS−220B−FF−D1;
[x64] Standard: Edition, McDATA ES−43002
Edition R2
11 Microsoft Windows 2003 QLogic QLE2360−E−SP EMC Connectrix: 3250−VL2E3, 15 15 256 128, 256 Y EMC
[x64] Enterprise: Edition, DS−8B2−0DL; CLARiiON
Edition R2; AX100
QLogic SANBox:
Microsoft Windows 2003 SB1404−10AJ−E,
[x64] Standard: Edition, SB3050−08A−E
Edition R2
12 Microsoft Windows 2003 Emulex: LP1050−E, LP982−E, LPe111−E, EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
[x64] Enterprise: Edition, LPe1150−E; DS−4700M; CLARiiON
Edition R2; AX100
QLogic: QLA2310F−E−SP, QLA2340−E−SP, McDATA: ES−4400, ES−4700
Microsoft Windows 2003 QLE220−E−SP
[x64] Standard: Edition,
Edition R2;
Microsoft Windows 2003
[x64] Storage Server:
Enterprise Edition R2,
Standard Edition R2
13 Microsoft Windows 2003 QLogic QLE220−E−SP Brocade Silkworm: 205E, 15 15 256 256 Y EMC
[x64] Enterprise: Edition, 207E; CLARiiON
Edition R2; AX100
EMC Connectrix: 3250−VL2E3,
Microsoft Windows 2003 DS−220B−FF−D1,
[x64] Standard: Edition, DS−8B2−0DL;
Edition R2;
McDATA ES−43002;
Microsoft Windows 2003 QLogic SANBox:
[x64] Storage Server: SB1404−10AJ−E,
Enterprise Edition R2, SB3050−08A−E
Standard Edition R2

11/02/2006 199 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
14 Microsoft Windows 2003 QLogic: QLE2460−E−SP, QLE2462−E−SP Brocade Silkworm: 205E, 15 15 256 256 Y EMC
[x64] Enterprise: Edition, 207E; CLARiiON
Edition R2; AX100
EMC Connectrix: 3250−VL2E3,
Microsoft Windows 2003 DS−220B−FF−D1, DS−4400M,
[x64] Standard: Edition, DS−4700M, DS−8B2−0DL;
Edition R2;
McDATA: ES−43002,
Microsoft Windows 2003 ES−4400, ES−4700;
[x64] Storage Server:
Enterprise Edition R2, QLogic SANBox:
Standard Edition R2; SB1404−10AJ−E,
SB3050−08A−E
Microsoft Windows 2003
[x64] Unified Data Storage
Server
15 Microsoft Windows 2003 Emulex LP1050Ex−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
[x64] Storage Server: QLogic QLE2360−E−SP DS−4700M; CLARiiON
Enterprise Edition R2, AX100
Standard Edition R2 McDATA: ES−4400, ES−4700
16 Microsoft Windows 2003 Emulex: LP1050−E, LP1050Ex−E, LP982−E, Brocade Silkworm: 205E, 15 15 256 256 Y EMC
[x64] Storage Server: LPe111−E, LPe1150−E; 207E; CLARiiON
Enterprise Edition R2, AX100
Standard Edition R2 QLogic: QLA2340−E−SP, QLE2360−E−SP EMC Connectrix: 3250−VL2E3,
DS−220B−FF−D1,
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Microsoft Windows 2003 [x86]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Microsoft Windows 2003 [x86]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Microsoft Windows 2003 [x86] Enterprise: Edition, Dell 2342M Dell: Brocade 1/2Gb FC 15 15 256 256 Y EMC
Edition R2, Edition SP1; Switch Module CLARiiON
(SW3014), McDATA FC AX100
Microsoft Windows 2003 [x86] Standard: Edition, Switch Module
Edition R2, Edition SP1 (SW4314)
2 Microsoft Windows 2003 [x86] Enterprise: Edition, Dell 2362M EMC Connectrix: 15 15 256 128, 256 Y EMC
Edition R2, Edition SP1; DS−4400M, DS−4700M; CLARiiON
AX100
Microsoft Windows 2003 [x86] Standard: Edition, McDATA: ES−4400,
Edition R2, Edition SP1 ES−4700
3 Microsoft Windows 2003 [x86] Enterprise: Edition, Dell: 2342M, LPe1105−M, Dell: Brocade 4Gb FC 15 15 256 256 Y EMC
Edition R2, Edition SP1; QME2462 Switch Module CLARiiON
(SW4016), McDATA FC AX100
Microsoft Windows 2003 [x86] Standard: Edition, Switch Module
Edition R2, Edition SP1 (SW4416)
4 Microsoft Windows 2003 [x86] Enterprise: Edition, Emulex LP1050Ex−E; EMC Connectrix: 15 15 256 223, 256 Y EMC
Edition R2, Edition SP1; HPQ: A7298A (LP982), DS−4400M, DS−4700M; CLARiiON
FCA2214 (QLA2340), AX100
Microsoft Windows 2003 [x86] Standard: Edition, FCA2408 (LP982) McDATA: ES−4400,
Edition R2, Edition SP1 ES−4700
5 Microsoft Windows 2003 [x86] Enterprise: Edition, Emulex: LP101−E, Brocade Silkworm: 205E, 15 15 256 128 Y EMC
Edition R2, Edition SP1; LP982−E; 207E; CLARiiON
AX100
Microsoft Windows 2003 [x86] Standard: Edition, QLogic: QLA200−E−SP, EMC Connectrix:
Edition R2, Edition SP1 QLA210−E−SP, 3250−VL2E3,
QLA2340−E−SP DS−220B−FF−D2,
DS−8B2−0DL;
McDATA ES−43001;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
6 Microsoft Windows 2003 [x86] Enterprise: Edition, HPQ: A7298A (LP982), Brocade Silkworm: 205E, 15 15 256 223, 256 Y EMC
Edition R2, Edition SP1; A7388A (LP1050), 207E; CLARiiON
FCA2214 (QLA2340), AX100
Microsoft Windows 2003 [x86] Standard: Edition, FCA2408 (LP982) EMC Connectrix
Edition R2, Edition SP1 DS−220B−FF−D2;
McDATA ES−43001

11/02/2006 200 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
7 Microsoft Windows 2003 [x86] Enterprise: Edition, HPQ: A7298A (LP982), Brocade Silkworm: 205E, 15 15 256 256 Y EMC
Edition R2, Edition SP1; A7388A (LP1050), 207E; CLARiiON
FCA2214 (QLA2340), AX100
Microsoft Windows 2003 [x86] Standard: Edition, FCA2408 (LP982); EMC Connectrix
Edition R2, Edition SP1 DS−220B−FF−D2;
IBM 24P0960 (QLA2340) McDATA ES−43001
8 Microsoft Windows 2003 [x86] Enterprise: Edition, HPQ: A7298A (LP982), EMC Connectrix: 15 15 256 256 Y EMC
Edition R2, Edition SP1; A7560A (LP1050Ex), DS−4400M, DS−4700M; CLARiiON
FCA2214 (QLA2340), AX100
Microsoft Windows 2003 [x86] Standard: Edition, FCA2408 (LP982); McDATA: ES−4400,
Edition R2, Edition SP1 ES−4700
IBM: 19K1246 (QLA2310),
24P0960 (QLA2340);
NEC N8803−031
(QLA2310F)
9 Microsoft Windows 2003 [x86] Enterprise: Edition, NEC N8190−120 Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
Edition R2, Edition SP1; (LP1050); 207E; CLARiiON
QLogic QLE2360−E−SP AX100
Microsoft Windows 2003 [x86] Standard: Edition, EMC Connectrix
Edition R2, Edition SP1 DS−220B−FF−D2;
McDATA ES−43001
10 Microsoft Windows 2003 [x86] Enterprise: Edition, QLogic QLE2360−E−SP EMC Connectrix: 15 15 256 128, 256 Y EMC
Edition R2, Edition SP1; 3250−VL2E3, CLARiiON
DS−8B2−0DL; AX100
Microsoft Windows 2003 [x86] Standard: Edition,
Edition R2, Edition SP1 QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
11 Microsoft Windows 2003 [x86] Enterprise: Edition, Emulex: LPe111−E, EMC Connectrix: 15 15 256 256 Y EMC
Edition R2, Edition SP1; LPe1150−E; DS−4400M, DS−4700M; CLARiiON
AX100
Microsoft Windows 2003 [x86] Standard: Edition, HPQ A8002A/FC2142SR McDATA: ES−4400,
Edition R2, Edition SP1; (LPe1150); ES−4700
NEC N8190−127
Microsoft Windows 2003 [x86] Storage: Server, Server (LPe1150);
SP1 QLogic QLE220−E−SP
12 Microsoft Windows 2003 [x86] Enterprise: Edition, IBM 39M5894 (QLA2460); Brocade Silkworm: 205E, 15 15 256 256 Y EMC
Edition R2, Edition SP1; QLogic: QLA2460−E−SP, 207E; CLARiiON
QLE220−E−SP, AX100
Microsoft Windows 2003 [x86] Standard: Edition, QLE2460−E−SP, EMC Connectrix:
Edition R2, Edition SP1; QLE2462−E−SP 3250−VL2E3,
DS−220B−FF−D2,
Microsoft Windows 2003 [x86] Storage: Server, Server DS−8B2−0DL;
SP1
McDATA ES−43001;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
13 Microsoft Windows 2003 [x86] Storage: Server, Server EMC Integrated for Netwin Brocade Silkworm: 205E, 15 15 256 128 Y EMC
SP1 200 207E; CLARiiON
AX100
EMC Connectrix:
3250−VL2E3,
DS−220B−FF−D2,
DS−8B2−0DL;
McDATA ES−43001
14 Microsoft Windows 2003 [x86] Storage: Server, Server EMC: Integrated, EMC Connectrix: 15 15 256 128 Y EMC
SP1 Integrated for Netwin 200 DS−4400M, DS−4700M; CLARiiON
AX100
McDATA: ES−4400,
ES−4700
15 Microsoft Windows 2003 [x86] Storage: Server, Server Emulex LP1050Ex−E; EMC Connectrix: 15 15 256 256 Y EMC
SP1 QLogic QLE2360−E−SP DS−4400M, DS−4700M; CLARiiON
AX100
McDATA: ES−4400,
ES−4700
16 Microsoft Windows 2003 [x86] Storage: Server, Server Emulex: LP1050−E, Brocade Silkworm: 205E, 15 15 256 256 Y EMC
SP1 LP1050Ex−E, LP1150−E, 207E; CLARiiON
LP982−E, LPe111−E, AX100
LPe1150−E; EMC Connectrix:
3250−VL2E3,
HPQ A8002A/FC2142SR DS−220B−FF−D2,
(LPe1150); DS−8B2−0DL;
NEC N8190−127
(LPe1150); McDATA ES−43001;
QLogic: QLA2340−E−SP, QLogic SANBox:
QLE2360−E−SP SB1404−10AJ−E,
SB3050−08A−E
17 Microsoft Windows 2003 [x86]: DataCenter, Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
DataCenter R2, DataCenter SP1, Enterprise Edition, LP982−E; DS−4400M, DS−4700M; CLARiiON
Enterprise Edition R2, Enterprise Edition SP1, AX100
Standard Edition, Standard Edition R2, Standard HPQ A7388A (LP1050); McDATA: ES−4400,
Edition SP1 QLogic: ES−4700
QLA2310F−E−SP,
QLA2340−E−SP;
Unisys FCH752313−PCX
(LP1050)
18 Microsoft Windows 2003 [x86]: DataCenter, HPQ A7388A (LP1050) EMC Connectrix: 15 15 256 256 Y EMC
DataCenter R2, DataCenter SP1, Enterprise Edition, DS−4400M, DS−4700M; CLARiiON
Enterprise Edition R2, Enterprise Edition SP1, AX100
Standard Edition, Standard Edition R2, Standard McDATA: ES−4400,
Edition SP1 ES−4700

11/02/2006 201 CLARiiON AX100


CLARiiON AX100

Microsoft Windows 2003 [x86]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
19 Microsoft Windows 2003 [x86]: DataCenter, NEC N8190−120 EMC Connectrix: 15 15 256 128, 256 Y EMC
DataCenter R2, DataCenter SP1, Enterprise Edition, (LP1050); DS−4400M, DS−4700M; CLARiiON
Enterprise Edition R2, Enterprise Edition SP1, QLogic QLE2360−E−SP AX100
Standard Edition, Standard Edition R2, Standard McDATA: ES−4400,
Edition SP1 ES−4700
20 Microsoft Windows 2003 [x86]: DataCenter, Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
DataCenter R2, DataCenter SP1, Enterprise Edition, LP1150−E, LP982−E; DS−4400M, DS−4700M; CLARiiON
Enterprise Edition R2, Enterprise Edition SP1, AX100
Standard Edition, Standard Edition R2, Standard IBM 39M5894 (QLA2460); McDATA: ES−4400,
Edition SP1, Storage Server, Storage Server SP1 QLogic: ES−4700
QLA2310F−E−SP,
QLA2340−E−SP,
QLA2460−E−SP,
QLE2460−E−SP,
QLE2462−E−SP
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
3. This switch is offered by Dell as the Brocade VL2 LC.

MiracleLinux MLSE [32−Bit]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

MiracleLinux MLSE [32−Bit]


Host
Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 MiracleLinux MLSE [32−Bit] 3.0: GA v2.4.21−9.30AX, GA+ Dell Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
v2.4.21−9.38AX, SP1 v2.4.21−20.19AX, SP1+ 2342M Module (SW3014), 4Gb FC Switch CLARiiON
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX; Module (SW4016); AX100
MiracleLinux MLSE [32−Bit] 4.0 GA v2.6.9−11.19AX Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)

MiracleLinux MLSE [AMD64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

MiracleLinux MLSE [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 MiracleLinux MLSE [AMD64]: 3.0 SP2 Dell Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
v2.4.21−37.18AX, 4.0 GA v2.6.9−11.19AX 2342M (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

MiracleLinux MLSE [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

11/02/2006 202 CLARiiON AX100


CLARiiON AX100

MiracleLinux MLSE [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 MiracleLinux MLSE [EM64T] 3.0: GA Dell Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
v2.4.21−20.19AX, GA+ v2.4.21−20.29AX, SP2 2342M (SW3014), 4Gb FC Switch Module CLARiiON
v2.4.21−37.18AX; (SW4016); AX100
MiracleLinux MLSE [EM64T] 4.0 GA Dell McDATA FC Switch Module:
v2.6.9−11.19AX (SW4314), (SW4416);
Dell Optical Pass−thru Module (J6780)

Novell Netware
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Novell Netware
Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Novell Netware: 6.5, 6.5 SP1.1, QLogic QLA2340−E−SP QLogic SANBox 15 15 256 128 Y EMC
6.5 SP2, 6.5 SP3 SB1404−10AJ−E CLARiiON
AX100
2 Novell Netware: 6.5, 6.5 SP1.1, QLogic: QLA200−E−SP, QLogic SANBox 15 15 256 128 Y EMC
6.5 SP2, 6.5 SP3 QLA2340−E−SP SB3050−08A−E CLARiiON
AX100
3 Novell Netware: 6.5, 6.5 SP1.1, QLogic: QLA200−E−SP, EMC Connectrix: 15 15 256 128 Y EMC
6.5 SP2, 6.5 SP3 QLA2340−E−SP, QLE2360−E−SP 3250−VL2E1, DS−8B2−0DL; CLARiiON
AX100
McDATA ES−43002
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

Oracle Enterprise Linux [32−Bit]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Oracle Enterprise Linux [32−Bit]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Oracle Enterprise Linux [32−Bit] 4 Dell: 2342M, Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
U4 v2.6.9−42.0.0.0.1.EL LPe1105−M, (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
QME2462 AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Oracle Enterprise Linux [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

11/02/2006 203 CLARiiON AX100


CLARiiON AX100

Oracle Enterprise Linux [EM64T]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Oracle Enterprise Linux [EM64T] Dell: 2342M, Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
4 U4 v2.6.9−42.0.0.0.1.EL LPe1105−M, (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
QME2462 AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Red Flag DC Server [32−Bit]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Flag DC Server [32−Bit]


Host
Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Flag DC Server [32−Bit] 4.1: GA 2.4.21−9.30AX, GA+ Dell Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
v2.4.21−9.38AX, SP1 v2.4.21−20.19AX, SP1+ 2342M Module (SW3014), 4Gb FC Switch CLARiiON
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX; Module (SW4016); AX100
Red Flag DC Server [32−Bit] 5.0 GA v2.6.9−11.19AX Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)

Red Flag DC Server [AMD64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Flag DC Server [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Flag DC Server [AMD64]: 4.1 SP2 Dell Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
v2.4.21−37.18AX, 5.0 GA v2.6.9−11.19AX 2342M (SW3014), 4Gb FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

Red Flag DC Server [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Flag DC Server [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Flag DC Server [EM64T] 4.1: GA Dell Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
v2.4.21−20.19AX, GA+ v2.4.21−20.29AX, SP2 2342M (SW3014), 4Gb FC Switch Module CLARiiON
v2.4.21−37.18AX; (SW4016); AX100
Red Flag DC Server [EM64T] 5.0 GA Dell McDATA FC Switch Module:
v2.6.9−11.19AX (SW4314), (SW4416);
Dell Optical Pass−thru Module (J6780)

11/02/2006 204 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Hat RHEL [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 QLogic Brocade Silkworm: 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, QLA2340−E−SP 205E, 207E; CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62; EMC Connectrix:
3250−VL2E1,
Red Hat RHEL [32−Bit] 3.0 AS/ES: v2.4.21−4.0.1.EL, v2.4.21−4.EL; DS−220B−FF−D3,
DS−4400M,
Red Hat RHEL [32−Bit] 3.0: U1 AS/ES v2.4.21−9.EL, U1+ AS/ES DS−4700M,
v2.4.21−9.0.1.EL, U2 AS/ES v2.4.21−15.EL, U2+ AS/ES DS−8B2−0DL;
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES McDATA:
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES ES−43002,
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL; ES−4400, ES−4700
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL
2 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 QLogic Brocade Silkworm: 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, QLA200−E−SP 205E, 207E; CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62; EMC Connectrix:
3250−VL2E1,
Red Hat RHEL [32−Bit] 3.0 AS/ES: v2.4.21−4.0.1.EL, v2.4.21−4.EL; DS−220B−FF−D3,
DS−4400M,
Red Hat RHEL [32−Bit] 3.0: U1 AS/ES v2.4.21−9.EL, U1+ AS/ES DS−4700M,
v2.4.21−9.0.1.EL, U2 AS/ES v2.4.21−15.EL, U2+ AS/ES DS−8B2−0DL;
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U4 AS/ES v2.4.21−27.EL, U4+ AS/ES McDATA:
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES ES−43002,
v2.4.21−27.0.4.EL ES−4400, ES−4700
3 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 Emulex: Brocade Silkworm: 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, LP101−E, 205E, 207E; CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES LP982−E AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62; EMC Connectrix:
3250−VL2E1,
Red Hat RHEL [32−Bit] 3.0 AS/ES: v2.4.21−4.0.1.EL, v2.4.21−4.EL; DS−220B−FF−D3,
DS−4400M,
Red Hat RHEL [32−Bit] 3.0: U1 AS/ES v2.4.21−9.EL, U1+ AS/ES DS−4700M,
v2.4.21−9.0.1.EL, U2 AS/ES v2.4.21−15.EL, U2+ AS/ES DS−8B2−0DL;
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U4 AS/ES v2.4.21−27.EL, U4+ AS/ES McDATA:
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES ES−43002,
v2.4.21−27.0.4.EL; ES−4400, ES−4700
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL
4 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 Emulex Brocade Silkworm: 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, LP1050Ex−E 205E, 207E; CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62; EMC Connectrix:
3250−VL2E1,
Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES DS−220B−FF−D3,
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES DS−4400M,
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES DS−4700M,
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES DS−8B2−0DL;
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL;
McDATA:
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL ES−43002,
ES−4400, ES−4700
5 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 Emulex QLogic SANBox: 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, LP1050Ex−E; SB1404−10AJ−E, CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES QLogic SB3050−08A−E AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62; QLA2340−E−SP
Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL;
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL
6 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 QLogic Brocade Silkworm: 15 15 256 128, 256 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, QLE2360−E−SP 205E, 207E; CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62; EMC Connectrix:
3250−VL2E1,
Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES DS−220B−FF−D3,
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES DS−4400M,
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES DS−4700M,
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES DS−8B2−0DL;
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL;
McDATA:
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL ES−43002,
ES−4400,
ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E

11/02/2006 205 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
7 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 QLogic QLogic SANBox 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, QLA200−E−SP SB3050−08A−E CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62;
Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U4 AS/ES v2.4.21−27.EL, U4+ AS/ES
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES
v2.4.21−27.0.4.EL
8 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 Emulex QLogic SANBox 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, LP982−E SB1404−10AJ−E CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62;
Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U4 AS/ES v2.4.21−27.EL, U4+ AS/ES
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES
v2.4.21−27.0.4.EL;
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL
9 Red Hat RHEL [32−Bit] 2.1: U2 v2.4.9−e.24, U2+ v2.4.9−e.27, U3 Emulex: QLogic SANBox 15 15 256 128 Y EMC
AS/ES v2.4.9−e.35, U3+ AS/ES v2.4.9−e.38, U4 AS/ES v2.4.9−e.40, LP101−E, SB3050−08A−E CLARiiON
U4+ AS/ES v2.4.9−e.43, U5 AS/ES v2.4.9−e.49, U6 AS/ES LP982−E AX100
v2.4.9−e.57, U6+ AS/ES v2.4.9−e.59, U7 AS/ES v2.4.9−e.62;
Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES
v2.4.21−15.0.4.EL, U4 AS/ES v2.4.21−27.EL, U4+ AS/ES
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES
v2.4.21−27.0.4.EL;
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL
10 Red Hat RHEL [32−Bit] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES Dell 2342M Dell Brocade: 1/2Gb 15 15 256 256 Y EMC
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES FC Switch Module CLARiiON
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES (SW3014), 4Gb FC AX100
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES Switch Module
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL, U5 AS/ES (SW4016);
v2.4.21−32.EL, U5+ AS/ES v2.4.21−32.0.1.EL, U6 AS/ES
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 AS/ES Dell McDATA FC
v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; Switch Module:
(SW4314),
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL; (SW4416);
Red Hat RHEL [32−Bit] 4.0: U1 AS/ES v2.6.9−11.EL, U2 AS/ES Dell Optical
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Pass−thru Module
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ AS/ES (J6780)
v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL, U4 AS/ES
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL
11 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES Dell: Dell Brocade: 1/2Gb 15 15 256 256 Y EMC
v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES LPe1105−M, FC Switch Module CLARiiON
v2.4.21−47.EL; QME2462 (SW3014), 4Gb FC AX100
Switch Module
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ AS/ES (SW4016);
v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 AS/ES
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Dell McDATA FC
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES Switch Module:
v2.6.9−42.0.2.EL (SW4314),
(SW4416);
Dell Optical
Pass−thru Module
(J6780)
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Red Hat RHEL [AMD−64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Hat RHEL [AMD−64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [AMD−64] 3.0: U4 AS/ES Emulex: LP101−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ LP1050Ex−E, CLARiiON
AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES LP982−E; EMC Connectrix: 3250−VL2E1, AX100
v2.4.21−27.0.4.EL DS−220B−FF−D3, DS−4400M,
QLogic: DS−4700M, DS−8B2−0DL;
QLA200−E−SP,
QLA2340−E−SP McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox SB3050−08A−E

11/02/2006 206 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [AMD−64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
2 Red Hat RHEL [AMD−64] 3.0: U4 AS/ES Emulex: QLogic SANBox 15 15 256 128 Y EMC
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ LP1050Ex−E, SB1404−10AJ−E CLARiiON
AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES LP982−E; AX100
v2.4.21−27.0.4.EL
QLogic
QLA2340−E−SP
3 Red Hat RHEL [AMD−64] 3.0: U4 AS/ES QLogic Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ QLE2360−E−SP CLARiiON
AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES EMC Connectrix: 3250−VL2E1, AX100
v2.4.21−27.0.4.EL DS−220B−FF−D3, DS−4400M,
DS−4700M, DS−8B2−0DL;
McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Red Hat RHEL [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Hat RHEL [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [EM64T] 3.0: U2 AS/ES v2.4.21−15.EL, U2+ AS/ES Dell 2342M Dell Brocade: 1/2Gb 15 15 256 256 Y EMC
v2.4.21−15.0.2.EL, U2+ AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES FC Switch Module CLARiiON
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 AS/ES (SW3014), 4Gb FC AX100
v2.4.21−27.EL, U4+ AS/ES v2.4.21−27.0.1.EL, U4+ AS/ES Switch Module
v2.4.21−27.0.2.EL, U4+ AS/ES v2.4.21−27.0.4.EL, U5 AS/ES (SW4016);
v2.4.21−32.EL, U5+ AS/ES v2.4.21−32.0.1.EL, U6 AS/ES
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 AS/ES Dell McDATA FC
v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; Switch Module:
(SW4314),
Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL, v2.6.9−5.EL; (SW4416);
Red Hat RHEL [EM64T] 4.0: U1 AS/ES v2.6.9−11.EL, U2 AS/ES Dell Optical
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES Pass−thru Module
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ AS/ES (J6780)
v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL, U4 AS/ES
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL
2 Red Hat RHEL [EM64T] 3.0: U4 AS/ES v2.4.21−27.EL, U4+ AS/ES Emulex: Brocade Silkworm: 15 15 256 128 Y EMC
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES LP101−E, 205E, 207E; CLARiiON
v2.4.21−27.0.4.EL LP1050Ex−E, AX100
LP982−E; EMC Connectrix:
3250−VL2E2,
QLogic: DS−220B−FF−D3,
QLA200−E−SP, DS−4400M,
QLA2340−E−SP DS−4700M,
DS−8B2−0DL;
McDATA:
ES−43001,
ES−4400,
ES−4700;
QLogic SANBox
SB3050−08A−E
3 Red Hat RHEL [EM64T] 3.0: U4 AS/ES v2.4.21−27.EL, U4+ AS/ES Emulex: QLogic SANBox 15 15 256 128 Y EMC
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES LP1050Ex−E, SB1404−10AJ−E CLARiiON
v2.4.21−27.0.4.EL LP982−E; AX100
QLogic
QLA2340−E−SP
4 Red Hat RHEL [EM64T] 3.0: U4 AS/ES v2.4.21−27.EL, U4+ AS/ES QLogic Brocade Silkworm: 15 15 256 128, 256 Y EMC
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, U4+ AS/ES QLE2360−E−SP 205E, 207E; CLARiiON
v2.4.21−27.0.4.EL AX100
EMC Connectrix:
3250−VL2E2,
DS−220B−FF−D3,
DS−4400M,
DS−4700M,
DS−8B2−0DL;
McDATA:
ES−43001,
ES−4400,
ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E

11/02/2006 207 CLARiiON AX100


CLARiiON AX100

Red Hat RHEL [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
5 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES Dell: Dell Brocade: 1/2Gb 15 15 256 256 Y EMC
v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES LPe1105−M, FC Switch Module CLARiiON
v2.4.21−47.EL; QME2462 (SW3014), 4Gb FC AX100
Switch Module
Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ AS/ES (SW4016);
v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 AS/ES
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Dell McDATA FC
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES Switch Module:
v2.6.9−42.0.2.EL (SW4314),
(SW4416);
Dell Optical
Pass−thru Module
(J6780)
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. This switch is offered by Dell as the Brocade VL2 LC.
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Red Hat RHEL [IA64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Red Hat RHEL [IA64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [IA64] 2.1 AS/ES: v2.4.18−e.41, v2.4.18−e.43, Emulex: Brocade Silkworm: 15 15 256 128 Y EMC
v2.4.18−e.47, v2.4.18−e.52; LP101−E, 205E, 207E; CLARiiON
LP1050Ex−E, AX100
Red Hat RHEL [IA64]: 2.1 U7 AS/ES v2.4.18−e.56, 3.0 AS/ES LP982−E; EMC Connectrix:
v2.4.21−4.0.1.EL, 3.0 AS/ES v2.4.21−4.EL, 3.0 U1 AS/ES 3250−VL2E2,
v2.4.21−9.EL, 3.0 U1+ AS/ES v2.4.21−9.0.1.EL, 3.0 U4 AS/ES QLogic: DS−220B−FF−D1,
v2.4.21−27.EL, 3.0 U4+ AS/ES v2.4.21−27.0.1.EL, 3.0 U4+ QLA200−E−SP, DS−4400M,
AS/ES v2.4.21−27.0.2.EL, 3.0 U4+ AS/ES v2.4.21−27.0.4.EL QLA2340−E−SP DS−4700M,
DS−8B2−0DL;
McDATA: ES−43003,
ES−4400, ES−4700;
QLogic SANBox
SB3050−08A−E
2 Red Hat RHEL [IA64] 2.1 AS/ES: v2.4.18−e.41, v2.4.18−e.43, Emulex: QLogic SANBox 15 15 256 128 Y EMC
v2.4.18−e.47, v2.4.18−e.52; LP1050Ex−E, SB1404−10AJ−E CLARiiON
LP982−E; AX100
Red Hat RHEL [IA64]: 2.1 U7 AS/ES v2.4.18−e.56, 3.0 AS/ES
v2.4.21−4.0.1.EL, 3.0 AS/ES v2.4.21−4.EL, 3.0 U1 AS/ES QLogic
v2.4.21−9.EL, 3.0 U1+ AS/ES v2.4.21−9.0.1.EL, 3.0 U4 AS/ES QLA2340−E−SP
v2.4.21−27.EL, 3.0 U4+ AS/ES v2.4.21−27.0.1.EL, 3.0 U4+
AS/ES v2.4.21−27.0.2.EL, 3.0 U4+ AS/ES v2.4.21−27.0.4.EL
3 Red Hat RHEL [IA64] 2.1 AS/ES: v2.4.18−e.41, v2.4.18−e.43, QLogic Brocade Silkworm: 15 15 256 128, 256 Y EMC
v2.4.18−e.47, v2.4.18−e.52; QLE2360−E−SP 205E, 207E; CLARiiON
AX100
Red Hat RHEL [IA64]: 2.1 U7 AS/ES v2.4.18−e.56, 3.0 AS/ES EMC Connectrix:
v2.4.21−4.0.1.EL, 3.0 AS/ES v2.4.21−4.EL, 3.0 U1 AS/ES 3250−VL2E2,
v2.4.21−9.EL, 3.0 U1+ AS/ES v2.4.21−9.0.1.EL, 3.0 U4 AS/ES DS−220B−FF−D1,
v2.4.21−27.EL, 3.0 U4+ AS/ES v2.4.21−27.0.1.EL, 3.0 U4+ DS−4400M,
AS/ES v2.4.21−27.0.2.EL, 3.0 U4+ AS/ES v2.4.21−27.0.4.EL DS−4700M,
DS−8B2−0DL;
McDATA: ES−43003,
ES−4400, ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

SuSE SLES [32−Bit]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

11/02/2006 208 CLARiiON AX100


CLARiiON AX100

SuSE SLES [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [32−Bit] 8: SP3 v2.4.21−138, SP3+ v2.4.21−190, QLogic Brocade Silkworm: 15 15 256 128 Y EMC
SP3+ v2.4.21−215, SP3+ v2.4.21−231, SP3+ v2.4.21−241, QLA200−E−SP 205E, 207E; CLARiiON
SP3+ v2.4.21−251, SP3+ v2.4.21−266 AX100
EMC Connectrix:
3250−VL2E1,
DS−220B−FF−D3,
DS−4400M, DS−4700M,
DS−8B2−0DL;
McDATA: ES−43002,
ES−4400, ES−4700;
QLogic SANBox
SB3050−08A−E
2 SuSE SLES [32−Bit] 8: SP3 v2.4.21−138, SP3+ v2.4.21−190, Emulex: Brocade Silkworm: 15 15 256 128 Y EMC
SP3+ v2.4.21−215, SP3+ v2.4.21−231, SP3+ v2.4.21−241, LP101−E, 205E, 207E; CLARiiON
SP3+ v2.4.21−251, SP3+ v2.4.21−266; LP1050Ex−E, AX100
LP982−E; EMC Connectrix:
SuSE SLES [32−Bit] 9: SP1 v2.6.5−7.139, SP1+ v2.6.5−7.145, 3250−VL2E1,
SP1+ v2.6.5−7.147 QLogic DS−220B−FF−D3,
QLA2340−E−SP DS−4400M, DS−4700M,
DS−8B2−0DL;
McDATA: ES−43002,
ES−4400, ES−4700;
QLogic SANBox
SB3050−08A−E
3 SuSE SLES [32−Bit] 8: SP3 v2.4.21−138, SP3+ v2.4.21−190, Emulex: QLogic SANBox 15 15 256 128 Y EMC
SP3+ v2.4.21−215, SP3+ v2.4.21−231, SP3+ v2.4.21−241, LP1050Ex−E, SB1404−10AJ−E CLARiiON
SP3+ v2.4.21−251, SP3+ v2.4.21−266; LP982−E; AX100
SuSE SLES [32−Bit] 9: SP1 v2.6.5−7.139, SP1+ v2.6.5−7.145, QLogic
SP1+ v2.6.5−7.147 QLA2340−E−SP
4 SuSE SLES [32−Bit] 9: SP1 v2.6.5−7.139, SP1+ v2.6.5−7.145, QLogic Brocade Silkworm: 15 15 256 128, 256 Y EMC
SP1+ v2.6.5−7.147 QLE2360−E−SP 205E, 207E; CLARiiON
AX100
EMC Connectrix:
3250−VL2E1,
DS−220B−FF−D3,
DS−4400M, DS−4700M,
DS−8B2−0DL;
McDATA: ES−43002,
ES−4400, ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
5 SuSE SLES [32−Bit]: 10, 9 SP1 v2.6.5−7.139, 9 SP1+ Dell 2342M Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
v2.6.5−7.145, 9 SP1+ v2.6.5−7.147, 9 SP1+ v2.6.5−7.151, 9 Switch Module CLARiiON
SP2+ v2.6.5−7.201, 9 SP2+ v2.6.5−7.202.7, 9 SP3 (SW3014), 4Gb FC AX100
v2.6.5−7.244, 9 SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 Switch Module
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9 SP3+ v2.6.5−7.282 (SW4016);
Dell McDATA FC Switch
Module: (SW4314),
(SW4416)
6 SuSE SLES [32−Bit]: 10, 9 SP1+ v2.6.5−7.151, 9 SP2+ Dell 2342M Dell Optical Pass−thru 15 15 256 256 Y EMC
v2.6.5−7.201, 9 SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 Module (J6780) CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 SP3+ v2.6.5−7.267, AX100
9 SP3+ v2.6.5−7.276, 9 SP3+ v2.6.5−7.282
7 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 SP2+ Dell: Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 SP3+ v2.6.5−7.252, 9 LPe1105−M, Switch Module CLARiiON
SP3+ v2.6.5−7.257, 9 SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, QME2462 (SW3014), 4Gb FC AX100
9 SP3+ v2.6.5−7.282 Switch Module
(SW4016);
Dell McDATA FC Switch
Module: (SW4314),
(SW4416);
Dell Optical Pass−thru
Module (J6780)
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

SuSE SLES [AMD−64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

11/02/2006 209 CLARiiON AX100


CLARiiON AX100

SuSE SLES [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [AMD−64] 8: SP3 v2.4.21−143, SP3+ QLogic Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−215, SP3+ v2.4.21−231, SP3+ QLA200−E−SP CLARiiON
v2.4.21−241, SP3+ v2.4.21−251, SP3+ EMC Connectrix: 3250−VL2E1, AX100
v2.4.21−266 DS−220B−FF−D3, DS−4400M,
DS−4700M, DS−8B2−0DL;
McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox SB3050−08A−E
2 SuSE SLES [AMD−64] 8: SP3 v2.4.21−143, SP3+ Emulex: LP101−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−215, SP3+ v2.4.21−231, SP3+ LP1050Ex−E, CLARiiON
v2.4.21−241, SP3+ v2.4.21−251, SP3+ LP982−E; EMC Connectrix: 3250−VL2E1, AX100
v2.4.21−266; DS−220B−FF−D3, DS−4400M,
QLogic DS−4700M, DS−8B2−0DL;
SuSE SLES [AMD−64] 9: SP1 v2.6.5−7.139, SP1+ QLA2340−E−SP
v2.6.5−7.145, SP1+ v2.6.5−7.147 McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox SB3050−08A−E
3 SuSE SLES [AMD−64] 8: SP3 v2.4.21−143, SP3+ Emulex: QLogic SANBox SB1404−10AJ−E 15 15 256 128 Y EMC
v2.4.21−215, SP3+ v2.4.21−231, SP3+ LP1050Ex−E, CLARiiON
v2.4.21−241, SP3+ v2.4.21−251, SP3+ LP982−E; AX100
v2.4.21−266;
QLogic
SuSE SLES [AMD−64] 9: SP1 v2.6.5−7.139, SP1+ QLA2340−E−SP
v2.6.5−7.145, SP1+ v2.6.5−7.147
4 SuSE SLES [AMD−64] 9: SP1 v2.6.5−7.139, SP1+ QLogic Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
v2.6.5−7.145, SP1+ v2.6.5−7.147 QLE2360−E−SP CLARiiON
EMC Connectrix: 3250−VL2E1, AX100
DS−220B−FF−D3, DS−4400M,
DS−4700M, DS−8B2−0DL;
McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox:
SB1404−10AJ−E, SB3050−08A−E
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

SuSE SLES [EM64T]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

SuSE SLES [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Dell: Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
v2.6.5−7.202.7; LPe1105−M, Switch Module (SW3014), CLARiiON
QME2462 4Gb FC Switch Module AX100
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+ (SW4016);
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267,
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 Dell McDATA FC Switch
Module: (SW4314),
(SW4416);
Dell Optical Pass−thru
Module (J6780)
2 SuSE SLES [EM64T] 9: SP1 v2.6.5−7.139, SP1+ Emulex: Brocade Silkworm: 205E, 15 15 256 128 Y EMC
v2.6.5−7.145, SP1+ v2.6.5−7.147 LP101−E, 207E; CLARiiON
LP1050Ex−E, AX100
LP982−E; EMC Connectrix:
3250−VL2E1,
QLogic DS−220B−FF−D3,
QLA2340−E−SP DS−4400M, DS−4700M,
DS−8B2−0DL;
McDATA: ES−43002,
ES−4400, ES−4700;
QLogic SANBox
SB3050−08A−E
3 SuSE SLES [EM64T] 9: SP1 v2.6.5−7.139, SP1+ Emulex: QLogic SANBox 15 15 256 128 Y EMC
v2.6.5−7.145, SP1+ v2.6.5−7.147 LP1050Ex−E, SB1404−10AJ−E CLARiiON
LP982−E; AX100
QLogic
QLA2340−E−SP

11/02/2006 210 CLARiiON AX100


CLARiiON AX100

SuSE SLES [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
4 SuSE SLES [EM64T] 9: SP1 v2.6.5−7.139, SP1+ QLogic Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
v2.6.5−7.145, SP1+ v2.6.5−7.147 QLE2360−E−SP 207E; CLARiiON
AX100
EMC Connectrix:
3250−VL2E1,
DS−220B−FF−D3,
DS−4400M, DS−4700M,
DS−8B2−0DL;
McDATA: ES−43002,
ES−4400, ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
5 SuSE SLES [EM64T] 9: SP1+ v2.6.5−7.151, SP2+ Dell 2342M Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
v2.6.5−7.201, SP2+ v2.6.5−7.202.7, SP3 v2.6.5−7.244, Switch Module (SW3014), CLARiiON
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ 4Gb FC Switch Module AX100
v2.6.5−7.267, SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 (SW4016);
Dell McDATA FC Switch
Module: (SW4314),
(SW4416);
Dell Optical Pass−thru
Module (J6780)
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

SuSE SLES [IA64]


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

SuSE SLES [IA64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [IA64] 8: SP3 v2.4.21−112, SP3+ QLogic Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−190, SP3+ v2.4.21−215, SP3+ v2.4.21−231, QLA200−E−SP CLARiiON
SP3+ v2.4.21−241, SP3+ v2.4.21−251, SP3+ EMC Connectrix: 3250−VL2E3, AX100
v2.4.21−266 DS−220B−FF−D1, DS−4400M,
DS−4700M, DS−8B2−0DL;
McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox SB3050−08A−E
2 SuSE SLES [IA64] 8: SP3 v2.4.21−112, SP3+ Emulex: Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−190, SP3+ v2.4.21−215, SP3+ v2.4.21−231, LP101−E, CLARiiON
SP3+ v2.4.21−241, SP3+ v2.4.21−251, SP3+ LP1050Ex−E, EMC Connectrix: 3250−VL2E3, AX100
v2.4.21−266; LP982−E; DS−220B−FF−D1, DS−4400M,
DS−4700M, DS−8B2−0DL;
SuSE SLES [IA64] 9 SP1+: v2.6.5−7.145, QLogic
v2.6.5−7.147 QLA2340−E−SP McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox SB3050−08A−E
3 SuSE SLES [IA64] 8: SP3 v2.4.21−112, SP3+ Emulex: QLogic SANBox 15 15 256 128 Y EMC
v2.4.21−190, SP3+ v2.4.21−215, SP3+ v2.4.21−231, LP1050Ex−E, SB1404−10AJ−E CLARiiON
SP3+ v2.4.21−241, SP3+ v2.4.21−251, SP3+ LP982−E; AX100
v2.4.21−266;
QLogic
SuSE SLES [IA64] 9 SP1+: v2.6.5−7.145, QLA2340−E−SP
v2.6.5−7.147
4 SuSE SLES [IA64] 9 SP1+: v2.6.5−7.145, QLogic Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
v2.6.5−7.147 QLE2360−E−SP CLARiiON
EMC Connectrix: 3250−VL2E3, AX100
DS−220B−FF−D1, DS−4400M,
DS−4700M, DS−8B2−0DL;
McDATA: ES−43002, ES−4400,
ES−4700;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

SuSE SLES [x86_64]

11/02/2006 211 CLARiiON AX100


CLARiiON AX100

"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

SuSE SLES [x86_64]


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES Dell: 2342M, Dell Brocade: 1/2Gb FC Switch Module (SW3014), 4Gb 15 15 256 256 Y EMC
[x86_64] 10 LPe1105−M, QME2462 FC Switch Module (SW4016); CLARiiON
AX100
Dell McDATA FC Switch Module: (SW4314), (SW4416);
Dell Optical Pass−thru Module (J6780)

Sun Solaris
"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Sun Solaris
Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Sun Solaris: QLogic QLA2340−E−SP; Brocade Silkworm: 205E, 207E; 4 15 256 128 Y EMC
10, 8, 9 Sun: SG−XPCI1FC−QL2 (QLA2340), CLARiiON
X6767A (SG−XPCI1FC−QF2) EMC Connectrix: 3250−VL2E2, DS−220B−FF−D3, AX100
DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43001, ES−4400, ES−4700
2 Sun Solaris: Sun SG−XPCI1FC−EM2 (LP10000) Brocade Silkworm: 205E, 207E; 4 15 256 128 Y EMC
8, 9 CLARiiON
EMC Connectrix: 3250−VL2E2, DS−220B−FF−D3, AX100
DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43001, ES−4400, ES−4700
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. This switch is offered by Dell as the Brocade VL2 LC.
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Sun Solaris x86


"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

Sun Solaris x86


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Sun Solaris Sun SG−XPCI1FC−QL2 Brocade Silkworm: 205E, 207E; 4 15 256 128 Y EMC
x86 10 (QLA2340) CLARiiON
EMC Connectrix: 3250−VL2E3, DS−220B−FF−D2, AX100
DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43001, ES−4400, ES−4700
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
3. This switch is offered by Dell as the Brocade VL2 LC.

VMware ESX Server

11/02/2006 212 CLARiiON AX100


CLARiiON AX100

"Fanout" represents the maximum initiators(host adapters) per array port. "Fanin" represents the number of array ports visible to a single initiator(host
adapter).
These numbers are achieved through Zoning.
"Port Sharing" allows any OS/HBA designated with a "Y"(for Yes) to safely share an array port with any other OS/HBA designated with a "Y" provided all of
the following requirements are met (Note" "N" for NO means this Operating System/HBA cannot share an array port with any dissimilar OS/HBA combination).
1. EMC LUN Masking Software (ESN Manager, SANManager, or AccessLogix) is required to prevent sharing LUNs between Operating Systems on a single
array port.
2. Fanout/Fanin is restricted to the lowest value associated with Operating System/HBA combinations sharing the array port.
For Switch Firmware levels and other fabric parameters, see the Switched Fabric Topology Parameters table.

VMware ESX Server


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array Comments
1 VMware ESX HPQ Dual−port Fibre HPQ Proliant BL p−Class patch panel [FC 15 15 256 256 Y EMC See5
Server: Channel Adapter for HP Pass−through] (306465−B21) CLARiiON
v2.5.1, Proliant BL20p: (G2) AX1004
v2.5.2, 300874−B21, (G3)
v2.5.3, 361426−B21;
v2.5.4
HPQ Dual−port Fibre
Channel Adapter for HP
Proliant: BL25p/BL45p
381881−B21,
BL30p/BL35p
354054−B21
2 VMware ESX IBM 24P0960 (QLA2340); Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC See5
Server: QLogic QLA2340−E−SP CLARiiON
v2.5.1, EMC Connectrix: 3250−VL2E2, DS−220B−FF−D1, AX1004
v2.5.2, DS−4400M, DS−4700M, DS−8B2−0DL;
v2.5.3,
v2.5.4 McDATA: ES−43003, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
3 VMware ESX IBM HS20 FC Exp Card: IBM Brocade: Enterprise SAN Switch Module For 15 15 256 256 Y EMC See5
Server: (13N2203), (13N2203) for BladeCenter Servers (90P0165), Entry SAN Switch CLARiiON
v2.5.1, IBM eServer LS20, Module For BladeCenter Servers (26K5601); AX1004
v2.5.2, (26K4841), (48P7061)
v2.5.3, IBM: McData 6−Port Switch Module For BladeCenter
v2.5.4 Servers (32R1790), Optical Passthrough Module For
BladeCenter Servers (02R9080), QLogic 2−Port Switch
Module For BladeCenter Servers (48P7062), QLogic
6−Port Switch Module For BladeCenter Servers
(26K6477)
4 VMware ESX QLogic QLE2360−E−SP Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC See5
Server: CLARiiON
v2.5.1, EMC Connectrix: 3250−VL2E2, DS−220B−FF−D1, AX1004
v2.5.2, DS−4400M, DS−4700M, DS−8B2−0DL;
v2.5.3,
v2.5.4 McDATA: ES−43003, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
5 VMware ESX Emulex: LP1050−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC See5
Server: LP1050Ex−E, LP982−E; CLARiiON
v2.5.3, EMC Connectrix: 3250−VL2E2, DS−220B−FF−D1, AX1004
v2.5.4 NEC N8190−120 DS−4400M, DS−4700M, DS−8B2−0DL;
(LP1050)
McDATA: ES−43003, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
6 VMware ESX Dell 2342M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 4Gb 15 15 256 256 Y EMC
Server: FC Switch Module (SW4016); CLARiiON
v2.5.3, AX100
v2.5.4, v3.0, Dell McDATA FC Switch Module: (SW4314),
v3.0.1 (SW4416);
Dell Optical Pass−thru Module (J6780)
7 VMware ESX Dell LPe1105−M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 4Gb 15 15 256 256 Y EMC
Server: v3.0, FC Switch Module (SW4016); CLARiiON
v3.0.1 AX100
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)
8 VMware ESX Emulex: LP1050Ex−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
Server: v3.0, LP982−E; CLARiiON
v3.0.1 EMC Connectrix: 3250−VL2E2, DS−220B−FF−D1, AX100
QLogic QLA2340−E−SP DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43003, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
9 VMware ESX QLogic QLE2360−E−SP Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
Server: v3.0, CLARiiON
v3.0.1 EMC Connectrix: 3250−VL2E2, DS−220B−FF−D1, AX100
DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43003, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
4. CLARiiON AX100 is supported with VMware ESX Server starting with FLARE R19.
5. VMWare ESX does not have dependencies on specific FC−switches and has been found to be broadly interoperable with current generation FC−SW2 compliant Fibre Channel switches.
The listed FC−switches reflect the configurations qualified for support with EMC storage arrays.

11/02/2006 213 CLARiiON AX100


General Information for AX150
Configuration Rules: AX150 Storage Systems
Note: In this document, array means storage system.
• A total of 10 servers are supported per storage system.
• A total of 10 Host Bus Adapters (HBAs) are supported on single−SP AX150 storage systems.
• A total of 20 HBAs are supported on dual−SP AX150 storage systems.
• A total of 4 storage systems per server are supported.
• A total of 256 virtual disks per storage system are supported.
• User installable HBAs are limited to the Emulex and the QLogic E models.
• HBAs from different manufacturers cannot be mixed in the same server.
• User installable switches are limited to the QLogic SB3050−08A−E and the QLogic SANbox SB1404−10AJ−E, the Brocade DS−3250−VL2E and the
Brocade DS−220B−FF−D, DS−210B−DEU and the DS−210B−DE. Pre−configured zoning or the Zoning Wizard must be used with these switches to
be user installable. All other supported switches are not user installable and require professional installation.
• Switches from different manufacturers cannot be mixed in the same SAN.
• If an AX100 series system is connected to a server, no other type of storage system can be connected to that server.
• A server must be connected to a storage system either directly or through a switch. A server CANNOT be connected to the SAME storage system
both directly and through a switch.
• All direct connect configurations are user installable.
• For example, figures 1 and 2.
• Any switch configuration utilizing an Inter Switch Link (ISL) is not user installable. No more than 2 switches can be connected with an ISL.
• For example, figures 14 and 15.
• In any supported multiple−server configuration, the servers can run the same operating system or any combination of supported operating systems.
• The snapshot feature requires that the source and secondary servers are connected to the same SP. As a result, the snapshot feature is not
supported for figures 4 and 5.
• PowerPath must be installed on all attached servers for all configurations.
• A clustered configuration requires one or more HBAs per server and a single−SP or dual−SP storage system.
• 2 to 8 nodes are supported in a clustered configuration.
• All nodes in a cluster configuration must run the same operating system. Diagrams may show other operating systems, but dissimilar operating
systems cannot be clustered.
• All nodes in a cluster configuration must be connected to the same SPs.

• For example, figures 2, 7 and 8.


• The installation of an operating system on a storage system for the purpose of booting the server from the storage system is not a user installable
option.
• Boot from a storage system on clustered servers running Windows 2000 require a dedicated boot HBA.
• Boot from a storage system on clustered servers running Windows 2003 DO NOT require a dedicated boot HBA.

Backup Device Support


EMC's testing and qualification responsibilities only apply to SAN (switch) attached backup devices. SAN attached backup configurations include a backup
device connected to a port on the switch. These configurations are not currently user installable. Please refer to the EMC ESM for SAN attached backup
supported configurations.

For tape devices connected directly to a backup host, EMC strongly recommends that the component vendors' supported configuration matrices are reviewed
(host configuration matrix for compatibility with SCSI or Fibre Channel interface used to connect to tape device, tape device vendor for compatibility with
selected SCSI or Fibre Channel interface and backup software vendor for compatibility with the tape device).

Path Definition
A path is a connection between an HBA port and a target SP port in a storage system. Each HBA that is directly connect to, or zoned through, a switch to an SP
port is considered an initiator of that SP port. An HBA port can be zoned through different switch ports to the same SP port or to different SP ports, resulting in
multiple paths between the HBA port and an SP.

Remote Replication
For customers planning to utilize the AX150 along with CLARiiON arrays running EMC SAN Copy software, adding SAN Copy/E software to the AX150
provides the ability to replicate data from the AX150 via Navisphere. For example, using the AX150, SAN Copy/E can be used to replciate data from branch
offices back to the data center to provide disaster recovery protection and to consolidate the backup process. The SAN Copy/E application on an AX150 is
qualified for connectivity to the CX arrays running SAN Copy (for the SAN Copy application only, not host attach) through professionally installed switches listed
on the AX Support Matrix. For cost effective remote replication solutions, as well as low cost DR implementations, the QLogic iSR6142 SAN Router has been
qualified.

11/02/2006 214 General Information for AX150


AX Series EMC Partner Solutions
EMC has a wide variety of distribution partners that offer the AX Series product. The information in this document contains supported components that are
'standard' across our AX Series product solutions. EMC's AX Series partners offer a wider variety of the AX Series solutions to fit your business needs. For a
complete listing of current EMC distribution partners and their AX Series specific solutions, please refer to the EMC AX Series website with direct links to these
partners. The specific link to this EMC site is:
http://www.emc.com/partnersalliances/partners/sp.jsp
For general information about the EMC AX Series Storage System, please follow the link below:
http://www.emc.com/products/systems/clariion/ax150/index.jsp

11/02/2006 215 AX Series EMC Partner Solutions


CLARiiON AX150
Base Connectivity
Fujitsu Siemens Solaris

Fujitsu Siemens Solaris


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Fujitsu PCI Fujitsu Siemens: LP10000−E (GP70F−CF33)3, 4, 5, 7, 8, 9, 10, 11, 12 , LP11000−E FC−AL, EMC N
PRIMEPOWER: 200, 250, Siemens (GP70F−CF36)3, 4, 5, 6, LP9002−E (LP9002L−E) GP70F−CF303, 5, 10, 11, 12, 17, 18, 19, 20 , FC−SW CLARiiON
400, 450, 600, 650, 850 Solaris 101, LP9802−E (GP70F−CF31)3, 4, 5, 7, 8, 9, 10, 11, 17, 18 AX150
2

2 Fujitsu Siemens Fujitsu PCI Fujitsu Siemens: LP10000−E (GP70F−CF33)3, 4, 5, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 , FC−AL, EMC N
PRIMEPOWER: 200, 250, Siemens LP11000−E (GP70F−CF36)3, 4, 5, 6, 13, 14, 15, 16 , LP9802−E (GP70F−CF31)3, 4, 5, 7, 8, 9, FC−SW CLARiiON
400, 450, 600, 650, 850 Solaris: 8, 9 10, 11, 12, 13, 14, 15, 16 AX150
1. FSC requires all patches for Solaris 10 be obtained through FSC in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers running
Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
2. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
3. FCode Value 1.50a4
4. SNIA HBA API Supported.
5. FCode Value 1.41a4
6. Firmware Version 2.10a9
7. Firmware Version 1.91a1
8. Firmware Version 1.90a4
9. Driver Version 6.02e
10. Driver Version 6.02f
11. Driver Version 6.02hx2
12. Driver Version 6.01f
13. Driver Version SAN 4.4.10
14. Driver Version SAN 4.4.7a
15. Driver Version SAN 4.4.9
16. Driver Version SAN 4.4.8
17. The SAN driver is part of the OS.
18. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
19. Firmware Version 3.92a3
20. Driver Version 5.01e

Fujitsu Solaris

Fujitsu Solaris
Operating Host External
No. Host System System Bus Host Bus Adapter Topology Storage Array Boot Comments
1 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Emulex: LP10000−E4, 5, 6, 7, 8, 9, 10, 14, 15, 16 , FC−AL, EMC Y See12
2500, 450, 650, 850, 900 1017, 18 LP9802−E4, 5, 6, 7, 8, 9, 10, 14, 15, 16 FC−SW CLARiiON
AX150
2 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris PCI Fujitsu: PW008FC219, PW008FC319 FC−AL, EMC N See12
2500, 450, 650, 850, 900 1017, 18 FC−SW CLARiiON
AX150
3 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 8 PCI Emulex LP9802−E1, 2, 3, 4, 5, 6, 7, 8, 9, 10 FC−AL, EMC Y See12
2500, 450, 650, 850, 900 02/0213 FC−SW CLARiiON
AX150
4 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 8 PCI Fujitsu: PW008FC220, 21, 22, 23 , PW008FC320, 21, 22, 23 FC−AL, EMC N See12
2500, 450, 650, 850, 900 02/0213 FC−SW CLARiiON
AX150
5 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 9 PCI Emulex LP9802−E1, 2, 3, 4, 5, 6, 7, 8, 9, 10 FC−AL, EMC Y See12
2500, 450, 900 04/0311 FC−SW CLARiiON
AX150
6 Fujitsu PRIMEPOWER: 1500, 250, Fujitsu Solaris 9 PCI Fujitsu: PW008FC220, 21, 22, 23 , PW008FC320, 21, 22, 23 FC−AL, EMC N See12
2500, 450, 900 04/0311 FC−SW CLARiiON
AX150
7 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris 9 PCI Emulex LP9802−E1, 2, 3, 4, 5, 6, 7, 8, 9, 10 FC−AL, EMC Y See12
12/0211 FC−SW CLARiiON
AX150
8 Fujitsu PRIMEPOWER: 650, 850 Fujitsu Solaris 9 PCI Fujitsu: PW008FC220, 21, 22, 23 , PW008FC320, 21, 22, 23 FC−AL, EMC N See12
12/0211 FC−SW CLARiiON
AX150
1. Driver Version SAN 4.4.7a
2. Driver Version SAN 4.4.8
3. Driver Version 6.01f
4. Driver Version 6.02f
5. FCode Value 1.41a4
6. SNIA HBA API Supported.
7. Firmware Version 1.91a1
8. FCode Value 1.50a4
9. Driver Version 6.02e
10. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
11. Fujitsu requires that all patches for Solaris 9 be obtained through Fujitsu in the form of a Solaris 9 PTF patch CD. The current patch CD is Solaris 9 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 9: 112233−12, 112834−06, 113277−45, 117171−17, 118558−30, and PTF R06081
12. For use in Asia Pacific/Japan only. Refer to Fujitsu Siemens Base Connectivity information for US/Europe.
13. Fujitsu requires all patches for Solaris 8 be obtained through Fujitsu in the form of a Solaris 8 PTF patch CD. The current patch CD is Solaris 8 PTF R06081. EMC requires Solaris
patches for Fujitsu PCI Bus servers running Solaris 8: 108528−29, 117000−05, 108974−50,109885−20, 110918−06, 117350−39 and PTF R06081
14. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing required patch 120222−04. These packages are
available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
15. Firmware Version 1.90a4
16. Driver Version SAN in Solaris 10 U1 (01/06)
17. Only PrimePower servers with SPARC64−IV or SPARC64−V cpu's are supported with Solaris 10.
18. Fujitsu requires all patches for Solaris 10 be obtained through Fujitsu in the form of a Solaris 10 PTF patch CD. The current patch CD is Solaris 10 PTF R06081 and PCI Bus servers
running Solaris 10: 118822−30, 118833−20, 119130−22, and 120222−11.
19. Use the Solaris 10 bundled driver PFCA 3.0 which requires patch 120811−02. PFCA Utility 3.0 and its patch 914180−01 need to be installed.

11/02/2006 216 CLARiiON AX150


CLARiiON AX150

20. Driver Version PFCA 2.2.1 requires patch 912069−21.


21. Driver Version PFCA 3.0 requires patch 914180−01.
22. Driver Version PFCA 3.0
23. Driver Version PFCA 2.2.1

Haansoft Asianux Server 2.0 [32−Bit]

Haansoft Asianux Server 2.0 [32−Bit]


Host Bus Storage External
No. Host System Operating System Host Bus Adapter Topology Array Boot
1 HPQ Proliant: DL3202, DL360(G2)2, DL3602, DL380(G2)2, DL380(G3)2, DL3802, Haansoft Asianux PCI QLogic FC−AL, EMC Y
DL580(G2)2, DL5802, ML350(G2)2, ML350(G3)2, ML3502, ML370(G2)2, ML3702, Server 2.0 [32−Bit] SP1 QLE220−E−SP1, FC−SW CLARiiON
ML530(G2)2, ML530(G3)2, ML5302, ML5702, ML7502 v2.6.9−34.21AX3, 4 5, 6, 7 AX150
2 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Haansoft Asianux PCI Emulex FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express LPe111−E7, 8, FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.21AX3, 4 9, 10 AX150
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)2, DL380(G4)2, DL580(G3)2, ML350(G4)2, ML370(G4)2;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
3 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 5, 6, 7 AX150
4 Dell PowerEdge 1950 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express QLE220−E−SP5, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 6, 7 AX150
5 Dell PowerEdge: 2900, 2950, 6950; Haansoft Asianux PCI Emulex FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, LPe111−E7, 8, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX3, 4 PCI−X 9, 10 AX150
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)2 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 PCI−X 5, 6, 7 AX150
7 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, 6950; Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP5, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX3, 4 PCI−X 6, 7 AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
8 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 PCI−X11 5, 6, 7 AX150
9 Digital Henge SH4500R4; Haansoft Asianux PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; Server 2.0 [32−Bit] SP1 QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 5, 6, 7 AX150
HPQ Proliant: BL40p, DL360(G3)2, DL360(G4)2, DL5602, DL7402, DL760 (G2)2,
DL7602, ML570(G2)2;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
10 Dell PowerEdge: 1800, 2800 Haansoft Asianux PCI, PCI QLogic FC−AL, EMC Y
Server 2.0 [32−Bit] SP1 Express, QLE220−E−SP5, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 PCI−X 6, 7 AX150
11 HPQ Proliant: DL1452, DL380(G2)2, DL380(G3)2, DL380(G4)2, DL3802, DL3852, Haansoft Asianux PCI, QLogic FC−AL, EMC Y
DL580(G2)2, DL580(G3)2, DL5852, ML370(G3)2, ML370(G4)2; Server 2.0 [32−Bit] SP1 PCI−X QLE220−E−SP1, FC−SW CLARiiON
v2.6.9−34.21AX3, 4 5, 6, 7 AX150
Samsung SS140
1. Driver/BIOS are available at http://www.qlogic.com
2. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
3. Native multipathing is not supported on boot−from−SAN configurations.
4. Based on Asianux 2.0.
5. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
6. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
7. SNIA HBA API Supported.
8. Driver Version 8.0.16.18 Driver is integrated into the kernel.
9. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Haansoft Asianux Server 2.0 [AMD64]

Haansoft Asianux Server 2.0 [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge 6950; Haansoft Asianux Server 2.0 [AMD64] SP1 PCI Express, Emulex LPe111−E1, 6, 7, 13 FC−AL, EMC CLARiiON Y
IBM eServer 326m (Model v2.6.9−34.21AX4, 5 PCI−X FC−SW AX150
7969)

11/02/2006 217 CLARiiON AX150


CLARiiON AX150

Haansoft Asianux Server 2.0 [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
2 Dell PowerEdge 6950 Haansoft Asianux Server 2.0 [AMD64] SP1 PCI Express, QLogic QLE220−E−SP1, 9, 10 FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX4, 5 PCI−X FC−SW AX150
3 Sun: x4100, x4200 Haansoft Asianux Server 2.0 [AMD64] SP1 PCI−X Emulex: LP1050−E1, 6, 7, 8, FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX4, 5 LP982−E1, 6, 7; FC−SW AX150
QLogic QLA2340−E−SP1, 2, 3
4 HPQ Proliant: DL14511, Haansoft Asianux Server 2.0 [AMD64] SP1 PCI, PCI−X QLogic QLE220−E−SP1, 9, 10, 12 FC−AL, EMC CLARiiON Y
DL38511, DL58511 v2.6.9−34.21AX4, 5 FC−SW AX150
1. SNIA HBA API Supported.
2. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
3. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Native multipathing is not supported on boot−from−SAN configurations.
5. Based on Asianux 2.0.
6. Driver Version 8.0.16.18 Driver is integrated into the kernel.
7. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. Firmware Version 1.91a5
9. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
10. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
11. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
12. Driver/BIOS are available at http://www.qlogic.com
13. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

Haansoft Asianux Server 2.0 [EM64T]

Haansoft Asianux Server 2.0 [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, Haansoft Asianux Server 2.0 [EM64T] PCI Express Emulex FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX2, 3 LPe111−E4, 7, 8, 9 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)10, DL380(G4)10,
DL580(G3)10, ML350(G4)10, ML370(G4)10;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
2 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux Server 2.0 [EM64T] PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
3 Dell PowerEdge 1950 Haansoft Asianux Server 2.0 [EM64T] PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP4, 5, FC−SW CLARiiON
6 AX150
4 Dell PowerEdge: 2900, 2950; Haansoft Asianux Server 2.0 [EM64T] PCI Express, Emulex FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X LPe111−E4, 7, 8, 9 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
5 HPQ Proliant ML350(G4)10 Haansoft Asianux Server 2.0 [EM64T] PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
6 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, Haansoft Asianux Server 2.0 [EM64T] PCI Express, QLogic FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX2, 3 PCI−X QLE220−E−SP4, 5, FC−SW CLARiiON
6 AX150
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
7 Digital Henge Revo: JS1400, JS2400 Haansoft Asianux Server 2.0 [EM64T] PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X11 QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
8 Digital Henge SH4500R4; Haansoft Asianux Server 2.0 [EM64T] PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP1, 4, FC−SW CLARiiON
TX300 S2; 5, 6 AX150
HPQ Proliant DL360(G4)10;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003
9 HPQ Proliant DL580(G3)10 Haansoft Asianux Server 2.0 [EM64T] PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 Express, PCI−X QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
10 Dell PowerEdge: 1800, 2800 Haansoft Asianux Server 2.0 [EM64T] PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 Express, PCI−X QLE220−E−SP4, 5, FC−SW CLARiiON
6 AX150
11 HPQ Proliant: DL380(G4)10, ML370(G4)10 Haansoft Asianux Server 2.0 [EM64T] PCI, PCI−X QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
1. Driver/BIOS are available at http://www.qlogic.com
2. Native multipathing is not supported on boot−from−SAN configurations.
3. Based on Asianux 2.0.
4. SNIA HBA API Supported.
5. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
6. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
7. Driver Version 8.0.16.18 Driver is integrated into the kernel.
8. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
9. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.

11/02/2006 218 CLARiiON AX150


CLARiiON AX150

11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Microsoft Windows 2000


Where replication of boot LUN is supported, any use of the replicated boot LUN other than in original host may lead to hardware/configuration mismatch that
render the replicated boot LUN unusable. Any issues that arise in trying to use the boot LUN in a host that is non−identical to the source host is outside of the
scope of what EMC can support. Also, in any case due to environment failure where I/O is not written back to the source LUN, or if the source LUN is not left
in a stable state by the source host, the replicated LUN is not guaranteed to be any more usable than the source. Also, there may be specific software
licensing that needs to be investigated when duplicating the boot LUN.

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
1 Unisys: ES7000/510, ES7000/520, ES7000/530, Microsoft PCI Unisys FCH752313−PCX (LP1050)2, 50, FC−AL, EMC Y3
ES7000/540, ES7000/550, ES7000/560 [32−Bit] Windows 2000 68 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
2 Dell PowerEdge 1950; Microsoft PCI Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Samsung: ZSS230, ZSS230D Windows 2000 Express FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
3 Samsung: ZSS230, ZSS230D Microsoft PCI Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
Windows 2000 Express FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
4 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic QLA2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4 See16
Windows 2000 Express FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
5 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000 Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Advanced PCI−X AX150
Server: SP4,
Digital Henge Revo: AS1500, AS1550, AS2500; SP49;
IBM xSeries: x336 (8837)44, x346 (8840)44; Microsoft
Windows 2000
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Server SP4
SR1500/S5000PAL, SR2400/SE7520JR2,
SR2500/S5000PAL, SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
Samsung ZSS132
6 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
Windows 2000 Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X AX150
SR2400/SE7520JR2, Server: SP4,
SR4850HW4−M/SR6850HW4−M, SP49;
SR4850HW4/SR6850HW4;
Microsoft
Lenovo SureServer: R630 G5, R650, R650 G5, T650 Windows 2000
Server SP4
7 IBM xSeries: x336 (8837)44, x346 (8840)44 Microsoft PCI IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
Windows 2000 Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
8 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic QLA2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4 See16
Windows 2000 Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X AX150
SR2400/SE7520JR2, Server: SP4,
SR4850HW4−M/SR6850HW4−M, SP49;
SR4850HW4/SR6850HW4;
Microsoft
Lenovo SureServer: R630 G5, R650, R650 G5, T650 Windows 2000
Server SP4
9 IBM xSeries x3850/x366 (8863)52 Microsoft PCI−X IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3, 41
Windows 2000 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4

11/02/2006 219 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
10 IBM xSeries: x23561, x36061, x365, x44061 Microsoft PCI−X IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
Windows 2000 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
11 IBM xSeries x3800/x260 (8865)52 Microsoft PCI−X51 Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
12 IBM xSeries: x3800/x260 (8865)52, x3950/x3950E/x460 Microsoft PCI−X51 IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3, 41
(8872, 8874)52 Windows 2000 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
13 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 Emulex: LP1050−E2, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
Windows 2000 LP1150−E2, 5, 6, 7, 8 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
14 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 QLogic QLA2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4 See16
Windows 2000 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
15 IBM xSeries x3800/x260 (8865)52 Microsoft PCI−X51 IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
Windows 2000 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000:
Datacenter
SP455, Server
SP4
16 Unisys ES7000/460 [32−Bit] Microsoft PCI, Unisys FCH752313−PCX (LP1050)2, 70, FC−AL, EMC Y3
Windows 2000 PCI−X 72 FC−SW CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000:
Datacenter
SP455, Server
SP4
17 IBM Netfinity: 8500, 8500R; Microsoft PCI IBM 19K1246: (QLA2310)10, 13, 14, 27, 43 , FC−AL, EMC Y3
Windows 2000 (QLA2310)10, 13, 14, 27, 43, 56 FC−SW CLARiiON
IBM xSeries x37061 Datacenter AX150
SP455
18 Unisys: ES7000/520, ES7000/530, ES7000/540, Microsoft PCI Unisys FCH752313−PCX (LP1050)2, 50, FC−AL, EMC Y3
ES7000/550 Windows 2000 68 FC−SW CLARiiON
Datacenter AX150
SP455
19 Unisys ES7000/560 [32−Bit] Microsoft PCI Unisys FCH752313−PCX (LP1050)2, 50, FC−AL, EMC Y3
Windows 2000 69 FC−SW CLARiiON
Datacenter AX150
SP455
20 IBM xSeries x44061 Microsoft PCI−X IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
Windows 2000 FC−SW CLARiiON
Datacenter AX150
SP455
21 IBM xSeries x445 (8870) Microsoft PCI, IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
Windows 2000 PCI−X FC−SW CLARiiON
Datacenter AX150
SP455
22 Dell PowerVault: 750N, 755N23, 770N24, 775N Microsoft PCI Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC N See1
Windows 2000 7, 8, 10, 11 FC−SW CLARiiON
Powered Server AX150
Appliance Kit
SP4 (SAK)
23 Dell PowerVault: 750N, 750N22, 755N22, 23, 755N23, Microsoft PCI Emulex: LP1050−E2, 7, 8, 10, 11 , FC−AL, EMC N See1
770N22, 775N Windows 2000 LP1150−E2, 5, 6, 7, 8 FC−SW CLARiiON
Powered Server AX150
Appliance Kit
SP4 (SAK)

11/02/2006 220 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
24 Dell PowerVault: 750N, 755N23, 770N24, 775N Microsoft PCI QLogic: QLA200−E−SP10, 25, 26, FC−AL, EMC N See16
Windows 2000 QLA210−E−SP6, 14, 25, FC−SW CLARiiON
Powered Server QLA2340−E−SP10, 27, 28, AX150
Appliance Kit QLA2460−E−SP6, 10, 13, 38
SP4 (SAK)
25 Dell PowerEdge 1950 Microsoft PCI QLogic QLA200−E−SP10, 25, 26 FC−AL, EMC N See16
Windows 2000 Express FC−SW CLARiiON
Powered Server AX150
Appliance Kit
SP4 (SAK)
26 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic QLA200−E−SP10, 25, 26 FC−AL, EMC N See16
Windows 2000 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Powered Server PCI−X AX150
Appliance Kit
Intel: SR1500/S5000PAL, SR2500/S5000PAL; SP4 (SAK)
Samsung ZSS132
27 Sun: x4100, x4200 Microsoft PCI−X Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC N See1
Windows 2000 FC−SW CLARiiON
Powered Server AX150
Appliance Kit
SP4 (SAK)
28 Sun: x4100, x4200 Microsoft PCI−X QLogic QLA2460−E−SP6, 10, 13, 38 FC−AL, EMC N See16
Windows 2000 FC−SW CLARiiON
Powered Server AX150
Appliance Kit
SP4 (SAK)
29 IBM xSeries x3800/x260 (8865)52 Microsoft PCI−X51 IBM 19K1246 (QLA2310)10, 13, 14, 27, 43, FC−AL, EMC Y3
Windows 2000: 56 FC−SW CLARiiON
Advanced AX150
Server SP4,
Datacenter
SP455, Server
SP4
30 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, Microsoft PCI Emulex LP101−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
255023, 4300, 4350, 4400, 6100, 6300, 6350, 6400, Windows 2000: FC−SW CLARiiON
6450, 8450; Advanced AX150
Server SP4,
HPQ Proliant: DL32012, DL360(G2)12, DL36012, Server SP4
DL58012, ML350(G2)12, ML35012, ML370(G2)12,
ML37012, ML530(G2)12, ML530(G3)12, ML53012,
ML57012, ML75012;
IBM: Netfinity 4500R, xSeries x225, xSeries x230,
xSeries x232, xSeries x240, xSeries x250, xSeries
x330, xSeries x335, xSeries x340 (4500R), xSeries
x342, xSeries x350 (6000R), xSeries x370
31 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, Microsoft PCI Emulex LP982−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
255023, 4300, 4350, 4400, 6100, 6300, 6350, 6400, Windows 2000: FC−SW CLARiiON
6450, 8450; Advanced AX150
Server SP4,
HPQ Proliant: DL32012, DL360(G2)12, DL36012, Server SP4
DL58012, ML350(G2)12, ML35012, ML370(G2)12,
ML37012, ML530(G2)12, ML530(G3)12, ML53012,
ML57012, ML75012;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335,
x342, x350 (6000R), x370
32 Fuji Serv (ICL) Trimetra Nova; Microsoft PCI Emulex: LP1050−E2, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
HPQ Proliant: 6000R, DL380(G3)12, DL580(G2)12; Windows 2000: LP1150−E2, 5, 6, 7, 8 FC−SW CLARiiON
Advanced AX150
IBM xSeries x345 (8670)61 Server SP4,
Server SP4
33 Fujitsu Siemens Primergy: BX60076, BX620 S2F64, Microsoft PCI Fujitsu Siemens BX600−FC22Q6, 10, 13, FC−AL, EMC Y3
BX620 S264, BX62064, BX66064 Windows 2000: 14, 27, 63 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
34 IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 Microsoft PCI IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
M20, 5600, 7000 M1060, 7100, 7600; Windows 2000: FC−SW CLARiiON
Advanced AX150
IBM xSeries: x225, x230, x23261, x24061, x25061, Server SP4,
x33061, x335, x340 (4500R)61, x34261, x345 (8670)61, Server SP4
x350 (6000R)61, x37061
35 IBM Netfinity: 6000R, 8500, 8500R; Microsoft PCI IBM 19K1246 (QLA2310)10, 13, 14, 27, 43, FC−AL, EMC Y3
Windows 2000: 56 FC−SW CLARiiON
IBM xSeries x25561 Advanced AX150
Server SP4,
Server SP4
36 IBM: Netfinity 4500R, xSeries x225, xSeries x230, Microsoft PCI IBM: 39M5894 (QLA2460)6, 10, 38, 62 , FC−AL, EMC Y3, 4 See16
xSeries x232, xSeries x240, xSeries x250, xSeries Windows 2000: 39M5895 (QLA2462)6, 10, 38, 62 FC−SW CLARiiON
x330, xSeries x335, xSeries x340 (4500R), xSeries Advanced AX150
x342, xSeries x350 (6000R), xSeries x370 Server SP4,
Server SP4
37 HPQ Proliant: DL32012, DL360(G2)12, DL36012, Microsoft PCI QLogic: QLA200−E−SP10, 13, 14, 25 , FC−AL, EMC Y3, 4 See16
DL58012, ML350(G2)12, ML35012, ML370(G2)12, Windows 2000: QLA210−E−SP6, 25, 57, FC−SW CLARiiON
ML37012, ML530(G2)12, ML530(G3)12, ML53012, Advanced QLA2340−E−SP10, 13, 14, 27 , AX150
ML57012, ML75012; Server SP4, QLA2460−E−SP6, 10, 13, 14, 38
Server SP4
IBM: Netfinity 4500R, xSeries x225, xSeries x230,
xSeries x232, xSeries x240, xSeries x250, xSeries
x330, xSeries x335, xSeries x340 (4500R), xSeries
x342, xSeries x350 (6000R), xSeries x370

11/02/2006 221 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
38 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, Microsoft PCI QLogic: QLA200−E−SP10, 25, 26, FC−AL, EMC Y3, 4 See16
255023, 4300, 4350, 4400, 6100, 6300, 6350, 6400, Windows 2000: QLA210−E−SP6, 14, 25, FC−SW CLARiiON
6450, 8450 Advanced QLA2340−E−SP10, 27, 28, AX150
Server SP4, QLA2460−E−SP6, 10, 13, 38
Server SP4
39 Unisys: ES3120, ES3120L, ES3140, ES3140L Microsoft PCI Unisys FCH752313−PCX (LP1050)2, 50, FC−AL, EMC Y3
Windows 2000: 70 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
40 Samsung: ZSS230, ZSS230D Microsoft PCI Emulex LP101−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
41 Dell PowerEdge 1950; Microsoft PCI Emulex LP982−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Samsung: ZSS230, ZSS230D Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
42 HPQ Proliant: BL460c (404664−B21), BL465c Microsoft PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
(403433−B21), BL465c (403434−B21), BL465c Windows 2000: Express for HP c−Class Bladesystem FC−SW CLARiiON
(407234−B21), BL465c (407235−B21), BL480c Advanced (403621−B21)2, 32, 36, QLogic QMH2462 AX150
(404704−B21) Server SP4, 4Gb FC HBA for HP c−Class
Server SP4 Bladesystem (403619−B21)53, 54
43 Dell PowerEdge 1950 Microsoft PCI QLogic QLA200−E−SP10, 13, 14, 25 FC−AL, EMC Y3, 4, 41 See16
Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
44 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y3, 4 See16
Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
45 Dell PowerEdge 1950 Microsoft PCI QLogic: QLA200−E−SP10, 13, 14, 25 , FC−AL, EMC Y3, 4 See16
Windows 2000: Express QLA200−E−SP10, 25, 26, QLA210−E−SP6, FC−SW CLARiiON
Advanced 14, 25, QLA2340−E−SP10, 27, 28 AX150
Server SP4,
Server SP4
46 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic: QLA2340−E−SP10, 13, 14, 27 , FC−AL, EMC Y3, 4, 17 See16
Windows 2000: Express QLA2460−E−SP6, 10, 13, 14, 38 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
47 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI QLogic: QLE220−E−SP6, 10, 39, 40 , FC−AL, EMC Y3, 4, 17 See16
Windows 2000: Express QLE2360−E−SP10, 13, 14, 15 , FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Advanced QLE2460−E−SP6, 10, 13, 14, 38 AX150
Server SP4,
LangChao: NC3000, NC3500, NF500, NF520; Server SP4
Samsung: ZSS150, ZSS230, ZSS230D
48 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI QLogic: QLE220−E−SP6, 10, 39, 40 , FC−AL, EMC Y3, 4, See16
Windows 2000: Express QLE2360−E−SP10, 13, 14, 15 , FC−SW CLARiiON Y3, 4, 41
LangChao: NC3000, NC3500, NF500, NF520; Advanced QLE2460−E−SP6, 10, 13, 14, 38 AX150
Server SP4,
Samsung: ZSS230, ZSS230D Server SP4
49 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Microsoft PCI QLogic: QLE220−E−SP6, 10, 40, 46 , FC−AL, EMC Y3, 4 See16
6850 Windows 2000: Express QLE2360−E−SP10, 15, 28, FC−SW CLARiiON
Advanced QLE2460−E−SP6, 10, 28, 38 AX150
Server SP4,
Server SP4
50 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex LP101−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)44, x346 (8840)44; Advanced PCI−X AX150
Server SP4,
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Server SP4
SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
51 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI Emulex LP982−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Advanced PCI−X AX150
Server SP4,
Digital Henge Revo: AS1500, AS1550, AS2500; Server SP4
IBM xSeries: x336 (8837)44, x346 (8840)44;
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2,
SR1500/S5000PAL, SR2400/SE7520JR2,
SR2500/S5000PAL, SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
Samsung ZSS132
52 HPQ Proliant ML350(G4)12 Microsoft PCI HPQ: AB429A/FC1143 (QLA2460)6, 10, FC−AL, EMC Y3, 4 See16
Windows 2000: Express, 14, 38, AE369A/FC1243 (QLA2462)6, 10, FC−SW CLARiiON
Advanced PCI−X 14, 38 AX150
Server SP4,
Server SP4

11/02/2006 222 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
53 IBM xSeries x346 (8840)44 Microsoft PCI IBM 24P0960 (QLA2340)10, 13, 14, 27, 59 FC−AL, EMC Y
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP4,
Server SP4
54 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic QLA200−E−SP10, 13, 14, 25 FC−AL, EMC Y3, 4 See16
Windows 2000: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Advanced PCI−X AX150
Server SP4,
IBM xSeries: x336 (8837)44, x346 (8840)44; Server SP4
Intel: SR1500/S5000PAL, SR2500/S5000PAL;
Samsung ZSS132
55 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic QLA200−E−SP10, 13, 14, 25 FC−AL, EMC Y3, 4, 41 See16
Windows 2000: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Advanced PCI−X AX150
Server SP4,
Intel: SR1500/S5000PAL, SR2500/S5000PAL; Server SP4
Samsung ZSS132
56 IBM xSeries: x336 (8837)44, x346 (8840)44 Microsoft PCI QLogic QLA210−E−SP6, 25, 57 FC−AL, EMC Y3, 4 See16
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP4,
Server SP4
57 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y3, 4 See16
Windows 2000: Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)44, x346 (8840)44; Advanced PCI−X AX150
Server SP4,
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Server SP4
SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
58 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI QLogic: QLA200−E−SP10, 25, 26, FC−AL, EMC Y3, 4 See16
Windows 2000: Express, QLA210−E−SP6, 14, 25, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; Advanced PCI−X QLA2340−E−SP10, 27, 28, AX150
Server SP4, QLE220−E−SP6, 10, 40, 46 ,
Intel: SR1500/S5000PAL, SR2500/S5000PAL; Server SP4 QLE2360−E−SP10, 15, 28,
QLE2460−E−SP6, 10, 28, 38
Samsung ZSS132
59 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic: QLA2340−E−SP10, 13, 14, 27 , FC−AL, EMC Y3, 4, 17 See16
Windows 2000: Express, QLA2460−E−SP6, 10, 13, 14, 38 , FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X QLE220−E−SP6, 10, 39, 40 , AX150
SR2400/SE7520JR2, Server SP4, QLE2360−E−SP10, 13, 14, 15 ,
SR4850HW4−M/SR6850HW4−M, Server SP4 QLE2460−E−SP6, 10, 13, 14, 38
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
60 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic: QLE220−E−SP6, 10, 39, 40 , FC−AL, EMC Y3, 4, See16
Windows 2000: Express, QLE2360−E−SP10, 13, 14, 15 , FC−SW CLARiiON Y3, 4, 41
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X QLE2460−E−SP6, 10, 13, 14, 38 AX150
SR4850HW4/SR6850HW4; Server SP4,
Server SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
61 Dell PowerEdge 6850 Microsoft PCI−X Dell 2362M10, 14, 45, 49 FC−AL, EMC Y3
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
62 Dell PowerEdge 1855 Microsoft PCI−X Dell: 2342M10, 14, 27, LPe1105−M2, 6, 32, FC−AL, EMC Y3
Windows 2000: 42, QME24626, 14, 45 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
63 Fujitsu Siemens Primergy: RX200 S2, RX300 S2, Microsoft PCI−X Emulex LP101−E2, 7, 8, 10, 50 FC−AL, EMC Y3, 4 See1
TX200 S2, TX300 S2 Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
64 Dell PowerEdge 265077; Microsoft PCI−X Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Digital Henge INNO: HR−4850, HR−6850; Windows 2000: FC−SW CLARiiON
Advanced AX150
LangChao: NC3000, NC3500, NF500, NF520; Server SP4,
Server SP4
Samsung ZSS150
65 Dell PowerEdge 265077; Microsoft PCI−X Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
Digital Henge INNO: HR−4850, HR−6850; Windows 2000: FC−SW CLARiiON
Advanced AX150
LangChao: NC3000, NC3500, NF500, NF520; Server SP4,
Server SP4
Samsung ZSS150;
Sun: x4100, x4200

11/02/2006 223 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
66 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, Microsoft PCI−X Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC Y3, 4 See1
2800, 2850, 4600, 6600, 6650, 6800, 6850; Windows 2000: 7, 8, 10, 11 FC−SW CLARiiON
Advanced AX150
Digital Henge INNO: HR−4850, HR−6850, SH4500; Server SP4,
Server SP4
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12,
DL56012, DL74012, DL760 (G2)12, DL76012,
ML570(G2)12;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
67 IBM xSeries x3850/x366 (8863)52 Microsoft PCI−X Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC Y3, 4, 41 See1
Windows 2000: 7, 8, 10, 11 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
68 Fujitsu Siemens Primergy: RX300 S2, TX300 S2 Microsoft PCI−X Emulex: LP1050Ex−E2, 6, 7, 8, 10, 50 , FC−AL, EMC Y4, Y4, See1
Windows 2000: LP1050Ex−E2, 6, 8, 10, 32, 50 FC−SW CLARiiON 17
Advanced AX150
Server SP4,
Server SP4
69 HPQ Proliant DL360(G4)12 Microsoft PCI−X HPQ AE311A/FC1142SR (QLE2460)6, 10, FC−AL, EMC Y3, Y3,
Windows 2000: 13, 14, 38 FC−SW CLARiiON 17, Y3,
Advanced AX150 41
Server SP4,
Server SP4
70 HPQ Proliant DL360(G4)12 Microsoft PCI−X HPQ: AB429A/FC1143 (QLA2460)6, 10, FC−AL, EMC Y3, 4 See16
Windows 2000: 14, 38, AE369A/FC1243 (QLA2462)6, 10, FC−SW CLARiiON
Advanced 14, 38; AX150
Server SP4,
Server SP4 QLogic: QLE220−E−SP6, 10, 39, 40 ,
QLE2360−E−SP10, 13, 14, 15 ,
QLE2460−E−SP6, 10, 13, 14, 38
71 HPQ Proliant BL460c: (416653−B21), (416654−B21), Microsoft PCI−X HPQ: Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
(416655−B21), (416656−B21), (432636−B21); Windows 2000: for HP c−Class Bladesystem FC−SW CLARiiON
Advanced (403621−B21)2, 32, 36, QLogic QMH2462 AX150
HPQ Proliant BL480c: (416666−B21), (416667−B21), Server SP4, 4Gb FC HBA for HP c−Class
(416668−B21), (416669−B21) Server SP4 Bladesystem (403619−B21)53, 54
72 IBM xSeries: x235, x255, x360, x365, x440 Microsoft PCI−X IBM: 39M5894 (QLA2460)6, 10, 38, 62 , FC−AL, EMC Y3, 4 See16
Windows 2000: 39M5895 (QLA2462)6, 10, 38, 62 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
73 NEC Express 5800: 110Rg−1, 120Rf−1, 120Rh−2 Microsoft PCI−X NEC N8190−120 (LP1050)2, 7, 8, 10, 11, 75 FC−AL, EMC Y
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
74 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y3, 4, 17 See16
Windows 2000: FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; Advanced AX150
Server SP4,
Samsung ZSS150 Server SP4
75 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4, 17 See16
Windows 2000: FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; Advanced AX150
Server SP4,
Samsung ZSS150; Server SP4
Sun: x4100, x4200
76 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, Microsoft PCI−X QLogic QLA2460−E−SP6, 10, 13, 38 FC−AL, EMC Y3, 4 See16
4600, 6600, 6650; Windows 2000: FC−SW CLARiiON
Advanced AX150
Sun: x4100, x4200 Server SP4,
Server SP4
77 Digital Henge INNO SH4500; Microsoft PCI−X QLogic: QLA200−E−SP10, 13, 14, 25 , FC−AL, EMC Y3, 4 See16
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12, Windows 2000: QLA210−E−SP6, 25, 57 FC−SW CLARiiON
DL56012, DL74012, DL760 (G2)12, DL76012, Advanced AX150
ML570(G2)12; Server SP4,
Server SP4
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun: V20z, V40z, x4100, x4200
78 IBM xSeries x3850/x366 (8863)52 Microsoft PCI−X QLogic: QLA200−E−SP10, 13, 14, 25 , FC−AL, EMC Y3, 4, 41 See16
Windows 2000: QLA210−E−SP6, 25, 57, FC−SW CLARiiON
Advanced QLA2340−E−SP10, 13, 14, 27 AX150
Server SP4,
Server SP4

11/02/2006 224 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
79 Dell PowerEdge: 1600SC, 1650, 1750, 2600, 2650, Microsoft PCI−X QLogic: QLA200−E−SP10, 25, 26, FC−AL, EMC Y3, 4 See16
2800, 2850, 4600, 6600, 6650, 6800, 6850 Windows 2000: QLA210−E−SP6, 14, 25, FC−SW CLARiiON
Advanced QLA2340−E−SP10, 27, 28 AX150
Server SP4,
Server SP4
80 Digital Henge INNO: HR−4850, HR−6850, SH4500; Microsoft PCI−X QLogic: QLA2340−E−SP10, 13, 14, 27 , FC−AL, EMC Y3, 4 See16
Windows 2000: QLA2460−E−SP6, 10, 13, 14, 38 FC−SW CLARiiON
Digital Henge SH4500R4; Advanced AX150
HPQ Proliant: DL360(G3)12, DL360(G4)12, DL56012, Server SP4,
DL74012, DL760 (G2)12, DL76012, ML570(G2)12; Server SP4
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
81 HPQ Proliant DL360(G4)12 Microsoft PCI−X QLogic: QLE220−E−SP6, 10, 39, 40 , FC−AL, EMC Y3, 4, 17, See16
Windows 2000: QLE2360−E−SP10, 13, 14, 15 , FC−SW CLARiiON Y3, 4, 41
Advanced QLE2460−E−SP6, 10, 13, 14, 38 AX150
Server SP4,
Server SP4
82 IBM xSeries x3800/x260 (8865)52 Microsoft PCI−X51 Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4, 41 See1
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
83 IBM xSeries x3800/x260 (8865)52 Microsoft PCI−X51 Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC Y3, 4 See1
Windows 2000: 7, 8, 10, 11 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
84 IBM xSeries: x3800/x260 (8865)52, x3950/x3950E/x460 Microsoft PCI−X51 Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC Y3, 4, 41 See1
(8872, 8874)52 Windows 2000: 7, 8, 10, 11 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
85 IBM xSeries x3950/x3950E/x460 (8872, 8874)52 Microsoft PCI−X51 Emulex: LP101−E2, 8, 10, 11, 32 , FC−AL, EMC Y4 See1
Windows 2000: LP1050−E2, 7, 8, 10, 11 , LP982−E2, 7, 8, 10, FC−SW CLARiiON
Advanced 11 AX150
Server SP4,
Server SP4
86 IBM xSeries x3950/x3950E/x460 (8872, 8874)52 Microsoft PCI−X51 IBM: 19K1246 (QLA2310)10, 13, 14, 27, 43 , FC−AL, EMC Y
Windows 2000: 24P0960 (QLA2340)10, 13, 14, 27, 59 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
87 IBM xSeries x3800/x260 (8865)52 Microsoft PCI−X51 QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y3, 4 See16
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
88 IBM xSeries x3950/x3950E/x460 (8872, 8874)52 Microsoft PCI−X51 QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y4 See16
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
89 IBM xSeries: x3800/x260 (8865)52, x3950/x3950E/x460 Microsoft PCI−X51 QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y3, 4, 41 See16
(8872, 8874)52 Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
90 IBM xSeries x3950/x3950E/x460 (8872, 8874)52 Microsoft PCI−X51 QLogic: QLA200−E−SP10, 13, 14, 25 , FC−AL, EMC Y3, 4, 41 See16
Windows 2000: QLA210−E−SP6, 25, 57 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
91 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC Y3, 4 See1
Windows 2000: 7, 8, 10, 11 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
92 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 QLogic QLA2340−E−SP10, 13, 14, 27 FC−AL, EMC Y3, 4 See16
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
93 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 QLogic: QLA2340−E−SP10, 13, 14, 27 , FC−AL, EMC Y3, 4, 17 See16
Windows 2000: QLA2460−E−SP6, 10, 13, 14, 38 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
94 Dell PowerEdge 1955 Microsoft PCI, PCI Dell: 2342M10, 14, 27, LPe1105−M2, 6, 32, FC−AL, EMC Y3
Windows 2000: Express, 42, QME24626, 14, 45 FC−SW CLARiiON
Advanced PCI−X AX150
Server SP4,
Server SP4

11/02/2006 225 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
95 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI HPQ: AB429A/FC1143 (QLA2460)6, 10, FC−AL, EMC Y3, 4 See16
Windows 2000: Express, 14, 38, AE369A/FC1243 (QLA2462)6, 10, FC−SW CLARiiON
Advanced PCI−X 14, 38; AX150
Server SP4,
Server SP4 QLogic QLA2460−E−SP6, 10, 13, 14, 38
96 HPQ Proliant DL580(G3)12 Microsoft PCI, PCI QLogic QLE220−E−SP6, 10, 39, 40 FC−AL, EMC Y3, 4 See16
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP4,
Server SP4
97 HPQ Proliant: DL380(G4)12, DL580(G3)12 Microsoft PCI, PCI QLogic QLE2360−E−SP10, 13, 14, 15 FC−AL, EMC Y3, 4 See16
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP4,
Server SP4
98 HPQ Proliant: DL380(G4)12, DL380(G5), DL580(G3)12, Microsoft PCI, PCI QLogic QLE2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4 See16
DL580(G4) Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP4,
Server SP4
99 HPQ Proliant: DL380(G5), DL580(G3)12, DL580(G4) Microsoft PCI, PCI QLogic QLE2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4, 17, See16
Windows 2000: Express, FC−SW CLARiiON Y3, 4, 41
Advanced PCI−X AX150
Server SP4,
Server SP4
100 HPQ Proliant DL580(G3)12 Microsoft PCI, PCI QLogic: QLE220−E−SP6, 10, 39, 40 , FC−AL, EMC Y3, 4, 17, See16
Windows 2000: Express, QLE2360−E−SP10, 13, 14, 15 FC−SW CLARiiON Y3, 4, 41
Advanced PCI−X AX150
Server SP4,
Server SP4
101 Dell PowerEdge: 1800, 1850; Microsoft PCI, Emulex: LP101−E2, 7, 8, 10, 11 , LP982−E2, FC−AL, EMC Y3, 4 See1
Windows 2000: PCI−X 7, 8, 10, 11 FC−SW CLARiiON
HPQ Proliant: DL14512, DL380(G2)12, DL380(G3)12, Advanced AX150
DL380(G4)12, DL38012, DL38512, DL580(G2)12, Server SP4,
DL580(G3)12, DL58512, ML350(G3)12, ML370(G3)12, Server SP4
ML370(G4)12;
IBM: eServer 325 (Model 8835), xSeries x345 (8670),
xSeries x445 (8870);
Samsung SS140
102 IBM xSeries x36061 Microsoft PCI, Emulex: LP1050−E2, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
Windows 2000: PCI−X LP1150−E2, 5, 6, 7, 8 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
103 HPQ Proliant: DL380(G4)12, DL38512, DL58512, Microsoft PCI, HPQ: AB429A/FC1143 (QLA2460)6, 10, FC−AL, EMC Y3, 4 See16
ML370(G4)12 Windows 2000: PCI−X 14, 38, AE369A/FC1243 (QLA2462)6, 10, FC−SW CLARiiON
Advanced 14, 38 AX150
Server SP4,
Server SP4
104 IBM: eServer 325 (Model 8835), xSeries x445 (8870) Microsoft PCI, IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
Windows 2000: PCI−X FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
105 IBM: eServer 325 (Model 8835), xSeries x345 (8670), Microsoft PCI, IBM: 39M5894 (QLA2460)6, 10, 38, 62 , FC−AL, EMC Y3, 4 See16
xSeries x445 (8870) Windows 2000: PCI−X 39M5895 (QLA2462)6, 10, 38, 62 FC−SW CLARiiON
Advanced AX150
Server SP4,
Server SP4
106 HPQ Proliant: DL14512, DL380(G2)12, DL380(G3)12, Microsoft PCI, QLogic: QLA200−E−SP10, 13, 14, 25 , FC−AL, EMC Y3, 4 See16
DL380(G4)12, DL38012, DL38512, DL580(G2)12, Windows 2000: PCI−X QLA210−E−SP6, 25, 57, FC−SW CLARiiON
DL580(G3)12, DL58512, ML350(G3)12, ML370(G3)12, Advanced QLA2340−E−SP10, 13, 14, 27 , AX150
ML370(G4)12; Server SP4, QLA2460−E−SP6, 10, 13, 14, 38
Server SP4
IBM: eServer 325 (Model 8835), xSeries x345 (8670),
xSeries x445 (8870);
Samsung SS140
107 Dell PowerEdge: 1800, 1850 Microsoft PCI, QLogic: QLA200−E−SP10, 25, 26, FC−AL, EMC Y3, 4 See16
Windows 2000: PCI−X QLA210−E−SP6, 14, 25, FC−SW CLARiiON
Advanced QLA2340−E−SP10, 27, 28 AX150
Server SP4,
Server SP4
108 Dell PowerEdge: 155077, 165077, 2300, 240077, Microsoft PCI Emulex: LP1050−E2, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
245077, 250077, 255023, 77, 440077, 6100, 6300, 6350, Windows 2000: LP1150−E2, 5, 6, 7, 8 FC−SW CLARiiON
640077, 645077, 78, 845077; Advanced AX150
Server SP49,
HPQ Netserver LC: 2000 U3, 2000r; Server SP4
HPQ Netserver: LP 2000r, LPR, LT 6000R;
HPQ Proliant: 160012, 185012, 6400R, 800012, 850012,
DL32012, DL360(G2)12, 80, DL36012, DL380(G2)12,
DL380(G3)12, DL38012, DL58012, ML350(G2)12, 79,
ML35012, 79, ML370(G2)12, ML37012, ML530(G2)12,
ML530(G3)12, ML53012, ML57012, ML75012;
IBM Netfinity: 4500R, 8500, 8500R;
IBM xSeries: x225, x230, x23261, x24061, x25061,
x25561, x33061, x335, x340 (4500R)61, x34261, x350
(6000R)61, x37061

11/02/2006 226 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
109 IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 Microsoft PCI IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
M20, 5600, 6000R, 7000 M1060, 7100, 7600, 8500, Windows 2000: FC−SW CLARiiON
8500R; Advanced AX150
Server SP49,
IBM xSeries: x225, x230, x23261, x24061, x25061, Server SP4
x25561, x33061, x335, x340 (4500R)61, x34261, x350
(6000R)61, x37061
110 NEC Express 5800: 320La−R83, 320La83, 320Lb−R83, Microsoft PCI NEC N8803−031 (QLA2310F)10, 13, 14, FC−AL, EMC N
87, 320Lb83, 87, 330Ma−R83, 330Mb−R82, 83, 84 , Windows 2000: 27, 85, 86 FC−SW CLARiiON
340Ha−R82, 83, 84 Advanced AX150
Server SP49,
Server SP4
111 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Microsoft PCI Emulex LP1050Ex−E2, 6, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
6850; Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Digital Henge INNO: HR−4850, HR−6850; Server SP49,
Server SP4
HPQ Proliant: DL360(G4)12, DL380(G4)12,
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS230, ZSS230D
112 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI Emulex LP1050Ex−E2, 6, 7, 8, 10, 11 FC−AL, EMC Y3, 4, 17 See1
Windows 2000: Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Advanced AX150
Server SP49,
HPQ Proliant: DL360(G4)12, DL380(G4)12, Server SP4
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS150, ZSS230, ZSS230D
113 Fujitsu Siemens Primergy: RX200 S2, RX600 S2, Microsoft PCI Emulex LP1050Ex−E2, 6, 7, 8, 10, 50 FC−AL, EMC Y3, 4, See1
TX600 S2 Windows 2000: Express FC−SW CLARiiON Y3, 4, 17
Advanced AX150
Server SP49,
Server SP4
114 Samsung: ZSS230, ZSS230D Microsoft PCI Emulex LP982−E2, 6, 7, 8, 10, 11, 18 FC−AL, EMC Y3, 4 See1
Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
115 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Microsoft PCI Emulex: LPe111−E2, 6, 10, 35, 36, 37 , FC−AL, EMC Y3, 4 See1
6850; Windows 2000: Express LPe1150−E2, 6, 7, 8, 42 FC−SW CLARiiON
Advanced AX150
Digital Henge INNO: HR−4850, HR−6850; Server SP49,
Server SP4
HPQ Proliant: DL360(G4)12, 47, DL380(G4)12,
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS230, ZSS230D
116 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI Emulex: LPe111−E2, 6, 10, 35, 36, 37 , FC−AL, EMC Y3, 4, 17 See1
Windows 2000: Express LPe1150−E2, 6, 7, 8, 42 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Advanced AX150
Server SP49,
HPQ Proliant: DL360(G4)12, 47, DL380(G4)12, Server SP4
DL580(G3)12;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: ZSS150, ZSS230, ZSS230D
117 HPQ Proliant DL360(G4)12 Microsoft PCI HPQ A7560A (LP1050Ex)2, 6, 7, 8, 10 FC−AL, EMC Y3, Y3,
Windows 2000: Express FC−SW CLARiiON 17
Advanced AX150
Server SP49,
Server SP4
118 HPQ Proliant: DL360(G4)12, 47, DL380(G4)12, Microsoft PCI HPQ A8002A/FC2142SR (LPe1150)2, 6, FC−AL, EMC Y3, Y3,
DL580(G3)12 Windows 2000: Express 7, 8, 42 FC−SW CLARiiON 17
Advanced AX150
Server SP49,
Server SP4
119 HPQ Proliant: DL360(G4)12, DL360(G4)12, 47, Microsoft PCI HPQ AE311A/FC1142SR (QLE2460)6, 10, FC−AL, EMC Y3, Y3,
DL380(G4)12 Windows 2000: Express 13, 14, 38 FC−SW CLARiiON 17
Advanced AX150
Server SP49,
Server SP4
120 Samsung: ZSS230, ZSS230D Microsoft PCI QLogic QLA2340−E−SP10, 13, 14, 27, 48 FC−AL, EMC Y3, 4 See16
Windows 2000: Express FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
121 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex LP982−E2, 6, 7, 8, 10, 11, 18 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X AX150
SR2400/SE7520JR2, Server SP49,
SR4850HW4−M/SR6850HW4−M, Server SP4
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650

11/02/2006 227 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
122 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft PCI Emulex: LP1050Ex−E2, 6, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
Windows 2000: Express, LPe111−E2, 6, 10, 35, 36, 37 , LPe1150−E2, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Advanced PCI−X 6, 7, 8, 42 AX150
Server SP49,
Digital Henge Revo: AS1500, AS1550, AS2500; Server SP4
Intel: SR1500/S5000PAL, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650;
Samsung ZSS132
123 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Emulex: LP1050Ex−E2, 6, 7, 8, 10, 11 , FC−AL, EMC Y3, 4, 17 See1
Windows 2000: Express, LPe111−E2, 6, 10, 35, 36, 37 , LPe1150−E2, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X 6, 7, 8, 42 AX150
SR2400/SE7520JR2, Server SP49,
SR4850HW4−M/SR6850HW4−M, Server SP4
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
124 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI QLogic QLA2340−E−SP10, 13, 14, 27, 48 FC−AL, EMC Y3, 4 See16
Windows 2000: Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, SR1400/SE7520JR2, Advanced PCI−X AX150
SR2400/SE7520JR2, Server SP49,
SR4850HW4−M/SR6850HW4−M, Server SP4
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
125 Dell PowerEdge: 1600SC, 1750, 260077, 2650, 2800, Microsoft PCI−X Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
2850, 460077, 660077, 665077, 6800, 6850; Windows 2000: FC−SW CLARiiON
Advanced AX150
Digital Henge INNO: HR−4850, HR−6850, SH4500; Server SP49,
Server SP4
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12,
DL56012, DL74012, DL760 (G2)12, DL76012,
ML570(G2)12;
IBM xSeries: x23561, x36061, x365, x440, x44061;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
126 IBM xSeries x3850/x366 (8863)52 Microsoft PCI−X Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4, 41 See1
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
127 HPQ Proliant DL360(G4)12 Microsoft PCI−X Emulex LP1050Ex−E2, 6, 7, 8, 10, 11 FC−AL, EMC Y3, 4, See1
Windows 2000: FC−SW CLARiiON Y3, 4, 17
Advanced AX150
Server SP49,
Server SP4
128 Dell PowerEdge: 1600SC, 1750, 260077, 2650, 460077, Microsoft PCI−X Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
660077, 665077; Windows 2000: FC−SW CLARiiON
Advanced AX150
Digital Henge INNO: HR−4850, HR−6850, SH4500; Server SP49,
Server SP4
HPQ Proliant: BL40p, DL360(G3)12, DL360(G4)12, 47,
DL56012, DL74012, DL760 (G2)12, DL76012,
ML570(G2)12;
IBM xSeries: x23561, x36061, x365, x440, x44061;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo: ShenTeng R630, SureServer R630 6003,
SureServer R630 6004, SureServer T630 6003,
SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370, SS3840,
ZSS150;
Sun: V20z, V40z, x4100, x4200
129 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X Emulex LP982−E2, 6, 7, 8, 10, 11, 18 FC−AL, EMC Y3, 4 See1
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced AX150
LangChao: NC3000, NC3500, NF500, NF520; Server SP49,
Server SP4
Samsung ZSS150
130 HPQ Proliant DL360(G4)12, 47 Microsoft PCI−X Emulex: LPe111−E2, 6, 10, 35, 36, 37 , FC−AL, EMC Y3, 4, See1
Windows 2000: LPe1150−E2, 6, 7, 8, 42 FC−SW CLARiiON Y3, 4, 17
Advanced AX150
Server SP49,
Server SP4
131 HPQ Proliant DL360(G4)12, 47 Microsoft PCI−X HPQ A8002A/FC2142SR (LPe1150)2, 6, FC−AL, EMC Y3, Y3,
Windows 2000: 7, 8, 42 FC−SW CLARiiON 17
Advanced AX150
Server SP49,
Server SP4

11/02/2006 228 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
132 HPQ Proliant: DL360(G4)12, DL360(G4)12, 47 Microsoft PCI−X HPQ AE311A/FC1142SR (QLE2460)6, 10, FC−AL, EMC Y3, Y3,
Windows 2000: 13, 14, 38 FC−SW CLARiiON 17
Advanced AX150
Server SP49,
Server SP4
133 HPQ Proliant BL45p Microsoft PCI−X HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y3
Windows 2000: for HP Proliant BL25p/BL45p FC−SW CLARiiON
Advanced 381881−B216, 10, 13, 14, 73 , AX150
Server SP49, Emulex−based BL25/30/35/45p Fibre
Server SP4 Channel Mezzanine HBA −
394588−B212, 7, 8, 10, 65
134 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2340−E−SP10, 13, 14, 27, 48 FC−AL, EMC Y3, 4 See16
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced AX150
LangChao: NC3000, NC3500, NF500, NF520; Server SP49,
Server SP4
Samsung ZSS150
135 Digital Henge INNO: HR−4850, HR−6850; Microsoft PCI−X QLogic QLA2460−E−SP6, 10, 13, 14, 38 FC−AL, EMC Y3, 4 See16
Windows 2000: FC−SW CLARiiON
HPQ Proliant BL40p; Advanced AX150
LangChao: NC3000, NC3500, NF500, NF520; Server SP49,
Server SP4
Samsung ZSS150;
Sun: x4100, x4200
136 HPQ Proliant BL20p (G2) Microsoft PCI−X20 HPQ Dual−port Fibre Channel Adapter for FC−AL, EMC Y3
Windows 2000: HP Proliant BL20p (G2) 300874−B2110, FC−SW CLARiiON
Advanced 13, 14, 21 AX150
Server SP49,
Server SP4
137 HPQ Proliant BL20p: (G3), (G4) Microsoft PCI−X20 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y3
Windows 2000: for HP Proliant BL20p (G3) FC−SW CLARiiON
Advanced 361426−B2110, 13, 14, 21 , Emulex−based AX150
Server SP49, BL20p (G3) Fibre Channel Mezzanine
Server SP4 HBA − 394757−B212, 7, 8, 10, 65
138 HPQ Proliant BL25p Microsoft PCI−X20 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y3
Windows 2000: for HP Proliant BL25p/BL45p FC−SW CLARiiON
Advanced 381881−B216, 10, 13, 14, 73 , AX150
Server SP49, Emulex−based BL25/30/35/45p Fibre
Server SP4 Channel Mezzanine HBA −
394588−B212, 7, 8, 10, 65
139 HPQ Proliant BL30p Microsoft PCI−X20 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y3, 19
Windows 2000: for HP Proliant BL30p/BL35p FC−SW CLARiiON
Advanced 354054−B2110, 13, 14, 21 , Emulex−based AX150
Server SP49, BL25/30/35/45p Fibre Channel
Server SP4 Mezzanine HBA − 394588−B212, 7, 8, 10,
65

140 IBM xSeries: x3800/x260 (8865)52, x3950/x3950E/x460 Microsoft PCI−X51 Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4, 41 See1
(8872, 8874)52 Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
141 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 Emulex LP982−E2, 6, 7, 8, 10, 11, 18 FC−AL, EMC Y3, 4 See1
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
142 Digital Henge Revo: JS1400, JS2400 Microsoft PCI−X74 QLogic QLA2340−E−SP10, 13, 14, 27, 48 FC−AL, EMC Y3, 4 See16
Windows 2000: FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
143 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
144 HPQ Proliant: DL380(G4)12, DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LPe1150−E2, 6, 7, 8, 42 FC−AL, EMC Y3, 4 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
145 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI Emulex LPe1150−E2, 6, 7, 8, 42 FC−AL, EMC Y3, 4, 17 See1
Windows 2000: Express, FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
146 HPQ Proliant DL380(G4)12 Microsoft PCI, PCI Emulex: LP1050Ex−E2, 6, 7, 8, 10, 11 , FC−AL, EMC Y3, 4 See1
Windows 2000: Express, LPe111−E2, 6, 10, 35, 36, 37 FC−SW CLARiiON
Advanced PCI−X AX150
Server SP49,
Server SP4
147 HPQ Proliant: DL380(G5), DL580(G4) Microsoft PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)2, 6, FC−AL, EMC Y3, Y3,
Windows 2000: Express, 7, 8, 42, AE311A/FC1142SR (QLE2460)6, FC−SW CLARiiON 17
Advanced PCI−X 10, 13, 14, 38 AX150
Server SP49,
Server SP4
148 Dell PowerEdge: 1800, 1850; Microsoft PCI, Emulex LP1050−E2, 7, 8, 10, 11 FC−AL, EMC Y3, 4 See1
Windows 2000: PCI−X FC−SW CLARiiON
HPQ Proliant: DL14512, DL380(G4)12, DL38512, Advanced AX150
DL580(G2)12, DL580(G3)12, DL58512, ML350(G3)12, Server SP49,
ML370(G3)12, ML370(G4)12; Server SP4
IBM: eServer 325 (Model 8835), xSeries x345 (8670)61,
xSeries x445 (8870);
Samsung SS140

11/02/2006 229 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
149 HPQ Proliant: DL14512, DL380(G4)12, DL38512, Microsoft PCI, Emulex LP1150−E2, 5, 6, 7, 8 FC−AL, EMC Y3, 4 See1
DL580(G2)12, DL580(G3)12, DL58512, ML350(G3)12, Windows 2000: PCI−X FC−SW CLARiiON
ML370(G3)12, ML370(G4)12; Advanced AX150
Server SP49,
IBM: eServer 325 (Model 8835), xSeries x345 (8670)61, Server SP4
xSeries x445 (8870);
Samsung SS140
150 IBM: eServer 325 (Model 8835), xSeries x345 (8670)61, Microsoft PCI, IBM 19K1246 (QLA2310)10, 13, 14, 27, 43 FC−AL, EMC Y3
xSeries x445 (8870) Windows 2000: PCI−X FC−SW CLARiiON
Advanced AX150
Server SP49,
Server SP4
151 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4 See1
Windows 2000 Express AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
152 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4 See16
Windows 2000 Express AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
153 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See1
Windows 2000 Express, Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX150
SR4850HW4/SR6850HW4; Server: SP4,
SP49;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
Microsoft
Windows 2000
Server SP4
154 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See16
Windows 2000 Express, Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX150
SR4850HW4/SR6850HW4; Server: SP4,
SP49;
Lenovo SureServer: R630 G5, R650, R650 G5, T650
Microsoft
Windows 2000
Server SP4
155 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See1
Windows 2000 Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
156 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4 See16
Windows 2000 Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
157 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft PCI−X IBM Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y31 See29
Windows 2000 Card (39Y9186)5, 6, 32, 33 CLARiiON
IBM BladeCenter LS20 (Model 8850) Advanced AX150
Server: SP4,
SP49;
Microsoft
Windows 2000
Server SP4
158 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See16
Windows 2000: Express Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON Y3, 4, 17,
Advanced AX150 Y3, 4, 41
Server SP4,
Server SP4
159 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, 17, See16
Windows 2000: Express AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON Y3, 4, 41
Advanced AX150
Server SP4,
Server SP4
160 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, 17, See16
Windows 2000: Express, Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON Y3, 4, 41
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX150
SR4850HW4/SR6850HW4; Server SP4,
Server SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
161 Bull NovaScale: 2021, 2040, 2320 Microsoft PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
Windows 2000: port for NovaScale Blade Series CLARiiON
Advanced CFSN202−110010, 13, 14, 34 AX150
Server SP4,
Server SP4

11/02/2006 230 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot Comments
162 Bull NovaScale: 2021, 2320 Microsoft PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
Windows 2000: port mini for NovaScale Blade 2021 CLARiiON
Advanced CFSN202−210010, 13, 14, 34 , SBEFCM AX150
Server SP4, (SFF) Mezzanine HBA6, 10, 13, 14, 34 ,
Server SP4 SBEFCM4 (SFF) 4Gb Mezzanine HBA6,
10, 14, 67, 81

163 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, 17 See16
Windows 2000: Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server SP4,
Server SP4
164 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y See29
Windows 2000: (26R0890)6, 13, 14, 67 CLARiiON
IBM BladeCenter LS20 (Model 8850) Advanced AX150
Server SP4,
Server SP4
165 Intel SBXD62 Blade Server Microsoft PCI−X Intel: SBEFCM (SFF) Mezzanine HBA6, FC−SW EMC Y
Windows 2000: 10, 13, 14, 34 , SBEFCM4 (SFF) 4Gb CLARiiON
Advanced Mezzanine HBA6, 10, 14, 67, 81 AX150
Server SP4,
Server SP4
166 Digital Henge INNO: HR−4850, HR−6850 Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, See1
Windows 2000: Express Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON Y3, 4, 17
Advanced AX150
Server SP49,
Server SP4
167 Samsung: ZSS230, ZSS230D Microsoft PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y3, 4, 17 See1
Windows 2000: Express AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Advanced AX150
Server SP49,
Server SP4
168 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y3, 4, 17 See1
Windows 2000: Express, Module AHWFCMOD6, 10, 13, 14, 45, 49 CLARiiON
Intel: SR4850HW4−M/SR6850HW4−M, Advanced PCI−X AX150
SR4850HW4/SR6850HW4; Server SP49,
Server SP4
Lenovo SureServer: R630 G5, R650, R650 G5, T650
169 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM Emulex LP1005DC FC Exp Card2, 6, FC−SW EMC Y See29
8832)29, 8832−N1X), 8843); Windows 2000: 7, 8, 10, 71 CLARiiON
Advanced AX150
IBM BladeCenter HS40 (Model 8839) Server SP49,
Server SP4
170 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC Y See29
8832)29, 8843); Windows 2000: (26R0884)6, 13, 14, 67 CLARiiON
Advanced AX150
IBM BladeCenter: HS40 (Model 8839), LS20 (Model Server SP49,
8850) Server SP4
171 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM HS20 FC Exp Card (13N2203)10, 13, FC−SW EMC Y See29
8832)29, 8832−N1X); Windows 2000: 14, 27, 30 CLARiiON
Advanced AX150
IBM BladeCenter HS40 (Model 8839) Server SP49,
Server SP4
172 IBM BladeCenter HS20 (Model: 7981), 8843) Microsoft PCI−X IBM HS20 FC Exp Card (13N2203)10, 13, FC−SW EMC Y See29
Windows 2000: 14, 27, 30, 66 CLARiiON
Advanced AX150
Server SP49,
Server SP4
173 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft PCI−X IBM HS20 FC Exp Card (26K4841)10, 13, FC−SW EMC Y See29
Windows 2000: 14, 27, 30, 58 CLARiiON
IBM BladeCenter LS20 (Model 8850) Advanced AX150
Server SP49,
Server SP4
174 IBM BladeCenter HS20 (Model: 7981), 8678)29, Microsoft PCI−X IBM HS20 FC Exp Card (48P7061)6, 10, FC−SW EMC Y See29
8832)29, 8843); Windows 2000: 13, 14, 27 CLARiiON
Advanced AX150
IBM BladeCenter HS40 (Model 8839) Server SP49,
Server SP4
1. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
2. BIOS 1.70a3
3. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
4. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
5. Firmware Version 2.10a10
6. SNIA HBA API Supported.
7. Driver Version 2.40a3 SCSI FC Port driver
8. Driver Version 2.41a1 SCSI FC Port driver
9. Windows 2000 hosts running less than SP4 could be susceptible to data loss during LUN expansion operations. This issue is corrected by Microsoft in SP4, or by applying hotfix
327020. See EMC Solution IS emc73538 and Microsoft Knowledge Base article 327020 for more information.
10. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
11. Firmware Version 1.91a5
12. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
13. Driver Version 9.1.2.10
14. Driver Version 9.1.2.11
15. BIOS 1.05
16. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
17. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
18. The Emulex LP9XXX HBA family requires a host PCI bus capable of supplying 3.3 VDC bus power. The PCI slot can use either 3.3 VDC or 5.0 VDC signaling interfaces.
19. For external boot configurations running EMC Powerpath on Windows 2000, HP Proliant BL30p & BL35p require a minimum of Powerpath version 4.4.1.
20. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
21. BIOS 1.45
22. Not supported with Emulex LP8000−EMC HBA.
23. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
24. For AX100 configurations, only Dell PowerVault systems with dual CPUs are supported.
25. BIOS 1.23
26. Driver Version 9.1.2.10 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114

11/02/2006 231 CLARiiON AX150


CLARiiON AX150

27. BIOS 1.47


28. Driver Version 9.1.2.11 This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
29. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
30. Due to the HS20's embedded FC−SW design, array lun masking is required to assign LUNS to each individual blade server.
31. Internal port(s) on QLogic or McData 4Gb FC switch module(s) must be set to 4Gb to SAN boot.
32. Driver Version 2.40a3
33. BIOS 1.71a0
34. BIOS 1.43
35. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions.
36. Firmware Version 2.50a8
37. Driver Version 2.41a1 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions.
38. BIOS 1.08
39. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
40. BIOS 1.02
41. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar SCSI.)
42. Firmware Version 2.50a6
43. This HBA is equivalent to the QLogic QLA2310.
44. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
45. BIOS 1.06
46. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
47. Proliant DL360 G4 servers with a BIOS prior to P52 may not be running a fully ACPI−compliant BIOS. Emulex 4gb HBAs require the latest ACPI−compliant BIOS and your server may
require Windows 2000 to be reinstalled. You do not need to reinstall Windows 2000 if you had an ACPI−compliant BIOS and then upgraded to a newer ACPI−compliant BIOS. You only
need to reinstall Windows 2000 if you did not have an ACPI BIOS or an ACPI−compliant BIOS before you upgraded the BIOS. Refer to Microsoft knowledge base article 256841 for
more information. (http://support.microsoft.com/?kbid=256841&sd=RMVP)
48. PowerPath supported. ATF/CDE not supported.
49. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
50. Firmware Version 1.91a1
51. Accepts PCI−X 1.0 and 2.0 HBAs.
52. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
53. Driver Version 9.1.2.14
54. BIOS 1.16
55. Update Rollup 1 for Windows 2000 SP4 is supported. For more information on this Rollup and to download the necessary software, please see
http://support.microsoft.com/default.aspx?scid=kb;en−us;891861
56. Host must be offline for interfamily Symmetrix microcode upgrade.
57. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons.
58. Refer to EMC Knowledgebase ID emc105679 for any special HBA drivers that may be required.
59. This HBA is equivalent to the QLogic QLA2340.
60. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
61. For IBM xSeries Servers running Windows 2000 with IBM ServerRaid controller 4M, the ServerRaid Driver must be 6.00 or above for use with EMC PowerPath 3.0 and above. IBM
driver can be downloaded at:
http://www−3.ibm.com/pc/support/site.wss/document.do?lndocid=MIGR−39723
62. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
63. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
64. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
65. Firmware Version 1.91a2
66. Dual−port FC switch module. Can be used in place of Optical PassThru Module (OPM.)
67. BIOS 1.12
68. Driver Version 2.30a2 SCSI FC Port driver
69. Driver Version 2.21a0
70. Driver Version 2.22a8
71. Firmware Version 1.90a5
72. Firmware Version 1.90a4
73. BIOS 1.48
74. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
75. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
76. BX600 uses an embedded fibre channel controller. Contact Fujitsu Siemens to acquire proper BIOS for embedded fibre channel controller.
77. If using Dell PERC Controller, requires PERC 2 or PERC 3 with OpenManager 3.0 and Array Manager 3.1. The afamgt.sys must be version 2.6.0.3486 (or above).
78. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
79. HPQ Proliant ML350 (1GHz) : D04,F04 (11/13/2000) , HPQ Proliant ML350(600,733,800,866,933 MHz) : D02, F04 (11/13/2000).
80. Requires minimum BIOS v4.01 rev A (5/17/2002) for use with Emulex HBAs.
81. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Requires Microsoft STORPort hotfix Q903081. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];903081 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
82. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
83. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
84. Supports Stratus OS 1.3.X through 2.1.X.
85. QLogic SANSurfer/SANBlade Manager is not supported. Use QLogic SANCLI utility.
86. QLogic SanBlade Manager is not supported.
87. Supports Stratus OS 2.0.X through 2.1.X.

Microsoft Windows 2003 [x64]

11/02/2006 232 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
1 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y1
BL465c (403433−B21), BL465c [x64] Enterprise: Edition, Express for HP c−Class Bladesystem FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), Edition R211 (403621−B21)4, 29, 32 AX150
BL465c (407235−B21), BL480c
(404704−B21)
2 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
BL465c (403433−B21), BL465c [x64] Enterprise: Edition, Express HP c−Class Bladesystem (403619−B21)28, FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), Edition R211 52 AX150
BL465c (407235−B21), BL480c
(404704−B21)
3 Fujitsu Siemens Primergy BX620: S2F57, Microsoft Windows 2003 PCI Emulex LP1050−E4, 8, 9, 33 FC−AL, EMC Y1, 15 See14
S257; [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Fujitsu Siemens Primergy BX630: (2−way),
(4−way) Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
4 Fujitsu Siemens Primergy BX620: S2F57, Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q6, 19, 56, 58 FC−AL, EMC Y1
S257, S3; [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Fujitsu Siemens Primergy BX630: (2−way),
(4−way), (8−way) Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
5 Fujitsu Siemens Primergy: RX200 S2, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E4, 6, 8, 9, 33 FC−AL, EMC Y1, 2, 15, See14
S2, TX600 S2 [x64] Enterprise: Edition, Express FC−SW CLARiiON Y1, 15
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
6 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex LP1150−E4, 6, 7, 8, 9, 16 FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
7 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI Emulex LPe111−E4, 6, 7, 9, 29 FC−AL, EMC Y1, 2, 15 See14
6850; [x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
Fujitsu Siemens Primergy RX300 S3; [x64] Standard: Edition,
HPQ Proliant: DL360(G4)3, DL380(G4)3, Edition R211
DL580(G3)3;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
8 Dell PowerEdge: 1850, 1950, 2800; Microsoft Windows 2003 PCI Emulex LPe111−E4, 6, 7, 9, 29 FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; Edition R211; AX150
Digital Henge Revo: JS1400, JS2400; Microsoft Windows 2003
[x64] Standard: Edition,
Fujitsu Siemens Primergy RX300 S3; Edition R211
HPQ Proliant: DL360(G4)3, DL380(G4)3,
DL580(G3)3;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
9 Fujitsu Siemens Primergy RX300 S3 Microsoft Windows 2003 PCI Emulex LPe1150−E4, 6, 8, 9, 59 FC−AL, EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express FC−SW CLARiiON Y1, 15
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
10 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex: LP1050−E4, 7, 8, 9, 34 , LP1150−E4, FC−AL, EMC Y1, 15, 20 See14
[x64] Enterprise: Edition, Express 6, 7, 8, 9, 16 , LP982−E4, 7, 8, 9, 34 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
11 Dell PowerEdge 1950; Microsoft Windows 2003 PCI Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15 See14
Samsung: ZSS230, ZSS230D [x64] Enterprise: Edition, Express 7, 8, 9, 34 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
12 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 8, 9, 34 , FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express LPe1150−E4, 5, 6, 7, 8, 9 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Edition R211; AX150
HPQ Proliant: DL360(G4)3, DL380(G4)3, Microsoft Windows 2003
DL580(G3)3; [x64] Standard: Edition,
Edition R211
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D

11/02/2006 233 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
13 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 8, 9, 34 , FC−AL, EMC Y1, 2, 15 See14
[x64] Enterprise: Edition, Express LPe1150−E4, 5, 6, 7, 8, 9 FC−SW CLARiiON
HPQ Proliant: DL360(G4)3, DL380(G4)3, Edition R211; AX150
DL580(G3)3;
Microsoft Windows 2003
IBM xSeries x3455 (7984); [x64] Standard: Edition,
LangChao: NC3000, NC3500, NF500, Edition R211
NF520;
Samsung: ZSS230, ZSS230D
14 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 9, 34 , FC−AL, EMC Y1, 2, 15 See14
6850 [x64] Enterprise: Edition, Express LPe1150−E4, 5, 6, 7, 9 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
15 Dell PowerEdge: 1850, 1950, 2800 Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 9, 34 , FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express LPe1150−E4, 5, 6, 7, 9 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
16 HPQ Proliant DL360(G4)3 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)4, 6, 7, 8, 9 FC−AL, EMC Y1, Y1, 2
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
17 HPQ Proliant: DL360(G4)3, DL380(G4)3, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)4, 5, 6, FC−AL, EMC Y1, Y1, 2
DL580(G3)3 [x64] Enterprise: Edition, Express 7, 8 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
18 HPQ Proliant: DL360(G4)3, DL380(G4)3 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)6, 9, 12, FC−AL, EMC Y1, Y1, 2
[x64] Enterprise: Edition, Express 18, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
19 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)4, 5, 32, 53, 54 FC−AL, EMC Y1, 15 See14
120Ri−2 [x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
20 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)4, 5, 32, 53, 54 FC−AL, EMC Y1, 15, 55 See14, 26
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
21 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA2340−E−SP9, 12, 19 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
22 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP6, 9, 27, 28 FC−AL, EMC Y1, 2, 15 See26
6850; [x64] Enterprise: Edition, Express FC−SW CLARiiON
Edition R211; AX150
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
IBM xSeries x3455 (7984); [x64] Standard: Edition,
LangChao: NC3000, NC3500, NF500, Edition R211
NF520;
Samsung: ZSS230, ZSS230D
23 Dell PowerEdge: 1850, 1950, 2800; Microsoft Windows 2003 PCI QLogic QLE220−E−SP6, 9, 27, 28 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; Edition R211; AX150
Digital Henge Revo: JS1400, JS2400; Microsoft Windows 2003
[x64] Standard: Edition,
IBM xSeries x3455 (7984); Edition R211
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
24 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP9, 12, 18, 19 , FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express QLA2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211

11/02/2006 234 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
25 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP6, 9, 27, 28 , FC−AL, EMC Y1, 15, 20 See26
[x64] Enterprise: Edition, Express QLE2360−E−SP9, 12, 18, 35 , FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Edition R211; QLE2460−E−SP6, 9, 12, 18, 36 AX150
NF520;
Microsoft Windows 2003
Samsung: ZSS230, ZSS230D [x64] Standard: Edition,
Edition R211
26 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 12, 18, 35 , FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express QLE2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Edition R211; AX150
IBM xSeries x3455 (7984); Microsoft Windows 2003
LangChao: NC3000, NC3500, NF500, [x64] Standard: Edition,
NF520; Edition R211
Samsung: ZSS150, ZSS230, ZSS230D
27 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 12, 18, 35 , FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express QLE2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
IBM xSeries x3455 (7984); Edition R211; AX150
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung: ZSS230, ZSS230D Edition R211
28 Dell PowerEdge: 1800, 1950, 2850, 6800, Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 12, 35, FC−AL, EMC Y1, 2, 15 See26
6850 [x64] Enterprise: Edition, Express QLE2460−E−SP6, 9, 12, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
29 Dell PowerEdge: 1850, 1950, 2800 Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 12, 35, FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express QLE2460−E−SP6, 9, 12, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
30 Fujitsu Siemens Primergy: RX220, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E4, 6, 8, 9, 33 FC−AL, EMC Y1, 2, 15, See14
S3, TX600 S3 [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y1, 15
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
31 IBM: eServer 326m (Model 7969), xSeries Microsoft Windows 2003 PCI Emulex LP1050Ex−E4, 6, 8, 9, 34 FC−AL, EMC Y1, 2, 15, See14
x3550 (7978), xSeries x3650 (7979), xSeries [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y1, 15
x3755 (8877) 11
Edition R2 ; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
32 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LP1150−E4, 6, 7, 8, 9, 16 FC−AL, EMC Y1, 15, See14
[x64] Enterprise: Edition, Express, FC−SW CLARiiON Y1, 15, 20
Intel: SC5300AF2, SE7520BB2, 11
Edition R2 ; PCI−X AX150
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M, Microsoft Windows 2003
SR4850HW4/SR6850HW4; [x64] Standard: Edition,
Edition R211
Lenovo SureServer: R630 G5, R650, R650
G5, T650
33 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E4, 6, 7, 9, 29 FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
11
Digital Henge INNO: HR−4850T, HR−6850T; Edition R2 ; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R211
Fujitsu Siemens Primergy: RX200 S3,
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132

11/02/2006 235 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
34 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E4, 6, 7, 9, 29 FC−AL, EMC Y1, 2, 15 See14
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Edition R211; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R211
Fujitsu Siemens Primergy: RX200 S3,
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
35 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex LPe1150−E4, 5, 6, 8, 9 FC−AL, EMC Y1, 2, 15 See14
x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
36 Fujitsu Siemens Primergy: RX200 S3, Microsoft Windows 2003 PCI Emulex LPe1150−E4, 6, 8, 9, 59 FC−AL, EMC Y1, 2, 15, See14
RX220, RX600 S3, TX300 S3, TX600 S3 [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y1, 15
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
37 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express, 7, 8, 9, 34 FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Edition R211; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R211
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
38 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15, 20 See14
[x64] Enterprise: Edition, Express, 7, 8, 9, 34 FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Edition R211; PCI−X AX150
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x64] Standard: Edition,
SR1400/SE7520JR2, SR2400/SE7520JR2, Edition R211
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
39 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP1050−E4, 8, 9, 34, LP1150−E4, 6, FC−AL, EMC Y1, 15 See14
x3755 (8877) [x64] Enterprise: Edition, Express, 8, 9, 16, LP982−E4, 8, 9, 34, LPe1150−E4, 5, FC−SW CLARiiON
11
Edition R2 ; PCI−X 6, 8, 9 AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
40 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 8, 9, 34 , FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express, LPe1150−E4, 5, 6, 7, 8, 9 FC−SW CLARiiON
IBM eServer 326m (Model 7969); 11
Edition R2 ; PCI−X AX150
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x64] Standard: Edition,
SR4850HW4/SR6850HW4; Edition R211
Lenovo SureServer: R630 G5, R650, R650
G5, T650
41 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 8, 9, 34 , FC−AL, EMC Y1, 2, 15 See14
[x64] Enterprise: Edition, Express, LPe1150−E4, 5, 6, 7, 8, 9 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Edition R211; PCI−X AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x64] Standard: Edition,
Lenovo SureServer: R630 G5, R650, R650 Edition R211
G5, T650
42 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E4, 6, 7, 9, 34 , FC−AL, EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express, LPe1150−E4, 5, 6, 7, 9 FC−SW CLARiiON Y1, 15
Digital Henge Revo: AS1500, AS1550, 11
Edition R2 ; PCI−X AX150
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x64] Standard: Edition,
SR2500/S5000PAL; Edition R211
Samsung ZSS132

11/02/2006 236 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
43 HPQ Proliant ML350(G4)3 Microsoft Windows 2003 PCI HPQ: AB429A/FC1143 (QLA2460)6, 9, 12, FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, 36, AE369A/FC1243 (QLA2462)6, 9, 12, 36 FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
44 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)9, 12, 17, 18, 19 FC−AL, EMC Y1, 20
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
45 IBM xSeries: x346 (8840)75, x3550 (7978), Microsoft Windows 2003 PCI IBM 24P0960 (QLA2340)9, 12, 18, 19, 37 FC−AL, EMC Y1
x3650 (7979) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
46 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)6, 9, 12, 18, 19 FC−AL, EMC N, Y1, 2, See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON 15, Y1,
Edition R211; PCI−X AX150 15, Y1,
15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
47 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)6, 9, 12, 18, 19 FC−AL, EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express, FC−SW CLARiiON Y1, 15,
Edition R211; PCI−X AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
48 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM: 19K1246 (QLA2310)9, 12, 17, 18, 19 , FC−AL, EMC Y1
[x64] Enterprise: Edition, Express, 24P8053 (QLA2342)6, 9, 12, 18, 19 FC−SW CLARiiON
11
Edition R2 ; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
49 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)6, 9, 36, 60 , FC−AL, EMC Y1, 15 See26
x3755 (8877) [x64] Enterprise: Edition, Express, 39M5895 (QLA2462)6, 9, 36, 60 ; FC−SW CLARiiON
11
Edition R2 ; PCI−X AX150
QLogic: QLA2340−E−SP9, 18, 19,
Microsoft Windows 2003 QLA2460−E−SP6, 9, 18, 36 ,
[x64] Standard: Edition, QLE2460−E−SP6, 9, 18, 36
Edition R211
50 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2340−E−SP9, 12, 18, 19 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), 11
Edition R2 ; PCI−X AX150
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x64] Standard: Edition,
SR1400/SE7520JR2, SR2400/SE7520JR2, Edition R211
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
51 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic QLA2340−E−SP9, 12, 18, 19 FC−AL, EMC Y1, 15, 20 See26
x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
11
Edition R2 ; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
52 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2460−E−SP6, 9, 12, 18, 36 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, Edition R211; PCI−X AX150
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M, Microsoft Windows 2003
SR4850HW4/SR6850HW4; [x64] Standard: Edition,
Edition R211
Lenovo SureServer: R630 G5, R650, R650
G5, T650
53 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP6, 9, 27, 28 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
11
Digital Henge INNO: HR−4850T, HR−6850T; Edition R2 ; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R211
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR1500/S5000PAL,
SR2400/SE7520JR2, SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132

11/02/2006 237 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
54 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP6, 9, 27, 28 FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Edition R211; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x64] Standard: Edition,
Edition R211
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
55 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE2360−E−SP9, 12, 35 FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Edition R211; PCI−X AX150
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x64] Standard: Edition,
SR2500/S5000PAL; Edition R211
Samsung ZSS132
56 IBM xSeries: x346 (8840)75, x3550 (7978), Microsoft Windows 2003 PCI QLogic QLE2360−E−SP9, 18, 35 FC−AL, EMC Y1, 2, 15, See26
x3650 (7979), x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON Y1, 15
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
57 Dell PowerEdge: 1900, 2900, 2950, 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP6, 9, 12, 36 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
58 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic QLE2460−E−SP6, 9, 18, 36 FC−AL, EMC Y1, 2, 15 See26
x3755 (8877) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
59 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP9, 12, 19, FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, QLE2360−E−SP9, 12, 35 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Edition R211; PCI−X AX150
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x64] Standard: Edition,
SR2500/S5000PAL; Edition R211
Samsung ZSS132
60 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP6, 9, 27, 28 , FC−AL, EMC Y1, 15, 20 See26
[x64] Enterprise: Edition, Express, QLE2360−E−SP9, 12, 18, 35 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); Edition R211; PCI−X QLE2460−E−SP6, 9, 12, 18, 36 AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x64] Standard: Edition,
Lenovo SureServer: R630 G5, R650, R650 Edition R211
G5, T650
61 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 12, 18, 35 , FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, QLE2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
IBM eServer 326m (Model 7969); 11
Edition R2 ; PCI−X AX150
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x64] Standard: Edition,
SR4850HW4/SR6850HW4; Edition R211
Lenovo SureServer: R630 G5, R650, R650
G5, T650
62 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 12, 18, 35 , FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express, QLE2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Edition R211; PCI−X AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x64] Standard: Edition,
Lenovo SureServer: R630 G5, R650, R650 Edition R211
G5, T650
63 Dell PowerEdge 6850 Microsoft Windows 2003 PCI−X Dell 2362M9, 10, 12, 13 FC−AL, EMC Y1
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
64 Dell PowerEdge 1855 Microsoft Windows 2003 PCI−X Dell: 2342M9, 12, 19, LPe1105−M4, 5, 6, 7, FC−AL, EMC Y1
[x64] Enterprise: Edition, QME24626, 12, 22 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211

11/02/2006 238 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
65 Fujitsu Siemens Primergy: RX200 S2, RX300 Microsoft Windows 2003 PCI−X Emulex LP1050−E4, 8, 9, 33 FC−AL, EMC Y1, 15 See14
S2, TX200 S2, TX300 S2 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
66 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X Emulex LP1150−E4, 6, 7, 8, 9, 16 FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, FC−SW CLARiiON
HPQ Proliant DL360(G4)3; Edition R211; AX150
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung ZSS150; Edition R211
Sun: V20z, V40z, x4100, x4200
67 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X Emulex LP1150−E4, 6, 7, 8, 9, 16 FC−AL, EMC Y1, 15, 20 See14
[x64] Enterprise: Edition, FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Edition R211; AX150
NF520;
Microsoft Windows 2003
Samsung ZSS150; [x64] Standard: Edition,
Sun: x4100, x4200 Edition R211
68 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E4, 6, 8, 9, 16 FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
69 Dell PowerEdge: 1800, 2800, 2850, 6800, Microsoft Windows 2003 PCI−X Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15 See14
6850; [x64] Enterprise: Edition, 7, 8, 9, 34 FC−SW CLARiiON
Edition R211; AX150
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
HPQ Proliant DL360(G4)3; [x64] Standard: Edition,
LangChao: NC3000, NC3500, NF500, Edition R211
NF520;
Samsung ZSS150;
Sun: V20z, V40z, x4100, x4200
70 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15, 20 See14
[x64] Enterprise: Edition, 7, 8, 9, 34 FC−SW CLARiiON
IBM xSeries x3850/x366 (8863)24, 25; Edition R211; AX150
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung ZSS150 Edition R211
71 Fujitsu Siemens Primergy: RX600 S2, TX600 Microsoft Windows 2003 PCI−X Emulex: LPe111−E4, 6, 7, 9, 29 , FC−AL, EMC Y1, 2, 15, See14
S2 [x64] Enterprise: Edition, LPe1150−E4, 6, 8, 9, 59 FC−SW CLARiiON Y1, 15
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
72 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y1
(416654−B21), (416655−B21), [x64] Enterprise: Edition, for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); Edition R211; (403621−B21)4, 29, 32 AX150
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x64] Standard: Edition,
Edition R211
73 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), [x64] Enterprise: Edition, HP c−Class Bladesystem (403619−B21)28, FC−SW CLARiiON
(416656−B21), (432636−B21); Edition R211; 52 AX150
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x64] Standard: Edition,
Edition R211
74 HPQ Proliant DL360(G4)3 Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)4, 7, 8, 9, 34 , A7388A FC−AL, EMC Y1
[x64] Enterprise: Edition, (LP1050)4, 7, 8, 9, 34 , AD167A/FC2143 FC−SW CLARiiON
Edition R211; (LP1150)4, 6, 7, 8, 61 , FCA2214 (QLA2340)9, AX150
12, 18, 19 , FCA2408 (LP982)4, 6, 7, 8, 9, 34
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
75 HPQ Proliant DL360(G4)3 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)6, 9, 12, FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, 36, AE369A/FC1243 (QLA2462)6, 9, 12, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
76 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ: Dual−port Fibre Channel Adapter for FC−AL, EMC Y1
[x64] Enterprise: Edition, HP Proliant BL25p/BL45p 381881−B219, 12, FC−SW CLARiiON
Edition R211; 18, 73, Emulex−based BL25/30/35/45p Fibre AX150
Channel Mezzanine HBA − 394588−B214,
Microsoft Windows 2003 9, 40, 50
[x64] Standard: Edition,
Edition R211
77 IBM xSeries x3850/x366 (8863)24, 25 Microsoft Windows 2003 PCI−X IBM 19K1246 (QLA2310)9, 12, 17, 18, 19 FC−AL, EMC Y1, 20
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211

11/02/2006 239 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
78 NEC Express 5800: 110Rg−1, 180Re−3 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)4, 7, 8, 9, 34, 53 FC−AL, EMC Y1
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
79 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)4, 7, 8, 9, 34, 53 FC−AL, EMC Y1, 15 See14
120Ri−2 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
80 NEC Express 5800: 120Rf−1, 120Rh−2 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)4, 7, 8, 9, 34, 53 FC−AL, EMC Y1, 15
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
81 IBM xSeries x3850/x366 (8863)24, 25 Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP9, 12, 18, 19 FC−AL, EMC Y1, 15, 20 See26
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
82 Dell PowerEdge: 1800, 2800, 2850, 6800, Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP9, 12, 19 FC−AL, EMC Y1, 15 See26
6850 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
83 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP6, 9, 18, 36 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
84 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic: QLA2340−E−SP9, 12, 18, 19 , FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, QLA2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
HPQ Proliant DL360(G4)3; Edition R211; AX150
LangChao: NC3000, NC3500, NF500,
NF520; Microsoft Windows 2003
[x64] Standard: Edition,
Samsung ZSS150; Edition R211
Sun: V20z, V40z, x4100, x4200
85 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X21 Emulex: LP1050−E4, 7, 8, 9, 34 , LP1150−E4, FC−AL, EMC Y1, 15, See14
[x64] Enterprise: Edition, 6, 7, 8, 9, 16 , LP982−E4, 7, 8, 9, 34 FC−SW CLARiiON Y1, 15, 20
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
86 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X21 QLogic: QLA2340−E−SP9, 12, 18, 19 , FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, QLA2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
87 IBM xSeries x3800/x260 (8865)24 Microsoft Windows 2003 PCI−X23 Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15, 20 See14
[x64] Enterprise: Edition, 7, 8, 9, 34 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
88 IBM xSeries: x3800/x260 (8865)24, Microsoft Windows 2003 PCI−X23 Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15 See14
x3950/x3950E/x460 (8872, 8874)24 [x64] Enterprise: Edition, 7, 8, 9, 34 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
89 IBM xSeries x3800/x260 (8865)24 Microsoft Windows 2003 PCI−X23 IBM 19K1246 (QLA2310)9, 12, 17, 18, 19 FC−AL, EMC Y1, 20
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
90 IBM xSeries: x3800/x260 (8865)24, Microsoft Windows 2003 PCI−X23 IBM: 19K1246 (QLA2310)9, 12, 17, 18, 19 , FC−AL, EMC Y1
x3950/x3950E/x460 (8872, 8874)24 [x64] Enterprise: Edition, 24P0960 (QLA2340)9, 12, 18, 19, 37 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
91 IBM xSeries x3800/x260 (8865)24 Microsoft Windows 2003 PCI−X23 QLogic QLA2340−E−SP9, 12, 18, 19 FC−AL, EMC Y1, 15, 20 See26
[x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211

11/02/2006 240 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
92 IBM xSeries: x3800/x260 (8865)24, Microsoft Windows 2003 PCI−X23 QLogic QLA2340−E−SP9, 12, 18, 19 FC−AL, EMC Y1, 15 See26
x3950/x3950E/x460 (8872, 8874)24 [x64] Enterprise: Edition, FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
93 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X39 HPQ Dual−port Fibre Channel Adapter for FC−AL, EMC Y1
[x64] Enterprise: Edition, HP Proliant BL25p/BL45p 381881−B219, 12, FC−SW CLARiiON
Edition R211; 18, 73 AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
94 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X39 HPQ Emulex−based BL25/30/35/45p Fibre FC−AL, EMC N
[x64] Enterprise: Edition, Channel Mezzanine HBA − 394588−B214, FC−SW CLARiiON
Edition R211; 9, 40, 50 AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
95 HPQ Proliant BL20p: (G3), (G4) Microsoft Windows 2003 PCI−X39 HPQ: Dual−port Fibre Channel Adapter for FC−AL, EMC N
[x64] Enterprise: Edition, HP Proliant BL20p (G3) 361426−B219, 12, FC−SW CLARiiON
Edition R211; 18, 38, Emulex−based BL20p (G3) Fibre AX150
Channel Mezzanine HBA − 394757−B214,
Microsoft Windows 2003 7, 8, 9, 40
[x64] Standard: Edition,
Edition R211
96 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M9, 12, 19, LPe1105−M4, 5, 6, 7, FC−AL, EMC Y1
[x64] Enterprise: Edition, Express, QME24626, 12, 22 FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
97 HPQ Proliant DL380(G4)3 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E4, 6, 7, 8, 9, 34 FC−AL, EMC Y1, 2, 15 See14
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
98 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E4, 6, 7, 9, 29 FC−AL, EMC Y1, 2, 15 See14
HPQ Proliant DL380(G4)3 [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
99 HPQ Proliant: DL380(G4)3, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E4, 5, 6, 7, 8, 9 FC−AL, EMC Y1, 2, 15 See14
DL580(G4) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
100 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E4, 6, 8, 9, 59 FC−AL, EMC Y1, 2, 15 See14
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
101 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex: LP1150−E4, 6, 7, 8, 9, 16 , FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express, LPe1150−E4, 5, 6, 7, 8, 9 FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
102 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E4, 6, 7, 9, 29 , FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, Express, LPe1150−E4, 6, 8, 9, 59 FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
103 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)4, 5, 6, FC−AL, EMC Y1
[x64] Enterprise: Edition, Express, 7, 8, AD167A/FC2143 (LP1150)4, 6, 7, 8, 61 , FC−SW CLARiiON
Edition R211; PCI−X AE311A/FC1142SR (QLE2460)6, 9, 12, 18, AX150
36
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
104 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)4, 5, 6, FC−AL, EMC Y1, 2
[x64] Enterprise: Edition, Express, 7, 8, AE311A/FC1142SR (QLE2460)6, 9, 12, FC−SW CLARiiON
Edition R211; PCI−X 18, 36 AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
105 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)6, 9, 12, FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, Express, 36, AE369A/FC1243 (QLA2462)6, 9, 12, 36 ; FC−SW CLARiiON
Edition R211; PCI−X AX150
QLogic QLA2460−E−SP6, 9, 12, 18, 36
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211

11/02/2006 241 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
106 HPQ Proliant DL580(G3)3 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP6, 9, 27, 28 FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
107 HPQ Proliant: DL380(G4)3, DL580(G3)3 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP9, 12, 18, 35 FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
108 HPQ Proliant: DL380(G4)3, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP6, 9, 12, 18, 36 FC−AL, EMC Y1, 2, 15 See26
DL580(G3)3, DL580(G4) [x64] Enterprise: Edition, Express, FC−SW CLARiiON
Edition R211; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
109 Fujitsu Siemens Primergy RX800 S2 Microsoft Windows 2003 PCI, Emulex LP1050−E4, 8, 9, 33 FC−AL, EMC Y1, 15 See14
[x64] Enterprise: Edition, PCI−X FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
110 HPQ Proliant: DL380(G4)3, DL3853, Microsoft Windows 2003 PCI, Emulex LP1150−E4, 6, 7, 8, 9, 16 FC−AL, EMC Y1, 15 See14
DL580(G3)3, DL5853 [x64] Enterprise: Edition, PCI−X FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
111 Dell PowerEdge 1850; Microsoft Windows 2003 PCI, Emulex: LP1050−E4, 7, 8, 9, 34 , LP982−E4, FC−AL, EMC Y1, 15 See14
HPQ Proliant: DL380(G4)3, DL3853, [x64] Enterprise: Edition, PCI−X 7, 8, 9, 34 FC−SW CLARiiON
DL580(G3)3, DL5853 Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
112 HPQ Proliant: DL380(G4)3, DL3853, DL5853 Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)4, 7, 8, 9, 34 , A7388A FC−AL, EMC Y1
[x64] Enterprise: Edition, PCI−X (LP1050)4, 7, 8, 9, 34 , AD167A/FC2143 FC−SW CLARiiON
Edition R211; (LP1150)4, 6, 7, 8, 61 , FCA2214 (QLA2340)9, AX150
12, 18, 19 , FCA2408 (LP982)4, 6, 7, 8, 9, 34
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
113 HPQ Proliant: DL380(G4)3, DL3853, DL5853 Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)6, 9, 12, FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, PCI−X 36, AE369A/FC1243 (QLA2462)6, 9, 12, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
114 Dell PowerEdge 1850 Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP9, 12, 19 FC−AL, EMC Y1, 15 See26
[x64] Enterprise: Edition, PCI−X FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
115 HPQ Proliant: DL380(G4)3, DL3853, Microsoft Windows 2003 PCI, QLogic: QLA2340−E−SP9, 12, 18, 19 , FC−AL, EMC Y1, 15 See26
DL580(G3)3, DL5853 [x64] Enterprise: Edition, PCI−X QLA2460−E−SP6, 9, 12, 18, 36 FC−SW CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
116 Dell PowerEdge 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP6, 9, 12, 36 FC−AL, EMC Y1, 2, 15 See26
[x64] Enterprise: Edition, Express, FC−SW CLARiiON
11
Edition R2 ; PCI−X AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211;
Microsoft Windows 2003
[x64] Storage Server:
Enterprise Edition R2,
Standard Edition R2
117 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX: (LP1050)4, 7, 34, FC−AL, EMC Y
[x64] Standard Edition 41, 69, 70 , (LP1050)4, 7, 34, 41, 70 FC−SW CLARiiON
R211 AX150
118 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)4, 34, 47, FC−AL, EMC Y1
[x64] Standard Edition PCI−X 72 FC−SW CLARiiON
R211 AX150
119 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y1
(403434−B21), (407234−B21), [x64] Standard: Edition, Express for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21); Edition R211 (403621−B21)4, 29, 32 AX150
HPQ Proliant BL480c (404704−B21)

11/02/2006 242 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
120 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403434−B21), (407234−B21), [x64] Standard: Edition, Express HP c−Class Bladesystem (403619−B21)28, FC−SW CLARiiON
(407235−B21); Edition R211 52 AX150
HPQ Proliant BL480c (404704−B21)
121 Dell PowerEdge: 2900, 2950 Microsoft Windows 2003 PCI Emulex: LP1050−E4, 7, 8, 9, 34 , FC−AL, EMC Y1, 15 See14
[x64] Storage Server: Express, LP1050Ex−E4, 6, 7, 9, 34 , LP982−E4, 7, 8, 9, FC−SW CLARiiON
Enterprise Edition R2, PCI−X 34, LPe111−E4, 6, 7, 9, 29 , LPe1150−E4, 5, 6, AX150
Standard Edition R2 7, 9

122 Dell PowerEdge: 2900, 2950, 6950 Microsoft Windows 2003 PCI QLogic QLE2460−E−SP6, 9, 12, 36 FC−AL, EMC Y1, 15 See26
[x64] Storage Server: Express, FC−SW CLARiiON
Enterprise Edition R2, PCI−X AX150
Standard Edition R2
123 Dell PowerEdge: 2900, 2950 Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP9, 12, 19, FC−AL, EMC Y1, 15 See26
[x64] Storage Server: Express, QLE220−E−SP6, 9, 27, 28 , FC−SW CLARiiON
Enterprise Edition R2, PCI−X QLE2360−E−SP9, 12, 35 AX150
Standard Edition R2
124 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X23 Emulex: LP101−E4, 9, 34, 48, 51 , FC−AL, EMC Y1, 15 See14
8874)24 [x64]: DataCenter, LP1050−E4, 7, 8, 9, 34 , LP1050−E4, 9, 34, 48, FC−SW CLARiiON
DataCenter R211 49, 50, LP982−E4, 7, 8, 9, 34 , LP982−E4, 9, 34, AX150
48, 49, 50

125 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X23 IBM 19K1246: (QLA2310)9, 12, 17, 18, 19 , FC−AL, EMC Y1
8874)24 [x64]: DataCenter, (QLA2310)9, 17, 19, 43, 44, 45 ; FC−SW CLARiiON
DataCenter R211 AX150
IBM 24P0960: (QLA2340)9, 12, 18, 19, 37 ,
(QLA2340)9, 19, 37, 43, 44, 45
126 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X23 QLogic: QLA2340−E−SP9, 12, 18, 19 , FC−AL, EMC Y1, 15 See26
8874)24 [x64]: DataCenter, QLA2340−E−SP9, 19, 43, 45 FC−SW CLARiiON
DataCenter R211 AX150
127 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)4, 34, 41, FC−AL, EMC Y
[x64]: DataCenter, 42 FC−SW CLARiiON
Enterprise Edition, AX150
Standard Edition
128 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)4, 34, 46, FC−AL, EMC N
[x64]: DataCenter, PCI−X 47 FC−SW CLARiiON
Enterprise Edition, AX150
Standard Edition,
Standard Edition R211
129 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
130 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See26
[x64] Enterprise: Edition, Express Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Edition R211; AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
131 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Edition R211; AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
132 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y1, 2, 15, See26
[x64] Enterprise: Edition, Express AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Edition R211; AX150 Y1, 15, 20
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
133 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See14
[x64] Enterprise: Edition, Express, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Intel: SR4850HW4−M/SR6850HW4−M, Edition R211; PCI−X AX150 Y1, 15, 20
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x64] Standard: Edition,
G5, T650 Edition R211
134 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 2, 15, See26
[x64] Enterprise: Edition, Express, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15,
Intel: SR4850HW4−M/SR6850HW4−M, Edition R211; PCI−X AX150 Y1, 15, 20
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x64] Standard: Edition,
G5, T650 Edition R211
135 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y1
[x64] Enterprise: Edition, port: for NovaScale Blade Series CLARiiON
Edition R211; CFSN202−11009, 12, 18, 31 , mini for AX150
NovaScale Blade 2021 CFSN202−21009,
Microsoft Windows 2003 12, 18, 31 ;
[x64] Standard: Edition,
Edition R211 Bull: SBEFCM (SFF) Mezzanine HBA6, 9,
12, 18, 31 , SBEFCM4 (SFF) 4Gb Mezzanine
HBA6, 9, 12, 68, 74
136 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 15 See26
[x64] Enterprise: Edition, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211

11/02/2006 243 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
137 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y1, 15, See14
[x64] Enterprise: Edition, Module AHWFCMOD6, 9, 10, 12, 13, 18 CLARiiON Y1, 15, 20
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
138 IBM BladeCenter: HS20 (Model 8843), HS21 Microsoft Windows 2003 PCI−X IBM Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y1, 63 See30
(Model 8853)64, 71, HS21 (Model 8853)71, [x64] Enterprise: Edition, Card (39Y9186)6, 16, 32, 62 CLARiiON
LS20 (Model 8850), LS21 (Model 7971)64, Edition R211; AX150
LS41 (Model 7972)64
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
139 IBM BladeCenter HS20 (Model: 8832−N1X), Microsoft Windows 2003 PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC Y1 See30
8843); [x64] Enterprise: Edition, (26R0884)6, 12, 18, 68 CLARiiON
Edition R211; AX150
IBM BladeCenter LS20 (Model 8850)
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
140 IBM BladeCenter HS20 (Model 8843) Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)9, 12, 18, FC−SW EMC Y1 See30
[x64] Enterprise: Edition, 19, 65, 66, 67 CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
141 IBM BladeCenter HS20 (Model 8832−N1X) Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)9, 12, 18, FC−SW EMC Y1 See30
[x64] Enterprise: Edition, 19, 66, 67 CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
142 IBM BladeCenter: HS20 (Model 8843), HS40 Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (48P7061)6, 9, 12, FC−SW EMC Y1 See30
(Model 8839) [x64] Enterprise: Edition, 18, 19 CLARiiON
Edition R211; AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
143 IBM BladeCenter: HS20 (Model 8843), HS21 Microsoft Windows 2003 PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y1 See30
(Model 8853)64, 71, LS20 (Model 8850), LS21 [x64] Enterprise: Edition, (26R0890)6, 12, 18, 68 , FC Exp Card CLARiiON
(Model 7971)64, LS41 (Model 7972)64 Edition R211; (26K4841)9, 12, 18, 19, 65, 66, 67 AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
144 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA6, 9, FC−SW EMC Y1
[x64] Enterprise: Edition, 12, 18, 31 , SBEFCM4 (SFF) 4Gb Mezzanine CLARiiON
Edition R211; HBA6, 9, 12, 68, 74 AX150
Microsoft Windows 2003
[x64] Standard: Edition,
Edition R211
1. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
2. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
3. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
4. BIOS 1.70a3
5. Firmware Version 2.50a6
6. SNIA HBA API Supported.
7. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
8. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
9. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
10. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
11. VDS (Virtual Disk Service) is currently supported for Windows 2003 R2 operating systems. EMC Solutions Enabler 6.2 (minimum version) is required to support VDS for Windows 2003
R2.
12. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
13. BIOS 1.06
14. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
15. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
16. Firmware Version 2.10a10
17. This HBA is equivalent to the QLogic QLA2310.
18. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
19. BIOS 1.47
20. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar SCSI.)
21. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
22. BIOS 1.11
23. Accepts PCI−X 1.0 and 2.0 HBAs.
24. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
25. x64 versions of Windows 2003 require the Adaptec SAS SCSI driver from the IBM Support website.
26. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
27. BIOS 1.02
28. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
29. Firmware Version 2.50a8
30. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
31. BIOS 1.43
32. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
33. Firmware Version 1.91a1
34. Firmware Version 1.91a5

11/02/2006 244 CLARiiON AX150


CLARiiON AX150

35. BIOS 1.05


36. BIOS 1.08
37. This HBA is equivalent to the QLogic QLA2340.
38. BIOS 1.45
39. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
40. Firmware Version 1.91a2
41. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
42. Driver Version 1.10x1
43. Driver Version 9.1.2.15 STORPort Miniport Driver
44. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
45. Driver Version 9.1.2.16 STORPort Miniport Driver
46. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
47. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
48. Driver Version 1.20a3 STORPort Miniport Driver
49. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver to
be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
50. Driver Version 1.11a3
51. Driver Version 1.11a3 STORPort Miniport Driver
52. BIOS 1.16
53. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
54. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
55. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
56. Driver Version 9.0.2.17 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
57. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
58. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
59. Firmware Version 2.50a4
60. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com Requires Microsoft STORPort hotfix
Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently requires Service Pack 1 (SP1) to be installed before the hotfix
can be installed. STORPort Miniport Driver
61. Firmware Version 2.10a9
62. BIOS 1.71a0
63. Internal port(s) on QLogic or McData 4Gb FC switch module(s) must be set to 4Gb to SAN boot.
64. Mixing 2Gb and 4Gb fibre channel expansion cards is not supported in this server.
65. Refer to EMC Knowledgebase ID emc105679 for any special HBA drivers that may be required.
66. Due to the HS20's embedded FC−SW design, array lun masking is required to assign LUNS to each individual blade server.
67. Dual−port FC switch module. Can be used in place of Optical PassThru Module (OPM.)
68. BIOS 1.12
69. RPQ or Unisys Custom Engineering Request (CER) required.
70. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
71. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
72. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
73. BIOS 1.48
74. Driver Version 9.1.2.11
75. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.

Microsoft Windows 2003 [x86]


Where replication of boot LUN is supported, any use of the replicated boot LUN other than in original host may lead to hardware/configuration mismatch that
render the replicated boot LUN unusable. Any issues that arise in trying to use the boot LUN in a host that is non−identical to the source host is outside of the
scope of what EMC can support. Also, in any case due to environment failure where I/O is not written back to the source LUN, or if the source LUN is not left
in a stable state by the source host, the replicated LUN is not guaranteed to be any more usable than the source. Also, there may be specific software
licensing that needs to be investigated when duplicating the boot LUN.

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
1 Unisys ES7000/550 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] DataCenter 100, 131 FC−SW CLARiiON
AX150
2 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
8874)42 [x86] DataCenter LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
13, 18, 58, 60, 61 AX150
3 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 IBM: 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
8874)42 [x86] DataCenter 120, 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−SW CLARiiON
103 AX150
4 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 QLogic QLA2340−E−SP14, 18, 19, 28 FC−AL, EMC Y2, 27 See23
8874)42 [x86] DataCenter FC−SW CLARiiON
AX150
5 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y2
[x86] DataCenter SP111 PCI−X 134, 137 FC−SW CLARiiON
AX150
6 Unisys ES7000/550 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] DataCenter: R21, SP1 100, 142 FC−SW CLARiiON
AX150

11/02/2006 245 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
7 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
8874)42 [x86] DataCenter: R21, SP1 LP1050−E3, 18, 50, 60, 61, 66 , LP1050−E3, FC−SW CLARiiON
6, 18, 56, 60 , LP982−E3, 18, 50, 60, 61, 66 , AX150
LP982−E3, 6, 18, 56, 60
8 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 IBM 19K1246: (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2
8874)42 [x86] DataCenter: R21, SP1 120, (QLA2310)9, 18, 19, 82, 120 ; FC−SW CLARiiON
AX150
IBM 24P0960: (QLA2340)18, 19, 20, 21, 22,
103, (QLA2340)9, 18, 19, 82, 103

9 IBM xSeries x3950/x3950E/x460 (8872, Microsoft Windows 2003 PCI−X105 QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27 See23
8874)42 [x86] DataCenter: R21, SP1 QLA2340−E−SP9, 18, 19, 82 FC−SW CLARiiON
AX150
10 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] DataCenter: R21, 108, 125 FC−SW CLARiiON
SP111 AX150
11 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/540 [x86] DataCenter: R21, 100, 126 FC−SW CLARiiON
SP111 AX150
12 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX: (LP1050)3, FC−AL, EMC Y2
[x86] DataCenter: R21, 123, 127, (LP1050)3, 125 FC−SW CLARiiON
SP111 AX150
13 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y
[x86] DataCenter: R21, 121, 122, 123 FC−SW CLARiiON
SP111; AX150
Microsoft Windows 2003
[x86] Enterprise Edition
SP111
14 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y2
[x86] DataCenter: R21, PCI−X 134, 138 FC−SW CLARiiON
SP111; AX150
Microsoft Windows 2003
[x86]: Enterprise Edition
R21, Standard Edition R21
15 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC Y
[x86] DataCenter: R21, 121, 122 FC−SW CLARiiON
SP111; AX150
Microsoft Windows 2003
[x86]: Enterprise Edition
SP111, Standard Edition
SP111
16 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, 133 FC−AL, EMC Y2
[x86] DataCenter12 FC−SW CLARiiON
AX150
17 Unisys: ES7000/520, ES7000/530, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/540 [x86] DataCenter12 100, 140 FC−SW CLARiiON
AX150
18 NEC Express 5800 320Ma46, 81 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 14, 18, 28, 65, FC−AL, EMC Y2 See23
[x86] Enterprise Edition 80 FC−SW CLARiiON
AX150
19 Stratus ftServer: 430046, 460046 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 18, 28, 65, 80, FC−AL, EMC N See23
[x86] Enterprise Edition 93 FC−SW CLARiiON
AX150
20 Stratus ftServer: 230043, 330038, 430046, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 39, 77, 78 , FC−AL, EMC N See23
460046, 560038, 660038 [x86] Enterprise Edition QLA210−E−SP4, 30, 31, 39 FC−SW CLARiiON
AX150
21 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
BL465c (403433−B21), BL465c [x86] Enterprise Edition Express HP c−Class Bladesystem FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), (403619−B21)29, 71, 72 AX150
BL465c (407235−B21), BL480c
(404704−B21)
22 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 14, 18, 28, 65, FC−AL, EMC Y2 See23
[x86] Enterprise Edition 80 FC−SW CLARiiON
AX150
23 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 14, 18, 28, 65, FC−AL, EMC N See23
[x86] Enterprise Edition 80, 93 FC−SW CLARiiON
AX150
24 Stratus ftServer: 430046, 460046 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 18, 65, 80, 82, FC−AL, EMC N See23
[x86] Enterprise Edition SP1 93 FC−SW CLARiiON
AX150
25 NEC Express 5800 320Ma46, 81 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 9, 18, 65, 80, 82 FC−AL, EMC Y2 See23
[x86] Enterprise Edition SP1 FC−SW CLARiiON
AX150
26 Stratus ftServer 5700 Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 9, 18, 65, 80, 82, FC−AL, EMC N See23
[x86] Enterprise Edition SP1 93 FC−SW CLARiiON
AX150
27 Stratus ftServer: 230043, 330038, 430046, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 44, 77, 78 , FC−AL, EMC N See23
460046, 560038, 660038 [x86] Enterprise Edition SP1 QLA210−E−SP4, 30, 31, 44 FC−SW CLARiiON
AX150
28 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 20, 21, 65, FC−AL, EMC Y2 See23
[x86] Enterprise Edition SP1 80 FC−SW CLARiiON
AX150
29 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 20, 21, 65, FC−AL, EMC N See23
[x86] Enterprise Edition SP1 80, 93 FC−SW CLARiiON
AX150

11/02/2006 246 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
30 Unisys: ES3220, ES3220L Microsoft Windows 2003 PCI, Unisys FCH752313−PCX: (LP1050)3, FC−AL, EMC N
[x86] Enterprise Edition PCI−X 123, 127, (LP1050)3, 60, 123 FC−SW CLARiiON
SP111 AX150
31 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
BL465c (403433−B21), BL465c [x86] Enterprise Edition: Express HP c−Class Bladesystem FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), R21, SP1 (403619−B21)26, 71, 72 AX150
BL465c (407235−B21), BL480c
(404704−B21)
32 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), [x86] Enterprise Edition: HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); R21, SP1; (403619−B21)26, 71, 72 AX150
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x86] Standard: Edition,
Edition R21, Edition SP1
33 NEC Express 5800: 320Mc−R, 340Hb−R Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)9, 18, 19, 22, FC−AL, EMC Y2
[x86] Enterprise Edition: 80, 82 FC−SW CLARiiON
R21, SP111 AX150
34 NEC Express 5800: 320La−R116, 320La116, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)9, 18, 19, 22, FC−AL, EMC Y2
320Lb−R116, 117, 320Lb2−R, 320Lb116, 117, [x86] Enterprise Edition: 80, 82, 115 FC−SW CLARiiON
320Lc, 320Lc−R, 330Ma−R116, 330Mb−R116, R21, SP111 AX150
118, 119, 340Ha−R116, 118, 119

35 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP9, 18, 19, 22, 80, FC−AL, EMC Y2, 27 See23
320Lc−R [x86] Enterprise Edition: 82 FC−SW CLARiiON
R21, SP111 AX150
36 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: 108, 128 FC−SW CLARiiON
R21, SP111 AX150
37 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: 123, 129 FC−SW CLARiiON
R21, SP111 AX150
38 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, 128 FC−AL, EMC Y2
Model 300 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111 AX150
39 Unisys: FS1300, Libra Model 300 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: 100, 123, 129 FC−SW CLARiiON
R21, SP111 AX150
40 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/530, ES7000/540, ES7000/550, [x86] Enterprise Edition: 100, 130 FC−SW CLARiiON
ES7000/560 [32−Bit] R21, SP111 AX150
41 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI Emulex LP101−E3, 18, 49, 50, 60 FC−AL, EMC Y2, 27 See36
DL36034, DL58034, ML350(G2)34, ML35034, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, R21, SP111; AX150
ML530(G3)34, ML53034, ML57034, ML75034;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x340 (4500R), x342, x350 SP111
(6000R), x370
42 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI Emulex LP982−E3, 18, 50, 60, 61, 66 FC−AL, EMC Y2, 27 See36
DL36034, DL58034, ML350(G2)34, ML35034, [x86] Enterprise Edition: FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, R21, SP111; AX150
ML530(G3)34, ML53034, ML57034, ML75034;
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x342, x350 (6000R), x370 SP111
43 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI Emulex: LP101−E3, 6, 18, 56, 60 , FC−AL, EMC Y2, 27 See36
2500, 255040, 4300, 4350, 4400, 6100, 6300, [x86] Enterprise Edition: LP982−E3, 6, 18, 60, 61, 66 FC−SW CLARiiON
6350, 6400, 6450, 8450 R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
44 HPQ Proliant: 850034, DL32034, Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 50, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
DL360(G2)34, DL36034, DL380(G2)34, [x86] Enterprise Edition: LP1150−E3, 4, 18, 49, 50, 61, 75 FC−SW CLARiiON
DL380(G3)34, DL38034, DL58034, R21, SP111; AX150
ML350(G2)34, ML35034, ML370(G2)34,
ML37034, ML530(G2)34, ML530(G3)34, Microsoft Windows 2003
ML53034, ML57034, ML75034; [x86] Standard Edition: R21,
SP111
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
45 Dell PowerEdge: 1550, 2450, 2500, 255040, Microsoft Windows 2003 PCI Emulex: LP1050−E3, 6, 18, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
4400, 6350, 6400, 645097, 8450 [x86] Enterprise Edition: LP1150−E3, 4, 6, 18, 56, 61, 75 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
46 Fujitsu Siemens Primergy: BX60098, BX620 Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q4, 18, 19, FC−AL, EMC Y2
S2F104, BX620 S2104, BX620 S3, BX620104, [x86] Enterprise Edition: 94, 95 FC−SW CLARiiON
BX630 (2−way), BX630 (4−way), BX630 R21, SP111; AX150
(8−way), BX660104
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
47 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI HPQ: A7298A (LP982)3, 18, 49, 50, 60, 61 , FC−AL, EMC Y2
DL36034, DL380(G2)34, DL380(G3)34, [x86] Enterprise Edition: A7388A (LP1050)3, 18, 49, 50, 60, 61 , FC−SW CLARiiON
DL38034, DL58034, ML350(G2)34, ML35034, R21, SP111; AD167A/FC2143 (LP1150)3, 4, 49, 50, 61, AX150
ML370(G2)34, ML37034, ML530(G2)34, 112, FCA2214 (QLA2340)18, 19, 20, 21, 22 ,
ML53034, ML57034, ML75034 Microsoft Windows 2003 FCA2408 (LP982)3, 4, 18, 49, 50, 60, 61
[x86] Standard Edition: R21,
SP111

11/02/2006 247 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
48 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2
x330, x335, x340 (4500R), x342, x350 [x86] Enterprise Edition: 120 FC−SW CLARiiON
(6000R), x370 R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
49 IBM xSeries: x230, x240, x250, x330, x335, Microsoft Windows 2003 PCI IBM 24P0960 (QLA2340)18, 19, 20, 21, 22, FC−AL, EMC Y2
x340 (4500R), x342, x350 (6000R), x370 [x86] Enterprise Edition: 103 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
50 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)4, 18, 22, 65, 74 , FC−AL, EMC Y2, 27 See23
x330, x335, x340 (4500R), x342, x350 [x86] Enterprise Edition: 39M5895 (QLA2462)4, 18, 22, 65, 74 FC−SW CLARiiON
(6000R), x370 R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
51 NEC Express 5800: 120Rd−1, 120Rf−2, Microsoft Windows 2003 PCI NEC N8190−120 (LP1050)3, 6, 18, 55, 56, FC−AL, EMC Y2
140Hd, 140Rc−4, 180Rd−4 [x86] Enterprise Edition: 60, 61 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
52 NEC Express 5800: 320La−R116, 320La116, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)9, 18, 19, 22, FC−AL, EMC Y2
320Lb−R116, 117, 320Lb116, 117 [x86] Enterprise Edition: 82 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
53 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27 See23
DL36034, DL58034, ML350(G2)34, ML35034, [x86] Enterprise Edition: 78, QLA210−E−SP4, 30, 31, 32 , FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, R21, SP111; QLA2340−E−SP18, 19, 20, 21 , AX150
ML530(G3)34, ML53034, ML57034, ML75034; QLA2460−E−SP4, 18, 20, 21, 22, 65
Microsoft Windows 2003
IBM xSeries: x225, x230, x232, x240, x250, [x86] Standard Edition: R21,
x330, x335, x340 (4500R), x342, x350 SP111
(6000R), x370
54 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 76, 79 , FC−AL, EMC Y2, 27 See23
2500, 255040, 4300, 4350, 4400, 6100, 6300, [x86] Enterprise Edition: QLA210−E−SP4, 30, 32, 35 , FC−SW CLARiiON
6350, 6400, 6450, 8450 R21, SP111; QLA2340−E−SP9, 10, 18, 19 , AX150
QLA2460−E−SP4, 18, 21, 65, 106
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
55 Unisys: ES3120, ES3120L, ES3140, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES3140L [x86] Enterprise Edition: 100, 124 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
56 Fujitsu Siemens Primergy: RX200 S2, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 66, 100 FC−AL, EMC Y2, 27, See36
S2, TX600 S2 [x86] Enterprise Edition: Express FC−SW CLARiiON Y2, 27, 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
57 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 6, 15, 18, 37 FC−AL, EMC Y2, 27 See36
2850, 6800, 6850; [x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP111; AX150
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
Fujitsu Siemens Primergy RX300 S3; [x86] Standard Edition: R21,
HPQ Proliant: DL360(G4)34, DL380(G4)34, SP111
DL580(G3)34;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
58 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 6, 15, 18, 37 FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; R21, SP111; AX150
Fujitsu Siemens Primergy RX300 S3; Microsoft Windows 2003
HPQ Proliant: DL360(G4)34, DL380(G4)34, [x86] Standard Edition: R21,
DL580(G3)34; SP111
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
59 Fujitsu Siemens Primergy RX300 S3 Microsoft Windows 2003 PCI Emulex LPe1150−E3, 4, 18, 49, 83 FC−AL, EMC Y2, 27, See36
[x86] Enterprise Edition: Express FC−SW CLARiiON Y2, 27, 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 248 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
60 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express LP1050−E3, 18, 50, 60, 61, 66 , LP1150−E3, FC−SW CLARiiON
R21, SP111; 4, 18, 49, 50, 61, 75 , LP982−E3, 18, 50, 60, AX150
61, 66
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
61 Dell PowerEdge 1950 Microsoft Windows 2003 PCI Emulex: LP1050−E3, 6, 18, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express LP982−E3, 6, 18, 60, 61, 66 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
62 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 18, 50, 60, 61, FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express 66, LPe1150−E3, 4, 7, 18, 49, 50, 61 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; R21, SP111; AX150
HPQ Proliant: DL360(G4)34, DL380(G4)34, Microsoft Windows 2003
DL580(G3)34; [x86] Standard Edition: R21,
SP111
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
63 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 18, 50, 60, 61, FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express 66, LPe1150−E3, 4, 7, 18, 49, 50, 61 FC−SW CLARiiON
HPQ Proliant: DL360(G4)34, DL380(G4)34, R21, SP111; AX150
DL580(G3)34;
Microsoft Windows 2003
LangChao: NC3000, NC3500, NF500, [x86] Standard Edition: R21,
NF520; SP111
Samsung: ZSS230, ZSS230D
64 IBM xSeries x3455 (7984) Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 6, 18, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express LPe1150−E3, 4, 6, 7, 18, 49, 61 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
65 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 6, 18, 60, 61 , FC−AL, EMC Y2, 27 See36
2850, 6800, 6850 [x86] Enterprise Edition: Express LPe1150−E3, 4, 6, 7, 18, 61 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
66 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)3, 4, 18, 49, 50, FC−AL, EMC Y2, Y2,
[x86] Enterprise Edition: Express 61 FC−SW CLARiiON 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
67 HPQ Proliant: DL360(G4)34, DL380(G4)34, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, Y2,
DL580(G3)34 [x86] Enterprise Edition: Express 7, 49, 50, 61 FC−SW CLARiiON 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
68 HPQ Proliant: DL360(G4)34, DL380(G4)34 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)4, FC−AL, EMC Y2, Y2,
[x86] Enterprise Edition: Express 18, 20, 21, 65, 109 FC−SW CLARiiON 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
69 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)3, 6, 7, 55, 56 FC−AL, EMC Y2, 27 See36
120Ri−2, 140Hf, 140Re−4 [x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
70 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)3, 6, 7, 55, 56 FC−AL, EMC Y2, 27, 54 See23, 36
[x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
71 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 32, 76, 77, 78 FC−AL, EMC Y2, 27, 41 See23
[x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
72 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP4, 18, 24, 25, 26 FC−AL, EMC Y2, 27 See23
2850, 6800, 6850; [x86] Enterprise Edition: Express FC−SW CLARiiON
R21, SP111; AX150
Digital Henge INNO: HR−4850, HR−6850;
Microsoft Windows 2003
IBM xSeries x3455 (7984); [x86] Standard Edition: R21,
LangChao: NC3000, NC3500, NF500, SP111
NF520;
Samsung: ZSS230, ZSS230D

11/02/2006 249 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
73 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express 78, QLA200−E−SP18, 30, 76, 79 , FC−SW CLARiiON
R21, SP111; QLA210−E−SP4, 30, 32, 35 , AX150
QLA2340−E−SP9, 10, 18, 19
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
74 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27, See23
[x86] Enterprise Edition: Express QLA2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON Y2, 27, 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
75 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 26 , FC−AL, EMC Y2, 27, 59 See23
[x86] Enterprise Edition: Express QLE2360−E−SP18, 22, 62, 63, 64 , FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; R21, SP111; QLE2460−E−SP4, 18, 20, 21, 22, 65 AX150
LangChao: NC3000, NC3500, NF500, Microsoft Windows 2003
NF520; [x86] Standard Edition: R21,
SP111
Samsung: ZSS150, ZSS230, ZSS230D
76 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 26 , FC−AL, EMC Y2, 27, 41 See23
[x86] Enterprise Edition: Express QLE2360−E−SP18, 22, 62, 63, 64 , FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP111; QLE2460−E−SP4, 18, 20, 21, 22, 65 AX150
NF520;
Microsoft Windows 2003
Samsung: ZSS230, ZSS230D [x86] Standard Edition: R21,
SP111
77 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP18, 22, 62, 63, 64 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express QLE2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP111; AX150
NF520;
Microsoft Windows 2003
Samsung: ZSS230, ZSS230D [x86] Standard Edition: R21,
SP111
78 IBM xSeries x3455 (7984) Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 18, 22, 62, 101 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express QLE2360−E−SP9, 18, 62, 101, 106 , FC−SW CLARiiON
R21, SP111; QLE2460−E−SP4, 9, 18, 21, 22, 65 , AX150
QLE2460−E−SP4, 9, 18, 21, 65, 106
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
79 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP9, 10, 18, 62 , FC−AL, EMC Y2, 27 See23
2850, 6800, 6850 [x86] Enterprise Edition: Express QLE2460−E−SP4, 9, 10, 18, 65 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
80 IBM eServer 326m (Model 7969) Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 60, 61, 66 FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
81 IBM: eServer 326m (Model 7969), xSeries Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 60, 61, 66 FC−AL, EMC Y2, 27 See36
x3550 (7978), xSeries x3650 (7979), xSeries [x86] Enterprise Edition: Express, FC−SW CLARiiON
x3755 (8877) R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
82 Fujitsu Siemens Primergy: RX220, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 66, 100 FC−AL, EMC Y2, 27, See36
S3, TX600 S3 [x86] Enterprise Edition: Express, FC−SW CLARiiON Y2, 27, 59
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
83 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LP1150−E3, 4, 18, 49, 50, 61, 75 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), R21, SP111; PCI−X AX150
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP111
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 250 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
84 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 6, 15, 18, 37 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; R21, SP111; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x86] Standard Edition: R21,
SP111
Fujitsu Siemens Primergy: RX200 S3,
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
85 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 6, 15, 18, 37 FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S3, R21, SP111; PCI−X AX150
RX220, RX600 S3, TX300 S3, TX600 S3;
Microsoft Windows 2003
IBM eServer 326m (Model 7969); [x86] Standard Edition: R21,
Intel: SC5300AF2, SE7520BB2, SP111
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
86 Fujitsu Siemens Primergy: RX200 S3, Microsoft Windows 2003 PCI Emulex LPe1150−E3, 4, 18, 49, 83 FC−AL, EMC Y2, 27, See36
RX220, RX600 S3, TX300 S3, TX600 S3 [x86] Enterprise Edition: Express, FC−SW CLARiiON Y2, 27, 59
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
87 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, LP1050−E3, 18, 50, 60, 61, 66 , LP982−E3, FC−SW CLARiiON
IBM xSeries: x336 (8837)45,x346 (8840)45, R21, SP111; PCI−X 18, 50, 60, 61, 66 AX150
x3550 (7978), x3650 (7979), x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP111
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
88 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27, 41 See36
x3755 (8877) [x86] Enterprise Edition: Express, LP1050−E3, 18, 50, 60, 61, 66 , LP982−E3, FC−SW CLARiiON
R21, SP111; PCI−X 18, 50, 60, 61, 66 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
89 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E3, 18, 49, 60 , FC−AL, EMC Y2, 27 See36
x3755 (8877) [x86] Enterprise Edition: Express, LP1050−E3, 18, 60, 61, 66 , LP1150−E3, 4, FC−SW CLARiiON
R21, SP111; PCI−X 18, 49, 61, 75 , LP982−E3, 18, 60, 61, 66 , AX150
LPe1150−E3, 4, 7, 18, 49, 61
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
90 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050−E3, 6, 18, 60, 61, 66 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, LP1050Ex−E3, 4, 6, 18, 60, 61 , LP982−E3, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP111; PCI−X 6, 18, 60, 61, 66 , LPe1150−E3, 4, 6, 7, 18, 61 AX150
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x86] Standard Edition: R21,
SR2500/S5000PAL; SP111
Samsung ZSS132
91 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 18, 50, 60, 61, FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express, 66, LPe1150−E3, 4, 7, 18, 49, 50, 61 FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP111; PCI−X AX150
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x86] Standard Edition: R21,
SR4850HW4/SR6850HW4; SP111
Lenovo SureServer: R630 G5, R650, R650
G5, T650
92 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 18, 50, 60, 61, FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, 66, LPe1150−E3, 4, 7, 18, 49, 50, 61 FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP111; PCI−X AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x86] Standard Edition: R21,
Lenovo SureServer: R630 G5, R650, R650 SP111
G5, T650

11/02/2006 251 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
93 HPQ Proliant ML350(G4)34 Microsoft Windows 2003 PCI HPQ: AB429A/FC1143 (QLA2460)4, 18, FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, 20, 65, AE369A/FC1243 (QLA2462)4, 18, FC−SW CLARiiON
R21, SP111; PCI−X 20, 65 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
94 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2, 41
[x86] Enterprise Edition: Express, 120 FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
95 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 18, 19, 20, 21 FC−AL, EMC Y2
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
96 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 18, 19, 20, 21 FC−AL, EMC Y2, 27, See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON Y2, 27, 41
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
97 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 18, 19, 20, 21 FC−AL, EMC Y2, 27, See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON Y2, 27, 41
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
98 IBM xSeries: x336 (8837)45, x346 (8840)45, Microsoft Windows 2003 PCI IBM: 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2
x3550 (7978), x3650 (7979) [x86] Enterprise Edition: Express, 120, 24P0960 (QLA2340)18, 19, 20, 21, 22, FC−SW CLARiiON
R21, SP111; PCI−X 103 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
99 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)4, 18, 22, 65, 74 , FC−AL, EMC Y2, 27 See23
x3755 (8877) [x86] Enterprise Edition: Express, 39M5895 (QLA2462)4, 18, 22, 65, 74 ; FC−SW CLARiiON
R21, SP111; PCI−X AX150
QLogic: QLA2340−E−SP18, 19, 21,
Microsoft Windows 2003 QLA2460−E−SP4, 18, 21, 22, 65 ,
1
[x86] Standard Edition: R2 , QLE2460−E−SP4, 18, 21, 22, 65 ,
SP111 QLE2460−E−SP4, 18, 21, 65, 106
100 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 32, 76, 77, 78 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP111; PCI−X AX150
AS2500;
Microsoft Windows 2003
IBM xSeries: x336 (8837)45, x346 (8840)45, [x86] Standard Edition: R21,
x3550 (7978), x3650 (7979), x3755 (8877); SP111
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
101 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 32, 76, 77, 78 FC−AL, EMC Y2, 27, 41 See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP111; PCI−X AX150
AS2500;
Microsoft Windows 2003
IBM xSeries: x3550 (7978), x3650 (7979), [x86] Standard Edition: R21,
x3755 (8877); SP111
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
102 IBM xSeries: x336 (8837)45, x346 (8840)45, Microsoft Windows 2003 PCI QLogic QLA210−E−SP4, 30, 31, 32 FC−AL, EMC Y2, 27 See23
x3550 (7978), x3650 (7979), x3755 (8877) [x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
103 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2340−E−SP18, 19, 20, 21 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)45, x346 (8840)45, R21, SP111; PCI−X AX150
x3550 (7978), x3650 (7979), x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP111
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
104 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 18, 20, 21, 22, FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, 65 FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), R21, SP111; PCI−X AX150
x3755 (8877);
Microsoft Windows 2003
Intel: SC5300AF2, SE7520BB2, [x86] Standard Edition: R21,
SR1400/SE7520JR2, SR2400/SE7520JR2, SP111
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 252 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
105 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP4, 18, 24, 25, 26 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; R21, SP111; PCI−X AX150
Digital Henge Revo: AS1500, AS1550, Microsoft Windows 2003
AS2500; [x86] Standard Edition: R21,
SP111
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
106 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 76, 79 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, QLA210−E−SP4, 30, 32, 35 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP111; PCI−X AX150
AS2500;
Microsoft Windows 2003
IBM xSeries: x3550 (7978), x3650 (7979), [x86] Standard Edition: R21,
x3755 (8877); SP111
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
107 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic: QLA210−E−SP4, 30, 31, 32 , FC−AL, EMC Y2, 27, 41 See23
x3755 (8877) [x86] Enterprise Edition: Express, QLA2340−E−SP18, 19, 20, 21 FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
108 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27, 59 See23
[x86] Enterprise Edition: Express, QLA2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, R21, SP111; PCI−X AX150
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M, Microsoft Windows 2003
SR4850HW4/SR6850HW4; [x86] Standard Edition: R21,
SP111
Lenovo SureServer: R630 G5, R650, R650
G5, T650
109 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP9, 10, 18, 19 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, QLE2360−E−SP9, 10, 18, 62 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, R21, SP111; PCI−X QLE2460−E−SP4, 9, 10, 18, 65 AX150
AS2500;
Microsoft Windows 2003
Intel: SR1500/S5000PAL, [x86] Standard Edition: R21,
SR2500/S5000PAL; SP111
Samsung ZSS132
110 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 26 , FC−AL, EMC Y2, 27, 59 See23
[x86] Enterprise Edition: Express, QLE2360−E−SP18, 22, 62, 63, 64 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP111; PCI−X QLE2460−E−SP4, 18, 20, 21, 22, 65 AX150
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2, Microsoft Windows 2003
SR4850HW4−M/SR6850HW4−M, [x86] Standard Edition: R21,
SR4850HW4/SR6850HW4; SP111
Lenovo SureServer: R630 G5, R650, R650
G5, T650
111 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 26 , FC−AL, EMC Y2, 27, 41 See23
[x86] Enterprise Edition: Express, QLE2360−E−SP18, 22, 62, 63, 64 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP111; PCI−X QLE2460−E−SP4, 18, 20, 21, 22, 65 AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x86] Standard Edition: R21,
Lenovo SureServer: R630 G5, R650, R650 SP111
G5, T650
112 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP18, 22, 62, 63, 64 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, QLE2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON
IBM eServer 326m (Model 7969); R21, SP111; PCI−X AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4; Microsoft Windows 2003
[x86] Standard Edition: R21,
Lenovo SureServer: R630 G5, R650, R650 SP111
G5, T650
113 IBM xSeries: x346 (8840)45, x3550 (7978), Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP18, 22, 62, 63 , FC−AL, EMC Y2, 27 See23
x3650 (7979), x3755 (8877) [x86] Enterprise Edition: Express, QLE2360−E−SP18, 62, 63, 106 FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
114 Dell PowerEdge 6850 Microsoft Windows 2003 PCI−X Dell 2362M9, 10, 69, 70 FC−AL, EMC Y2
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 253 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
115 Dell PowerEdge 1855 Microsoft Windows 2003 PCI−X Dell: 2342M9, 10, 18, 19 , LPe1105−M3, 4, FC−AL, EMC Y2
[x86] Enterprise Edition: 5, 6, 7, QME24624, 8, 9, 10 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
116 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex LP1150−E3, 4, 6, 18, 56, 61, 75 FC−AL, EMC Y2, 27 See36
2650, 4600, 6600, 6650 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
117 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
SH4500; [x86] Enterprise Edition: LP1050−E3, 18, 50, 60, 61, 66 , LP1150−E3, FC−SW CLARiiON
R21, SP111; 4, 18, 49, 50, 61, 75 , LP982−E3, 18, 50, 60, AX150
HPQ Proliant: BL40p, DL360(G3)34, 61, 66
DL360(G4)34, DL56034, DL74034, DL760 Microsoft Windows 2003
(G2)34, DL76034, ML570(G2)34; [x86] Standard Edition: R21,
SP111
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
118 IBM xSeries x3850/x366 (8863)42 Microsoft Windows 2003 PCI−X Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27, 41 See36
[x86] Enterprise Edition: LP1050−E3, 18, 50, 60, 61, 66 , LP982−E3, FC−SW CLARiiON
R21, SP111; 18, 50, 60, 61, 66 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
119 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex: LP101−E3, 6, 18, 56, 60 , FC−AL, EMC Y2, 27 See36
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86] Enterprise Edition: LP1050−E3, 6, 18, 60, 61, 66 , LP982−E3, 6, FC−SW CLARiiON
6850 R21, SP111; 18, 60, 61, 66 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
120 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X Emulex: LP1050Ex−E3, 4, 18, 50, 60, 61, FC−AL, EMC Y2, 27, See36
[x86] Enterprise Edition: 66, LPe111−E3, 4, 6, 15, 18, 37 , FC−SW CLARiiON Y2, 27, 59
R21, SP111; LPe1150−E3, 4, 7, 18, 49, 50, 61 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
121 NEC Express 5800: 140Hf, 140Re−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E3, 4, 6, 15, 18, 37 , FC−AL, EMC Y2
[x86] Enterprise Edition: LPe1150−E3, 4, 6, 7, 56 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
122 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E3, 4, 6, 15, 18, 37 , FC−AL, EMC Y2, 27, 54 See23, 36
[x86] Enterprise Edition: LPe1150−E3, 4, 6, 7, 56 ; FC−SW CLARiiON
R21, SP111; AX150
NEC N8190−120 (LP1050)3, 6, 18, 55, 56,
Microsoft Windows 2003 60, 61
[x86] Standard Edition: R21,
SP111
123 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ AE311A/FC1142SR (QLE2460)4, FC−AL, EMC Y2, 41
[x86] Enterprise Edition: 18, 20, 21, 65, 109 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
124 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86] Enterprise Edition: for HP Proliant BL25p/BL45p FC−SW CLARiiON
R21, SP111; 381881−B2118, 20, 21, 22, 102 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
125 HPQ Proliant: DL360(G3)34, DL360(G4)34, Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)3, 18, 49, 50, 60, 61 , FC−AL, EMC Y2
DL56034, DL74034, DL760 (G2)34, DL76034, [x86] Enterprise Edition: A7388A (LP1050)3, 18, 49, 50, 60, 61 , FC−SW CLARiiON
ML570(G2)34 R21, SP111; AD167A/FC2143 (LP1150)3, 4, 49, 50, 61, AX150
112, FCA2214 (QLA2340)18, 19, 20, 21, 22 ,
Microsoft Windows 2003 FCA2408 (LP982)3, 4, 18, 49, 50, 60, 61
[x86] Standard Edition: R21,
SP111
126 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, Y2,
[x86] Enterprise Edition: 7, 49, 50, 61 , AE311A/FC1142SR FC−SW CLARiiON 59
R21, SP111; (QLE2460)4, 18, 20, 21, 65, 109 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 254 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
127 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 18, FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: 20, 65, AE369A/FC1243 (QLA2462)4, 18, FC−SW CLARiiON
R21, SP111; 20, 65; AX150
Microsoft Windows 2003 QLogic: QLE220−E−SP4, 18, 24, 25, 26 ,
[x86] Standard Edition: R21, QLE2360−E−SP18, 22, 62, 63, 64 ,
SP111 QLE2460−E−SP4, 18, 20, 21, 22, 65
128 IBM xSeries x3850/x366 (8863)42 Microsoft Windows 2003 PCI−X IBM 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2, 41
[x86] Enterprise Edition: 120 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
129 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2
[x86] Enterprise Edition: 120,24P0960 (QLA2340)18, 19, 20, 21, 22, FC−SW CLARiiON
R21, SP111; 103 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
130 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 39M5894 (QLA2460)4, 18, 22, 65, 74 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: 39M5895 (QLA2462)4, 18, 22, 65, 74 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
131 NEC Express 5800: 110Rg−1, 120Lh, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)3, 6, 18, 55, 56, FC−AL, EMC Y2
120Re−1, 120Rg−2, 180Re−3 [x86] Enterprise Edition: 60, 61 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
132 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)3, 6, 18, 55, 56, FC−AL, EMC Y2, 27 See36
120Ri−2, 140Hf, 140Re−4 [x86] Enterprise Edition: 60, 61 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
133 NEC Express 5800: 120Rf−1, 120Rh−2 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)3, 6, 18, 55, 56, FC−AL, EMC Y2, 27
[x86] Enterprise Edition: 60, 61 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
134 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP18, 19, 20, 21 FC−AL, EMC Y2, 27, 59 See23
[x86] Enterprise Edition: FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP111; AX150
NF520;
Microsoft Windows 2003
Samsung ZSS150 [x86] Standard Edition: R21,
SP111
135 Fujitsu Siemens Primergy RX200 Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP18, 19, 94 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
136 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 20, 21, 22, FC−AL, EMC Y2, 27, 59 See23
[x86] Enterprise Edition: 65 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, R21, SP111; AX150
NF520;
Microsoft Windows 2003
Samsung ZSS150; [x86] Standard Edition: R21,
Sun: x4100, x4200 SP111
137 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 21, 22, 65 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
138 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 21, 65, 106 FC−AL, EMC Y2, 27 See23
2650, 4600, 6600, 6650; [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Sun: x4100, x4200
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
139 Digital Henge INNO SH4500; Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27 See23
HPQ Proliant: BL40p, DL360(G3)34, [x86] Enterprise Edition: 78, QLA210−E−SP4, 30, 31, 32 FC−SW CLARiiON
DL360(G4)34, DL56034, DL74034, DL760 R21, SP111; AX150
(G2)34, DL76034, ML570(G2)34;
Microsoft Windows 2003
IBM xSeries: x235, x255, x360, x365, x440; [x86] Standard Edition: R21,
SP111
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun: V20z, V40z, x4100, x4200

11/02/2006 255 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
140 IBM xSeries x3850/x366 (8863)42 Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27, 41 See23
[x86] Enterprise Edition: 78, QLA210−E−SP4, 30, 31, 32 , FC−SW CLARiiON
R21, SP111; QLA2340−E−SP18, 19, 20, 21 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
141 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 76, 79 , FC−AL, EMC Y2, 27 See23
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86] Enterprise Edition: QLA210−E−SP4, 30, 32, 35 , FC−SW CLARiiON
6850 R21, SP111; QLA2340−E−SP9, 10, 18, 19 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
142 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27 See23
SH4500; [x86] Enterprise Edition: QLA2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON
R21, SP111; AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)34, Microsoft Windows 2003
DL360(G4)34, DL56034, DL74034, DL760 [x86] Standard Edition: R21,
(G2)34, DL76034, ML570(G2)34; SP111
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
143 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X QLogic: QLE220−E−SP4, 18, 24, 25, 26 , FC−AL, EMC Y2, 27, See23
[x86] Enterprise Edition: QLE2360−E−SP18, 22, 62, 63, 64 , FC−SW CLARiiON 41, Y2,
R21, SP111; QLE2460−E−SP4, 18, 20, 21, 22, 65 AX150 27, 59

Microsoft Windows 2003


[x86] Standard Edition: R21,
SP111
144 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27, 41 See36
[x86] Enterprise Edition: LP1050−E3, 18, 50, 60, 61, 66 , LP982−E3, FC−SW CLARiiON
R21, SP111; 18, 50, 60, 61, 66 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
145 IBM xSeries: x3800/x260 (8865)42, Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
x3950/x3950E/x460 (8872, 8874)42 [x86] Enterprise Edition: LP1050−E3, 18, 50, 60, 61, 66 , LP982−E3, FC−SW CLARiiON
R21, SP111; 18, 50, 60, 61, 66 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
146 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 IBM 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2, 41
[x86] Enterprise Edition: 120 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
147 IBM xSeries: x3800/x260 (8865)42, Microsoft Windows 2003 PCI−X105 IBM: 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2
x3950/x3950E/x460 (8872, 8874)42 [x86] Enterprise Edition: 120, 24P0960 (QLA2340)18, 19, 20, 21, 22, FC−SW CLARiiON
R21, SP111; 103 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
148 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 QLogic QLA2340−E−SP18, 19, 20, 21 FC−AL, EMC Y2, 27, 41 See23
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
149 IBM xSeries: x3800/x260 (8865)42, Microsoft Windows 2003 PCI−X105 QLogic QLA2340−E−SP18, 19, 20, 21 FC−AL, EMC Y2, 27 See23
x3950/x3950E/x460 (8872, 8874)42 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
150 HPQ Proliant BL20p (G2) Microsoft Windows 2003 PCI−X48 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86] Enterprise Edition: for HP Proliant BL20p (G2) FC−SW CLARiiON
R21, SP111; 300874−B2118, 20, 21, 22, 47 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
151 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X48 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86] Enterprise Edition: for HP Proliant BL25p/BL45p FC−SW CLARiiON
R21, SP111; 381881−B2118, 20, 21, 22, 102 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 256 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
152 HPQ Proliant BL30p Microsoft Windows 2003 PCI−X48 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86] Enterprise Edition: for HP Proliant BL30p/BL35p FC−SW CLARiiON
R21, SP111; 354054−B219, 18, 47 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
153 HPQ Proliant BL20p: (G3), (G4) Microsoft Windows 2003 PCI−X48 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86] Enterprise Edition: for HP Proliant BL20p (G3) FC−SW CLARiiON
R21, SP111; 361426−B2118, 20, 21, 22, 47 , AX150
Emulex−based BL20p (G3) Fibre
Microsoft Windows 2003 Channel Mezzanine HBA −
[x86] Standard Edition: R21, 394757−B213, 18, 49, 50, 51, 52
SP111
154 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X99 Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: LP1050−E3, 18, 50, 60, 61, 66 , LP1150−E3, FC−SW CLARiiON
R21, SP111; 4, 18, 49, 50, 61, 75 , LP982−E3, 18, 50, 60, AX150
61, 66
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
155 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X99 QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27, See23
[x86] Enterprise Edition: QLA2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON Y2, 27, 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
156 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M9, 10, 18, 19 , LPe1105−M3, 4, FC−AL, EMC Y2
[x86] Enterprise Edition: Express, 5, 6, 7, QME24624, 8, 9, 10 FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
157 HPQ Proliant DL380(G4)34 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E3, 4, 18, 50, 60, 61, 66 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
158 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LP1150−E3, 4, 18, 49, 50, 61, 75 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
159 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E3, 4, 6, 15, 18, 37 FC−AL, EMC Y2, 27 See36
HPQ Proliant DL380(G4)34 [x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
160 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 18, 49, 83 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
161 HPQ Proliant: DL380(G4)34, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 7, 18, 49, 50, 61 FC−AL, EMC Y2, 27 See36
DL580(G4) [x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
162 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 7, 18, 49, 50, 61 FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
163 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E3, 4, 6, 15, 18, 37 , FC−AL, EMC Y2, 27, 59 See36
[x86] Enterprise Edition: Express, LPe1150−E3, 4, 18, 49, 83 FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
164 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2
[x86] Enterprise Edition: Express, 7, 49, 50, 61 , AD167A/FC2143 (LP1150)3, FC−SW CLARiiON
R21, SP111; PCI−X 4, 49, 50, 61, 112 , AE311A/FC1142SR AX150
(QLE2460)4, 18, 20, 21, 65, 109
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
165 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, 59
[x86] Enterprise Edition: Express, 7, 49, 50, 61 , AE311A/FC1142SR FC−SW CLARiiON
R21, SP111; PCI−X (QLE2460)4, 18, 20, 21, 65, 109 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 257 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
166 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, 18, FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, 20, 65, AE369A/FC1243 (QLA2462)4, 18, FC−SW CLARiiON
R21, SP111; PCI−X 20, 65; AX150
Microsoft Windows 2003 QLogic QLA2460−E−SP4, 18, 20, 21, 22,
[x86] Standard Edition: R21, 65
SP111
167 HPQ Proliant DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP4, 18, 24, 25, 26 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
168 HPQ Proliant: DL380(G4)34, DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP18, 22, 62, 63, 64 FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: Express, FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
169 HPQ Proliant: DL380(G4)34, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP4, 18, 20, 21, 22, FC−AL, EMC Y2, 27 See23
DL580(G3)34, DL580(G4) [x86] Enterprise Edition: Express, 65 FC−SW CLARiiON
R21, SP111; PCI−X AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
170 HPQ Proliant: DL380(G5), DL580(G3)34, Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP4, 18, 20, 21, 22, FC−AL, EMC Y2, 27, See23
DL580(G4) [x86] Enterprise Edition: Express, 65 FC−SW CLARiiON 41, Y2,
R21, SP111; PCI−X AX150 27, 59

Microsoft Windows 2003


[x86] Standard Edition: R21,
SP111
171 HPQ Proliant DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic: QLE220−E−SP4, 18, 24, 25, 26 , FC−AL, EMC Y2, 27, See23
[x86] Enterprise Edition: Express, QLE2360−E−SP18, 22, 62, 63, 64 FC−SW CLARiiON 41, Y2,
R21, SP111; PCI−X AX150 27, 59

Microsoft Windows 2003


[x86] Standard Edition: R21,
SP111
172 Fujitsu Siemens Primergy: RX600, TX600 Microsoft Windows 2003 PCI, Emulex LP1050−E3, 18, 66, 100 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: PCI−X FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
173 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27 See36
DL380(G3)34, DL380(G4)34, DL38034, [x86] Enterprise Edition: PCI−X LP1050−E3, 18, 50, 60, 61, 66 , LP1150−E3, FC−SW CLARiiON
DL38534, DL580(G2)34, DL580(G3)34, R21, SP111; 4, 18, 49, 50, 61, 75 , LP982−E3, 18, 50, 60, AX150
DL58534, ML350(G3)34, ML370(G3)34, 61, 66
ML370(G4)34; Microsoft Windows 2003
[x86] Standard Edition: R21,
IBM: eServer 325 (Model 8835), xSeries x345 SP111
(8670), xSeries x445 (8870);
Samsung SS140
174 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, Emulex: LP101−E3, 6, 18, 56, 60 , FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: PCI−X LP1050−E3, 6, 18, 60, 61, 66 , LP982−E3, 6, FC−SW CLARiiON
R21, SP111; 18, 60, 61, 66 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
175 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)3, 18, 49, 50, 60, 61 , FC−AL, EMC Y2
DL380(G3)34, DL380(G4)34, DL38034, [x86] Enterprise Edition: PCI−X A7388A (LP1050)3, 18, 49, 50, 60, 61 , FC−SW CLARiiON
DL38534, DL580(G2)34, DL58534, R21, SP111; AD167A/FC2143 (LP1150)3, 4, 49, 50, 61, AX150
ML350(G3)34, ML370(G3)34, ML370(G4)34 112, FCA2214 (QLA2340)18, 19, 20, 21, 22 ,
Microsoft Windows 2003 FCA2408 (LP982)3, 4, 18, 49, 50, 60, 61
[x86] Standard Edition: R21,
SP111
176 HPQ Proliant: DL380(G4)34, DL38534, Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)4, 18, FC−AL, EMC Y2, 27 See23
DL58534, ML370(G4)34 [x86] Enterprise Edition: PCI−X 20, 65, AE369A/FC1243 (QLA2462)4, 18, FC−SW CLARiiON
R21, SP111; 20, 65 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
177 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM 19K1246 (QLA2310)18, 19, 20, 21, 22, FC−AL, EMC Y2
(8670), xSeries x445 (8870) [x86] Enterprise Edition: PCI−X 120 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
178 IBM xSeries: x345 (8670), x445 (8870) Microsoft Windows 2003 PCI, IBM 24P0960 (QLA2340)18, 19, 20, 21, 22, FC−AL, EMC Y2
[x86] Enterprise Edition: PCI−X 103 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 258 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
179 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM: 39M5894 (QLA2460)4, 18, 22, 65, 74 , FC−AL, EMC Y2, 27 See23
(8670), xSeries x445 (8870) [x86] Enterprise Edition: PCI−X 39M5895 (QLA2462)4, 18, 22, 65, 74 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
180 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP18, 19, 94 FC−AL, EMC Y2, 27 See23
TX600 [x86] Enterprise Edition: PCI−X FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
181 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27 See23
DL380(G3)34, DL380(G4)34, DL38034, [x86] Enterprise Edition: PCI−X 78, QLA210−E−SP4, 30, 31, 32 , FC−SW CLARiiON
DL38534, DL580(G2)34, DL580(G3)34, R21, SP111; QLA2340−E−SP18, 19, 20, 21 , AX150
DL58534, ML350(G3)34, ML370(G3)34, QLA2460−E−SP4, 18, 20, 21, 22, 65
ML370(G4)34; Microsoft Windows 2003
[x86] Standard Edition: R21,
IBM: eServer 325 (Model 8835), xSeries x345 SP111
(8670), xSeries x445 (8870);
Samsung SS140
182 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 76, 79 , FC−AL, EMC Y2, 27 See23
[x86] Enterprise Edition: PCI−X QLA210−E−SP4, 30, 32, 35 , FC−SW CLARiiON
R21, SP111; QLA2340−E−SP9, 10, 18, 19 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
183 Unisys ES7000/460 [32−Bit] Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition: PCI−X 100, 130 FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
184 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E3, 4, 18, 49, 61, 75 FC−AL, EMC Y2, 27 See36
[x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111;
Microsoft Windows 2003
[x86] Storage Server:
Enterprise Edition R2, R2
185 Fujitsu Siemens Primergy: RX200, RX300, Microsoft Windows 2003 PCI−X Emulex LP1050−E3, 18, 66, 100 FC−AL, EMC Y2, 27 See36
TX200, TX300 [x86] Enterprise Edition: FC−SW CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111;
Microsoft Windows 2003
[x86] Storage: Server,
Server Enterprise Edition,
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
186 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y2
[x86] Enterprise Edition: Fibre Channel Mezzanine HBA − FC−SW CLARiiON
R21, SP111; 394588−B213, 18, 51, 52, 66 AX150
Microsoft Windows 2003
[x86]: Enterprise Edition12,
Standard Edition R21,
Standard Edition SP111,
Standard Edition12
187 HPQ Proliant: BL25p, BL30p Microsoft Windows 2003 PCI−X48 HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y2
[x86] Enterprise Edition: Fibre Channel Mezzanine HBA − FC−SW CLARiiON
R21, SP111; 394588−B213, 18, 51, 52, 66 AX150
Microsoft Windows 2003
[x86]: Enterprise Edition12,
Standard Edition R21,
Standard Edition SP111,
Standard Edition12
188 NEC Express 5800: 320Mc−R, 340Hb−R Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)14, 18, 19, FC−AL, EMC Y2
[x86] Enterprise Edition12 22, 28, 80 FC−SW CLARiiON
AX150
189 NEC Express 5800: 320La−R116, 320La116, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)14, 18, 19, FC−AL, EMC Y2
320Lb−R116, 117, 320Lb2−R, 320Lb116, 117, [x86] Enterprise Edition12 22, 28, 80, 115 FC−SW CLARiiON
320Lc, 320Lc−R, 330Ma−R116, 330Mb−R116, AX150
118, 119, 340Ha−R116, 118, 119

190 NEC Express 5800: 320Lb2−R, 320Lc, Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP14, 18, 19, 22, 28, FC−AL, EMC Y2, 27 See23
320Lc−R [x86] Enterprise Edition12 80 FC−SW CLARiiON
AX150
191 Unisys: EA1400, FS1300, FS1400, Libra Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, 133 FC−AL, EMC Y2
Model 300 [x86] Enterprise Edition12 FC−SW CLARiiON
AX150

11/02/2006 259 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
192 Unisys: FS1300, Libra Model 300 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86] Enterprise Edition12 100, 123, 132 FC−SW CLARiiON
AX150
193 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/530, ES7000/540, ES7000/550, [x86] Enterprise Edition12 100, 131 FC−SW CLARiiON
ES7000/560 [32−Bit] AX150
194 HPQ Proliant: BL460c (404664−B21), Microsoft Windows 2003 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
BL465c (403433−B21), BL465c [x86] Enterprise: Edition, Express for HP c−Class Bladesystem FC−SW CLARiiON
(403434−B21), BL465c (407234−B21), Edition R21, Edition SP1 (403621−B21)3, 15, 16 AX150
BL465c (407235−B21), BL480c
(404704−B21)
195 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
(416654−B21), (416655−B21), [x86] Enterprise: Edition, for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); Edition R21, Edition SP1; (403621−B21)3, 15, 16 AX150
HPQ Proliant BL480c: (416666−B21), Microsoft Windows 2003
(416667−B21), (416668−B21), (416669−B21) [x86] Standard: Edition,
Edition R21, Edition SP1
196 Stratus ftServer 230043 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 39, 77, 78 , FC−AL, EMC N See23
[x86] Standard Edition QLA210−E−SP4, 30, 31, 39 FC−SW CLARiiON
AX150
197 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(403434−B21), (407234−B21), [x86] Standard Edition Express HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21); (403619−B21)29, 71, 72 AX150
HPQ Proliant BL480c (404704−B21)
198 Stratus ftServer 230043 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 44, 77, 78 , FC−AL, EMC N See23
[x86] Standard Edition SP1 QLA210−E−SP4, 30, 31, 44 FC−SW CLARiiON
AX150
199 NEC Express 5800: 320La−R116, 320La116, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)9, 18, 19, 22, FC−AL, EMC Y2
320Lb−R116, 117, 320Lb2−R, 320Lb116, 117, [x86] Standard Edition: R21, 80, 82, 115 FC−SW CLARiiON
330Ma−R116, 330Mb−R116, 118, 119 , SP111 AX150
340Ha−R116, 118, 119
200 NEC Express 5800 320Lb2−R Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP9, 18, 19, 22, 80, FC−AL, EMC Y2, 27 See23
[x86] Standard Edition: R21, 82 FC−SW CLARiiON
SP111 AX150
201 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/530, ES7000/540 [x86] Standard Edition: R21, 100, 130 FC−SW CLARiiON
SP111 AX150
202 NEC Express 5800: 320La−R116, 320La116, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)14, 18, 19, FC−AL, EMC Y2
320Lb−R116, 117, 320Lb2−R, 320Lb116, 117, [x86] Standard Edition12 22, 28, 80, 115 FC−SW CLARiiON
330Ma−R116, 330Mb−R116, 118, 119 , AX150
340Ha−R116, 118, 119
203 NEC Express 5800 320Lb2−R Microsoft Windows 2003 PCI QLogic QLA2310F−E−SP14, 18, 19, 22, 28, FC−AL, EMC Y2, 27 See23
[x86] Standard Edition12 80 FC−SW CLARiiON
AX150
204 Unisys: ES7000/510, ES7000/520, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES7000/530, ES7000/540 [x86] Standard Edition12 100, 131 FC−SW CLARiiON
AX150
205 HPQ Proliant BL465c: (403433−B21), Microsoft Windows 2003 PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(403434−B21), (407234−B21), [x86] Standard: Edition, Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21); Edition R21, Edition SP1 (403621−B21)3, 15, 16, QLogic QMH2462 AX150
4Gb FC HBA for HP c−Class
HPQ Proliant BL480c (404704−B21) Bladesystem (403619−B21)26, 71, 72
206 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E3, 4, 18, 49, 61, 75 FC−AL, EMC Y27 See36
[x86] Storage Server: FC−SW CLARiiON
Enterprise Edition R2, R2 AX150
207 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 21, 65, 111 FC−AL, EMC Y2, 27, See23
[x86] Storage Server: FC−SW CLARiiON Y27
Enterprise Edition R2, R2 AX150
208 Dell PowerVault: 750N, 755N40, 770N, 775N Microsoft Windows 2003 PCI Emulex: LP1050−E3, 6, 18, 60, 61, 113 , FC−AL, EMC N See36
[x86] Storage Server: LP1150−E3, 4, 6, 18, 56, 61, 75 FC−SW CLARiiON
Enterprise Edition SP1, SP1 AX150
209 Dell PowerVault: 750N, 755N40, 770N, 775N Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 60, 61, 66 , FC−AL, EMC N See36
[x86] Storage: Server, LP1150−E3, 4, 18, 49, 61, 75 FC−SW CLARiiON
Server Enterprise Edition AX150
210 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E3, 4, 18, 49, 50, 61, 75 FC−AL, EMC Y2, 27, See36
[x86] Storage: Server, FC−SW CLARiiON Y27
Server Enterprise Edition, AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
211 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 20, 21, 22, FC−AL, EMC Y2, 27, See23
[x86] Storage: Server, 65 FC−SW CLARiiON Y27
Server Enterprise Edition, AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
212 Fujitsu Siemens Primergy: RX200, RX300, Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27 See23
TX200, TX300 [x86] Storage: Server, 78, QLA200−E−SP4, 18, 30, 32, 76, 77, 78 , FC−SW CLARiiON
Server Enterprise Edition, QLA210−E−SP4, 30, 31, 32 AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1

11/02/2006 260 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
213 Fujitsu Siemens FibreCAT N40i Microsoft Windows 2003 PCI, Emulex LP1050−E3, 18, 50, 60, 61, 66, 108 FC−AL, EMC Y2, 27 See36
[x86] Storage: Server, PCI−X FC−SW CLARiiON
Server Enterprise Edition, AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
214 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, Emulex LP1050−E3, 18, 66, 100 FC−AL, EMC Y2, 27 See36
TX600 [x86] Storage: Server, PCI−X FC−SW CLARiiON
Server Enterprise Edition, AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
215 HPQ Proliant: DL380 Storage Server34, Microsoft Windows 2003 PCI, Emulex: LP101−E3, 18, 49, 50, 60 , FC−AL, EMC Y2, 27, See36
DL580 Storage Server34, DL585 Storage [x86] Storage: Server, PCI−X LP1050−E3, 18, 50, 60, 61, 66 , LP1150−E3, FC−SW CLARiiON Y27
Server34 Server Enterprise Edition, 4, 18, 49, 50, 61, 75 , LP982−E3, 18, 50, 60, AX150
Server Enterprise Edition 61, 66
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
216 HPQ Proliant: DL380 Storage Server34, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)3, 18, 49, 50, 60, 61 , FC−AL, EMC Y, Y2
DL580 Storage Server34, DL585 Storage [x86] Storage: Server, PCI−X A7388A (LP1050)3, 18, 49, 50, 60, 61 , FC−SW CLARiiON
Server34 Server Enterprise Edition, AD167A/FC2143 (LP1150)3, 4, 49, 50, 61, AX150
Server Enterprise Edition 112, FCA2214 (QLA2340)18, 19, 20, 21, 22 ,
R2, Server Enterprise FCA2408 (LP982)3, 4, 18, 49, 50, 60, 61
Edition SP1, Server R2,
Server SP1
217 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y2, 27 See23
TX600 [x86] Storage: Server, PCI−X 78, QLA200−E−SP4, 18, 30, 32, 76, 77, 78 , FC−SW CLARiiON
Server Enterprise Edition, QLA210−E−SP4, 30, 31, 32 AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
218 HPQ Proliant: DL380 Storage Server34, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 32, 76, 77, FC−AL, EMC Y27 See23
DL580 Storage Server34, DL585 Storage [x86] Storage: Server, PCI−X 78, QLA210−E−SP4, 30, 31, 32 , FC−SW CLARiiON
Server34 Server Enterprise Edition, QLA2340−E−SP18, 19, 20, 21 , AX150
Server Enterprise Edition QLA2460−E−SP4, 18, 20, 21, 22, 65
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
219 HPQ Proliant: DL380 Storage Server34, Microsoft Windows 2003 PCI, QLogic: QLA2340−E−SP18, 19, 20, 21 , FC−AL, EMC Y2, 27 See23
DL580 Storage Server34, DL585 Storage [x86] Storage: Server, PCI−X QLA2460−E−SP4, 18, 20, 21, 22, 65 FC−SW CLARiiON
Server34 Server Enterprise Edition, AX150
Server Enterprise Edition
R2, Server Enterprise
Edition SP1, Server R2,
Server SP1
220 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X Emulex LP1150−E3, 4, 18, 49, 61, 75 FC−AL, EMC N See36
[x86] Storage: Server, FC−SW CLARiiON
Server Enterprise Edition, AX150
Server Enterprise Edition
SP1, Server SP1
221 Dell PowerVault 745N Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP4, 18, 30, 76, 79 , FC−AL, EMC N See23
[x86] Storage: Server, PCI−X QLA210−E−SP4, 30, 32, 35 FC−SW CLARiiON
Server Enterprise Edition, AX150
Server Enterprise Edition
SP1, Server SP1
222 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, 60, FC−AL, EMC N
[x86]: DataCenter R21, PCI−X 134, 137 FC−SW CLARiiON
Enterprise Edition R21, AX150
Standard Edition R21
223 Unisys Libra Model 520 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86]: DataCenter12, 108, 133 FC−SW CLARiiON
Enterprise Edition12 AX150
224 Unisys: EA1400, FS1400 Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86]: DataCenter12, 123, 132 FC−SW CLARiiON
Enterprise Edition12 AX150
225 Unisys ES7000/one [Xeon] Microsoft Windows 2003 PCI−X Unisys FCH752313−PCX: (LP1050)3, 6, FC−AL, EMC Y
[x86]: Enterprise Edition 60, 121, 123, 141 , (LP1050)3, 6, 60, 121, 141 FC−SW CLARiiON
R21, Standard Edition R21 AX150
226 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 32, 76, 77, 78 FC−AL, EMC N See23
[x86]: Enterprise Edition Express FC−SW CLARiiON
SP1, Standard Edition SP1 AX150
227 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 18, 19, 20, 21 FC−AL, EMC N See23
[x86]: Enterprise Edition Express, FC−SW CLARiiON
SP1, Standard Edition SP1 PCI−X AX150
228 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 32, 76, 77, 78 FC−AL, EMC N See23
[x86]: Enterprise Edition Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, SP1, Standard Edition SP1 PCI−X AX150
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
229 Unisys ES7000/600 Microsoft Windows 2003 PCI, Unisys FCH752313−PCX: (LP1050)3, 60, FC−AL, EMC Y2
[x86]: Enterprise Edition PCI−X 134, 135, (LP1050)3, 60, 134, 136 FC−SW CLARiiON
SP111, Standard Edition AX150
SP111

11/02/2006 261 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
230 Unisys: ES3220, ES3220L Microsoft Windows 2003 PCI, Unisys FCH752313−PCX: (LP1050)3, FC−AL, EMC N
[x86]: Enterprise Edition PCI−X (LP1050)3, 60 FC−SW CLARiiON
SP111, Standard Edition AX150
SP111
231 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 33, 39, 77, 78 FC−AL, EMC N See23
[x86]: Enterprise Edition, Express FC−SW CLARiiON
Standard Edition AX150
232 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 14, 18, 19, 28 FC−AL, EMC N See23
[x86]: Enterprise Edition, Express, FC−SW CLARiiON
Standard Edition PCI−X AX150
233 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 33, 39, 77, 78 FC−AL, EMC N See23
[x86]: Enterprise Edition, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition PCI−X AX150
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
234 HPQ Proliant BL460c: (416653−B21), Microsoft Windows 2003 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), [x86]: Enterprise Edition, HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); Standard Edition (403619−B21)29, 71, 72 AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
235 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI Emulex LP101−E3, 13, 18, 53, 60 FC−AL, EMC Y2, 27 See36
DL36034, DL58034, ML350(G2)34, ML35034, [x86]: Enterprise Edition12, FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, Standard Edition12 AX150
ML530(G3)34, ML53034, ML57034, ML75034;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
236 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI Emulex LP982−E3, 13, 18, 58, 60, 61 FC−AL, EMC Y2, 27 See36
DL36034, DL58034, ML350(G2)34, ML35034, [x86]: Enterprise Edition12, FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, Standard Edition12 AX150
ML530(G3)34, ML53034, ML57034, ML75034;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x342, x350 (6000R), x370
237 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI Emulex: LP101−E3, 18, 53, 60 , LP982−E3, FC−AL, EMC Y2, 27 See36
2500, 255040, 4300, 4350, 4400, 6100, 6300, [x86]: Enterprise Edition12, 18, 58, 60, 61 FC−SW CLARiiON
6350, 6400, 6450, 8450 Standard Edition12 AX150
238 HPQ Proliant: 850034, DL32034, Microsoft Windows 2003 PCI Emulex: LP1050−E3, 13, 18, 53, 60, 61 , FC−AL, EMC Y2, 27 See36
DL360(G2)34, DL36034, DL380(G2)34, [x86]: Enterprise Edition12, LP1150−E3, 4, 13, 18, 53, 61, 75 FC−SW CLARiiON
DL380(G3)34, DL38034, DL58034, Standard Edition12 AX150
ML350(G2)34, ML35034, ML370(G2)34,
ML37034, ML530(G2)34, ML530(G3)34,
ML53034, ML57034, ML75034;
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370
239 Dell PowerEdge: 1550, 2450, 2500, 255040, Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 53, 60, 61 , FC−AL, EMC Y2, 27 See36
4400, 6350, 6400, 645097, 8450 [x86]: Enterprise Edition12, LP1150−E3, 4, 18, 53, 61, 75 FC−SW CLARiiON
Standard Edition12 AX150
240 Fujitsu Siemens Primergy: BX60098, BX620 Microsoft Windows 2003 PCI Fujitsu Siemens BX600−FC22Q4, 18, 19, FC−AL, EMC Y2
S2F104, BX620 S2104, BX620 S3, BX620104, [x86]: Enterprise Edition12, 95, 96 FC−SW CLARiiON
BX630 (2−way), BX630 (4−way), BX630 Standard Edition12 AX150
(8−way), BX660104
241 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI HPQ: A7298A (LP982)3, 13, 18, 53, 60, 61 , FC−AL, EMC Y2
DL36034, DL380(G2)34, DL380(G3)34, [x86]: Enterprise Edition12, A7388A (LP1050)3, 13, 18, 53, 60, 61 , FC−SW CLARiiON
DL38034, DL58034, ML350(G2)34, ML35034, Standard Edition12 AD167A/FC2143 (LP1150)3, 4, 13, 53, 61, AX150
ML370(G2)34, ML37034, ML530(G2)34, 112, FCA2214 (QLA2340)14, 18, 19, 22, 28 ,
ML53034, ML57034, ML75034 FCA2408 (LP982)3, 4, 13, 18, 53, 60, 61
242 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
x330, x335, x340 (4500R), x342, x350 [x86]: Enterprise Edition12, 120 FC−SW CLARiiON
(6000R), x370 Standard Edition12 AX150
243 IBM xSeries: x230, x240, x250, x330, x335, Microsoft Windows 2003 PCI IBM 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−AL, EMC Y2
x340 (4500R), x342, x350 (6000R), x370 [x86]: Enterprise Edition12, 103 FC−SW CLARiiON
Standard Edition12 AX150
244 IBM xSeries: x225, x230, x232, x240, x250, Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)4, 18, 22, 65, 73 , FC−AL, EMC Y2, 27 See23
x330, x335, x340 (4500R), x342, x350 [x86]: Enterprise Edition12, 39M5895 (QLA2462)4, 18, 22, 65, 73 FC−SW CLARiiON
(6000R), x370 Standard Edition12 AX150
245 NEC Express 5800: 120Rd−1, 120Rf−2, Microsoft Windows 2003 PCI NEC N8190−120 (LP1050)3, 13, 18, 53, 55, FC−AL, EMC Y2
140Hd, 140Rc−4, 180Rd−4 [x86]: Enterprise Edition12, 60, 61 FC−SW CLARiiON
Standard Edition12 AX150
246 NEC Express 5800: 320La−R116, 320La116, Microsoft Windows 2003 PCI NEC N8803−031 (QLA2310F)14, 18, 19, FC−AL, EMC Y2
320Lb−R116, 117, 320Lb116, 117 [x86]: Enterprise Edition12, 22, 28 FC−SW CLARiiON
Standard Edition12 AX150
247 HPQ Proliant: DL32034, DL360(G2)34, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 33, 39, 77, FC−AL, EMC Y2, 27 See23
DL36034, DL58034, ML350(G2)34, ML35034, [x86]: Enterprise Edition12, 78, QLA210−E−SP4, 30, 31, 33 , FC−SW CLARiiON
ML370(G2)34, ML37034, ML530(G2)34, Standard Edition12 QLA2340−E−SP14, 18, 19, 28 , AX150
ML530(G3)34, ML53034, ML57034, ML75034; QLA2460−E−SP4, 14, 18, 22, 28, 65
IBM xSeries: x225, x230, x232, x240, x250,
x330, x335, x340 (4500R), x342, x350
(6000R), x370

11/02/2006 262 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
248 Dell PowerEdge: 1550, 2300, 2400, 2450, Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 39, 79 , FC−AL, EMC Y2, 27 See23
2500, 255040, 4300, 4350, 4400, 6100, 6300, [x86]: Enterprise Edition12, QLA210−E−SP4, 30, 33, 35 , FC−SW CLARiiON
6350, 6400, 6450, 8450 Standard Edition12 QLA2340−E−SP10, 14, 18, 19 , AX150
QLA2460−E−SP4, 18, 28, 65, 106
249 Unisys: ES3120, ES3120L, ES3140, Microsoft Windows 2003 PCI Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
ES3140L [x86]: Enterprise Edition12, 100, 139 FC−SW CLARiiON
Standard Edition12 AX150
250 Fujitsu Siemens Primergy: RX200 S2, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 53, 100 FC−AL, EMC Y2, 27, See36
S2, TX600 S2 [x86]: Enterprise Edition12, Express FC−SW CLARiiON Y2, 27, 59
Standard Edition12 AX150
251 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 13, 15, 18, 37 FC−AL, EMC Y2, 27 See36
2850, 6800, 6850; [x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
Digital Henge INNO: HR−4850, HR−6850;
Fujitsu Siemens Primergy RX300 S3;
HPQ Proliant: DL360(G4)34, DL380(G4)34,
DL580(G3)34;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
252 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 13, 15, 18, 37 FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition12 AX150
Fujitsu Siemens Primergy RX300 S3;
HPQ Proliant: DL360(G4)34, DL380(G4)34,
DL580(G3)34;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
253 Fujitsu Siemens Primergy RX300 S3 Microsoft Windows 2003 PCI Emulex LPe1150−E3, 4, 18, 53, 83 FC−AL, EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express FC−SW CLARiiON Y2, 27, 59
Standard Edition12 AX150
254 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express LP1050−E3, 13, 18, 53, 60, 61 , LP1150−E3, FC−SW CLARiiON
Standard Edition12 4, 13, 18, 53, 61, 75 , LP982−E3, 13, 18, 58, AX150
60, 61

255 Dell PowerEdge 1950 Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 53, 60, 61 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express LP982−E3, 18, 58, 60, 61 FC−SW CLARiiON
Standard Edition12 AX150
256 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express 61, LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition12 AX150
HPQ Proliant: DL360(G4)34, DL380(G4)34,
DL580(G3)34;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
257 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express 61, LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−SW CLARiiON
HPQ Proliant: DL360(G4)34, DL380(G4)34, Standard Edition12 AX150
DL580(G3)34;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
258 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 60, 61 , FC−AL, EMC Y2, 27 See36
2850, 6800, 6850 [x86]: Enterprise Edition12, Express LPe1150−E3, 4, 7, 13, 18, 61 FC−SW CLARiiON
Standard Edition12 AX150
259 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI HPQ A7560A (LP1050Ex)3, 4, 13, 18, 53, FC−AL, EMC Y2, Y2,
[x86]: Enterprise Edition12, Express 61 FC−SW CLARiiON 59
Standard Edition12 AX150
260 HPQ Proliant: DL360(G4)34, DL380(G4)34, Microsoft Windows 2003 PCI HPQ A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, Y2,
DL580(G3)34 [x86]: Enterprise Edition12, Express 7, 13, 53, 61 FC−SW CLARiiON 59
Standard Edition12 AX150
261 HPQ Proliant: DL360(G4)34, DL380(G4)34 Microsoft Windows 2003 PCI HPQ AE311A/FC1142SR (QLE2460)4, FC−AL, EMC Y2, Y2,
[x86]: Enterprise Edition12, Express 14, 18, 28, 65, 109 FC−SW CLARiiON 59
Standard Edition12 AX150
262 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)3, 7, 55, 57, 58 FC−AL, EMC Y2, 27 See36
120Ri−2, 140Hf, 140Re−4 [x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
263 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI NEC N8190−127 (LPe1150)3, 7, 55, 57, 58 FC−AL, EMC Y2, 27, 54 See23, 36
[x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
264 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 33, 39, 77, 78 FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
265 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic QLE220−E−SP4, 18, 24, 25, 29 FC−AL, EMC Y2, 27 See23
2850, 6800, 6850; [x86]: Enterprise Edition12, Express FC−SW CLARiiON
Standard Edition12 AX150
Digital Henge INNO: HR−4850, HR−6850;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D

11/02/2006 263 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
266 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic QLE2360−E−SP18, 22, 62, 67, 68 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition12 AX150
NF520;
Samsung: ZSS230, ZSS230D
267 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic QLE2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express 65 FC−SW CLARiiON
IBM xSeries x3455 (7984); Standard Edition12 AX150
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS230, ZSS230D
268 Dell PowerEdge 1950 Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 33, 39, 77, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express 78, QLA200−E−SP18, 30, 39, 79 , FC−SW CLARiiON
Standard Edition12 QLA210−E−SP4, 30, 33, 35 , AX150
QLA2340−E−SP10, 14, 18, 19
269 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP14, 18, 19, 28 , FC−AL, EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express QLA2460−E−SP4, 14, 18, 22, 28, 65 FC−SW CLARiiON Y2, 27, 59
Standard Edition12 AX150
270 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 29 , FC−AL, EMC Y2, 27, 59 See23
[x86]: Enterprise Edition12, Express QLE2360−E−SP18, 22, 62, 67, 68 , FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400; Standard Edition12 QLE2460−E−SP4, 14, 18, 22, 28, 65 AX150
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: ZSS150, ZSS230, ZSS230D
271 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 29 , FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, Express QLE2360−E−SP18, 22, 62, 67, 68 , FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition12 QLE2460−E−SP4, 14, 18, 22, 28, 65 AX150
NF520;
Samsung: ZSS230, ZSS230D
272 IBM xSeries x3455 (7984) Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP14, 18, 22, 62, 68 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express QLE2360−E−SP14, 18, 62, 68, 106 , FC−SW CLARiiON
Standard Edition12 QLE2460−E−SP4, 14, 18, 28, 65, 106 AX150
273 Dell PowerEdge: 1800, 1850, 1950, 2800, Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP10, 14, 18, 62 , FC−AL, EMC Y2, 27 See23
2850, 6800, 6850 [x86]: Enterprise Edition12, Express QLE2460−E−SP4, 10, 14, 18, 65 FC−SW CLARiiON
Standard Edition12 AX150
274 IBM eServer 326m (Model 7969) Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 53, 60, 61 FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
275 IBM: eServer 326m (Model 7969), xSeries Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 53, 60, 61 FC−AL, EMC Y2, 27 See36
x3550 (7978), xSeries x3650 (7979), xSeries [x86]: Enterprise Edition12, Express, FC−SW CLARiiON
x3755 (8877) Standard Edition12 PCI−X AX150
276 Fujitsu Siemens Primergy: RX220, RX600 Microsoft Windows 2003 PCI Emulex LP1050Ex−E3, 4, 18, 53, 100 FC−AL, EMC Y2, 27, See36
S3, TX600 S3 [x86]: Enterprise Edition12, Express, FC−SW CLARiiON Y2, 27, 59
Standard Edition12 PCI−X AX150
277 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LP1150−E3, 4, 13, 18, 53, 61, 75 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Standard Edition12 PCI−X AX150
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
278 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 13, 15, 18, 37 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Standard Edition12 PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy: RX200 S3,
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
279 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex LPe111−E3, 4, 13, 15, 18, 37 FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S3, Standard Edition12 PCI−X AX150
RX220, RX600 S3, TX300 S3, TX600 S3;
IBM eServer 326m (Model 7969);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 264 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
280 Fujitsu Siemens Primergy: RX200 S3, Microsoft Windows 2003 PCI Emulex LPe1150−E3, 4, 18, 53, 83 FC−AL, EMC Y2, 27, See36
RX220, RX600 S3, TX300 S3, TX600 S3 [x86]: Enterprise Edition12, Express, FC−SW CLARiiON Y2, 27, 59
Standard Edition12 PCI−X AX150
281 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
IBM xSeries: x336 (8837)45, x346 (8840)45, Standard Edition12 PCI−X 13, 18, 58, 60, 61 AX150
x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
282 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27, 41 See36
x3755 (8877) [x86]: Enterprise Edition12, Express, LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
Standard Edition12 PCI−X 13, 18, 58, 60, 61 AX150
283 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI Emulex: LP101−E3, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
x3755 (8877) [x86]: Enterprise Edition12, Express, LP1150−E3, 4, 18, 53, 61, 75 , LPe1150−E3, FC−SW CLARiiON
Standard Edition12 PCI−X 4, 7, 18, 53, 61 AX150
284 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050−E3, 18, 53, 60, 61 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, LP982−E3, 18, 58, 60, 61 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition12 PCI−X AX150
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
285 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, 61, LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition12 PCI−X AX150
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
286 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, 61, LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition12 PCI−X AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
287 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI Emulex: LP1050Ex−E3, 4, 13, 18, 60, 61 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, LPe1150−E3, 4, 7, 13, 18, 61 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition12 PCI−X AX150
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
288 HPQ Proliant ML350(G4)34 Microsoft Windows 2003 PCI HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 PCI−X 18, 65 AX150
289 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2, 41
[x86]: Enterprise Edition12, Express, 120 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
290 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 14, 18, 19, 28 FC−AL, EMC Y2
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
291 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 14, 18, 19, 28 FC−AL, EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON Y2, 27, 41
Standard Edition12 PCI−X AX150
292 IBM xSeries: x3550 (7978), x3650 (7979) Microsoft Windows 2003 PCI IBM 24P8053 (QLA2342)4, 14, 18, 19, 28 FC−AL, EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON Y2, 27, 41
Standard Edition12 PCI−X AX150
293 IBM xSeries: x336 (8837)45, x346 (8840)45, Microsoft Windows 2003 PCI IBM: 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
x3550 (7978), x3650 (7979) [x86]: Enterprise Edition12, Express, 120, 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−SW CLARiiON
Standard Edition12 PCI−X 103 AX150
294 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI IBM: 39M5894 (QLA2460)4, 18, 22, 65, 73 , FC−AL, EMC Y2, 27 See23
x3755 (8877) [x86]: Enterprise Edition12, Express, 39M5895 (QLA2462)4, 18, 22, 65, 73 ; FC−SW CLARiiON
Standard Edition12 PCI−X AX150
QLogic: QLA2340−E−SP18, 19, 28,
QLA2460−E−SP4, 18, 22, 28, 65 ,
QLE2460−E−SP4, 18, 22, 28, 65 ,
QLE2460−E−SP4, 18, 28, 65, 106
295 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 33, 39, 77, 78 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition12 PCI−X AX150
AS2500;
IBM xSeries: x336 (8837)45, x346 (8840)45,
x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132

11/02/2006 265 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
296 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLA200−E−SP18, 30, 33, 39, 77, 78 FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition12 PCI−X AX150
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
297 IBM xSeries: x336 (8837)45, x346 (8840)45, Microsoft Windows 2003 PCI QLogic QLA210−E−SP4, 30, 31, 33 FC−AL, EMC Y2, 27 See23
x3550 (7978), x3650 (7979), x3755 (8877) [x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
298 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2340−E−SP14, 18, 19, 28 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
IBM xSeries: x336 (8837)45,x346 (8840)45, Standard Edition12 PCI−X AX150
x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
299 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic QLA2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, 65 FC−SW CLARiiON
IBM xSeries: x3550 (7978), x3650 (7979), Standard Edition12 PCI−X AX150
x3755 (8877);
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
300 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic QLE220−E−SP4, 18, 24, 25, 29 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Digital Henge INNO: HR−4850T, HR−6850T; Standard Edition12 PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
IBM: eServer 326m (Model 7969), xSeries
x3550 (7978), xSeries x3650 (7979), xSeries
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650;
Samsung ZSS132
301 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA200−E−SP18, 30, 39, 79 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, QLA210−E−SP4, 30, 33, 35 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition12 PCI−X AX150
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
302 IBM xSeries: x3550 (7978), x3650 (7979), Microsoft Windows 2003 PCI QLogic: QLA210−E−SP4, 30, 31, 33 , FC−AL, EMC Y2, 27, 41 See23
x3755 (8877) [x86]: Enterprise Edition12, Express, QLA2340−E−SP14, 18, 19, 28 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
303 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP14, 18, 19, 28 , FC−AL, EMC Y2, 27, 59 See23
[x86]: Enterprise Edition12, Express, QLA2460−E−SP4, 14, 18, 22, 28, 65 FC−SW CLARiiON
Intel: SC5300AF2, SE7520BB2, Standard Edition12 PCI−X AX150
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
304 Dell PowerEdge: 1900, 2900, 2950, 6950; Microsoft Windows 2003 PCI QLogic: QLA2340−E−SP10, 14, 18, 19 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, QLE2360−E−SP10, 14, 18, 62 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, Standard Edition12 PCI−X QLE2460−E−SP4, 10, 14, 18, 65 AX150
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL;
Samsung ZSS132
305 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 29 , FC−AL, EMC Y2, 27, 59 See23
[x86]: Enterprise Edition12, Express, QLE2360−E−SP18, 22, 62, 67, 68 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition12 PCI−X QLE2460−E−SP4, 14, 18, 22, 28, 65 AX150
Intel: SC5300AF2, SE7520BB2,
SR1400/SE7520JR2, SR2400/SE7520JR2,
SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650

11/02/2006 266 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
306 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE220−E−SP4, 18, 24, 25, 29 , FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, Express, QLE2360−E−SP18, 22, 62, 67, 68 , FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition12 PCI−X QLE2460−E−SP4, 14, 18, 22, 28, 65 AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
307 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP18, 22, 62, 67, 68 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, QLE2460−E−SP4, 14, 18, 22, 28, 65 FC−SW CLARiiON
IBM eServer 326m (Model 7969); Standard Edition12 PCI−X AX150
Intel: SR4850HW4−M/SR6850HW4−M,
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
308 IBM xSeries: x346 (8840)45, x3550 (7978), Microsoft Windows 2003 PCI QLogic: QLE2360−E−SP18, 22, 62, 68 , FC−AL, EMC Y2, 27 See23
x3650 (7979), x3755 (8877) [x86]: Enterprise Edition12, Express, QLE2360−E−SP18, 62, 68, 106 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
309 Dell PowerEdge 6850 Microsoft Windows 2003 PCI−X Dell 2362M10, 14, 69, 70 FC−AL, EMC Y2
[x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
310 Dell PowerEdge 1855 Microsoft Windows 2003 PCI−X Dell: 2342M10, 14, 18, 19 , LPe1105−M3, 4, FC−AL, EMC Y2
[x86]: Enterprise Edition12, 5, 7, 13,
QME24624, 8, 10, 14 FC−SW CLARiiON
Standard Edition12 AX150
311 Fujitsu Siemens Primergy: RX200, RX300, Microsoft Windows 2003 PCI−X Emulex LP1050−E3, 18, 53, 100 FC−AL, EMC Y2, 27 See36
TX200, TX300 [x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
312 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex LP1150−E3, 4, 18, 53, 61, 75 FC−AL, EMC Y2, 27 See36
2650, 4600, 6600, 6650; [x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
Sun: x4100, x4200
313 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
SH4500; [x86]: Enterprise Edition12, LP1050−E3, 13, 18, 53, 60, 61 , LP1150−E3, FC−SW CLARiiON
Standard Edition12 4, 13, 18, 53, 61, 75 , LP982−E3, 13, 18, 58, AX150
HPQ Proliant: BL40p, DL360(G3)34, 60, 61
DL360(G4)34, DL56034, DL74034, DL760
(G2)34, DL76034, ML570(G2)34;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
314 IBM xSeries x3850/x366 (8863)42 Microsoft Windows 2003 PCI−X Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27, 41 See36
[x86]: Enterprise Edition12, LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
Standard Edition12 13, 18, 58, 60, 61 AX150
315 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X Emulex: LP101−E3, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86]: Enterprise Edition12, LP1050−E3, 18, 53, 60, 61 , LP982−E3, 18, FC−SW CLARiiON
6850 Standard Edition12 58, 60, 61 AX150
316 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X Emulex: LP1050Ex−E3, 4, 13, 18, 53, 60, FC−AL, EMC Y2, 27, See36
[x86]: Enterprise Edition12, 61, LPe111−E3, 4, 13, 15, 18, 37 , FC−SW CLARiiON Y2, 27, 59
Standard Edition12 LPe1150−E3, 4, 7, 13, 18, 53, 61 AX150
317 NEC Express 5800: 140Hf, 140Re−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E3, 4, 13, 15, 18, 37 , FC−AL, EMC Y2
[x86]: Enterprise Edition12, LPe1150−E3, 4, 7, 57, 58 FC−SW CLARiiON
Standard Edition12 AX150
318 NEC Express 5800: 140He, 140Rd−4 Microsoft Windows 2003 PCI−X Emulex: LPe111−E3, 4, 13, 15, 18, 37 , FC−AL, EMC Y2, 27, 54 See23, 36
[x86]: Enterprise Edition12, LPe1150−E3, 4, 7, 57, 58 ; FC−SW CLARiiON
Standard Edition12 AX150
NEC N8190−120 (LP1050)3, 13, 18, 53, 55,
60, 61

319 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ AE311A/FC1142SR (QLE2460)4, FC−AL, EMC Y2, 41
[x86]: Enterprise Edition12, 14, 18, 28, 65, 109 FC−SW CLARiiON
Standard Edition12 AX150
320 HPQ Proliant BL45p Microsoft Windows 2003 PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86]: Enterprise Edition12, for HP Proliant BL25p/BL45p FC−SW CLARiiON
Standard Edition12 381881−B2114, 18, 22, 28, 102 AX150
321 HPQ Proliant: DL360(G3)34, DL360(G4)34, Microsoft Windows 2003 PCI−X HPQ: A7298A (LP982)3, 13, 18, 53, 60, 61 , FC−AL, EMC Y2
DL56034, DL74034, DL760 (G2)34, DL76034, [x86]: Enterprise Edition12, A7388A (LP1050)3, 13, 18, 53, 60, 61 , FC−SW CLARiiON
ML570(G2)34 Standard Edition12 AD167A/FC2143 (LP1150)3, 4, 13, 53, 61, AX150
112, FCA2214 (QLA2340)14, 18, 19, 22, 28 ,
FCA2408 (LP982)3, 4, 13, 18, 53, 60, 61
322 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, Y2,
[x86]: Enterprise Edition12, 7, 13, 53, 61 , AE311A/FC1142SR FC−SW CLARiiON 59
Standard Edition12 (QLE2460)4, 14, 18, 28, 65, 109 AX150
323 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 18, 65; AX150
QLogic: QLE220−E−SP4, 18, 24, 25, 29 ,
QLE2360−E−SP18, 22, 62, 67, 68 ,
QLE2460−E−SP4, 14, 18, 22, 28, 65

11/02/2006 267 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
324 IBM xSeries x3850/x366 (8863)42 Microsoft Windows 2003 PCI−X IBM 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2, 41
[x86]: Enterprise Edition12, 120 FC−SW CLARiiON
Standard Edition12 AX150
325 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
[x86]: Enterprise Edition12, 120, 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−SW CLARiiON
Standard Edition12 103 AX150
326 IBM xSeries: x235, x255, x360, x365, x440 Microsoft Windows 2003 PCI−X IBM: 39M5894 (QLA2460)4, 18, 22, 65, 73 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, 39M5895 (QLA2462)4, 18, 22, 65, 73 FC−SW CLARiiON
Standard Edition12 AX150
327 NEC Express 5800: 110Rg−1, 120Lh, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)3, 13, 18, 53, 55, FC−AL, EMC Y2
120Re−1, 120Rg−2, 180Re−3 [x86]: Enterprise Edition12, 60, 61 FC−SW CLARiiON
Standard Edition12 AX150
328 NEC Express 5800: 120Li, 120Rg−1, Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)3, 13, 18, 53, 55, FC−AL, EMC Y2, 27 See36
120Ri−2, 140Hf, 140Re−4 [x86]: Enterprise Edition12, 60, 61 FC−SW CLARiiON
Standard Edition12 AX150
329 NEC Express 5800: 120Rf−1, 120Rh−2 Microsoft Windows 2003 PCI−X NEC N8190−120 (LP1050)3, 13, 18, 53, 55, FC−AL, EMC Y2, 27
[x86]: Enterprise Edition12, 60, 61 FC−SW CLARiiON
Standard Edition12 AX150
330 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP14, 18, 19, 28 FC−AL, EMC Y2, 27, 59 See23
[x86]: Enterprise Edition12, FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition12 AX150
NF520;
Samsung ZSS150
331 Fujitsu Siemens Primergy RX200 Microsoft Windows 2003 PCI−X QLogic QLA2340−E−SP18, 19, 96 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
332 Digital Henge INNO: HR−4850, HR−6850; Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27, 59 See23
[x86]: Enterprise Edition12, 65 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, Standard Edition12 AX150
NF520;
Samsung ZSS150;
Sun: x4100, x4200
333 Sun: x4100, x4200 Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 22, 28, 65 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
334 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic QLA2460−E−SP4, 18, 28, 65, 106 FC−AL, EMC Y2, 27 See23
2650, 4600, 6600, 6650; [x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
Sun: x4100, x4200
335 Digital Henge INNO SH4500; Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 33, 39, 77, FC−AL, EMC Y2, 27 See23
HPQ Proliant: BL40p, DL360(G3)34, [x86]: Enterprise Edition12, 78, QLA210−E−SP4, 30, 31, 33 FC−SW CLARiiON
DL360(G4)34, DL56034, DL74034, DL760 Standard Edition12 AX150
(G2)34, DL76034, ML570(G2)34;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NF420;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440;
Sun: V20z, V40z, x4100, x4200
336 IBM xSeries x3850/x366 (8863)42 Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 33, 39, 77, FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, 78, QLA210−E−SP4, 30, 31, 33 , FC−SW CLARiiON
Standard Edition12 QLA2340−E−SP14, 18, 19, 28 AX150
337 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Microsoft Windows 2003 PCI−X QLogic: QLA200−E−SP18, 30, 39, 79 , FC−AL, EMC Y2, 27 See23
2650, 2800, 2850, 4600, 6600, 6650, 6800, [x86]: Enterprise Edition12, QLA210−E−SP4, 30, 33, 35 , FC−SW CLARiiON
6850 Standard Edition12 QLA2340−E−SP10, 14, 18, 19 AX150
338 Digital Henge INNO: HR−4850, HR−6850, Microsoft Windows 2003 PCI−X QLogic: QLA2340−E−SP14, 18, 19, 28 , FC−AL, EMC Y2, 27 See23
SH4500; [x86]: Enterprise Edition12, QLA2460−E−SP4, 14, 18, 22, 28, 65 FC−SW CLARiiON
Standard Edition12 AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)34,
DL360(G4)34, DL56034, DL74034, DL760
(G2)34, DL76034, ML570(G2)34;
IBM xSeries: x235, x255, x360, x365, x440;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo: ShenTeng R630, SureServer R630
6003, SureServer R630 6004, SureServer
T630 6003, SureServer T630 6004;
Samsung: SS210, SS3400, SS3440, SS370,
SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
339 HPQ Proliant DL360(G4)34 Microsoft Windows 2003 PCI−X QLogic: QLE220−E−SP4, 18, 24, 25, 29 , FC−AL, EMC Y2, 27, See23
[x86]: Enterprise Edition12, QLE2360−E−SP18, 22, 62, 67, 68 , FC−SW CLARiiON 41, Y2,
Standard Edition12 QLE2460−E−SP4, 14, 18, 22, 28, 65 AX150 27, 59

340 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27, 41 See36
[x86]: Enterprise Edition12, LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
Standard Edition12 13, 18, 58, 60, 61 AX150

11/02/2006 268 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
341 IBM xSeries: x3800/x260 (8865)42, Microsoft Windows 2003 PCI−X105 Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
x3950/x3950E/x460 (8872, 8874)42 [x86]: Enterprise Edition12, LP1050−E3, 13, 18, 53, 60, 61 , LP982−E3, FC−SW CLARiiON
Standard Edition12 13, 18, 58, 60, 61 AX150
342 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 IBM 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2, 41
[x86]: Enterprise Edition12, 120 FC−SW CLARiiON
Standard Edition12 AX150
343 IBM xSeries: x3800/x260 (8865)42, Microsoft Windows 2003 PCI−X105 IBM: 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
x3950/x3950E/x460 (8872, 8874)42 [x86]: Enterprise Edition12, 120, 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−SW CLARiiON
Standard Edition12 103 AX150
344 IBM xSeries x3800/x260 (8865)42 Microsoft Windows 2003 PCI−X105 QLogic QLA2340−E−SP14, 18, 19, 28 FC−AL, EMC Y2, 27, 41 See23
[x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
345 IBM xSeries: x3800/x260 (8865)42, Microsoft Windows 2003 PCI−X105 QLogic QLA2340−E−SP14, 18, 19, 28 FC−AL, EMC Y2, 27 See23
x3950/x3950E/x460 (8872, 8874)42 [x86]: Enterprise Edition12, FC−SW CLARiiON
Standard Edition12 AX150
346 HPQ Proliant BL20p (G2) Microsoft Windows 2003 PCI−X48 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86]: Enterprise Edition12, for HP Proliant BL20p (G2) FC−SW CLARiiON
Standard Edition12 300874−B2114, 18, 22, 28, 47 AX150
347 HPQ Proliant BL25p Microsoft Windows 2003 PCI−X48 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86]: Enterprise Edition12, for HP Proliant BL25p/BL45p FC−SW CLARiiON
Standard Edition12 381881−B2114, 18, 22, 28, 102 AX150
348 HPQ Proliant BL30p Microsoft Windows 2003 PCI−X48 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86]: Enterprise Edition12, for HP Proliant BL30p/BL35p FC−SW CLARiiON
Standard Edition12 354054−B2114, 18, 47 AX150
349 HPQ Proliant BL20p: (G3), (G4) Microsoft Windows 2003 PCI−X48 HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y2
[x86]: Enterprise Edition12, for HP Proliant BL20p (G3) FC−SW CLARiiON
Standard Edition12 361426−B2114, 18, 22, 28, 47 , AX150
Emulex−based BL20p (G3) Fibre
Channel Mezzanine HBA −
394757−B213, 13, 18, 51, 52, 53
350 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X99 Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, LP1050−E3, 13, 18, 53, 60, 61 , LP1150−E3, FC−SW CLARiiON
Standard Edition12 4, 13, 18, 53, 61, 75 , LP982−E3, 13, 18, 58, AX150
60, 61

351 Digital Henge Revo: JS1400, JS2400 Microsoft Windows 2003 PCI−X99 QLogic: QLA2340−E−SP14, 18, 19, 28 , FC−AL, EMC Y2, 27, See23
[x86]: Enterprise Edition12, QLA2460−E−SP4, 14, 18, 22, 28, 65 FC−SW CLARiiON Y2, 27, 59
Standard Edition12 AX150
352 Dell PowerEdge 1955 Microsoft Windows 2003 PCI, PCI Dell: 2342M10, 14, 18, 19 , LPe1105−M3, 4, FC−AL, EMC Y2
[x86]: Enterprise Edition12, Express, 5, 7, 13, QME24624, 8, 10, 14 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
353 HPQ Proliant DL380(G4)34 Microsoft Windows 2003 PCI, PCI Emulex LP1050Ex−E3, 4, 13, 18, 53, 60, 61 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
354 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LP1150−E3, 4, 13, 18, 53, 61, 75 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
355 Fujitsu Siemens Primergy TX200 S3; Microsoft Windows 2003 PCI, PCI Emulex LPe111−E3, 4, 13, 15, 18, 37 FC−AL, EMC Y2, 27 See36
HPQ Proliant DL380(G4)34 [x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
356 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 18, 53, 83 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
357 HPQ Proliant: DL380(G4)34, DL380(G5), Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−AL, EMC Y2, 27 See36
DL580(G4) [x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
358 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI Emulex LPe1150−E3, 4, 7, 13, 18, 53, 61 FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
359 Fujitsu Siemens Primergy TX200 S3 Microsoft Windows 2003 PCI, PCI Emulex: LPe111−E3, 4, 13, 15, 18, 37 , FC−AL, EMC Y2, 27, 59 See36
[x86]: Enterprise Edition12, Express, LPe1150−E3, 4, 18, 53, 83 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
360 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2
[x86]: Enterprise Edition12, Express, 7, 13, 53, 61 , AD167A/FC2143 (LP1150)3, FC−SW CLARiiON
Standard Edition12 PCI−X 4, 13, 53, 61, 112 , AE311A/FC1142SR AX150
(QLE2460)4, 14, 18, 28, 65, 109
361 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: A8002A/FC2142SR (LPe1150)3, 4, FC−AL, EMC Y2, 59
[x86]: Enterprise Edition12, Express, 7, 13, 53, 61 , AE311A/FC1142SR FC−SW CLARiiON
Standard Edition12 PCI−X (QLE2460)4, 14, 18, 28, 65, 109 AX150
362 HPQ Proliant: DL380(G5), DL580(G4) Microsoft Windows 2003 PCI, PCI HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 PCI−X 18, 65; AX150
QLogic QLA2460−E−SP4, 14, 18, 22, 28,
65

363 HPQ Proliant DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic QLE220−E−SP4, 18, 24, 25, 29 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
364 HPQ Proliant: DL380(G4)34, DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic QLE2360−E−SP18, 22, 62, 67, 68 FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, Express, FC−SW CLARiiON
Standard Edition12 PCI−X AX150
365 HPQ Proliant: DL380(G4)34, DL380(G5), Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27 See23
DL580(G3)34, DL580(G4) [x86]: Enterprise Edition12, Express, 65 FC−SW CLARiiON
Standard Edition12 PCI−X AX150
366 HPQ Proliant: DL380(G5), DL580(G3)34, Microsoft Windows 2003 PCI, PCI QLogic QLE2460−E−SP4, 14, 18, 22, 28, FC−AL, EMC Y2, 27, See23
DL580(G4) [x86]: Enterprise Edition12, Express, 65 FC−SW CLARiiON 41, Y2,
Standard Edition12 PCI−X AX150 27, 59

11/02/2006 269 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
367 HPQ Proliant DL580(G3)34 Microsoft Windows 2003 PCI, PCI QLogic: QLE220−E−SP4, 18, 24, 25, 29 , FC−AL, EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express, QLE2360−E−SP18, 22, 62, 67, 68 FC−SW CLARiiON 41, Y2,
Standard Edition12 PCI−X AX150 27, 59

368 Fujitsu Siemens Primergy: RX600, TX600 Microsoft Windows 2003 PCI, Emulex LP1050−E3, 18, 53, 100 FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, PCI−X FC−SW CLARiiON
Standard Edition12 AX150
369 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, Emulex: LP101−E3, 13, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
DL380(G3)34, DL380(G4)34, DL38034, [x86]: Enterprise Edition12, PCI−X LP1050−E3, 13, 18, 53, 60, 61 , LP1150−E3, FC−SW CLARiiON
DL38534, DL580(G2)34, DL580(G3)34, Standard Edition12 4, 13, 18, 53, 61, 75 , LP982−E3, 13, 18, 58, AX150
DL58534, ML350(G3)34, ML370(G3)34, 60, 61
ML370(G4)34;
IBM: eServer 325 (Model 8835), xSeries x345
(8670), xSeries x445 (8870);
Samsung SS140
370 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, Emulex: LP101−E3, 18, 53, 60 , FC−AL, EMC Y2, 27 See36
[x86]: Enterprise Edition12, PCI−X LP1050−E3, 18, 53, 60, 61 , LP982−E3, 18, FC−SW CLARiiON
Standard Edition12 58, 60, 61 AX150
371 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, HPQ: A7298A (LP982)3, 13, 18, 53, 60, 61 , FC−AL, EMC Y2
DL380(G3)34, DL380(G4)34, DL38034, [x86]: Enterprise Edition12, PCI−X A7388A (LP1050)3, 13, 18, 53, 60, 61 , FC−SW CLARiiON
DL38534, DL580(G2)34, DL58534, Standard Edition12 AD167A/FC2143 (LP1150)3, 4, 13, 53, 61, AX150
ML350(G3)34, ML370(G3)34, ML370(G4)34 112, FCA2214 (QLA2340)14, 18, 19, 22, 28 ,
FCA2408 (LP982)3, 4, 13, 18, 53, 60, 61
372 HPQ Proliant: DL380(G4)34, DL38534, Microsoft Windows 2003 PCI, HPQ: AB429A/FC1143 (QLA2460)4, 14, FC−AL, EMC Y2, 27 See23
DL58534, ML370(G4)34 [x86]: Enterprise Edition12, PCI−X 18, 65, AE369A/FC1243 (QLA2462)4, 14, FC−SW CLARiiON
Standard Edition12 18, 65 AX150
373 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM 19K1246 (QLA2310)14, 18, 19, 22, 28, FC−AL, EMC Y2
(8670), xSeries x445 (8870) [x86]: Enterprise Edition12, PCI−X 120 FC−SW CLARiiON
Standard Edition12 AX150
374 IBM xSeries: x345 (8670), x445 (8870) Microsoft Windows 2003 PCI, IBM 24P0960 (QLA2340)14, 18, 19, 22, 28, FC−AL, EMC Y2
[x86]: Enterprise Edition12, PCI−X 103 FC−SW CLARiiON
Standard Edition12 AX150
375 IBM: eServer 325 (Model 8835), xSeries x345 Microsoft Windows 2003 PCI, IBM: 39M5894 (QLA2460)4, 18, 22, 65, 73 , FC−AL, EMC Y2, 27 See23
(8670), xSeries x445 (8870) [x86]: Enterprise Edition12, PCI−X 39M5895 (QLA2462)4, 18, 22, 65, 73 FC−SW CLARiiON
Standard Edition12 AX150
376 Fujitsu Siemens Primergy: RX600, RX800, Microsoft Windows 2003 PCI, QLogic QLA2340−E−SP18, 19, 96 FC−AL, EMC Y2, 27 See23
TX600 [x86]: Enterprise Edition12, PCI−X FC−SW CLARiiON
Standard Edition12 AX150
377 HPQ Proliant: DL14534, DL380(G2)34, Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 33, 39, 77, FC−AL, EMC Y2, 27 See23
DL380(G3)34, DL380(G4)34, DL38034, [x86]: Enterprise Edition12, PCI−X 78, QLA210−E−SP4, 30, 31, 33 , FC−SW CLARiiON
DL38534, DL580(G2)34, DL580(G3)34, Standard Edition12 QLA2340−E−SP14, 18, 19, 28 , AX150
DL58534, ML350(G3)34, ML370(G3)34, QLA2460−E−SP4, 14, 18, 22, 28, 65
ML370(G4)34;
IBM: eServer 325 (Model 8835), xSeries x345
(8670), xSeries x445 (8870);
Samsung SS140
378 Dell PowerEdge: 1800, 1850 Microsoft Windows 2003 PCI, QLogic: QLA200−E−SP18, 30, 39, 79 , FC−AL, EMC Y2, 27 See23
[x86]: Enterprise Edition12, PCI−X QLA210−E−SP4, 30, 33, 35 , FC−SW CLARiiON
Standard Edition12 QLA2340−E−SP10, 14, 18, 19 AX150
379 Unisys ES7000/460 [32−Bit] Microsoft Windows 2003 PCI, Unisys FCH752313−PCX (LP1050)3, FC−AL, EMC Y2
[x86]: Enterprise Edition12, PCI−X 100, 131 FC−SW CLARiiON
Standard Edition12 AX150
380 Bull NovaScale: 2021, 2040, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y2
[x86] Enterprise Edition: port for NovaScale Blade Series CLARiiON
R21, SP1; CFSN202−110018, 20, 21, 22, 107 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP1
381 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y2
[x86] Enterprise Edition: port mini for NovaScale Blade 2021 CLARiiON
R21, SP1; CFSN202−210018, 20, 21, 22, 107 , AX150
SBEFCM (SFF) Mezzanine HBA4, 18, 20,
Microsoft Windows 2003 21, 22, 107 , SBEFCM4 (SFF) 4Gb
[x86] Standard Edition: R21, Mezzanine HBA4, 9, 18, 92, 110
SP1
382 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA4, FC−SW EMC Y2
[x86] Enterprise Edition: 9, 18, 82, 107 , SBEFCM4 (SFF) 4Gb CLARiiON
R21, SP1; Mezzanine HBA4, 9, 18, 92, 110 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP1
383 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86] Enterprise Edition: Express Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27,
R21, SP111; 70 AX150 41, Y2,
27, 59
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
384 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See36
[x86] Enterprise Edition: Express Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27, 59
R21, SP111; 70 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 270 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
385 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 27, See23
[x86] Enterprise Edition: Express AHWFCMOD4, 18, 20, 21, 22, 69, 70 CLARiiON Y2, 27,
R21, SP111; AX150 41, Y2,
27, 59
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
386 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 27, See36
[x86] Enterprise Edition: Express AHWFCMOD4, 18, 20, 21, 22, 69, 70 CLARiiON Y2, 27, 59
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
387 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86] Enterprise Edition: Express, Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27,
Intel: SR4850HW4−M/SR6850HW4−M, R21, SP111; PCI−X 70 AX150 41, Y2,
SR4850HW4/SR6850HW4; 27, 59
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x86] Standard Edition: R21,
G5, T650 SP111
388 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See36
[x86] Enterprise Edition: Express, Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27, 59
Intel: SR4850HW4−M/SR6850HW4−M, R21, SP111; PCI−X 70 AX150
SR4850HW4/SR6850HW4;
Microsoft Windows 2003
Lenovo SureServer: R630 G5, R650, R650 [x86] Standard Edition: R21,
G5, T650 SP111
389 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27 See36
[x86] Enterprise Edition: Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON
R21, SP111; 70 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
390 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86] Enterprise Edition: Module AHWFCMOD4, 18, 20, 21, 22, 69, CLARiiON Y2, 27, 59
R21, SP111; 70 AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
391 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft Windows 2003 PCI−X IBM Emulex 4Gb SFF Fibre Channel FC−SW EMC Y2, 88 See17
[x86] Enterprise Edition: Exp Card (39Y9186)4, 16, 75, 85 CLARiiON
IBM BladeCenter HS21 (Model: 8853)86, 87, R21, SP111; AX150
8853)87;
Microsoft Windows 2003
IBM BladeCenter: LS20 (Model 8850), LS21 [x86] Standard Edition: R21,
(Model 7971)86, LS41 (Model 7972)86 SP111
392 IBM BladeCenter HS20 (Model: 7981), Microsoft Windows 2003 PCI−X IBM Emulex LP1005DC FC Exp Card3, 4, FC−SW EMC Y2 See17
8678)17, 8832)17, 8832−N1X), 8843); [x86] Enterprise Edition: 18, 49, 50, 61, 84 CLARiiON
R21, SP111; AX150
IBM BladeCenter HS40 (Model 8839)
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
393 IBM BladeCenter HS20 (Model: 7981), Microsoft Windows 2003 PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC Y2 See17
8678)17, 8832)17, 8843); [x86] Enterprise Edition: (26R0884)4, 20, 21, 22, 92 CLARiiON
R21, SP111; AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850) Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
394 IBM BladeCenter HS20 (Model: 8678)17, Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)18, 19, FC−SW EMC Y2 See17
8832)17, 8832−N1X); [x86] Enterprise Edition: 20, 21, 22, 90, 91 CLARiiON
R21, SP111; AX150
IBM BladeCenter HS40 (Model 8839)
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
395 IBM BladeCenter HS20 (Model 7981) Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)18, 19, FC−SW EMC Y2 See17
[x86] Enterprise Edition: 20, 22, 90, 91, 101 CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
396 IBM BladeCenter HS20 (Model: 7981), 8843) Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)19, 20, FC−SW EMC Y2 See17
[x86] Enterprise Edition: 22, 101 CLARiiON
R21, SP111; AX150
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
397 IBM BladeCenter HS20 (Model: 7981), Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (48P7061)4, 18, FC−SW EMC Y2 See17
8678)17, 8832)17, 8843); [x86] Enterprise Edition: 19, 20, 21, 22 CLARiiON
R21, SP111; AX150
IBM BladeCenter HS40 (Model 8839)
Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111
398 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft Windows 2003 PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y2 See17
[x86] Enterprise Edition: (26R0890)4, 20, 21, 22, 92 , FC Exp Card CLARiiON
IBM BladeCenter: HS21 (Model 8853)86, 87 , 1 11
R2 , SP1 ; (26K4841)18, 19, 20, 21, 22, 89, 90, 91 AX150
LS20 (Model 8850), LS21 (Model 7971)86,
LS41 (Model 7972)86 Microsoft Windows 2003
[x86] Standard Edition: R21,
SP111

11/02/2006 271 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot Comments
399 Bull NovaScale: 2021, 2040, 2320 Microsoft Windows 2003 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y2
[x86]: Enterprise Edition, port for NovaScale Blade Series CLARiiON
Standard Edition CFSN202−110014, 18, 22, 28, 107 AX150
400 Bull NovaScale: 2021, 2320 Microsoft Windows 2003 PCI−X Bull: 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y2
[x86]: Enterprise Edition, port mini for NovaScale Blade 2021 CLARiiON
Standard Edition CFSN202−210014, 18, 22, 28, 107 , AX150
SBEFCM (SFF) Mezzanine HBA4, 14, 18,
22, 28, 107 , SBEFCM4 (SFF) 4Gb
Mezzanine HBA4, 14, 18, 92, 110
401 Intel SBXD62 Blade Server Microsoft Windows 2003 PCI−X Intel: SBEFCM (SFF) Mezzanine HBA4, FC−SW EMC Y2
[x86]: Enterprise Edition, 14, 18, 28, 107 , SBEFCM4 (SFF) 4Gb CLARiiON
Standard Edition Mezzanine HBA4, 14, 18, 92, 110 AX150
402 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27,
Standard Edition12 70 AX150 41, Y2,
27, 59

403 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27, 59
Standard Edition12 70 AX150
404 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express AHWFCMOD4, 14, 18, 22, 28, 69, 70 CLARiiON Y2, 27,
Standard Edition12 AX150 41, Y2,
27, 59

405 Samsung: ZSS230, ZSS230D Microsoft Windows 2003 PCI Samsung Intel (r) Fibre Channel Module FC−SW EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express AHWFCMOD4, 14, 18, 22, 28, 69, 70 CLARiiON Y2, 27, 59
Standard Edition12 AX150
406 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86]: Enterprise Edition12, Express, Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27,
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition12 PCI−X 70 AX150 41, Y2,
SR4850HW4/SR6850HW4; 27, 59

Lenovo SureServer: R630 G5, R650, R650


G5, T650
407 Digital Henge INNO: HR−4850T, HR−6850T; Microsoft Windows 2003 PCI Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See36
[x86]: Enterprise Edition12, Express, Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27, 59
Intel: SR4850HW4−M/SR6850HW4−M, Standard Edition12 PCI−X 70 AX150
SR4850HW4/SR6850HW4;
Lenovo SureServer: R630 G5, R650, R650
G5, T650
408 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27 See36
[x86]: Enterprise Edition12, Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON
Standard Edition12 70 AX150
409 Digital Henge INNO: HR−4850, HR−6850 Microsoft Windows 2003 PCI−X Digital Henge Intel (r) Fibre Channel FC−SW EMC Y2, 27, See23
[x86]: Enterprise Edition12, Module AHWFCMOD4, 14, 18, 22, 28, 69, CLARiiON Y2, 27, 59
Standard Edition12 70 AX150
410 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft Windows 2003 PCI−X IBM Emulex 4Gb SFF Fibre Channel FC−SW EMC Y2, 88 See17
[x86]: Enterprise Edition12, Exp Card (39Y9186)4, 57, 75, 85 CLARiiON
IBM BladeCenter HS21 (Model: 8853)86, 87, Standard Edition12 AX150
87
8853) ;
IBM BladeCenter: LS20 (Model 8850), LS21
(Model 7971)86, LS41 (Model 7972)86
411 IBM BladeCenter HS20 (Model: 7981), Microsoft Windows 2003 PCI−X IBM Emulex LP1005DC FC Exp Card3, 4, FC−SW EMC Y2 See17
8678)17, 8832)17, 8832−N1X), 8843); [x86]: Enterprise Edition12, 13, 18, 53, 61, 84 CLARiiON
Standard Edition12 AX150
IBM BladeCenter HS40 (Model 8839)
412 IBM BladeCenter HS20 (Model: 7981), Microsoft Windows 2003 PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC Y2 See17
8678)17, 8832)17, 8843); [x86]: Enterprise Edition12, (26R0884)4, 14, 22, 28, 92 CLARiiON
Standard Edition12 AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
413 IBM BladeCenter HS20 (Model: 8678)17, Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)14, 18, FC−SW EMC Y2 See17
8832)17, 8832−N1X); [x86]: Enterprise Edition12, 19, 22, 28, 90, 91 CLARiiON
Standard Edition12 AX150
IBM BladeCenter HS40 (Model 8839)
414 IBM BladeCenter HS20 (Model 7981) Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)14, 18, FC−SW EMC Y2 See17
[x86]: Enterprise Edition12, 19, 22, 90, 91, 114 CLARiiON
Standard Edition12 AX150
415 IBM BladeCenter HS20 (Model: 7981), 8843) Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (13N2203)14, 19, FC−SW EMC Y2 See17
[x86]: Enterprise Edition12, 22, 114 CLARiiON
Standard Edition12 AX150
416 IBM BladeCenter HS20 (Model: 7981), Microsoft Windows 2003 PCI−X IBM HS20 FC Exp Card (48P7061)4, 14, FC−SW EMC Y2 See17
8678)17, 8832)17, 8843); [x86]: Enterprise Edition12, 18, 19, 22, 28 CLARiiON
Standard Edition12 AX150
IBM BladeCenter HS40 (Model 8839)
417 IBM BladeCenter HS20 (Model: 7981), 8843); Microsoft Windows 2003 PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y2 See17
[x86]: Enterprise Edition12, (26R0890)4, 14, 22, 28, 92 , FC Exp Card CLARiiON
IBM BladeCenter: HS21 (Model 8853)86, 87, Standard Edition12 (26K4841)14, 18, 19, 22, 28, 89, 90, 91 AX150
LS20 (Model 8850), LS21 (Model 7971)86,
LS41 (Model 7972)86
1. VDS (Virtual Disk Service) is currently supported for Windows 2003 R2 operating systems. EMC Solutions Enabler 6.2 (minimum version) is required to support VDS for Windows 2003
R2.
2. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
3. BIOS 1.70a3
4. SNIA HBA API Supported.
5. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003.
6. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
7. Firmware Version 2.50a6
8. BIOS 1.11
9. Driver Version 9.1.2.16 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
10. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or

11/02/2006 272 CLARiiON AX150


CLARiiON AX150

HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
11. Supports LUNs greater than 2TB in size. Minimum Service Pack 1 (SP1) required.
12. Maximum supported LUN size is 2TB for Windows 2003 without Service Pack 1 (SP1.)
13. Driver Version 1.20a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
14. Driver Version 9.1.2.16 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
15. Firmware Version 2.50a8
16. Driver Version 1.20a3
17. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
18. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
19. BIOS 1.47
20. Driver Version 9.1.2.16 STORPort Miniport Driver
21. Driver Version 9.1.2.15 STORPort Miniport Driver
22. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
23. EMC provides in−depth documentation for configurations with QLogic HBAs that contains helpful information for installing and configuring QLogic HBAs with EMC Storage. This
documentation is located in the EMC section of the QLogic website (http://www.qlogic.com) along with HBA drivers, and BIOS.
24. BIOS 1.02
25. Driver Version 9.1.2.14 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
26. Driver Version 9.1.2.19 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
27. EMC provides documentation for boot configurations that contains helpful information for systems booting from EMC storage. Visit EMC Powerlink and download part number
300−000−603 for the Windows Host Connectivity Guide.
28. Driver Version 9.1.2.15 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
29. Driver Version 9.1.2.19 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
30. BIOS 1.23
31. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. SCSI Miniport (SCSIPort) Driver
32. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
33. Driver Version 9.1.2.16 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
34. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
35. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. This driver requires Microsoft SCSIPort hotfix Q883114. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];883114 SCSI Miniport (SCSIPort) Driver
36. EMC provides in−depth documentation for configurations with Emulex HBAs that contains helpful information for installing and configuring Emulex HBAs with EMC Storage. Visit the
EMC driver page on the Emulex website (http://www.emulex.com/ts/docoem/emc/index.html) and download part number 300−001−157 for guide "EMC Fibre Channel with Emulex Host
Bus Adapters in the Windows Environment."
37. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI FC Port driver As of 2.40a2 Microsoft will no longer allow the
Emulex Port Driver to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO
solution and block submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
38. Supports Stratus OS 3.1.x.
39. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
40. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
41. When booting from an external storage array, press F1 during server POST and set BIOS Start Options to point to the bus slot containing the SAN boot adapter (Default is Planar
SCSI.)
42. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
43. Requires Stratus OS 3.1
44. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
45. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
46. Supports Stratus OS 4.1 FTSSS Release
47. BIOS 1.45
48. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
49. Driver Version 1.11a3 STORPort Miniport Driver
50. Driver Version 1.20a3 STORPort Miniport Driver
51. Firmware Version 1.91a2
52. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. STORPort Miniport Driver
53. Driver Version 1.11a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
54. EMC does not support booting from external arrays if the boot LUN uses a FAT32 file system and Powerpath is installed. For Powerpath/Boot support, NTFS must be used.
55. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
56. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
57. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
58. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
59. Legacy (x86) boot mode supported only for this server. EFI boot is not supported. EFI boot code should be removed from the HBA if installed.
60. Firmware Version 1.91a5
61. Driver Version 2.40a3 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. As of 2.40a2 Microsoft will no longer allow the Emulex Port Driver
to be used in any HCT LOGO solution or block submissions. The Port driver is still digitally signed, but STORPort drivers will be required for all new HCT LOGO solution and block
submissions. SCSI FC Port driver. EMC recommends using STORPort drivers where available.
62. BIOS 1.05
63. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
64. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
65. BIOS 1.08
66. Driver Version 1.11a3
67. Driver Version 9.1.2.16 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
68. Driver Version 9.1.2.15 EMC recommends upgrading to the most recent, EMC−Approved, HBA driver. Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
69. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
70. BIOS 1.06
71. Driver Version 9.1.2.14
72. BIOS 1.16
73. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com STORPort Miniport Driver Requires
Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
74. Driver Version 9.1.2.16 If using EFI boot driver for external boot, use QLogic EFI Boot code version 1.40. Available at http://www.qlogic.com Requires Microsoft STORPort hotfix
Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently requires Service Pack 1 (SP1) to be installed before the hotfix
can be installed. STORPort Miniport Driver
75. Firmware Version 2.10a10
76. Driver Version 9.1.2.15 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
77. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have

11/02/2006 273 CLARiiON AX150


CLARiiON AX150

Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
78. Driver Version 9.1.2.11 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available.
79. Driver Version 9.1.2.10 Minimum supported driver due to compatibility reasons. END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for
Windows 2003 operating systems. EMC recommends migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have
Windows 2003 SCSI drivers installed, but any fixes or HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers
and information on migrating from SCSI to STOR under Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI
Miniport (SCSIPort) Driver. EMC recommends using STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
80. QLogic SANSurfer/SANBlade Manager is not supported. Use QLogic SANCLI utility.
81. 3.2Ghz and 3.6Ghz versions of this server are supported.
82. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
83. Firmware Version 2.50a4
84. Firmware Version 1.90a5
85. BIOS 1.71a0
86. Mixing 2Gb and 4Gb fibre channel expansion cards is not supported in this server.
87. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
88. Internal port(s) on QLogic or McData 4Gb FC switch module(s) must be set to 4Gb to SAN boot.
89. Refer to EMC Knowledgebase ID emc105679 for any special HBA drivers that may be required.
90. Due to the HS20's embedded FC−SW design, array lun masking is required to assign LUNS to each individual blade server.
91. Dual−port FC switch module. Can be used in place of Optical PassThru Module (OPM.)
92. BIOS 1.12
93. Please read Stratus CAC Alert 2300 prior to the installation of QLA2460−E−SP HBAs.
94. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver
95. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
96. Driver Version 9.0.2.17 Minimum supported driver due to compatibility reasons. STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see
http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
97. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
98. BX600 uses an embedded fibre channel controller. Contact Fujitsu Siemens to acquire proper BIOS for embedded fibre channel controller.
99. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
100. Firmware Version 1.91a1
101. Driver Version 9.1.2.15
102. BIOS 1.48
103. This HBA is equivalent to the QLogic QLA2340.
104. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
105. Accepts PCI−X 1.0 and 2.0 HBAs.
106. Driver Version 9.1.2.10 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. This driver requires Microsoft SCSIPort hotfix Q883114. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];883114
107. BIOS 1.43
108. Firmware Version 1.90a4
109. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available. SCSI Miniport (SCSIPort) Driver
110. Driver Version 9.1.2.11
111. Driver Version 9.1.2.10 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
112. Firmware Version 2.10a9
113. Driver Version 1.11a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed.
114. Driver Version 9.1.2.15 Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980
115. QLogic SanBlade Manager is not supported.
116. Bus Enumeration Issue Causes Problems using SYMCLI SCSI bus enumeration of disks will change depending on cold boot or warm boot. This causes symcli commands to fail
because the path is changed and SYMCLI can no longer communicate with the Symmetrix.
By "shutdown" and booting system, internal disks are assigned first, followed by Symmetrix disks.
By "restart" the system, Symmetrix disks are assigned first, followed by internal disks. Drive letter are not changed in both cases.
The workaround is to perform "symcfg discover" after rebooting.
117. Supports Stratus OS 2.0.X through 2.1.X.
118. Systems running Stratus OS 1.2.2.X or 1.3 require MS hotfix Q327477 and VxVM 2.7 Hotfix 5A. Stratus OS 1.3.1 and above incorporates these hotfixes.
119. Supports Stratus OS 1.3.X through 2.1.X.
120. This HBA is equivalent to the QLogic QLA2310.
121. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
122. Driver Version 1.10x1
123. RPQ or Unisys Custom Engineering Request (CER) required.
124. Driver Version 1.10a4 STORPort Miniport Driver
125. Driver Version 1.02a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
126. Driver Version 1.10a4 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
127. Driver Version 1.11a1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
128. Driver Version 1.02a3 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
129. Driver Version 1.11a1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
130. Driver Version 1.11u1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
131. Driver Version 1.11u1 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
132. Driver Version 1.11a1 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
133. Driver Version 1.02a3 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
134. Driver Version 1.20a3 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
135. Driver Version 1.10x1 Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
136. Driver Version 1.10x1 STORPort Miniport Driver Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
137. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. Driver can be acquired from Unisys at http://www.support.unisys.com/support.htm
138. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm
139. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980

11/02/2006 274 CLARiiON AX150


CLARiiON AX150

140. Driver Version 1.10a4 STORPort Miniport Driver Requires Microsoft STORPort hotfix Q908980. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];908980 Driver can
be acquired from Unisys at http://www.support.unisys.com/support.htm
141. Driver Version 1.10x1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver
142. Driver Version 1.11u1 Requires Microsoft STORPort hotfix Q916048. Please see http://support.microsoft.com/default.aspx?scid=kb;[LN];916048. NOTE: Hotfix Q916048 currently
requires Service Pack 1 (SP1) to be installed before the hotfix can be installed. STORPort Miniport Driver Driver can be acquired from Unisys at
http://www.support.unisys.com/support.htm

MiracleLinux MLSE [32−Bit]

MiracleLinux MLSE [32−Bit]


Host Bus Storage External
No. Host System Operating System Host Bus Adapter Topology Array Boot
1 HPQ Proliant: DL3209, DL360(G2)9, DL3609, DL380(G2)9, DL380(G3)9, DL3809, MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
DL580(G2)9, DL5809, ML350(G2)9, ML350(G3)9, ML3509, ML370(G2)9, ML3709, [32−Bit] 4.0 SP1 QLE220−E−SP3, FC−SW CLARiiON
ML530(G2)9, ML530(G3)9, ML5309, ML5709, ML7509 v2.6.9−34.21AX1, 2 7, 8, 10 AX150
2 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; MiracleLinux MLSE PCI Emulex FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express LPe111−E3, 4, FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.21AX1, 2 5, 6 AX150
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9, DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
3 Dell PowerEdge 1950 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 7, 8 AX150
4 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 7, 8, 10 AX150
5 Dell PowerEdge: 2900, 2950, 6950; MiracleLinux MLSE PCI Emulex FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, LPe111−E3, 4, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX1, 2 PCI−X 5, 6 AX150
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, 6950; MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX1, 2 PCI−X 7, 8 AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
7 HPQ Proliant ML350(G4)9 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 PCI−X 7, 8, 10 AX150
8 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 PCI−X11 7, 8, 10 AX150
9 Digital Henge SH4500R4; MiracleLinux MLSE PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; [32−Bit] 4.0 SP1 QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 7, 8, 10 AX150
HPQ Proliant: BL40p, DL360(G3)9, DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
10 Dell PowerEdge: 1800, 2800 MiracleLinux MLSE PCI, PCI QLogic FC−AL, EMC Y
[32−Bit] 4.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 PCI−X 7, 8 AX150
11 HPQ Proliant: DL1459, DL380(G2)9, DL380(G3)9, DL380(G4)9, DL3809, DL3859, MiracleLinux MLSE PCI, QLogic FC−AL, EMC Y
DL580(G2)9, DL580(G3)9, DL5859, ML370(G3)9, ML370(G4)9; [32−Bit] 4.0 SP1 PCI−X QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX1, 2 7, 8, 10 AX150
Samsung SS140
1.Native multipathing is not supported on boot−from−SAN configurations.
2.Based on Asianux 2.0.
3.SNIA HBA API Supported.
4.Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5.Driver Version 8.0.16.18 Driver is integrated into the kernel.
6.BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7.BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
8.Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
9.HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Driver/BIOS are available at http://www.qlogic.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

MiracleLinux MLSE [AMD64]

MiracleLinux MLSE [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge 6950; MiracleLinux MLSE [AMD64] 4.0 SP1 PCI Express, Emulex LPe111−E5, 11, 12, 13 FC−AL, EMC CLARiiON Y
IBM eServer 326m (Model v2.6.9−34.21AX1, 2 PCI−X FC−SW AX150
7969)

11/02/2006 275 CLARiiON AX150


CLARiiON AX150

MiracleLinux MLSE [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
2 Dell PowerEdge 6950 MiracleLinux MLSE [AMD64] 4.0 SP1 PCI Express, QLogic QLE220−E−SP5, 6, 7 FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX1, 2 PCI−X FC−SW AX150
3 Sun: x4100, x4200 MiracleLinux MLSE [AMD64] 4.0 SP1 PCI−X Emulex: LP1050−E5, 10, 11, 12 , FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX1, 2 LP982−E5, 11, 12; FC−SW AX150
QLogic QLA2340−E−SP3, 4, 5
4 HPQ Proliant: DL1459, MiracleLinux MLSE [AMD64] 4.0 SP1 PCI, PCI−X QLogic QLE220−E−SP5, 6, 7, 8 FC−AL, EMC CLARiiON Y
DL3859, DL5859 v2.6.9−34.21AX1, 2 FC−SW AX150
1. Native multipathing is not supported on boot−from−SAN configurations.
2. Based on Asianux 2.0.
3. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
5. SNIA HBA API Supported.
6. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
7. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
8. Driver/BIOS are available at http://www.qlogic.com
9. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Firmware Version 1.91a5
11. Driver Version 8.0.16.18 Driver is integrated into the kernel.
12. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
13. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

MiracleLinux MLSE [EM64T]

MiracleLinux MLSE [EM64T]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, MiracleLinux MLSE [EM64T] 4.0 PCI Express Emulex LPe111−E4, FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX2, 3 5, 6, 7 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)1, DL380(G4)1,
DL580(G3)1, ML350(G4)1, ML370(G4)1;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
2 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE [EM64T] 4.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP6, 8, 9, FC−SW CLARiiON
10 AX150
3 Dell PowerEdge 1950 MiracleLinux MLSE [EM64T] 4.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP6, 9, FC−SW CLARiiON
10 AX150
4 Dell PowerEdge: 2900, 2950; MiracleLinux MLSE [EM64T] 4.0 PCI Express, Emulex LPe111−E4, FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X 5, 6, 7 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
5 HPQ Proliant ML350(G4)1 MiracleLinux MLSE [EM64T] 4.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X QLE220−E−SP6, 8, 9, FC−SW CLARiiON
10 AX150
6 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, MiracleLinux MLSE [EM64T] 4.0 PCI Express, QLogic FC−AL, EMC Y
6800, 6850; SP1 v2.6.9−34.21AX2, 3 PCI−X QLE220−E−SP6, 9, FC−SW CLARiiON
10 AX150
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
7 Digital Henge Revo: JS1400, JS2400 MiracleLinux MLSE [EM64T] 4.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X11 QLE220−E−SP6, 8, 9, FC−SW CLARiiON
10 AX150
8 Digital Henge SH4500R4; MiracleLinux MLSE [EM64T] 4.0 PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP6, 8, 9, FC−SW CLARiiON
TX300 S2; 10 AX150
HPQ Proliant DL360(G4)1;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003
9 HPQ Proliant DL580(G3)1 MiracleLinux MLSE [EM64T] 4.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 Express, PCI−X QLE220−E−SP6, 8, 9, FC−SW CLARiiON
10 AX150
10 Dell PowerEdge: 1800, 2800 MiracleLinux MLSE [EM64T] 4.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 Express, PCI−X QLE220−E−SP6, 9, FC−SW CLARiiON
10 AX150
11 HPQ Proliant: DL380(G4)1, ML370(G4)1 MiracleLinux MLSE [EM64T] 4.0 PCI, PCI−X QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP6, 8, 9, FC−SW CLARiiON
10 AX150
1. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
2. Native multipathing is not supported on boot−from−SAN configurations.
3. Based on Asianux 2.0.
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Driver Version 8.0.16.18 Driver is integrated into the kernel.
6. SNIA HBA API Supported.
7. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. Driver/BIOS are available at http://www.qlogic.com
9. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
10. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com

11/02/2006 276 CLARiiON AX150


CLARiiON AX150

11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Novell Netware

Novell Netware
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5 SP314, 15 Express QLE2360−E−SP18, 19, 24, FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL380(G4)16, DL580(G3)16, ML370(G4)16; 25 AX1501, 2,
3, 4, 5, 6, 7,
IBM xSeries x336 (8837)21 8, 9, 10, 11,
12, 13

2 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5 SP314, 15 Express QLE2460−E−SP18, 19, 22 FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL580(G3)16, ML370(G4)16 AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13

3 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5 SP314, 15 QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX200 S2, RX300, RX300 S2, AX1501, 2,
TX150, TX200, TX200 S2, TX300, TX300 S2; 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016,
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
4 Fujitsu Siemens Primergy RX300 S2 Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5 SP414 QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13

5 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5 SP414, 15 QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX300, TX150, TX200, TX300; AX1501, 2,
3, 4, 5, 6, 7,
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016, 8, 9, 10, 11,
12, 13
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
6 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255023, 4300, 4350, 4400, Novell Netware PCI QLogic: QLA200−E−SP17, FC−AL, EMC Y
6100, 6300, 6350, 6400, 6450, 8450; 6.5: SP314, 15, 18, 19, QLA2340−E−SP18, FC−SW CLARiiON
SP414, 15, 19, 20 AX1501, 2,
HPQ Netserver LC: 2000 U3, 2000r; SP4a14, SP514 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
HPQ Netserver LH: (LH Pro), 3, 300028, 4, 6000/LH 6000r, II, PRO, lll;
HPQ Netserver: LP 2000r, LT 6000R, LX PRO, LXR 8000, LXR 8500, LXR
PRO, LXR PRO8;
HPQ Proliant: 160016, 185016, 250016, 300016, 500016, 550016, 600016, 6400R,
650016, 700016, 800016, 850, 850016, DL32016, DL360(G2)16, DL36016,
DL58016, ML350(G2)16, ML35016, ML370(G2)16, ML37016, ML530(G2)16,
ML530(G3)16, ML53016, ML57016, ML75016;
IBM Netfinity: 4500R, 5000, 5500, 5500 M10, 5500 M20, 5600, 6000R, 7000,
7000 M1027, 7100, 7600, 8500, 8500R;
IBM xSeries: x225, x230, x232, x240, x250, x330, x335, x340 (4500R), x350
(6000R)
7 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic QLA200−E−SP17, FC−AL, EMC Y
6.5: SP314, 15, 18, 19 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX300, TX150, TX200, TX300; SP414, 15, AX1501, 2,
SP4a14, SP514 3, 4, 5, 6, 7,
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016, 8, 9, 10, 11,
12, 13
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
8 Dell PowerEdge: 1800, 1850, 2800, 2850; Novell Netware PCI, QLogic: QLA200−E−SP17, FC−AL, EMC Y
6.5: SP314, 15, PCI−X 18, 19, QLA2340−E−SP18, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX600, TX600; SP414, 15, 19, 20 AX1501, 2,
SP4a14, SP514 3, 4, 5, 6, 7,
HPQ Proliant: DL360(G4)16, DL380(G2)16, DL380(G3)16, DL380(G4)16, 8, 9, 10, 11,
12, 13
DL38016, DL580(G2)16, DL580(G3)16, ML350(G3)16, ML370(G3)16,
ML370(G4)16;
IBM xSeries: x342, x345 (8670), x360, x365, x370, x440, x445 (8870);
Samsung SS140
9 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5: SP414, 15, Express QLE2360−E−SP18, 19, 24, FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL380(G4)16, DL580(G3)16, ML370(G4)16; SP4a14, SP514 25 AX1501, 2,
3, 4, 5, 6, 7,
IBM xSeries x336 (8837)21 8, 9, 10, 11,
12, 13

11/02/2006 277 CLARiiON AX150


CLARiiON AX150

Novell Netware
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
10 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic: QLA200−E−SP17, FC−AL, EMC Y
6.5: SP414, 15, Express, 18, 19, QLA2340−E−SP18, FC−SW CLARiiON
SP4a14, SP514 PCI−X 19, 20, QLE2360−E−SP18, AX1501, 2,
19, 24, 25 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13

11 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850; Novell Netware PCI QLogic FC−AL, EMC Y
6.5: SP414, Express QLE2460−E−SP18, 19, 22 FC−SW CLARiiON
HPQ Proliant: DL360(G4)16, DL580(G3)16, ML370(G4)16 SP4a14, SP514 AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13

12 Dell PowerEdge: 2900, 2950 Novell Netware PCI QLogic FC−AL, EMC Y
6.5: SP414, Express, QLE2460−E−SP18, 19, 22 FC−SW CLARiiON
SP4a14, SP514 PCI−X AX1501, 2,
3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13

13 Dell PowerEdge: 1600SC, 1750, 2600, 2650, 4600, 6600, 6650; Novell Netware PCI−X QLogic FC−AL, EMC Y
6.5: SP4a14, QLA2340−E−SP18, 19, 20 FC−SW CLARiiON
Fujitsu Siemens Primergy: F25029, RX200, RX300, RX300 S2, TX150, TX200, SP514 AX1501, 2,
TX300; 3, 4, 5, 6, 7,
8, 9, 10, 11,
12, 13
HPQ Proliant: DL360(G3)16, DL56016, DL74016, DL760 (G2)16, DL76016,
ML570(G2)16;
IBM xSeries: x235, x255, x336 (8837)21, x346 (8840)21, x3850/x366 (8863)26;
LangChao: NC2000, NF420;
Samsung: SS210, SS370, SS3840
1. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
2. No MirrorView or SnapView used on boot LUNs.
3. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
4. Novell Storage Services supported.
5. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
6. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After Abend".
When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
7. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
8. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any found in
previous boot documentation.
9. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
10. Remote boot not supported with PERC controllers enabled in system BIOS.
11. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
12. Edit config.sys with the following: Files=100, Buffers=99
13. Supports eight (8) hosts per array.
14. Novell OES is supported on this kernel.
15. PowerPath is not supported in conjunction with host−based mirroring.
16. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
17. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. SNIA HBA API Supported.
19. Driver Version 6.90m
20. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
22. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
24. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
25. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
27. This server only supports 5 Volt HBAs: QLogic 22XX family (if applicable), QLogic 23XX family, Emulex LP8000, and Emulex LP850 (if applicable).
28. HP Netserver LH3000 U3 is supported in the same configurations as the standard LH 3000.
29. Must use standard PCI 32bit/33MHz slot for SCSI

Oracle Enterprise Linux [32−Bit]

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255026, Oracle Enterprise PCI Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450; Linux [32−Bit] 4 U4 QLogic: QLA200−E−SP2, 7, 8, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLA210−E−SP2, 7, 8 AX150
HPQ Proliant: DL32018, DL360(G2)18, DL36018,
DL380(G2)18, DL380(G3)18, DL38018, DL580(G2)18,
DL58018, ML350(G2)18, ML350(G3)18, ML35018,
ML370(G2)18, ML37018, ML530(G2)18, ML530(G3)18,
ML53018, ML57018, ML75018
2 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, 255026, Oracle Enterprise PCI Emulex: LP1050−E2, 5, 6, 14, LP982−E2, 5, 6; FC−AL, EMC Y
4300, 4350, 4400, 6100, 6300, 6350, 6400, 6450, 8450 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP2, 7, 12 AX150
3 HPQ Proliant: DL32018, DL360(G2)18, DL36018, DL58018, Oracle Enterprise PCI Emulex: LP1050−E5, 6, 14, LP982−E5, 6 FC−AL, EMC Y
ML350(G2)18, ML350(G3)18, ML35018, ML370(G2)18, Linux [32−Bit] 4 U4 FC−SW CLARiiON
ML37018, ML530(G2)18, ML530(G3)18, ML53018, ML57018, v2.6.9−42.0.0.0.1.EL AX150
ML75018
4 NEC Express 5800: 120Rd−1, 120Rf−2, 140Hd, 140Rc−4, Oracle Enterprise PCI NEC N8190−120 (LP1050)5, 6, 9, 20 FC−AL, EMC Y
180Rd−4 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150

11/02/2006 278 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
5 HPQ Proliant: DL32018, DL360(G2)18, DL36018, Oracle Enterprise PCI QLogic: QLA2340−E−SP7, 12, FC−AL, EMC Y
DL380(G2)18, DL380(G3)18, DL38018, DL580(G2)18, Linux [32−Bit] 4 U4 QLE220−E−SP1, 2, 3 FC−SW CLARiiON
DL58018, ML350(G2)18, ML350(G3)18, ML35018, v2.6.9−42.0.0.0.1.EL AX150
ML370(G2)18, ML37018, ML530(G2)18, ML530(G3)18,
ML53018, ML57018, ML75018
6 Dell PowerEdge: 1800, 2800, 2850, 6800, 6850; Oracle Enterprise PCI Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express QLogic: QLA200−E−SP2, 7, 8, FC−SW CLARiiON
Digital Henge Revo: JS1400, JS2400 v2.6.9−42.0.0.0.1.EL QLA210−E−SP2, 7, 8 AX150
7 Dell PowerEdge: 1800, 2800, 2850 Oracle Enterprise PCI Emulex LP1050−E2, 5, 6, 14; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express QLogic QLA2340−E−SP2, 7, 12 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
8 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Oracle Enterprise PCI Emulex LP1050Ex−E2, 5, 6, 9 FC−AL, EMC Y
6850; Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)35;
LangChao: NC3000, NC3500, NF500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
9 Dell PowerEdge: 1800, 2800, 2850; Oracle Enterprise PCI Emulex LP982−E2, 5, 6 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
Samsung ZSS230 v2.6.9−42.0.0.0.1.EL AX150
10 Samsung ZSS230 Oracle Enterprise PCI Emulex: LP101−E5, 6, 9, LP1050−E5, 6, 14, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express LP982−E5, 6; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic QLA2340−E−SP7, 12
11 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Oracle Enterprise PCI Emulex: LPe111−E2, 4, 5, 6, LPe1150−E2, 5, FC−AL, EMC Y
6850; Linux [32−Bit] 4 U4 Express 6, 10 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)18, DL380(G4)18, DL580(G3)18,
ML350(G4)18, ML370(G4)18;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
12 HPQ Proliant: DL360(G4)18, DL380(G4)18, DL580(G3)18, Oracle Enterprise PCI HPQ A8002A/FC2142SR (LPe1150)2, 5, 6, 31 FC−AL, EMC Y
ML350(G4)18, ML370(G4)18 Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
13 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y39, 40
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express HP c−Class Bladesystem (403621−B21)4, 5, FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL 38 AX150
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
14 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y41
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express HP c−Class Bladesystem (403621−B21)5, 38, FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL 42 AX150
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
15 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ QLogic QMH2462 4Gb FC HBA for HP FC−AL, EMC N
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express c−Class Bladesystem (403619−B21)7, 36 FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
16 HPQ Proliant BL460c: (404664−B21), (416653−B21), Oracle Enterprise PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for FC−AL, EMC Y
(416654−B21), (416655−B21), (416656−B21), Linux [32−Bit] 4 U4 Express HP c−Class Bladesystem (403621−B21)5, 38, FC−SW CLARiiON
(432636−B21); v2.6.9−42.0.0.0.1.EL 42, QLogic QMH2462 4Gb FC HBA for HP AX150
c−Class Bladesystem (403619−B21)7, 36
HPQ Proliant BL465c: (403433−B21), (403434−B21),
(407234−B21), (407235−B21);
HPQ Proliant BL480c: (404704−B21), (416666−B21),
(416667−B21), (416668−B21), (416669−B21)
17 IBM xSeries x3455 (7984) Oracle Enterprise PCI IBM: 42C2069 (LPe11000)2, 5, 6, 31, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express 42C2071 (LPe11002)2, 5, 6, 10; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic: QLE2360−E−SP2, 7, 17,
QLE2362−E−SP2, 7, 17, QLE2462−E−SP2, 7,
11

18 Dell PowerEdge 1950; Oracle Enterprise PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150

11/02/2006 279 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
19 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Oracle Enterprise PCI QLogic QLE2360−E−SP2, 7, 16, 17 FC−AL, EMC Y
6850; Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)35;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
20 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise PCI QLogic QLE2360−E−SP7, 16, 17 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, NF520; v2.6.9−42.0.0.0.1.EL AX150
Samsung ZSS230
21 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Oracle Enterprise PCI QLogic QLE2460−E−SP2, 7, 11 FC−AL, EMC Y
6850; Linux [32−Bit] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
22 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, QLogic: QLA200−E−SP2, 7, 8, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X QLA210−E−SP2, 7, 8 AX150
HPQ Proliant ML350(G4)18;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
23 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP1050−E2, 5, 6, 14; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, QLogic QLA2340−E−SP2, 7, 12 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX150
IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
24 Dell PowerEdge: 2900, 2950, 6800, 6850, 6950; Oracle Enterprise PCI Emulex LP982−E2, 5, 6 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
25 HPQ Proliant ML350(G4)18 Oracle Enterprise PCI Emulex: LP1050−E5, 6, 14, LP982−E5, 6; FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 7, 30, AX150
AE369A/FC1243 (QLA2462)2, 7, 30;
QLogic QLA2340−E−SP7, 12
26 Dell PowerEdge: 2900, 2950, 6950; Oracle Enterprise PCI Emulex: LP1050Ex−E2, 5, 6, 9, LPe111−E2, 4, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 5, 6, LPe1150−E2, 5, 6, 10; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−42.0.0.0.1.EL PCI−X AX150
QLogic: QLE2360−E−SP2, 7, 16, 17 ,
IBM eServer 326m (Model 7969); QLE2460−E−SP2, 7, 11
Intel: SR1500/S5000PAL, SR2500/S5000PAL
27 IBM xSeries: x3550 (7978), x3650 (7979), x3755 (8877) Oracle Enterprise PCI IBM: 24P0960 (QLA2340)2, 7, 12, 22 , FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, 24P8053 (QLA2342)2, 7, 12; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
QLogic: QLA2460−E−SP2, 7, 11,
QLE2360−E−SP2, 7, 24, QLE2460−E−SP2, 7,
23

28 NEC Express 5800: 120Li, 120Rg−1, 120Ri−2, 140Hf, Oracle Enterprise PCI NEC: N8190−120 (LP1050)5, 14, 19, 20 , FC−AL, EMC Y
140Re−4 Linux [32−Bit] 4 U4 Express, N8190−127 (LPe1150)5, 10, 19, 20 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
29 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, Oracle Enterprise PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
6850, 6950; Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550, AS2500;
HPQ Proliant ML350(G4)18;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
30 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise PCI Emulex: LP101−E2, 5, 6, 9, LP1050−E5, 6, 14, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, LP982−E5, 6; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X25 AX150
QLogic: QLA200−E−SP2, 7, 8,
QLA210−E−SP2, 7, 8, QLA2340−E−SP7, 12,
QLE220−E−SP1, 2, 3
31 Dell PowerEdge 1855 Oracle Enterprise PCI−X Dell: 2342M7, 12, LPe1105−M2, 5, 6, 10, FC−AL, EMC Y
Linux [32−Bit] 4 U4 QME24622, 7, 32 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
32 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950, 2600, Oracle Enterprise PCI−X Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
2650, 6600, 6650; Linux [32−Bit] 4 U4 QLogic QLA200−E−SP2, 7, 8 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)18, DL360(G4)18,
DL56018, DL74018, DL760 (G2)18, DL76018, ML570(G2)18;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840

11/02/2006 280 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
33 Dell PowerEdge: 2600, 2650, 6600, 6650; Oracle Enterprise PCI−X Emulex LP101−E5, 6, 9 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX150
LangChao: NC3000, NC3500, NF500, NF520
34 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950, 2600, Oracle Enterprise PCI−X Emulex LP1050−E2, 5, 6, 14 FC−AL, EMC Y
2650, 6600, 6650; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)35, x346 (8840)35;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
35 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600, 2650, Oracle Enterprise PCI−X Emulex LP982−E2, 5, 6 FC−AL, EMC Y
6600, 6650; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)35, x346 (8840)35;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
36 Dell PowerEdge: 2600, 2650, 6600, 6650; Oracle Enterprise PCI−X Emulex: LP1050−E5, 6, 14, LP982−E5, 6 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant: BL40p, DL360(G3)18, DL360(G4)18,
DL56018, DL760 (G2)18, DL76018, ML570(G2)18;
LangChao: NC3000, NC3500, NF500, NF520;
Samsung: SS370, SS3840
37 HPQ Proliant DL360(G4)18 Oracle Enterprise PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 7, 30, FC−AL, EMC Y
Linux [32−Bit] 4 U4 AE369A/FC1243 (QLA2462)2, 7, 30 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
38 NEC Express 5800: 120Lh, 120Re−1, 120Rf−1, 120Rg−2, Oracle Enterprise PCI−X NEC N8190−120 (LP1050)5, 6, 9, 20 FC−AL, EMC Y
120Rh−2, 140He, 140Rd−4 Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
39 NEC Express 5800: 140He, 140Rd−4 Oracle Enterprise PCI−X NEC N8190−127 (LPe1150)5, 6, 20, 31 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
40 Dell PowerEdge: 2600, 2650, 6600, 6650 Oracle Enterprise PCI−X QLogic QLA200−E−SP7, 8 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
41 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 2600, 2650, Oracle Enterprise PCI−X QLogic QLA210−E−SP2, 7, 8 FC−AL, EMC Y
6600, 6650; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)18, DL360(G4)18,
DL56018, DL74018, DL760 (G2)18, DL76018, ML570(G2)18;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
42 Dell PowerEdge: 1600SC, 1650, 1750, 1850, 1950; Oracle Enterprise PCI−X QLogic QLA2340−E−SP2, 7, 12 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX150
IBM xSeries: x255, x336 (8837)35, x346 (8840)35;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150, ZSS230;
Sun: V20z, V40z, x4100, x4200
43 Dell PowerEdge: 2600, 2650, 6600, 6650; Oracle Enterprise PCI−X QLogic QLA2340−E−SP7, 12 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)18, DL360(G4)18,
DL56018, DL74018, DL760 (G2)18, DL76018, ML570(G2)18;
LangChao: NC2000, NC3000, NC3500, NF420, NF500,
NF520;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840

11/02/2006 281 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
44 Sun: x4100, x4200 Oracle Enterprise PCI−X QLogic QLA2460−E−SP2, 7, 11 FC−AL, EMC Y
Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
45 Digital Henge SH4500R4; Oracle Enterprise PCI−X QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; Linux [32−Bit] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant: BL40p, DL360(G3)18, DL360(G4)18,
DL56018, DL74018, DL760 (G2)18, DL76018, ML570(G2)18;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
46 Dell PowerEdge 1955 Oracle Enterprise PCI, PCI Dell: LPe1105−M2, 5, 6, 10, QME24622, 7, 32 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
47 HPQ Proliant: DL380(G5), DL580(G4) Oracle Enterprise PCI, PCI Emulex: LP101−E2, 5, 6, 9, LP1050−E5, 6, 14, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, LP982−E5, 6, LPe111−E2, 4, 5, 6, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X LPe1150−E2, 5, 6, 10; AX150
HPQ: A8002A/FC2142SR (LPe1150)2, 5, 6,
31, AE311A/FC1142SR (QLE2460)2, 7, 11,
AE312A/FC1242SR (QLE2462)2, 7, 11;
QLogic: QLA200−E−SP2, 7, 8,
QLA210−E−SP2, 7, 8, QLA2340−E−SP7, 12,
QLE2460−E−SP2, 7, 11, QLE2462−E−SP2, 7,
11

48 HPQ Proliant DL380(G5) Oracle Enterprise PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 7, 30, FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, AE369A/FC1243 (QLA2462)2, 7, 30 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
49 Dell PowerEdge: 1800, 2800; Oracle Enterprise PCI, PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
Linux [32−Bit] 4 U4 Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) v2.6.9−42.0.0.0.1.EL PCI−X AX150
50 HPQ Proliant: DL14518, DL380(G2)18, DL380(G3)18, Oracle Enterprise PCI, Emulex LP101−E2, 5, 6, 9; FC−AL, EMC Y
DL380(G4)18, DL38018, DL38518, DL580(G2)18, Linux [32−Bit] 4 U4 PCI−X QLogic: QLA200−E−SP2, 7, 8, FC−SW CLARiiON
DL580(G3)18, DL58518, ML370(G3)18, ML370(G4)18; v2.6.9−42.0.0.0.1.EL QLA210−E−SP2, 7, 8, QLE220−E−SP1, 2, 3 AX150
Samsung SS140
51 Dell PowerEdge: 1800, 1850, 2800, 2850; Oracle Enterprise PCI, Emulex: LP1050−E2, 5, 6, 14, LP982−E2, 5, 6; FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model 8848); v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP2, 7, 12 AX150
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
52 HPQ Proliant: DL14518, DL380(G2)18, DL380(G3)18, Oracle Enterprise PCI, Emulex: LP1050−E5, 6, 14, LP982−E5, 6 FC−AL, EMC Y
DL380(G4)18, DL38018, DL38518, DL580(G2)18, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
DL580(G3)18, DL58518, ML370(G3)18, ML370(G4)18 v2.6.9−42.0.0.0.1.EL AX150
53 HPQ Proliant: DL380(G4)18, DL38518, DL58518, Oracle Enterprise PCI, HPQ: AB429A/FC1143 (QLA2460)2, 7, 30, FC−AL, EMC Y
ML370(G4)18 Linux [32−Bit] 4 U4 PCI−X AE369A/FC1243 (QLA2462)2, 7, 30 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
54 IBM eServer: 325 (Model 8835), 326 (Model 8848) Oracle Enterprise PCI, IBM 24P0960 (QLA2340)2, 7, 12, 22 FC−AL, EMC Y
Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
55 HPQ Proliant: DL14518, DL380(G4)18, DL38518, Oracle Enterprise PCI, QLogic QLA2340−E−SP7, 12 FC−AL, EMC Y
DL580(G2)18, DL580(G3)18, DL58518, ML370(G3)18, Linux [32−Bit] 4 U4 PCI−X FC−SW CLARiiON
ML370(G4)18; v2.6.9−42.0.0.0.1.EL AX150
Samsung SS140
56 Bull NovaScale 2320 Oracle Enterprise PCI−X Bull 2Gbps FC Mezzanine Card − Dual port FC−SW EMC Y
Linux [32−Bit] 4 U4 for NovaScale Blade Series: CLARiiON
v2.6.9−42.0.0.0.1.EL CFSN202−11007, 13, CFSN202−11007, 21; AX150
Bull 2Gbps FC Mezzanine Card − Dual port
mini for NovaScale Blade 2021:
CFSN202−21007, 13, CFSN202−21007, 21;
Bull SBEFCM (SFF) Mezzanine: HBA2, 7, 21,
HBA7, 13;
Bull SBEFCM4 (SFF) 4Gb Mezzanine HBA7,
15

57 Digital Henge PowerBlade BS200L Oracle Enterprise PCI−X Digital Henge Digital Henge: SBEFCM42, 7, FC−SW EMC Y
Linux [32−Bit] 4 U4 15, SBEFCM7, 13, SBFCM7, 13; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge Intel (r) Fibre Channel Module
AHWFCMOD2, 7, 13
58 IBM BladeCenter: HS20 (Model 8843), HS21 (Model Oracle Enterprise PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8853)27 Linux [32−Bit] 4 U4 (26R0890)2, 7, 28, 29 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
59 IBM BladeCenter: HS21 (Model 8853)27, LS20 (Model Oracle Enterprise PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
8850), LS21 (Model 7971), LS41 (Model 7972) Linux [32−Bit] 4 U4 (26R0890)2, 7, 29 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
60 IBM BladeCenter: HS20 (Model 8843), LS20 (Model 8850), Oracle Enterprise PCI−X IBM HS20 FC Exp Card (26K4841)2, 7, 12 FC−SW EMC Y
LS21 (Model 7971), LS41 (Model 7972) Linux [32−Bit] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
61 IBM BladeCenter HS20 (Model: 7981), 8678)34, 8832)34, Oracle Enterprise PCI−X IBM HS20 FC Exp Card: (13N2203)2, 7, 12, FC−SW EMC Y
8832−N1X), 8843); Linux [32−Bit] 4 U4 (48P7061)2, 7, 12 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
IBM BladeCenter: HS21 (Model 8853)27, HS40 (Model
8839)

11/02/2006 282 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
62 IBM BladeCenter LS20 (Model 8850) Oracle Enterprise PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM FC−SW EMC Y
Linux [32−Bit] 4 U4 eServer LS202, 7, 12, SFF Exp Card CLARiiON
v2.6.9−42.0.0.0.1.EL (26K4841) for IBM eServer LS202, 7, 12 AX150
63 IBM BladeCenter HS20 (Model: 7981), 8678)34, 8832)34, Oracle Enterprise PCI−X IBM: Emulex LP1005DC FC Exp Card2, 5, 6, FC−SW EMC Y
8832−N1X), 8843); Linux [32−Bit] 4 U4 33, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−42.0.0.0.1.EL (26R0884)2, 7, 37 AX150
IBM BladeCenter: HS40 (Model 8839), LS20 (Model 8850)
1. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
2. SNIA HBA API Supported.
3. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
4. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Driver Version 8.0.16.27 Driver is integrated into the kernel.
6. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
8. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. Firmware Version 2.50a6
11. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com
14. Firmware Version 1.91a5
15. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
16. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
19. BIOS 1.70a3
20. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
21. BIOS 1.43
22. This HBA is equivalent to the QLogic QLA2340.
23. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
25. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
26. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
27. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
28. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
29. BIOS 1.12
30. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
31. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
34. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
35. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
36. BIOS 1.16
37. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
38. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
39. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
40. VxVM is not supported on servers booting from the array.
41. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
42. Firmware Version 2.50a8

Oracle Enterprise Linux [AMD−64]

Oracle Enterprise Linux [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 IBM xSeries x3455 (7984) Oracle Enterprise Linux PCI Emulex: LP10000ExDC−E1, 4, 6, 23, LP1050Ex−E1, 4, 5, 6; FC−AL, EMC Y
[AMD−64] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL IBM: 42C2069 (LPe11000)1, 4, 6, 22, 42C2071 (LPe11002)1, 4, 6, 9; AX150
QLogic: QLE2360−E−SP1, 3, 25, QLE2460−E−SP1, 3, 24
2 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y13, 14
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express Bladesystem (403621−B21)4, 15, 16 FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL AX150
3 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y28
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express Bladesystem (403621−B21)4, 16, 27 FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL AX150
4 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express (403619−B21)3, 26 FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL AX150
5 HPQ Proliant BL465c: Oracle Enterprise Linux PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y
(403433−B21), (403434−B21), [AMD−64] 4 U4 Express Bladesystem (403621−B21)4, 16, 27, QLogic QMH2462 4Gb FC FC−SW CLARiiON
(407234−B21), (407235−B21) v2.6.9−42.0.0.0.1.EL HBA for HP c−Class Bladesystem (403619−B21)3, 26 AX150
6 Dell PowerEdge 6950; Oracle Enterprise Linux PCI Emulex LP1050−E1, 4, 6, 17; FC−AL, EMC Y
IBM xSeries x3755 (8877) [AMD−64] 4 U4 Express, QLogic QLA2340−E−SP1, 3, 18 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
7 Dell PowerEdge 6950 Oracle Enterprise Linux PCI Emulex: LP101−E1, 4, 5, 6, LP982−E1, 4, 6; FC−AL, EMC Y
[AMD−64] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X QLogic: QLA200−E−SP1, 2, 3, QLA210−E−SP1, 2, 3, AX150
QLE220−E−SP1, 20, 21
8 Dell PowerEdge 6950; Oracle Enterprise Linux PCI Emulex: LP1050Ex−E1, 4, 5, 6, LPe111−E1, 4, 6, 15, LPe1150−E1, 4, FC−AL, EMC Y
IBM eServer 326m (Model [AMD−64] 4 U4 Express, 6, 9; FC−SW CLARiiON
7969) v2.6.9−42.0.0.0.1.EL PCI−X AX150
QLogic: QLE2360−E−SP1, 3, 11, 12 , QLE2460−E−SP1, 3, 10

11/02/2006 283 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
9 IBM xSeries x3755 (8877) Oracle Enterprise Linux PCI IBM: 24P0960 (QLA2340)1, 3, 18, 32 , 24P8053 (QLA2342)1, 3, 18; FC−AL, EMC Y
[AMD−64] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X QLogic: QLA2460−E−SP1, 3, 24, QLE2360−E−SP1, 3, 25, AX150
QLE2460−E−SP1, 3, 24
10 Sun: V20z, V40z, x4100, x4200 Oracle Enterprise Linux PCI−X Emulex: LP1050−E1, 4, 6, 17, LP982−E1, 4, 6; FC−AL, EMC Y
[AMD−64] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP1, 3, 18 AX150
11 Sun: x4100, x4200 Oracle Enterprise Linux PCI−X QLogic QLA2460−E−SP1, 3, 10 FC−AL, EMC Y
[AMD−64] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
12 HPQ Proliant: DL1457, DL3857, Oracle Enterprise Linux PCI, Emulex: LP101−E1, 4, 5, 6, LP1050−E4, 6, 17, LP982−E4, 6; FC−AL, EMC Y
DL5857 [AMD−64] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic: QLA200−E−SP1, 2, 3, QLA210−E−SP1, 2, 3, AX150
QLA2340−E−SP3, 18, QLE220−E−SP1, 19, 20, 21
13 IBM eServer: 325 (Model 8835), Oracle Enterprise Linux PCI, Emulex: LP1050−E1, 4, 6, 17, LP982−E1, 4, 6; FC−AL, EMC Y
326 (Model 8848) [AMD−64] 4 U4 PCI−X FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL IBM 24P0960 (QLA2340)1, 3, 18, 32 ; AX150
QLogic QLA2340−E−SP1, 3, 18
14 IBM BladeCenter LS20 (Model Oracle Enterprise Linux PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)1, 4, 29, FC−SW EMC Y
8850) [AMD−64] 4 U4 30, LP1005DC FC Exp Card1, 4, 6, 31 ; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
IBM HS20 4GB: SFF FC Exp Card (26R0890)1, 3, 8, Standard FC
Exp Card (26R0884)1, 3, 33;
IBM HS20 FC Exp Card: (13N2203) for IBM eServer LS201, 3, 18,
(26K4841)1, 3, 18;
IBM HS20 FC SFF Exp Card (26K4841) for IBM eServer LS201, 3,
18

1. SNIA HBA API Supported.


2. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
4. Driver Version 8.0.16.27 Driver is integrated into the kernel.
5. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
6. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
7. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
8. BIOS 1.12
9. Firmware Version 2.50a6
10. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
14. VxVM is not supported on servers booting from the array.
15. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
16. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
17. Firmware Version 1.91a5
18. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Driver/BIOS are available at http://www.qlogic.com
20. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
21. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
22. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
23. Firmware Version 1.91.a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
25. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
26. BIOS 1.16
27. Firmware Version 2.50a8
28. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
29. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
31. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. This HBA is equivalent to the QLogic QLA2340.
33. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

Oracle Enterprise Linux [EM64T]

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, 2800, 2850, 6800, Oracle Enterprise Linux PCI Emulex LP101−E3, 5, 14, 25 ; FC−AL, EMC Y
6850; [EM64T] 4 U4 Express QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge Revo: JS1400, JS2400
2 Dell PowerEdge: 1800, 2800, 2850 Oracle Enterprise Linux PCI Emulex LP1050−E3, 5, 6, 14; FC−AL, EMC Y
[EM64T] 4 U4 Express QLogic QLA2340−E−SP3, 8, 10 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
3 Dell PowerEdge: 1800, 1850, 1950, 2800, Oracle Enterprise Linux PCI Emulex LP1050Ex−E3, 5, 14, 25 FC−AL, EMC Y
2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)35;
LangChao: NC3000, NC3500, NF500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 284 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
4 Dell PowerEdge: 1800, 2800, 2850; Oracle Enterprise Linux PCI Emulex LP982−E3, 5, 14 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
Samsung ZSS230 v2.6.9−42.0.0.0.1.EL AX150
5 Samsung ZSS230 Oracle Enterprise Linux PCI Emulex: LP101−E5, 14, 25, LP1050−E5, 6, 14, FC−AL, EMC Y
[EM64T] 4 U4 Express LP982−E5, 14; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic QLA2340−E−SP8, 10
6 Dell PowerEdge: 1800, 1850, 1950, 2800, Oracle Enterprise Linux PCI Emulex: LPe111−E3, 5, 14, 33 , LPe1150−E3, 5, 14, 21 FC−AL, EMC Y
2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)11,
DL380(G4)11, DL580(G3)11,
ML350(G4)11, ML370(G4)11;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
7 HPQ Proliant: DL360(G4)11, Oracle Enterprise Linux PCI HPQ A8002A/FC2142SR (LPe1150)3, 5, 14, 22 FC−AL, EMC Y
DL380(G4)11, DL580(G3)11, [EM64T] 4 U4 Express FC−SW CLARiiON
ML350(G4)11, ML370(G4)11 v2.6.9−42.0.0.0.1.EL AX150
8 Dell PowerEdge 1950 Oracle Enterprise Linux PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
9 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise Linux PCI QLogic QLE220−E−SP1, 2, 3, 12 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
10 Dell PowerEdge: 1800, 1850, 1950, 2800, Oracle Enterprise Linux PCI QLogic QLE2360−E−SP3, 8, 26, 27 FC−AL, EMC Y
2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)35;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
11 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise Linux PCI QLogic QLE2360−E−SP8, 26, 27 FC−AL, EMC Y
[EM64T] 4 U4 Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−42.0.0.0.1.EL AX150
NF520;
Samsung ZSS230
12 Dell PowerEdge: 1800, 1850, 1950, 2800, Oracle Enterprise Linux PCI QLogic QLE2460−E−SP3, 8, 24 FC−AL, EMC Y
2850, 6800, 6850; [EM64T] 4 U4 Express FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
13 Dell PowerEdge: 2900, 2950, 6800, 6850; Oracle Enterprise Linux PCI Emulex LP101−E3, 5, 14, 25 ; FC−AL, EMC Y
[EM64T] 4 U4 Express, QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−42.0.0.0.1.EL PCI−X AX150
AS2500;
HPQ Proliant ML350(G4)11;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
14 Dell PowerEdge: 2900, 2950, 6800, 6850; Oracle Enterprise Linux PCI Emulex LP1050−E3, 5, 6, 14; FC−AL, EMC Y
[EM64T] 4 U4 Express, QLogic QLA2340−E−SP3, 8, 10 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−42.0.0.0.1.EL PCI−X AX150
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
15 Dell PowerEdge: 2900, 2950, 6800, 6850; Oracle Enterprise Linux PCI Emulex LP982−E3, 5, 14 FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−42.0.0.0.1.EL PCI−X AX150
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
16 HPQ Proliant ML350(G4)11 Oracle Enterprise Linux PCI Emulex: LP1050−E5, 6, 14, LP982−E5, 14; FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)3, 8, 20, AX150
AE369A/FC1243 (QLA2462)3, 8, 20;
QLogic: QLA2340−E−SP8, 10, QLE220−E−SP1, 2, 3, 12

11/02/2006 285 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
17 Dell PowerEdge: 2900, 2950; Oracle Enterprise Linux PCI Emulex: LP1050Ex−E3, 5, 14, 25 , LPe111−E3, 5, 14, 33 , FC−AL, EMC Y
[EM64T] 4 U4 Express, LPe1150−E3, 5, 14, 21 ; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−42.0.0.0.1.EL PCI−X AX150
AS2500; QLogic: QLE2360−E−SP3, 8, 26, 27 , QLE2460−E−SP3,
8, 24
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
18 IBM xSeries: x3550 (7978), x3650 (7979) Oracle Enterprise Linux PCI IBM: 24P0960 (QLA2340)3, 8, 10, 37 , 24P8053 FC−AL, EMC Y
[EM64T] 4 U4 Express, (QLA2342)3, 8, 10; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
QLogic: QLA2460−E−SP3, 8, 38, QLE2360−E−SP3, 8,
39, QLE2460−E−SP3, 8, 38

19 NEC Express 5800: 120Li, 120Rg−1, Oracle Enterprise Linux PCI NEC: N8190−120 (LP1050)4, 5, 6, 7, N8190−127 FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 [EM64T] 4 U4 Express, (LPe1150)4, 5, 7, 21 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
20 Dell PowerEdge: 1850, 1900, 2850, 2900, Oracle Enterprise Linux PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
2950, 6800, 6850; [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
21 Digital Henge Revo: JS1400, JS2400 Oracle Enterprise Linux PCI Emulex: LP101−E3, 5, 14, 25 , LP1050−E5, 6, 14, FC−AL, EMC Y
[EM64T] 4 U4 Express, LP982−E5, 14; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X13 AX150
QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9,
QLA2340−E−SP8, 10, QLE220−E−SP1, 2, 3, 12
22 Dell PowerEdge 1855 Oracle Enterprise Linux PCI−X Dell: 2342M8, 10, LPe1105−M3, 5, 14, 21 , QME24623, 8, FC−AL, EMC Y
[EM64T] 4 U4 23 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
23 Dell PowerEdge: 1850, 1950; Oracle Enterprise Linux PCI−X Emulex LP101−E3, 5, 14, 25 ; FC−AL, EMC Y
[EM64T] 4 U4 QLogic QLA200−E−SP3, 8, 9 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant DL360(G4)11;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003
24 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise Linux PCI−X Emulex LP101−E5, 14, 25 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−42.0.0.0.1.EL AX150
NF520
25 Dell PowerEdge: 1850, 1950; Oracle Enterprise Linux PCI−X Emulex LP1050−E3, 5, 6, 14; FC−AL, EMC Y
[EM64T] 4 U4 QLogic QLA2340−E−SP3, 8, 10 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX150
IBM xSeries: x255, x336 (8837)35, x346
(8840)35;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230
26 Dell PowerEdge 1850; Oracle Enterprise Linux PCI−X Emulex LP982−E3, 5, 14 FC−AL, EMC Y
Digital Henge INNO: HR−4850, HR−6850; [EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)35, x346
(8840)35;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003,
T650;
Samsung: SS210, SS370, SS3840,
ZSS150, ZSS230
27 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise Linux PCI−X Emulex: LP1050−E5, 6, 14, LP982−E5, 14 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
HPQ Proliant DL360(G4)11; v2.6.9−42.0.0.0.1.EL AX150
LangChao: NC3000, NC3500, NF500,
NF520
28 HPQ Proliant BL460c: (416653−B21), Oracle Enterprise Linux PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y30, 31
(416654−B21), (416655−B21), [EM64T] 4 U4 c−Class Bladesystem (403621−B21)5, 29, 32 FC−SW CLARiiON
(416656−B21), (432636−B21); v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
29 HPQ Proliant BL460c: (416653−B21), Oracle Enterprise Linux PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(416654−B21), (416655−B21), [EM64T] 4 U4 Bladesystem (403619−B21)8, 28 FC−SW CLARiiON
(416656−B21), (432636−B21); v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)

11/02/2006 286 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [EM64T]


Storage External
No. Host System Operating System Host Bus Host Bus Adapter Topology Array Boot
30 HPQ Proliant DL360(G4)11 Oracle Enterprise Linux PCI−X HPQ: AB429A/FC1143 (QLA2460)3, 8, 20, FC−AL, EMC Y
[EM64T] 4 U4 AE369A/FC1243 (QLA2462)3, 8, 20 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
31 NEC Express 5800: 120Lh, 120Re−1, Oracle Enterprise Linux PCI−X NEC N8190−120 (LP1050)4, 5, 14, 25 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, [EM64T] 4 U4 FC−SW CLARiiON
140Rd−4 v2.6.9−42.0.0.0.1.EL AX150
32 NEC Express 5800: 140He, 140Rd−4 Oracle Enterprise Linux PCI−X NEC N8190−127 (LPe1150)4, 5, 14, 22 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
33 Dell PowerEdge 1850; Oracle Enterprise Linux PCI−X QLogic QLA210−E−SP3, 8, 9 FC−AL, EMC Y
Digital Henge SH4500R4; [EM64T] 4 U4 FC−SW CLARiiON
HPQ Proliant DL360(G4)11; v2.6.9−42.0.0.0.1.EL AX150
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003
34 Digital Henge INNO: HR−4850, HR−6850; Oracle Enterprise Linux PCI−X QLogic QLA2340−E−SP8, 10 FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−42.0.0.0.1.EL AX150
11
HPQ Proliant DL360(G4) ;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer: R630 6004, T630
6003
35 Digital Henge SH4500R4; Oracle Enterprise Linux PCI−X QLogic QLE220−E−SP1, 2, 3, 12 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, [EM64T] 4 U4 FC−SW CLARiiON
TX200 S2, TX300 S2; v2.6.9−42.0.0.0.1.EL AX150
HPQ Proliant DL360(G4)11;
LangChao NF420;
Lenovo SureServer: R630 6004, T630
6003
36 Dell PowerEdge 1955 Oracle Enterprise Linux PCI, PCI Dell: LPe1105−M3, 5, 14, 21 , QME24623, 8, 23 FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
37 HPQ Proliant DL380(G5) Oracle Enterprise Linux PCI, PCI Emulex: LP101−E3, 5, 14, 25 , LP1050−E5, 6, 14, FC−AL, EMC Y
[EM64T] 4 U4 Express, LP982−E5, 14; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)3, 8, 20,
AE369A/FC1243 (QLA2462)3, 8, 20;
QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9,
QLA2340−E−SP8, 10
38 HPQ Proliant: DL380(G5), DL580(G4) Oracle Enterprise Linux PCI, PCI Emulex: LPe111−E3, 5, 14, 33 , LPe1150−E3, 5, 14, 21 ; FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X HPQ: A8002A/FC2142SR (LPe1150)3, 5, 14, 22 , AX150
AE311A/FC1142SR (QLE2460)3, 8, 24,
AE312A/FC1242SR (QLE2462)3, 8, 24;
QLogic: QLE2460−E−SP3, 8, 24, QLE2462−E−SP3, 8,
24

39 Dell PowerEdge: 1800, 2800 Oracle Enterprise Linux PCI, PCI QLogic QLE220−E−SP1, 2, 3 FC−AL, EMC Y
[EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
40 HPQ Proliant: DL380(G5), DL580(G3)11, Oracle Enterprise Linux PCI, PCI QLogic QLE220−E−SP1, 2, 3, 12 FC−AL, EMC Y
DL580(G4) [EM64T] 4 U4 Express, FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL PCI−X AX150
41 HPQ Proliant: DL380(G4)11, Oracle Enterprise Linux PCI, PCI−X Emulex: LP101−E3, 5, 14, 25 , LP1050−E5, 6, 14, FC−AL, EMC Y
ML370(G4)11 [EM64T] 4 U4 LP982−E5, 14; FC−SW CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
HPQ: AB429A/FC1143 (QLA2460)3, 8, 20,
AE369A/FC1243 (QLA2462)3, 8, 20;
QLogic: QLA200−E−SP3, 8, 9, QLA210−E−SP3, 8, 9,
QLA2340−E−SP8, 10, QLE220−E−SP1, 2, 3, 12
42 Dell PowerEdge: 1800, 1850, 2800, 2850; Oracle Enterprise Linux PCI, PCI−X Emulex: LP1050−E3, 5, 6, 14, LP982−E3, 5, 14; FC−AL, EMC Y
[EM64T] 4 U4 FC−SW CLARiiON
IBM xSeries: x365, x440, x445 (8870); v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP3, 8, 10 AX150
Samsung: ES470, ES570, SS140
43 IBM BladeCenter HS20 (Model 8843) Oracle Enterprise Linux PCI−X IBM HS20 FC Exp Card (26K4841)3, 8, 10 FC−SW EMC Y
[EM64T] 4 U4 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
44 IBM BladeCenter HS20 (Model: Oracle Enterprise Linux PCI−X IBM HS20 FC Exp Card: (13N2203)3, 8, 10, FC−SW EMC Y
8832−N1X), 8843); [EM64T] 4 U4 (48P7061)3, 8, 10 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
IBM BladeCenter HS21 (Model 8853)17
45 IBM BladeCenter: HS20 (Model 8843), Oracle Enterprise Linux PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
HS21 (Model 8853)17 [EM64T] 4 U4 (39Y9186)3, 5, 15, 16 , HS20 4GB SFF FC Exp Card CLARiiON
v2.6.9−42.0.0.0.1.EL (26R0890)3, 8, 18, 19 AX150
46 IBM BladeCenter HS20 (Model: Oracle Enterprise Linux PCI−X IBM: Emulex LP1005DC FC Exp Card3, 5, 14, 34 , HS20 FC−SW EMC Y
8832−N1X), 8843) [EM64T] 4 U4 4GB Standard FC Exp Card (26R0884)3, 8, 36 CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
1. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
2. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
3. SNIA HBA API Supported.
4. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
5. Driver Version 8.0.16.27 Driver is integrated into the kernel.
6. Firmware Version 1.91a5
7. BIOS 1.70a3
8. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
9. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
12. Driver/BIOS are available at http://www.qlogic.com
13. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
14. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

11/02/2006 287 CLARiiON AX150


CLARiiON AX150

15. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
16. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
17. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
18. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. BIOS 1.12
20. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Firmware Version 2.50a6
22. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
23. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
26. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
27. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
28. BIOS 1.16
29. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
31. VxVM is not supported on servers booting from the array.
32. Firmware Version 2.50a8
33. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
34. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
36. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. This HBA is equivalent to the QLogic QLA2340.
38. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
39. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com

Red Flag DC Server [32−Bit]

Red Flag DC Server [32−Bit]


Host Bus Storage External
No. Host System Operating System Host Bus Adapter Topology Array Boot
1 HPQ Proliant: DL3207, DL360(G2)7, DL3607, DL380(G2)7, DL380(G3)7, DL3807, Red Flag DC Server PCI QLogic FC−AL, EMC Y
DL580(G2)7, DL5807, ML350(G2)7, ML350(G3)7, ML3507, ML370(G2)7, ML3707, [32−Bit] 5.0 SP1 QLE220−E−SP3, FC−SW CLARiiON
ML530(G2)7, ML530(G3)7, ML5307, ML5707, ML7507 v2.6.9−34.21AX5, 6 8, 9, 10 AX150
2 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, 6850; Red Flag DC Server PCI Emulex FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express LPe111−E1, 2, FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.21AX5, 6 3, 4 AX150
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)7, DL380(G4)7, DL580(G3)7, ML350(G4)7, ML370(G4)7;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
3 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 8, 9, 10 AX150
4 Dell PowerEdge 1950 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 9, 10 AX150
5 Dell PowerEdge: 2900, 2950, 6950; Red Flag DC Server PCI Emulex FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, LPe111−E1, 2, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX5, 6 PCI−X 3, 4 AX150
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL, SR2500/S5000PAL
6 HPQ Proliant ML350(G4)7 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 PCI−X 8, 9, 10 AX150
7 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, 6850, 6950; Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.9−34.21AX5, 6 PCI−X 9, 10 AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
8 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 PCI−X11 8, 9, 10 AX150
9 Digital Henge SH4500R4; Red Flag DC Server PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, TX300 S2; [32−Bit] 5.0 SP1 QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 8, 9, 10 AX150
HPQ Proliant: BL40p, DL360(G3)7, DL360(G4)7, DL5607, DL7407, DL760 (G2)7,
DL7607, ML570(G2)7;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
10 Dell PowerEdge: 1800, 2800 Red Flag DC Server PCI, PCI QLogic FC−AL, EMC Y
[32−Bit] 5.0 SP1 Express, QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 PCI−X 9, 10 AX150
11 HPQ Proliant: DL1457, DL380(G2)7, DL380(G3)7, DL380(G4)7, DL3807, DL3857, Red Flag DC Server PCI, QLogic FC−AL, EMC Y
DL580(G2)7, DL580(G3)7, DL5857, ML370(G3)7, ML370(G4)7; [32−Bit] 5.0 SP1 PCI−X QLE220−E−SP3, FC−SW CLARiiON
v2.6.9−34.21AX5, 6 8, 9, 10 AX150
Samsung SS140

11/02/2006 288 CLARiiON AX150


CLARiiON AX150

1. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. Driver Version 8.0.16.18 Driver is integrated into the kernel.
3. SNIA HBA API Supported.
4. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Native multipathing is not supported on boot−from−SAN configurations.
6. Based on Asianux 2.0.
7. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
8. Driver/BIOS are available at http://www.qlogic.com
9. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
10. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Red Flag DC Server [AMD64]

Red Flag DC Server [AMD64]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge 6950; Red Flag DC Server [AMD64] 5.0 SP1 PCI Express, Emulex LPe111−E3, 4, 5, 13 FC−AL, EMC CLARiiON Y
IBM eServer 326m (Model v2.6.9−34.21AX1, 2 PCI−X FC−SW AX150
7969)
2 Dell PowerEdge 6950 Red Flag DC Server [AMD64] 5.0 SP1 PCI Express, QLogic QLE220−E−SP4, 8, 9 FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX1, 2 PCI−X FC−SW AX150
3 Sun: x4100, x4200 Red Flag DC Server [AMD64] 5.0 SP1 PCI−X Emulex: LP1050−E3, 4, 5, 12, FC−AL, EMC CLARiiON Y
v2.6.9−34.21AX1, 2 LP982−E3, 4, 5; FC−SW AX150
QLogic QLA2340−E−SP4, 6, 7
4 HPQ Proliant: DL14510, Red Flag DC Server [AMD64] 5.0 SP1 PCI, PCI−X QLogic QLE220−E−SP4, 8, 9, 11 FC−AL, EMC CLARiiON Y
DL38510, DL58510 v2.6.9−34.21AX1, 2 FC−SW AX150
1. Native multipathing is not supported on boot−from−SAN configurations.
2. Based on Asianux 2.0.
3. Driver Version 8.0.16.18 Driver is integrated into the kernel.
4. SNIA HBA API Supported.
5. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
6. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
7. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
9. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
10. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
11. Driver/BIOS are available at http://www.qlogic.com
12. Firmware Version 1.91a5
13. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

Red Flag DC Server [EM64T]

Red Flag DC Server [EM64T]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
1 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, 6800, Red Flag DC Server [EM64T] 5.0 PCI Express Emulex LPe111−E6, FC−AL, EMC Y
6850; SP1 v2.6.9−34.21AX2, 3 7, 8, 9 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)10, DL380(G4)10,
DL580(G3)10, ML350(G4)10, ML370(G4)10;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
2 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server [EM64T] 5.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
3 Dell PowerEdge 1950 Red Flag DC Server [EM64T] 5.0 PCI Express QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP4, 5, FC−SW CLARiiON
6 AX150
4 Dell PowerEdge: 2900, 2950; Red Flag DC Server [EM64T] 5.0 PCI Express, Emulex LPe111−E6, FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X 7, 8, 9 FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, AS2500; AX150
Intel: SR1500/S5000PAL, SR2500/S5000PAL
5 HPQ Proliant ML350(G4)10 Red Flag DC Server [EM64T] 5.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
6 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, 6800, Red Flag DC Server [EM64T] 5.0 PCI Express, QLogic FC−AL, EMC Y
6850; SP1 v2.6.9−34.21AX2, 3 PCI−X QLE220−E−SP4, 5, FC−SW CLARiiON
6 AX150
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
7 Digital Henge Revo: JS1400, JS2400 Red Flag DC Server [EM64T] 5.0 PCI Express, QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 PCI−X11 QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150

11/02/2006 289 CLARiiON AX150


CLARiiON AX150

Red Flag DC Server [EM64T]


External
No. Host System Operating System Host Bus Host Bus Adapter Topology Storage Array Boot
8 Digital Henge SH4500R4; Red Flag DC Server [EM64T] 5.0 PCI−X QLogic FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 S2, SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP1, 4, FC−SW CLARiiON
TX300 S2; 5, 6 AX150
HPQ Proliant DL360(G4)10;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003
9 HPQ Proliant DL580(G3)10 Red Flag DC Server [EM64T] 5.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 Express, PCI−X QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
10 Dell PowerEdge: 1800, 2800 Red Flag DC Server [EM64T] 5.0 PCI, PCI QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 Express, PCI−X QLE220−E−SP4, 5, FC−SW CLARiiON
6 AX150
11 HPQ Proliant: DL380(G4)10, ML370(G4)10 Red Flag DC Server [EM64T] 5.0 PCI, PCI−X QLogic FC−AL, EMC Y
SP1 v2.6.9−34.21AX2, 3 QLE220−E−SP1, 4, FC−SW CLARiiON
5, 6 AX150
1. Driver/BIOS are available at http://www.qlogic.com
2. Native multipathing is not supported on boot−from−SAN configurations.
3. Based on Asianux 2.0.
4. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
5. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
6. SNIA HBA API Supported.
7. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. Driver Version 8.0.16.18 Driver is integrated into the kernel.
9. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
10. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
11. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.

Red Hat RHEL [32−Bit]

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC N11, 47
v2.4.21−32.EL30, 97, 98, for HP Proliant BL20p (G3) CLARiiON
v2.4.21−32.EL30, 98; 361426−B2177, 96, 107 AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
2 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC N11, 47
v2.4.21−32.EL30, 97, 98, for HP Proliant BL30p/BL35p CLARiiON
v2.4.21−32.EL30, 98; 354054−B2177, 107 AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
3 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC Y
v2.4.21−40.EL30, 31 for HP Proliant BL20p (G3) CLARiiON
361426−B2129, 77 AX150
4 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC Y
v2.4.21−40.EL30, 31 for HP Proliant BL30p/BL35p CLARiiON
354054−B2129, 77 AX150
5 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC Y
v2.4.21−47.EL30, 31 for HP Proliant BL20p (G3) CLARiiON
361426−B2144, 77 AX150
6 HPQ Proliant: BL30p, BL35p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC Y
v2.4.21−47.EL30, 31 for HP Proliant BL30p/BL35p CLARiiON
354054−B2144, 77 AX150
7 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES for HP Proliant BL20p (G3) CLARiiON
v2.4.21−37.0.1.EL 361426−B2129, 77 AX150
8 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES for HP Proliant BL30p/BL35p CLARiiON
v2.4.21−37.0.1.EL 354054−B2129, 77 AX150
9 HPQ Proliant BL35p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL EMC Y
v2.4.21−37.EL, U6+ AS/ES for HP Proliant BL30p/BL35p CLARiiON
v2.4.21−37.0.1.EL 354054−B2129, 77 AX150
10 Unisys ES7000/460 [64−Bit] Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Unisys FCH752323−PCX1, 13, 51 FC−AL EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
11 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI QLogic QLA2340−E−SP6 FC−AL, EMC N11, 47
2500, 255065, 4300, 4350, 4400, 6100, v2.4.21−32.EL30, 97, 98 FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL5809, ML350(G2)9, ML350(G3)9, ML3509,
ML370(G2)9, ML3709, ML530(G2)9,
ML530(G3)9, ML5309, ML5709, ML7509
12 IBM xSeries: x225, x230, x232, x240, x250, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI QLogic QLA2340−E−SP6, 95 FC−AL, EMC N11, 47
x330, x335, x340 (4500R), x342, x350 v2.4.21−32.EL30, 97, 98 FC−SW CLARiiON
(6000R), x370 AX150
13 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI QLogic QLA2340−E−SP6 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98 Express, FC−SW CLARiiON
PCI−X AX150

11/02/2006 290 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
14 IBM xSeries x336 (8837)12 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI QLogic QLA2340−E−SP6, 95 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98 Express, FC−SW CLARiiON
PCI−X AX150
15 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI QLogic QLA2340−E−SP6 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98 Express, FC−SW CLARiiON
PCI−X70 AX150
16 Dell PowerEdge: 1600SC, 1650, 1750, 2600, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI−X QLogic QLA2340−E−SP6 FC−AL, EMC N11, 47
2650, 2850, 4600, 6600, 6650; v2.4.21−32.EL30, 97, 98 FC−SW CLARiiON
AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
Samsung: SS370, SS3840
17 IBM xSeries: x235, x255, x346 (8840)12, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI−X QLogic QLA2340−E−SP6, 95 FC−AL, EMC N11, 47
x360, x365, x440 v2.4.21−32.EL30, 97, 98 FC−SW CLARiiON
AX150
18 Dell PowerEdge 1850; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI, QLogic QLA2340−E−SP6 FC−AL, EMC N11, 47
HPQ Proliant: DL380(G2)9, DL380(G3)9, v2.4.21−32.EL30, 97, 98 PCI−X FC−SW CLARiiON
DL380(G4)9, DL3809, DL580(G2)9, AX150
DL580(G3)9, ML370(G3)9, ML370(G4)9
19 IBM xSeries: x345 (8670), x445 (8870) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES PCI, QLogic QLA2340−E−SP6, 95 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98 PCI−X FC−SW CLARiiON
AX150
20 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E1, 13, 104, LP1050−E1, FC−AL, EMC N11, 47
2500, 255065, 4300, 4350, 4400, 6100, v2.4.21−32.EL30, 97, 98, 3, 104, LP982−E1, 104 FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450 v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
21 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E1, 13, 99, LP1050−E1, 3, FC−AL, EMC N11, 47
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.4.21−32.EL30, 97, 98, 99, LP982−E1, 99; FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, v2.4.21−32.EL30, 98; AX150
ML530(G3)9, ML5309, ML5709, ML7509 QLogic: QLA200−E−SP26, 96, 106 ,
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLA2340−E−SP6, 100, 106
v2.4.21−32.0.1.EL30, 98
22 NEC Express 5800: 120Rd−1, 140Hd, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI NEC N8190−120: (LP1050)1, 13, 23, 101 , FC−AL, EMC N11, 47
140Rc−4, 180Rd−4 v2.4.21−32.EL30, 97, 98, (LP1050)1, 13, 23, 102, 103 FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
23 Dell PowerEdge: 1800, 1850, 2800, 2850, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex LP1050Ex−E1, 2, 13, 54 ; FC−AL, EMC Y11, 47
6800, 6850; v2.4.21−32.EL30, 97, 98, Express QLogic QLE2360−E−SP2, 14, 15, 29 FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Digital Henge INNO: HR−4850, HR−6850;
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
Digital Henge Revo: JS1400, JS2400; v2.4.21−32.0.1.EL30, 98
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
24 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E1, 2, 13, 99 , LP1050−E1, FC−AL, EMC Y11, 47
v2.4.21−32.EL30, 97, 98, Express, 2, 3, 99; FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.4.21−32.EL30, 98; PCI−X AX150
NF520 QLogic QLA200−E−SP2, 26, 95, 96
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
25 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI Emulex: LP101−E1, 13, 99, LP1050−E1, 3, FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, Express, 99, LP982−E1, 99; FC−SW CLARiiON
v2.4.21−32.EL30, 98; PCI−X AX150
QLogic: QLA200−E−SP26, 106,
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES QLA2340−E−SP6, 100, 106
v2.4.21−32.0.1.EL30, 98
26 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Dell 2342M6, 95 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
27 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex LP101−E1, 13, 104 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
28 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex LP101−E1, 13, 99 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)9, v2.4.21−32.EL30, 98; AX150
9 9 9 9
DL360(G4) , DL560 , DL740 , DL760 (G2) ,
DL7609, ML570(G2)9 Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
29 Dell PowerEdge: 2600, 2650, 6800, 6850; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP101−E1, 2, 13, 99 , LP1050−E1, FC−AL, EMC Y11, 47
v2.4.21−32.EL30, 97, 98, 2, 3, 99; FC−SW CLARiiON
Digital Henge SH4500R4; v2.4.21−32.EL30, 98; AX150
IBM xSeries: x336 (8837)12, x346 (8840)12, QLogic QLA200−E−SP2, 26, 95, 96
x3850/x366 (8863)62, 63; Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS370, SS3840, ZSS150,
ZSS230

11/02/2006 291 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
30 Dell PowerEdge: 1600SC, 1650, 1750, 4600, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP1050−E1, 3, 104, LP982−E1, FC−AL, EMC N11, 47
6600, 6650 v2.4.21−32.EL30, 97, 98, 104 FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
31 HPQ Proliant: BL40p, DL360(G3)9, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X Emulex: LP1050−E1, 3, 99, LP982−E1, 99; FC−AL, EMC N11, 47
DL360(G4)9, DL5609, DL7409, DL760 (G2)9, v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
DL7609, ML570(G2)9 v2.4.21−32.EL30, 98; QLogic QLA2340−E−SP6, 100, 106 AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
32 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X HPQ Dual−port Fibre Channel Adapter FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, for HP Proliant BL25p/BL45p FC−SW CLARiiON
v2.4.21−32.EL30, 98; 381881−B2182, 96, 107 AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
33 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X NEC N8190−120: (LP1050)1, 13, 23, 101 , FC−AL, EMC N11, 47
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−32.EL30, 97, 98, (LP1050)1, 13, 23, 102, 103 FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
34 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X QLogic QLA200−E−SP26, 106 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
35 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X QLogic QLA200−E−SP26, 96, 106 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)9, DL5609, v2.4.21−32.EL30, 98; AX150
DL7409, DL760 (G2)9, DL7609, ML570(G2)9
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
36 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X QLogic QLA2340−E−SP6, 100 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, FC−SW CLARiiON
IBM xSeries: x255, x365, x440 v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
37 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, for HP Proliant BL25p/BL45p FC−SW CLARiiON
v2.4.21−32.EL30, 98; 381881−B2182, 96, 107 AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
38 IBM xSeries: x3800/x260 (8865)62, 63, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X64 Emulex: LP101−E1, 2, 13, 99 , LP1050−E1, FC−AL, EMC Y11, 47
x3950/x3950E/x460 (8872, 8874)62, 63 v2.4.21−32.EL30, 97, 98, 2, 3, 99; FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
QLogic QLA200−E−SP2, 26, 95, 96
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
39 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex LP101−E1, 13, 99 FC−AL, EMC N11, 47
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−32.EL30, 97, 98, PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.4.21−32.EL30, 98; AX150
ML370(G3)9, ML370(G4)9
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
40 HPQ Proliant DL3859 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex LP1050−E1, 3, 104 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, PCI−X FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
41 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex LP1050−E1, 3, 99 FC−AL, EMC N11, 47
DL380(G3)9, DL380(G4)9, DL3809, v2.4.21−32.EL30, 97, 98, PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.4.21−32.EL30, 98; AX150
ML370(G3)9, ML370(G4)9
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
42 HPQ Proliant: DL380(G2)9, DL380(G3)9, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex LP982−E1, 99; FC−AL, EMC N11, 47
DL380(G4)9, DL3809, DL580(G2)9, v2.4.21−32.EL30, 97, 98, PCI−X QLogic QLA2340−E−SP6, 100, 106 FC−SW CLARiiON
DL580(G3)9, ML370(G3)9, ML370(G4)9 v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
43 Samsung: ES470, ES570, SS140 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, Emulex: LP101−E1, 2, 13, 99 , LP1050−E1, FC−AL, EMC Y11, 47
v2.4.21−32.EL30, 97, 98, PCI−X 2, 3, 99; FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
QLogic QLA200−E−SP2, 26, 95, 96
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
44 HPQ Proliant: DL380(G4)9, ML370(G4)9 Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, QLogic QLA200−E−SP26, 106 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, PCI−X FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
45 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, QLogic QLA200−E−SP26, 96, 106 FC−AL, EMC N11, 47
DL380(G3)9, DL3809, DL3859, DL580(G2)9, v2.4.21−32.EL30, 97, 98, PCI−X FC−SW CLARiiON
DL580(G3)9, DL5859, ML370(G3)9 v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98

11/02/2006 292 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
46 IBM xSeries x445 (8870) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI, QLogic QLA2340−E−SP6, 100 FC−AL, EMC N11, 47
v2.4.21−32.EL30, 97, 98, PCI−X FC−SW CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
47 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E1, 13, 32, LP1050−E1, 3, FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.4.21−40.EL30, 31 32, LP982−E1, 32 FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL5809, ML350(G2)9, ML350(G3)9, ML3509,
ML370(G2)9, ML3709, ML530(G2)9,
ML530(G3)9, ML5309, ML5709, ML7509
48 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI NEC N8190−120 (LP1050)1, 13, 23, 32 FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150
49 Unisys: ES3120, ES3120L, ES3140, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLA2340−E−SP2, 6, 29 FC−AL, EMC Y
ES3140L v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150
50 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic: QLA200−E−SP26, 29, FC−AL, EMC Y
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.4.21−40.EL30, 31 QLA210−E−SP2, 26, 29, FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, QLA2340−E−SP6, 29, QLE220−E−SP2, AX150
ML530(G3)9, ML5309, ML5709, ML7509 83, 84, 85

51 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 32 ; FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 Express QLogic QLE2360−E−SP2, 14, 15, 29 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
52 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LPe111−E1, 2, 25, 32 , FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 Express LPe1150−E1, 2, 17, 32 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
53 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.4.21−40.EL30, 31 Express 27, 32 FC−SW CLARiiON
AX150
54 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLE2460−E−SP2, 18, 29 FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 Express FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
55 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E1, 2, 13, 32 , LP1050−E1, FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, 2, 3, 32, LP982−E1, 2, 32; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX150
AS2500; QLogic: QLA200−E−SP2, 26, 37,
QLA2340−E−SP2, 6, 29
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
56 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP101−E1, 13, 32, LP1050−E1, 3, FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, 32, LP982−E1, 32; FC−SW CLARiiON
PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)2, 8, 29,
AE369A/FC1243 (QLA2462)2, 8, 29;
QLogic: QLA200−E−SP26, 29,
QLA2340−E−SP6, 29, QLE220−E−SP2,
83, 84, 85

57 IBM xSeries: x3550 (7978), x3650 (7979) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP1050−E1, 2, 3, 32, FC−AL, EMC Y66
v2.4.21−40.EL30, 31 Express, LP1050Ex−E1, 2, 13, 32 ; FC−SW CLARiiON
PCI−X AX150
IBM: 24P0960 (QLA2340)2, 6, 16, 29 ,
24P8053 (QLA2342)2, 6, 29, 39M5894
(QLA2460)2, 18, 29, 39M5895
(QLA2462)2, 18, 29;
QLogic: QLA2340−E−SP2, 6, 29,
QLA2460−E−SP2, 18, 29,
QLE2360−E−SP2, 14, 29,
QLE2460−E−SP2, 18, 29

11/02/2006 293 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
58 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI Emulex: LP1050Ex−E1, 2, 13, 32 , FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, LPe111−E1, 2, 25, 32 , LPe1150−E1, 2, 17, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X 32; AX150
AS2500;
QLogic: QLE2360−E−SP2, 14, 15, 29 ,
IBM eServer 326m (Model 7969); QLE2460−E−SP2, 18, 29
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
59 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI QLogic QLA210−E−SP2, 26, 29 FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX150
AS2500;
HPQ Proliant ML350(G4)9;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
60 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Dell 2342M6, 29 FC−AL, EMC Y
Unisys ES3105 v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150
61 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Dell: LPe1105−M1, 2, 17, 32 , QME24622, FC−AL, EMC Y
v2.4.21−40.EL30, 31 29, 53 FC−SW CLARiiON
AX150
62 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex LP982−E1, 2, 32 FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)12, x346 (8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
63 Dell PowerEdge: 1800, 1850, 1950, 2600, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex: LP101−E1, 2, 13, 32 , LP1050−E1, FC−AL, EMC Y
2650, 2850, 6800, 6850; v2.4.21−40.EL30, 31 2, 3, 32; FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850; QLogic: QLA200−E−SP2, 26, 37,
QLA2340−E−SP2, 6, 29
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)12, x346 (8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
64 Dell PowerEdge: 1600SC, 1650, 1750, 4600, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Emulex: LP101−E1, 13, 32, LP1050−E1, 3, FC−AL, EMC Y
6600, 6650; v2.4.21−40.EL30, 31 32, LP982−E1, 32 FC−SW CLARiiON
AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9
65 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(416654−B21), (416655−B21), v2.4.21−40.EL30, 31 for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403621−B21)25, 28, 32 AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
66 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416654−B21), (416655−B21), v2.4.21−40.EL30, 31 HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403619−B21)24, 29 AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
67 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 8, 29, FC−AL, EMC Y
v2.4.21−40.EL30, 31 AE369A/FC1243 (QLA2462)2, 8, 29 FC−SW CLARiiON
AX150
68 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y
v2.4.21−40.EL30, 31 for HP Proliant BL25p/BL45p FC−SW CLARiiON
381881−B2129, 82, Emulex−based AX150
BL25/30/35/45p Fibre Channel
Mezzanine HBA − 394588−B211, 32, 55,
56

69 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 32 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−40.EL30, 31 FC−SW CLARiiON
140Rd−4 AX150
70 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 23, 27, 32 FC−AL, EMC Y
v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150

11/02/2006 294 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
71 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic QLA210−E−SP2, 26, 29 FC−AL, EMC Y
2850, 4600, 6600, 6650, 6800, 6850; v2.4.21−40.EL30, 31 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
72 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic QLE220−E−SP2, 83, 84, 85 FC−AL, EMC Y
v2.4.21−40.EL30, 31 FC−SW CLARiiON
Digital Henge SH4500R4; AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
73 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X QLogic: QLA200−E−SP26, 29, FC−AL, EMC Y
v2.4.21−40.EL30, 31 QLA2340−E−SP6, 29 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)9, AX150
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9
74 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X57 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y
v2.4.21−40.EL30, 31 Channel Mezzanine HBA − FC−SW CLARiiON
394757−B211, 32, 55, 56 AX150
75 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X57 HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y
v2.4.21−40.EL30, 31 Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394588−B211, 32, 55, 56 AX150
76 IBM xSeries: x3800/x260 (8865)62, 63, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X64 QLogic: QLA210−E−SP2, 26, 29, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)62, 63 v2.4.21−40.EL30, 31 QLE220−E−SP2, 83, 84, 85 FC−SW CLARiiON
AX150
77 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X70 Emulex: LP101−E1, 2, 13, 32 , LP1050−E1, FC−AL, EMC Y
v2.4.21−40.EL30, 31 2, 3, 32, LP982−E1, 2, 32; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP2, 26, 37,
QLA210−E−SP2, 26, 29,
QLA2340−E−SP2, 6, 29, QLE220−E−SP2,
83, 84, 85

78 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 32 , QME24622, FC−AL, EMC Y
v2.4.21−40.EL30, 31 Express, 29, 53 FC−SW CLARiiON
PCI−X AX150
79 HPQ Proliant: DL380(G2)9, DL380(G3)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex LP982−E1, 32 FC−AL, EMC Y
DL380(G4)9, DL3809, DL580(G2)9, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL580(G3)9, ML370(G3)9, ML370(G4)9 AX150
80 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E1, 2, 13, 32 , LP1050−E1, FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−40.EL30, 31 PCI−X 2, 3, 32, LP982−E1, 2, 32; FC−SW CLARiiON
AX150
QLogic QLA200−E−SP2, 26, 37
81 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, Emulex: LP101−E1, 13, 32, LP1050−E1, 3, FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−40.EL30, 31 PCI−X 32; FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9 QLogic QLA200−E−SP26, 29
82 HPQ Proliant: DL380(G4)9, ML370(G4)9 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 8, 29, FC−AL, EMC Y
v2.4.21−40.EL30, 31 PCI−X AE369A/FC1243 (QLA2462)2, 8, 29 FC−SW CLARiiON
AX150
83 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA210−E−SP2, 26, 29 FC−AL, EMC Y
HPQ Proliant: DL1459, DL380(G2)9, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL380(G3)9, DL380(G4)9, DL3809, DL3859, AX150
DL580(G2)9, DL580(G3)9, DL5859,
ML370(G3)9, ML370(G4)9;
Samsung: ES470, ES570, SS140
84 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 29 FC−AL, EMC Y
Fujitsu Siemens Primergy RX800 S2; v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 AX150
85 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 37 FC−AL, EMC Y
Samsung ES470 v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
AX150
86 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP6, 29 FC−AL, EMC Y
HPQ Proliant: DL380(G2)9, DL380(G3)9, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL380(G4)9, DL3809, DL580(G2)9, AX150
DL580(G3)9, ML370(G3)9, ML370(G4)9

11/02/2006 295 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
87 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI, QLogic QLE220−E−SP2, 83, 84, 85 FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−40.EL30, 31 PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9;
Samsung: ES470, ES570, SS140
88 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.4.21−47.EL30, 31 38, LP982−E1, 38 FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL5809, ML350(G2)9, ML350(G3)9, ML3509,
ML370(G2)9, ML3709, ML530(G2)9,
ML530(G3)9, ML5309, ML5709, ML7509
89 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI NEC N8190−120 (LP1050)1, 13, 23, 38 FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.4.21−47.EL30, 31 FC−SW CLARiiON
AX150
90 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic: QLA200−E−SP26, 44, FC−AL, EMC Y
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.4.21−47.EL30, 31 QLA210−E−SP2, 26, 44, FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, QLA2340−E−SP6, 44, QLE220−E−SP2, AX150
ML530(G3)9, ML5309, ML5709, ML7509 84, 85

91 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 38 ; FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 Express QLogic QLE2360−E−SP2, 14, 15, 44 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
92 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LPe111−E1, 2, 25, 38 , FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 Express LPe1150−E1, 2, 17, 38 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
93 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.4.21−47.EL30, 31 Express 27, 38 FC−SW CLARiiON
AX150
94 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(403434−B21), (407234−B21), v2.4.21−47.EL30, 31 Express for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)25, 28, 38 AX150
95 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(403434−B21), (407234−B21), v2.4.21−47.EL30, 31 Express HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403619−B21)24, 44 AX150
96 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic QLE2460−E−SP2, 18, 44 FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 Express FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
97 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E1, 2, 13, 38 , LP1050−E1, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 2, 3, 38, LP982−E1, 2, 38; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX150
AS2500; QLogic: QLA200−E−SP2, 26, 44,
QLA2340−E−SP2, 6, 44
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
98 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 38, LP982−E1, 38; FC−SW CLARiiON
PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)2, 8, 44,
AE369A/FC1243 (QLA2462)2, 8, 44;
QLogic: QLA200−E−SP26, 44,
QLA2340−E−SP6, 44, QLE220−E−SP2,
84, 85

99 IBM xSeries: x3550 (7978), x3650 (7979), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP1050−E1, 2, 3, 38, FC−AL, EMC Y66
x3755 (8877) v2.4.21−47.EL30, 31 Express, LP1050Ex−E1, 2, 13, 38 ; FC−SW CLARiiON
PCI−X AX150
IBM: 24P0960 (QLA2340)2, 6, 16, 44 ,
24P8053 (QLA2342)2, 6, 44, 39M5894
(QLA2460)2, 18, 44, 39M5895
(QLA2462)2, 18, 44;
QLogic: QLA2340−E−SP2, 6, 44,
QLA2460−E−SP2, 18, 44,
QLE2360−E−SP2, 14, 44,
QLE2460−E−SP2, 18, 44

11/02/2006 296 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
100 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI Emulex: LP1050Ex−E1, 2, 13, 38 , FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, LPe111−E1, 2, 25, 38 , LPe1150−E1, 2, 17, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X 38; AX150
AS2500;
QLogic: QLE2360−E−SP2, 14, 15, 44 ,
IBM eServer 326m (Model 7969); QLE2460−E−SP2, 18, 44
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
101 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI NEC: N8190−120 (LP1050)3, 23, 38, 79 , FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.4.21−47.EL30, 31 Express, N8190−127 (LPe1150)17, 23, 38, 79 FC−SW CLARiiON
PCI−X AX150
102 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI QLogic QLA210−E−SP2, 26, 44 FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, PCI−X AX150
AS2500;
HPQ Proliant ML350(G4)9;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
103 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Dell 2342M6, 44 FC−AL, EMC Y
Unisys ES3105 v2.4.21−47.EL30, 31 FC−SW CLARiiON
AX150
104 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Dell: LPe1105−M1, 2, 17, 38 , QME24622, FC−AL, EMC Y
v2.4.21−47.EL30, 31 44, 53 FC−SW CLARiiON
AX150
105 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Emulex LP982−E1, 2, 38 FC−AL, EMC Y
2850, 6800, 6850; v2.4.21−47.EL30, 31 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)12, x346 (8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
106 Dell PowerEdge: 1800, 1850, 1950, 2600, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Emulex: LP101−E1, 2, 13, 38 , LP1050−E1, FC−AL, EMC Y
2650, 2850, 6800, 6850; v2.4.21−47.EL30, 31 2, 3, 38; FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850; QLogic: QLA200−E−SP2, 26, 44,
QLA2340−E−SP2, 6, 44
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)12, x346 (8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
107 Dell PowerEdge: 1600SC, 1650, 1750, 4600, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
6600, 6650; v2.4.21−47.EL30, 31 38, LP982−E1, 38 FC−SW CLARiiON
AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9
108 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(416654−B21), (416655−B21), v2.4.21−47.EL30, 31 for HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403621−B21)25, 28, 38 AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
109 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416654−B21), (416655−B21), v2.4.21−47.EL30, 31 HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); (403619−B21)24, 44 AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
110 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 8, 44, FC−AL, EMC Y
v2.4.21−47.EL30, 31 AE369A/FC1243 (QLA2462)2, 8, 44 FC−SW CLARiiON
AX150
111 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y
v2.4.21−47.EL30, 31 for HP Proliant BL25p/BL45p FC−SW CLARiiON
381881−B2144, 82, Emulex−based AX150
BL25/30/35/45p Fibre Channel
Mezzanine HBA − 394588−B211, 38, 55,
56

112 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 38 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.4.21−47.EL30, 31 FC−SW CLARiiON
140Rd−4 AX150
113 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 23, 27, 38 FC−AL, EMC Y
v2.4.21−47.EL30, 31 FC−SW CLARiiON
AX150

11/02/2006 297 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
114 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X QLogic QLA210−E−SP2, 26, 44 FC−AL, EMC Y
2850, 4600, 6600, 6650, 6800, 6850; v2.4.21−47.EL30, 31 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
115 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X QLogic QLE220−E−SP2, 84, 85 FC−AL, EMC Y
v2.4.21−47.EL30, 31 FC−SW CLARiiON
Digital Henge SH4500R4; AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
116 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X QLogic: QLA200−E−SP26, 44, FC−AL, EMC Y
v2.4.21−47.EL30, 31 QLA2340−E−SP6, 44 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)9, AX150
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9
117 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y
v2.4.21−47.EL30, 31 for HP Proliant BL25p/BL45p FC−SW CLARiiON
381881−B2144, 82 AX150
118 HPQ Proliant BL20p: (G3), (G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X57 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y
v2.4.21−47.EL30, 31 Channel Mezzanine HBA − FC−SW CLARiiON
394757−B211, 38, 55, 56 AX150
119 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X57 HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y
v2.4.21−47.EL30, 31 Fibre Channel Mezzanine HBA − FC−SW CLARiiON
394588−B211, 38, 55, 56 AX150
120 IBM xSeries: x3800/x260 (8865)62, 63, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X64 QLogic: QLA210−E−SP2, 26, 44, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)62, 63 v2.4.21−47.EL30, 31 QLE220−E−SP2, 84, 85 FC−SW CLARiiON
AX150
121 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X70 Emulex: LP101−E1, 2, 13, 38 , LP1050−E1, FC−AL, EMC Y
v2.4.21−47.EL30, 31 2, 3, 38, LP982−E1, 2, 38; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP2, 26, 44,
QLA210−E−SP2, 26, 44,
QLA2340−E−SP2, 6, 44, QLE220−E−SP2,
84, 85

122 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 38 , QME24622, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 44, 53 FC−SW CLARiiON
PCI−X AX150
123 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, 38, LP982−E1, 38, LPe111−E1, 2, 25, 38 , FC−SW CLARiiON
PCI−X LPe1150−E1, 2, 17, 38 ; AX150
HPQ: A8002A/FC2142SR (LPe1150)1, 2,
27, 38, AE311A/FC1142SR (QLE2460)2,
18, 44, AE312A/FC1242SR (QLE2462)2,
18, 44;

QLogic: QLA200−E−SP26, 44,


QLA210−E−SP2, 26, 44,
QLA2340−E−SP6, 44, QLE220−E−SP2,
84, 85

124 HPQ Proliant DL380(G5) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 8, 44, FC−AL, EMC Y
v2.4.21−47.EL30, 31 Express, AE369A/FC1243 (QLA2462)2, 8, 44 FC−SW CLARiiON
PCI−X AX150
125 HPQ Proliant: DL380(G2)9, DL380(G3)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex LP982−E1, 38; FC−AL, EMC Y
DL380(G4)9, DL3809, DL580(G2)9, v2.4.21−47.EL30, 31 PCI−X QLogic QLA2340−E−SP6, 44 FC−SW CLARiiON
DL580(G3)9, ML370(G3)9, ML370(G4)9 AX150
126 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex: LP101−E1, 2, 13, 38 , LP1050−E1, FC−AL, EMC Y
Samsung: ES470, ES570, SS140 v2.4.21−47.EL30, 31 PCI−X 2, 3, 38, LP982−E1, 2, 38; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP2, 26, 44,
QLA2340−E−SP2, 6, 44
127 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, Emulex: LP101−E1, 13, 38, LP1050−E1, 3, FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−47.EL30, 31 PCI−X 38; FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9 QLogic QLA200−E−SP26, 44

11/02/2006 298 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
128 HPQ Proliant: DL380(G4)9, ML370(G4)9 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 8, 44, FC−AL, EMC Y
v2.4.21−47.EL30, 31 PCI−X AE369A/FC1243 (QLA2462)2, 8, 44 FC−SW CLARiiON
AX150
129 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, QLogic QLA210−E−SP2, 26, 44 FC−AL, EMC Y
HPQ Proliant: DL1459, DL380(G2)9, v2.4.21−47.EL30, 31 PCI−X FC−SW CLARiiON
DL380(G3)9, DL380(G4)9, DL3809, DL3859, AX150
DL580(G2)9, DL580(G3)9, DL5859,
ML370(G3)9, ML370(G4)9;
Samsung: ES470, ES570, SS140
130 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI, QLogic QLE220−E−SP2, 84, 85 FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−47.EL30, 31 PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9;
Samsung: ES470, ES570, SS140
131 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E1, 13, 54, LP1050−E1, 3, FC−AL, EMC N11, 47
2500, 255065, 4300, 4350, 4400, 6100, v2.4.21−37.EL, U6+ AS/ES 54, LP982−E1, 54 FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; v2.4.21−37.0.1.EL AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL5809, ML350(G2)9, ML350(G3)9, ML3509,
ML370(G2)9, ML3709, ML530(G2)9,
ML530(G3)9, ML5309, ML5709, ML7509
132 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI NEC N8190−120 (LP1050)1, 13, 23, 80 FC−AL, EMC N11, 47
140Hd, 140Rc−4, 180Rd−4 v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
133 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI QLogic: QLA200−E−SP26, 29, FC−AL, EMC N11, 47
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.4.21−37.EL, U6+ AS/ES QLA210−E−SP2, 26, 29, FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, v2.4.21−37.0.1.EL QLA2340−E−SP6, 29 AX150
ML530(G3)9, ML5309, ML5709, ML7509
134 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 54 ; FC−AL, EMC Y11, 47
2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES Express QLogic QLE2360−E−SP2, 14, 15, 29 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
135 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LPe111−E1, 2, 25, 54 , FC−AL, EMC Y11, 47
2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES Express LPe1150−E1, 2, 17, 54 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
136 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y11, 47
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.4.21−37.EL, U6+ AS/ES Express 27, 54 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
137 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI QLogic QLE2460−E−SP2, 18, 29 FC−AL, EMC Y11, 47
2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES Express FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
138 Dell PowerEdge: 2900, 2950 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E1, 2, 13, 54 , LP1050−E1, FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES Express, 2, 3, 54, LP982−E1, 2, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL PCI−X AX150
QLogic: QLA200−E−SP2, 26, 37,
QLA210−E−SP2, 26, 29,
QLA2340−E−SP2, 6, 29
139 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP101−E1, 13, 54, LP1050−E1, 3, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES Express, 54, LP982−E1, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)2, 8, 29,
AE369A/FC1243 (QLA2462)2, 8, 29;
QLogic: QLA200−E−SP26, 29,
QLA210−E−SP2, 26, 29,
QLA2340−E−SP6, 29
140 Dell PowerEdge: 2900, 2950; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI Emulex: LP1050Ex−E1, 2, 13, 54 , FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES Express, LPe111−E1, 2, 25, 54 , LPe1150−E1, 2, 17, FC−SW CLARiiON
IBM eServer 326m (Model 7969) v2.4.21−37.0.1.EL PCI−X 54; AX150
QLogic: QLE2360−E−SP2, 14, 15, 29 ,
QLE2460−E−SP2, 18, 29

11/02/2006 299 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
141 Dell PowerEdge 1855; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Dell 2342M6, 29 FC−AL, EMC N11, 47
Unisys ES3105 v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
142 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Dell: LPe1105−M1, 2, 17, 54 , QME24622, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES 29, 53 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
143 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex LP982−E1, 2, 54 FC−AL, EMC Y11, 47
2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
144 Dell PowerEdge: 1800, 1850, 1950, 2600, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex: LP101−E1, 2, 13, 54 , LP1050−E1, FC−AL, EMC Y11, 47
2650, 2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES 2, 3, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850; QLogic: QLA200−E−SP2, 26, 37,
QLA2340−E−SP2, 6, 29
Digital Henge SH4500R4;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
145 Dell PowerEdge: 1600SC, 1650, 1750, 4600, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex: LP101−E1, 13, 54, LP1050−E1, 3, FC−AL, EMC N11, 47
6600, 6650; v2.4.21−37.EL, U6+ AS/ES 54, LP982−E1, 54 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
HPQ Proliant: DL360(G3)9, DL360(G4)9,
DL5609, DL7409, DL760 (G2)9, DL7609,
ML570(G2)9
146 HPQ Proliant BL40p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Emulex: LP101−E1, 13, 54, LP1050−E1, 3, FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES 54, LP982−E1, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
QLogic: QLA200−E−SP26, 29,
QLA2340−E−SP6, 29
147 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 8, 29, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES AE369A/FC1243 (QLA2462)2, 8, 29 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
148 HPQ Proliant BL45p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X HPQ: Dual−port Fibre Channel Adapter FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES for HP Proliant BL25p/BL45p FC−SW CLARiiON
v2.4.21−37.0.1.EL 381881−B2129, 82, Emulex−based AX150
BL25/30/35/45p Fibre Channel
Mezzanine HBA − 394588−B211, 54, 55,
56

149 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 80 FC−AL, EMC N11, 47
120Rf−1, 120Rg−2, 120Rh−2 v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
150 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X NEC: N8190−120 (LP1050)1, 13, 23, 54 , FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES N8190−127 (LPe1150)1, 23, 27, 54 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
151 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic QLA210−E−SP2, 26, 29 FC−AL, EMC Y11, 47
2850, 6800, 6850; v2.4.21−37.EL, U6+ AS/ES FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
HPQ Proliant BL40p;
IBM xSeries: x336 (8837)12, x346 (8840)12,
x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, ZSS150, ZSS230
152 Dell PowerEdge: 4600, 6600, 6650; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X QLogic: QLA200−E−SP26, 29, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES QLA210−E−SP2, 26, 29, FC−SW CLARiiON
HPQ Proliant: DL360(G3)9, DL360(G4)9, v2.4.21−37.0.1.EL QLA2340−E−SP6, 29 AX150
DL5609, DL7409, DL760 (G2)9, DL7609,
ML570(G2)9
153 HPQ Proliant BL20p (G3) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Emulex−based BL20p (G3) Fibre FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES Channel Mezzanine HBA − FC−SW CLARiiON
v2.4.21−37.0.1.EL 394757−B211, 54, 55, 56 AX150
154 HPQ Proliant BL30p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Emulex−based BL25/30/35/45p FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES Fibre Channel Mezzanine HBA − FC−SW CLARiiON
v2.4.21−37.0.1.EL 394588−B211, 54, 55, 56 AX150

11/02/2006 300 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
155 IBM xSeries: x3800/x260 (8865)62, 63, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X64 Emulex: LP101−E1, 2, 13, 54 , LP1050−E1, FC−AL, EMC Y11, 47
x3950/x3950E/x460 (8872, 8874)62, 63 v2.4.21−37.EL, U6+ AS/ES 2, 3, 54, LP982−E1, 2, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
QLogic: QLA200−E−SP2, 26, 37,
QLA210−E−SP2, 26, 29,
QLA2340−E−SP2, 6, 29
156 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X70 Emulex: LP101−E1, 2, 13, 54 , LP1050−E1, FC−AL, EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES 2, 3, 54, LP982−E1, 2, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
QLogic: QLA200−E−SP2, 26, 37,
QLA210−E−SP2, 26, 29,
QLA2340−E−SP2, 6, 29
157 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 54 , QME24622, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES Express, 29, 53 FC−SW CLARiiON
v2.4.21−37.0.1.EL PCI−X AX150
158 HPQ Proliant: DL380(G2)9, DL380(G3)9, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex LP982−E1, 54; FC−AL, EMC N11, 47
DL380(G4)9, DL3809, DL580(G2)9, v2.4.21−37.EL, U6+ AS/ES PCI−X QLogic QLA2340−E−SP6, 29 FC−SW CLARiiON
DL580(G3)9, ML370(G3)9, ML370(G4)9 v2.4.21−37.0.1.EL AX150
159 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex: LP101−E1, 2, 13, 54 , LP1050−E1, FC−AL, EMC Y11, 47
Samsung: ES470, ES570, SS140 v2.4.21−37.EL, U6+ AS/ES PCI−X 2, 3, 54, LP982−E1, 2, 54; FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
QLogic: QLA200−E−SP2, 26, 37,
QLA210−E−SP2, 26, 29
160 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, Emulex: LP101−E1, 13, 54, LP1050−E1, 3, FC−AL, EMC N11, 47
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.4.21−37.EL, U6+ AS/ES PCI−X 54; FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.4.21−37.0.1.EL AX150
ML370(G3)9, ML370(G4)9 QLogic: QLA200−E−SP26, 29,
QLA210−E−SP2, 26, 29
161 HPQ Proliant: DL380(G4)9, ML370(G4)9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 8, 29, FC−AL, EMC N11, 47
v2.4.21−37.EL, U6+ AS/ES PCI−X AE369A/FC1243 (QLA2462)2, 8, 29 FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
162 Dell PowerEdge 2800; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 29 FC−AL, EMC Y11, 47
Fujitsu Siemens Primergy RX800 S2; v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
Samsung: ES570, SS140 v2.4.21−37.0.1.EL AX150
163 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 37 FC−AL, EMC Y11, 47
Samsung ES470 v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
164 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP6, 29 FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES PCI−X FC−SW CLARiiON
v2.4.21−37.0.1.EL AX150
165 HPQ Proliant BL25p Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X57 HPQ Dual−port Fibre Channel Adapter FC−AL, EMC Y
v2.4.21−37.EL, U6+ AS/ES for HP Proliant BL25p/BL45p FC−SW CLARiiON
v2.4.21−37.0.1.EL, U7 AS/ES 381881−B2129, 82 AX150
v2.4.21−40.EL30, 31
166 Dell PowerEdge 1950 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP2, 45, 50 FC−AL, EMC Y
v2.4.21−40.EL30, 31, U8 AS/ES Express FC−SW CLARiiON
v2.4.21−47.EL30, 31 AX150
167 Dell PowerEdge: 1850, 1900, 2850, 2900, Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP2, 45, 50 FC−AL, EMC Y
2950, 6800, 6850, 6950; v2.4.21−40.EL30, 31, U8 AS/ES Express, FC−SW CLARiiON
v2.4.21−47.EL30, 31 PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
168 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP2, 45, 50 FC−AL, EMC Y
v2.4.21−40.EL30, 31, U8 AS/ES Express, FC−SW CLARiiON
v2.4.21−47.EL30, 31 PCI−X AX150
169 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL81 Express for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)4, 25, 28, 38 AX150
170 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y33
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL81 Express for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)4, 28, 34 AX150
171 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL81 Express HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403619−B21)5, 24, 44 AX150
172 HPQ Proliant BL465c: (403433−B21), Red Hat RHEL [32−Bit] 4.0 AS/ES PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
(403434−B21), (407234−B21), v2.6.9−5.0.5.EL81 Express for HP c−Class Bladesystem FC−SW CLARiiON
(407235−B21) (403621−B21)4, 28, 34, QLogic QMH2462 AX150
4Gb FC HBA for HP c−Class
Bladesystem (403619−B21)5, 24
173 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex LP101−E1, 2, 13, 108 ; FC−AL, EMC N11, 47
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−11.EL81 QLogic QLA200−E−SP2, 26, 91 FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL380(G2)9, DL380(G3)9, DL3809,
DL580(G2)9, DL5809, ML350(G2)9,
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
174 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex: LP1050−E1, 2, 3, 108 , LP982−E1, FC−AL, EMC N11, 47
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−11.EL81 2, 108; FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450 AX150
QLogic QLA2340−E−SP2, 6, 91
175 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex: LP1050−E1, 3, 108, LP982−E1, FC−AL, EMC N11, 47
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.6.9−11.EL81 108 FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, AX150
ML530(G3)9, ML5309, ML5709, ML7509

11/02/2006 301 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
176 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI QLogic QLA2340−E−SP6, 91 FC−AL, EMC N11, 47
DL380(G2)9, DL380(G3)9, DL3809, v2.6.9−11.EL81 FC−SW CLARiiON
DL580(G2)9, DL5809, ML350(G2)9, AX150
9 9 9
ML350(G3) , ML350 , ML370(G2) , ML370 ,9
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
177 Dell PowerEdge: 1800, 1850, 2800, 2850, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 108 ; FC−AL, EMC Y11, 47
6800, 6850; v2.6.9−11.EL81 Express QLogic QLE2360−E−SP2, 14, 15, 91 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
178 Dell PowerEdge 2850 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI QLogic QLA200−E−SP2, 21, 26, 91 FC−AL, EMC Y11, 47
v2.6.9−11.EL81 Express FC−SW CLARiiON
AX150
179 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI Emulex: LP101−E1, 2, 13, 108 , FC−AL, EMC N11, 47
v2.6.9−11.EL81 Express, LP1050−E1, 3, 108, LP982−E1, 108; FC−SW CLARiiON
PCI−X AX150
QLogic: QLA200−E−SP2, 26, 91,
QLA2340−E−SP6, 91
180 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Dell 2342M6, 91 FC−AL, EMC N11, 47
v2.6.9−11.EL81 FC−SW CLARiiON
AX150
181 Dell PowerEdge: 1600SC, 1650, 1750; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP101−E1, 2, 13, 108 FC−AL, EMC N11, 47
v2.6.9−11.EL81 FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)9, AX150
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9
182 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP101−E1, 2, 13, 108 FC−AL, EMC Y11, 47
v2.6.9−11.EL81 FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12, x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230
183 Fujitsu Siemens Primergy: RX200 S2, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex LP101−E1, 2, 72, 108 FC−AL, EMC N11, 47
RX300, RX300 S2, TX200 S2, TX300, v2.6.9−11.EL81 FC−SW CLARiiON
TX300 S2 AX150
184 Dell PowerEdge: 6600, 6650 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP101−E1, 2, 13, 111 , LP101−E1, FC−AL, EMC Y11, 47
v2.6.9−11.EL81 13, 111, LP1050−E1, 2, 3, 110 , LP1050−E1, FC−SW CLARiiON
3, 110, LP982−E1, 2, 110, LP982−E1, 110 AX150
185 Dell PowerEdge: 1600SC, 1650, 1750 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP1050−E1, 2, 3, 108 , LP982−E1, FC−AL, EMC N11, 47
v2.6.9−11.EL81 2, 108; FC−SW CLARiiON
AX150
QLogic QLA2340−E−SP2, 6, 91
186 Dell PowerEdge: 6800, 6850; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP1050−E1, 2, 3, 108 , LP982−E1, FC−AL, EMC Y11, 47
v2.6.9−11.EL81 2, 108; FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; AX150
QLogic QLA2340−E−SP2, 6, 91
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12, x3850/x366 (8863)62, 63;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z
187 HPQ Proliant: BL40p, DL360(G3)9, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X Emulex: LP1050−E1, 3, 108, LP982−E1, FC−AL, EMC N11, 47
DL360(G4)9, DL5609, DL760 (G2)9, DL7609, v2.6.9−11.EL81 108 FC−SW CLARiiON
ML570(G2)9 AX150
188 Dell PowerEdge: 1600SC, 1650, 1750, 6600, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic QLA200−E−SP2, 26, 91 FC−AL, EMC N11, 47
6650; v2.6.9−11.EL81 FC−SW CLARiiON
AX150
Fujitsu Siemens Primergy: RX200 S2,
RX300, RX300 S2, TX200 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9

11/02/2006 302 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
189 Dell PowerEdge: 6600, 6650; Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic QLA2340−E−SP6, 91 FC−AL, EMC N11, 47
v2.6.9−11.EL81 FC−SW CLARiiON
Fujitsu Siemens Primergy: RX200 S2, AX150
RX300, RX300 S2, TX200 S2, TX300,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9
190 Dell PowerEdge: 6600, 6650 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X QLogic: QLA200−E−SP26, FC−AL, EMC N11, 47
v2.6.9−11.EL81 QLA2340−E−SP6 FC−SW CLARiiON
AX150
191 IBM xSeries: x3800/x260 (8865)62, 63, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X64 Emulex: LP101−E1, 2, 13, 108 , FC−AL, EMC Y11, 47
x3950/x3950E/x460 (8872, 8874)62, 63 v2.6.9−11.EL81 LP1050−E1, 2, 3, 108 , LP982−E1, 2, 108; FC−SW CLARiiON
AX150
QLogic QLA2340−E−SP2, 6, 91
192 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI−X70 Emulex: LP101−E1, 2, 13, 108 , FC−AL, EMC Y11, 47
v2.6.9−11.EL81 LP1050−E1, 2, 3, 108 , LP982−E1, 2, 108; FC−SW CLARiiON
AX150
QLogic QLA2340−E−SP2, 6, 91
193 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, Emulex LP101−E1, 2, 13, 108 FC−AL, EMC Y11, 47
2800, 2850; v2.6.9−11.EL81 PCI−X FC−SW CLARiiON
AX150
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
194 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, Emulex: LP101−E1, 2, 13, 108 , FC−AL, EMC N11, 47
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−11.EL81 PCI−X LP1050−E1, 3, 108, LP982−E1, 108; FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, AX150
ML370(G3)9, ML370(G4)9 QLogic QLA200−E−SP2, 26, 91
195 Dell PowerEdge: 1800, 1850, 2600, 2650, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, Emulex: LP1050−E1, 2, 3, 108 , LP982−E1, FC−AL, EMC Y11, 47
2800, 2850; v2.6.9−11.EL81 PCI−X 2, 108; FC−SW CLARiiON
AX150
IBM eServer: 325 (Model 8835), 326 (Model QLogic QLA2340−E−SP2, 6, 91
8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
196 IBM eServer: 325 (Model 8835), 326 (Model Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, IBM 24P0960 (QLA2340)2, 6, 16, 91 FC−AL, EMC Y11, 47
8848) v2.6.9−11.EL81 PCI−X FC−SW CLARiiON
AX150
197 Dell PowerEdge 2850 Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, QLogic QLA200−E−SP2, 21, 26, 91 FC−AL, EMC Y11, 47
v2.6.9−11.EL81 PCI−X FC−SW CLARiiON
AX150
198 HPQ Proliant: DL1459, DL380(G4)9, DL3859, Red Hat RHEL [32−Bit] 4.0 U1 AS/ES PCI, QLogic QLA2340−E−SP6, 91 FC−AL, EMC N11, 47
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−11.EL81 PCI−X FC−SW CLARiiON
ML370(G3)9, ML370(G4)9 AX150
199 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP101−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−22.EL, U2+ AS/ES QLogic: QLA200−E−SP2, 7, 26, FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; v2.6.9−22.0.1.EL, U2+ AS/ES QLA210−E−SP2, 7, 26 AX150
v2.6.9−22.0.2.EL
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL380(G2)9, DL380(G3)9, DL3809,
DL580(G2)9, DL5809, ML350(G2)9,
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
200 Fujitsu Siemens Primergy BX630: (2−way), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050−E1, 2, 51, 72 ; FC−AL, EMC Y
(4−way) v2.6.9−22.EL, U2+ AS/ES Fujitsu Siemens BX600−FC22Q2, 6, 49 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
201 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 2, 3, 51, LP982−E1, FC−AL, EMC Y10, 11
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−22.EL, U2+ AS/ES 2, 51; FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450 v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL QLogic QLA2340−E−SP2, 6, 7
202 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 3, 51, LP982−E1, 51 FC−AL, EMC Y10, 11
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
ML530(G3)9, ML5309, ML5709, ML7509 v2.6.9−22.0.2.EL
203 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI NEC N8190−120 (LP1050)1, 13, 23, 51 FC−AL, EMC Y10, 11
140Hd, 140Rc−4, 180Rd−4 v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
204 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI QLogic QLA2340−E−SP6, 7 FC−AL, EMC Y10, 11
DL380(G2)9, DL380(G3)9, DL3809, v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
DL580(G2)9, DL5809, ML350(G2)9, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
ML350(G3)9, ML3509, ML370(G2)9, ML3709, v2.6.9−22.0.2.EL
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
205 Unisys ES7000/460 [64−Bit] Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Unisys: FCH7440131−PCX (LP1150)1, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES 51, 71, FCH7440231−PCX (LP11002)1, 51, FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES 71, FCH752313−PCX (LP1050)1, 13, 51 AX150
v2.6.9−22.0.2.EL
206 Dell PowerEdge: 1800, 2800, 2850, 6800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP101−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
6850; v2.6.9−22.EL, U2+ AS/ES Express QLogic: QLA200−E−SP2, 7, 26, FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES QLA210−E−SP2, 7, 26 AX150
Digital Henge Revo: JS1400, JS2400 v2.6.9−22.0.2.EL
207 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES Express QLogic QLE2360−E−SP2, 7, 14, 15 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge Revo: JS1400, JS2400; v2.6.9−22.0.2.EL
IBM xSeries x336 (8837)12;
Lenovo SureServer: R650, T650;
Samsung ZSS150

11/02/2006 303 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
208 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LPe111−E1, 2, 25, 51 FC−AL, EMC Y10, 11
2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES Express FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge Revo: JS1400, JS2400; v2.6.9−22.0.2.EL
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
Lenovo SureServer: R650, T650;
Samsung ZSS150
209 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LPe1150−E1, 2, 17, 51 FC−AL, EMC Y10, 11
2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES Express FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
HPQ Proliant: DL360(G4)9, DL380(G4)9, v2.6.9−22.0.2.EL
DL580(G3)9, ML350(G4)9, ML370(G4)9
210 Digital Henge Revo: JS1400, JS2400; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LPe1150−E1, 2, 17, 60 FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express FC−SW CLARiiON
Lenovo SureServer: R650, T650; v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
Samsung ZSS150
211 Dell PowerEdge: 1800, 2800, 2850 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 2, 3, 51, LP982−E1, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express 2, 51; FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL QLogic QLA2340−E−SP2, 6, 7
212 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y10, 11
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.6.9−22.EL, U2+ AS/ES Express 27, 51 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
213 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI QLogic QLE2460−E−SP2, 7, 18 FC−AL, EMC Y10, 11
2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES Express FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge Revo: JS1400, JS2400; v2.6.9−22.0.2.EL
Lenovo SureServer: R650, T650;
Samsung ZSS150
214 Dell PowerEdge: 2900, 2950, 6800, 6850; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP101−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express, QLogic: QLA200−E−SP2, 7, 26, FC−SW CLARiiON
HPQ Proliant ML350(G4)9 v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X QLA210−E−SP2, 7, 26 AX150
v2.6.9−22.0.2.EL
215 Dell PowerEdge: 2900, 2950, 6800, 6850 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 2, 3, 51, LP982−E1, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express, 2, 51; FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X AX150
v2.6.9−22.0.2.EL QLogic QLA2340−E−SP2, 6, 7
216 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 3, 51, LP982−E1, 51; FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express, FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 7, 8, AX150
v2.6.9−22.0.2.EL AE369A/FC1243 (QLA2462)2, 7, 8;
QLogic QLA2340−E−SP6, 7
217 Dell PowerEdge: 2900, 2950; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E1, 2, 13, 51 , FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express, LPe111−E1, 2, 25, 51 , LPe1150−E1, 2, 17, FC−SW CLARiiON
IBM eServer 326m (Model 7969) v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X 51; AX150
v2.6.9−22.0.2.EL
QLogic: QLE2360−E−SP2, 7, 14, 15 ,
QLE2460−E−SP2, 7, 18
218 Fujitsu Siemens Primergy RX220 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E1, 2, 72, 93 , FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES Express, LPe1150−E1, 2, 51, 92 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X AX150
v2.6.9−22.0.2.EL
219 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP101−E1, 2, 13, 51 , LP1050−E1, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express, 3, 51, LP982−E1, 51; FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X 70 AX150
v2.6.9−22.0.2.EL QLogic: QLA200−E−SP2, 7, 26,
QLA210−E−SP2, 7, 26, QLA2340−E−SP6,
7

220 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Dell: 2342M6, 2342M6, 7, LPe1105−M1, 2, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES 17, 51,QME24622, 7, 53 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
221 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES QLogic QLA200−E−SP2, 7, 26 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−22.0.2.EL
9
HPQ Proliant: BL40p, DL360(G3) ,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
222 Dell PowerEdge: 2600, 2650, 6600, 6650 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 13, 51; FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES QLogic QLA200−E−SP7, 26 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL

11/02/2006 304 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
223 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050−E1, 2, 3, 51 FC−AL, EMC Y10, 11
1950, 2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−22.0.2.EL
IBM xSeries: x255, x336 (8837)12, x346
(8840)12, x3850/x366 (8863)62, 63;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
224 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP982−E1, 2, 51 FC−AL, EMC Y10, 11
2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−22.0.2.EL
IBM xSeries: x255, x336 (8837)12, x346
(8840)12, x3850/x366 (8863)62, 63;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
225 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex: LP1050−E1, 3, 51, LP982−E1, 51 FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
HPQ Proliant: BL40p, DL360(G3)9, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
DL360(G4)9, DL5609, DL760 (G2)9, DL7609, v2.6.9−22.0.2.EL
9
ML570(G2) ;
Samsung: SS370, SS3840
226 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 7, 8, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES AE369A/FC1243 (QLA2462)2, 7, 8 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
227 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 51 FC−AL, EMC Y10, 11
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
140Rd−4 v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
228 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 23, 27, 51 FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
229 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA210−E−SP2, 7, 26 FC−AL, EMC Y10, 11
2600, 2650, 6600, 6650; v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−22.0.2.EL
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
230 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP2, 6, 7 FC−AL, EMC Y10, 11
1950; v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−22.0.2.EL
IBM xSeries: x255, x336 (8837)12, x346
(8840)12, x3850/x366 (8863)62, 63;
LangChao: NC2000, NF420;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150;
Sun: V20z, V40z, x4100, x4200
231 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP6, 7 FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.9−22.0.1.EL, U2+ AS/ES AX150
HPQ Proliant: BL40p, DL360(G3)9, v2.6.9−22.0.2.EL
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao: NC2000, NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
232 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic QLA2460−E−SP2, 7, 18 FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL

11/02/2006 305 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
233 Fujitsu Siemens Primergy: RX300 S2, TX200 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X QLogic: QLA200−E−SP2, 7, 26, FC−AL, EMC Y
S2, TX300 S2 v2.6.9−22.EL, U2+ AS/ES QLA210−E−SP2, 7, 26 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
234 IBM xSeries: x3800/x260 (8865)62, 63, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X64 Emulex: LP1050−E1, 2, 3, 51, LP982−E1, FC−AL, EMC Y10, 11
x3950/x3950E/x460 (8872, 8874)62, 63 v2.6.9−22.EL, U2+ AS/ES 2, 51; FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL QLogic QLA2340−E−SP2, 6, 7
235 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 51 , QME24622, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES Express, 7, 53 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES PCI−X AX150
v2.6.9−22.0.2.EL
236 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex LP101−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−22.EL, U2+ AS/ES PCI−X QLogic: QLA200−E−SP2, 7, 26, FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−22.0.1.EL, U2+ AS/ES QLA210−E−SP2, 7, 26 AX150
ML370(G3)9, ML370(G4)9; v2.6.9−22.0.2.EL
Samsung SS140
237 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex LP1050−E1, 2, 51, 72 ; FC−AL, EMC Y
v2.6.9−22.EL, U2+ AS/ES PCI−X QLogic: QLA2340−E−SP2, 6, 7, FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES QLA2340−E−SP6, 7 AX150
v2.6.9−22.0.2.EL
238 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex: LP1050−E1, 2, 3, 51, LP982−E1, FC−AL, EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES PCI−X 2, 51; FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−22.0.1.EL, U2+ AS/ES AX150
8848); v2.6.9−22.0.2.EL QLogic QLA2340−E−SP2, 6, 7
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
239 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, Emulex: LP1050−E1, 3, 51, LP982−E1, 51 FC−AL, EMC Y10, 11
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−22.EL, U2+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
ML370(G3)9, ML370(G4)9 v2.6.9−22.0.2.EL
240 HPQ Proliant: DL380(G4)9, DL3859, DL5859, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 7, 8, FC−AL, EMC Y10, 11
ML370(G4)9 v2.6.9−22.EL, U2+ AS/ES PCI−X AE369A/FC1243 (QLA2462)2, 7, 8 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
241 IBM eServer: 325 (Model 8835), 326 (Model Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, IBM 24P0960 (QLA2340)2, 6, 7, 16 FC−AL, EMC Y10, 11
8848) v2.6.9−22.EL, U2+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
242 HPQ Proliant: DL1459, DL380(G4)9, DL3859, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI, QLogic QLA2340−E−SP6, 7 FC−AL, EMC Y10, 11
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−22.EL, U2+ AS/ES PCI−X FC−SW CLARiiON
ML370(G3)9, ML370(G4)9; v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL
Samsung SS140
243 Fujitsu Siemens Primergy: RX300 S2, TX200 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 2, 72; FC−AL, EMC Y
S2, TX300 S2 v2.6.9−22.EL, U2+ AS/ES QLogic QLA2340−E−SP6 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL, U3 AS/ES
v2.6.9−34.EL, U3+ AS/ES
v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL
244 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 51 ; FC−AL, EMC Y10, 11
v2.6.9−22.EL59, U2+ AS/ES Express QLogic QLE2360−E−SP7, 14, 15 FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
NF520; v2.6.9−22.0.2.EL
Samsung ZSS230
245 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LP101−E1, 13, 51, LP1050−E1, 3, FC−AL, EMC Y10, 11
v2.6.9−22.EL59, U2+ AS/ES Express 51, LP982−E1, 2, 51, LP982−E1, 51; FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL QLogic QLA2340−E−SP6, 7
246 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI Emulex: LPe111−E1, 2, 25, 51 , FC−AL, EMC Y10, 11
v2.6.9−22.EL59, U2+ AS/ES Express LPe1150−E1, 2, 17, 60 ; FC−SW CLARiiON
LangChao: NC3000, NC3500, NF520; v2.6.9−22.0.1.EL, U2+ AS/ES AX150
v2.6.9−22.0.2.EL QLogic: QLE2360−E−SP2, 7, 14, 15 ,
Samsung ZSS230 QLE2460−E−SP2, 7, 18
247 LangChao: NC3000, NC3500, NF500, Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP1050−E1, 2, 3, 51; FC−AL, EMC Y10, 11
NF520; v2.6.9−22.EL59, U2+ AS/ES QLogic QLA2340−E−SP2, 6, 7 FC−SW CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
Samsung ZSS230 v2.6.9−22.0.2.EL
248 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex LP982−E1, 2, 51 FC−AL, EMC Y10, 11
v2.6.9−22.EL59, U2+ AS/ES FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
NF520; v2.6.9−22.0.2.EL
Samsung ZSS230
249 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X Emulex: LP101−E1, 13, 51, LP1050−E1, 3, FC−AL, EMC Y10, 11
v2.6.9−22.EL59, U2+ AS/ES 51, LP982−E1, 51; FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−22.0.1.EL, U2+ AS/ES AX150
NF520 v2.6.9−22.0.2.EL QLogic QLA2340−E−SP6, 7
250 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP101−E1, 2, 13, 52 ; FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−34.EL, U3+ AS/ES QLogic: QLA200−E−SP2, 26, 41, FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; v2.6.9−34.0.1.EL, U3+ AS/ES QLA210−E−SP2, 26, 41 AX150
v2.6.9−34.0.2.EL
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL380(G2)9, DL380(G3)9, DL3809,
DL580(G2)9, DL5809, ML350(G2)9,
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509

11/02/2006 306 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
251 Fujitsu Siemens Primergy BX630: (2−way), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 52, 72 FC−AL, EMC Y
(4−way) v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
252 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP1050−E1, 2, 3, 52, LP982−E1, FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−34.EL, U3+ AS/ES 2, 52; FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450 v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL QLogic QLA2340−E−SP2, 6, 41
253 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP1050−E1, 3, 52, LP982−E1, 52 FC−AL, EMC Y
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
ML530(G3)9, ML5309, ML5709, ML7509 v2.6.9−34.0.2.EL
254 Fujitsu Siemens Primergy: BX620 S3, BX630 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Fujitsu Siemens BX600−FC22Q2, 6, 41, 49 FC−AL, EMC Y
(2−way), BX630 (4−way), BX630 (8−way) v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
255 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI NEC N8190−120 (LP1050)1, 13, 23, 52 FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
256 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic: QLA2340−E−SP6, 41, FC−AL, EMC Y
DL380(G2)9, DL380(G3)9, DL3809, v2.6.9−34.EL, U3+ AS/ES QLE220−E−SP2, 45, 48, 83 FC−SW CLARiiON
DL580(G2)9, DL5809, ML350(G2)9, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
ML350(G3)9, ML3509, ML370(G2)9, ML3709, v2.6.9−34.0.2.EL
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
257 Dell PowerEdge: 1800, 2800, 2850, 6800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP101−E1, 2, 13, 52 ; FC−AL, EMC Y
6850; v2.6.9−34.EL, U3+ AS/ES Express QLogic: QLA200−E−SP2, 26, 41, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES QLA210−E−SP2, 26, 41 AX150
Digital Henge Revo: JS1400, JS2400 v2.6.9−34.0.2.EL
258 Dell PowerEdge: 1800, 2800, 2850 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 3, 52; FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express QLogic QLA2340−E−SP2, 6, 41 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
259 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 52 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.2.EL
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
260 Dell PowerEdge: 1800, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP982−E1, 2, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
Samsung ZSS230 v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
261 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP101−E1, 13, 52, LP1050−E1, 3, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express 52, LP982−E1, 52; FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL QLogic QLA2340−E−SP6, 41
262 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LPe111−E1, 2, 25, 52 , FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES Express LPe1150−E1, 2, 17, 52 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.2.EL
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
263 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.6.9−34.EL, U3+ AS/ES Express 27, 52 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
264 Dell PowerEdge 1950 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP2, 45, 48 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
265 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP2, 45, 48, 83 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
266 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE2360−E−SP2, 14, 15, 41 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.2.EL
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230

11/02/2006 307 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
267 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE2360−E−SP14, 15, 41 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
NF520; v2.6.9−34.0.2.EL
Samsung ZSS230
268 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE2460−E−SP2, 18, 41 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES Express FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.2.EL
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
269 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP101−E1, 2, 13, 52 ; FC−AL, EMC Y
6950; v2.6.9−34.EL, U3+ AS/ES Express, QLogic: QLA200−E−SP2, 26, 41, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X QLA210−E−SP2, 26, 41 AX150
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.2.EL
AS2500;
HPQ Proliant ML350(G4)9;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
270 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 3, 52 FC−AL, EMC Y
6950; v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.2.EL
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
271 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 13, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
AS2500; v2.6.9−34.0.2.EL
Fujitsu Siemens Primergy: RX600 S3, TX600
S3;
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
272 Fujitsu Siemens Primergy RX220 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
v2.6.9−34.0.2.EL
273 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LP982−E1, 2, 52 FC−AL, EMC Y
6950; v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.2.EL
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
274 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LPe111−E1, 2, 25, 52 ; FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, QLogic: QLE2360−E−SP2, 14, 15, 41 , FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X QLE2460−E−SP2, 18, 41 AX150
AS2500; v2.6.9−34.0.2.EL
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
275 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex LPe1150−E1, 2, 17, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
AS2500; v2.6.9−34.0.2.EL
Fujitsu Siemens Primergy: RX220, RX600
S3, TX600 S3;
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
276 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP1050−E1, 3, 52, LP982−E1, 52; FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 8, 35, AX150
v2.6.9−34.0.2.EL AE369A/FC1243 (QLA2462)2, 8, 36;
QLogic QLE220−E−SP2, 45, 48, 83
277 IBM xSeries: x3550 (7978), x3650 (7979) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI IBM: 24P0960 (QLA2340)2, 6, 16, 41 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, 24P8053 (QLA2342)2, 6, 41, 39M5894 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X (QLA2460)2, 39M5895 (QLA2462)2; AX150
v2.6.9−34.0.2.EL
QLogic: QLA2460−E−SP2, 18, 41,
QLE2360−E−SP2, 41, 74,
QLE2460−E−SP2, 41, 73
278 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI NEC: N8190−120 (LP1050)3, 23, 79, 94 , FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.6.9−34.EL, U3+ AS/ES Express, N8190−127 (LPe1150)17, 23, 79, 94 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
v2.6.9−34.0.2.EL

11/02/2006 308 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
279 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP2, 6, 41 FC−AL, EMC Y
6950; v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.2.EL
AS2500;
Fujitsu Siemens Primergy: RX220, RX600
S3, TX600 S3;
IBM xSeries: x3550 (7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
280 Fujitsu Siemens Primergy: RX220, RX600 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP6 FC−AL, EMC Y
S3, TX600 S3 v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
v2.6.9−34.0.2.EL
281 Fujitsu Siemens Primergy: RX220, RX600 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP6, 41 FC−AL, EMC Y
S3, TX600 S3; v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
HPQ Proliant ML350(G4)9 v2.6.9−34.0.2.EL
282 Dell PowerEdge: 1850, 1900, 2850, 2900, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP2, 45, 48 FC−AL, EMC Y
2950, 6800, 6850, 6950; v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
Digital Henge Revo: AS1500, AS1550, v2.6.9−34.0.2.EL
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
283 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI Emulex: LP101−E1, 2, 13, 52 , LP1050−E1, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, 3, 52, LP982−E1, 52; FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X 70 AX150
v2.6.9−34.0.2.EL QLogic: QLA200−E−SP2, 26, 41,
QLA210−E−SP2, 26, 41,
QLA2340−E−SP6, 41, QLE220−E−SP2,
45, 48, 83

284 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Dell: 2342M6, 41, LPe1105−M1, 2, 17, 52 , FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES QME24622, 41, 53 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
285 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 2, 13, 52 ; FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES QLogic QLA200−E−SP2, 26, 41 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−34.0.2.EL
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
286 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 13, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
LangChao: NC3000, NC3500, NF500,
NF520
287 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP1050−E1, 2, 3, 52 FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−34.0.2.EL
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
288 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex LP982−E1, 2, 52 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.2.EL
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200

11/02/2006 309 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
289 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Emulex: LP1050−E1, 3, 52, LP982−E1, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL760 (G2)9, DL7609,
ML570(G2)9;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: SS370, SS3840
290 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(416654−B21), (416655−B21), v2.6.9−34.EL, U3+ AS/ES for HP c−Class Bladesystem: FC−SW CLARiiON
(416656−B21), (432636−B21); v2.6.9−34.0.1.EL, U3+ AS/ES (403621−B21)28, 52, 105 , AX150
v2.6.9−34.0.2.EL (403621−B21)28, 52, 109
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
291 HPQ Proliant BL460c: (416653−B21), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416654−B21), (416655−B21), v2.6.9−34.EL, U3+ AS/ES HP c−Class Bladesystem FC−SW CLARiiON
(416656−B21), (432636−B21); v2.6.9−34.0.1.EL, U3+ AS/ES (403619−B21)24, 36 AX150
v2.6.9−34.0.2.EL
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
292 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 8, 35, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES AE369A/FC1243 (QLA2462)2, 8, 36 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
293 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X NEC N8190−120 (LP1050)1, 13, 23, 52 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
140Rd−4 v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
294 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 23, 27, 52 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
295 Fujitsu Siemens Primergy: RX300 S2, TX200 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP2, 26 FC−AL, EMC Y
S2, TX300 S2 v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
296 Dell PowerEdge: 2600, 2650, 6600, 6650 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP26, 41 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
297 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA210−E−SP2, 26, 41 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−34.0.2.EL
Fujitsu Siemens Primergy: RX300 S2, TX200
S2, TX300 S2;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
298 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP2, 6, 41 FC−AL, EMC Y
1950; v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
Digital Henge SH4500R4; v2.6.9−34.0.2.EL
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
299 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP6, 41 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
300 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLA2460−E−SP2, 18, 41 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL

11/02/2006 310 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
301 Digital Henge SH4500R4; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X QLogic QLE220−E−SP2, 45, 48, 83 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 v2.6.9−34.EL, U3+ AS/ES FC−SW CLARiiON
S2, TX300 S2; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
302 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 17, 52 , QME24622, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, 41, 53 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
v2.6.9−34.0.2.EL
303 Dell PowerEdge: 1800, 2800 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, PCI QLogic QLE220−E−SP2, 45, 48 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES Express, FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES PCI−X AX150
v2.6.9−34.0.2.EL
304 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP101−E1, 2, 13, 52 ; FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−34.EL, U3+ AS/ES PCI−X QLogic: QLA200−E−SP2, 26, 41, FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−34.0.1.EL, U3+ AS/ES QLA210−E−SP2, 26, 41, QLE220−E−SP2, AX150
ML370(G3)9, ML370(G4)9; v2.6.9−34.0.2.EL 45, 48, 83

Samsung SS140
305 Fujitsu Siemens Primergy RX800 S2 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex LP1050−E1, 2, 52, 72 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
306 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E1, 2, 3, 52, LP982−E1, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES PCI−X 2, 52 FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−34.0.1.EL, U3+ AS/ES AX150
8848); v2.6.9−34.0.2.EL
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
307 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, Emulex: LP1050−E1, 3, 52, LP982−E1, 52 FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
ML370(G3)9, ML370(G4)9 v2.6.9−34.0.2.EL
308 HPQ Proliant: DL380(G4)9, DL3859, DL5859, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 8, 35, FC−AL, EMC Y
ML370(G4)9 v2.6.9−34.EL, U3+ AS/ES PCI−X AE369A/FC1243 (QLA2462)2, 8, 36 FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
309 IBM eServer: 325 (Model 8835), 326 (Model Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, IBM 24P0960 (QLA2340)2, 6, 16, 41 FC−AL, EMC Y
8848) v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
310 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP2, 6, 41 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
Fujitsu Siemens Primergy RX800 S2; v2.6.9−34.0.1.EL, U3+ AS/ES AX150
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−34.0.2.EL
8848);
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
311 Fujitsu Siemens Primergy RX800 S2; Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP6, 41 FC−AL, EMC Y
HPQ Proliant: DL1459, DL380(G4)9, DL3859, v2.6.9−34.EL, U3+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−34.0.1.EL, U3+ AS/ES AX150
ML370(G3)9, ML370(G4)9; v2.6.9−34.0.2.EL
Samsung SS140
312 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−42.EL, U4+ AS/ES QLogic: QLA200−E−SP2, 5, 26, FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450; v2.6.9−42.0.2.EL QLA210−E−SP2, 5, 26 AX150
HPQ Proliant: DL3209, DL360(G2)9, DL3609,
DL380(G2)9, DL380(G3)9, DL3809,
DL580(G2)9, DL5809, ML350(G2)9,
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509
313 Dell PowerEdge: 1550, 2300, 2400, 2450, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E1, 2, 3, 4, LP982−E1, 2, FC−AL, EMC Y
2500, 255065, 4300, 4350, 4400, 6100, v2.6.9−42.EL, U4+ AS/ES 4; FC−SW CLARiiON
6300, 6350, 6400, 6450, 8450 v2.6.9−42.0.2.EL AX150
QLogic QLA2340−E−SP2, 5, 6
314 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E1, 3, 4, LP982−E1, 4 FC−AL, EMC Y
DL5809, ML350(G2)9, ML350(G3)9, ML3509, v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
ML370(G2)9, ML3709, ML530(G2)9, v2.6.9−42.0.2.EL AX150
ML530(G3)9, ML5309, ML5709, ML7509
315 NEC Express 5800: 120Rd−1, 120Rf−2, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI NEC N8190−120 (LP1050)1, 4, 13, 23 FC−AL, EMC Y
140Hd, 140Rc−4, 180Rd−4 v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
316 HPQ Proliant: DL3209, DL360(G2)9, DL3609, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic: QLA2340−E−SP5, 6, FC−AL, EMC Y
DL380(G2)9, DL380(G3)9, DL3809, v2.6.9−42.EL, U4+ AS/ES QLE220−E−SP2, 45, 46 FC−SW CLARiiON
DL580(G2)9, DL5809, ML350(G2)9, v2.6.9−42.0.2.EL AX150
ML350(G3)9, ML3509, ML370(G2)9, ML3709,
ML530(G2)9, ML530(G3)9, ML5309, ML5709,
ML7509

11/02/2006 311 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
317 Dell PowerEdge: 1800, 2800, 2850, 6800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
6850; v2.6.9−42.EL, U4+ AS/ES Express QLogic: QLA200−E−SP2, 5, 26, FC−SW CLARiiON
v2.6.9−42.0.2.EL QLA210−E−SP2, 5, 26 AX150
Digital Henge Revo: JS1400, JS2400
318 Dell PowerEdge: 1800, 2800, 2850 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP1050−E1, 2, 3, 4; FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express QLogic QLA2340−E−SP2, 5, 6 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
319 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP1050Ex−E1, 2, 4, 13 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF500,
NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
320 Dell PowerEdge: 1800, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP982−E1, 2, 4 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
Samsung ZSS230 v2.6.9−42.0.2.EL AX150
321 Samsung ZSS230 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP101−E1, 4, 13, LP1050−E1, 3, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express 4,
LP982−E1, 4; FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
QLogic QLA2340−E−SP5, 6
322 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LPe111−E1, 2, 4, 25, FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES Express LPe1150−E1, 2, 4, 17 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)9, DL380(G4)9,
DL580(G3)9, ML350(G4)9, ML370(G4)9;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
323 HPQ Proliant: DL360(G4)9, DL380(G4)9, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, FC−AL, EMC Y
DL580(G3)9, ML350(G4)9, ML370(G4)9 v2.6.9−42.EL, U4+ AS/ES Express 4, 27 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
324 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y10, 11
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES Express for HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), v2.6.9−42.0.2.EL (403621−B21)4, 25, 28 AX150
(432636−B21);
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
325 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y33
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES Express for HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), v2.6.9−42.0.2.EL (403621−B21)4, 28, 34 AX150
(432636−B21);
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
326 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ QLogic QMH2462 4Gb FC HBA for FC−AL, EMC N
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES Express HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), v2.6.9−42.0.2.EL (403619−B21)5, 24 AX150
(432636−B21);
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
327 HPQ Proliant BL460c: (404664−B21), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA FC−AL, EMC Y
(416653−B21), (416654−B21), v2.6.9−42.EL, U4+ AS/ES Express for HP c−Class Bladesystem FC−SW CLARiiON
(416655−B21), (416656−B21), v2.6.9−42.0.2.EL (403621−B21)4, 28, 34, QLogic QMH2462 AX150
(432636−B21); 4Gb FC HBA for HP c−Class
Bladesystem (403619−B21)5, 24
HPQ Proliant BL465c: (403433−B21),
(403434−B21), (407234−B21),
(407235−B21);
HPQ Proliant BL480c: (404704−B21),
(416666−B21), (416667−B21),
(416668−B21), (416669−B21)
328 IBM xSeries x3455 (7984) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI IBM: 42C2069 (LPe11000)1, 2, 4, 27, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express 42C2071 (LPe11002)1, 2, 4, 17; FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
QLogic: QLE2360−E−SP2, 5, 14,
QLE2362−E−SP2, 5, 14,
QLE2462−E−SP2, 5, 18

11/02/2006 312 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
329 Dell PowerEdge 1950; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP2, 45, 46 FC−AL, EMC Y
Digital Henge Revo: JS1400, JS2400 v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
330 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP2, 5, 14, 15 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)12;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
331 Digital Henge INNO: HR−4850, HR−6850; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP5, 14, 15 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
LangChao: NC3000, NC3500, NF500, v2.6.9−42.0.2.EL AX150
NF520;
Samsung ZSS230
332 Dell PowerEdge: 1800, 1850, 1950, 2800, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE2460−E−SP2, 5, 18 FC−AL, EMC Y
2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES Express FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x3455 (7984);
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
333 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
6950; v2.6.9−42.EL, U4+ AS/ES Express, QLogic: QLA200−E−SP2, 5, 26, FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X QLA210−E−SP2, 5, 26 AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
HPQ Proliant ML350(G4)9;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
334 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP1050−E1, 2, 3, 4; FC−AL, EMC Y
6950; v2.6.9−42.EL, U4+ AS/ES Express, QLogic QLA2340−E−SP2, 5, 6 FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
IBM xSeries: x3550 (7978), x3650 (7979),
x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
335 Dell PowerEdge: 2900, 2950, 6800, 6850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex LP982−E1, 2, 4 FC−AL, EMC Y
6950; v2.6.9−42.EL, U4+ AS/ES Express, FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
336 HPQ Proliant ML350(G4)9 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050−E1, 3, 4, LP982−E1, 4; FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 5, 8, AX150
AE369A/FC1243 (QLA2462)2, 5, 8;
QLogic QLA2340−E−SP5, 6
337 Dell PowerEdge: 2900, 2950, 6950; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP1050Ex−E1, 2, 4, 13, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, LPe111−E1, 2, 4, 25, LPe1150−E1, 2, 4, 17; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, v2.6.9−42.0.2.EL PCI−X AX150
AS2500; QLogic: QLE2360−E−SP2, 5, 14, 15 ,
QLE2460−E−SP2, 5, 18
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
338 IBM xSeries: x3550 (7978), x3650 (7979), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI IBM: 24P0960 (QLA2340)2, 5, 6, 16, FC−AL, EMC Y
x3755 (8877) v2.6.9−42.EL, U4+ AS/ES Express, 24P8053 (QLA2342)2, 5, 6; FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
QLogic: QLA2460−E−SP2, 5, 18,
QLE2360−E−SP2, 5, 74,
QLE2460−E−SP2, 5, 73
339 NEC Express 5800: 120Li, 120Rg−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI NEC: N8190−120 (LP1050)3, 4, 23, 79 , FC−AL, EMC Y
120Ri−2, 140Hf, 140Re−4 v2.6.9−42.EL, U4+ AS/ES Express, N8190−127 (LPe1150)4, 17, 23, 79 FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
340 Dell PowerEdge: 1850, 1900, 2850, 2900, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP2, 45, 46 FC−AL, EMC Y
2950, 6800, 6850, 6950; v2.6.9−42.EL, U4+ AS/ES Express, FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
HPQ Proliant ML350(G4)9;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 313 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
341 Digital Henge Revo: JS1400, JS2400 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI Emulex: LP101−E1, 2, 4, 13, LP1050−E1, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, 3, 4, LP982−E1, 4; FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X70 AX150
QLogic: QLA200−E−SP2, 5, 26,
QLA210−E−SP2, 5, 26, QLA2340−E−SP5,
6, QLE220−E−SP2, 45, 46

342 Dell PowerEdge 1855 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Dell: 2342M5, 6, LPe1105−M1, 2, 4, 17, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES QME24622, 5, 53 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
343 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES QLogic QLA200−E−SP2, 5, 26 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
9
HPQ Proliant: BL40p, DL360(G3) ,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
344 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP101−E1, 4, 13 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.2.EL AX150
LangChao: NC3000, NC3500, NF500,
NF520
345 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP1050−E1, 2, 3, 4 FC−AL, EMC Y
1950, 2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
12
IBM xSeries: x255, x336 (8837) , x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
346 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex LP982−E1, 2, 4 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
347 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Emulex: LP1050−E1, 3, 4, LP982−E1, 4 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.2.EL AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL760 (G2)9, DL7609,
ML570(G2)9;
LangChao: NC3000, NC3500, NF500,
NF520;
Samsung: SS370, SS3840
348 HPQ Proliant DL360(G4)9 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 5, 8, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES AE369A/FC1243 (QLA2462)2, 5, 8 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
349 NEC Express 5800: 120Lh, 120Re−1, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−120 (LP1050)1, 4, 13, 23 FC−AL, EMC Y
120Rf−1, 120Rg−2, 120Rh−2, 140He, v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
140Rd−4 v2.6.9−42.0.2.EL AX150
350 NEC Express 5800: 140He, 140Rd−4 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 4, 23, 27 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
351 Dell PowerEdge: 2600, 2650, 6600, 6650 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA200−E−SP5, 26 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
352 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA210−E−SP2, 5, 26 FC−AL, EMC Y
2600, 2650, 6600, 6650; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840

11/02/2006 314 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
353 Dell PowerEdge: 1600SC, 1650, 1750, 1850, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA2340−E−SP2, 5, 6 FC−AL, EMC Y
1950; v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336 (8837)12, x346
(8840)12;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230;
Sun: V20z, V40z, x4100, x4200
354 Dell PowerEdge: 2600, 2650, 6600, 6650; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA2340−E−SP5, 6 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
Digital Henge INNO: HR−4850, HR−6850; v2.6.9−42.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao: NC2000, NC3000, NC3500,
NF420, NF500, NF520;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
355 Sun: x4100, x4200 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLA2460−E−SP2, 5, 18 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
356 Digital Henge SH4500R4; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X QLogic QLE220−E−SP2, 45, 46 FC−AL, EMC Y
Fujitsu Siemens Primergy: RX300 S2, TX200 v2.6.9−42.EL, U4+ AS/ES FC−SW CLARiiON
S2, TX300 S2; v2.6.9−42.0.2.EL AX150
HPQ Proliant: BL40p, DL360(G3)9,
DL360(G4)9, DL5609, DL7409, DL760 (G2)9,
DL7609, ML570(G2)9;
LangChao NF420;
Lenovo SureServer: R630 6004, T630 6003;
Samsung: SS210, SS370, SS3840
357 Dell PowerEdge 1955 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 4, 17, QME24622, 5, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, 53 FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
358 HPQ Proliant: DL380(G5), DL580(G4) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI Emulex: LP101−E1, 2, 4, 13, LP1050−E1, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, 3, 4, LP982−E1, 4, LPe111−E1, 2, 4, 25, FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X LPe1150−E1, 2, 4, 17; AX150
HPQ: A8002A/FC2142SR (LPe1150)1, 2,
4, 27, AE311A/FC1142SR (QLE2460)2, 5,
18, AE312A/FC1242SR (QLE2462)2, 5,
18;

QLogic: QLA200−E−SP2, 5, 26,


QLA210−E−SP2, 5, 26, QLA2340−E−SP5,
6,
QLE2460−E−SP2, 5, 18,
QLE2462−E−SP2, 5, 18
359 HPQ Proliant DL380(G5) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI HPQ: AB429A/FC1143 (QLA2460)2, 5, 8, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, AE369A/FC1243 (QLA2462)2, 5, 8 FC−SW CLARiiON
v2.6.9−42.0.2.EL PCI−X AX150
360 Dell PowerEdge: 1800, 2800; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP2, 45, 46 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES Express, FC−SW CLARiiON
HPQ Proliant: DL380(G5), DL580(G4) v2.6.9−42.0.2.EL PCI−X AX150
361 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex LP101−E1, 2, 4, 13; FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−42.EL, U4+ AS/ES PCI−X QLogic: QLA200−E−SP2, 5, 26, FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−42.0.2.EL QLA210−E−SP2, 5, 26, QLE220−E−SP2, AX150
ML370(G3)9, ML370(G4)9; 45, 46

Samsung SS140
362 Dell PowerEdge: 1800, 1850, 2800, 2850; Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E1, 2, 3, 4, LP982−E1, 2, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES PCI−X 4; FC−SW CLARiiON
IBM eServer: 325 (Model 8835), 326 (Model v2.6.9−42.0.2.EL AX150
8848); QLogic QLA2340−E−SP2, 5, 6
IBM xSeries: x365, x440, x445 (8870);
Samsung: ES470, ES570, SS140
363 HPQ Proliant: DL1459, DL380(G2)9, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, Emulex: LP1050−E1, 3, 4, LP982−E1, 4 FC−AL, EMC Y
DL380(G3)9, DL380(G4)9, DL3809, DL3859, v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−42.0.2.EL AX150
ML370(G3)9, ML370(G4)9
364 HPQ Proliant: DL380(G4)9, DL3859, DL5859, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)2, 5, 8, FC−AL, EMC Y
ML370(G4)9 v2.6.9−42.EL, U4+ AS/ES PCI−X AE369A/FC1243 (QLA2462)2, 5, 8 FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150
365 IBM eServer: 325 (Model 8835), 326 (Model Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, IBM 24P0960 (QLA2340)2, 5, 6, 16 FC−AL, EMC Y
8848) v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
v2.6.9−42.0.2.EL AX150

11/02/2006 315 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
366 HPQ Proliant: DL1459, DL380(G4)9, DL3859, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI, QLogic QLA2340−E−SP5, 6 FC−AL, EMC Y
DL580(G2)9, DL580(G3)9, DL5859, v2.6.9−42.EL, U4+ AS/ES PCI−X FC−SW CLARiiON
ML370(G3)9, ML370(G4)9; v2.6.9−42.0.2.EL AX150
Samsung SS140
367 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X IBM HS20 FC Exp Card (26K4841)2, 6, FC−SW EMC Y11, 47
v2.4.21−32.EL30, 97, 98, 95, 100 CLARiiON
v2.4.21−32.EL30, 98; AX150
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
368 IBM BladeCenter HS20 (Model: 8678)19, Red Hat RHEL [32−Bit] 3.0 U5 AS/ES: PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, FC−SW EMC Y11, 47
8832)19, 8832−N1X), 8843); v2.4.21−32.EL30, 97, 98, 95, 100, (48P7061)2, 6, 95, 100 CLARiiON
v2.4.21−32.EL30, 98; AX150
IBM BladeCenter HS40 (Model 8839)
Red Hat RHEL [32−Bit] 3.0 U5+ AS/ES
v2.4.21−32.0.1.EL30, 98
369 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−40.EL30, 31 port: for NovaScale Blade Series CLARiiON
CFSN202−110037, 75, 83, mini for AX150
NovaScale Blade 2021
CFSN202−210037, 75, 83;
Bull: SBEFCM (SFF) Mezzanine HBA37,
75, 83, SBEFCM4 (SFF) 4Gb Mezzanine
HBA22, 37, 83
370 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X Digital Henge Digital Henge: SBEFCM42, FC−SW EMC Y
v2.4.21−40.EL30, 31 22, 37, SBEFCM37, 75, 83 , SBFCM37, 75, CLARiiON
83; AX150
Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD2, 37, 40, 83
371 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
8843); v2.4.21−40.EL30, 31 Card (39Y9186)2, 32, 67, 78 CLARiiON
AX150
IBM BladeCenter LS20 (Model 8850)
372 IBM BladeCenter: HS20 (Model 8843), LS20 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
(Model 8850) v2.4.21−40.EL30, 31 (26R0890)2, 22, 29 CLARiiON
AX150
373 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)2, 6, 29 FC−SW EMC Y
v2.4.21−40.EL30, 31 CLARiiON
AX150
374 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−40.EL30, 31 29, (48P7061)2, 6, 29 CLARiiON
AX150
IBM BladeCenter HS40 (Model 8839)
375 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) for FC−SW EMC Y
v2.4.21−40.EL30, 31 IBM eServer LS202, 6, 29, SFF Exp Card CLARiiON
(26K4841) for IBM eServer LS202, 6, 29 AX150
376 IBM BladeCenter HS21 (Model 8853)69 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel FC−SW EMC Y66
v2.4.21−40.EL30, 31 Exp Card (39Y9186)2, 32, 67, 68 , HS20 CLARiiON
4GB SFF FC Exp Card (26R0890)2, 21, AX150
22, 29, HS20 FC Exp Card (13N2203)2, 6,
29, HS20 FC Exp Card (48P7061)2, 6, 29

377 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U7 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−40.EL30, 31 32, 61, HS20 4GB Standard FC Exp Card CLARiiON
(26R0884)2, 20, 29 AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
378 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−47.EL30, 31 port: for NovaScale Blade Series CLARiiON
CFSN202−110040, 43, mini for NovaScale AX150
Blade 2021 CFSN202−210040, 43, mini
for NovaScale Blade 2021
CFSN202−210075, 76;
Bull: SBEFCM (SFF) Mezzanine HBA40,
43, SBEFCM4 (SFF) 4Gb Mezzanine
HBA39, 43
379 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X Digital Henge Digital Henge: SBEFCM42, FC−SW EMC Y
v2.4.21−47.EL30, 31 39, 43, SBEFCM40, 43, SBFCM40, 43; CLARiiON
AX150
Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD2, 40, 43
380 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM Emulex 4Gb SFF Fibre Channel Exp FC−SW EMC Y
8843); v2.4.21−47.EL30, 31 Card (39Y9186)2, 38, 67, 78 CLARiiON
AX150
IBM BladeCenter: LS20 (Model 8850), LS21
(Model 7971), LS41 (Model 7972)
381 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−47.EL30, 31 44, (48P7061)2, 6, 44 CLARiiON
AX150
IBM BladeCenter HS40 (Model 8839)
382 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) for FC−SW EMC Y
v2.4.21−47.EL30, 31 IBM eServer LS202, 6, 44, SFF Exp Card CLARiiON
(26K4841) for IBM eServer LS202, 6, 44 AX150
383 IBM BladeCenter: HS20 (Model 8843), LS20 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y
(Model 8850), LS21 (Model 7971), LS41 v2.4.21−47.EL30, 31 (26R0890)2, 22, 44, FC Exp Card CLARiiON
(Model 7972) (26K4841)2, 6, 44 AX150
384 IBM BladeCenter HS21 (Model 8853)69 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel FC−SW EMC Y66
v2.4.21−47.EL30, 31 Exp Card (39Y9186)2, 38, 67, 68 , HS20 CLARiiON
4GB SFF FC Exp Card (26R0890)2, 21, AX150
22, 44, HS20 FC Exp Card (13N2203)2, 6,
44, HS20 FC Exp Card (48P7061)2, 6, 44

11/02/2006 316 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
385 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0 U8 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−47.EL30, 31 38, 61, HS20 4GB Standard FC Exp Card CLARiiON
(26R0884)2, 20, 44 AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
386 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y11, 47
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES 54, 61 CLARiiON
v2.4.21−37.0.1.EL AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
387 IBM BladeCenter: HS20 (Model 8843), LS20 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC N11, 47
(Model 8850) v2.4.21−37.EL, U6+ AS/ES (26R0890)2, 22, 29 CLARiiON
v2.4.21−37.0.1.EL AX150
388 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC N11, 47
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES (26R0884)2, 20, 29 CLARiiON
v2.4.21−37.0.1.EL AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
389 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)2, 6, 29 FC−SW EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES CLARiiON
v2.4.21−37.0.1.EL AX150
390 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, FC−SW EMC Y11, 47
8678)19, 8832)19, 8832−N1X), 8843); v2.4.21−37.EL, U6+ AS/ES 29,(48P7061)2, 6, 29 CLARiiON
v2.4.21−37.0.1.EL AX150
IBM BladeCenter HS40 (Model 8839)
391 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) for FC−SW EMC Y11, 47
v2.4.21−37.EL, U6+ AS/ES IBM eServer LS202, 6, 29, SFF Exp Card CLARiiON
v2.4.21−37.0.1.EL (26K4841) for IBM eServer LS202, 6, 29 AX150
392 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−37.EL, U6+ AS/ES port for NovaScale Blade Series: CLARiiON
v2.4.21−37.0.1.EL; CFSN202−110075, 76, 86, 87 , AX150
CFSN202−110075, 76, 88, 89, 90 ,
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES CFSN202−110075, 76, 88, 90 ;
v2.6.9−22.EL, U2+ AS/ES
v2.6.9−22.0.1.EL, U2+ AS/ES Bull 2Gbps FC Mezzanine Card − Dual
v2.6.9−22.0.2.EL port mini for NovaScale Blade 2021:
CFSN202−210075, 76, 86, 87 ,
CFSN202−210075, 76, 88, 89, 90 ,
CFSN202−210075, 76, 88, 90 ;
Bull SBEFCM (SFF) Mezzanine: HBA2,
75, 76, 86, 87 , HBA2, 75, 76, 88, 89, 90 , HBA2,
75, 76, 88, 90

393 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull SBEFCM (SFF) Mezzanine HBA2, 75, FC−SW EMC Y
v2.4.21−40.EL30, 31, U8 AS/ES 76 CLARiiON
v2.4.21−47.EL30, 31 AX150
394 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 3.0: U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−40.EL30, 31, U8 AS/ES port for NovaScale Blade Series CLARiiON
v2.4.21−47.EL30, 31; CFSN202−110075 AX150
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES
v2.6.9−34.EL, U3+ AS/ES
v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL
395 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, 7, FC−SW EMC Y10, 11
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−22.EL, U2+ AS/ES (48P7061)2, 6, 7 CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES AX150
IBM BladeCenter HS40 (Model 8839) v2.6.9−22.0.2.EL
396 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES (26R0890)2, 21, 22, 58 , FC Exp Card CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES (26K4841)2, 6, 7 AX150
v2.6.9−22.0.2.EL
397 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y10, 11
v2.6.9−22.EL, U2+ AS/ES (26R0890)2, 22, FC Exp Card (13N2203) CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES for IBM eServer LS202, 6, 7, FC SFF Exp AX150
v2.6.9−22.0.2.EL Card (26K4841) for IBM eServer LS202,
6, 7

398 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U2 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y10, 11
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−22.EL, U2+ AS/ES 51, 61, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−22.0.1.EL, U2+ AS/ES (26R0884)2, 7, 20 AX150
IBM BladeCenter: HS40 (Model 8839), LS20 v2.6.9−22.0.2.EL
(Model 8850)
399 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES port: for NovaScale Blade Series CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES CFSN202−110040, 41, mini for NovaScale AX150
v2.6.9−34.0.2.EL Blade 2021 CFSN202−210040, 42;
Bull SBEFCM (SFF) Mezzanine: HBA2,
75, HBA40, 41;

Bull SBEFCM4 (SFF) 4Gb Mezzanine


HBA39, 41
400 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X Digital Henge Digital Henge: SBEFCM42, FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES 39, 41, SBEFCM40, 41, SBFCM40, 41; CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD2, 40, 41
401 IBM BladeCenter: HS20 (Model 8843), HS21 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
(Model 8853)69 v2.6.9−34.EL, U3+ AS/ES (26R0890)2, 21, 22, 41 CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL

11/02/2006 317 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
402 IBM BladeCenter: HS21 (Model 8853)69, Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
LS20 (Model 8850) v2.6.9−34.EL, U3+ AS/ES (26R0890)2, 22, 41 CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
403 IBM BladeCenter HS20 (Model 8843) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)2, 6, 41 FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
v2.6.9−34.0.2.EL
404 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 6, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−34.EL, U3+ AS/ES 41, (48P7061)2, 6, 41 CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES AX150
IBM BladeCenter: HS21 (Model 8853)69, v2.6.9−34.0.2.EL
HS40 (Model 8839)
405 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) for FC−SW EMC Y
v2.6.9−34.EL, U3+ AS/ES IBM eServer LS202, 6, 41, SFF Exp Card CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES (26K4841) for IBM eServer LS202, 6, 41 AX150
v2.6.9−34.0.2.EL
406 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U3 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−34.EL, U3+ AS/ES 52, 61, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−34.0.1.EL, U3+ AS/ES (26R0884)2, 20, 41 AX150
IBM BladeCenter: HS40 (Model 8839), LS20 v2.6.9−34.0.2.EL
(Model 8850)
407 Bull NovaScale 2320 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES port for NovaScale Blade Series: CLARiiON
v2.6.9−42.0.2.EL CFSN202−11005, 40, CFSN202−11005, AX150
75;

Bull 2Gbps FC Mezzanine Card − Dual


port mini for NovaScale Blade 2021:
CFSN202−21005, 40, CFSN202−21005,
75;

Bull SBEFCM (SFF) Mezzanine: HBA2, 5,


75, HBA5, 40;

Bull SBEFCM4 (SFF) 4Gb Mezzanine


HBA5, 39
408 Digital Henge PowerBlade BS200L Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X Digital Henge Digital Henge: SBEFCM42, FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES 5, 39, SBEFCM5, 40, SBFCM5, 40; CLARiiON
v2.6.9−42.0.2.EL AX150
Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD2, 5, 40
409 IBM BladeCenter: HS20 (Model 8843), HS21 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
(Model 8853)69 v2.6.9−42.EL, U4+ AS/ES (26R0890)2, 5, 21, 22 CLARiiON
v2.6.9−42.0.2.EL AX150
410 IBM BladeCenter: HS21 (Model 8853)69, Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card FC−SW EMC Y
LS20 (Model 8850), LS21 (Model 7971), v2.6.9−42.EL, U4+ AS/ES (26R0890)2, 5, 22 CLARiiON
LS41 (Model 7972) v2.6.9−42.0.2.EL AX150
411 IBM BladeCenter: HS20 (Model 8843), LS20 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)2, 5, 6 FC−SW EMC Y
(Model 8850), LS21 (Model 7971), LS41 v2.6.9−42.EL, U4+ AS/ES CLARiiON
(Model 7972) v2.6.9−42.0.2.EL AX150
412 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)2, 5, 6, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−42.EL, U4+ AS/ES (48P7061)2, 5, 6 CLARiiON
v2.6.9−42.0.2.EL AX150
IBM BladeCenter: HS21 (Model 8853)69,
HS40 (Model 8839)
413 IBM BladeCenter LS20 (Model 8850) Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM HS20 FC: Exp Card (13N2203) for FC−SW EMC Y
v2.6.9−42.EL, U4+ AS/ES IBM eServer LS202, 5, 6, SFF Exp Card CLARiiON
v2.6.9−42.0.2.EL (26K4841) for IBM eServer LS202, 5, 6 AX150
414 IBM BladeCenter HS20 (Model: 7981), Red Hat RHEL [32−Bit] 4.0: U4 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, FC−SW EMC Y
8678)19, 8832)19, 8832−N1X), 8843); v2.6.9−42.EL, U4+ AS/ES 4, 61, HS20 4GB Standard FC Exp Card CLARiiON
v2.6.9−42.0.2.EL (26R0884)2, 5, 20 AX150
IBM BladeCenter: HS40 (Model 8839), LS20
(Model 8850)
415 Bull NovaScale 2320 Red Hat RHEL [32−Bit]: 3.0 U7 AS/ES PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.4.21−40.EL30, 31, 4.0 U3 AS/ES port mini for NovaScale Blade 2021 CLARiiON
v2.6.9−34.EL, 4.0 U3+ AS/ES CFSN202−210075 AX150
v2.6.9−34.0.1.EL, 4.0 U3+ AS/ES
v2.6.9−34.0.2.EL
1. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. SNIA HBA API Supported.
3. Firmware Version 1.91a5
4. Driver Version 8.0.16.27 Driver is integrated into the kernel.
5. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
6. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
10. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
11. VxVM is not supported on servers booting from the array.
12. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
13. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
14. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. This HBA is equivalent to the QLogic QLA2340.
17. Firmware Version 2.50a6
18. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
20. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. BIOS 1.12
23. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
24. BIOS 1.16
25. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
26. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

11/02/2006 318 CLARiiON AX150


CLARiiON AX150

28. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
29. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
30. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
31. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
32. Driver Version 7.3.3 Driver is integrated into the kernel.
33. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
34. Firmware Version 2.50a8
35. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
36. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
37. Driver Version 7.07.00
38. Driver Version 7.3.6 Driver is integrated into the kernel.
39. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
40. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com
41. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
42. Driver Version 8.01.−2−d4 Driver is integrated into the kernel.
43. Driver Version 7.07.04b6 Driver is integrated into the kernel.
44. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
45. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
46. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
47. Booting from the SAN with PowerPath is not supported.
48. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
49. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
50. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
51. Driver Version 8.0.16.17 Driver is integrated into the kernel.
52. Driver Version 8.0.16.18 Driver is integrated into the kernel.
53. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
54. Driver Version 7.3.2 Driver is integrated into the kernel.
55. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
56. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
57. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
58. Driver Version 8.01.00
59. dual core machine not support
60. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
61. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
62. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
63. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
64. Accepts PCI−X 1.0 and 2.0 HBAs.
65. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
66. PowerPath is not supported.
67. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
68. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
69. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
70. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
71. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
72. Firmware Version 1.91a1
73. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
74. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
75. BIOS 1.43
76. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
77. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
78. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
79. BIOS 1.70a3
80. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
81. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
82. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
83. Driver/BIOS are available at http://www.qlogic.com
84. BIOS 1.02
85. Driver Version 7.07.05
86. Driver Version 9.1.2.11
87. Driver Version 9.1.2.10
88. Driver Version 9.1.2.15 STORPort Miniport Driver
89. Driver Version 9.1.2.11 END OF LIFE NOTICE: SCSI miniport and SCSI full port drivers are frozen and EOL at this time for Windows 2003 operating systems. EMC recommends
migrating to the currently supported STORPort driver for your HBA. EMC will continue to support existing customers who have Windows 2003 SCSI drivers installed, but any fixes or
HCL support will require an upgrade to STORPort. Refer to SalesAdvantage articles for the benefits of using STORPort drivers and information on migrating from SCSI to STOR under
Windows 2003. SCSI drivers listed in the April 2006 ESM will be the last supported SCSI drivers for Windows 2003. SCSI Miniport (SCSIPort) Driver. EMC recommends using
STORPort drivers where available.
90. Driver Version 9.1.2.16 STORPort Miniport Driver
91. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
92. Firmware Version 2.50a4 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
93. Driver Version 8.01.16.17
94. Driver Version 8.0.16.18
95. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
96. Driver Version 7.01.01 Driver is integrated into the kernel.
97. Tested as an installable file system on a Linux cluster
Ibrix Fusion File system version 1.3 is supported with this configuration.
FusionFS Server Appliance Requirements:
CPU− x86, Xeon, 3+GHz, 2GB RAM
SMP Not Supported
NIC −Intel Pro 1000 Server adapter with 5.2.39 or BroadcomBCM5700
Please check E−Lab Navigator for the latest version of PowerPath supported on this configuration.
98. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file
names must be used.
99. Driver Version 7.1.14 Driver is integrated into the kernel.
100. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
101. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
102. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
103. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com
104. Driver Version 7.1.14
105. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
106. Driver Version 7.03.00
107. Driver Version 7.03.00 QLogic driver obtained from http://www.qlogic.com
108. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
109. Firmware Version 2.50a8 Driver is integrated into the kernel.
110. Driver Version 8.0.16.6_x2
111. Driver Version 8.0.16.6_x2−2

11/02/2006 319 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [AMD−64]

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0 PCI Emulex: LP101−E6, 8, 23, 33 , LP1050−E6, 8, 17, 33 , LP982−E6, 8, 33; FC−AL, EMC Y
U7 AS/ES v2.4.21−40.EL21, 32 Express, FC−SW CLARiiON
PCI−X QLogic: QLA200−E−SP6, 9, 62, QLA210−E−SP6, 9, 43, AX150
QLA2340−E−SP6, 11, 43
2 Dell PowerEdge 6950; Red Hat RHEL [AMD−64] 3.0 PCI Emulex: LP1050Ex−E6, 8, 23, 33 , LPe111−E4, 6, 8, 33, LPe1150−E6, 8, 24, FC−AL, EMC Y
IBM eServer 326m U7 AS/ES v2.4.21−40.EL21, 32 Express, 33; FC−SW CLARiiON
(Model 7969) PCI−X AX150
QLogic: QLE2360−E−SP6, 30, 31, 43 , QLE2460−E−SP6, 25, 43
3 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0 PCI−X Emulex: LP101−E6, 8, 23, 33 , LP1050−E6, 8, 17, 33 , LP982−E6, 8, 33; FC−AL, EMC Y
x4100, x4200 U7 AS/ES v2.4.21−40.EL21, 32 FC−SW CLARiiON
QLogic: QLA200−E−SP6, 9, QLA210−E−SP6, 9, 43, QLA2340−E−SP11, AX150
QLE220−E−SP6, 29, 53, 54
4 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC Y
U7 AS/ES v2.4.21−40.EL21, 32 381881−B2118, 43, Emulex−based BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B218, 33, 41, 42 AX150
5 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0 PCI, Emulex: LP101−E6, 8, 23, 33 , LP1050−E8, 17, 33, LP982−E8, 33; FC−AL, EMC Y
DL14528, DL38528, U7 AS/ES v2.4.21−40.EL21, 32 PCI−X FC−SW CLARiiON
DL58528 QLogic: QLA200−E−SP6, 9, QLA210−E−SP6, 9, 43, QLA2340−E−SP11, AX150
QLE220−E−SP6, 29, 53, 54
6 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 3.0 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y2, 3
(403433−B21), U8 AS/ES v2.4.21−47.EL21, 32 Express (403621−B21)4, 5, 37 FC−SW CLARiiON
(403434−B21), AX150
(407234−B21),
(407235−B21)
7 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 3.0 PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), U8 AS/ES v2.4.21−47.EL21, 32 Express (403619−B21)34, 40 FC−SW CLARiiON
(403434−B21), AX150
(407234−B21),
(407235−B21)
8 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0 PCI Emulex: LP101−E6, 8, 23, 37 , LP1050−E6, 8, 17, 37 , LP982−E6, 8, 37; FC−AL, EMC Y
U8 AS/ES v2.4.21−47.EL21, 32 Express, FC−SW CLARiiON
PCI−X QLogic: QLA200−E−SP6, 9, 40, QLA210−E−SP6, 9, 40, AX150
QLA2340−E−SP6, 11, 40, QLE2360−E−SP6, 31, 40
9 IBM xSeries x3755 Red Hat RHEL [AMD−64] 3.0 PCI Emulex: LP1050−E6, 8, 17, 37 , LP1050Ex−E6, 8, 23, 37 ; FC−AL, EMC Y58
(8877) U8 AS/ES v2.4.21−47.EL21, 32 Express, FC−SW CLARiiON
PCI−X IBM: 24P0960 (QLA2340)6, 11, 14, 40 , 24P8053 (QLA2342)6, 11, 40, AX150
39M5894 (QLA2460)6, 25, 40, 39M5895 (QLA2462)6, 25, 40;
QLogic: QLA2340−E−SP6, 11, 40, QLA2460−E−SP6, 25, 40,
QLE2360−E−SP6, 31, 40, QLE2460−E−SP6, 25, 40
10 Dell PowerEdge 6950; Red Hat RHEL [AMD−64] 3.0 PCI Emulex: LP1050Ex−E6, 8, 23, 37 , LPe111−E4, 6, 8, 37, LPe1150−E6, 8, 24, FC−AL, EMC Y
IBM eServer 326m U8 AS/ES v2.4.21−47.EL21, 32 Express, 37; FC−SW CLARiiON
(Model 7969) PCI−X AX150
QLogic QLE2460−E−SP6, 25, 40
11 IBM eServer 326m Red Hat RHEL [AMD−64] 3.0 PCI QLogic QLE2360−E−SP6, 30, 31, 40 FC−AL, EMC Y
(Model 7969) U8 AS/ES v2.4.21−47.EL21, 32 Express, FC−SW CLARiiON
PCI−X AX150
12 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0 PCI−X Emulex: LP101−E6, 8, 23, 37 , LP1050−E6, 8, 17, 37 , LP982−E6, 8, 37; FC−AL, EMC Y
x4100, x4200 U8 AS/ES v2.4.21−47.EL21, 32 FC−SW CLARiiON
QLogic: QLA200−E−SP6, 9, 40, QLA210−E−SP6, 9, 40, AX150
QLA2340−E−SP11, 40, QLE220−E−SP6, 53, 54
13 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0 PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC Y
U8 AS/ES v2.4.21−47.EL21, 32 381881−B2118, 40, Emulex−based BL25/30/35/45p Fibre Channel FC−SW CLARiiON
Mezzanine HBA − 394588−B218, 37, 41, 42 AX150
14 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0 PCI, Emulex: LP101−E6, 8, 23, 37 , LP1050−E8, 17, 37, LP982−E8, 37; FC−AL, EMC Y
DL14528, DL38528, U8 AS/ES v2.4.21−47.EL21, 32 PCI−X FC−SW CLARiiON
DL58528 QLogic: QLA200−E−SP6, 9, 40, QLA210−E−SP6, 9, 40, AX150
QLA2340−E−SP11, 40, QLE220−E−SP6, 53, 54
15 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: PCI−X HPQ Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC N3, 15
U5 AS/ES v2.4.21−32.EL21, 22, 381881−B2118, 19, 20 FC−SW CLARiiON
U5+ AS/ES AX150
v2.4.21−32.0.1.EL21, 22
16 IBM eServer 326m Red Hat RHEL [AMD−64] 3.0: PCI Emulex: LP1050Ex−E6, 8, 23, 56 , LPe111−E4, 6, 8, 56, LPe1150−E6, 8, 24, FC−AL, EMC Y3, 15
(Model 7969) U6 AS/ES v2.4.21−37.EL, U6+ Express, 56; FC−SW CLARiiON
AS/ES v2.4.21−37.0.1.EL PCI−X AX150
QLogic: QLE2360−E−SP6, 30, 31, 43 , QLE2460−E−SP6, 25, 43
17 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 3.0: PCI−X Emulex: LP101−E6, 8, 23, 51 , LP1050−E6, 8, 17, 51 , LP982−E6, 8, 51; FC−AL, EMC N3, 15
x4100, x4200 U6 AS/ES v2.4.21−37.EL, U6+ FC−SW CLARiiON
AS/ES v2.4.21−37.0.1.EL QLogic: QLA200−E−SP6, 9, QLA210−E−SP6, 9, 43, QLA2340−E−SP11, AX150
52

18 HPQ Proliant BL45p Red Hat RHEL [AMD−64] 3.0: PCI−X HPQ: Dual−port Fibre Channel Adapter for HP Proliant BL25p/BL45p FC−AL, EMC Y3, 15
U6 AS/ES v2.4.21−37.EL, U6+ 381881−B2118, 43, Emulex−based BL25/30/35/45p Fibre Channel FC−SW CLARiiON
AS/ES v2.4.21−37.0.1.EL Mezzanine HBA − 394588−B218, 41, 42, 56 AX150
19 HPQ Proliant: Red Hat RHEL [AMD−64] 3.0: PCI, Emulex: LP101−E6, 8, 23, 51 , LP1050−E8, 17, 51, LP982−E8, 51; FC−AL, EMC N3, 15
DL14528, DL38528, U6 AS/ES v2.4.21−37.EL, U6+ PCI−X FC−SW CLARiiON
DL58528 AS/ES v2.4.21−37.0.1.EL QLogic: QLA200−E−SP6, 9, QLA210−E−SP6, 9, 43, QLA2340−E−SP11, AX150
52

20 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 3.0: PCI QLogic QLE220−E−SP6, 27, 57 FC−AL, EMC Y
U7 AS/ES v2.4.21−40.EL21, 32, Express, FC−SW CLARiiON
U8 AS/ES v2.4.21−47.EL21, 32 PCI−X AX150
21 Sun: V20z, V40z Red Hat RHEL [AMD−64] 4.0 PCI−X Emulex: LP1050−E6, 8, 16, 17 , LP982−E6, 8, 16; FC−AL, EMC Y3, 15
U1 AS/ES v2.6.9−11.EL13 FC−SW CLARiiON
QLogic QLA2340−E−SP6, 11, 12 AX150
22 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP101−E6, 8, 16, 23 , LP1050−E8, 16, 17, LP982−E8, 16; FC−AL, EMC N3, 15
DL14528, DL38528, U1 AS/ES v2.6.9−11.EL13 PCI−X FC−SW CLARiiON
DL58528 QLogic: QLA200−E−SP6, 9, 12, QLA2340−E−SP11, 12 AX150

11/02/2006 320 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
23 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0 PCI, Emulex: LP1050−E6, 8, 16, 17 , LP982−E6, 8, 16; FC−AL, EMC Y3, 15
(Model 8835), 326 U1 AS/ES v2.6.9−11.EL13 PCI−X FC−SW CLARiiON
(Model 8848) IBM 24P0960 (QLA2340)6, 11, 12, 14 ; AX150
QLogic QLA2340−E−SP6, 11, 12
24 IBM eServer 326m Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP1050Ex−E6, 8, 23, 51 , LPe111−E4, 6, 8, 51, LPe1150−E6, 8, 24, FC−AL, EMC Y2, 3
(Model 7969) U2 AS/ES v2.6.9−22.EL, U2+ Express, 51; FC−SW CLARiiON
AS/ES v2.6.9−22.0.1.EL, U2+ PCI−X AX150
AS/ES v2.6.9−22.0.2.EL QLogic: QLE2360−E−SP6, 30, 31, 52 , QLE2460−E−SP6, 25, 52
25 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: PCI−X Emulex: LP1050−E6, 8, 17, 51 , LP982−E6, 8, 51; FC−AL, EMC Y2, 3
x4100, x4200 U2 AS/ES v2.6.9−22.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.1.EL, U2+ QLogic QLA2340−E−SP6, 11, 52 AX150
AS/ES v2.6.9−22.0.2.EL
26 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: PCI−X QLogic QLA2460−E−SP6, 25, 52 FC−AL, EMC Y2, 3
U2 AS/ES v2.6.9−22.EL, U2+ FC−SW CLARiiON
AS/ES v2.6.9−22.0.1.EL, U2+ AX150
AS/ES v2.6.9−22.0.2.EL
27 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP101−E6, 8, 16, 23 , LP101−E6, 8, 23, 60 , LP1050−E8, 16, 17, FC−AL, EMC Y2, 3
DL14528, DL38528, U2 AS/ES v2.6.9−22.EL, U2+ PCI−X LP1050−E8, 17, 61, LP982−E8, 16, LP982−E8, 61; FC−SW CLARiiON
DL58528 AS/ES v2.6.9−22.0.1.EL, U2+ AX150
AS/ES v2.6.9−22.0.2.EL QLogic: QLA200−E−SP6, 9, QLA210−E−SP6, 9, 52
28 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP1050−E6, 8, 17, 51 , LP982−E6, 8, 51; FC−AL, EMC Y2, 3
(Model 8835), 326 U2 AS/ES v2.6.9−22.EL, U2+ PCI−X FC−SW CLARiiON
(Model 8848) AS/ES v2.6.9−22.0.1.EL, U2+ IBM 24P0960 (QLA2340)6, 11, 14, 52 AX150
AS/ES v2.6.9−22.0.2.EL
29 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: PCI, QLogic QLA2340−E−SP11, 52 FC−AL, EMC Y2, 3
Primergy RX800 S2; U2 AS/ES v2.6.9−22.EL, U2+ PCI−X FC−SW CLARiiON
HPQ Proliant: AS/ES v2.6.9−22.0.1.EL, U2+ AX150
DL14528, DL38528, AS/ES v2.6.9−22.0.2.EL
DL58528
30 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: PCI, QLogic QLA2340−E−SP6, 11, 52 FC−AL, EMC Y2, 3
Primergy RX800 S2; U2 AS/ES v2.6.9−22.EL, U2+ PCI−X FC−SW CLARiiON
IBM eServer: 325 AS/ES v2.6.9−22.0.1.EL, U2+ AX150
(Model 8835), 326 AS/ES v2.6.9−22.0.2.EL
(Model 8848)
31 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP101−E6, 7, 8, 23, LP1050−E6, 7, 8, 17, LP982−E6, 7, 8; FC−AL, EMC Y
U3 AS/ES v2.6.9−34.EL, U3+ Express, FC−SW CLARiiON
AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X QLogic: QLA200−E−SP6, 9, 10, QLA210−E−SP6, 9, 10, AX150
AS/ES v2.6.9−34.0.2.EL QLA2340−E−SP6, 10, 11, QLE220−E−SP6, 26, 27
32 Dell PowerEdge 6950; Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP1050Ex−E6, 7, 8, 23, LPe111−E4, 6, 7, 8, LPe1150−E6, 7, 8, 24; FC−AL, EMC Y
IBM eServer 326m U3 AS/ES v2.6.9−34.EL, U3+ Express, FC−SW CLARiiON
(Model 7969) AS/ES v2.6.9−34.0.1.EL, U3+ PCI−X QLogic: QLE2360−E−SP6, 10, 30, 31 , QLE2460−E−SP6, 10, 25 AX150
AS/ES v2.6.9−34.0.2.EL
33 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: PCI−X Emulex: LP1050−E6, 7, 8, 17, LP982−E6, 7, 8; FC−AL, EMC Y
x4100, x4200 U3 AS/ES v2.6.9−34.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.1.EL, U3+ QLogic QLA2340−E−SP6, 10, 11 AX150
AS/ES v2.6.9−34.0.2.EL
34 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: PCI−X QLogic QLA2460−E−SP6, 10, 25 FC−AL, EMC Y
U3 AS/ES v2.6.9−34.EL, U3+ FC−SW CLARiiON
AS/ES v2.6.9−34.0.1.EL, U3+ AX150
AS/ES v2.6.9−34.0.2.EL
35 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP101−E6, 7, 8, 23, LP1050−E7, 8, 17, LP982−E7, 8; FC−AL, EMC Y
DL14528, DL38528, U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
DL58528 AS/ES v2.6.9−34.0.1.EL, U3+ QLogic: QLA200−E−SP6, 9, 10, QLA210−E−SP6, 9, 10, QLE220−E−SP6, AX150
AS/ES v2.6.9−34.0.2.EL 26, 27, 29

36 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP1050−E6, 7, 8, 17, LP982−E6, 7, 8; FC−AL, EMC Y
(Model 8835), 326 U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
(Model 8848) AS/ES v2.6.9−34.0.1.EL, U3+ IBM 24P0960 (QLA2340)6, 10, 11, 14 AX150
AS/ES v2.6.9−34.0.2.EL
37 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: PCI, QLogic QLA2340−E−SP6, 10, 11 FC−AL, EMC Y
Primergy RX800 S2; U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
IBM eServer: 325 AS/ES v2.6.9−34.0.1.EL, U3+ AX150
(Model 8835), 326 AS/ES v2.6.9−34.0.2.EL
(Model 8848)
38 Fujitsu Siemens Red Hat RHEL [AMD−64] 4.0: PCI, QLogic QLA2340−E−SP10, 11 FC−AL, EMC Y
Primergy RX800 S2; U3 AS/ES v2.6.9−34.EL, U3+ PCI−X FC−SW CLARiiON
HPQ Proliant: AS/ES v2.6.9−34.0.1.EL, U3+ AX150
DL14528, DL38528, AS/ES v2.6.9−34.0.2.EL
DL58528
39 IBM xSeries x3455 Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP10000ExDC−E1, 6, 8, 59, LP1050Ex−E1, 6, 8, 23; FC−AL, EMC Y
(7984) U4 AS/ES v2.6.9−42.EL, U4+ Express FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL IBM: 42C2069 (LPe11000)1, 6, 8, 55, 42C2071 (LPe11002)1, 6, 8, 24; AX150
QLogic: QLE2360−E−SP6, 35, 50, QLE2460−E−SP6, 35, 49
40 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y2, 3
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403621−B21)1, 4, 5 FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL AX150
(407234−B21),
(407235−B21)
41 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y45
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403621−B21)1, 5, 46 FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL AX150
(407234−B21),
(407235−B21)
42 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403619−B21)34, 35 FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL AX150
(407234−B21),
(407235−B21)

11/02/2006 321 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
43 HPQ Proliant BL465c: Red Hat RHEL [AMD−64] 4.0: PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC Y
(403433−B21), U4 AS/ES v2.6.9−42.EL, U4+ Express (403621−B21)1, 5, 46, QLogic QMH2462 4Gb FC HBA for HP c−Class FC−SW CLARiiON
(403434−B21), AS/ES v2.6.9−42.0.2.EL Bladesystem (403619−B21)34, 35 AX150
(407234−B21),
(407235−B21)
44 Dell PowerEdge 6950; Red Hat RHEL [AMD−64] 4.0: PCI Emulex LP1050−E1, 6, 8, 17; FC−AL, EMC Y
IBM xSeries x3755 U4 AS/ES v2.6.9−42.EL, U4+ Express, QLogic QLA2340−E−SP6, 11, 35 FC−SW CLARiiON
(8877) AS/ES v2.6.9−42.0.2.EL PCI−X AX150
45 Dell PowerEdge 6950 Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP101−E1, 6, 8, 23, LP982−E1, 6, 8; FC−AL, EMC Y
U4 AS/ES v2.6.9−42.EL, U4+ Express, FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLA200−E−SP6, 9, 35, QLA210−E−SP6, 9, 35, QLE220−E−SP6, AX150
27, 44

46 Dell PowerEdge 6950; Red Hat RHEL [AMD−64] 4.0: PCI Emulex: LP1050Ex−E1, 6, 8, 23, LPe111−E1, 4, 6, 8, LPe1150−E1, 6, 8, 24; FC−AL, EMC Y
IBM eServer 326m U4 AS/ES v2.6.9−42.EL, U4+ Express, FC−SW CLARiiON
(Model 7969) AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLE2360−E−SP6, 30, 31, 35 , QLE2460−E−SP6, 25, 35 AX150
47 IBM xSeries x3755 Red Hat RHEL [AMD−64] 4.0: PCI IBM: 24P0960 (QLA2340)6, 11, 14, 35 , 24P8053 (QLA2342)6, 11, 35; FC−AL, EMC Y
(8877) U4 AS/ES v2.6.9−42.EL, U4+ Express, FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL PCI−X QLogic: QLA2460−E−SP6, 35, 49, QLE2360−E−SP6, 35, 50, AX150
QLE2460−E−SP6, 35, 49
48 Sun: V20z, V40z, Red Hat RHEL [AMD−64] 4.0: PCI−X Emulex: LP1050−E1, 6, 8, 17, LP982−E1, 6, 8; FC−AL, EMC Y
x4100, x4200 U4 AS/ES v2.6.9−42.EL, U4+ FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL QLogic QLA2340−E−SP6, 11, 35 AX150
49 Sun: x4100, x4200 Red Hat RHEL [AMD−64] 4.0: PCI−X QLogic QLA2460−E−SP6, 25, 35 FC−AL, EMC Y
U4 AS/ES v2.6.9−42.EL, U4+ FC−SW CLARiiON
AS/ES v2.6.9−42.0.2.EL AX150
50 HPQ Proliant: Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP101−E1, 6, 8, 23, LP1050−E1, 8, 17, LP982−E1, 8; FC−AL, EMC Y
DL14528, DL38528, U4 AS/ES v2.6.9−42.EL, U4+ PCI−X FC−SW CLARiiON
DL58528 AS/ES v2.6.9−42.0.2.EL QLogic: QLA200−E−SP6, 9, 35, QLA210−E−SP6, 9, 35, AX150
QLA2340−E−SP11, 35, QLE220−E−SP6, 27, 29, 44
51 IBM eServer: 325 Red Hat RHEL [AMD−64] 4.0: PCI, Emulex: LP1050−E1, 6, 8, 17, LP982−E1, 6, 8; FC−AL, EMC Y
(Model 8835), 326 U4 AS/ES v2.6.9−42.EL, U4+ PCI−X FC−SW CLARiiON
(Model 8848) AS/ES v2.6.9−42.0.2.EL IBM 24P0960 (QLA2340)6, 11, 14, 35 ; AX150
QLogic QLA2340−E−SP6, 11, 35
52 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0 PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)6, 33, 36, 38 , FC−SW EMC Y
LS20 (Model 8850) U7 AS/ES v2.4.21−40.EL21, 32 LP1005DC FC Exp Card6, 8, 33, 39 ; CLARiiON
AX150
IBM HS20 4GB SFF FC Exp Card: (26R0890)6, 43, 48, (26R0890)6, 48;
IBM HS20: 4GB Standard FC Exp Card (26R0884)6, 43, 47, FC Exp
Card (13N2203) for IBM eServer LS206, 11, 43, FC SFF Exp Card
(26K4841) for IBM eServer LS206, 11, 43
53 IBM BladeCenter: Red Hat RHEL [AMD−64] 3.0 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)6, 36, 37, 38 , FC−SW EMC Y
LS20 (Model 8850), U8 AS/ES v2.4.21−47.EL21, 32 HS20 4GB SFF FC Exp Card (26R0890)6, 40, 48, HS20 FC Exp Card CLARiiON
LS21 (Model 7971), (26K4841)6, 11, 40 AX150
LS41 (Model 7972)
54 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0 PCI−X IBM: Emulex LP1005DC FC Exp Card6, 8, 37, 39 , HS20 4GB Standard FC−SW EMC Y
LS20 (Model 8850) U8 AS/ES v2.4.21−47.EL21, 32 FC Exp Card (26R0884)6, 40, 47, HS20 FC Exp Card (13N2203) for IBM CLARiiON
eServer LS206, 11, 40, HS20 FC SFF Exp Card (26K4841) for IBM AX150
eServer LS206, 11, 40
55 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0: PCI−X IBM HS20 4GB SFF FC Exp Card: (26R0890)6, 43, 48, (26R0890)6, 48; FC−SW EMC N3, 15
LS20 (Model 8850) U6 AS/ES v2.4.21−37.EL, U6+ CLARiiON
AS/ES v2.4.21−37.0.1.EL IBM HS20 4GB Standard FC Exp Card (26R0884)6, 43, 47 AX150
56 IBM BladeCenter Red Hat RHEL [AMD−64] 3.0: PCI−X IBM: Emulex LP1005DC FC Exp Card6, 8, 39, 56 , HS20 FC Exp Card FC−SW EMC Y3, 15
LS20 (Model 8850) U6 AS/ES v2.4.21−37.EL, U6+ (13N2203) for IBM eServer LS206, 11, 43, HS20 FC SFF Exp Card CLARiiON
AS/ES v2.4.21−37.0.1.EL (26K4841) for IBM eServer LS206, 11, 43 AX150
57 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: PCI−X IBM: Emulex LP1005DC FC Exp Card6, 8, 39, 51 , HS20 4GB SFF FC FC−SW EMC Y2, 3
LS20 (Model 8850) U2 AS/ES v2.6.9−22.EL, U2+ Exp Card (26R0890)6, 48, HS20 4GB Standard FC Exp Card CLARiiON
AS/ES v2.6.9−22.0.1.EL, U2+ (26R0884)6, 47, 52, HS20 FC Exp Card (13N2203) for IBM eServer AX150
AS/ES v2.6.9−22.0.2.EL LS206, 11, 52, HS20 FC SFF Exp Card (26K4841) for IBM eServer
LS206, 11, 52
58 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)6, 7, 36, 38 , FC−SW EMC Y
LS20 (Model 8850) U3 AS/ES v2.6.9−34.EL, U3+ LP1005DC FC Exp Card6, 7, 8, 39; CLARiiON
AS/ES v2.6.9−34.0.1.EL, U3+ AX150
AS/ES v2.6.9−34.0.2.EL IBM HS20 4GB: SFF FC Exp Card (26R0890)6, 10, 48, Standard FC Exp
Card (26R0884)6, 10, 47;
IBM HS20 FC: Exp Card (13N2203) for IBM eServer LS206, 10, 11, SFF
Exp Card (26K4841) for IBM eServer LS206, 10, 11
59 IBM BladeCenter Red Hat RHEL [AMD−64] 4.0: PCI−X IBM Emulex: 4Gb SFF Fibre Channel Exp Card (39Y9186)1, 6, 36, 38 , FC−SW EMC Y
LS20 (Model 8850) U4 AS/ES v2.6.9−42.EL, U4+ LP1005DC FC Exp Card1, 6, 8, 39; CLARiiON
AS/ES v2.6.9−42.0.2.EL AX150
IBM HS20 4GB: SFF FC Exp Card (26R0890)6, 35, 48, Standard FC Exp
Card (26R0884)6, 35, 47;
IBM HS20 FC Exp Card: (13N2203) for IBM eServer LS206, 11, 35,
(26K4841)6, 11, 35;
IBM HS20 FC SFF Exp Card (26K4841) for IBM eServer LS206, 11, 35
1. Driver Version 8.0.16.27 Driver is integrated into the kernel.
2. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
3. VxVM is not supported on servers booting from the array.
4. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
6. SNIA HBA API Supported.
7. Driver Version 8.0.16.18 Driver is integrated into the kernel.
8. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
9. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
11. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
14. This HBA is equivalent to the QLogic QLA2340.
15. Booting from the SAN with PowerPath is not supported.
16. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
17. Firmware Version 1.91a5
18. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

11/02/2006 322 CLARiiON AX150


CLARiiON AX150

19. Driver Version 7.03.00 QLogic driver obtained from http://www.qlogic.com


20. Driver Version 7.01.01 Driver is integrated into the kernel.
21. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
22. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file names
must be used.
23. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. Firmware Version 2.50a6
25. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
27. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
28. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
29. Driver/BIOS are available at http://www.qlogic.com
30. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
31. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
32. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
33. Driver Version 7.3.3 Driver is integrated into the kernel.
34. BIOS 1.16
35. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
36. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
37. Driver Version 7.3.6 Driver is integrated into the kernel.
38. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
39. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
40. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
41. Firmware Version 1.91a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. FCode Value 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
43. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
44. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
45. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
46. Firmware Version 2.50a8
47. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
48. BIOS 1.12
49. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
50. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
51. Driver Version 8.0.16.17 Driver is integrated into the kernel.
52. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
53. BIOS 1.02
54. Driver Version 7.07.05
55. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
56. Driver Version 7.3.2 Driver is integrated into the kernel.
57. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
58. PowerPath is not supported.
59. Firmware Version 1.91.a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
60. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
61. Driver Version 8.0.16.6_x2−2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com The Emulex 8.0.16.6_x2−2 package supersedes the Emulex
8.0.16.6_x2−1 package.
62. Driver Version 7.07.00

Red Hat RHEL [EM64T]

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 39 ; FC−AL, EMC Y
1850, 1950, 2800, 2850; v2.4.21−40.EL18, 19 Express QLogic QLE2360−E−SP4, 21, 40, 41 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
2 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI Emulex: LPe111−E1, 4, 37, 39 , LPe1150−E1, 3, 4, 39 FC−AL, EMC Y
1850, 1950, 2800, 2850; v2.4.21−40.EL18, 19 Express FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230

11/02/2006 323 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
3 HPQ Proliant: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 4, 14, 39 FC−AL, EMC Y
DL360(G4)28, v2.4.21−40.EL18, 19 Express FC−SW CLARiiON
DL380(G4)28, AX150
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
4 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI QLogic QLE2460−E−SP4, 5, 21 FC−AL, EMC Y
1850, 1950, 2800, 2850; v2.4.21−40.EL18, 19 Express FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
5 IBM xSeries: x3550 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI Emulex LP1050−E1, 4, 31, 39 ; FC−AL, EMC Y52
(7978), x3650 (7979) v2.4.21−40.EL18, 19 Express, IBM: 24P0960 (QLA2340)4, 12, 21, 55 , 24P8053 FC−SW CLARiiON
PCI−X (QLA2342)4, 12, 21, 39M5894 (QLA2460)4, 5, 21, AX150
39M5895 (QLA2462)4, 5, 21;
QLogic: QLA2340−E−SP4, 12, 21,
QLA2460−E−SP4, 5, 21, QLE2360−E−SP4, 21, 40,
QLE2460−E−SP4, 5, 21
6 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI Emulex: LP101−E1, 4, 10, 39 , LP1050−E1, 4, 31, 39 , FC−AL, EMC Y
2950; v2.4.21−40.EL18, 19 Express, LP1050Ex−E1, 4, 10, 39 , LP982−E1, 4, 39, FC−SW CLARiiON
PCI−X LPe111−E1, 4, 37, 39 , LPe1150−E1, 3, 4, 39; AX150
Digital Henge Revo:
AS1500, AS1550, QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
AS2500; 20, 21, QLA2340−E−SP4, 12, 21, QLE2360−E−SP4,
21, 40, 41 , QLE2460−E−SP4, 5, 21
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
7 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X Dell 2342M12, 21 FC−AL, EMC Y
Unisys ES3105 v2.4.21−40.EL18, 19 FC−SW CLARiiON
AX150
8 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X Dell: LPe1105−M1, 3, 4, 39, QME24624, 21, 46 FC−AL, EMC Y
v2.4.21−40.EL18, 19 FC−SW CLARiiON
AX150
9 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X Emulex LP982−E1, 4, 39 FC−AL, EMC Y
1850, 2600, 2650, 2850; v2.4.21−40.EL18, 19 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
10 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 39 , LP1050−E1, 4, 31, 39 ; FC−AL, EMC Y
1850, 1950, 2600, 2650, v2.4.21−40.EL18, 19 FC−SW CLARiiON
2850; QLogic: QLA200−E−SP4, 20, 57, QLA2340−E−SP4, AX150
12, 21
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
11 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y16, 17
(416653−B21), v2.4.21−40.EL18, 19 c−Class Bladesystem (403621−B21)37, 39, 69 FC−SW CLARiiON
(416654−B21), AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)

11/02/2006 324 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
12 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−AL, EMC N
(416653−B21), v2.4.21−40.EL18, 19 c−Class Bladesystem (403619−B21)21, 68 FC−SW CLARiiON
(416654−B21), AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
13 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X NEC N8190−120 (LP1050)1, 10, 11, 39 FC−AL, EMC Y
120Lh, 120Re−1, v2.4.21−40.EL18, 19 FC−SW CLARiiON
120Rf−1, 120Rg−2, AX150
120Rh−2, 140He,
140Rd−4
14 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 11, 14, 39 FC−AL, EMC Y
140He, 140Rd−4 v2.4.21−40.EL18, 19 FC−SW CLARiiON
AX150
15 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X QLogic QLA210−E−SP4, 20, 21 FC−AL, EMC Y
1850, 2600, 2650, 2850; v2.4.21−40.EL18, 19 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
16 Digital Henge INNO: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X QLogic QLE220−E−SP4, 27, 62, 63 FC−AL, EMC Y
HR−4850, HR−6850; v2.4.21−40.EL18, 19 FC−SW CLARiiON
AX150
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
17 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X22 Emulex: LP101−E1, 4, 10, 39 , LP1050−E1, 4, 31, 39 , FC−AL, EMC Y
JS1400, JS2400 v2.4.21−40.EL18, 19 LP982−E1, 4, 39; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21, QLA2340−E−SP4, 12, 21, QLE220−E−SP4,
27, 62, 63

18 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X23 QLogic: QLA210−E−SP4, 20, 21, QLE220−E−SP4, FC−AL, EMC Y
(8865)24, 25, v2.4.21−40.EL18, 19 27, 62, 63 FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25
19 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 39, QME24624, 21, 46 FC−AL, EMC Y
v2.4.21−40.EL18, 19 Express, FC−SW CLARiiON
PCI−X AX150
20 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, Emulex: LP101−E1, 4, 10, 39 , LP1050−E1, 4, 31, 39 , FC−AL, EMC Y
Samsung: ES470, ES570, v2.4.21−40.EL18, 19 PCI−X LP982−E1, 4, 39; FC−SW CLARiiON
SS140 AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21

21 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 21 FC−AL, EMC Y
Samsung: ES570, SS140 v2.4.21−40.EL18, 19 PCI−X FC−SW CLARiiON
AX150
22 Samsung ES470 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 57 FC−AL, EMC Y
v2.4.21−40.EL18, 19 PCI−X FC−SW CLARiiON
AX150
23 Samsung: ES470, ES570, Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI, QLogic QLE220−E−SP4, 27, 62, 63 FC−AL, EMC Y
SS140 v2.4.21−40.EL18, 19 PCI−X FC−SW CLARiiON
AX150

11/02/2006 325 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
24 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 36 ; FC−AL, EMC Y
1850, 1950, 2800, 2850; v2.4.21−47.EL18, 19 Express QLogic QLE2360−E−SP4, 40, 56 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
25 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI Emulex: LPe111−E1, 4, 36, 37 , LPe1150−E1, 3, 4, 36 FC−AL, EMC Y
1850, 1950, 2800, 2850; v2.4.21−47.EL18, 19 Express FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
26 HPQ Proliant: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 4, 14, 36 FC−AL, EMC Y
DL360(G4)28, v2.4.21−47.EL18, 19 Express FC−SW CLARiiON
DL380(G4)28, AX150
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
27 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI QLogic QLE2460−E−SP4, 5, 56 FC−AL, EMC Y
1850, 1950, 2800, 2850; v2.4.21−47.EL18, 19 Express FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
28 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI Emulex: LP101−E1, 4, 10, 36 , LP1050−E1, 4, 31, 36 , FC−AL, EMC Y
2950; v2.4.21−47.EL18, 19 Express, LP1050Ex−E1, 4, 10, 36 , LP982−E1, 4, 36, FC−SW CLARiiON
PCI−X LPe111−E1, 4, 36, 37 , LPe1150−E1, 3, 4, 36; AX150
Digital Henge Revo:
AS1500, AS1550, QLogic: QLA200−E−SP4, 20, 56, QLA210−E−SP4,
AS2500; 20, 56, QLA2340−E−SP4, 12, 56, QLE2360−E−SP4,
40, 56, QLE2460−E−SP4, 5, 56
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
29 IBM xSeries: x3550 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI Emulex: LP1050−E1, 4, 31, 36 , LP1050Ex−E1, 4, 10, FC−AL, EMC Y52
(7978), x3650 (7979) v2.4.21−47.EL18, 19 Express, 36; FC−SW CLARiiON
PCI−X AX150
IBM: 24P0960 (QLA2340)4, 12, 55, 56 , 24P8053
(QLA2342)4, 12, 56, 39M5894 (QLA2460)4, 5, 56,
39M5895 (QLA2462)4, 5, 56;
QLogic: QLA2340−E−SP4, 12, 56,
QLA2460−E−SP4, 5, 56, QLE2360−E−SP4, 40, 56,
QLE2460−E−SP4, 5, 56
30 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI NEC: N8190−120 (LP1050)11, 31, 36, 61 , FC−AL, EMC Y
120Li, 120Rg−1, 120Ri−2, v2.4.21−47.EL18, 19 Express, N8190−127 (LPe1150)3, 11, 36, 61 FC−SW CLARiiON
140Hf, 140Re−4 PCI−X AX150
31 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X Dell 2342M12, 56 FC−AL, EMC Y
Unisys ES3105 v2.4.21−47.EL18, 19 FC−SW CLARiiON
AX150
32 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X Dell: LPe1105−M1, 3, 4, 36, QME24624, 46, 56 FC−AL, EMC Y
v2.4.21−47.EL18, 19 FC−SW CLARiiON
AX150

11/02/2006 326 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
33 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X Emulex LP982−E1, 4, 36 FC−AL, EMC Y
1850, 2600, 2650, 2850; v2.4.21−47.EL18, 19 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
34 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 36 , LP1050−E1, 4, 31, 36 ; FC−AL, EMC Y
1850, 1950, 2600, 2650, v2.4.21−47.EL18, 19 FC−SW CLARiiON
2850; QLogic: QLA200−E−SP4, 20, 56, QLA2340−E−SP4, AX150
12, 56
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
35 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y16, 17
(416653−B21), v2.4.21−47.EL18, 19 c−Class Bladesystem (403621−B21)36, 37, 69 FC−SW CLARiiON
(416654−B21), AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
36 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−AL, EMC N
(416653−B21), v2.4.21−47.EL18, 19 c−Class Bladesystem (403619−B21)56, 68 FC−SW CLARiiON
(416654−B21), AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
37 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X NEC N8190−120 (LP1050)1, 10, 11, 36 FC−AL, EMC Y
120Lh, 120Re−1, v2.4.21−47.EL18, 19 FC−SW CLARiiON
120Rf−1, 120Rg−2, AX150
120Rh−2, 140He,
140Rd−4
38 NEC Express 5800: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 11, 14, 36 FC−AL, EMC Y
140He, 140Rd−4 v2.4.21−47.EL18, 19 FC−SW CLARiiON
AX150
39 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X QLogic QLA210−E−SP4, 20, 56 FC−AL, EMC Y
1850, 2600, 2650, 2850; v2.4.21−47.EL18, 19 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230

11/02/2006 327 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
40 Digital Henge INNO: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X QLogic QLE220−E−SP4, 62, 63 FC−AL, EMC Y
HR−4850, HR−6850; v2.4.21−47.EL18, 19 FC−SW CLARiiON
AX150
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
41 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X22 Emulex: LP101−E1, 4, 10, 36 , LP1050−E1, 4, 31, 36 , FC−AL, EMC Y
JS1400, JS2400 v2.4.21−47.EL18, 19 LP982−E1, 4, 36; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP4, 20, 56, QLA210−E−SP4,
20, 56, QLA2340−E−SP4, 12, 56, QLE220−E−SP4,
62, 63

42 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X23 QLogic: QLA210−E−SP4, 20, 56, QLE220−E−SP4, FC−AL, EMC Y
(8865)24, 25, v2.4.21−47.EL18, 19 62, 63 FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25
43 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 36, QME24624, 46, 56 FC−AL, EMC Y
v2.4.21−47.EL18, 19 Express, FC−SW CLARiiON
PCI−X AX150
44 HPQ Proliant: DL380(G5), Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, PCI Emulex: LPe111−E1, 4, 36, 37 , LPe1150−E1, 3, 4, 36; FC−AL, EMC Y
DL580(G4) v2.4.21−47.EL18, 19 Express, FC−SW CLARiiON
PCI−X HPQ: A8002A/FC2142SR (LPe1150)1, 4, 14, 36 , AX150
AE311A/FC1142SR (QLE2460)4, 5, 56,
AE312A/FC1242SR (QLE2462)4, 5, 56
45 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, Emulex: LP101−E1, 4, 10, 36 , LP1050−E1, 4, 31, 36 , FC−AL, EMC Y
Samsung: ES470, ES570, v2.4.21−47.EL18, 19 PCI−X LP982−E1, 4, 36; FC−SW CLARiiON
SS140 AX150
QLogic: QLA200−E−SP4, 20, 56, QLA210−E−SP4,
20, 56, QLA2340−E−SP4, 12, 56

46 Samsung: ES470, ES570, Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI, QLogic QLE220−E−SP4, 62, 63 FC−AL, EMC Y
SS140 v2.4.21−47.EL18, 19 PCI−X FC−SW CLARiiON
AX150
47 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI NEC N8190−120: (LP1050)1, 10, 11, 81 , (LP1050)1, FC−AL, EMC N17, 45
120Rd−1, 140Hd, v2.4.21−32.EL18, 73, U5+ AS/ES 10, 11, 82, 83 FC−SW CLARiiON
140Rc−4, 180Rd−4 v2.4.21−32.0.1.EL18, 73 AX150
48 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 47 ; FC−AL, EMC Y17, 45
1850, 2800, 2850; v2.4.21−32.EL18, 73, U5+ AS/ES Express QLogic QLE2360−E−SP4, 21, 40, 41 FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
49 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI Emulex: LP101−E1, 4, 10, 76 , LP1050−E1, 4, 31, 76 ; FC−AL, EMC Y17, 45
1850, 2800, 2850; v2.4.21−32.EL18, 73, U5+ AS/ES Express, FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 PCI−X QLogic QLA200−E−SP4, 20, 74, 75 AX150
LangChao: NC3000,
NC3500, NF500, NF520
50 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X Dell 2342M12, 80 FC−AL, EMC N17, 45
v2.4.21−32.EL18, 73, U5+ AS/ES FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 AX150
51 Dell PowerEdge: 2600, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 76 , LP1050−E1, 4, 31, 76 ; FC−AL, EMC Y17, 45
2650; v2.4.21−32.EL18, 73, U5+ AS/ES FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 QLogic QLA200−E−SP4, 20, 74, 75 AX150
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NF420;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS370,
SS3840, ZSS150,
ZSS230

11/02/2006 328 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
52 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X NEC N8190−120: (LP1050)1, 10, 11, 81 , (LP1050)1, FC−AL, EMC N17, 45
120Lh, 120Re−1, v2.4.21−32.EL18, 73, U5+ AS/ES 10, 11, 82, 83 FC−SW CLARiiON
120Rf−1, 120Rg−2, v2.4.21−32.0.1.EL18, 73 AX150
120Rh−2
53 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X23 Emulex: LP101−E1, 4, 10, 76 , LP1050−E1, 4, 31, 76 ; FC−AL, EMC Y17, 45
(8865)24, 25, v2.4.21−32.EL18, 73, U5+ AS/ES FC−SW CLARiiON
x3950/x3950E/x460 v2.4.21−32.0.1.EL18, 73 QLogic QLA200−E−SP4, 20, 74, 75 AX150
(8872, 8874)24, 25
54 Samsung: ES470, ES570, Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI, Emulex: LP101−E1, 4, 10, 76 , LP1050−E1, 4, 31, 76 ; FC−AL, EMC Y17, 45
SS140 v2.4.21−32.EL18, 73, U5+ AS/ES PCI−X FC−SW CLARiiON
v2.4.21−32.0.1.EL18, 73 QLogic QLA200−E−SP4, 20, 74, 75 AX150
55 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 47 ; FC−AL, EMC Y17, 45
1850, 1950, 2800, 2850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express QLogic QLE2360−E−SP4, 21, 40, 41 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
56 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI Emulex: LPe111−E1, 4, 37, 47 , LPe1150−E1, 3, 4, 47 FC−AL, EMC Y17, 45
1850, 1950, 2800, 2850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
57 HPQ Proliant: Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 4, 14, 47 FC−AL, EMC Y17, 45
DL360(G4)28, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express FC−SW CLARiiON
DL380(G4)28, AX150
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
58 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI QLogic QLE2460−E−SP4, 5, 21 FC−AL, EMC Y17, 45
1850, 1950, 2800, 2850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
59 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 , FC−AL, EMC Y17, 45
2950 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, LP1050Ex−E1, 4, 10, 47 , LP982−E1, 4, 47, FC−SW CLARiiON
PCI−X LPe111−E1, 4, 37, 47 , LPe1150−E1, 3, 4, 47; AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21, QLA2340−E−SP4, 12, 21, QLE2360−E−SP4,
21, 40, 41 , QLE2460−E−SP4, 5, 21

60 Dell PowerEdge 1855; Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X Dell 2342M12, 21 FC−AL, EMC N17, 45
Unisys ES3105 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX150
61 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X Dell: LPe1105−M1, 3, 4, 47, QME24624, 21, 46 FC−AL, EMC N17, 45
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
AX150

11/02/2006 329 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
62 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X Emulex LP982−E1, 4, 47; FC−AL, EMC Y17, 45
1850, 2600, 2650, 2850; v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL QLogic QLA210−E−SP4, 20, 21 FC−SW CLARiiON
AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
63 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 ; FC−AL, EMC Y17, 45
1850, 1950, 2600, 2650, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
2850; QLogic: QLA200−E−SP4, 20, 57, QLA2340−E−SP4, AX150
12, 21
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
ZSS150, ZSS230
64 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X NEC N8190−120 (LP1050)1, 10, 11, 71 FC−AL, EMC N17, 45
120Lh, 120Re−1, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL FC−SW CLARiiON
120Rf−1, 120Rg−2, AX150
120Rh−2
65 NEC Express 5800: Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X NEC: N8190−120 (LP1050)1, 10, 11, 47 , FC−AL, EMC N17, 45
140He, 140Rd−4 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL N8190−127 (LPe1150)1, 11, 14, 47 FC−SW CLARiiON
AX150
66 Digital Henge Revo: Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X22 Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 , FC−AL, EMC Y17, 45
JS1400, JS2400 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP982−E1, 4, 47; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21, QLA2340−E−SP4, 12, 21

67 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X23 Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 , FC−AL, EMC Y17, 45
(8865)24, 25, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL LP982−E1, 4, 47; FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25 QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21, QLA2340−E−SP4, 12, 21

68 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 47, QME24624, 21, 46 FC−AL, EMC N17, 45
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL Express, FC−SW CLARiiON
PCI−X AX150
69 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, Emulex: LP101−E1, 4, 10, 47 , LP1050−E1, 4, 31, 47 , FC−AL, EMC Y17, 45
Samsung: ES470, ES570, v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X LP982−E1, 4, 47; FC−SW CLARiiON
SS140 AX150
QLogic: QLA200−E−SP4, 20, 57, QLA210−E−SP4,
20, 21

70 Dell PowerEdge 2800; Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 21 FC−AL, EMC Y17, 45
Samsung: ES570, SS140 v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX150
71 Samsung ES470 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI, QLogic QLA2340−E−SP4, 12, 57 FC−AL, EMC Y17, 45
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL PCI−X FC−SW CLARiiON
AX150
72 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP4, 30, 42 FC−AL, EMC Y
v2.4.21−40.EL18, 19, U8 AS/ES Express FC−SW CLARiiON
v2.4.21−47.EL18, 19 AX150
73 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI QLogic QLE220−E−SP4, 30, 42 FC−AL, EMC Y
1900, 2850, 2900, 2950; v2.4.21−40.EL18, 19, U8 AS/ES Express, FC−SW CLARiiON
v2.4.21−47.EL18, 19 PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
74 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 3.0: U7 AS/ES PCI, PCI QLogic QLE220−E−SP4, 30, 42 FC−AL, EMC Y
2800 v2.4.21−40.EL18, 19, U8 AS/ES Express, FC−SW CLARiiON
v2.4.21−47.EL18, 19 PCI−X AX150

11/02/2006 330 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
75 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 72 ; FC−AL, EMC Y17, 45
1850, 2800, 2850, 6800, v2.6.9−11.EL44 Express QLogic QLE2360−E−SP4, 40, 41, 43 FC−SW CLARiiON
6850; AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
76 Dell PowerEdge 2850 Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI QLogic QLA200−E−SP4, 9, 20, 43 FC−AL, EMC Y17, 45
v2.6.9−11.EL44 Express FC−SW CLARiiON
AX150
77 HPQ Proliant Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 31, 72, FC−AL, EMC N17, 45
ML350(G4)28 v2.6.9−11.EL44 Express, LP982−E1, 72; FC−SW CLARiiON
PCI−X AX150
QLogic: QLA200−E−SP4, 20, 43,
QLA2340−E−SP12, 43
78 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X Dell 2342M12, 43 FC−AL, EMC N17, 45
v2.6.9−11.EL44 FC−SW CLARiiON
AX150
79 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X Emulex LP101−E1, 4, 59, 72 FC−AL, EMC N17, 45
RX200 S2, RX300, v2.6.9−11.EL44 FC−SW CLARiiON
RX300 S2, TX200 S2, AX150
TX300, TX300 S2
80 Dell PowerEdge: 6800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 4, 31, 72 , FC−AL, EMC Y17, 45
6850; v2.6.9−11.EL44 LP982−E1, 4, 72; FC−SW CLARiiON
AX150
Digital Henge INNO: QLogic QLA2340−E−SP4, 12, 43
HR−4850, HR−6850;
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
81 HPQ Proliant Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 31, 72, FC−AL, EMC N17, 45
DL360(G4)28 v2.6.9−11.EL44 LP982−E1, 72 FC−SW CLARiiON
AX150
82 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X QLogic: QLA200−E−SP4, 20, 43, FC−AL, EMC N17, 45
RX200 S2, RX300, v2.6.9−11.EL44 QLA2340−E−SP12, 43 FC−SW CLARiiON
RX300 S2, TX200 S2, AX150
TX300, TX300 S2;
HPQ Proliant
DL360(G4)28
83 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X22 Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 4, 31, 72 , FC−AL, EMC Y17, 45
JS1400, JS2400 v2.6.9−11.EL44 LP982−E1, 4, 72; FC−SW CLARiiON
AX150
QLogic QLA2340−E−SP4, 12, 43
84 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI−X23 Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 4, 31, 72 , FC−AL, EMC Y17, 45
(8865)24, 25, v2.6.9−11.EL44 LP982−E1, 4, 72; FC−SW CLARiiON
x3950/x3950E/x460 AX150
(8872, 8874)24, 25 QLogic QLA2340−E−SP4, 12, 43
85 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI, Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 4, 31, 72 , FC−AL, EMC Y17, 45
1850, 2600, 2650, 2800, v2.6.9−11.EL44 PCI−X LP982−E1, 4, 72; FC−SW CLARiiON
2850; AX150
QLogic QLA2340−E−SP4, 12, 43
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
86 HPQ Proliant: Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI, Emulex: LP101−E1, 4, 10, 72 , LP1050−E1, 31, 72, FC−AL, EMC N17, 45
DL380(G4)28, v2.6.9−11.EL44 PCI−X LP982−E1, 72; FC−SW CLARiiON
ML370(G4)28 AX150
QLogic: QLA200−E−SP4, 20, 43,
QLA2340−E−SP12, 43
87 Dell PowerEdge 2850 Red Hat RHEL [EM64T] 4.0 U1 AS/ES PCI, QLogic QLA200−E−SP4, 9, 20, 43 FC−AL, EMC Y17, 45
v2.6.9−11.EL44 PCI−X FC−SW CLARiiON
AX150

11/02/2006 331 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
88 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LP1050−E1, 4, 15, 59 ; FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Fujitsu Siemens BX600−FC22Q4, 12, 13 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
89 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LP101−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
2800, 2850, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express QLogic: QLA200−E−SP4, 20, 32, QLA210−E−SP4, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL 20, 32 AX150
Digital Henge Revo:
JS1400, JS2400
90 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
1850, 1950, 2800, 2850, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express QLogic QLE2360−E−SP4, 32, 40, 41 FC−SW CLARiiON
6800, 6850; U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
Lenovo SureServer:
R650, T650;
Samsung ZSS150
91 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LPe111−E1, 4, 15, 37 FC−AL, EMC Y16, 17
1850, 1950, 2800, 2850, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28;
Lenovo SureServer:
R650, T650;
Samsung ZSS150
92 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LPe1150−E1, 3, 4, 15 FC−AL, EMC Y16, 17
1850, 1950, 2800, 2850, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U2+ AS/ES v2.6.9−22.0.2.EL AX150
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
93 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LPe1150−E1, 3, 4, 67 FC−AL, EMC Y16, 17
JS1400, JS2400; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Lenovo SureServer:
R650, T650;
Samsung ZSS150
94 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 4, 15, 31 , LP982−E1, 4, 15; FC−AL, EMC Y16, 17
2800, 2850 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL QLogic QLA2340−E−SP4, 12, 32 AX150
95 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 4, 14, 15 FC−AL, EMC Y16, 17
DL360(G4)28, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
DL380(G4)28, U2+ AS/ES v2.6.9−22.0.2.EL AX150
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
96 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI QLogic QLE2460−E−SP4, 5, 32 FC−AL, EMC Y16, 17
1850, 1950, 2800, 2850, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge Revo:
JS1400, JS2400;
Lenovo SureServer:
R650, T650;
Samsung ZSS150
97 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LP101−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
2950, 6800, 6850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, QLogic: QLA200−E−SP4, 20, 32, QLA210−E−SP4, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X 20, 32 AX150
HPQ Proliant
ML350(G4)28
98 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 15, 31, LP982−E1, 15; FC−AL, EMC Y16, 17
ML350(G4)28 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 32, 33, AX150
AE369A/FC1243 (QLA2462)4, 32, 33;
QLogic QLA2340−E−SP12, 32
99 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP1050−E1, 4, 15, 31 , LP982−E1, 4, 15; FC−AL, EMC Y16, 17
2950, 6800, 6850 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X QLogic QLA2340−E−SP4, 12, 32 AX150
100 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP1050Ex−E1, 4, 10, 15 , LPe111−E1, 4, 15, FC−AL, EMC Y16, 17
2950 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, 37, LPe1150−E1, 3, 4, 15; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X AX150
QLogic: QLE2360−E−SP4, 32, 40, 41 ,
QLE2460−E−SP4, 5, 32

11/02/2006 332 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
101 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP101−E1, 4, 10, 15 , LP1050−E1, 15, 31, FC−AL, EMC Y16, 17
JS1400, JS2400 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, LP982−E1, 15; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X22 AX150
QLogic: QLA200−E−SP4, 20, 32, QLA210−E−SP4,
20, 32, QLA2340−E−SP12, 32

102 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Dell: 2342M12, 32, LPe1105−M1, 3, 4, 15, FC−AL, EMC Y16, 17
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QME24624, 32, 46 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
103 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
1950; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA200−E−SP4, 20, 32 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
104 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP1050−E1, 4, 15, 31 ; FC−AL, EMC Y16, 17
1950; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP4, 12, 32 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NF420;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150
105 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP982−E1, 4, 15 FC−AL, EMC Y16, 17
Digital Henge SH4500R4; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
IBM xSeries: x255, x336 U2+ AS/ES v2.6.9−22.0.2.EL AX150
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NF420;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150
106 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex: LP1050−E1, 15, 31, LP982−E1, 15; FC−AL, EMC Y16, 17
DL360(G4)28 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL HPQ: AB429A/FC1143 (QLA2460)4, 32, 33, AX150
AE369A/FC1243 (QLA2462)4, 32, 33
107 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X NEC N8190−120 (LP1050)1, 10, 11, 15 FC−AL, EMC Y16, 17
120Lh, 120Re−1, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
120Rf−1, 120Rg−2, U2+ AS/ES v2.6.9−22.0.2.EL AX150
120Rh−2, 140He,
140Rd−4
108 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 11, 14, 15 FC−AL, EMC Y16, 17
140He, 140Rd−4 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
109 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X QLogic QLA210−E−SP4, 20, 32 FC−AL, EMC Y16, 17
Digital Henge SH4500R4; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
HPQ Proliant U2+ AS/ES v2.6.9−22.0.2.EL AX150
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
110 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X QLogic QLA2340−E−SP12, 32 FC−AL, EMC Y16, 17
HPQ Proliant v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
DL360(G4)28; U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC2000,
NF420;
Lenovo SureServer: R630
6004, T630 6003
111 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X QLogic: QLA200−E−SP4, 20, 32, QLA210−E−SP4, FC−AL, EMC Y
RX300 S2, TX200 S2, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, 20, 32 FC−SW CLARiiON
TX300 S2 U2+ AS/ES v2.6.9−22.0.2.EL AX150
112 IBM xSeries: x3800/x260 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X23 Emulex: LP1050−E1, 4, 15, 31 , LP982−E1, 4, 15; FC−AL, EMC Y16, 17
(8865)24, 25, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
x3950/x3950E/x460 U2+ AS/ES v2.6.9−22.0.2.EL QLogic QLA2340−E−SP4, 12, 32 AX150
(8872, 8874)24, 25
113 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 15, QME24624, 32, 46 FC−AL, EMC Y16, 17
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, Express, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL PCI−X AX150
114 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, Emulex LP1050−E1, 4, 15, 59 ; FC−AL, EMC Y
RX800 S2 v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X QLogic: QLA2340−E−SP12, 32, QLA2340−E−SP4, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL 12, 32 AX150

11/02/2006 333 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
115 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, Emulex: LP101−E1, 4, 10, 15 , LP1050−E1, 15, 31, FC−AL, EMC Y16, 17
DL380(G4)28, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X LP982−E1, 15; FC−SW CLARiiON
DL580(G3)28, U2+ AS/ES v2.6.9−22.0.2.EL AX150
ML370(G4)28 QLogic: QLA200−E−SP4, 20, 32, QLA210−E−SP4,
20, 32, QLA2340−E−SP12, 32

116 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, Emulex: LP1050−E1, 4, 15, 31 , LP982−E1, 4, 15; FC−AL, EMC Y16, 17
1850, 2800, 2850; v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL QLogic QLA2340−E−SP4, 12, 32 AX150
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
117 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI, HPQ: AB429A/FC1143 (QLA2460)4, 32, 33, FC−AL, EMC Y16, 17
DL380(G4)28, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, PCI−X AE369A/FC1243 (QLA2462)4, 32, 33 FC−SW CLARiiON
ML370(G4)28 U2+ AS/ES v2.6.9−22.0.2.EL AX150
118 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP101−E1, 4, 59; FC−AL, EMC Y
RX300 S2, TX200 S2, v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP12 FC−SW CLARiiON
TX300 S2 U2+ AS/ES v2.6.9−22.0.2.EL, U3 AS/ES AX150
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL,
U3+ AS/ES v2.6.9−34.0.2.EL
119 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 15 ; FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, Express QLogic QLE2360−E−SP32, 40, 41 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
120 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LP101−E1, 10, 15, LP1050−E1, 15, 31, FC−AL, EMC Y16, 17
v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, Express LP982−E1, 15, LP982−E1, 4, 15; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
QLogic QLA2340−E−SP12, 32
121 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI Emulex: LPe111−E1, 4, 15, 37 , LPe1150−E1, 3, 4, 67; FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, Express FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL QLogic: QLE2360−E−SP4, 32, 40, 41 , AX150
LangChao: NC3000, QLE2460−E−SP4, 5, 32
NC3500, NF520;
Samsung ZSS230
122 LangChao: NC3000, Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP1050−E1, 4, 15, 31 ; FC−AL, EMC Y16, 17
NC3500, NF500, NF520; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, QLogic QLA2340−E−SP4, 12, 32 FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
Samsung ZSS230
123 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex LP982−E1, 4, 15 FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
124 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X Emulex: LP101−E1, 10, 15, LP1050−E1, 15, 31, FC−AL, EMC Y16, 17
HR−4850, HR−6850; v2.6.9−22.EL58, U2+ AS/ES v2.6.9−22.0.1.EL, LP982−E1, 15; FC−SW CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
LangChao: NC3000, QLogic QLA2340−E−SP12, 32
NC3500, NF500, NF520
125 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 4, 59 FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
126 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Fujitsu Siemens BX600−FC22Q4, 6, 12, 13 FC−AL, EMC Y
BX620 S3, BX630 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
(2−way), BX630 (4−way), U3+ AS/ES v2.6.9−34.0.2.EL AX150
BX630 (8−way)
127 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP101−E1, 2, 4, 10; FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL 20 AX150
Digital Henge Revo:
JS1400, JS2400
128 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 4, 31; FC−AL, EMC Y
2800, 2850 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express QLogic QLA2340−E−SP4, 6, 12 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
129 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 4, 10 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
130 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP982−E1, 2, 4 FC−AL, EMC Y
2800, 2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Samsung ZSS230

11/02/2006 334 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
131 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex: LP101−E1, 2, 10, LP1050−E1, 2, 31, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express LP982−E1, 2; FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
QLogic QLA2340−E−SP6, 12
132 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex: LPe111−E1, 2, 4, 37, LPe1150−E1, 2, 3, 4 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
133 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 2, 4, 14 FC−AL, EMC Y
DL360(G4)28, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
DL380(G4)28, U3+ AS/ES v2.6.9−34.0.2.EL AX150
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
134 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP4, 27, 29, 30 FC−AL, EMC Y
JS1400, JS2400 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
135 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP4, 29, 30 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
136 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLE2360−E−SP4, 6, 40, 41 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
137 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLE2360−E−SP6, 40, 41 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
138 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLE2460−E−SP4, 5, 6 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express FC−SW CLARiiON
6800, 6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
139 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP101−E1, 2, 4, 10; FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X 20 AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
HPQ Proliant
ML350(G4)28;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 335 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
140 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050−E1, 2, 4, 31 FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
141 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 4 FC−AL, EMC Y
RX220 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
142 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP1050Ex−E1, 2, 4, 10 FC−AL, EMC Y
2950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy:
RX600 S3, TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
143 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LP982−E1, 2, 4 FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
144 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LPe111−E1, 2, 4, 37; FC−AL, EMC Y
2950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, QLogic: QLE2360−E−SP4, 6, 40, 41 , FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X QLE2460−E−SP4, 5, 6 AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
145 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex LPe1150−E1, 2, 3, 4 FC−AL, EMC Y
2950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy:
RX220, RX600 S3, TX600
S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
146 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex: LP1050−E1, 2, 31, LP982−E1, 2; FC−AL, EMC Y
ML350(G4)28 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 33, 34, AX150
AE369A/FC1243 (QLA2462)4, 33, 35;
QLogic QLE220−E−SP4, 27, 29, 30
147 IBM xSeries: x3550 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI IBM: 24P0960 (QLA2340)4, 6, 12, 55 , 24P8053 FC−AL, EMC Y
(7978), x3650 (7979) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, (QLA2342)4, 6, 12, 39M5894 (QLA2460)4, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X 39M5895 (QLA2462)4; AX150
QLogic: QLA2460−E−SP4, 6, 64, QLE2360−E−SP4,
6, 65, QLE2460−E−SP4, 6, 64

148 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI NEC: N8190−120 (LP1050)11, 31, 60, 61 , FC−AL, EMC Y
120Li, 120Rg−1, 120Ri−2, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, N8190−127 (LPe1150)3, 11, 60, 61 FC−SW CLARiiON
140Hf, 140Re−4 U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
149 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP12 FC−AL, EMC Y
RX220, RX600 S3, TX600 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
S3 U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
150 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP4, 6, 12 FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Fujitsu Siemens Primergy:
RX220, RX600 S3, TX600
S3;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
151 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLA2340−E−SP6, 12 FC−AL, EMC Y
RX220, RX600 S3, TX600 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
S3; U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
HPQ Proliant
ML350(G4)28

11/02/2006 336 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
152 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI QLogic QLE220−E−SP4, 29, 30 FC−AL, EMC Y
1900, 2850, 2900, 2950, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
6800, 6850; U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
153 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI Emulex: LP101−E1, 2, 4, 10, LP1050−E1, 2, 31, FC−AL, EMC Y
JS1400, JS2400 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, LP982−E1, 2; FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X 22 AX150
QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6,
20, QLA2340−E−SP6, 12, QLE220−E−SP4, 27, 29,
30

154 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Dell: 2342M6, 12, LPe1105−M1, 2, 3, 4, QME24624, FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, 6, 46 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
155 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 2, 4, 10; FC−AL, EMC Y
1950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, QLogic QLA200−E−SP4, 6, 20 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
156 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP101−E1, 2, 10 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
LangChao: NC3000,
NC3500, NF500, NF520
157 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP1050−E1, 2, 4, 31; FC−AL, EMC Y
1950; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, QLogic QLA2340−E−SP4, 6, 12 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
158 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex LP982−E1, 2, 4 FC−AL, EMC Y
Digital Henge INNO: v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
HR−4850, HR−6850; U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26,
x3850/x366 (8863)24, 25;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
159 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X Emulex: LP1050−E1, 2, 31, LP982−E1, 2 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
HPQ Proliant
DL360(G4)28;
LangChao: NC3000,
NC3500, NF500, NF520
160 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y16, 17
(416653−B21), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, c−Class Bladesystem: (403621−B21)2, 69, 70, FC−SW CLARiiON
(416654−B21), U3+ AS/ES v2.6.9−34.0.2.EL (403621−B21)2, 69, 78 AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)

11/02/2006 337 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
161 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−AL, EMC N
(416653−B21), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, c−Class Bladesystem (403619−B21)35, 68 FC−SW CLARiiON
(416654−B21), U3+ AS/ES v2.6.9−34.0.2.EL AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
162 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 33, 34, FC−AL, EMC Y
DL360(G4)28 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, AE369A/FC1243 (QLA2462)4, 33, 35 FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
163 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X NEC N8190−120 (LP1050)1, 2, 10, 11 FC−AL, EMC Y
120Lh, 120Re−1, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
120Rf−1, 120Rg−2, U3+ AS/ES v2.6.9−34.0.2.EL AX150
120Rh−2, 140He,
140Rd−4
164 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 2, 11, 14 FC−AL, EMC Y
140He, 140Rd−4 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
165 Fujitsu Siemens Primergy: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X QLogic QLA200−E−SP4, 20 FC−AL, EMC Y
RX300 S2, TX200 S2, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
TX300 S2 U3+ AS/ES v2.6.9−34.0.2.EL AX150
166 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X QLogic QLA210−E−SP4, 6, 20 FC−AL, EMC Y
Digital Henge SH4500R4; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
Fujitsu Siemens Primergy: U3+ AS/ES v2.6.9−34.0.2.EL AX150
RX300 S2, TX200 S2,
TX300 S2;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
167 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X QLogic QLA2340−E−SP6, 12 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer: R630
6004, T630 6003
168 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X QLogic QLE220−E−SP4, 27, 29, 30 FC−AL, EMC Y
Fujitsu Siemens Primergy: v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, FC−SW CLARiiON
RX300 S2, TX200 S2, U3+ AS/ES v2.6.9−34.0.2.EL AX150
TX300 S2;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
169 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, PCI Dell: LPe1105−M1, 2, 3, 4, QME24624, 6, 46 FC−AL, EMC Y
v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
170 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, PCI Emulex: LP101−E1, 2, 4, 10, LP1050−E1, 2, 31, FC−AL, EMC Y
DL580(G3)28 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, LP982−E1, 2; FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6,
20, QLA2340−E−SP6, 12, QLE220−E−SP4, 27, 29,
30

171 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, PCI QLogic QLE220−E−SP4, 29, 30 FC−AL, EMC Y
2800 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, Express, FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL PCI−X AX150
172 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, Emulex LP1050−E1, 2, 4, 59 FC−AL, EMC Y
RX800 S2 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
173 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, Emulex: LP101−E1, 2, 4, 10, LP1050−E1, 2, 31, FC−AL, EMC Y
DL380(G4)28, v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X LP982−E1, 2; FC−SW CLARiiON
ML370(G4)28 U3+ AS/ES v2.6.9−34.0.2.EL AX150
HPQ: AB429A/FC1143 (QLA2460)4, 33, 34,
AE369A/FC1243 (QLA2462)4, 33, 35;
QLogic: QLA200−E−SP4, 6, 20, QLA210−E−SP4, 6,
20,
QLE220−E−SP4, 27, 29, 30
174 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, Emulex: LP1050−E1, 2, 4, 31, LP982−E1, 2, 4 FC−AL, EMC Y
1850, 2800, 2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
175 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP4, 6, 12 FC−AL, EMC Y
1850, 2800, 2850; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
Fujitsu Siemens Primergy
RX800 S2;
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140

11/02/2006 338 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
176 Fujitsu Siemens Primergy Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI, QLogic QLA2340−E−SP6, 12 FC−AL, EMC Y
RX800 S2; v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, PCI−X FC−SW CLARiiON
HPQ Proliant: U3+ AS/ES v2.6.9−34.0.2.EL AX150
DL380(G4)28,
ML370(G4)28
177 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP101−E1, 4, 10, 49 ; FC−AL, EMC Y
2800, 2850, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4, FC−SW CLARiiON
20, 48 AX150
Digital Henge Revo:
JS1400, JS2400
178 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP1050−E1, 4, 31, 49 ; FC−AL, EMC Y
2800, 2850 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express QLogic QLA2340−E−SP4, 12, 48 FC−SW CLARiiON
AX150
179 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP1050Ex−E1, 4, 10, 49 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
180 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP982−E1, 4, 49 FC−AL, EMC Y
2800, 2850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX150
Samsung ZSS230
181 Samsung ZSS230 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LP101−E1, 10, 49, LP1050−E1, 31, 49, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express LP982−E1, 49; FC−SW CLARiiON
AX150
QLogic QLA2340−E−SP12, 48
182 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LPe111−E1, 4, 37, 49 , LPe1150−E1, 3, 4, 49 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
HPQ Proliant:
DL360(G4)28,
DL380(G4)28,
DL580(G3)28,
ML350(G4)28,
ML370(G4)28;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
183 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI HPQ A8002A/FC2142SR (LPe1150)1, 4, 14, 49 FC−AL, EMC Y
DL360(G4)28, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
DL380(G4)28, AX150
DL580(G3)28,
ML350(G4)28,
ML370(G4)28
184 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP4, 27, 30, 38 FC−AL, EMC Y
JS1400, JS2400 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX150
185 Dell PowerEdge 1950 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP4, 30, 38 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX150
186 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP4, 40, 41, 48 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
IBM xSeries x336
(8837)26;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230

11/02/2006 339 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
187 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE2360−E−SP40, 41, 48 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
AX150
LangChao: NC3000,
NC3500, NF500, NF520;
Samsung ZSS230
188 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE2460−E−SP4, 5, 48 FC−AL, EMC Y
1850, 1950, 2800, 2850, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express FC−SW CLARiiON
6800, 6850; AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo:
JS1400, JS2400;
LangChao: NC3000,
NC3500, NF520;
Lenovo SureServer:
R650, T650;
Samsung: ZSS150,
ZSS230
189 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP101−E1, 4, 10, 49 ; FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4, FC−SW CLARiiON
PCI−X 20, 48 AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
HPQ Proliant
ML350(G4)28;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
190 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP1050−E1, 4, 31, 49 ; FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, QLogic QLA2340−E−SP4, 12, 48 FC−SW CLARiiON
PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
IBM xSeries: x3550
(7978), x3650 (7979);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
191 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex LP982−E1, 4, 49 FC−AL, EMC Y
2950, 6800, 6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
192 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LP1050−E1, 31, 49, LP982−E1, 49; FC−AL, EMC Y
ML350(G4)28 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 33, 48, AX150
AE369A/FC1243 (QLA2462)4, 33, 48;
QLogic: QLA2340−E−SP12, 48, QLE220−E−SP4,
27, 30, 38

193 Dell PowerEdge: 2900, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LP1050Ex−E1, 4, 10, 49 , LPe111−E1, 4, 37, FC−AL, EMC Y
2950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, 49, LPe1150−E1, 3, 4, 49; FC−SW CLARiiON
PCI−X AX150
Digital Henge Revo: QLogic: QLE2360−E−SP4, 40, 41, 48 ,
AS1500, AS1550, QLE2460−E−SP4, 5, 48
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
194 IBM xSeries: x3550 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI IBM: 24P0960 (QLA2340)4, 12, 48, 55 , 24P8053 FC−AL, EMC Y
(7978), x3650 (7979) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, (QLA2342)4, 12, 48; FC−SW CLARiiON
PCI−X AX150
QLogic: QLA2460−E−SP4, 48, 64,
QLE2360−E−SP4, 48, 65, QLE2460−E−SP4, 48, 64
195 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI NEC: N8190−120 (LP1050)11, 31, 49, 61 , FC−AL, EMC Y
120Li, 120Rg−1, 120Ri−2, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, N8190−127 (LPe1150)3, 11, 49, 61 FC−SW CLARiiON
140Hf, 140Re−4 PCI−X AX150
196 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI QLogic QLE220−E−SP4, 30, 38 FC−AL, EMC Y
1900, 2850, 2900, 2950, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
6800, 6850; PCI−X AX150
Digital Henge Revo:
AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
197 Digital Henge Revo: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI Emulex: LP101−E1, 4, 10, 49 , LP1050−E1, 31, 49, FC−AL, EMC Y
JS1400, JS2400 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E1, 49; FC−SW CLARiiON
PCI−X 22 AX150
QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4,
20, 48, QLA2340−E−SP12, 48, QLE220−E−SP4, 27,
30, 38

11/02/2006 340 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
198 Dell PowerEdge 1855 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X Dell: 2342M12, 48, LPe1105−M1, 3, 4, 49, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL QME24624, 46, 48 FC−SW CLARiiON
AX150
199 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X Emulex LP101−E1, 4, 10, 49 ; FC−AL, EMC Y
1950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL QLogic QLA200−E−SP4, 20, 48 FC−SW CLARiiON
AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
200 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X Emulex LP101−E1, 10, 49 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX150
LangChao: NC3000,
NC3500, NF500, NF520
201 Dell PowerEdge: 1850, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X Emulex LP1050−E1, 4, 31, 49 ; FC−AL, EMC Y
1950; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL QLogic QLA2340−E−SP4, 12, 48 FC−SW CLARiiON
AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
202 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X Emulex LP982−E1, 4, 49 FC−AL, EMC Y
Digital Henge INNO: v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
HR−4850, HR−6850; AX150
Digital Henge SH4500R4;
IBM xSeries: x255, x336
(8837)26, x346 (8840)26;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer:
R650, T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150,
ZSS230
203 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X Emulex: LP1050−E1, 31, 49, LP982−E1, 49 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX150
HPQ Proliant
DL360(G4)28;
LangChao: NC3000,
NC3500, NF500, NF520
204 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y16, 17
(416653−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL c−Class Bladesystem (403621−B21)49, 69, 77 FC−SW CLARiiON
(416654−B21), AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
205 HPQ Proliant BL460c: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP FC−AL, EMC N
(416653−B21), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL c−Class Bladesystem (403619−B21)48, 68 FC−SW CLARiiON
(416654−B21), AX150
(416655−B21),
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21),
(416669−B21)
206 HPQ Proliant Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X HPQ: AB429A/FC1143 (QLA2460)4, 33, 48, FC−AL, EMC Y
DL360(G4)28 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL AE369A/FC1243 (QLA2462)4, 33, 48 FC−SW CLARiiON
AX150
207 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X NEC N8190−120 (LP1050)1, 10, 11, 49 FC−AL, EMC Y
120Lh, 120Re−1, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
120Rf−1, 120Rg−2, AX150
120Rh−2, 140He,
140Rd−4

11/02/2006 341 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
208 NEC Express 5800: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X NEC N8190−127 (LPe1150)1, 11, 14, 49 FC−AL, EMC Y
140He, 140Rd−4 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX150
209 Dell PowerEdge 1850; Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X QLogic QLA210−E−SP4, 20, 48 FC−AL, EMC Y
Digital Henge SH4500R4; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
HPQ Proliant AX150
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
210 Digital Henge INNO: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X QLogic QLA2340−E−SP12, 48 FC−AL, EMC Y
HR−4850, HR−6850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
AX150
Digital Henge SH4500R4;
HPQ Proliant
DL360(G4)28;
LangChao: NC2000,
NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer: R630
6004, T630 6003
211 Digital Henge SH4500R4; Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X QLogic QLE220−E−SP4, 27, 30, 38 FC−AL, EMC Y
Fujitsu Siemens Primergy: v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL FC−SW CLARiiON
RX300 S2, TX200 S2, AX150
TX300 S2;
HPQ Proliant
DL360(G4)28;
LangChao NF420;
Lenovo SureServer: R630
6004, T630 6003
212 Dell PowerEdge 1955 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI Dell: LPe1105−M1, 3, 4, 49, QME24624, 46, 48 FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX150
213 HPQ Proliant DL380(G5) Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI Emulex: LP101−E1, 4, 10, 49 , LP1050−E1, 31, 49, FC−AL, EMC Y
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, LP982−E1, 49; FC−SW CLARiiON
PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)4, 33, 48,
AE369A/FC1243 (QLA2462)4, 33, 48;
QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4,
20, 48, QLA2340−E−SP12, 48

214 HPQ Proliant: DL380(G5), Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI Emulex: LPe111−E1, 4, 37, 49 , LPe1150−E1, 3, 4, 49; FC−AL, EMC Y
DL580(G4) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X HPQ: A8002A/FC2142SR (LPe1150)1, 4, 14, 49 , AX150
AE311A/FC1142SR (QLE2460)4, 5, 48,
AE312A/FC1242SR (QLE2462)4, 5, 48;
QLogic: QLE2460−E−SP4, 5, 48, QLE2462−E−SP4,
5, 48

215 HPQ Proliant: DL380(G5), Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP4, 27, 30, 38 FC−AL, EMC Y
DL580(G3)28, DL580(G4) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX150
216 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, PCI QLogic QLE220−E−SP4, 30, 38 FC−AL, EMC Y
2800 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL Express, FC−SW CLARiiON
PCI−X AX150
217 HPQ Proliant: Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, Emulex: LP101−E1, 4, 10, 49 , LP1050−E1, 31, 49, FC−AL, EMC Y
DL380(G4)28, v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X LP982−E1, 49; FC−SW CLARiiON
ML370(G4)28 AX150
HPQ: AB429A/FC1143 (QLA2460)4, 33, 48,
AE369A/FC1243 (QLA2462)4, 33, 48;
QLogic: QLA200−E−SP4, 20, 48, QLA210−E−SP4,
20, 48,
QLA2340−E−SP12, 48, QLE220−E−SP4, 27,
30, 38

218 Dell PowerEdge: 1800, Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI, Emulex: LP1050−E1, 4, 31, 49 , LP982−E1, 4, 49; FC−AL, EMC Y
1850, 2800, 2850; v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP4, 12, 48 AX150
IBM xSeries: x365, x440,
x445 (8870);
Samsung: ES470, ES570,
SS140
219 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843) v2.4.21−40.EL18, 19 (39Y9186)4, 39, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 21, HS20 FC Exp Card AX150
(26K4841)4, 12, 21
220 IBM BladeCenter HS21 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y52
(Model 8853)51 v2.4.21−40.EL18, 19 (39Y9186)4, 39, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 9, 21, HS20 FC Exp Card AX150
(13N2203)4, 12, 21, HS20 FC Exp Card
(48P7061)4, 12, 21
221 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U7 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 4, 39, 50 , FC−SW EMC Y
(Model: 8832−N1X), v2.4.21−40.EL18, 19 HS20 4GB Standard FC Exp Card (26R0884)4, 7, CLARiiON
8843) 21, HS20 FC Exp Card (13N2203)4, 12, 21, HS20 AX150
FC Exp Card (48P7061)4, 12, 21
222 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843) v2.4.21−47.EL18, 19 (39Y9186)4, 36, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 56, HS20 FC Exp Card AX150
(26K4841)4, 12, 56
223 IBM BladeCenter HS21 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y52
(Model 8853)51 v2.4.21−47.EL18, 19 (39Y9186)4, 36, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
Card (26R0890)4, 8, 9, 56, HS20 FC Exp Card AX150
(13N2203)4, 12, 56, HS20 FC Exp Card
(48P7061)4, 12, 56

11/02/2006 342 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
224 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0 U8 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 4, 36, 50 , FC−SW EMC Y
(Model: 8832−N1X), v2.4.21−47.EL18, 19 HS20 4GB Standard FC Exp Card (26R0884)4, 7, CLARiiON
8843) 56, HS20 FC Exp Card (13N2203)4, 12, 56, HS20 AX150
FC Exp Card (48P7061)4, 12, 56
225 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)4, 12, 75, 79 FC−SW EMC Y17, 45
(Model 8843) v2.4.21−32.EL18, 73, U5+ AS/ES CLARiiON
v2.4.21−32.0.1.EL18, 73 AX150
226 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U5 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)4, 12, 75, 79 , FC−SW EMC Y17, 45
(Model: 8832−N1X), v2.4.21−32.EL18, 73, U5+ AS/ES (48P7061)4, 12, 75, 79 CLARiiON
8843) v2.4.21−32.0.1.EL18, 73 AX150
227 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X IBM HS20 4GB SFF FC Exp Card (26R0890)4, 8, FC−SW EMC N17, 45
(Model 8843) v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL 21 CLARiiON
AX150
228 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X IBM HS20 4GB Standard FC Exp Card FC−SW EMC N17, 45
(Model: 8832−N1X), v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL (26R0884)4, 7, 21 CLARiiON
8843) AX150
229 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)4, 12, 21 FC−SW EMC Y17, 45
(Model 8843) v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL CLARiiON
AX150
230 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 3.0: U6 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 4, 47, 50 , FC−SW EMC Y17, 45
(Model: 8832−N1X), v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL HS20 FC Exp Card (13N2203)4, 12, 21, HS20 FC CLARiiON
8843) Exp Card (48P7061)4, 12, 21 AX150
231 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X IBM HS20: 4GB SFF FC Exp Card (26R0890)4, 8, FC−SW EMC Y16, 17
(Model 8843) v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, 9, 66, FC Exp Card (26K4841)4, 12, 32 CLARiiON
U2+ AS/ES v2.6.9−22.0.2.EL AX150
232 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U2 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 4, 15, 50 , FC−SW EMC Y16, 17
(Model: 8832−N1X), v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, HS20 4GB Standard FC Exp Card (26R0884)4, 7, CLARiiON
8843) U2+ AS/ES v2.6.9−22.0.2.EL 32, HS20 FC Exp Card (13N2203)4, 12, 32, HS20 AX150
FC Exp Card (48P7061)4, 12, 32
233 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)4, 6, 12 FC−SW EMC Y
(Model 8843) v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, CLARiiON
U3+ AS/ES v2.6.9−34.0.2.EL AX150
234 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)4, 6, 12, FC−SW EMC Y
(Model: 8832−N1X), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, (48P7061)4, 6, 12 CLARiiON
8843); U3+ AS/ES v2.6.9−34.0.2.EL AX150
IBM BladeCenter HS21
(Model 8853)51
235 IBM BladeCenter: HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843), HS21 v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, (39Y9186)2, 4, 53, 54 , HS20 4GB SFF FC Exp Card CLARiiON
(Model 8853)51 U3+ AS/ES v2.6.9−34.0.2.EL (26R0890)4, 6, 8, 9 AX150
236 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U3 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 2, 4, 50, FC−SW EMC Y
(Model: 8832−N1X), v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, HS20 4GB Standard FC Exp Card (26R0884)4, 6, 7 CLARiiON
8843) U3+ AS/ES v2.6.9−34.0.2.EL AX150
237 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card (26K4841)4, 12, 48 FC−SW EMC Y
(Model 8843) v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL CLARiiON
AX150
238 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X IBM HS20 FC Exp Card: (13N2203)4, 12, 48, FC−SW EMC Y
(Model: 8832−N1X), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (48P7061)4, 12, 48 CLARiiON
8843); AX150
IBM BladeCenter HS21
(Model 8853)51
239 IBM BladeCenter: HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843), HS21 v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL (39Y9186)4, 49, 53, 54 , HS20 4GB SFF FC Exp CLARiiON
(Model 8853)51 Card (26R0890)4, 8, 9, 48 AX150
240 IBM BladeCenter HS20 Red Hat RHEL [EM64T] 4.0: U4 AS/ES PCI−X IBM: Emulex LP1005DC FC Exp Card1, 4, 49, 50 , FC−SW EMC Y
(Model: 8832−N1X), v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL HS20 4GB Standard FC Exp Card (26R0884)4, 7, CLARiiON
8843) 48 AX150
1. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
2. Driver Version 8.0.16.18 Driver is integrated into the kernel.
3. Firmware Version 2.50a6
4. SNIA HBA API Supported.
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 8.01.02−d4 Driver is integrated into the kernel.
7. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.12
9. Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
12. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
14. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
15. Driver Version 8.0.16.17 Driver is integrated into the kernel.
16. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
17. VxVM is not supported on servers booting from the array.
18. Red Hat does not currently support reiserfs on RHEL 3.0. As a result, EMC supports only the ext2 and ext3 filesystems on RHEL 3.0. If there is a customer requirement for a different
filesystem, please submit an RPQ.
19. The LVM included as part of this update is supported and can be used in conjunction with PowerPath emcpower pseudo device file names as well as native sd device file names.
20. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Driver Version 7.07.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. PCI−X slots in this server only support low−profile hbas with low−profile brackets. Please ensure your HBA vendor has included the proper bracket to fit this server.
23. Accepts PCI−X 1.0 and 2.0 HBAs.
24. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
25. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
26. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
27. Driver/BIOS are available at http://www.qlogic.com
28. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
29. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
30. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
31. Firmware Version 1.91a5
32. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

11/02/2006 343 CLARiiON AX150


CLARiiON AX150

34. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
35. Driver Version 8.01.02−d4 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. Driver Version 7.3.6 Driver is integrated into the kernel.
37. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
38. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
39. Driver Version 7.3.3 Driver is integrated into the kernel.
40. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
41. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
42. Driver Version 7.07.05 Driver/BIOS are available at http://www.qlogic.com
43. Driver Version 8.00.03b−1 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
44. For Emulex attach, a LUN within the range of 000 −007 must exist in order for the FC driver to scan all devices.
For QLogic attach, LUN 000 must exist in order for the FC driver to scan all devices.
45. Booting from the SAN with PowerPath is not supported.
46. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
47. Driver Version 7.3.2 Driver is integrated into the kernel.
48. Driver Version 8.01.04−d7 Driver is integrated into the kernel.
49. Driver Version 8.0.16.27 Driver is integrated into the kernel.
50. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
51. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
52. PowerPath is not supported.
53. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
54. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
55. This HBA is equivalent to the QLogic QLA2340.
56. Driver Version 7.07.04−b6 Driver is integrated into the kernel.
57. Driver Version 7.07.00
58. dual core machine not support
59. Firmware Version 1.91a1
60. Driver Version 8.0.16.18
61. BIOS 1.70a3
62. Driver Version 7.07.05
63. BIOS 1.02
64. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
65. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Available in the EMC−approved section of the Emulex website. http://www.emulex.com
66. Driver Version 8.01.00
67. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
68. BIOS 1.16
69. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
70. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
71. Driver Version 7.3.2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
72. Driver Version 8.0.16.6_x2 Driver is integrated into the kernel.
73. The LVM integrated into the kernel is supported. Please note, however, that the LVM will not recognize PowerPath emcpower pseudo device file names. The native sd device file names
must be used.
74. Driver Version 7.01.01 Driver is integrated into the kernel.
75. Driver Version 7.03.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
76. Driver Version 7.1.14 Driver is integrated into the kernel.
77. Firmware Version 2.50a8
78. Firmware Version 2.50a8 Driver is integrated into the kernel.
79. Driver Version 7.01.01−RH1 Driver is integrated into the kernel.
80. Driver Version 7.04.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
81. Driver Version 7.1.14 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
82. Driver Version 7.1.14 Driver/Firmware available at http://www.emulex.com
83. Driver Version 2.02e Driver/Firmware available at http://www.emulex.com

SuSE SLES [32−Bit]

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Primergy: BX620 S3, BX630 SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI Emulex LP1050−E2, 19, 45, 46 FC−AL, EMC Y
(2−way), BX630 (4−way) FC−SW CLARiiON
AX150
2 HPQ Proliant BL465c: (403433−B21), SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y21, 22,
(403434−B21), (407234−B21), (407235−B21) Express HBA for HP c−Class Bladesystem FC−SW CLARiiON Y57
(403621−B21)54, 55, 56 AX150
3 HPQ Proliant BL465c: (403433−B21), SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI HPQ QLogic QMH2462 4Gb FC HBA FC−AL, EMC N
(403434−B21), (407234−B21), (407235−B21) Express for HP c−Class Bladesystem FC−SW CLARiiON
(403619−B21)15, 51 AX150
4 HPQ Proliant BL465c: (403433−B21), SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(403434−B21), (407234−B21), (407235−B21) Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
(403621−B21)54, 55, 56, QLogic AX150
QMH2462 4Gb FC HBA for HP c−Class
Bladesystem (403619−B21)15, 51
5 Dell PowerEdge 1950 SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI QLogic QLE220−E−SP2, 13, 14 FC−AL, EMC Y
Express FC−SW CLARiiON
AX150
6 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI QLogic QLE220−E−SP2, 13, 14 FC−AL, EMC Y
6800, 6850, 6950; Express, FC−SW CLARiiON
PCI−X AX150
Digital Henge Revo: AS1500, AS1550, AS2500;
Intel: SR1500/S5000PAL, SR2500/S5000PAL
7 Dell PowerEdge: 1800, 2800 SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI, PCI QLogic QLE220−E−SP2, 13, 14 FC−AL, EMC Y
Express, FC−SW CLARiiON
PCI−X AX150
8 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LP101−E2, 19, 25, 36 ; FC−AL, EMC Y21, 22
255052, 4300, 4350, 4400, 6100, 6300, 6350, 6400, v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP2, 32, 50, FC−SW CLARiiON
6450, 8450; QLA210−E−SP2, 32, 50, AX150
QLA2340−E−SP3, 32
HPQ Proliant: DL32048, DL360(G2)48, DL36048,
DL380(G2)48, DL380(G3)48, DL38048, DL580(G2)48,
DL58048, ML350(G2)48, ML350(G3)48, ML35048,
ML370(G2)48, ML37048, ML530(G2)48,
ML530(G3)48, ML53048, ML57048, ML75048

11/02/2006 344 CLARiiON AX150


CLARiiON AX150

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
9 Fujitsu Siemens Primergy BX630: (2−way), (4−way) SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LP1050−E2, 19, 31, 45 ; FC−AL, EMC Y
v2.6.5−7.201, v2.6.5−7.202.7 Fujitsu Siemens BX600−FC22Q2, 3, 27, FC−SW CLARiiON
28 AX150
10 Dell PowerEdge: 1550, 2300, 2400, 2450, 2500, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050−E2, 19, 20, 25 , FC−AL, EMC Y21, 22
255052, 4300, 4350, 4400, 6100, 6300, 6350, 6400, v2.6.5−7.201, v2.6.5−7.202.7 LP982−E2, 19, 25; FC−SW CLARiiON
6450, 8450 AX150
QLogic QLA2340−E−SP2, 3, 32
11 HPQ Proliant: DL32048, DL360(G2)48, DL36048, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050−E19, 20, 25, FC−AL, EMC Y21, 22
DL58048, ML350(G2)48, ML350(G3)48, ML35048, v2.6.5−7.201, v2.6.5−7.202.7 LP982−E19, 25 FC−SW CLARiiON
ML370(G2)48, ML37048, ML530(G2)48, AX150
ML530(G3)48, ML53048, ML57048, ML75048
12 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LP1050Ex−E2, 19, 24, 36 ; FC−AL, EMC Y21, 22
6800, 6850; v2.6.5−7.201, v2.6.5−7.202.7 Express QLogic QLE2360−E−SP2, 32, 34, 35 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
IBM xSeries x336 (8837)44;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
13 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LPe111−E2, 19, 29, 31 FC−AL, EMC Y21, 22
6800, 6850; v2.6.5−7.201, v2.6.5−7.202.7 Express FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
HPQ Proliant: DL360(G4)48, DL380(G4)48,
ML350(G4)48, ML370(G4)48;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
14 HPQ Proliant: DL360(G4)48, DL380(G4)48, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LPe1150−E2, 19, 23, 25 ; FC−AL, EMC Y21, 22
ML350(G4)48, ML370(G4)48 v2.6.5−7.201, v2.6.5−7.202.7 Express HPQ A8002A/FC2142SR (LPe1150)2, FC−SW CLARiiON
19, 24, 49 AX150
15 Dell PowerEdge: 1800, 1850, 1950, 2800, 2850, SuSE SLES [32−Bit] 9 SP2+: PCI Emulex LPe1150−E2, 19, 23, 33 ; FC−AL, EMC Y21, 22
6800, 6850; v2.6.5−7.201, v2.6.5−7.202.7 Express QLogic QLE2460−E−SP2, 26, 32 FC−SW CLARiiON
AX150
Digital Henge INNO: HR−4850, HR−6850;
Digital Henge Revo: JS1400, JS2400;
LangChao: NC3000, NC3500, NF520;
Lenovo SureServer: R650, T650;
Samsung: ZSS150, ZSS230
16 Dell PowerEdge: 2900, 2950, 6950 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP101−E2, 19, 24, 36 , FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050−E2, 19, 20, 24 , LP982−E2, 19, 24; FC−SW CLARiiON
PCI−X AX150
QLogic QLA2340−E−SP2, 3, 32
17 HPQ Proliant ML350(G4)48 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP101−E2, 19, 25, 36 , FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 Express, LP1050−E19, 20, 25, LP982−E19, 25; FC−SW CLARiiON
PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)2, 32,
62, AE369A/FC1243 (QLA2462)2, 32, 62;

QLogic: QLA200−E−SP2, 32, 50,


QLA210−E−SP2, 32, 50,
QLA2340−E−SP3, 32
18 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E2, 19, 24, 36 , FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe111−E2, 19, 29, 31 , LPe1150−E2, 19, FC−SW CLARiiON
IBM eServer 326m (Model 7969) PCI−X 23, 33; AX150
QLogic: QLE2360−E−SP2, 32, 34, 35 ,
QLE2460−E−SP2, 26, 32
19 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LP1050Ex−E2, 19, 24, FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 Express, LPe1150−E2, 19, 23, LPe1150−E2, 19, 23, FC−SW CLARiiON
PCI−X 25 AX150
20 Dell PowerEdge 1855; SuSE SLES [32−Bit] 9 SP2+: PCI−X Dell 2342M3, 32 FC−AL, EMC Y21, 22
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX150
21 Dell PowerEdge 1855 SuSE SLES [32−Bit] 9 SP2+: PCI−X Dell: LPe1105−M2, 19, 23, 24 , FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 QME24622, 32, 53 FC−SW CLARiiON
AX150
22 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP101−E2, 19, 25, 36 ; FC−AL, EMC Y21, 22
6650; v2.6.5−7.201, v2.6.5−7.202.7 QLogic: QLA200−E−SP2, 32, 50, FC−SW CLARiiON
QLA210−E−SP2, 32, 50, AX150
HPQ Proliant: BL40p, DL360(G3)48, DL360(G4)48, QLA2340−E−SP3, 32
DL56048, DL74048, DL760 (G2)48, DL76048,
ML570(G2)48
23 HPQ Proliant: BL40p, DL360(G3)48, DL360(G4)48, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP1050−E19, 20, 25 FC−AL, EMC Y21, 22
DL56048, DL760 (G2)48, DL76048, ML570(G2)48 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX150
24 HPQ Proliant DL760 (G2)48 SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP982−E19 FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX150

11/02/2006 345 CLARiiON AX150


CLARiiON AX150

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
25 HPQ Proliant: BL40p, DL360(G3)48, DL360(G4)48, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex LP982−E19, 25 FC−AL, EMC Y21, 22
DL56048, DL76048, ML570(G2)48 v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
AX150
26 Dell PowerEdge: 6800, 6850; SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex: LP101−E2, 19, 24, 36 , FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 LP1050−E2, 19, 20, 24 , LP982−E2, 19, 24 FC−SW CLARiiON
Digital Henge SH4500R4; AX150
IBM xSeries: x336 (8837)44, x346 (8840)44,
x3850/x366 (8863)41, 42;
LangChao: NC2000, NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230
27 Dell PowerEdge: 1600SC, 1650, 1750, 4600, 6600, SuSE SLES [32−Bit] 9 SP2+: PCI−X Emulex: LP1050−E2, 19, 20, 25 , FC−AL, EMC Y21, 22
6650 v2.6.5−7.201, v2.6.5−7.202.7 LP982−E2, 19, 25 FC−SW CLARiiON
AX150
28 HPQ Proliant DL360(G4)48 SuSE SLES [32−Bit] 9 SP2+: PCI−X HPQ: AB429A/FC1143 (QLA2460)2, 32, FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 62, AE369A/FC1243 (QLA2462)2, 32, 62 FC−SW CLARiiON
AX150
29 Dell PowerEdge: 1600SC, 1650, 1750, 6800, 6850; SuSE SLES [32−Bit] 9 SP2+: PCI−X QLogic QLA2340−E−SP2, 3, 32 FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 FC−SW CLARiiON
Digital Henge SH4500R4; AX150
IBM xSeries: x336 (8837)44, x346 (8840)44,
x3850/x366 (8863)41, 42;
LangChao: NC2000, NC3000, NC3500, NF420,
NF500, NF520;
Lenovo SureServer R630: 6003, 6004;
Lenovo SureServer: R650, T630 6003, T650;
Samsung: SS210, SS370, SS3840, ZSS150,
ZSS230
30 IBM xSeries: x3800/x260 (8865)41, 42, SuSE SLES [32−Bit] 9 SP2+: PCI−X43 Emulex: LP101−E2, 19, 24, 36 , FC−AL, EMC Y21, 22
x3950/x3950E/x460 (8872, 8874)41, 42 v2.6.5−7.201, v2.6.5−7.202.7 LP1050−E2, 19, 20, 24 , LP982−E2, 19, 24; FC−SW CLARiiON
AX150
QLogic QLA2340−E−SP2, 3, 32
31 Dell PowerEdge 1955 SuSE SLES [32−Bit] 9 SP2+: PCI, PCI Dell: LPe1105−M2, 19, 23, 24 , FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 Express, QME24622, 32, 53 FC−SW CLARiiON
PCI−X AX150
32 HPQ Proliant DL38048 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex LP982−E19 FC−AL, EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
AX150
33 HPQ Proliant: DL14548, DL380(G2)48, DL380(G3)48, SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex LP982−E19, 25 FC−AL, EMC Y21, 22
DL380(G4)48, DL38548, DL580(G2)48, DL58548, v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
ML370(G3)48, ML370(G4)48 AX150
34 Dell PowerEdge: 1800, 1850, 2600, 2650, 2800, SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E2, 19, 24, 36 , FC−AL, EMC Y21, 22
2850; v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP1050−E2, 19, 20, 24 , LP982−E2, 19, 24; FC−SW CLARiiON
AX150
Samsung: ES470, ES570, SS140 QLogic QLA2340−E−SP2, 3, 32
35 HPQ Proliant: DL14548, DL380(G2)48, DL380(G3)48, SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E2, 19, 25, 36 , FC−AL, EMC Y21, 22
DL380(G4)48, DL38048, DL38548, DL580(G2)48, v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP1050−E19, 20, 25; FC−SW CLARiiON
DL58548, ML370(G3)48, ML370(G4)48 AX150
QLogic: QLA200−E−SP2, 32, 50,
QLA210−E−SP2, 32, 50
36 HPQ Proliant: DL380(G4)48, DL38548, DL58548, SuSE SLES [32−Bit] 9 SP2+: PCI, HPQ: AB429A/FC1143 (QLA2460)2, 32, FC−AL, EMC Y21, 22
ML370(G4)48 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X 62, AE369A/FC1243 (QLA2462)2, 32, 62 FC−SW CLARiiON
AX150
37 HPQ Proliant: DL14548, DL380(G4)48, DL38548, SuSE SLES [32−Bit] 9 SP2+: PCI, QLogic QLA2340−E−SP3, 32 FC−AL, EMC Y21, 22
DL580(G2)48, DL58548, ML370(G3)48, ML370(G4)48 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X FC−SW CLARiiON
AX150
38 HPQ Proliant DL580(G3)48 SuSE SLES [32−Bit] 9 SP2+: PCI Emulex: LPe111−E2, 19, 29, 31 , FC−AL, EMC Y21, 22
v2.6.5−7.2015, 6, 9, Express LPe1150−E2, 19, 23, 25 ; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
HPQ A8002A/FC2142SR (LPe1150)2,
19, 24, 49

39 HPQ Proliant DL580(G3)48 SuSE SLES [32−Bit] 9 SP2+: PCI, Emulex: LP101−E2, 19, 25, 36 , FC−AL, EMC Y21, 22
v2.6.5−7.2015, 6, 9, PCI−X LP1050−E19, 20, 25, LP982−E19, 25; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
QLogic: QLA200−E−SP2, 32, 50,
QLA210−E−SP2, 32, 50,
QLA2340−E−SP3, 32
40 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9 SP3: PCI Unisys: FCH732213−P64 FC−AL, EMC Y
ES7000/540 v2.6.5−7.244, v2.6.5−7.2445, 6, 9; (LP9002L−F2)18, 19, 40, FC−SW CLARiiON
FCH742313−P64 (LP9802)18, 19, 36, AX150
SuSE SLES [32−Bit] 9 SP3+: FCH752313−PCX (LP1050)18, 19, 36
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282
41 Unisys ES7000/460 [32−Bit] SuSE SLES [32−Bit] 9 SP3: PCI, Unisys: FCH732213−P64 FC−AL, EMC Y
v2.6.5−7.244, v2.6.5−7.2445, 6, 9; PCI−X (LP9002L−F2)18, 19, 40, FC−SW CLARiiON
FCH742313−P64 (LP9802)18, 19, 36, AX150
SuSE SLES [32−Bit] 9 SP3+: FCH752313−PCX (LP1050)18, 19, 36
v2.6.5−7.252, v2.6.5−7.257,
v2.6.5−7.267, v2.6.5−7.276,
v2.6.5−7.282

11/02/2006 346 CLARiiON AX150


CLARiiON AX150

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
42 Unisys: ES7000/510, ES7000/520, ES7000/530, SuSE SLES [32−Bit] 9: SP3 PCI Unisys: FCH732213−P64 FC−AL, EMC Y4
ES7000/540 v2.6.5−7.244, SP3+ (LP9002L−F2)18, 19, 40, FC−SW CLARiiON
v2.6.5−7.252, SP3+ FCH742313−P64 (LP9802)18, 19, 36, AX150
v2.6.5−7.257, SP3+ FCH752313−PCX (LP1050)18, 19, 36
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
43 IBM xSeries x3455 (7984) SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E2, 18, 19, 36 ; FC−AL, EMC Y, Y4
v2.6.5−7.244, SP3+ Express IBM: 42C2069 (LPe11000)2, 18, 19, 49 , FC−SW CLARiiON
v2.6.5−7.252, SP3+ 42C2071 (LPe11002)2, 18, 19, 49 ; AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+ QLogic: QLE2360−E−SP1, 2, 35,
v2.6.5−7.276, SP3+ QLE2460−E−SP1, 2, 26
v2.6.5−7.282
44 HPQ Proliant BL465c: (403433−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y21, 22,
(403434−B21), (407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express HBA for HP c−Class Bladesystem FC−SW CLARiiON Y57
v2.6.5−7.252, SP3+ (403621−B21)18, 55, 56 AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
45 HPQ Proliant BL465c: (403433−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ QLogic QMH2462 4Gb FC HBA FC−AL, EMC N
(403434−B21), (407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express for HP c−Class Bladesystem FC−SW CLARiiON
v2.6.5−7.252, SP3+ (403619−B21)1, 15 AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
46 HPQ Proliant BL465c: (403433−B21), SuSE SLES [32−Bit] 9: SP3 PCI HPQ: Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y
(403434−B21), (407234−B21), (407235−B21) v2.6.5−7.244, SP3+ Express HBA for HP c−Class Bladesystem FC−SW CLARiiON
v2.6.5−7.252, SP3+ (403621−B21)18, 55, 56, QLogic AX150
v2.6.5−7.257, SP3+ QMH2462 4Gb FC HBA for HP c−Class
v2.6.5−7.267, SP3+ Bladesystem (403619−B21)1, 15
v2.6.5−7.276, SP3+
v2.6.5−7.282
47 Dell PowerEdge 1950 SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLE220−E−SP2, 14, 17 FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
48 Fujitsu Siemens Primergy RX300 S3 SuSE SLES [32−Bit] 9: SP3 PCI QLogic: QLA2340−E−SP1, 2, 3, FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express QLA2340−E−SP1, 3, QLA2340−E−SP2, FC−SW CLARiiON
v2.6.5−7.252, SP3+ 3, QLA2340−E−SP3 AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
49 Fujitsu Siemens Primergy RX220 SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E2, 18, 19 FC−AL, EMC Y, Y4
v2.6.5−7.244, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
50 IBM xSeries: x3550 (7978), x3650 (7979), x3755 SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050Ex−E2, 18, 19, 36 ; FC−AL, EMC Y
(8877) v2.6.5−7.244, SP3+ Express, IBM: 24P0960 (QLA2340)2, 3, 16, 59 , FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 24P8053 (QLA2342)2, 3, 16, 39M5894 AX150
v2.6.5−7.257, SP3+ (QLA2460)1, 2, 26, 39M5895
v2.6.5−7.267, SP3+ (QLA2462)1, 2, 26;
v2.6.5−7.276, SP3+
v2.6.5−7.282 QLogic: QLA2460−E−SP1, 2, 26,
QLE2360−E−SP1, 2, 35,
QLE2460−E−SP1, 2, 26
51 Fujitsu Siemens Primergy RX220; SuSE SLES [32−Bit] 9: SP3 PCI Emulex LPe1150−E2, 18, 19, 23 ; FC−AL, EMC Y4
IBM xSeries: x3550 (7978), x3650 (7979), x3755 v2.6.5−7.244, SP3+ Express, QLogic QLA2340−E−SP1, 2, 3 FC−SW CLARiiON
(8877) v2.6.5−7.252, SP3+ PCI−X AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
52 IBM xSeries: x3550 (7978), x3650 (7979), x3755 SuSE SLES [32−Bit] 9: SP3 PCI Emulex: LP1050−E2, 18, 19, 20 , FC−AL, EMC Y4
(8877) v2.6.5−7.244, SP3+ Express, LP1050Ex−E2, 18, 19, 36 , LP1150−E2, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 18, 19, 60 , LP982−E2, 18, 19, LPe111−E2, AX150
v2.6.5−7.257, SP3+ 18, 19, 29 ;
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ IBM: 24P0960 (QLA2340)1, 2, 3, 59,
v2.6.5−7.282 24P8053 (QLA2342)1, 2, 3, 39M5894
(QLA2460)1, 2, 26, 39M5895
(QLA2462)1, 2, 26;
QLogic: QLA2460−E−SP1, 2, 26,
QLE2360−E−SP1, 2, 35,
QLE2460−E−SP1, 2, 26
53 Dell PowerEdge: 1850, 1900, 2850, 2900, 2950, SuSE SLES [32−Bit] 9: SP3 PCI QLogic QLE220−E−SP2, 14, 17 FC−AL, EMC Y
6800, 6850, 6950; v2.6.5−7.244, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX150
Digital Henge Revo: AS1500, AS1550, AS2500; v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
Intel: SR1500/S5000PAL, SR2500/S5000PAL v2.6.5−7.276, SP3+
v2.6.5−7.282
54 Fujitsu Siemens Primergy: RX200 S3, RX220, SuSE SLES [32−Bit] 9: SP3 PCI QLogic: QLA2340−E−SP1, 2, 3, FC−AL, EMC Y
RX600 S3, TX300 S3, TX600 S3 v2.6.5−7.244, SP3+ Express, QLA2340−E−SP1, 3, QLA2340−E−SP2, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 3, QLA2340−E−SP3 AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 347 CLARiiON AX150


CLARiiON AX150

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
55 HPQ Proliant BL460c: (416653−B21), SuSE SLES [32−Bit] 9: SP3 PCI−X HPQ Emulex LPe1105−HP 4Gb FC FC−AL, EMC Y21, 22
(416654−B21), (416655−B21), (416656−B21), v2.6.5−7.244, SP3+ HBA for HP c−Class Bladesystem FC−SW CLARiiON
(432636−B21); v2.6.5−7.252, SP3+ (403621−B21)18, 29, 30 AX150
v2.6.5−7.257, SP3+
HPQ Proliant BL480c: (416666−B21), v2.6.5−7.267, SP3+
(416667−B21), (416668−B21), (416669−B21) v2.6.5−7.276, SP3+
v2.6.5−7.282
56 HPQ Proliant BL460c: (416653−B21), SuSE SLES [32−Bit] 9: SP3 PCI−X HPQ QLogic QMH2462 4Gb FC HBA FC−AL, EMC N
(416654−B21), (416655−B21), (416656−B21), v2.6.5−7.244, SP3+ for HP c−Class Bladesystem FC−SW CLARiiON
(432636−B21); v2.6.5−7.252, SP3+ (403619−B21)15, 16 AX150
v2.6.5−7.257, SP3+
HPQ Proliant BL480c: (416666−B21), v2.6.5−7.267, SP3+
(416667−B21), (416668−B21), (416669−B21) v2.6.5−7.276, SP3+
v2.6.5−7.282
57 Dell PowerEdge: 1800, 2800 SuSE SLES [32−Bit] 9: SP3 PCI, PCI QLogic QLE220−E−SP2, 14, 17 FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
58 Fujitsu Siemens Primergy TX200 S3 SuSE SLES [32−Bit] 9: SP3 PCI, PCI QLogic: QLA2340−E−SP1, 2, 3, FC−AL, EMC Y
v2.6.5−7.244, SP3+ Express, QLA2340−E−SP1, 3, QLA2340−E−SP2, FC−SW CLARiiON
v2.6.5−7.252, SP3+ PCI−X 3, QLA2340−E−SP3 AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
59 Fujitsu Siemens Primergy RX800 S2 SuSE SLES [32−Bit] 9: SP3 PCI, Emulex LP1050−E2, 18, 19, 45 ; FC−AL, EMC Y
v2.6.5−7.244, SP3+ PCI−X QLogic: QLA2340−E−SP1, 2, 3, FC−SW CLARiiON
v2.6.5−7.252, SP3+ QLA2340−E−SP1, 3, QLA2340−E−SP2, AX150
v2.6.5−7.257, SP3+ 3, QLA2340−E−SP3
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
60 Unisys ES7000/460 [32−Bit] SuSE SLES [32−Bit] 9: SP3 PCI, Unisys: FCH732213−P64 FC−AL, EMC Y4
v2.6.5−7.244, SP3+ PCI−X (LP9002L−F2)18, 19, 40, FC−SW CLARiiON
v2.6.5−7.252, SP3+ FCH742313−P64 (LP9802)18, 19, 36, AX150
v2.6.5−7.257, SP3+ FCH752313−PCX (LP1050)18, 19, 36
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
61 Fujitsu Siemens Primergy BX630: (2−way), (4−way) SuSE SLES [32−Bit] 9: SP3 PCI Emulex LP1050−E2, 18, 19, 45 FC−AL, EMC Y
v2.6.5−7.2445, 6, 9, SP3+ FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
62 Fujitsu Siemens Primergy: BX620 S3, BX630 SuSE SLES [32−Bit] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q1, 2, 3, FC−AL, EMC Y
(2−way), BX630 (4−way), BX630 (8−way) v2.6.5−7.2445, 6, 9, SP3+ 28 FC−SW CLARiiON
v2.6.5−7.252, SP3+ AX150
v2.6.5−7.257, SP3+
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+
v2.6.5−7.282
63 Bull NovaScale 2320 SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
port: for NovaScale Blade Series CLARiiON
CFSN202−110010, 11, mini for AX150
NovaScale Blade 2021
CFSN202−210010, 11;
Bull SBEFCM (SFF) Mezzanine: HBA2,
11, 58, 61 , HBA2, 10, 11;

Bull SBEFCM4 (SFF) 4Gb Mezzanine


HBA11, 12
64 Digital Henge PowerBlade BS200L SuSE SLES [32−Bit] 105, 6, 7, 8, 9 PCI−X Digital Henge Digital Henge: FC−SW EMC Y
SBEFCM42, 11, 12, SBEFCM10, 11, CLARiiON
SBFCM10, 11; AX150
Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD2, 10, 11
65 IBM BladeCenter HS20 (Model: 7981), 8678)39, SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20 FC Exp Card: (13N2203)2, 3, FC−SW EMC Y21, 22
8832)39, 8832−N1X), 8843); v2.6.5−7.201, v2.6.5−7.202.7 32, (48P7061)2, 3, 32 CLARiiON
AX150
IBM BladeCenter HS40 (Model 8839)
66 IBM BladeCenter HS20 (Model 8843) SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 (26R0890)2, 27, 37, FC Exp Card CLARiiON
(26K4841)2, 3, 32 AX150
67 IBM BladeCenter LS20 (Model 8850) SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card FC−SW EMC Y21, 22
v2.6.5−7.201, v2.6.5−7.202.7 (26R0890)2, 32, 37, FC Exp Card CLARiiON
(13N2203) for IBM eServer LS202, 3, 32, AX150
FC SFF Exp Card (26K4841) for IBM
eServer LS202, 3, 32
68 IBM BladeCenter HS20 (Model: 7981), 8678)39, SuSE SLES [32−Bit] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp Card2, FC−SW EMC Y21, 22
8832)39, 8832−N1X), 8843); v2.6.5−7.201, v2.6.5−7.202.7 19, 24, 47 , HS20 4GB Standard FC Exp CLARiiON
Card (26R0884)2, 32, 38 AX150
IBM BladeCenter: HS40 (Model 8839), LS20 (Model
8850)
69 Bull NovaScale 2320; SuSE SLES [32−Bit] 9: SP3 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
Digital Henge PowerBlade BS200L v2.6.5−7.244, SP3+ port: for NovaScale Blade Series CLARiiON
v2.6.5−7.252, SP3+ CFSN202−11001, 10, mini for AX150
v2.6.5−7.257, SP3+ NovaScale Blade 2021
v2.6.5−7.267, SP3+ CFSN202−21001, 10
v2.6.5−7.276, SP3+
v2.6.5−7.282

11/02/2006 348 CLARiiON AX150


CLARiiON AX150

SuSE SLES [32−Bit]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
70 Bull NovaScale 2320 SuSE SLES [32−Bit] 9: SP3 PCI−X Bull 2Gbps FC Mezzanine Card − Dual FC−SW EMC Y
v2.6.5−7.244, SP3+ port: for NovaScale Blade Series CLARiiON
v2.6.5−7.252, SP3+ CFSN202−110058, mini for NovaScale AX150
v2.6.5−7.257, SP3+ Blade 2021 CFSN202−210010;
v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ Bull SBEFCM (SFF) Mezzanine: HBA1,
v2.6.5−7.282 10, HBA58;

Bull SBEFCM4 (SFF) 4Gb Mezzanine


HBA1, 12
71 Digital Henge PowerBlade BS200L SuSE SLES [32−Bit] 9: SP3 PCI−X Bull SBEFCM (SFF) Mezzanine HBA1, FC−SW EMC Y
v2.6.5−7.244, SP3+ 2, 10; CLARiiON
v2.6.5−7.252, SP3+ Digital Henge Digital Henge: AX150
v2.6.5−7.257, SP3+ SBEFCM41, 2, 12, SBEFCM1, 10,
v2.6.5−7.267, SP3+ SBFCM1, 10;
v2.6.5−7.276, SP3+
v2.6.5−7.282 Digital Henge Intel (r) Fibre Channel
Module AHWFCMOD1, 2, 10
1. Driver Version 8.01.02−sles Driver is integrated into the kernel.
2. SNIA HBA API Supported.
3. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. PowerPath is not supported.
5. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
6. Novell OES is supported on this kernel.
7. Native multipathing is not supported on boot−from−SAN configurations.
8. Supported kernels: 2.6.16.21−0.8.
Confirm kernel support with server vendor.
9. SGI's XFS filesystem is supported.
10. BIOS 1.43 Supports BIOS 1.43. Available at http://www.qlogic.com
11. Driver Version 8.01.04−k Driver is integrated into the kernel.
12. BIOS 1.12 Requires BIOS 1.12 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
14. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
15. BIOS 1.16
16. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
18. Driver Version 8.0.16.17 Driver is integrated into the kernel.
19. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
20. Firmware Version 1.91a5
21. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
22. VxVM is not supported on servers booting from the array.
23. Firmware Version 2.50a6
24. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
25. Driver Version 8.0.16.6_p3
26. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Driver Version 8.01.00
28. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
29. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
31. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
34. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
35. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
37. BIOS 1.12
38. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
39. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
40. Firmware Version 3.92a2 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
41. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
42. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
43. Accepts PCI−X 1.0 and 2.0 HBAs.
44. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
45. Firmware Version 1.91a1
46. Driver Version 8.1.6 Driver is integrated into the kernel.
47. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
48. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
49. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
50. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
51. Driver Version 8.01.04−k
52. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
53. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
54. Driver Version 8.1.6
55. Firmware Version 2.50a8
56. BIOS 6.00a1
57. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
58. BIOS 1.43
59. This HBA is equivalent to the QLogic QLA2340.
60. Firmware Version 2.10a10
61. EMC recommends upgrading to the most recent, EMC−Approved, HBA driver.
62. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

SuSE SLES [AMD−64]

11/02/2006 349 CLARiiON AX150


CLARiiON AX150

SuSE SLES [AMD−64]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 IBM eServer 326m SuSE SLES [AMD−64] 9 SP2+: PCI Emulex: LP1050Ex−E3, 4, 5, 7, LPe111−E3, 4, 17, 42 , FC−AL, EMC Y2, 36
(Model 7969) v2.6.5−7.201, v2.6.5−7.20137, 38, Express, LPe1150−E3, 4, 28, 35 ; FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX150
QLogic: QLE2360−E−SP3, 12, 13, 14 , QLE2460−E−SP3, 10, 12
2 HPQ Proliant: SuSE SLES [AMD−64] 9 SP2+: PCI, Emulex: LP101−E3, 4, 7, 40, LP1050−E4, 6, 40, LP982−E4, 40 FC−AL, EMC Y2
DL14525, DL38525, v2.6.5−7.201, v2.6.5−7.20137, 38, PCI−X FC−SW CLARiiON
DL58525 v2.6.5−7.202.7 AX150
3 HPQ Proliant: SuSE SLES [AMD−64] 9 SP2+: PCI, QLogic: QLA200−E−SP3, 26, 39, QLA210−E−SP3, 12, 26, FC−AL, EMC Y1, 2
DL14525, DL38525, v2.6.5−7.201, v2.6.5−7.20137, 38, PCI−X QLA2340−E−SP11, 39 FC−SW CLARiiON
DL58525 v2.6.5−7.202.7 AX150
4 Dell PowerEdge 6950 SuSE SLES [AMD−64] 9 SP2+: PCI Emulex: LP101−E3, 4, 5, 7, LP1050−E3, 4, 5, 6, LP1050Ex−E3, 4, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.202.7 Express, 5, 7, LP982−E3, 4, 5, LPe111−E3, 4, 17, 42 , LPe1150−E3, 4, 28, FC−SW CLARiiON
PCI−X 35; AX150
QLogic: QLA2340−E−SP3, 11, 12, QLE2360−E−SP3, 12, 13, 14 ,
QLE2460−E−SP3, 10, 12
5 IBM xSeries x3455 SuSE SLES [AMD−64] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 7, 16; FC−AL, EMC Y, Y8
(7984) v2.6.5−7.244, SP3+ v2.6.5−7.252, Express IBM: 42C2069 (LPe11000)3, 4, 16, 34 , 42C2071 (LPe11002)3, 4, FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ 16, 34; AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282 QLogic: QLE2360−E−SP3, 9, 14, QLE2460−E−SP3, 9, 10
6 HPQ Proliant BL465c: SuSE SLES [AMD−64] 9: SP3 PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y1, 2,
(403433−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, Express Bladesystem (403621−B21)16, 20, 21 FC−SW CLARiiON Y22
(403434−B21), SP3+ v2.6.5−7.257, SP3+ AX150
(407234−B21), v2.6.5−7.267, SP3+ v2.6.5−7.276,
(407235−B21) SP3+ v2.6.5−7.282
7 HPQ Proliant BL465c: SuSE SLES [AMD−64] 9: SP3 PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(403433−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, Express Bladesystem (403619−B21)9, 15 FC−SW CLARiiON
(403434−B21), SP3+ v2.6.5−7.257, SP3+ AX150
(407234−B21), v2.6.5−7.267, SP3+ v2.6.5−7.276,
(407235−B21) SP3+ v2.6.5−7.282
8 HPQ Proliant BL465c: SuSE SLES [AMD−64] 9: SP3 PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y
(403433−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, Express Bladesystem (403621−B21)16, 20, 21, QLogic QMH2462 4Gb FC−SW CLARiiON
(403434−B21), SP3+ v2.6.5−7.257, SP3+ FC HBA for HP c−Class Bladesystem (403619−B21)9, 15 AX150
(407234−B21), v2.6.5−7.267, SP3+ v2.6.5−7.276,
(407235−B21) SP3+ v2.6.5−7.282
9 Dell PowerEdge 6950; SuSE SLES [AMD−64] 9: SP3 PCI Emulex LP1050Ex−E3, 4, 7, 16; FC−AL, EMC Y
IBM: eServer 326m v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, QLogic QLE2460−E−SP3, 9, 10 FC−SW CLARiiON
(Model 7969), xSeries SP3+ v2.6.5−7.257, SP3+ PCI−X AX150
x3755 (8877) v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
10 Dell PowerEdge 6950; SuSE SLES [AMD−64] 9: SP3 PCI Emulex: LP101−E3, 4, 7, 16, LP1050−E3, 4, 6, 16, LP982−E3, 4, FC−AL, EMC Y
IBM xSeries x3755 v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, 16; FC−SW CLARiiON
(8877) SP3+ v2.6.5−7.257, SP3+ PCI−X AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276, QLogic QLA2340−E−SP3, 9, 11
SP3+ v2.6.5−7.282
11 IBM xSeries x3755 SuSE SLES [AMD−64] 9: SP3 PCI Emulex: LP1050−E3, 4, 6, 16, LP1050Ex−E3, 4, 7, 16, FC−AL, EMC Y8
(8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, LP1150−E3, 4, 16, 27 , LP982−E3, 4, 16, LPe111−E3, 4, 16, 17 , FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ PCI−X LPe1150−E3, 4, 16, 28 ; AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282 IBM: 24P0960 (QLA2340)3, 9, 11, 19 , 24P8053 (QLA2342)3, 9,
11,39M5894 (QLA2460)3, 9, 10, 39M5895 (QLA2462)3, 9, 10;
QLogic: QLA2340−E−SP3, 9, 11, QLA2460−E−SP3, 9, 10,
QLE2360−E−SP3, 9, 14, QLE2460−E−SP3, 9, 10
12 Dell PowerEdge 6950; SuSE SLES [AMD−64] 9: SP3 PCI Emulex: LPe111−E3, 4, 16, 17 , LPe1150−E3, 4, 16, 28 ; FC−AL, EMC Y
IBM eServer 326m v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, FC−SW CLARiiON
(Model 7969) SP3+ v2.6.5−7.257, SP3+ PCI−X QLogic QLE2360−E−SP3, 9, 13, 14 AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
13 IBM xSeries x3755 SuSE SLES [AMD−64] 9: SP3 PCI IBM: 24P0960 (QLA2340)3, 11, 18, 19 , 24P8053 (QLA2342)3, FC−AL, EMC Y
(8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, 11, 18, 39M5894 (QLA2460)3, 9, 10, 39M5895 (QLA2462)3, 9, FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ PCI−X 10; AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282 QLogic: QLA2460−E−SP3, 9, 10, QLE2360−E−SP3, 9, 14
14 Dell PowerEdge 6950 SuSE SLES [AMD−64] 9: SP3 PCI QLogic QLE220−E−SP3, 29, 30 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, Express, FC−SW CLARiiON
SP3+ v2.6.5−7.257, SP3+ PCI−X AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
15 HPQ Proliant: SuSE SLES [AMD−64] 9: SP3 PCI, Emulex: LP101−E3, 4, 7, 16, LP1050−E4, 6, 16, LP982−E4, 16; FC−AL, EMC Y
DL14525, DL38525, v2.6.5−7.244, SP3+ v2.6.5−7.252, PCI−X FC−SW CLARiiON
DL58525 SP3+ v2.6.5−7.257, SP3+ QLogic: QLA200−E−SP3, 9, 26, QLA210−E−SP3, 9, 26, AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276, QLA2340−E−SP9, 11, QLE220−E−SP3, 29, 30, 41
SP3+ v2.6.5−7.282
16 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9 SP2+: PCI−X IBM HS20 4GB: SFF FC Exp Card (26R0890)3, 12, 33, FC−SW EMC Y1, 2
(Model 8850) v2.6.5−7.201, v2.6.5−7.20137, 38, Standard FC Exp Card (26R0884)3, 12, 32 CLARiiON
v2.6.5−7.202.7 AX150
17 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 5, 31, HS20 FC Exp FC−SW EMC Y2
(Model 8850) v2.6.5−7.201, v2.6.5−7.20137, 38, Card (13N2203) for IBM eServer LS203, 11, 12, HS20 FC SFF CLARiiON
v2.6.5−7.202.7 Exp Card (26K4841) for IBM eServer LS203, 11, 12 AX150
18 IBM BladeCenter: LS20 SuSE SLES [AMD−64] 9: SP3 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)3, FC−SW EMC Y
(Model 8850), LS21 v2.6.5−7.244, SP3+ v2.6.5−7.252, 16, 23, 24 , HS20 4GB SFF FC Exp Card (26R0890)3, 9, 33 CLARiiON
(Model 7971), LS41 SP3+ v2.6.5−7.257, SP3+ AX150
(Model 7972) v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
19 IBM BladeCenter LS20 SuSE SLES [AMD−64] 9: SP3 PCI−X IBM: Emulex LP1005DC FC Exp Card3, 4, 16, 31 , HS20 4GB FC−SW EMC Y
(Model 8850) v2.6.5−7.244, SP3+ v2.6.5−7.252, Standard FC Exp Card (26R0884)3, 9, 32, HS20 FC Exp Card CLARiiON
SP3+ v2.6.5−7.257, SP3+ (13N2203) for IBM eServer LS203, 9, 11, HS20 FC SFF Exp AX150
v2.6.5−7.267, SP3+ v2.6.5−7.276, Card (26K4841) for IBM eServer LS203, 9, 11
SP3+ v2.6.5−7.282

11/02/2006 350 CLARiiON AX150


CLARiiON AX150

1. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
2. VxVM is not supported on servers booting from the array.
3. SNIA HBA API Supported.
4. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
5. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
6. Firmware Version 1.91a5
7. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
8. PowerPath is not supported.
9. Driver Version 8.01.02−sles Driver is integrated into the kernel.
10. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.16
16. Driver Version 8.0.16.17 Driver is integrated into the kernel.
17. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
18. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. This HBA is equivalent to the QLogic QLA2340.
20. Firmware Version 2.50a8
21. BIOS 6.00a1
22. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
23. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
24. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
25. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
26. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Firmware Version 2.10a10
28. Firmware Version 2.50a6
29. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
30. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
31. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
33. BIOS 1.12
34. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
35. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
36. Booting from the SAN with PowerPath is not supported.
37. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
38. SGI's XFS filesystem is supported.
39. Driver Version 8.01.00
40. Driver Version 8.0.16.6_p3
41. Driver/BIOS are available at http://www.qlogic.com
42. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

SuSE SLES [EM64T]

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex LP1050−E3, 6, 46, 49 ; FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.5−7.201, v2.6.5−7.20120, 21, Fujitsu Siemens BX600−FC22Q6, 12, 33, 40 FC−SW CLARiiON
v2.6.5−7.202.7 AX150
2 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LP1050Ex−E3, 6, 9, 11; FC−AL, EMC Y1, 2
1950, 2800, 2850, 6800, v2.6.5−7.201, v2.6.5−7.20120, 21, Express QLogic QLE2360−E−SP6, 7, 15, 16 FC−SW CLARiiON
6850; v2.6.5−7.202.7 AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)39;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
3 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LPe111−E3, 6, 24, 46 FC−AL, EMC Y1, 2
1950, 2800, 2850, 6800, v2.6.5−7.201, v2.6.5−7.20120, 21, Express FC−SW CLARiiON
6850; v2.6.5−7.202.7 AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
HPQ Proliant: DL360(G4)14,
DL380(G4)14, DL580(G3)14,
ML350(G4)14, ML370(G4)14;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230

11/02/2006 351 CLARiiON AX150


CLARiiON AX150

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
4 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LPe1150−E3, 4, 5, 6; FC−AL, EMC Y1, 2
1950, 2800, 2850, 6800, v2.6.5−7.201, v2.6.5−7.20120, 21, Express QLogic QLE2460−E−SP6, 7, 8 FC−SW CLARiiON
6850; v2.6.5−7.202.7 AX150
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
5 HPQ Proliant: DL360(G4)14, SuSE SLES [EM64T] 9 SP2+: PCI Emulex LPe1150−E3, 4, 6, 23; FC−AL, EMC Y1, 2
DL380(G4)14, DL580(G3)14, v2.6.5−7.201, v2.6.5−7.20120, 21, Express HPQ A8002A/FC2142SR (LPe1150)3, 6, 9, 31 FC−SW CLARiiON
ML350(G4)14, ML370(G4)14 v2.6.5−7.202.7 AX150
6 HPQ Proliant ML350(G4)14 SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP101−E3, 6, 11, 23 , LP1050−E3, 10, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, Express, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX150
HPQ: AB429A/FC1143 (QLA2460)6, 7, 13,
AE369A/FC1243 (QLA2462)6, 7, 13;
QLogic: QLA200−E−SP6, 7, 22, QLA210−E−SP6, 7, 22,
QLA2340−E−SP7, 12
7 Dell PowerEdge: 2900, 2950 SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, Express, LP1050Ex−E3, 6, 9, 11, LP982−E3, 6, 9, LPe111−E3, 6, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X 24, 46, LPe1150−E3, 4, 5, 6; AX150
QLogic: QLA2340−E−SP6, 7, 12, QLE2360−E−SP6, 7,
15, 16, QLE2460−E−SP6, 7, 8

8 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI Emulex: LP1050Ex−E3, 6, 9, LPe1150−E3, 4, 6, FC−AL, EMC Y1, 2
RX220 v2.6.5−7.201, v2.6.5−7.20120, 21, Express, LPe1150−E3, 4, 6, 23 FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX150
9 Dell PowerEdge 1855; SuSE SLES [EM64T] 9 SP2+: PCI−X Dell 2342M7, 12 FC−AL, EMC Y1, 2
Unisys ES3105 v2.6.5−7.201, v2.6.5−7.20120, 21, FC−SW CLARiiON
v2.6.5−7.202.7 AX150
10 Dell PowerEdge 1855 SuSE SLES [EM64T] 9 SP2+: PCI−X Dell: LPe1105−M3, 4, 6, 9, QME24626, 7, 35 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, FC−SW CLARiiON
v2.6.5−7.202.7 AX150
11 HPQ Proliant DL360(G4)14 SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 6, 11, 23 , LP1050−E3, 10, 23, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, LP982−E3, 23; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
HPQ: AB429A/FC1143 (QLA2460)6, 7, 13,
AE369A/FC1243 (QLA2462)6, 7, 13;
QLogic: QLA200−E−SP6, 7, 22, QLA210−E−SP6, 7, 22,
QLA2340−E−SP7, 12
12 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9 SP2+: PCI−X Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, LP982−E3, 6, 9; FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.202.7 AX150
IBM xSeries: x336 (8837)39, QLogic QLA2340−E−SP6, 7, 12
x346 (8840)39, x3850/x366
(8863)36, 37;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
13 IBM xSeries: x3800/x260 SuSE SLES [EM64T] 9 SP2+: PCI−X38 Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
(8865)36, 37, v2.6.5−7.201, v2.6.5−7.20120, 21, LP982−E3, 6, 9; FC−SW CLARiiON
x3950/x3950E/x460 (8872, v2.6.5−7.202.7 AX150
8874)36, 37 QLogic QLA2340−E−SP6, 7, 12
14 Dell PowerEdge 1955 SuSE SLES [EM64T] 9 SP2+: PCI, PCI Dell: LPe1105−M3, 4, 6, 9, QME24626, 7, 35 FC−AL, EMC Y1, 2
v2.6.5−7.201, v2.6.5−7.20120, 21, Express, FC−SW CLARiiON
v2.6.5−7.202.7 PCI−X AX150
15 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 6, 9, 11, LP1050−E3, 6, 9, 10, FC−AL, EMC Y1, 2
2600, 2650, 2800, 2850; v2.6.5−7.201, v2.6.5−7.20120, 21, PCI−X LP982−E3, 6, 9; FC−SW CLARiiON
v2.6.5−7.202.7 AX150
Samsung: ES470, ES570, QLogic QLA2340−E−SP6, 7, 12
SS140
16 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9 SP2+: PCI, HPQ: AB429A/FC1143 (QLA2460)6, 7, 13, FC−AL, EMC Y1, 2
ML370(G4)14 v2.6.5−7.201, v2.6.5−7.20120, 21, PCI−X AE369A/FC1243 (QLA2462)6, 7, 13 FC−SW CLARiiON
v2.6.5−7.202.7 AX150
17 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 6, 11, 23 , LP1050−E3, 10, 23, FC−AL, EMC Y1, 2
ML370(G4)14 v2.6.5−7.201, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP6, 7, 22, QLA210−E−SP6, 7, 22,
QLA2340−E−SP7, 12
18 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9 SP2+: PCI, Emulex LP1050−E3, 6, 46, 49 ; FC−AL, EMC Y
RX800 S2 v2.6.5−7.20120, 21, v2.6.5−7.202.7 PCI−X QLogic: QLA2340−E−SP6, 7, 12, QLA2340−E−SP7, 12 FC−SW CLARiiON
AX150

11/02/2006 352 CLARiiON AX150


CLARiiON AX150

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
19 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9 SP2+: PCI, Emulex: LP101−E3, 6, 11, 23 , LP1050−E3, 10, 23, FC−AL, EMC Y1, 2
DL580(G3)14, ML370(G4)14 v2.6.5−7.20120, 21, v2.6.5−7.202.7 PCI−X LP982−E3, 23; FC−SW CLARiiON
AX150
QLogic: QLA200−E−SP6, 7, 22, QLA210−E−SP6, 7, 22,
QLA2340−E−SP7, 12
20 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050−E3, 6, 19, 49 FC−AL, EMC Y
BX630: (2−way), (4−way) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
21 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI Fujitsu Siemens BX600−FC22Q6, 12, 17, 40 FC−AL, EMC Y
BX620 S3, BX630 (2−way), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
BX630 (4−way), BX630 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
(8−way) v2.6.5−7.276, SP3+ v2.6.5−7.282
22 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 6, 11, 19 ; FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express QLogic QLE2360−E−SP6, 15, 16, 17 FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
IBM xSeries x336 (8837)39;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
23 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI Emulex: LPe111−E3, 6, 19, 24 , LPe1150−E3, 4, 6, 19 FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
HPQ Proliant: DL360(G4)14,
DL380(G4)14, DL580(G3)14,
ML350(G4)14, ML370(G4)14;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
24 HPQ Proliant: DL360(G4)14, SuSE SLES [EM64T] 9: SP3 PCI HPQ A8002A/FC2142SR (LPe1150)3, 6, 19, 31 FC−AL, EMC Y
DL380(G4)14, DL580(G3)14, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
ML350(G4)14, ML370(G4)14 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
25 Dell PowerEdge 1950 SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE220−E−SP6, 28, 29 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
26 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE2460−E−SP6, 8, 17 FC−AL, EMC Y
1950, 2800, 2850, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge INNO:
HR−4850, HR−6850;
Digital Henge Revo: JS1400,
JS2400;
LangChao: NC3000, NC3500,
NF520;
Lenovo SureServer: R650,
T650;
Samsung: ZSS150, ZSS230
27 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI QLogic: QLA2340−E−SP12, 17, QLA2340−E−SP6, 12, FC−AL, EMC Y
RX300 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express 17 FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
28 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LP1050Ex−E3, 6, 19 FC−AL, EMC Y, Y18
RX220 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
29 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe111−E3, 6, 19, 24 ; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, QLogic QLE2360−E−SP6, 15, 16, 17 FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
30 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe1150−E3, 4, 6, 19 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Fujitsu Siemens Primergy
RX220;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL

11/02/2006 353 CLARiiON AX150


CLARiiON AX150

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
31 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI Emulex LPe1150−E3, 4, 6, 19 FC−AL, EMC Y18
RX220; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
IBM xSeries: x3550 (7978), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
x3650 (7979), x3755 (8877) v2.6.5−7.276, SP3+ v2.6.5−7.282
32 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP101−E3, 6, 11, 19 , LP1050−E3, 6, 10, 19 , FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, LP1050Ex−E3, 6, 11, 19 , LP982−E3, 6, 19; FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282 QLogic QLE2460−E−SP6, 8, 17
IBM xSeries: x3550 (7978),
x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
33 HPQ Proliant ML350(G4)14 SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP101−E3, 6, 11, LP1050−E3, 10, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: AB429A/FC1143 (QLA2460)6, 13, 17, AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)6, 13, 17;
QLogic: QLA200−E−SP6, 17, 22, QLA210−E−SP6, 17,
22, QLE220−E−SP6, 27, 28, 29

34 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI Emulex: LP1050Ex−E3, 6, 11, 19 , LP1150−E3, 6, 19, 30 , FC−AL, EMC Y18
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, LPe111−E3, 6, 19, 24 ; FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 IBM: 24P0960 (QLA2340)6, 12, 17, 26 , 24P8053
(QLA2342)6, 12, 17, 39M5894 (QLA2460)6, 8, 17,
39M5895 (QLA2462)6, 8, 17;
QLogic: QLA2460−E−SP6, 8, 17, QLE2360−E−SP6,
15, 17, QLE2460−E−SP6, 8, 17

35 IBM xSeries: x3550 (7978), SuSE SLES [EM64T] 9: SP3 PCI IBM: 24P0960 (QLA2340)6, 12, 25, 26 , 24P8053 FC−AL, EMC Y
x3650 (7979), x3755 (8877) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, (QLA2342)6, 12, 25, 39M5894 (QLA2460)6, 8, 17, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X 39M5895 (QLA2462)6, 8, 17; AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
QLogic: QLA2460−E−SP6, 8, 17, QLE2360−E−SP6,
15, 17

36 Fujitsu Siemens Primergy: SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP12, 17 FC−AL, EMC Y
RX200 S3, RX220, RX600 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
S3, TX300 S3, TX600 S3; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
HPQ Proliant ML350(G4)14
37 Dell PowerEdge: 2900, 2950; SuSE SLES [EM64T] 9: SP3 PCI QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
AS1550, AS2500; v2.6.5−7.276, SP3+ v2.6.5−7.282
Fujitsu Siemens Primergy:
RX200 S3, RX220, RX600
S3, TX300 S3, TX600 S3;
IBM xSeries: x3550 (7978),
x3650 (7979), x3755 (8877);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
38 Dell PowerEdge: 1850, 1900, SuSE SLES [EM64T] 9: SP3 PCI QLogic QLE220−E−SP6, 28, 29 FC−AL, EMC Y
2850, 2900, 2950, 6800, v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
6850; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
Digital Henge Revo: AS1500,
AS1550, AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
39 Dell PowerEdge 1855; SuSE SLES [EM64T] 9: SP3 PCI−X Dell 2342M12, 17 FC−AL, EMC Y
Unisys ES3105 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
40 Dell PowerEdge 1855 SuSE SLES [EM64T] 9: SP3 PCI−X Dell: LPe1105−M3, 4, 6, 19, QME24626, 17, 35 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
41 IBM xSeries x3850/x366 SuSE SLES [EM64T] 9: SP3 PCI−X Emulex LP9802−E3, 6, 11, 19 FC−AL, EMC Y
(8863)36, 37 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
42 Dell PowerEdge: 6800, 6850; SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 6, 11, 19 , LP1050−E3, 6, 10, 19 , FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ LP982−E3, 6, 19 FC−SW CLARiiON
Digital Henge SH4500R4; v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
IBM xSeries: x336 (8837)39, v2.6.5−7.276, SP3+ v2.6.5−7.282
x346 (8840)39, x3850/x366
(8863)36, 37;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230

11/02/2006 354 CLARiiON AX150


CLARiiON AX150

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
43 HPQ Proliant DL360(G4)14 SuSE SLES [EM64T] 9: SP3 PCI−X Emulex: LP101−E3, 6, 11, LP1050−E3, 10, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ HPQ: AB429A/FC1143 (QLA2460)6, 13, 17, AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)6, 13, 17;
QLogic: QLA200−E−SP6, 17, 22, QLA210−E−SP6, 17,
22, QLA2340−E−SP12, 17, QLE220−E−SP6, 27, 28, 29

44 HPQ Proliant BL460c: SuSE SLES [EM64T] 9: SP3 PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−AL, EMC Y1, 2
(416653−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ c−Class Bladesystem (403621−B21)19, 24, 47 FC−SW CLARiiON
(416654−B21), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
(416655−B21), v2.6.5−7.276, SP3+ v2.6.5−7.282
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21), (416669−B21)
45 HPQ Proliant BL460c: SuSE SLES [EM64T] 9: SP3 PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−AL, EMC N
(416653−B21), v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Bladesystem (403619−B21)25, 45 FC−SW CLARiiON
(416654−B21), v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
(416655−B21), v2.6.5−7.276, SP3+ v2.6.5−7.282
(416656−B21),
(432636−B21);
HPQ Proliant BL480c:
(416666−B21),
(416667−B21),
(416668−B21), (416669−B21)
46 Dell PowerEdge: 1950, 6800, SuSE SLES [EM64T] 9: SP3 PCI−X QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
6850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
Digital Henge SH4500R4; v2.6.5−7.276, SP3+ v2.6.5−7.282
IBM xSeries: x336 (8837)39,
x346 (8840)39, x3850/x366
(8863)36, 37;
LangChao: NC2000, NC3000,
NC3500, NF420, NF500,
NF520;
Lenovo SureServer R630:
6003, 6004;
Lenovo SureServer: R650,
T630 6003, T650;
Samsung: SS210, SS370,
SS3840, ZSS150, ZSS230
47 Dell PowerEdge 1955 SuSE SLES [EM64T] 9: SP3 PCI, PCI Dell: LPe1105−M3, 4, 6, 19, QME24626, 17, 35 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
48 HPQ Proliant DL380(G5) SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LP101−E3, 6, 11, LP1050−E3, 10, LP982−E3; FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: AB429A/FC1143 (QLA2460)6, 13, 17, AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)6, 13, 17;
QLogic: QLA200−E−SP6, 17, 22, QLA210−E−SP6, 17,
22, QLE220−E−SP6, 27, 28, 29

49 HPQ Proliant: DL380(G5), SuSE SLES [EM64T] 9: SP3 PCI, PCI Emulex: LPe111−E3, 6, 19, 24 , LPe1150−E3, 4, 6, 19; FC−AL, EMC Y
DL580(G4) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X HPQ: A8002A/FC2142SR (LPe1150)3, 6, 19, 31 , AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE311A/FC1142SR (QLE2460)6, 8, 44,
AE312A/FC1242SR (QLE2462)6, 8, 17;
QLogic: QLE2460−E−SP6, 8, 17, QLE2462−E−SP6, 8,
17

50 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLA2340−E−SP12, 17 FC−AL, EMC Y
TX200 S3; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
HPQ Proliant DL380(G5) v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
51 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
TX200 S3 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
52 Dell PowerEdge: 1800, 2800 SuSE SLES [EM64T] 9: SP3 PCI, PCI QLogic QLE220−E−SP6, 28, 29 FC−AL, EMC Y
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ Express, FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ PCI−X AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
53 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, Emulex LP1050−E3, 6, 19, 49 FC−AL, EMC Y
RX800 S2 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
54 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 6, 11, 19 , LP1050−E3, 6, 10, 19 , FC−AL, EMC Y
2600, 2650, 2800, 2850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X LP982−E3, 6, 19 FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
Samsung: ES470, ES570, v2.6.5−7.276, SP3+ v2.6.5−7.282
SS140
55 HPQ Proliant: DL380(G4)14, SuSE SLES [EM64T] 9: SP3 PCI, Emulex: LP101−E3, 6, 11, LP1050−E3, 10, LP982−E3; FC−AL, EMC Y
ML370(G4)14 v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ HPQ: AB429A/FC1143 (QLA2460)6, 13, 17, AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282 AE369A/FC1243 (QLA2462)6, 13, 17;
QLogic: QLA200−E−SP6, 17, 22, QLA210−E−SP6, 17,
22, QLE220−E−SP6, 27, 28, 29

11/02/2006 355 CLARiiON AX150


CLARiiON AX150

SuSE SLES [EM64T]


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
56 Fujitsu Siemens Primergy SuSE SLES [EM64T] 9: SP3 PCI, QLogic QLA2340−E−SP12, 17 FC−AL, EMC Y
RX800 S2; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
HPQ Proliant: DL380(G4)14, v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
ML370(G4)14 v2.6.5−7.276, SP3+ v2.6.5−7.282
57 Dell PowerEdge: 1800, 1850, SuSE SLES [EM64T] 9: SP3 PCI, QLogic QLA2340−E−SP6, 12, 17 FC−AL, EMC Y
2600, 2650, 2800, 2850; v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ PCI−X FC−SW CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
Fujitsu Siemens Primergy v2.6.5−7.276, SP3+ v2.6.5−7.282
RX800 S2;
Samsung: ES470, ES570,
SS140
58 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP2+: PCI−X IBM HS20: 4GB SFF FC Exp Card (26R0890)6, 32, FC−SW EMC Y1, 2
(Model 8843) v2.6.5−7.201, v2.6.5−7.20120, 21, 33, FC Exp Card (26K4841)6, 7, 12 CLARiiON
v2.6.5−7.202.7 AX150
59 IBM BladeCenter HS20 SuSE SLES [EM64T] 9 SP2+: PCI−X IBM: Emulex LP1005DC FC Exp Card3, 6, 9, 41, HS20 FC−SW EMC Y1, 2
(Model: 8832−N1X), 8843) v2.6.5−7.201, v2.6.5−7.20120, 21, 4GB Standard FC Exp Card (26R0884)6, 7, 34, HS20 CLARiiON
v2.6.5−7.202.7 FC Exp Card (13N2203)6, 7, 12, HS20 FC Exp Card AX150
(48P7061)6, 7, 12
60 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM HS20 FC Exp Card (26K4841)6, 12, 17 FC−SW EMC Y
(Model 8843) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
61 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM HS20 FC Exp Card: (13N2203)6, 12, 17, FC−SW EMC Y
(Model: 8832−N1X), 8843); v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ (48P7061)6, 12, 17 CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
IBM BladeCenter HS21 v2.6.5−7.276, SP3+ v2.6.5−7.282
(Model 8853)48
62 IBM BladeCenter: HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y
(Model 8843), HS21 (Model v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ (39Y9186)6, 19, 42, 43 , HS20 4GB SFF FC Exp Card CLARiiON
8853)48 v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ (26R0890)6, 17, 32 AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
63 IBM BladeCenter HS20 SuSE SLES [EM64T] 9: SP3 PCI−X IBM: Emulex LP1005DC FC Exp Card3, 6, 19, 41 , FC−SW EMC Y
(Model: 8832−N1X), 8843) v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ HS20 4GB Standard FC Exp Card (26R0884)6, 17, 34 CLARiiON
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ AX150
v2.6.5−7.276, SP3+ v2.6.5−7.282
1. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
2. VxVM is not supported on servers booting from the array.
3. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
4. Firmware Version 2.50a6
5. Driver Version 8.0.16.6−p3 Driver is integrated into the kernel.
6. SNIA HBA API Supported.
7. Driver Version 8.01.00 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver Version 8.0.16.6_p3 Driver is integrated into the kernel.
10. Firmware Version 1.91a5
11. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
12. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
15. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 8.01.02−sles Driver is integrated into the kernel.
18. PowerPath is not supported.
19. Driver Version 8.0.16.17 Driver is integrated into the kernel.
20. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
21. SGI's XFS filesystem is supported.
22. BIOS 1.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Driver Version 8.0.16.6_p3
24. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
25. Driver Version 8.01.02−sles Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. This HBA is equivalent to the QLogic QLA2340.
27. Driver/BIOS are available at http://www.qlogic.com
28. Driver Version 8.01.05 Driver/BIOS are available at http://www.qlogic.com
29. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
30. Firmware Version 2.10a10
31. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
32. BIOS 1.12
33. Driver Version 8.01.00
34. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
35. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
37. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
38. Accepts PCI−X 1.0 and 2.0 HBAs.
39. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
40. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
41. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
43. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
44. Driver Version 8.01.02−sles Available in the EMC−approved section of the Emulex website. http://www.emulex.com Driver is integrated into the kernel.
45. BIOS 1.16
46. Driver Version 8.0.16.6_p3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
47. BIOS 6.00a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
48. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
49. Firmware Version 1.91a1

SuSE SLES [x86_64]

11/02/2006 356 CLARiiON AX150


CLARiiON AX150

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
1 Fujitsu Siemens Primergy: BX620 S3, SuSE SLES PCI Emulex LP1050−E10, 11, 12, 13 FC−AL, EMC Y
BX630 (2−way), BX630 (4−way) [x86_64] 101, FC−SW CLARiiON
2, 3, 4 AX150
2 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI Emulex LP1050Ex−E10, 12, 13, 28 ; FC−AL, EMC Y
2800, 2850, 6800, 6850; [x86_64] 101, Express QLogic QLE2360−E−SP12, 18, 19, 20 FC−SW CLARiiON
2, 3, 4 AX150
IBM xSeries x336 (8837)34
3 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI Emulex: LPe111−E10, 12, 13, 29 , LPe1150−E10, 12, 13, 31 FC−AL, EMC Y
2800, 2850, 6800, 6850; [x86_64] 101, Express FC−SW CLARiiON
2, 3, 4 AX150
HPQ Proliant: DL360(G4)23,
DL380(G4)23, DL580(G3)23,
ML350(G4)23, ML370(G4)23
4 HPQ Proliant: DL360(G4)23, SuSE SLES PCI HPQ A8002A/FC2142SR (LPe1150)10, 12, 13, 33 FC−AL, EMC Y
DL380(G4)23, DL580(G3)23, [x86_64] 101, Express FC−SW CLARiiON
ML350(G4)23, ML370(G4)23 2, 3, 4 AX150
5 HPQ Proliant BL465c: (403433−B21), SuSE SLES PCI HPQ Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y26, Y5,
(403434−B21), (407234−B21), [x86_64] 101, Express Bladesystem (403621−B21)7, 8, 9 FC−SW CLARiiON 6
(407235−B21) 2, 3, 4 AX150
6 HPQ Proliant BL465c: (403433−B21), SuSE SLES PCI HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(403434−B21), (407234−B21), [x86_64] 101, Express (403619−B21)16, 17 FC−SW CLARiiON
(407235−B21) 2, 3, 4 AX150
7 HPQ Proliant BL465c: (403433−B21), SuSE SLES PCI HPQ: Emulex LPe1105−HP 4Gb FC HBA for HP c−Class FC−AL, EMC Y
(403434−B21), (407234−B21), [x86_64] 101, Express Bladesystem (403621−B21)7, 8, 9, QLogic QMH2462 4Gb FC HBA FC−SW CLARiiON
(407235−B21) 2, 3, 4 for HP c−Class Bladesystem (403619−B21)16, 17 AX150
8 Dell PowerEdge 1950 SuSE SLES PCI QLogic QLE220−E−SP12, 14, 15 FC−AL, EMC Y
[x86_64] 101, Express FC−SW CLARiiON
2, 3, 4 AX150
9 Dell PowerEdge: 1800, 1850, 1950, SuSE SLES PCI QLogic QLE2460−E−SP12, 19, 22 FC−AL, EMC Y
2800, 2850, 6800, 6850 [x86_64] 101, Express FC−SW CLARiiON
2, 3, 4 AX150
10 Fujitsu Siemens Primergy RX300 S3 SuSE SLES PCI QLogic: QLA2340−E−SP12, 19, 21, QLA2340−E−SP19, 21 FC−AL, EMC Y
[x86_64] 101, Express FC−SW CLARiiON
2, 3, 4 AX150
11 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI Emulex LP101−E10, 12, 13, 28 FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, 2, 3, 4 PCI−X AX150
AS2500;
HPQ Proliant ML350(G4)23;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
12 Fujitsu Siemens Primergy: RX600 S3, SuSE SLES PCI Emulex LP1050Ex−E10, 12, 13, 30 FC−AL, EMC Y
TX600 S3 [x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
13 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI Emulex: LP1050−E10, 12, 13, 27 , LP982−E10, 12, 13 FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, 2, 3, 4 PCI−X AX150
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
14 HPQ Proliant ML350(G4)23 SuSE SLES PCI Emulex: LP1050−E10, 13, 27, LP982−E10, 13; FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X HPQ AB429A/FC1143 (QLA2460)12, 19, 25; AX150
QLogic QLE220−E−SP12, 14, 15, 24
15 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI Emulex: LP1050Ex−E10, 12, 13, 28 , LPe111−E10, 12, 13, 29 , FC−AL, EMC Y
[x86_64] 101, Express, LPe1150−E10, 12, 13, 31 ; FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, 2, 3, 4 PCI−X AX150
AS2500; QLogic: QLE2360−E−SP12, 18, 19, 20 , QLE2460−E−SP12, 19, 22
IBM eServer 326m (Model 7969);
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
16 Dell PowerEdge: 2900, 2950, 6950; SuSE SLES PCI QLogic QLA2340−E−SP12, 19, 21 FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
Digital Henge Revo: AS1500, AS1550, 2, 3, 4 PCI−X AX150
AS2500;
Fujitsu Siemens Primergy: RX200 S3,
RX600 S3, TX300 S3, TX600 S3;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
17 Fujitsu Siemens Primergy: RX200 S3, SuSE SLES PCI QLogic QLA2340−E−SP19, 21 FC−AL, EMC Y
RX600 S3, TX300 S3, TX600 S3; [x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
HPQ Proliant ML350(G4)23
18 Dell PowerEdge: 1850, 1900, 2850, SuSE SLES PCI QLogic QLE220−E−SP12, 14, 15 FC−AL, EMC Y
2900, 2950, 6800, 6850, 6950; [x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
Digital Henge Revo: AS1500, AS1550,
AS2500;
Intel: SR1500/S5000PAL,
SR2500/S5000PAL
19 Dell PowerEdge 1855 SuSE SLES PCI−X Dell: 2342M19, 21, LPe1105−M10, 12, 13, 31 , QME246212, 19, 35 FC−AL, EMC Y
[x86_64] 101, FC−SW CLARiiON
2, 3, 4 AX150

11/02/2006 357 CLARiiON AX150


CLARiiON AX150

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
20 Dell PowerEdge: 6800, 6850; SuSE SLES PCI−X Emulex LP101−E10, 12, 13, 28 FC−AL, EMC Y
[x86_64] 101, FC−SW CLARiiON
HPQ Proliant DL360(G4)23; 2, 3, 4 AX150
IBM xSeries: x336 (8837)34, x346
(8840)34, x3850/x366 (8863)36, 37
21 Fujitsu Siemens Primergy RX600 S2 SuSE SLES PCI−X Emulex LP1050Ex−E10, 12, 13, 30 FC−AL, EMC Y
[x86_64] 101, FC−SW CLARiiON
2, 3, 4 AX150
22 Dell PowerEdge: 6800, 6850; SuSE SLES PCI−X Emulex: LP1050−E10, 12, 13, 27 , LP982−E10, 12, 13 FC−AL, EMC Y
[x86_64] 101, FC−SW CLARiiON
IBM xSeries: x336 (8837)34,x346 2, 3, 4 AX150
(8840)34, x3850/x366 (8863)36, 37
23 HPQ Proliant DL360(G4)23 SuSE SLES PCI−X Emulex: LP1050−E10, 13, 27, LP982−E10, 13; FC−AL, EMC Y
[x86_64] 101, FC−SW CLARiiON
2, 3, 4 HPQ AB429A/FC1143 (QLA2460)12, 19, 25; AX150
QLogic QLE220−E−SP12, 14, 15, 24
24 HPQ Proliant BL460c: (416653−B21), SuSE SLES PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class Bladesystem FC−AL, EMC N
(416654−B21), (416655−B21), [x86_64] 101, (403619−B21)17, 19 FC−SW CLARiiON
(416656−B21), (432636−B21); 2, 3, 4 AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
25 Dell PowerEdge: 1950, 6800, 6850; SuSE SLES PCI−X QLogic QLA2340−E−SP12, 19, 21 FC−AL, EMC Y
[x86_64] 101, FC−SW CLARiiON
Fujitsu Siemens Primergy: RX600 S2, 2, 3, 4 AX150
TX600 S2;
IBM xSeries: x336 (8837)34, x346
(8840)34
26 Fujitsu Siemens Primergy: RX600 S2, SuSE SLES PCI−X QLogic QLA2340−E−SP19, 21 FC−AL, EMC Y
TX600 S2; [x86_64] 101, FC−SW CLARiiON
2, 3, 4 AX150
HPQ Proliant DL360(G4)23
27 IBM xSeries: x3800/x260 (8865)36, 37, SuSE SLES PCI−X38 Emulex: LP101−E10, 12, 13, 28 , LP1050−E10, 12, 13, 27 , LP982−E10, 12, FC−AL, EMC Y
x3950/x3950E/x460 (8872, 8874)36, 37 [x86_64] 101, 13 FC−SW CLARiiON
2, 3, 4 AX150
28 Dell PowerEdge 1955 SuSE SLES PCI, PCI Dell: LPe1105−M10, 12, 13, 31 , QME246212, 19, 35 FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
29 HPQ Proliant: DL380(G5), DL580(G4) SuSE SLES PCI, PCI Emulex: LP101−E10, 12, 13, 28 , LP1050−E10, 13, 27, LP982−E10, 13, FC−AL, EMC Y
[x86_64] 101, Express, LPe111−E10, 12, 13, 29 , LPe1150−E10, 12, 13, 31 ; FC−SW CLARiiON
2, 3, 4 PCI−X AX150
HPQ: A8002A/FC2142SR (LPe1150)10, 12, 13, 33 , AB429A/FC1143
(QLA2460)12, 19, 25, AE311A/FC1142SR (QLE2460)12, 19, 22,
AE312A/FC1242SR (QLE2462)12, 19, 22;
QLogic: QLE220−E−SP12, 14, 15, 24 , QLE2460−E−SP12, 19, 22,
QLE2462−E−SP12, 19, 22
30 Fujitsu Siemens Primergy TX200 S3 SuSE SLES PCI, PCI QLogic QLA2340−E−SP12, 19, 21 FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
31 Fujitsu Siemens Primergy TX200 S3; SuSE SLES PCI, PCI QLogic QLA2340−E−SP19, 21 FC−AL, EMC Y
HPQ Proliant: DL380(G5), DL580(G4) [x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
32 Dell PowerEdge: 1800, 2800 SuSE SLES PCI, PCI QLogic QLE220−E−SP12, 14, 15 FC−AL, EMC Y
[x86_64] 101, Express, FC−SW CLARiiON
2, 3, 4 PCI−X AX150
33 Dell PowerEdge: 1800, 1850, 2600, SuSE SLES PCI, Emulex LP101−E10, 12, 13, 28 FC−AL, EMC Y
2650, 2800, 2850; [x86_64] 101, PCI−X FC−SW CLARiiON
2, 3, 4 AX150
HPQ Proliant: DL380(G4)23, DL38523,
DL58523, ML370(G4)23
34 Dell PowerEdge: 1800, 1850, 2600, SuSE SLES PCI, Emulex: LP1050−E10, 12, 13, 27 , LP982−E10, 12, 13; FC−AL, EMC Y
2650, 2800, 2850 [x86_64] 101, PCI−X FC−SW CLARiiON
2, 3, 4 QLogic QLA2340−E−SP12, 19, 21 AX150
35 HPQ Proliant: DL380(G4)23, DL38523, SuSE SLES PCI, Emulex: LP1050−E10, 13, 27, LP982−E10, 13; FC−AL, EMC Y
DL58523, ML370(G4)23 [x86_64] 101, PCI−X FC−SW CLARiiON
2, 3, 4 QLogic QLA2340−E−SP19, 21 AX150
36 HPQ Proliant: DL380(G4)23, SuSE SLES PCI, HPQ AB429A/FC1143 (QLA2460)12, 19, 25 FC−AL, EMC Y
ML370(G4)23 [x86_64] 101, PCI−X FC−SW CLARiiON
2, 3, 4 AX150
37 HPQ Proliant: DL14523, DL380(G4)23, SuSE SLES PCI, QLogic QLE220−E−SP12, 14, 15, 24 FC−AL, EMC Y
DL38523, DL58523, ML370(G4)23 [x86_64] 101, PCI−X FC−SW CLARiiON
2, 3, 4 AX150
38 IBM BladeCenter: HS20 (Model 8843), SuSE SLES PCI−X IBM HS20 4GB SFF FC Exp Card (26R0890)12, 19, 42 FC−SW EMC Y
LS20 (Model 8850) [x86_64] 101, CLARiiON
2, 3, 4 AX150
39 IBM BladeCenter HS20 (Model: SuSE SLES PCI−X IBM HS20 FC Exp Card: (13N2203)12, 19, 21, (48P7061)12, 19, 21 FC−SW EMC Y
8832−N1X), 8843) [x86_64] 101, CLARiiON
2, 3, 4 AX150
40 IBM BladeCenter LS20 (Model 8850) SuSE SLES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)12, 13, 40, FC−SW EMC Y
[x86_64] 101, 41, HS20 FC Exp Card (13N2203) for IBM eServer LS2012, 19, 21 CLARiiON
2, 3, 4 AX150
41 IBM BladeCenter HS20 (Model 8843) SuSE SLES PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card (39Y9186)12, 13, 41, FC−SW EMC Y
[x86_64] 101, 43, HS20 FC Exp Card (26K4841)12, 19, 21 CLARiiON
2, 3, 4 AX150

11/02/2006 358 CLARiiON AX150


CLARiiON AX150

SuSE SLES [x86_64]


Operating Storage External
No. Host System System Host Bus Host Bus Adapter Topology Array Boot
42 IBM BladeCenter HS20 (Model: SuSE SLES PCI−X IBM: Emulex LP1005DC FC Exp Card10, 12, 13, 32 , HS20 4GB FC−SW EMC Y
8832−N1X), 8843); [x86_64] 101, Standard FC Exp Card (26R0884)12, 19, 39 CLARiiON
2, 3, 4 AX150
IBM BladeCenter LS20 (Model 8850)
1. EMC supports the following filesystems: ext2, ext3, reiserfs. If there is a customer requirement for a different filesystem, please submit an RPQ.
2. Native multipathing is not supported on boot−from−SAN configurations.
3. Supported kernels: 2.6.16.21−0.8.
Confirm kernel support with server vendor.
4. SGI's XFS filesystem is supported.
5. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
6. VxVM is not supported on servers booting from the array.
7. BIOS 6.00a1
8. Driver Version 8.1.6
9. Firmware Version 2.50a8
10. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. Firmware Version 1.91a1
12. SNIA HBA API Supported.
13. Driver Version 8.1.6 Driver is integrated into the kernel.
14. BIOS 1.02 Driver/BIOS are available at http://www.qlogic.com
15. Driver Version 8.01.06 Driver/BIOS are available at http://www.qlogic.com
16. Driver Version 8.01.04−k
17. BIOS 1.16
18. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version 8.01.04−k Driver is integrated into the kernel.
20. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
24. Driver/BIOS are available at http://www.qlogic.com
25. BIOS 1.17 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. Powerpath is supported in boot from SAN configurations for Windows 2003 systems running STORPort drivers (QLogic & Emulex). Windows 2003 servers using STORPort drivers
require a Microsoft STORPort hotfix installed to boot with Powerpath. Please see your driver's requirements for the STORPort hotfix (QFE) version.
27. Firmware Version 1.91a5
28. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
29. Firmware Version 2.50a8 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
30. Firmware Version 1.91a1 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
31. Firmware Version 2.50a6
32. Firmware Version 1.90a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
33. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
34. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
35. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
36. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
37. This system is supported only when the IBM ServeRAID 8i SAS RAID controller (13N227) is installed or when the server is being booted remotely from external storage.
38. Accepts PCI−X 1.0 and 2.0 HBAs.
39. BIOS 1.12 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
40. BIOS 1.71a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
41. Firmware Version 2.10.a10 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. BIOS 1.12
43. BIOS 1.71.a0 Available in the EMC−approved section of the Emulex website. http://www.emulex.com

Sun Solaris

Sun Solaris
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
1 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex: LP10000−E4, 12, 13, 23, 24, 25, 26, 36, 37, 38, 39, 40, 41 , FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris LP9002−E (LP9002L−E)4, 12, 13, 23, 24, 25, 26, 36, 39, 41, 42, 43 , FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 109, 10, 11 LP9802−E4, 12, 13, 23, 24, 25, 26, 36, 37, 38, 39, 40, 41 ; AX150
QLogic QLA2340−E−SP4, 6, 12, 13, 30, 31, 32, 33, 34, 35 ;
Sun: SG−XPCI1FC−EM2 (LP10000)12, 23, 24, 25, 26 ,
SG−XPCI1FC−QL2 (QLA2340)2, 4, 6, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21,
22, X6767A (SG−XPCI1FC−QF2)4, 6, 12, 48

2 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI Emulex LP8000−EMC4, 36, 39, 44, 45, 46, 47 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 1010, 11 AX150
3 Sun Sun Fire: 4800, 6800 Sun PCI Emulex LP9002C−E4, 12, 23, 25, 36, 38, 39, 42, 46, 47 FC−AL, EMC N
Solaris FC−SW CLARiiON
1010, 11 AX150
4 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP1, 3, 5, 6, 13, 28, 30, 31, 32, 33, 35, 49 FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 8 FC−SW CLARiiON
V250, V440, V480, V490, V880, V890 AX150
5 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−QL2 (QLA2340)1, 2, 3, 4, 5, 6 , X6767A FC−AL, EMC N
Solaris 8 (SG−XPCI1FC−QF2)1, 3, 4, 5, 6, 12, 48 FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, AX150
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R8, 250, 420R8, 450
6 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun SG−XPCI1FC−EM2 (LP10000)1, 3, 5, 12, 13, 24, 25, 26, 28 FC−AL, EMC N
Solaris FC−SW CLARiiON
Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, 829 AX150
6800, 6900, V100, V120, V1280, V210, V240,
V250, V440, V480, V490, V880, V890;
Sun Ultra: 220R8, 250, 420R8, 450

11/02/2006 359 CLARiiON AX150


CLARiiON AX150

Sun Solaris
Operating Host Storage External
No. Host System System Bus Host Bus Adapter Topology Array Boot
7 Sun Sun Fire: 280R, 2900, 4800, 4810, 4900, Sun PCI QLogic QLA2340−E−SP1, 3, 5, 6, 13, 28, 30, 31, 32, 33, 35, 49 ; FC−AL, EMC N
6800, 6900, V100, V120, V1280, V210, V240, Solaris 9 Sun: SG−XPCI1FC−EM2 (LP10000)1, 3, 5, 12, 13, 24, 25, 26, 27, 28 , FC−SW CLARiiON
V250, V480, V490, V880, V890 SG−XPCI1FC−QL2 (QLA2340)1, 2, 3, 4, 5, 6 , X6767A AX150
(SG−XPCI1FC−QF2)1, 3, 4, 5, 6, 12, 27, 48
8 Sun Sun Fire V440 Sun PCI QLogic QLA2340−E−SP1, 3, 5, 6, 13, 28, 30, 31, 32, 33, 35, 49 FC−AL, EMC N
Solaris 97 FC−SW CLARiiON
AX150
9 Sun Sun Blade: 1000, 1500, 2000, 2500; Sun PCI Sun: SG−XPCI1FC−EM2 (LP10000)1, 3, 5, 12, 13, 24, 25, 26, 27, 28 , FC−AL, EMC N
Solaris 97 SG−XPCI1FC−QL2 (QLA2340)1, 2, 3, 4, 5, 6 , X6767A FC−SW CLARiiON
Sun Sun Fire: V210, V440; (SG−XPCI1FC−QF2)1, 3, 4, 5, 6, 12, 27, 48 AX150
Sun Ultra: 220R8, 250, 420R8, 450
1. Driver Version SAN 4.4.10
2. FCode Value 1.14.09
3. Driver Version SAN 4.4.9
4. SNIA HBA API Supported.
5. Driver Version SAN 4.4.11
6. FCode Value 1.14.15
7. EMC required Sun patches for Solaris 9:
112233−12 SunOS 5.9: kernel patch
117171−17 SunOS 5.9: kernel patch
118558−34 SunOS 5.9: kernel patch
112834−06 SunOS 5.9: patch SCSI
113277−47 SunOS 5.9: sd and ssd patch
8. 64−bit HBAs will not fit into the 32−bit slot due to a physical obstruction.
9. STMS (MPxIO) is supported with the following patch installed: 119715−09
10. If setting the boot disk from SAN with Solaris 10, its Target/LUN must be defined in the /kernel/drv/sd.conf file.
11. EMC requres Sun patches for Solaris 10:
118822−30 SunOS 5.10: Kernel patch
118833−24 SunOS 5.10: Kernel patch
119130−26 SunOS 5.10: Sun Fibre Channel Device Drivers (only necessary for Leadville Stack driver)
120222−11 SunOS 5.10: Emulex−Sun LightPulse fibre channel adapter driver (only requred for Emulex HBAs)
12. STMS is Sun's Multipathing Software and not an EMC Software product. Please refer to the required release note "SUN
StorEdge Traffic Manager for CLARiiON Release Notes", P/N 300−002−978, which can be found on EMC's Powerlink website in
Support −> Document Library −> Host Connectivity for the complete Installation information.
13. Must add "set ssd:ssd_max_throttle=20" in /etc/system for CLARiiON or Symmetrix attach.
Must add "forceload: drv/ssd" in the /etc/system when these HBA's are installed for Clariion or Symmetrix attach with PowerPath.
(do not include the quotes on either entry)
Driver version SAN 4.3 or older is not supported for MPxIO on EMC Symmetrix storage. MPxIO is not supported on EMC
CLARiiON storage with Solaris 8.
14. Driver Version 4.4.4
15. Driver Version SAN 4.4.2
16. Driver Version SAN 4.4.8
17. Driver Version SAN 4.4.7a
18. Driver Version SAN 4.4.6
19. Driver Version SAN 4.4.4
20. Driver Version SAN 4.4.3
21. Driver Version SAN 4.4.1
22. Driver Version 4.4.3
23. For Solaris 10 versions prior to S10−U1, there are 2 packages SUNWemlxs and SUNWemlxu that are required before installing
required patch 120222−04. These packages are available on the Sun website:
http://www.sun.com/download/products.xml?id=42c4317d
24. FCode Value 1.50a9
25. FCode Value 1.50a4
26. FCode Value 1.50a8
27. Sun StorEdge Traffic Manager Software (Sun's Native Multipathing Software) is supported on CLARiiON with SAN 4.4.7a and
above.
28. For servers running Solaris 8 or 9 with the Sun SAN driver, the following applies:
Must add "set fcp:ssfcp_enable_auto_configuration=1" (do not include quote marks) in /etc/system to fix the following problems:
1. VxVM − rootdg can not be imported during boot
2. SVM − Volume Manager can not be started after system boot
3. PowerPath 4.x − error message "All paths to (array type) (array name) vol(volume number) are dead"
29. SDS support on Solaris 8 requires minimum SDS version 4.2.1 with patch 108693−16 or later version.
30. Driver Version 4.17
31. FCode Value 2.00.09
32. Driver Version 4.22
33. FCode Value 1.14.13
34. Driver Version S10 Update 1 (01/06)
35. FCode Value 2.00.06
36. Driver Version 6.02f
37. Firmware Version 1.91a1
38. Driver Version SAN in Solaris 10 U1 (01/06)
39. Driver Version 6.02hx2
40. Firmware Version 1.91a5
41. Driver Version 6.10g
42. Firmware Version 3.92a3
43. Firmware Version 3.93a0
44. The LP8000−EMC HBA has a permanent GBIC, and does not have copper cable support.
45. Firmware Version 3.92a2
46. FCode Value 1.41a4
47. Driver Version 6.02e
48. FCode Value 1.14.11
49. Driver Version 4.15.03

VMware ESX Server

11/02/2006 360 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
1 HPQ Proliant DL380(G3)21 VMware ESX Server v3.0.12, 3, 6, PCI Emulex: LP1050−E10, 18, 29, LP982−E29, 37, 38; FC−AL, EMC Y9, 16
8, 30 FC−SW CLARiiON
QLogic QLA2340−E−SP33, 39 AX150
2 Fujitsu Siemens Primergy BX66057 VMware ESX Server v3.0.12, 3, 6, PCI Fujitsu Siemens BX600−FC22Q12, 24, 33, 58 FC−AL, EMC Y9, 16
8, 30 FC−SW CLARiiON
AX150
3 Dell PowerEdge: 1950, 6850; VMware ESX Server v3.0.12, 3, 6, PCI Emulex LP1050Ex−E10, 11, 12, 29 FC−AL, EMC Y9, 16
8, 30 Express FC−SW CLARiiON
Fujitsu Siemens Primergy RX300 S3 AX150
4 Fujitsu Siemens Primergy RX300 S3 VMware ESX Server v3.0.12, 3, 6, PCI Emulex LP1050Ex−E10, 12, 29, 37 ; FC−AL, EMC Y9, 16
8, 30 Express QLogic QLA2340−E−SP33 FC−SW CLARiiON
AX150
5 Dell PowerEdge 1950 VMware ESX Server v3.0.12, 3, 6, PCI Emulex: LP1050−E10, 18, 29, LP982−E29, 37, 38; FC−AL, EMC Y9, 16
8, 30 Express FC−SW CLARiiON
QLogic QLE2360−E−SP12, 33, 36 AX150
6 Dell PowerEdge 1950; VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLA2340−E−SP33, 39 FC−AL, EMC Y9, 16
Fujitsu Siemens Primergy RX300 S3 8, 30 Express FC−SW CLARiiON
AX150
7 Dell PowerEdge 6850 VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLE2360−E−SP12, 33 FC−AL, EMC Y9, 16
8, 30 Express FC−SW CLARiiON
AX150
8 Dell PowerEdge 6850 VMware ESX Server v3.0.12, 3, 6, PCI Dell 2362M33, 48, 49 FC−AL, EMC Y9, 16
8, 30 Express, FC−SW CLARiiON
PCI−X AX150
9 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.12, 3, 6, PCI Emulex LP1050−E10, 18, 29 FC−AL, EMC Y9, 16
2950, 6850, 6950; 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
IBM xSeries: x336 (8837)43, x3550
(7978), x3650 (7979), x3755 (8877)
10 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.12, 3, 6, PCI Emulex LP1050Ex−E10, 11, 12, 29 FC−AL, EMC Y9, 16
2950, 6850, 6950; 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
Fujitsu Siemens Primergy TX300 S3;
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)43, xSeries x3755
(8877)
11 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server v3.0.12, 3, 6, PCI Emulex LP1050Ex−E10, 12, 29, 37 FC−AL, EMC Y9, 16
IBM: eServer 326m (Model 7969), 8, 30 Express, FC−SW CLARiiON
xSeries x3755 (8877) PCI−X AX150
12 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.12, 3, 6, PCI Emulex LP982−E29, 37, 38 FC−AL, EMC Y9, 16
2950, 6850, 6950; 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
IBM xSeries: x336 (8837)43, x3550
(7978), x3650 (7979)
13 Dell PowerEdge: 2900, 2950, 6950; VMware ESX Server v3.0.12, 3, 6, PCI Emulex LPe1150−E10, 12, 28, 29 FC−AL, EMC Y9, 16
8, 30 Express, FC−SW CLARiiON
Fujitsu Siemens Primergy RX600 S3 PCI−X AX150
14 IBM xSeries x3755 (8877) VMware ESX Server v3.0.12, 3, 6, PCI Emulex: LP1050−E10, 12, 29, 37 , LP1050−E10, 29, 37 FC−AL, EMC Y9, 16
8, 30 Express, FC−SW CLARiiON
PCI−X AX150
15 IBM xSeries: x3550 (7978), x3650 VMware ESX Server v3.0.12, 3, 6, PCI IBM 24P0960 (QLA2340)24, 33, 42 FC−AL, EMC Y9, 16
(7979), x3755 (8877) 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
16 NEC Express 5800 120Ri−2 VMware ESX Server v3.0.12, 3, 6, PCI NEC N8190−120 (LP1050)10, 11, 17, 29 FC−AL, EMC Y9, 16
8, 30 Express, FC−SW CLARiiON
PCI−X AX150
17 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLA2340−E−SP33 FC−AL, EMC Y9, 16
IBM xSeries x3755 (8877) 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
18 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLA2340−E−SP33, 39 FC−AL, EMC Y9, 16
2950, 6850, 6950; 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
Fujitsu Siemens Primergy TX300 S3;
IBM xSeries: x336 (8837)43, x346
(8840)43, x3550 (7978), x3650
(7979), x3755 (8877)
19 IBM: eServer 326m (Model 7969), VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLE2360−E−SP12, 33 FC−AL, EMC Y9, 16
xSeries x3755 (8877) 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
20 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLE2360−E−SP12, 33, 36 FC−AL, EMC Y9, 16
2950, 6950; 8, 30 Express, FC−SW CLARiiON
PCI−X AX150
IBM: eServer 326m (Model 7969),
xSeries x3755 (8877)
21 Dell PowerEdge: 2900, 2950, 6950; VMware ESX Server v3.0.12, 3, 6, PCI QLogic QLE2460−E−SP12, 32, 33 FC−AL, EMC Y
8, 30 Express, FC−SW CLARiiON
IBM: eServer 326m (Model 7969), PCI−X AX150
xSeries x3755 (8877)
22 Dell PowerEdge 1855 VMware ESX Server v3.0.12, 3, 6, PCI−X Dell 2342M24, 33 FC−AL, EMC Y9, 16
8, 30 FC−SW CLARiiON
AX150
23 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server v3.0.12, 3, 6, PCI−X Emulex LP1050−E10, 12, 29, 37 FC−AL, EMC Y9, 16
8, 30 FC−SW CLARiiON
AX150
24 HPQ Proliant DL360(G4)21 VMware ESX Server v3.0.12, 3, 6, PCI−X Emulex LP1050Ex−E10, 11, 12, 29 FC−AL, EMC Y9, 16
8, 30 FC−SW CLARiiON
AX150

11/02/2006 361 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
25 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server v3.0.12, 3, 6, PCI−X Emulex LP1050Ex−E10, 12, 29, 37 FC−AL, EMC Y9, 16
TX600 S2 8, 30 FC−SW CLARiiON
AX150
26 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server v3.0.12, 3, 6, PCI−X Emulex: LP1050−E10, 18, 29, LP982−E29, 37, 38 FC−AL, EMC Y9, 16
6650; 8, 30 FC−SW CLARiiON
AX150
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL74021, DL760
(G2)21, ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)25;
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun: V40z, x4100, x4200
27 HPQ Proliant BL45p VMware ESX Server v3.0.12, 3, 6, PCI−X HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y9, 16
8, 30 Proliant BL25p/BL45p 381881−B2133, 50, FC−SW CLARiiON
Emulex−based BL25/30/35/45p Fibre Channel AX150
Mezzanine HBA − 394588−B2129
28 IBM xSeries: x235, x365, x3850/x366 VMware ESX Server v3.0.12, 3, 6, PCI−X IBM 24P0960 (QLA2340)24, 33, 42 FC−AL, EMC Y9, 16
(8863)25 8, 30 FC−SW CLARiiON
AX150
29 NEC Express 5800: 120Rh−2, VMware ESX Server v3.0.12, 3, 6, PCI−X NEC N8190−120 (LP1050)10, 11, 17, 29 FC−AL, EMC Y9, 16
140Rd−4 8, 30 FC−SW CLARiiON
AX150
30 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server v3.0.12, 3, 6, PCI−X QLogic QLA2340−E−SP33 FC−AL, EMC Y9, 16
TX600 S2; 8, 30 FC−SW CLARiiON
AX150
Sun: V40z, x4100, x4200
31 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server v3.0.12, 3, 6, PCI−X QLogic QLA2340−E−SP33, 39 FC−AL, EMC Y9, 16
6650; 8, 30 FC−SW CLARiiON
AX150
Fujitsu Siemens Primergy: RX600 S2,
TX600 S2;
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL74021, DL760
(G2)21, ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)25;
Sun: V40z, x4100, x4200
32 HPQ Proliant BL20p (G2) VMware ESX Server v3.0.12, 3, 6, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y9, 16
8, 30 BL20p (G2) 300874−B2119, 33 FC−SW CLARiiON
AX150
33 HPQ Proliant BL25p VMware ESX Server v3.0.12, 3, 6, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y9, 16
8, 30 BL25p/BL45p 381881−B2133, 50 FC−SW CLARiiON
AX150
34 HPQ Proliant: BL25p, BL35p VMware ESX Server v3.0.12, 3, 6, PCI−X14 HPQ Emulex−based BL25/30/35/45p Fibre Channel FC−AL, EMC Y9, 16
8, 30 Mezzanine HBA − 394588−B2129 FC−SW CLARiiON
AX150
35 HPQ Proliant BL20p (G3) VMware ESX Server v3.0.12, 3, 6, PCI−X14 HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y9, 16
8, 30 Proliant BL20p (G3) 361426−B2119, 33, FC−SW CLARiiON
Emulex−based BL20p (G3) Fibre Channel Mezzanine AX150
HBA − 394757−B2129
36 IBM xSeries: x3800/x260 (8865)25, VMware ESX Server v3.0.12, 3, 6, PCI−X26 Emulex: LP1050−E10, 18, 29, LP982−E29, 37, 38; FC−AL, EMC Y9, 16
x3950/x3950E/x460 (8872, 8874)25 8, 30 FC−SW CLARiiON
IBM 24P0960 (QLA2340)24, 33, 42; AX150
QLogic QLA2340−E−SP33, 39
37 Dell PowerEdge 1955 VMware ESX Server v3.0.12, 3, 6, PCI, PCI Dell 2342M24, 33 FC−AL, EMC Y9, 16
8, 30 Express, FC−SW CLARiiON
PCI−X AX150
38 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v3.0.12, 3, 6, PCI, PCI Emulex: LP1050−E10, 18, 29, LP1050Ex−E10, 11, 12, FC−AL, EMC Y9, 16
8, 30 Express, 29, LP982−E29, 37, 38; FC−SW CLARiiON
PCI−X AX150
QLogic QLA2340−E−SP33, 39
39 HPQ Proliant: DL380(G4)21, VMware ESX Server v3.0.12, 3, 6, PCI, Emulex LP1050Ex−E10, 11, 12, 29 FC−AL, EMC Y9, 16
DL580(G3)21 8, 30 PCI−X FC−SW CLARiiON
AX150
40 Fujitsu Siemens Primergy: RX600, VMware ESX Server v3.0.12, 3, 6, PCI, Emulex: LP1050−E10, 12, 29, 37 , LP1050−E10, 29, 37; FC−AL, EMC Y9, 16
TX600 8, 30 PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP33 AX150
41 HPQ Proliant: DL380(G4)21, VMware ESX Server v3.0.12, 3, 6, PCI, Emulex: LP1050−E10, 18, 29, LP982−E29, 37, 38 FC−AL, EMC Y9, 16
DL38521, DL580(G2)21, 8, 30 PCI−X FC−SW CLARiiON
DL580(G3)21, DL58521, AX150
ML370(G3)21, ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
42 IBM: eServer 325 (Model 8835), VMware ESX Server v3.0.12, 3, 6, PCI, IBM 24P0960 (QLA2340)24, 33, 42 FC−AL, EMC Y9, 16
xSeries x445 (8870) 8, 30 PCI−X FC−SW CLARiiON
AX150
43 Fujitsu Siemens Primergy: RX600, VMware ESX Server v3.0.12, 3, 6, PCI, QLogic QLA2340−E−SP33, 39 FC−AL, EMC Y9, 16
TX600; 8, 30 PCI−X FC−SW CLARiiON
AX150
HPQ Proliant: DL380(G4)21,
DL38521, DL580(G2)21,
DL580(G3)21, DL58521,
ML370(G3)21, ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)

11/02/2006 362 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
44 HPQ Proliant: DL380(G3)21, VMware ESX Server: v3.0.12, 3, 6, PCI HPQ AD167A/FC2143 (LP1150)10, 12, 29, 45 FC−AL, EMC Y9, 16
DL580(G2)21 8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, FC−SW CLARiiON
8, 30, 31 AX150
45 Dell PowerEdge: 1850, 1950, 2800, VMware ESX Server: v3.0.12, 3, 6, PCI Emulex LPe1150−E10, 12, 28, 29 FC−AL, EMC Y9, 16
2850, 6800, 6850; 8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, Express FC−SW CLARiiON
8, 30, 31 AX150
HPQ Proliant: DL360(G4)21,
DL380(G4)21, DL580(G3)21,
ML370(G4)21
46 HPQ Proliant: DL360(G4)21, VMware ESX Server: v3.0.12, 3, 6, PCI HPQ: A8002A/FC2142SR (LPe1150)10, 12, 29, 41 , FC−AL, EMC Y9, 16
DL380(G4)21, DL580(G3)21, 8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, Express AD167A/FC2143 (LP1150)10, 12, 29, 45 FC−SW CLARiiON
ML370(G4)21 8, 30, 31 AX150
47 HPQ Proliant DL360(G4)21 VMware ESX Server: v3.0.12, 3, 6, PCI HPQ AD167A/FC2143 (LP1150)10, 12, 29, 45 FC−AL, EMC Y9, 16
8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, Express, FC−SW CLARiiON
8, 30, 31 PCI−X AX150
48 NEC Express 5800: 120Ri−2, VMware ESX Server: v3.0.12, 3, 6, PCI NEC N8190−127 (LPe1150)17, 29, 40, 41 FC−AL, EMC Y9, 16
140Rd−4 8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, Express, FC−SW CLARiiON
8, 30, 31 PCI−X AX150
49 Dell PowerEdge 1855 VMware ESX Server: v3.0.12, 3, 6, PCI−X Dell LPe1105−M10, 12, 28, 29 FC−AL, EMC Y9, 16
8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, FC−SW CLARiiON
8, 30, 31 AX150
50 HPQ Proliant: BL40p, DL360(G3)21, VMware ESX Server: v3.0.12, 3, 6, PCI−X HPQ AD167A/FC2143 (LP1150)10, 12, 29, 45 FC−AL, EMC Y9, 16
DL360(G4)21, DL74021, DL760 8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, FC−SW CLARiiON
(G2)21, ML570(G2)21 8, 30, 31 AX150
51 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server: v3.0.12, 3, 6, PCI, PCI Emulex LPe1150−E10, 12, 28, 29 ; FC−AL, EMC Y9, 16
8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, Express, HPQ: A8002A/FC2142SR (LPe1150)10, 12, 29, 41 , FC−SW CLARiiON
8, 30, 31 PCI−X AD167A/FC2143 (LP1150)10, 12, 29, 45 AX150
52 HPQ Proliant: DL380(G3)21, VMware ESX Server: v3.0.12, 3, 6, PCI, HPQ AD167A/FC2143 (LP1150)10, 12, 29, 45 FC−AL, EMC Y9, 16
DL380(G4)21, DL38521, 8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, PCI−X FC−SW CLARiiON
DL580(G2)21, DL580(G3)21, 8, 30, 31 AX150
ML370(G3)21, ML370(G4)21
53 Dell PowerEdge 1955 VMware ESX Server: v3.0.12, 3, 6, PCI, PCI Dell LPe1105−M10, 12, 29 FC−AL, EMC Y9, 16
8, 30, v3.02, 3, 6, 30, 31 , v3.02, 3, 6, Express, FC−SW CLARiiON
8, 30, 31, v3.03, 6, 30, 31 , v3.03, 6, 8, PCI−X AX150
30, 31

54 Dell PowerEdge: 1850, 1950, 2800, VMware ESX Server: v3.0.12, 3, 6, PCI QLogic QLE2460−E−SP12, 32, 33 FC−AL, EMC Y
2850, 6800, 6850 8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, Express FC−SW CLARiiON
31 AX150
55 HPQ Proliant DL360(G4)21 VMware ESX Server: v3.0.12, 3, 6, PCI−X HPQ AB429A/FC1143 (QLA2460)12, 33, 46 FC−AL, EMC Y9, 16
8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, FC−SW CLARiiON
31 AX150
56 HPQ Proliant DL380(G5) VMware ESX Server: v3.0.12, 3, 6, PCI, PCI HPQ AB429A/FC1143 (QLA2460)12, 33, 46 FC−AL, EMC Y9, 16
8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, Express, FC−SW CLARiiON
31 PCI−X AX150
57 HPQ Proliant: DL380(G4)21, VMware ESX Server: v3.0.12, 3, 6, PCI, HPQ AB429A/FC1143 (QLA2460)12, 33, 46 FC−AL, EMC Y9, 16
DL38521, DL58521, ML370(G4)21 8, 30, v3.03, 6, 30, 31 , v3.03, 6, 8, 30, PCI−X FC−SW CLARiiON
31 AX150
58 Dell PowerEdge: 2900, 2950; VMware ESX Server: v3.02, 3, 6, PCI Emulex LPe1150−E10, 12, 28, 29 FC−AL, EMC Y9, 16
30, 31, v3.02, 3, 6, 8, 30, 31 Express, FC−SW CLARiiON
Fujitsu Siemens Primergy RX600 S3 PCI−X AX150
59 Dell PowerEdge 1955 VMware ESX Server: v3.02, 3, 6, PCI, PCI Dell 2342M20, 24 FC−AL, EMC Y9, 16
30, 31, v3.02, 3, 6, 8, 30, 31 , v3.03, 6, Express, FC−SW CLARiiON
30, 31, v3.03, 6, 8, 30, 31 PCI−X AX150
60 HPQ Proliant DL380(G3)21 VMware ESX Server: v3.03, 6, 30, PCI Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38; FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
QLogic QLA2340−E−SP20, 39 AX150
61 Fujitsu Siemens Primergy BX66057 VMware ESX Server: v3.03, 6, 30, PCI Fujitsu Siemens BX600−FC22Q12, 20, 24, 58 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
62 Dell PowerEdge: 1950, 6850; VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 11, 12, 34 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
Fujitsu Siemens Primergy RX300 S3 AX150
63 Fujitsu Siemens Primergy RX300 S3 VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 12, 34, 37 ; FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express QLogic QLA2340−E−SP20 FC−SW CLARiiON
AX150
64 Dell PowerEdge 1950 VMware ESX Server: v3.03, 6, 30, PCI Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38; FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
QLogic QLE2360−E−SP12, 20, 36 AX150
65 Dell PowerEdge 1950; VMware ESX Server: v3.03, 6, 30, PCI QLogic QLA2340−E−SP20, 39 FC−AL, EMC Y9, 16
Fujitsu Siemens Primergy RX300 S3 31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
AX150
66 Dell PowerEdge 6850 VMware ESX Server: v3.03, 6, 30, PCI QLogic QLE2360−E−SP12, 20 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express FC−SW CLARiiON
AX150
67 Dell PowerEdge 6850 VMware ESX Server: v3.03, 6, 30, PCI Dell 2362M20, 48, 49 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
68 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 11, 12, 34 FC−AL, EMC Y9, 16
2950, 6850; 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
Fujitsu Siemens Primergy TX300 S3;
IBM: eServer 326m (Model 7969),
xSeries x336 (8837)43
69 Fujitsu Siemens Primergy TX300 S3; VMware ESX Server: v3.03, 6, 30, PCI Emulex LP1050Ex−E10, 12, 34, 37 FC−AL, EMC Y9, 16
IBM eServer 326m (Model 7969) 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150

11/02/2006 363 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
70 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.03, 6, 30, PCI Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38 FC−AL, EMC Y9, 16
2950, 6850; 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
IBM xSeries: x336 (8837)43, x3550
(7978), x3650 (7979)
71 IBM xSeries: x3550 (7978), x3650 VMware ESX Server: v3.03, 6, 30, PCI IBM 24P0960 (QLA2340)20, 24, 42 FC−AL, EMC Y9, 16
(7979) 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
72 NEC Express 5800 120Ri−2 VMware ESX Server: v3.03, 6, 30, PCI NEC N8190−120 (LP1050)10, 11, 17, 34 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
73 Fujitsu Siemens Primergy TX300 S3 VMware ESX Server: v3.03, 6, 30, PCI QLogic QLA2340−E−SP20 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
74 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.03, 6, 30, PCI QLogic QLA2340−E−SP20, 39 FC−AL, EMC Y9, 16
2950, 6850; 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
Fujitsu Siemens Primergy TX300 S3;
IBM xSeries: x336 (8837)43, x346
(8840)43, x3550 (7978), x3650 (7979)
75 IBM eServer 326m (Model 7969) VMware ESX Server: v3.03, 6, 30, PCI QLogic QLE2360−E−SP12, 20 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
76 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server: v3.03, 6, 30, PCI QLogic QLE2360−E−SP12, 20, 36 FC−AL, EMC Y9, 16
2950; 31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
PCI−X AX150
IBM eServer 326m (Model 7969)
77 Dell PowerEdge: 2900, 2950; VMware ESX Server: v3.03, 6, 30, PCI QLogic QLE2460−E−SP12, 32, 33 FC−AL, EMC Y
31, v3.03, 6, 8, 30, 31 Express, FC−SW CLARiiON
IBM eServer 326m (Model 7969) PCI−X AX150
78 Dell PowerEdge 1855 VMware ESX Server: v3.03, 6, 30, PCI−X Dell 2342M20, 24 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
79 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server: v3.03, 6, 30, PCI−X Emulex LP1050−E10, 12, 34, 37 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
80 HPQ Proliant DL360(G4)21 VMware ESX Server: v3.03, 6, 30, PCI−X Emulex LP1050Ex−E10, 11, 12, 34 FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
81 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server: v3.03, 6, 30, PCI−X Emulex LP1050Ex−E10, 12, 34, 37 FC−AL, EMC Y9, 16
TX600 S2 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
82 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server: v3.03, 6, 30, PCI−X Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38 FC−AL, EMC Y9, 16
6650; 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL74021, DL760
(G2)21, ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)25;
NEC Express 5800: 120Rh−2,
140Rd−4;
Sun: V40z, x4100, x4200
83 HPQ Proliant BL45p VMware ESX Server: v3.03, 6, 30, PCI−X HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Proliant BL25p/BL45p 381881−B2120, 50, FC−SW CLARiiON
Emulex−based BL25/30/35/45p Fibre Channel AX150
Mezzanine HBA − 394588−B2134
84 IBM xSeries: x235, x365, x3850/x366 VMware ESX Server: v3.03, 6, 30, PCI−X IBM 24P0960 (QLA2340)20, 24, 42 FC−AL, EMC Y9, 16
(8863)25 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
85 NEC Express 5800: 120Rh−2, VMware ESX Server: v3.03, 6, 30, PCI−X NEC N8190−120 (LP1050)10, 11, 17, 34 FC−AL, EMC Y9, 16
140Rd−4 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
86 Fujitsu Siemens Primergy: RX600 S2, VMware ESX Server: v3.03, 6, 30, PCI−X QLogic QLA2340−E−SP20 FC−AL, EMC Y9, 16
TX600 S2; 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
Sun: V40z, x4100, x4200
87 Dell PowerEdge: 1750, 2600, 2650, VMware ESX Server: v3.03, 6, 30, PCI−X QLogic QLA2340−E−SP20, 39 FC−AL, EMC Y9, 16
6650; 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
AX150
Fujitsu Siemens Primergy: RX600 S2,
TX600 S2;
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL74021, DL760
(G2)21, ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x365, xSeries
x3850/x366 (8863)25;
Sun: V40z, x4100, x4200
88 HPQ Proliant BL20p (G2) VMware ESX Server: v3.03, 6, 30, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 BL20p (G2) 300874−B2119, 20 FC−SW CLARiiON
AX150

11/02/2006 364 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
89 HPQ Proliant BL25p VMware ESX Server: v3.03, 6, 30, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 BL25p/BL45p 381881−B2120, 50 FC−SW CLARiiON
AX150
90 HPQ Proliant: BL25p, BL35p VMware ESX Server: v3.03, 6, 30, PCI−X14 HPQ Emulex−based BL25/30/35/45p Fibre Channel FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Mezzanine HBA − 394588−B2134 FC−SW CLARiiON
AX150
91 HPQ Proliant BL20p (G3) VMware ESX Server: v3.03, 6, 30, PCI−X14 HPQ: Dual−port Fibre Channel Adapter for HP FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Proliant BL20p (G3) 361426−B2119, 20, FC−SW CLARiiON
Emulex−based BL20p (G3) Fibre Channel Mezzanine AX150
HBA − 394757−B2134
92 IBM xSeries: x3800/x260 (8865)25, VMware ESX Server: v3.03, 6, 30, PCI−X26 Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38; FC−AL, EMC Y9, 16
x3950/x3950E/x460 (8872, 8874)25 31, v3.03, 6, 8, 30, 31 FC−SW CLARiiON
IBM 24P0960 (QLA2340)20, 24, 42; AX150
QLogic QLA2340−E−SP20, 39
93 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server: v3.03, 6, 30, PCI, PCI Emulex: LP1050−E10, 18, 34, LP1050Ex−E10, 11, 12, FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 Express, 34, LP982−E34, 37, 38; FC−SW CLARiiON
PCI−X AX150
QLogic QLA2340−E−SP20, 39
94 HPQ Proliant: DL380(G4)21, VMware ESX Server: v3.03, 6, 30, PCI, Emulex LP1050Ex−E10, 11, 12, 34 FC−AL, EMC Y9, 16
DL580(G3)21 31, v3.03, 6, 8, 30, 31 PCI−X FC−SW CLARiiON
AX150
95 Fujitsu Siemens Primergy: RX600, VMware ESX Server: v3.03, 6, 30, PCI, Emulex: LP1050−E10, 12, 34, 37 , LP1050−E10, 34, 37; FC−AL, EMC Y9, 16
TX600 31, v3.03, 6, 8, 30, 31 PCI−X FC−SW CLARiiON
QLogic QLA2340−E−SP20 AX150
96 HPQ Proliant: DL380(G4)21, VMware ESX Server: v3.03, 6, 30, PCI, Emulex: LP1050−E10, 18, 34, LP982−E34, 37, 38 FC−AL, EMC Y9, 16
DL38521, DL580(G2)21, 31, v3.03, 6, 8, 30, 31 PCI−X FC−SW CLARiiON
DL580(G3)21, DL58521, AX150
ML370(G3)21, ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
97 IBM: eServer 325 (Model 8835), VMware ESX Server: v3.03, 6, 30, PCI, IBM 24P0960 (QLA2340)20, 24, 42 FC−AL, EMC Y9, 16
xSeries x445 (8870) 31, v3.03, 6, 8, 30, 31 PCI−X FC−SW CLARiiON
AX150
98 Fujitsu Siemens Primergy: RX600, VMware ESX Server: v3.03, 6, 30, PCI, QLogic QLA2340−E−SP20, 39 FC−AL, EMC Y9, 16
TX600; 31, v3.03, 6, 8, 30, 31 PCI−X FC−SW CLARiiON
AX150
HPQ Proliant: DL380(G4)21,
DL38521, DL580(G2)21,
DL580(G3)21, DL58521,
ML370(G3)21, ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x445 (8870)
99 HPQ Proliant BL35p VMware ESX Server v3.0.12, 3, 6, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y9, 16
8, 30 BL30p/BL35p 354054−B2119, 33 FC−SW51 CLARiiON
AX150
100 HPQ Proliant BL35p VMware ESX Server: v3.03, 6, 30, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−AL, EMC Y9, 16
31, v3.03, 6, 8, 30, 31 BL30p/BL35p 354054−B2119, 20 FC−SW51 CLARiiON
AX150
101 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server v2.5.22, 3, 5, PCI−X QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
2650, 4600, 6600, 6650; 6, 7 CLARiiON
AX150
Fujitsu Siemens Primergy: RX300,
RX300 S2, RX600 S2, TX300, TX300
S2, TX600 S2;
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL56021, DL74021,
DL760 (G2)21, DL76021,
ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)25, xSeries x440;
NEC Express 5800 120Lh;
Sun: V20z, V40z
102 Fujitsu Siemens Primergy: RX600, VMware ESX Server v2.5.22, 3, 5, PCI, QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
RX800, RX800 S2, TX600; 6, 7 PCI−X CLARiiON
AX150
HPQ Proliant: DL380(G2)21,
DL380(G4)21, DL38021, DL38521,
DL580(G2)21, DL580(G3)21,
DL58521, ML370(G3)21,
ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
103 Dell PowerEdge 6850 VMware ESX Server v2.5.32, 3, 5, PCI Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
6, 7 Express CLARiiON
AX150
104 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server v2.5.32, 3, 5, PCI Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
6, 7 Express, CLARiiON
IBM xSeries x336 (8837)43 PCI−X AX150
105 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server v2.5.32, 3, 5, PCI Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
6, 7 Express, CLARiiON
IBM xSeries x336 (8837)43; PCI−X AX150
NEC Express 5800 110Rg−1

11/02/2006 365 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
106 HPQ Proliant BL20p (G3) VMware ESX Server v2.5.32, 3, 5, PCI−X14 HPQ Emulex−based BL20p (G3) Fibre Channel FC−SW EMC Y9, 16
6, 7 Mezzanine HBA − 394757−B2113, 15 CLARiiON
AX150
107 Dell PowerEdge: 1950, 6850 VMware ESX Server v2.5.41, 2, 3, PCI Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
4, 5, 6, 7, 8 Express CLARiiON
AX150
108 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, 3, PCI Emulex: LP1050−E10, 12, 13, 37 , LP1050−E10, 13, 18, FC−SW EMC N9
4, 5, 6, 7, 8 Express LP982−E10, 13 CLARiiON
AX150
109 Dell PowerEdge: 1950, 6850 VMware ESX Server v2.5.41, 2, 3, PCI QLogic QLE2360−E−SP12, 20, 44 FC−SW EMC Y9, 16
4, 5, 6, 7, 8 Express CLARiiON
AX150
110 Dell PowerEdge 1950 VMware ESX Server v2.5.41, 2, 3, PCI QLogic: QLA2340−E−SP20, 24, QLE2360−E−SP12, 20, FC−SW EMC Y9, 16
4, 5, 6, 7, 8 Express 36, 44 CLARiiON
AX150
111 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, 3, PCI Emulex LP1050−E10, 12, 13, 37 FC−SW EMC N9
4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
112 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, 3, PCI Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
2950, 6850; 4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
IBM xSeries x336 (8837)43
113 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, 3, PCI Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
2950, 6850; 4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
IBM xSeries x336 (8837)43;
NEC Express 5800 110Rg−1
114 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, 3, PCI QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
2950, 6850; 4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
IBM xSeries: x336 (8837)43, x346
(8840)43
115 Dell PowerEdge: 1850, 2850, 2900, VMware ESX Server v2.5.41, 2, 3, PCI QLogic QLE2360−E−SP12, 20, 36, 44 FC−SW EMC Y9, 16
2950 4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
116 Dell PowerEdge: 2900, 2950 VMware ESX Server v2.5.41, 2, 3, PCI QLogic QLE2360−E−SP12, 20, 44 FC−SW EMC Y9, 16
4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
117 HPQ Proliant BL20p: (G3), (G4) VMware ESX Server v2.5.41, 2, 3, PCI−X14 HPQ: Dual−port Fibre Channel Adapter for HP FC−SW EMC Y9, 16
4, 5, 6, 7, 8 Proliant BL20p (G3) 361426−B2119, 20, CLARiiON
Emulex−based BL20p (G3) Fibre Channel Mezzanine AX150
HBA − 394757−B2113, 15
118 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v2.5.41, 2, 3, PCI, PCI Emulex: LP1050−E10, 13, 18, LP1050Ex−E10, 11, 12, FC−SW EMC N9
4, 5, 6, 7, 8 Express, 13, LP982−E10, 13 CLARiiON
PCI−X AX150
119 HPQ Proliant: DL380(G5), DL580(G4) VMware ESX Server v2.5.41, 2, 3, PCI, PCI QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
120 HPQ Proliant BL460c: (416653−B21), VMware ESX Server v3.0.12, 3, 6, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−SW EMC N
(416654−B21), (416655−B21), 8, 30 Bladesystem (403619−B21)53, 56 CLARiiON
(416656−B21), (432636−B21); AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
121 IBM BladeCenter HS20 (Model: VMware ESX Server v3.0.12, 3, 6, PCI−X IBM Emulex LP1005DC FC Exp Card12, 29 FC−SW EMC Y9, 16
8832)35, 8832−N1X), 8843); 8, 30 CLARiiON
AX150
IBM BladeCenter: HS40 (Model
8839), LS20 (Model 8850)
122 IBM BladeCenter HS20 (Model: VMware ESX Server v3.0.12, 3, 6, PCI−X IBM HS20 FC Exp Card (13N2203)24, 33 FC−SW EMC Y9, 16
8832)35, 8832−N1X); 8, 30 CLARiiON
AX150
IBM BladeCenter HS40 (Model 8839)
123 IBM BladeCenter HS20 (Model 8843) VMware ESX Server v3.0.12, 3, 6, PCI−X IBM HS20 FC Exp Card (26K4841)12, 24, 33, 47 FC−SW EMC Y9, 16
8, 30 CLARiiON
AX150
124 IBM BladeCenter HS20 (Model: VMware ESX Server v3.0.12, 3, 6, PCI−X IBM HS20 FC Exp Card (48P7061)12, 33 FC−SW EMC Y9, 16
8832)35, 8832−N1X), 8843) 8, 30 CLARiiON
AX150
125 IBM BladeCenter LS20 (Model 8850) VMware ESX Server v3.0.12, 3, 6, PCI−X IBM HS20 FC: Exp Card (13N2203) for IBM eServer FC−SW EMC Y9, 16
8, 30 LS2012, 24, 33, SFF Exp Card (26K4841) for IBM CLARiiON
eServer LS2012, 33 AX150
126 IBM BladeCenter HS21 (Model VMware ESX Server v3.0.12, 3, 6, PCI−X IBM: Emulex 4Gb SFF Fibre Channel Exp Card FC−SW EMC Y9, 16
8853)52 8, 30 (39Y9186)12, 29, HS20 4GB SFF FC Exp Card CLARiiON
(26R0890)12, 53, 55, HS20 FC Exp Card (13N2203)12, AX150
53, 54, HS20 FC Exp Card (48P7061)12, 53

127 HPQ Proliant BL460c: (416653−B21), VMware ESX Server v3.02, 3, 6, 8, PCI−X HPQ QLogic QMH2462 4Gb FC HBA for HP c−Class FC−SW EMC N
(416654−B21), (416655−B21), 30 Bladesystem (403619−B21)33, 56 CLARiiON
(416656−B21), (432636−B21); AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
128 Dell PowerEdge 6850 VMware ESX Server: v2.5.22, 3, 5, PCI QLogic QLE2360−E−SP12, 20, 44 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 Express CLARiiON
AX150

11/02/2006 366 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
129 Dell PowerEdge: 1850, 2850, 6850; VMware ESX Server: v2.5.22, 3, 5, PCI QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 Express, CLARiiON
IBM xSeries: x336 (8837)43, x346 PCI−X AX150
(8840)43
130 Dell PowerEdge: 1850, 2850 VMware ESX Server: v2.5.22, 3, 5, PCI QLogic QLE2360−E−SP12, 20, 36, 44 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 Express, CLARiiON
PCI−X AX150
131 HPQ Proliant BL20p (G3) VMware ESX Server: v2.5.22, 3, 5, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 BL20p (G3) 361426−B2119, 20 CLARiiON
AX150
132 Fujitsu Siemens Primergy BX620: VMware ESX Server: v2.5.22, 3, 5, PCI Fujitsu Siemens BX600−FC22Q12, 20, 24, 58 FC−SW EMC Y9, 16
S2F57, S257; 6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 AX150
Fujitsu Siemens Primergy: BX62057,
BX630 (2−way)63, BX66057
133 Dell PowerEdge: 1550, 255022, 6450; VMware ESX Server: v2.5.22, 3, 5, PCI QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
HPQ Proliant: DL360(G2)21, 4, 5, 6, 7, 8 AX150
21 21
DL360 , DL380(G3) , DL580 ; 21

IBM xSeries: x330, x335;


NEC Express 5800 140Hd
134 Dell PowerEdge 6850 VMware ESX Server: v2.5.22, 3, 5, PCI Dell 2362M20, 48, 49 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, Express, CLARiiON
4, 5, 6, 7, 8 PCI−X AX150
135 Dell PowerEdge 1855 VMware ESX Server: v2.5.22, 3, 5, PCI−X Dell 2342M20, 24 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 AX150
136 HPQ Proliant BL45p VMware ESX Server: v2.5.22, 3, 5, PCI−X HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, BL25p/BL45p 381881−B2120, 50 CLARiiON
4, 5, 6, 7, 8 AX150
137 IBM BladeCenter HS20 (Model: VMware ESX Server: v2.5.22, 3, 5, PCI−X IBM HS20 FC Exp Card (13N2203)20, 24 FC−SW EMC Y9, 16
8678)35, 8832)35, 8832−N1X); 6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 AX150
IBM BladeCenter HS40 (Model 8839)
138 IBM BladeCenter HS20 (Model: VMware ESX Server: v2.5.22, 3, 5, PCI−X IBM HS20 FC Exp Card (48P7061)12, 20, 24 FC−SW EMC Y9, 16
8678)35, 8832)35, 8832−N1X), 8843) 6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 AX150
139 IBM BladeCenter LS20 (Model 8850) VMware ESX Server: v2.5.22, 3, 5, PCI−X IBM HS20 FC SFF Exp Card (26K4841) for IBM FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, eServer LS2012, 20, 24 CLARiiON
4, 5, 6, 7, 8 AX150
140 HPQ Proliant BL20p (G2) VMware ESX Server: v2.5.22, 3, 5, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, BL20p (G2) 300874−B2119, 20 CLARiiON
4, 5, 6, 7, 8 AX150
141 HPQ Proliant BL25p VMware ESX Server: v2.5.22, 3, 5, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, BL25p/BL45p 381881−B2120, 50 CLARiiON
4, 5, 6, 7, 8 AX150
142 HPQ Proliant BL35p VMware ESX Server: v2.5.22, 3, 5, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, BL30p/BL35p 354054−B2119, 20 CLARiiON
4, 5, 6, 7, 8 AX150
143 HPQ Proliant BL30p VMware ESX Server: v2.5.22, 3, 5, PCI−X14 HPQ Dual−port Fibre Channel Adapter for HP Proliant FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, BL30p/BL35p 354054−B2119, 27 CLARiiON
4, 5, 6, 7, 8 AX150
144 IBM xSeries x3950/x3950E/x460 VMware ESX Server: v2.5.22, 3, 5, PCI−X26 QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
(8872, 8874)25 6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 AX150
145 IBM BladeCenter LS20 (Model 8850) VMware ESX Server: v2.5.22, 3, 5, PCI−X IBM HS20 FC Exp Card (13N2203) for IBM eServer FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, LS2012, 20, 24 CLARiiON
4, 5, 6, 7, 8 , v3.03, 6, 30, 31 , v3.03, 6, AX150
8, 30, 31

146 IBM BladeCenter HS20 (Model 8843) VMware ESX Server: v2.5.22, 3, 5, PCI−X IBM HS20 FC Exp Card (26K4841)12, 20, 24, 47 FC−SW EMC Y9, 16
6, 7, v2.5.32, 3, 5, 6, 7 , v2.5.41, 2, 3, CLARiiON
4, 5, 6, 7, 8 , v3.03, 6, 30, 31 , v3.03, 6, AX150
8, 30, 31

147 Dell PowerEdge: 1550, 255022, VMware ESX Server: v2.5.32, 3, 5, PCI Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
645023; 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
HPQ Proliant: DL360(G2)21,
DL36021, DL380(G3)21, DL58021;
IBM xSeries: x330, x335;
NEC Express 5800: 120Rf−2, 140Hd,
140Rc−4, 180Rc−4, 180Rd−4
148 NEC Express 5800: 120Rf−2, 140Hd, VMware ESX Server: v2.5.32, 3, 5, PCI NEC N8190−120 (LP1050)10, 11, 13, 17 FC−SW EMC N9
140Rc−4, 180Rd−4 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
149 NEC Express 5800 110Rg−1 VMware ESX Server: v2.5.32, 3, 5, PCI NEC N8190−120 (LP1050)10, 11, 13, 17 FC−SW EMC N9
6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 Express, CLARiiON
PCI−X AX150
150 Fujitsu Siemens Primergy RX600 S2 VMware ESX Server: v2.5.32, 3, 5, PCI−X Emulex LP1050−E10, 12, 13, 37 FC−SW EMC N9
6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
151 HPQ Proliant DL360(G4)21 VMware ESX Server: v2.5.32, 3, 5, PCI−X Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150

11/02/2006 367 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Host Storage External
No. Host System Operating System Bus Host Bus Adapter Topology Array Boot
152 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server: v2.5.32, 3, 5, PCI−X Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
2650, 4600, 6600, 6650; 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL56021, DL74021,
DL760 (G2)21, DL76021,
ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)25, xSeries x440;
NEC Express 5800: 120Lh, 120Re−1,
120Rf−1, 120Rg−2, 120Rh−2,
420Ma;
Sun: V20z, V40z
153 NEC Express 5800: 120Lh, 120Re−1, VMware ESX Server: v2.5.32, 3, 5, PCI−X NEC N8190−120 (LP1050)10, 11, 13, 17 FC−SW EMC N9
120Rf−1, 120Rg−2, 120Rh−2, 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
140He, 140Rd−4 AX150
154 Dell PowerEdge: 1650, 1750, 2600, VMware ESX Server: v2.5.32, 3, 5, PCI−X QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
2650, 4600, 6600, 6650; 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
Fujitsu Siemens Primergy: RX300 S2,
TX300 S2;
HPQ Proliant: BL40p, DL360(G3)21,
DL360(G4)21, DL56021, DL74021,
DL760 (G2)21, DL76021,
ML570(G2)21, ML570(G3)21;
IBM: eServer 326 (Model 8848),
xSeries x235, xSeries x255, xSeries
x360, xSeries x365, xSeries
x3850/x366 (8863)25, xSeries x440;
NEC Express 5800 120Lh;
Sun: V20z, V40z
155 IBM xSeries x3950/x3950E/x460 VMware ESX Server: v2.5.32, 3, 5, PCI−X26 Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
(8872, 8874)25 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 CLARiiON
AX150
156 HPQ Proliant: DL380(G4)21, VMware ESX Server: v2.5.32, 3, 5, PCI, Emulex LP1050Ex−E10, 11, 12, 13 FC−SW EMC N9
DL580(G3)21 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 PCI−X CLARiiON
AX150
157 HPQ Proliant: DL380(G2)21, VMware ESX Server: v2.5.32, 3, 5, PCI, Emulex: LP1050−E10, 13, 18, LP982−E10, 13 FC−SW EMC N9
DL380(G4)21, DL38021, DL38521, 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 PCI−X CLARiiON
DL580(G2)21, DL580(G3)21, AX150
DL58521, ML370(G3)21,
ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
158 HPQ Proliant: DL380(G2)21, VMware ESX Server: v2.5.32, 3, 5, PCI, QLogic QLA2340−E−SP20, 24 FC−SW EMC Y9, 16
DL380(G4)21, DL38021, DL38521, 6, 7, v2.5.41, 2, 3, 4, 5, 6, 7, 8 PCI−X CLARiiON
DL580(G2)21, DL580(G3)21, AX150
DL58521, ML370(G3)21,
ML370(G4)21;
IBM: eServer 325 (Model 8835),
xSeries x345 (8670), xSeries x445
(8870)
159 HPQ Proliant BL460c: (416653−B21), VMware ESX Server: v3.0.12, 3, 6, PCI−X HPQ Emulex LPe1105−HP 4Gb FC HBA for HP FC−SW EMC Y61, 62
(416654−B21), (416655−B21), 8, 30, v3.02, 3, 6, 8, 30 c−Class Bladesystem (403621−B21)29, 59, 60 CLARiiON
(416656−B21), (432636−B21); AX150
HPQ Proliant BL480c: (416666−B21),
(416667−B21), (416668−B21),
(416669−B21)
160 IBM BladeCenter HS20 (Model: VMware ESX Server: v3.03, 6, 30, PCI−X IBM Emulex LP1005DC FC Exp Card12, 34 FC−SW EMC Y9, 16
8832)35, 8832−N1X), 8843); 31, v3.03, 6, 8, 30, 31 CLARiiON
AX150
IBM BladeCenter: HS40 (Model
8839), LS20 (Model 8850)
161 IBM BladeCenter HS20 (Model: VMware ESX Server: v3.03, 6, 30, PCI−X IBM HS20 FC Exp Card (13N2203)20, 24 FC−SW EMC Y9, 16
8832)35, 8832−N1X); 31, v3.03, 6, 8, 30, 31 CLARiiON
AX150
IBM BladeCenter HS40 (Model 8839)
162 IBM BladeCenter HS20 (Model: VMware ESX Server: v3.03, 6, 30, PCI−X IBM HS20 FC Exp Card (48P7061)12, 20 FC−SW EMC Y9, 16
8832)35, 8832−N1X), 8843) 31, v3.03, 6, 8, 30, 31 CLARiiON
AX150
163 IBM BladeCenter LS20 (Model 8850) VMware ESX Server: v3.03, 6, 30, PCI−X IBM HS20 FC SFF Exp Card (26K4841) for IBM FC−SW EMC Y9, 16
31, v3.03, 6, 8, 30, 31 eServer LS2012, 20 CLARiiON
AX150
1. Replicas of application data volumes of physical (native) servers created using SnapView, MirrorView and SAN Copy can be presented to a VMware ESX Server. These replicas
configured on the VMware ESX server must be Raw Device Mapping only (VMFS is not supported). Replicas of application data volumes configured as Raw Device Mapping volumes
on a VMware ESX server can also be presented to a physical (native) server.
Replication of Operating System volumes and application volumes from a physical to virtual or virtual to physical environment using CLARiiON replication software is not supported at
this time. Replication of Operating System volumes, application volumes and application data volumes from a virtual to virtual environment using CLARiiON replication software is
supported.
2. Beginning with ESX Server v2.5.0 Navisphere components are supported as follows:
Navi Agent and Server Utility at the console level only;
Array Initialization Utility and CLI at both the console and VM levels;
Browser interface to Navisphere Express or Navi Manager at the VM level only.
3. Supported with VirtualCenter VMotion.
4. Replication of both VMFS and Raw Device Mapping (RDM) volumes is supported using CLARiiON replication software (SnapView, MirrorView and SAN Copy) starting with Release 19.
The OS/application as well as application data can be replicated using CLARiiON replication software.
Note:
1) The virtual disks in a VMFS volume must be in persistent−mode during the replication process.
2) CLARiiON VSS provider is not supported on VMFS volumes.
3) If replicating an entire VMFS volume that contains a number of virtual disks on a single CLARiiON LUN, the granularity of replication is the entire LUN with all its virtual disks.
4) Use the consistency technology available on SnapView/MirrorView, when making copies of VMFS volumes that span multiple CLARiiON LUNs.
5) The VMFS replica must be assigned to a different ESX server. The target ESX server must not already have access to the original source VMFS volume.

11/02/2006 368 CLARiiON AX150


CLARiiON AX150

6) For source LUNs configured as RDM volumes, the replica can be presented to the same ESX server but to a different Virtual Machine unless the guest OS is qualified to allow same
host access.
7) RDM volumes cannot be created when the ESX server is booting from SAN. VMFS volumes can be created when the ESX server is booting from SAN. If ESX server is not booting
from SAN, Virtual Machines can be configured using either VMFS or RDM volumes.
8) Ensure the snapshot is activated or clone fractured before presenting them to an ESX server.
9) When replicating OS images, you will only have a crash consistent copy if the Virtual Machines are not shutdown during the replication process.
10) Please note that replicating a suspended Virtual Machine will result in a crash consistent copy.
11) Admsnap, Admhost utilities must be installed only on Virtual Machines. With admsnap or admhost installed on the Virtual Machine, most of the commands issued on VMFS volumes
will fail, since VMFS volumes do not support scsi pass−through commands to talk to the CLARiiON. Use Navisphere Manager or Navisphere CLI instead. The only commands that will
work with VMFS volumes are admsnap flush and admhost flush. Admsnap is not supported under Netware Virtual Machines with either RDM or VMFS volumes.
5. Supported with VMFS and VMFS−2.
6. PowerPath is not supported on VMWare ESX. The VMWare ESX native failover functionality is supported.
7. While using an AX100−series storage system managed using Navisphere Express with VMware ESX Server, Snapshots cannot be assigned to the ESX server.
8. Replication of both VMFS and Raw Device Mapping (RDM) volumes is supported using Symmetrix replication software (SRDF and TimeFinder). Please refer to the solution guide,
'VMware ESX Server Using EMC Symmetrix Storage Systems' for details.
Replicas of application data volumes of physical (native) servers created using Symmetrix replication software can be presented to a VMware ESX Server. Note:
1) Replication of Operating System volumes and application volumes from a virtual to physical environment using Symmetrix replication software is not supported at this time.
2) Replication of Operating System volumes, application volumes and application data volumes from a virtual to virtual environment using Symmetrix replication software is supported.
9. Virtual machines running on VMWare ESX are supported booting from the array.
10. BIOS 1.70a3 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
11. Firmware Version 1.91a5 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
12. SNIA HBA API Supported.
13. Driver Version 2.01g This driver is included in the VMware ESX kernel.
14. Dual port PCI−X fibre channel mezzanine card option is embedded. No PCI/PCI−X slots available.
15. BIOS 1.70a3
16. VMWare ESX Server itself is supported booting from external array.
17. EMC supported drivers, firmware, and boot BIOS can be downloaded from http://www.emulex.com in the EMC section, by obtaining the supported driver for the Emulex LP1050−E.
18. Firmware Version 1.91a5
19. BIOS 1.45 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Driver Version 7.04.00 This driver is included in the VMware ESX kernel.
21. HPQ (Compaq) Proliant server models that are not listed in the ESM but are only differentiated from supported models by an "R" designator, are rack−mountable servers and are
supported.
22. PowerEdge 2550 and PowerVault 775N support a maximum of 2 Emulex HBAs at one time and the total PCI power cannot exceed 20 Watts.
23. Dell PowerEdge 6450 does not support Emulex LP9802/DC HBAs.
24. BIOS 1.47 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Support for 4Gb fibre channel HBAs requires an IBM SPORE to be submitted to IBM.
26. Accepts PCI−X 1.0 and 2.0 HBAs.
27. Driver Version 7.04.00 Requires BIOS 1.45 (HP BL30p specific) available from QLogic at http://www.qlogic.com This driver is included in the VMware ESX kernel.
28. Firmware Version 2.50a6
29. Driver Version 7.3.2 This driver is included in the VMware ESX kernel.
30. Supported with VMFS−3.
31. Beginning with ESX Server v2.5.0 Navisphere components are supported as follows:
Navi Agent and Server Utility at the console level only;
Array Initialization Utility and CLI at both the console and VM levels;
Browser interface to Navi Manager at the VM level only.
32. BIOS 1.08
33. Driver Version 7.07.00 This driver is included in the VMware ESX kernel.
34. Driver Version 7.1.14 This driver is included in the VMware ESX kernel.
35. EMC VolumeLogix Software required for multiple BladeServers when direct−attached to EMC Symmetrix storage.
36. Requires BIOS 1.05 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
37. Firmware Version 1.91a1
38. FCode Value 1.70a3
39. Requires BIOS 1.47 available in the EMC−approved section of the QLogic website at http://www.qlogic.com
40. BIOS 1.70a3 This driver is included in the VMware ESX kernel. Available in the EMC−approved section of the Emulex website. http://www.emulex.com
41. Firmware Version 2.50a6 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
42. This HBA is equivalent to the QLogic QLA2340.
43. 4GB HBAs are not supported in this server. RPQs for 4GB HBAs will not be approved for this server.
44. BIOS 1.05 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
45. Firmware Version 2.10a9 Available in the EMC−approved section of the Emulex website. http://www.emulex.com
46. BIOS 1.17
47. Firmware Version 3.01.18
48. This dual port HBA is only supported on DELL PE 6850 in the right−most slot (seen from the rear of the server chassis) marked "FC"
49. BIOS 1.06 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
50. BIOS 1.48 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
51. This driver is included in the VMware ESX kernel.
52. BladeCenter support for Windows 2000 operating systems requires an IBM SPORE to be submitted to IBM, then if approved by IBM, be subsequently submitted to EMC as
an RPQ for review.
53. Driver Version 7.07.04 This driver is included in the VMware ESX kernel.
54. BIOS 1.47
55. BIOS 1.12
56. BIOS 1.16
57. BX6xx−series systems use an embedded fibre channel controller. Contact Fujitsu Siemens to acquire the proper BIOS for the embedded fibre channel controller.
58. FSC Fibre Channel module. Dual channel 2GBit/s HBA for BX6xx−series blade servers only.
59. BIOS 6.00a1
60. Firmware Version 2.50a8
61. Booting from the SAN with PowerPath is supported. Refer to the Path Management Software section for supported versions of PowerPath.
62. VxVM is not supported on servers booting from the array.
63. Only supported in a boot from SAN configuration.

Cluster Software
Microsoft Windows 2000
EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Microsoft Windows 2000


Cluster Max #
No. Operating System Software Nodes Infrastructure Software Server LVM Storage Array Comments
1 Microsoft Windows 2000: Advanced Microsoft HA: 2 EMC PowerPath: 4.3.1, Veritas VxVM: 4.0, 4.1, 4.2 (Storage EMC See3
Server SP4, Server SP4 MSCS1, 2 4.4.1, 4.5.0, 4.5.1 Foundation), 4.3 (Storage Foundation) CLARiiON
AX150
1. Cluster software is not supported on Stratus ftServers.
2. Valid MSCS quorum resource configurations include both 'shared disk quorum' and 'majority node set' schemes.
3. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

11/02/2006 369 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Microsoft Windows 2003 [x64]


Cluster Max # Infrastructure Storage
No. Operating System Software Nodes Software Server LVM Array Comments
1 Microsoft Windows 2003 [x64]: DataCenter, DataCenter R2, Microsoft HA: 8 EMC PowerPath: Veritas VxVM: 4.0, 4.1, 4.2 EMC See2
Enterprise Edition, Enterprise Edition R2, Storage Server MSCS1 4.4.1, 4.5.0, 4.5.1, (Storage Foundation), 4.3 (Storage CLARiiON
Enterprise Edition R2 4.6.0, 4.6.1 Foundation) AX150
1. Valid MSCS quorum resource configurations include both 'shared disk quorum' and 'majority node set' schemes.
2. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

Microsoft Windows 2003 [x86]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Microsoft Windows 2003 [x86]


Cluster Max # Infrastructure Storage
No. Operating System Software Nodes Software Server LVM Array Comments
1 Microsoft Windows 2003 [x86]: DataCenter, DataCenter R2, DataCenter SP1, Microsoft HA: 8 EMC PowerPath: Veritas VxVM: 4.0, EMC See3
Enterprise Edition, Enterprise Edition R2, Enterprise Edition SP1, Storage Server, MSCS1, 2 4.3.1, 4.4.1, 4.1, 4.2 (Storage CLARiiON
Storage Server Enterprise Edition, Storage Server Enterprise Edition R2, Storage 4.5.0, 4.5.1, Foundation), 4.3 AX150
Server Enterprise Edition SP1, Storage Server R2, Storage Server SP1 4.6.0, 4.6.1 (Storage Foundation)
1. Cluster software is not supported on Stratus ftServers.
2. Valid MSCS quorum resource configurations include both 'shared disk quorum' and 'majority node set' schemes.
3. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

Red Hat RHEL [32−Bit]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Red Hat RHEL [32−Bit]


Infrastructure
No. Operating System Cluster Software Software Storage Array
1 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 NEC ClusterPro SE 3, Express EMC PowerPath EMC CLARiiON
AS/ES v2.4.21−40.EL Cluster 3 4.3.4 AX150
2 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ NEC ClusterPro SE 3, Express EMC PowerPath EMC CLARiiON
AS/ES v2.6.9−34.0.2.EL Cluster 3 4.5.1 AX150

Red Hat RHEL [EM64T]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Red Hat RHEL [EM64T]


Infrastructure
No. Operating System Cluster Software Software Storage Array
1 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 NEC ClusterPro SE 3, Express EMC PowerPath EMC CLARiiON
AS/ES v2.4.21−40.EL Cluster 3 4.3.4 AX150
2 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ NEC ClusterPro SE 3, Express EMC PowerPath EMC CLARiiON
AS/ES v2.6.9−34.0.2.EL Cluster 3 4.5.1 AX150

Red Hat RHEL [IA64]


EMC has qualified the following cluster software. Please refer to the Base Connectivity table(s) for information concerning server models, HBAs, drivers,
firmware, operating system requirements and other special notes.

Red Hat RHEL [IA64]


Infrastructure
No. Operating System Cluster Software Software Storage Array
1 Red Hat RHEL [IA64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ NEC ClusterPro SE 3, Express EMC PowerPath EMC CLARiiON
AS/ES v2.6.9−34.0.2.EL Cluster 3 4.5.1 AX150

Fibre Connectivity: Switch


Haansoft Asianux Server 2.0 [32−Bit]

11/02/2006 370 CLARiiON AX150


CLARiiON AX150

Haansoft Asianux Server 2.0 [32−Bit]


Host
Operating Bus Luns/Storage Port Storage
No. System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Dell Dell 15 15 256 256 Y EMC
Asianux Server 2342M Brocade: CLARiiON
2.0 [32−Bit] GA 1/2Gb FC AX150
v2.6.9−11.19AX Switch
Module
(SW3014),
4Gb FC
Switch
Module
(SW4016);
Dell
McDATA
FC Switch
Module:
(SW4314),
(SW4416);
Dell
Optical
Pass−thru
Module
(J6780)

Haansoft Asianux Server 2.0 [AMD64]

Haansoft Asianux Server 2.0 [AMD64]


Host
Operating Bus Luns/Storage Port Storage
No. System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Dell Dell 15 15 256 256 Y EMC
Asianux Server 2342M Brocade: CLARiiON
2.0 [AMD64] GA 1/2Gb FC AX150
v2.6.9−11.19AX Switch
Module
(SW3014),
4Gb FC
Switch
Module
(SW4016);
Dell
McDATA
FC Switch
Module:
(SW4314),
(SW4416);
Dell
Optical
Pass−thru
Module
(J6780)

Haansoft Asianux Server 2.0 [EM64T]

Haansoft Asianux Server 2.0 [EM64T]


Host
Operating Bus Luns/Storage Port Storage
No. System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Dell Dell 15 15 256 256 Y EMC
Asianux Server 2342M Brocade: CLARiiON
2.0 [EM64T] GA 1/2Gb FC AX150
v2.6.9−11.19AX Switch
Module
(SW3014),
4Gb FC
Switch
Module
(SW4016);
Dell
McDATA
FC Switch
Module:
(SW4314),
(SW4416);
Dell
Optical
Pass−thru
Module
(J6780)

Haansoft Linux 2005 Server Asianux Inside [32−Bit]

11/02/2006 371 CLARiiON AX150


CLARiiON AX150

Haansoft Linux 2005 Server Asianux Inside [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Linux 2005 Server Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
Asianux Inside [32−Bit] Module (SW3014), 4Gb FC Switch CLARiiON
v2.4.21−37.18AX Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
2 Haansoft Linux 2005 Server Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
Asianux Inside [32−Bit] LP982−E; CLARiiON
v2.4.21−37.18AX QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
3 Haansoft Linux 2005 Server Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Asianux Inside [32−Bit] LP1050−E, DS−4700M; CLARiiON
v2.4.21−37.18AX LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 Haansoft Linux 2005 Server Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Asianux Inside [32−Bit] LP1050−E, DS−4700M; CLARiiON
v2.4.21−37.18AX LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
5 Haansoft Linux 2005 Server NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
Asianux Inside [32−Bit] (LP1050) CLARiiON
v2.4.21−37.18AX EMC Connectrix: DS−220B−FF−D1, AX150
DS−4400M, DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Haansoft Linux 2005 Server Asianux Inside [AMD64]

Haansoft Linux 2005 Server Asianux Inside [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Linux 2005 Server Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
Asianux Inside [AMD64] Module (SW3014), 4Gb FC Switch CLARiiON
v2.4.21−37.18AX Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
2 Haansoft Linux 2005 Server Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
Asianux Inside [AMD64] LP982−E; CLARiiON
v2.4.21−37.18AX QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
3 Haansoft Linux 2005 Server Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Asianux Inside [AMD64] LP1050−E, DS−4700M; CLARiiON
v2.4.21−37.18AX LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 Haansoft Linux 2005 Server Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Asianux Inside [AMD64] LP1050−E, DS−4700M; CLARiiON
v2.4.21−37.18AX LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
5 Haansoft Linux 2005 Server NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
Asianux Inside [AMD64] (LP1050) CLARiiON
v2.4.21−37.18AX EMC Connectrix: DS−220B−FF−D1, AX150
DS−4400M, DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Haansoft Linux 2005 Server Asianux Inside [EM64T]

11/02/2006 372 CLARiiON AX150


CLARiiON AX150

Haansoft Linux 2005 Server Asianux Inside [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Haansoft Linux 2005 Server Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
Asianux Inside [EM64T] Module (SW3014), 4Gb FC Switch CLARiiON
v2.4.21−37.18AX Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
2 Haansoft Linux 2005 Server Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
Asianux Inside [EM64T] LP982−E; CLARiiON
v2.4.21−37.18AX QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
3 Haansoft Linux 2005 Server Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Asianux Inside [EM64T] LP1050−E, DS−4700M; CLARiiON
v2.4.21−37.18AX LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 Haansoft Linux 2005 Server Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Asianux Inside [EM64T] LP1050−E, DS−4700M; CLARiiON
v2.4.21−37.18AX LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
5 Haansoft Linux 2005 Server NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
Asianux Inside [EM64T] (LP1050) CLARiiON
v2.4.21−37.18AX EMC Connectrix: DS−220B−FF−D1, AX150
DS−4400M, DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Microsoft Windows 2000

Microsoft Windows 2000


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Microsoft Windows 2000 Dell 2362M EMC Connectrix: DS−4400M, 15 15 256 128, 256 Y EMC
Advanced Server: SP4, SP42; DS−4700M; CLARiiON
AX150
Microsoft Windows 2000 McDATA: ES−4400, ES−4700
Server SP4
2 Microsoft Windows 2000 Emulex LP1050Ex−E EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Advanced Server: SP4, SP42; DS−4700M; CLARiiON
AX150
Microsoft Windows 2000 McDATA: ES−4400, ES−4700
Server SP4
3 Microsoft Windows 2000 Emulex: LPe111−E, LPe1150−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Advanced Server: SP4, SP42; DS−4700M; CLARiiON
HPQ: A7560A (LP1050Ex), AX150
Microsoft Windows 2000 A8002A/FC2142SR (LPe1150); McDATA: ES−4400, ES−4700
Server SP4
NEC: N8190−127 (LPe1150),
N8803−031 (QLA2310F);
QLogic QLE220−E−SP
4 Microsoft Windows 2000 Emulex: LP1050−E, LP982−E; EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
Advanced Server: SP4, SP42; DS−4700M; CLARiiON
HPQ: A7298A (LP982), A7388A AX150
Microsoft Windows 2000: (LP1050), FCA2214 (QLA2340), McDATA: ES−4400, ES−4700
Datacenter SP4, Server SP4 FCA2408 (LP982);
QLogic: QLA2310F−E−SP,
QLA2340−E−SP;
Unisys FCH752313−PCX (LP1050)
5 Microsoft Windows 2000 Emulex: LP1150−E, LP982−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Advanced Server: SP4, SP42; DS−4700M; CLARiiON
IBM 39M5894 (QLA2460); AX150
Microsoft Windows 2000: QLogic: QLA2310F−E−SP, McDATA: ES−4400, ES−4700
Datacenter SP4, Server SP4 QLA2340−E−SP, QLA2460−E−SP,
QLE2460−E−SP, QLE2462−E−SP
6 Microsoft Windows 2000 NEC N8190−120 (LP1050); EMC Connectrix: DS−4400M, 15 15 256 128, 256 Y EMC
Advanced Server: SP4, SP42; QLogic QLE2360−E−SP DS−4700M; CLARiiON
AX150
Microsoft Windows 2000: McDATA: ES−4400, ES−4700
Datacenter SP4, Server SP4
7 Microsoft Windows 2000 IBM 19K1246 (QLA2310) EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Datacenter SP4 DS−4700M; CLARiiON
AX150
McDATA: ES−4400, ES−4700

11/02/2006 373 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2000


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
8 Microsoft Windows 2000: Emulex LP1050−E; EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
Advanced Server SP4, HPQ: A7298A (LP982), A7388A DS−4700M; CLARiiON
Datacenter SP4, Server SP4 (LP1050), FCA2214 (QLA2340), AX150
FCA2408 (LP982); McDATA: ES−4400, ES−4700
IBM 24P0960 (QLA2340)
9 Microsoft Windows 2000: Dell 2342M Dell: Brocade 1/2Gb FC Switch 15 15 256 256 Y EMC
Advanced Server SP4, Server Module (SW3014), McDATA FC CLARiiON
SP4 Switch Module (SW4314) AX150
10 Microsoft Windows 2000: Dell: 2342M, LPe1105−M, QME2462 Dell: Brocade 4Gb FC Switch 15 15 256 256 Y EMC
Advanced Server SP4, Server Module (SW4016), McDATA FC CLARiiON
SP4 Switch Module (SW4416) AX150
11 Microsoft Windows 2000: Emulex: LP101−E, LP982−E; Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
Advanced Server SP4, Server CLARiiON
SP4 QLogic: QLA200−E−SP, EMC Connectrix: 3250−VL2E4, AX150
QLA210−E−SP, QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
12 Microsoft Windows 2000: IBM 39M5894 (QLA2460); Brocade Silkworm: 205E, 207E; 15 15 256 256 Y EMC
Advanced Server SP4, Server QLogic: QLA2460−E−SP, CLARiiON
SP4 QLE220−E−SP, QLE2460−E−SP, EMC Connectrix: 3250−VL2E4, AX150
QLE2462−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
13 Microsoft Windows 2000: QLogic QLE2360−E−SP Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
Advanced Server SP4, Server CLARiiON
SP4 EMC Connectrix: 3250−VL2E4, AX150
DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. Windows 2000 hosts running less than SP4 could be susceptible to data loss during LUN expansion operations. This issue is corrected by Microsoft in SP4, or by applying hotfix 327020.
See EMC Solution IS emc73538 and Microsoft Knowledge Base article 327020 for more information.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
4. This switch is offered by Dell as the Brocade VL2 LC.

Microsoft Windows 2003 [x64]

Microsoft Windows 2003 [x64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Microsoft Windows Dell 2342M Dell: Brocade 1/2Gb FC 15 15 256 256 Y EMC
2003 [x64] Enterprise: Switch Module (SW3014), CLARiiON
Edition, Edition R2; McDATA FC Switch AX150
Module (SW4314)
Microsoft Windows
2003 [x64] Standard:
Edition, Edition R2
2 Microsoft Windows Dell 2362M; EMC Connectrix: 15 15 256 128, 256 Y EMC
2003 [x64] Enterprise: NEC N8190−120 (LP1050); DS−4400M, DS−4700M; CLARiiON
Edition, Edition R2; QLogic QLE2360−E−SP AX150
McDATA: ES−4400,
Microsoft Windows ES−4700
2003 [x64] Standard:
Edition, Edition R2
3 Microsoft Windows Dell: 2342M, LPe1105−M, QME2462 Dell: Brocade 4Gb FC 15 15 256 256 Y EMC
2003 [x64] Enterprise: Switch Module (SW4016), CLARiiON
Edition, Edition R2; McDATA FC Switch AX150
Module (SW4416)
Microsoft Windows
2003 [x64] Standard:
Edition, Edition R2
4 Microsoft Windows Emulex LP1150−E; EMC Connectrix: 15 15 256 256 Y EMC
2003 [x64] Enterprise: HPQ: A7298A (LP982), A7388A DS−4400M, DS−4700M; CLARiiON
Edition, Edition R2; (LP1050), A7560A (LP1050Ex), AX150
A8002A/FC2142SR (LPe1150), McDATA: ES−4400,
Microsoft Windows FCA2214 (QLA2340), FCA2408 ES−4700
2003 [x64] Standard: (LP982);
Edition, Edition R2
IBM: 19K1246 (QLA2310), 24P0960
(QLA2340), 39M5894 (QLA2460);
NEC: N8190−127 (LPe1150),
N8803−031 (QLA2310F);
QLogic QLA2460−E−SP
5 Microsoft Windows Emulex LP982−E; Brocade Silkworm: 205E, 15 15 256 128 Y EMC
2003 [x64] Enterprise: QLogic QLA2340−E−SP 207E; CLARiiON
Edition, Edition R2; AX150
EMC Connectrix:
Microsoft Windows 3250−VL2E2,
2003 [x64] Standard: DS−220B−FF−D1,
Edition, Edition R2 DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E

11/02/2006 374 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
6 Microsoft Windows Emulex: LP1050−E, LP1050Ex−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
2003 [x64] Enterprise: LP982−E; DS−4400M, DS−4700M; CLARiiON
Edition, Edition R2; AX150
HPQ: A7298A (LP982), A7388A McDATA: ES−4400,
Microsoft Windows (LP1050), FCA2214 (QLA2340), ES−4700
2003 [x64] Standard: FCA2408 (LP982);
Edition, Edition R2
QLogic: QLA2310F−E−SP,
QLA2340−E−SP;
Unisys FCH752313−PCX (LP1050)
7 Microsoft Windows HPQ: A7298A (LP982), A7388A Brocade Silkworm: 205E, 15 15 256 223, 256 Y EMC
2003 [x64] Enterprise: (LP1050), FCA2214 (QLA2340), 207E; CLARiiON
Edition, Edition R2; FCA2408 (LP982) AX150
EMC Connectrix
Microsoft Windows DS−220B−FF−D1;
2003 [x64] Standard: McDATA ES−43003
Edition, Edition R2
8 Microsoft Windows HPQ: A7298A (LP982), A7388A Brocade Silkworm: 205E, 15 15 256 256 Y EMC
2003 [x64] Enterprise: (LP1050), FCA2214 (QLA2340), 207E; CLARiiON
Edition, Edition R2; FCA2408 (LP982); AX150
EMC Connectrix
Microsoft Windows IBM: 24P0960 (QLA2340), 39M5894 DS−220B−FF−D1;
2003 [x64] Standard: (QLA2460); McDATA ES−43003
Edition, Edition R2
QLogic QLA2460−E−SP
9 Microsoft Windows IBM 39M5894 (QLA2460); EMC Connectrix: 15 15 256 256 Y EMC
2003 [x64] Enterprise: QLogic QLA2460−E−SP 3250−VL2E2, CLARiiON
Edition, Edition R2; DS−8B2−0DL; AX150
Microsoft Windows QLogic SANBox:
2003 [x64] Standard: SB1404−10AJ−E,
Edition, Edition R2 SB3050−08A−E
10 Microsoft Windows NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
2003 [x64] Enterprise: QLogic QLE2360−E−SP 207E; CLARiiON
Edition, Edition R2; AX150
EMC Connectrix
Microsoft Windows DS−220B−FF−D1;
2003 [x64] Standard: McDATA ES−43003
Edition, Edition R2
11 Microsoft Windows QLogic QLE2360−E−SP EMC Connectrix: 15 15 256 128, 256 Y EMC
2003 [x64] Enterprise: 3250−VL2E2, CLARiiON
Edition, Edition R2; DS−8B2−0DL; AX150
Microsoft Windows QLogic SANBox:
2003 [x64] Standard: SB1404−10AJ−E,
Edition, Edition R2 SB3050−08A−E
12 Microsoft Windows Emulex: LP1050−E, LP982−E, EMC Connectrix: 15 15 256 256 Y EMC
2003 [x64] Enterprise: LPe111−E, LPe1150−E; DS−4400M, DS−4700M; CLARiiON
Edition, Edition R2; AX150
QLogic: QLA2310F−E−SP, McDATA: ES−4400,
Microsoft Windows QLA2340−E−SP, QLE220−E−SP ES−4700
2003 [x64] Standard:
Edition, Edition R2;
Microsoft Windows
2003 [x64] Storage
Server: Enterprise
Edition R2, Standard
Edition R2
13 Microsoft Windows QLogic QLE220−E−SP Brocade Silkworm: 205E, 15 15 256 256 Y EMC
2003 [x64] Enterprise: 207E; CLARiiON
Edition, Edition R2; AX150
EMC Connectrix:
Microsoft Windows 3250−VL2E2,
2003 [x64] Standard: DS−220B−FF−D1,
Edition, Edition R2; DS−8B2−0DL;
Microsoft Windows McDATA ES−43003;
2003 [x64] Storage QLogic SANBox:
Server: Enterprise SB1404−10AJ−E,
Edition R2, Standard SB3050−08A−E
Edition R2
14 Microsoft Windows QLogic: QLE2460−E−SP, Brocade Silkworm: 205E, 15 15 256 256 Y EMC
2003 [x64] Enterprise: QLE2462−E−SP 207E; CLARiiON
Edition, Edition R2; AX150
EMC Connectrix:
Microsoft Windows 3250−VL2E2,
2003 [x64] Standard: DS−220B−FF−D1,
Edition, Edition R2; DS−4400M, DS−4700M,
DS−8B2−0DL;
Microsoft Windows
2003 [x64] Storage McDATA: ES−43003,
Server: Enterprise ES−4400, ES−4700;
Edition R2, Standard
Edition R2; QLogic SANBox:
SB1404−10AJ−E,
Microsoft Windows SB3050−08A−E
2003 [x64] Unified Data
Storage Server
15 Microsoft Windows Emulex LP1050Ex−E; EMC Connectrix: 15 15 256 256 Y EMC
2003 [x64] Storage QLogic QLE2360−E−SP DS−4400M, DS−4700M; CLARiiON
Server: Enterprise AX150
Edition R2, Standard McDATA: ES−4400,
Edition R2 ES−4700

11/02/2006 375 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
16 Microsoft Windows Emulex: LP1050−E, LP1050Ex−E, Brocade Silkworm: 205E, 15 15 256 256 Y EMC
2003 [x64] Storage LP982−E, LPe111−E, LPe1150−E; 207E; CLARiiON
Server: Enterprise AX150
Edition R2, Standard QLogic: QLA2340−E−SP, EMC Connectrix:
Edition R2 QLE2360−E−SP 3250−VL2E2,
DS−220B−FF−D1,
DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

Microsoft Windows 2003 [x86]

Microsoft Windows 2003 [x86]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Microsoft Windows 2003 [x86] Enterprise: Dell 2342M Dell: Brocade 1/2Gb 15 15 256 256 Y EMC
Edition, Edition R2, Edition SP1; FC Switch Module CLARiiON
(SW3014), McDATA AX150
Microsoft Windows 2003 [x86] Standard: FC Switch Module
Edition, Edition R2, Edition SP1 (SW4314)
2 Microsoft Windows 2003 [x86] Enterprise: Dell 2362M EMC Connectrix: 15 15 256 128, 256 Y EMC
Edition, Edition R2, Edition SP1; DS−4400M, CLARiiON
DS−4700M; AX150
Microsoft Windows 2003 [x86] Standard:
Edition, Edition R2, Edition SP1 McDATA: ES−4400,
ES−4700
3 Microsoft Windows 2003 [x86] Enterprise: Dell: 2342M, Dell: Brocade 4Gb FC 15 15 256 256 Y EMC
Edition, Edition R2, Edition SP1; LPe1105−M, QME2462 Switch Module CLARiiON
(SW4016), McDATA AX150
Microsoft Windows 2003 [x86] Standard: FC Switch Module
Edition, Edition R2, Edition SP1 (SW4416)
4 Microsoft Windows 2003 [x86] Enterprise: Emulex LP1050Ex−E; EMC Connectrix: 15 15 256 223, 256 Y EMC
Edition, Edition R2, Edition SP1; HPQ: A7298A (LP982), DS−4400M, CLARiiON
FCA2214 (QLA2340), DS−4700M; AX150
Microsoft Windows 2003 [x86] Standard: FCA2408 (LP982)
Edition, Edition R2, Edition SP1 McDATA: ES−4400,
ES−4700
5 Microsoft Windows 2003 [x86] Enterprise: Emulex: LP101−E, Brocade Silkworm: 15 15 256 128 Y EMC
Edition, Edition R2, Edition SP1; LP982−E; 205E, 207E; CLARiiON
AX150
Microsoft Windows 2003 [x86] Standard: QLogic: EMC Connectrix:
Edition, Edition R2, Edition SP1 QLA200−E−SP, 3250−VL2E2,
QLA210−E−SP, DS−220B−FF−D3,
QLA2340−E−SP DS−8B2−0DL;
McDATA ES−43001;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
6 Microsoft Windows 2003 [x86] Enterprise: HPQ: A7298A (LP982), Brocade Silkworm: 15 15 256 223, 256 Y EMC
Edition, Edition R2, Edition SP1; A7388A (LP1050), 205E, 207E; CLARiiON
FCA2214 (QLA2340), AX150
Microsoft Windows 2003 [x86] Standard: FCA2408 (LP982) EMC Connectrix
Edition, Edition R2, Edition SP1 DS−220B−FF−D3;
McDATA ES−43001
7 Microsoft Windows 2003 [x86] Enterprise: HPQ: A7298A (LP982), Brocade Silkworm: 15 15 256 256 Y EMC
Edition, Edition R2, Edition SP1; A7388A (LP1050), 205E, 207E; CLARiiON
FCA2214 (QLA2340), AX150
Microsoft Windows 2003 [x86] Standard: FCA2408 (LP982); EMC Connectrix
Edition, Edition R2, Edition SP1 DS−220B−FF−D3;
IBM 24P0960 McDATA ES−43001
(QLA2340)
8 Microsoft Windows 2003 [x86] Enterprise: HPQ: A7298A (LP982), EMC Connectrix: 15 15 256 256 Y EMC
Edition, Edition R2, Edition SP1; A7560A (LP1050Ex), DS−4400M, CLARiiON
FCA2214 (QLA2340), DS−4700M; AX150
Microsoft Windows 2003 [x86] Standard: FCA2408 (LP982);
Edition, Edition R2, Edition SP1 McDATA: ES−4400,
IBM: 19K1246 ES−4700
(QLA2310), 24P0960
(QLA2340);
NEC N8803−031
(QLA2310F)
9 Microsoft Windows 2003 [x86] Enterprise: NEC N8190−120 Brocade Silkworm: 15 15 256 128, 256 Y EMC
Edition, Edition R2, Edition SP1; (LP1050); 205E, 207E; CLARiiON
QLogic AX150
Microsoft Windows 2003 [x86] Standard: QLE2360−E−SP EMC Connectrix
Edition, Edition R2, Edition SP1 DS−220B−FF−D3;
McDATA ES−43001
10 Microsoft Windows 2003 [x86] Enterprise: QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
Edition, Edition R2, Edition SP1; QLE2360−E−SP 3250−VL2E2, CLARiiON
DS−8B2−0DL; AX150
Microsoft Windows 2003 [x86] Standard:
Edition, Edition R2, Edition SP1 QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E

11/02/2006 376 CLARiiON AX150


CLARiiON AX150

Microsoft Windows 2003 [x86]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
11 Microsoft Windows 2003 [x86] Enterprise: Emulex: LPe111−E, EMC Connectrix: 15 15 256 256 Y EMC
Edition, Edition R2, Edition SP1; LPe1150−E; DS−4400M, CLARiiON
DS−4700M; AX150
Microsoft Windows 2003 [x86] Standard: HPQ
Edition, Edition R2, Edition SP1; A8002A/FC2142SR McDATA: ES−4400,
(LPe1150); ES−4700
Microsoft Windows 2003 [x86] Storage: NEC N8190−127
Server, Server SP1 (LPe1150);
QLogic QLE220−E−SP
12 Microsoft Windows 2003 [x86] Enterprise: IBM 39M5894 Brocade Silkworm: 15 15 256 256 Y EMC
Edition, Edition R2, Edition SP1; (QLA2460); 205E, 207E; CLARiiON
QLogic: AX150
Microsoft Windows 2003 [x86] Standard: QLA2460−E−SP, EMC Connectrix:
Edition, Edition R2, Edition SP1; QLE220−E−SP, 3250−VL2E2,
QLE2460−E−SP, DS−220B−FF−D3,
Microsoft Windows 2003 [x86] Storage: QLE2462−E−SP DS−8B2−0DL;
Server, Server SP1
McDATA ES−43001;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
13 Microsoft Windows 2003 [x86] Storage: EMC Integrated for Brocade Silkworm: 15 15 256 128 Y EMC
Server, Server SP1 Netwin 200 205E, 207E; CLARiiON
AX150
EMC Connectrix:
3250−VL2E2,
DS−220B−FF−D3,
DS−8B2−0DL;
McDATA ES−43001
14 Microsoft Windows 2003 [x86] Storage: EMC: Integrated, EMC Connectrix: 15 15 256 128 Y EMC
Server, Server SP1 Integrated for Netwin DS−4400M, CLARiiON
200 DS−4700M; AX150
McDATA: ES−4400,
ES−4700
15 Microsoft Windows 2003 [x86] Storage: Emulex LP1050Ex−E; EMC Connectrix: 15 15 256 256 Y EMC
Server, Server SP1 QLogic DS−4400M, CLARiiON
QLE2360−E−SP DS−4700M; AX150
McDATA: ES−4400,
ES−4700
16 Microsoft Windows 2003 [x86] Storage: Emulex: LP1050−E, Brocade Silkworm: 15 15 256 256 Y EMC
Server, Server SP1 LP1050Ex−E, 205E, 207E; CLARiiON
LP1150−E, LP982−E, AX150
LPe111−E, EMC Connectrix:
LPe1150−E; 3250−VL2E2,
DS−220B−FF−D3,
HPQ DS−8B2−0DL;
A8002A/FC2142SR
(LPe1150); McDATA ES−43001;
NEC N8190−127 QLogic SANBox:
(LPe1150); SB1404−10AJ−E,
QLogic: SB3050−08A−E
QLA2340−E−SP,
QLE2360−E−SP
17 Microsoft Windows 2003 [x86]: DataCenter, Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
DataCenter R2, DataCenter SP1, LP982−E; DS−4400M, CLARiiON
Enterprise Edition, Enterprise Edition R2, DS−4700M; AX150
Enterprise Edition SP1, Standard Edition, HPQ A7388A (LP1050);
Standard Edition R2, Standard Edition SP1 QLogic: McDATA: ES−4400,
QLA2310F−E−SP, ES−4700
QLA2340−E−SP;
Unisys
FCH752313−PCX
(LP1050)
18 Microsoft Windows 2003 [x86]: DataCenter, HPQ A7388A (LP1050) EMC Connectrix: 15 15 256 256 Y EMC
DataCenter R2, DataCenter SP1, DS−4400M, CLARiiON
Enterprise Edition, Enterprise Edition R2, DS−4700M; AX150
Enterprise Edition SP1, Standard Edition,
Standard Edition R2, Standard Edition SP1 McDATA: ES−4400,
ES−4700
19 Microsoft Windows 2003 [x86]: DataCenter, NEC N8190−120 EMC Connectrix: 15 15 256 128, 256 Y EMC
DataCenter R2, DataCenter SP1, (LP1050); DS−4400M, CLARiiON
Enterprise Edition, Enterprise Edition R2, QLogic DS−4700M; AX150
Enterprise Edition SP1, Standard Edition, QLE2360−E−SP
Standard Edition R2, Standard Edition SP1 McDATA: ES−4400,
ES−4700
20 Microsoft Windows 2003 [x86]: DataCenter, Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
DataCenter R2, DataCenter SP1, LP1150−E, LP982−E; DS−4400M, CLARiiON
Enterprise Edition, Enterprise Edition R2, DS−4700M; AX150
Enterprise Edition SP1, Standard Edition, IBM 39M5894
Standard Edition R2, Standard Edition SP1, (QLA2460); McDATA: ES−4400,
Storage Server, Storage Server SP1 QLogic: ES−4700
QLA2310F−E−SP,
QLA2340−E−SP,
QLA2460−E−SP,
QLE2460−E−SP,
QLE2462−E−SP
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. This switch is offered by Dell as the Brocade VL2 LC.
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

MiracleLinux MLSE [32−Bit]

11/02/2006 377 CLARiiON AX150


CLARiiON AX150

MiracleLinux MLSE [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 MiracleLinux MLSE [32−Bit] 3.0: GA Emulex Brocade Silkworm: 205E, 15 15 256 128 Y EMC
v2.4.21−9.30AX, GA+ v2.4.21−9.38AX, LP982−E; 207E; CLARiiON
SP1 v2.4.21−20.19AX, SP1+ QLogic AX150
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX QLA2340−E−SP EMC Connectrix:
3250−VL2E3,
DS−220B−FF−D1,
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
2 MiracleLinux MLSE [32−Bit] 3.0: GA Emulex: EMC Connectrix: 15 15 256 223, 256 Y EMC
v2.4.21−9.30AX, GA+ v2.4.21−9.38AX, LP1050−E, DS−4400M, DS−4700M; CLARiiON
SP1 v2.4.21−20.19AX, SP1+ LP982−E; AX150
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX McDATA: ES−4400,
QLogic ES−4700
QLA2340−E−SP
3 MiracleLinux MLSE [32−Bit] 3.0: GA Emulex: EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−9.30AX, GA+ v2.4.21−9.38AX, LP1050−E, DS−4400M, DS−4700M; CLARiiON
SP1 v2.4.21−20.19AX, SP1+ LP982−E; AX150
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX McDATA: ES−4400,
QLogic ES−4700
QLA2340−E−SP
4 MiracleLinux MLSE [32−Bit] 3.0: GA NEC N8190−120 Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
v2.4.21−9.30AX, GA+ v2.4.21−9.38AX, (LP1050) 207E; CLARiiON
SP1 v2.4.21−20.19AX, SP1+ AX150
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX EMC Connectrix:
DS−220B−FF−D1,
DS−4400M, DS−4700M;
McDATA: ES−43002,
ES−4400, ES−4700
5 MiracleLinux MLSE [32−Bit] 3.0: GA Dell 2342M Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
v2.4.21−9.30AX, GA+ v2.4.21−9.38AX, Switch Module (SW3014), CLARiiON
SP1 v2.4.21−20.19AX, SP1+ 4Gb FC Switch Module AX150
v2.4.21−20.29AX, SP2 v2.4.21−37.18AX; (SW4016);
MiracleLinux MLSE [32−Bit] 4.0 GA Dell McDATA FC Switch
v2.6.9−11.19AX Module: (SW4314),
(SW4416);
Dell Optical Pass−thru
Module (J6780)
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

MiracleLinux MLSE [AMD64]

MiracleLinux MLSE [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 MiracleLinux MLSE [AMD64] 3.0 Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
SP2 v2.4.21−37.18AX LP982−E; CLARiiON
QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
2 MiracleLinux MLSE [AMD64] 3.0 Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
SP2 v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
3 MiracleLinux MLSE [AMD64] 3.0 Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
SP2 v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 MiracleLinux MLSE [AMD64] 3.0 NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
SP2 v2.4.21−37.18AX (LP1050) CLARiiON
EMC Connectrix: DS−220B−FF−D ,1 AX150
DS−4400M, DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
5 MiracleLinux MLSE [AMD64]: 3.0 Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
SP2 v2.4.21−37.18AX, 4.0 GA Module (SW3014), 4Gb FC Switch CLARiiON
v2.6.9−11.19AX Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

11/02/2006 378 CLARiiON AX150


CLARiiON AX150

MiracleLinux MLSE [EM64T]

MiracleLinux MLSE [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 MiracleLinux MLSE [EM64T] 3.0 SP2 Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−37.18AX LP982−E; CLARiiON
QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1,
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
2 MiracleLinux MLSE [EM64T] 3.0 SP2 Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
3 MiracleLinux MLSE [EM64T] 3.0 SP2 Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 MiracleLinux MLSE [EM64T] 3.0 SP2 NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
v2.4.21−37.18AX (LP1050) CLARiiON
EMC Connectrix: AX150
DS−220B−FF−D1, DS−4400M,
DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
5 MiracleLinux MLSE [EM64T] 3.0: GA Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
v2.4.21−20.19AX, GA+ Module (SW3014), 4Gb FC CLARiiON
v2.4.21−20.29AX, SP2 Switch Module (SW4016); AX150
v2.4.21−37.18AX;
Dell McDATA FC Switch Module:
MiracleLinux MLSE [EM64T] 4.0 GA (SW4314), (SW4416);
v2.6.9−11.19AX
Dell Optical Pass−thru Module
(J6780)
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Novell Netware

Novell Netware
Operating Luns/Storage Port
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Storage Array
1 Novell Netware QLogic QLA2340−E−SP QLogic SANBox 15 15 256 128 Y EMC CLARiiON AX1501, 2,
6.5 SP3 SB1404−10AJ−E 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13

2 Novell Netware QLogic: QLA200−E−SP, QLogic SANBox 15 15 256 128 Y EMC CLARiiON AX1501, 2,
6.5 SP3 QLA2340−E−SP SB3050−08A−E 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13

3 Novell Netware QLogic: QLA200−E−SP, EMC Connectrix: 15 15 256 128 Y EMC CLARiiON AX1501, 2,
6.5 SP3 QLA2340−E−SP, QLE2360−E−SP 3250−VL2E15, DS−8B2−0DL; 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13

McDATA ES−430014
1. FC−SW environments using Brocade 2800 or EMC DS−16B require switch firmware 2.5.0d or greater.
2. No MirrorView or SnapView used on boot LUNs.
3. To enable failover with fabric boot DOSFAT.NSS must be loaded from the autoexec.ncf. In a failed condition the c:\ partition will not failover
correctly but the DOSFAT_C: partition will.
4. Novell Storage Services supported.
5. For any CLARiiON SP port configured to a host for booting, the maximum number of logical volumes allowed on that port is 32.
6. NetWare boot support is contingent on migration of the DOS boot partition to an NSS partition. NetWare will warn you of the possibility of data corruption if you convert the DOS boot
partition to an NSS partition. The risk of data corruption is during I/O to the C: drive while in the NetWare debugger, or while writing reboot log files during an "Auto Restart After Abend".
When you load DOSFAT, please set "Auto Restart After Abend" to 0 to avoid the possibility of data corruption.
7. Access Logic required, direct connect or fabric, (no booting through switch inter−switch links)
8. Previous versions of the HBA and boot installation guides contained restrictions for boot configurations. All boot configuration information is now listed here and supersedes any found in
previous boot documentation.
9. Requires "SCAN ALL LUNs" in AUTOEXEC.NCF just before the "Mount All" statement.
10. Remote boot not supported with PERC controllers enabled in system BIOS.
11. DOS boot device maximum accessible capacity is 2GB. Netware SYS volume must be in LUN 0.
12. Edit config.sys with the following: Files=100, Buffers=99
13. Supports eight (8) hosts per array.
14. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
15. This switch is offered by Dell as the Brocade VL2 LC.

Oracle Enterprise Linux [32−Bit]

11/02/2006 379 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [32−Bit]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Oracle Enterprise Linux Dell: 2342M, LPe1105−M, Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
[32−Bit] 4 U4 QME2462 Module (SW3014), 4Gb FC CLARiiON
v2.6.9−42.0.0.0.1.EL Switch Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
2 Oracle Enterprise Linux Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
[32−Bit] 4 U4 QLogic QLA2340−E−SP SB1404−10AJ−E CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
3 Oracle Enterprise Linux Emulex: LP101−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
[32−Bit] 4 U4 LP982−E; CLARiiON
v2.6.9−42.0.0.0.1.EL EMC Connectrix: 3250−VL2E2, AX150
QLogic QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox SB3050−08A−E
4 Oracle Enterprise Linux Emulex: LP1050−E, EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
[32−Bit] 4 U4 LP1050Ex−E, LP982−E; DS−4700M; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic QLA2340−E−SP McDATA: ES−4400, ES−4700
5 Oracle Enterprise Linux Emulex: LP1050−E, EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
[32−Bit] 4 U4 LP1150−E, LP982−E, DS−4700M; CLARiiON
v2.6.9−42.0.0.0.1.EL LPe111−E, LPe1150−E; AX150
McDATA: ES−4400, ES−4700
HPQ A8002A/FC2142SR
(LPe1150);
IBM 24P0960 (QLA2340);
QLogic: QLA2340−E−SP,
QLE2460−E−SP
6 Oracle Enterprise Linux IBM 24P0960 (QLA2340); Brocade Silkworm: 205E, 207E; 15 15 256 256 Y EMC
[32−Bit] 4 U4 QLogic QLE2460−E−SP CLARiiON
v2.6.9−42.0.0.0.1.EL EMC Connectrix AX150
DS−220B−FF−D1;
McDATA ES−43003
7 Oracle Enterprise Linux NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
[32−Bit] 4 U4 QLogic QLE2360−E−SP CLARiiON
v2.6.9−42.0.0.0.1.EL EMC Connectrix: AX150
DS−220B−FF−D1, DS−4400M,
DS−4700M;
McDATA: ES−43003, ES−4400,
ES−4700
8 Oracle Enterprise Linux QLogic QLE2360−E−SP EMC Connectrix: 3250−VL2E2, 15 15 256 128, 256 Y EMC
[32−Bit] 4 U4 DS−8B2−0DL; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
9 Oracle Enterprise Linux QLogic QLE2460−E−SP EMC Connectrix: 3250−VL2E2, 15 15 256 256 Y EMC
[32−Bit] 4 U4 DS−8B2−0DL; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

Oracle Enterprise Linux [AMD−64]

Oracle Enterprise Linux [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Oracle Enterprise Linux Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
[AMD−64] 4 U4 QLogic QLA2340−E−SP SB1404−10AJ−E CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
2 Oracle Enterprise Linux Emulex: LP101−E, LP982−E; Brocade Silkworm: 205E, 15 15 256 128 Y EMC
[AMD−64] 4 U4 207E; CLARiiON
v2.6.9−42.0.0.0.1.EL QLogic QLA2340−E−SP AX150
EMC Connectrix:
3250−VL2E1,
DS−220B−FF−D3,
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox
SB3050−08A−E
3 Oracle Enterprise Linux Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
[AMD−64] 4 U4 LP1050Ex−E, LP982−E; DS−4400M, DS−4700M; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic QLA2340−E−SP McDATA: ES−4400,
ES−4700
4 Oracle Enterprise Linux Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
[AMD−64] 4 U4 LP1150−E, LP982−E, DS−4400M, DS−4700M; CLARiiON
v2.6.9−42.0.0.0.1.EL LPe111−E, LPe1150−E; AX150
McDATA: ES−4400,
HPQ A8002A/FC2142SR ES−4700
(LPe1150);
IBM 24P0960 (QLA2340);
QLogic: QLA2340−E−SP,
QLE2460−E−SP

11/02/2006 380 CLARiiON AX150


CLARiiON AX150

Oracle Enterprise Linux [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
5 Oracle Enterprise Linux IBM 24P0960 (QLA2340); Brocade Silkworm: 205E, 15 15 256 256 Y EMC
[AMD−64] 4 U4 QLogic QLE2460−E−SP 207E; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
EMC Connectrix
DS−220B−FF−D3;
McDATA ES−43002
6 Oracle Enterprise Linux NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
[AMD−64] 4 U4 QLogic QLE2360−E−SP 207E; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
EMC Connectrix:
DS−220B−FF−D3,
DS−4400M, DS−4700M;
McDATA: ES−43002,
ES−4400, ES−4700
7 Oracle Enterprise Linux QLogic QLE2360−E−SP EMC Connectrix: 15 15 256 128, 256 Y EMC
[AMD−64] 4 U4 3250−VL2E1, DS−8B2−0DL; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
8 Oracle Enterprise Linux QLogic QLE2460−E−SP EMC Connectrix: 15 15 256 256 Y EMC
[AMD−64] 4 U4 3250−VL2E1, DS−8B2−0DL; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Oracle Enterprise Linux [EM64T]

Oracle Enterprise Linux [EM64T]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Oracle Enterprise Linux Dell: 2342M, LPe1105−M, Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
[EM64T] 4 U4 QME2462 Module (SW3014), 4Gb FC CLARiiON
v2.6.9−42.0.0.0.1.EL Switch Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
2 Oracle Enterprise Linux Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
[EM64T] 4 U4 QLogic QLA2340−E−SP SB1404−10AJ−E CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
3 Oracle Enterprise Linux Emulex: LP101−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
[EM64T] 4 U4 LP982−E; CLARiiON
v2.6.9−42.0.0.0.1.EL EMC Connectrix: 3250−VL2E2, AX150
QLogic QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox SB3050−08A−E
4 Oracle Enterprise Linux Emulex: LP1050−E, EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
[EM64T] 4 U4 LP1050Ex−E, LP982−E; DS−4700M; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic QLA2340−E−SP McDATA: ES−4400, ES−4700
5 Oracle Enterprise Linux Emulex: LP1050−E, EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
[EM64T] 4 U4 LP1150−E, LP982−E, DS−4700M; CLARiiON
v2.6.9−42.0.0.0.1.EL LPe111−E, LPe1150−E; AX150
McDATA: ES−4400, ES−4700
HPQ A8002A/FC2142SR
(LPe1150);
IBM 24P0960 (QLA2340);
QLogic: QLA2340−E−SP,
QLE2460−E−SP
6 Oracle Enterprise Linux IBM 24P0960 (QLA2340); Brocade Silkworm: 205E, 207E; 15 15 256 256 Y EMC
[EM64T] 4 U4 QLogic QLE2460−E−SP CLARiiON
v2.6.9−42.0.0.0.1.EL EMC Connectrix AX150
DS−220B−FF−D1;
McDATA ES−43003
7 Oracle Enterprise Linux NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
[EM64T] 4 U4 QLogic QLE2360−E−SP CLARiiON
v2.6.9−42.0.0.0.1.EL EMC Connectrix: AX150
DS−220B−FF−D1, DS−4400M,
DS−4700M;
McDATA: ES−43003, ES−4400,
ES−4700
8 Oracle Enterprise Linux QLogic QLE2360−E−SP EMC Connectrix: 3250−VL2E2, 15 15 256 128, 256 Y EMC
[EM64T] 4 U4 DS−8B2−0DL; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
9 Oracle Enterprise Linux QLogic QLE2460−E−SP EMC Connectrix: 3250−VL2E2, 15 15 256 256 Y EMC
[EM64T] 4 U4 DS−8B2−0DL; CLARiiON
v2.6.9−42.0.0.0.1.EL AX150
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

11/02/2006 381 CLARiiON AX150


CLARiiON AX150

Red Flag DC Server [32−Bit]

Red Flag DC Server [32−Bit]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Flag DC Server [32−Bit] 4.1: GA Emulex Brocade Silkworm: 205E, 15 15 256 128 Y EMC
2.4.21−9.30AX, GA+ v2.4.21−9.38AX, SP1 LP982−E; 207E; CLARiiON
v2.4.21−20.19AX, SP1+ v2.4.21−20.29AX, QLogic AX150
SP2 v2.4.21−37.18AX QLA2340−E−SP EMC Connectrix:
3250−VL2E3,
DS−220B−FF−D1,
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
2 Red Flag DC Server [32−Bit] 4.1: GA Emulex: EMC Connectrix: 15 15 256 223, 256 Y EMC
2.4.21−9.30AX, GA+ v2.4.21−9.38AX, SP1 LP1050−E, DS−4400M, DS−4700M; CLARiiON
v2.4.21−20.19AX, SP1+ v2.4.21−20.29AX, LP982−E; AX150
SP2 v2.4.21−37.18AX McDATA: ES−4400,
QLogic ES−4700
QLA2340−E−SP
3 Red Flag DC Server [32−Bit] 4.1: GA Emulex: EMC Connectrix: 15 15 256 256 Y EMC
2.4.21−9.30AX, GA+ v2.4.21−9.38AX, SP1 LP1050−E, DS−4400M, DS−4700M; CLARiiON
v2.4.21−20.19AX, SP1+ v2.4.21−20.29AX, LP982−E; AX150
SP2 v2.4.21−37.18AX McDATA: ES−4400,
QLogic ES−4700
QLA2340−E−SP
4 Red Flag DC Server [32−Bit] 4.1: GA NEC N8190−120 Brocade Silkworm: 205E, 15 15 256 128, 256 Y EMC
2.4.21−9.30AX, GA+ v2.4.21−9.38AX, SP1 (LP1050) 207E; CLARiiON
v2.4.21−20.19AX, SP1+ v2.4.21−20.29AX, AX150
SP2 v2.4.21−37.18AX EMC Connectrix:
DS−220B−FF−D1,
DS−4400M, DS−4700M;
McDATA: ES−43002,
ES−4400, ES−4700
5 Red Flag DC Server [32−Bit] 4.1: GA Dell 2342M Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
2.4.21−9.30AX, GA+ v2.4.21−9.38AX, SP1 Switch Module (SW3014), CLARiiON
v2.4.21−20.19AX, SP1+ v2.4.21−20.29AX, 4Gb FC Switch Module AX150
SP2 v2.4.21−37.18AX; (SW4016);
Red Flag DC Server [32−Bit] 5.0 GA Dell McDATA FC Switch
v2.6.9−11.19AX Module: (SW4314),
(SW4416);
Dell Optical Pass−thru
Module (J6780)
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Red Flag DC Server [AMD64]

Red Flag DC Server [AMD64]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Flag DC Server [AMD64] 4.1 Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
SP2 v2.4.21−37.18AX LP982−E; CLARiiON
QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1, DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
2 Red Flag DC Server [AMD64] 4.1 Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
SP2 v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
3 Red Flag DC Server [AMD64] 4.1 Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
SP2 v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 Red Flag DC Server [AMD64] 4.1 NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
SP2 v2.4.21−37.18AX (LP1050) CLARiiON
EMC Connectrix: DS−220B−FF−D1, AX150
DS−4400M, DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
5 Red Flag DC Server [AMD64]: 4.1 Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
SP2 v2.4.21−37.18AX, 5.0 GA Module (SW3014), 4Gb FC Switch CLARiiON
v2.6.9−11.19AX Module (SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module
(J6780)
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

11/02/2006 382 CLARiiON AX150


CLARiiON AX150

Red Flag DC Server [EM64T]

Red Flag DC Server [EM64T]


Host Bus Luns/Storage Port Storage
No. Operating System Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Flag DC Server [EM64T] 4.1 SP2 Emulex Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
v2.4.21−37.18AX LP982−E; CLARiiON
QLogic EMC Connectrix: 3250−VL2E3, AX150
QLA2340−E−SP DS−220B−FF−D1,
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
2 Red Flag DC Server [EM64T] 4.1 SP2 Emulex: EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
3 Red Flag DC Server [EM64T] 4.1 SP2 Emulex: EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
v2.4.21−37.18AX LP1050−E, DS−4700M; CLARiiON
LP982−E; AX150
McDATA: ES−4400, ES−4700
QLogic
QLA2340−E−SP
4 Red Flag DC Server [EM64T] 4.1 SP2 NEC N8190−120 Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
v2.4.21−37.18AX (LP1050) CLARiiON
EMC Connectrix: AX150
DS−220B−FF−D1, DS−4400M,
DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
5 Red Flag DC Server [EM64T] 4.1: GA Dell 2342M Dell Brocade: 1/2Gb FC Switch 15 15 256 256 Y EMC
v2.4.21−20.19AX, GA+ Module (SW3014), 4Gb FC CLARiiON
v2.4.21−20.29AX, SP2 Switch Module (SW4016); AX150
v2.4.21−37.18AX;
Dell McDATA FC Switch Module:
Red Flag DC Server [EM64T] 5.0 GA (SW4314), (SW4416);
v2.6.9−11.19AX
Dell Optical Pass−thru Module
(J6780)
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Red Hat RHEL [32−Bit]

Red Hat RHEL [32−Bit]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [32−Bit] 3.0: U2 AS/ES Dell 2342M Dell Brocade: 15 15 256 256 Y EMC
v2.4.21−15.EL, U2+ AS/ES v2.4.21−15.0.2.EL, U2+ 1/2Gb FC Switch CLARiiON
AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES Module AX150
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 (SW3014), 4Gb
AS/ES v2.4.21−27.EL, U4+ AS/ES FC Switch Module
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, (SW4016);
U4+ AS/ES v2.4.21−27.0.4.EL, U5 AS/ES
v2.4.21−32.EL, U5+ AS/ES v2.4.21−32.0.1.EL, U6 Dell McDATA FC
AS/ES v2.4.21−37.EL, U6+ AS/ES Switch Module:
v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 (SW4314),
AS/ES v2.4.21−47.EL; (SW4416);
Red Hat RHEL [32−Bit] 4.0 AS/ES: v2.6.9−5.0.5.EL, Dell Optical
v2.6.9−5.EL; Pass−thru Module
(J6780)
Red Hat RHEL [32−Bit] 4.0: U1 AS/ES v2.6.9−11.EL,
U2 AS/ES v2.6.9−22.EL, U2+ AS/ES
v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL,
U3+ AS/ES v2.6.9−34.0.2.EL, U4 AS/ES
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL
2 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES Dell: LPe1105−M, Dell Brocade: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QME2462 1/2Gb FC Switch CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; Module AX150
(SW3014), 4Gb
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, FC Switch Module
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES (SW4016);
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Dell McDATA FC
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ Switch Module:
AS/ES v2.6.9−42.0.2.EL (SW4314),
(SW4416);
Dell Optical
Pass−thru Module
(J6780)
3 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLogic SB1404−10AJ−E CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLA2340−E−SP AX150
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL,
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL

11/02/2006 383 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [32−Bit]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
4 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES Emulex: LP101−E, Brocade 15 15 256 128 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP982−E; Silkworm: 205E, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; 207E; AX150
QLogic
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, QLA2340−E−SP EMC Connectrix:
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES 3250−VL2E2,
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ DS−220B−FF−D1,
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES DS−8B2−0DL;
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL McDATA
ES−43003;
QLogic SANBox
SB3050−08A−E
5 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP1050Ex−E, DS−4400M, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; LP982−E; DS−4700M; AX150
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, QLogic McDATA:
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES QLA2340−E−SP ES−4400,
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ ES−4700
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
6 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP1150−E, DS−4400M, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; LP982−E, DS−4700M; AX150
LPe111−E,
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, LPe1150−E; McDATA:
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES ES−4400,
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ HPQ ES−4700
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES A8002A/FC2142SR
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ (LPe1150);
AS/ES v2.6.9−42.0.2.EL IBM 24P0960
(QLA2340);
QLogic:
QLA2340−E−SP,
QLE2460−E−SP
7 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES IBM 24P0960 Brocade 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 (QLA2340); Silkworm: 205E, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLogic 207E; AX150
QLE2460−E−SP
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, EMC Connectrix
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES DS−220B−FF−D1;
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ McDATA
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES ES−43003
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
8 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES NEC N8190−120 Brocade 15 15 256 128, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 (LP1050); Silkworm: 205E, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLogic 207E; AX150
QLE2360−E−SP
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, EMC Connectrix:
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES DS−220B−FF−D1,
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ DS−4400M,
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES DS−4700M;
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL McDATA:
ES−43003,
ES−4400,
ES−4700
9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLE2360−E−SP 3250−VL2E2, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; DS−8B2−0DL; AX150
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, QLogic SANBox:
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES SB1404−10AJ−E,
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ SB3050−08A−E
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
10 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES QLogic EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLE2460−E−SP 3250−VL2E2, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; DS−8B2−0DL; AX150
Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, QLogic SANBox:
U2+ AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES SB1404−10AJ−E,
v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, U3+ SB3050−08A−E
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. This switch is offered by Dell as the Brocade VL2 LC.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

Red Hat RHEL [AMD−64]

Red Hat RHEL [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLogic SB1404−10AJ−E CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLA2340−E−SP AX150
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL,
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL

11/02/2006 384 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
2 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES Emulex: LP101−E, Brocade Silkworm: 15 15 256 128 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP982−E; 205E, 207E; CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; AX150
QLogic EMC Connectrix:
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES QLA2340−E−SP 3250−VL2E1,
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ DS−220B−FF−D3,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, DS−8B2−0DL;
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ McDATA
AS/ES v2.6.9−42.0.2.EL ES−43002;
QLogic SANBox
SB3050−08A−E
3 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP1050Ex−E, DS−4400M, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; LP982−E; DS−4700M; AX150
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES QLogic McDATA:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLA2340−E−SP ES−4400,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, ES−4700
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
4 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP1150−E, DS−4400M, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; LP982−E, DS−4700M; AX150
LPe111−E,
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES LPe1150−E; McDATA:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ ES−4400,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, HPQ ES−4700
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES A8002A/FC2142SR
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ (LPe1150);
AS/ES v2.6.9−42.0.2.EL IBM 24P0960
(QLA2340);
QLogic:
QLA2340−E−SP,
QLE2460−E−SP
5 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES IBM 24P0960 Brocade Silkworm: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 (QLA2340); 205E, 207E; CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLogic AX150
QLE2460−E−SP EMC Connectrix
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES DS−220B−FF−D3;
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ McDATA
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, ES−43002
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
6 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES NEC N8190−120 Brocade Silkworm: 15 15 256 128, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 (LP1050); 205E, 207E; CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLogic AX150
QLE2360−E−SP EMC Connectrix:
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES DS−220B−FF−D3,
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ DS−4400M,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, DS−4700M;
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ McDATA:
AS/ES v2.6.9−42.0.2.EL ES−43002,
ES−4400,
ES−4700
7 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLE2360−E−SP 3250−VL2E1, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; DS−8B2−0DL; AX150
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES QLogic SANBox:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ SB1404−10AJ−E,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, SB3050−08A−E
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
8 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES QLogic EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLE2460−E−SP 3250−VL2E1, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; DS−8B2−0DL; AX150
Red Hat RHEL [AMD−64] 4.0: U2 AS/ES QLogic SANBox:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ SB1404−10AJ−E,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, SB3050−08A−E
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Red Hat RHEL [EM64T]

11/02/2006 385 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Red Hat RHEL [EM64T] 3.0: U2 AS/ES Dell 2342M Dell Brocade: 15 15 256 256 Y EMC
v2.4.21−15.EL, U2+ AS/ES v2.4.21−15.0.2.EL, U2+ 1/2Gb FC Switch CLARiiON
AS/ES v2.4.21−15.0.3.EL, U2+ AS/ES Module AX150
v2.4.21−15.0.4.EL, U3 AS/ES v2.4.21−20.EL, U4 (SW3014), 4Gb
AS/ES v2.4.21−27.EL, U4+ AS/ES FC Switch Module
v2.4.21−27.0.1.EL, U4+ AS/ES v2.4.21−27.0.2.EL, (SW4016);
U4+ AS/ES v2.4.21−27.0.4.EL, U5 AS/ES
v2.4.21−32.EL, U5+ AS/ES v2.4.21−32.0.1.EL, U6 Dell McDATA FC
AS/ES v2.4.21−37.EL, U6+ AS/ES Switch Module:
v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 (SW4314),
AS/ES v2.4.21−47.EL; (SW4416);
Red Hat RHEL [EM64T] 4.0 AS/ES: v2.6.9−5.0.5.EL, Dell Optical
v2.6.9−5.EL; Pass−thru Module
(J6780)
Red Hat RHEL [EM64T] 4.0: U1 AS/ES
v2.6.9−11.EL, U2 AS/ES v2.6.9−22.EL, U2+ AS/ES
v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL,
U3+ AS/ES v2.6.9−34.0.2.EL, U4 AS/ES
v2.6.9−42.EL, U4+ AS/ES v2.6.9−42.0.2.EL
2 Red Hat RHEL [EM64T] 3.0: U6 AS/ES Dell: LPe1105−M, Dell Brocade: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QME2462 1/2Gb FC Switch CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; Module AX150
(SW3014), 4Gb
Red Hat RHEL [EM64T] 4.0: U2 AS/ES FC Switch Module
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ (SW4016);
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL,
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES Dell McDATA FC
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ Switch Module:
AS/ES v2.6.9−42.0.2.EL (SW4314),
(SW4416);
Dell Optical
Pass−thru Module
(J6780)
3 Red Hat RHEL [EM64T] 3.0: U6 AS/ES Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLogic SB1404−10AJ−E CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLA2340−E−SP AX150
Red Hat RHEL [EM64T] 4.0: U2 AS/ES
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL,
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
4 Red Hat RHEL [EM64T] 3.0: U6 AS/ES Emulex: LP101−E, Brocade 15 15 256 128 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP982−E; Silkworm: 205E, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; 207E; AX150
QLogic
Red Hat RHEL [EM64T] 4.0: U2 AS/ES QLA2340−E−SP EMC Connectrix:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ 3250−VL2E2,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, DS−220B−FF−D3,
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES DS−8B2−0DL;
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL McDATA
ES−43001;
QLogic SANBox
SB3050−08A−E
5 Red Hat RHEL [EM64T] 3.0: U6 AS/ES Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP1050Ex−E, DS−4400M, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; LP982−E; DS−4700M; AX150
Red Hat RHEL [EM64T] 4.0: U2 AS/ES QLogic McDATA:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ QLA2340−E−SP ES−4400,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, ES−4700
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
6 Red Hat RHEL [EM64T] 3.0: U6 AS/ES Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 LP1150−E, DS−4400M, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; LP982−E, DS−4700M; AX150
LPe111−E,
Red Hat RHEL [EM64T] 4.0: U2 AS/ES LPe1150−E; McDATA:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ ES−4400,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, HPQ ES−4700
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES A8002A/FC2142SR
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ (LPe1150);
AS/ES v2.6.9−42.0.2.EL IBM 24P0960
(QLA2340);
QLogic:
QLA2340−E−SP,
QLE2460−E−SP
7 Red Hat RHEL [EM64T] 3.0: U6 AS/ES IBM 24P0960 Brocade 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 (QLA2340); Silkworm: 205E, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLogic 207E; AX150
QLE2460−E−SP
Red Hat RHEL [EM64T] 4.0: U2 AS/ES EMC Connectrix
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ DS−220B−FF−D3;
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, McDATA
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES ES−43001
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
8 Red Hat RHEL [EM64T] 3.0: U6 AS/ES NEC N8190−120 Brocade 15 15 256 128, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 (LP1050); Silkworm: 205E, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; QLogic 207E; AX150
QLE2360−E−SP
Red Hat RHEL [EM64T] 4.0: U2 AS/ES EMC Connectrix:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ DS−220B−FF−D3,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, DS−4400M,
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES DS−4700M;
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL McDATA:
ES−43001,
ES−4400,
ES−4700

11/02/2006 386 CLARiiON AX150


CLARiiON AX150

Red Hat RHEL [EM64T]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
9 Red Hat RHEL [EM64T] 3.0: U6 AS/ES QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLE2360−E−SP 3250−VL2E2, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; DS−8B2−0DL; AX150
Red Hat RHEL [EM64T] 4.0: U2 AS/ES QLogic SANBox:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ SB1404−10AJ−E,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, SB3050−08A−E
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
10 Red Hat RHEL [EM64T] 3.0: U6 AS/ES QLogic EMC Connectrix: 15 15 256 256 Y EMC
v2.4.21−37.EL, U6+ AS/ES v2.4.21−37.0.1.EL, U7 QLE2460−E−SP 3250−VL2E2, CLARiiON
AS/ES v2.4.21−40.EL, U8 AS/ES v2.4.21−47.EL; DS−8B2−0DL; AX150
Red Hat RHEL [EM64T] 4.0: U2 AS/ES QLogic SANBox:
v2.6.9−22.EL, U2+ AS/ES v2.6.9−22.0.1.EL, U2+ SB1404−10AJ−E,
AS/ES v2.6.9−22.0.2.EL, U3 AS/ES v2.6.9−34.EL, SB3050−08A−E
U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+
AS/ES v2.6.9−42.0.2.EL
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. This switch is offered by Dell as the Brocade VL2 LC.
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

SuSE SLES [32−Bit]

SuSE SLES [32−Bit]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [32−Bit]: 10, 9 SP1 v2.6.5−7.139, 9 Dell 2342M Dell Brocade: 1/2Gb 15 15 256 256 Y EMC
SP1+ v2.6.5−7.145, 9 SP1+ v2.6.5−7.147, 9 FC Switch Module CLARiiON
SP1+ v2.6.5−7.151, 9 SP2+ v2.6.5−7.201, 9 (SW3014), 4Gb FC AX150
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 Switch Module
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 (SW4016);
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9
SP3+ v2.6.5−7.282 Dell McDATA FC
Switch Module:
(SW4314),
(SW4416)
2 SuSE SLES [32−Bit]: 10, 9 SP1+ v2.6.5−7.151, 9 Dell 2342M Dell Optical 15 15 256 256 Y EMC
SP2+ v2.6.5−7.201, 9 SP2+ v2.6.5−7.202.7, 9 Pass−thru Module CLARiiON
SP3 v2.6.5−7.244, 9 SP3+ v2.6.5−7.252, 9 SP3+ (J6780) AX150
v2.6.5−7.257, 9 SP3+ v2.6.5−7.267, 9 SP3+
v2.6.5−7.276, 9 SP3+ v2.6.5−7.282
3 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 Dell: LPe1105−M, Dell Brocade: 1/2Gb 15 15 256 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 QME2462 FC Switch Module CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 (SW3014), 4Gb FC AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9 Switch Module
SP3+ v2.6.5−7.282 (SW4016);
Dell McDATA FC
Switch Module:
(SW4314),
(SW4416);
Dell Optical
Pass−thru Module
(J6780)
4 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 QLogic SB1404−10AJ−E CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 QLA2340−E−SP AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9
SP3+ v2.6.5−7.282
5 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 Emulex: LP101−E, Brocade Silkworm: 15 15 256 128 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 LP982−E; 205E, 207E; CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9 QLogic EMC Connectrix:
SP3+ v2.6.5−7.282 QLA2340−E−SP 3250−VL2E2,
DS−220B−FF−D3,
DS−8B2−0DL;
McDATA ES−43001;
QLogic SANBox
SB3050−08A−E
6 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 LP1050Ex−E, DS−4400M, CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 LP982−E; DS−4700M; AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9
SP3+ v2.6.5−7.282 QLogic McDATA: ES−4400,
QLA2340−E−SP ES−4700
7 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 LP1150−E, DS−4400M, CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 LP982−E, DS−4700M; AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9 LPe111−E,
SP3+ v2.6.5−7.282 LPe1150−E; McDATA: ES−4400,
ES−4700
HPQ
A8002A/FC2142SR
(LPe1150);
IBM 24P0960
(QLA2340);
QLogic:
QLA2340−E−SP,
QLE2460−E−SP

11/02/2006 387 CLARiiON AX150


CLARiiON AX150

SuSE SLES [32−Bit]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
8 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 IBM 24P0960 Brocade Silkworm: 15 15 256 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 (QLA2340); 205E, 207E; CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 QLogic AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9 QLE2460−E−SP EMC Connectrix
SP3+ v2.6.5−7.282 DS−220B−FF−D3;
McDATA ES−43001
9 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 NEC N8190−120 Brocade Silkworm: 15 15 256 128, 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 (LP1050); 205E, 207E; CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 QLogic AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9 QLE2360−E−SP EMC Connectrix:
SP3+ v2.6.5−7.282 DS−220B−FF−D3,
DS−4400M,
DS−4700M;
McDATA:
ES−43001,
ES−4400, ES−4700
10 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 QLE2360−E−SP 3250−VL2E2, CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 DS−8B2−0DL; AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9
SP3+ v2.6.5−7.282 QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
11 SuSE SLES [32−Bit]: 10, 9 SP2+ v2.6.5−7.201, 9 QLogic EMC Connectrix: 15 15 256 256 Y EMC
SP2+ v2.6.5−7.202.7, 9 SP3 v2.6.5−7.244, 9 QLE2460−E−SP 3250−VL2E2, CLARiiON
SP3+ v2.6.5−7.252, 9 SP3+ v2.6.5−7.257, 9 DS−8B2−0DL; AX150
SP3+ v2.6.5−7.267, 9 SP3+ v2.6.5−7.276, 9
SP3+ v2.6.5−7.282 QLogic SANBox:
SB1404−10AJ−E,
SB3050−08A−E
1. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
2. This switch is offered by Dell as the Brocade VL2 LC.
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

SuSE SLES [AMD−64]

SuSE SLES [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [AMD−64] 9 SP2+: Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; QLogic SB1404−10AJ−E CLARiiON
QLA2340−E−SP AX150
SuSE SLES [AMD−64] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
2 SuSE SLES [AMD−64] 9 SP2+: Emulex: LP101−E, Brocade Silkworm: 15 15 256 128 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; LP982−E; 205E, 207E; CLARiiON
AX150
SuSE SLES [AMD−64] 9: SP3 QLogic EMC Connectrix:
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ QLA2340−E−SP 3250−VL2E1,
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ DS−220B−FF−D2,
v2.6.5−7.276, SP3+ v2.6.5−7.282 DS−8B2−0DL;
McDATA ES−43003;
QLogic SANBox
SB3050−08A−E
3 SuSE SLES [AMD−64] 9 SP2+: Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; LP1050Ex−E, DS−4400M, CLARiiON
LP982−E; DS−4700M; AX150
SuSE SLES [AMD−64] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ QLogic McDATA: ES−4400,
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ QLA2340−E−SP ES−4700
v2.6.5−7.276, SP3+ v2.6.5−7.282
4 SuSE SLES [AMD−64] 9 SP2+: Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; LP1150−E, LP982−E, DS−4400M, CLARiiON
LPe111−E, LPe1150−E; DS−4700M; AX150
SuSE SLES [AMD−64] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ HPQ McDATA: ES−4400,
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ A8002A/FC2142SR ES−4700
v2.6.5−7.276, SP3+ v2.6.5−7.282 (LPe1150);
IBM 24P0960
(QLA2340);
QLogic:
QLA2340−E−SP,
QLE2460−E−SP
5 SuSE SLES [AMD−64] 9 SP2+: IBM 24P0960 Brocade Silkworm: 15 15 256 256 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; (QLA2340); 205E, 207E; CLARiiON
QLogic AX150
SuSE SLES [AMD−64] 9: SP3 QLE2460−E−SP EMC Connectrix
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ DS−220B−FF−D2;
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ McDATA ES−43003
v2.6.5−7.276, SP3+ v2.6.5−7.282
6 SuSE SLES [AMD−64] 9 SP2+: NEC N8190−120 Brocade Silkworm: 15 15 256 128, 256 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; (LP1050); 205E, 207E; CLARiiON
QLogic AX150
SuSE SLES [AMD−64] 9: SP3 QLE2360−E−SP EMC Connectrix:
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ DS−220B−FF−D2,
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ DS−4400M,
v2.6.5−7.276, SP3+ v2.6.5−7.282 DS−4700M;
McDATA: ES−43003,
ES−4400, ES−4700

11/02/2006 388 CLARiiON AX150


CLARiiON AX150

SuSE SLES [AMD−64]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
7 SuSE SLES [AMD−64] 9 SP2+: QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; QLE2360−E−SP 3250−VL2E1, CLARiiON
DS−8B2−0DL; AX150
SuSE SLES [AMD−64] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ QLogic SANBox:
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ SB1404−10AJ−E,
v2.6.5−7.276, SP3+ v2.6.5−7.282 SB3050−08A−E
8 SuSE SLES [AMD−64] 9 SP2+: QLogic EMC Connectrix: 15 15 256 256 Y EMC
v2.6.5−7.201, v2.6.5−7.202.7; QLE2460−E−SP 3250−VL2E1, CLARiiON
DS−8B2−0DL; AX150
SuSE SLES [AMD−64] 9: SP3
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ QLogic SANBox:
v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ SB1404−10AJ−E,
v2.6.5−7.276, SP3+ v2.6.5−7.282 SB3050−08A−E
1. This switch is offered by Dell as the Brocade VL2 LC.
2. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
3. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)

SuSE SLES [EM64T]

SuSE SLES [EM64T]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Dell: LPe1105−M, Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
v2.6.5−7.202.7; QME2462 Switch Module CLARiiON
(SW3014), 4Gb FC AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, Switch Module
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, (SW4016);
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282 Dell McDATA FC
Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru
Module (J6780)
2 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Emulex LP982−E; QLogic SANBox 15 15 256 128 Y EMC
v2.6.5−7.202.7; QLogic SB1404−10AJ−E CLARiiON
QLA2340−E−SP AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244,
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257,
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276,
SP3+ v2.6.5−7.282
3 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Emulex: LP101−E, Brocade Silkworm: 15 15 256 128 Y EMC
v2.6.5−7.202.7; LP982−E; 205E, 207E; CLARiiON
AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, QLogic EMC Connectrix:
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, QLA2340−E−SP 3250−VL2E1,
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, DS−220B−FF−D3,
SP3+ v2.6.5−7.282 DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox
SB3050−08A−E
4 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Emulex: LP1050−E, EMC Connectrix: 15 15 256 223, 256 Y EMC
v2.6.5−7.202.7; LP1050Ex−E, DS−4400M, CLARiiON
LP982−E; DS−4700M; AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244,
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, QLogic McDATA: ES−4400,
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, QLA2340−E−SP ES−4700
SP3+ v2.6.5−7.282
5 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Emulex: LP1050−E, EMC Connectrix: 15 15 256 256 Y EMC
v2.6.5−7.202.7; LP1150−E, DS−4400M, CLARiiON
LP982−E, DS−4700M; AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, LPe111−E,
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, LPe1150−E; McDATA: ES−4400,
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, ES−4700
SP3+ v2.6.5−7.282 HPQ
A8002A/FC2142SR
(LPe1150);
IBM 24P0960
(QLA2340);
QLogic:
QLA2340−E−SP,
QLE2460−E−SP
6 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, IBM 24P0960 Brocade Silkworm: 15 15 256 256 Y EMC
v2.6.5−7.202.7; (QLA2340); 205E, 207E; CLARiiON
QLogic AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, QLE2460−E−SP EMC Connectrix
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, DS−220B−FF−D3;
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, McDATA ES−43002
SP3+ v2.6.5−7.282
7 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, NEC N8190−120 Brocade Silkworm: 15 15 256 128, 256 Y EMC
v2.6.5−7.202.7; (LP1050); 205E, 207E; CLARiiON
QLogic AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, QLE2360−E−SP EMC Connectrix:
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, DS−220B−FF−D3,
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, DS−4400M,
SP3+ v2.6.5−7.282 DS−4700M;
McDATA: ES−43002,
ES−4400, ES−4700

11/02/2006 389 CLARiiON AX150


CLARiiON AX150

SuSE SLES [EM64T]


Luns/Storage Port Storage
No. Operating System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
8 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, QLogic EMC Connectrix: 15 15 256 128, 256 Y EMC
v2.6.5−7.202.7; QLE2360−E−SP 3250−VL2E1, CLARiiON
DS−8B2−0DL; AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244,
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, QLogic SANBox:
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, SB1404−10AJ−E,
SP3+ v2.6.5−7.282 SB3050−08A−E
9 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, QLogic EMC Connectrix: 15 15 256 256 Y EMC
v2.6.5−7.202.7; QLE2460−E−SP 3250−VL2E1, CLARiiON
DS−8B2−0DL; AX150
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244,
SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, QLogic SANBox:
SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, SB1404−10AJ−E,
SP3+ v2.6.5−7.282 SB3050−08A−E
10 SuSE SLES [EM64T] 9: SP1+ v2.6.5−7.151, Dell 2342M Dell Brocade: 1/2Gb FC 15 15 256 256 Y EMC
SP2+ v2.6.5−7.201, SP2+ v2.6.5−7.202.7, Switch Module CLARiiON
SP3 v2.6.5−7.244, SP3+ v2.6.5−7.252, (SW3014), 4Gb FC AX150
SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, Switch Module
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 (SW4016);
Dell McDATA FC
Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru
Module (J6780)
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

SuSE SLES [x86_64]

SuSE SLES [x86_64]


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 SuSE SLES Dell: 2342M, LPe1105−M, Dell Brocade: 1/2Gb FC Switch Module 15 15 256 256 Y EMC
[x86_64] 10 QME2462 (SW3014), 4Gb FC Switch Module CLARiiON
(SW4016); AX150
Dell McDATA FC Switch Module:
(SW4314), (SW4416);
Dell Optical Pass−thru Module (J6780)
2 SuSE SLES Emulex LP982−E; QLogic SANBox SB1404−10AJ−E 15 15 256 128 Y EMC
[x86_64] 10 QLogic QLA2340−E−SP CLARiiON
AX150
3 SuSE SLES Emulex: LP101−E, LP982−E; Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
[x86_64] 10 CLARiiON
QLogic QLA2340−E−SP EMC Connectrix: 3250−VL2E1, AX150
DS−220B−FF−D3, DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox SB3050−08A−E
4 SuSE SLES Emulex: LP1050−E, EMC Connectrix: DS−4400M, 15 15 256 223, 256 Y EMC
[x86_64] 10 LP1050Ex−E, LP982−E; DS−4700M; CLARiiON
AX150
QLogic QLA2340−E−SP McDATA: ES−4400, ES−4700
5 SuSE SLES Emulex: LP1050−E, LP1150−E, EMC Connectrix: DS−4400M, 15 15 256 256 Y EMC
[x86_64] 10 LP982−E, LPe111−E, DS−4700M; CLARiiON
LPe1150−E; AX150
McDATA: ES−4400, ES−4700
HPQ A8002A/FC2142SR
(LPe1150);
IBM 24P0960 (QLA2340);
QLogic: QLA2340−E−SP,
QLE2460−E−SP
6 SuSE SLES IBM 24P0960 (QLA2340); Brocade Silkworm: 205E, 207E; 15 15 256 256 Y EMC
[x86_64] 10 QLogic QLE2460−E−SP CLARiiON
EMC Connectrix DS−220B−FF−D3; AX150
McDATA ES−43002
7 SuSE SLES NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
[x86_64] 10 QLogic QLE2360−E−SP CLARiiON
EMC Connectrix: DS−220B−FF−D3, AX150
DS−4400M, DS−4700M;
McDATA: ES−43002, ES−4400,
ES−4700
8 SuSE SLES QLogic QLE2360−E−SP EMC Connectrix: 3250−VL2E1, 15 15 256 128, 256 Y EMC
[x86_64] 10 DS−8B2−0DL; CLARiiON
AX150
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
9 SuSE SLES QLogic QLE2460−E−SP EMC Connectrix: 3250−VL2E1, 15 15 256 256 Y EMC
[x86_64] 10 DS−8B2−0DL; CLARiiON
AX150
QLogic SANBox: SB1404−10AJ−E,
SB3050−08A−E
1. This switch is offered by Dell as the Brocade VL2 LC.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

Sun Solaris

11/02/2006 390 CLARiiON AX150


CLARiiON AX150

Sun Solaris
Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Sun QLogic QLA2340−E−SP; EMC Connectrix: 3250−VL2E3, 4 15 256 128 Y EMC
Solaris: 10, Sun: SG−XPCI1FC−QL2 DS−220B−FF−D1, DS−4400M, CLARiiON
8, 9 (QLA2340), X6767A DS−4700M, DS−8B2−0DL; AX150
(SG−XPCI1FC−QF2)
McDATA: ES−43002, ES−4400, ES−4700
2 Sun Sun SG−XPCI1FC−EM2 EMC Connectrix: 3250−VL2E3, 4 15 256 128 Y EMC
Solaris: 8, (LP10000) DS−220B−FF−D1, DS−4400M, CLARiiON
9 DS−4700M, DS−8B2−0DL; AX150
McDATA: ES−43002, ES−4400, ES−4700
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

Sun Solaris x86

Sun Solaris x86


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array
1 Sun Solaris Sun EMC Connectrix: 3250−VL2E3, DS−220B−FF−D1, 4 15 256 128 Y EMC
x86 10 SG−XPCI1FC−QL2 DS−4400M, DS−4700M, DS−8B2−0DL; CLARiiON
(QLA2340) AX150
McDATA: ES−43002, ES−4400, ES−4700
1. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.

VMware ESX Server

VMware ESX Server


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array Comments
1 VMware Emulex: LP1050−E, Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC See1
ESX Server: LP1050Ex−E, LP982−E; CLARiiON
v2.5.3, EMC Connectrix: 3250−VL2E3, DS−220B−FF−D4, AX150
v2.5.4 IBM 24P0960 (QLA2340); DS−4400M, DS−4700M, DS−8B2−0DL;
NEC N8190−120 (LP1050);
QLogic QLA2340−E−SP McDATA: ES−43002, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
2 VMware HPQ Dual−port Fibre HPQ Proliant BL p−Class patch panel [FC 15 15 256 256 Y EMC See1
ESX Server: Channel Adapter for HP Pass−through] (306465−B21) CLARiiON
v2.5.3, Proliant BL20p: (G2) AX150
v2.5.4 300874−B21, (G3)
361426−B21;
HPQ Dual−port Fibre
Channel Adapter for HP
Proliant: BL25p/BL45p
381881−B21, BL30p/BL35p
354054−B21
3 VMware IBM HS20 FC Exp Card: IBM Brocade: Enterprise SAN Switch Module For 15 15 256 256 Y EMC See1
ESX Server: (13N2203), (13N2203) for BladeCenter Servers (90P0165), Entry SAN Switch CLARiiON
v2.5.3, IBM eServer LS20, Module For BladeCenter Servers (26K5601); AX150
v2.5.4 (26K4841), (48P7061)
IBM: McData 6−Port Switch Module For BladeCenter
Servers (32R1790), Optical Passthrough Module For
BladeCenter Servers (02R9080), QLogic 2−Port
Switch Module For BladeCenter Servers (48P7062),
QLogic 6−Port Switch Module For BladeCenter
Servers (26K6477)
4 VMware QLogic QLE2360−E−SP Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC See1
ESX Server: CLARiiON
v2.5.3, EMC Connectrix: 3250−VL2E3, DS−220B−FF−D4, AX150
v2.5.4 DS−4400M, DS−4700M, DS−8B2−0DL;
McDATA: ES−43002, ES−4400, ES−4700;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
5 VMware Dell 2342M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 15 15 256 256 Y EMC
ESX Server: 4Gb FC Switch Module (SW4016); CLARiiON
v2.5.3, AX150
v2.5.4, v3.0, Dell McDATA FC Switch Module: (SW4314),
v3.0.1 (SW4416);
Dell Optical Pass−thru Module (J6780)
6 VMware Dell LPe1105−M Dell Brocade: 1/2Gb FC Switch Module (SW3014), 15 15 256 256 Y EMC
ESX Server: 4Gb FC Switch Module (SW4016); CLARiiON
v3.0, v3.0.1 AX150
Dell McDATA FC Switch Module: (SW4314),
(SW4416);
Dell Optical Pass−thru Module (J6780)

11/02/2006 391 CLARiiON AX150


CLARiiON AX150

VMware ESX Server


Operating Luns/Storage Port Storage
No. System Host Bus Adapter Switch Fanin Fanout Port Luns/HBA Sharing Array Comments
7 VMware Emulex LP982−E; Brocade Silkworm: 205E, 207E; 15 15 256 128 Y EMC
ESX Server: QLogic QLA2340−E−SP CLARiiON
v3.0, v3.0.1 EMC Connectrix: 3250−VL2E3, DS−220B−FF−D4, AX150
DS−8B2−0DL;
McDATA ES−43002;
QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E
8 VMware Emulex: LP1050−E, EMC Connectrix: DS−4400M, DS−4700M; 15 15 256 223, 256 Y EMC
ESX Server: LP1050Ex−E, LP982−E; CLARiiON
v3.0, v3.0.1 McDATA: ES−4400, ES−4700 AX150
QLogic QLA2340−E−SP
9 VMware Emulex: LP1050−E, EMC Connectrix: DS−4400M, DS−4700M; 15 15 256 256 Y EMC
ESX Server: LP982−E, LPe1150−E; CLARiiON
v3.0, v3.0.1 McDATA: ES−4400, ES−4700 AX150
HPQ A8002A/FC2142SR
(LPe1150);
IBM 24P0960 (QLA2340);
QLogic: QLA2340−E−SP,
QLE2460−E−SP
10 VMware IBM 24P0960 (QLA2340); Brocade Silkworm: 205E, 207E; 15 15 256 256 Y EMC
ESX Server: QLogic QLE2460−E−SP CLARiiON
v3.0, v3.0.1 EMC Connectrix DS−220B−FF−D4; AX150
McDATA ES−43002
11 VMware NEC N8190−120 (LP1050); Brocade Silkworm: 205E, 207E; 15 15 256 128, 256 Y EMC
ESX Server: QLogic QLE2360−E−SP CLARiiON
v3.0, v3.0.1 EMC Connectrix: DS−220B−FF−D4, DS−4400M, AX150
DS−4700M;
McDATA: ES−43002, ES−4400, ES−4700
12 VMware QLogic QLE2360−E−SP EMC Connectrix: 3250−VL2E3, DS−8B2−0DL; 15 15 256 128, 256 Y EMC
ESX Server: CLARiiON
v3.0, v3.0.1 QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E AX150
13 VMware QLogic QLE2460−E−SP EMC Connectrix: 3250−VL2E3, DS−8B2−0DL; 15 15 256 256 Y EMC
ESX Server: CLARiiON
v3.0, v3.0.1 QLogic SANBox: SB1404−10AJ−E, SB3050−08A−E AX150
1. VMWare ESX does not have dependencies on specific FC−switches and has been found to be broadly interoperable with current generation FC−SW2 compliant Fibre Channel switches.
The listed FC−switches reflect the configurations qualified for support with EMC storage arrays.
2. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
3. This switch is offered by Dell as the Brocade VL2 LC.
4. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.

11/02/2006 392 CLARiiON AX150


Switched Fabric Topology Parameters
Switch Max # ISL
Switch Management Interoperable Domains Max Domain
Firmware Application Switch per # to
No. Switch Revision Revision Interoperable Switch Firmware Fabric Hops Domain Comments Topology
1 Brocade Silkworm v5.0.5, Fabric Manager Brocade Silkworm 205E v5.0.5, v5.1.0a, 1 0 0 See1, 2, 3, 4 FC−SW
205E v5.1.0a, v5.0.0a, Fabric v5.1.0d
v5.1.0d Manager v5.1.0,
Webtools
2 Brocade Silkworm v5.0.5, Fabric Manager Brocade Silkworm 207E v5.0.5, v5.1.0a, 2 1 2 See1, 2, 3, 4 FC−SW
207E v5.1.0a, v5.0.0a, Fabric v5.1.0d
v5.1.0d Manager v5.1.0,
Webtools
3 Brocade Silkworm v3.2.1, Fabric Manager Dell Brocade 1/2Gb FC Switch Module v5.0.5 2 1 2 See1, 2, 3, 4 FC−SW
3800; v3.2.1b v5.0.0a, (SW3014), Dell Brocade 4Gb FC Switch
EMC Connectrix: Webtools Module (SW4016), HPQ Brocade 4/12
DS−16B2, DS−8B2 SAN Switch for HP c−Class Bladesystem
(AE370A)5, HPQ Brocade 4/24 SAN
Switch Power Pack for HP c−Class
Bladesystem (AE371A), HPQ Brocade
4/24 SAN Switch for HP c−Class
Bladesystem (AE372A), HPQ Brocade
4Gb SAN Switch for HP p−Class
BladeSystem, Power Pack (A7535A), IBM
Brocade 10−port 4Gb SAN Switch Module
for BladeCenter Servers (32R1813), IBM
Brocade 20−port 4Gb SAN Switch Module
for BladeCenter Servers (32R1812), IBM
Brocade Enterprise SAN Switch Module
For BladeCenter Servers (90P0165), IBM
Brocade Entry SAN Switch Module For
BladeCenter Servers (26K5601)
4 Brocade Silkworm v5.0.4a, Fabric Manager Brocade Silkworm 4100 v5.0.4a, v5.1.0a 2 1 2 See1, 2, 3, 4 FC−SW
4100 v5.1.0a v5.0.0a,
Webtools
5 Brocade Silkworm: v5.0.5 Fabric Manager Dell Brocade 1/2Gb FC Switch Module v5.0.5 2 1 2 See1, 2, 3, 4 FC−SW
12000, 200E, 24000, v5.0.0a, (SW3014), Dell Brocade 4Gb FC Switch
3250, 3850, 3900, Webtools Module (SW4016), HPQ Brocade 4/12
4100, 48000; SAN Switch for HP c−Class Bladesystem
(AE370A)5, HPQ Brocade 4/24 SAN
EMC Connectrix: Switch Power Pack for HP c−Class
DS−16B3, DS−220B, Bladesystem (AE371A), HPQ Brocade
DS−32B2, DS−4100B, 4/24 SAN Switch for HP c−Class
DS−8B3, ED−12000B, Bladesystem (AE372A), HPQ Brocade
ED−24000B, 4Gb SAN Switch for HP p−Class
ED−48000B BladeSystem, Power Pack (A7535A), IBM
Brocade 10−port 4Gb SAN Switch Module
for BladeCenter Servers (32R1813), IBM
Brocade 20−port 4Gb SAN Switch Module
for BladeCenter Servers (32R1812), IBM
Brocade Enterprise SAN Switch Module
For BladeCenter Servers (90P0165), IBM
Brocade Entry SAN Switch Module For
BladeCenter Servers (26K5601)
6 Brocade Silkworm: v2.6.2b Fabric Manager Dell Brocade 1/2Gb FC Switch Module v5.0.5 2 1 2 See1, 2, 3, 4 FC−SW
2400, 2800; v5.0.0a, (SW3014), Dell Brocade 4Gb FC Switch
Webtools Module (SW4016), HPQ Brocade 4/12
EMC Connectrix: SAN Switch for HP c−Class Bladesystem
DS−16B, DS−8B (AE370A)5, HPQ Brocade 4/24 SAN
Switch Power Pack for HP c−Class
Bladesystem (AE371A), HPQ Brocade
4/24 SAN Switch for HP c−Class
Bladesystem (AE372A), HPQ Brocade
4Gb SAN Switch for HP p−Class
BladeSystem, Power Pack (A7535A), IBM
Brocade 10−port 4Gb SAN Switch Module
for BladeCenter Servers (32R1813), IBM
Brocade 20−port 4Gb SAN Switch Module
for BladeCenter Servers (32R1812), IBM
Brocade Enterprise SAN Switch Module
For BladeCenter Servers (90P0165), IBM
Brocade Entry SAN Switch Module For
BladeCenter Servers (26K5601)

11/02/2006 393 Switched Fabric Topology Parameters


Switched Fabric Topology Parameters

Switch Max # ISL


Switch Management Interoperable Domains Max Domain
Firmware Application Switch per # to
No. Switch Revision Revision Interoperable Switch Firmware Fabric Hops Domain Comments Topology
7 Dell Brocade: 1/2Gb v5.0.5 Fabric Manager Brocade Silkworm 12000, Brocade v5.0.5 2 1 2 See1, 2, 3, 4 FC−SW
FC Switch Module v5.0.0a, Silkworm 200E, Brocade Silkworm 24000,
(SW3014), 4Gb FC Webtools Brocade Silkworm 3250, Brocade
Switch Module Silkworm 3850, Brocade Silkworm 3900,
(SW4016); Brocade Silkworm 4100, Brocade
Silkworm 48000, EMC Connectrix
HPQ Brocade: 4/12 DS−16B3, EMC Connectrix DS−220B,
SAN Switch for HP EMC Connectrix DS−32B2, EMC
c−Class Bladesystem Connectrix DS−4100B, EMC Connectrix
(AE370A)5, 4/24 SAN DS−8B3, EMC Connectrix ED−12000B,
Switch Power Pack for EMC Connectrix ED−24000B, EMC
HP c−Class Connectrix ED−48000B
Bladesystem
(AE371A), 4/24 SAN
Switch for HP c−Class
Bladesystem
(AE372A), 4Gb SAN
Switch for HP p−Class
BladeSystem, Power
Pack (A7535A);
IBM Brocade: 10−port
4Gb SAN Switch
Module for
BladeCenter Servers
(32R1813), 20−port
4Gb SAN Switch
Module for
BladeCenter Servers
(32R1812), Enterprise
SAN Switch Module
For BladeCenter
Servers (90P0165),
Entry SAN Switch
Module For
BladeCenter Servers
(26K5601)
8 Dell Brocade: 1/2Gb v5.0.5 Fabric Manager Brocade Silkworm 2400, Brocade v2.6.2b 2 1 2 See1, 2, 3, 4 FC−SW
FC Switch Module v5.0.0a, Silkworm 2800, EMC Connectrix DS−16B,
(SW3014), 4Gb FC Webtools EMC Connectrix DS−8B
Switch Module
(SW4016);
HPQ Brocade: 4/12
SAN Switch for HP
c−Class Bladesystem
(AE370A)5, 4/24 SAN
Switch Power Pack for
HP c−Class
Bladesystem
(AE371A), 4/24 SAN
Switch for HP c−Class
Bladesystem
(AE372A), 4Gb SAN
Switch for HP p−Class
BladeSystem, Power
Pack (A7535A);
IBM Brocade: 10−port
4Gb SAN Switch
Module for
BladeCenter Servers
(32R1813), 20−port
4Gb SAN Switch
Module for
BladeCenter Servers
(32R1812), Enterprise
SAN Switch Module
For BladeCenter
Servers (90P0165),
Entry SAN Switch
Module For
BladeCenter Servers
(26K5601)

11/02/2006 394 Switched Fabric Topology Parameters


Switched Fabric Topology Parameters

Switch Max # ISL


Switch Management Interoperable Domains Max Domain
Firmware Application Switch per # to
No. Switch Revision Revision Interoperable Switch Firmware Fabric Hops Domain Comments Topology
9 Dell Brocade: 1/2Gb v5.0.5 Fabric Manager Brocade Silkworm 3800, EMC Connectrix v3.2.1, v3.2.1b 2 1 2 See1, 2, 3, 4 FC−SW
FC Switch Module v5.0.0a, DS−16B2, EMC Connectrix DS−8B2
(SW3014), 4Gb FC Webtools
Switch Module
(SW4016);
HPQ Brocade: 4/12
SAN Switch for HP
c−Class Bladesystem
(AE370A)5, 4/24 SAN
Switch Power Pack for
HP c−Class
Bladesystem
(AE371A), 4/24 SAN
Switch for HP c−Class
Bladesystem
(AE372A), 4Gb SAN
Switch for HP p−Class
BladeSystem, Power
Pack (A7535A);
IBM Brocade: 10−port
4Gb SAN Switch
Module for
BladeCenter Servers
(32R1813), 20−port
4Gb SAN Switch
Module for
BladeCenter Servers
(32R1812), Enterprise
SAN Switch Module
For BladeCenter
Servers (90P0165),
Entry SAN Switch
Module For
BladeCenter Servers
(26K5601)
10 Dell McDATA FC 5.2.0.27, EFCM basic EMC Connectrix DS−16M, EMC 6.02.00, 7.01.00, 2 1 2 See1, 2, 3, 4, 8, FC−SW
Switch Module 5.2.0.34 5.02.06, EFCM Connectrix DS−16M2, EMC Connectrix 8.00.00, 8.00.01, 9
(SW4314) basic 5.02.07.2 DS−24M2, EMC Connectrix DS−32M, 8.01.01
EMC Connectrix DS−32M2, EMC
Connectrix ED−140M11, EMC Connectrix
ED−64M12, McDATA ED−606412,
McDATA ED−614011, McDATA ES−3032,
McDATA ES−3216, McDATA ES−3232,
McDATA ES−430010, McDATA ES−4500
11 Dell McDATA FC 5.2.0.27, EFCM basic EMC Connectrix DS−4400M, EMC 8.00.00, 8.00.01, 2 1 2 See1, 2, 3, 4, 8, FC−SW
Switch Module 5.2.0.34 5.02.06, EFCM Connectrix DS−4700M, McDATA 8.01.01 9
(SW4314) basic 5.02.07.2 ES−4400, McDATA ES−4700
12 Dell McDATA FC 5.2.0.27, EFCM basic EMC Connectrix ED−10000M, McDATA 6.02.00, 6.03.01, 2 1 2 See1, 2, 3, 4, 8, FC−SW
Switch Module 5.2.0.34 5.02.06, EFCM Intrepid 100007 6.04.00 9
(SW4314) basic 5.02.07.2
13 Dell McDATA FC 5.2.0.27, EFCM basic McDATA ES−3016 6.01.00, 6.02.00, 2 1 2 See1, 2, 3, 4, 8, FC−SW
Switch Module 5.2.0.34 5.02.06, EFCM 7.01.00, 8.00.00, 9
(SW4314) basic 5.02.07.2 8.00.01
14 EMC Connectrix v5.0.5, Fabric Manager EMC Connectrix 3250−VL2E15 v5.0.5, v5.1.0a, 2 1 2 See1, 2, 3, 4 FC−SW
3250−VL2E15 v5.1.0a, v5.0.0a, Fabric v5.1.0d
v5.1.0d Manager v5.1.0,
Webtools
15 EMC Connectrix v5.0.5, Fabric Manager EMC Connectrix DS−220B−FF−D13 v5.0.5, v5.1.0a, 2 1 2 See1, 2, 3, 4 FC−SW
DS−220B−FF−D13 v5.1.0a, v5.0.0a, Fabric v5.1.0d
v5.1.0d Manager v5.1.0,
Webtools
16 EMC Connectrix v5.0.5, Fabric Manager EMC Connectrix DS−4100B v5.0.5, v5.1.0a, 2 1 2 See1, 2, 3, 4 FC−SW
DS−4100B v5.1.0a, v5.0.0a, Fabric v5.1.0d
v5.1.0d Manager v5.1.0,
Webtools
17 EMC Connectrix v3.2.1, Fabric Manager EMC Connectrix DS−8B2−0DL v3.2.1, v3.2.1b 2 13 2 See1, 2, 3, 4 FC−SW
DS−8B2−0DL v3.2.1b v5.0.0a, Fabric
Manager v5.1.0,
Webtools
18 EMC Connectrix v5.0.5, Fabric Manager EMC Connectrix DS−8B3 v5.0.5, v5.1.0a, 2 13 2 See1, 2, 3, 4 FC−SW
DS−8B3 v5.1.0a, v5.0.0a, Fabric v5.1.0d
v5.1.0d Manager v5.1.0,
Webtools
19 EMC Connectrix 6.02.00, Command Line Dell McDATA FC Switch Module 5.2.0.27, 2 1 2 See1, 2, 3, 4, 8, FC−SW
ED−10000M; 6.03.01, Interface, (SW4314) 5.2.0.34 9
McDATA Intrepid 6.04.00 Connectrix
100007 Manager 8.9.1
20 EMC Connectrix: 6.02.00, Command Line Dell McDATA FC Switch Module 5.2.0.27, 2 1 2 See1, 2, 3, 4, 8, FC−SW
DS−16M, DS−16M2, 7.01.00, Interface, (SW4314) 5.2.0.34 9
DS−24M2, DS−32M, 8.00.00, Connectrix
DS−32M2, 8.00.01, Manager 8.6.1
ED−140M11, 8.01.01
ED−64M12;
McDATA: ED−606412,
ED−614011, ES−3032,
ES−3216, ES−3232,
ES−430010, ES−4500
21 EMC Connectrix: 8.00.00, Command Line Dell McDATA FC Switch Module 5.2.0.27, 2 1 2 See1, 2, 3, 4, 8, FC−SW
DS−4400M, 8.00.01, Interface, (SW4314) 5.2.0.34 9
DS−4700M; 8.01.01 Connectrix
Manager 8.9.1
McDATA: ES−4400,
ES−4700

11/02/2006 395 Switched Fabric Topology Parameters


Switched Fabric Topology Parameters

Switch Max # ISL


Switch Management Interoperable Domains Max Domain
Firmware Application Switch per # to
No. Switch Revision Revision Interoperable Switch Firmware Fabric Hops Domain Comments Topology
22 McDATA ES−3016 6.01.00, Command Line Dell McDATA FC Switch Module 5.2.0.27, 2 1 2 See1, 2, 3, 4, 8, FC−SW
6.02.00, Interface, (SW4314) 5.2.0.34 9
7.01.00, Connectrix
8.00.00, Manager 8.6.1
8.00.01
23 McDATA ES−430010 6.01.0014, Command Line McDATA ES−430010 6.01.0014, 2 1 2 See1, 2, 3, 4 FC−SW
6.02.0014, Interface, EFCM 6.02.0014,
7.01.00 Basic (EWS), 7.01.0014
SAN Pilot
(EWS), SANpilot
(EWS)
24 QLogic SANBox 5.0.1.10.00 SANsurfer QLogic SANBox SB1404−10AJ−E 5.0.1.10.00 2 2 1 See1, 2, 3, 4 FC−SW
SB1404−10AJ−E 5.00.1.05
25 QLogic SANBox 4.0.2.4−0 SANbox QLogic SANBox SB3050−08A−E 4.0.2.4−0 2 1 2 See1, 2, 3, 4 FC−SW
SB3050−08A−E Manager
4.00.11−0714
26 QLogic SANBox 4.0.2.4−0 SANbox QLogic SANBox SB3050−08A−E 4.0.2.4−0 2 1 2 See1, 2, 3, 4, 6 FC−SW
SB3050−08A−E Manager
4.00.11−0714
1. Max # of Domains per Fabric: The maximum number of switches a Fibre Channel fabric may contain under the current topology limitations.
2. Switch Management Application Revision: Switch Management versions are backward compatible. You may manage any lower−level switch with a higher level Management Application
Revision.
3. Max # Hops: The maximum number of ISLs (Inter−Switch Links) a frame needs to traverse between any input port of the fabric to any output port, assuming all ISLs are active (no ISL or
switch fault condition is present). This is the maximum number of hops in a fabric.
4. Switch Management Application Revision: The use of mixed code revisions in the same fabric should be limited to code upgrade processes only. You must always use the management
code rev. associated with the highest level of switch code.
5. HP Part number AE373A is 12 port upgrade license for Brocade 4/12 SAN Switch.
6. the configuration is customer instalable
7. This switch is the same as the IBM SAN256M
8. One of the core fabric switches must be configured to be a principle switch. the blade switches should not acquire the role of principle switch.
9. The following setting should be verified: DefaultZoning = False; DefaultVisibility = None
10. The minimum firmware revision for the ES−4300 is 5.05.00 (This firmware revision is only to be used on ES−4300)
11. Do not attempt to manage an ED−140M containing XPM (10 Gb/sec) or QPM (4 Gb/sec) port modules with Connectrix Manager 7.x. The XPM requires Connectrix Manager 8.7.1 and
the QPM requires Connectrix Manager 8.9.0.
12. Do not attempt to manage an ED−64M containing XPM (10 Gb/sec) port modules with Connectrix Manager 7.x. The XPM requires Connectrix Manager 8.7.1 at a minimum.
13. Dell offers the following versions of the DS−220B−FF−D switch: DS−210B−DE and DS−210B−DEU. Please reference the Dell website for further information.
14. McDATA Open Trunking is supported at E/OS 6.01.00 and above. For configuration information, see the EMC Networked Storage Topology guide.
15. This switch is offered by Dell as the Brocade VL2 LC.

11/02/2006 396 Switched Fabric Topology Parameters


AX100i Rules
Dedicated storage networks are highly recommended, but not required. Hosts can connect to an iSCSI array using a Layer 2 (switched) or Layer 3 (routed) network. Also, the presence of
VPNs on the network should be transparent to the array and are supported as long as the network quality is adequate.

Switches, Routers, Network Interface Cards (NICs), and iSCSI Host Bus Adapters (HBAs)
1. Support is provided for industry standard switches, routers and NICs (Network Interface Cards).
2. Supports up to 4 HBAs or 2 (dual SP) / 1 (single SP) NICs per server connecting to one storage system.
3. A single server can not use HBAs and NICs to connect to the same storage system.
4. Servers can not use a combination of HBAs and NICs to connect to different storage systems.
5. Separate servers, some with HBAs and some with NICs, can connect to the same storage system.
6. A single server cannot use a combination of Fibre Channel HBAs and NICs or iSCSI HBAs to attach to a Fibre storage system and an iSCSI storage system at the same time.
7. A server can be connected to a maximum of 4 CLARiiON storage systems.
8. An initiator can be connected to a maximum of 8 array ports (4 dual SP arrays) or 4 array ports (4 single SP arrays),but no more than 4 storage systems.
9. When a switch or router is present (1Gb), a 10/100 NIC can be used since the connection to the storage system is through the switch or router.

Environments and Configurability


1. The connection to the array must be 1Gb copper (RJ45).
♦ 10/100 NIC connections direct to the array are not supported except to management port(s).
2. Direct Attach is either via 10/100/1000NIC (operating at 1Gb) or via QLA4010C HBA.
3. Initiators per SP port or per storage system:
♦ A maximum of 8 initiators can be connected to a single SP AX100SCi port.
A maximum of 8 hosts can connect to an AX100SCI.
♦ A maximum of 16 initiators can be connected to a dual SP AX100i.
A maximum of 8 hosts can connect to an AX100i.
4. Target array addresses and names must be configured manually in the Initiators.
5. Server names and passwords must be configured manually in the iSCSI storage system.
6. Authentication mechanism to be used is the CHAP protocol (Challenge Handshake Authentication Protocol)
7. A host cannot be connected to both an AX iSCSI storage system and a CX iSCSI storage system.

Considerations
1. The AX100i and AX100SCi has one front end iSCSI port per storage processor.
2. Currently it is not possible to boot a Windows system using an iSCSI disk volume provided by the Microsoft iSCSI Initiator. The only currently supported method for booting a
Windows system using an iSCSI disk volume is via a supported HBA.
3. When using multiple (NICs) in the same server: up to 2 NICs per host are supported to one AX100i array. If multiple NICs are installed, it is recommended that each be on a
different subnet. If multiple NICs are on the same subnet, the MS "Advanced" configuration setup must be utilized in order to take advantage of the additional NICs. If the
"Advanced" configuration setup in the MS initiator is not used, additional NICs would be used typically only in a failover situation.
4. When (HBAs) and NICs can not be present in the same host.
5. When using the Microsoft iSCSI Initiator all NICs in the same host will use the same iSCSI name. The name will identify the host and the NICs will not be identifiable.
6. When using Qlogic iSCSI adapters each HBA will have unique iSCSI names. The name will identify the individual HBA in the host.
7. Dynamic disks are not supported on an iSCSI session using the Microsoft iSCSI initiator.
8. EMC supports up to 2 nodes with iSCSI Windows server 2003 Cluster environments with the with the MS Initiator v 1.05. or later.

11/02/2006 397 AX100i Rules


CLARiiON AX100i
Native iSCSI
Haansoft Asianux Server 2.0 [32−Bit]

Haansoft Asianux Server 2.0 [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Haansoft Asianux Generic NIC 10/10013, Generic NIC GbE13 LAN Only EMC N
Server 2.0 [32−Bit] CLARiiON
GA v2.6.9−11.19AX AX100i
2 Haansoft Asianux Generic NIC 10/10015, Generic NIC GbE15 LAN Only EMC N See11, 14
Server 2.0 [32−Bit] CLARiiON
SP1 v2.6.9−34.21AX AX100i
3 Haansoft Asianux IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 3, 17, 18 , QLogic QLA4050−E−SP1, 2, 3, LAN Only EMC N
Server 2.0 [32−Bit] 4, 5, QLogic QLA4050−E−SP1, 2, 4, 5, 16 , QLogic QLA4050−E−SP1, 2, 4, 5, 6 , QLogic CLARiiON
SP1 v2.6.9−34.21AX QLA4050C−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1, 2, 4, 5, 12 , QLogic QLA4050C−E−SP1, 2, AX100i
4, 5, 6

4 Haansoft Asianux QLogic QLA4010−E−SP1, 2, 3, 8, 9 , QLogic QLA4010C−E−SP2, 7, 8, 9, 10 LAN Only11 EMC N


Server 2.0 [32−Bit] CLARiiON
SP1 v2.6.9−34.21AX AX100i
1. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
2. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
3. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
8. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Firmware Version 3.00.00.16
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
12. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
13. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
14. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
15. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
16. Driver Version 5.00.04 Driver is integrated into the kernel.
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Haansoft Asianux Server 2.0 [AMD64]

Haansoft Asianux Server 2.0 [AMD64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Haansoft Asianux Generic NIC 10/10013, Generic NIC GbE13 LAN Only EMC N
Server 2.0 [AMD64] CLARiiON
GA v2.6.9−11.19AX AX100i
2 Haansoft Asianux Generic NIC 10/10015, Generic NIC GbE15 LAN Only EMC N See11, 14
Server 2.0 [AMD64] CLARiiON
SP1 v2.6.9−34.21AX AX100i
3 Haansoft Asianux IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 4, 17, 18 , QLogic QLA4050−E−SP1, 2, 3, LAN Only EMC N
Server 2.0 [AMD64] 4, 5,
QLogic QLA4050−E−SP2, 3, 4, 5, 16 , QLogic QLA4050−E−SP2, 3, 4, 5, 6 , QLogic CLARiiON
SP1 v2.6.9−34.21AX QLA4050C−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP2, 3, 4, 5, 12 , QLogic QLA4050C−E−SP2, 3, AX100i
4, 5, 6

4 Haansoft Asianux QLogic QLA4010−E−SP1, 4, 5, 7, 8 , QLogic QLA4010C−E−SP5, 7, 8, 9, 10 LAN Only11 EMC N


Server 2.0 [AMD64] CLARiiON
SP1 v2.6.9−34.21AX AX100i
1. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Firmware Version 3.00.00.16
9. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
12. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
13. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
14. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
15. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
16. Driver Version 5.00.04 Driver is integrated into the kernel.
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Haansoft Asianux Server 2.0 [EM64T]

11/02/2006 398 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

Haansoft Asianux Server 2.0 [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Haansoft Asianux Generic NIC 10/10013, Generic NIC GbE13 LAN Only EMC N
Server 2.0 [EM64T] CLARiiON
GA v2.6.9−11.19AX AX100i
2 Haansoft Asianux Generic NIC 10/10014, Generic NIC GbE14 LAN Only EMC N See8, 15
Server 2.0 [EM64T] CLARiiON
SP1 v2.6.9−34.21AX AX100i
3 Haansoft Asianux IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 4, 17, 18 , QLogic QLA4050−E−SP1, 2, 3, LAN Only EMC N
Server 2.0 [EM64T] 4, 5, QLogic QLA4050−E−SP1, 2, 3, 5, 11 , QLogic QLA4050−E−SP1, 2, 3, 5, 16 , QLogic CLARiiON
SP1 v2.6.9−34.21AX QLA4050C−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1, 2, 3, 5, 11 , QLogic QLA4050C−E−SP1, 2, AX100i
3, 5, 12

4 Haansoft Asianux QLogic QLA4010−E−SP1, 2, 4, 7, 10 , QLogic QLA4010C−E−SP2, 6, 7, 9, 10 LAN Only8 EMC N


Server 2.0 [EM64T] CLARiiON
SP1 v2.6.9−34.21AX AX100i
1. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
2. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
3. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
9. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Firmware Version 3.00.00.16
11. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
13. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
14. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
15. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
16. Driver Version 5.00.04 Driver is integrated into the kernel.
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Haansoft Linux 2005 Server Asianux Inside [32−Bit]

Haansoft Linux 2005 Server Asianux Inside [32−Bit]


Host Bus Network Storage External
No. Operating System Adapter Configuration Array Boot
1 Haansoft Linux 2005 Generic NIC LAN Only EMC N
Server Asianux Inside 10/1001, CLARiiON
[32−Bit] v2.4.21−37.18AX Generic NIC AX100i
GbE1
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the
kernel.

Haansoft Linux 2005 Server Asianux Inside [AMD64]

Haansoft Linux 2005 Server Asianux Inside [AMD64]


Host Bus Network Storage External
No. Operating System Adapter Configuration Array Boot
1 Haansoft Linux 2005 Generic NIC LAN Only EMC N
Server Asianux Inside 10/1001, CLARiiON
[AMD64] Generic NIC AX100i
v2.4.21−37.18AX GbE1
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the
kernel.

Haansoft Linux 2005 Server Asianux Inside [EM64T]

Haansoft Linux 2005 Server Asianux Inside [EM64T]


Host Bus Network Storage External
No. Operating System Adapter Configuration Array Boot
1 Haansoft Linux 2005 Generic NIC LAN Only EMC N
Server Asianux Inside 10/1001, CLARiiON
[EM64T] Generic NIC AX100i
v2.4.21−37.18AX GbE1
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the
kernel.

Microsoft Windows 2000

11/02/2006 399 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

Microsoft Windows 2000


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Microsoft Windows Generic NIC 10/1002, 3, 10, 11 , Generic NIC GbE2, 3, 10, 11 LAN Only4 EMC N See5, 6, 7,
2000: Advanced CLARiiON 8, 9
Server SP4, Server AX100i1
SP4
2 Microsoft Windows IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)14, 15, 17, 25, 26, 27 , QLogic LAN Only4, 5 EMC Y20 See6, 8, 9
2000: Advanced QLA4010−E−SP13, 14, 15, 17, 18, 19, 22, 23, 24 , QLogic QLA4010C−E−SP13, 14, 15, 17, 18, 19, 22, 23, 24 , CLARiiON
Server SP4, Server QLogic QLA4050−E−SP 12, 13, 14, 15, 16, 17, 18, 19, 21 , QLogic QLA4050C−E−SP12, 13, 14, 15, 16, 17, AX100i1
SP4 18, 19, 21

1. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
2. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
3. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
4. Routed networks (layer 3) require iSCSI digest to be enabled.
5. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
6. Microsoft Dynamic Disks are not supported.
7. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
8. Powerpath iSCSI 1.1 is not supported with Windows 2000 operating systems.
9. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
10. The following NICs are not supported: 3COM−3C996B
11. Any Microsoft supported server/NIC for the listed operating system revision is supported.
12. BIOS 1.08
13. Driver Version 2.1.3.3
14. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
15. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
16. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
17. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
18. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
19. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
20. Servers booting from external storage with QLA4010 iSCSI boards require Microsoft iSCSI Initiator 2.0 or 2.02 service to be installed. Note that HBA IQN must be altered prior to
Windows installation. Refer to EMC Host Connectivity Guide for information on changing IQN and setting up boot for servers requiring MS iSCSI Initiator service.
21. Firmware Version 2.0.0.38
22. Driver Version 2.1.0.3
23. Firmware Version 3.0.0.16
24. BIOS 1.11
25. Driver Version 2.1.1.0
26. Firmware Version 2.00.00.07
27. BIOS 1.04

Microsoft Windows 2003 [x64]

Microsoft Windows 2003 [x64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Microsoft Windows 2003 [x64] Generic NIC 10/1003, 4, 5, 6, Generic NIC GbE3, 4, 5, 6 LAN Only12 EMC N See7, 8, 9,
Enterprise: Edition, Edition R2; CLARiiON 10, 11
AX100i1
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2;
Microsoft Windows 2003 [x64]
Storage Server: Enterprise Edition
R22, Standard Edition R22
2 Microsoft Windows 2003 [x64] QLogic QLA4010−E−SP14, 15, 18, 19, 20, 23, 24, 25, 26 , QLogic QLA4010C−E−SP14, LAN Only7, 12 EMC N See8, 10, 11
Enterprise: Edition, Edition R2; 15, 18, 19, 20, 23, 24, 25, 26 , QLogic QLA4050−E−SP13, 22, 23 , QLogic CLARiiON
QLA4050C−E−SP13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23 AX100i1
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2;
Microsoft Windows 2003 [x64]
Storage Server: Enterprise Edition
R22, Standard Edition R22
1. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
2. Support for Windows 2003 Storage Server is limited to the connection to EMC storage arrays. Currently, Windows 2003 Storage Server is not supported in target mode for iSCSI
configurations.
3. The following NICs are not supported: 3COM−3C996B
4. Any Microsoft supported server/NIC for the listed operating system revision is supported.
5. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
6. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. Microsoft Dynamic Disks are not supported.
9. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
10. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
11. Powerpath iSCSI 1.1 is supported with Windows 2003 operating systems.
12. Routed networks (layer 3) require iSCSI digest to be enabled.
13. BIOS 1.08
14. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
15. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
16. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
17. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
18. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
19. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
20. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
21. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)
22. Firmware Version 2.0.0.38
23. Driver Version 2.1.3.8

11/02/2006 400 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

24. Firmware Version 3.0.0.16


25. BIOS 1.11
26. Driver Version 2.1.0.8

Microsoft Windows 2003 [x86]

Microsoft Windows 2003 [x86]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Microsoft Windows 2003 Generic NIC 10/10018, 20, 21, 22 , Generic NIC GbE18, 20, 21, 22 LAN Only12 EMC N See8, 9, 10,
[x86] Enterprise: Edition, CLARiiON 11, 19
Edition R2, Edition SP1; AX100i1
Microsoft Windows 2003
[x86] Standard: Edition,
Edition R2, Edition SP1;
Microsoft Windows 2003
[x86] Storage Server
Enterprise Edition: R22,
SP12;
Microsoft Windows 2003
[x86] Storage Server:
Enterprise Edition2, R22,
SP12;
Microsoft Windows 2003
[x86] Storage Server2
2 Microsoft Windows 2003 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 5, 23, 24, 25 , QLogic LAN Only11, 12 EMC Y13 See8, 9, 10
[x86] Enterprise: Edition, QLA4010−E−SP3, 4, 5, 6, 7, 14, 15, 16, 17 , QLogic QLA4010C−E−SP3, 4, 5, 6, 7, 14, 15, 16, 17 , CLARiiON
Edition R2, Edition SP1; QLogic QLA4050−E−SP17, 26, 27, QLogic QLA4050C−E−SP3, 4, 5, 6, 7, 17, 26, 27, 28, 29, 30 AX100i1
Microsoft Windows 2003
[x86] Standard: Edition,
Edition R2, Edition SP1;
Microsoft Windows 2003
[x86] Storage Server
Enterprise Edition: R22,
SP12;
Microsoft Windows 2003
[x86] Storage Server:
Enterprise Edition2, R22,
SP12;
Microsoft Windows 2003
[x86] Storage Server2
1. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
2. Support for Windows 2003 Storage Server is limited to the connection to EMC storage arrays. Currently, Windows 2003 Storage Server is not supported in target mode for iSCSI
configurations.
3. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
4. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
5. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
6. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
7. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
8. Microsoft Dynamic Disks are not supported.
9. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
10. Powerpath iSCSI 1.1 is supported with Windows 2003 operating systems.
11. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
12. Routed networks (layer 3) require iSCSI digest to be enabled.
13. Servers booting from external storage with QLA4010 iSCSI boards require Microsoft iSCSI Initiator 2.0 or 2.02 service to be installed. Note that HBA IQN must be altered prior to
Windows installation. Refer to EMC Host Connectivity Guide for information on changing IQN and setting up boot for servers requiring MS iSCSI Initiator service.
14. Driver Version 2.1.0.8
15. Firmware Version 3.0.0.16
16. BIOS 1.11
17. Driver Version 2.1.3.8
18. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
19. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
20. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
21. The following NICs are not supported: 3COM−3C996B
22. Any Microsoft supported server/NIC for the listed operating system revision is supported.
23. Driver Version 2.1.1.5
24. Firmware Version 2.00.00.07
25. BIOS 1.04
26. BIOS 1.08
27. Firmware Version 2.0.0.38
28. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
29. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
30. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)

MiracleLinux MLSE [32−Bit]

11/02/2006 401 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

MiracleLinux MLSE [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 MiracleLinux MLSE Generic NIC 10/10017, Generic NIC GbE17 LAN Only4 EMC N See5
[32−Bit] 3.0 SP1 CLARiiON
v2.4.21−20.19AX AX100i
2 MiracleLinux MLSE Generic NIC 10/1002, Generic NIC GbE2 LAN Only EMC N
[32−Bit] 3.0 SP2 CLARiiON
v2.4.21−37.18AX AX100i
3 MiracleLinux MLSE Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N
[32−Bit] 4.0 GA CLARiiON
v2.6.9−11.19AX AX100i
4 MiracleLinux MLSE Generic NIC 10/1003, Generic NIC GbE3 LAN Only EMC N See4, 5
[32−Bit] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
5 MiracleLinux MLSE IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, 11, 15, 16 , QLogic QLA4050−E−SP6, 7, 8, 9, LAN Only EMC N
[32−Bit] 4.0 SP1 10,QLogic QLA4050−E−SP7, 8, 9, 10, 11 , QLogic QLA4050−E−SP7, 8, 9, 10, 14 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP7, 8, 9, 10, 11 , QLogic QLA4050C−E−SP7, 8, 9, 10, 14 , QLogic QLA4050C−E−SP7, 8, AX100i
9, 10, 20

6 MiracleLinux MLSE QLogic QLA4010−E−SP9, 10, 11, 12, 13 , QLogic QLA4010C−E−SP10, 12, 13, 18, 19 LAN Only4 EMC N
[32−Bit] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
2. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
3. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
4. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
5. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
6. Driver Version 5.00.04 Driver is integrated into the kernel.
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 3.00.00.16
14. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
18. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.

MiracleLinux MLSE [AMD64]

MiracleLinux MLSE [AMD64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 MiracleLinux MLSE Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N
[AMD64] 3.0 SP2 CLARiiON
v2.4.21−37.18AX AX100i
2 MiracleLinux MLSE Generic NIC 10/1002, Generic NIC GbE2 LAN Only EMC N
[AMD64] 4.0 GA CLARiiON
v2.6.9−11.19AX AX100i
3 MiracleLinux MLSE Generic NIC 10/1005, Generic NIC GbE5 LAN Only EMC N See3, 4
[AMD64] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
4 MiracleLinux MLSE IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, 11, 15, 16 , QLogic QLA4050−E−SP6, 7, 8, LAN Only EMC N
[AMD64] 4.0 SP1 9, 10,
QLogic QLA4050−E−SP6, 7, 9, 10, 11 , QLogic QLA4050−E−SP6, 7, 9, 10, 12 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP6, 7, 9, 10, 11 , QLogic QLA4050C−E−SP6, 7, 9, 10, 12 , QLogic QLA4050C−E−SP6, 7, AX100i
9, 10, 19

5 MiracleLinux MLSE QLogic QLA4010−E−SP9, 10, 11, 13, 14 , QLogic QLA4010C−E−SP10, 13, 14, 17, 18 LAN Only3 EMC N
[AMD64] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
2. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
5. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
6. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Driver Version 5.00.04 Driver is integrated into the kernel.
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.

MiracleLinux MLSE [EM64T]

11/02/2006 402 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

MiracleLinux MLSE [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 MiracleLinux MLSE Generic NIC 10/10010, Generic NIC GbE10 LAN Only2 EMC N See3
[EM64T] 3.0 GA CLARiiON
v2.4.21−20.19AX AX100i
2 MiracleLinux MLSE Generic NIC 10/10019, Generic NIC GbE19 LAN Only EMC N
[EM64T] 3.0 SP2 CLARiiON
v2.4.21−37.18AX AX100i
3 MiracleLinux MLSE Generic NIC 10/1004, Generic NIC GbE4 LAN Only EMC N
[EM64T] 4.0 GA CLARiiON
v2.6.9−11.19AX AX100i
4 MiracleLinux MLSE Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N See2, 3
[EM64T] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
5 MiracleLinux MLSE IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, 11, 15, 16 , QLogic QLA4050−E−SP5, 6, 7, LAN Only EMC N
[EM64T] 4.0 SP1 8, 9, QLogic QLA4050−E−SP6, 7, 8, 9, 11 , QLogic QLA4050−E−SP6, 7, 8, 9, 12 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP6, 7, 8, 9, 11 , QLogic QLA4050C−E−SP6, 7, 8, 9, 12 , QLogic QLA4050C−E−SP6, 7, AX100i
8, 9, 20

6 MiracleLinux MLSE QLogic QLA4010−E−SP8, 9, 11, 13, 14 , QLogic QLA4010C−E−SP9, 13, 14, 17, 18 LAN Only2 EMC N
[EM64T] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
5. Driver Version 5.00.04 Driver is integrated into the kernel.
6. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
10. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 3.00.00.16
14. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.

Oracle Enterprise Linux [32−Bit]

Oracle Enterprise Linux [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Oracle Enterprise Linux [32−Bit] 4 Generic NIC 10/10011, Generic NIC GbE11 LAN Only EMC N See6, 10
U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX100i
2 Oracle Enterprise Linux [32−Bit] 4 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 4, 12, 13, 14 , QLogic LAN Only EMC N
U4 v2.6.9−42.0.0.0.1.EL QLA4050−E−SP1, 4, 5, 7, 8 , QLogic QLA4050C−E−SP1, 4, 5, 7, 8 CLARiiON
AX100i
3 Oracle Enterprise Linux [32−Bit] 4 QLogic QLA4010−E−SP1, 2, 3, 4, 5 , QLogic QLA4010C−E−SP1, 2, 3, 5, 9 LAN Only6 EMC N
U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX100i
1. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 3.00.00.16
3. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
11. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
12. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 2.00.00.38

Oracle Enterprise Linux [AMD−64]

Oracle Enterprise Linux [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Oracle Enterprise Linux [AMD−64] Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N See2, 3
4 U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX100i

11/02/2006 403 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

Oracle Enterprise Linux [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
2 Oracle Enterprise Linux [AMD−64] IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 5, 13, 14, 15 , QLogic LAN Only EMC N
4 U4 v2.6.9−42.0.0.0.1.EL QLA4050−E−SP4, 5, 6, 7, 8 , QLogic QLA4050C−E−SP4, 5, 6, 7, 8 CLARiiON
AX100i
3 Oracle Enterprise Linux [AMD−64] QLogic QLA4010−E−SP4, 5, 6, 9, 10 , QLogic QLA4010C−E−SP6, 9, 10, 11, 12 LAN Only2 EMC N
4 U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX100i
1. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Firmware Version 3.00.00.16
10. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.07
12. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Firmware Version 2.00.00.38
14. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Oracle Enterprise Linux [EM64T]

Oracle Enterprise Linux [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Oracle Enterprise Linux [EM64T] Generic NIC 10/10014, Generic NIC GbE14 LAN Only EMC N See8, 13
4 U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX100i
2 Oracle Enterprise Linux [EM64T] IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 4, 10, 11, 12 , QLogic LAN Only EMC N
4 U4 v2.6.9−42.0.0.0.1.EL QLA4050−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX100i
3 Oracle Enterprise Linux [EM64T] QLogic QLA4010−E−SP1, 4, 5, 6, 7 , QLogic QLA4010C−E−SP1, 5, 6, 7, 9 LAN Only8 EMC N
4 U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX100i
1. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Firmware Version 3.00.00.16
8. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
9. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Firmware Version 2.00.00.38
12. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
14. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.

Red Flag DC Server [32−Bit]

Red Flag DC Server [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Flag DC Server Generic NIC 10/10016, Generic NIC GbE16 LAN Only3 EMC N See13
[32−Bit] 4.1 SP1 CLARiiON
v2.4.21−20.19AX AX100i
2 Red Flag DC Server Generic NIC 10/10014, Generic NIC GbE14 LAN Only EMC N
[32−Bit] 4.1 SP2 CLARiiON
v2.4.21−37.18AX AX100i
3 Red Flag DC Server Generic NIC 10/10020, Generic NIC GbE20 LAN Only EMC N
[32−Bit] 5.0 GA CLARiiON
v2.6.9−11.19AX AX100i
4 Red Flag DC Server Generic NIC 10/10012, Generic NIC GbE12 LAN Only EMC N See3, 13
[32−Bit] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
5 Red Flag DC Server IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)7, 17, 18, 19 , QLogic QLA4050−E−SP1, 7, 8, LAN Only EMC N
[32−Bit] 5.0 SP1 9, 10, QLogic QLA4050−E−SP1, 7, 9, 10, 15 , QLogic QLA4050−E−SP1, 7, 9, 10, 17 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP1, 7, 8, 9, 10 , QLogic QLA4050C−E−SP1, 7, 9, 10, 11 , QLogic QLA4050C−E−SP1, 7, AX100i
9, 10, 17

6 Red Flag DC Server QLogic QLA4010−E−SP1, 4, 5, 7, 17 , QLogic QLA4010C−E−SP1, 2, 4, 5, 6 LAN Only3 EMC N
[32−Bit] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i

11/02/2006 404 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

1. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
2. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Firmware Version 3.00.00.16
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
8. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
13. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
14. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.

Red Flag DC Server [AMD64]

Red Flag DC Server [AMD64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Flag DC Server Generic NIC 10/10014, Generic NIC GbE14 LAN Only EMC N
[AMD64] 4.1 SP2 CLARiiON
v2.4.21−37.18AX AX100i
2 Red Flag DC Server Generic NIC 10/10019, Generic NIC GbE19 LAN Only EMC N
[AMD64] 5.0 GA CLARiiON
v2.6.9−11.19AX AX100i
3 Red Flag DC Server Generic NIC 10/10013, Generic NIC GbE13 LAN Only EMC N See6, 12
[AMD64] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
4 Red Flag DC Server IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 16, 17, 18 , QLogic QLA4050−E−SP1, 2, 3, LAN Only EMC N
[AMD64] 5.0 SP1 4, 5,
QLogic QLA4050−E−SP2, 3, 4, 5, 15 , QLogic QLA4050−E−SP2, 3, 4, 5, 16 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP2, 3, 4, 5, 11 , QLogic QLA4050C−E−SP2, 3, 4, AX100i
5, 16

5 Red Flag DC Server QLogic QLA4010−E−SP4, 5, 8, 9, 16 , QLogic QLA4010C−E−SP5, 7, 8, 9, 10 LAN Only6 EMC N
[AMD64] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
8. Firmware Version 3.00.00.16
9. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
13. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
14. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.

Red Flag DC Server [EM64T]

Red Flag DC Server [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Flag DC Server Generic NIC 10/10010, Generic NIC GbE10 LAN Only8 EMC N See9
[EM64T] 4.1 GA CLARiiON
v2.4.21−20.19AX AX100i
2 Red Flag DC Server Generic NIC 10/10011, Generic NIC GbE11 LAN Only EMC N
[EM64T] 4.1 SP2 CLARiiON
v2.4.21−37.18AX AX100i
3 Red Flag DC Server Generic NIC 10/1006, Generic NIC GbE6 LAN Only EMC N
[EM64T] 5.0 GA CLARiiON
v2.6.9−11.19AX AX100i
4 Red Flag DC Server Generic NIC 10/1007, Generic NIC GbE7 LAN Only EMC N See8, 9
[EM64T] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
5 Red Flag DC Server IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 13, 17, 18 , QLogic QLA4050−E−SP1, 2, 4, LAN Only EMC N
[EM64T] 5.0 SP1 5, 12, QLogic QLA4050−E−SP1, 2, 4, 5, 13 , QLogic QLA4050−E−SP1, 2, 4, 5, 16 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1, 2, 4, 5, 13 , QLogic QLA4050C−E−SP1, 2, 4, AX100i
5, 16

11/02/2006 405 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

Red Flag DC Server [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
6 Red Flag DC Server QLogic QLA4010−E−SP4, 5, 13, 14, 15 , QLogic QLA4010C−E−SP5, 14, 15, 19, 20 LAN Only8 EMC N
[EM64T] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX100i
1. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
7. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
8. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
9. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
10. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
11. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
12. Driver Version 5.00.04 Driver is integrated into the kernel.
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Red Hat RHEL [32−Bit]

Red Hat RHEL [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP3, 15, 18, 27 , QLogic LAN Only EMC N
QLA4010C−E−SP15, 18, 27 CLARiiON
AX100i
2 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP3, 15, 18, 27 , QLogic LAN Only EMC N See7, 8
QLA4010C−E−SP15, 18, 27 CLARiiON
AX100i
3 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES v2.4.21−47.EL IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
(26K6487)3, 12, 19, 24 , QLogic QLA4010−E−SP3, 15, 18, CLARiiON
24,QLogic QLA4010C−E−SP15, 18, 24, QLogic AX100i
QLA4050−E−SP2, 3, 4, 5, 24 , QLogic QLA4050C−E−SP2,
3, 4, 5, 24

4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP3, 15, 18, 24 , QLogic LAN Only EMC N See7, 8
QLA4010C−E−SP15, 18, 24 CLARiiON
AX100i
5 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10023, Generic NIC GbE22, 23 LAN Only EMC N See7, 8
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX100i
6 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP3, 4, 15, 18, 21 , QLogic LAN Only7 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP4, 15, 17, 18, 20 CLARiiON
AX100i
7 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)1, 3, 12, 25 CLARiiON
AX100i
8 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP1, 2, 3, 4, 5 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX100i
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10026, Generic NIC GbE26 LAN Only EMC N See7, 8
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX100i
10 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)3, 10, 11, 12 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 11, QLogic QLA4050C−E−SP2, 3, 4, 5, 11 AX100i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP3, 4, 11, 15, 18 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP4, 15, 16, 17, 18 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/1009, Generic NIC GbE9 LAN Only EMC N See7, 8
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP2, 3, 4, 5, 14 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP2, 3, 4, 5, 13 CLARiiON
AX100i
14 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)3, 6, 10, 12, 19 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
6,QLogic QLA4050C−E−SP2, 3, 4, 5, 6 AX100i
15 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP3, 4, 6, 15, 18 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP4, 6, 15, 17, 18 CLARiiON
AX100i

11/02/2006 406 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

1. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
4. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
10. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
14. Driver Version 5.00.04 Driver is integrated into the kernel.
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Firmware Version 3.00.00.16
19. Firmware Version 2.00.00.38
20. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
21. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. The following NICs are not supported: 3COM−3C996B
23. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
24. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
26. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
27. Driver Version 3.22

Red Hat RHEL [AMD−64]

Red Hat RHEL [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Hat RHEL [AMD−64] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 7, 9, 24, QLogic LAN Only EMC N
QLA4010C−E−SP7, 9, 24 CLARiiON
AX100i
2 Red Hat RHEL [AMD−64] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 7, 9, 24, QLogic LAN Only EMC N See6, 13
QLA4010C−E−SP7, 9, 24 CLARiiON
AX100i
3 Red Hat RHEL [AMD−64] 3.0 U8 AS/ES v2.4.21−47.EL IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
(26K6487)4, 18, 22, 26 , QLogic QLA4010−E−SP4, 7, 9, 22, CLARiiON
QLogic QLA4010C−E−SP7, 9, 22, QLogic AX100i
QLA4050−E−SP1, 2, 4, 5, 22 , QLogic
QLA4050C−E−SP1, 2, 4, 5, 22
4 Red Hat RHEL [AMD−64] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP4, 7, 9, 22, QLogic LAN Only EMC N See6, 13
QLA4010C−E−SP7, 9, 22 CLARiiON
AX100i
5 Red Hat RHEL [AMD−64] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10016, Generic NIC GbE15, 16 LAN Only EMC N See6, 13
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX100i
6 Red Hat RHEL [AMD−64] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 7, 9, 12 , QLogic LAN Only6 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 7, 8, 9, 10 CLARiiON
AX100i
7 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)4, 11, 18, 21 CLARiiON
AX100i
8 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP1, 2, 4, 5, 11 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP1, 2, 4, 5, 11 CLARiiON
AX100i
Red Hat RHEL [AMD−64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10023, Generic NIC GbE23 LAN Only EMC N See6, 13
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX100i
10 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)3, 4, 18, 19 , QLogic QLA4050−E−SP1, 2, 3, 4, 5 , CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA4050C−E−SP1, 2, 3, 4, 5 AX100i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP3, 4, 5, 7, 9 , QLogic LAN Only6 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 7, 9, 10, 17 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10014, Generic NIC GbE14 LAN Only EMC N See6, 13
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [AMD−64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP1, 2, 4, 5, 28 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP1, 2, 4, 5, 27 CLARiiON
AX100i
14 Red Hat RHEL [AMD−64] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 18, 19, 20, 26 , QLogic QLA4050−E−SP1, 2, 4, CLARiiON
5, 20,
QLogic QLA4050C−E−SP1, 2, 4, 5, 20 AX100i
15 Red Hat RHEL [AMD−64] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 7, 9, 20 , QLogic LAN Only6 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 7, 9, 10, 25 CLARiiON
AX100i

11/02/2006 407 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

1. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. Firmware Version 3.00.00.16
8. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
14. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
15. The following NICs are not supported: 3COM−3C996B
16. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
24. Driver Version 3.22
25. Driver Version 5.00.07
26. Firmware Version 2.00.00.38
27. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
28. Driver Version 5.00.04 Driver is integrated into the kernel.

Red Hat RHEL [EM64T]

Red Hat RHEL [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 13, 15, 25 , QLogic LAN Only EMC N
QLA4010C−E−SP13, 15, 25 CLARiiON
AX100i
2 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 13, 15, 25 , QLogic LAN Only EMC N See10, 11
QLA4010C−E−SP13, 15, 25 CLARiiON
AX100i
3 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
(26K6487)1, 4, 8, 19, QLogic QLA4010−E−SP1, 4, 13, 15 , CLARiiON
QLogic QLA4010C−E−SP1, 13, 15, QLogic AX100i
QLA4050−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1,
2, 3, 4, 5

4 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP1, 4, 13, 15 , QLogic LAN Only EMC N See10, 11
QLA4010C−E−SP1, 13, 15 CLARiiON
AX100i
5 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10020, Generic NIC GbE20, 21 LAN Only EMC N See10, 11
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX100i
6 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 13, 15, 18 , QLogic LAN Only10 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 13, 14, 15, 16 CLARiiON
AX100i
7 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)4, 8, 22, 23 CLARiiON
AX100i
8 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP2, 3, 4, 5, 22 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP2, 3, 4, 5, 22 CLARiiON
AX100i
Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10024, Generic NIC GbE24 LAN Only EMC N See10, 11
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX100i
10 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)4, 6, 7, 8, QLogic QLA4050−E−SP2, 3, 4, 5, 7 , CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA4050C−E−SP2, 3, 4, 5, 7 AX100i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP4, 5, 7, 13, 15 , QLogic LAN Only10 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 13, 15, 16, 17 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10012, Generic NIC GbE12 LAN Only EMC N See10, 11
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX100i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP2, 3, 4, 5, 27 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP2, 3, 4, 5, 26 CLARiiON
AX100i
14 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 6, 8, 9, 19 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
9,QLogic QLA4050C−E−SP2, 3, 4, 5, 9 AX100i
15 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 9, 13, 15 , QLogic LAN Only10 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 9, 13, 15, 16 CLARiiON
AX100i

11/02/2006 408 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

1. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
11. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
12. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
13. Firmware Version 3.00.00.16
14. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Firmware Version 2.00.00.38
20. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
21. The following NICs are not supported: 3COM−3C996B
22. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
24. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
25. Driver Version 3.22
26. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
27. Driver Version 5.00.04 Driver is integrated into the kernel.

SuSE SLES [32−Bit]

SuSE SLES [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [32−Bit] 10 Generic NIC 10/10022, Generic NIC GbE5, 21 LAN Only EMC N See1, 2
CLARiiON
AX100i
2 SuSE SLES [32−Bit] 10 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, LAN Only EMC N
17, 18, 19 CLARiiON
AX100i
3 SuSE SLES [32−Bit] 8 SP4+: v2.4.21−281, v2.4.21−286, Generic NIC 10/1003, Generic NIC GbE3, 4 LAN Only EMC N See1, 2
v2.4.21−295, v2.4.21−304, v2.4.21−306, v2.4.21−309 CLARiiON
AX100i
4 SuSE SLES [32−Bit] 8: SP4 v2.4.21−278, SP4+ QLogic QLA4010−E−SP6, 7, 8, 9, 10 , QLogic LAN Only1 EMC N
v2.4.21−281, SP4+ v2.4.21−286, SP4+ v2.4.21−295, SP4+ QLA4010C−E−SP6, 7, 10, 11, 12 CLARiiON
v2.4.21−304, SP4+ v2.4.21−306, SP4+ v2.4.21−309 AX100i
5 SuSE SLES [32−Bit] 9 SP2+: v2.6.5−7.201, v2.6.5−7.202.7 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, LAN Only EMC N
19, 20, 23 , QLogic QLA4050−E−SP9, 10, 13, 15, 20 , QLogic CLARiiON
QLA4050C−E−SP9, 10, 13, 15, 20 AX100i
6 SuSE SLES [32−Bit] 9 SP2+: v2.6.5−7.201, v2.6.5−7.202.7 QLogic QLA4010−E−SP6, 7, 9, 10, 20 , QLogic LAN Only1 EMC N
QLA4010C−E−SP6, 7, 10, 11, 24 CLARiiON
AX100i
7 SuSE SLES [32−Bit] 9 SP2+: v2.6.5−7.201, v2.6.5−7.202.7; Generic NIC 10/1005, Generic NIC GbE5 LAN Only EMC N See1, 2
CLARiiON
SuSE SLES [32−Bit] 9: SP3 v2.6.5−7.244, SP3+ AX100i
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267,
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282
8 SuSE SLES [32−Bit] 9: SP3 v2.6.5−7.244, SP3+ IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, LAN Only EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, 16, 17, 19 , QLogic QLA4050−E−SP9, 10, 13, 15, 16 , QLogic CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLA4050C−E−SP9, 10, 13, 14, 15 AX100i
9 SuSE SLES [32−Bit] 9: SP3 v2.6.5−7.244, SP3+ QLogic QLA4010−E−SP6, 7, 9, 10, 16 , QLogic LAN Only1 EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, QLA4010C−E−SP6, 7, 9, 10, 16 CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 AX100i
1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
4. The following NICs are not supported: 3COM−3C996B
5. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
6. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Firmware Version 3.00.00.16
8. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
15. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Driver is integrated into the kernel.
17. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version 5.00.04−d5 Driver is integrated into the kernel.
19. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Driver Version iSCSI Software Initiator 1.0−595 Driver is integrated into the kernel.
22. Driver Version iSCSI Software Initiator 1.0−595 DS−M Connect ONLY interoperates with ControlCenter Host Agent, Symmetrix SDM Agent, Storage Agent for Symmetrix.
23. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
24. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com

11/02/2006 409 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

SuSE SLES [AMD−64]

SuSE SLES [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [AMD−64] 8: SP4 v2.4.21−278, SP4+ Generic NIC 10/1001, Generic NIC GbE1, 4 LAN Only EMC N See2, 3
v2.4.21−281, SP4+ v2.4.21−286, SP4+ v2.4.21−295 CLARiiON
AX100i
2 SuSE SLES [AMD−64] 8: SP4 v2.4.21−278, SP4+ QLogic QLA4010−E−SP7, 8, 9, 10, 20 , QLogic LAN Only2 EMC N
v2.4.21−281, SP4+ v2.4.21−286, SP4+ v2.4.21−295 QLA4010C−E−SP7, 8, 10, 18, 19 CLARiiON
AX100i
3 SuSE SLES [AMD−64] 9 SP2+: v2.6.5−7.201, IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, 12, LAN Only EMC N
v2.6.5−7.202.7 15, 16, QLogic QLA4050−E−SP9, 10, 11, 12, 13 , QLogic CLARiiON
QLA4050C−E−SP9, 10, 11, 12, 13 AX100i
4 SuSE SLES [AMD−64] 9 SP2+: v2.6.5−7.201, QLogic QLA4010−E−SP7, 8, 9, 10, 12 , QLogic LAN Only2 EMC N
v2.6.5−7.202.7 QLA4010C−E−SP7, 8, 10, 17, 18 CLARiiON
AX100i
5 SuSE SLES [AMD−64] 9 SP2+: v2.6.5−7.201, Generic NIC 10/1005, Generic NIC GbE5 LAN Only EMC N See2, 3
v2.6.5−7.202.7; CLARiiON
AX100i
SuSE SLES [AMD−64] 9: SP3 v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267,
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282
6 SuSE SLES [AMD−64] 9: SP3 v2.6.5−7.244, SP3+ IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)6, 9, LAN Only EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, 14, 15, QLogic QLA4050−E−SP6, 9, 10, 11, 13 , QLogic CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLA4050C−E−SP9, 10, 11, 13, 21 AX100i
7 SuSE SLES [AMD−64] 9: SP3 v2.6.5−7.244, SP3+ QLogic QLA4010−E−SP6, 7, 8, 9, 10 , QLogic LAN Only2 EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, QLA4010C−E−SP6, 7, 8, 9, 10 CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 AX100i
1. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. The following NICs are not supported: 3COM−3C996B
5. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
6. Driver Version 5.00.04 Driver is integrated into the kernel.
7. Firmware Version 3.00.00.16
8. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.

SuSE SLES [EM64T]

SuSE SLES [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 5, 6, LAN Only EMC N
v2.6.5−7.202.7 7, QLogic QLA4050−E−SP4, 7, 11, 15, 16 , QLogic CLARiiON
QLA4050C−E−SP4, 7, 11, 15, 16 AX100i
2 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, QLogic QLA4010−E−SP4, 7, 8, 10, 11 , QLogic LAN Only2 EMC N
v2.6.5−7.202.7 QLA4010C−E−SP8, 9, 10, 11, 12 CLARiiON
AX100i
3 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N See2, 3
v2.6.5−7.202.7; CLARiiON
AX100i
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267,
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282
4 SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+ IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)5, 7, LAN Only EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, 13, 14, QLogic QLA4050−E−SP7, 11, 13, 15, 16 , QLogic CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLA4050C−E−SP7, 11, 15, 16, 17 AX100i
5 SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+ QLogic QLA4010−E−SP7, 8, 10, 11, 13 , QLogic LAN Only2 EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, QLA4010C−E−SP7, 8, 10, 11, 13 CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 AX100i
1. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
8. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Firmware Version 3.00.00.16
11. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
12. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Driver Version 5.00.04 Driver is integrated into the kernel.
14. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

11/02/2006 410 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

16. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.

SuSE SLES [IA64]

SuSE SLES [IA64]


Network External
No. Operating System Host Bus Adapter Configuration Storage Array Boot Comments
1 SuSE SLES [IA64] 9 SP2+: v2.6.5−7.201, Generic NIC 10/1001, Generic NIC LAN Only EMC CLARiiON N See2, 3
v2.6.5−7.202.7 GbE1 AX100i
1. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.

SuSE SLES [x86_64]

SuSE SLES [x86_64]


Network External
No. Operating System Host Bus Adapter Configuration Storage Array Boot Comments
1 SuSE SLES [x86_64] 10 Generic NIC 10/1005, 8, Generic NIC GbE5 LAN Only EMC CLARiiON AX100i N See6, 7
2 SuSE SLES [x86_64] 10 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 2, 3, 4 LAN Only EMC CLARiiON AX100i N

1. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. Driver Version 5.00.04−d5 Driver is integrated into the kernel.
4. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Driver Version iSCSI Software Initiator 1.0−595 Driver is integrated into the kernel.
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
8. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.

VMware ESX Server

VMware ESX Server


Host Bus Network External
No. Operating System Adapter Configuration Storage Array Boot
1 VMware ESX Server: Generic NIC LAN Only EMC CLARiiON N
v3.0, v3.0.1 GbE1 AX100i
2 VMware ESX Server: Generic NIC LAN Only2 EMC CLARiiON N
v3.0, v3.0.1 GbE1 AX100i
3 VMware ESX Server: Generic NIC LAN Only3 EMC CLARiiON N
v3.0, v3.0.1 GbE1 AX100i
1. Driver Version iSCSI initiator 3.4.2 This driver is included in the VMware ESX kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. Routed networks (layer 3) require iSCSI digest to be enabled.

iSCSI Clusters
Microsoft Windows 2003 [x64]
This table describes the support statements for iSCSI Clusters.

Microsoft Windows 2003 [x64]


Cluster Storage Max #
No. Operating System Software Host Bus Adapter Array Nodes Comments
1 Microsoft Windows 2003 [x64] Microsoft Generic NIC: 10/1008, GbE8 EMC HA: 8 See3, 4, 9
Enterprise: Edition, Edition R2 MSCS1, 2 CLARiiON
AX100i
2 Microsoft Windows 2003 [x64] Microsoft QLogic: QLA4010−E−SP6, 7, QLA4010C−E−SP6, 7, QLA4050−E−SP, EMC HA: 4 See3, 4, 5
Enterprise: Edition, Edition R2 MSCS1, 2 QLA4050C−E−SP6, 7, 10, 11, 12, 13, 14, 15 , QLA4052C−E−SP6, 7, 10, 11, 12, 13, 14, 15 CLARiiON
AX100i
1. Microsoft iSCSI Initiator required. Refer to Native iSCSI table for currently supported initiator version.
2. Booting from external storage for iSCSI clusters is not supported.
3. Microsoft Dynamic Disks are not supported.
4. iSCSI based cluster configurations require Microsoft QFE 824354. Please contact Microsoft Product Support Services for this QFE.
5. Booting from external array is supported for iSCSI clusters with QLA4010 iSCSI HBAs. Refer to Native iSCSI table for supported BIOS versions.
6. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
7. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
8. Any Microsoft supported server/NIC for the listed operating system revision is supported.
9. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.
10. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
11. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
12. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
13. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
14. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
15. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)

11/02/2006 411 CLARiiON AX100i


EMC CLARiiON AX100 Series Support Matrix

Microsoft Windows 2003 [x86]


This table describes the support statements for iSCSI Clusters.

Microsoft Windows 2003 [x86]


Cluster Storage Max #
No. Operating System Software Host Bus Adapter Array Nodes Comments
1 Microsoft Windows 2003 [x86] Microsoft Generic NIC: 10/10014, GbE14 EMC HA: 2 See11, 12,
Enterprise Edition MSCS1, 2 CLARiiON 15
AX100i
2 Microsoft Windows 2003 [x86] Microsoft Generic NIC: 10/10014, GbE14 EMC HA: 8 See11, 12,
Enterprise Edition: R2, SP1 MSCS1, 2 CLARiiON 15
AX100i
3 Microsoft Windows 2003 [x86] Microsoft IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 7; EMC HA: 4 See11, 12,
Enterprise: Edition, Edition R2, Edition MSCS1, 2 QLogic: QLA4010−E−SP4, 8, QLA4010C−E−SP4, 8, QLA4050−E−SP, CLARiiON 13
SP1; QLA4050C−E−SP3, 4, 5, 6, 7, 8, 9, 10 , QLA4052C−E−SP3, 4, 5, 6, 7, 8, 9, 10 AX100i
Microsoft Windows 2003 [x86] Storage:
Server, Server SP1
1. Microsoft iSCSI Initiator required. Refer to Native iSCSI table for currently supported initiator version.
2. Booting from external storage for iSCSI clusters is not supported.
3. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
4. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
5. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
6. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
7. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
8. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
9. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
10. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)
11. Microsoft Dynamic Disks are not supported.
12. iSCSI based cluster configurations require Microsoft QFE 824354. Please contact Microsoft Product Support Services for this QFE.
13. Booting from external array is supported for iSCSI clusters with QLA4010 iSCSI HBAs. Refer to Native iSCSI table for supported BIOS versions.
14. Any Microsoft supported server/NIC for the listed operating system revision is supported.
15. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

11/02/2006 412 CLARiiON AX100i


AX150i Rules
Configuration Rules: AX150i Storage Systems
Note: In this document, array means storage system.
Dedicated storage networks are highly recommended, but not required. Hosts can connect to an iSCSI array using a Layer 2 (switched) or Layer 3 (routed)
network. Also, the presence of VLANs, VPNs, or NAT devices on the network should be transparent to the array and are supported as long as the network
quality is adequate.

Switches, Routers, NICs


• Support is provided for industry−standard switches, routers, and Network Interface Cards (NICs).
• Supports up to four HBAs, or one (if the storage system has one SP) or two (if the storage system has two SPs) NICs per server connecting to one
storage system.
• A single server can not use HBAs and NICs to connect to the same storage system.
• Servers can use a combination of HBAs and NICs to connect to different storage systems.
• Separate servers, some with HBAs and some with NICs, can connect to the same storage system.
• A single server cannot use a combination of Fibre Channel HBAs and NICs or iSCSI HBAs to attach to a Fibre Channel storage system and an
iSCSI storage system at the same time.
• A single server can attach to CLARiiON AX150 iSCSI storage systems and thru IP/FC Switches to CLARiiON AX150 Fibre Channel storage systems
when there is common network configuration, failover software, and driver support for both platforms.
• A server can be connected to a maximum of four CLARiiON storage systems.
• An initiator can be connected to a maximum of eight array ports (four dual−SP arrays) or four array ports (four single−SP arrays), but no more than
four storage systems.

Environment and Configurability


• The connection to the array must be 1 Gb copper (RJ45).
Direct 10/100 NIC connections to the array are not supported, except to management ports.
• Direct−attach is via either 10/100/1000 NIC (operating at 1 Gb) or QLA4010C HBA.
• Initiators per SP port or storage system:

♦ A maximum of 10 initiators can be connected to a single SP AX150SCI port.


♦ A maximum of 10 hosts can connect to an AX150SCI.
♦ A maximum of 20 initiators can be connected to a dual SP AX150i.
♦ A maximum of 10 hosts can connect to an AX150i.
• Target array addresses and names must be configured manually in the Initiators.
• Server names and passwords must be configured manually in the iSCSI storage system.
• Authentication mechanism to be used is the Challenge Handshake Authentication Protocol (CHAP).

Considerations
• The AX150i and AX150SCi have two front−end iSCSI ports per storage processor.
• Currently, it is not possible to boot a Windows system using an iSCSI disk volume provided by the Microsoft iSCSI initiator. The only currently
supported method for booting a Windows system using an iSCSI disk volume is via a supported HBA.
• When using multiple NICs in the same server, up to two NICs per host are supported to one AX150I array. If multiple NICs are installed, it is
recommended that each be on a different subnet. If multiple NICs are on the same subnet, the MS Advanced configuration setup must be utilized in
order to take advantage of the additional NICs. If the Advanced configuration setup in the MS initiator is not used, additional NICs would be used
typically only in a failover situation.
• When HBAs and NICs are present in the same host, the Microsoft iSCSI initiator must not be used to control the HBAs. The HBA utility is the only
supported interface to the adapter.
• When using the Microsoft iSCSI initiator, all NICs in the same host will use the same iSCSI name. The name will identify the host and the NICs will
not be identifiable.
• When using QLogic iSCSI adapters, each HBA has a unique iSCSI name that identifies the individual HBA in the host.
• Dynamic disks are not supported on an iSCSI session using the Microsoft iSCSI initiator.
• EMC supports up to two nodes with iSCSI Windows server 2003 Cluster environments with the latest MS Initiator.

11/02/2006 413 AX150i Rules


CLARiiON AX150i
Native iSCSI
Haansoft Asianux Server 2.0 [32−Bit]

Haansoft Asianux Server 2.0 [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Haansoft Asianux Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N See2, 3
Server 2.0 [32−Bit] CLARiiON
SP1 AX150i
v2.6.9−34.21AX
2 Haansoft Asianux IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)11, 13, 14, 15 , QLogic QLA4050−E−SP7, 9, LAN Only EMC N
Server 2.0 [32−Bit] 11, 12, 13 , QLogic QLA4050−E−SP7, 9, 11, 12, 16 , QLogic QLA4050−E−SP7, 9, 11, 12, 17 , QLogic CLARiiON
SP1 QLA4050C−E−SP7, 9, 11, 12, 13 , QLogic QLA4050C−E−SP7, 9, 11, 12, 16 , QLogic AX150i
v2.6.9−34.21AX QLA4050C−E−SP7, 9, 10, 11, 12
3 Haansoft Asianux QLogic QLA4010−E−SP4, 5, 7, 11, 13 , QLogic QLA4010C−E−SP4, 5, 6, 7, 8 LAN Only2 EMC N
Server 2.0 [32−Bit] CLARiiON
SP1 AX150i
v2.6.9−34.21AX
1. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Firmware Version 3.00.00.16
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
8. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
11. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Driver is integrated into the kernel.

Haansoft Asianux Server 2.0 [AMD64]

Haansoft Asianux Server 2.0 [AMD64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Haansoft Asianux Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N See2, 3
Server 2.0 [AMD64] CLARiiON
SP1 v2.6.9−34.21AX AX150i
2 Haansoft Asianux IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, 13, 14, 15 , QLogic QLA4050−E−SP7, 9, 11, LAN Only EMC N
Server 2.0 [AMD64] 12, 13, QLogic QLA4050−E−SP7, 9, 11, 12, 16 , QLogic QLA4050−E−SP7, 9, 11, 12, 17 , QLogic CLARiiON
SP1 v2.6.9−34.21AX QLA4050C−E−SP7, 9, 11, 12, 13 , QLogic QLA4050C−E−SP7, 9, 11, 12, 16 , QLogic AX150i
QLA4050C−E−SP7, 9, 10, 11, 12
3 Haansoft Asianux QLogic QLA4010−E−SP4, 5, 7, 9, 13 , QLogic QLA4010C−E−SP4, 5, 6, 7, 8 LAN Only2 EMC N
Server 2.0 [AMD64] CLARiiON
SP1 v2.6.9−34.21AX AX150i
1. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Firmware Version 3.00.00.16
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
8. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
11. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Driver is integrated into the kernel.

Haansoft Asianux Server 2.0 [EM64T]

Haansoft Asianux Server 2.0 [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Haansoft Asianux Generic NIC 10/1008, Generic NIC GbE8 LAN Only EMC N See2, 7
Server 2.0 [EM64T] CLARiiON
SP1 v2.6.9−34.21AX AX150i

11/02/2006 414 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

Haansoft Asianux Server 2.0 [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
2 Haansoft Asianux IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, 13, 14, 15 , QLogic QLA4050−E−SP5, 9, 10, LAN Only EMC N
Server 2.0 [EM64T] 11, 13, QLogic QLA4050−E−SP5, 9, 10, 11, 16 , QLogic QLA4050−E−SP5, 9, 10, 11, 17 , QLogic CLARiiON
SP1 v2.6.9−34.21AX QLA4050C−E−SP5, 9, 10, 11, 12 , QLogic QLA4050C−E−SP5, 9, 10, 11, 13 , QLogic AX150i
QLA4050C−E−SP5, 9, 10, 11, 16
3 Haansoft Asianux QLogic QLA4010−E−SP1, 3, 5, 9, 13 , QLogic QLA4010C−E−SP1, 3, 4, 5, 6 LAN Only2 EMC N
Server 2.0 [EM64T] CLARiiON
SP1 v2.6.9−34.21AX AX150i
1. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. Firmware Version 3.00.00.16
4. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
8. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04 Driver is integrated into the kernel.

Haansoft Linux 2005 Server Asianux Inside [32−Bit]

Haansoft Linux 2005 Server Asianux Inside [32−Bit]


Host Bus Network Storage External
No. Operating System Adapter Configuration Array Boot
1 Haansoft Linux 2005 Generic NIC LAN Only EMC N
Server Asianux Inside 10/1001, CLARiiON
[32−Bit] v2.4.21−37.18AX Generic NIC AX150i
GbE1
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the
kernel.

Haansoft Linux 2005 Server Asianux Inside [AMD64]

Haansoft Linux 2005 Server Asianux Inside [AMD64]


Host Bus Network Storage External
No. Operating System Adapter Configuration Array Boot
1 Haansoft Linux 2005 Generic NIC LAN Only EMC N
Server Asianux Inside 10/1001, CLARiiON
[AMD64] Generic NIC AX150i
v2.4.21−37.18AX GbE1
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the
kernel.

Haansoft Linux 2005 Server Asianux Inside [EM64T]

Haansoft Linux 2005 Server Asianux Inside [EM64T]


Host Bus Network Storage External
No. Operating System Adapter Configuration Array Boot
1 Haansoft Linux 2005 Generic NIC LAN Only EMC N
Server Asianux Inside 10/1001, CLARiiON
[EM64T] Generic NIC AX150i
v2.4.21−37.18AX GbE1
1. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the
kernel.

IBM AIX

IBM AIX
Network External
No. Operating System Host Bus Adapter Configuration Storage Array Boot
1 IBM AIX 5.2 Generic NIC 10/1007, 8, Generic NIC LAN Only9, 10 EMC CLARiiON AX150i1, 2, N
5.2.0.0−085, 6 GbE7, 8 3, 4

1. Navisphere Host Agent Version 6.20.1.5.0 supported only.


2. Requires Flare 02.20.150.5.019 or later for support.
3. Requires Full Navi only. Navisphere Express is not supported.
4. No layered apps support.
5. iSCSI support limited only to the IBM BladeCenter, JS20 model 8842, and JS21 model 8844.
6. Requires AIX 5.2.0.0−08 (TL 8) for support.
7. Driver Version Native AIX Driver
8. Firmware Version 03210230
9. EMC requires the Nortel Networks Layer2−3 GbE Switch Module for external communication on the IBM JS20/JS21 BladeCenter.
10. EMC supports the Cisco Catalyst 4500 Series network switches, running IOS firmware version 12.2(25).

11/02/2006 415 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

Microsoft Windows 2000

Microsoft Windows 2000


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Microsoft Windows Generic NIC 10/10018, 19, 20, 21 , Generic NIC GbE18, 19, 20, 21 LAN Only16 EMC N See2, 3, 4,
2000: Advanced CLARiiON 15, 17
Server SP4, Server AX150i14
SP4
2 Microsoft Windows IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, 9, 11, 22, 23, 24 , QLogic LAN Only15, 16 EMC Y1 See2, 3, 4
2000: Advanced QLA4010−E−SP5, 8, 9, 11, 12, 13, 25, 26, 27 , QLogic QLA4010C−E−SP5, 8, 9, 11, 12, 13, 25, 26, 27 , CLARiiON
Server SP4, Server QLogic QLA4050−E−SP5, 6, 7, 8, 9, 10, 11, 12, 13 , QLogic QLA4050C−E−SP5, 6, 7, 8, 9, 10, 11, 12, 13 AX150i14
SP4
1. Servers booting from external storage with QLA4010 iSCSI boards require Microsoft iSCSI Initiator 2.0 or 2.02 service to be installed. Note that HBA IQN must be altered prior to
Windows installation. Refer to EMC Host Connectivity Guide for information on changing IQN and setting up boot for servers requiring MS iSCSI Initiator service.
2. Microsoft Dynamic Disks are not supported.
3. Powerpath iSCSI 1.1 is not supported with Windows 2000 operating systems.
4. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
5. Driver Version 2.1.3.3
6. Firmware Version 2.0.0.38
7. BIOS 1.08
8. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
9. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
10. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
11. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
12. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
13. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
14. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
15. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
16. Routed networks (layer 3) require iSCSI digest to be enabled.
17. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
18. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
19. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
20. The following NICs are not supported: 3COM−3C996B
21. Any Microsoft supported server/NIC for the listed operating system revision is supported.
22. BIOS 1.04
23. Driver Version 2.1.1.0
24. Firmware Version 2.00.00.07
25. Driver Version 2.1.0.3
26. Firmware Version 3.0.0.16
27. BIOS 1.11

Microsoft Windows 2003 [x64]

Microsoft Windows 2003 [x64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Microsoft Windows 2003 [x64] Generic NIC 10/1008, 9, 10, 11 , Generic NIC GbE8, 9, 10, 11 LAN Only7 EMC N See2, 3, 4,
Enterprise: Edition, Edition R2; CLARiiON 5, 6
AX150i1
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2;
Microsoft Windows 2003 [x64]
Storage Server: Enterprise Edition
R221, Standard Edition R221
2 Microsoft Windows 2003 [x64] QLogic QLA4010−E−SP12, 13, 14, 15, 16, 17, 18, 19, 20 , QLogic QLA4010C−E−SP12, LAN Only2, 7 EMC N See3, 5, 6
Enterprise: Edition, Edition R2; 13, 14, 15, 16, 17, 18, 19, 20 , QLogic QLA4050−E−SP13, 25, 26 , QLogic CLARiiON
QLA4050C−E−SP13, 16, 17, 18, 19, 20, 22, 23, 24, 25, 26 AX150i1
Microsoft Windows 2003 [x64]
Standard: Edition, Edition R2;
Microsoft Windows 2003 [x64]
Storage Server: Enterprise Edition
R221, Standard Edition R221
1. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. Microsoft Dynamic Disks are not supported.
4. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
5. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
6. Powerpath iSCSI 1.1 is supported with Windows 2003 operating systems.
7. Routed networks (layer 3) require iSCSI digest to be enabled.
8. The following NICs are not supported: 3COM−3C996B
9. Any Microsoft supported server/NIC for the listed operating system revision is supported.
10. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
11. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
12. Firmware Version 3.0.0.16
13. Driver Version 2.1.3.8
14. Driver Version 2.1.0.8
15. BIOS 1.11
16. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
17. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
18. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
19. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
20. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
21.

11/02/2006 416 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

Support for Windows 2003 Storage Server is limited to the connection to EMC storage arrays. Currently, Windows 2003 Storage Server is not supported in target mode for iSCSI
configurations.
22. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
23. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
24. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)
25. Firmware Version 2.0.0.38
26. BIOS 1.08

Microsoft Windows 2003 [x86]

Microsoft Windows 2003 [x86]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Microsoft Windows 2003 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)7, 10, 20, 21, 22 , QLogic LAN Only15, 16 EMC Y1 See3, 4, 5
[x86] Enterprise: Edition, QLA4010−E−SP6, 7, 10, 11, 12, 18, 28, 29, 30 , QLogic QLA4010C−E−SP6, 7, 10, 11, 12, 18, 28, 29, CLARiiON
Edition R2, Edition SP1; 30,QLogic QLA4050−E−SP2, 17, 18, QLogic QLA4050C−E−SP2, 6, 7, 8, 9, 10, 11, 12, 13, 17, 18 AX150i14
Microsoft Windows 2003
[x86] Standard: Edition,
Edition R2, Edition SP1;
Microsoft Windows 2003
[x86] Storage Server
Enterprise Edition: R219,
SP119;
Microsoft Windows 2003
[x86] Storage Server:
Enterprise Edition19, R219,
SP119;
Microsoft Windows 2003
[x86] Storage Server19
2 Microsoft Windows 2003 Generic NIC 10/10023, 24, 25, 26 , Generic NIC GbE23, 24, 25, 26 LAN Only16 EMC N See3, 4, 5,
[x86] Enterprise: Edition, CLARiiON 15, 27
Edition R2; AX150i14
Microsoft Windows 2003
[x86] Standard: Edition,
Edition R2;
Microsoft Windows 2003
[x86] Storage Server
Enterprise Edition: R219,
SP119;
Microsoft Windows 2003
[x86] Storage Server:
Enterprise Edition19, R219,
SP119;
Microsoft Windows 2003
[x86] Storage Server19
3 Microsoft Windows 2003 Generic NIC 10/10023, 24, 25, 26 , Generic NIC GbE23, 24, 25, 26 LAN Only16 EMC Y31 See3, 4, 5,
[x86]: Enterprise Edition CLARiiON 15, 27
SP1, Standard Edition SP1 AX150i14
1. Servers booting from external storage with QLA4010 iSCSI boards require Microsoft iSCSI Initiator 2.0 or 2.02 service to be installed. Note that HBA IQN must be altered prior to
Windows installation. Refer to EMC Host Connectivity Guide for information on changing IQN and setting up boot for servers requiring MS iSCSI Initiator service.
2. Firmware Version 2.0.0.38
3. Microsoft Dynamic Disks are not supported.
4. Powerpath 4.3.1 or higher is supported. All paths may be on a single subnet, or multiple subnets may be used.
5. Powerpath iSCSI 1.1 is supported with Windows 2003 operating systems.
6. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
7. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
8. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
9. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
10. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
11. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
12. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
13. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)
14. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
15. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
16. Routed networks (layer 3) require iSCSI digest to be enabled.
17. BIOS 1.08
18. Driver Version 2.1.3.8
19. Support for Windows 2003 Storage Server is limited to the connection to EMC storage arrays. Currently, Windows 2003 Storage Server is not supported in target mode for iSCSI
configurations.
20. BIOS 1.04
21. Firmware Version 2.00.00.07
22. Driver Version 2.1.1.5
23. Driver Version Microsoft iSCSI Initiator 2.0 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
24. Driver Version Microsoft iSCSI Initiator 2.02 Microsoft iSCSI Initiator software NIC teaming with Microsoft iSCSI Initiator is not supported. EMC recommends that on hosts with multiple
NICs that the Software Initiator Source_IP default selection not be used, and a NIC be explicitly selected for maximum path availability. Refer to the EMC Host Connectivity Guide for
more detailed information.
25. The following NICs are not supported: 3COM−3C996B
26. Any Microsoft supported server/NIC for the listed operating system revision is supported.
27. EMC provides documentation for iSCSI configurations that contains helpful information for using iSCSI with EMC storage. Visit EMC Powerlink and download part number 300−000−603
for the Windows Host Connectivity Guide.
28. BIOS 1.11
29. Firmware Version 3.0.0.16
30. Driver Version 2.1.0.8
31. iSCSI Boot from SAN only supported on IBM BladeCenter HS20 (8843). Requires Microsoft iSCSI Initiator 2.02 with boot supported. Contact IBM support to obtain this software.

MiracleLinux MLSE [32−Bit]

11/02/2006 417 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

MiracleLinux MLSE [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 MiracleLinux MLSE Generic NIC 10/1001, Generic NIC GbE1 LAN Only3 EMC N See2
[32−Bit] 3.0 SP1 CLARiiON
v2.4.21−20.19AX AX150i
2 MiracleLinux MLSE Generic NIC 10/10017, Generic NIC GbE17 LAN Only EMC N
[32−Bit] 3.0 SP2 CLARiiON
v2.4.21−37.18AX AX150i
3 MiracleLinux MLSE Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N
[32−Bit] 4.0 GA CLARiiON
v2.6.9−11.19AX AX150i
4 MiracleLinux MLSE Generic NIC 10/1004, Generic NIC GbE4 LAN Only EMC N See2, 3
[32−Bit] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
5 MiracleLinux MLSE IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)5, 10, 11, 12 , QLogic QLA4050−E−SP5, 6, 7, LAN Only EMC N
[32−Bit] 4.0 SP1 8, 13, QLogic QLA4050−E−SP5, 6, 7, 8, 16 , QLogic QLA4050−E−SP5, 6, 7, 8, 10 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP5, 6, 7, 8, 13 , QLogic QLA4050C−E−SP5, 6, 7, 8, 9 , QLogic QLA4050C−E−SP5, 6, 7, AX150i
8, 10

6 MiracleLinux MLSE QLogic QLA4010−E−SP5, 6, 10, 14, 15 , QLogic QLA4010C−E−SP6, 14, 15, 19, 20 LAN Only3 EMC N
[32−Bit] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
5. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Driver is integrated into the kernel.
17. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
18. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
19. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com

MiracleLinux MLSE [AMD64]

MiracleLinux MLSE [AMD64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 MiracleLinux MLSE Generic NIC 10/10016, Generic NIC GbE16 LAN Only EMC N
[AMD64] 3.0 SP2 CLARiiON
v2.4.21−37.18AX AX150i
2 MiracleLinux MLSE Generic NIC 10/10017, Generic NIC GbE17 LAN Only EMC N
[AMD64] 4.0 GA CLARiiON
v2.6.9−11.19AX AX150i
3 MiracleLinux MLSE Generic NIC 10/1003, Generic NIC GbE3 LAN Only EMC N See1, 2
[AMD64] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
4 MiracleLinux MLSE IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)4, 9, 10, 11 , QLogic QLA4050−E−SP4, 5, 7, 8, LAN Only EMC N
[AMD64] 4.0 SP1 12,QLogic QLA4050−E−SP4, 5, 7, 8, 13 , QLogic QLA4050−E−SP4, 5, 7, 8, 10 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP4, 5, 6, 7, 8 , QLogic QLA4050C−E−SP4, 5, 7, 8, 12 , QLogic QLA4050C−E−SP4, 5, 7, AX150i
8, 10

5 MiracleLinux MLSE QLogic QLA4010−E−SP4, 5, 10, 14, 15 , QLogic QLA4010C−E−SP5, 14, 15, 18, 19 LAN Only1 EMC N
[AMD64] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
7. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Driver is integrated into the kernel.
14. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Firmware Version 3.00.00.16
16. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
17. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
18. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com

11/02/2006 418 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

MiracleLinux MLSE [EM64T]

MiracleLinux MLSE [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 MiracleLinux MLSE Generic NIC 10/10014, Generic NIC GbE14 LAN Only7 EMC N See8
[EM64T] 3.0 GA CLARiiON
v2.4.21−20.19AX AX150i
2 MiracleLinux MLSE Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N
[EM64T] 3.0 SP2 CLARiiON
v2.4.21−37.18AX AX150i
3 MiracleLinux MLSE Generic NIC 10/1001, Generic NIC GbE1 LAN Only EMC N
[EM64T] 4.0 GA CLARiiON
v2.6.9−11.19AX AX150i
4 MiracleLinux MLSE Generic NIC 10/1009, Generic NIC GbE9 LAN Only EMC N See7, 8
[EM64T] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
5 MiracleLinux MLSE IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)5, 10, 11, 12 , QLogic QLA4050−E−SP2, 3, 5, LAN Only EMC N
[EM64T] 4.0 SP1 6, 11,
QLogic QLA4050−E−SP2, 3, 5, 6, 13 , QLogic QLA4050−E−SP2, 3, 5, 6, 15 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP2, 3, 4, 5, 6 , QLogic QLA4050C−E−SP2, 3, 5, 6, 11 , QLogic QLA4050C−E−SP2, 3, 5, AX150i
6, 13

6 MiracleLinux MLSE QLogic QLA4010−E−SP5, 6, 11, 16, 17 , QLogic QLA4010C−E−SP6, 16, 17, 19, 20 LAN Only7 EMC N
[EM64T] 4.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
1. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
2. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
5. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
10. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Firmware Version 3.00.00.16
17. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI Software Initiator 3.6.2.1 Driver is integrated into the kernel.
19. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com

Oracle Enterprise Linux [32−Bit]

Oracle Enterprise Linux [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Oracle Enterprise Linux [32−Bit] 4 Generic NIC 10/10011, Generic NIC GbE11 LAN Only EMC N See9, 10
U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX150i
2 Oracle Enterprise Linux [32−Bit] 4 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 3, 6, 7, 8 , QLogic LAN Only EMC N
U4 v2.6.9−42.0.0.0.1.EL QLA4050−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX150i
3 Oracle Enterprise Linux [32−Bit] 4 QLogic QLA4010−E−SP1, 2, 3, 12, 13 , QLogic QLA4010C−E−SP2, 3, 12, 13, 14 LAN Only9 EMC N
U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX150i
1. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
2. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
3. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Firmware Version 2.00.00.38
8. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
10. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
11. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
12. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 3.00.00.16
14. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Oracle Enterprise Linux [AMD−64]

11/02/2006 419 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

Oracle Enterprise Linux [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Oracle Enterprise Linux [AMD−64] Generic NIC 10/10014, Generic NIC GbE14 LAN Only EMC N See2, 15
4 U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX150i
2 Oracle Enterprise Linux [AMD−64] IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)7, 10, 11, 12, 13 , QLogic LAN Only EMC N
4 U4 v2.6.9−42.0.0.0.1.EL QLA4050−E−SP5, 7, 8, 9, 10 , QLogic QLA4050C−E−SP5, 7, 8, 9, 10 CLARiiON
AX150i
3 Oracle Enterprise Linux [AMD−64] QLogic QLA4010−E−SP1, 3, 5, 7, 10 , QLogic QLA4010C−E−SP1, 3, 4, 5, 6 LAN Only2 EMC N
4 U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX150i
1. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
3. Firmware Version 3.00.00.16
4. Driver Version 5.00.07
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
9. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. Firmware Version 2.00.00.38
13. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
15. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.

Oracle Enterprise Linux [EM64T]

Oracle Enterprise Linux [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Oracle Enterprise Linux [EM64T] 4 Generic NIC 10/10011, Generic NIC GbE11 LAN Only EMC N See9, 10
U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX150i
2 Oracle Enterprise Linux [EM64T] 4 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 3, 6, 7, 8 , QLogic LAN Only EMC N
U4 v2.6.9−42.0.0.0.1.EL QLA4050−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX150i
3 Oracle Enterprise Linux [EM64T] 4 QLogic QLA4010−E−SP1, 2, 3, 12, 13 , QLogic QLA4010C−E−SP2, 3, 12, 13, 14 LAN Only9 EMC N
U4 v2.6.9−42.0.0.0.1.EL CLARiiON
AX150i
1. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
2. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
3. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Firmware Version 2.00.00.38
7. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
10. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
11. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
12. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 3.00.00.16
14. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

Red Flag DC Server [32−Bit]

Red Flag DC Server [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Flag DC Server Generic NIC 10/1002, Generic NIC GbE2 LAN Only1 EMC N See3
[32−Bit] 4.1 SP1 CLARiiON
v2.4.21−20.19AX AX150i
2 Red Flag DC Server Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N
[32−Bit] 5.0 GA CLARiiON
v2.6.9−11.19AX AX150i
3 Red Flag DC Server Generic NIC 10/10013, Generic NIC GbE13 LAN Only EMC N See1, 3
[32−Bit] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
4 Red Flag DC Server IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)9, 14, 15, 16 , QLogic QLA4050−E−SP7, 9, 10, LAN Only EMC N
[32−Bit] 5.0 SP1 12, 14, QLogic QLA4050−E−SP7, 9, 10, 12, 17 , QLogic QLA4050−E−SP7, 9, 10, 12, 19 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP7, 9, 10, 11, 12 , QLogic QLA4050C−E−SP7, 9, 10, 12, 14 , QLogic QLA4050C−E−SP7, AX150i
9, 10, 12, 17

5 Red Flag DC Server QLogic QLA4010−E−SP4, 5, 7, 9, 14 , QLogic QLA4010C−E−SP4, 5, 6, 7, 8 LAN Only1 EMC N
[32−Bit] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i

11/02/2006 420 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
3. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
4. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. Firmware Version 3.00.00.16
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
8. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
19. Driver Version 5.00.04 Driver is integrated into the kernel.

Red Flag DC Server [AMD64]

Red Flag DC Server [AMD64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Flag DC Generic NIC 10/10017, Generic NIC GbE17 LAN Only EMC N
Server [AMD64] 5.0 CLARiiON
GA v2.6.9−11.19AX AX150i
2 Red Flag DC Generic NIC 10/1008, Generic NIC GbE8 LAN Only EMC N See6, 7
Server [AMD64] 5.0 CLARiiON
SP1 AX150i
v2.6.9−34.21AX
3 Red Flag DC IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)10, 13, 14, 15 , QLogic QLA4050−E−SP4, 9, 10, LAN Only EMC N
Server [AMD64] 5.0 12, 14,
QLogic QLA4050−E−SP4, 9, 10, 12, 16 , QLogic QLA4050−E−SP4, 9, 10, 12, 18 , QLogic CLARiiON
SP1 QLA4050C−E−SP4, 9, 10, 11, 12 , QLogic QLA4050C−E−SP4, 9, 10, 12, 14 , QLogic QLA4050C−E−SP4, AX150i
v2.6.9−34.21AX 9, 10, 12, 16

4 Red Flag DC QLogic QLA4010−E−SP1, 3, 4, 10, 14 , QLogic QLA4010C−E−SP1, 2, 3, 4, 5 LAN Only6 EMC N
Server [AMD64] 5.0 CLARiiON
SP1 AX150i
v2.6.9−34.21AX
1. Firmware Version 3.00.00.16
2. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
5. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
7. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
8. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
9. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
10. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.
18. Driver Version 5.00.04 Driver is integrated into the kernel.

Red Flag DC Server [EM64T]

Red Flag DC Server [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Flag DC Server Generic NIC 10/10017, Generic NIC GbE17 LAN Only4 EMC N See12
[EM64T] 4.1 GA CLARiiON
v2.4.21−20.19AX AX150i
2 Red Flag DC Server Generic NIC 10/10019, Generic NIC GbE19 LAN Only EMC N
[EM64T] 5.0 GA CLARiiON
v2.6.9−11.19AX AX150i
3 Red Flag DC Server Generic NIC 10/10011, Generic NIC GbE11 LAN Only EMC N See4, 12
[EM64T] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i
4 Red Flag DC Server IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, 13, 14, 15 , QLogic QLA4050−E−SP2, 7, 8, LAN Only EMC N
[EM64T] 5.0 SP1 10, 13, QLogic QLA4050−E−SP2, 7, 8, 10, 16 , QLogic QLA4050−E−SP2, 7, 8, 10, 18 , QLogic CLARiiON
v2.6.9−34.21AX QLA4050C−E−SP2, 7, 8, 9, 10 , QLogic QLA4050C−E−SP2, 7, 8, 10, 13 , QLogic QLA4050C−E−SP2, 7, AX150i
8, 10, 16

5 Red Flag DC Server QLogic QLA4010−E−SP1, 2, 6, 8, 13 , QLogic QLA4010C−E−SP1, 2, 3, 5, 6 LAN Only4 EMC N
[EM64T] 5.0 SP1 CLARiiON
v2.6.9−34.21AX AX150i

11/02/2006 421 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

1. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
3. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
4. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
5. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. Firmware Version 3.00.00.16
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
10. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
12. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
15. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version iSCSI Initiator 3.6.2−3 Available from the OS distributor by request.
18. Driver Version 5.00.04 Driver is integrated into the kernel.
19. Driver Version iSCSI Software Initiator 4:0.1.11 Driver is integrated into the kernel.

Red Hat RHEL [32−Bit]

Red Hat RHEL [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 6, 9, 27, QLogic LAN Only EMC N
QLA4010C−E−SP6, 9, 27 CLARiiON
AX150i
2 Red Hat RHEL [32−Bit] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 6, 9, 27, QLogic LAN Only EMC N See7, 16
QLA4010C−E−SP6, 9, 27 CLARiiON
AX150i
3 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES v2.4.21−47.EL IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
(26K6487)4, 22, 23, 24 , QLogic QLA4010−E−SP4, 6, 9, 24, CLARiiON
QLogic QLA4010C−E−SP6, 9, 24, QLogic AX150i
QLA4050−E−SP1, 3, 4, 5, 24 , QLogic QLA4050C−E−SP1,
3, 4, 5, 24

4 Red Hat RHEL [32−Bit] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP4, 6, 9, 24, QLogic LAN Only EMC N See7, 16
QLA4010C−E−SP6, 9, 24 CLARiiON
AX150i
5 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/10017, Generic NIC GbE15, 17 LAN Only EMC N See7, 16
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX150i
6 Red Hat RHEL [32−Bit] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 6, 9, 12 , QLogic LAN Only7 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 6, 8, 9, 10 CLARiiON
AX150i
7 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)2, 4, 22, 26 CLARiiON
AX150i
8 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP1, 2, 3, 4, 5 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP1, 2, 3, 4, 5 CLARiiON
AX150i
Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [32−Bit] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10025, Generic NIC GbE25 LAN Only EMC N See7, 16
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX150i
10 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)4, 14, 21, 22 , QLogic QLA4050−E−SP1, 3, 4, 5, CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 14, QLogic QLA4050C−E−SP1, 3, 4, 5, 14 AX150i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP4, 5, 6, 9, 14 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 6, 8, 9, 13 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [32−Bit] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N See7, 16
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [32−Bit] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP1, 3, 4, 5, 20 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP1, 3, 4, 5, 19 CLARiiON
AX150i
14 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 11, 21, 22, 23 , QLogic QLA4050−E−SP1, 3, 4, CLARiiON
5, 11,
QLogic QLA4050C−E−SP1, 3, 4, 5, 11 AX150i
15 Red Hat RHEL [32−Bit] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 6, 9, 11 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 6, 8, 9, 11 CLARiiON
AX150i
1. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. Firmware Version 3.00.00.16
10. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

11/02/2006 422 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

15. The following NICs are not supported: 3COM−3C996B


16. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
17. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
18. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
20. Driver Version 5.00.04 Driver is integrated into the kernel.
21. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
22. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Firmware Version 2.00.00.38
24. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
25. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
26. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
27. Driver Version 3.22

Red Hat RHEL [AMD−64]

Red Hat RHEL [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Hat RHEL [AMD−64] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP8, 12, 14, 22 , QLogic LAN Only EMC N
QLA4010C−E−SP12, 14, 22 CLARiiON
AX150i
2 Red Hat RHEL [AMD−64] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP8, 12, 14, 22 , QLogic LAN Only EMC N See3, 4
QLA4010C−E−SP12, 14, 22 CLARiiON
AX150i
3 Red Hat RHEL [AMD−64] 3.0 U8 AS/ES v2.4.21−47.EL IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
(26K6487)8, 17, 21, 23 , QLogic QLA4010−E−SP8, 12, 14, CLARiiON
21,QLogic QLA4010C−E−SP12, 14, 21, QLogic AX150i
QLA4050−E−SP5, 7, 8, 9, 21 , QLogic QLA4050C−E−SP5,
7, 8, 9, 21

4 Red Hat RHEL [AMD−64] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP8, 12, 14, 21 , QLogic LAN Only EMC N See3, 4
QLA4010C−E−SP12, 14, 21 CLARiiON
AX150i
5 Red Hat RHEL [AMD−64] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/1001, Generic NIC GbE1, 2 LAN Only EMC N See3, 4
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX150i
6 Red Hat RHEL [AMD−64] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP8, 9, 12, 14, 28 , QLogic LAN Only3 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP9, 11, 12, 14, 27 CLARiiON
AX150i
7 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)8, 10, 17, 20 CLARiiON
AX150i
8 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP5, 7, 8, 9, 10 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP5, 7, 8, 9, 10 CLARiiON
AX150i
Red Hat RHEL [AMD−64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [AMD−64] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N See3, 4
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX150i
10 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)6, 8, 16, 17 , QLogic QLA4050−E−SP5, 6, 7, 8, 9 , CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES QLogic QLA4050C−E−SP5, 6, 7, 8, 9 AX150i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP6, 8, 9, 12, 14 , QLogic LAN Only3 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP9, 11, 12, 13, 14 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [AMD−64] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10015, Generic NIC GbE15 LAN Only EMC N See3, 4
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [AMD−64] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP5, 7, 8, 9, 25 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP5, 7, 8, 9, 24 CLARiiON
AX150i
14 Red Hat RHEL [AMD−64] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)8, 16, 17, 19, 23 , QLogic QLA4050−E−SP5, 7, 8, CLARiiON
9, 19, QLogic QLA4050C−E−SP5, 7, 8, 9, 19 AX150i
15 Red Hat RHEL [AMD−64] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP8, 9, 12, 14, 19 , QLogic LAN Only3 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP9, 11, 12, 14, 26 CLARiiON
AX150i
1. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
2. The following NICs are not supported: 3COM−3C996B
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
5. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
10. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
12. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
16. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
19. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
21. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

11/02/2006 423 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

22. Driver Version 3.22


23. Firmware Version 2.00.00.38
24. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
25. Driver Version 5.00.04 Driver is integrated into the kernel.
26. Driver Version 5.00.07
27. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
28. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

Red Hat RHEL [EM64T]

Red Hat RHEL [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 14, 15, 23 , QLogic LAN Only EMC N
QLA4010C−E−SP14, 15, 23 CLARiiON
AX150i
2 Red Hat RHEL [EM64T] 3.0 U7 AS/ES v2.4.21−40.EL QLogic QLA4010−E−SP4, 14, 15, 23 , QLogic LAN Only EMC N See7, 8
QLA4010C−E−SP14, 15, 23 CLARiiON
AX150i
3 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
(26K6487)1, 4, 11, 19 , QLogic QLA4010−E−SP1, 4, 14, 15 , CLARiiON
QLogic QLA4010C−E−SP 1, 14, 15 , QLogic AX150i
QLA4050−E−SP1, 2, 3, 4, 5 , QLogic QLA4050C−E−SP1,
2, 3, 4, 5

4 Red Hat RHEL [EM64T] 3.0 U8 AS/ES v2.4.21−47.EL QLogic QLA4010−E−SP1, 4, 14, 15 , QLogic LAN Only EMC N See7, 8
QLA4010C−E−SP1, 14, 15 CLARiiON
AX150i
5 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ Generic NIC 10/1006, Generic NIC GbE6, 9 LAN Only EMC N See7, 8
AS/ES v2.4.21−32.0.1.EL CLARiiON
AX150i
6 Red Hat RHEL [EM64T] 3.0: U5 AS/ES v2.4.21−32.EL, U5+ QLogic QLA4010−E−SP4, 5, 14, 15, 27 , QLogic LAN Only7 EMC N
AS/ES v2.4.21−32.0.1.EL QLA4010C−E−SP5, 14, 15, 16, 26 CLARiiON
AX150i
7 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL (26K6487)4, 11, 21, 22 CLARiiON
AX150i
8 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ QLogic QLA4050−E−SP2, 3, 4, 5, 22 , QLogic LAN Only EMC N
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL; QLA4050C−E−SP2, 3, 4, 5, 22 CLARiiON
AX150i
Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL
9 Red Hat RHEL [EM64T] 3.0: U6 AS/ES v2.4.21−37.EL, U6+ Generic NIC 10/10020, Generic NIC GbE20 LAN Only EMC N See7, 8
AS/ES v2.4.21−37.0.1.EL, U7 AS/ES v2.4.21−40.EL, U8 AS/ES CLARiiON
v2.4.21−47.EL AX150i
10 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 (26K6487)4, 10, 11, 12 , QLogic QLA4050−E−SP2, 3, 4, 5, CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES 10,QLogic QLA4050C−E−SP2, 3, 4, 5, 10 AX150i
v2.6.9−34.0.2.EL
11 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ QLogic QLA4010−E−SP4, 5, 10, 14, 15 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 QLA4010C−E−SP5, 13, 14, 15, 16 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL
12 Red Hat RHEL [EM64T] 4.0: U2 AS/ES v2.6.9−22.EL, U2+ Generic NIC 10/10017, Generic NIC GbE17 LAN Only EMC N See7, 8
AS/ES v2.6.9−22.0.1.EL, U2+ AS/ES v2.6.9−22.0.2.EL, U3 CLARiiON
AS/ES v2.6.9−34.EL, U3+ AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES AX150i
v2.6.9−34.0.2.EL, U4 AS/ES v2.6.9−42.EL, U4+ AS/ES
v2.6.9−42.0.2.EL
13 Red Hat RHEL [EM64T] 4.0: U3 AS/ES v2.6.9−34.EL, U3+ QLogic QLA4050−E−SP2, 3, 4, 5, 25 , QLogic LAN Only EMC N
AS/ES v2.6.9−34.0.1.EL, U3+ AS/ES v2.6.9−34.0.2.EL QLA4050C−E−SP2, 3, 4, 5, 24 CLARiiON
AX150i
14 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ IBM QLogic iSCSI Exp Card for BladeCenter LAN Only EMC N
AS/ES v2.6.9−42.0.2.EL (26K6487)4, 11, 12, 18, 19 , QLogic QLA4050−E−SP2, 3, 4, CLARiiON
5, 18, QLogic QLA4050C−E−SP2, 3, 4, 5, 18 AX150i
15 Red Hat RHEL [EM64T] 4.0: U4 AS/ES v2.6.9−42.EL, U4+ QLogic QLA4010−E−SP4, 5, 14, 15, 18 , QLogic LAN Only7 EMC N
AS/ES v2.6.9−42.0.2.EL QLA4010C−E−SP5, 14, 15, 16, 18 CLARiiON
AX150i
1. Driver Version 3.27 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
6. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. The following NICs are not supported: 3COM−3C996B
10. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
11. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
14. Firmware Version 3.00.00.16
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Driver Version iSCSI Software Initiator 4.0.1.11 Driver is integrated into the kernel.
18. Driver Version 5.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Firmware Version 2.00.00.38
20. Driver Version iSCSI initiator 3.6.3 Driver is integrated into the kernel.
21. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
22. Driver Version 3.23 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
23. Driver Version 3.22
24. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
25. Driver Version 5.00.04 Driver is integrated into the kernel.
26. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com

11/02/2006 424 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

27. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com

SuSE SLES [32−Bit]

SuSE SLES [32−Bit]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [32−Bit] 10 Generic NIC 10/10021, Generic NIC GbE22, 23 LAN Only EMC N See3, 10
CLARiiON
AX150i
2 SuSE SLES [32−Bit] 10 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, LAN Only EMC N
16, 17, 18 CLARiiON
AX150i
3 SuSE SLES [32−Bit] 8 SP4+: v2.4.21−281, v2.4.21−286, Generic NIC 10/10011, Generic NIC GbE9, 11 LAN Only EMC N See3, 10
v2.4.21−295, v2.4.21−304, v2.4.21−306, v2.4.21−309 CLARiiON
AX150i
4 SuSE SLES [32−Bit] 8: SP4 v2.4.21−278, SP4+ QLogic QLA4010−E−SP2, 4, 6, 7, 8 , QLogic LAN Only3 EMC N
v2.4.21−281, SP4+ v2.4.21−286, SP4+ v2.4.21−295, SP4+ QLA4010C−E−SP1, 2, 4, 5, 6 CLARiiON
v2.4.21−304, SP4+ v2.4.21−306, SP4+ v2.4.21−309 AX150i
5 SuSE SLES [32−Bit] 9 SP2+: v2.6.5−7.201, v2.6.5−7.202.7 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, LAN Only EMC N
18, 19, 24 ,
QLogic QLA4050−E−SP4, 8, 12, 13, 19 , QLogic CLARiiON
QLA4050C−E−SP4, 8, 12, 13, 19 AX150i
6 SuSE SLES [32−Bit] 9 SP2+: v2.6.5−7.201, v2.6.5−7.202.7 QLogic QLA4010−E−SP2, 4, 6, 8, 19 , QLogic LAN Only3 EMC N
QLA4010C−E−SP2, 4, 5, 6, 20 CLARiiON
AX150i
7 SuSE SLES [32−Bit] 9 SP2+: v2.6.5−7.201, v2.6.5−7.202.7; Generic NIC 10/10022, Generic NIC GbE22 LAN Only EMC N See3, 10
CLARiiON
SuSE SLES [32−Bit] 9: SP3 v2.6.5−7.244, SP3+ AX150i
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+
v2.6.5−7.276, SP3+ v2.6.5−7.282
8 SuSE SLES [32−Bit] 9: SP3 v2.6.5−7.244, SP3+ IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, LAN Only EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ 15, 16, 18, QLogic QLA4050−E−SP4, 8, 12, 13, 15 , QLogic CLARiiON
v2.6.5−7.276, SP3+ v2.6.5−7.282 QLA4050C−E−SP4, 8, 12, 13, 14 AX150i
9 SuSE SLES [32−Bit] 9: SP3 v2.6.5−7.244, SP3+ QLogic QLA4010−E−SP2, 4, 6, 8, 15 , QLogic LAN Only3 EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ QLA4010C−E−SP2, 4, 6, 8, 15 CLARiiON
v2.6.5−7.276, SP3+ v2.6.5−7.282 AX150i
1. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
2. Firmware Version 3.00.00.16
3. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
4. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
5. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
6. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
8. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
9. The following NICs are not supported: 3COM−3C996B
10. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
11. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
15. Driver Version 5.00.04 Driver is integrated into the kernel.
16. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. Driver Version 5.00.04−d5 Driver is integrated into the kernel.
18. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
20. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
21. Driver Version iSCSI Software Initiator 1.0−595 DS−M Connect ONLY interoperates with ControlCenter Host Agent, Symmetrix SDM Agent, Storage Agent for Symmetrix.
22. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
23. Driver Version iSCSI Software Initiator 1.0−595 Driver is integrated into the kernel.
24. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

SuSE SLES [AMD−64]

SuSE SLES [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [AMD−64] 8: SP4 v2.4.21−278, SP4+ Generic NIC 10/1003, Generic NIC GbE3, 4 LAN Only EMC N See1, 2
v2.4.21−281, SP4+ v2.4.21−286, SP4+ v2.4.21−295 CLARiiON
AX150i
2 SuSE SLES [AMD−64] 8: SP4 v2.4.21−278, SP4+ QLogic QLA4010−E−SP5, 7, 8, 10, 11 , QLogic LAN Only1 EMC N
v2.4.21−281, SP4+ v2.4.21−286, SP4+ v2.4.21−295 QLA4010C−E−SP5, 6, 7, 8, 9 CLARiiON
AX150i
3 SuSE SLES [AMD−64] 9 SP2+: v2.6.5−7.201, IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)10, 14, LAN Only EMC N
v2.6.5−7.202.7 16, 20, QLogic QLA4050−E−SP8, 10, 15, 16, 17 , QLogic CLARiiON
QLA4050C−E−SP8, 10, 15, 16, 17 AX150i
4 SuSE SLES [AMD−64] 9 SP2+: v2.6.5−7.201, QLogic QLA4010−E−SP5, 7, 8, 10, 16 , QLogic LAN Only1 EMC N
v2.6.5−7.202.7 QLA4010C−E−SP5, 7, 8, 9, 19 CLARiiON
AX150i
5 SuSE SLES [AMD−64] 9 SP2+: v2.6.5−7.201, Generic NIC 10/10018, Generic NIC GbE18 LAN Only EMC N See1, 2
v2.6.5−7.202.7; CLARiiON
AX150i
SuSE SLES [AMD−64] 9: SP3 v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267,
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282

11/02/2006 425 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

SuSE SLES [AMD−64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
6 SuSE SLES [AMD−64] 9: SP3 v2.6.5−7.244, SP3+ IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)10, 12, LAN Only EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, 13, 14, QLogic QLA4050−E−SP8, 10, 12, 15, 17 , QLogic CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLA4050C−E−SP8, 10, 15, 17, 21 AX150i
7 SuSE SLES [AMD−64] 9: SP3 v2.6.5−7.244, SP3+ QLogic QLA4010−E−SP5, 7, 8, 10, 12 , QLogic LAN Only1 EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, QLA4010C−E−SP5, 7, 8, 10, 12 CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 AX150i
1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. Driver Version iSCSI Initiator 3.6.2 Driver is integrated into the kernel.
4. The following NICs are not supported: 3COM−3C996B
5. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
6. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
7. Firmware Version 3.00.00.16
8. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
9. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
10. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
11. Driver Version 3.22 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. Driver Version 5.00.04 Driver is integrated into the kernel.
13. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
14. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
15. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
17. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
18. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
19. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
20. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
21. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.

SuSE SLES [EM64T]

SuSE SLES [EM64T]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 2, LAN Only EMC N
v2.6.5−7.202.7 3, 4, QLogic QLA4050−E−SP1, 4, 10, 11, 12 , QLogic CLARiiON
QLA4050C−E−SP1, 4, 10, 11, 12 AX150i
2 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, QLogic QLA4010−E−SP1, 4, 10, 14, 15 , QLogic LAN Only7 EMC N
v2.6.5−7.202.7 QLA4010C−E−SP10, 14, 15, 16, 17 CLARiiON
AX150i
3 SuSE SLES [EM64T] 9 SP2+: v2.6.5−7.201, Generic NIC 10/1009, Generic NIC GbE9 LAN Only EMC N See7, 8
v2.6.5−7.202.7; CLARiiON
AX150i
SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267,
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282
4 SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+ IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)2, 4, LAN Only EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, 5, 6, QLogic QLA4050−E−SP4, 5, 10, 11, 12 , QLogic CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 QLA4050C−E−SP4, 10, 11, 12, 13 AX150i
5 SuSE SLES [EM64T] 9: SP3 v2.6.5−7.244, SP3+ QLogic QLA4010−E−SP4, 5, 10, 14, 15 , QLogic LAN Only7 EMC N
v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, QLA4010C−E−SP4, 5, 10, 14, 15 CLARiiON
SP3+ v2.6.5−7.276, SP3+ v2.6.5−7.282 AX150i
1. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
3. Requires QLogic firmware version 2.00.00.07 available from the EMC−approved section of the QLogic website at http://www.qlogic.com
4. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
5. Driver Version 5.00.04 Driver is integrated into the kernel.
6. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
7. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
8. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
9. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.
10. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
11. Firmware Version 2.00.00.38 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
12. BIOS 1.08 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
13. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Driver is integrated into the kernel.
14. Firmware Version 3.00.00.16
15. BIOS 1.11 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
16. Driver Version 5.00.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com Requires SANsurfer for installation and configuration and is available for
download from the EMC−approved section of the QLogic website at http://www.qlogic.com
17. Requires QLogic firmware version 3.00.00.4 available from the EMC−approved section of the QLogic website at http://www.qlogic.com

SuSE SLES [IA64]

SuSE SLES [IA64]


Network Storage External
No. Operating System Host Bus Adapter Configuration Array Boot Comments
1 SuSE SLES [IA64] 9: SP1 v2.6.5−7.139, SP2+ v2.6.5−7.201, SP2+ v2.6.5−7.202.7, SP3 Generic NIC LAN Only EMC N See1, 2
v2.6.5−7.244, SP3+ v2.6.5−7.252, SP3+ v2.6.5−7.257, SP3+ v2.6.5−7.267, SP3+ v2.6.5−7.276, 10/1003, Generic CLARiiON
SP3+ v2.6.5−7.282 NIC GbE3 AX150i
1. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
2. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
3. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.

11/02/2006 426 CLARiiON AX150i


EMC CLARiiON AX100 Series Support Matrix

SuSE SLES [x86_64]

SuSE SLES [x86_64]


Network External
No. Operating System Host Bus Adapter Configuration Storage Array Boot Comments
1 SuSE SLES [x86_64] 10 Generic NIC 10/1007, 8, Generic NIC GbE7 LAN Only EMC CLARiiON AX150i N See5, 6
2 SuSE SLES [x86_64] 10 IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)1, 2, 3, 4 LAN Only EMC CLARiiON AX150i N

1. BIOS 1.04 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
2. Requires SANsurfer for installation and configuration and is available for download from the EMC−approved section of the QLogic website at http://www.qlogic.com
3. Driver Version 5.00.04−d5 Driver is integrated into the kernel.
4. Firmware Version 2.00.00.07 Available in the EMC−approved section of the QLogic website. http://www.qlogic.com
5. LAN support includes direct connect (layer 2), switched (layer 2), or routed (layer 3) networks.
6. The software initiator is part of the operating system and not an EMC software product. Please refer to the required release note "EMC Linux iSCSI Attach Release Notes", p/n
300−002−672, that can be found on EMC's Powerlink website in Support −> The Document Library −> Host Connectivity for the complete installation information.
7. Driver Version iSCSI Software Initiator 1.0−595 Driver is integrated into the kernel.
8. Driver Version iSCSI Software Initiator 4.0.188.18 Driver is integrated into the kernel.

iSCSI Clusters
Microsoft Windows 2003 [x64]
This table describes the support statements for iSCSI Clusters.

Microsoft Windows 2003 [x64]


Cluster Storage Max #
No. Operating System Software Host Bus Adapter Array Nodes Comments
1 Microsoft Windows 2003 [x64] Microsoft Generic NIC: 10/1006, GbE6 EMC HA: 8 See3, 4, 5
Enterprise: Edition, Edition R2 MSCS1, 2 CLARiiON
AX150i7
2 Microsoft Windows 2003 [x64] Microsoft QLogic: QLA4010−E−SP8, 9, QLA4010C−E−SP8, 9, QLA4050−E−SP, EMC HA: 4 See4, 5, 10
Enterprise: Edition, Edition R2 MSCS1, 2 QLA4050C−E−SP8, 9, 11, 12, 13, 14, 15, 16 , QLA4052C−E−SP8, 9, 11, 12, 13, 14, 15, 16 CLARiiON
AX150i7
1. Microsoft iSCSI Initiator required. Refer to Native iSCSI table for currently supported initiator version.
2. Booting from external storage for iSCSI clusters is not supported.
3. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.
4. Microsoft Dynamic Disks are not supported.
5. iSCSI based cluster configurations require Microsoft QFE 824354. Please contact Microsoft Product Support Services for this QFE.
6. Any Microsoft supported server/NIC for the listed operating system revision is supported.
7. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
8. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
9. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
10. Booting from external array is supported for iSCSI clusters with QLA4010 iSCSI HBAs. Refer to Native iSCSI table for supported BIOS versions.
11. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
12. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
13. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
14. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
15. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
16. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)

Microsoft Windows 2003 [x86]


This table describes the support statements for iSCSI Clusters.

Microsoft Windows 2003 [x86]


Cluster Storage Max #
No. Operating System Software Host Bus Adapter Array Nodes Comments
1 Microsoft Windows 2003 [x86] Microsoft Generic NIC: 10/10015, GbE15 EMC HA: 2 See4, 5, 16
Enterprise Edition MSCS1, 2 CLARiiON
AX150i3
2 Microsoft Windows 2003 [x86] Microsoft Generic NIC: 10/10015, GbE15 EMC HA: 8 See4, 5, 16
Enterprise Edition: R2, SP1 MSCS1, 2 CLARiiON
AX150i3
3 Microsoft Windows 2003 [x86] Microsoft IBM QLogic iSCSI Exp Card for BladeCenter (26K6487)8, 11; EMC HA: 4 See4, 5, 6
Enterprise: Edition, Edition R2, Edition MSCS1, 2 QLogic: QLA4010−E−SP8, 12, QLA4010C−E−SP8, 12, QLA4050−E−SP, CLARiiON
SP1; QLA4050C−E−SP7, 8, 9, 10, 11, 12, 13, 14 , QLA4052C−E−SP7, 8, 9, 10, 11, 12, 13, 14 AX150i3
Microsoft Windows 2003 [x86]
Storage: Server, Server SP1
1. Microsoft iSCSI Initiator required. Refer to Native iSCSI table for currently supported initiator version.
2. Booting from external storage for iSCSI clusters is not supported.
3. Maximum number of iSCSI initiators that can log into an iSCSI target port is 8
4. Microsoft Dynamic Disks are not supported.
5. iSCSI based cluster configurations require Microsoft QFE 824354. Please contact Microsoft Product Support Services for this QFE.
6. Booting from external array is supported for iSCSI clusters with QLA4010 iSCSI HBAs. Refer to Native iSCSI table for supported BIOS versions.
7. Configuration utility for QLogic iSCSI HBAs is QLogic SANsurfer available at http://www.qlogic.com
8. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator.
9. SPC−2 flag must be enabled for iSCSI Symmetrix configurations.
10. QLogic iSCSI HBAs require the Microsoft iSCSI Software Initiator 2.0 or 2.02 Service to be installed. The Service is required by Microsoft and is different from the full Microsoft iSCSI
Software Initiator. Refer to the EMC Host Connectivity guide for additional information on Windows iSCSI components and the Microsoft iSCSI Software Initiator usage.
11. Microsoft Initiator software version 2.0 and later automatically forces IQN's to lower−case. This may require array−side host access reconfiguration.
12. QLogic iSCSI HBAs are supported in any server listed in the ESM Fibre Channel tables that list support for the QLA2340 HBAs with the same operating system version listed here.
13. QLA4010 iSCSI boards booting from external storage require "Spanning Tree" features to be disabled on network switches used in the boot path.
14. Clustered hosts may access shared Symmetrix LUNs via iSCSI or Fibre Channel (iSCSI on one node, Fibre Channel on another.)
15. Any Microsoft supported server/NIC for the listed operating system revision is supported.
16. EMC provides troubleshooting and other technical notes for MSCS cluster solutions. Visit EMC Powerlink and download part number 300−003−012 for the MSCS
Troubleshooting/Technical Notes documentation.

11/02/2006 427 CLARiiON AX150i


User Installation Diagrams

Figure 1: A server with a single HBA connected to one port storage processor. Not highly available. Two single points of failure: HBA and SP. PowerPath in a Windows server tells you if that
one path has failed.

Figure 2: Two servers, each with a single HBA connected to the same SP through different ports. Two single points of failure for each server: HBA and SP. However, two servers have
access to the array. PowerPath on each Windows server only tells you if that one path has failed.
Servers can be clustered if they are running the same operating system.

11/02/2006 428 User Installation Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 3: One server with two HBAs connected to a port on each SP. Highly available configuration with one path to each SP. With PowerPath on a server, it can reach any virtual disk if one
SP fails or one HBA fails.

Figure 4: One server with four HBAs connected to an SP port on the two SPs. Highly available configuration with two paths to each SP (multipath). With PowerPath on a server, it can reach
any virtual disk if one SP fails or up to three HBAs fail.

Figure 5: Two servers with one HBA on each connected to an SP port on the two SPs. Not highly available. PowerPath on a server tells you if the path has failed.

Figure 6: Four servers with one HBA on each connected to an SP port on the two SPs. Not highly available. Each server has only one path to a storage processor. PowerPath on a server
tells you if one path has failed.

11/02/2006 429 User Installation Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 7: Two servers with two HBAs each connected to an SP port on the two SPs. Highly available configuration where each server has one path to each storage processor. With
PowerPath on a server, the server can reach any virtual disk if one SP fails or one HBA fails.
If the servers are running the same operating system, they can be clustered.

Figure 8: SAN with Brocade 3250VL2E and with four servers, (supporting up to six), each with one HBA. Each server can reach a port on either SP (see switch zoning
explanation below). The server cannot access the storage system if its HBA fails or if the switch port it connects to fails. With PowerPath on a server, the server can reach any
virtual disk if one SP fails.

If the servers are running the same operating system, they can be clustered.

Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade 3250VL2E, where ports 0 and 4 are for storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3,
5, 6, and 7.

11/02/2006 430 User Installation Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 9: Three servers with two HBAs each can reach one SP port on both SPs. Highly available configuration where each server has one path to each storage processor SP (see switch
zoning explanation below). With PowerPath on a server, the server can reach any virtual disk if one SP fails or one HBA fails.

If the servers are running the same operating system, they can be clustered.

Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2,
3, 5, 6, and 7.

Figure 10: SAN with two Brocade 3250VL2E switches and three servers (and supporting up to six). With two HBAs per server, each can reach a port on each SP. Highly available
configuration where each server has one path to each storage processor. With PowerPath on a server, the server can reach any virtual disk if one SP fails, or one HBA fails.

Note: You also can connect the remaining SP ports A1 and B1 to port 4 on each switch to create more high availability (each server will still be able to reach
virtual disks if a switch fails, because both SPs are connected to alternate switches). Also, if a server with a single HBA is connected to one of the switches, it
will have access to both SPs.

11/02/2006 431 User Installation Diagrams


EMC CLARiiON AX100 Support Matrix

If servers are running the same operating system, they can be clustered.

Figure 11: Three servers each with one HBA. Each server can reach an SP port on each SP (see switch zoning explanation below). With PowerPath on a server, the server can reach any
virtual disk if one SP fails. While each server has one path to each storage processor, the server cannot access the stoarge system if its HBA fails or if the switch port to which it connects
fails. This configuration allows you to connect the maximum 8 servers to an array.

If the servers are running the same operating system, they can be clustered.

Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3,
5, 6, and 7.

11/02/2006 432 User Installation Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 12: Three servers with two HBAs each can reach both SP ports on each SP. Highly available configuration, where each server has two paths to each storage processor. With
PowerPath on a server, the server can reach any virtual disk if one SP fails, a port on the SP fails, or one HBA fails. In addition, with redundant switches, each server will still be able to reach
virtual disks if a switch fails as both SPs are connected to alternate switches.

If any servers are running the same operating system, they can be clustered.

Figure 13: Three servers with two HBAs each can reach one SP port on both SPs. Highly available configuration where each server has one path to each storage system SP (see switch
zoning explanation below). With PowerPath on a server, the server can reach any virtual disk if one SP fails or one HBA fails.

An additional fourth server with two HBAs directly connected to each SP on the storage system. Because all available ports on the switch are occupied, this
configuration allows maximum server utilization.

If the servers are running the same operating system, they can be clustered.

Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage system ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2,
3, 5, 6, and 7.

11/02/2006 433 User Installation Diagrams


Professional Installation Diagrams

Figure 14: Three servers, each with one HBA. Each server can reach every SP port on each SP (see switch zoning explanation below), because of the inter−switch links on ports 6−7 and
5−4. With PowerPath on the server, the servers can reach any virtual disk if an SP fails.

While each server has multiple paths to each storage processor through the inter=switch links, the server cannot access the storage system if its HBA fails or if
the switch port to which it connects fails. This configuration allows you to connect the maximum 8 servers to an array.

If the servers are running the same operating system, they can be clustered.

Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3, 5, 6,
and 7.

11/02/2006 434 Professional Installation Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 15: One server with four HBAs. The server can reach every SP port on each SP (see switch zoning explanation below) through more than 1 path, because of the inter−switch links
on ports 7−6 and 5−4. With PowerPath on a server, the server can reach any virtual disk if a storage system SP fails or if fewer than four HBAs fail.

If the servers are running the same operating system, they can be clustered.

Preconfigured zoning allows each HBA to reach both storage processors. This illustration shows the Brocade VL2 E, where ports 0 and 4 are for the storage
system ports only. All other switch ports are for HBAs only. Storage ports connected to port 0 and port 4 can reach all HBAs connected to ports 1, 2, 3, 5, 6,
and 7.

11/02/2006 435 Professional Installation Diagrams


AX100i Configuration Diagrams
Management ports are not shown on any diagrams. The recommendation is to have management port connection on a differenct subnet. DATA paths should be on dedicated iSCSI networks.

Figure 16: Direct Attach, Single NIC/HBA to one subnet. 1Gb HBA or NIC must be used for direct attach.

Figure 17: Direct Attach, Multiple NIC/HBA to one array. NICs or HBAs must be on different subnets for proper routing. A server cannot connect to the same array using a mix of NICs and
HBAs.

Figure 18: Multiple servers to single storage array. Operating systems do not have to be the same. 1Gb HBA or NIC must be used for direct attach. NICs and HBAs, even if in different
servers, must be on different subnets for proper network routing.

11/02/2006 436 AX100i Configuration Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 19: When a switch or router is present, either 10/100/1000 NIC or 1Gb HBA can be used in the server. Operating systems do not have to be the same.

Figure 20: Dual HBAs or NICs. If multiple NICs are on the same subnet, the MS Advanced configuration setup must be utilized in order to take advantage of the additional NICs.

11/02/2006 437 AX100i Configuration Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 21: Two NICs or HBAs to separate routers/switched can be supported. However, if two NICs or HBAs are connected to separate switches or routers, they must be on different
subnets. The switch/router must be capable of 1Gb connection.

Figure 22: Single or multiple NICs/HBAs can be supported. A single NIC or HBA can be connected to up to 8 SP ports. The switch/router must be capable of 1Gb connection.

11/02/2006 438 AX100i Configuration Diagrams


EMC CLARiiON AX100 Support Matrix

Figure 23: Single or multiple HBAs can be supported. Multiple HBAs from one server can be logged into all ports simultaneously. Router must be capable of 1Gb connection.

Figure 24: Single or multiple NICs can be supported. Multiple NICs from one server can log into all ports, but only 1 NIC per server can be longed into a port at any given time. Router must
be capable of 1 Gb connection.

11/02/2006 439 AX100i Configuration Diagrams