Você está na página 1de 32

Area = 676163m² 67.

616 ha
Long. Dist.= 110 m
Long. Dist.= 122 m
Long. Dist.= 61 m
750 m
4.31

48 10 8 7 4 2 110

11 9 6 5 3 1 110
901.55 m
110 4.31
8 880
c 21.55 36 10 8 7 4 2 110
c/c 4.31

11 9 6 5 3 1 110

4.31

24 10 8 7 4 2 110

11 9 6 5 3 1 110

4.31

12 10 8 6 4 2 110

11 9 7 5 3 1 110

4.31 901.6
7 122 122 3.7 122 122 3.7 122 122 3.7
750

Area efectiva bajo riego = 64.4


750.0
122 61
6 732 Ancho efectivo = 732
c 18 Largo efectivo = 880
c_p 7
c/c 3.6667
m

has
DATOS METEOROLOGICOS

Pais : Perú
Estac.Meteorol. : Miraflores PECHP
Altitud : 30 msnm
Cordenadas : 7,085 LS 78.28 LW

Precipit. Prec. efec T° max. T° min. T° media H° Relat.. V.Viento Ins. Horas ETo Prom
N° Mes
(mm/mes) (mm/mes) (°C) (°C) (°C) (%) (m/s) (Hrs) (mm/dia) .

1° Ene. 81.00 71.00 21.30 7.60 14.45 81 0.11 4.60 5.80


2° Feb. 96.00 81.00 21.30 6.90 14.10 82 0.17 4.40 5.71
3° Mar. 104.00 87.00 20.90 7.00 13.95 86 0.11 4.00 5.78
4° Abr. 83.00 72.00 21.30 6.60 13.95 85 0.07 4.50 5.45
5° May. 33.00 31.00 21.70 4.40 13.05 86 0.11 5.60 4.79
6° Jun. 9.00 9.00 21.80 3.50 12.65 80 0.24 5.80 4.02
7° Jul. 6.00 6.00 21.60 3.10 12.35 77 0.24 6.50 3.99
8° Ago. 10.00 10.00 21.90 3.90 12.90 75 0.18 5.90 4.20
9° Set. 31.00 29.00 22.00 4.90 13.45 77 0.14 4.80 4.72
10° Oct. 98.00 83.00 21.60 6.80 14.20 79 0.11 5.00 4.85
11° Nov. 64.00 57.00 21.70 6.00 13.85 80 0.11 6.00 4.98
12° Dic. 72.00 64.00 22.00 6.20 14.10 80 0.11 5.30 5.40
Prom. 687.00 600.00 59.69
Precipitación efectiva según el método USBR
ETo : Método Penman M.

UNALM-EPG-IRH _ Raúl Yancce Vargas email : yancc_@hotmail.com - yanc_@latinmail.com


CALCULO DE DEMANDA DE AGUA DEL CULTIVO
DATOS GENERALES:

Pais : Perú
Estac. Meteorol. : Cajamarca
Altitud : 2620,0 msnm
Cordenadas : 7,085 LS, 78,28 LW
Cultivo : Aji paprika
Area (has) : 1 Método : Penman - Monteith (mod. FAO)

No DESCRIPCION ECUACION Ene. Feb. Mar. Abr. May. Jun. Jul. Ago. Set. Oct. Nov. Dic. Prom.

1° Dias 31 28 31 30 31 30 31 31 30 31 30 31

2° Coef. Cultivo (Kc) =( gráfico Curva Kc ) 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60
3° ETo(mm/día) =Calc. Métodos 5.80 5.71 5.78 5.45 4.79 4.02 3.99 4.20 4.72 4.85 4.98 5.40 4.97
4° Prec. Est.(mm/mes) Estac. Meteorlogica 81.00 96.00 104.00 83.00 33.00 9.00 6.00 10.00 31.00 98.00 64.00 72.00
5° Prec. Efect.(mm/mes) =Cálculo 71.00 81.00 87.00 72.00 31.00 9.00 6.00 10.00 29.00 83.00 57.00 64.00
6° ETc(mm/día) =Eto * Kc 3.48 3.43 3.47 3.27 2.87 2.41 2.39 2.52 2.83 2.91 2.99 3.24
7° ETc(mm/mes) =Eto * Kc*días 107.88 95.93 107.51 98.10 89.09 72.36 74.21 78.12 84.96 90.21 89.64 100.44
8° Dem. neta(mm/mes/ha) 36.88 14.93 20.51 26.10 58.09 63.36 68.21 68.12 55.96 7.21 32.64 36.44 488.45
9° Dem. neta(mm/día) 1.19 0.53 0.66 0.87 1.87 2.11 2.20 2.20 1.87 0.23 1.09 1.18 16.00
10° Mod.neto(l/s/Ha) =D.N./(dias*8,64) 0.14 0.06 0.08 0.10 0.22 0.24 0.25 0.25 0.22 0.03 0.13 0.14
11° Mod.neto(l/s/area total) 0.14 0.06 0.08 0.10 0.22 0.24 0.25 0.25 0.22 0.03 0.13 0.14 1.85

UNALM-EPG-IRH _ Raúl Yancce Vargas email : yancc_@hotmail.com - yanc_@latinmail.com


DISEÑO DE RIEGO POR GOTEO
DATOS GENERALES :

CULTIVO = ALCACHOFA
Per. Vegetativo = 06 meses
Prof. Raices = 100 cm = 1 m. = 1000 mm
% H.D. = 40 % = 0.4
% agotamiento = 50 % = 0.5
ETc = 3.48 mm/día

SUELO / TERRENO
Area 749.83 = 676009 m² = 67.60 Has
901.55 =
Pendiente = 1.43 %
Textura = Arenoso
Contenido de humedad a :
Capac. Campo : (H°CC) = 8.90
Punto marchitez : (H°PM) = 3.20
Dens. Aparente : (ρs) = 1.54 gr/cm²
Dens. Agua : (ρa) = 1.00 gr/cm²

SISTEMA DE RIEGO
Método = Goteo
Efic. Aplicación = 90 %
Modelo de Emisor = Gotero KATIF
Caudal nominal : (qa) = 2.30 lt/Hr
Diam. Exterior : (Øe) = 16 mm
Diam. interior : (Øi) = 14 mm
Coef. Variabilidad : (C.V.) = 5 % = 0.05
Coef. Uniformidad : (C.U.) = 90 % = 0.9
Espac. Laterales = 1.50 m. = 1.504 m Corregido
Espac. Goteros = 0.40 m.
Espac. Plantas = 0.40 m.

Long. Laterales = 59.98 m. (Se deja 0.50 m en los extremos; para salida de purga)
Long. Distribuidor = 109.01 m. (Se deja 1.00 m en los extremos, para caja de válvulas: ingreso y limpia)
Largo SUR = 121.96 m
Ancho SUR = 110.01 m.
Area SUR = 13415.81 m²

Calles 1 7 3 3.7 749.83 Ancho 750


Calles 1 4.3 4 4.3 901.55 Largo 902

Nº de Sub Unidades de Riego = 47.70 ≈ 48.00 SUR Sin las calles


EQUIVALENCIAS DE Ø
(mm) Pulg.
20 1/2"
25 3/4"
32 1"
40 1 1/4"
50 1 1/2"
63 2"
75 2 1/2"
90 3"
110 4"
125 5"
140 6"
Copyright © -2001 ELRIEGO.COM

lvulas: ingreso y limpia)


DISEÑO AGRONOMICO

IDM Descripción Simb. Formula Valor Und. Valor Und Observaciones

1° Cálculo de la lámina de riego corregida


Capac. retentiva del agua en el suelo Lng = ((HCC-HPM)/100)*(Ds/Da)*prof.*%HD 35.11 mm
Diámetro mojado Dm = (espac. gotero / 0,8) 0.50 m
% Area Mojada %AM = ( Area mojada / Area total ) 100 33.33 %
Lámina neta de riego Ln = ( Lng * %AM )/100 11.704 mm 117.04 m³/Ha
2º Frecuencia de Riego (Fr)
Frecuencia de riego Fr = Ln / ETc 10.1 dias Interv. días entre riegos
Frecuencia de riego Fr = Ln / ETc 3.4 dias => 3.0 Asumido
3º Eficiencia de Riego (Er)
Eficiencia de riego Er = CU * ( 1 - K ) 0.8550
4º Caudal del Sistema/ha
Volum. Aplicación V= (ETc / Er) * 10 40.70 m³/Ha
N° de Goteros por lateral NG= ((Long.Later) / (Espac. de goteros)+1) 150.94 Por lado
N° de laterales Nl = ((long.Distri-1) / (Espac. Lateral)+1) 72.79
Caudal del lateral QL = (NL)*q got 347.17 lt/hr 0.0964 l/s
Caudal SUR Qsur = (Numero Lateral * q lateral ) 50542.11 lt/hr 50.542 m³/Hr/Ha
5º Tiempo de Riego (T) 14.039 lt/s/Ha
Tiempo de rieg / Ha Tr = Volumen / Caudal 0.805 Hr
CALCULO DE LA DEMANDA DE AGUA DEL SISTEMA:
IDM Descripción Simb. Formula Valor Und. Valor Und Observaciones

Volumen a aplicar Va = ( ETc / Er ) 4.07 mm/día 0.4711 lt/s/Ha


40.702 m³/Ha
6º Caudal del Sistema (Aproximación del Caudal Preliminar)
Caudal ( 7 Hrs ) Q(7) = 2,78 * A * D / F *(Hr/día) 36.42 lt/s
Caudal ( 12 Hrs ) Q(12) = 2,78 * A * D / F *(Hr/día) 21.25 lt/s
Caudal ( 16 Hrs ) Q(16) = 2,78 * A * D / F *(Hr/día) 15.94 lt/s
Caudal ( 24 Hrs ) Q(24) = 2,78 * A * D / F *(Hr/día) 10.62 lt/s

Distribución preliminar de las áreas de la Sub unidad de riego


Area de la Sub Unidad de Riego Asur = Ancho x Largo 13415.81 m² 1.3416 Has
Caudal de la Sub Unid. Riego Qsur = ( Q/Ha ) * A sur ) 18.84 lt/s
N° de Sub Unid. Regados simult. N° sur= ( Q(12) / Qsur ) 1.13 Asum = 2 SUR
Caudal del Sistema /SUR QS = ( Qsur * N° sur ) 37.67 lt/s
Corregiendo el Tiempo de riego con respecto al Caudal del sistema
Tiempo de riego corregido Tr = (Va / Qs) * (Asur / 3.6 ) 0.40 Hrs
Nº de Sub Unidades de Riego 48.00 Und
más 10 min. Por tiempo de manipulación 0.65 Hrs + 0.25
Tiempo de riego de todo el sistema(48 sub unidades de riego) = 31.33 Hrs 3 dias

MANEJO DE LAS SUB UNIDADES DE RIEGO


T Unudades de riego
1° 1; 2
2° 3; 4
IDM Descripción Simb. Formula Valor Und. Valor Und Observaciones

3° 5; 6
4° 7; 8
5° 9; 10
6° 11; 12
...

...

24° 47; 48

CALCULO DEL COEFICIENTE DE UNIFORMIDAD


1
q a 0 .55
q=0 . 57∗h0 .55 ⇒h=( )
0 . 57

Presión media de trabajo del gotero ha = 12.63 m.

1 . 27∗CV qmin CU∗q a


CU =(1−
√e
)∗
qa
⇒ q min=
(1− [
1. 27∗CV
√e
) ]
Nº goteros /planta = 2 und.
Caudal mínimo de trabajo q min = 2.17 lt/Hr
Presión mínima de trabajo h min = (q min / 0,57) ^(1/0,55) 11.34 m.

CALCULO DE LA PERDIDA DE CARGA ADMISIBLE DEL SISTEMA Tabla: M= 2.50 Pag. 415 : F. Pizarro.
Pérdida de carga Admisible en SUR ∆H = M*( ha - h min ) 3.23 m. Max.Pres.a perd. SUR
IDM Descripción Simb. Formula Valor Und. Valor Und Observaciones

CALCULO DE LA EFICIENCIA DE RIEGO La pérdida por percolación profunda se asume un 8% (prueba con lisímetro)
Eficiencia de riego Er = CU * ( 1 - %Pp ) 0.83

∆H = ∆Hl + ∆Ht
En terrenos planos se considera
∆Hl = ∆Ht = ∆H/2

N° = 24 * K * Fr / Tr 80.4665
CHEQUEOS

0.00
10.09

473.8

11250
COSTO UNITARIO ANUAL DE ENERGIA

LUGAR : Tacna
CULTIVO : Alcachofa
AREA TOTAL : 67.60 has
Ef. BOMBA/MOTOR : 85%
CAUDAL BOMBA : 135.61 (m³/hr) 37.67 (l/s)
CONSUMO : 11.50 (hp-hr/galón
PRECIO : 2.00 ($/galón)
DIESEL 90 (HP- hr/gl) :

Area
DESCRIPCION Ene. Feb. Mar. Abr. May. Jun. Jul. Ago. Set. Oct. Nov. Dic. Prom.
(Ha)

1° Dias del mes 31.00 28.00 31.00 30.00 31.00 30.00 31.00 31.00 30.00 31.00 30.00 31.00
2° Coef. Cultivo (Kc) = ( gráfico Curva Kc ) 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60 0.60
3° ETo(mm/día) = Calc. Métodos 5.80 5.71 5.78 5.45 4.79 4.02 3.99 4.20 4.72 4.85 4.98 5.40 4.97
4° ETc(mm/día) = Eto * Kc 3.48 3.43 3.47 3.27 2.87 2.41 2.39 2.52 2.83 2.91 2.99 3.24
5° ETc(mm/mes) = Eto * Kc* Nº dias 107.88 95.93 107.51 98.10 89.09 72.36 74.21 78.12 84.96 90.21 89.64 100.44
6° D-Neta(m³/mes/Ha) = Etc*10 1078.80 959.28 1075.08 981.00 890.94 723.60 742.14 781.20 849.60 902.10 896.40 1004.40
7° D-Bruta(m³/mes/Ha) = D-Neto/efic.Bomba 1269.18 1128.56 1264.80 1154.12 1048.16 851.29 873.11 919.06 999.53 1061.29 1054.59 1181.65
8° D-Bruta(m³/mes/area) = 85797.50 76292.02 85501.65 78019.42 70856.90 57548.27 59022.76 62129.23 67569.11 71744.46 71291.14 79880.43 865652.89
9° T.O.B. (hr/mes) = D-Bruta / Q-Bomba 632.67 562.57 630.48 575.31 522.49 424.36 435.23 458.14 498.25 529.04 525.70 589.03 6383.27
10° T.O.B (Hr/diaria) = 20.41 20.09 20.34 19.18 16.85 14.15 14.04 14.78 16.61 17.07 17.52 19.00 210.03

Tiempo de operaciòn de la Bomba = 6383.27 Hr/año 4380


Costo Unitario Anual de Potencia = 1110.13 $/HP

D.N : Demanda Neta (mm/mes) D.N = E.T.C * DIAS


D.B : Demanda Bruta (m3/ha) D.B = D.N * 10 /Efr
VOL.T : Volumen Total (m3) VOL.T = D.B * Has
T.O.B : Tiempo de Operación (Hr/mes) T.O.B = V.T / Qb
1- Cálculo de la Pérdida de Carga por metro de tubería (Hf), mediante form. Hazzen Williams
1. 852
Hf (m/m)=K ( ) ∗( D 1 )∗F (n )
Q
C 4 . 87

K= 1.21E+10
C= 150 Coef. Fricc.para PVC
D= Ø Tubería
F(n) = 1 Correcc. Por el Nº de salidas (F=1, cuando no hay salidas)
i= Ø Candidato de Tuberìa (mm)
j= Caudal en el tramo analizado (l/s)

Diam. Ø Perdida de carga (Hf) : m/m


(mm) ↓ Linea 1,j Linea 2,j Linea 3,j Linea 4,j Linea 5,j Linea 6,j Linea 7,j Linea 8,j Linea 9,j Linea 10,j
Ql (l/s)→ 15 10
i,1 76.2 0.11632 0.05490 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
i,2 102 0.02811 0.01327 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
i,3 147 0.00474 0.00224 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
i,4 196 0.00117 0.00055 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
i,5 245 0.00039 0.00019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
SELECCIÓN TECNICA - ECONOMICA DE TUBERIAS PRINCIPALES

La selección se realiza teniendo en cuenta los costos fijos de la tubería en función del Ø y los costos de operación (energía)
necesarios para vencer las pérdidas por fricción para 100 m.

A- COSTOS FIJOS ANUALES


1° Cálculo del Factor de Recuperación del Capital (FRC):
n
i∗( 1+ i )
FRC=
( 1+i )n−1
Donde:
i = Tasa de Interes anual (decimas) = 18%
n = Vida útil de la Tubería (años) = 10
F.R.C. = 0.223

2° Costo Anualizadas de Tuberías Candidatos / 100m


Para llevar el Costo Unitario de la Tubería a Costo Unitario anual, se debe multiplicar el C.U. por el FRC

Material = PVC Clase = 7.5 Q= 37.67 l/s

Diametro Candidatos (Pulg) 2 3 4 6 8 10 12


Øi=(mm) 56.4 84.1 108.4 152.4 203.2 254.0 304.8
Costo Unitario ( $/100m) 76 114 152.00 409.00 748.00 1170.00 1860.00
C. U. Anualizado ( $/100m) 16.91 25.37 33.82 91.01 166.44 260.34 413.88
Velocidad (m/s) 15.08 6.78 4.08 2.07 1.16 0.74 0.52

B- COSTOS DE OPERACIÓN ANUALES

1° Pérdida energía por fricción en 100 metros de tubería (Hf)


1 .852
Hf ( 100 m / m )= J∗ (100L m ) J =K ( QC ) ∗ ( D1 ) 4 .87

K = 1210000000000
C = 150.00 Coef. Fricc.para PVC
Q = 37.67 l/s 135.61 M3/Hr

Area Total 67.60 has


ETc : prom. Anual (mm/día) 3.48
Volumen anual a bombear (m³) 865652.89
Ef. Bomba/motor = 0.55
Coef. Para HP o Kw 76.00
Caudal bomba = 135.61 (m³/hr)
Consumo = 11.50 (hp-hr/galón
Precio = 2.00 ($/galón)
Horas de Operación anual = 6383.27

Diámetro Candidatos (Pulg) 2 3 4 6 8 10 12


Øi=(mm) 56.4 84.1 108.4 152.4 203.2 254.0 304.8
Pérdida carga (Hf) : 100m/m 277.130 39.596 11.503 2.189 0.539 0.182 0.075

2° Costo Unitario de la Potencia (CU)

CU ($ Hp−año )=
( precio( $ galón )∗Hrs . AnualesOperac .
Consum . Pr omed .( Hp− Hr/ galon) )
CU ($/hp-año) 1110.13

3° Cálculo de la Potencia (hp ó kw) necesario para vencer las pérdidas por fricción (L=100m)

De la ecuación : Potencia ( hp )=( Q∗Hf )/ Coef .∗Ef


Donde:
Coef. Para hp ó kw = 76
Ef : Efic. bomba y motor (%) = 55%
Diametro Candidatos (Pulg) 2 3 4 6 8 10 12
Øi=(mm) 56.4 84.1 108.4 152.4 203.2 254.0 304.8
Potencia (hp ó kw) 249.75 35.68 10.37 1.97 0.49 0.16 0.07

4° Costo anual de los hp requeridos para vencer las pérdidas por fricción (L=100m)

De la ecuación : Costo. Anual .($/ año )=CU ($/ hp−año)∗Potencia(hp)


Diametro Candidatos (Pulg) 2 3 4 6 8 10 12
Øi=(mm) 56.4 84.1 108.4 152.4 203.2 254.0 304.8
Costo bombeo ($/100m) 277255.53 39614.39 11508.45 2190.14 539.54 182.00 74.90

C- SUMATORIA DE LOS COSTOS FIJOS Y DE BOMBEO ANUALIZADO

Diametro Candidatos
(Pulg) 2 3 4 6 8 10 12
Costo anualizado ( $/100m) 16.91 25.37 33.82 91.01 166.44 260.34 413.88
Costo de bombeo ( $/100m) 277255.53 39614.39 11508.45 2190.14 539.54 182.00 74.90
Costo fijo + C. bombeo ($/100m) 277272.45 39639.76 11542.27 2281.15 705.98 442.34 488.77
Costo ($/100m)

SELECCIÓN TECNICO ECONOMICO


300000
277272.4

250000

200000

150000

100000

50000
39639.8

11542.3
0 2281.2 706.0 442.3 488.8
0 2 4 6 8 10 12 14

Costo anualizado
Diametros candidatos (pulg) Costo de bombeo
Costo fijo + C. bombeo
SISTEMA DE RIEGO A PRESION

A) DISEÑO DE TUBERIA LATERAL

Datos de diseño :
Caudal gotero: qa (l/h) 2.30 l/h 0.0006389 l/s
Esp. Goteros :Se ( m) 0.40 m.
Long. Lateral: l ( m) 59.98 m.
Caudal lateral ( l/s) 0.096 l/s
Coef. Para tub. PVC : C 130 =+(1.21*10^10)*((F$19/F$11)^1.8552)*(E25^-4.87)
Pérd. caraga admisible: ∆Hl= 3.23 m. Dato de diseño Agronómico =(((Q/1000)*(Long)^(0.54)*1/0.2788*1/C*1/(D/1000)^(2.63)))^(1/0.54)
Presión mínima de trab.: ha = 12.63 m. Dato de diseño Agronómico

Cálculos previos:
Pendiente ( i ) = 0.0026673 Lprom= 340.00 Hprom= 5.00
m (F. Hanzen-Williams) 1.8552 1 . 8552
Q
Nº goteros :n
Caudal lateral ( l/s)
F ( n, lo=Se)
151 goteros
0.096 l/s
0.3535574
9.64E-05 m3/seg Hf ( m /m )= J '* F∗L J (m / m)=1. 21∗10 ∗ C
10
( ) ∗
( D1 )4 . 87

fe (m) de tabla =18.91*d^(-1.87) fe = 0.24137 1.87842 Condición = hm-hn < ∆H = 3.23 m

PARA TRAMO CON PENDIENTE POSITIVA: 0.0027

Nº Diametro Candidatos Long. Desnivel fe J J' hf hn hm ∆h Veloc.


Observaciones
Øe (mm) Øi (mm) (m) (m) (m) (m) (m) (m) (m) (m) hm-hn (m/s)
1° 12.5 10.3 59.98 0.00 0.24 0.2208 0.354 7.51 10.63 18.14 7.51 1.16 : (CORREGIR) No existe p. disponible
2° 16 13.2 59.98 0.00 0.15 0.0660 0.091 1.93 12.12 14.05 1.93 0.70 : (OK) Existe presiòn disponible
3° 20 16 59.98 0.00 0.11 0.0259 0.033 0.69 12.45 13.14 0.69 0.48 : (OK) Existe presiòn disponible Elegimos este diametro porque hay men
4° 25 21.8 59.98 0.00 0.06 0.0057 0.007 0.14 12.60 12.74 0.14 0.26 : (OK) Existe presiòn disponible
5° 32 28 59.98 0.00 0.04 0.0017 0.002 0.04 12.62 12.66 0.04 0.16 : (OK) Existe presiòn disponible
NOTA: En este caso se considera solamente el caso crítico para pendiente positiva.

Diametro elegido
3° 20 16 59.9775 0.0015998 0.11 0.03 0.033 0.69 12.45 13.14 0.69 0.48 : (OK) Existe presiòn disponible
Pérd. carga admisible para el Lateral: ∆Hl= 0.69 m.
Presión mínima en la entrada del lateral : Hm = 13.14 m.

SISTEMA DE RIEGO A PRESION

B) DISEÑO DE TUBERIA TERCIARIA:


(Distribuidor)
Datos de diseño :
1 2 3 4
Caudal lateral : ql (l/s) 0.096 l/s 347.2 l/h 0.2588
n
Esp. laterales :Sl ( m) 1.5 m.
Long. distribuidor: l ( m) 109.01 m.
Coef. Para tub. PVC : C 150 Q (l/h)

Tol. Perd. carga: ∆Hl= 0.69 m. Lateral

Secundaria
P. Entrada lateral: hm = 13.14 m.
Se
Terciaria

Cálculos previos:
Pendiente ( i ) = 0.0147 Lprom= 340.00 Hprom= 5.00
m (F. Hanzen-Williams) 1.8552
Nº salidas :n 73
Caudal Distribuidor ( l/s) 14.04 l/s 50542.1 l/h Factor Corrección = 1.342 Caud.Correg= 18.84 lts/seg
F ( n, lo=Se) 0.357
fe (m) de tabla =18.91*d^(-1.87) Condición = Hm-Hn < ∆H = 2.43 m
Espac.Later.Correg. = 1.50 m

PARA TRAMO CON PENDIENTE POSITIVA: 0.0147

Tramo Diametro Candidatos Long. Desnivel Caudal fe J J' hf Hn Hm ∆h Veloc.


Observaciones
Observaciones
de a Øe (mm) Øi (mm) (m) (m) ( l/s ) (m) (m) (m) (m) (m) (m) hm-hn (m/s)
0° 1° 88.5 84.1 1.00 0.0147 18.84 0.005 0.11 0.109 0.0390 15.10 15.15 0.05 3.39
1° 2° 88.5 84.1 1.50 0.0221 18.58 0.005 0.11 0.107 0.0572 15.04 15.12 0.08 3.34
2° 3° 88.5 84.1 1.50 0.0221 18.32 0.005 0.10 0.105 0.0563 14.99 15.07 0.08 3.30
3° 4° 88.5 84.1 1.50 0.0221 18.06 0.005 0.10 0.102 0.0548 14.94 15.01 0.08 3.25
4° 5° 88.5 84.1 1.50 0.0221 17.80 0.005 0.10 0.099 0.0533 14.89 14.96 0.08 3.20
5° 6° 88.5 84.1 1.50 0.0221 17.54 0.005 0.10 0.097 0.0519 14.84 14.91 0.07 3.16
6° 7° 88.5 84.1 1.50 0.0221 17.28 0.005 0.09 0.094 0.0505 14.79 14.86 0.07 3.11
7° 8° 88.5 84.1 1.50 0.0221 17.02 0.005 0.09 0.091 0.0491 14.74 14.82 0.07 3.06
8° 9° 88.5 84.1 1.50 0.0221 16.77 0.005 0.09 0.089 0.0477 14.70 14.77 0.07 3.02
9° 10° 88.5 84.1 1.50 0.0221 16.51 0.005 0.09 0.086 0.0464 14.65 14.72 0.07 2.97
10° 11° 88.5 84.1 1.50 0.0221 16.25 0.005 0.08 0.084 0.0450 14.61 14.68 0.07 2.92
11° 12° 88.5 84.1 1.50 0.0221 15.99 0.005 0.08 0.081 0.0437 14.57 14.63 0.07 2.88
12° 13° 88.5 84.1 1.50 0.0221 15.73 0.005 0.08 0.079 0.0424 14.53 14.59 0.06 2.83
13° 14° 88.5 84.1 1.50 0.0221 15.47 0.005 0.08 0.077 0.0411 14.48 14.55 0.06 2.79
14° 15° 88.5 84.1 1.50 0.0221 15.21 0.005 0.07 0.074 0.0399 14.44 14.51 0.06 2.74
15° 16° 88.5 84.1 1.50 0.0221 14.95 0.005 0.07 0.072 0.0386 14.41 14.47 0.06 2.69
16° 17° 88.5 84.1 1.50 0.0221 14.70 0.005 0.07 0.070 0.0374 14.37 14.43 0.06 2.65
17° 18° 88.5 84.1 1.50 0.0221 14.44 0.005 0.07 0.067 0.0362 14.33 14.39 0.06 2.60
18° 19° 88.5 84.1 1.50 0.0221 14.18 0.005 0.06 0.065 0.0350 14.29 14.35 0.06 2.55
19° 20° 88.5 84.1 1.50 0.0221 13.92 0.005 0.06 0.063 0.0338 14.26 14.31 0.06 2.51
20° 21° 88.5 84.1 1.50 0.0221 13.66 0.005 0.06 0.061 0.0326 14.22 14.28 0.05 2.46
21° 22° 88.5 84.1 1.50 0.0221 13.40 0.005 0.06 0.059 0.0315 14.19 14.24 0.05 2.41
22° 23° 88.5 84.1 1.50 0.0221 13.14 0.005 0.06 0.057 0.0304 14.16 14.21 0.05 2.37
23° 24° 88.5 84.1 1.50 0.0221 12.88 0.005 0.05 0.055 0.0293 14.12 14.18 0.05 2.32
24° 25° 88.5 84.1 1.50 0.0221 12.62 0.005 0.05 0.052 0.0282 14.09 14.14 0.05 2.27
25° 26° 88.5 84.1 1.50 0.0221 12.37 0.005 0.05 0.051 0.0271 14.06 14.11 0.05 2.23
26° 27° 88.5 84.1 1.50 0.0221 12.11 0.005 0.05 0.049 0.0261 14.03 14.08 0.05 2.18
27° 28° 88.5 84.1 1.50 0.0221 11.85 0.005 0.05 0.047 0.0251 14.00 14.05 0.05 2.13
28° 29° 88.5 84.1 1.50 0.0221 11.59 0.005 0.04 0.045 0.0241 13.97 14.02 0.05 2.09
29° 30° 88.5 84.1 1.50 0.0221 11.33 0.005 0.04 0.043 0.0231 13.95 13.99 0.05 2.04
30° 31° 88.5 84.1 1.50 0.0221 11.07 0.005 0.04 0.041 0.0221 13.92 13.96 0.04 1.99
31° 32° 88.5 84.1 1.50 0.0221 10.81 0.005 0.04 0.039 0.0212 13.89 13.94 0.04 1.95
32° 33° 88.5 84.1 1.50 0.0221 10.55 0.005 0.04 0.038 0.0202 13.87 13.91 0.04 1.90
33° 34° 88.5 84.1 1.50 0.0221 10.30 0.005 0.04 0.036 0.0193 13.84 13.88 0.04 1.85
34° 35° 88.5 84.1 1.50 0.0221 10.04 0.005 0.03 0.034 0.0184 13.82 13.86 0.04 1.81
35° 36° 73 69.4 1.50 0.0221 9.78 0.007 0.08 0.084 0.0450 13.77 13.83 0.07 2.59
36° 37° 73 69.4 1.50 0.0221 9.52 0.007 0.08 0.080 0.0428 13.73 13.79 0.06 2.52
37° 38° 73 69.4 1.50 0.0221 9.26 0.007 0.07 0.076 0.0407 13.69 13.75 0.06 2.45
38° 39° 73 69.4 1.50 0.0221 9.00 0.007 0.07 0.072 0.0386 13.65 13.71 0.06 2.38
39° 40° 73 69.4 1.50 0.0221 8.74 0.007 0.07 0.068 0.0365 13.61 13.67 0.06 2.31
40° 41° 73 69.4 1.50 0.0221 8.48 0.007 0.06 0.064 0.0346 13.57 13.63 0.06 2.24
41° 42° 73 69.4 1.50 0.0221 8.23 0.007 0.06 0.061 0.0326 13.54 13.59 0.05 2.17
42° 43° 73 69.4 1.50 0.0221 7.97 0.007 0.06 0.057 0.0308 13.51 13.56 0.05 2.11
43° 44° 73 69.4 1.50 0.0221 7.71 0.007 0.05 0.054 0.0289 13.47 13.53 0.05 2.04
44° 45° 73 69.4 1.50 0.0221 7.45 0.007 0.05 0.051 0.0272 13.44 13.49 0.05 1.97
45° 46° 73 69.4 1.50 0.0221 7.19 0.007 0.05 0.047 0.0254 13.41 13.46 0.05 1.90
46° 47° 73 69.4 1.50 0.0221 6.93 0.007 0.04 0.044 0.0238 13.39 13.43 0.05 1.83
47° 48° 73 69.4 1.50 0.0221 6.67 0.007 0.04 0.041 0.0221 13.36 13.40 0.04 1.76
48° 49° 73 69.4 1.50 0.0221 6.41 0.007 0.04 0.038 0.0206 13.33 13.38 0.04 1.70
49° 50° 73 69.4 1.50 0.0221 6.16 0.007 0.03 0.035 0.0191 13.31 13.35 0.04 1.63
50° 51° 73 69.4 1.50 0.0221 5.90 0.007 0.03 0.033 0.0176 13.29 13.33 0.04 1.56
51° 52° 73 69.4 1.50 0.0221 5.64 0.007 0.03 0.030 0.0162 13.26 13.30 0.04 1.49
52° 53° 73 69.4 1.50 0.0221 5.38 0.007 0.03 0.028 0.0148 13.24 13.28 0.04 1.42
53° 54° 73 69.4 1.50 0.0221 5.12 0.007 0.02 0.025 0.0135 13.22 13.26 0.04 1.35
54° 55° 73 69.4 1.50 0.0221 4.86 0.007 0.02 0.023 0.0123 13.20 13.24 0.03 1.29
55° 56° 73 69.4 1.50 0.0221 4.60 0.007 0.02 0.021 0.0111 13.18 13.22 0.03 1.22
56° 57° 73 69.4 1.50 0.0221 4.34 0.007 0.02 0.019 0.0100 13.16 13.20 0.03 1.15
57° 58° 73 69.4 1.50 0.0221 4.09 0.007 0.02 0.017 0.0089 13.15 13.18 0.03 1.08
58° 59° 73 69.4 1.50 0.0221 3.83 0.007 0.01 0.015 0.0079 13.13 13.16 0.03 1.01
59° 60° 73 69.4 1.50 0.0221 3.57 0.007 0.01 0.013 0.0069 13.13 13.16 0.03 0.94
60° 61° 73 69.4 1.50 0.0221 3.31 0.007 0.01 0.011 0.0060 13.13 13.16 0.03 0.87
61° 62° 60 56.4 1.50 0.0221 3.05 0.010 0.03 0.027 0.0143 13.13 13.16 0.04 1.22
62° 63° 60 56.4 1.50 0.0221 2.79 0.010 0.02 0.023 0.0122 13.13 13.16 0.03 1.12
63° 64° 60 56.4 1.50 0.0221 2.53 0.010 0.02 0.019 0.0102 13.13 13.16 0.03 1.01
64° 65° 60 56.4 1.50 0.0221 2.27 0.010 0.02 0.015 0.0083 13.13 13.16 0.03 0.91
65° 66° 60 56.4 1.50 0.0221 2.02 0.010 0.01 0.012 0.0067 13.13 13.16 0.03 0.81
66° 67° 60 56.4 1.50 0.0221 1.76 0.010 0.01 0.010 0.0052 13.13 13.16 0.03 0.70
67° 68° 60 56.4 1.50 0.0221 1.50 0.010 0.01 0.007 0.0038 13.13 13.16 0.03 0.60
68° 69° 60 56.4 1.50 0.0221 1.24 0.010 0.00 0.005 0.0027 13.13 13.16 0.02 0.50
69° 70° 60 56.4 1.50 0.0221 0.98 0.010 0.00 0.003 0.0017 13.13 13.16 0.02 0.39
70° 71° 60 56.4 1.50 0.0221 0.72 0.010 0.00 0.002 0.0010 13.13 13.16 0.02 0.29
71° 72° 60 56.4 1.50 0.0221 0.46 0.010 0.00 0.001 0.0004 13.13 13.15 0.02 0.19

107.82 1.30 1.86 2.02 : (OK) Existe presiòn


Tramo Diametro Candidatos Long. Desnivel Caudal fe J J' hf Hn Hm ∆h Veloc.

de a Øe (mm) Øi (mm) (m) (m) ( l/s ) (m) (m) (m) (m) (m) (m) (m/s)

VERIFICACION FINAL DE PRESIONES

DESCRIPCION ECUACIONES VALOR (m) CONDICION

Tolerancia de presiones en SUR ∆H = 2.5 (ha - hns) = ∆Hl + ∆Hd 3.23 VALOR PERMITIDO

Tolerancia de presiones en Laterales ∆Hl = hm - hn = 0.69 2.72 VALOR OBTENIDO

Tolerancia de presiones en Distribuidores ∆Hd = Hm - Hn = 2.02 (OK) CUMPLE

RESUMEN DEL DISTRIBUIDOR


Diam .Candidatos Long. Cant Und Clase

3" 84.1 52.15 10.43 Pzs 5

2.5" 69.4 39.12 7.82 Pzs 5

2" 56.4 16.55 3.31 Pzs 5

Total 91.27 18.25 Pzs 5


DISEÑO DE TUBERIA TERCIARIA:
PARA TRAMO CON PENDIENTE NEGATIVA: -0.0147 t' = 1+ (d/hf)+0.357(-d/hf)^(1.57)

Tramo Diametro Candidatos Long. Desnivel Caudal fe J J' hf i < J'=A d/hf t' t' hf Hn Hm ∆h

de a Øe (mm) Øi (mm) (m) (m) ( l/s ) (m) (m) (m) (m) i >= J'=B (m) (m) (m) (m) hm-hn
0° 1° 88.5 84.1 1.00 0.0147 18.84 0.005 0.11 0.109 0.0390 A 0.3767 0.7004 0.0273 15.13 15.15 0.03
1° 2° 88.5 84.1 1.50 0.0221 18.58 0.005 0.11 0.107 0.0572 A 0.3865 0.6938 0.039711 15.08 15.12 0.04
2° 3° 88.5 84.1 1.50 0.0221 18.32 0.005 0.10 0.105 0.0563 A 0.3933 0.6892 0.038771 15.03 15.07 0.04
3° 4° 88.5 84.1 1.50 0.0221 18.06 0.005 0.10 0.102 0.0548 A 0.4038 0.6822 0.037376 14.98 15.01 0.04
4° 5° 88.5 84.1 1.50 0.0221 17.80 0.005 0.10 0.099 0.0533 A 0.4148 0.6749 0.036001 14.93 14.96 0.04
5° 6° 88.5 84.1 1.50 0.0221 17.54 0.005 0.10 0.097 0.0519 A 0.4262 0.6674 0.034646 14.88 14.91 0.03
6° 7° 88.5 84.1 1.50 0.0221 17.28 0.005 0.09 0.094 0.0505 A 0.4381 0.6596 0.033311 14.83 14.86 0.03
7° 8° 88.5 84.1 1.50 0.0221 17.02 0.005 0.09 0.091 0.0491 A 0.4505 0.6516 0.031997 14.78 14.82 0.03
8° 9° 88.5 84.1 1.50 0.0221 16.77 0.005 0.09 0.089 0.0477 A 0.4635 0.6432 0.030703 14.74 14.77 0.03
9° 10° 88.5 84.1 1.50 0.0221 16.51 0.005 0.09 0.086 0.0464 A 0.4771 0.6346 0.02943 14.69 14.72 0.03
10° 11° 88.5 84.1 1.50 0.0221 16.25 0.005 0.08 0.084 0.0450 A 0.4913 0.6257 0.028177 14.65 14.68 0.03
11° 12° 88.5 84.1 1.50 0.0221 15.99 0.005 0.08 0.081 0.0437 A 0.5061 0.6164 0.026946 14.61 14.63 0.03
12° 13° 88.5 84.1 1.50 0.0221 15.73 0.005 0.08 0.079 0.0424 A 0.5217 0.6068 0.025736 14.56 14.59 0.03
13° 14° 88.5 84.1 1.50 0.0221 15.47 0.005 0.08 0.077 0.0411 A 0.5380 0.5969 0.024547 14.52 14.55 0.02
14° 15° 88.5 84.1 1.50 0.0221 15.21 0.005 0.07 0.074 0.0399 A 0.5551 0.5866 0.02338 14.48 14.51 0.02
15° 16° 88.5 84.1 1.50 0.0221 14.95 0.005 0.07 0.072 0.0386 A 0.5730 0.5759 0.022235 14.44 14.47 0.02
16° 17° 88.5 84.1 1.50 0.0221 14.70 0.005 0.07 0.070 0.0374 A 0.5919 0.5648 0.021112 14.41 14.43 0.02
17° 18° 88.5 84.1 1.50 0.0221 14.44 0.005 0.07 0.067 0.0362 A 0.6117 0.5533 0.020011 14.37 14.39 0.02
18° 19° 88.5 84.1 1.50 0.0221 14.18 0.005 0.06 0.065 0.0350 A 0.6326 0.5414 0.018933 14.33 14.35 0.02
19° 20° 88.5 84.1 1.50 0.0221 13.92 0.005 0.06 0.063 0.0338 A 0.6546 0.5290 0.017878 14.30 14.31 0.02
20° 21° 88.5 84.1 1.50 0.0221 13.66 0.005 0.06 0.061 0.0326 A 0.6778 0.5161 0.016846 14.26 14.28 0.02
21° 22° 88.5 84.1 1.50 0.0221 13.40 0.005 0.06 0.059 0.0315 A 0.7023 0.5027 0.015837 14.23 14.24 0.02
22° 23° 88.5 84.1 1.50 0.0221 13.14 0.005 0.06 0.057 0.0304 A 0.7281 0.4888 0.014853 14.19 14.21 0.01
23° 24° 88.5 84.1 1.50 0.0221 12.88 0.005 0.05 0.055 0.0293 A 0.7555 0.4744 0.013892 14.16 14.18 0.01
24° 25° 88.5 84.1 1.50 0.0221 12.62 0.005 0.05 0.052 0.0282 A 0.7845 0.4594 0.012956 14.13 14.14 0.01
25° 26° 88.5 84.1 1.50 0.0221 12.37 0.005 0.05 0.051 0.0271 A 0.8152 0.4438 0.012046 14.10 14.11 0.01
26° 27° 88.5 84.1 1.50 0.0221 12.11 0.005 0.05 0.049 0.0261 A 0.8478 0.4277 0.011161 14.07 14.08 0.01
27° 28° 88.5 84.1 1.50 0.0221 11.85 0.005 0.05 0.047 0.0251 A 0.8825 0.4109 0.010301 14.04 14.05 0.01
28° 29° 88.5 84.1 1.50 0.0221 11.59 0.005 0.04 0.045 0.0241 A 0.9194 0.3935 0.009469 14.01 14.02 0.01
29° 30° 88.5 84.1 1.50 0.0221 11.33 0.005 0.04 0.043 0.0231 A 0.9587 0.3754 0.008664 13.98 13.99 0.01
30° 31° 88.5 84.1 1.50 0.0221 11.07 0.005 0.04 0.041 0.0221 A 1.0007 0.3567 0.007886 13.96 13.96 0.01
31° 32° 88.5 84.1 1.50 0.0221 10.81 0.005 0.04 0.039 0.0212 A 1.0456 0.3373 0.007137 13.93 13.94 0.01
32° 33° 88.5 84.1 1.50 0.0221 10.55 0.005 0.04 0.038 0.0202 A 1.0936 0.3172 0.006418 13.90 13.91 0.01
33° 34° 88.5 84.1 1.50 0.0221 10.30 0.005 0.04 0.036 0.0193 A 1.1451 0.2965 0.005729 13.88 13.88 0.01
34° 35° 88.5 84.1 1.50 0.0221 10.04 0.005 0.03 0.034 0.0184 A 1.2005 0.2751 0.00507 13.85 13.86 0.01
35° 36° 73 69.4 1.50 0.0221 9.78 0.007 0.08 0.084 0.0450 A 0.4919 0.6253 0.028124 13.81 13.83 0.03
36° 37° 73 69.4 1.50 0.0221 9.52 0.007 0.08 0.080 0.0428 A 0.5170 0.6097 0.026093 13.76 13.79 0.03
37° 38° 73 69.4 1.50 0.0221 9.26 0.007 0.07 0.076 0.0407 A 0.5441 0.5932 0.024121 13.72 13.75 0.02
38° 39° 73 69.4 1.50 0.0221 9.00 0.007 0.07 0.072 0.0386 A 0.5735 0.5756 0.022208 13.69 13.71 0.02
39° 40° 73 69.4 1.50 0.0221 8.74 0.007 0.07 0.068 0.0365 A 0.6054 0.5570 0.020356 13.65 13.67 0.02
40° 41° 73 69.4 1.50 0.0221 8.48 0.007 0.06 0.064 0.0346 A 0.6401 0.5371 0.018567 13.61 13.63 0.02
41° 42° 73 69.4 1.50 0.0221 8.23 0.007 0.06 0.061 0.0326 A 0.6779 0.5160 0.016841 13.58 13.59 0.02
42° 43° 73 69.4 1.50 0.0221 7.97 0.007 0.06 0.057 0.0308 A 0.7193 0.4935 0.015179 13.54 13.56 0.02
43° 44° 73 69.4 1.50 0.0221 7.71 0.007 0.05 0.054 0.0289 A 0.7647 0.4696 0.013584 13.51 13.53 0.01
44° 45° 73 69.4 1.50 0.0221 7.45 0.007 0.05 0.051 0.0272 A 0.8148 0.4441 0.012058 13.48 13.49 0.01
45° 46° 73 69.4 1.50 0.0221 7.19 0.007 0.05 0.047 0.0254 A 0.8700 0.4169 0.010602 13.45 13.46 0.01
46° 47° 73 69.4 1.50 0.0221 6.93 0.007 0.04 0.044 0.0238 A 0.9312 0.3880 0.009219 13.42 13.43 0.01
47° 48° 73 69.4 1.50 0.0221 6.67 0.007 0.04 0.041 0.0221 A 0.9993 0.3573 0.007911 13.40 13.40 0.01
48° 49° 73 69.4 1.50 0.0221 6.41 0.007 0.04 0.038 0.0206 A 1.0753 0.3248 0.006682 13.37 13.38 0.01
49° 50° 73 69.4 1.50 0.0221 6.16 0.007 0.03 0.035 0.0191 B 1.1607 0.2904 0.005536 13.31 13.35 0.04
50° 51° 73 69.4 1.50 0.0221 5.90 0.007 0.03 0.033 0.0176 B 1.2569 0.2543 0.004475 13.29 13.33 0.04
51° 52° 73 69.4 1.50 0.0221 5.64 0.007 0.03 0.030 0.0162 B 1.3660 0.2165 0.003507 13.26 13.30 0.04
52° 53° 73 69.4 1.50 0.0221 5.38 0.007 0.03 0.028 0.0148 B 1.4904 0.1776 0.002636 13.24 13.28 0.04
53° 54° 73 69.4 1.50 0.0221 5.12 0.007 0.02 0.025 0.0135 B 1.6332 0.1380 0.001869 13.22 13.26 0.04
54° 55° 73 69.4 1.50 0.0221 4.86 0.007 0.02 0.023 0.0123 B 1.7981 0.0988 0.001215 13.20 13.24 0.03
55° 56° 73 69.4 1.50 0.0221 4.60 0.007 0.02 0.021 0.0111 B 1.9900 0.0616 0.000685 13.18 13.22 0.03
56° 57° 73 69.4 1.50 0.0221 4.34 0.007 0.02 0.019 0.0100 B 2.2155 0.0292 0.000291 13.16 13.20 0.03
57° 58° 73 69.4 1.50 0.0221 4.09 0.007 0.02 0.017 0.0089 B 2.4828 0.0056 5.01E-05 13.15 13.18 0.03
58° 59° 73 69.4 1.50 0.0221 3.83 0.007 0.01 0.015 0.0079 B 2.8032 -0.0023 -1.83E-05 13.13 13.16 0.03
59° 60° 73 69.4 1.50 0.0221 3.57 0.007 0.01 0.013 0.0069 B 3.1919 0.0162 0.000113 13.13 13.16 0.03
60° 61° 73 69.4 1.50 0.0221 3.31 0.007 0.01 0.011 0.0060 B 3.6702 0.0792 0.000477 13.13 13.16 0.03
61° 62° 60 56.4 1.50 0.0221 3.05 0.010 0.03 0.027 0.0143 B 1.5423 0.1626 0.002332 13.13 13.16 0.04
62° 63° 60 56.4 1.50 0.0221 2.79 0.010 0.02 0.023 0.0122 B 1.8179 0.0945 0.00115 13.13 13.16 0.03
63° 64° 60 56.4 1.50 0.0221 2.53 0.010 0.02 0.019 0.0102 B 2.1773 0.0339 0.000344 13.13 13.16 0.03
64° 65° 60 56.4 1.50 0.0221 2.27 0.010 0.02 0.015 0.0083 B 2.6589 -0.0014 -1.18E-05 13.13 13.16 0.03
65° 66° 60 56.4 1.50 0.0221 2.02 0.010 0.01 0.012 0.0067 B 3.3266 0.0296 0.000197 13.13 13.16 0.03
66° 67° 60 56.4 1.50 0.0221 1.76 0.010 0.01 0.010 0.0052 B 4.2921 0.2232 0.00115 13.13 13.16 0.03
67° 68° 60 56.4 1.50 0.0221 1.50 0.010 0.01 0.007 0.0038 B 5.7677 0.8227 0.003156 13.13 13.16 0.03
68° 69° 60 56.4 1.50 0.0221 1.24 0.010 0.00 0.005 0.0027 B 8.1984 2.512 0.006778 13.13 13.16 0.02
69° 70° 60 56.4 1.50 0.0221 0.98 0.010 0.00 0.003 0.0017 B 12.6569 7.544 0.013187 13.13 13.16 0.02
70° 71° 60 56.4 1.50 0.0221 0.72 0.010 0.00 0.002 0.0010 B 22.337 25.505 0.025262 13.13 13.16 0.02
71° 72° 60 56.4 1.50 0.0221 0.46 0.010 0.00 0.001 0.0004 B 50.861 120.63 0.052472 13.13 13.15 0.02

107.82 1.2979 1.86 2.02

Tramo Diametro Candidatos Long. Desnivel Caudal fe J J' hf i < J'=A d/hf t' t' hf Hn Hm ∆h

de a Øe (mm) Øi (mm) (m) (m) ( l/s ) (m) (m) (m) (m) i >= J'=B (m) (m) (m) (m)

VERIFICACION FINAL DE PRESIONES

DESCRIPCION ECUACIONES VALOR (m) CONDICION

Tolerancia de presiones en SUR ∆H = 2.5 (ha - hns) = ∆Hl + ∆Hd 3.23

Tolerancia de presiones en Laterales ∆Hl = hm - hn = 0.69 : (OK) CUMPLE


2.72
Tolerancia de presiones en Distribuidores ∆Hd = Hm - Hn = 2.02

RESUMEN DEL DISTRIBUIDOR


Diam .Candidatos Long. Cant Und Clase

3" 84.1 52.66 10.53 Pzs 5

2.5" 69.4 39.12 7.82 Pzs 5

2" 56.4 122.86 24.57 Pzs 5


Total 91.77 18.35 Pzs 5

SISTEMA DE RIEGO A PRESION

C) DISEÑO DE TUBERIA SECUNDARIA:

Datos de diseño :
Caudal Terciario : qs (l/s) 18.84 l/s 67806 l/h

Esp. Distribuid :Sd ( m) 122 m.


Long. distribuidor: l ( m) 683.37 m.
Coef. Para tub. PVC : C 150
P. Entrada Terciaria: Hm = 15.15 m.
Cálculos previos:
Pendiente ( i ) = 0.0026673
m (F. Hanzen-Williams) 1.8552
Nº salidas :n 12
Caudal Secundario ( l/s) 37.67 l/s 135613 l/h

F ( n, lo=Se) 0.393
fe (m) de tabla =18.91*d^(-1.87) Condición = Hm-Hn < ∆H = 50.00 m

Tramo Diametro Candidatos Long. Desnivel Caudal fe J J' hf K(V)^2/2g Hn Hm ∆h Veloc.


Observaciones
de a Øe (mm) Øi (mm) (m) (m) ( l/s ) (m) (m) (m) (m) (m) (m) (m) hm-hn (m/s)
7° 6° 168 159.8 65.66 0.18 37.67 0.001 0.02 0.000 1.1359 0.179992 25.08 26.22 1.14 1.88
6° 5° 168 159.8 121.31 0.32 37.67 0.001 0.02 0.000 2.0988 0.179808 23.12 25.08 1.96 1.88
5° 4° 168 159.8 126.31 0.34 37.67 0.001 0.02 0.000 2.1853 0.179808 21.09 23.12 2.03 1.88
4° 3° 168 159.8 121.31 0.32 37.67 0.001 0.02 0.000 2.0988 0.179808 19.14 21.09 1.96 1.88
3° 2° 168 159.8 126.31 0.34 37.67 0.001 0.02 0.000 2.1853 0.179808 17.11 19.14 2.03 1.88
2° 1° 168 159.8 121.31 0.32 37.67 0.001 0.02 0.000 2.0988 0.179808 15.15 17.11 1.96 1.88

682.21 1.82 11.80 1.08 0.00 : (OK) Existe presiòn

NOTA: La pérdida de carga se calcula solo con J, no se considera J'; pues las salidas múltiples no funcionan simultaneamente.Se considera las pérdidas por accesorios.

RESUMEN DEL TUBO SECUNDARIO:


Diam .Candidatos Long. Cant Und Clase

6" 159.8 682.21 136.44 Pzs 5

Total 682.21 136.44 Pzs


SISTEMA DE RIEGO A PRESION

D) DISEÑO DE TUBERIA PRINCIPAL:

Datos de diseño :
Caudal Secundaria : qs (l/s) 37.67 l/s 135613 l/h

Esp. Secundario :Ss ( m) 176 m.


Long. distribuidor: l ( m) 786.24 m.
Coef. Para tub. PVC : C 150
P. Entrada Secundario: Hm = 26.22 m.
Cálculos previos:
Pendiente ( i ) = 0.0027
m (F. Hanzen-Williams) 1.8552
Nº salidas : n 4
Caudal Principal ( l/s) 37.67 l/s 135613 l/h

F ( n, lo=Se) 0.485
fe (m) de tabla =18.91*d^(-1.87) Condición = Hm-Hn < ∆H = 50.00 m

Tramo Diametro Candidatos Long. Desnivel Caudal fe J J' hf K(V)^2/2g Hn Hm ∆h Veloc.


Observaciones
de a Øe (mm) Øi (mm) (m) (m) ( l/s ) (m) (m) (m) (m) (m) (m) (m) hm-hn (m/s)
0° 1° 168 159.8 0.00 0.00 37.67 0.001 0.02 0.000 0.0000 0.3600 38.44 38.80 0.36 1.88
1° 28° 168 159.8 115.32 0.31 37.67 0.001 0.02 0.000 1.9952 0.179808 36.57 38.44 1.87 1.88
28° 21° 168 159.8 223.64 0.60 37.67 0.001 0.02 0.000 3.8692 0.179808 33.12 36.57 3.45 1.88
21° 14° 168 159.8 223.64 0.60 37.67 0.001 0.02 0.000 3.8692 0.179808 29.67 33.12 3.45 1.88
14° 7° 168 159.8 223.64 0.60 37.67 0.001 0.02 0.000 3.8692 0.179808 26.22 29.67 3.45 1.88

786.24 2.10 13.60 1.08 0.00 : (OK) Existe presiòn


NOTA: La pérdida de carga se calcula solo con J, no se considera J'; pues las salidas múltiples no funcionan simultaneamente.Se considera las pérdidas por accesorios.

RESUMEN DEL TUBO PRINCIPAL:


Diam .Candidatos Long. Cant Und Clase

6" 159.8 786.24 157.25 Pzs 7.5

Total 786.24 157.25 Pzs


V = 0.8494*C*R^0.63S^0.54

Elegimos este diametro porque hay menor perdida de carga; además, en fertirrigacion las sales disminuyen el diametro de la tuberia
EQUIVALENCIAS DE Ø
Pulg. (mm)
½ 20
¾ 25
1 32
1 ¼" 40
1½ 50
2 63
2½ 75
3 90
4 110
5 125
6 140
Copyright © -2001 ELRIEGO.COM
Pag: 429 Pizarro

Veloc. Observaciones
(m/s)

3.39

3.34

3.30

3.25

3.20

3.16

3.11

3.06

3.02

2.97

2.92

2.88

2.83

2.79

2.74

2.69

2.65

2.60

2.55

2.51

2.46

2.41

2.37

2.32

2.27

2.23
2.18

2.13

2.09

2.04

1.99

1.95

1.90

1.85

1.81

2.59

2.52

2.45

2.38

2.31

2.24

2.17

2.11

2.04

1.97

1.90

1.83

1.76

1.70

1.63

1.56

1.49

1.42

1.35

1.29

1.22

1.15
1.08

1.01

0.94

0.87

1.22

1.12

1.01

0.91

0.81

0.70

0.60

0.50

0.39

0.29

0.19

: (OK) Existe presiòn