Você está na página 1de 1

Project : EPC Construction of Marine Intake & Outfall System for 700 MW Combined

Cycle Power plant near Pipapav


Location : PIPAPAV, GUJARAT STATE, INDIA
Client : GPPC PIPAPAV POWER COMPANY LTD

Design of Scour Protection for Intake well structure

INPUTS:‐
Coefficient for shape of the structure K = 2 circular/ cylindrical 
Mean current velocity U = 1.85 m/sec
Specific gravity of rock armor Ss = 2.4
2
Acceleration due to gravity g = 9.81 m/sec
Unit weight of armor stone γs = 26 kN/m3
Diameter of the structure D = 3.19 m
Height of the structure L = 10.63 m

2
Diameter of armor stone, D50      =     0.692 ( K.U)
2g ( Ss ‐ 1)
= 0.345 m

Weight of armor stone, W50 (min) =  (D50)3 . γs
= 1.067 kN

Weight of Gradation fractions, W100 (max) = 5 . W50(min)
= 5.333 kN

W100 (min) = 2 . W50(min)
= 2.133 kN

W50 (max) =  1.5 . W50(min)
= 1.6 kN

W30       =  W50(min) / 1.7
= 0.627 kN

W15 (max) =  0.75 . W50(min)
= 0.8 kN

W15 (min) =  0.31 . W50(min)
= 0.331 kN

Thickness (depth) of design, (below water)
1/3
r           =    (W30 / γs )
= 0.3 m

Scour depth,  Sm       =   0.06 . D
= 0.19 m

Length/dia of extent for protection, Ls       =   0.75 . D
= 2.4 m

Provide 110 kg armor stones upto 300 mm depth above seabed for radius 2.4 m from 
outer diameter of intake structure. (as per drwg attached) 