Você está na página 1de 3

Test Report

Report No: SHRL90028/2008


Page: 1 of 3
Date: Sep. 18, 2008

GE INSPECTION TECHNOLOGIES

The below samples were submitted by client and said to be:


Product Description : DM5E
Quantity : 1piece
Sample Receiving Date : Sep. 17, 2008
Testing Period : From Sep. 17, 2008 to Sep. 18, 2008
Test Request : IP54
Test Method : Refer to IEC 60529: 2001 and client’s requirements.
Test Result(s) : For further details, please refer to the following pages.

Signed for and on behalf of


SGS-CSTC Ltd.

Michael Zhang
E&E Reliability Lab
Test Report
Report No: SHRL90028/2008
Page: 2 of 3
Date: Sep. 18, 2008
We have tested the submitted sample(s) as requested and the following results were obtained:

Degree of protection provided by enclosures (IP code)


IP code IP 54
First characteristic numeral Dust-protected Test
Second characteristic numeral Protection against ingress of water test

Test Equipment:

Name Model
Dust Chamber SC-6
Degree of protect against water equipment T041101-01

Test Method: Refer to IEC60529: 2001 and client’s requirements

Test 1. IPX4
Protection against ingress of water
Oscillating angle: 180°/side
Oscillating speed: 4seconds/cycle
Tube radius: 1000mm
Numbers of open holes: 41
Water flow rate 0.07L/min±5%/ hole
Test duration: 10minutes
Test Result(s): Satisfied
No water enters into the sample after the dust-protected test.
Photos:

Before Test After Test


Test Report
Report No: SHRL90028/2008
Page: 3 of 3
Date: Sep. 18, 2008
Test 2. IP5X
Dust-protected Test
Test Dust: 2kg/m3 chamber volume and be kept in suspension during the test
Test Duration: 8hours
Test Result(s): Satisfied
No dust enters into the sample after the dust-protected test.
Photos:

Before Test After Test

*** End of Report ***