TIMESWITCH TERMINAL COMPARISONS

Lifestyle Lifestyle DAY-TO-DAY VARIATIONS Cont... THE LP711 7-DAY ELECTRONIC TIMESWITCH Cont... INTRODUCTION Cont... THE LP112 24hr ELECTRONIC PROGRAMMER Cont...

Common
Neutral

Spare
Earth
Over-riding the program Changing the timings

Live

On

Off
MAKE MODEL If the engineer hasn’t set your timings for you, your programmer Changing the timings
Current Models  Press the SET? button and you’ll see ‘SET PROG?’. will work with a standard program that has been set at the
factory. If this doesn’t suit you, it’s very easy to change it –  Press the SET? button and you’ll see ‘SET PROG?’.
Drayton Tempus 1, 2 (new models) N L 1 3 2 4
SINGLE DUAL Lifestyle LP111, LP711 N L 1 3 2 4 SINGLE DUAL when you’ve read this introductory section, simply go to the
CHANNEL CHANNEL Switchmaster 300 N L 4 1 CHANNEL CHANNEL PROG?
section that contains your programmer model.
Timeswitch Programmer Discontinued/Competitors’ Models Timeswitch Programmer At the side of the display there are four operating modes: PROG?

ACL TC (Towerchron) 2 1 4 7 Set all weekdays


OFF = continuously off.
for heating OR hot water for heating AND hot water Drayton Tempus 1, 2 (old models) N L 1 2 3 4 for heating OR hot water for heating AND hot water  Press the YES button, and you’ll see ON1, the start of your first
TIMED = on for up to 3 periods a day. First you set the times that are going to be the same for each
Switchmaster 980 N L 4 1 heating period. Adjust it in 1-minute steps using the – and +
Danfoss Randall weekday, then you can select each day individually and make
TS15, 75 (Mk18) E N L 1 4 2 5/6 ONCE = on for 1 period a day, from the start of ON1 Remember: buttons. If the – and + buttons are held down, the time
Danfoss Randall TS715 E N L 1 4 2 3 any further adjustments. If you want each day to be quite
to the end of OFF3. changes in 10-minute steps.
Danfoss Randall TS975 E N L 5 4 6 1,2,3 different, go straight to ‘Set each day’.  Make your changes using the SET?, YES/-, and + buttons on
Danfoss Randall SET1, SET1E E N L 5 4 6 ON = continuously on.
the programmer.
Danfoss Randall SET4 E N L 5 4 6  Press the YES button, and the display will ask ‘SET MON to FRI
Danfoss Randall 103, 103E, 103E5, 103E7 4 5 6 3 1 2 Use the SELECT button under the flap to change the mode.  You can’t set ON1 as the last timing before midnight, but you
PROG?’.
Danfoss Randall 911, 971 E N L 5 6 4 2 This won’t alter the timings in your program, which you can can set OFF3 after midnight – providing it’s not more than 23
Grasslin Towerchron QE1 N L 2 4 3 return to by selecting TIMED. hours and 59 minutes after ON1.
Grasslin Towerchron T2001, T2001Q E N L 7
 Press SET?, and you’ll see OFF1, the end of your first heating
Honeywell ST 6100A, ST 6100C N L 1 4 2 MON TUE WED THU FRI  You need to set the timings in sequence – i.e. ON1, OFF1, ON2,
Honeywell ST 7000B L 3 2 THE LP111 24hr ELECTRONIC TIMESWITCH PROG? period. Adjust this in the same way, press SET?, then repeat the
OFF2, ON3, OFF3. If you get out of sequence, the display will
Horstmann Centaur SC1, SC7 N L 4 3 procedure for ON2, OFF2, ON3 and OFF3.
LP111, LP711 LP112, LP241, LP522, LP722 LP111, LP711 LP112, LP241, LP522, LP722 flash a warning.
Horstmann Centaur Plus, C11, C17 N L 2 4 3
LP111 – a 24hr program, up to 3 heating periods each day,  Press YES and you’ll see ON1, the start of your first heating
Horstmann Emerald 423, Pearl Auto E N L 3 4 period. Adjust it in 1-minute steps using the – and + buttons.
and every day the same.
Horstmann 517, Coronet, H11, H17 E N L 5 4 6
If the – and + buttons are held down, the time changes in SWITCHING
Landis & Staefa RWB3 N L 4 3 Want to leave a timing as it is? Just press SET? and move on
SINGLE DUAL Landis & Staefa
Landis & Staefa
RWB30, RWB50, 100, 152, 170
RWB7 N
N
L
L
2
2
4
4
3
3
1
SINGLE DUAL to the next one.
If you need to reset your timings to the standard program
10-minute steps.
ON 1 – start of first timed period

CHANNEL CHANNEL Potterton Myson


Sangamo
EP4000, 4001, 4002, 5002
M6 E
N
4
L
6
5
3
4
1
2
2
CHANNEL CHANNEL and start again, press ‘SET’ and ‘+’ together to go back to
the pre-set program.
OFF 1 – end of first timed period
 When you press SET? after setting OFF3, the programmer will
return to normal operation.
Smiths Centroller Mk1, Mk2 N L 3 2 ON 2 – start of second timed period
Smiths Centroller 30 1 2 4/5
THE LP241 24hr ELECTRONIC PROGRAMMER
Smiths Centroller 300, 980 N L 4 1  Press SET?, and you’ll see OFF1, the end of your first heating OFF 2 – end of second timed period
The standard program
Installation Instructions Sunvic Select 107 N L 1 3 2 4 User Instructions period. Adjust this in the same way, press SET?, then repeat ON 3 – start of third timed period LP241 – a 24hr program, with central heating and hot water
Sunvic SP20, SP35 N L 3 5 4 S Your system will come on for up to 3 heating periods every
06490033001 ISSC
Venner Vennerette N L LINE LOAD
06490033001 ISSC the procedure for ON2, OFF2, ON3 and OFF3. working independently for up to 3 heating periods each day,
24hrs. ON1 starts the first one, OFF1 finishes it, and so on. OFF 3 – final switch-off of the day and every day the same.
Climate Controls Europe Climate Controls Europe Notice that ON2 and OFF2 are set to the same time.* This
If the timings haven’t been set for you, then your programmer
Sales: 0845 1305522 / Technical Helpline: 0845 1307722 Sales: 0845 1305522 / Technical Helpline: 0845 1307722 means your system won’t respond, but if you want to activate
Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk Email: customer.care@invensys.com / Web: www.draytoncontrols.co.uk will still be on the factory-set standard 24hr program, with
that middle period or change any other timings – read on. The engineer has set your program and timings – you central heating and hot water operating together on the
won’t need to do anything else. Just keep this guide in a same timings for every day of the week. But it’s easy to make
PROGRAMMER TERMINAL COMPARISONS Set each day changes, and have heating and water working independently
safe place for future reference.
INSTALLATION INSTRUCTIONS SWITCHING STANDARD PROGRAM – just follow the instructions.
User’s Instructions
H/W on
H/W off
Neutral

C/H on
 If, after you’ve set OFF3 you want to fine-tune one or more

C/H off
Want to leave a timing as it is? Press SET? and move on to
Earth

Live ON 1 – start of first timed period 6.30am DAY-TO-DAY VARIATIONS


PLEASE NOTE: INSTALLATION MUST ONLY BE MAKE MODEL weekdays, press SET? until you find the first day you want to the next one.
CARRIED OUT BY A QUALIFIED ELECTRICIAN OR Current Models TIMESWITCHES OFF 1 – end of first timed period 8.30am adjust – then go through the procedure, altering any time you
Sometimes you might need to change the way you use your
If you need to reset your timings to the standard program
HEATING ENGINEER. Drayton Tempus 6, 7 (new models) N L 1 2 3 4 wish. Press SET? to move on to the next day. When you’ve and start again, press ‘SET’ and ‘+’ together to go back to
ON 2 – start of second timed period* 12.00pm central heating or hot water temporarily – perhaps due to an the pre-set program.
MAKE SURE MAINS INPUT HAS A 3 AMP FUSE. Lifestyle LP112, LP241, LP522, LP722 N L 1 2 3 4 finished, press SET? until you see ‘SET SAT SUN PROG?’.
Switchmaster 400, 600 N L 4 3 1 OFF 2 – end of second timed period* 12.00pm unusually cold day, or exceptional demand for hot water. If you don’t press anything for two minutes, the programmer
(no connection to terminal 4 on 600)
INTRODUCTION Here’s how to do it – without affecting your program. automatically goes back to normal operation.
TECHNICAL DATA
Switchmaster 805 N L 4 2 3 1
ON 3 – start of third timed period 4.30pm
Lifestyle Timeswitches will automatically control your system MON
Switching on and off The standard program
Discontinued/Competitors’ Models OFF 3 – final switch-off of the day 10.30pm PROG?

LP112, LP241, LP522 & LP722 PROGRAMMERS by switching it on and off at times that suit you. The red light Your system will come on for up to 3 heating periods every 24hrs.
ACL MP (Towerchron) 2 1 6 10 on the front of the timeswitch shows when it’s on. On the front of the programmer there are two Advance buttons ON1 starts the first one, OFF1 finishes it, and so on. Notice that on
LP111 & LP711 TIMESWITCHES
ACL FP (Towerchron) 2 1 8 11 6 10 Changing the timings  If you don’t want to alter any individual days, keep pressing – one for central heating and one for hot water. They allow you the standard program ON2 and OFF2 are set to the same time for
Drayton Tempus 3, 4, 6, 7 (old models) N L 1 2 3 4 SET? until you see ‘SET SAT SUN PROG?’. to switch either on or off, irrespective of the program. So if the
 LP111 – a 24hr program, up to 3 heating periods  Press the SET? button and you’ll see ‘SET PROG?’. both central heating and hot water. * This means your system won’t
Voltage 230V AC +10% - 10% 50Hz Switchmaster 905, 9001 N L 4 2 3 1 heating is off, and you want warmth now – press Advance to respond, but if you want to activate that middle period, or change
Danfoss Randall CP15, CP715, FP15, FP715 (Mk18) E N L 1 2 3 4 each day, and every day the same. Set weekend
switch it on, and it will stay on until the end of the next OFF any other timings – read on.
Programmer Rating 2 (1) A 230V AC each switch Danfoss Randall 3020P, 3060 E 7 6 4 2
 LP711 – a 7-day program, allowing for different period. Or if the hot water is on and you don’t need it, press
Danfoss Randall 4033 (link 1-6) E 7 6 5 3 4 2
Timeswitch Rating 2 (1) A 230V AC timings on each day of the week, up to 3 heating periods Advance and it will go off until the beginning of the next ON
Danfoss Randall 102, 102E, 102E5, 102E7 (link 6-3) E 5 6 1 2 PROG?
STANDARD PROGRAM
Danfoss Randall 701 (link L-5 and 5-6) E N L 3 1 each day. SAT SUN
period. SWITCHING
Ambient temp Operating: 0º to 45ºC
Storage: -20ºC to 50ºC
Danfoss Randall 702 (link L-5 and 5-6) E N L 4 2 3 1  Press the YES button, and you’ll see ON1, the start of your first CH HW
If the engineer hasn’t set your timings for you, your timeswitch
Danfoss Randall 922, 972 (link L-2 and 2-5) E N L 1 4 3 6 heating period. Adjust it in 1-minute steps using the – and + Over-riding the program
Danfoss Randall SET2, SET2E, SET3E, SET3M, FP975 E N L 3 6 1 4 will work with a standard program that has been set at the  Press YES and alter ON1, OFF1, ON2, OFF2, ON3 and OFF3 ON 1 – start of first timed period 6.30am 6.30am
Without mains power Display: blank buttons. If the – and + buttons are held down, the time
SET5 (link L-2 and 2-5) factory. If this doesn’t suit you, it’s very easy to change it – times in the same way.
Time: always kept changes in 10-minute steps. OFF 1 – end of first timed period 8.30am 8.30am
Grasslin Towerchron DP 72, QE2 N L 1 2 3 4 when you’ve read this introductory section, simply turn to
Program times: always preserved ON 2 – start of second timed period* 12.00pm 12.00pm
Honeywell ST 699/799 (link L-5 and 5-8) N L 7 4 6 3 the page for your timeswitch model. Set each day
Programming resolution 1 minute Honeywell ST 6200, ST 6300, ST 6400, ST 6450 N L 1 2 3 4
 If, after you’ve set OFF3 for both SAT & SUN, you want to fine- OFF 2 – end of second timed period* 12.00pm 12.00pm
Honeywell ST 7100 (link L-3 and 3-6) N L 7 4 8 5
Wiring Fixed wiring only, to comply with Horstmann 525, 527, 425 Diadem, H21, H27, E N L 3 6 1 4 tune Saturday or Sunday, press SET? until you find the first day On each side of the display there are four operating modes – ON 3 – start of third timed period 4.30pm 4.30pm
current IEE regulations H121, Tiara (link L-2 and 2-5) you want to adjust – then go through the procedure, altering one group for central heating, the other for hot water. You can
OFF 3 – final switch-off of the day 10.30pm 10.30pm
Horstmann Centaur Plus, C21, C27 N L 1 2 3 4  Press SET?, and you’ll see OFF1, the end of your first heating any time you wish. Press SET? to move on to the next day. change modes with immediate effect by using the appropriate
Maintenance Must be maintained by a qualified Landis & Staefa* RWB2, RWB2E, 20, 40, 102, 200, N L 1 2 3 4 period. Adjust this in the same way, press SET?, then repeat the When you press SET? after setting your hot water for Sundays, SELECT button. This won’t alter the timings in your program,
electrician or heating engineer 252 & 270, RWB9 Remember:
procedure for ON2, OFF2, ON3 and OFF3. the programmer will go back to normal operation. which you can return to by selecting TIMED. Changing the timings
Myson Microtimer (link L-5 and 5-8) N L 7 4 6 3
 Make your changes using the SET?, YES/-, and + buttons.
Lifestyle Programmers and Timeswitches conform to the
Potterton Myson All EP2000’s, EP3000’s, EP6000’s N L 1 2 3 4  Press the SET? button and you’ll see ‘SET PROG?’.
OFF = continuously off.
(link L-5 and N-N)  You can’t set ON1 as the last timing before midnight, but you
essential requirements of these Directives: Potterton Myson* Mini Minder N L 1 2 3 4
can set OFF3 after midnight – providing it’s not more than 23 SAT TIMED = on for up to 3 periods a day.
Sunvic Select 207 N L 1 2 3 4
89/336/EEC – Electromagnetic compatibility hours and 59 minutes after ON1. ONCE = on for 1 period a day, from the start of ON1
Sunvic SP50, SP100 (link L-3) N L 1 4 2 5
73/23/EEC – Low voltage to the end of OFF3.
 You need to set the timings in sequence – i.e. ON1, OFF1, ON2,  When you press SET? after setting OFF3, the timeswitch will  If you don’t want to alter either day, keep pressing SET? PROG?

* Can simply be removed from the backplate and replaced without any disturbance to the existing wiring. OFF2, ON3, OFF3. If you get out of sequence, the display will return to normal operation. until the programmer goes back to normal operation. ON = continuously on.
flash a warning. Set the central heating
THE LP711 7-DAY ELECTRONIC TIMESWITCH THE LP112 24hr ELECTRONIC PROGRAMMER
 Press the YES button, and the display will ask ‘SET CH PROG?’.
BEFORE INSTALLATION

First, make sure the mains supply is switched off!


WIRING THE TIMESWITCH
LP711 – a 7-day program, allowing for different
User’s Instructions LP112 – a 24hr program, with linked central heating and hot
PROGRAMMERS
CH
SWITCHING timings on each day of the week, up to 3 heating periods water on for up to 3 heating periods each day, and every day
Make the wiring connections as
PROGRAMMER ONLY above. Note that the output ON 1 – start of first timed period each day. the same. PROG?

contacts are voltage-free, so If the timings haven’t been set for you, then your programmer
The programmer must be set to the type of system it is to con- OFF 1 – end of first timed period Want to leave a timing as it is? Just press SET? and move on
trol. The link on the back of the unit has two settings – P and G. power needs to be put on to If the engineer has set your program and timings – you will still be on the factory-set standard 24hr program, with  Press YES and you’ll see ON1, the start of your first central
to the next one. central heating and hot water operating together on the
Terminal 1 either by linking from ON 2 – start of second timed period won’t need to do anything else. Just keep this guide in a heating period. Adjust it in 1-minute steps using the – and +
P = a fully pumped and controlled system – allowing If you need to reset your timings to the standard program and same settings for every day of the week. But it’s easy to
Terminal L or from a separate safe place for future reference. buttons. If the – and + buttons are held down, the time
heating and hot water to be set separately. OFF 2 – end of second timed period start again, press ‘SET’ and ‘+’ together to go back to the make changes – just follow the instructions.
supply with a 3A fuse. changes in 10-minute steps.
G = a gravity-fed hot water system – which does not allow pre-set program. Want to leave a timing as it is? Press SET? and move on to
ON 3 – start of third timed period INTRODUCTION
independent setting of heating without hot water, though the next one.
hot water can be controlled alone. OFF 3 – final switch-off of the day If you need to reset your timings to the standard program
The standard program Lifestyle Programmers will automatically switch your central and start again, press ‘SET’ and ‘+’ together to go back to
WIRING THE PROGRAMMER
Your system will come on for up to 3 heating periods every heating and hot water on and off at times that suit you. the pre-set program.
USING AN EXISTING WALL-PLATE
USING A DRAYTON SIMP-L-FIT, ALTHOUGH NOT If the engineer has set your program and timings – you won’t 24hrs. ON1 starts the first one, OFF1 finishes it, and so on. Depending on your system, central heating and hot water If you don’t press anything for two minutes, the programmer  Press SET?, and you’ll see OFF1, the end of your first central
Loosen the securing screws on the old programmer and NECESSARY, WILL MAKE THIS INSTALLATION EASIER. Notice that ON2 and OFF2 are set to the same time.* This can either both come on and off at the same time, or work automatically goes back to normal operation. heating period. Adjust this in the same way, press SET?, then
need to do anything else. Just keep this guide in a safe place
unplug it. Check that there’s 70mm clearance to the right of for future reference. means your system won’t respond, but if you want to activate independently. The red light on the front of the programmer repeat the procedure for ON2, OFF2, ON3 and OFF3.
the wall-plate, and 25mm above it. Check the chart on the Connection Charts that middle period or change any other timings – read on. shows when each one is on. The standard program
next page to compare terminals and if necessary, change the Your system will come on for up to 3 heating periods every
Arrowed numbers relate to
wiring of the wall-plate to suit. Now plug the Lifestyle unit into DAY-TO-DAY VARIATIONS There are 4 models in the Lifestyle range: 24hrs. ON1 starts the first one, OFF1 finishes it, and so on.
the junction box.
the wall-plate and tighten the securing screws. Notice that on the standard program ON2 and OFF2 are set
 LP112 – a 24hr program, with linked central heating and hot to the same time.* This means your system won’t respond,
Consult boiler handbook STANDARD PROGRAM
Check the 3A fuse, and switch on the mains. Sometimes you might need to change the way you use your SWITCHING water on for up to 3 heating periods each day, and every day Set the hot water
for details of pump but if you want to activate that middle period, or change any
overrun wiring. system temporarily – perhaps due to an exceptionally cold day. MON-FRI SAT-SUN the same. other timings – read on.
FITTING A NEW WALL-PLATE  When you press SET? after setting OFF3 for the central heating,
Here’s how to do it – without affecting the timings in your ON 1 – start of first timed period 6.30am 7.00am  LP241 – a 24hr program, with central heating and the display will ask ‘SET HW PROG?’.
*Thermostat Key Wiring Colour Codes program. hot water working independently for up to 3 heating periods
The ideal location is 1.4m above floor level, with reasonable C Common GR Grey OFF 1 – end of first timed period 8.30am 9.00am SWITCHING STANDARD PROGRAM
lighting, good access, no condensation, no extremes of Y Yellow each day, and every day the same.
H Call for Heat ON 1 – start of first timed period 6.30am
S Satisfied BK Black ON 2 – start of second timed period* 12.00pm 12.00pm
temperature, and a supporting surface that fully covers the Switching on and off  LP522 – a 5/2-day program allowing for different
N Neutral BL Blue
back of the unit. BR Brown OFF 2 – end of second timed period* 12.00pm 12.00pm timings at the weekends, with central heating and hot water OFF 1 – end of first timed period 8.30am
E Earth On the front of the timeswitch is an Advance button. It allows
Position with 70mm clearance to the right, 25mm above, and L Live RD Red working independently for up to 3 heating periods each day.
W White you to switch your system on or off, irrespective of the program. ON 3 – start of third timed period 4.30pm 4.00pm ON 2 – start of second timed period* 12.00pm  Press YES, then set your times in the same way. Remember, in
sufficient room to access the securing screws underneath. OR Orange Press Advance to switch it on, and it will stay on until the end  LP722 – a 7-day program allowing for different this mode you can have different times to your central heating if
YG Yellow/Green OFF 3 – final switch-off of the day 10.30pm 11.00pm OFF 2 – end of second timed period* 12.00pm
Fix, with terminals at the top, either direct to a flat wall using wall of the next OFF period. Turn it off, and it will stay off until the timings on each day of the week, with central heating and you wish.
plugs and No. 6 x 1” (25mm) woodscrews, or on a flush mount- beginning of the next ON period. hot water working independently for up to 3 heating periods ON 3 – start of third timed period 4.30pm
ing single conduit box type UA1 (BS4662) using M3.5 x 14 bolts. each day.  When you press SET? after setting OFF3 for the hot water, the
DO NOT USE A SURFACE MOUNTING BOX. OFF 3 – final switch-off of the day 10.30pm programmer will return to normal operation.
THE LP522 5/2-DAY ELECTRONIC PROGRAMMER THE LP722 7-DAY ELECTRONIC PROGRAMMER THE LP722 7-DAY ELECTRONIC PROGRAMMER Cont... SETTING THE DATE Cont... WIRING THE PROGRAMMER Cont...

LP522 – a 5/2-day program allowing for different timings at LP722 – a 7-day program allowing for different timings on each Set weekend Set the month Connection Charts
the weekends, with central heating and hot water working day of the week, with central heating and hot water working  Press SET? and the month will start to flash. Use the – and +
independently for up to 3 heating periods each day. independently for up to 3 heating periods each day.  Press YES, and alter the central heating and hot water times in buttons to adjust.
the same way.
If the timings haven’t been set for you, then your programmer If the timings haven’t been set for you, then your programmer
will still be on the factory-set standard program. This means will still be on the factory-set standard program. This has central  When you press SET? after OFF3 for HW SAT SUN, the pro-
that central heating and hot water will operate together, with heating and hot water operating together – with the option of grammer will ask the question TEST? If you want to test your
ROOM THERMOSTAT Gravity HW, Pumped CH with Room Stats
the same timings for weekdays and different ones for the having different timings for each day of the week. But it’s easy E L N C H
weekend. But it’s easy to make changes, and have heating to make changes, and have heating and water working
program, see below, otherwise press SET? again. If you don’t
RTS 1&2 N L 3 PROGRAMMER PUMP
and water working independently – just follow the instructions. want to test your program, press SET? again – and you’ll be Set the day RTS 4,5&6 #
independently – just follow the instructions. L N 1 3 3 E
asked the question SET H’DAY? If you want to set a holiday  Press SET? and the day will start to flash. Use the – and + but-
Want to leave a timing as it is? Press SET? and move on to Want to leave a timing as it is? Press SET? and move on to the
ETS 1 E 4 1 2
N L 1 2 3 4
SET TO 2 N
switch off, see page 23, otherwise press SET? again.If you’re tons to adjust. 5 L
the next one.
next one. not going to program in a holiday switch-off, then press SET? 'G'
If you need to reset your timings to the standard program 3 1 2 4 5
If you need to reset your timings to the standard program and again and your programmer will go back to normal operation.
and start again, press ‘SET’ and ‘+’ together to go back to #- LINK L-1 FOR 230V OUTPUT
start again, press ‘SET’ and ‘+’ together to go back to the
the pre-set program. L 1 2 1 7 4
pre-set program. Test your program
N 2
If you don’t press anything for two minutes, the programmer
automatically goes back to normal operation.
If you don’t press anything for two minutes, the programmer  This test facility allows you to run through your program to E 3
JUNCTION BOX BOILER
automatically goes back to normal operation. Set the Day Light Saving
check that the timings are exactly what you want. 3 E
 Press SET? and the current DLS status will start to flash for day Switched and Fused 1 2 3 4 5 6 7 8 9 10 11 12
2 N
The standard program  Answer YES to TEST? and the display will show Monday and light saving (British Summer Time). Use the – and + buttons to (3A) Mains input L N E 7 L
The standard program turn on or off.
a time just past midnight. Press YES again and hold it down –
Your system will come on for up to 3 heating periods every
Your system will come on for up to 3 heating periods every † For pump overrun boilers consult
24hrs. ON1 starts the first period, OFF1 finishes it, and so on. and the display will start to run through the days of the week, manufacturer's instructions LWC3
24hrs. ON1 starts the first period, OFF1 finishes it, and so on.
Notice that ON2 and OFF2 are set to the same time.* This pausing for a few seconds when it reaches an ON or an OFF *
Notice that ON2 and OFF2 are set to the same time.* This See Thermostat Key
means your system won’t respond, but if you want to activate time. At each pause, the appropriate lights and circuits will
means your system won’t respond, but if you want to activate
that middle period, or change any other timings – read on. that middle period, change any other timings – read on. come on.

 Release the YES button, and the display will stop running  Press SET? to go back to normal operation.
WEEKDAYS WEEKENDS
SWITCHING and give you longer to identify a timing.
WEEKDAYS WEEKENDS
HW CH HW CH SWITCHING
ON 1 – start of first timed period 6.30am 6.30am 7.00am 7.00am HW CH HW CH  Press YES once more, and the display will start running again –
OFF 1 – end of first timed period 8.30am 8.30am 9.00am 9.00am
ON 1 – start of first timed period 6.30am 6.30am 7.00am 7.00am and will continue all through the week until you press SET? USERS NOTES
ON 2 – start of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm OFF 1 – end of first timed period 8.30am 8.30am 9.00am 9.00am  Press SET? and your programmer will go back to normal
Mid-Position Valve System
OFF 2 – end of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm
ON 2 – start of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm operation.
OFF 2 – end of second timed period* 12.00pm 12.00pm 12.00pm 12.00pm ROOM THERMOSTAT PROGRAMMER CYLINDER THERMOSTAT
ON 3 – start of third timed period 4.30pm 4.30pm 4.00pm 4.00pm Remember - The display shows the strict time sequence, so
ON 3 – start of third timed period 4.30pm 4.30pm 4.00pm 4.00pm E L N C H * S C H
OFF 3 – final switch-off of the day 10.30pm 10.30pm 11.00pm 11.00pm ON1 for HW could be followed by ON1 for CH, then OFF1 for RTS 1&2 N L 3
N L 1 2 3 4
SET TO HTS 3
OFF 3 – final switch-off of the day 10.30pm 10.30pm 11.00pm 11.00pm HW etc. RTS 4,5&6 L N 1 3 # 2 C 1
ETS 1 E 4 1 2
'P'
Changing the timings
Changing the timings Set a holiday switch-off
 Press the SET? button and you’ll see ‘SET PROG?’. 3 1 2 4 5 2 1 8 6 4 8 6 7
 Press the SET? button and you’ll see ‘SET PROG?’. Using this feature you can program your system to switch off #- LINK L-1 FOR 230V OUTPUT
while you’re on holiday, then switch back on again in time to
JUNCTION BOX
have the house warm for your return. 1 2 3 4 5 6 7 8 9 10 11 12 PUMP
L N E 3 E
 Press SET? three times and you’ll see ‘SET H’DAY?’
PROG?
PROG? 2 N
7 L
Set the weekday central heating  Press YES to SET H’DAY? and the display will show ‘00’. LWC3
Set all weekdays L 1 5 8 7 2 3
 Press the YES button, and the display will ask ‘SET CH MON to  Using + and -, set the number of days you want the system to N 2
FRI PROG?’. First you set the times that are going to be the same for each E 3
be off.
weekday, then you can select each day individually and make
any further adjustments. If you want each day to be quite differ-  Press SET, the display will show ‘H’DAY’ and the programmer Switched and Fused W GR OR BL YG BOILER
CH
(3A) Mains input †
ent, go straight to ‘Set each day.’ will switch off the system. It will then return to normal operation MID-POSITION VALVE 3 E
MON TUE WED THU FRI 2 N
PROG? after the set number of days. LIFESTYLE 679H340-30L0 (22mm) 7 L
 Press the YES button, and the display will ask ‘SET MON to FRI
LIFESTYLE 779H340-30L0 (28mm)
PROG?’. DRAYTON FLOWSHARE 2
 Press YES and you’ll see ON1, the start of your first central Remember - The programmer counts each pass through
Honeywell
heating period. Adjust it in 1-minute steps using the – and + midnight as a day. So if on a Saturday morning you don’t want † For pump overrun boilers consult V4073A
buttons. If the – and + buttons are held down, the time the heating on again until Tuesday morning, set for 3 days. manufacturer's instructions Landis & Gyr
changes in 10-minute steps. MON TUE WED THU FRI
* See Thermostat Key MAV 3
PROG?

SETTING THE CLOCK AND DATE

 Press YES and the display will ask ‘SET CH MON to FRI Applicable to all models.
PROG?’.
SETTING THE CLOCK
 Press SET?, and you’ll see OFF1, the end of your first central CH

heating period. Adjust this in the same way, press SET?, then MON TUE WED THU FRI
The clock in your programmer has been set at the factory,
repeat the procedure for ON2, OFF2, ON3 and OFF3.
PROG?
and automatically accounts for British Summer Time.
However, should you need to set the clock, read on. Spring-Return 2-Valve System
 Press YES, and you’ll see ON1, the start of your first central
ROOM THERMOSTAT PROGRAMMER CYLINDER THERMOSTAT
heating period. Adjust it in 1-minute steps using the – and +
 Press the SET? button until you see SET CLOCK?. E L N C H * S C H
buttons. If the – and + buttons are held down, the time RTS 1&2 N L 3 SET TO
N L 1 2 3 4 HTS 3
changes in 10-minute steps. RTS 4,5&6 L N 1 3 # 2 C 1
Set weekday hot water ETS 1 E 4 1 2 'P'
 When you press SET? after setting OFF3 for the central heating,
the display will ask ‘SET HW MON to FRI PROG?’. 3 1 2 4 5 2 1 6 4 8 6
#- LINK L-1 FOR 230V OUTPUT
Set the hour JUNCTION BOX
 Press SET?, and you’ll see OFF1, the end of your first central
1 2 3 4 5 6 7 8 9 10 11 12 PUMP
 Press YES once, and then the hour will start to flash. Use the L N E 3 E
heating period. Adjust this in the same way, press SET?, then 2 N
– and + buttons to set the hour, checking for AM and PM.
repeat the procedure for ON2, OFF2, ON3 and OFF3. 7 L
 Press YES, then set your times in the same way. Remember, in LWC3
this mode you can have different times to your central heating if L 1 1 7 5 2 3 1 7 8 2 3
N 2
you wish. E 3
GR OR BR BL YG GR OR BR BL YG BOILER
Set weekend central heating Switched and Fused
Set the minute (3A) Mains input †
 When you press SET? after setting OFF3 for the weekday cen- CH VALVE DHW VALVE 3 E
 When you press SET? after OFF3 for the weekday hot water, 2 N
the display will ask ‘SET CH SAT SUN PROG?’. Press YES to
tral heating, the display will ask ‘SET HW MON to FRI PROG?’.  Press SET?, and the minutes will start to flash. Use the – and + LIFESTYLE 679H308-30L1 7 L
buttons to set the exact time. LIFESTYLE 779H33530L10
confirm, and alter the times in the same way. DRAYTON ZV22
Honeywell
CH † For pump overrun boilers consult V4043H1056
manufacturer's instructions Landis & Gyr
ZAV222
SAT SUN

 Press YES, then set your hot water times in the same way.
* See Thermostat Key
Remember, in this mode you can have different times to your
Set weekend hot water  Press SET?, and ‘SET DATE?’ appears in the display.
central heating if you wish.
If you don’t want to change the date press SET? to go back to Make the wiring connections, as above, for the appropriate system.
 When you press SET? after OFF3 for the weekend central
heating, the display will ask ‘SET HW SAT SUN PROG?’. Set each day
normal operation. If you do, go on to the next section.
INSTALLERS/ENGINEERS NOTES
For surface wiring, snap out the cable entry strip on the bottom edge
Press YES, and follow the procedure. If, after you’ve set OFF3 for your hot water, you want to fine-tune of the wall-plate. Lifestyle units are double-insulated and need no earth
one or more weekdays, press SET? until you find the first day SETTING THE DATE connection, but an earthing continuity (loop) terminal is provided for
 When you press SET? after OFF3 for HW SAT SUN, the
you want to adjust – then go through the procedure, altering any convenience.
programmer will go back to normal operation. The weekday is automatically calculated from the date, so if
time you wish. Press SET? to move on to the next day. When the weekday is incorrect you’ll need to reset the date. After wiring, plug in the unit and tighten the securing screws.
you’ve finished, press SET? until you see ‘SET SAT SUN Check the mains input has a 3A fuse, and switch on the mains.
PROG?’. Then set the timings as shown in the User’s Guide.
 Press the SET? button until you see SET DATE?.

ALWAYS SWITCH OFF THE MAINS BEFORE REMOVING


THE LIFESTYLE TIMESWITCH/PROGRAMMER – AND
MON
PROG? NEVER FIT IT TO A LIVE WALL-PLATE!

If you don’t want to alter any individual days, keep pressing Set the year
SET? until you see ‘SET SAT SUN PROG?’.
 Press YES and the year will start to flash. Use the – and + but-
tons to adjust.