Você está na página 1de 1

PAGE A HARCO MFG.

CO Tel: 503-244-7571
Calcul Presure Drop 7700 S.W. 69 TH. Fax: 503-244-75891
REV. 02/02 Portland, OR 97223 USA (E-mail) harco@teleport.com
(web site) www.hapco.org

CALCULATION OF BACK PRESSURE OF SILENCER

Item # Silencer Name of Item # Silencer Name of


Model Model Model Model
1 SFH Super Critical Grade 10 RFH Residential Grade
2 LPRS Super Critical Grade 11 RSL Residential Grade
3 SCSC Super Critical Grade 12 IRTS Residential Grade
4 VCS Super Critical Grade 13 SASR Residential Grade S.A.
5 VRS Critical Grade 14 RSL Residential Grade S.A.
6 CFHI Critical Grade 15 VRSA Critical Grade S. A.
7 CSCS Critical grade 16 VCSA Super Critical Grade S. A.
8 CFH Critical grade 17 M Industrial Grade
9 HCY Critical Grade 18 EXT Extreme grade

Choose Silencer model LPRS MODEL


Introduce Exhaust CFM 63558
Introduce Diameter of Outlet (in) 16 Introduce Lbs/Hr
Introduce Temp. (F) 104 or Kg/s
Introduce Max. BP of Engine 20 Introduce Temp. (C)
Inlet/Outlet Configuration Introduce BP of Piping
(FOR TUBULAR SILENCERS ONLY) & Elbows

0 Exhaust Temp. 460 Lbs C 32 Lbs 0 Kg


63558 
ACFM x TempF  9 x  32 1  7936.56 x10
2275 Hr 5 104 Hr Second
Calculate Outlet Flow Area

x  0.08333 xdiameter
0 6 2
Flow Area ( ft6) 2  0  0.7854 xd 2 x 0.0069444  0.005454 xd 2
4
Outlet Flow Area 1.396
Temp (F) 104
CFM 63558

Calculate Velocity ft/min (V) Exhaust CFM0


V   45521
Silencer Flow Area
ATENTION: Velocity too High, you should increase the size of diameter

Calculate Back Pressure (in H2O) END


2 IN-END OUT
V 530
P  cx SIDE2 IN-END
x OUT  728.4
4005 (T  460
SIDE IN-SIDE OUT )
ATTENTION: This Silencer will not work BP is to High
Note: Exhaust Velocity should not exceed 9000 ft/min on all Critical and Super Critical applications and
velocity should not exceed 12000 ft/min for the rest of the applications