Triple-multiband Panel Dual Polarization Half-power Beam Width Adjust. Electr.

Downtilt

790 960 X 65 2 14

1710 2180 1710 2180 X 65 0 14 X 65 0 14

set by hand or by optional RCU (Remote Control Unit)


XXXPol Panel 790960/17102180/17102180 65/ 65/65 16.5/16.5/16.5dBi 214/014/014T
Type No. Frequency range Polarization Average Gain: (dBi) 17102180 MHz (Syst. bottom) 17102180 MHz (Syst. top) Tilt Horizontal Pattern: Half-power beam width Front-to-back ratio (18030) Cross polar ratio Maindirection 0 Sector 60 Tracking Vertical Pattern: Half-power beam width Electrical tilt Sidelobe suppression for first sidelobe above main beam Impedance VSWR Isolation: Intrasystem Isolation: Intersystem Intermodulation IM3 Max. power per input

80010291V01
790960 17102180 17102180 790 866 MHz 824894 MHz 880960 MHz 17101880 MHz 18501990 MHz 19202180 MHz +45, 45 +45, 45 +45, 45 +45, 45 +45, 45 +45, 45 16.2 ... 16 ... 15.7 16.3 ... 16.1 ... 15.8 16.4 ... 16.2 ... 15.8 15.9 ... 15.9 ... 15.5 16.2 ... 16.2 ... 15.7 16.3 ... 16.3 ... 15.8 15.8 ... 15.8 ... 15.4 16.1 ... 16.1 ... 15.4 16.3 ... 16.2 ... 15.5 2 ... 8 ... 14 2 ... 8 ... 14 2 ... 8 ... 14 0 ... 7 ... 14 0 ... 7 ... 14 0 ... 7 ... 14 68 > 25 dB Typically: 25 dB > 10 dB 67 > 25 dB Typically: 25 dB > 10 dB 1.0 dB 65 > 25 dB Typically: 25 dB > 10 dB 65 > 25 dB Typically: 18 dB > 10 dB 64 > 25 dB Typically: 19 dB > 10 dB 1.0 dB 60 > 25 dB Typically: 20 dB > 10 dB

9.7 9.3 214, continuously adjustable 2 ... 8 ... 14 T 2 ... 8 ... 14 T 2 ... 8 ... 14 T 17 ... 17 ... 15 dB 17 ... 17 ... 16 dB 17 ... 17 ... 16 dB

10

9 8.7 014, continuously adjustable 0 ... 7 ... 14 T 0 ... 7 ... 14 T 0 ... 7 ... 14 T 18 ... 17 ... 17 dB 18 ... 17 ... 17 dB 18 ... 17 ... 17 dB

9.5

50 < 1.5 > 30 dB > 35 dB (790960 // 17102180 MHz)11 > 30 dB (17102180 // 17102180 MHz) < 153 dBc (2 x 43 dBm carrier) 400 W (at 50 C ambient temperature) 250 W (at 50 C ambient temperature)

790 960 +45/ 45 Polarization


125 65 9.5

1710 2180 45 bottom 1710 2180 45 top 790 960 45

1710 2180 +45 bottom 790 960 +45 1710 2180 +45 top

10 3 0

10

dB

Horizontal Pattern

Vertical Pattern 2 14 electrical downtilt

dB

7-16

7-16

7-16 7-16

7-16

7-16

1710 1990 +45/ 45 Polarization


Subject to alteration.
120 65

Mechanical specifications Input 6 x 7-16 female (long neck) Bottom 3 x, Position bottom continuously adjustable Frontal: Lateral: Rearside: 640 N (at 150 km/h) 400 N (at 150 km/h) 950 N (at 150 km/h) 200 km/h 2058 / 262 / 149 mm M (Medium) 27 kg 2385 x 282 x 182 mm

9.2

Connector position Adjustment mechanism Wind load

10

10

dB

Horizontal Pattern

Vertical Pattern 0 14 electrical downtilt

936.3880/a

1920 2180 +45/ 45 Polarization


115 60 8.7

dB

Max. wind velocity Height/width/depth Category of mounting hardware Weight Packing size

10

10

dB

Horizontal Pattern Internet: www.kathrein.de

Vertical Pattern 0 14 electrical downtilt

dB

80010291V01 Page 1 of 4

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

Accessories General Information


Accessories
Type No. 738546 85010002 85010003 737978 Description 1 clamp 1 clamp 1 clamp Remarks Mast: 50 115 mm diameter Mast: 110 220 mm diameter Mast: 210 380 mm diameter Weight approx. 1.0 kg 2.7 kg 4.8 kg 2.8 kg Units per antenna 2 (order separately if required) 2 (order separately if required) 2 (order separately if required) 1 (order separately if required) 2058 2101 2141 long neck 3542
45 88 106 134 149 171 50 103 180 203 262

72 64 9 Adjustment mechanism with integrated scale Bottom view RCU RCU RCU 45 +45 45 45 +45 +45 17102180
bottom system

1 downtilt kit Downtilt angle: 0 11

For downtilt mounting use the clamps for an appropriate mast diameter together with the downtilt kit. Wall mounting: No additional mounting kit needed. Material: Reflector screen: Weather-proof aluminum. Fiberglass housing: It covers totally the internal antenna components. Fiberglass material guarantees optimum performance with regards to stability, stiffness, UV resistance and painting. The colour of the radome is light grey. All screws and nuts: Stainless steel. The metal parts of the antenna including the mounting kit are DC grounded. The inputs 790 960 MHz and 1710 2180 MHz are also DC grounded.

Grounding:

Environmental conditions: Kathrein cellular antennas are designed to operate under the environmental conditions as described in ETS 300 019-1-4 class 4.1 E. The antennas exceed this standard with regard to the following items: Low temperature: 55 C High temperature (dry): +60 C Ice protection: Due to the very sturdy antenna construction and the protection of the radiating system by the radome, the antenna remains operational even under icy conditions. Environmental tests: Kathrein antennas have passed environmental tests as recommended in ETS 300 019-2-4. The homogenous design of Kathreins antenna families use identical modules and materials. Extensive tests have been performed on typical samples and modules.

790960 17102180 top system Layout of interface

Please note:

The mechanical design is based on the environmental conditions as stipulated in ETS 300 019-1-4 and thereby respects the static mechanical load imposed on an antenna by wind at maximum velocity. Wind loads are calculated according to DIN 1055-4. Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress (e.g. strain caused by oscillating support structures), may result in the breakage of an antenna or even cause it to fall to the ground. These facts must be considered during the site planning process. The installation team must be properly qualified and also be familiar with the relevant national safety regulations. The details given in our data sheets have to be followed carefully when installing the antennas and accessories. The limits for the coupling torque of RF-connectors, recommended by the connector manufacturers must be obeyed. Any previous datasheet issues have now become invalid.

Page 2 of 4 80010291V01

Internet: www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

936.3880/a

Subject to alteration.

As a result of more stringent legal regulations and judgements regarding product liability, we are obliged to point out certain risks that may arise when products are used under extraordinary operating conditions.

General Instructions for Adjustment Mechanism

Description of the adjustment mechanism (protective cap removed):

2 2

Adjustment wheel with twist-lock function. Downtilt spindle with integrated scale.

Thread for fixing the protective cap or the RCU (Remote Control Unit). Gearwheel for RCU power drive.

To set the downtilt angle exactly, you must look horizontally at the scale. The lower edge of the gearwheel must be used for alignment.

Manual adjustment procedure:

0 max.

max. 0

Remove the protective cap.

Set downtilt angle by rotating the adjustment wheel.

Screw on the protective cap again.

Optional: RCU (Remote Control Unit) for remote-controlled downtilt adjustment:


Subject to alteration. 936.3880/a

For a description of RCU installation please refer to the respective data sheet.
Internet: www.kathrein.de

80010291V01 Page 3 of 4

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

General Instructions for Feederline Installation for Triple-band Antennas with Kathrein Installation Set, Type No. 85010005
Please note: To avoid any damage to the interfaces, please ensure that only suitable tools are used. To tighten the feederline connector interfaces, we strongly recommend using a special Kathrein installation tool (as shown below) in combination with a standard torque-wrench.

Description of connector arrangement:

2 1 3

Adjustment mechanisms (1 3)

Feederline connectors (4 9)

There are six feederline connectors and three adjustment mechanisms located at the bottom of the antenna.

Attachment of the feederline connector and RCU (optional):


In order to protect the adjustment mechanism the protective caps have to be attached during feederline installation! Kathrein installation set: Type No. 85010005 Set has to be ordered separately! Set consists of two spanners of 27 and 32 mm width.
1/2 square actuation according to DIN 3120 Form C

The sequence for installation is: feederline no. 4, 5, 6, 7, 8, 9. Put the connector carefully in place and hand-screw the nut. Use a torque-wrench to finish installation (see installation tool). Repeat operations as shown for each feederline!

27 or 32 mm These tools are suitable for 7-16 connectors with a wrench size of 27 or 32 mm. Tighten nut within a torque range of 25 33 Nm depending on connector manufacturers specifications.
Subject to alteration.

After feederline installation, the optional remote control units (RCU) can be mounted if required. For a full description of RCU installation please refer to the respective data sheet.

Please note: Additional weather sealing of correctly installed feederline connector interfaces is not required, nor is it recommended by the connector manufacturers.
Page 4 of 4 80010291V01
Internet: www.kathrein.de

KATHREIN-Werke KG . Anton-Kathrein-Strae 1 3 . P.O. Box 10 04 44 . 83004 Rosenheim . Germany . Phone +49 8031 184-0 . Fax +49 8031 184-973

936.3880/a

Você também pode gostar