Você está na página 1de 12

NetApp FAS3170 System Configuration Data ONTAP 8.0.

1 7-Mode Software

NetApp FAS3170 Memory

Each FAS3170 system module comes standard with onboard NVRAM, which also provides cluster interconnectivity through the chassis backplane. The FAS3170 comes standard with the following types and capacities of memory: Memory capacity Memory type FAS3170 System memory NVRAM7 memory1
1

FAS3170A 32 GB

16 GB

2 GB of DIMM 4 GB of DIMM

The NVRAM7 DIMMs are compatible only with the storage systems that use them. They are incompatible with the adapters and memory for all other storage systems.

Last updated: April 26, 2010

NetApp FAS3170 Disk Shelf Support

The following table lists the supported types of disk storage shelves and disk drives on the FAS3170. Caution: DiskShelf14mk2 AT must not be on the same loop as the Fibre Channel disk shelves. The FAS3170 does not support LRC modules. Note 1: All NetApp HA pair systems now require the use of MPHA cabling with just one exception. (HA pair FAS2040 configurations only have a single SAS port and as such only support single path connectivity to SAS storage shelves.) All NetApp single-controller systems are required to use dual-path connectivity with the exception of the FAS2040 using SAS storage shelves (due to the single SAS data port on the system). Note 2: You can add disk drives of the same type with different capacities within the same disk shelf. However, disk drives must be of the same type (FC, SAS, SSD, or SATA) within a single disk shelf. Standard power Notes supply/optional RPS AC power supply: 110/220V PN: X511A DC power supply: PN: X512A-R5 Two power supplies per shelf required. Fibre Channel DiskShelf14mk2 FC shelves are available in any orderable configurations. Empty shelves: With AC power supplies: PN: X550 Without power supplies: PN: X551 Rack mount kit: PN: X5515A-R6 ESH2 module PN: X5511A Optical SFP PN: X6529 ESH4 module PN: X5512AR5 Optical SFP PN: X6539 FC SFP-to-SFP Patch Cable PN: X6530

Disk shelf

Disk drives

DiskShelf14mk2 FC

144-GB Fibre Channel (PN: X274B-R5/X275BR5/X278A-R5) 300-GB Fibre Channel (PN: X276A/X279A-R5) 450-GB Fibre Channel (PN: X291A-R5) 600-GB Fibre Channel (PN: X292A-R5)
q

Maximum of 14 per shelf

Note: X275, X278, X279, X291, and X292 are 15,000 RPM drives.

Note: When the disk shelf has ESH2s/ESH4s, the maximum number of disk shelves per loop is six and the first shelf in the loop must have optical modules. Note: Systems with more than two loops (112 disks) must also include a system cabinet. DiskShelf14mk4 FC 144-GB Fibre Channel (PN: X274B-R5/X275BR5/X278A-R5) 300-GB Fibre Channel (PN: X276A/X279A-R5) 450-GB Fibre Channel (PN: X291A-R5) 600-GB Fibre Channel (PN: X292A-R5)
q

AC power supply: 110/220V PN: X511A DC power supply: PN: X512A-R5 Two power supplies per shelf required.

Fibre Channel DiskShelf14mk4 FC shelves are available in any orderable configurations. Empty shelves: With AC power supplies: PN: X553A With DC power supplies: PN: X553A-DC Rack mount kit: PN: X5515A-R6 ESH4 module PN: X5512AR5 Optical SFP PN: X6539 FC SFP-to-SFP Patch Cable PN: X6530 Note: The maximum number of disk shelves per loop is six and the first shelf in the loop must have optical modules. Note: Systems with more than two loops (112 disks) must also include a system cabinet.

Maximum of 14 per shelf

Note: X275, X278, X279, X291, and X292 are 15,000 RPM drives.

DS42432, 3, 4 With 24 drives: PN with 300-GB SAS drives: DS4243-1507-24S-QS-R5 PN with 450-GB SAS drives: DS4243-1511-24S-QS-R5 PN with 600-GB SAS drives: DS4243-1514-24S-QS-R5 PN with 100-GB SSD drives: DS4243-SL02-24A-QS-R5 PN with 500-GB SATA drives: DS4243-0712-24A-QS-R5 PN with 1-TB SATA drives: DS4243-0724-24A-QS-R5 PN with 2-TB SATA drives: DS4243-0748-24A-QS-R5 With 12 drives: PN with 300-GB SAS drives: DS4243-1504-12S-QS-R5 PN with 450-GB SAS drives: DS4243-1505-12S-QS-R5 PN with 600-GB SAS drives: DS4243-1507-12S-QS-R5 PN with 500-GB SATA drives: DS4243-0706-12A-QS-R5 PN with 1-TB SATA drives: DS4243-0712-12A-QS-R5 PN with 2-TB SATA drives: DS4243-0724-12A-QS-R5

300-GB SAS (PN: X410A-R5) 450-GB SAS (PN: X411A-R5) 600-GB SAS (PN: X412A-R5) 100-GB SSD (PN: X441A-R5)1, 2, 5 500-GB SATA (PN: X310A-R5) 1-TB SATA (PN: X302AR5) 2-TB SATA (PN: X306AR5)
q

AC power supply: 110/220V PN: X518A-R6

IOM3,SAS,3Gb,DS4243 PN: X5712A-R6 HDD CARR BLANK,EMI,DS4243 PN: X5051-R6 SAS,QSFP-QSFP,CU,100 OHM,0.5M PN: X6557-R6 SAS,QSFP-QSFP,CU,100 OHM,2M PN: X6558-R6 SAS,QSFP-QSFP,CU,100 OHM,5M PN: X6559-R6 SAS,QSFP-QSFP,CU,100 OHM,10M PN: X6590-R6 SAS,QSFP-QSFP,CU,100 OHM,20M PN: X6591-R6 ENETACP,RJ45,CAT6,CU,0.5M PN: X6560-R6 ENETACP,RJ45,CAT6,CU,2M PN: X6561-R6 ENETACP,RJ45,CAT6,CU,5M PN: X6562-R6 ENETACP,RJ45,CAT6,CU,10M PN: X6592-R6 ENETACP,RJ45,CAT6,CU,20M PN: X6593-R6 Note: A maximum of ten DS4243 disk shelves are supported per stack.

Maximum of 24 per shelf

DS22464 With 24 drives: PN with 450-GB SAS drives: DS2246-1011-24S-QS-R5 PN with 600-GB SAS drives: DS2246-1014-24S-QS-R5 With 12 drives: PN with 450-GB SAS drives: DS2246-1005-12S-QS-R5 PN with 600-GB SAS drives: DS2246-1007-12S-QS-R5

450-GB SAS (PN: X421A-R5) 600-GB SAS (PN: X422A-R5)


q

AC power supply: 110/220V PN: X519A-R6

IOM6,SAS,6-Gb,DS2246 PN: X5713A-R6 BLANK,DSK DRV FILLER,DS2246,R6 PN: X5054-R6 SAS,QSFP-QSFP,CU,100 OHM,0.5M PN: X6557-R6 SAS,QSFP-QSFP,CU,100 OHM,2M PN: X6558-R6 SAS,QSFP-QSFP,CU,100 OHM,5M PN: X6559-R6 SAS,QSFP-QSFP,CU,100 OHM,10M PN: X6590-R6 SAS,QSFP-QSFP,CU,100 OHM,20M PN: X6591-R6 ENETACP,RJ45,CAT6,CU,0.5M PN: X6560-R6 ENETACP,RJ45,CAT6,CU,2M PN: X6561-R6 ENETACP,RJ45,CAT6,CU,5M PN: X6562-R6 ENETACP,RJ45,CAT6,CU,10M PN: X6592-R6 ENETACP,RJ45,CAT6,CU,20M PN: X6593-R6 Note: A maximum of ten DS2246 disk shelves are supported per stack.

Maximum of 24 per shelf

DiskShelf14mk2 AT PN with 250-GB drives:DSX3.5TB-R5-C PN with 320-GB drives: DSX4.5TB-R5-C PN with 500-GB drives: DSX7.0TB-R5-C PN with 750-GB drives: DSX10.5TB-R5-C PN with 1-TB drives: DSX14TB-R5-C PN with 2-TB drives: DSX28TB-R5-C

250-GB ATA (PN: X262B-R5) 320-GB ATA (PN: X266B-R5) 500-GB ATA (PN: X267A-R5) 750-GB ATA (PN: X268A-R5) 1-TB ATA (PN: X269AR5) 2-TB ATA (PN: X294AR5)
q

AC power supply: 110/220V PN: X511A DC power supply: PN: X512A-R5 Two power supplies per shelf required.

AT-FCX module PN: X5612A-R5 Rack mount kit: PN: X5515A-R6 Optical SFP PN: X6529 FC SFP-to-SFP Patch Cable PN: X6530 Note: The maximum number of disk shelves per loop is six and the first shelf in the loop must have optical modules.

Maximum of 14 per shelf

1 2 3 4 5

Storage systems using Solid-state disk (SSD) drives require at least one stack of rotating disk drives in addition to the SSD stack. For the disk shelf supporting SSD drives to function properly, a minimum of four SSD drives must be installed in the disk shelf. You can add up to four DS4243 disk shelves populated with SSD drives per storage system. Additional disk shelves of any valid type can be added, provided these disk shelves are populated with rotating disk drives.

These disk shelves are not supported for MetroCluster configurations in the Data ONTAP 8.0.1 release. This drive is supported in Data ONTAP 8.0.1 RC1 and later.

Last updated: August 23, 2011

NetApp FAS3170 System Capacity

The following table lists the maximum system capacity and full system capacity supported by a FAS3170: NOTE: Full system capacity is the resulting system capacity of a storage system when populated with the maximum number of drives of a specific capacity point. This is the achievable system capacity of a storage system when using drives of a specific type and capacity point. Configuration rules common to a single FAS3170 or a FAS3170A in an HA environment

Size

32-bit Maximum raw aggregate/traditional volume size (in TB) 64-bit Minimum root FlexVol volume size (in GB) Maximum provisioned storage limit (in PB)4 Default Using FC drives Maximum RAID4 Using SATA drives Using SSD drives RAID Group Size (in number of disks) Default Using FC drives Maximum RAID-DP Using SATA drives Using SSD drives Default Maximum Default Maximum Default Maximum Default Maximum

16 70 250 2.4 8 14 7 7 8 14 16 28 14 20 23 28

Configuration rules for a single dual-pathed FAS3170, a non multipathed FAS3170A3, and a multipathed FAS3170A3

Size

Maximum system capacity (in TB) Using 600-GB FC drives5 Using 2-TB SATA drives5 Full system capacity1, 2 (in TiB) Using 600-GB SAS drives5 Using 100-GB SSD drives5 Maximum number of drives
1

1680 Up to 448 Up to 1358 Up to 448 Up to 7 840

Full system capacity remains the same for storage systems that use the mirroring functionality. Full system capacity varies depending on the type, size, and number of drives, where type can be FC drives only, SATA drives only, or a mixed storage solution. A mixed storage solution is configured with one loop dedicated to disk shelves that use FC drives and another loop dedicated to disk shelves that use SATA drives. The FAS3170A capacity is the sum of the capacity of both nodes. Do not exceed this sum. This is the maximum provisioned storage limit, including when using thin provisioning. Disk drive capacity listed is the largest shipping disk drive supported on the date of the last update to this page.

3 4 5

Last updated: April 27, 2011

NetApp FAS3170 Expansion Slot Assignments

The FAS3170 has two onboard 10Base-T/100Base-TX/1000Base-T copper interfaces and four auto-sensing 4/2/1-GB loop speed onboard optical Fibre Channel interfaces that can function as initiator-mode interfaces or FCP target-mode interfaces. It also has an internal slot for the required Remote LAN Module (RLM - PN: X3304R5). A FAS3170 in a high-availability (HA) pair has a total of four onboard 10Base-T/100Base-TX/1000Base-T copper interfaces and eight auto-sensing 4/2/1-GB loop speed onboard optical Fibre Channel interfaces that can function as initiator-mode interfaces or FCP target-mode interfaces, and two Remote LAN Modules. The following table lists the types and part numbers of the optional expansion adapters that you can install in the four expansion slots that are available in the FAS3170 system module or in each system module of the FAS3170A. Note: The following table lists the recommended top to bottom load order for adapters into storage systems.

Expansion slot1 Expansion adapter PN Maximum number of adapters 1 2 3 4

Bus B Fabric MetroCluster adapter Dual-port 4/2/1-Gb VI-MetroCluster3 X1926A-R6 1 E1

Bus D

High Performance Network and Block Access adapters Dual-port 10GbE SFP+ with copper or fiber Dual-port optical 10 GbE TOE Dual-port 10-GbE Unified Target Adapter with fiber (supports FCoE/10GbE/iSCSI/NFS/CIFS) Dual-port 10-GbE Unified Target Adapter with copper (supports FCoE/10GbE/iSCSI/NFS/CIFS) Dual-port 8/4/2-Gb FCP target-mode interface X1107A-R66, 8 X1008A-R6 X1139A-R6 X1140A-R6 X1131A-R6 4 E1 E2 E3 E4

Performance Acceleration Module I (PAM I) and Flash Cache modules Performance Acceleration Module I (PAM I) Flash Cache 512 GB X1936A-R57 X1938A-R59 4 E1 2 E2 E3 E4

Disk Shelf Storage adapters Quad-port 4/2/1-Gb Fibre Channel optical Quad-port 3/6-Gb SAS Dual-port 4/2/1-Gb Fibre Channel optical Standard Performance Block Access adapters Quad-port 4/2/1-Gb FCP target-mode interface Dual-port 4-Gb FCP target-mode interface Dual-port copper iSCSI Dual-port optical iSCSI Standard Performance Network adapters Quad-port GbE with copper Quad-port copper GbE TOE Dual-port copper GbE Dual-port optical GbE Dual-port 4/2/1-Gb SnapMirror over Fibre Channel interface Tape Storage adapters Quad-port 4/2/1-Gb Fibre Channel optical Dual-port SCSI-LVD/SE Dual-port 4/2/1-Gb Fibre Channel optical
1 2 3 4

X2054A-R6 /X2054B-R62, 5 X2065A-R66, 10 X2055A-R6 4

E1

E2

E3

E4

E4

E3

E2

E1

X1130A-R6 X1128A-R6 X1129A-R5

4 2 E4 4 E3 E2 E1

X1136A-R5

X1049A-R6 X1006A-R5 4 X1039A-R6 X1038A-R6 X1124A-R64 2 E1 E2 E4 E3 E2 E1

X2054A-R6 /X2054B-R62, 5 X2028A-R6 X2053A-R6 4

E1

E2

E3

E4

E4
The numbers on the side of the "X" or the "E" indicate the preferred order of slot assignment and configuration. See the documentation that comes with this adapter or with the storage controller for rules of usage. Only these storage adapters are supported in a Fabric MetroCluster configuration.

E3

E2

E1

Source and destination systems do not need to have the same SnapMirror over Fibre Channel (SMoFC) card type. While only the X1124 is supported on this platform, if the source or destination controller is a different platform supporting X1024, X1124, or X1142 SMoFC cards those may be used for connecting to the X1124 on this platform. This adapter cannot be used in a Fabric MetroCluster configuration. However, it can be used in a Stretch MetroCluster configuration. This adapter is supported in Data ONTAP 8.0 RC3 and later. PAM I and Flash Cache modules are not supported together in the same chassis. This adapter requires the SFP+ PN X6563-R6 or a twinax cable for connectivity. Flash Cache was previously known as PAM II. Total Flash Cache may not exceed 1.0 TB. Cannot coexist with PAM I.

6 7 8 9

10

Revision B1 of this adapter is not supported in slot 4; the maximum number of revision B1 adapters allowed is 3.

Last updated: August 29, 2011