szv6x1@usplsmedp082 # prtdiag -v

System Configuration: Sun Microsystems sun4u Sun Fire V440


System clock frequency: 177 MHZ
Memory size: 16GB
==================================== CPUs ====================================
E$
CPU
CPU
Temperature
CPU Freq
Size
Implementation
Mask
Die Amb. Status
Location
--- -------- ---------- --------------------- ----- ---- ---- ------------0
1593 MHz 1MB
SUNW,UltraSPARC-IIIi
3.4
online
1
1593 MHz 1MB
SUNW,UltraSPARC-IIIi
3.4
online
2
1593 MHz 1MB
SUNW,UltraSPARC-IIIi
3.4
online
3
1593 MHz 1MB
SUNW,UltraSPARC-IIIi
3.4
online
================================= IO Devices =================================
Bus
Freq Slot +
Name +
Type
MHz Status
Path
Model
------ ---- ---------- ---------------------------- -------------------pci
66
MB
pci108e,abba (network)
SUNW,pci-ce
okay
/pci@1c,600000/network@2
pci

66

PCI5
okay

pci100b,35 (network)
SUNW,pci-ce
/pci@1c,600000/pci@1/network@0

pci

66

PCI5
okay

pci100b,35 (network)
SUNW,pci-ce
/pci@1c,600000/pci@1/network@1

pci

66

PCI5
okay

scsi-pci1000,b (scsi-2)
/pci@1c,600000/pci@1/scsi@2

pci

66

PCI5
okay

scsi-pci1000,b (scsi-2)
/pci@1c,600000/pci@1/scsi@2,1

pci

33

MB
okay

isa/su (serial)
/pci@1e,600000/isa@7/serial@0,3f8

pci

33

MB
okay

isa/su (serial)
/pci@1e,600000/isa@7/serial@0,2e8

pci

33

MB
okay

isa/rmc-comm-rmc_comm (seria+
/pci@1e,600000/isa@7/rmc-comm@0,3e8

pci

33

MB
okay

pciclass,0c0310 (usb)
/pci@1e,600000/usb@a

pci

33

MB
okay

pciclass,0c0310 (usb)
/pci@1e,600000/usb@b

pci

33

MB
okay

pci10b9,5229 (ide)
/pci@1e,600000/ide@d

pci

66

MB
okay

pci108e,abba (network)
/pci@1f,700000/network@1

SUNW,pci-ce

pci

66

MB
okay

scsi-pci1000,30 (scsi-2)
/pci@1f,700000/scsi@2

LSI,1030

pci

66

MB
okay

scsi-pci1000,30 (scsi-2)
/pci@1f,700000/scsi@2,1

LSI,1030

============================ Memory Configuration ============================


Segment Table:
----------------------------------------------------------------------Base Address
Size
Interleave Factor Contains
----------------------------------------------------------------------0x0
4GB
16
BankIDs 0,1,2,3,4,5,6,7,8,9,10,
11,12,13,14,15
0x1000000000
4GB
16
BankIDs 16,17,18,19,20,21,22,23
,24,25,26,27,28,29,30,31
0x2000000000
4GB
16
BankIDs 32,33,34,35,36,37,38,39
,40,41,42,43,44,45,46,47
0x3000000000
4GB
16
BankIDs 48,49,50,51,52,53,54,55
,56,57,58,59,60,61,62,63
Bank Table:
----------------------------------------------------------Physical Location
ID
ControllerID GroupID Size
Interleave Way
----------------------------------------------------------0
0
0
256MB
0,1,2,3,4,5,6,7,8,9,10,11,12,13
,14,15
1
0
0
256MB
2
0
1
256MB
3
0
1
256MB
4
0
0
256MB
5
0
0
256MB
6
0
1
256MB
7
0
1
256MB
8
0
1
256MB
9
0
1
256MB
10
0
0
256MB
11
0
0
256MB
12
0
1
256MB
13
0
1
256MB
14
0
0
256MB
15
0
0
256MB
16
1
0
256MB
0,1,2,3,4,5,6,7,8,9,10,11,12,13
,14,15
17
1
0
256MB
18
1
1
256MB
19
1
1
256MB
20
1
0
256MB
21
1
0
256MB
22
1
1
256MB
23
1
1
256MB
24
1
1
256MB
25
1
1
256MB
26
1
0
256MB
27
1
0
256MB
28
1
1
256MB
29
1
1
256MB
30
1
0
256MB
31
1
0
256MB

32
,14,15
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
,14,15
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63

256MB

0,1,2,3,4,5,6,7,8,9,10,11,12,13

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3

0
1
1
0
0
1
1
1
1
0
0
1
1
0
0
0

256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB

0,1,2,3,4,5,6,7,8,9,10,11,12,13

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

0
1
1
0
0
1
1
1
1
0
0
1
1
0
0

256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB
256MB

Memory Module Groups:


-------------------------------------------------ControllerID GroupID Labels
Status
-------------------------------------------------0
0
C0/P0/B0/D0
0
0
C0/P0/B0/D1
0
1
C0/P0/B1/D0
0
1
C0/P0/B1/D1
1
0
C1/P0/B0/D0
1
0
C1/P0/B0/D1
1
1
C1/P0/B1/D0
1
1
C1/P0/B1/D1
2
0
C2/P0/B0/D0
2
0
C2/P0/B0/D1
2
1
C2/P0/B1/D0
2
1
C2/P0/B1/D1
3
0
C3/P0/B0/D0
3
0
C3/P0/B0/D1
3
1
C3/P0/B1/D0
3
1
C3/P0/B1/D1
============================ Environmental Status ============================
Fan Speeds:
--------------------------------------------------Location
Sensor
Status Speed

--------------------------------------------------FT0/F0
TACH
okay
3970 rpm
FT1/F0
TACH
okay
3901 rpm
FT1/F1
TACH
okay
3857 rpm
PS1
FF_PDCT_FAN
okay
PS0
FF_PDCT_FAN
okay
Temperature sensors:
-------------------------------------------------------------------------------Location
Sensor
Temperature Lo LoWarn HiWarn Hi Status
-------------------------------------------------------------------------------C0/P0
T_CORE
78C
-10C
0C
108C
113C okay
C1/P0
T_CORE
75C
-10C
0C
108C
113C okay
C2/P0
T_CORE
78C
-10C
0C
108C
113C okay
C3/P0
T_CORE
77C
-10C
0C
108C
113C okay
C0
T_AMB
26C
-10C
0C
60C
65C okay
C1
T_AMB
24C
-10C
0C
60C
65C okay
C2
T_AMB
26C
-10C
0C
60C
65C okay
C3
T_AMB
26C
-10C
0C
60C
65C okay
SCSIBP
T_AMB
21C
-11C
0C
47C
52C okay
MB
T_AMB
28C
-10C
0C
65C
75C okay
-------------------------------------------------------------------------------Current sensors:
-------------------------------------------------------------------------------Location
Sensor
Current
Lo
LoWarn HiWarn Hi Status
-------------------------------------------------------------------------------MB
FF_SCSIA
- okay
MB
FF_SCSIB
- okay
MB
FF_POK
- okay
C0/P0
FF_POK
- okay
C1/P0
FF_POK
- okay
C2/P0
FF_POK
- okay
C3/P0
FF_POK
- okay
---------------------------------------------------------------------------Voltage sensors:
---------------------------------------------------------------------------Location
Sensor
Voltage
Lo
LoWarn HiWarn Hi
Status
---------------------------------------------------------------------------MB
V_+1V5
1.49V
1.20V 1.27V 1.73V 1.80V okay
MB
V_VCCTM
2.53V
2.00V 2.12V 2.88V 3.00V okay
MB
V_NET0_1V2D
1.25V
0.96V 1.02V 1.38V 1.44V okay
MB
V_NET1_1V2D
1.26V
0.96V 1.02V 1.38V 1.44V okay
MB
V_NET0_1V2A
1.25V
0.96V 1.02V 1.38V 1.44V okay
MB
V_NET1_1V2A
1.27V
0.96V 1.02V 1.38V 1.44V okay
MB
V_+3V3
3.38V
2.64V 2.81V 3.80V 3.96V okay
MB
V_+3V3STBY
3.33V
2.64V 2.81V 3.80V 3.96V okay
MB/BAT
V_BAT
3.02V
2.25V
- okay
MB
V_SCSI_CORE
1.79V
1.44V 1.53V 2.07V 2.16V okay
MB
V_+5V
5.05V
4.00V 4.25V 5.75V 6.00V okay
MB
V_+12V
12.69V
9.60V 10.20V 13.80V 14.40V okay
MB
V_-12V
-11.82V -14.40V -13.80V -10.20V -9.60V okay
PS1
P_PWR
- okay
PS1
FF_POK
- okay
PS0
P_PWR
- okay
PS0
FF_POK
- okay
--------------------Keyswitch:
--------------------Location
State
---------------------

SYS/SYSCTRL
NORMAL
------------------------------------------------------------Led State:
------------------------------------------------------------Location
Led
State
Color
------------------------------------------------------------SYS
ACT
on
green
SYS
SERVICE
off
amber
SYS
LOCATE
off
white
PS1
POK
on
green
PS1
STBY
on
green
PS1
SERVICE
off
amber
PS1
OK2RM
off
blue
HDD0
SERVICE
off
amber
HDD0
OK2RM
off
blue
HDD1
SERVICE
off
amber
HDD1
OK2RM
off
blue
HDD2
SERVICE
off
amber
HDD2
OK2RM
off
blue
HDD3
SERVICE
off
amber
HDD3
OK2RM
off
blue
PS0
POK
on
green
PS0
STBY
on
green
PS0
SERVICE
off
amber
PS0
OK2RM
off
blue
=========================== FRU Operational Status ===========================
--------------------------------Fru Operational Status:
--------------------------------Location
Status
--------------------------------SC
okay
HDD0
present
HDD1
present
HDD2
present
HDD3
present
PS0
okay
PS1
okay
================================ HW Revisions ================================
ASIC Revisions:
------------------------------------------------------------------Path
Device
Status
Revision
------------------------------------------------------------------/pci@1c,600000
pci108e,a801
okay
4
/pci@1d,700000
pci108e,a801
okay
4
/pci@1e,600000
pci108e,a801
okay
4
/pci@1f,700000
pci108e,a801
okay
4
System PROM revisions:
---------------------OBP 4.22.33 2007/06/18 12:42 Sun Fire V440,Netra 440
OBDIAG 4.22.33 2007/06/18 12:57
szv6x1@usplsmedp082 # cat /var/adm/messages
Jan 20 14:48:04 usplsmedp082 sendmail[22233]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 20 14:49:04 usplsmedp082 sendmail[22233]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 20 22:00:00 usplsmedp082 sendmail[1354]: [ID 702911 mail.crit] My unqualifie

d host name (usplsmedp082) unknown; sleeping for retry


Jan 20 22:01:00 usplsmedp082 sendmail[1354]: [ID 702911 mail.alert] unable to qu
alify my own domain name (usplsmedp082) -- using short name
Jan 20 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 20 23:20:00 usplsmedp082 last message repeated 4 times
Jan 20 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM A
CCOUNTING STARTED Fri Jan 20 23:20:00 CST 2012 **********
Jan 20 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 20 23:20:00 usplsmedp082 last message repeated 4 times
Jan 20 23:20:00 usplsmedp082 adm: [ID 702911 daemon.error]
Jan 20 23:20:00 usplsmedp082 last message repeated 1 time
Jan 20 23:20:00 usplsmedp082 adm: [ID 702911 daemon.error] ************ ACCT ERR
ORS : see /var/adm/acct/nite/active0120********
Jan 20 23:20:00 usplsmedp082 adm: [ID 702911 daemon.error]
Jan 20 23:20:00 usplsmedp082 last message repeated 1 time
Jan 20 23:20:00 usplsmedp082 sendmail[9166]: [ID 702911 mail.crit] My unqualifie
d host name (usplsmedp082) unknown; sleeping for retry
Jan 20 23:20:02 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM AC
COUNTING COMPLETED Fri Jan 20 23:20:02 CST 2012 **********
Jan 20 23:21:00 usplsmedp082 sendmail[9166]: [ID 702911 mail.alert] unable to qu
alify my own domain name (usplsmedp082) -- using short name
Jan 21 14:51:48 usplsmedp082 sendmail[3828]: [ID 702911 mail.crit] My unqualifie
d host name (usplsmedp082) unknown; sleeping for retry
Jan 21 14:52:48 usplsmedp082 sendmail[3828]: [ID 702911 mail.alert] unable to qu
alify my own domain name (usplsmedp082) -- using short name
Jan 21 22:00:00 usplsmedp082 sendmail[12538]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 21 22:01:00 usplsmedp082 sendmail[12538]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 21 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 21 23:20:00 usplsmedp082 last message repeated 4 times
Jan 21 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM A
CCOUNTING STARTED Sat Jan 21 23:20:00 CST 2012 **********
Jan 21 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 21 23:20:00 usplsmedp082 last message repeated 4 times
Jan 21 23:20:02 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM AC
COUNTING COMPLETED Sat Jan 21 23:20:02 CST 2012 **********
Jan 22 02:15:01 usplsmedp082 explorer: [ID 702911 daemon.notice] Explorer starte
d
Jan 22 02:16:15 usplsmedp082 explorer: [ID 702911 daemon.notice] Explorer finish
ed
Jan 22 02:16:15 usplsmedp082 sendmail[14342]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 22 02:17:15 usplsmedp082 sendmail[14342]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 22 14:46:58 usplsmedp082 sendmail[21692]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 22 14:47:58 usplsmedp082 sendmail[21692]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 22 15:00:14 usplsmedp082 sendmail[23035]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 22 15:01:14 usplsmedp082 sendmail[23035]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 22 22:00:00 usplsmedp082 sendmail[560]: [ID 702911 mail.crit] My unqualified
host name (usplsmedp082) unknown; sleeping for retry
Jan 22 22:01:00 usplsmedp082 sendmail[560]: [ID 702911 mail.alert] unable to qua
lify my own domain name (usplsmedp082) -- using short name
Jan 22 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 22 23:20:00 usplsmedp082 last message repeated 4 times
Jan 22 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM A

CCOUNTING STARTED Sun Jan 22 23:20:00 CST 2012 **********


Jan 22 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 22 23:20:00 usplsmedp082 last message repeated 4 times
Jan 22 23:20:01 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM AC
COUNTING COMPLETED Sun Jan 22 23:20:01 CST 2012 **********
Jan 23 14:46:45 usplsmedp082 sendmail[2630]: [ID 702911 mail.crit] My unqualifie
d host name (usplsmedp082) unknown; sleeping for retry
Jan 23 14:47:45 usplsmedp082 sendmail[2630]: [ID 702911 mail.alert] unable to qu
alify my own domain name (usplsmedp082) -- using short name
Jan 23 21:41:12 usplsmedp082 rmclomv: [ID 512354 kern.error] Input power unavail
able for PSU @ PS0.
Jan 23 21:43:20 usplsmedp082 last message repeated 1 time
Jan 23 21:43:31 usplsmedp082 rmclomv: [ID 838909 kern.error] FAULT_SENSOR @ PS0.
FF_POK has faulted. May be caused by MB POK circuitry malfunction.
Jan 23 22:00:00 usplsmedp082 sendmail[11843]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 23 22:01:00 usplsmedp082 sendmail[11843]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 23 23:05:04 usplsmedp082 automountd[227]: [ID 784820 daemon.error] server p0
62m not responding
Jan 23 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 23 23:20:00 usplsmedp082 last message repeated 4 times
Jan 23 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM A
CCOUNTING STARTED Mon Jan 23 23:20:00 CST 2012 **********
Jan 23 23:20:00 usplsmedp082 adm: [ID 702911 daemon.notice]
Jan 23 23:20:00 usplsmedp082 last message repeated 4 times
Jan 23 23:20:01 usplsmedp082 adm: [ID 702911 daemon.error]
Jan 23 23:20:01 usplsmedp082 last message repeated 1 time
Jan 23 23:20:01 usplsmedp082 adm: [ID 702911 daemon.error] ************ ACCT ERR
ORS : see /var/adm/acct/nite/active0123********
Jan 23 23:20:01 usplsmedp082 adm: [ID 702911 daemon.error]
Jan 23 23:20:01 usplsmedp082 last message repeated 1 time
Jan 23 23:20:01 usplsmedp082 sendmail[19921]: [ID 702911 mail.crit] My unqualifi
ed host name (usplsmedp082) unknown; sleeping for retry
Jan 23 23:20:02 usplsmedp082 adm: [ID 702911 daemon.notice] ********** SYSTEM AC
COUNTING COMPLETED Mon Jan 23 23:20:02 CST 2012 **********
Jan 23 23:21:01 usplsmedp082 sendmail[19921]: [ID 702911 mail.alert] unable to q
ualify my own domain name (usplsmedp082) -- using short name
Jan 24 05:09:14 usplsmedp082 explorer: [ID 702911 daemon.notice] Explorer starte
d
Jan 24 05:10:26 usplsmedp082 explorer: [ID 702911 daemon.notice] Explorer finish
ed
szv6x1@usplsmedp082 #